DATA SHEET
Ametherm, Inc
. 3111 N. Deer Run Road #4 Carson City, NV 89701
Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670
www.ametherm.com
Part Number: NT05 10052
Ordering Different Lead Types:
For example: to order an inside kinked lead use part number NT05 10052
-A
Electrical
Specifications:
Mechanical
Specifications:
Resistance Temperature Curve:
Revision Date: March 19, 2003
Inside Kinked Leads
Use
-A
after Ametherm’s part #
Outside Kinked Leads
Not Available
Zero-Power Resistance @ 25°C
10.0
Ω
±
10%
Resistance @ 0°C/ Resistance @ 50°C
5.1
±
2%
Resistance @ 25°C/ Resistance @ 125°C
12.9
±
2%
Beta
2980
±
2%
Temp Coefficient of Resistance @ 25°C
-3.19%/°C
Operating Temperature Range
-50°C/150°C
Dissipation Constant
5.0mW/°C
Thermal Time Constant
10.0 Seconds
D
5.6 mm Max
T
3.0 mm Max
Lead Diameter
0.5 mm Nom
S
2.5 mm Nom
L
38.0 mm Min
Straight Leads
Standard
Temperature
R@T/R@25
°
C
-50 24.23
-40 14.36
-30 8.90
-20 5.65
-10 3.62
Temperature
R@T/R@25
°
C
0 2.42
25 1.000
50 0.465
75 0.240
100 0.138
125 0.0801
L
OUTSIDE
KINKED LEADS
S
STRAIGHT
LEADS
B
INSIDE
KINKED LEADS
S
S
D
D
D
C
T