background image

                         

 

DATA SHEET

 

Ametherm, Inc

.  3111 N. Deer Run Road #4 Carson City, NV  89701 

Telephone: (800) 808-2434   (775) 884-2434     Fax:  (775) 884-0670

 

www.ametherm.com 

 

Part Number: NT05 10052

 

 

Ordering Different Lead Types:

 

 

 
 

For example: to order an inside kinked lead use part number NT05 10052

-A

 

 

 

     

 
 

 

 
 
 

 
 
 
 

 

Electrical 

Specifications: 

      

 

Mechanical 

Specifications: 

 
 

Resistance Temperature Curve:

 

 

 

 
 
 
 
 
 

 

 

Revision Date: March 19, 2003 

Inside Kinked Leads 

Use 

-A

 after Ametherm’s part # 

Outside Kinked Leads 

Not Available 

Zero-Power Resistance @ 25°C 

10.0 

 

±

 10% 

Resistance @ 0°C/ Resistance @ 50°C 

5.1 

±

 2% 

Resistance @ 25°C/ Resistance @ 125°C 

12.9 

±

 2% 

Beta 

2980 

±

 2% 

Temp Coefficient of Resistance @ 25°C 

-3.19%/°C 

Operating Temperature Range 

-50°C/150°C 

Dissipation Constant 

5.0mW/°C 

Thermal Time Constant 

10.0 Seconds 

5.6 mm Max 

3.0 mm Max 

Lead Diameter 

0.5 mm Nom 

2.5 mm Nom 

38.0 mm Min 

Straight Leads  

Standard 

Temperature 

R@T/R@25

°

-50 24.23 
-40 14.36 
-30 8.90 
-20 5.65 
-10 3.62 

Temperature 

R@T/R@25

°

0 2.42 

25 1.000 
50 0.465 
75 0.240 

100 0.138 
125 0.0801 

L

OUTSIDE

KINKED LEADS

S

STRAIGHT

LEADS

B

INSIDE

KINKED LEADS

S

S

D

D

D

C

T