background image

Bussmann electrical full line catalog

Leadership in Circuit  
Protection

 

Introducing Bussmann by Eaton

The protection you rely on. For more, visit Bussmann.com

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Leadership in Circuit Protection.

The only company

The Eaton advantage.

Powering business worldwide

As a global diversified power management company, we 
help customers worldwide manage the power needed for 
buildings, aircraft, trucks, cars, machinery and businesses.

Eaton’s innovative technologies help customers manage 
electrical, hydraulic and mechanical power more reliably, 
efficiently, safely and sustainably.

We provide integrated solutions that help make energy, 
in all its forms, more practical and accessible.

With 2012 sales of $16.3 billion, Eaton has approximately 
103,000 employees around the world and sells products 
in more than 175 countries. 

Eaton.com

O

n

l

y

 Ea

t

o

n

 ca

n

 del

i

ve

r

...

• 

 The most diverse solutions to mitigate arc flash energy to keep people and equipment safe 

• 

 The smallest and most cost effective way to meet selective coordination requirements 

• 

 The most experienced, time-tested solutions to meet national & local code requirements 

• 

 The easiest specifications with the most tested fuse/circuit breaker and circuit breaker/circuit breaker 
 series rated combinations

• 

 The only one-stop shop to solve your design challenges using our expertise and an unmatched portfolio 

that can provide a complete circuit 
protection solution for all applications.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

3

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

Introducing Fuses Made Simple

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

4

Alternative Energy Vertical Market

A Complete Line of

Circuit

Protection Solutions

for the

Alternative Energy Markets

60

Ferrule

Photovoltaic

Fuses

56

PVM Midget

& PV Fuses

59

PVS-R RK5

PV Fuses

57

CUBEFuse™

PVCF & WCF

121

Square Body,

BS and UL

High Speed Fuses

63

XL Photovoltaic

Fuses and Blocks

442

Surge Protection

Solutions 

Photovoltaic and Wind

270

Safety Switches

AC & DC

274

Modular Fuse

Holders

325

Power

Distribution 

Blocks

289

Modular

Knifeblade

Fuse Blocks

266

Quik-Spec™

Coordination

Panelboard

62

NH Fuses & 

Fuse Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

5

Data Centers Vertical Market

A Complete Line of

Circuit

Protection Solutions

for

Data Centers

23

Low-Peak™

CC Fuses

380

Compact Circuit

Protectors

333

DIN-Rail Terminal

Blocks and

Connectors

125

DFJ

High Speed

Fuses

266

Quik-Spec™

Coordination

Panelboard

121

Square Body,

BS and UL

High Speed Fuses

441

Surge Protection

Solutions 

– UL, IEC and LV

28

CUBEFuse™

TCF & FCF

325

Power

Distribution 

Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

6

Oil & Gas/ Mining Vertical Market

A Complete Line of

Circuit

Protection Solutions

for

Oil & Gas / Mining

26

CUBEFuse™

TCF & FCF

46

Fusetron™ Energy

Efficient Fuses

23

Low-Peak™

Fuses

380

Compact Circuit

Protectors

327

Power

Distribution 

Blocks

99

Medium

Voltage Fuses

121

Square Body,

BS and UL

High Speed Fuses

441

Surge Protection

Solutions 

– UL, IEC and LV

274

Modular Fuse

Holders

62

NH Fuses & 

Fuse Blocks

289

Modular

Knifeblade

Fuse Blocks

125

DFJ

High Speed

Fuses

266

Quik-Spec™

Coordination

Panelboard

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

7

Circuit Protection Products for the Electrical Industry

Table of Contents

Bussmann circuit protection solutions comply with major industrial standards and agency requirements such as: BS, IEC, DIN, UL, NEMA, CSA, CE, C-UL, etc. and are manufactured at facilities that are ISO 9000 certified.

This catalog is intended to present product data and provide technical information that will help the end user with design application. Bussmann reserves the right, without notice, to change design or construction or any products
and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this catalog. Once a product has been selected, it should be
tested by the user in all possible applications. Further, Bussmann takes no responsibility for errors or omissions contained in this catalog, or for mis-application of any Bussmann product. Extensive product information is available
in the Bussmann product data sheets available on line at 

www.cooperbussmann.com/DatasheetsEle

.

©2013 Bussmann

RED 

indicates

NEW 

information

Vertical Market Product Pages  . . . . . . . . . . . . .4-6

Alternative energy  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Data centers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Oil & gas / mining  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Peel and Stick Tabs  . . . . . . . . . . . . . . . . . . . . . .11

Selecting Circuit Protection . . . . . . . . . . . . . .12-16

2011 NEC

®

guide to fuse selection for various 

applications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-16

Low Voltage, Branch Circuit Rated Fuses  . . .17-52

Holders & blocks for branch circuit rated fuses  . . . . . . .18-20
Dimensions data for branch circuit rated fuses  . . . . . . .21-22

Class CC

LP-CC Low-Peak  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
FNQ-R CC-Tron  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
KTK-R Limitron  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

Class CF

TCF, 

FCF & WCF CUBEFuse  . . . . . . . . . . . . . . . . . . . . .26-31

CUBEFuse finger-safe holder system  . . . . . . . . . . . . . . .32-33

Class G

SC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34

Class J

LPJ-_SP & LPJ-_SPI Low-Peak  . . . . . . . . . . . . . . . . . . . . .35
JKS Limitron  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

Class K5 & H

NON (250V) & NOS (600V) One time   . . . . . . . . . . . . . . . . .37

Class L

KRP-C_SP Low-Peak  . . . . . . . . . . . . . . . . . . . . . . . . . .38-39
KRP-CL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
KTU & KLU Limitron  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40

Class RK1

LPN-RK_SP & LPN-RK_SPI (250V) Low-Peak  . . . . . . . .41-43
LPS-RK_SP & LPS-RK_SPI (600V) Low-Peak  . . . . . . . .41-43
KTN-R (250V) Limitron . . . . . . . . . . . . . . . . . . . . . . . . . . . .44

KTS-R (600V) Limitron  . . . . . . . . . . . . . . . . . . . . . . . . . . . .45

Class RK5

FRN-R (250V) Fusetron (Energy Efficient)  . . . . . . . . . . . . . .46
FRS-R (600V) Fusetron (Energy Efficient)  . . . . . . . . . . . . . .47

Class T

JJN (300V) T-Tron  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
JJS (600V) T-Tron  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49

Edison & Rejection Base Plug Fuses

Plug Fuses (S, SL, T, TL & W)  . . . . . . . . . . . . . . . . . . . .50-51
MB Edison Base Circuit Breakers  . . . . . . . . . . . . . . . . . . . .52
SA Rejection-base plug fuse adapters  . . . . . . . . . . . . . . . .52

Solar Fuse Products  . . . . . . . . . . . . . . . . . . .53-70

PVM (600Vdc)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
PVCF (600Vac/300Vdc)  . . . . . . . . . . . . . . . . . . . . . . . .57-58
PVS-R (600Vac/dc)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
PV (1000Vdc) 10x38mm  . . . . . . . . . . . . . . . . . . . . . . . . . .60
PV (1000/1100Vdc) 14x51mm  . . . . . . . . . . . . . . . . . . . . .61
NH1 (1000Vdc)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
XL PV (1000Vdc) XL Size 01, 1, 2, 3  . . . . . . . . . . . . . . .63-65
PV (1300/1500Vdc) 14x65mm  . . . . . . . . . . . . . . . . . . . . .66
XL PV (1200/1500Vdc) XL Size 01, 1, 2, 3  . . . . . . . . . .67-69

Low Voltage Supplementary Fuses  . . . . . . . .71-84

Holders & blocks for supplemental fuses  . . . . . . . . . . . .72-73
Cable (K Series) & Welder (64000/68000 Series) Limiters  . .74

13

32

" x 1 

1

2

" fast-acting fuses BAF, KTK & KLM . . . . . . . . . . .75

13

32

" x 1 

1

2

" time-delay fuses FNM & FNQ  . . . . . . . . . . . . . .76

13

32

" x 1 

3

8

" fast-acting fuses BBS  . . . . . . . . . . . . . . . . . . . .77

Pin indication fuses GBA/GLD, MIC & MIN, FNA, 

MIS & KAZ  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78-79

Limiters & blocks ANL & ANN . . . . . . . . . . . . . . . . . . . . . . .79
In-line size rejecting fuses and holders GLQ, GMQ, HLQ  . . .80
In-line non-rejecting fuses and holders GLR, GMF, GRF, 

HLQ  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81

Automotive blade fuses and holders ATM, ATC, MAX  . . .82-83
Automotive PCB fuse clips for ATM & ATC . . . . . . . . . . . . . .84

Electronic - PC Board and Small Dimension 

Fuses  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85-98

5 x 15mm Ferrule fuses C515, C516, C517, C518, 

C519, C520  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86

5 x 20mm European (IEC) fuses 

S500, S501, S505, S506, GDA, GDB, GDC  . . . . . . . .87-88

5 x 20mm North American (UL) fuses GMA, GMC, 

GMD-  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89

1

4

" Diameter x 

5

8

" to 1" length ferrule fuses AGA, 

AGW, AGX  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90

1

4

" Diameter x 1 

1

4

" length fast-acting ferrule fuses ABC, 

AGC, GBB  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91

1

4

" Diameter x 1 

1

4

" length time-delay ferrule fuses MDA, 

MDL, MDQ  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92

PC Board mount fuse holders HTC-, HBH-, HBV-, HBW-, 

FBI, FBM  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93-94

PC Board fuseclips HTC-_M, 1A_, 56_  . . . . . . . . . . . . .95-98

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

8

Circuit Protection Products for the Electrical Industry

Table of Contents

RED 

indicates

NEW 

information

Medium Voltage Fuses  . . . . . . . . . . . . . . . .99-120

Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
E-Rated fuses for transformers & feeders  . . . . . . . . .101-104

E-Rated fuses: CL-14 & bolt-in  . . . . . . . . . . . . . . . . .105-107

E-Rated fuses for potential & small power 

transformers  . . . . . . . . . . . . . . . . . . . . . . . . . . . .108-110

Potential transformer fuses  . . . . . . . . . . . . . . . . . . . . . . .111
R-Rated fuses for motor circuit protection  . . . . . . . . .112-114
British Standard IEC fuses for motor circuit protection   . . .115
DIN IEC fuses for transformers  . . . . . . . . . . . . . . . . . . . . .116

Expuision Fuse Links  . . . . . . . . . . . . . . . . . . . . . . . .117-118

EEI-NEMA Type K & T, and Type H & N fuses . . . . . . . . . . .119
Fuseclips for medium voltage fuses  . . . . . . . . . . . . . . . . .120

High Speed Semiconductor Fuses  . . . . . .121-244

General Applications . . . . . . . . . . . . . . . . . . . . . . . . .122-123
North American fuses and accessories 

DFJ, FWA, FWH, FWJ, FWP, FWX, KAC, KBC,   . . . .124-141

Square body fuses and accessories 

DIN 43 620, DIN 43 653, flush-end contact, French Style, 
US Style 170E, 170F, 170H, 170M  . . . . . . . . . . . .142-213

British BS 88 fuses and accessories

CT, ET, EET, FE, FEE, FM, FMM, LCT, LET, LMMT, LMT, 
MMT, MT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214-222

Ferrule fuses and accessories 

FWA, FWC, FWH, FWJ, FWK, FWL, FWP, FWS, 
FWX  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223-244

IEC & British Standard Fuses  . . . . . . . . . .245-264

Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . .245-246
CSA Type P and Type D fuses CDN, CDS, PON  . . . . . . . . .247
HRC Form II Class C Tron

fuses CGL . . . . . . . . . . . . . . . .248

HRCI Industrial ceramic body fuses CIF . . . . . . . . . . . . . . .249
HRCI-J Fast-acting fuses CJ  . . . . . . . . . . . . . . . . . . . . . .250
MRCI-Miscellaneous Type K fuses CIH, CIK, CIL . . . . . . . . .251
HRC Form II Current-limiting fuses H07C, K07C, L09C, 

L14C, M09C, M14C, P09C, P11C, R11C  . . . . . . . . . . .252

BS 88 British Standard low voltage fuses AAO, AC, AD, 

BAO, BC, BD, CD, CEO, DD, DEO, ED, EF, EFS, ESD, FF, 
FG, GF, GG, GH, NITD, NSD, OSD, SSD, STD . . . . . .253-254

DIN Type D and Neozed low voltage fuses D16, D27, D33, 

D125, NZ  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255

NH HRC Fuse links & bases NHG  . . . . . . . . . . . . . . .256-259
Class gG/gL IEC 60 269 fuses C08G, C08M, C10G, C10M, 

C14G, C14M, C22G, C22M  . . . . . . . . . . . . . . . . .260-262

HRC Fuse holders CAMaster, SAFEloc . . . . . . . . . . . . . . . .263

Quik-Spec™ Electrical Gear  . . . . . . . . . . .265-272

Quik-Spec™ Coordination Panelboards . . . . . . . . . . .266-267
Quik-Spec™ Power Module™ Elevator Disconnect 

Switches & Panels PS, PMP  . . . . . . . . . . . . . . . . .268-269

Quik-Spec™ DC Safety Switches BD  . . . . . . . . . . . . . . . .270
Quik-Spec™ AC Safety Switches CF  . . . . . . . . . . . . . . . .271
HVAC Disconnects B221, B222  . . . . . . . . . . . . . . . . . . . .272

Fuse Holders and Blocks . . . . . . . . . . . . . .273-322

CH Series global modular fuse holders - Class CC, midget & metric 

CHCC, CHPV, CHM, CH08, CH14, CH22 . . . . . . . . .274-277

Remote fuse monitoring - CH-PLCCH  . . . . . . . . . . . . . . . .278
Comb-bus bar specifications and selection guide  . . . . . . .279
Comb-bus bar features and installation guide  . . . . . . . . . .280

CH Series Class J global modular fuse holders CH  . . . . . .281
Optima - fuse holder module and disconnect switch  . . . . .282
Optima fuse holder module  . . . . . . . . . . . . . . . . . . . . . . .283
Optima NG 3-pole overcurrent protection module . . . .284-285
Safety J Class J (finger-safe) fuse holder JT, JTN . . . .286-287
SAMI™ fuse covers SAMI  . . . . . . . . . . . . . . . . . . . . . . . .288

Modular Knifeblade Fuse Holders  . . . . . . . . . . . . . . .289-290

Class R, H(K), 250 & 600V  . . . . . . . . . . . . . . . . . .291-292
Class J, 600V  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .293

Class H(K) and R fuse blocks - 250V . . . . . . . . . . . . .294-295
Class H(K) and R fuse blocks - 600V . . . . . . . . . . . . .296-297
Class J fuse blocks J600, JP, JA Add-a-Pole  . . . . . . .298-299
Class T fuse blocks - 300V . . . . . . . . . . . . . . . . . . . .300-301
Class T fuse blocks - 600V . . . . . . . . . . . . . . . . . . . .302-303
Add-on fuse blocks BCA, BMA  . . . . . . . . . . . . . . . . . . . . .304
Class CC, Type M and Class G fuse blocks BC, BCCM, 

BG, BM, G  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .305

Modular fuse blocks BH  . . . . . . . . . . . . . . . . . . . . . . . . . .306
Box cover units for plug fuses SCY, SKA, SOU, SOW, 

SOX, SOY, SRU, SRW, SRX, SRY, SSN, SSU, SSW, SSX, 
SSY, STY,   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .307

In-line fuse holders HFA, HFB, HHB, HHT, HM, 

HR, HRK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308-309

Tron

in-line fuse holders

HEB, HEC, HEG, HEH, HEJ, HET, 

HEX, HEY, 

HEZ

 . . . . . . . . . . . . . . . . . . . . . . . . . . .309-311

Panel mounted fuse holders (including indicating) HJL, HK, 

HKP, HLD,HPC, HPD, HPF, HPG, HPM, HPS, HPS, HTB, 
HTC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312-318

Fuse blocks for 

1

4

" x 1 

1

4

" and 

1

4

" x 1" fuses  . . . . . . .319-320

Fuse blocks for 

13

32

" x 1 

1

2

" fuses  . . . . . . . . . . . . . . . . . . .321

Rail mount fuse blocks & holders  . . . . . . . . . . . . . . . . . . .322

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

9

Circuit Protection Products for the Electrical Industry

Table of Contents

RED 

indicates

NEW 

information

Power Distribution Blocks  . . . . . . . . . . . . .323-332

Power Distribution Block Selection Chart . . . . . . . . . . . . . .324
PDBFS  Series finger-safe power distribution blocks  . . . . .325
PDB Series power distribution blocks  . . . . . . . . . . . . . . . .326
163 Series power terminal blocks  . . . . . . . . . . . . . . .327-328
Series 11675 & 11725 power terminal blocks  . . . . . . . . .329
Series 160, 162, 163 & 165 power terminal blocks  . . . . .329
Series 162, 163 & 165 power stud terminal blocks . . . . . .330
Series 160, 162, 163 & 165 power splicer terminal 

blocks  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .330

Series 14002 (barrier) & 14004 (dead front) terminal 

blocks  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331

Connectors  . . . . . . . . . . . . . . . . . . . . . . . .333-378

DIN-Rail

Feed through blocks (DS series)  . . . . . . . . . . . . . . . . . . . .334
Feed through blocks (DP series)  . . . . . . . . . . . . . . . .335-336
Mini feed through blocks (DM series)  . . . . . . . . . . . . . . . .337
Double level blocks (DDP series) . . . . . . . . . . . . . . . . . . . .338
Disconnect blocks (DG series) . . . . . . . . . . . . . . . . . .339-340
Fuse holder blocks (F520 series) . . . . . . . . . . . . . . . .341-342
Internally jumpered blocks (DDNS series)  . . . . . . . . . . . . .343
Test blocks (DTST2 series)  . . . . . . . . . . . . . . . . . . . . . . . .343
Panel mount blocks  . . . . . . . . . . . . . . . . . . . . . . . . .344-345
Short-Circuit Current Ratings (SCCRs)  . . . . . . . . . . . .346-347
Top screw-on bridges  . . . . . . . . . . . . . . . . . . . . . . . . . . .348
End brackets  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349
Partition plates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349
Jumper slides  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .350
Top insertion bridges  . . . . . . . . . . . . . . . . . . . . . . . . . . . .350
Side insertion bridges . . . . . . . . . . . . . . . . . . . . . . . .351-352
Mounting rails and brackets  . . . . . . . . . . . . . . . . . . . . . . .353
Marking system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354
Marking labels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .355-357
Feed through blocks (NDN series)  . . . . . . . . . . . . . . .358-359
Feed through blocks (C-Rail series)  . . . . . . . . . . . . . .360-361
Depluggable blocks  . . . . . . . . . . . . . . . . . . . . . . . . .362-363
Multi-pole panel mount blocks  . . . . . . . . . . . . . . . . . . . . .364
Quick connect blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . .365

Panel Mount

Series TB100 2- to 36-Pole blocks  . . . . . . . . . . . . . .366-367
Series TB200 & TB200HB 2- to 30-Pole blocks . . . . .368-369
Series TB300 & TB345 2- to 24-Pole blocks  . . . . . . .370-371
Marking options and covers for double row series  . . . . . . .372
Top & bottom marking strips for terminal blocks  . . . . . . . .373
Series TB400 2- to 12-Pole blocks . . . . . . . . . . . . . . . . . .374
Series KU 2- to 12-Pole panel mount blocks . . . . . . . . . . .375
Series C7021 1- to 6-Pole block  . . . . . . . . . . . . . . . . . . .376
Series C7024 1- to 12-Pole block  . . . . . . . . . . . . . . . . . .377

Disconnects . . . . . . . . . . . . . . . . . . . . . . . .379-424

Compact Circuit Protector (CCP) disconnect switches

30A Class CC, Midget & 10x38 . . . . . . . . . . . . . . . . . . 380-381

30A 60A and 100A Class CF . . . . . . . . . . . . . . . . . . . . 382-383

CCPB - Compact Circuit Protector Base . . . . . . . . . . . . 384-385

UL 98 fused disconnect switches 30 to 800A

Introduction & Agency Information . . . . . . . . . . . . . . . . . . . . 386
Product Line Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387
30A Compact Class CC & Class J . . . . . . . . . . . . . . . . 388-389
30A Class J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390-391
60A Compact Class J . . . . . . . . . . . . . . . . . . . . . . . . . 392-393
60A Class J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394-395
100A Class J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396-397
200A & 400A Class J . . . . . . . . . . . . . . . . . . . . . . . . . 398-400
600A Class J and 800A Class L. . . . . . . . . . . . . . . . . . 402-403

UL 98 non-fused disconnect switches 30 to 1200A

Introduction & Agency Information . . . . . . . . . . . . . . . . . . . . 404
Product Line Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405
30A, 60A and 100A Compact . . . . . . . . . . . . . . . . . . . 406-407
100A, 200A and 400A Standard . . . . . . . . . . . . . . . . . 408-409
600A, 800A, 1000A and 1200A Standard . . . . . . . . . . 410-411

UL 508 non-fused disconnect switches 16 to 80A

Introduction and Agency Information . . . . . . . . . . . . . . . . . . 412
Product Line Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413
16A, 25A, 40A, 63A and 80A Standard . . . . . . . . . . . . 414-416

Enclosed UL 98 & UL 508 disconnect switches

Introduction & Agency Information . . . . . . . . . . . . . . . . . . . . 417

Fused UL 98 

30A to 800A Enclosed Disconnects . . . . . . . . . . . . . . . 418-419

Non-Fused UL 98 

30 to 1200A Enclosed Disconnects . . . . . . . . . . . . . . . 420-421

Non-Fused UL 508 

16 to 80A Enclosed Disconnects . . . . . . . . . . . . . . . . . 422-423

Fused, dead front disconnect switches . . . . . . . . . . . . . . . . 424

Telecom Protection Devices  . . . . . . . . . . .425-439

Telpower compact fused disconnect switch . . . . . . . . . . . .426
Telpower miniature fused disconnect switch  . . . . . . . . . . .427
Fused disconnect switches for TPA fuses  . . . . . . . . .428-429
Fused disconnect switches for TPS fuses  . . . . . . . . . . . . .430
Fused disconnect switches  . . . . . . . . . . . . . . . . . . . .431-437
Telpower specialty fuses  . . . . . . . . . . . . . . . . . . . . . .438-439

Surge Protective Devices (SPD)  . . . . . . . .441-460

SurgePOD HEAVY DUTY SPD  . . . . . . . . . . . . . . . . . .442-445
SurgePOD PRO SPD  . . . . . . . . . . . . . . . . . . . . . . . . .446-448
UL DIN-Rail - High SCCR SPDs

1-Pole, Type 2, BSPM_S2G  . . . . . . . . . . . . . . . . . . .449-450
2-Pole, Type 2, BSPM_S3G  . . . . . . . . . . . . . . . . . . .451-452

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

10

Circuit Protection Products for the Electrical Industry

Table of Contents

Catalog Sections

Page

Low Voltage, Branch Circuit Rated Fuses...17

Solar Fuse Products.....................................53

Low Voltage Supplementary Fuses .............71

Electronic - PC Board and Small

Dimension Fuses ..........................................85

Medium Voltage Fuse and Fuse Links ........99

High Speed Fuses.......................................121

IEC & British Standard Fuses ....................245

Quik-Spec

Electrical Gear .......................265

Fuse Holders and Blocks ...........................273

Power Distribution & Terminal Blocks ......323

Connectors .................................................333

Disconnects................................................379

Telecom Protection Devices (SPD) ............425

Surge Protective Devices...........................441

Accessories ................................................503

Services & Application Guide ....................511

Index by Part Number ................................532

RED 

indicates

NEW 

information

Surge Protective Devices (SPD) - (Continued)

3-Pole, Type 2, BSPM_WYG/DLG  . . . . . . . . . . . . . . .453-454
4-Pole, Type 2, BSPM_WYNG/HLG  . . . . . . . . . . . . . .455-456

UL DIN-Rail - Low Voltage AC/DC Power

1-Pole, Type 2, BSPM_LV  . . . . . . . . . . . . . . . . . . . . .457-458

UL DIN-Rail - Low Voltage AC/DC Control

2-Pole, Type 3, BSPH2A_LV  . . . . . . . . . . . . . . . . . . .459-460

IEC DIN-Rail - Class I

2-Pole, Class I, BSPS_TN/TT  . . . . . . . . . . . . . . . . . .461-462
3-Pole, Class I, BSPS_TNC  . . . . . . . . . . . . . . . . . . . .463-464
4-Pole, Class I, BSPS_TNS/TT  . . . . . . . . . . . . . . . . .465-466

IEC DIN-Rail - Class II

1-Pole, Class II, BSPM_TN / BSPG_NPE  . . . . . . . . . .467-468
2-Pole, Class II, BSPM_TN / BSPH_TT  . . . . . . . . . . .469-470
3-Pole, Class II, BSPM_TNC  . . . . . . . . . . . . . . . . . . .471-472
4-Pole, Class II, BSPM_TNS / BSPH_TT  . . . . . . . . . .473-474

PV DIN-Rail - Lightning Arrester

1-Pole, PV Advance Lightning Arrester / BSPS_PV  . . .475-476

PV DIN-Rail - SPDs

2-Module, PV HEAVY DUTY SPD / BSPH2_PV  . . . . . .477-478
3-Module, PV HEAVY DUTY SPD / BSPH_YPV  . . . . . .479-480
3-Module, PV PRO SPD / BSPP_YPV . . . . . . . . . . . . .481-482

Wind Power DIN-Rail - Class I

1-Pole, Class I, BSPS_WE  . . . . . . . . . . . . . . . . . . . .483-484

Wind Power DIN-Rail - Class II

1-Pole, Class II, BSPM_WE / BSPS_WE  . . . . . . . . . .485-486
2-Pole, Class II, BSPM_WE / BSPH_WE  . . . . . . . . . .487-488
3-Pole, Class II, BSPM_WE . . . . . . . . . . . . . . . . . . . .489-490
4-Pole, Class II, BSPM_WE / BSPH_WE  . . . . . . . . . .491-492

UL 4978 Data Signals SPDs  . . . . . . . . . . . . . . . . . . . .493-501
SurgePOD™ Series, 150 to 550Vac MCOV . . . . . . . . .502-503

DIN-Rail TVS Series with holder  . . . . . . . . . . . . . . . . . . . . .504

Accessories  . . . . . . . . . . . . . . . . . . . . . . . .505-512

Bussmann service kits and assortments  . . . . . . . . . .506-508
Clip clamps and rail adapters (DIN & American) . . . . . . . . .509
Spare fuse holders, 

pullers,

testers and cabinets . . . . . . . .510

Fuse reducers and dummy "neutrals" . . . . . . . . . . . . . . . .511

Services & Application Guide  . . . . . . . . . . . . . .513

Testing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .514
Custom Products  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .515

Application Guide . . . . . . . . . . . . . . . . . . . . . . . . . .516-525

Bussmann fuse technology  . . . . . . . . . . . . . . . . . . . .516-522
Motor Circuit Branch Circuit Protection  . . . . . . . . . . . . . . .523
Glossary  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .524-526

Out-of-Stock Substitutions/Upgrades  . . . . . . . . . . . . . . . .526

Commercial & industrial fuse applications . . . . . . . . . . . . .527

FUSEFinder cross reference  . . . . . . . . . . . . . . . . . . . . . . .528
FC

2

Mobile App  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .530

Index by Part Number  . . . . . . . . . . . . . . . .532-537
Low-Peak Upgrade  . . . . . . . . . . . . . .

Inside back cover

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Circuit Protection Products for the Electrical Industry

Services &

Application Guide

Services &

Application Guide

Low Voltage

Branch Circuit

Low Voltage

Branch Circuit

Low Voltage

Supplementary

Low Voltage

Supplementary

Electronic

Fuses

Electronic

Fuses

Medium Voltage

Fuses

Medium Voltage

Fuses

High Speed

Fuses

High Speed

Fuses

IEC & British

Standard Fuses

IEC & British

Standard Fuses

Quik-Spec™

Electrical Gear

Quik-Spec™

Electrical Gear

Fuse Holders

& Blocks

Fuse Holders

& Blocks

Power Distribution

& Terminal Blocks

Power Distribution

& Terminal Blocks

Connectors

Connectors

Disconnects

Disconnects

Index by

Part Number

Index by

Part Number

Telecom Protection

Devices

Telecom Protection

Devices

Surge Protection

Devices

Surge Protection

Devices

Accessories

Accessories

Solar

Products

Solar

Products

New

Product

New

Product

New

Product

New

Product

New

Product

New

Product

PEEL & STICK TABS

Mark the products that are important to you. 

Write Your Own 
Descriptions Here

11

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

12

Circuit Protection Products for the Electrical Industry

Selecting Circuit Protection

The following fuse selection guides are based on the 2011
NEC

®

and provided fuse recommendations for the various

applications listed.

These are only suggestions. Final fuse selection should be
performed only by qualified personnel able to fully assess an
application’s circuit protection requirements. If you need
assistance in selecting a fuse for a particular application, call

the Cooper Bussmann Application Engineering team for
technical and application support Monday – Friday, 8:00 a.m.
– 5:00 p.m. Central Time.

Application Engineering can be reached via phone and 
e-mail:

• Toll-free phone: 855-287-7626 (855-BUSSMANN)
• E-mail: fusetech@cooperindustries.com

Fuse & Holder Recommendations

Fuse

Holder(s)

Fuse

Holder(s)

BAF

HEB

KTK-R

HEY

KTK

HEX

FNQ-R

FNM

HPC-D

LP-CC

FNQ

Mercury, Sodium, etc.

Fluorescent

All Other (Mercury,
Sodium, etc.)

Indoor

Outdoor

Consult fixture manufacturer for size and type.

Consult fixture manufacturer for size and type.

Consult fixture manufacturer for size and type.

Fuse & Holder Recommendations

Fuse

Holder(s)

Fuse

Holder(s)

GLR

HLR

GLQ

HLQ

GMF

GMQ

GRF

Ballasts

Fuse & Holder Recommendations

Fuse

Holder(s)

Fuse

Holder(s)

Fuse

Holder(s)

BAF

HPF

KTK-R

HPS-RR

SC 0-15

HPF-EE

KTK

HPS

FNQ-R

HPF-RR

HPS-EE

FNM

LP-CC

SC 20

HPF-JJ

FNQ

HPS-JJ

KTQ

HPS-L

SC 25-30 HPF-FF

BBS

HPF-L

HPS-FF

Capacitors (NEC

®

460)

Protected by

Time-Delay Fuses.

150% to 175% of Full Load Current

On Load Side of Motor Running

Overcurrent Device.

Protection recommended as shown, but not required.

Protected by

Non-Time-Delay Fuses.

250% to 300% of Full Load Current.

Fuse Recommendations

Volts

Fuse(s)

0-250

LPN-RK_SP, FRN-R

0-600

LPS-RK_SP, FRS-R
LPJ_SP, LP-CC, 
FNQ-R, TCF

Fuse Recommendations

Volts

Fuse(s)

0-250

KTN-R, NON

0-300

JJN

0-600

KTS-R, NOS
JKS, KTK-R
JJS, FCF_RN

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

13

Selecting Circuit Protection

Circuit Protection Products for the Electrical Industry

Mains, Feeders, Branches (NEC

®

430)

Feeder Circuits

(600A & Less)

Fuse Recommendations

Volts

Fuse(s)

0-25O

LPN-RK_SP, FRN-R

0-600

LPS-RK_SP, FRS-R

0-600

LPJ- SP, LP-CC

Motor Loads

No Motor Load

Combination Motor
Loads and Other Loads

100% of non-continuous load plus 125% of continuous load.

150%* of the FLA of largest motor (if there are two or more
motors of same size, one is considered to be the largest) plus
the sum of all the FLA for all other motors plus 100% of non-
continuous, non-motor load plus 125% of continuous, non-
motor load.

150%* of the FLA of largest motor (if there are two or more
motors of same size, one is considered to be the largest) plus
the sum of all the FLA for all other motors.

*A max. of 175% (or the next standard size if 175% does not
correspond to a standard size) is allowed for all but wound
rotor and all dc motors.

Fuse Recommendations

Volts

Fuse(s)

0-250

LPN-RK_SP, FRN-R

0-300

JJN

0-600

LPS-RK_SP, FRS-R

0-600

JJS

0-600

LPJ_SP, LP-CC
JKS, KTK-R, LPT

Main, Branch &

Feeder Circuits

(601-6000A)

150% to 225% of full load current of largest motor plus 100%
of full load current of all other motors plus 125% of continuous
non-motor load plus 100% of non-continuous non-motor load.

Fuse Recommendation

Volts

Fuse(s)

0-600

KRP-C_SP

Electric Heat (NEC

®

424)

Electric Space Heating

Size at 125% or next size larger but in no case larger than
60 amps for each subdivided load.

Electric Boilers with

Resistance Type Immersion

Heating Elements in an ASME

Rated and Stamped Vessel

Size at 125% or next size larger but in no case larger than
150 amps for each subdivided load.

Fuse Recommendation

Volts

Fuse(s)

0-250

LPN-RK_SP
FRN-R, NON

0-300

JJN

0-480

SC 25 to SC 60

0-600

LPS-RK_SP
FRS-R, NOS

0-600

JJS

0-600

LPJ_SP, LP-CC
FNQ-R, JKS, KTK-R,
TCF, SC 

1

2

to SC 20,

FCF_RN

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

14

Circuit Protection Products for the Electrical Industry

Selecting Circuit Protection

Above 600V

600V & Less

Fuse Recommendations

Volts

Fuse(s)

0-250

LPN-RK_SP, FRN-R

0-600

LPS-RK_SP, FRS-R
LPJ_SP, TCF

Fuse Recommendations

Volts

Fuse(s)

0-250

KTN-R, NON

0-300

JJN

0-600

KTS-R, NOS
JJS
LP-CC, JKS, KTK-R,
LPT, FCF_RN

Short-Circuit Only

Backup Overload w/
Motor Starter & Short-
Circuit Protection

Short-Circuit Only

Protected by Time-
Delay Fuses

Protected by Non-
Time Delay Fuses &
all Class CC Fuses

Compare the min. melting time-current characteristics of the fuses with the time-current characteristics of the overload relay
curve. The size fuse which is selected should be such that short.circuit protection is provided by the fuse and overload 
protection is provided by the controller overload relays.

Fuse Recommendations

Volts

Fuse(s)

2400

JCK, JCK-A, JCH

4800

JCL, JCL-A, JCG

7200

JCR, 7.2 WKMSJ

Motor Loads (NEC

®

430)

125% of motor FLA or next size larger.

130% of motor FLA or next size larger.

175%* of motor FLA or next size larger. (If 175% does not 
correspond to a standard size). If this will not allow motor to
start, due to higher than normal inrush currents or longer than
normal acceleration times (5 sec. or greater), fuse may be
sized up to 225% or next size smaller.

Max. of 300%* of motor FLA or next size larger (if 300% does
not correspond to a standard size). If this will not allow motor
to start due to higher than normal inrush currents or longer
than normal acceleration times (5 sec. or greater), fuses
through 600 amps may be sized up to 400% or next size
smaller.

Fuse Sized For:

*150% for wound rotor and all DC motors.

Fuse Recommendations

Volts

Fuse(s)

0-250

FRN-R

0-600

FRS-R

Fuse Recommendations

Volts

Fuse(s)

0-250

LPN-RK_SP

0-600

LPS-RK_SP

Solenoids (Coils)

Branch Circuit

Fuses

Size at 125% or next size smaller.

Fuse Recommendation

Volts

Fuse(s)

0-250

Best: LPN-RK_SP
FRN-R

0-600

LPS-RK_SP
FRS-R

0-600

LPJ_SP, LP-CC
FNQ-R, TCF

Supplementary

Fuses

Size at 125% or next size larger.

Fuse Recommendation

Volts

Fuse(s)

0-32

MDL 9-30A,
FNM 20-30A

0-125

MDA 25-30A,
FNM 12-15A

0-250

MDL 

1

16

-8A,

MDA 

2

10

-20A,

FNM 

1

10

-10A,

MDQ 

1

100

-7A

0-500

FNQ 

1

10

-30A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

15

Selecting Circuit Protection

Circuit Protection Products for the Electrical Industry

Primary

Protection

Only

*When 125% of FLA corresponds to
a standard rating, the next larger size
is not permitted.

Primary and

Secondary
Protection

Optimum Protection

125% or next size larger

125% or next size larger

125% or next size larger

Max. of 125% or next larger*

NEC

®

Maximums

Max. 300% or next size smaller (See
NEC

®

430.72(C) for control circuit

transformer maximum of 500%

Max. 167% or next size smaller

Maximum Fuse Size

% of Primary FLA

(or next FLA size smaller)

A = 250%
B = 250%
C = 600%
D = 600%
E = 400%
F = 400%

% of Secondary FLA

A = 167% or next size smaller
B = 125% or next size larger*
C = 167% or next size smaller
D = 125% or next size larger*
E = 167% or next size smaller
F = 125% or next size larger*

Rated secondary current 9
amps or greater

Rated secondary current
less than 9 amps

Transformer
Impedance of 6%
or Less

Rated secondary current 9
amps or greater

Rated secondary current
less than 9 amps

Transformer
Impedance of
More Than 6%
But Less Than
10%

Rated secondary current
less than 9 amps

Rated secondary current 9
amps or greater

Without Thermal
Overload
Protection

With Thermal
Overload
Protection

Note: Components on the secondary still
need overcurrent protection

Rated primary current less
than 2 amps

Rated primary current
greater than or equal to 9
amps

Rated primary current
greater than or equal to 2
amps but less than 9 amps

Transformers 600V Nominal or Less (NEC

®

450.3)

Fuse Recommendations

Volts

Fuse(s)

250V

LPN-RK_SP, FRN-R

600V

KRP-C_SP, LPJ_SP, LPS-RK_SP, FNQ-R, FRS-R, TCF

A

A

B

C

D

E

F

B

C

D

E

F

Primary and secondary
fuses at 125% of prima-
ry and secondary FLA or
next size larger

Maximum Fuse Size

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

16

Circuit Protection Products for the Electrical Industry

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

Selecting Circuit Protection

Solid State Devices (Diodes, SCRs, Triacs, Transistors)

Short-Circuit

Protection

Only

“F,” “S,” “K,” & 170M Series fuses sized up to several sizes
larger than full load RMS or DC rating of device.

Fuse Recommendations

Volts

Fuse(s)

0-130

FWA

0-250

FWX

0-500

FWH

0-600

FWC, KAC, KBC

0-700

FWP, 170M Series, 
SPP

0-1000

FWJ, 170M Series, 
SPJ

Supervised

Installations

Unsupervised
Installations

Transformers Over 600V Nominal (NEC

®

450.3)

Fuse Recommendations

Volts

Fuse(s)

250V

LPN-RK_SP, FRN-R

600V

LPS-RK_SP, LPJ-_SP,
KRP-C_SP, FRS-R, FNQ-R,
TCF

2475V

JCD

2750V

JCX

2750/5500V

JCW

5500V

MV05, 5.5 ABWNA, 
5.5 AMWNA, 5.5 FFN

7200V

7.2 AMWNA, 7.2 TDLSJ, 
7.2 TFLSJ

8300V

JCZ, JDZ, 8.25 FFN

15500V

MV155, 15.5 CAVH

17500V

17.5 CAV, 17.5 TDM

24000V

24 TDM, 24 TFM, 24 FFM

36000V

36 CAV, 36 TDQ, 36 TFQ

38000V

38 CAV

Note: Components on the secondary still need
overcurrent protection

Primary at code max. of 250% or
next standard size if 250% does not 
correspond to a standard rating

Primary
Protection
Only

Transformer
Impedance Less
Than or Equal to 6%

Primary
at code
max. of
300%

Secondary
Over 600V

Secondary at
code max. of
250%

Secondary at
code max. of
250%

Secondary at
code max. of
225%

Secondary
Over 600V

Primary
at code
max

.

of

300%

Secondary at
code max. of
250%

Secondary
Over 600V

Primary at code max. of
300% or next standard size
if 300% does not corre-
spond to a standard rating

Transformer
Impedance Less
Than or Equal to 6%

Primary at code max. of
300% or next standard size
if 300% does not corre-
spond to a standard rating

Secondary
Over 600V

Secondary at code max. of
125% or next standard size
if 125% does not corre-
spond to a standard rating

Secondary at code max. of
225% or next standard size
if 225% does not corre-
spond to a standard rating

Secondary at code max. of
125% or next standard size
if 125% does not corre-
spond to a standard rating

Secondary at code max. of
250% or next standard size
if 250% does not corre-
spond to a standard rating

Transformer
Impedance Greater
Than 6% But Less
Than 10%

Secondary
600V or
Below

Secondary
600V or
Below

Primary
and
Secondary
Protection

Transformer
Impedance Greater
Than 6% But Less
Than 10%

Secondary
600V or
Below

Secondary
600V or
Below

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

17

Lo
w V

oltage

Branch Circuit

Fuses

Page

Fuse Holder & Block Selection Guide       18-20
Class Fuse Dimensions

21-22

Fuses By Fuse Class

Class

Fuses

Volts

CC . . . . . .

LP-CC  . . . . . . . . . . . . . . . 600V . . . . .

23

FNQ-R . . . . . . . . . . . . . . . 600V . . . . .

24

KTK-R . . . . . . . . . . . . . . .  600V . . . . .

25

CF . . . . . . .

TCF* . . . . . . . .  . . . . . . . . 600V . . . . . 26-27

FCF. . . . . . . . . . . . . . . . . .  600V . . . . . 28-29
WCF. . . . . . . . . . . . . . . . .  600V . . . . . 30-31

*Class J performance

CF . . . . . . .

Holder System . . . . . . . . . 600V . . . . . 32-33

G . . . . . . .

SC . . . . . . . . . . . . . . . . . . 600/480V . .

34

J . . . . . . .

LPJ-_SP . . . . . . . . . . . .    600V . . . . .

35

LPJ-_SPI Indicator . . . . .   600V . . . . .

35

JKS . . . . . . . . . . . . . . . . . 600V . . . . .

36

K5 & H . . .

NON . . . . . . . . . . . . . . . . 250V . . . . .

37

NOS  . . . . . . . . . . . . . . . .  600V . . . . .

37

L . . . . . . .

KRP-C_SP . . . . . . . . . . . . 600V . . . . . 38-39
KRP-CL . . . . . . . . . . . . . . 600V . . . . .

39

KLU . . . . . . . . . . . . . . . . . 600V . . . . .

40

KTU . . . . . . . . . . . . . . . . . 600V . . . . .

40

RK1 . . . . .

LPN-RK_SP . . . . . . . . . . . 250V . . . . . 41-43
LPN-RK_SPI Indicator . . . 250V . . . . . 41-43
LPS-RK_SP . . . . . . . . . . . 600V . . . . . 41-43
LPS-RK_SPI Indicator . . .  600V . . . . . 41-43
KTN-R . . . . . . . . . . . . . . . 250V . . . . .

44

KTS-R . . . . . . . . . . . . . . . 600V . . . . .

45

RK5 . . . . .

FRN-R (Energy Efficient). . . 250V . . . . .

46

FRN-R_ID (Energy Efficient).600V . . . . .

46

FRS-R (Energy Efficient). . . 600V . . . . .

47

FRS-R_ID (Energy Efficient).600V . . . . .

47

T . . . . . . .

JJN . . . . . . . . . . . . . . . . . 300V . . . . .

48

JJS . . . . . . . . . . . . . . . . . 600V . . . . .

49

Plug Fuses

W, SL, TL, S, 

T, P, TC Series & MB
Edison Base Circuit
Breakers, SA . . . . . . . . . 125V . . . . . 50-52

Low Voltage, Branch
Circuit Rated Fuses

RED 

indicates

NEW 

information

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

18

Low Voltage, Branch Circuit Rated Fuses

Holders & Blocks For Branch Circuit Rated Fuses

Class

Fuses

Volts

Page

CC

LP-CC

600V . . . . . . . . . . . . . . . . . . . . 23

FNQ-R

600V . . . . . . . . . . . . . . . . . . . . 24

KTK-R

600V . . . . . . . . . . . . . . . . . . . . 25

Holders

• OPM-NG-SC3 3-pole, panel/DIN rail mount . . . . . . . . . . . . 284
• OPM-1038R 3-pole, panel/DIN rail mount . . . . . . . . . . . . . 283
• OPM-1038RSW 3-pole w/ switch, panel/DIN rail mount  . . 282

• CHCC_D 1 to 3-pole, DIN rail mount . . . . . . . . . . . . . . . . . 274

• HPF-RR, front panel mount . . . . . . . . . . . . . . . . . . . . . . .  317
• HPS-RR, front panel mount . . . . . . . . . . . . . . . . . . . . . . . 317

Blocks

• BC Series, panel mount . . . . . . . . . . . . . . . . . . . . . . . . . .  305

Class

Fuses

Volts

Page

G

SC

600/480V . . . . . . . . . . . . . . . . . 34

Holders

• HP Series front panel accessible, front panel mount . . . . . 317

Blocks

• BG Series, panel/DIN rail with adapters . . . . . . . . . . . . . . 305
• G Series, panel/DIN rail with adapters . . . . . . . . . . . . . . .  305

Class

Fuses

Volts

Page

K5 & H

NON

250V . . . . . . . . . . . . . . . . . . . . 37

NOS

600V . . . . . . . . . . . . . . . . . . . . 37

Blocks

• Modular Knifeblade Fuse Blocks 250/600V, panel mount . . 289

• Modular Type Fuse Blocks 250/600V, panel mount . . . . . . 306
• H250 Series 1 to 3-pole 250V, panel mount . . . . . . . . . . . .294
• H600 Series 1 to 3-pole 600V, panel mount  . . . . . . . . . . . 296

OPM-NG-SC3

CHCC_D

HPF-RR

HPS-RR

BC Series

HP Series

BG & G Series

Modular Knifeblade

Modular Type

H250 Series

H600 Series

OPM-1038R & 

OPM-1038RSW

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

19

Lo
w V

oltage

Branch Circuit

Fuses

Holders & Blocks For Branch Circuit Rated Fuses

Class

Fuses

Volts

Page

RK1

LPN-RK_SP

250V . . . . . . . . . . . . . . . . . . . . .41

LPS-RK_SP

600V . . . . . . . . . . . . . . . . . . . . .41

KTN-R

250V . . . . . . . . . . . . . . . . . . . . 44

Blocks

• Modular Knifeblade Fuse Blocks 250/600V, panel mount . . .289

• R250 Series 1- to 3-pole 250V, panel mount . . . . . . . . . . . .294
• R600 Series 1- to 3-pole 600V, panel mount . . . . . . . . . . . .296

Class

Fuses

Volts

Page

RK5

FRN-R

250V . . . . . . . . . . . . . . . . . . . . 46

Blocks

• Modular Knifeblade Fuse Blocks 250/600V, panel mount . . . 289

• R250 Series 1-  to 3-pole 250V, panel mount . . . . . . . . . . . .294
• R600 Series 1-  to 3-pole 600V, panel mount . . . . . . . . . . . .296

51215

51235

R250 Series

R250 Series

R600 Series

R600 Series

BH Series

T600 Series

T300 Series

Class

Fuses

Volts

Page

L

KRP-C_SP

600V . . . . . . . . . . . . . . . . . . . . 38

KRP-CL

600V . . . . . . . . . . . . . . . . . . . . 39

KLU

600V . . . . . . . . . . . . . . . . . . . . 40

KTU

600V . . . . . . . . . . . . . . . . . . . . 40

Blocks

• 51215 1-pole, panel mount*
• 51235 3-pole, panel mount*

*Call our customer satisfaction team at 636-527-3877 for more information.

Class

Fuses

Volts

Page

T

JJN

300V . . . . . . . . . . . . . . . . . . . .  48

JJS

600V . . . . . . . . . . . . . . . . . . . . 49

Blocks

• BH Series modular-style, panel mount (<60A) . . . . . . . . . . 306
• T300 Series 1 to 4-pole 300V, panel mount . . . . . . . . . . . .300
• T600 Series 1 to 3-pole 600V, panel mount . . . . . . . . . . . .302

Modular Knifeblade

Modular Knifeblade

Low Voltage, Branch Circuit Rated Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

20

Low Voltage, Branch Circuit Rated Fuses

Class

Fuses

Volts

Page

Plug Fuses

W, SL*, TL, S*,
T, P and TC
Series

125V . . . . . . . . . . . . . . . . . . 50-52

Box Cover Units

• Standard electrical box mounting . . . . . . . . . . . . . . . . . . .  307

*Use of SL & S rejection fuses requires SA adapters, see page 52

Fuse Only

With Grounded

Outlet

With Switch

Class

Fuses

Volts

Page

J, CF

TCF*, 

FCF, WCF

600V  . . . . . . . . . . . . . . . . 31

LPJ-SP

600V  . . . . . . . . . . . . . . . . 35

JKS

600V  . . . . . . . . . . . . . . . . 36

*Class J performance

Holders

• TCFH CUBEFuse holder, panel/DIN-Rail mount . . . . . . .  32-33
• CH Series Class J modular 1- to 3-pole, panel/

DIN rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281

• Safety J™ Series modular holders,   

panel/DIN rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286

Blocks

• Modular Knifeblade Fuse Blocks 250/600V, panel mount . . 289

• Modular Type Fuse Blocks 600V, panel mount . . . . . . . . . .306
• J600 Series, panel mount . . . . . . . . . . . . . . . . . . . . . . . . . 298
• JP Series pyramid blocks, panel mount . . . . . . . . . . . . . . . 299
• BH Series modular-style open blocks, panel mount . . . . .  306

TCFH

CH Series

J600 Series

JP Series

BH Series

Safety J™ Series

Modular Type

Holders & Blocks For Branch Circuit Rated Fuses

Equipment

Desired Fuse

Catalog No.

Fuse Clip Amps

(Case) Amp Size

(Pairs) 250V

60

30

NO.263-R

100

30

NO.213-R

60

NO.216-R

200

60

NO.226-R

100

NO.2621-R

400

100

NO.2641-R

200

NO.242-R

600

100

NO.2661-R

200

NO.2662-R

400

NO.2664-R*

*Single reducer only (pair not required).

Equipment

Desired Fuse

Catalog No.

Fuse Clip Amps

(Case) Amp Size

(Pairs) 600V

60

30

NO.663-R

100

30

NO.216-R

60

NO.616-R

200

60

NO.626-R

100

NO.2621-R

400

100

NO.2641-R

200

NO.642-R

600

100

NO.2661-R

200

NO.2662-R

400

NO.2664-R*

*Single reducer only (pair not required).

Fuse Reducers For Class R Fuses 250V

Fuse Reducers For Class R Fuses 600V

Modular

Knifeblade

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

21

Lo
w V

oltage

Branch Circuit

Fuses

Class J Dimensions - in (mm)

Low-Peak and Limitron Fuses
LPJ & JKS — 600V

Amp Range

A

B

C

D

E

F

G

H

I

1-30

2.25 (57.2)

0.81 (20.6)

0.50 (12.7)

35-60

2.38 (60.3)

1.06 (27.0)

0.63 (15.9)

65-100

4.63 (117.5)

1.13 (28.6)

3.63 (92.1)

2.63 (66.7)

1.00 (25.4)

0.75 (28.6)

0.13 (3.2)

0.41 (10.4)

0.28 (7.1)

110-200

5.75 (146.1)

1.63 (41.4)

4.38 (111.1)

3.00 (76.2)

1.38 (34.9)

1.13 (28.6)

0.19 (4.8)

0.38 (9.5)

0.28 (7.1)

225-400

7.12 (181.0)

2.11 (53.6)

5.25 (133.3)

3.26 (82.8)

1.87 (47.6)

1.62 (41.2)

0.25 (6.4)

0.56 (14.2)

0.40 (10.3)

450-600

8.00 (203.2)

2.60 (66.0)

6.00 (152.4)

3.31 (84.0)

2.12 (54.0)

2.00 (50.8)

0.53 (13.5)

0.72 (18.3)

0.53 (13.5)

21

Branch Circuit Rated Fuse Dimensions

Class RK1 & RK5 Dimensions - in (mm)

Basic dimensions are same as Class H (formerly NEC) One-Time (NON & NOS) and Superlag Renewable RES & REN fuses.
NOTE: These fuses can be used to replace existing Class H, RK1 and RK5 fuses relating to dimensional compatibility.

Ferrule Styles

Amp

250V

600V

Range

A

B

A

B

1

10

-30

2 (50.8)

0.56 (14.3)

5.0 (127.0)

0.81 (20.6)

35-60

3 (76.2)

0.81 (20.6)

5.5 (139.7)

1.06 (27.0)

Fusetron — (FRN-R & FRS-R)& Limitron — (KTN-R & KTS-R)

Amp

250V

600V

Range

A

B

A

B

70-100

5.88 (149.2)

1.06 (26.9)

7.88 (200.0)

1.34 (34.0)

110-200

7.13 (181.0)

1.56 (39.6)

9.63 (244.5)

1.84 (46.7)

225-400

8.63 (219.1)

2.38 (60.5)

11.63 (295.3)

2.59 (65.8)

450-600

10.38 (263.5)

2.88 (73.2)

13.38 (339.7)

3.13 (79.5)

Low-Peak — (LPN-RK & LPS-RK)

Amp

250V

600V

Range

A

B

A

B

70-100

5.88 (149.2)

1.16 (29.5)

7.88 (200.0)

1.16 (29.5)

110-200

7.13 (181.0)

1.66 (42.2)

9.63 (244.5)

1.66 (42.2)

225-400

8.63 (219.1)

2.38 (60.5)

11.63 (295.3)

2.38 (60.5)

450-600

10.38 (263.5)

2.88 (73.2)

13.38 (339.7)

2.88 (73.2)

A

B

A

B

A

B

A

B

B

A

C
D

E

F

G

E

H

I

1A to 60A

65A to 600A

1.5" (

±

0.031)

(38.1mm)

0.41" (

±

0.005)

(10.3mm)

Class CC Dimensions - in (mm)

Low Voltage, Branch Circuit Rated Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

22

Low Voltage, Branch Circuit Rated Fuses

22

Branch Circuit Rated Fuse Dimensions

Class T Dimensions - in (mm)

T-Tron Fuses

JJN — 300V

Amp Range

A

B

C

D

1-30

0.88 (22.2)

0.41 (10.3)

35-60

0.88 (22.2)

0.56 (14.3)

70-100

2.16 (54.8)

0.75 (19.1)

1.56 (39.7)

0.84 (21.4)

110-200

2.44 (61.9)

0.88 (22.2)

1.69 (42.9)

0.84( 21.4)

225-400

2.75 (69.9)

1.00 (25.4)

1.84 (46.8)

0.86 (21.8)

450-600

3.06 (77.8)

1.25 (31.8)

2.03 (51.6)

0.88 (22.2)

601-800

3.38 (85.7)

1.75 (44.5)

2.22 (56.4)

0.89 (22.6)

801-1200

4.00 (101.6)

2.00 (50.8)

2.53 (64.3)

1.08 (27.4)

JJS — 600V

Amp Range

A

B

C

D

1-30

1.50 (14.3)

0.56 (38.1)

35-60

1.56 (20.6)

0.81 (39.7)

70-100

2.95 (19.1)

0.75 (75.0)

2..36 (59.9)

1.64 (41.7)

110-200

3.25 (22.2)

0.88 (82.6)

2.50 (63.5)

1.66 (42.1)

225-400

3.63 (25.4)

1.00 (92.1)

2.72 (69.1)

1.73 (44.1)

450-600

3.98 (31.8)

1.25 (101.2)

2.96 (75.0)

1.78 (45.2) 

601-800

4.33 (44.5)

1.75 (109.9)

3.17 (80.6)

1.88 (47.6)

A

A

B

F

G

D

C1

C2

J1

J1

J2

J2

J3

J3

J4

J4

All Slots and Holes

I

801A

to

2000A

601A

to

800A

2001A

to

3000A

3500A

to

4000A

4500A

to

6000A

Class L Dimensions - in (mm)

Low-Peak and Limitron Fuses

Amp
Range

A

B

C1

C2

D

F

G

I

J1

J2

J3

J4

601-800

8.63 (219.1)

2.40 (61.0)

6.75 (171.5)

5.75 (146.1)

3.75 (95.3)

2.00 (50.8)

0.38 (9.5)

0.63 (15.9)

801-1200

10.75 (273.1)

2.40 (61.0)

6.75 (171.5)

5.75 (146.1)

3.75 (95.3)

2.00 (50.8)

0.38 (9.5)

0.63 (15.9)

1350-1600

10.75 (273.1)

3.00 (76.2)

6.75 (171.5)

5.75 (146.1)

3.75 (95.3)

2.38 (60.3)

0.44 (11.1)

0.63 (15.9)

1800-2000

10.75 (273.1)

3.50 (88.9)

6.75 (171.5)

5.75 (146.1)

3.75 (95.3)

2.75 (69.9)

0.50 (12.7)

0.63 (15.9)

2001-2500

10.75 (273.1)

4.80 (122.0)

6.75 (171.5)

5.75 (146.1)

3.75 (95.3)

3.50 (88.9)

0.75 (19.1)

0.63 (15.9)

1.75 (44.5)

1.38 (34.9)

0.88 (22.2)

0.81 (20.6)

3000

10.75 (273.1)

5.00 (127.0)

6.75 (171.5)

5.75 (146.1)

3.75 (95.3)

4.00 (101.6)

0.75 (19.1)

0.63 (15.9)

1.75 (44.5)

1.38 (34.9)

0.88 (22.2)

0.81 (20.6)

3500-4000

10.75 (273.1)

5.75 (146.1)

6.75 (171.5)

5.75 (146.1)

3.75 (95.3)

4.75 (120.7)

0.75 (19.1)

0.63 (15.9)

1.75 (44.5)

1.38 (34.9)

1.63 (41.3)

0.88 (22.2)

4500-5000

10.75 (273.1)

6.25 (158.8)

6.75 (171.5)

5.75 (146.1)

3.75 (95.3)

5.25 (133.4)

1.00 (25.4)

0.63 (15.9)

1.75 (44.5)

1.38 (34.9)

1.63 (41.3)

0.88 (22.2)

6000

10.75 (273.1)

7.13 (181.0)

6.75 (171.5)

5.75 (146.1)

3.75 (95.3)

5.75 (146.1)

1.00 (25.4)

0.63 (15.9)

1.75 (44.5)

1.38 (34.9)

1.63 (41.3)

0.88 (22.2)

NOTE: KRP-CL (150A to 600A) fuses have same
dimensions as 601-800A case size. KTU (200-600A)
have same dimensions, except tube 3” length x 2”
diameter (76.2 x 50.8mm); terminal 1

5

8

” width x 1

1

4

thick (41.3 x 31.8mm).

JJN 70A to 1200A

JJS 70A to 800A

JJS 35A to 60A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

23

Lo
w V

oltage

Branch Circuit

Fuses

23

LP-CC Class CC

Specifications
Description:

Time-delay, current-limiting,

rejection-type fuse – 12 seconds (minimum)
at 200% rated amps.

Dimensions:

13

32

˝ x 1 

1

2

˝ (10.3 x 38.1mm).

Ratings:

Volts — 600Vac (or less)

— 300Vdc (

1

2

-2

1

2

A & 20-30A)

— 150Vdc (2

8

10

-15A)

Amps — 

1

2

-30A

IR — 200kA RMS Sym.

— 20kA DC

Agency Information:

CE,

Std. 248-4, Class CC, UL Listed,

Guide JDDZ, File E4273, CSA Certified; Class 1422-02, 

File 53787.

Features and Benefits

• Time-delay coupled with Class CC current-limiting response

provides close sizing on small motor and relay circuits, and
maximum component short-circuit current rating protection.

• 200kA interrupting rating provides high ratings for control 

circuit locations.

• Class CC rejection feature, with appropriate fuse block,

prevents inserting lesser-rated supplementary fuses.

• Inventory consolidation of 

13

32

x 1 

1

2

inch supplementary

fuses reduces SKU investment and minimizes potential for
misapplying fuse.

• Selective coordination ratio of 2:1 (within Low-Peak fuse

family) prevents electrical shutdowns from extending
beyond the failed circuit.

Typical Applications

• Specialized Circuits
• Industrial Control
• Isolated, In-Line Fuse Holder

Catalog Numbers (Amps)

LP-CC-

1

2

LP-CC-2-

1

2

LP-CC-7 

1

2

LP-CC-

6

10

LP-CC-2-

8

10

LP-CC-8

LP-CC-

8

10

LP-CC-3

LP-CC-9

LP-CC-1

LP-CC-3-

2

10

LP-CC-10

LP-CC-1-

1

8

LP-CC-3-

1

2

LP-CC-12

LP-CC-1-

1

4

LP-CC-4

LP-CC-15

LP-CC-1-

4

10

LP-CC-4-

1

2

LP-CC-20

LP-CC-1-

1

2

LP-CC-5

LP-CC-25

LP-CC-1-

6

10

LP-CC-5-

6

10

LP-CC-30

LP-CC-1-

8

10

LP-CC-6

LP-CC-2

LP-CC-6-

1

4

LP-CC-2-

1

4

LP-CC-7

Low-Peak

Time-delay, Rejection-Type Fuses

200

100

10

TIME IN SECONDS

1

.1

.01

/

/

¡º

°

/

¡º

1

1⁄

/

¢

3

3⁄

/

4

4⁄

/

6 8

10

12

15

20

25

30

AMP
RATING

.4

1

10

100

1000

CURRENT IN AMPS

Time Current Characteristics—Average Melt

Data Sheet: 1023

Recommended Fuse Holders & Blocks For Class CC Fuses

• See page 18

Current Limitation Curves

Low Voltage, Branch Circuit Rated Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

24

Low Voltage, Branch Circuit Rated Fuses

24

CC-Tron Rejection-type Fuses

Data Sheet: 1014

Specifications
Description:

Time-delay, branch circuit,

rejection-type fuse.

Dimensions:

13

32

˝ x 1 

1

2

˝ (10.3 x 38.1mm).

Ratings:

Volts — 600Vac (or less)

— 300Vdc (15-20A)

— 32Vdc (Self Certified)

Amps — 

1

4

-30A

IR — 200kA RMS Sym.

— 20kA DC (15 & 20A only)

Agency Information:

CE, Std. 248-4, Class CC, UL

Listed, Guide JDDZ, File E4273 CSA Certified,
Class 1422-01, File 53787.

Features and Benefits

• Time-delay compatible with inrush characteristic of small

control transformers.

• Current limitation at Class CC levels provides maximum

component short-circuit current rating protection.

• 200kA interrupting rating provides high ratings for control 

circuit locations.

• Class CC rejection feature, with appropriate fuse block,

prevents inserting lesser-rated supplementary fuses.

Typical Applications

• Line Protection, Small Control Transformers
• Industrial Control
• Isolated, In-Line Fuse Holders

Catalog Numbers (Amps)

FNQ-R-

1

4

FNQ-R-1-

6

10

FNQ-R-6

FNQ-R-

3

10

FNQ-R-1-

8

10

FNQ-R-6-

1

4

FNQ-R-

4

10

FNQ-R-2

FNQ-R-7

FNQ-R-

1

2

FNQ-R-2-

1

4

FNQ-R-7-

1

2

FNQ-R-

6

10

FNQ-R-2-

1

2

FNQ-R-8

FNQ-R-

3

4

FNQ-R-2-

8

10

FNQ-R-9

FNQ-R-

8

10

FQN-R-3

FNQ-R-10

FNQ-R-1

FNQ-R-3-

2

10

FNQ-R-12

FNQ-R-1-

1

8

FNQ-R-3-

1

2

FNQ-R-15

FNQ-R-1-

1

4

FNQ-R-4

FNQ-R-17-

1

2

FNQ-R-1-

3

10

FNQ-R-4-

1

2

FNQ-R-20

FNQ-R-1-

4

10

FNQ-R-5

FNQ-R-25

FNQ-R-1-

1

2

FNQ-R-5-

6

10

FNQ-R-30

AMP
RATING

100

10

1

0.01

0.08

1

10

100

200

CURRENT IN AMPS

300

400

500

TIME IN SECONDS

FNQ-R-1/2

FNQ-R-1

FNQ-R-3

FNQ-R-5

FNQ-R-7-1/2

0.01

Time-Current Characteristic Curves—Average Melt

FNQ-R Class CC

For superior electrical protection, Bussmann recommends upgrading FNQ-R
fuse applications to Low-Peak LP-CC fuses See page 17.

Recommended Fuse Holders & Blocks For Class CC

600V Fuses

• See page 18

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

25

Lo
w V

oltage

Branch Circuit

Fuses

25

Limitron

Rejection-type Fuses

Data Sheet: 1015

Specifications
Description:

Fast-acting, branch circuit,

rejection-type fuse.

Dimensions:

13

32

˝ x 1 

1

2

˝ (10.3 x 38.1mm).

Ratings:

Volts — 600Vac (or less)

Amps — 

1

10

-30A

IR — 200kA RMS Sym.

Agency Information:

CE, Std. 248-4,

Class CC, UL Listed, Guide JDDZ, File
E4273 CSA Certified, File 53787, Class 1422-02.

Features and Benefits

• Current limitation at Class CC levels provides maximum

component short-circuit current protection.

• 200kA interrupting rating provides high ratings for control 

circuit locations.

• Class CC rejection feature, with appropriate fuse block,

prevents inserting lesser-rated supplementary fuses.

Typical Applications

• Specialized Circuits
• Industrial Control
• Isolated, In-Line Fuse Holders (street lighting)

Catalog Numbers (Amps)

KTK-R-

1

10

KTK-R-1

KTK-R-7

KTK-R-

1

8

KTK-R-1-

1

2

KTK-R-8

KTK-R-

2

10

KTK-R-2

KTK-R-9

KTK-R-

1

4

KTK-R-2-

1

2

KTK-R-10

KTK-R-

3

10

KTK-R-3

KTK-R-12

KTK-R-

4

10

KTK-R-3-

1

2

KTK-R-15

KTK-R-

1

2

KTK-R-4

KTK-R-20

KTK-R-

6

10

KTK-R-5

KTK-R-25

KTK-R-

3

4

KTK-R-6

KTK-R-30

Time-Current Characteristic Curves—Average Melt

KTK-R Class CC

For superior electrical protection, Bussmann recommends upgrading KTK-R
fuse applications to Low-Peak LP-CC fuses See page 23.

Recommended Fuse Holders & Blocks For Class CC Fuses

• See page 18

Low Voltage, Branch Circuit Rated Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

26

Low Voltage, Branch Circuit Rated Fuses

26

Time-Delay Low-Peak CUBEFuse

Finger-safe Fuse and Fuse

Holder System

Data Sheet: 9000 (fuses) and 9007 (holders)     

Fuse Catalog Numbers Indicating (Amps)

TCF6

TCF25

TCF50

TCF100

TCF10

TCF30

TCF60

TCF15

TCF35

TCF70

TCF17-

1

2

TCF40

TCF80

TCF20

TCF45

TCF90

Fuse Catalog Numbers Non-Indicating (Amps)

TCF1RN

TCF17-

1

2

RN

TCF40RN

TCF80RN

TCF3RN

TCF20RN

TCF45RN

TCF90RN

TCF6RN

TCF25RN

TCF50RN

TCF100RN

TCF10RN

TCF30RN

TCF60RN

TCF15RN

TCF35RN

TCF70RN

TCF Class CF

Specifications
Description:

Finger-safe fuse and fuse holder system; 

dual-element, time-delay fuse; 10 seconds  minimum 
operating time at 500% rated amps.

Dimensions:

See Dimensions illustration.

Poles:

1-pole (gangable)

Ratings:

Volts — 600Vac (or less)

— 300Vdc (or less)

Amps — 1-100A

IR — 300kA RMS Sym. (UL)

— 200kA RMS Sym. (CSA)

— 100kA DC (UL & CSA)

Agency Information:

CE, UL Listed Guide JFHR, File

E4273, CSA Certified Fuse: Class 1422- 02, File 53787, UL
Listed Fuse holder: Guide IZND, File E214079, CSA
Certified Fuse holder: Class 6225-01, File 47235.

Features and Benefits

• Separate overload and short-circuit elements provide time

delay for sizing of high inrush loads linked with Class J 
current limitation.

• Selective coordination ratio of 2:1 (within Low-Peak fuse

family) prevents electrical shutdowns from extending
beyond the failed circuit.

• Smallest footprint of any Class CC, J, T or RK fuse 

provides substantial space savings and installation 
flexibility.

• IEC 60529 and finger-safe rating provides enhanced 

workplace safety.

Typical Applications

• Electrical Panelboards
• Machinery Disconnects
• Industrial Control
• Required Finger-Safe Systems

Available With

Indication

Amp

Carton

Weight Per Carton

Rating

Qty.

lbs

kg

TCF1-30A

12

1.39

0.63

TCF35-60A

12

1.42

0.65

TCF70-100A

6

1.74

0.79

Carton Quantity and Weight

Scan this tag to get the latest product

information for the TCF CUBEFuse.

Recommended Fuse Holders For Class CF Fuses

• See pages 32 and 33

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

27

27

Time-Current Characteristic Curves–Average Melt

Time-Delay Low-Peak CUBEFuse

Finger-safe Fuse and Fuse

Holder System

Dimensions for CUBEFuse Fuse and Fuse Holder

Current Limitation Curves

Data Sheet: 9000 (fuses) and 9007 (holders)     

Fuse

Dimensions - in (mm)

Amps

A

B

C

D

E

F

G

1-15

1.88

0.75

1.00

0.23

0.04

0.63

0.28

(47.75)

(19.05)

(25.40)

(5.84)

(1.02)

(15.93)

(7.11)

17 

1

2

1.88

0.75)

1.00

0.31

0.04

0.63

0.28

(47.75)

(19.05)

(25.40)

(7.87)

(1.02)

(15.93)

(7.11)

20

1.88

0.75)

1.00

0.31

0.04

0.63

0.28

(47.75)

(19.05)

(25.40)

(7.87)

(1.02)

(15.93)

(7.11)

25-30

1.88

0.75

1.00

0.31

0.04

0.63

0.28

(47.75)

(19.05)

(25.40)

(7.87)

(1.02)

(15.93)

(7.11)

35-40

2.13

1.00

1.13

0.36

0.04

0.63

0.38

(54.10)

(25.40)

(28.58)

(9.10)

(1.02)

(15.93)

(9.65)

45-50

2.13

1.00

1.13

0.44

0.04

0.63

0.38

(54.10)

(25.40)

(28.58)

(11.13)

(1.02)

(15.93)

(9.65)

60

2.13

1.00

1.13

0.44

0.04

0.63

0.38

(54.10)

(25.40)

(28.58)

(11.13)

(1.02)

(15.93)

(9.65)

70

3.01

1.00

1.26

0.49

0.06

0.58

0.38

(76.45)

(25.40)

(32.00)

(12.45)

(1.60)

(14.78)

(9.65)

80-90

3.01

1.00

1.26

0.49

0.06

0.58

0.38

(76.45)

(25.40)

(32.00)

(12.45)

(1.60)

(14.78)

(9.65)

100

3.01

1.00

1.26

0.57

0.06

0.58

0.38

(76.45)

(25.40)

(32.00)

(14.48)

(1.60)

(14.78)

(9.65)

Low Voltage, Branch Circuit Rated Fuses

Lo
w V

oltage

Branch Circuit

Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

28

Low Voltage, Branch Circuit Rated Fuses

UPS & Critical Application Fast-Acting CUBEFuse

Finger-safe Fuse

FCF Class CF Fuse

Carton Quantity and Weight

Amp

Carton Weight Per Carton

Rating

Qty.

lbs

kg

FCF-1-30A

12

1.39

0.63

FCF-35-60A

12

1.42

0.65

FCF-70-100A

6

1.74

0.79

Catalog Symbol:

FCF_RN

Fast-Acting Fuse:

4 minutes maximum clearing time at 200%

rated current for 1 to 30A fuse
6 minutes maximum clearing time at 200%
rated current for 35 to 60A fuse

Dimensions:

See Dimensions illustration.

Poles:

1-pole (gangable)

Ratings:

Volts — 600Vac (or less)

— 300Vdc (or less)

Amps — 1-100A

IR — 300kA RMS Sym. (UL)

— 200kA RMS Sym. (CSA)

— 50kA DC (UL & CSA)

Agency Information:

• UL Listed Fuse: Guide JFHR, File E4273
• CSA Certified Fuse: Class 1422- 02, File 53787
• CE compliance for the European Union low voltage directive

Other Ratings/Specifications:

Watts Loss at rated current:

FCF15RN: 3.48W
FCF30RN: 5.45W
FCF60RN: 7.27W

Operating and Storage Temperature Range:

-40 to 80°C

Material Specifications:

• Case: Glass filled PES (Polyethersulfone)
• Terminals: Copper alloy
• Terminal plating: Electroless tin

Data Sheet: 2147     

Features and Product Benefits

• The world’s first finger-safe power fuse system.

• Smallest footprint of any class fuse including Class J, CC, T

and RK.

• Class CF meets Class J fast-acting electrical 

performance requirements.

• Faster response to damaging faults to help reduce 

destructive thermal and magnetic forces.

• True fast-acting fuse construction.

• High interrupting rating to safely interrupt faults up to

300kA.

• No venting of arc or molten metal and gases during 

opening.

• Low let-through currents under fault conditions.

Fuse Catalog Numbers Non-Indicating (Amps)

FCF1RN

FCF20RN

FCF45RN

FCF90RN

FCF3RN

FCF25RN

FCF50RN

FCF100RN

FCF6RN

FCF30RN

FCF60RN

FCF10RN

FCF35RN

FCF70RN

FCF15RN

FCF40RN

FCF80RN

Scan this tag to get the latest product

information for the

New FCF CUBEFuse.

Recommended Fuse Holders For Class CF Fuses

• See pages 32 and 33

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

29

Lo
w V

oltage

Branch Circuit

Fuses

UPS & Critical Application Fast-Acting CUBEFuse

Finger-safe Fuse

Data Sheet: 2147     

FCF_RN Dimensions – in (mm)

Time-Current Characteristic Curves–Average Melt

Current Limitation Curves

100A

 

60A

 

10A

 

15A

 

20A

 

30A

 

40A

 

50A

 

1A

 

3A

 

6A

 

0.01 

0.1 

10 

100 

1000 

10 

100

 

1,000

 

10,000

 

TIME IN SECONDS 

CURRENT IN AMPS 

Fuse

Dimensions - in (mm)

Amps

A

B

C

D

E

F

G

1-15

1.88

0.75

1.00

0.23

0.04

0.63

0.28

(47.75)

(19.05)

(25.40)

(5.84)

(1.02)

(15.93)

(7.11)

20

1.88

0.75

1.00

0.31

0.04

0.63

0.28

(47.75)

(19.05)

(25.40)

(7.87)

(1.02)

(15.93)

(7.11)

25-30

1.88

0.75

1.00

0.31

0.04

0.63

0.28

(47.75)

(19.05)

(25.40)

(7.87)

(1.02)

(15.93)

(7.11)

35-40

2.13

1.00

1.13

0.36

0.04

0.63

0.38

(54.10)

(25.40)

(28.58)

(9.10)

(1.02)

(15.93)

(9.65)

45-50

2.13

1.00

1.13

0.44

0.04

0.63

0.38

(54.10)

(25.40)

(28.58)

(11.13)

(1.02)

(15.93)

(9.65)

60

2.13

1.00

1.13

0.44

0.04

0.63

0.38

(54.10)

(25.40)

(28.58)

(11.13)

(1.02)

(15.93)

(9.65)

70

3.01

1.00

1.26

0.49

0.06

0.58

0.38

(76.45)

(25.40)

(32.00)

(12.45)

(1.60)

(14.78)

(9.65)

80-90

3.01

1.00

1.26

0.49

0.06

0.58

0.38

(76.45)

(25.40)

(32.00)

(12.45)

(1.60)

(14.78)

(9.65)

100

3.01

1.00

1.26

0.57

0.06

0.58

0.38

(76.45)

(25.40)

(32.00)

(14.48)

(1.60)

(14.78)

(9.65)

A

30A

60A

15A

100A

100

1,000

10,000

100,000

100

1,000

10,000

100,000

INSTANTANEOUS 

PE

AK

 LET THRU CUR

RENT IN 

AM

PE

RES

PROSPECTIVE SHORT CIRCUIT CURRENT (SYMMETRICAL RMS AMPS)

B

300,000

Low Voltage, Branch Circuit Rated Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

30

Low Voltage, Branch Circuit Rated Fuses

Wind Fast-Acting CUBEFuse

– Finger-safe Fuse

WCF Class CF Fuse

Data Sheet: 9009     

Features and Product Benefits

• Maximize uptime and reliability using fuses designed and

listed to UL 248-1.

• Minimize chances of equipment failure and personnel injury

when using full range fuses having the industry’s fastest
response time to low-magnitude faults.

• Maximize return on investment with fuses proven to 

withstand harsh temperatures.

• Minimize design time, operating outage time and 

replacement cost with fuses qualified in excessively 
changing enviromental conditions.

• Simplify compatibility with readily available industry 

standard Class CF holders.

• Temperature Derating: Designed to maximize rated capacity

in elevated environmental temperatures.

• Overload Protection: Proven to clear faults faster than the

UL requirement.

• Power Loss: Minimal energy consumption leading to

increased efficiency.

Amp

Carton

Weight Per Carton

Rating

Qty.

lbs

kg

WCF1-30A

12

1.39

0.63

WCF35-60A

12

1.42

0.65

WCF70-100A

6

1.74

0.79

Carton Quantity and Weight

Catalog Numbers (amp rating)

Non-Indicating Wind CUBEFuse

WCF1RN

WCF15RN

WCF35RN

WCF60RN

WCF100RN

WCF3RN

WCF20RN

WCF40RN

WCF70RN

WCF6RN

WCF25RN

WCF45RN

WCF80RN

WCF10RN

WCF30RN

WCF50RN

WCF90RN

Catalog Symbol:

WCF_RN

Description: 

Finger-safe, fast-acting CUBEFuse for wind

power generation.

Electrical Characteristics:

Maximum clearing time at 200% 

rated current:

• 4 Minutes for 1 to 30A fuses
• 6 Minutes for 35 to 60A fuses
• 8 Minutes for 70 to 100A fuses

Agency Information:

• UL Recognized Fuse: Guide JFHR, File E56412
• cURus component certified C22.2
• CE compliance for the European Union low voltage 

directive

Other Ratings/Specifications:

Watts Loss at Rated Current:

WCF15RN: 3.48W
WCF30RN: 5.45W
WCF60RN: 7.27W

WCF100RN: 11.50W

Operating and Storage Temperature Range:

-40 to 90°C

Material Specifications:

• Case: Glass filled PES (Polyethersulfone)
• Terminals: Copper alloy

• Terminal plating: Electroless tin

Installation:

Fits 690V WCF holders as listed in the table

Application:

• Wind Systems:

- Transformer protection
- Pitch and speed control
- Turbine HVAC and lighting

Ratings:

Volts — 690Vac

Amps — 1-100A

IR — 50kA AC (1-60A)
IR — 30kA AC (70-100A)

Scan this tag to get the latest product

information for the

New WCF CUBEFuse.

Recommended Fuse Holders For Class CF Fuses

• See pages 32 and 33

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

31

Lo
w V

oltage

Branch Circuit

Fuses

Wind Fast-Acting CUBEFuse

– Finger-safe Fuse

WCF_RN Dimensions – in (mm)

Data Sheet: 2155     

Current Limitation Curves

60A 

100A 

40A 

50A 
35A 

100 

1,000 

10,000 

100,000 

100

 

1,000 

10,000

 

100,000

 

INSTANTANE

OUS 

PE

AK 

LE

T THRU CURRENT IN 

AMPS

 

PROSPECTIVE SHORT CIRCUIT CURRENT 

 SYMMETRICAL RMS AMPS  

300,000 

A

Fuse

Dimensions - in (mm)

Amps

A

B

C

D

E

F

G

35-40

2.13

1.00

1.13

0.36

0.04

0.63

0.38

(54.10)

(25.40)

(28.58)

(9.10)

(1.02)

(15.93)

(9.65)

45-50

2.13

1.00

1.13

0.44

0.04

0.63

0.38

(54.10)

(25.40)

(28.58)

(11.13)

(1.02)

(15.93)

(9.65)

60

2.13

1.00

1.13

0.44

0.04

0.63

0.38

(54.10)

(25.40)

(28.58)

(11.13)

(1.02)

(15.93)

(9.65)

70

3.01

1.00

1.26

0.49

0.06

0.58

0.38

(76.45)

(25.40)

(32.00)

(12.45)

(1.60)

(14.78)

(9.65)

80-90

3.01

1.00

1.26

0.49

0.06

0.58

0.38

(76.45)

(25.40)

(32.00)

(12.45)

(1.60)

(14.78)

(9.65)

100

3.01

1.00

1.26

0.57

0.06

0.58

0.38

(76.45)

(25.40)

(32.00)

(14.48)

(1.60)

(14.78)

(9.65)

Low Voltage, Branch Circuit Rated Fuses

Time-Current Characteristic Curves–Average Melt

100

A

60A

 

10A

 

15A

 

20A

 

30A

 

40A

 

50A

 

1A

 

3A

 

6A

 

0.01 

0.1 

10 

100 

1000 

10 

100

 

1,000

 

10,000

 

TIME

 IN

 SECONDS

 

CURRENT IN AMPS 

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Low Voltage, Branch Circuit Rated Fuses

32

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

CUBEFuse Fuse Holder

CUBEFuse

Finger-safe Fuse Holder System

Catalog Symbols:

Ampacity

600V

690V (Wind)

(holds any CUBEFuse)

TCFH30N

TCFH30NW

(1-30A)

TCFH60N

TCFH60NW

(1-60A)

TCFH100N

TCFH100NW

(1-100A)

Construction:

Finger-safe

Mounting:

35mm DIN-Rail or panel mount

Ratings:

Volts: 600V (UL, CSA)

690V (cURus - Wind version)

Withstand Rating: 300kA RMS Sym. (UL)

200kA RMS Sym. (CSA)
100kA DC (UL & CSA)
50kA AC (cURus, 1-60A Wind version)

Agency Information:

• UL Listed Fuse Holder: Guide IZLT, File E14853
• CSA Certified Fuse Holder: Class 6225-01, File 47235
• cURus component Certified
• CE compliance for the European Union low voltage directive

Operating and Storage Temperature Range:

-40 to 80°C

Material Specifications:

• Holder case: Glass filled PBT
• Interface clips: Copper alloy
• Interface clip plating: Tin
• Terminals: Steel
• DIN Rail spring: Stainless steel

Data Sheet: 9007     

CUBEFuse

CUBEFuse Type and Ampacity Range Per CUBEFuse Holder

Holder

Non-Indicating

Indicating

Catalog

Time-Delay

Time-Delay

Fast-Acting

Photovoltaic

Wind

Number

Volts

TCF_RN

TCF_

FCF_RN

PVCF_RN

WCF_RN

TCFH30N

600

1-30

6-30

1-30

TCFH60N

600

1-60

6-60

1-60

35-60

TCFH100N

600

1-100

6-100

1-100

35-100

TCFH30NW

690

1-30

TCFH60NW

690

1-60

TCFH100NW

690

1-100

CUBEFuse™ Holder Applications

Terminal Torque Ratings by Conductor and Holder Size (75°C Cu only)

TCFH30N / TCFH30NW

TCFH60N / TCFH60NW

TCFH100N / TCFH100NW

Single

Dual

Single

Dual

Single

Dual

10-8AWG 25Lb-In

18-10AWG 25Lb-In*

14-10AWG 20Lb-In

18-10AWG 20Lb-In

18-10AWG 25Lb-In**

6AWG 45Lb-In

18-12AWG 20Lb-In

8-4AWG 35Lb-In

8-6AWG 35Lb-In

8-1AWG 40Lb-In

* 18-10AWG Stranded, 14-18AWG solid

** Solid and stranded

† Stranded

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

33

Lo
w V

oltage

Branch Circuit

Fuses

Low Voltage, Branch Circuit Rated Fuses

Diamensions for CUBEFuse Fuse Holder

CUBEFuse

Finger-safe Fuse Holder System

Data Sheet: 9007     

Catalog

CUBEFuse

Wire Range (Cu/AWG)

Dimensions - in (mm)

Number

Amp Range

Single

Dual

H

I

J

K

L

M

TCFH30N

1-30

14-8

14-10

2.30

0.76

1.36

0.15

TCFH30NW

(58.5) (19.37) (34.24) (3.76)

TCFH60N

1-60

14-4

10-6

2.60

1.03

1.60

0.17

TCFH60NW

(66.12) (26.23) (40.64) (4.34)

TCFH100N

1-100

10-1

6

2.91

1.05

2.01

0.15

0.80

2.51

TCFH100NW

(73.81) (26.74) (50.93) (3.81) (20.39) (63.65)

CUBEFuse™ Holder Catalog Numbers

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

34

Low Voltage, Branch Circuit Rated Fuses

Time-delay Fuses

Data Sheet: 1024

Specifications
Description:

Fast-acting (

1

2

-6A), 

time-delay (7-60A)fuse.

Dimensions:

See dimensions 

illustration.

Ratings:

Volts — 600Vac (

1

2

-20A)

— 480Vac (25-60A)

— 170Vdc (

1

2

-20A)

— 300Vdc (30 & 60A only)

Amps — 

1

2

-60A

IR — 100kA RMS Sym.

— 10kA DC

Agency Information:

CE, Std. 248-

5, Class G, UL Listed, Guide JDDZ, File E4273, CSA
Certified, Class 1422-01, File 53787.

Features and Benefits

• Current limiting for component protection, providing Class G

energy-limitation for branch circuit protection.

• 100kA interrupting rating provides cost-effective branch 

circuit fusing.

• Variations in length help prevent overfusing.

Typical Applications

• Fusible Branch Panelboards
• HVAC Branch Circuit Protection

Catalog Numbers (Amps)

SC-

1

2

SC-2-

1

2

SC-6

SC-12

SC-30

SC-50

SC-1

SC-3

SC-7

SC-15

SC-35

SC-60

SC-1-

1

2

SC-4

SC-8

SC-20

SC-40

SC-2

SC-5

SC-10

SC-25

SC-45

SC Class G

Recommended Fuse Holders & Blocks For Class G Fuses

• See page 18

Dimensions -in (mm) 

Fuse Amps

Length

Diameter

SC-

1

2

to -15

1.31 (33.3)

0.41” (10.4)

SC-20

1.41 (35.8)

0.41” (10.4)

SC-25 to -30

1.62 (41.2)

0.41” (10.4)

SC-35 to -60

2.25 (57.1)

0.41” (10.4)

A

(Length)

0.41"

(10.41mm)

Current Limitation Curves

Time-Current Characteristic Curves—Average Melt

B

60

30
20
15

AMP

RA

TING

A

10,000

1,000

100

100

1,000

10,000

100,000

INST

ANT

ANEOUS PEAK LET

-THROUGH 

CURRENT

 IN 

AMPS

RMS SYMMETRICAL CURRENTS IN AMPS

A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

35

Lo
w V

oltage

Branch Circuit

Fuses

Low-Peak

Dual-element, Time-delay Fuses

LPJ_SP Class J

Available With

Indication

Specifications
Description:

Dual-element,
time-delay fuse; 
10 seconds (minimum) at 500% rated amps. Now
available with optional indication on select ratings
(see Catalog Numbers table).

Dimensions:

See page 11 for Class J dimensions.

Ratings:

Volts — 600Vac (or less)

— 300Vdc (or less)

Amps — 1-600A

IR — 300kA RMS Sym.

— 100kA DC

Agency Information:

CE, UL Listed - Special Purpose*,

Guide JFHR, File E56412, CSA Certified (200k AIR) Class J
per CSA-22.2 No. 248.8, Class 1422-02, File 53787.

Features and Benefits

• Separate overload and short-circuit elements provide time

delay for sizing of high inrush loads linked with Class J 
current limitation.

• Selective coordination ratio of 2:1 (within Low-Peak fuse

family) prevents electrical shutdowns from extending
beyond the failed circuit.

• Series combination ratings with branch circuit breakers

allows broad range of coverage, independent of breaker
manufacturer.

Typical Applications

• Power Panelboards
• Branch Circuit Breaker Panelboard Mains
• Machinery Disconnects
• Industrial Control

Catalog Numbers (Amps)

LPJ-1SP

LPJ-4-

1

2

SP

LPJ-25SP**

LPJ-125SP**

LPJ-1-

1

4

SP

LPJ-5SP

LPJ-30SP**

LPJ-150SP**

LPJ-1-

6

10

SP

LPJ-5-

6

10

SP

LPJ-35SP**

LPJ-175SP**

LPJ-1-

8

10

SP

LPJ-6SP**

LPJ-40SP**

LPJ-200SP**

LPJ-2SP

LPJ-7SP**

LPJ-45SP**

LPJ-225SP**

LPJ-2-

1

4

SP

LPJ-8SP**

LPJ-50SP**

LPJ-250SP**

LPJ-2-

1

2

SP

LPJ-9SP**

LPJ-60SP**

LPJ-300SP**

LPJ-2-

8

10

SP

LPJ-10SP**

LPJ-70SP**

LPJ-350SP**

LPJ-3SP

LPJ-12SP**

LPJ-80SP**

LPJ-400SP**

LPJ-3-

2

10

SP

LPJ-15SP**

LPJ-90SP**

LPJ-450SP**

LPJ-3-

1

2

SP

LPJ-17-

1

2

SP**

LPJ-100SP**

LPJ-500SP**

LPJ-4SP

LPJ-20SP**

LPJ-110SP**

LPJ-600SP**

*Meets all performance requirements of UL Standard 248-8 for Class J fuses.
**Available with optional permanent replace fuse indication. To order, place “I” at end of
catalog number. Example: LPJ-6SPI.
Available with silver plated terminals. Add SP/ in front of Catalog Number.

AMP
RATING

1A

3A

6A

300

100

10

1

.1

.01

TIME IN SECONDS

10A

15A

30A

60A

100A

400A

1,000

100

CURRENT IN AMPS

600A

125A

250A

200A

80A

200

10

10,000

1

Recommended Fuse Holders & Blocks For Class J Fuses

• See page 20

Time-Current Characteristic Curves–Average Melt

Current Limitation Curves

INST

ANT

ANEOUS PEAK LET

-THRU CURRENT

 IN 

AMPS

100,000

10,000

1,000

100

B

A

PROSPECTIVE SHORT-CIRCUIT CURRENT

SYMMETRICAL RMS AMPS

100

1,000

10,000

100,000

200,000

600A
400A

200A
100A
60A

30A

15A

RA

AMP

TING

LPJ Current Limitation Curves

300,000

Data Sheets: 1006 (0-60) and 1007 (70-600)

With indication 1062 (6-60) and 1063 (70-600)

Low Voltage, Branch Circuit Rated Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For superior electrical protection, Bussmann recommends upgrading JKS fuse
applications to Low-Peak LPJ fuses See page 35.

Recommended Fuse Holders & Blocks For Class J Fuses

• See page 20

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

36

Low Voltage, Branch Circuit Rated Fuses

Limitron

Fast-acting Fuses

Specifications
Description:

Fast-acting, cur-

rent-limiting fuse.

Dimensions:

See page 15 for

Class J dimensions.

Ratings:

Volts — 600Vac (or less)

Amps — 1-600A

IR — 200kA RMS Sym.

Agency Information:

CE, Std.

248-8, Class J, UL
Listed, Guide JDDZ,
File E4273, CSA
Certified, Class 1422-02, File 53787.

Features and Benefits

• Current limitation for non-inductive circuits provides Class J

current-limiting response to maximum ground fault and
short-circuit conditions.

• 200kA interrupting rating provides high ratings at all circuit

locations.

• Economical solutions for high-fault circuits.

Typical Applications

• Power Panelboards
• Machinery Disconnects

Catalog Numbers (Amps)

JKS-1

JKS-15

JKS-70

JKS-225

JKS-2

JKS-20

JKS-80

JKS-250

JKS-3

JKS-25

JKS-90

JKS-300

JKS-4

JKS-30

JKS-100

JKS-350

JKS-5

JKS-35

JKS-110

JKS-400

JKS-6

JKS-40

JKS-125

JKS-450

JKS-8

JKS-45

JKS-150

JKS-500

JKS-10

JKS-50

JKS-175

JKS-600

JKS-12

JKS-60

JKS-200

Data Sheet: 1026 (1-60) and 1027 (70-600)

JKS Class J

CURRENT IN AMPS

60A

100A

200A

30A

400A

AMP
RATING

600A

JKS

40

100

1,000

10,000

300

100

10

1

.1

.01

TIME IN SECONDS

600

400

200

AMP

RA

TING

100

INST

ANT

ANEOUS PEAK LET

-THRU CURRENT

 IN 

AMPS

1,000

10,000

100,000

200,000

400,000

100,000

10,000

1,000

RMS SYMMETRICAL CURRENTS IN AMPS

A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)

B

A

60

30

Time-Current Characteristic Curves—Average Melt

Current Limitation Curves

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

37

Lo
w V

oltage

Branch Circuit

Fuses

One-time General Purpose Fuses

Specifications
Description:

General purpose, 

non-current-limiting fuses.

Dimensions: 

See page 15 for 

dimensions.

Ratings:

Volts — 

NON:

— 250Vac

— 125Vdc (0-100A)

— 

NOS:

— 600Vac

Amps — 

1

8

-600A

IR — 50kA RMS Sym. (NON & NOS Class

K5 0-60A)

— 10kA RMS Sym. (NON & NOS Class H65-600A)

— 50kA @ 125Vdc (NON Class K5 0-60A)

— 10kA @ 125Vdc (NON Class H 65-100A)

Agency Information:

CE, UL Listed – 250V: Class K5

(0-60A), Std. 248-9, Class H (65-600A), Std. 248-6, (125Vdc:
NON 0-100), 600V: Class K5 (0-60A), Std. 248-9, Class H
(70-600A), Std. 248-6, Guide JDDZ, File E4273, CSA
Certified – 250V: (0-12, 65-600)†, 600V: (0-600), Class
1421-01, File 53787.

† 

For CSA Certified 15-60A Ratings, see PON Data Sheet 4126

Features and Benefits

• Original fuse providing circuit protection.

Typical Applications

• Light Duty Circuit Locations

NON (250Vac) Catalog Numbers (Amps)

NON-

1

8

NON-5

NON-40

NON-175

NON-

1

2

NON-6

NON-45

NON-200

NON-

3

4

NON-6-

1

4

NON-50

NON-225

NON-

8

10

NON-7

NON-60

NON-250

NON-1

NON-8

NON-65

NON-300

NON-1-

1

4

NON-9

NON-70

NON-350

NON-1-

1

2

NON-10

NON-75

NON-400

NON-1-

6

10

NON-12

NON-80

NON-450

NON-2

NON-15

NON-90

NON-500

NON-2-

1

2

NON-20

NON-100

NON-600

NON-3

NON-25

NON-110

NON-3-

2

10

NON-30

NON-125

NON-4

NON-35

NON-150

NOS (600Vac) Catalog Numbers (Amps)

NOS-1

NOS-12

NOS-70

NOS-200

NOS-2

NOS-15

NOS-75

NOS-225

NOS-3

NOS-20

NOS-80

NOS-250

NOS-4

NOS-25

NOS-90

NOS-300

NOS-5

NOS-30

NOS-100

NOS-350

NOS-6

NOS-35

NOS-110

NOS-400

NOS-7

NOS-40

NOS-125

NOS-450

NOS-8

NOS-45

NOS-150

NOS-500

NOS-9

NOS-50

NOS-175

NOS-600

NOS-10

NOS-60

Recommended Fuse Reducers

250V

600V

Fuse

Clip

Catalog

Fuse

Clip

Catalog

Amp

Amp

Number

Amp

Amp Number

Size

Size

(Pair)

Size

Size

(Pair)

30

60

NO.263

30

60

NO.663

30

100

NO.213

30

100

NO.216

60

100

NO.216

60

100

NO.616

60

200

NO.226

60

200

NO.626

100

200

NO.2621

100

200

NO.2621

100

400

NO.2641

100

400

NO.2641

200

400

NO.2642

200

400

NO.2642

100

600

NO.2661

100

600

NO.2661

200

600

NO.2662

200

600

NO.2662

400

600

NO.2664

400

600

NO.2664

Data Sheet: 1030

NON (250Vac/125Vdc) Class K5 & H

NOS (600Vac) Class K5 & H

For superior electrical protection, Bussmann recommends upgrading NON
(250Vac) and NOS (600Vac) fuse applications to Low-Peak LPN-RK (250Vac)
and LPS-RK (600Vac) fuses See page 41.

Recommended Fuse Holders & Blocks For Class K5 & H

250V & 600V Fuses

• See page 18

Low Voltage, Branch Circuit Rated Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

38

Low Voltage, Branch Circuit Rated Fuses

Low-Peak

Time-delay Fuses

Specifications
Description:

Time-delay fuse – 4 

seconds (minimum) at 500% rated amps.

Dimensions:

See page 16 for Class L

dimensions.

Ratings:

Volts — 600Vac (or less)

— 300Vdc (601-2000A)

Amps — 601-6000A 

(use KRP-CL for current ratings
under 601A)

IR — 300kA RMS Sym.

— 100kA DC

Agency Information:

CE, UL Listed-

Special Purpose (meets all performance
requirements of UL Standard 248-10 for Class L
fuses),Guide JFHR, File E56412, CSA Certified (200k AIR),
Class 1422-02, File 53787, Class L per CSA C22.2, No.
248.10.

Features and Benefits

• Time-delay of four seconds at five times rating allows closer

sizing on large motor loads combined with Class L current
limitation.

• Selective coordination ratio of 2:1 (within Low-Peak fuse

family) prevents electrical shutdowns from extending
beyond the failed circuit.

• Interrupting rating of 300kA RMS symmetrical provides 

adequate ratings without obsolescence for all electrical 
systems, big or small.

• Quality construction, using high-grade materials, provides

lower watts loss and operating temperatures with superior
arc quenching during current-limiting action.

Typical Applications

• Large Distribution Switchboards
• Power Panelboards
• Large Machinery Disconnects

Catalog Numbers (Amps)

KRP-C-601SP

KRP-C-1000SP KRP-C-1800SP KRP-C-3500SP

KRP-C-650SP

KRP-C-1100SP

KRP-C-1900SP KRP-C-4000SP

KRP-C-700SP

KRP-C-1200SP KRP-C-2000SP KRP-C-4500SP

KRP-C-750SP

KRP-C-1350SP KRP-C-2001SP KRP-C-5000SP

KRP-C-800SP

KRP-C-1400SP KRP-C-2400SP KRP-C-6000SP

KRP-C-801SP

KRP-C-1500SP KRP-C-2500SP

KRP-C-900SP

KRP-C-1600SP KRP-C-3000SP

Data Sheets: 1008 and 1009

KRP-C_SP Class L

Recommended Fuse Holders & Blocks For Class L Fuses

• See page 19

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

39

Lo
w V

oltage

Branch Circuit

Fuses

Low-Peak

Time-delay Fuses

1000,000

10,000

1,000

10,000

300,000

INST

ANT

ANEOUS PEAK LET

-THRU CURRENT

 IN 

AMPS

PROSPECITVE SHORT-CIRCUIT CURRENT

SYMMETRICAL RMS AMPS

100,000

100,000

6,000A
5,000A
4,000A
3,000A
2,500A
2,000A

1,600A

1,200A
800A
601A

A

AMP

RA

TING

B

1,000

300 

100 

10 

.1 

.01 

1,000 

10,000 

100,000 

200,000 

CURRENT  IN  AMPS

TIME IN SECONDS 

800A

 

1200A

 

1600A

 

2000A

 

2500A

 

3000A

 

4000A

 

5000A

 

6000A

 

AMP
RA TING 

Current Limitation Curves

Time-Current Characteristic Curves—Average Melt

KRP-CL Current-limiting, Time-delay
Fuses

Specifications
Description:

Current-limiting, time-delay fuse.

Dimensions:

See page 16 for Class L dimensions.

Ratings:

Volts — 600Vac (or less)

Amps — 225-600A

IR — 200kA RMS Sym.

Features and Benefits

• Time-delay of four seconds at five times rating allows closer

sizing inductive loads coupled with an equivalent Class L
current limitation.

• Class L case size for amp ratings from 225 to 600A allows

downsize fusing of large Class L fused switches for improved
circuit protection.

Typical Applications

• Large Distribution Switchboards
• Power Panelboards
• Machinery Disconnects

Catalog Numbers (Amps)

KRP-CL-225

KRP-CL-350

KRP-CL-500

KRP-CL-250

KRP-CL-400

KRP-CL-600

KRP-CL-300

KRP-CL-450

Data Sheets: 1008 and 1009

Data Sheet: 1016

Recommended Fuse Holders & Blocks For Class L Fuses

• See page 19

Low Voltage, Branch Circuit Rated Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

40

Low Voltage, Branch Circuit Rated Fuses

Limitron

Fuses

Specifications
Description:

Fast-acting, bolt-mount

fuse.

Dimensions:

See page 22 for Class L

dimensions.

Ratings:

Volts — 600Vac (or less)

Amps — 601-6000A

IR — 200kA RMS Sym.

Agency Information:

CE, Std. 248-10,

Class L, UL Listed, Guide JDDZ, File
E4273 CSA Certified, Class 1422-02, File 53787.

Features and Benefits

• 200kA interrupting rating provides high ratings at all 

circuit locations.

• Economical solutions for high-fault circuits.
• Quality construction using high-grade materials provides

lower watts loss and operating temperatures with superior
arc quenching during current-limiting action.

Typical Applications

• Large Distribution Switchboards
• Power Panelboards

Catalog Number (Amps)

KTU-601

KTU-1000

KTU-2001

KTU-650

KTU-1100

KTU-2400

KTU-700

KTU-1200

KTU-2500

KTU-750

KTU-1400

KTU-3000

KTU-800

KTU-1500

KTU-3500

KTU-801

KTU-1600

KTU-4000

KTU-850

KTU-1800

KTU-5000

KTU-900

KTU-2000

KTU-6000

Specifications
Description:

Time-delay, bolt-mount fuse

- 5 seconds (minimum) at 500% rated
amps. See KRP-CL for amp ratings below
601A.

Dimensions:

See page 22 for Class L

dimensions.

Ratings:

Volts — 600Vac (or less)

Amps — 601-4000A

IR — 200kA RMS Sym.

Agency Information:

CE, Std. 248-10,

Class L, UL Listed, Guide JDDZ, File E4273, CSA Certified,
CSA Class 1422-02, File 53787.

Features and Benefits

• 200kA interrupting rating provides high ratings at all circuit

locations.

• Economical solutions for high fault circuits.

Typical Applications

• Large Distribution Switchboards
• Power Panelboards
• Large Machinery Disconnects

Catalog Numbers (Amps)

KLU-601

KLU-1200

KLU-2500

KLU-650

KLU-1500

KLU-3000

KLU-700

KLU-1600

KLU-4000

KLU-800

KLU-1800

KLU-1000

KLU-2000

Data Sheet: 1010

Data Sheet: 1013

KTU Class L

KLU Class L

For superior electrical protection, Cooper Bussmann recommends upgrading
KLU fuse applications to Low-Peak KRP-C fuses See page 38.

Recommended Fuse Holders & Blocks For Class L Fuses

• See page 19

For superior electrical protection, Cooper Bussmann recommends upgrading
KTU fuse applications to Low-Peak KRP-C fuses See page 38.

Recommended Fuse Holders & Blocks For Class L Fuses

• See page 19

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

41

Lo
w V

oltage

Branch Circuit

Fuses

Typical Applications

• Large Distribution Switchboards
• Power Panelboards
• Motor Control Centers
• Machinery Disconnect Switches

LPN Catalog Numbers (Amps)

LPN-RK-

1

10

SP

LPN-RK-3-

1

2

SP

LPN-RK-60SP**

LPN-RK-

15

100

SP

LPN-RK-4SP

LPN-RK-70SP**

LPN-RK-

2

10

SP

LPN-RK-4-

1

2

SP

LPN-RK-80SP**

LPN-RK-

3

10

SP

LPN-RK-5SP

LPN-RK-90SP**

LPN-RK-

4

10

SP

LPN-RK-5-

6

10

SP

LPN-RK-100SP**

LPN-RK-

1

2

SP

LPN-RK-6SP

LPN-RK-110SP**

LPN-RK-

6

10

SP

LPN-RK-6-

1

4

SP

LPN-RK-125SP**

LPN-RK-

8

10

SP

LPN-RK-8SP

LPN-RK-150SP**

LPN-RK-1SP

LPN-RK-9SP

LPN-RK-175SP**

LPN-RK-1-

1

8

SP

LPN-RK-10SP

LPN-RK-200SP**

LPN-RK-1-

1

4

SP

LPN-RK-12SP

LPN-RK-225SP**

LPN-RK-1-

4

10

SP

LPN-RK-15SP

LPN-RK-250SP**

LPN-RK-1-

6

10

SP

LPN-RK-17-

1

2

SP

LPN-RK-300SP**

LPN-RK-1-

8

1

0

SP

LPN-RK-20SP

LPN-RK-350SP**

LPN-RK-2SP

LPN-RK-25SP

LPN-RK-400SP**

LPN-RK-2-

1

4

SP

LPN-RK-30SP

LPN-RK-450SP**

LPN-RK-2-

1

2

SP

LPN-RK-35SP**

LPN-RK-500SP**

LPN-RK-2-

8

10

SP

LPN-RK-40SP**

LPN-RK-600SP**

LPN-RK-3SP

LPN-RK-45SP**

LPN-RK-3-

2

10

SP

LPN-RK-50SP**

*Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses.
**Available with optional indication. To order, place “I” at end of Catalog Number. Example: 
LPN-RK-35SPI.
0-60A fuses available with Nickel plate option. (Ex: LPS-RK30SPNP) 70-600A fuses available
with Tin plate option.  Example: LPS-RK-100SP-TP.

LPS Catalog Numbers - (Amps)

LPS-RK-

1

10

SP

LPS-RK-2-

1

4

SP

LPS-RK-10SP**

LPS-RK-100SP**

LPS-RK-

2

10

SP

LPS-RK-2-

1

2

SP

LPS-RK-12SP**

LPS-RK-110SP**

LPS-RK-

3

10

SP

LPS-RK-2-

8

10

SP

LPS-RK-15SP**

LPS-RK-125SP**

LPS-RK-

4

10

SP

LPS-RK-3SP

LPS-RK-17-

1

2

SP**

LPS-RK-150SP**

LPS-RK-

1

2

SP

LPS-RK-3-

2

10

SP

LPS-RK-20SP**

LPS-RK-175SP**

LPS-RK-

6

10

SP

LPS-RK-3-

1

2

SP

LPS-RK-25SP**

LPS-RK-200SP**

LPS-RK-

8

10

SP

LPS-RK-4SP

LPS-RK-30SP**

LPS-RK-225SP**

LPS-RK-1SP

LPS-RK-4-

1

2

SP

LPS-RK-35SP**

LPS-RK-250SP**

LPS-RK-1-

1

8

SP

LPS-RK-5SP

LPS-RK-40SP**

LPS-RK-300SP**

LPS-RK-1-

1

4

SP

LPS-RK-5-

6

10

SP

LPS-RK-45SP**

LPS-RK-350SP**

LPS-RK-1-

4

10

SP

LPS-RK-6SP**

LPS-RK-50SP**

LPS-RK-400SP**

LPS-RK-1-

1

2

SP

LPS-RK-6-

1

4

SP**

LPS-RK-60SP**

LPS-RK-450SP**

LPS-RK-1-

6

10

SP

LPS-RK-7SP**

LPS-RK-70SP**

LPS-RK-500SP**

LPS-RK-1-

8

10

SP

LPS-RK-8SP**

LPS-RK-80SP**

LPS-RK-600SP**

LPS-RK-2SP

LPS-RK-9SP**

LPS-RK-90SP**

*Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses.

**Available with optional replace fuse indication. To order, place “I” at end of Catalog
Number. Example: LPS-RK-15SPI.

Low-Peak

Dual-element, Time-delay Fuses

LPN-RK_SP (250V) Class RK1

LPS-RK_SP (600V) Class RK1

Available With

Indication

Specifications
Description:

Current-limiting,
dual-element,
time-delay fuse; 10 seconds
(minimum) at 500% rated amps
(8 seconds for 0-30A sizes).
Now available with optional
indication on select ratings
(see Catalog Numbers table).

Dimensions:

See page 15 for

Class RK1 dimensions.

Ratings:

Volts

LPN-RK:

— 250Vac (or less)

— 125Vdc (0-60A)

— 250Vdc (70-600A)

LPS-RK:

— 600Vac (or less)

— 300Vdc

Amps — 

1

10

-600A

IR — 300kA RMS Sym.

— 100kA DC

Agency Information:

CE, UL Listed – Special Purpose*,

Guide JFHR, File E56412, CSA Certified (200k AIR), Class
RK1 per CSA C22.2, No. 248.12, Class 1422-02, File 53787.

Features and Benefits

• Separate overload and short-circuit elements provide time

delay for close sizing of high inrush loads linked with RK1
current-limitation and selective coordination ratio of 2:1
(within Low-Peak fuse family) prevents widespread
blackouts.

• Inventory consolidation of Class RK1, RK5 and H fuses for

reduced SKU investment and minimizing potential for
misapplying fuse.

• 300kA RMS symmetrical interrupting rating provides

adequate ratings without obsolescence for all electrical
systems, big or small.

• Insulated end caps reduces exposure to live parts and

extends air gap to distance between blades of adjacent
mounted fuses or to housing.

Data Sheets: LPN-RK — 1003 (0-60) and 1004 (70-600)

LPN-RK with indication — 1066 (70-600)
LPS-RK — 1001 (0-60) and 1002 (70-600)
LPS-RK with indication — 1061 (0-60) and
1064 (70-600)

Recommended Fuse Holders & Blocks For Class RK1 Fuses

• See page 19

Low Voltage, Branch Circuit Rated Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

42

Low Voltage, Branch Circuit Rated Fuses

Low-Peak

Dual-element, Time-delay Fuses

Time-Current Characteristic Curves—Average Melt

TIME IN SECONDS

CURRENT IN AMPS

AMP RATING

300

100

10

1

.1

.01

20

100

1,000

10,000     

15 20  30        60      100

200    400  600

LPN-RK 

TIME IN SECONDS

CURRENT IN AMPS

AMP RATING

300

100

10

1

.1

.01

20

100

1,000

10,000     

20   30      60     100

200    400  600

LPS-RK 

4  5 

8  10  12 

AMP RATING

300 

100 

10 

.1 

.01 

.1 

10 

100 

1,000 

TIME IN SECONDS 

RMS SYMMETRICAL CURRENT IN AMPS

1

/

10 

15

/

100 

2

/

10 

3

/

10 

4

/

10 

1

/

6

/

10 

8

/

10 

1

1

/

1

6

/

10 

2

1

/

3

2

/

10 

6

1

/

LPN-RK

1

/

10

15

/

100

2

/

10

4

/

10

6

/

10

1

6

/

10

8

/

10

1

2

4 5

8

12

10

1

1

/

4

2

1

/

2

3

2

/

10

6

1

/

4

1

/

2

3

/

10

LPS-RK 

TIME IN SECONDS

CURRENT IN AMPS

AMP RATING

Data Sheets: LPN-RK — 1003 (0-60) and 1004 (70-600)
Data Sheets: LPS-RK — 1001 (0-60) and 1002 (70-600)

Recommended Fuse Holders & Blocks For Class RK1 Fuses

• See page 19

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

43

Lo
w V

oltage

Branch Circuit

Fuses

A

B

600
400

200

100

AMP RA

TING

400,000

100,000

10,000

1,000

1,000

10,000

100,000

200,000

RMS SYMMETRICAL CURRENTS IN AMPS

A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) 

INST

ANT

ANEOUS PEAK LET

-THRU CURRENT

 IN 

AMPS

60

30

Current Limitation Curves—LPN-RK

B

INST

ANT

ANEOUS PEAK LET

-THRU CURRENT

 IN 

AMPS

Current Limitation Curves—LPS-RK

Data Sheets: LPN-RK — 1003 (0-60) and 1004 (70-600)
Data Sheets: LPS-RK — 1001 (0-60) and 1002 (70-600)

Recommended Fuse Holders & Blocks For Class RK1 Fuses

• See page 19

Low-Peak

Dual-element, Time-delay Fuses

Low Voltage, Branch Circuit Rated Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

44

Low Voltage, Branch Circuit Rated Fuses

Limitron

Fast-acting Fuses

Data Sheet: 1043

Specifications
Description:

Fast-acting, current-limiting

fuse.

Dimensions:

See page 21 for Class RK1

dimensions.

Ratings:

Volts — 250Vac (or less)

Amps — 1-600A

IR — 200kA RMS Sym.

Agency Information:

CE, Std. 248-12,

Class RK1, UL Listed, Guide JDDZ, File
E4273, CSA Certified, Class 
1422-02, File 53787.

Features and Benefits

• Current limitation for non-inductive circuits provides Class

RK1 current-limiting response to maximum ground fault and
short-circuit conditions.

• 200kA interrupting rating provides high ratings at all circuit

locations.

• Economical solutions for high-fault circuits.

Typical Applications

• Panelboards

Catalog Numbers (Amps)

KTN-R-1

KTN-R-30

KTN-R-125

KTN-R-2

KTN-R-35

KTN-R-150

KTN-R-3

KTN-R-40

KTN-R-175

KTN-R-4

KTN-R-45

KTN-R-200

KTN-R-5

KTN-R-50

KTN-R-225

KTN-R-6

KTN-R-60

KTN-R-250

KTN-R-8

KTN-R-70

KTN-R-300

KTN-R-10

KTN-R-75

KTN-R-350

KTN-R-12

KTN-R-80

KTN-R-400

KTN-R-15

KTN-R-90

KTN-R-450

KTN-R-20

KTN-R-100

KTN-R-500

KTN-R-25

KTN-R-110

KTN-R-600

Time-Current Characteristic Curves—Average Melt

Current Limitation Curves

KTN-R (250V) Class RK1

For superior electrical protection, Bussmann recommends upgrading KTN-R
fuse applications to Low-Peak LPN-RK fuses See page 41.

Recommended Fuse Holders & Blocks For Class RK1 Fuses

• See page 19

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

45

Lo
w V

oltage

Branch Circuit

Fuses

Low Voltage, Branch Circuit Rated Fuses

Limitron

Fast-acting Fuses

Data Sheet: 1044

Specifications
Description:

Fast-acting, current-limiting

fuse.

Dimensions:

See page 21 for Class RK1

dimensions.

Ratings:

Volts — 600Vac (or less)

Amps — 1-600A

IR — 200kA RMS Sym.

Agency Information:

CE, Std. 248-12,

Class RK1, UL Listed, Guide JDDZ, File
E54273, CSA Certified, C22.2 No. 248.12, Class 
1422-02, File 53787.

Features and Benefits

• Current limitation for non-inductive circuits provides Class

RK1 current-limiting response to maximum ground fault and
short-circuit conditions.

• 200kA interrupting rating provides high ratings at all circuit

locations.

• Economical solutions for high-fault circuits.

Typical Applications

• Panelboards

Catalog Numbers (Amps)

KTS-R-1

KTS-R-30

KTS-R-125

KTS-R-2

KTS-R-35

KTS-R-150

KTS-R-3

KTS-R-40

KTS-R-175

KTS-R-4

KTS-R-45

KTS-R-200

KTS-R-5

KTS-R-50

KTS-R-225

KTS-R-6

KTS-R-60

KTS-R-250

KTS-R-8

KTS-R-70

KTS-R-300

KTS-R-10

KTS-R-75

KTS-R-350

KTS-R-12

KTS-R-80

KTS-R-400

KTS-R-15

KTS-R-90

KTS-R-450

KTS-R-20

KTS-R-100

KTS-R-500

KTS-R-25

KTS-R-110

KTS-R-600

KTS-R (600V) Class RK1

For superior electrical protection, Bussmann recommends upgrading KTN-R
fuse applications to Low-Peak LPN-RK fuses See page 41.

Recommended Fuse Holders & Blocks For Class RK1 Fuses

• See page 19

600

100

60

AMPERE

RA

TING

30

400

200

200,000

100,000

10,000

1,000

1,000

INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS

400,000

100,000

10,000

RMS SYMMETRICAL CURRENTS IN AMPERES

A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 x SYMM RMS  AMPS)

B

A

Current-Limitation Curves

RMS SYMMETRICAL CURRENT IN AMPERES

TIME IN SECONDS

300

100

10

1

.1

.01

40

100

1,000

10,000

30A

60A

100A

200A

400A

600A

AMPERE
RATING

Time-Current Characteristic Curves–Average Melt

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

46

Low Voltage, Branch Circuit Rated Fuses

60

100

200

400

600

30

15

10

8

Time-Current Characteristic Curves—Average Melt

Fusetron

Energy Efficient, Dual-element, Time-delay Fuses

Specifications
Description:

Dual-element, time-delay

fuse – 10 seconds (minimum) at 500%
rated amps (8 seconds for 0-30A sizes).
Available with indication on select ratings
(see Catalog Numbers table).

Dimensions:

See page 15 for Class RK5

dimensions.

Ratings:

Volts — 250Vac (or less)

— 125Vdc (

1

10

-60A, 110-200A)

— 250Vdc (225-600A)

Amps — 

1

10

-600A

IR — 200kA RMS Sym.

— 20kA DC

Agency Information:

CE, Std. 248-12, Class RK5, 

UL Listed, Guide JDDZ, File E4273, CSA Certified, Class
1422-01, File 53787.

Features and Benefits

• Separate overload and short-circuit elements provide time

delay for sizing as close as 125% of motor FLA. 

• 2:1 selective coordination amp ratio (within the Cooper

Bussmann RK5 fuse family) prevents overcurrent events
from opening upstream Fusetron fuses.

• Insulated end caps for 225A-600A fuses reduces exposure

to live parts and extends air gap to distance between
blades of adjacent mounted fuses or to housing.

Typical Applications

• Power Panelboards
• Motor Control Centers

Catalog Numbers (Amps)

FRN-R-

1

10

FRN-R-2

FRN-R-10*

FRN-R-100

FRN-R-

1

8

FRN-R-2-

1

4

FRN-R-12*

FRN-R-110

FRN-R-

15

100

FRN-R-2-

1

2

FRN-R-15*

FRN-R-125

FRN-R-

2

10

FRN-R-2-

8

10

FRN-R-17-

1

2

*

FRN-R-150

FRN-R-

1

4

FRN-R-3

FRN-R-20*

FRN-R-175

FRN-R-

3

10

FRN-R-3-

2

10

FRN-R-25*

FRN-R-200

FRN-R-

4

10

FRN-R-3-

1

2

FRN-R-30*

FRN-R-225

FRN-R-

1

2

FRN-R-4

FRN-R-35*

FRN-R-250

FRN-R-

6

10

FRN-R-4-

1

2

FRN-R-40*

FRN-R-300

FRN-R-

8

10

FRN-R-5

FRN-R-45*

FRN-R-350

FRN-R-1

FRN-R-5-

6

10

FRN-R-50*

FRN-R-400

FRN-R-1-

1

8

FRN-R-6

FRN-R-60*

FRN-R-450

FRN-R-1-

1

4

FRN-R-6-

1

4

FRN-R-70

FRN-R-500

FRN-R-1-

4

10

FRN-R-7

FRN-R-75

FRN-R-600

FRN-R-1-

1

2

FRN-R-7-

1

2

FRN-R-80

FRN-R-1-

6

10

FRN-R-8*

FRN-R-85

FRN-R-1-

8

10

FRN-R-9*

FRN-R-90

Data Sheets: 1019 (

1

10

-60) and 1020 (70-600)

Data Sheet: 1169 (8-60) FRN-R with indication

Instantaneous Peak Let-Through Current Amps

 

RMS Symmetrical Currents In Amps

A–B = Asymmetrical Available Peak (2.3 x Sym RMS Amps)

400,000

100,000

10,000

1,000

1,000

10,000

100,000

200,000

60

600

100

Amp

Rating

400

200

B

A

30

FRN-R

Current Limitation Curves

FRN-R (250V) Class RK5

*Available with indication. To order, place “ID” at the end of the catalog number.
Example: FRN-R-30ID

• Combination Starters
• Machinery Disconnects

Recommended Fuse Reducers For Class R Fuses

• See page 20

For superior electrical protection, Bussmann recommends upgrading FRN-R fuse
applications to Low-Peak LPN-RK fuses. See page 41.

Recommended Fuse Holders & Blocks For Class RK5 Fuses

• See page 19

Available

With

Indication

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

47

Lo
w V

oltage

Branch Circuit

Fuses

Fusetron

Energy Efficient, Dual-element, Time-delay Fuses

600A

100A

Amp 

Rating

400A

200A

60A

Instantaneous Peak Let-Through Current 

Amps

 

RMS Symmetrical Currents In Amps

A–B = Asymmetrical Available Peak (2.3 x Sym RMS Amps)

B

A

400,000

100,000

10,000

1,000

1,000

10,000

100,000

FRS-R (600V)

30A

200,000

15A

Time-Current Characteristic Curves—Average Melt

Current Limitation Curves

FRS-R (600V) Class RK5

Specifications

Description:

Dual-element, time-delay fuse – 10

seconds (minimum) at 500% rated amps. Now
available with optional indication on select ratings
(see Catalog Numbers table).

Dimensions:

See page 15 for Class RK5 dimensions.

Ratings:

.

Agency Information:

CE, Std. 248-12, 

Class RK5, UL Listed, Guide JDDZ, File E4273, CSA
Certified, Class 1422-02, File 53787.

Features and Benefits

• 2:1 selective coordination ratio (within RK5 fuse family)

prevents electrical shutdowns from extending beyond the
failed circuit.

• Insulated end caps for 65-600A fuses reduces exposure to

live parts and extends air gap to distance between blades
of adjacent mounted fuses or to housing.

Typical Applications

• Power Panelboards
• Motor Control Centers

Catalog Numbers (Amps)

FRS-R-

1

10

FRS-R-2

FRS-R-10*

FRS-R-100

FRS-R-

1

8

FRS-R-2-

1

4

FRS-R-12*

FRS-R-110

FRS-R-

15

100

FRS-R-2-

1

2

FRS-R-15*

FRS-R-125

FRS-R-

2

10

FRS-R-2-

8

10

FRS-R-17-

1

2

*

FRS-R-150

FRS-R-

1

4

FRS-R-3

FRS-R-20*

FRS-R-175

FRS-R-

3

10

FRS-R-3-

2

10

FRS-R-25*

FRS-R-200

FRS-R-

4

10

FRS-R-3-

1

2

FRS-R-30*

FRS-R-225

FRS-R-

1

2

FRS-R-4

FRS-R-35*

FRS-R-250

FRS-R-

6

10

FRS-R-4-

1

2

FRS-R-40*

FRS-R-300

FRS-R-

8

10

FRS-R-5

FRS-R-45*

FRS-R-350

FRS-R-1

FRS-R-5-

6

10

FRS-R-50*

FRS-R-400

FRS-R-1-

1

8

FRS-R-6*

FRS-R-60*

FRS-R-450

FRS-R-1-

1

4

FRS-R-6-

1

4

*

FRS-R-65

FRS-R-500

FRS-R-1-

4

10

FRS-R-7*

FRS-R-70

FRS-R-600

FRS-R-1-

1

2

FRS-R-7-

1

2

*

FRS-R-75

FRS-R-1-

6

10

FRS-R-8*

FRS-R-80

FRS-R-1 

8

10

FRS-R-9*

FRS-R-90

Data Sheet: 1017 (

1

10

-60), 1018 (65-600)

Data Sheet: 1070 (6-60) FRS-R with Indication

For superior electrical protection, Bussmann recommends upgrading FRS-R fuse 
applications to Low-Peak LPS-RK fuses. See page 41.

Recommended Fuse Holders & Blocks For Class RK5 Fuses

• See page 19

Recommended Fuse Reducers For Class R Fuses

• See page 20

• Combination Starters
• Machinery Disconnects

*Available with indication. To order, place “ID” at the end of the catalog number. 
Example: FRS-R-7ID.

Available

With

Indication

Volts — 600Vac (or less)

Amps — 

1

10

-30A

IR — 200kA RMS Sym.

— 20kA @300Vdc

Amps — 35-60A

IR — 200kA RMS Sym.

— 20kA @250Vdc

Amps — 65-600A

IR — 200kA RMS Sym.

— 20kA @250Vdc

Low Voltage, Branch Circuit Rated Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

48

Low Voltage, Branch Circuit Rated Fuses

T-Tron

Fast-acting Fuses

Data Sheet: 1025

Specifications
Description:

Fast-acting, 

current-limiting fuse.

Dimensions:

See page 16 for Class T

dimensions.

Ratings:

Volts — 300Vac (or less)

— 160Vdc (15-600A)

— 170Vdc (601-1200A)

Amps — 1-1200A

IR — 200kA RMS Sym.

— 20kA DC @ 160Vdc

— 100kA DC @ 170Vdc

Agency Information:

CE, Std. 248-15, Class T, UL Listed,

Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File
53787.

Features and Benefits

• Series combination ratings with branch circuit breakers

allows broad range of coverage, independent of breaker
manufacturer.

• Current limitation for non-inductive circuits provides Class T

current-limiting response to maximum ground fault and
short-circuit conditions.

• 200kA interrupting rating provides high ratings at all

circuit locations.

• Small footprint allows more efficient use of available space.

Typical Applications

• Large Apartment Complexes
• Multi-Family Meter Stacks
• VFD Line Protection

Catalog Numbers (Amps)

JJN-1

JJN-15

JJN-40

JJN-80

JJN-150

JJN-300

JJN-600

JJN-2

JJN-20

JJN-45

JJN-90

JJN-175

JJN-350

JJN-700

JJN-3

JJN-25

JJN-50

JJN-100

JJN-200

JJN-400

JJN-800

JJN-6

JJN-30

JJN-60

JJN-110

JJN-225

JJN-450

JJN-1000

JJN-10

JJN-35

JJN-70

JJN-125

JJN-250

JJN-500

JJN-1200

JJN Class T

Current Limitation Curves

JJN

Time-Current Characteristic Curves—Average Melt

Recommended Fuse Holders & Blocks For Class T Fuses

• See page 19

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

49

Lo
w V

oltage

Branch Circuit

Fuses

Low Voltage, Branch Circuit Rated Fuses

Specifications
Description:

Very fast-acting, 

current-limiting fuse.

Dimensions:

See page 16 for Class T

dimensions.

Ratings:

Volts — 600Vac (or less)

Amps — 1-800A

IR — 200kA RMS Sym.

Agency Information:

CE, Std. 248-15, Class T, UL Listed,

Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File
53787.

Features and Benefits

• Series combination ratings with branch circuit breakers

allows broad range of coverage, independent of breaker
manufacturer.

• Current limitation for non-inductive circuits provides Class T

current-limiting response to maximum ground fault and
short-circuit conditions.

• 200kA interrupting rating provides high ratings at all

circuit locations.

• Small footprint allows more efficient use of available space.

Typical Applications

• Large Apartment Complexes
• Multi-Family Meter Stacks
• VFD Line Protection

Catalog Numbers (Amps)

JJS-1

JJS-15

JJS-40

JJS-80

JJS-150

JJS-300

JJS-600

JJS-2

JJS-20

JJS-45

JJS-90

JJS-175

JJS-350

JJS-800

JJS-3

JJS-25

JJS-50

JJS-100

JJS-200

JJS-400

JJS-6

JJS-30

JJS-60

JJS-110

JJS-225

JJS-450

JJS-10

JJS-35

JJS-70

JJS-125

JJS-250

JJS-500

Data Sheet: 1029

JJS Class T

T-Tron

Fast-acting Fuses

JJS

JJS

Time-Current Characteristic Curves—Average Melt

Recommended Fuse Holders & Blocks For Class T Fuses

• See page 19

Current Limitation Curves

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

50

Low Voltage, Branch Circuit Rated Fuses

Plug Fuses

Data Sheets: 1033 (SL) & 1035 (TL)

Specifications
Description:

Fast-acting plug

fuse.

Dimensions:

Edison base plug.

Construction:

Brass threads

with plastic body.

Ratings:

Volts — 125Vac

Amps — 

1

2

-12A

IR — 10kA RMS Sym.

Agency Information:

CE, Std. 248-11, UL Listed, Guide

JEFV, File E12112.

Features and Benefits

• Dependable, fast-acting circuit protection with 10kA

interrupting rating for added safety when applied to existing
plug fuse systems and 125-volt single-phase control
circuits.

Typical Applications

• Replacement only in existing systems.
• For general purpose circuit protection.
• Use for lighting and other non-motor circuits.

Catalog Numbers* (Amps)

W-

1

2

W-2 

1

2

W-6

W-10

W-1

W-3

W-6 

1

2

W-12

W-1 

8

10

W-4

W-7

W-DUMMY**

W-2

W-5

W-8

*W-15, W-20, W-25, and W-30 plug fuses obsoleted. Suggest replacing with either T-(Amp)
or TL-(Amp) plug fuses.

** Non-conductive dummy base. Not a fuse.

Specifications
Description:

Time-delay,

loaded link plug fuse.

Dimensions:

SL — Rejection base

TL — Edison base

Construction:

SL — Plastic base with rejection threads

TL — Brass threads with plastic body

Ratings:

Volts — 125Vac

Amps — 15-30A

IR — 10kA RMS Sym.

Agency Information:

CE, Std. 248-11, UL Listed, Guide

JEFV, File E12112.

Features and Benefits

• Time-delay loaded link TL Series Edison base plug fuses

pass motor overload starting currents without opening and
allow closer sizing to motor load for added protection.

• Time-delay loaded link SL Series fuses provide a rejection

feature (when used alone or with Fustat adapters to retrofit
Edison base holders) to help prevent overfusing.

Typical Applications

• Small motor and inductive load circuits with high in-rush

current levels.

• Used with box cover units to provide equipment protection.
• Applications benefiting from fuse rejection (SL Series only).

SL Catalog Numbers (Amps)

SL-15

SL-20

SL-25

SL-30

TL Catalog Numbers (Amps)

TL-15

TL-20

TL-25

TL-30

W Series

SL and TL Series

Recommended Fuse Holders For W Series Plug Fuses

• See page 20

Recommended Fuse Holders For SL & TL Series Plug Fuses

• See page 20
• See page 52 for Fustat adapters for use with SL Series

Data Sheet: 1036

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

51

Lo
w V

oltage

Branch Circuit

Fuses

Low Voltage, Branch Circuit Rated Fuses

S and T Series

Specifications
Description:

Dual-element, time-delay plug

fuse.

Dimensions:

S — Rejection base

T — Edison base

Construction:

S — Plastic base with rejection threads

T — Brass threads with plastic body

Ratings:

Volts — 125Vac

Amps — S Series: 

1

4

-30A

— T Series: 

3

10

-30A

IR — 10kA RMS Sym.

Agency Information:

CE, Std. 248-11, Type S and T: 

UL Listed (0-6

1

4

) Guide JFHR, File E56412 (7-30A) Guide

JEFV, File E12112; CSA Certified, Class 1423-01, File
53787.

Features and Benefits

• Time-delay, dual-element T Series Edison base plug fuses

provide small motor overload protection when used with
box cover units.

• Time-delay, dual-element S Series plug fuses provide a

rejection feature (when used alone or with Fustat adapters
to retrofit Edison base holders) to prevent overfusing of
branch circuits.

Typical Applications

• S Series — Residential Load Centers
• T Series — Box Cover Units for small motor overload 

protection

• Applications benefiting from fuse rejection (S Series only)

S Series Catalog Numbers (Amps)

S-

1

4

S-

8

10

S-1-

6

10

S-2-

1

2

S-4

S-7

S-14

S-

3

10

S-1

S-1-

8

10

S-2-

8

10

S-4-

1

2

S-8

S-15

S-

4

10

S-1-

1

8

S-2

S-3

S-5

S-9

S-20

S-

1

2

S-1-

1

4

S-2-

1

4

S-3-

2

10

S-6

S-10

S-25

S-

6

10

S-1-

4

10

S-5-

6

10

S-3-

1

2

S-6-

1

4

S-12

S-30

T Series Catalog Numbers (Amps)

T-

3

10

T-1-

1

8

T-2-

1

4

T-4

T-7

T-15

T-

4

10

T-1-

1

4

T-2-

1

2

T-4-

1

2

T-8

T-20

T-

1

2

T-1-

4

10

T-2-

8

10

T-5

T-9

T-25

T-

6

10

T-1-

6

10

T-3

T-5-

6

10

T-10

T-30

T-

8

10

T-1-

8

10

T-3-

2

10

T-6

T-12

T-1

T-2

T-3-

1

2

T-6-

1

4

T-14

Data Sheet: 1032 (S) & 1034 (T)

Recommended Fuse Holders For S & T Series Plug Fuses

• See page 20
• See page 52 for Fustat adapters for use with S Series

P & TC Series

Specifications
Description:

P Series  - Type P dual-element fuse

TC  Series - Type D dual-element, 
time-delay fuse 

Dimensions:

Edison base

Construction:

Brass threads with plastic

body.

Ratings:

Volts — 125Vac or less

Amps — 15-30A

IR — 10kA

Agency Information:

P Series - CSA Certified

TC Series - CSA Certified (Class 1423-01, File # 53787)

Features and Benefits

P Series

• “P” Rating for Canadian applications.
• Non-time delay for non-inductive loads

TC Series

• “D” Rating for Canadian applications
• Heavy duty TC fuses are industrial strength products, 

featuring dual-element construction.

• This spring loaded design provides superior short-circuit 

and overload protection.

• The TC fuses have more time-delay than the medium 

duty fuses in order to better protect industrial motors and 
residential circuits. 

Typical Applications

• P Series — Non-inductive loads, residential load centers
• TC Series — Box Cover Units for small motor overload 

protection

P Series Catalog Numbers (Amps)

P-15

P-20

P-25

P-30

TC Series Catalog Numbers (Amps)

TC-15

TC-20

TC-25

TC-30

Data Sheet: 1039 (TC Series only)

Recommended Fuse Holders For P & TC Series Plug Fuses

• See page 20
• See page 52 for Fustat adapters for use with S Series

Plug Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

52

Low Voltage, Branch Circuit Rated Fuses

Plug Fuses

Specifications
Description:

Edison base manual reset circuit breakers.

Dimensions:

Edison base

Construction:

Brass threads with plastic body

Ratings:

Volts — 125Vac only

Amps — 15-20A

IR — 10kA RMS Sym.

Agency Information: 

UL Listed, File E14942

Features and Benefits

• Fit standard Edison base fuse receptacles.
• Resettable upon overload event.

Typical Applications*

• Replacing Edison base plug fuses in residential fuse panels.

Catalog Numbers* (Amps)

MB-15
MB-20

* Not for use in box cover units or for inductive loads.

MB Edison Base Circuit Breakers

Specifications
Description:

Adapters for using Type S and SL rejection

fuses in Edison base fuse sockets.

Agency Information: 

UL Listed, File E12853; CSA

Certified File #6225-01, File #47235.

Features and Benefits

• Fustat adapters screw into the “Edison” thread fuse sockets

of standard fuse boxes making it easy to retrofit existing
fuse installations

• Available in various amp ratings to cover a wide range of

rating requirements

Typical Applications

• Plug fuse installations where it is desirable to restrict fuse

amp ratings

Catalog Numbers (Amps)

SA-1*

SA-3-

2

10

*

SA-10*

SA-1-

1

4

*

SA-4*

SA-15**

SA-1-

6

10

*

SA-5*

SA-20**

SA-2*

SA-6-

1

4

*

SA-30**

SA-2-

1

2

*

SA-8*

* Single motor circuits.
** Branch circuits.

Fustat

®

Adapters for Small Motor Protection*

Adapter

Accepts Fuses

SA-1

S-1 or smaller

SA-1-

1

4

S-1-

1

4

or smaller

SA-1-

6

10

S-1-

6

10

or smaller

SA-2

S-2 or S-1-

8

10

SA-2-

1

2

S-2-

1

2

to S-1-

8

10

SA-3-

2

10

S-3-

2

10

to S-1-

8

10

SA-4

S-4 to S-3-

1

2

SA-5

S-5 to S-3-

1

2

SA-6-

1

4

S-6-

1

4

to S-3-

1

2

SA-8

S-8 to S-7

SA-10

S-10 to S-7

SA-15

S-15 to S-7

SA-20

S-20

SA-30

S-30 to S-20

* Both motor running and short-circuit protection.

Fustat

®

Adapters for Branch Circuit Protection

Adapter

Accepts Fuses

SA-15

S-15 to S-7

SA-20

S-20

SA-30

S-25

SA 30

S-30 to S-20

SA Fustat Fuse Adapters

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

53

Solar

Products

Page

Fuse Holder & Block Selection Guide       54-55

Volt

Fuses

Size

600Vdc . . . . . . . . . 

PVM

. . . . .

13

32

˝ x 1 

1

2

˝ . . . . . . . . . . . 56

600Vac /300Vdc . . .

PVCF

. . . . .

CUBEFuse . . . . . . . . .57-58

600Vac/dc . . . . . . . 

PVS-R

. . . .

RK5 . . . . . . . . . . . . . . . . 59

1000Vdc . . . . . . . .

PV

. . . . . . .

10x38mm . . . . . . . . . . . 60

1000/1100Vdc . . . .

PV

. . . . . . .

14x51mm . . . . . . . . . . .61

1000Vdc . . . . . . . . 

NH1

. . . . . .

NH Size 1 . . . . . . . . . . . 62

1000Vdc . . . . . . . . 

XL PV

. . . . 

XL Size 01, 1, 2, 3 . . .63-65

1300/1500Vdc . . . .

PV

. . . . . . .

14x65mm . . . . . . . . . . . 66

1200/1500Vdc . . . .

XL PV

. . . . 

XL Size 01, 1, 2, 3 . . .67-69

Solar Fuse Products

RED 

indicates

NEW 

information

Scan this tag to get the latest product

information for Solar Products.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

54

Solar Fuse Products

Holders & Blocks For Branch Circuit Rated Fuses

600 Volts

Fuses

Volts

Page

Midget

PVM

600V

56

CF

CFPV

600V

57

RK5

PVS-R

600V

59

Holders

• TCFH Series CUBEFuse holder

32

• CHM Series DIN-Rail mount holders

274

• HEB Series in-line holders

310

Blocks

• Modular Knifeblade Fuse Blocks 250/600V, panel mount . . 289

• R600 Series RK5 open fuse blocks

296

• BM Series midget open fuse blocks

305

BM Series

HEB Series

TCFH Series

R600 Series

Modular

Knifeblade

1000 Volts

Fuses

Volts

Page

10x38mm

PV-_A10

1000V

60

14x51mm

PV-_A14

1000/1100V

61

NH1

PV-_ANH

1000V

62

01XL

PV-_A-01XL

1000V

63

1XL

PV-_A-1XL

1000V

63

2XL

PV-_A-2XL

1000V

63

3L

PV-_A-3L

1000V

63

Holders

• CHPV Series 10x38 DIN-Rail mount holders

274-277

• CH14 Series 14x51 DIN-Rail mount holders

274-277

• HEB Series* 10x38 in-line holders

310

• SD1 Series** NH1 holders

63

* Self certified to 1000Vdc.

** IEC only to 1000Vdc.

Blocks

• SD1XL-S Series 01XL & 1XL blocks

63

• SD2XL-S Series 2XL blocks

63

• SD3L-S Series 3L blocks

63

CHPV Series

CHM Series

CH14 Series

HEB Series

SD1-D-PV Series

SD1XL-S Series

SD2XL-S Series

SD3L-S Series

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

55

Solar

Products

Holders & Blocks For Branch Circuit Rated Fuses

Solar Fuse Products

SD1XL-S Series

SD2XL-S Series

SD3L-S Series

1500 Volts

Fuses

Volts

Page

01XL

PV-_A-01XL-15

1500V

63

1XL

PV-_A-1XL-15

1500V

63

2XL

PV-_A-2XL-15

1500V

63

3L

PV-_A-3L-15

1500V

63

14x65mm

PV-_A14*

1300/1500V

66

Blocks

• SD1XL-S Series** 01XL & 1XL blocks

63

• SD2XL-S Series** 2XL blocks

63

• SD3L-S Series** 3L blocks

63

* Available with tags for bolt mounting or 10mm fixings for mounting in modular blocks

for 10mm diameter fuses.

** IEC only to 1500Vdc.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

56

Solar Fuse Products

56

13

32

˝ x 1 

1

2

˝ Midget PV Fuses

Recommended Fuse Holders & Blocks For the PVM Fuse

• See page 54

Specifications
Description:

A range of UL 2579 

fast-acting 600Vdc Midget fuses specifically
designed to protect solor power systems in
extreme ambient temperature, high cycling
and low level fault current conditions
(reverse current, multi-array fault).

Dimensions:

13

32

˝ x 1 

1

2

˝ 

(10.3 x 38.1mm).

Ratings:

Volts — 600Vdc to UL 2579

Amps — 4-30A

IR — 50kA DC (4-30A)

Agency Information:

UL Listed 2579, Guide JFGA, File

E335324, CSA Component Certified C22.2.

Features and Benefits

• Specifically designed to protect solar power systems in

extreme ambient temperature per UL 2579 listed

• Capable of withstanding high cycling and low level fault 

current conditions

Typical Applications

• Solar Combiner Boxes
• Solar String Protectors

Catalog Numbers (Amps)

PVM-4

PVM-7

PVM-10

PVM-20

PVM-5

PVM-8

PVM-12

PVM-25

PVM-6

PVM-9

PVM-15

PVM-30

PVM

Data Sheet: 2153

Catalog             Amp              Power Loss (Watts)

Number

Rating

0.8 x I

n

1.0 x I

n

PVM-10

10

1.04

1.86

PVM-15

15

1.00

1.72

PVM-30

30

1.65

2.91

I

n

= Rated current

Power Loss (Watts)

Dimensions - (mm)

1.5"

±0.031
(38.1mm)

0.407"

±0.005
(10.3mm)

1

10

100

CURRENT IN AMPS

.01

.1

1

10

100

AMP
RATING

15 A

10 A

20 A

30 A

8 A

5 A

1,000

TIME IN SECONDS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

57

Solar

Products

57

Fast-Acting CUBEFuse™ 

Solar Fuse Products

PVCF Class CF Fuse

Data Sheet: 2155     

Fuse Catalog Numbers Non-Indicating (Amps)

PVCF35RN

PVCF50RN

PVCF80RN

PVCF40RN

PVCF60RN

PVCF90RN

PVCF45RN

PVCF70RN

PVCF100RN

Carton Quantity and Weight

Amp

Carton

Weight Per Carton

Rating

Qty.

lbs

kg

PVCF-35-60A

12

1.42

0.65

PVCF-70-100A

6

1.74

0.79

Catalog Symbol:

PVCF_RN

Fast-Acting Fuse:

6 minutes maximum clearing time at 200%

rated current for 30 to 60A fuse
8 minutes maximum clearing time at 200%
rated current for 70 to 100A fuse

Ratings:

Volts — 600Vac (Photovoltaic applications)

— 300Vdc

Amps — 35-100A

IR — 300kA RMS Sym. (UL)

— 200kA RMS Sym. (CSA)

— 50kA DC (UL & CSA)

Agency Information:

• UL 2579 Listed Fuse: Guide JFGA, File E335324
• CSA Certified Fuse: Class C22.2

Other Ratings/Specifications:

Watts Loss at Rated Current:

PVCF35RN: 5.45W
PVCF60RN: 7.27W
PVCF100RN: 11.50W

Operating and Storage Temperature Range:

-40 to 90°C

Material Specifications:

• Case: Glass filled PES (Polyethersulfone)
• Terminals: Copper alloy
• Terminal plating: Electroless tin

Features and Product Benefits

• Maximize uptime and reliability using fuses designed and

listed to UL 2579: 

Low Voltage Fuses - Fuses for

Photovoltaic Systems

.

• Minimize chances of equipment failure and personnel injury

when using full range fuses having the industry’s fastest
response time to low-magnitude faults.

• Maximize return on investment with fuses proven to 

withstand harsh temperatures.

• Minimize design time, operating outage time and 

replacement cost with fuses qualified in excessively 
changing enviromental conditions.

• Simplify compatibility with readily available industry 

standard Class CF holders.

• Temperature Derating: Designed to maximize rated capacity

in elevated environmental temperatures.

• Overload Protection: Proven to clear faults faster than the

UL requirement.

• Power Loss: Minimal energy consumption leading to

increased efficiency.

Recommended Fuse Holders For Class CF Fuses

• See pages 32 and 33

Scan this tag to get the latest product

information for the

New PVCF CUBEFuse.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

58

Solar Fuse Products

58

Fast-Acting CUBEFuse™ 

PVCF_RN Dimensions – in (mm)

Data Sheet: 2155     

CUBEFuse Holders

Catalog Numbers

(amps)

Fits Fuse Holder

Non-Indicating

TCFH60N

TCFH100N

PVCF35RN

X

X

PVCF40RN

X

X

PVCF45RN

X

X

PVCF50RN

X

X

PVCF60RN

X

X

PVCF70RN

X

PVCF80RN

X

PVCF90RN

X

PVCF100RN

X

Time-Current Characteristic Curves–Average Melt

Current Limitation Curves

100A

 

60A

 

40A

 

50A

 

35A

 

0.01 

0.1 

10 

100 

1000 

10 

100

 

1,000

 

10,000

 

TIME IN SECONDS 

CURRENT IN AMPS 

60A 

100A 

40A 

50A 
35A 

100 

1,000 

10,000 

100,000 

100

 

1,000 

10,000

 

100,000

 

INSTANTANE

OUS 

PE

AK 

LE

T THRU CURRENT IN 

AMPS

 

PROSPECTIVE SHORT CIRCUIT CURRENT 

 SYMMETRICAL RMS AMPS  

300,000 

A

Fuse

Dimensions - in (mm)

Amps

A

B

C

D

E

F

G

35-40

2.13

1.00

1.13

0.36

0.04

0.63

0.38

(54.10)

(25.40)

(28.58)

(9.10)

(1.02)

(15.93)

(9.65)

45-50

2.13

1.00

1.13

0.44

0.04

0.63

0.38

(54.10)

(25.40)

(28.58)

(11.13)

(1.02)

(15.93)

(9.65)

60

2.13

1.00

1.13

0.44

0.04

0.63

0.38

(54.10)

(25.40)

(28.58)

(11.13)

(1.02)

(15.93)

(9.65)

70

3.01

1.00

1.26

0.49

0.06

0.58

0.38

(76.45)

(25.40)

(32.00)

(12.45)

(1.60)

(14.78)

(9.65)

80-90

3.01

1.00

1.26

0.49

0.06

0.58

0.38

(76.45)

(25.40)

(32.00)

(12.45)

(1.60)

(14.78)

(9.65)

100

3.01

1.00

1.26

0.57

0.06

0.58

0.38

(76.45)

(25.40)

(32.00)

(14.48)

(1.60)

(14.78)

(9.65)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

59

Solar

Products

59

Solar Fuse Products

Limitron™ Fast-acting Fuses

Data Sheet: 4203

Specifications
Description:

A range of UL 2579 fast-acting

600Vdc Class RK5 fuses specifically
designed to protect solar power systems in
extreme ambient temperature, high cycling
and low level fault current conditions (reverse
current, multi-array fault).

Dimensions:

See page 15 for Class RK5

dimensions.

Ratings:

Volts — 600Vac to UL 248-12

600Vdc to UL 2579

Amps — 20-400A

IR — 200kA RMS Sym. AC

20kA DC (20-60A)
10kA DC (70-400A)

Agency Information:

UL Std. 248-12, Class RK5, UL

Listed, Guide JFGA, File E335324. Photovoltaic to UL 2579,
CSA Component Certified C22.2.

Features and Benefits

• Current limitation for non-inductive circuits provides Class

RK5 current-limiting response to ground fault and 

short-circuit conditions.

• Designed for the protection and isolation of photovoltaic

systems.

Typical Applications

• Photovoltaic systems
• Inverters
• Solar DC Safety Switches
• Recombiner Boxes

Catalog Numbers (Amps)

PVS-R-20

PVS-R-70

PVS-R-175

PVS-R-25

PVS-R-80

PVS-R-200

PVS-R-30

PVS-R-90

PVS-R-225

PVS-R-35

PVS-R-100

PVS-R-250

PVS-R-40

PVS-R-110

PVS-R-300

PVS-R-50

PVS-R-125

PVS-R-350

PVS-R-60

PVS-R-150

PVS-R-400

30A

60A

100A 200A 400A

0.01 

0.1 

10 

100 

1000 

10 

100 

1,000

 

10,000 

100,000

 

Time in Seconds

 

Current in Amps

 

Time-Current Characteristic Curves—Average Melt

PVS-R (600Vac/dc) Class RK5

Recommended Fuse Holders & Blocks For Class RK5 Fuses

• See page 19

Designed

to meet the new

UL Photovoltaic Fuse

Standar

d

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

60

Solar Fuse Products

Specifications
Class:

gPV

Description:

A range of fuses specifically

designed for the protection and isolation of
photovoltaic strings.

Dimensions:

13

32

” x 1

1

2

” 

(10.3 x 38.1mm).

Ratings:

Volts — 1000Vdc

Amps — 1-20A

IR — 33kAdc

IR (Min) — 1.3 x In

Agency Information:

CCC pending, UL Listed E335324,

IEC 60269-6, UL 2579, CSA.

Features and Benefits

• Capable of interrupting low over currents associated with

faulted PV strings.

• High DC voltage rating.
• Variety of mounting options for flexibility.

Catalog Numbers (Amps)

PV

Dimensions - mm

Time-Current Characteristic Curves—Average Melt

Data Sheet: 720110

Part Number

Current

Rating 

(Amps)

Energy Integrals I

2

t (A

2

s)

Watts Loss

Pre-Arcing

Total at 1000V

0.8 I

n

I

n

PV-1A10F

1

0.15

0.4

0.8

1.5

PV-2A10F

2

1.2

3.4

0.6

1.0

PV-3A10F

3

4

11

0.8

1.3

PV-3-5A10F

3.5

6.6

18

0.9

1.4

PV-4A10F

4

9.5

26

1.0

1.5

PV-5A10F

5

19

50

1.0

1.6

PV-6A10F

6

30

90

1.1

1.8

PV-8A10F

8

3

32

1.2

2.1

PV-10A10F

10

7

70

1.2

2.3

PV-12A10F

12

12

120

1.5

2.7

PV-15A10F

15

22

220

1.7

2.9

PV-20A10F

20

34

350

2.1

3.6

10x38mm Photovoltaic Fuses

Recommended Fuse Holders & Blocks For Class RK5 Fuses

• See page 19

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

61

Solar

Products

Solar Fuse Products

Specifications
Description:

A range of 14x51mm

package fuse links specifically designed
for protecting and isolating photovoltaic
strings. These fuse links are capable of
interrupting low overcurrents associated
with faulted PV systems (reverse
current, multi-array fault).

Dimensions:

See dimension illustration.

Construction:

Melamine tube with 

silver fuse element.

Ratings:

Rated Volts — 1000Vdc (25 & 32A)

1100Vdc (15 & 20A)

Rated Breaking Capacity: 10kA

Amps — 15-32A

Agency Information:

UL Listed, Guide JFGA, File

E335324. Photovoltaic to UL 2579,IEC 60269-6 gPV, CSA.
CCC pending.

Features and Benefits

• Specifically designed to provide fast-acting protection under

low fault current conditions associated with PV systems

• High DC voltage rating
• Demonstrated performance in extreme temperature

cycling conditions

Typical Applications

• Photovoltaic systems

Catalog Numbers

14x51mm

14x51mm Photovoltaic Fuses

Time-Current Characteristic Curves—Average Melt

Dimensions - mm

Current

Energy Integrats I

2

t (A

2

s)

Watts Loss

Part

Rating

Rated

Pre-Arcing

Total at Rated

Number

(Amps)

Voltage

Voltage

0.8In

In

PV-15A14F

15

1100Vdc

14

265

2.1

4

PV-20A14F

20

27

568

2.7

5

PV-25A14F

25

1000Vdc

65

943

2.7

5.1

PV-32A14F

32

120

1740

3.3

6.2

Data Sheet: 720132

Available Current (Amps), DC-Time Constant 1-3ms

Recommended Fuse Holders & Blocks For Class RK5 Fuses

• See page 19

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

62

Solar Fuse Products

Specifications
Description:

A range of NH fuse

links specifically designed for 
protecting and isolating photovoltaic
array combiners and disconnects.
These fuse links are  capable of 
interrupting low overcurrents 
associated with faulted PV systems
(reverse current, multi-array fault).

Dimensions:

See dimension 

illustration.

Construction:

Melamine tube with

silver fuse element.

Ratings:

Rated Volts — 1000Vdc

Rated Breaking Capacity: 50kA

Amps — 32-160A

Agency Information:

UL Listed, Guide JFGA, File

E335324. Photovoltaic to UL 2579,IEC 60269-6 gPV, CSA.
CCC pending.

Features and Benefits

• Specifically designed to provide fast-acting protection under

low fault current conditions associated with PV systems

• High DC voltage rating
• Variety of mounting options for flexibility
• Demonstrated performance in extreme temperature

cycling conditions

Typical Applications

• Photovoltaic systems
• Inverters

Catalog Numbers

NH1 Photovoltaic Fuses

Current

Energy Integrats I

2

t (A

2

s)

Watts Loss

Part

Rating

Pre-Arcing

Total at

Number

(Amps)

1000V

0.8In

In

PV-32ANH1

32

80

720

4.3

8.5

PV-40ANH1

40

185

1670

4.6

9

PV-50ANH1

50

400

3600

5.4

10.5

PV-63ANH1

63

470

4300

6.1

12

PV-80ANH1

80

640

5760

7.9

15.5

PV-100ANH1

100

1300

11,700

8.4

16.5

PV-125ANH1

125

2600

23,400

8.9

17.5

PV-160ANH1

160

5200

46,800

12.2

24

Time-Current Characteristic Curves—Average Melt

Dimensions - mm

Size 1

Available Current (Amps), DC-Time Constant 1-3ms

Data Sheet: 720133

Recommended NH1 Fuse Holders - SD(size)-D

• See page 54

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

63

Solar

Products

Solar Fuse Products

Data Sheet: 720134

XL Photovoltaic Fuses

Specifications
Description:

A range of XL package fuses specifically

designed for protecting and isolating photovoltaic array 
combiners and disconnects. 
These fuse links are capable of interrupting low overcurrents
associated with faulted PV systems (reverse current, 
multi-array fault). 

Dimensions:

See dimension illustration.

Ratings:

Volts — 1000Vdc

Amps — 63 to 630A:

IR — 50kA @ 63 to 160A

— 33kA @ 200 to 315A

— 50kA @ 350 to 630A

Agency Information:

— IEC 60269-6

— RoHS compliant

— UL 2579

— CSA
— CCC (pending

Features and Benefits

• Specifically designed to provide fast-acting protection under

low fault current conditions associated with PV systems

• High DC voltage rating
• Variety of mounting options for flexbility
• Demonstrated performance in extreme temperature

cycling conditions

Typical Applications

• Photovoltaic systems
• Inverters

Recomended Fuse Holders

• SD1XL-S (suitable for 01 and 1XL)
• SD2XL-S (suitable for 2XL)
• SD3L-S (suitable for 3L)

1000Vdc XL Style Photovoltaic
Fuses

Part Number/Style

Body

Current

Energy Integrals I

2

t (A

2

s)

Watts Loss

Bladed

Bolted

Size

Rating (Amps)

Volts

Pre-Arcing

Total @ 1000V

0.8I

n

I

n

PV-63A-01XL

PV-63A-01XL-B

63

350

2520

12

24

PV-80A-01XL

PV-80A-01XL-B

80

660

4752

14

27

PV-100A-01XL

PV-100A-01XL-B

01

100

1000Vdc

1350

9720

15

30

PV-125A-01XL

PV-125A-01XL-B

125

1930

13,896

20

40

PV-160A-01XL

PV-160A-01XL-B

160

3900

28,080

25

44

PV-200A-1XL

PV-200A-1XL-B

1

200

1000Vdc

9400

27,260

31

60

PV-200A-2XL

PV-200A-2XL-B

200

4152

31,000

29

62

PV-250A-2XL

PV-250A-2XL-B

2

250

1000Vdc

7721

57,000

35

70

PV-315A-2XL

PV-315A-2XL-B

315

17,600

130,000

40

75

PV-350A-3L

PV-350A-3L-B

350

30,885

160,700

41

90

PV-400A-3L

PV-400A-3L-B

3

400

1000Vdc

44,000

230,000

63

100

PV-500A-3L

PV-500A-3L-B

500

48,300

251,200

71

138

PV-630A-3L

PV-630A-3L-B

630

100,000

520,000

92

180

See Data Sheet 720146 for information
on the SD__-S Fuse Holders.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

64

Solar Fuse Products

XL Photovoltaic Fuses for Solar Applications

1XL Blade Size

1XL Bolt Size

2XL Blade Size

2XL Bolt Size

Dimensions - mm (not to scale)

3L Blade Size

3L Bolt Size

01XL Blade Size

01XL Bolt Size

Data Sheet: 720134

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

65

Solar

Products

Solar Fuse Products

Data Sheet: 720134

XL Photovoltaic Fuses for Solar Applications

Time Current Curves for 01XL and 1XL

Available Current (Amps), DC-Time Constant 1-3ms

Time Current Curves for 2XL

Available Current (Amps), DC-Time Constant 1-3ms

Time Current Curves for 3L

Available Current (Amps), DC-Time Constant 1-3ms

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

66

Solar Fuse Products

Cylindrical with 10mm Fixings PV - (amp rating)
A14LF10F

14x65mm Photovoltaic Fuses

Data Sheet: 720139

Specifications
Description:

A range of 14x65mm

package fuse links specifically designed
for protecting and isolating photovoltaic
strings. These fuse links are capable of
interrupting low overcurrents associated
with faulted PV systems (reverse
current, multi-array fault).

Dimensions:

See dimension illustration.

Construction:

Melamine tube with 

silver fuse element.

Ratings:

Rated Volts — 1300Vdc (25 & 32A)

1500Vdc (15 & 20A)

Rated Breaking Capacity: 10kA

Amps — 15-32A

Agency Information:

UL Listed, Guide JFGA, File

E335324. Photovoltaic to UL 2579,IEC 60269-6 gPV, CSA.
CCC pending.

Features and Benefits

• Specifically designed to provide fast-acting protection under

low fault current conditions associated with PV systems

• High DC voltage rating
• Demonstrated performance in extreme temperature

cycling conditions

Typical Applications

• Photovoltaic systems

Catalog Numbers

Part Number

Current

Rated

Energy Integrats I

a

t (A

2

s)

Watts Loss

Cylindrical

Cylindrical

Cylindrical with

Rating

Voltage

Pre-Arching

Total at

0.8 In

In

with Tags

10mm Fixings

(Amps)

Rated Voltage

PV-15A14LF

PV-15A14L-T

PV-15A14LF10F

15

1500Vdc

14

160

3.2

5.8

PV-20A14LF

PV-20A14L-T

PV-20A14LF10F

20

34

400

3.6

6.5

PV-25A14LF

PV-25A14L-T

PV-25A14LF10F

25

1300Vdc

65

550

4.1

7.5

PV-32A14LF

PV-32A14L-T

PV-32A14LF10F

32

105

900

5.7

10.4

Dimensions - mm

Cylindrical PV - (amp rating) A14LF

Cylindrical with Tags PV - (amp rating) A14L-T

67.34

69.34

77.12
75.12

10.99

90.07
88.07

4.70

15.22
15.02

14.22
14.02

84.77

86.77

10.25

10.05

Time-Current Characteristic Curves—Average Melt

Available Current (Amps), DC-Time Constant 1-3ms

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

67

Solar

Products

Solar Fuse Products

Data Sheet: 720134

XL Photovoltaic Fuses

Specifications
Description:

A range of XL package fuses specifically

designed for protecting and isolating photovoltaic array 
combiners and disconnects. 
These fuse links are capable of interrupting low overcurrents
associated with faulted PV systems (reverse current, 
multi-array fault). 

Dimensions:

See dimension illustration.

Ratings:

Volts — 1200Vdc (160A)

— 1500Vdc (50-125A, 200-400A)

Amps — 63 to 400A:

IR — 33kA

Agency Information:

UL Listed, Guide JFGA, File

E335324. Photovoltaic to UL 2579, IEC 60269-6 gPV, CSA.
CCC pending.

Features and Benefits

• Specifically designed to provide fast-acting protection under

low fault current conditions associated with PV systems

• High DC voltage rating
• Variety of mounting options for flexbility
• Demonstrated performance in extreme temperature

cycling conditions

Typical Applications

• Photovoltaic systems
• Inverters

Recomended Fuse Holders

• SD1XL-S (suitable for 01 and 1XL)
• SD2XL-S (suitable for 2XL)
• SD3L-S (suitable for 3L)

1500Vdc XL Style Photovoltaic
Fuses

Part Number/Style

Body

Current

Energy Integrals I

2

t (A

2

s)

Watts Loss

Bladed

Bolted

Size

Rating (Amps)

Volts

Pre-Arcing

Total @ 1000V

0.8I

n

I

n

PV-50A-01XL-15

PV-50A-01XL-B-15

50

280

1450

6

26

PV-63A-01XL-15

PV-63A-01XL-B-15

63

420

2250

17

28

PV-80A-01XL-15

PV-80A-01XL-B-15

01

80

1500Vdc

950

5000

18

30

PV-100A-01XL-15

PV-100A-01XL-B-15

100

1250

6500

22

38

PV-125A-01XL-15

PV-125A-01XL-B-15

125

2200

11,500

27

48

PV-160A-01XL-12

PV-160A-01XL-B-12

160

1200Vdc

5000

19,500

24

48

PV-100A-1XL-15

PV-100A-1XL-B-15

100

1250

6000

24

43

PV-125A-1XL-15

PV-125A-1XL-B-15

1

125

1500Vdc

1950

9360

25

52

PV-160A-1XL-15

PV-160A-1XL-B-15

160

4200

20,160

30

58

PV-200A-1XL-15

PV-200A-1XL-B-15

200

9400

45,120

31

61

PV-125A-2XL-15

PV-125A-2XL-B-15

125

1500Vdc

2200

11,000

23

43

PV-160A-2XL-15

PV-160A-2XL-B-15

2

160

5000

25,000

26

50

PV-200A-2XL-15

PV-200A-2XL-B-15

200

9300

36,000

28

56

PV-250A-2XL-15

PV-250A-2XL-B-15

250

13,700

68,000

38

72

PV-250A-3L-15

PV-250A-3L-B-15

250

20,000

61,000

35

62

PV-315A-3L-15

PV-315A-3L-B-15

3

315

1500Vdc

38,000

116,000

40

72

PV-355A-3L-15

PV-355A-3L-B-15

355

44,000

136,000

46

84

PV-400A-3L-15

PV-400A-3L-B-15

400

58,000

177,000

50

91

See Data Sheet 720146 for information
on the SD__-S Fuse Holders.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

68

Solar Fuse Products

XL Photovoltaic Fuses

Dimensions - mm
Bladed - Size 01XL, 1XL, 2XL and 3L

Size

a

b

c

d

e

f

g

h

i

j

01XL

193.8

127.8

124.6

128.6

20

7.9

43

40.4

21.3

5.8

1XL

189.8

127.8

119.6

123.6

20

13.4

51

39.8

20

5.8

2XL

204.5

128.5

119.3

123.3

26

14.38

59.2

47.9

20

5.8

3L

204.9

127.5

118.3

122.3

32.3

18.7

73.5

60

22

6

Bladed - Size 01XL, 1XL, 2XL and 3L

Bladed - Size 01XL, 1XL, 2XL and 3L

Size

a

b

c

d

e

f

g

h

i

01XL

187.6

127.8

6

43

58.3

164.3

150.3

10.4

20

1XL

183.6

127.8

6

51

66.3

160.3

146.3

10.4

20

2XL

191.3

128.5

6

59.2

74.5

167.8

154.8

10.5

25

Size

a

b

c

d

e

f

g

h

3L

199.7

128.5

6

73.5

88.8

169.7

10.5

30

Data Sheet: 720134

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

69

Solar

Products

Solar Fuse Products

Data Sheet: 720134

XL Photovoltaic Fuses

Time Current Curves for 01XL - 1500Vdc

Available Current (Amps), DC-Time Constant 1-3ms

Time Current Curves for 1XL - 1500Vdc

Available Current (Amps), DC-Time Constant 1-3ms

Time Current Curves for 2XL - 1500Vdc

Available Current (Amps), DC-Time Constant 1-3ms

Time Current Curves for 3L - 1500Vdc

Available Current (Amps), DC-Time Constant 1-3ms

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

70

Find blown fuses fast and easy. 
Utilize LED technology to 
indicate a blown fuse.

easy

ID

 

fuses

and fuse holders

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

71

Lo
w V

oltage

Supplementar

y

Fuses

Low Voltage
Supplementary Fuses

Section Contents

Page

Fuse Holder & Block Selection Guide . . . . . 72-73

Cable limiters & welder limiters

K Series cable limiters . . . . . . . . . 600V . . . . . . . . . . 74
64000 & 68000 welder limiters . . . 600V . . . . . . . . . . 74

13

32

˝ x 1 

1

2

˝ Fast-acting supplementary fuses

BAF  . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . 75
KTK  . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 75
KLM  . . . . . . . . . . . . . . . . . . . . . . 600Vac/dc . . . . . . 75

13

32

˝ x 1 

1

2

˝ Time-delay supplementary fuses

FNM . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . 76
FNQ . . . . . . . . . . . . . . . . . . . . . . 500V . . . . . . . . . . 76

13

32

˝ x 1 

3

8

˝ Fast-acting supplementary fuses

BBS . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 77

Pin indication fuses and actuator

GBA . . . . . . . . . . . . . . . . . . . . . .  125V . . . . . . . . . . 78
GLD . . . . . . . . . . . . . . . . . . . . . . 125V . . . . . . . . . . 78
MIC . . . . . . . . . . . . . . 250V fast-acting . . . . . . . . . . . 78
MIN . . . . . . . . . . . . . . 250V fast-acting . . . . . . . . . . . 78
FNA . . . . . . . . . . . . . . 250V time-delay  . . . . . . . . . .  78
MIS . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 79
KAZ . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 79

Limiters

ANN . . . . . . . . . . . .  . . 125V fast-acting  . . . . . . . . . 79
ANL . . . . . . . . . . . . . . 80Vdc time-delay  . . . . . . . . .  79
4164 & 4164-FR . . . . . . . . . .fuse blocks  . . . . . . . . .  79

In-line size rejecting fuses and fuse holders

GLQ . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 80
GMQ . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 80

In-line non-rejecting fuses and fuse holders

GLR . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 81
GMF . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 81
GRF . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 81

Automotive blade-type fuses

ATC . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 82
ATC-_ID . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 82
ATM . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . .

82

ATM-_ID . . . . . . . . . . . . . . . . . . . .32Vdc . . . . . . . . . 82
ATM-LP . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 82
MAX . . . . . . . . . . . . . . . . . . . . . .  32Vdc . . . . . . . .

83

MAX-_ID . . . . . . . . . . . . . . . . . . . .32Vdc . . . . . . . . . 83

Automotive blade-type fuse holders

HHC, HHD, HHF, HHG, ATC-FHID for ATC fuses . . . .  82
HHL, HHM, ATC-FHID for ATM fuses . . . . . . . . . . . . . 83
HHX for MAX fuses . . . . . . . . . . . . . . . . . . . . . . . . . .  83

PCB fuseclips for ATC/ATM blade, 5mm, 

1

4

˝ & 

13

32

˝ 

diameter fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84

RED 

indicates

NEW 

information

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

72

Low Voltage Supplementary Fuses

13

32

˝ X 1 

1

2

˝ Fuses

Catalog Number

Volts

Page

BAF . . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . 75
KTK . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . 75
KLM . . . . . . . . . . . . . . . . . . . . . . . 600Vac/dc . . . . . . . . . . . . . . . 75
FNM  . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . 76
FNQ . . . . . . . . . . . . . . . . . . . . . . . 500V . . . . . . . . . . . . . . . . . . . 76

Holders

• OPM-NG-SC3 3-pole, panel/DIN-Rail mount . . . . . . . . . . . . . . .286
• OPM-1038R 3-pole, panel/DIN-Rail mount . . . . . . . . . . . . . . . .285
• OPM-1038RSW 3-pole w/ switch, panel/DIN-Rail mount  . . . . .284
• CH Series Global 1- to 3-pole, DIN-Rail mount . . . . . . . . . . . . . 276
• HPG Panel mount fuse holder  . . . . . . . . . . . . . . . . . . . . . . . . .322
• HPC-D Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . .323
• HPM Panel mount fuse holder   . . . . . . . . . . . . . . . . . . . . . . . .323
• HPS Series Panel mount fuse holder  . . . . . . . . . . . . . . . . . . . .322
• HPF Series Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . 322
• HEB Series 1-Pole in-line fuse holder . . . . . . . . . . . . . . . . . . . .315
• HEX & HEY Series 2-Pole in-line fuse holders . . . . . . . . . . . . . 315
• NDNF1-WH Fuse holding rail mount terminal block . . . . . . . . . 327

Blocks

• BM Series, panel/DIN-Rail with adapters . . . . . . . . . . . . . . . . . 310
• 3723, 3742 and 3743 multi-pole add-on fuse blocks . . . . . . . . 326

OPM-NG-SC3

CH Series

CH Series

J600 Series

JP Series

BH Series

4164 & 4164-FR

Safety J™

Series

Modular

Type

H250 Series

H600 Series

OPM-1038R & 

OPM-1038RSW

Holders & Blocks for Low Voltage Supplementary Fuses

Limiters

Catalog Number

Volts

Page

K Series . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . 74
68000 Series . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . 74
64000 Series . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . 74
ANN Fast acting limiter . . . . . . . . . 125Vac/80Vdc . . . . . . . . . . . .  79
ANL Time-delay limiter . . . . . . . . . 80Vdc . . . . . . . . . . . . . . . . . . 79

Holders

• CH Series Class J modular 1 to 3-pole, panel/DIN rail mount . .283
• Safety J™ Series modular holders, panel/DIN rail mount . . . . . 288

Blocks

• Modular Type Fuse Blocks 250/600V, panel mount . . . . . . . . . 311
• H250 Series 1- to 3-pole 250V, panel mount . . . . . . . . . . . . . .296
• H600 Series 1- to 3-pole 600V, panel mount . . . . . . . . . . . . . .299

Blocks

• Modular Knifeblade Fuse Blocks 250/600V, panel mount . . . .  291

• Modular Type Fuse Blocks 600V, panel mount . . . . . . . . . . . . 311
• J600 Series, panel mount . . . . . . . . . . . . . . . . . . . . . . . . . . .  302
• JP Series pyramid blocks, panel mount . . . . . . . . . . . . . . . . . 304
• BH Series modular-style open blocks, panel mount . . . . . . . . 311

Limiter

Blocks - ANN & ANL

• Blocks for 4164 & 4164-FR . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

HPG

HPC-D

HPM

HPS

HPF

HEB Series

HEX & HEY

Series

NDNF1-WH

BM Series

Modular Knifeblade

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visitwww.cooperbussmann.com/DatasheetsEle

73

Low Voltage Supplementary Fuses

Lo
w V

oltage

Supplementar

y

Fuses

Holders & Blocks for Low Voltage Supplementary Fuses

In-Line Rejecting and Non-Rejecting Fuses

Catalog Number

Volts

Page

GLQ rejecting fuse . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 80
GMQ rejecting fuse . . . . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 80
GLR non-rejecting fuse . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 81
GMF non-rejecting fuse . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 81
GRF non-rejecting fuse . . . . . . . . . . . . .  300V . . . . . . . . . . . . . . . 81

Holders

• GLQ & GMQ: HLQ Rejection holder . . . . . . . . . . . . . . . . . . . . . 80
• GLR, GMF & GRF: HLR & HLR-2A non-rejection holders . . . . . .81

13

32

˝ X 1 

3

8

˝ Fuses

Catalog Numbers

Volts

Page

BBS . . . . . . . . . . . . . . . . . . . . . . . . . . .  600V . . . . . . . . . . . . . . . 77

Holder

• HPS-L Panel mount holder . . . . . . . . . . . . . . . . . . . . . . . . . . . 322

Blocks

• BM Series, panel/DIN rail with adapters . . . . . . . . . . . . . . . . . .310
• 3723, 3742 and 3743 multi-pole add-on fuse blocks . . . . . . . .326

Automotive Blade-type Fuses

Catalog Numbers

Volts

Page

ATC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 82
ATM  . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 82
MAX . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 83

Holders

• ATC: HHC, HHD, HHF, HHG & ATC-FHID In-line holders . . . . . .  82
• ATM: HHL, HHM & ATM-FHID In-line holders . . . . . . . . . . . . .  83
• MAX: HHX In-line holders  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

Pin Indicating Fuses

1

4

˝ X 1

1

4

˝ Fuse Catalog Numbers

Volts

Page

GBA 

1

4

" X 1 

1

4

" . . . . . . . . . . . . . . . . . . . . .125V . . . . . . . . . . . . . . . 78

GLD 

1

4

" X 1 

1

4

" . . . . . . . . . . . . . . . . . . . . .125V . . . . . . . . . . . . . . . 78

MIC 

13

32

" X 1 

1

2

" . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . . . . . . 78

MIN 

13

32

" X 1 

1

2

" . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . . . . . . 78

FNA 

13

32

" X 1 

1

2

" . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . . . . . . 78

MIS 

13

32

" X 2" . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 79

KAZ 

13

32

" X 2" . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 79

Holders

1

4

" X 1 

1

4

": HLD Panel mount visual indication  . . . . . . . . . . . . .321

1

4

" X 1 

1

4

": HK Series Panel mount lamp indicating . . . . . . . . . .321

Blocks

1

4

" X 1 

1

4

": Series 8000 for visual indication . . . . . . . . . . . . . . .324

13

32

" X 1 

1

2

": 1-Pole signal block cat. # 3839 (not shown in catalog)*

13

32

" X 2": 1-Pole signal block cat. # 2778 (not shown in catalog)*

13

32

" X 2": 2-Pole signal block cat. # 2837 (not shown in catalog)*

13

32

" X 2": 3-Pole signal block cat. # 2838 (not shown in catalog)*

*Call our customer satisfaction team at 636-527-3877 for more

information.

HPS-L

BM Series

HLD

HK Series

Series 8000

HHC, HHD, HHF

& HHG

easy ID™

Illuminating Holders

HHX

HLQ

Fuse Holders

HLR Fuse Holder

HHL & HHM

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

74

Low Voltage Supplementary Fuses

K Series

Specifications
Description:

Cable limiters.

Ratings:

Volts — 600Vac

IR — 200kA RMS Sym. @

600Vac

Agency Information:

UL

Listing: KDM, KDR, KDP and
KFM, KCM, KCM-B and KCR.

Features and Benefits

• Sizes and ratings available to

meet many applications.

Typical Applications

•  Protecting low voltage distribution and service entrance

cables against short-circuit currents.

Catalog Numbers

Copper Cable Limiter — 600 Volts

Catalog

Cable

Catalog

Cable

Number

Size

Number

Size

Tubular Terminals

KCY

#4

KCF

4/0

KCZ

#3

KCH

250 MCM

KCA

#2

KCJ

1, 2

350 MCM

KCB

#1

KCM

1, 2, 3

, KCM-B

1

500 MCM

KCC

1/0

KCV

600 MCM

KCD

1, 2

2/0

KCR

1, 2

750 MCM

KCE

3/0

KCS

1000 MCM

Tubular Terminal and Offset Bolt-Type Terminal

KQV

#12

KDD

1

2/0

KQT

#10

KDE

3/0

KFZ

#8

KDF

4/0

KIG

#6

KDH

250 MCM

KDY

#4

KDJ

1, 2

350 MCM

KDA

#2

KDM

1

2

3

500 MCM

KDB

#1

KDU

600 MCM

KDC

1/0

KDR

1

,

2

750 MCM

Compression Connector Rod and Tubular Terminals

KEX

4/0

KQO

350 MCM

KFH-A

250 MCM

KDT

2

500 MCM

*Center Bolt-Type Terminal and Off-Set Bolt-Type Terminal

KPF

4/0

KDP

1

500 MCM

KFT

1

250 MCM

KFM

1

750 MCM

KEW

1

350 MCM

*Copper or aluminum cable; sizes of all other limiters pertain to copper only. KFM copper only.

1

UL Listed (File E90818).

2

Available with shrink tube “_V” suffix.

3

Available with molded rubber boots. Add “–B” to end of part number.

Accessories

Boots can be purchased separately.

For KCM BOOT-KCM

For KDM BOOT-KDM

Installation tools can be purchased separately from Thomas and Betts

• Crimp Tool: TBM-14M

• Die: 15506 KDM/15515 KDR

Specifications
Description:

Welder limiters.

Ratings:

Volts — 600Vac (or less)

IR — 200kA RMS Sym.

Features and Benefits

• Current-limiting devices designed specially for use

on welder circuits only

• Time-current characteristics are designed to hold

on the intermittent overloading encountered in
welder operation, while providing short-circuit 
protection to the circuit and equipment

• Welder limiters have excess current capacity in the

operating range as needed for this type of service

Typical Applications

• Welder circuits
• Because welder limiters have special characteristics, they

are not intended for application on general-use circuits

Catalog Numbers

Catalog

Fuse Holder

Nominal

Numbers

Type

Amp Rating

68300

Class H

300

68600

Class H

600

64200

Class J

200

64300

Class J

300

Cable Limiters & Welder Limiters

Data Sheet: 1042

Data Sheet: 1045

64000 & 68000 Series

Recommended Fuse Blocks For 68000 & 64000

Series limiters

• See page 72

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

75

Low Voltage Supplementary Fuses

Lo
w V

oltage

Supplementar

y

Fuses

Recommended fuse blocks/fuse holders for 

13

32

” x 1 

1

2

” fuses

• See page 72

Data Sheet: 1011

Data Sheet: 2011 (0-30)

Specifications
Class:

Supplemental

Description:

Fast-acting

supplementary fuse.

Dimensions:

13

32

˝ x 1 

1

2

˝

(10.3 x 38.1mm).

Ratings:

Volts — 250Vac (or less)

Amps — 

2

10

-30A

IR — 10kA @ 125Vac

(

2

10

-30A)

— 35A (

2

10

-1A @ 250Vac)

— 100A (1

1

2

-3A @ 250Vac)

— 200A (4-10A @ 250Vac)

— 750A (12A- 15A @ 250Vac)

— 200A (20-30A @ 250Vac)

Agency Information:

CE, Std. 248-14,

UL 0-15/250V, Guide JDYX, File E19180
CSA Certified, 0-15/250V, Class
1422-01, File 53787.

Features and Benefits

• Low cost supplemental protection of

125V and 250V non-inductive circuits.

• Upgrade with LP-CC product to reduce

SKU investment and minimize potential
arc-flash hazards. (and minimize
potential for misapplying fuse.)

Typical Applications

• General Purpose Circuits
• Lighting Circuit Protection
• Meter Circuits

Catalog Numbers (Amps)

BAF-

1

4

BAF-2-

1

2

BAF-9

BAF-

1

2

BAF-3

BAF-10

BAF-

6

10

BAF-4

BAF-12

BAF-

8

10

BAF-5

BAF-15

BAF-1

BAF-6

BAF-20

BAF-1-

1

2

BAF-6-

1

4

BAF-25

BAF-1-

8

10

BAF-7

BAF-30

BAF-2

BAF-8

*All have interrupting rating of 10,000A at 125V.

KTK

Specifications
Class:

Supplemental

Description:

Fast-

acting supplementary
fuse.

Dimensions:

13

32

˝ x 

1

2

˝ (10.3 x 38.1mm).

Ratings:

Volts — 600Vac (or

less)

Amps — 

1

10

-30A

IR — 100kA RMS Sym. (UL)

Agency Information:

CE, Std. 248-14,

UL Listed, Guide JDYX, File E19180. 

Features and Benefits

• Low cost supplemental protection of 600V

or less non-inductive circuits.

• Upgrade with LP-CC product to reduce

SKU investment and minimize potential
arc flash hazards.

Typical Applications

• Control Circuits
• Lighting Circuit Protection
• Meter Circuits

Catalog Numbers (Amps)

600Vac - UL Listed and CSA

KTK-

1

10

KTK-

3

4

KTK-4

KTK-12

KTK-50*

KTK-

1

8

KTK-1

KTK-5

KTK-15

KTK-

2

10

KTK-1-

1

4

KTK-6

KTK-20

KTK-

1

4

KTK-1-

1

2

KTK-7

KTK-25

KTK-

3

10

KTK-2

KTK-7-

1

2

KTK-30

KTK-

4

10

KTK-2-

1

2

KTK-8

KTK-35*

KTK-

1

2

KTK-3

KTK-9

KTK-40*

KTK-

6

10

KTK-3-

1

2

KTK-10

KTK-45*

*Rated for no more than 24A continuous.

13

32

˝ x 1 

1

2

˝ Fast-acting Fuses

BAF

KLM

Specifications
Class:

Supplemental

Description:

Full range, 

fast-acting, DC midget
fuse.

Dimensions:

13

32

˝ x 1 

1

2

˝ 

(10.3 X 38.1mm).

Ratings:

Volts — 600Vac/dc

Amps — 

1

10

-30A

IR — 100kA AC 

 — 50kA DC

Agency Information:

CE, UL 

Listed: STD. 248-14, 
(FILE #E19180), CSA Certified, 
C22.2 NO. 248. 14 (CLASS 
#1422-01, FILE #53787).

Features and Benefits

• Full range, fast-acting, 600Vac/dc

midget fuse.

• Minimum interrupting rating or 200%

rated current at 600Vdc.

Typical Applications

• DC Control Circuits Requiring 

Fast-Acting Fuses.

• Solar power energy sources - use the

Bussmann PVM fuse for DC ratings
up to 600Vdc.

Catalog Numbers (Amps) - KLM

KLM-

1

10

KLM-

3

4

KLM-5

KLM-20

KLM-

1

8

KLM-1

KLM-6

KLM-25

KLM-

2

10

KLM-1-

1

2

KLM-8

KLM-30

KLM-

1

4

KLM-2

KLM-10

KLM-

3

10

KLM-3

KLM-12

KLM-

1

2

KLM-4

KLM-15

Data Sheet: 2020

For superior electrical protection, Bussmann 
recommends upgrading BAF and fuse applications to
Low-Peak LP-CC fuses See page 23.

For superior electrical protection, Bussmann 
recommends upgrading KTK fuse applications to
Low-Peak LP-CC fuses See page 23.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

76

Low Voltage Supplementary Fuses

Specifications
Class:

Supplemental

Description:

Time-delay 

supplementary fuse.

Dimensions:

13

32

˝ x 1

1

2

˝ 

(10.3 x 38.1mm).

Ratings:

Volts — 250Vac (or less)

Amps — 

1

10

-30A

IR — 35A (

1

10

-1A @ 250Vac)

— 100A (1

1

8

-3

1

2

A @ 250Vac)

— 200A (4-10A @ 250Vac)

— 10kA (

1

10

-10A @ 125Vac)

— 10kA (12-30A @ 250Vac)

Agency Information:

CE, Std. 248-14, UL Listed, 

0-30/250Vac; File E19180, Guide JDYX, CSA Certified, 
1-30/250Vac; Class 1422-01, File 53787.

Features and Benefits

• Low cost supplemental protection of 125V and 250V

inductive circuits.

Typical Applications

• General Purpose Circuits
• Lighting Circuit Protection
• Meter Circuits
• Upgrading to LP-CC product will reduce SKU investment

and minimize potential for misapplying fuse

Catalog Numbers (Amps)

FNM-

1

10

FNM-

1

2

FNM-1-

1

2

FNM-3

FNM-6

FNM-15

FNM-

1

8

FNM-

6

10

FNM-1-

6

10

FNM-3-

2

10

FNM-6-

1

4

FNM-20

FNM-

15

100

FNM-

3

4

FNM-1-

8

10

FNM-3-

1

2

FNM-7

FNM-25

FNM-

2

10

FNM-1

FNM-2

FNM-4

FNM-8

FNM-30

FNM-

1

4

FNM-1-

1

8

FNM-2-

1

4

FNM-4-

1

2

FNM-9

FNM-

3

10

FNM-1-

1

4

FNM-2-

1

2

FNM-5

FNM-10

FNM-

4

10

FNM-1-

4

10

FNM-2-

8

10

FNM-5-

6

10

FNM-12

Specifications
Class:

Supplemental

Description:

Time-delay supplementary

fuse.

Dimensions:

13

32

˝ x 1

1

2

˝ (10.3 x 38.1mm).

Ratings:

Volts — 500Vac (or less)

Amps — 

1

10

-30A

IR — 10kA RMS Sym.

Agency Information:

CE, Std. 248-14, UL Listed, Guide

JDYX, File E19180 CSA Certified, Class 1422-01, File
53787.

Features and Benefits

• Low cost supplemental protection of transformers and

relays at 500V or less.

Typical Applications

• Control Transformer 480V Primary Protection
• Lighting Circuit Protection
• Meter Circuits

Catalog Numbers (Amps)

FNQ-

1

10

FNQ-

4

10

FNQ-1-

1

2

FNQ-3-

1

2

FNQ-7

FNQ-20

FNQ-

1

8

FNQ-

1

2

FNQ-1-

6

10

FNQ-4

FNQ-8

FNQ-25

FNQ-

15

100

FNQ-

6

10

FNQ-2

FNQ-4-

1

2

FNQ-9

FNQ-30

FNQ-

3

16

FNQ-

8

10

FNQ-2-

1

4

FNQ-5

FNQ-10

FNQ-

2

10

FNQ-1

FNQ-2-

1

2

FNQ-5-

6

10

FNQ-12

FNQ-

1

4

FNQ-1-

1

8

FNQ-3

FNQ-6

FNQ-14

FNQ-

3

10

FNQ-1-

1

4

FNQ-3-

2

10

FNQ-6-

1

4

FNQ-15

13

32

˝ x 1 

1

2

˝ Time-delay Fuses

Data Sheet: 2028

Data Sheet: 1012

For superior electrical protection, Bussmann recommends upgrading FNM and
FNQ fuse applications to Low-Peak LP-CC fuses See page 23.

Recommended fuse blocks and fuse holders for 

13

32

˝ x 1 

1

2

˝ fuses

• See page 72

For superior electrical protection, Bussmann recommends upgrading FNM and
FNQ fuse applications to Low-Peak LP-CC fuses See page 23.

Recommended fuse blocks and fuse holders for 

13

32

˝ x 1 

1

2

˝ fuses

• See page 72

FNM

FNQ

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

77

Low Voltage Supplementary Fuses

Lo
w V

oltage

Supplementar

y

Fuses

Specifications
Class:

Supplemental

Description:

Fast-acting 

supplementary fuse.

Dimensions:

13

32

˝ x 1

3

8

˝ 

(10.3 x 34.9mm).

Construction:

Fiber cartridge.

Ratings:

Volts — 600Vac (

1

10

-5A)

— 250Vac (6 - 10A)

— 48Vac (12-30A)

Amps — 

1

10

-30A

IR — 10kA RMS Sym.

Agency Information:

CE, Std. 248-14, UL Listed, 

0-5A/600V, Guide JDYX, File E19180, CSA Certified, 
0-5A/600V, Class 1422-01, File 53787.

Features and Benefits

• Low cost supplemental protection of non-inductive circuits
• Reduced interchangeability with other supplemental fuses

minimizes misapplication

Typical Applications

• Control Circuits
• Lighting Ballasts
• Meter Circuits

Catalog Numbers (Amps)

BBS-

1

10

BBS-

8

10

BBS-4

BBS-15

BBS-

2

10

BBS-1

BBS-5

BBS-20

BBS-

1

4

BBS-1-

1

2

BBS-6

BBS-25

BBS-

4

10

BBS-1-

6

10

BBS-7

BBS-30

BBS-

1

2

BBS-1-

8

10

BBS-8

BBS-

6

10

BBS-2

BBS-10

BBS-

3

4

BBS-3

BBS-12

13

32

˝ x 1 

3

8

˝ Fast-acting Fuses

Data Sheet: 2010 (0-30A)

Recommended fuse blocks/fuse holders for 

13

32

˝ x 1 

3

8

˝ fuses

• Page 73

BBS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

78

Low Voltage Supplementary Fuses

Specifications
Class: 

Supplemental

Description:

Time-delay,

pin indication fuse.

Dimensions:

13

32

˝ x 1 

1

2

˝

(10.3 x 38.1mm).

Ratings:

Volts — 250Vac (

1

10

-

8

10

A)

— 125Vac (1-15A)

— 32Vac (20-30A)

Amps — 

1

10

-30A

IR — 35A (

1

10

-

8

10

A @ 250Vac)

— 10kA (

1

10

-15A @ 125Vac)

— 1kA (20-30A @ 32V)

Agency Information:

CE, Std. 248-

14, UL Listed 

1

10

-

8

10

A, IR 35A@ 250V,

IR 10kA@ 125V , 1-15A, IR 10kA@
125V, Guide JDYX, File 19180, CSA
Certified, 0-

8

10

A/250V, 1-10A/125V,

Class 1422-01, File 53787.

Features and Benefits

• FNA has a pin indicator providing

visual identification of failed circuits,
resulting in reduced circuit downtime.

• Time-delay response allows close

sizing on control transformers and
relays

Typical Applications

• Control Circuits
• Electronic Circuits

Catalog Numbers (Amps)

FNA-

1

10

FNA-

8

10

FNA-2-

1

2

FNA-6-

1

4

FNA-

1

8

FNA-1

FNA-2-

8

10

FNA-7

FNA-

15

100

FNA-1-

1

8

FNA-3

FNA-8

FNA-

2

10

FNA-1-

1

4

FNA-3-

2

10

FNA-9

FNA-

1

4

FNA-1-

4

10

FNA-3-

1

2

FNA-10

FNA-

3

10

FNA-1-

1

2

FNA-4

FNA-12*

FNA-

4

10

FNA-1-

6

10

FNA-4-

1

2

FNA-15*

FNA-

1

2

FNA-1-

8

10

FNA-5

FNA-20*

FNA-

6

10

FNA-2

FNA-5-

6

10

FNA-25*

FNA-

3

4

FNA-2-

1

4

FNA-6

FNA-30

*12-30A versions are dual-tube construction

MIC & MIN

Specifications
Class:

Supplemental

Description:

Fast-

acting, pin indication
fuse.

Dimensions:

13

32

˝ x 1 

1

2

˝ (10.3 x

38.1mm) 5AG.

Ratings:

Volts — 250Vac 

(1-15A)

— 32Vac (20-30A)

Amps — 1-30A

IR — 35A (1A @250Vac)

— 100A (2-3A @250Vac)

— 200A (5-10A @250Vac)

— 750A (15A @250Vac)

— 10kA (20-30A @32V)

— 35A (1A @250Vac)

Agency Information:

CE, Std. 248-14,

MIC—0-15A UL Listed, 125Vac/10kA IR
Guide JDYX, File E19180, MIN—1-5A
CSA Certified, Class 1422-01, File
53787.

Features and Benefits

Type MIN has a “red” pin indicator
providing visual identification of failed 
circuits, resulting in faster trouble
shooting (reduced circuit downtime).

Type MIC has silver-plated pin 
transmitting an electrical signal indicating
location of a failed circuit, resulting in
faster troubleshooting (reduced circuit
downtime).

Typical Applications

Control Circuits

PLC Circuits

Electronic Circuits

MIC Catalog Numbers (Amps)

MIC-1

MIC-5

MIC-20

MIC-2

MIC-10

MIC-25

MIC-3

MIC-15

MIC-30

MIN Catalog Numbers (Amps)

MIN-1

MIN-5

MIN-20

MIN-2

MIN-10

MIN-25

MIN-3

MIN-15

MIN-30

Specifications
Class: 

Supplemental

Description:

Fast-acting, pin

indication fuse.

Dimensions:

1

4

˝ x 1 

1

4

˝ 

(6.6 x 31.7mm) 3AG.

Ratings:

Volts — See Agency Info

below

Amps — 

1

2

-15A

IR — See Agency Info below

Agency Information:

CE, Std. 248-

14, UL Listed, 0-5A/125Vac, 10,000
AIC, Guide JDYX, File E19180, UL
Recognized, 6A/125Vac, 1000AIC 
8-15A/50Vac/dc, 300 AIC Guide
JDYX2, File E19180, CSA Certified: 
0-5A/125Vac, 10,000 AIC Class 
1422-01, File 53787.

Features and Benefits

• Type GBA has a “red” pin indicator

providing visual identification of failed
circuits, resulting in faster 
troubleshooting (reduced circuit
downtime).

• Type GLD has a plated pin to 

activate transmitting a electrical 
signal to indicate the location of
opened circuits, resulting in reduced
downtime.

Typical Applications

• Control Circuits
• Electronic Circuits

GLD Catalog Numbers (Amps)

GLD-

1

2

GLD-2

GLD-6

GLD-

3

4

GLD-3

GLD-10

GLD-1

GLD-4

GLD-12

GLD-1-

1

2

GLD-5

GLD-15

GBA Catalog Numbers (Amps)

GBA-

1

2

GBA-2

GBA-8

GBA-

3

4

GBA-3

GBA-10

GBA-1

GBA-4

GBA-15

GBA-1-

1

2

GBA-5

Pin Indication Fuses

Data Sheet: 2029

Data Sheet: 2012

Data Sheet: 2047

GBA

GLD

FNA

Recommended fuse blocks/fuse

holders for 

1

4

˝ x 1 

1

4

˝ indicating fuses

• Page 73

Recommended signal block for

13

32

˝ x 1 

1

2

˝ indicating fuses

• Page 73

Recommended signal block for

13

32

˝ x 1 

1

2

˝ indicating fuses

• Page 73

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

79

Low Voltage Supplementary Fuses

Lo
w V

oltage

Supplementar

y

Fuses

Data Sheet: 2133

ANN & ANL Limiters

Specifications
Description:

Circuit limiters.

ANN: 

Very fast-acting limiter.

ANL:

Non-time delay limiter.

Dimensions:

7

8

˝ x 3 

3

16

˝ 

(22.2 x 81.0mm).

Ratings:

ANN:

Volts — 125Vac

— 80Vdc

Amps — 10-800A

IR — 2500A @ 125Vac

— 2700A @ 80Vdc

ANL:

Volts — 80Vdc

Amps — 35-750A

IR — 2700A @ 80Vdc

Agency Information:

ANN:

35-400A @ 125Vac, IR=2500A

and 500A @ 80Vdc, IR=2700A: UL
Recognized Guide JFHR2, File
E56412; CSA Certified Class 1422-30,
File 53787, CE for 35-400A.

ANL:

UL Recognized, CSA Certified,

35-750A @ 80Vdc, IR = 2700A, Guide
JFHR2, File E56412, Class 1422-30,
File 53787, SAE J1171.

Features and Benefits

• Fast-acting circuit protection (ANN).
• Time-delay sizing for inductive circuits (ANL).
• Window shows limiter status.

Typical Applications

• Fork lifts, Marine, Aviation

ANN Catalog Numbers (Amps)

ANN-10

ANN-90

ANN-225

ANN-400

ANN-35

ANN-100

ANN-250

ANN-500

ANN-40

ANN-125

ANN-275

ANN-600

ANN-50

ANN-150

ANN-300

ANN-700

ANN-60

ANN-175

ANN-325

ANN-800

ANN-80

ANN-200

ANN-350

ANL Catalog Numbers (Amps)

ANL-35

ANL-125

ANL-250

ANL-500

ANL-40

ANL-130

ANL-275

ANL-600

ANL-50

ANL-150

ANL-300

ANL-675

ANL-60

ANL-175

ANL-325

ANL-750

ANL-80

ANL-200

ANL-350

ANL-100

ANL-225

ANL-400

4164 & 4164-FR Limiter Blocks

Specifications
Description:

Limiter fuse blocks for ANL 

& ANN.

• 4164 furnished with nylon inserted locknuts
• 4164-FR furnished with standard hex nuts

Dimensions:

Length: 3.38˝ 

Width: 0.95˝
Height: 1.62˝

Studs center to center: 2.43˝

Ratings:

Volts — 125Vac

— 80Vdc

— 32Vdc (Self Certified)

Amps — 10-800A

Poles: 

1 - stud terminal

KAZ

Specifications
Description:

Non-fuse 

actuator.

Dimensions:

13

32

˝ x 2˝ 

(10.3 x 50.8mm).

Ratings:

Volts — 600Vac

Amps — N/A

IR — 200kA

Agency Information:

CE, UL Listed, Guide
JDVS, File E58836.

Features and Benefits

• Bussmann signal blocks

2778, 2837 
or 2838 with KAZ actua-
tors mounted in parallel with fuses hav-
ing a rating of 50A or larger to provide
blown fuse dropout of shunt-trip fused
switches.

• Type KAZ can be used in circuits rated

600V or less.

• Type KAZ has an interrupting rating of

200kA.

Typical Applications

• Large, Shunt-Trip Fused Switches
• Fuse Protected Circuits Rated 50A or

Larger With Shunt-Trip Devices.

Catalog Number: KAZ

MIS

Specifications
Class: 

Supplemental

Description:

Non time-

delay pin indication fuse.

Dimensions:

13

32

˝ x 2˝

(10.3 x 50.8mm).

Ratings:

Volts — 600Vac

Amps — 1-12A

IR — 200kA

Features and Benefits

• Type MIS has a pin 

indicator providing visual
identification of failed cir-
cuits, 
resulting in faster trou-
bleshooting (reduced circuit down-
time).

• Type MIS can be used in circuits

rated 600V or less.

• Type MIS has an interrupting

rating of 200kA.

Typical Applications

• 480V Control Circuits
• PLC Circuits

Catalog Numbers (Amps)

MIS-1

MIS-4

MIS-10

MIS-2

MIS-5

MIS-12

MIS-3

MIS-8

Test Specifications

Fuse

Load

Opening Time

All

110%

0  4 hrs. (min.)

1-5A

150%

0  6 min. (max.)

6-12A

150%

12 min. (max.)

Pin Indication Fuse and Actuator, and Limiters

Data Sheet: 2021

Data Sheets: 2023 (ANN), 2024 (ANL)

Recommended signal block for

13

32

˝ x 2˝ indicating fuses

• Page 73

Recommended signal block for 

13

32

˝ x 2˝ indicating fuses

• Page 73

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

80

Low Voltage Supplementary Fuses

In-line Size Rejecting Fuses and Fuse Holders

Data Sheet: 2030

Data Sheet: 2033

HLQ

3

Fuse Holders

for both GLQ & GMQ fuses.

GLQ

Specifications
Class: 

Supplemental

Description:

Fast-acting,

size-rejecting in-line fuse.

Construction:

Glass tube.

Ratings:

Volts — 300Vac (or less)

Amps — 1-10A

IR — 10kA

Agency Information:

CE, Std. 248-14, UL Listed (Guide

JDYX, File E19180), CSA Certified, (Class 1422-01,
File 53787).

Features and Benefits

• In-Line, fast-acting circuit protection.
• Rejection feature prevents overfusing.

Typical Applications

• In-line Lighting Ballast Protection

Catalog Numbers (Amps) and Rejection Holders

Fuse

Holder

1, 2

Fuse

Holder

1, 2

GLQ-1

HLQ-1-

6

10

GLQ-3

HLQ-3 -

2

10

GLQ-1-

1

2

HLQ-1-

6

10

GLQ-4

HLQ-5

GLQ-1-

6

10

HLQ-1-

6

10

GLQ-5

HLQ-5

GLQ-2

HLQ-3 -

2

10

GLQ-9

HLQ-10

GLQ-2 -

1

2

HLQ-3 -

2

10

GLQ-10

HLQ-10

1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235

10A, 300Vac.

2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a

keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909
for thickness 0.030” to 0.042”.

Do not put tension on line (rear) terminal of fuse holder.

GMQ

Specifications

Class: 

Supplemental

Description:

Time-delay,

size-rejecting in-line fuse.

Construction:

Ceramic tube.

Ratings:

Volts — 300Vac (or less)

Amps — 

1

2

-6

1

4

A

IR — 10kA

Agency Information:

CE, Std. 248-14, UL Listed (Guide

JDYX, File E19180), CSA Certified, (Class 1422-01, File
53787)

Features and Benefits

• In-line, fast-acting circuit protection.
• Rejection feature prevents overfusing.

Typical Applications

• In-Line Lighting Ballast Protection

Catalog Numbers (Amps) and Rejection Holders

Fuse

Holders

1, 2

Fuse

Holders

3, 4

GMQ-

1

2

HLQ-

1

2

GMQ-2-

1

2

HLQ-3 -

2

10

GMQ-

6

10

HLQ-1-

6

10

GMQ-3

HLQ-3 -

2

10

GMQ-

8

10

HLQ-1-

6

10

GMQ-3 -

2

10

HLQ-3 -

2

10

GMQ-1

HLQ-1-

6

10

GMQ-4

HLQ-5

GMQ-1-

1

4

HLQ-1-

6

10

GMQ-6

HLQ-8

GMQ-1-

6

10

HLQ-1-

6

10

GMQ-6 -

1

4

GMQ-2

HLQ-3 -

2

10

1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235

10A, 300Vac.

2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a

keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909
for thickness 0.030” to 0.042”

Do not put tension on line (rear) terminal of fuse holder.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

81

Low Voltage Supplementary Fuses

Lo
w V

oltage

Supplementar

y

Fuses

GLR

Specifications
Class: 

Supplemental

Description:

Fast-acting,

non-rejection, in-line fuse.

Construction:

Glass tube.

Ratings:

Volts — 300Vac (or less)

Amps — 

3

16

-15A

IR — 10kA

Agency Information:

CE, Std. 248-14, UL Listed, 

0-15A/300Vac (Guide JDYX, File E19180), CSA Certified,
0-10A/300V (Class 1422-01, File 53787).

Features and Benefits

• In-line, fast-acting circuit protection.

Typical Applications

• In-Line Lighting Ballast Protection

Catalog Numbers (Amps) and Non-Rejection Holders

Fuse

Holder

1, 2*

Fuse

Holder

1, 2*

GLR-

1

2

HLR

GLR-6

HLR

GLR-1

HLR

GLR-7

HLR

GLR-1-

1

2

HLR

GLR-8

HLR

GLR-1 -

6

10

HLR

GLR-9

HLR

GLR-2

HLR

GLR-10

HLR

GLR-3

HLR

GLR-12

HLR

GLR-4

HLR

GLR-15

HLR-2A

GLR-5

HLR

1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01,

File 47235 12A, 300Vac.

2) Units can be panel-mounted either in a knockout hole with a separate steel clip 

(BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of
thickness 0.043”to 0.062” or #4909 for thickness 0.030˝ to 0.042˝.

*  For two leads (one each for line and loadside) order HLR-2A,

15A, 300V

An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes

WITHOUT

leads. The customer inserts #18 insulated solid copper wire into the line side

receptacle as well as into the load side receptacle. It has the same body dimensions,
utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A
fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA
Certified, 10A, 300Vac, Class 6225-01, File 47235.

Do not put tension on line (rear) terminal of fuse holder.

GMF

GRF

Specifications
Class: 

Supplemental

Description:

Time-delay, 

non-rejection, in-line fuse.

Construction:

Glass tube.

Ratings:

Volts — 300Vac (or less)

Amps — 

3

10

-10A

IR — 10kA

Agency Information:

CE, Std. 248-14 0-10A, UL Listed

(Guide JDYX, File E19180), CSA Certified, (Class 1422-01,
File 53787).

Features and Benefits

• In-line, time-delay circuits protection.

Typical Applications

• In-Line Lighting Ballast Protection

Catalog Numbers (-Amps) and Non-Rejection Holders

Fuse

Holder

1, 2*

Fuse

Holder

1, 2*

GMF-

3

10

HLR

GMF-3

HLR

GMF-

1

2

HLR

GMF-3 -

2

10

HLR

GMF-

6

10

HLR

GMF-4

HLR

GMF-

8

10

HLR

GMF-5

HLR

GMF-1

HLR

GMF-6 -

1

4

HLR

GMF-1-

1

4

HLR

GMF-10

HLR

GMF-1-

6

10

HLR

GRF-7

HLR

GMF-2

HLR

GRF-8

HLR

GMF-2 -

1

2

HLR

GRF-10

HLR

GMF-2 -

8

10

HLR

1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235

12A, 300Vac.

2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a

keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909
for thickness 0.030˝ to 0.042˝.

*For two leads order HLR-2A, 15A, 300V

An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes 

WITHOUT

leads.

The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the
load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes
the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide
IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235.

Do not put tension on line (rear) terminal of fuse holder.

In-line Non-rejecting Fuses and Fuse Holders

Data Sheet: 2032

Data Sheet: 2031

HLR 

Fuse Holder

HLR-2A 

Fuse Holder

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

82

Low Voltage Supplementary Fuses

Specifications
Description:

Fast-acting 

blade fuse.

Construction:

Colored plastic

housing with zinc fuse element.

Ratings:

Volts — 32Vdc

Amps — 1-40A

IR — 1000A

Agency Information:

UL

Recognized, (3-40A) (Guide
JFHR2, File E56412), SAE
Standard J1284.

Features and Benefits

• Color coded plastic housing for

easy identification of fuse ratings

Typical Applications

• Automotive

Catalog Numbers (Amps)

Automotive Blade-type Fuses & Holders

Data Sheet: 2048

Data Sheet: 2009

(Actual Size)

ATC Fuse

ATM Fuse

Specifications
Description:

Fast-acting blade fuse.

Construction:

Colored plastic housing

with zinc fuse element.

Ratings:

Volts — 32Vdc

Amps — 2-30A

IR — 1000A

Features and Benefits

• Color coded plastic housing for easy

identification of fuse ratings

Typical Applications

• Automotive

Catalog Numbers (Amps)

ATM

(Actual Size)

ATM-LP

Non-Indicating

*Indicating

Color

ATC-1

Black

ATC-2

Gray

ATC-3

ATC-3ID

Violet

ATC-4

Pink

ATC-5

ATC-5ID

Tan

ATC-7-1/2

ATC-7-1/2ID

Brown

ATC-10

ATC-10ID

Red

ATC-15

ATC-15ID

Blue

ATC-20

ATC-20ID

Yellow

ATC-25

ATC-25ID

Clear

ATC-30

ATC-30ID

Green

ATC-35

ATC-35ID

Blue-Green

ATC-40

ATC-40ID

Orange

Available

With

Indication

Available

With

Indication

Non-Indicating

*Indicating

Low-Profile

Color

ATM-2

Gray

ATM-3

ATM-3ID

Violet

ATM-4

Pink

ATM-5

ATM-5ID

ATM-5LP

Tan

ATM-7-

1

/

2

ATM-7-

1

/

2

ID

ATM-7-

1

/

2

LP

Brown

ATM-10

ATM-10ID

ATM-10LP

Red

ATM-15

ATM-15ID

ATM-15LP

Blue

ATM-20

ATM-20ID

ATM-20LP

Yellow

ATM-25

ATM-25ID

ATM-25LP

Clear

ATM-30

ATM-30ID

ATM-30LP

Green

0.78"

0.91"

0.5"

0.38" 0.30"

4.0" + 0.25"

4.0" + 0.25"

1.125"

0.364"

0.25"

Data Sheet: 2107

Specifications

Description:

In-line fuse holders for

ATC

Blade-Type fuses.

Dimensions:

See Dimensions

illustration.

Ratings:

Volts: — 32Vdc

Amps:— 80% continuous of fuse

rating. See Catalog Numbers
table for individual fuses sizes.

Catalog Numbers

Catalog

Fuse Holder

Fuse

Electrical

Numbers

Description

Amps Connection

HHC

Yellow

1-20

#16 black leadwire

HHD

Black

1-30

#12 yellow leadwire

HHF

Black w/ cover

1-20

#16 yellow leadwire

HHG

Black w/ cover

1-30

#12 yellow leadwire

ATC-FHID

Indicating Holder

1-20

#16 black leadwire

Black w/ cover

A fuse must be properly and fully inserted into the holder to
provide a solid connection. Poor or improper insertion of the
fuse can result in failure of the fuse and holder, thus not
protecting the device for which it was intended.

HHC & HHD Dimensions - in

HHC, HHD, HHF, HHG &
ATC-FHID

easy

ID™ LED Indicating Holder

LED Indicator

*Call Bussmann Customer Satisfaction for ordering information.

*Call Bussmann Customer Satisfaction for ordering information.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

83

Low Voltage Supplementary Fuses

Automotive Blade-type Fuses & Holders

Data Sheet: 2129

Data Sheet: 2128

Specifications

Description: 

In-line fuse holders for

ATM Fuses.

Ratings:

Volts: — 32Vdc

Amps: — 80% continuous of fuse

rating. See Catalog Numbers
table for individual fuses
sizes.

Catalog Numbers

Catalog

Fuse Holder

Fuse Electrical

Numbers Description

Amps Connection

HHL

Black w/ cover

2-20 #16 black leadwire,

4˝ length stripped to 

1

/

4

˝

HHM

Black w/ cover

2-30 #12 red leadwire,

4˝ length stripped to 

1

/

4

˝

ATM-FHID

Indicating Holder

2-20 #16 black leadwire

Black w/ cover

A fuse must be properly and fully inserted into the holder to
provide a solid connection. Poor or improper insertion of the
fuse can result in failure of the fuse and holder, thus not
protecting the device for which it was intended.

HHL & HHM Dimensions - in

Specifications

Description: 

In-line fuse holders for

MAXI Fuses.

Ratings:

Volts: — 32Vdc

Amps: — 80% continuous of fuse 

rating. See Catalog Numbers
table for individual fuses
sizes.

Catalog Numbers

Catalog

Fuse Holder

Fuse

Electrical

Numbers Description

Amps

Connection

HHX

Black w/ cover

20-60

#6 red leadwire,

5˝ with blunt ends

A fuse must be properly and fully inserted into the holder to
provide a solid connection. Poor or improper insertion of the
fuse can result in failure of the fuse and holder, thus not
protecting the device for which it was intended.

Dimensions - in

HHX

HHL, HHM & ATM-FHID

1.56" 

4.75" 

4.75" 

.25" 

.25" 

.59" 

.41" 

3.35"

6.70"

6.70"

1.37"

.265" DIA. HOLE

easy

ID™ LED Indicating Holder

LED Indicator

Data Sheet: 2049

(Actual Size)

MAX Maxi–Fuse

Specifications
Description:

Fast-acting blade fuse.

Construction:

Colored plastic housing

with zinc fuse element.

Ratings:

Volts — 32Vdc

Amps — 20-80A (non-indicating)

20-100A (indicating)

IR — 1000A

Features and Benefits

• Color coded plastic housing for easy 

identification of fuse ratings

Typical Applications

• Automotive

Catalog Numbers (Amps)

Recommended in-line fuse holder for

blade type fuses

• Page 83

Available

With

Indication

Non-Indicating

*Indicating

Color

MAX-20

MAX-20ID

Yellow

MAX-25

Gray

MAX-30

MAX-30ID

Green

MAX-35

Brown

MAX-40

MAX-40ID

Orange

MAX-50

MAX-50ID

Red

MAX-60

MAX-60ID

Blue

MAX-70

MAX-70ID

Tan

MAX-80

MAX-80ID

Clear

MAX-100ID

Purple

Lo
w V

oltage

Supplementar

y

Fuses

*Call Bussmann Customer Satisfaction for ordering information.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

84

Low Voltage Supplementary Fuses

Automotive Blade-type PCB Fuseclips

Data Sheet: 2131

Data Sheet: 2131

Data Sheet: 2131

Catalog

Clip

Number

Mat.*

Finish

1A5600

Cart.

Satin 

Brass

Finish Tin

ATC Fuses (0 to 20 Amps)

1A5600 Series

Dimensional Data

ATM Fuses

1A5778 Series

Dimensional Data

1A5779 Series

1A5780 Series

Dimensional Data

.150"

(3.81mm)

.330"

(8.38mm)

.295"

(7.49mm)

.200"

(5.08mm)

.053"

(1.35mm)

0.08" 

±

 0.01"

(2.03 

± 

0.25mm)

.090"  

(2.29mm)

MOUNTING LAYOUT FOR 2 CLIPS

0.012

0.30

MATERIAL: BRASS, NICKEL PLATED,          THICK

1.90
0.075

0.156

3.96

0.440

11.18

4.98
0.196

0.125

3.18

1.57
0.062

0.062

1.57

2.18
0.086

3.66
0.144

(TYP-4)

1.65 ± 0.05

0.065 ± 0.002

DIA. HOLE

0.144

3.66

0.176

4.47

3.66
0.144

SPEC

I

F

I

CAT

I

ONS

. .  

. . . . . 

. . . . . 

. . . . . 

. . . . . . . .

MOUNT

I

NG LAYOUT

UL RATED 94V-0

BRASS, N

I

CKEL PLATED

GLASS F

I

LLED NYLON, 

500V AC

15 AMPS

145ºC
292ºF

TO

-50ºC
-58ºF

TEMPERATURE RAT

I

NG 

VOLTAGE RAT

I

NG 

CURRENT RAT

I

NG 

FUSECL

I

PS 

BASE MATER

I

AL

BASE

FUSECL

I

PS

14.68

0.578

4.75
0.187

1.45
0.057

3.18
0.125

1.24
0.049

0.340

8.64

0.100

2.54

0.062

1.57

3.66
0.144

(TYP-4)

1.65 

±

 0.05

0.065 

±

 0.002

D

I

A. HOLE

0.144

3.66

0.176

4.47

3.66
0.144

292ºF

-58ºF

SPEC

I

F

I

CAT

I

ONS

. .  

. . . . . 

. . . . . 

. . . . . 

. . . . . . . .

MOUNT

I

NG LAYOUT

UL RATED 94V-0

BRASS, N

I

CKEL PLATED

GLASS F

I

LLED NYLON, 

500V AC

15 AMPS

145ºC

TO

-50ºC

TEMPERATURE RAT

I

NG 

VOLTAGE RAT

I

NG 

CURRENT RAT

I

NG 

FUSECL

I

PS 

BASE MATER

I

AL

 

 

19.30

0.760

3.18
0.125

5.08
0.200

BASE

FUSECL

I

PS

4.45
0.175

6.35
0.250

0.271

6.88

0.437

11.10

0.050

1.27

(TYP-4)

2.54 

±

 0.05

0.100 

±

 0.002

D

I

A. HOLE

0.200

5.08

0.160

4.06

*Spg. Br. - Spring Bronze; BeCu - Beryllium Copper; Cart. Brass - Cartridge Brass

***For RoHS compliant version add “-R” option code suffix to part number.

Data Sheet: 2131

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

85

Electronic

Fuses

Electronic  - PC Board
and Small Dimension
Fuses & Accessories

Section Contents

Page

5 x 15mm ferrule fuses . . . . . . . . . . . . . . . . . . . . . .   86

5 x 20mm European (IEC) ferrule fuses . . . . . . . . 87-88

5 x 20mm North American (UL) ferrule fuses . . . . .

89

1

4

˝ Dia. x 

5

8

˝ to 1˝ length ferrule fuses  . . . . . . . . . . .

90

1

4

˝ Dia. x 1 

1

4

˝ length fast-acting ferrule fuses . . . . . . 91

1

4

˝ Dia. x 1 

1

4

˝ length time-delay ferrule fuses . . . . . . 92

PCB mount fuse holders . . . . . . . . . . . . . . . . . . . 93-94

PCB fuseclips for 5mm dia. fuses . . . . . . . . . . . . . . 95

PCB fuseclips for 

1

4

˝ dia. fuses . . . . . . . . . . . . . . . 96-97

PCB fuseclips for 

1

4

˝, 

9

32

˝, 

13

32

˝ & 

9

16

˝ fuses  . . . . . . . .

98

Scan this tag to get the

latest product information for 

Electronic Fuses and Accessories.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

C517 (axial leads)

Specifications
Description:

Fast-acting

fuse.

Construction:

Glass tube.

Ratings:

Volts — 350Vac*

— 32Vdc (Self

Certified)

Amps — 3A

IR — 100A @ 350Vac 

— 100A @

250Vac 

— 10kA @

125Vac

*350Vac/100A IR is UL Recognized

Agency Information:

CE, UL Listing

File E19180, Guide JDYX, CSA
Certification File 53787, Class  
1422-01, UL Recognized, File
E19180, Guide JDYX2.

• Small footprint saves space in 

equipment.

• Fast-acting for maximum component

protection.

• 350Vac rating for 277V ballast circuit

protection.

Typical Applications

• Electronic Circuits
• Printed Circuit Boards
• Electronic Ballast Protection

Catalog Number (Amps)

With Axial Leads

C517-3-R

C518 (axial leads)

C520

Specifications
Description:

Fast-acting fuse.

Dimensions:

5 x 15mm 

(0.197” X 0.591”).

Construction:

Glass tube.

Ratings:

Volts — 250Vac

— 32Vdc (Self

Certified)

Amps — 100mA-5A

IR — 35A (100mA-750mA @

250Vac)

— 10kA (100mA-5A @ 125Vac) 

— 100A (1.5-3.5A @ 250Vac)

— 200A (4-5A @ 250Vac)

Agency Information:

CE,

UL Recognized File E19180, Guide 
JDYX2CSA Certification File 53787,
Class 1422-01.

Features and Benefits

• Small footprint saves space in

equipment.

• Fast-acting for maximum component

protection.

• Available in ferrule and axial leaded 

configurations

Typical Applications

• Electronic Circuits
• Printed Circuit Boards

Catalog Numbers (Amps)

With Axial Leads

C518-100-R

C518-750-R

C518-4-R

C518-125-R

C518-2-R

C518-5-R

C518-250-R

C518-2.5-R

C518-375-R

C518-3-R

C518-500-R

C518-3.5-R

Without Axial Leads

C520-100-R

C520-750-R

C520-3.5-R

C520-125-R

C520-1.5-R

C520-4-R

C520-250-R

C520-2-R

C520-5-R

C520-375-R

C520-2.5-R

C520-500-R

C520-3-R

C515 (axial leads)

C519

Specifications
Description:

Time-delay fuse.

Dimensions:

5 x 15mm 

(0.197” X 0.591”).

Construction:

Glass tube.

Ratings:

Volts — 125Vac (3.5-

7A)

— 250Vac

(125mA-3A)

— 32Vdc (Self Certified)

Amps — 125mA-7A

IR — 25A (350mA @ 600Vac)

— 35A (125mA-1A @ 250Vac) 

— 100A (1.25-3A @ 250Vac) 

— 400A (3.5-7A @ 125Vac)

— 10kA (125mA-3A @ 125Vac) 

Agency Information:

CE, UL Listed

File E19180, Guide JDYX 
125mA-250mA and 375mA-3A, UL
Recognized, File E19180, Guide
JDYX2, 350mA and 3.5A-7A, CSA
Certification File 53787, Class 
1422-01, 125mA-250mA and 
375mA-3A.

Features and Benefits

• Time-delay for closer sizing on

inductive circuits.

Typical Application

• Electronic Circuits
• Printed Circuit Boards

Catalog Numbers (Amps)

With Axial Leads

C515-125-R

C515-800-R

C515-2.5-R

C515-250-R

C515-1-R

C515-3-R

C515-350-R

C515-1.25-R

C515-3.5-R

C515-375-R

C515-1.5-R

C515-4-R

C515-500-R

C515-1.6-R

C515-5-R

C515-600-R

C515-2-R

C515-6-R

C515-750-R

C515-2.25-R

C515-7-R

Without Axial Leads

C519-125-R

C519-750-R

C519-2.25-R

C519-250-R

C519-1-R

C519-2.5-R

C519-350-R

C519-1.25-R

C519-3-R

C519-375-R

C519-1.5-R

C519-3.5-R

C519-500-R

C519-1.6-R

C519-4-R

C519-600-R

C519-2-R

C519-5-R

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

86

Electronic — PCB & Small Dimension Fuses

5 x 15mm Ferrule Fuses

Data Sheet: 2025

Data Sheet: 2026 (C518) & 2027 (C520)

Data Sheet: 2006 (C515) & 2007 (C519)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

87

Electronic

Fuses

5 x 20mm European (IEC) Ferrule Fuses

S500-V (GDB-V)* 

(axial leads)

S500 (GDB)*

Specifications
Description:

Fast-

acting, low-breaking
capacity fuse.

Construction:

Glass tube, nickel-
plated brass endcaps
(silver-plated end-
caps, 32-125mA).

Ratings:

Volts — 250Vac (or less)

— 32Vdc (Self Certified)

Amps — 32mA-10A

IR — See catalog table

Agency Information:

CE, cURus,

SEMKO, VDE, BSI, IMQ, CCC.
See data sheet for complete agency 
information. Not all approvals apply to all
ratings.

Features and Benefits

• Fast-acting for maximum protection,

conforms to IEC 60127-2 (160mA-10A).

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

Catalog

IR

Max Voltage

Numbers

(Amps)

I2t

Drop (mV)

S500-32-R

35

0.000047

3200

S500-40-R

35

0.00011

2500

S500-50-R

35

0.00020

2400

S500-63-R

35

0.00057

2000

S500-80-R

35

0.0012

1200

S500-100-R

35

0.003

1100

S500-125-R

35

0.005

1000

S500-160-R

35

0.008

2000

S500-200-R

35

0.016

1700

S500-250-R

35

0.028

1400

S500-315-R

35

0.058

1300

S500-400-R

35

0.018

1100

S500-500-R

35

0.018

220

S500-630-R

35

0.035

220

S500-800-R

35

0.067

190

S500-1-R

35

0.60

200

S500-1.25-R

35

0.84

200

S500-1.6-R

35

1.6

190

S500-2-R

35

4.2

150

S500-2.5-R

35

6.1

150

S500-3.15-R

35

13

130

S500-4-R

40

22

130

S500-5-R

50

42

120

S500-6.3-R

63

69

120

S500-8-R

80

-

120

S500-10-R

100

—-

120

Options

Axial leads, put “V” in P/N, 
*When ordering GDB version, do not
add “-R” suffix to part number.

S501-V (GDA-V)* 

(axial leads)

S501 (GDA)*

Specifications
Description:

Fast-

acting, high-breaking
capacity fuse.

Construction:

Ceramic tube, 

nickel-plated brass

endcaps (silver-

plated endcaps 50mA-400mA).

Ratings:

Volts — 250Vac (or less)

— 32Vdc (Self Certified)

Amps — 50mA-10A**

IR — 1500A @ 250Vac

Agency Information:

CE, cURus,

SEMKO, VDE, IMQ, CCC, CSA, BSI.

See data sheet for complete agency infor-
mation. Not all approvals apply to all ratings.

Features and Benefits

• Fast-acting for maximum protection.
• High break capacity for use in higher

fault energy electronic circuitry.

• Conforming to IEC standards.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

Catalog

Typical Voltage

Numbers

I2t

Drop (mV)

S501-50-R

0.0017

9000

S501-63-R

0.0005

3300

S501-80-R

0.0011

2600

S501-100-R

0.0018

2300

S501-125-R

0.0037

1900

S501-160-R

0.008

1600

S501-200-R

0.020

1350

S501-250-R

0.027

1300

S501-315-R

0.010

1400

S501-400-R

0.018

1200

S501-500-R

0.038

1050

S501-630-R

0.064

1200

S501-800-R

0.097

490

S501-1-R

0.146

330

S501-1.25-R

0.313

297

S501-1.6-R

0.748

239

S501-2-R

2.0

205

S501-2.5-R

3.9

190

S501-3.15-R

8.1

160

S501-4-R

14

160

S501-5-R

25

155

S501-6.3-R

48

150

S501-8-R

N/A

N/A

S501-10-R

N/A

N/A

Options

Axial leads, put “V” in P/N.  
*When ordering GDA version, do not
add “-R” suffix to part number. 

**GDA is not available above 6.3A.

Data Sheet: 2052 (S500), 2015 (GDB)

Data Sheet: 2051 (S501), 2014 (GDA)

S505-V 

(axial leads)

S505

Specifications
Description:

Time-

delay, high-breaking
capacity fuse.

Construction:

Ceramic tube, silver-
plated brass endcaps.

Ratings:

Volts — 250Vac (or less)

— 32Vdc (Self 

Certified)

Amps — 500mA-12A

IR — 1500A @ 250Vac

Agency Information:

UL, CSA,

SEMKO, VDE, BSI, IMQ, PSE/JET,
CCC, EK, FIMKO.

See data sheet for complete agency
information. Not all approvals apply 
to all ratings.

Features and Benefits

• Time-delay performance ideal for

inductive circuits.

• Conforming to IEC standards.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

Catalog

Typical

Max Voltage

Numbers

I2t

Drop (mV)

S505-500-R

0.188*

295

S505-800-R

0.632*

189

S505-1-R

1.28

152.5

S505-1.25-R

2.22

150

S505-1.6-R

6.78

125

S505-2-R

9.60

118.5

S505-2.5-R

16.60

115

S505-3.15-R

36.60

102.5

S505-4-R

38.45*

86.5

S505-5-R

71.30*

77.5

S505-6.3-R

197

75

S505-8-R

311

75

S505-10-R

397

72

S505-12-R

713.7*

77

*The typical I

2

t value was measured at 10 times of rated

current under DC.

Options

Axial leads, put “V” in P/N.

Data Sheet: 2037

Electronic — PCB & Small Dimension Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

88

Electronic — PCB & Small Dimension Fuses

5 x 20mm European (IEC) Ferrule Fuses

S506-V (GDC-V)* 

(axial leads)

S506 (GDC)*

Specifications
Description:

Time-

delay, low-breaking
capacity fuse.

Construction:

Glass

tube, nickel-plated
brass endcaps.

Ratings:

Volts — 250Vac (or less)

— 32Vdc (Self Certified)

Amps — 32mA-15A**

IR — 35A @ 250Vac

Agency Information:

UR, CSA,

cURus, SEMKO, VDE, BSI, IMQ,
PSE/JET, CCC.

See data sheet for complete agency
information. Not all approvals apply to all
ratings.

Features and Benefits

• Time-delay compatibility for inductive circuits
• Conforming to IEC standards

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

Catalog

Typical

Max Voltage

Numbers

I2t

Drop (mV)

S506-32-R

0.0051

1050

S506-40-R

0.0072

920

S506-50-R

0.0095

800

S506-63-R

0.021

760

S506-80-R

0.038

580

S506-100-R

0.045

490

S506-125-R

0.063

390

S506-160-R

0.093

320

S506-200-R

0.114

340

S506-250-R

0.265

270

S506-315-R

0.621

250

S506-400-R

0.872

210

S506-500-R

0.827

140

S506-630-R

1.33

150

S506-800-R

2.78

75

S506-1-R

6.45

87.5

S506-1.25-R

10.05

86

S506-1.6-R

21.7

82

S506-2-R

31.6

77

S506-2.5-R

59.4

72.5

S506-3.15-R

96.4

68.5

S506-4-R

71.8

67

S506-5-R

142.5

60.5

S506-6.3-R

237.6

54

S506-8-R

255.8

55

S506-10-R

450

54

S506-12.5-R

1019.5

45

S506-15-R

1091.7

65.5

Options

Axial leads, put “V” in P/N.
*When ordering GDC version, do not add 
“-R” suffix to part number.
**GDC series is not available above 6.3A.

Data Sheet: 2016 (GDC), 4332 (S506)

S505H (S505H-V)* 

(axial leads)

Specifications
Description:

Time-

delay, high-breaking
capacity fuse.

Construction:

Ceramic tube, nickel-
plated brass endcaps.

Ratings:

Volts — 600Vac/400Vdc

— 500mA-5A

— 6.3A-10A

— 500Vac/400Vdc

Amps — 500mm-10A

IR — 35A @ 250Vac

Agency Information:

cURus, CCC,

CQC, TUV, PSE/JET.

See data sheet for complete agency
information. Not all approvals apply to all
ratings.

Features and Benefits

• Time-delay, high breaking capacity
• Conforming to IEC standards

Typical Applications

• Power supplies - adapters
• Desktops/notebooks

Catalog Numbers (Amps)

Catalog

Typical

Max Voltage

Numbers

I2t (A

2

s)

1

Drop (mV)

3

S505H-500-R

0.188

295

S505H-800-R

0.632

189

S505H-1-R

1.28

153

S505H-1.25-R

2.22

150

S505H-1.6-R

6.78

125

S505H-2-R

11.44

128

S505H-2.5-R

24.23

126

S505H-3.15-R

43.55

121

S505H-4-R

38.45

90

S505H-5-R

71.3

89

S505H-6.3-R

111.4

80

S505H-8-R

228.2

76

S505H-10-R

349.5

72

1.

Typical Pre-Arc I

2

t: Measured at 10In DC.

2.

- Breaking Capacity of 250VAC/1500A is tested by all agency

approvals, test condition is 250Vac, PF: 0.7-0.8.

- Breaking Capacity of Max. voltage is tested by UL, PF:1.
- Breaking Capacity Test of DC is tested by UL under Capacitor Bank

4800mF (for 400V, 1500A) 2400mF (for 400V, 500A).

3.

Typical Voltage Drop: Voltage drop is measured under ambient 20°C
with rated current.

Options

Axial leads, put “V” in P/N.

Data Sheet: 4406

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

89

Electronic

Fuses

GMD-V (axial leads)

GMD

Specifications
Description:

Time-

delay fuse.

Dimensions:

5 x 20mm 
(0.197” x 0.788”).

Construction:

Glass tube, nickel-
plated brass 
endcaps.

Ratings:

Volts — 250Vac

— 32Vdc (Self Certified)

Amps — 125mA-4A

IR —  10kA (125mA-3A @ 125Vac,

p.f. = 0.7-0.8)

—  10kA (4A @ 125Vac, 

p.f. = 1.0)

— 35A (125mA-1A @ 250Vac,

p.f. = 0.7-0.8)

— 100A (1.2A-3.A @ 250Vac,

p.f. = 0.7-0.8)

— 200A (4A @ 250Vac, 

p.f. = 1.0)

Agency Information:

CE, UL Listed

Guide JDYX, File E19180, 125mA-3A,
UL Recognized, Guide JDYX2, File
E19180, 4A, CSA Certified, Class
1422-01, File 53787, 0-4A, PSE/JET.
File 1641-31003-1001, 1.2A-4A.

Features and Benefits

• Time-delay compatibility for inductive circuits.
• Conforming to UL standards.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

With Axial Leads

GMD-V-125-R

GMD-V-500-R

GMD-V-1.5-R

GMD-V-150-R

GMD-V-600-R

GMD-V-1.6-R

GMD-V-200-R

GMD-V-630-R

GMD-V-2-R

GMD-V-250-R

GMD-V-750-R

GMD-V-2.5-R

GMD-V-300-R

GMD-V-800-R

GMD-V-3-R

GMD-V-315-R

GMD-V-1-R

GMD-V-4-R

GMD-V-375-R

GMD-V-1.2-R

GMD-V-400-R

GMD-V-1.25-R

Without Axial Leads

GMD-125-R

GMD-500-R

GMD-1.5-R

GMD-150-R

GMD-600-R

GMD-1.6-R

GMD-200-R

GMD-630-R

GMD-2-R

GMD-250-R

GMD-750-R

GMD-2.5-R

GMD-300-R

GMD-800-R

GMD-3-R

GMD-315-R

GMD-1-R

GMD-4-R

GMD-375-R

GMD-1.2-R

GMD-400-R

GMD-1.25-R

GMC-V (axial leads)

GMC

Specifications
Description:

Medium

time-delay fuse.

Dimensions:

5 x 20mm

(0.197” x 0.788”).

Construction:

Glass

tube, nickel-plated brass
endcaps.

Ratings:

Volts — 250Vac (63mA-

3.15A)

— 125Vac (3.5-10A)

— 32Vdc (Self Certified)

Amps — 63mA-10A

IR —  35A (63mA- 1A @ 250Vac,

p.f. = 0.7-0.8)

— 10kA (63mA-6A @ 125Vac, p.f.

= 0.7-0.8)

— 100A (1.25-3.15A @ 250Vac,

p.f. = 0.7-0.8)

— 200A (6.3-10A @ 125Vac, p.f.

= 1.0)

Agency Information:

CE, Std. 248-14,

UL Listed Guide JDYX, File E19180, 
0-6.3A, UL Recognized, Guide JDYX2,
File E19180, 7-8A, CSA Certified, Class
1422-01, File 53787, 0-6.3A.

Features and Benefits

• Conforming to UL standards.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

With Axial Leads

GMC-V-63-R

GMC-V-500-R

GMC-V-2.5

GMC-V-80-R

GMC-V-600-R

GMC-V-3.15

GMC-V-100-R

GMC-V-630-R

GMC-V-3.5

GMC-V-125-R

GMC-V-750-R

GMC-V-4

GMC-V-150-R

GMC-V-800-R

GMC-V-5

GMC-V-200-R

GMC-V-1-R

GMC-V-6

GMC-V-250-R

GMC-V-1.25-R

GMC-V-6.3

GMC-V-300-R

GMC-V-1.5-R

GMC-V-7

GMC-V-315-R

GMC-V-1.6-R

GMC-V-8

GMC-V-400-R

GMC-V-2-R

GMC-V-10

Without Axial Leads

GMC-63mA

GMC-500-R

GMC-2.5-R

GMC-80mA

GMC-600-R

GMC-3.15-R

GMC-100mA

GMC-630-R

GMC-3.5-R

GMC-125mA

GMC-750-R

GMC-4-R

GMC-150mA

GMC-800-R

GMC-5-R

GMC-200mA

GMC-1-R

GMC-6-R

GMC-250mA

GMC-1.25-R

GMC-6.3-R

GMC-300mA

GMC-1.5-R

GMC-7-R

GMC-315mA

GMC-1.6-R

GMC-8-R

GMC-400mA

GMC-2-R

GMC-10-R

GMA-V (axial leads)

GMA

Specifications
Description:

Fast-acting fuse.

Dimensions:

5 x 20mm
(0.197” x 0.788”).

Construction:

Glass tube,
nickel-plated brass
endcaps.

Ratings:

Volts — 250Vac (63mA-2.5A)

— 125Vac (3.15-15A)

— 32Vdc (Self Certified)

Amps — 63mA-15A

IR — 35A (63mA- 1A @ 250Vac,

p.f. = 0.7-0.8)

— 10kA (63mA-6A @ 125Vac,

p.f. = 0.7-0.8)

— 100A (1.25-2.5A @ 250Vac,

p.f. = 0.7-0.8)

— 200A (7-8A @ 125Vac, p.f. = 1.0)

— 150A (10-15A @ 125Vac,

p.f. = 1.0)

Agency Information:

CE, Std.

248-14 UL Listed Guide JDYX, File
E19180, 0-6A, UL Recognized, Guide
JDYX2, File E19180, 7-15A, CSA
Certified, Class 1422-01,File 53787, 0-6.

Features and Benefits

• Fast-acting for maximum protection.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

With Axial Leads

GMA-V-63-R

GMA-V-800-R

GMA-V-4-R

GMA-V-100-R

GMA-V-1-R

GMA-V-5-R

GMA-V-125-R

GMA-V-1.25-R

GMA-V-6-R

GMA-V-200-R

GMA-V-1.5-R

GMA-V-7-R

GMA-V-250-R

GMA-V-1.6-R

GMA-V-8-R

GMA-V-300-R

GMA-V-2-R

GMA-V-10-R

GMA-V-500-R

GMA-V-2.5-R

GMA-V-15-R

GMA-V-600-R

GMA-V-3.15-R

GMA-V-750-R

GMA-V-3.5-R

Without Axial Leads

GMA-63-R

GMA-800-R

GMA-4-R

GMA-100-R

GMA-1-R

GMA-5-R

GMA-125-R

GMA-1.25-R

GMA-6-R

GMA-200-R

GMA-1.5-R

GMA-7-R

GMA-250-R

GMA-1.6-R

GMA-8-R

GMA-300-R

GMA-2-R

GMA-10-R

GMA-500-R

GMA-2.5-R

GMA-15-R

GMA-600-R

GMA-3.15-R

GMA-750-R

GMA-3.5-R

5 x 20mm North American (UL) Ferrule Fuses

Data Sheet:2019

Data Sheet: 4395

Data Sheet: 2017

GMC-10A

GMD

Electronic — PCB & Small Dimension Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

90

Electronic — PCB & Small Dimension Fuses

1

4

˝ Dia. x 

5

8

˝ to 1˝ Length Ferrule Fuses

AGX

Specifications
Description:

Fast-acting

fuse.

Dimensions:

1

4

˝ x 1˝ 

(6.4 x 25.4mm).

Construction:

Glass tube.

Ratings:

Volts — 250Vac (

1

16

-20A)

— 125Vac (25-30A)

— 32Vdc (

1

16

-30A)

Amps — 

1

16

-30A

IR — 35A (

1

16

-1A @ 250Vac)

— 10kA (

1

16

-10A @ 125Vac)

— 200A (15-20A @ 125Vac)

— 100A (25-30A @ 125Vac)

— 1000A (8-30A @ 32Vac)

Agency Information:

cULus: AGX 

0-10A (Guide JDYX, File E 19180 and

Guide JDYX7, File E19180), UL
Recognized Card: AGX 15-30A (Guide
JDYX2, File E19180), CSA Component
Acceptance Card : AGX 15-30A (Class
No. 1422-01, File 53787)

Features and Benefits

• Size rejects insertion of other fuse types.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

AGX-

1

4

AGX-1-

1

2

AGX-8

AGX-

3

10

AGX-2

AGX-10

AGX-

3

8

AGX-2-

1

2

AGX-15

AGX-

4

10

AGX-3

AGX-20

AGX-

1

2

AGX-4

AGX-25

AGX-

3

4

AGX-5

AGX-30

AGX-1

AGX-6

AGX-1-

1

4

AGX-7

AGA

Specifications
Description:

Fast-acting

fuse.

Dimensions:

1

4

˝ x 

5

8

˝ 

(6.4 x 15.9mm).

Construction:

Glass tube.

Ratings:

Volts — 125Vac (or less)

— 32Vdc (Self Certified)

Amps — 1-30A

IR — 10kA (1-1

1

2

A @ 125Vac)

— 200A (2-5A @ 125Vac)

— 1000A (6-30A @ 32Vac)

Agency Information:

CE, Std. 248-

14, UL File E19180, UL Listed, Guide
JDYX 0-3

1

2

A UL Recognized, Guide

JDYX2 12-30A.

Features and Benefits

• Fast-acting for maximum protection.
• Size rejects insertion of other fuse

types.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

AGA-1

AGA-5

AGA-15

AGA-1-

1

2

AGA-6

AGA-20

AGA-2

AGA-7

AGA-25

AGA-2-

1

2

AGA-7-

1

2

AGA-30

AGA-3

AGA-10

AGW

Specifications
Description:

Fast-acting

fuse.

Dimensions:

1

4

˝ x 

7

8

˝ 

(6.4 x 22.2mm).

Construction:

Glass

tube.

Ratings:

Volts — 32Vac

— 32Vdc (Self Certified)

Amps — 1-30A

Features and Benefits

• Fast-acting for maximum protection.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

AGW-1

AGW-4

AGW-15

AGW-1-

1

2

AGW-5

AGW-20

AGW-2

AGW-6

AGW-25

AGW-2-

1

2

AGW-7-

1

2

AGW-30

AGW-3

AGW-10

Data Sheet: 2040

Data Sheet: 2039

Data Sheet: 2041

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

91

GBB (GBB-V axial leads)

Specifications
Description:

Very

fast-acting fuse.

Dimensions:

1

4

˝ x 1 

1

4

˝ 

(6.4 x 31.7mm).

Construction:

Ceramic cartridge with

nickel-plated brass

endcaps.

Ratings:

Volts — 250Vac/125Vdc

Amps — 1-30A

IR — 200A @ 250Vac

— 200A (20-30A @ 125Vac/dc)

— 10,000A (1A -15A @

125Vac/dc)

Agency Information:

CE, Std. 248-14, UL Recognized, 
1-30,125Vdc/250Vac, File E56412,
Guide JFHR2, CSA Accepted, 1-30,
125Vdc/250Vac, File 53787, Class
1422-30.

Features and Benefits

• Very fast-acting performance allows

protection of highly sensitive 
electronic circuitry.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

With Axial Leads

GBB-V-1-R

GBB-V-6-R

GBB-V-15-R

GBB-V-1-

1

4

-R

GBB-V-7-R

GBB-V-20-R

GBB-V-2-R

GBB-V-8-R

GBB-V-25-R

GBB-V-3-R

GBB-V-9-R

GBB-V-30-R

GBB-V-4-R

GBB-V-10-R

GBB-V-5-R

GBB-V-12-R

Without Axial Leads

GBB-1-R

GBB-6-R

GBB-15-R

GBB-1-

1

4

-R

GBB-7-R

GBB-20-R

GBB-2-R

GBB-8-R

GBB-25-R

GBB-3-R

GBB-9-R

GBB-30-R

GBB-4-R

GBB-10-R

GBB-5-R

GBB-12-R

Data Sheet: 2013

ABC (ABC-V axial leads)

Specifications
Description:

Fast-acting fuse.

Dimensions:

1

4

˝ x 1 

1

4

˝  (6.4 x 31.7mm).

Construction:

Ceramic tube

with nickel-plated brass endcaps.

Ratings:

Volts — 250Vac/125Vdc 

(

1

4

-15A, 20-30A)

*

— 250Vac (18A)

— 32Vdc (Self Certified) 

Amps — 

1

4

-30A

IR** — 35A (

1

4

-1A @ 250Vac)

— 100A (1

1

2

-3A @ 250Vac)

— 200A (4-10A @ 250Vac)

— 750A (12-15A @ 250Vac)

— 400A (18-20A @ 250Vac)

— 10kA (

1

4

-15A @ 125Vac)

— 1kA (18-30A @ 125Vac)

— 10kA (

1

4

-15, 20A @ 125Vdc)

— 400A (25-30A @ 125Vdc)

— 200A (25-30A @ 250Vac)

*CSA approvals for 25A and 30A are at 125Vac – IR 1000A and Vdc  – IR 400A
(IR 1000A at 75Vdc)
**Interrupting ratings measured at 70% – 80% power factor on AC. The 
interrupting ratings for 18A and 20A were measured at 85%-95% power factor
on AC. The interrupting ratings for 25A and 30A were measured at 89% power
factor on AC.

Agency Information:

CE, Std. 248-14

UL Listed, Guide JDYX File E19180, 

1

4

-15A; UL Recognized, Guide JDYX2,

File E19180, 18-30A; CSA Certification,
Class 1422-01 & 1422-30, File 53787, 

1

4

-30A.

Features and Benefits

• Ceramic body allows for higher

amp/volt rating combinations.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

With Axial Leads

ABC-V-

1

4

-R

ABC-V-3-R

ABC-V-12-R

ABC-V-

1

2

-R

ABC-V-4-R

ABC-V-15-R

ABC-V-

3

4

-R

ABC-V-5-R

ABC-V-18-R

ABC-V-1-R

ABC-V-6-R

ABC-V-20-R

ABC-V-1-

1

2

-R

ABC-V-7-R

ABC-V-25-R

ABC-V-2-R

ABC-V-8-R

ABC-V-30-R

ABC-V-2-

1

2

-R

ABC-V-10-R

Without Axial Leads

ABC-

1

4

-R

ABC-3-R

ABC-12-R

ABC-

1

2

-R

ABC-4-R

ABC-15-R

ABC-

3

4

-R

ABC-5-R

ABC-18-R

ABC-1-R

ABC-6-R

ABC-20-R

ABC-1-

1

2

-R

ABC-7-R

ABC-25-R

ABC-2-R

ABC-8-R

ABC-30-R

ABC-2-

1

2

-R

ABC-10-R

AGC (AGC-V axial leads)

Specifications
Description:

Fast-acting fuse.

Dimensions:

1

4

˝ x 1 

1

4

˝

(6.4 x 31.7mm).

Construction:

Glass

tube with nickel-plated

brass endcaps.

Ratings:

Volts — 250Vac (

1

20

-10A)

— 32Vac (12-30A)

— 32Vdc (Self Certified)

Amps — 

1

20

-30A

IR — 35A (

1

20

-1A @ 250Vac)

— 100A (1

1

4

-3A @ 250Vac)

— 200A (4-10A @ 250Vac)

— 10kA (

1

20

-10A @ 125Vac)

— 1000A (12-30A @ 32Vac)

Agency Information:

CE, UL Listed,

Guide JDYX, File E19180, 0-10A UL
Recognized, Guide JDYX2, File
E19180, 12-30A CSA Certification,
Class 1422-01, File 053787, 

1

20

-30A.

Features and Benefits

• Original electronic glass tube fuse.
• Fast-acting for maximum protection.
• Wide amp/volt ratings allow versatility

of protecting electronic circuits.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

With Axial Leads

AGC-V-

1

20

-R

AGC-V-1-

1

4

-R

AGC-V-8-R

AGC-V-

1

10

-R

AGC-V-1-

1

2

-R

AGC-V-9-R

AGC-V-

1

8

-R

AGC-V-2-R

AGC-V-10-R

AGC-V-

3

16

-R

AGC-V-2-

1

4

-R

AGC-V-12-R

AGC-V-

2

10

-R

AGC-V-2-

1

2

-R

AGC-V-14-R

AGC-V-

1

4

-R

AGC-V-3-R

AGC-V-15-R

AGC-V-

3

10

-R

AGC-V-4-R

AGC-V-20-R

AGC-V-

3

8

-R

AGC-V-5-R

AGC-V-25-R

AGC-V-

1

2

-R

AGC-V-6-R

AGC-V-30-R

AGC-V-

3

4

-R

AGC-V-7-R

AGC-V-1-R

AGC-V-7-

1

2

-R

Without Axial Leads

AGC-

1

20

-R

AGC-1-

1

4

-R

AGC-8-R

AGC-

1

10

-R

AGC-1-

1

2

-R

AGC-9-R

AGC-

1

8

-R

AGC-2-R

AGC-10-R

AGC-

3

16

-R

AGC-2-

1

4

-R

AGC-12-R

AGC-

2

10

-R

AGC-2-

1

2

-R

AGC-14-R

AGC-

1

4

-R

AGC-3-R

AGC-15-R

AGC-

3

10

-R

AGC-4-R

AGC-20-R

AGC-

3

8

-R

AGC-5-R

AGC-25-R

AGC-

1

2

-R

AGC-6-R

AGC-30-R

AGC-

3

4

-R

AGC-7-R

AGC-1-R

AGC-7-

1

2

-R

1

4

˝ Dia. x 1 

1

4

˝ Length Fast-acting Ferrule Fuses

Data Sheet: 2000

Data Sheet: 2001

Electronic

Fuses

Electronic — PCB & Small Dimension Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

92

Electronic — PCB & Small Dimension Fuses

MDL-V (axial leads)

MDL

Specifications
Description:

Time-delay fuse.

Dimensions:

1

4

˝ x 1 

1

4

˝

(6.4 x 31.7mm).

Construction:

Glass

tube with nickel-plated

brass endcaps.

Ratings:

Volts — 250Vac (

1

16

-8A)

— 32Vac (9-30A)

— 32Vdc (Self Certified)

Amps — 

1

16

-30A

IR* — 35A (

1

16

-1A @ 250Vac)

— 100A (1

1

4

-3A @ 250Vac)

— 200A (4-8A @ 250Vac)

— 10000A (

1

16

-8A @ 125Vac)

— 1000A (9-30A @ 32Vac)

*Interrupting ratings were measured at 70% – 80% power
factor on AC, and at a time constant described in UL 198L.

Agency Information:

CE, UL Listed,

Guide JDYX, File E19180, 

1

16

-8A; CSA

Certification Class 1422-01, 

1

16

-8A; UL

Recognized, Guide JDYX2, File
E19180, 9-30A; CSA Component
Acceptance, Class 142230, 9-30A.

Features and Benefits

• Time-delay allows close sizing on

inductive circuits.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

With Axial Leads

MDL-V-

1

16

-R

MDL-V-1-R

MDL-V-7-R

MDL-V-

1

10

-R

MDL-V-1-

1

4

-R

MDL-V-8-R

MDL-V-

1

8

-R

MDL-V-1-

1

2

-R

MDL-V-9-R

MDL-V-

2

10

-R

MDL-V-2-R

MDL-V-10-R

MDL-V-

3

16

-R

MDL-V-2-

1

4

-R

MDL-V-12-R

MDL-V-

1

4

-R

MDL-V-2-

1

2

-R

MDL-V-15-R

MDL-V-

3

10

-R

MDL-V-3-R

MDL-V-20-R

MDL-V-

3

8

-R

MDL-V-4-R

MDL-V-25*

MDL-V-

1

2

-R

MDL-V-5-R

MDL-V-30*

MDL-V-

3

4

-R

MDL-V-6-R

Without Axial Leads

MDL-

1

16

-R

MDL-1-R

MDL-7-R

MDL-

1

10

-R

MDL-1-

1

4

-R

MDL-8-R

MDL-

1

8

-R

MDL-1-

1

2

-R

MDL-9-R

MDL-

2

10

-R

MDL-2-R

MDL-10-R

MDL-

3

16

-R

MDL-2-

1

4

-R

MDL-12-R

MDL-

1

4

-R

MDL-2-

1

2

-R

MDL-15-R

MDL-

3

10

-R

MDL-3-R

MDL-20-R

MDL-

3

8

-R

MDL-4-R

MDL-25*

MDL-

1

2

-R

MDL-5-R

MDL-30*

1

4

˝ Dia. x 1 

1

4

˝ Length Time-delay Ferrule Fuses

Data Sheet:2004

MDA-V (axial leads)

MDA

Specifications
Description:

Time-delay fuse.

Dimensions:

1

4

˝ x 1 

1

4

˝ (6.35 x

31.75mm).

Construction:

Ceramic tube

with nickel-plated brass 
endcaps.

Ratings:

Volts — 250Vac (or less)

— 125Vdc (20A- 30A)
— 32Vdc (Self Certified)

Amps — 

1

4

-30A

IR** — 35A (

1

4

-1A @ 250Vac)

— 100A (1

1

2

-2A @ 250Vac)

— 200A (2

1

2

-10A @ 250Vac)

— 750A (12-15A @ 250Vac)
— 1500A (20-30A @ 250Vac)
— 10kA (

1

4

-30A @ 125Vac)

— 10kA (20-30A @ 125Vdc)

**Interrupting ratings were measured at 70% – 80% power 
factor on AC, and at a time constant described in UL 248.

Agency Information:

CE, Std. 248-14,

UL Listed, Guide JDYX, File E19180,
0-20A CSA Certification, Class 1422-01,
File 53787, 0-20A. UL Recognized,
Guide JDYX2, File E19180, 25-30A,
CSA Component Acceptance, Class
1422-30, 25-30A

Features and Benefits

• Ceramic body allows for higher

amp/volt rating combinations.

• Inventory consolidation by replacing

MDL fuses allows for reduced SKU
investment and minimizing potential for
misapplying fuse.

Typical Applications

• Electronic Circuits

Catalog Numbers (Amps)

With Axial Leads

MDA-V-

1

4

-R

MDA-V-3-R

MDA-V-12-R

MDA-V-

1

2

-R

MDA-V-4-R

MDA-V-15-R

MDA-V-

3

4

-R

MDA-V-5-R

MDA-V-20-R

MDA-V-1-R

MDA-V-6-R

MDA-V-25-R

MDA-V-1-

1

2

-R

MDA-V-7-R

MDA-V-30-R

MDA-V-2-R

MDA-V-8-R

MDA-V-2-

1

2

-R

MDA-V-10-R

Without Axial Leads

MDA-

1

4

-R

MDA-3-R

MDA-12-R

MDA-

1

2

-R

MDA-4-R

MDA-15-R

MDA-

3

4

-R

MDA-5-R

MDA-20-R

MDA-1-R

MDA-6-R

MDA-25A-R

MDA-1-

1

2

-R

MDA-7-R

MDA-30A-R

MDA-2-R

MDA-8-R

MDA-2-

1

2

-R

MDA-10-R

MDQ-V (axial leads)

MDQ

Specifications
Description:

Dual-element, 
time-delay fuse.

Dimensions:

1

4

˝ x 1 

1

4

˝

(6.4 x 31.7mm).

Construction:

Glass

tube with nickel-plated

brass endcaps.

Ratings:

Volts — 250Vac (

1

100

-7A)

— 32Vac (7

1

2

-15A)

— 32Vdc (Self Certified)

Amps — 

1

100

-15A

IR — 35A (

1

100

-1A @ 250Vac)

— 100A (1

1

4

-3A @ 250Vac)

— 200A (4-7A @ 250Vac)

— 1000A (7

1

2

-12A @ 32Vac)

Agency Information:

Std. 248-14, UL

Listed, File E19180; Guide JDYX, 

1

16

-7A

CSA Certification, File 47233, Class 
1422-01, 

1

16 

-7A, UL Recognized, Guide

JDYX2, File E19180, 7.1-30A.

Features and Benefits

• Dual-element design allows closer sizing

to inductive circuits than any other fuses.

Typical Applications

• Electronic Relay and Control Circuits

Catalog Numbers (Amps)

With Axial Leads

MDQ-V-

1

100

MDQ-V-

3

10

MDQ-V-1-

1

2

MDQ-V-5

MDQ-V-

1

32

MDQ-V-

3

8

MDQ-V-1-

6

10

MDQ-V-6

MDQ-V-

1

16

MDQ-V-

4

10

MDQ-V-1-

8

10

MDQ-V-6-

1

4

MDQ-V-

1

10

MDQ-V-

1

2

MDQ-V-2

MDQ-V-7

MDQ-V-

1

8

MDQ-V-

6

10

MDQ-V-2-

1

4

MDQ-V-7-

1

2

MDQ-V-

15

100

MDQ-V-

3

4

MDQ-V-2-

1

2

MDQ-V-8

MDQ-V-

175

1000

MDQ-V-

8

10

MDQ-V-2-

8

10

MDQ-V-9

MDQ-V-

3

16

MDQ-V-1

MDQ-V-3

MDQ-V-10

MDQ-V-

2

10

MDQ-V-1-

2

10

MDQ-V-3-

2

10

MDQ-V-12

MDQ-V-

1

4

MDQ-V-1-

1

4

MDQ-V-4

MDQ-15

Without Axial Leads

MDQ-

1

100

MDQ-

3

10

MDQ-1-

1

2

MDQ-5

MDQ-

1

32

MDQ-

3

8

MDQ-1-

6

10

MDQ-6

MDQ-

1

16

MDQ-

4

10

MDQ-1-

8

10

MDQ-6-

1

4

MDQ-

1

10

MDQ-

1

2

MDQ-2

MDQ-7

MDQ-

1

8

MDQ-

6

10

MDQ-2-

1

4

MDQ-7-

1

2

MDQ-

15

100

MDQ-

3

4

MDQ-2-

1

2

MDQ-8

MDQ-

175

1000

MDQ-

8

10

MDQ-2-

8

10

MDQ-9

MDQ-

3

16

MDQ-1

MDQ-3

MDQ-10

MDQ-

2

10

MDQ-1-

2

10

MDQ-3-

2

10

MDQ-12

MDQ-

1

4

MDQ-1-

1

4

MDQ-4

MDQ-15

Data Sheet: 2002

Data Sheet: 2044

*MDL-25 & MDL-30 are not available in RoHS compliant
construction. 

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

93

Electronic

Fuses

HTC-60M

PCB Stand-Off Mount

Specifications
Description:

Four-leg PCB stand-off

fuse holder.

Dimensions:

See Dimensions 

illustration.

Ratings:

Volts: — 250V

Amps: — 6.3A

Agency Information:

See Specifications table notes 1, 4.

Dimensions - in (mm)

HTC-50M

PCB Horizontal Mount

Specifications
Description:

PCB horizontal mount

bayonet cap and fuse holder.

Dimensions:

See Dimensions 

illustration.

Ratings:

See Specifications table.

Agency Information:

See Specifications table notes 1, 2.

Dimensions - in (mm)

HTC-45M

PCB Vertical Mount

Specifications
Description:

PCB vertical mount 

bayonet cap and fuse holder.

Dimensions:

See Dimensions 

illustration.

Ratings:

See Specifications table.

Agency Information:

See Specifications table notes 1, 2, 5.

Dimensions - in (mm)

PC Board Mount Fuse Holders

F U

SE

0.461"

(11.7mm)

1.303

"

(33.1mm)

0.512"

(13.0mm)

Printed Circuit 
Board

Dia. (Typ.)

0.051

  + 0.002" 

_   

( 1.30 + 0.05mm)

0.394"

(10.0mm)

Mounting Holes

F U

SE

0.461"

(11.7mm)

1.303"

(33.1mm)

0.512"

(13.0mm)

Printed Circuit 
Board

0.394"

(10.0mm)

Mounting Holes

"  

0.002" 

+

_

   

( 1.30 + 0.05mm)
            

 

Dia. (Typ.)

0.051

Data Sheet 2110

Data Sheet 2110

HTC-65M (4-Leg)

Data Sheet 2110

Electronic — PCB & Small Dimension Fuses

Specifications

Terminals

— Tin-plated brass with 3mm (HTC-35M, -55M)

and 4.8mm (HTC-70M).

Molded Materials

— High temperature thermoplastic that

meets the flammability ratings of UL 94VO; Glow Wire Test:
960°C per IEC 695-2-1.

Solderability

— In accordance with IEC 68-2-20.

Electrical

— Contact Resistance: _

<10mW; Insulation

Resistance: _

>10MW; Dielectric Strength _

>2000Vac.

Shock Safety

— PC2 (fuse holders).

Agency Information:

1) cURus: Guide 1ZLT2 & IZLT8, File E14853
2) VDE: 40004457
3) VDE: 40004458
4) VDE: 40004459
5) VDE: 40004463

.886"

(22.5mm)

.10

.138"

(3.5mm)

.354"

(9.0mm)

.551"

(3.5mm)

.102"

 

Dia. Hole

(2.6mm)

.051"

 

Dia. Hole

(1.3mm)

.591"

(15.0mm)

4

mm)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

94

Electronic — PCB & Small Dimension Fuses

HBH-I 

(for 

1

4

˝ x 1 

1

4

˝ fuses)

HBH-M 

(for 5 x 20mm fuses)

PCB Horizontal

Mount

Specifications
Description:

PCB

horizontal mount
fuse holder.

Dimensions:

See

Dimensions 
illustration.

Ratings:

See Specifications table.

Dimensions - in (mm)

HBV-I 

(for 

1

4

˝ x 1 

1

4

˝ fuses)

HBV-M 

(for 5 x 20mm fuses)

PCB Vertical Mount

with Stability Pins

Specifications
Description:

PCB

vertical mount fuse
holder with stability
pins.

Dimensions:

See

Dimensions illustration.

Ratings:

See Specifications
table.

Dimensions - in (mm)

HBW-I 

(for 

1

4

˝ x 1 

1

4

˝ fuses)

HBW-M 

(for 5 x 20mm fuses)

PCB Vertical Mount

without Stability

Pins

Specifications
Description:

PCB

vertical mount fuse
holder without stability
pins.

Dimensions:

See Dimensions 

illustration.

Ratings:

See Specifications table.

Dimensions - in (mm)

PC Board Mount Fuse Holders

HBV

0.510"

(13.0mm)

1.855"

(47.0mm)

0.040"

(1.05mm)

0.580"

(14.9mm)

0.200"

(5.0mm)

0.200"

(5.0mm)

0.100" 

Dia. 4 Holes

(2.54mm)

Panel

PC Board

0.531"

(13.5mm)

0.400"

(10.0mm)

0.050" 

Dia. 2 Holes

(1.3mm)

HBW

0.510"

(13.0mm)

1.855"

(47.0mm)

0.040"

(1.05mm)

0.580"

(14.9mm)

Panel

PC Board

0.531"

(13.5mm)

0.400"

(10.0mm)

0.050" 

Dia. 2 Holes

(1.3mm)

Data Sheet: 2118

Data Sheet: 2118

Data Sheet: 2118

FBI

FBM

Fuse Holder Caps (Fit all three shown above)

Specifications

Electrical Ratings: UL — 16A @ 250V; CSA — 12A @ 250V; VDE — 6.3A @ 250V; SEMKO — 10A @ 250V

Insulation resistance — 10 megohm at 500Vdc. Contact resistance — less than 0.005 ohms 
@ 200mV. Dielectric strength — over 200V/mil.

Molded Material: High dielectric molded phenolic with a UL 94V0 flammability rating.

Fuse Carrier & Knob: Spring-loaded, bayonet-type. Tin plated brass. Screwdriver slotted.

Mounting: “Kicked” terminals (all models) and stabilizer pins on HBV & HBW models for increased stability.

Temperature Rating (RTI): Body: 150ºC, Knob: 130ºC

Agency Information: CE, UL Recognized — Guide IZLT2, File EI4853;

CSA Certified — Class 6225-01, File 47235
VDE — 4009241 (HBV, HBW)
SEMKO — 800444

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

95

Electronic

Fuses

PC Board Fuseclips for 5mm Diameter Fuses

0.031"

(0.79mm)

0.217"

(5.5mm)

0.012"

(0.3mm)

0.177"

(4.5mm)

0.319"

(8.1mm)

BUSS

0.61"

(15.5mm)

0.929"

(23.6mm)

BUSS

BUSS

0.50"

(12.7mm)

0.50"

(12.7mm)

0.50"

(12.7mm)

0.157"

(3.99mm)

2.54mm

1.46mm

2.29mm

4.32mm

8.73mm

3.91mm

2.85mm

6.26mm

6.22mm

2.54mm

2.54mm

0.180"

(4.57mm)

0.230"

(5.84mm)

HTC-210M

PCB Mounted Fuseclip with End Stops

Data Sheet: 2110

HTC-15M, HTC-140M

PCB Mounted Fuse Holder & Snap-On Cover

Voltage Rating: 250V, 6.3A, 1.6W

HTC-15M (fuse holder), HTC-140M (natural cover),
HTC-150M* (transparent cover)

Agency Information: 

See Specifications table notes 1, 3

on bottom of page 65

*Available in bulk only. Use this format: BK/HTC-150M

Data Sheet: 2110

HTC-200M

PCB Mounted Fuseclip

Construction: Tin-plated bronze

Tape and Fan Fold packed

Ammo Pack (AP/HTC-200M) 1000 pieces per box

Data Sheet: 2110

1A3399 Series

PCB Fuseclips with End Stops & Straight Leads

Catalog Numbers

Clip Material*

Finish

1A3399-01

Beryllium copper*

Silver

1A3399-04-R

Beryllium copper*

Bright tin

1A3399-10-R

Spring bronze

Bright tin

*Beryllium copper recommended for amps higher than 15 amps.

Data Sheet: 2131

1A5601 Series

PCB Fuseclips (0-7A)

Catalog Number

Clip Material

Finish

1A5601

Cartridge brass

Bright tin

Data Sheet: 2131

1A5602 Series

PCB Fuseclips (0-7A)

Catalog Number

Clip Material

Finish

1A5602

Cartridge brass

Bright tin

Data Sheet: 2131

1A5018 Series

PCB High Profile Fuseclips with End Stops & Straight Leads

Catalog Numbers

Clip Material*

Finish

1A5018-7

Spring bronze

Silver

1A5018-10-R

Spring bronze

Bright tin

*Beryllium copper recommended for amps higher than 15 amps.

Data Sheet: 2131

0.115"

(2.9mm)

0.062"

(1.6mm)

0.254"

(6.5mm)

0.237"

(6.0mm)

0.125"

(3.2mm)

0.225"

(5.7mm)

0.125"

(3.2mm)

0.060"

(1.5mm)

0.188"

(4.8mm)

0.030"

(1.6mm)

0.440"

(11.2mm)

0.140"

(3.7mm)

0.047"

(1.2mm)

0.180"

(4.6mm)

0.250"

(6.35mm)

0.060"

(1.5mm)

0.246"

(6.3mm)

0.344" + 0.015"

(8.73mm + 0.38mm)

0.266"

(6.75mm)

0.344" + 0.015"

(8.73mm + 0.38mm)

0.141" + 0.015"

(3.58mm + 0.38mm)

0.022" + 0.002"

(0.56mm + 0.05mm)

0.032"  

0.002"

(0.81mm  

0.05mm)

+

+

0.216"

(5.48mm)

LEGS TO FIT
IN 0.052" (1.3mm) DIA.
HOLES ON CENTER

0.219"

(5.57mm)

0.047"

(1.19mm)

0.093"

(2.36mm)

0.500" 

(12.70mm)

0.250"

(6.35mm)

0.140"

(3.56mm)

HTC-140M 

Cover

1.047

"

(26.6mm)

0.345

"

(9.0mm)

0.571

"

(14.5mm)

0.866

"

(22.0mm)

0.217

"

(5.5mm)

0.177

"

(4.5mm)

0.890

"

(22.60mm)

Mounting Holes

0.059

+  

0.002"

 Dia. (Typ.)

        

 

_

    

(1.50 

.05mm)

           

 

_

  

  

0.531

"

(13.5mm)

Electronic — PCB & Small Dimension Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

96

Electronic — PCB & Small Dimension Fuses

PC Board Fuseclips for 

1

4

˝ Diameter Fuses

0.245"

(6.2mm)

0.280"

(7.1mm)

(7.1mm)

0.410"

(10.4mm)

0.140"

(3.6mm)

0.060"

(1.5mm)

0.320"

(8.13mm)

(2.6mm)

0.250"

(6.35mm)

0.280"

(7.1mm)

0.155"

(3.94mm)

0.102" Dia.

(2.6mm)

0.245"

(6.2mm)

0.280"

(7.1mm)

0.280"

(7.1mm)

0.410"

(10.4mm)

0.140"

(3.6mm)

0.060"

(1.5mm)

0.320"

(8.13mm)

0.102" Dia.

(2.6mm)

0.255"

(6.5mm)

0.280"

(7.1mm)

0.155"

(3.94mm)

0.102" Dia.

(2.6mm)

0.255"

(6.5mm)

0.410"

(10.4mm)

0.060"

(1.5mm)

0.150"

(3.81mm)

0.245"

(6.2mm)

0.228"

(5.79mm)

0.323"

(8.20mm)

0.280"

(7.11mm)

0.102"

(2.6mm)

0.155"

(3.94mm)

0.320"

(8.13mm)

CL

[6.35]

0.250”

[6.91]

0.272”

[8.13]

0.320”

[2.03]

0.080”

[10.16±0.25]

0.400”±.010

0.155”±.010

[3.94±0.25]

0.290”±.010

[7.37±0.25]

0.363”±.003

[9.22±0.08]

[4.75]

0.187”

0.312”

[7.92]

Ø 

0.130”±.003

[3.3mm±0.08]

0.312"

(7.9mm)

0.132"

(3.4mm)

0.187"

(4.8mm)

0.250"

(6.5mm)

0.420"

(10.67mm)

0.080"

(2.03mm)

0.285"

(7.24mm)

0.155"

(3.9mm)

0.290"

(7.4mm)

0.360"

(9.14mm)

1A3398 Series

PCB Fuseclips without End Stops with Straight Leads

Catalog Numbers

Clip Material

Finish

1A3398-07-R

Cartridge brass

Bright tin

Data Sheet: 2131

1A1907 Series

PCB Fuseclips with End Stops & Straight Leads

Catalog Numbers

Clip Material*

Finish

1A1907-02

Cartridge brass

None/bright dipped

1A1907-03-R

High Performance Copper*

Bright tin

1A1907-05

High Performance Copper*

Silver

1A1907-06-R

Cartridge brass

Bright tin

*High Performance Copper recommended for amps higher than 15A.

Data Sheet: 2131

1A1120 Series

PCB Fuseclips without End Stops or Angled In Leads

Catalog Numbers

Clip Material*

Finish

1A1120-02

Cartridge brass

None/bright dipped

1A1120-05

High Performance Copper*

Silver

1A1120-06-R

High Performance Copper*

Bright tin

1A1120-09-R

Cartridge brass

Bright tin

*High Performance Copper recommended for amps higher than 15A.

Data Sheet: 2131

1A1119 Series

Fuseclips with End Stops & Angled In Leads

Catalog Numbers

Clip Material*

Finish

1A1119-04-R

High Performance Copper*

Bright tin

1A1119-05

High Performance Copper*

Silver

1A1119-10-R

Cartridge brass

Bright tin

*High Performance Copper recommended for amps higher than 15A.

Data Sheet: 2131

1A4534 Series

PCB Fuseclips with End Stops & Angled Out Leads

Catalog Numbers

Clip Material*

Finish

1A4534-01-R

High Performance Copper*

Bright tin

1A4534-06-R

Cartridge brass

Bright tin

*High Performance Copper recommended for amps higher than 15A.

Data Sheet: 2131

1A4533 Series

PCB Fuseclips without End Stops or Angled Out Leads

Catalog Numbers

Clip Material*

Finish

1A4533-01-R

High Performance Copper*

Bright tin

1A4533-06-R

Cartridge brass

Bright tin

*High Performance Copper recommended for amps higher than 15A.

Data Sheet: 2131

0.255"

(6.5mm)

0.410"

(10.4mm)

0.060"

(1.5mm)

0.150"

(3.81mm)

0.245"

(6.2mm)

0.228"

(5.79mm)

0.323"

(8.20mm)

0.280"

(7.11mm)

0.102"

(2.6mm)

0.155"

(3.94mm)

0.320"

(8.13mm)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

97

Electronic

Fuses

PC Board Fuseclips for 

1

4

˝ Diameter Fuses

5681 & 5682 Series

PCB Fuseclips with Mounting Holes For 

1

4

˝ Diameter Fuses

B

C

D

E

Figure 1 

Dimensions (Inches)

Catalog

End

Clip

(To

C

D

E

Hole

Number

Stop

Mat.**

Finish

End Stop) (Contact)

(Height)

(Width)

Dia.

Ref.

5681-01

BeCu

Silver

5681-08

No

Spg. Br.

Nickel

0.265

0.41

0.32

0.132 Fig. 2

5681-15-R

Spg. Br.

Bright Tin

5682-01

BeCu

Silver

0.108

5682-02

BeCu

Silver

5682-11-R

Yes

BeCu

Bright Tin

0.131

0.262

0.41

0.32

0.132 Fig. 1

5682-41-R

Spg. Br.

Bright Tin

0.106

5682-44-R

Spg. Br.

Bright Tin

0.132

C

D

E

Figure 2 

Electronic — PCB & Small Dimension Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

98

Electronic — PCB & Small Dimension Fuses

PCB Fuseclips with Mounting Holes For 

13

32

˝ Diameter Fuses 

PC Board Fuseclips for 

9

32

˝, 

13

32

˝ and 

9

16

˝ Diameter Fuses

5591 & 5592 Series

PCB Fuseclips with Mounting Holes For 

9

16

˝ Diameter Fuses

5672 & 5674 Series

PCB Fuseclips with Mounting Holes For 

9

32

˝ Diameter Fuses

5956 & 5960 Series

Dimensions (Inches)

Catalog

End

Clip

(To

C

D

E

Hole

Number

Stop

Mat.**

Finish

End Stop) (Contact)

(Height)

(Width)

Dia.

Ref.

5591-42

Yes

Spg. Br.

Bright Dip*

0.26

0.51

0.89

0.60

0.172

Fig. 1

5591-52-R

Spg. Br.

Bright Tin

5592-01

No

BeCu

Silver

0.252

0.56

0.875

0.60

0.20

Fig. 2

B

C

D

E

Figure 1 

C

D

E

Figure 2 

Dimensions (Inches)

Catalog

End

Clip

(To

C

D

E

Hole

Number

Stop

Mat.**

Finish

End Stop) (Contact)

(Height)

(Width)

Dia.

Ref.

5672-11

No

Spg. Br.

Bright Tin

0.362

0.52

0.38

0.172 Fig. 2

5674-01

BeCu

Silver

5674-10

Yes

BeCu

Bright Tin

0.168

0.356

0.52

0.38

0.172 Fig. 1

5674-41

Spg. Br.

Bright Tin

*

Bright Dip is actually treated bare metal with no plating.

**

Spg. Br. — Spring Bronze; BeCu — Beryllium Copper.

Hole in center of both clip and contact area.

Dimensions (Inches)

Catalog

End

Clip

(To

C

D

E

Hole

Number

Stop

Mat.**

Finish

End Stop) (Contact) (Height)

(Width)

Dia.

Ref.

5956-16

No

Spg. Br.

Bright Tin

0.312

0.71

0.47

0.172 Fig. 2

5960-07

BeCu

Silver

0.168

0.196

5960-09

BeCu

Silver

0.20

0.172

5960-44

Spg. Br.

Nickel

0.20

0.197

5960-51

Yes

Spg. Br.

Bright Dip*

0.168

0.387

0.71

0.47

0.196 Fig. 1

5960-53

Spg. Br.

Bright Dip*

0.20

0.172

5960-61-R

Spg. Br.

Bright Tin

0.168

0.196

5960-62-R

Spg. Br.

Bright Tin

0.168

0.132

5960-63-R

Spg. Br.

Bright Tin

0.20

0.172

5960-64-R

Spr. Br.

Bright Tin

0.20

0.128

Data Sheet: 2132

1A3400 Series***

For 

13

/

32

˝ Diameter Fuses

With End Stops & Straight Leads

0.218"

(5.54mm)

0.710"

(18.03mm)

0.080"

(2.03mm)

0.470"

(11.94mm)

0.142" Dia.

(3.61mm)

0.050"

(1.27mm)

0.437"

(11.1mm)

0.470"

(11.94mm)

0.380"

(9.65mm)

***For RoHS compliant version add “-R” option code suffix to part number.

Specifications

:

Catalog

Clip

Amp

Number

Material

Finish

Rating

1A3400-09

Spring Bronze

Bright Tin

20A Max.

1A3400-10

Beryllium Copper

Silver

30A Max.

1A3400-12

Spring Brass

Bright Tin

15A Max.

1A3400-09 & 1A3400-10 

1A3400-12

Dimensional Data

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

99

Medium V

oltage

Fuses

Section Contents

Page

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100

E-Rated Fuses

For transformers & feeders . . . . . . . . . . . . . . . . . . 101-104

CL-14 & bolt-in . . . . . . . . . . . . . . . . . . . . . . . . . . . .105-107

For potential & small power transformers . . . . . . . . 108-110

PT fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111

R-Rated fuses for motor circuit protection . .112-114

British IEC fuses for motor circuit protection . . . 115

DIN IEC fuses for transformer protection . . . . . . 116

Expuision Fuse Links . . . . . . . . . . . . . . . . . . 117-118

EEI-NEMA Type K & T and Type H & N fuses . . . 119

Fuseclips for medium and high voltage fuses . . .120

Medium Voltage Fuses

Scan this tag to get the

latest product information for 

Medium Voltage Fuses.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

100

Medium Voltage Fuses

Medium Voltage Fuses

Worldwide Circuit Protection Solutions

Bussmann is a world-leading supplier of medium voltage
fuses. Each product is backed by an efficient worldwide 
distribution network with unrivaled service and technical 
support. Bussmann circuit protection solutions comply with
major international standards: ANSI, BS, DIN, IEC and UL.

Fuse Types

Medium voltage fuses generally fit into two categories –
expulsion fuses and current limiting fuses. The definitions per
ANSI C37.40 are:

Expulsion Fuse: “A vented fuse in which the expulsion effect
of the gases produced by internal arcing, either alone or
aided by other mechanisms results in current interruption.”
Expulsion fuses will limit the duration of an overcurrent
event, but they will not limit the magnitude of fault current. 

Current Limiting Fuse: “A fuse unit that, when in its current-
responsive element is melted by a current within the fuse’s
specified current-limiting range, abruptly introduces a high
resistance to reduce current magnitude and duration, 
resulting in subsequent current interruption.” A current 
limiting fuse will reduce the magnitude a fault current as well
as limit the duration of the overcurrent event when operating
in its current limiting range. Bussmann offers a broad range
of current limiting fuses for protection of feeders, 
transformers and motor circuits designed to ANSI, BS, DIN
and IEC standards.

Medium Voltage Current Limiting Fuses

Current limiting fuses are classified into three categories:

1. Full Range – defined by ANSI C37.40 as “a fuse capable
of interrupting all currents from the maximum rated 
interrupting current down to the minimum continuous current
that causes the melting of the fusible element(s), when the
fuse is applied at the maximum ambient temperature 
specified by the manufacturer.” It is able to interrupt any 
current that will melt its element.

2. General Purpose – defined by ANSI C37.40 as “a fuse
capable of interrupting all currents from the maximum rated
interrupting current down to the current that causes melting
of the fusible element(s) in one hour.” Not all currents fall

within this range. It is possible for the fuse to be exposed to
an overcurrent lower than the value given by the one hour
criteria. In that case, a different overcurrent protection device
would be required to interrupt the overcurrent.

3. Back-up – defined by ANSI C37.40 as “a fuse capable of
interrupting all currents from the maximum interrupting rating
current down to the minimum interrupting current.” 
The minimum interrupting current is the lowest current that
the fuse will be able to clear properly. This creates a need to
place a low current interrupting device, such as motor 
overloads, in series with the back-up rated fuse.

E- and R-Rated Fuses

In North America, current limiting fuses typically fall into the
category of E-Rated fuses and R-Rated fuses. Bussmann
also offers a wide range of current limiting fuses designed to
BS, DIN and IEC standards.

E-Rated fuses are used to protect feeder circuits, power
transformers and potential transformers. E-Rated fuses have
defined current response times specified by ANSI C37.46. 
E-Rated fuses 100A and below must melt in 300sec at an
rms current within the range of 200% to 240% of the 
continuous current rating. E-Rated fuses above 100A must
melt in 600sec at an rms current within the range of 240% to
264% of the continuous current rating of the fuse.
Bussmann offers a wide variety of full range and general 
purpose E-Rated fuses from 2.4kV up to 38kV.

R-Rated fuses are back-up fuses that provide short-circuit
protection for motor circuits. They are applied with MV motor
starters which provide the overload protection for the circuit.
R-Rated fuses also have defined current response times
specified by ANSI C37.46. R-Rated fuses will melt in a range
of 15 – 35sec at a current equal to 100 times the “R” rating.
Bussmann offers 2.4kV, 5.08kV, 7.2kV and 8.3kV R-Rated
fuses for motor circuit protection.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

101

Medium V

oltage

Fuses

E-Rated Fuses for Transformers and Feeders

MV055

Specifications

Description:

E-rated

medium, voltage 
current-limiting fuses for 
transformer and feeder
protection.

Dimensions:

See Catalog Numbers table.

Construction:

Silver ribbon element surrounded by silica

filler housed in a fiberglass tube and plated endcaps. An
epoxy paint protects the fuse tube from the surrounding 
environment.

Ratings:

Volts: — 5.5kV (10-450A)

Amps: — 5-450A (5.5kV)

IR: — 50kA Sym. Max

Agency Information:

Meets E requirements per ANSI

C37.46, Meets full range requirements per ANSI C37.40.

Features and Benefits

• MV055 Standard clip center distance of 12 inches with 2

and 3 inch barrel diameters for retrofitting in existing 
hardware

• Open fuse indicator for ease in troubleshooting
• Full range rating with 50KA Interrupting Rating
• Double pulsed at 90% of minimum I

2

t to establish 

manufacturing reliability

MV055 Typical Applications

• 5.0kV Transformer Primary Protection
• 5.0kV Feeder Circuit Protection
• 5.0kV Voltage Switches
• 5.0kV Metal-enclosed Switchgear

Data Sheet: 6700

5.5kV Catalog Numbers

Min

Max

Dimensions (in)*

Catalog

Amp

Melt

Clear

Clip

Numbers

Rating

I

2

t

I

2

t

Length Dia.

Center Barrels

MV055F1CAX10E

10

850

8,000

MV055F1CAX15E

15

2,070

11,000

MV055F1CAX20E

20

2,370

23,000

MV055F1CAX25E

25

4,650

31,000

MV055F1CAX30E

30

9,490

45,000

MV055F1CAX40E

40

9,490

45,000

MV055F1CAX50E

50

13,600

90,000

MV055F1CAX65E

65

30,700

181,000

MV055F1DAX10E

10

850

8,000

15.75

3

12

1

MV055F1DAX15E

15

2,070

12,000

MV055F1DAX20E

20

2,370

23,000

MV055F1DAX25E

25

4,650

31,000

MV055F1DAX30E

30

9,490

45,000

MV055F1DAX40E

40

9,490

45,000

MV055F1DAX50E

50

13,600

90,000

MV055F1DAX65E

65

30,700

181,000

MV055F1DAX80E

80

54,600

270,000

MV055F1DAX100E

100

116,200

580,000

MV055F1DAX125E

125

167,400

600,000

15.75

3

12

1

MV055F1DAX150E

150

218,700

786,000

MV055F1DAX175E

175

227,900

1,100,000

MV055F1DAX200E

200

297,600

1,520,000

MV055F2DAX250E

250

669,600

2,400,000

15.75

3

12

2

MV055F2DAX300E

300

874,800

3,149,000

MV055F2DAX350E

350

911,600

4,376,000

MV055F2DAX400E

400

1,190,400

6,071,000

MV055F2DAX450E

450

1,555,000

9,796,000

1” = 25.4mm

Recommended Fuse Clips - see page 120

15.75

12

1

1

2

2

Dimensions - in

Diagram 1

Diagram 2

Medium Voltage Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

102

Medium Voltage Fuses

E-Rated Fuses for Transformers and Feeders

MV155

Specifications
Description:

E-rated

medium, voltage 
current-limiting fuses for 
transformer and feeder
protection.

Dimensions:

See Catalog Numbers table.

Construction:

Silver ribbon element surrounded by silica

filler housed in a fiberglass tube and plated endcaps. An
epoxy paint protects the fuse tube from the surrounding 
environment.

Ratings:

Volts: — 15.5kV (5-200A)

Amps: — 5-200A (15.5kV)

IR: — 50kA Sym. Max

Agency Information:

Meets E requirements per ANSI

C37.46, Meets full range requirements per ANSI C37.40.

Features and Benefits

• MV155 Standard clip center distance of 15 and 18 inches

with 2 and 3 inch barrel diameters for retrofitting in existing 
hardware

• Open fuse indicator for ease in troubleshooting
• Full range rating with 50kA Interrupting Rating
• Double pulsed at 90% of minimum I

2

t to establish 

manufacturing reliability

MV155 Typical Applications

• 15.0kV Transformer Primary Protection
• 15.0kV Feeder Circuit Protection
• 15.0kV Voltage Switches
• 15.0kV Metal-enclosed Switchgear

15.5kV Catalog Numbers

Min

Max

Dimensions*

Catalog

Amp

Melt

Clear

Clip

Numbers

Rating

I

2

t

I

2

t

Length Dia.

Center Barrels

MV155F1CBX5E

5

180

2,900

18.75

15

1

MV155F1CBX7E

7

850

8,000

MV155F1CBX10E

10

850

8,000

MV155F1CBX15E

15

2,070

12,000

1

MV155F1CBX20E

20

2,370

23,000

MV155F1CBX25E

25

4,650

31,000

MV155F1CBX30E

30

9,490

45,000

MV155F1DBX10E

10

850

8,000

18.75

3

15

1

MV155F1DBX15E

15

2,070

12,000

MV155F1DBX20E

20

2,370

23,000

MV155F1DBX25E

25

4,650

31,000

MV155F1DBX30E

30

9,490

45,000

MV155F1DBX40E

40

9,490

45,000

MV155F1DBX50E

50

13,600

90,000

MV155F1DBX65E

65

30,700

181,000

MV155F1DBX80E

80

54,600

270,000

MV155F1DBX100E

100

116,200

600,000

MV155F2DBX125E

125

123,000

677,000

18.75

3

15

2

MV155F2DBX150E

150

218,700

1,287,000

MV155F2DBX175E

175

314,700

1,689,000

MV155F2DBX200E

200

465,100

2,405,000

MV155F1DCX65E

65

30,700

181,000

21.75

3

18

1

MV155F1DCX80E

80

54,600

270,000

MV155F1DCX100E

100

116,200

600,000

MV155F2DCX125E

125

123,000

677,000

21.75

3

18

2

MV155F2DCX150E

150

218,700

1,287,000

MV155F2DCX175E

175

314,700

1,689,000

MV155F2DCX200E

200

465,100

2,405,000

*1” = 25.4mm.

Data Sheet: 6700

Data Sheet: 6701

18.75

2

15

1

2

2

1

18

21.75

Recommended Fuse Clips - see page 120

Dimensions - in

Diagram 1

Diagram 2

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

103

Medium V

oltage

Fuses

Medium Voltage Fuses

JCX, JCY, JCU, JCZ
and JDZ

Specifications
Description:

Indoor/enclosure 

E-rated medium voltage, current-
limiting fuses for feeders and
power transformers with blown fuse
indication.

Dimensions:

See Catalog

Numbers table.

Construction:

plated ferrules.

Ratings:

Volts: — 2750-8300V - See Catalog Numbers table for

details

Amps: — 

1

2

-750A

IR: — 40-63kA Sym

— 60-100kA ASYM 

— See Catalog Numbers table for details

E-Rated Fuses for Transformer & Feeders

Catalog Numbers

Catalog

Amp

Maximum

Maximum Interrupting Capacity

Dimensions - in (mm)

Numbers

Rating

Design Voltage

Construction

Amps (Asym.)

Amps (Sym.)

Length

Diameter

2400V; E-Rated; Indoor/Enclosure

JCX-1E

1

2750

Single

60,000

40,000

9.19 (233.38)

2 (50.8)

JCX-2E

2

2750

Single

60,000

40,000

9.19 (233.38)

2 (50.8)

JCX-3E

3

2750

Single

60,000

40,000

9.19 (233.38)

2 (50.8)

JCX-5E

5

2750

Single

60,000

40,000

9.19 (233.38)

2 (50.8)

JCX-7E

7

2750

Single

60,000

40,000

9.19 (233.38)

2 (50.8)

JCX-10E

10

2750

Single

60,000

40,000

9.19 (233.38)

2 (50.8)

JCX-15E

15

2750

Single

80,000

50,000

9.5 (241.3)

2.1 (53.34)

JCX-20E

20

2750

Single

80,000

50,000

9.5 (241.3)

2.1 (53.34)

JCX-25E

25

2750

Single

80,000

50,000

9.5 (241.3)

2.1 (53.34)

JCX-30E

30

2750

Single

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-40E

40

2750

Single

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-50E

50

2750

Single

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-65E

65

2750

Single

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-80E

80

2750

Single

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-100E

100

2750

Single

80,000

40,000

10.81 (276.35)

3 (76.2)

JCX-125E

125

2750

Single

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-150E

150

2750

Single

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-200E

200

2750

Single

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-225E

225

2750

Single

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-250E/280X

250/280

2750

Double

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-300E/325X

300/325

2750

Double

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-350X

350

2750

Double

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-400X

400

2750

Double

80,000

50,000

10.81 (276.35)

3 (76.2)

JCX-450X

450

2750

Double

80,000

50,000

10.81 (276.35)

3 (76.2)

5500V; E-Rated; Indoor/Enclosure

JCY-

1

2

E

0.5

5500

Single

60,000

40,000

11.19 (284.18)

2 (50.8)

JCY-1E

1

5500

Single

60,000

40,000

11.19 (284.18)

2 (50.8)

JCY-2E

2

5500

Single

60,000

40,000

11.19 (284.18)

2 (50.8)

JCY-3E

3

5500

Single

60,000

40,000

11.19 (284.18)

2 (50.8)

JCY-5E

5

5500

Single

60,000

40,000

11.19 (284.18)

2 (50.8)

JCY-7E

7

5500

Single

60,000

40,000

11.19 (284.18)

2 (50.8)

JCY-10E

10

5500

Single

60,000

40,000

11.19 (284.18)

2 (50.8)

JCY-15E

15

5500

Single

60,000

40,000

11.19 (284.18)

2 (50.8)

JCY-20E

20

5500

Single

60,000

40,000

11.19 (284.18)

2 (50.8)

JCY-25E

25

5500

Single

60,000

40,000

11.19 (284.18)

2 (50.8)

Contact Bussmann for the latest product information on E-Rated fuses for transformer and feeder protection.

Recommended fuseclips: see page 120 - 1A0065, 9078A67G04, A3354730

Features and Benefits

• Physically dimensioned for retrofitting in existing hardware
• Open fuse indicator for ease in troubleshooting
• Full range ANSI classification

Typical Applications

• Medium Voltage Transformer Primary Protection
• Medium Voltage Feeder Circuit Protection
• Medium Voltage Switches
• Medium Voltage Metal-enclosed Switchgear

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

104

Medium Voltage Fuses

E-Rated Fuses for Transformer & Feeders

Catalog Numbers: E-Rated; Indoor/Enclosure

Catalog

Amp

Maximum

Maximum Interrupting Capacity

Dimensions - in (mm)

Numbers

Rating

Design Voltage

Construction

Amps. (Asym.)

Amps. (Sym.)

Length

Diameter

5500V; E-Rated; Indoor/Enclosure

JCU-10E

10

5500

Single

80,000

50,000

17.81 (452.4)

3 (76.2)

JCU-15E

15

5500

Single

80,000

50,000

12.88 (327.0)

2.1 (53.34)

JCU-20E

20

5500

Single

80,000

50,000

12.88 (327.0)

2.1 (53.34)

JCU-25E

25

5500

Single

80,000

50,000

12.88 (327.0)

2.1 (53.34)

JCU-30E

30

5500

Single

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-40E

40

5500

Single

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-50E

50

5500

Single

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-65E

60

5500

Single

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-80E

80

5500

Single

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-100E

100

5500

Single

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-125E

125

5500

Single

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-150E

150

5500

Single

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-175E

175

5500

Single

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-200E

200

5500

Single

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-250E

250

5500

Single

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-300E

300

5500

Double

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-350E

350

5500

Double

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-400E

400

5500

Double

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-450E

450

5500

Double

100,000

63,000

17.88 (454.15)

3 (76.20)

JCU-600E

600

5500

*

80,000

50,000

28.81 (731.77)

4 (101.60)

JCU-750E

750

5500

*

80,000

50,000

28.81 (731.77)

4 (101.60)

8300V; E-Rated; Indoor/Enclosure

JCZ-15E

15

8300

Single

80,000

50,000

15.51 (393.95)

2.1 (53.34)

JCZ-20E

20

8300

Single

80,000

50,000

15.51 (393.95)

2.1 (53.34)

JCZ-25E

25

8300

Single

80,000

50,000

15.51 (393.95)

2.1 (53.34)

JCZ-30E

30

8300

Single

80,000

50,000

17.88 (454.15)

3 (76.2)

JCZ-40E

40

8300

Single

80,000

50,000

17.88 (454.15)

3 (76.2)

JCZ-50E

50

8300

Single

80,000

50,000

17.88 (454.15)

3 (76.2)

JCZ-65E

65

8300

Single

80,000

50,000

17.88 (454.15)

3 (76.2)

JCZ-80E

80

8300

Single

80,000

50,000

17.88 (454.15)

3 (76.2)

JCZ-100E

100

8300

Single

80,000

50,000

17.88 (454.15)

3 (76.2)

JCZ-125E

125

8300

Single

80,000

50,000

17.88 (454.15)

3 (76.2)

JCZ-150E

150

8300

Single

80,000

50,000

17.88 (454.15)

3 (76.2)

JCZ-200E

200

8300

Double

80,000

50,000

17.88 (454.15)

3 (76.2)

JDZ-20E

20

8300

Single

80,000

50,000

15.88 (403.2)

3 (76.2)

JDZ-25E

25

8300

Single

80,000

50,000

15.88 (403.2)

3 (76.2)

JDZ-30E

30

8300

Single

80,000

50,000

15.88 (403.2)

3 (76.2)

JDZ-40E

40

8300

Single

80,000

50,000

15.88 (403.2)

3 (76.2)

JDZ-50E

50

8300

Single

80,000

50,000

15.88 (403.2)

3 (76.2)

JDZ-65E

65

8300

Single

80,000

50,000

15.88 (403.2)

3 (76.2)

JDZ-80E

80

8300

Double

80,000

50,000

15.88 (403.2)

3 (76.2)

JDZ-100E

100

8300

Double

80,000

50,000

15.88 (403.2)

3 (76.2)

JDZ-125E

125

8300

Double

80,000

50,000

15.88 (403.2)

3 (76.2)

Recommended fuseclips: see page 120 - 1A0065, 9078A67G04, A3354730

General Notes:
1.  All fuses are fitted with a striker pin which can be used for indication or tripping purposes.
2.  The fuses are suitable for use either indoors or outdoors.
3.  These fuses are interchangeable with corresponding fuses produced by most other leading North American manufacturers.
Contact Bussmann for the latest product information on E-Rated fuses for transformer and feeder protection.
*Bolt on mounting

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

105

Medium V

oltage

Fuses

Medium Voltage Fuses

E-Rated Fuses: CL-14 & Bolt-In

Data Sheet: 9002

Catalog Number Cross Reference

Bussmann

Mersen

Mersen

Catalog Numbers

New Catalog #

Old Catalog #

ECL055-10E

A055C1DORO-10E

225-007-937

ECL055-15E

A055C1DORO-15E

225-007-938

ECL055-20E

A055C1DORO-20E

225-007-939

ECL055-25E

A055C1DORO-25E

225-007-940

ECL055-30E

A055C1DORO-30E

225-007-941

ECL055-40E

A055C1DORO-40E

225-007-942

ECL055-50E

A055C1DORO-50E

225-007-943

ECL055-65E

A055C1DORO-65E

225-007-944

ECL055-80E

A055C1DORO-80E

225-007-945

ECL055-100E

A055C1DORO-100E

225-007-946

ECL055-125E

A055C1DORO-125E

225-007-947

ECL055-150E

A055C1DORO-150E

225-007-948

ECL055-200E

A055C1DORO-200E

225-007-949

ECL055-250E

A055C1DORO-250E

225-007-950

ECL055-300E

A055C1DORO-300E

225-007-951

ECL055-400E

A055C1DORO-400E

225-007-952

ECL055-450E

A055C2DORO-450E

225-007-953

ECL055-500E

A055C2DORO-500E

225-007-954

ECL055-600E

A055C2DORO-600E

225-007-955

ECL055-750E

A055B3DORO-750E

A055X750E-4

ECL055-900E

A055B3DORO-900E

A055X900E-4

ECL055

Specifications
Description:

E-rated medium voltage, current-limiting fuses

for transformer and feeder protection.

Construction:

Filament wound, glass epoxy fuse tube, with

silica filler, and silver-plated copper terminals and endcaps
containing a silver element in a double concentric helical
configuration.

Ratings:

Volts: — 5.5kV

Amps: — 10-900A

IR: — 63kA Sym. Max

Agency Information:

Meets E requirements per ANSI

C37.46, Meets General Purpose requirements per ANSI
C37.40.

Features and Benefits

• Clip-lock and bolt-in style available in double and triple 

barrel fuse designs for application flexibility

• The filament wound, glass epoxy fuse tube provides 

moisture protection for the fuse. This makes Cooper
Bussmann medium voltage fuses suitable for both indoor
and outdoor application (outdoor applications require 
installation inside an appropriate enclosure)

• Open fuse indication (indicator travel distance is 16mm)

easily integrates into automation schemes

• 50/60Hz operating frequency make these fuses applicable

world-wide

Typical Applications

• 5.0kV Transformer Primary Protection
• 5.0kV Feeder Circuit Protection
• 5.0kV Voltage Switches
• 5.0kV Metal-enclosed Switchgear

Catalog Numbers

Catalog

Amp

IR

# of

Numbers

Rating

Voltage

Max Sym.

Barrels

Style

ECL055-10E

10

5.5kV

63kA

1

Clip-Lock

ECL055-15E

15

ECL055-20E

20

ECL055-25E

25

ECL055-30E

30

ECL055-40E

40

ECL055-50E

50

ECL055-65E

65

ECL055-80E

80

ECL055-100E

100

ECL055-125E

125

ECL055-150E

150

ECL055-200E

200

ECL055-250E

250

ECL055-300E

300

2

ECL055-400E

400

ECL055-450E

450

ECL055-500E

500

ECL055-600E

600

ECL055-750E

750

3

Bolt-In

ECL055-900E

900

1

Clip-Lock

Clip-Lock

Bolt-In

2

3

63kA

Catalog Number Construction (Example)

Catalog Number

Voltage Rating

Amp Rating

ECL

055

500E

055 = 5.5 kV

Dimensions - in

Single Barrel

Double Barrel

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

106

Medium Voltage Fuses

E-Rated Fuses: CL-14 & Bolt-In

ECL083

Specifications
Description:

E-rated medium voltage, current-limiting fuses

for transformer and feeder protection.

Construction:

Filament wound, glass epoxy fuse tube, with

silica filler, and silver-plated copper terminals and endcaps
containing a silver element in a double concentric helical
configuration.

Ratings:

Volts: — 8.3kV

Amps: — 65-350A

IR: — 50kA

Agency Information:

Meets E requirements per ANSI

C37.46, Meets General Purpose requirements per ANSI
C37.40.

Features and Benefits

• Clip-lock and bolt-in style available in double and triple 

barrel fuse designs for application flexibility

• The filament wound, glass epoxy fuse tube provides 

moisture protection for the fuse. This makes Cooper
Bussmann medium voltage fuses suitable for both indoor
and outdoor application (outdoor applications require 
installation inside an appropriate enclosure)

• Open fuse indication (indicator travel distance is 16mm)

easily integrates into automation schemes

• 50/60Hz operating frequency make these fuses applicable

world-wide

Typical Applications

• 8.0kV Transformer Primary Protection
• 8.0kV Feeder Circuit Protection
• 8.0kV Voltage Switches
• 8.0kV Metal-enclosed Switchgear

Data Sheet: 9007

Catalog Number Cross Reference

Bussmann

Mersen

Mersen

Catalog Numbers

New Catalog #

Old Catalog #

ECL083-65E

N/A

N/A

ECL083-80E

N/A

N/A

ECL083-100E

N/A

N/A

ECL083-125E

N/A

N/A

ECL083-150E

N/A

N/A

ECL083-175E

N/A

N/A

ECL083-200E

N/A

N/A

ECL083-250E

N/A

N/A

ECL083-300E

N/A

N/A

ECL083-350E

N/A

N/A

Catalog Number Construction (Example)

Catalog Number

Voltage Rating

Amp Rating

ECL

083

300E

083 = 8.3 kV

Electrical Characteristics

IR Max

# of 

Figure

Part Number

Amps

Volts

Sym.

Barrels

#

Style

ECL083-65E

65

8.3kV

50kA

1

1

Clip-Lock

ECL083-80E

80

8.3kV

50kA

1

1

Clip-Lock

ECL083-100E

100

8.3kV

50kA

1

1

Clip-Lock

ECL083-125E

125

8.3kV

50kA

1

1

Clip-Lock

ECL083-150E

150

8.3kV

50kA

1

1

Clip-Lock

ECL083-175E

175

8.3kV

50kA

1

1

Clip-Lock

ECL083-200E

200

8.3kV

50kA

2

2

Clip-Lock

ECL083-250E

250

8.3kV

50kA

2

2

Clip-Lock

ECL083-300E

300

8.3kV

50kA

2

2

Clip-Lock

ECL083-350E

350

8.3kV

50kA

2

2

Clip-Lock

Dimensions - in

Single Barrel

Double Barrel

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

107

Medium V

oltage

Fuses

Medium Voltage Fuses

E-Rated Fuses: CL-14

Catalog Number Cross Reference

Bussmann

Mersen

Mersen

Catalog Numbers

New Catalog #

Old Catalog #

ECL155-10E

A155C1DORO-10E

225-007-967

ECL155-15E

A155C1DORO-15E

225-007-968

ECL155-20E

A155C1DORO-20E

225-007-969

ECL155-25E

A155C1DORO-25E

225-007-970

ECL155-30E

A155C1DORO-30E

225-007-971

ECL155-40E

A155C1DORO-40E

225-007-972

ECL155-50E

A155C1DORO-50E

225-007-973

ECL155-65E

A155C1DORO-65E

225-007-974

ECL155-80E

A155C1DORO-80E

225-007-975

ECL155-100E

A155C1DORO-100E

225-007-976

ECL155-125E

A155C2DORO-125E

225-007-977

ECL155-150E

A155C3DORO-150E

225-007-978

ECL155-200E

A155C3DORO-200E

225-007-979

ECL155-250E

A155C3DORO-250E

225-007-980

ECL155-300E

A155C3DORO-300E

225-007-981

Data Sheet: 9004

Catalog Numbers

Catalog

Amp

IR Voltage

# of

Numbers

Rating

Voltage

Max Sym.

Barrels

Style

ECL155-10E

10

15.5kV

63KA

1

Clip-Lock

ECL155-15E

15

ECL155-20E

20

ECL155-25E

25

ECL155-30E

30

ECL155-40E

40

ECL155-50E

50

ECL155-65E

65

ECL155-80E

80

ECL155-100E

100

ECL155-125E

125

ECL155-150E

150

2

ECL155-200E

200

ECL155-250E

250

50kA

ECL155-300E

300

Catalog Number Construction (Example)

Catalog Number

Voltage Rating

Amp Rating

ECL

155

300E

155 = 15.5 kV

ECL155

Specifications
Description:

E-rated medium voltage, current-limiting fuses

for transformer and feeder protection.

Construction:

Filament wound, glass epoxy fuse tube, with

silica filler, and silver-plated copper terminals and endcaps
containing a silver element in a double concentric helical 
configuration.

Ratings:

Volts: — 15.5kV

Amps: — 10-300A

IR: — 63kA Sym. (10-200A)

— 50kA Sym. (250-300A)

Agency Information:

Meets E requirements per ANSI

C37.46, Meets General Purpose requirements per ANSI
C37.40.

Features and Benefits

• Clip-lock double barrel fuse design assures positive 

installation

• The filament wound, glass epoxy fuse tube provides 

moisture protection for the fuse. This makes Cooper
Bussmann medium voltage fuses suitable for both indoor
and outdoor application (outdoor applications require 
installation inside an appropriate enclosure)

• Open fuse indication (indicator travel distance is 16mm) 

easily integrates into automation schemes

• 50/60Hz operating frequency make these fuses applicable

world-wide

Typical Applications

• 15.0kV Transformer Primary Protection
• 15.0kV Feeder Circuit Protection
• 15.0kV Voltage Switches
• 15.0kV Metal-enclosed Switchgear

15.5kV

63kA

1

Clip-Lock

2

50kA

Dimensions - in

Single Barrel

Double Barrel

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

108

Medium Voltage Fuses

E-Rated Fuses for Potential & Small Power Transformers

AB, AD, AM
and CAV

Specifications
Description:

Indicating and non-indicating E-Rated medium

voltage, current-limiting fuses for potential and small power
transformers.

Dimensions:

See Catalog Numbers table.

Dimension Illustration on the following page

Ratings:

Volts: — 5.5-38kV

Amps: — 0.5-15A

IR: — 40kA-80kA Sym.

— See Catalog Numbers table for details

Features and Benefits

• Sized for retrofitting in existing hardware
• Space saving size

Typical Applications

• Primary protection of  medium voltage potential 

transformers

• Primary protection of small medium voltage service 

transformers

• Primary protection of small medium voltage control 

transformers

3.6kV; E-Rated PT Fuse; Non-indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

3.6CAV2

2

3.6kV

50kA

8.66 (220)

1.63 (41.3)

7.46 (189.48)

1A0835

3.6ABWNA3.15

3.15

3.6kV

50kA

5.6 (142.2)

1 (25.4)

4.42 (112.2)

A3354705

3.6ABWNA6.3

3.15

3.6kV

50kA

5.6 (142.2)

1 (25.4)

4.42 (112.2)

A3354705

3.6ABCNA3.15

3.15

3.6kV

50kA

7.69 (195.3)

1 (25.4)

6.51 (165.3)

A3354705

3.6ABCNA6.3

6.3

3.6kV

50kA

7.69 (195.3)

1 (25.4)

6.51 (165.3)

A3354705

3.6ABCNA10

10

3.6kV

50kA

7.69 (195.3)

1 (25.4)

6.51 (165.3)

A3354705

7.2kV; E-Rated PT Fuse; Non-indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

7.2CAV2

2

7.2kV

63kA

8.66 (220)

1.63 (41.3)

7.46 (189.48)

1A0835

7.2CAV4

4

7.2kV

63kA

8.66 (220)

1.63 (41.3)

7.46 (189.48)

1A0835

7.2CAV6

6

7.2kV

63kA

8.66 (220)

1.63 (41.3)

7.46 (189.48)

1A0835

7.2CAV10

10

7.2kV

63kA

8.66 (220)

1.63 (41.3)

7.46 (189.48)

1A0835

7.2ABWNA3.15

3.15

7.2kV

45kA

5.6 (142.2)

1 (25.4)

4.42 (112.2)

A3354705

7.2ABWNA6.3

6.3

7.2kV

45kA

5.6 (142.2)

1 (25.4)

4.42 (112.2)

A3354705

7.2ABCNA3.15

3.15

7.2kV

45kA

7.69 (195.3)

1 (25.4)

6.51 (165.3)

A3354705

7.2ABCNA6.3

6.3

7.2kV

45kA

7.69 (195.3)

1 (25.4)

6.51 (165.3)

A3354705

7.2AMWNA0.5E

0.5

7.2kV

50kA

5.6 (142.2)

0.81  (20.6)

4.79 (121.6)

1A1837

7.2AMWNA1.0E

1

7.2kV

50kA

5.6 (142.2)

0.81  (20.6)

4.79 (121.6)

1A1837

7.2AMWNA2.0E

2

7.2kV

50kA

5.6 (142.2)

0.81  (20.6)

4.79 (121.6)

1A1837

7.2AMWNA3.0E

3

7.2kV

50kA

5.6 (142.2)

0.81  (20.6)

4.79 (121.6)

1A1837

7.2AMWNA4.0E

4

7.2kV

50kA

5.6 (142.2)

0.81  (20.6)

4.79 (121.6)

1A1837

7.2AMWNA5.0E

5

7.2kV

50kA

5.6 (142.2)

0.81  (20.6)

4.79 (121.6)

1A1837

5.5kV; E-Rated PT Fuse; Indicating & Non-indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

5.5CAVH0.5E

0.5

5.5kV

63kA

7.375 (187.3)

1.63 (41.3)

6.18 (156.84)

1A0835

5.5CAVH1E

1

5.5kV

63kA

7.375 (187.3)

1.63 (41.3)

6.18 (156.84)

1A0835

5.5CAVH2E

2

5.5kV

63kA

7.375 (187.3)

1.63 (41.3)

6.18 (156.84)

1A0835

5.5CAV15E

15

5.5kV

63kA

7.375 (187.3)

1.63 (41.3)

6.18 (156.84)

1A0835

5.5ABWNA0.5E

0.5

5.5kV

50kA

5.6 (142.2)

1 (25.4)

4.42 (112.2)

A3354705

5.5ABWNA1E

1

5.5kV

50kA

5.6 (142.2)

1 (25.4)

4.42 (112.2)

A3354705

5.5ABWNA2E

2

5.5kV

50kA

5.6 (142.2)

1 (25.4)

4.42 (112.2)

A3354705

5.5ABWNA3E

3

5.5kV

50kA

5.6 (142.2)

1 (25.4)

4.42 (112.2)

A3354705

5.5ABWNA5E

5

5.5kV

50kA

5.6 (142.2)

1 (25.4)

4.42 (112.2)

A3354705

5.5AMWNA0.5E

0.5

5.5kV

50kA

5.6 (142.2)

0.81  (20.6)

4.79 (121.6)

1A1837

5.5AMWNA1.0E

1

5.5kV

50kA

5.6 (142.2)

0.81  (20.6)

4.79 (121.6)

1A1837

5.5AMWNA2.0E

2

5.5kV

50kA

5.6 (142.2)

0.81  (20.6)

4.79 (121.6)

1A1837

5.5AMWNA3.0E

3

5.5kV

50kA

5.6 (142.2)

0.81  (20.6)

4.79 (121.6)

1A1837

5.5AMWNA4.0E

4

5.5kV

50kA

5.6 (142.2)

0.81  (20.6)

4.79 (121.6)

1A1837

5.5AMWNA5.0E

5

5.5kV

50kA

5.6 (142.2)

0.81  (20.6)

4.79 (121.6)

1A1837

Type CAVH are fitted with a striker pin for indication

Catalog Numbers: E-Rated PT Fuses, Indicating & Non-Indicating

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

109

Medium V

oltage

Fuses

Medium Voltage Fuses

12kV; E-Rated PT Fuse; Non-indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

12CAV2

2

12kV

40kA

8.66 (220)

1.63 (41.3)

7.46 (189.48)

1A0835

12ABCNA3.15

3.15

12kV

45kA

7.69 (195.3)

1 (25.4)

6.51 (165.3)

A3354705

17.5kV; E-Rated PT Fuse; Non-indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

17.5CAV2

2

17.5kV

40kA

8.66 (220)

1.63 (41.3)

7.46 (189.48)

1A0835

17.5CAV4

4

17.5kV

40kA

8.66 (220)

1.63 (41.3)

7.46 (189.48)

1A0835

17.5CAV6

6

17.5kV

40kA

8.66 (220)

1.63 (41.3)

7.46 (189.48)

1A0835

17.5CAV10

10

17.5kV

40kA

8.66 (220)

1.63 (41.3)

7.46 (189.48)

1A0835

17.5ABGNA3.15

3.15

17.5kV

35kA

14.13 (358.9)

1 (25.4)

12.95 (328.9)

A3354705

24kV; E-Rated PT Fuse; Non-indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

24CAV2

2

24kV

40kA

13.39 (340.1)

1.63 (41.3)

12.19 (309.62)

1A0835

24CAV3

3

24kV

40kA

13.39 (340.1)

1.63 (41.3)

12.19 (309.62)

1A0835

24CAV4

4

24kV

40kA

13.39 (340.1)

1.63 (41.3)

12.19 (309.62)

1A0835

24ABGNA3.15

3.15

24kV

25kA

14.13 (358.9)

1 (25.4)

12.95 (328.9)

A3354705

36kV; E-Rated PT Fuse; Non-indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

36CAV2

2

36kV

40kA

17.32 (439.9)

1.63 (41.3)

16.12 (409.44)

1A0835

36CAV4

4

36kV

40kA

17.32 (439.9)

1.63 (41.3)

16.12 (409.44)

1A0835

36ABGNA3.15

3.15

36kV

31.5kA

14.13 (358.9)

1 (25.4)

12.95 (328.9)

A3354705

38kV; E-Rated PT Fuse; Indicating & Non-indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

38CAVH0.5E

0.5

38kV

40kA

17.32 (439.9)

1.63 (41.3)

16.12 (409.44)

1A0835

38CAVH1E

1

38kV

40kA

17.32 (439.9)

1.63 (41.3)

16.12 (409.44)

1A0835

38CAVH2E

2

38kV

40kA

17.32 (439.9)

1.63 (41.3)

16.12 (409.44)

1A0835

38CAV4E

4

38kV

40kA

17.32 (439.9)

1.63 (41.3)

16.12 (409.44)

1A0835

15.5kV; E-Rated PT Fuse; Indicating & Non-indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

15.5CAV(H)0.5E

0.5

15.5kV

80kA

12.87 (326.9

1.63 (41.3)

1.2 (30.5)

1A0835

15.5CAV(H)1E

1

15.5kV

80kA

12.87 (326.9

1.63 (41.3)

1.2 (30.5)

1A0835

15.5CAV(H)2E

2

15.5kV

80kA

12.87 (326.9

1.63 (41.3)

1.2 (30.5)

1A0835

15.5CAV3E

3

15.5kV

80kA

12.87 (326.9

1.63 (41.3)

1.2 (30.5)

1A0835

15.5CAV5E

5

15.5kV

80kA

12.87 (326.9

1.63 (41.3)

1.2 (30.5)

1A0835

15.5CAV7E

7

15.5kV

80kA

12.87 (326.9

1.63 (41.3)

1.2 (30.5)

1A0835

Type CAVH are fitted with a striker pin for indication

E-Rated Fuses for Potential & Small Power Transformers

Catalog Numbers: E-Rated PT Fuses, Indicating & Non-Indicating

Length

Clip Centers

Diameter

Dimension Illustration

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

110

Medium Voltage Fuses

E-Rated, PT Fuses for Potential & Small Power
Transformers

Data Sheet: 6002

JCD, JCW, JCQ, JCI &
JCT

Specifications
Description:

Indicating and non-

indicating E-rated medium voltage,
current-limiting fuses for potential
and small power transformers.

Dimensions:

See Catalog

Numbers table.

Construction:

Plated ferrules.

Ratings:

Volts: — 2.4-15.5kV (See Catalog Numbers table for details)

Amps: — 

1

2

-10A

IR: — 25-80kA Sym

— 40-130kA ASYM 

— See Catalog Numbers table for details

Features and Benefits

• Sized for retrofitting in existing hardware
• Space saving size

Typical Applications

• Primary protection of  medium voltage potential 

transformers

• Primary protection of small medium voltage service 

transformers

• Primary protection of small medium voltage control 

transformers

2.4kV; E-Rated PT Fuse; Non-indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

JCD-1-2E

0.5

2.4kV

63kA

4.49 (114)

0.8 (20)

3.86 (98)

1A1837

JCD-1E

1

2.4kV

40kA

4.49 (114)

0.8 (20)

3.86 (98)

1A1837

JCD-2E

2

2.4kV

40kA

4.49 (114)

0.8 (20)

3.86 (98)

1A1837

JCD-5E

5

2.4kV

25kA

4.49 (114)

0.8 (20)

3.86 (98)

1A1837

2.4/5.5kV; E-Rated PT Fuse; Non-indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

JCW-1/2E

0.5

2.4kV/5.5kV

40kA

7.31 (185)

1.56 (39.7)

5.93 (150.6)

1A0835

JCW-1E

1

2.4kV/5.5kV

40kA

7.31 (185)

1.56 (39.7)

5.93 (150.6)

1A0835

JCW-2E

2

2.4kV/5.5kV

40kA

7.31 (185)

1.56 (39.7)

5.93 (150.6)

1A0835

JCW-3E

3

2.4kV/5.5kV

40kA

7.31 (185)

1.56 (39.7)

5.93 (150.6)

1A0835

JCW-4E

4

2.4kV/5.5kV

40kA

7.31 (185)

1.56 (39.7)

5.93 (150.6)

1A0835

JCW-5E

5

2.4kV/5.5kV

40kA

7.31 (185)

1.56 (39.7)

5.93 (150.6)

1A0835

5.5kV; E-Rated PT Fuse; Indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

JCQ-3E

3

5.5kV

130kA

9.5 (241.3)

1.6 (40.6)

8.12 (206)

1A0835

JCQ-5E

5

5.5kV

130kA

9.5 (241.3)

1.6 (40.6)

8.12 (206)

1A0835

JCQ-10E

10

5.5kV

130kA

9.5 (241.3)

1.6 (40.6)

8.12 (206)

1A0835

8.3kV; E-Rated PT Fuse; Indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

JCI-3E

3

8.3kV

80kA

12.88 (327)

1.6 (40.6)

11.5 (292)

1A0835

JCI-5E

5

8.3kV

80kA

12.88 (327)

1.6 (40.6)

11.5 (292)

1A0835

JCI-10E

10

8.3kV

80kA

12.88 (327)

1.6 (40.6)

11.5 (292)

1A0835

15.5kV; E-Rated PT Fuse; Indicating

Catalog

Amp

Rated

Dimensions

Spare Parts

Number

Rating

Voltage

IR RMS Sym.

Length

Diameter 

Clip Centers

(Clips)

JCT-3E

3

15.5kV

80kA

17.5 (444.5)

1.6 (40.6)

16.12 (409.4)

1A0835

JCT-5E

5

15.5kV

80kA

17.5 (444.5)

1.6 (40.6)

16.12 (409.4)

1A0835

JCT-10E

10

15.5kV

80kA

17.5 (444.5)

1.6 (40.6)

16.12 (409.4)

1A0835

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

111

Medium V

oltage

Fuses

Medium Voltage Fuses

PT Fuses

Data Sheet: 6003

Fuse blocks:

4528, 4529

Voltage Rating:

1000 to 10,000V

Basic Catalog

Fuse Block

Fuse Clip

Numbers

Catalog Number

Catalog Number

HVA, HVR

4528

5960

HVB, HVT

4529

5960

HVJ, HVU

N/A

4180

HVL, HVX

N/A

4180

Use #8 screws on blocks 4528 and 4529.

Test Specifications

Basic Catalog
Numbers

Load / Opening Time

HVA, HVB, HVJ, HVL

110% / 4 Hours (min)
135% / 1 Hour (max)

HVR, HVT, HVU, HVW, HVX

100% / 4 Hours (min)
150% / 1 Hour (max)

HVA, HVB,
HVJ, HVL,
HVR, HVT,
HVU, HVW &
HVX

Specifications
Description:

Medium voltage, non-time delay, fast-acting

fuses.

Dimensions:

See Basic Catalog Numbers table.

Ratings:

Volts: — 1-10kV (See Basic Catalog Numbers table)

Amps: — 

1

16

-10A (See Basic Catalog Numbers table)

Features and Benefits

• Physical size varies with electrical rating of fuse to prevent

over-fusing.

• Space saving size.

Typical Applications

• Medium Voltage Instrument Protection
• Medium Voltage Circuit Protection

Basic
Catalog

Dimensions - in (mm)

Number

kV

Amp Ratings

Maximum S.C.

Diameter

Length

HVA

1

1

16

1

10

1

8

2

10

1

4

3

10

3

8

1

2

,

20kW DC/30kVA AC

0.41 (10.4)

3 (76.1)

3

4

, 1, 1 

1

2

, 2, 3, 4, 6, 10

HVB

2.5

1

2

3

4

, 1, 1 

1

2

, 2, 3

20kW DC/30kVA AC

0.41 (10.4)

4.5 (114.2)

HVJ

5

1

16

1

8

1

4

1

2

3

4

, 1 

1

2

, 2, 4, 6, 10

20kW DC/30kVA AC

0.81 (20.6)

5 (126.9)

HVL

10

1

16

1

8

1

4

1

2

, 1, 1 

1

2

, 2, 3

20kW DC/30kVA AC

0.81 (20.6)

10 (254)

HVR

1

1

2

, 1, 2, 3, 4, 5

kVA-500 AC only

0.41 (10.4)

3 (76.2)

HVW

1.2

1, 2, 3, 4, 5, 8

kVA-12,000 AC only

0.41 (10.4)

2.25 (57.1)

HVT

2.5

1

2

, 1, 2, 3, 5

kVA-1250 AC only

0.41 (10.4)

4.5 (114.2)

HVU

5

1

2

, 1, 2, 3, 4, 5

kVA-2500 AC only

0.81 (20.6)

5 (126.9)

HVX

10

1

2

, 1, 3, 5

kVA-5,000 AC only

0.41 (10.4)

10.0 (253.8)

Catalog Number Build-A-Code

Basic Catalog Number

Amps

_ _ _ _ _ 

_ _ _

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

112

Medium Voltage Fuses

JCG, JCH, JCK, 
JCK-A, JCK-B, JCL,
JCL-A, JCL-B, JCR-A,
& JCR-B

Specifications
Description:

Indoor/enclosure

R-Rated medium voltage,
current-limiting fuses for motor
circuit protection.

Dimensions:

See Dimensions

illustrations.

Ratings:

Volts: — 2.4-7.2kV (See Catalog Numbers table for details)

Amps: — 25-450A (See Catalog Numbers table for details)

IR: — 50kA Sym

— 80kA ASYM

— See Catalog Numbers table for details

R-Rated Fuses for Motor Circuit Protection

0.38"

(9.5mm)

B

INDICATOR
Showing Fuse is Open

INDICATOR
Showing Fuse
is Open

A

C

Dimensions - mm (in)

Figure 1

Figure 2

Figure 3

Data Sheet 6001

Agency Information:

UL Recognized: 2540Vac — JCK,

JCK-A, 5080Vac — JCL, JCL-A, UL Recognized (Guide
#MSSS2, File #E96676).

Features and Benefits

• Physically dimensioned for retrofitting in existing hardware
• Open fuse indicator for ease in troubleshooting
• Available with optional Cutler Hammer

®

hookeye for ease of

insertion and removal

• Classified as back-up fuses for current-limited protection of

medium voltage motor controllers

Typical Applications

• Medium Voltage Motor Controllers

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

113

R-Rated Fuses for Motor Circuit Protection

Catalog Numbers: R-Rated; Indoor/Enclosure

Catalog

Amp

Maximum

Dimensions - in (mm)*

Max Int. Cap.

Amps

Min Int. Cap.

Numbers

Ratings

Design Voltage

A

B

C

Construction

Amps (Asym.)

(Sym.)

Amps (Sym.)

2400V (See Figure 1)

JCK-2R

70

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

165

JCK-3R

100

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

220

JCK-4R

130

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

320

JCK-5R

150

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

410

JCK-6R

170

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

480

JCK-9R

200

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

720

JCK-12R

230

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

970

JCK-18R

390

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

1,430

JCK-24R

450

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

1,880

2400V — With Westinghouse Ampguard Hookeye (See Figure 1)

JCK-A-2R

70

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

165

JCK-A-3R

100

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

220

JCK-A-4R

130

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

320

JCK-A-5R

150

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

410

JCK-A-6R

170

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

480

JCK-A-9R

200

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

720

JCK-A-12R

230

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

970

JCK-A-18R

390

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

1,430

JCK-A-24R

450

2540

11.24 (285.5)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

1,880

2400V — Bolt-On (See Figures 2 & 3)

JCK-B-30

25

2540

14.18 (360.2)

12.81 (325.4)

-

Single

80,000

50,000

90

JCK-B-2R

70

2540

14.18 (360.2)

12.81 (325.4)

-

Single

80,000

50,000

170

JCK-B-3R

100

2540

14.18 (360.2)

12.81 (325.4)

-

Single

80,000

50,000

245

JCK-B-4R

130

2540

14.18 (360.2)

12.81 (325.4)

-

Single

80,000

50,000

340

JCK-B-5R

150

2540

14.18 (360.2)

12.81 (325.4)

-

Single

80,000

50,000

430

JCK-B-6R

170

2540

14.18 (360.2)

12.81 (325.4)

-

Single

80,000

50,000

500

JCK-B-9R

200

2540

14.18 (360.2)

12.81 (325.4)

-

Single

80,000

50,000

1,000

JCK-B-12R

230

2540

14.18 (360.2)

12.81 (325.4)

-

Single

80,000

50,000

1,250

JCK-B-18R

390

2540

14.18 (360.2)

12.81 (325.4)

3.56 (90.4)

Double

80,000

50,000

1,700

JCK-B-24R

450

2540

14.18 (360.2)

12.81 (325.4)

3.56 (90.4)

Double

80,000

50,000

1,210

2400V — Hermetically Sealed, For Use with Ampguard Motor Starters (See Figure 1)

JCH-30

25

2540

10.81 (275.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

90

JCH-2R

70

2540

10.81 (275.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

170

JCH-3R

100

2540

10.81 (275.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

245

JCH-4R

130

2540

10.81 (275.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

340

JCH-5R

150

2540

10.81 (275.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

430

JCH-6R

170

2540

10.81 (275.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

500

JCH-9R

200

2540

10.81 (275.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

1,000

JCH-12R

230

2540

10.81 (275.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

1,250

JCH-18R

390

2540

10.81 (275.6)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

1,700

JCH-24R

450

2540

10.81 (275.6)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

2,100

4800V (See Figure 1)

JCL-2R

70

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

165

JCL-3R

100

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

220

JCL-4R

130

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

320

JCL-5R

150

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

410

JCL-6R

170

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

480

JCL-9R

200

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

720

JCL-12R

230

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

970

JCL-18R

390

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

1,430

JCL-24R

450

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

1,880

• See previous page Figure 2 for single construction and Figure 3  for double construction information.
Recommended fuseclips: see page 120 - 1A0065, A3354730, 9078A67G04.

Data Sheet: 6001

Medium V

oltage

Fuses

Medium Voltage Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

114

Medium Voltage Fuses

R-Rated Fuses for Motor Circuit Protection

Catalog Numbers: R-Rated; Indoor/Enclosure

Catalog

Amp

Maximum

Dimensions - in (mm)

Max Int. Cap.

Amps

Min Int. Cap.

Numbers

Ratings

Design Voltage

A

B

C

Construction

Amps (Asym.

(Sym.)

Amps (Sym.)

4800V — With Westinghouse Ampguard Hookeye (See Figure 1)

JCL-A-2R

70

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

165

JCL-A-3R

100

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

220

JCL-A-4R

130

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

320

JCL-A-5R

150

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

410

JCL-A-6R

170

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

480

JCL-A-9R

200

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

720

JCL-A-12R

230

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

970

JCL-A-18R

390

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

1,430

JCL-A-24R

450

5080

15.76 (400.3)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

1,880

4800V — Bolt-On (See Figures 2 & 3)

JCL-B-30

30

5080

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

95

JCL-B-2R

70

5080

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

180

JCL-B-3R

100

5080

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

270

JCL-B-4R

130

5080

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

350

JCL-B-5R

150

5080

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

450

JCL-B-6R

170

5080

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

540

JCL-B-9R

200

5080

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

700

JCL-B-12R

230

5080

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

1,000

JCL-B-18R

390

5080

19.25 (488.9)

17.88 (454.1)

3.31 (84.1)

Double

80,000

50,000

1,450

JCL-B-24R

450

5080

19.25 (488.9)

17.88 (454.1)

3.31 (84.1)

Double

80,000

50,000

2,000

4800V — Hermetically Sealed, For Use with Ampguard Motor Starters (See Figure 1)

JCG-30

30

5080

15.91 (404.1)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

95

JCG-2R

70

5080

15.91 (404.1)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

180

JCG-3R

100

5080

15.91 (404.1)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

270

JCG-4R

130

5080

15.91 (404.1)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

350

JCG-5R

150

5080

15.91 (404.1)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

450

JCG-6R

170

5080

15.91 (404.1)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

540

JCG-9R

200

5080

15.91 (404.1)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

700

JCG-12R

230

5080

15.91 (404.1)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

1,000

JCG-A-18R

390

5080

15.91 (404.1)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

1,450

JCG-A-24R

450

5080

15.91 (404.1)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

2,000

7200V — With Ampguard Hookeye (See Figure 1)

JCR-A-2R

70

8300

15.85 (402.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

160

JCR-A-3R

100

8300

15.85 (402.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

250

JCR-A-4R

130

8300

15.85 (402.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

325

JCR-A-5R

150

8300

15.85 (402.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

390

JCR-A-6R

170

8300

15.85 (402.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

500

JCR-A-9R

200

7200

15.85 (402.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

750

JCR-A-12R

230

7200

15.85 (402.6)

3.0 (76.2)

3.0 (76.2)

Single

80,000

50,000

1,000

JCR-A-18R

390

7200

15.85 (402.6)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

1,450

JCR-A-24R

450

7200

15.85 (402.6)

3.0 (76.2)

3.0 (76.2)

Double

80,000

50,000

2,500

7200V — Bolt-On (See Figures 2 & 3)

JCR-B-2R

70

8300

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

160

JCR-B-3R

100

8300

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

250

JCR-B-4R

130

8300

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

325

JCR-B-5R

150

8300

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

390

JCR-B-6R

170

8300

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

500

JCR-B-9R

200

7200

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

750

JCR-B-12R

230

7200

19.25 (488.9)

17.88 (454.1)

-

Single

80,000

50,000

1,000

JCR-B-18R

390

7200

19.25 (488.9)

17.88 (454.1)

3.31 (84.1)

Double

80,000

50,000

1,450

JCR-B-24R

450

7200

19.25 (488.9)

17.88 (454.1)

3.31 (84.1)

Double

80,000

50,000

2,500

Recommended fuseclips: see page 120 - 1A0065, A3354730, 9078A67G04.

Data Sheet: 6001

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

115

Medium V

oltage

Fuses

Table of Ratings

Basic Cat.

Breaking

Dimensions - in (mm)

Number

Volts

Capacity

Amp Ratings

Length

Diameter

Dimensional Standard

3.6WJON6

3.6kV

50kA

5, 6.3, 10, 16, 20, 25, 31.5, 40, 50

7.56 (192)

1.4 (35.6)

BS 2692 (TA1) Interchangeable with GEC Type K2 PA

3.6WDOH6

3.6kV

50kA

50, 63, 80, 100, 125

7.56 (192)

2 (50.8)

BS 2692 (TA1) or DIN 43625

3.6WFOH6

3.6kV

50kA

160, 200

7.56 (192)

3 (76.2)

BS 2692 (TA1) or DIN 43625

3.6WDLSJ

3.6kV

50kA

50, 63, 80, 100, 125

11.5 (292.1)

2 (50.8)

DIN 43625

3.6WFLSJ

3.6kV

50kA

160, 200

11.5 (292.1)

3 (76.2)

DIN 43625

3.6WDFHO

3.6kV

50kA

50, 63, 80, 100, 125

10 (254)

2 (51) 

BS 2692 (TA2)

3.6WFFHO

3.6kV

50kA

160, 200

10 (254)

3 (76.2)

BS 2692 (TA2)

3.6WKFHO

3.6kV

50kA

250, 315, 355, 400

10 (254)

3 (76.2)

BS 2692 (TA2)

5.5VFNHA

5.5kV

60kA

2R-6R

15.86 (402.8)

3 (76.2)

ANSI R-Rated

5.5VKNHA

5.5kV

60kA

9R-24R

15.86 (402.8)

3 (76.2)

ANSI R-Rated

7.2WFNHO

7.2kV

40kA

25, 31.5, 40, 50, 63, 80, 100, 125, 160

15.86 (402.8)

3 (76.2)

BS 2692 (TA4)

7.2WKNHO

7.2kV

40kA

200, 224, 250, 315

15.86 (402.8)

3 (76.2)

BS 2692 (TA4)

7.2WFMSJ

7.2kV

63kA

25, 31.5, 40, 50, 63, 80, 125, 160

17.40 (442)

3 (76.2)

DIN 43625

7.2WKMSJ

7.2kV

63kA

200, 224, 250, 315, 355

17.40 (442)

3 (76.2)

DIN 43625

British Standard Dimensioned IEC Fuses for 
Motor Circuit Protection

Catalog Number Build-A-Code

kV

Basic Catalog Number

Amps

_ _ _

_ _ _ _ _

_ _ _

The Bussmann range of motor fuses are designed to meet
the specific requirements necessary for motor protection.
During the starting cycle of direct on-line motors, the fuse
elements will reach a considerably higher temperature than
during normal operation; (this is due to the high amount of
current the motor will draw as it starts, typically, six times its
normal load current value). This results in expansion and
contraction of the fuse elements and could cause premature
operation of the fuse.

Bussmann motor fuses encompass an advanced design to
minimize this effect. This therefore, negates the need to over
specify the fuse rating due to high values of motor starting
current.

Bussmann motor fuses operate extremely quickly under
heavy fault currents, resulting from the time / current 
characteristic. Low power dissipation ensures low 
temperature rise, important in multi-tier starters for example.
Switching (arc), voltages are lower than permitted values,
therefore, 5.5kV fuses are also suitable for 4.8kV and 
2.4kV circuits.

Medium Voltage Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

116

Medium Voltage Fuses

DIN Dimension Fuses

To Spec. DIN 43625

Specifications
Catalog Symbol:

See Basic Catalog Numbers table.

Description:

DIN dimension fuses to Specification DIN

43625 covering current-limiting fuses with performance in
compliance with IEC 60282-1. These are in accordance with
the R10 and, in some cases, the R20 series of preferred
numbers.

Dimensions:

See Catalog Numbers table.

DIN Dimensioned IEC Fuses for Transformer Protection

Volts: — See voltage associated with the Basic Catalog

Numbers in the table.

Amps: — See amp rating associated with the Basic Catalog

Numbers in the table.

IR: — See IR associated with the Basic Catalog Numbers

in the table.

Agency Information:

Comply with DIN dimensional

standard DIN 43625, VDE 0670 part 4, VDE 0670 part 40Z
and with IEC 60282-1 (2005).

Features and Benefits

• DIN dimensioned for retrofitting in existing hardware
• Open fuse indicator for ease in troubleshooting
• Designed for use in IEC equipment

Typical Applications

• Medium Voltage IEC designed equipment

Catalog Number Build-A-Code

kV

Basic Catalog Number

Amps

_ _ _

_ _ _ _ _

_ _ _

kV

Catalog Numbers

Amp Ratings

Dimensions - in (mm) Diameter x Length

IR RMS Sym

3.6ADOSJ(amp)

6.3, 10, 16, 20, 25, 31.5, 40

2.00 x 7.56 (51 x 192)

40kA

3.6WDOSJ(amp)

50, 63, 80, 100, 125

2.00 x 7.56 (51 x 192)

3.6WFOSJ(amp)

160, 200

3.00 x 7.56 (76 x 192

3.6

3.6ADLSJ(amp)

25, 40

2.00 x 11.50 (51 x 292)

50kA

3.6WDLSJ(amp)

50, 63, 80, 100, 125

2.00 x 11.50 (51 x 292)

3.6WFLSJ(amp)

160, 200

3.00 x 11.50 (76 X 292)

3.6WKLSJ(amp)

250, 315, 400

3.00 x 11.50 (76 X 292)

7.2TDLSJ(amp)

6.3, 10, 16, 20, 25, 31.5, 40, 50, 63

2.00 x 11.50 (51 x 292)

7.2

7.2TFLSJ(amp)

80, 100, 125, 160

3.00 x 11.50 (76 x 292)

40kA

7.2WKMSJ(amp)

200, 225, 250, 315, 355

3.00 x 17.41 (76 x 442)

12TDLEJ(amp)

6.3, 10, 16, 20, 25, 31.5, 40, 50, 63

2.00 x 11.50 (51 x 292)

12

12THLEJ(amp)

80, 100

2.52 x 11.50 (64 x 292)

63kA

12TKLEJ(amp)

125

3.00 x 11.50 (76 x 292)

12TXLEJ(amp)*

160, 200

3.50 x 11.50 (88 x 292)

17.5TDLSJ(amp)*

6.3, 10, 16, 20, 25, 31.5, 40

2.00 x 11.50 (51 x 292)

17.5TFLSJ(amp)*

50

3.00 x 11.50 (76 x 292)

35.5kA

17.5

17.5TDMEJ(amp)

6.3, 10, 16, 20, 25, 31.5, 40, 50, 63

2.00 x 17.41 (51 x 442)

17.5THMEJ(amp)

80, 100

2.52 x 17.41 (64 x 442)

50kA

17.5TKMEJ(amp)

125

3.00 x 17.41 (76 x 442)

24TDMEJ(amp)

6.3, 10, 16, 20, 25, 31.5, 40, 50

2.00 x 17.41 (51 x 442)

24

24THMEJ(amp)

63

2.52 x 17.41 (64 x 442)

50kA

24TFMEJ(amp)

80, 100*

1

3.00 x 17.41 (76 x 442)

24TXMEJ(amp)*

125

2

, 160

3.46 x 17.41 (88 x 442)

31.5kA

36TDQSJ(amp)

3.15

3

, 6.3, 10, 16, 20, 25

2.00 x 21.16 (51 x 537)

35.5kA

36

36TFQSJ(amp)

31.5, 40, 50

3.00 x 21.16 (76 x 537)

36TXQEJ(amp)*

63

3.46 x 21.16 (88 x 537)

20kA

Catalog Numbers

For Diameter and Length Dimensions See Table Above

1.77"

45.0mm

Diameter

0.59"

15.0mm

Striker In

Operated Position

Length

1.34"

34.0mm

1.02"

26.0mm

Dimensions - In (mm)

Recommended fuseclips for DIN style fuses – 270303, A3354745 see page 120.
*Not compliant with VDE 0670, part 402.

1

-IR RMS Sym is 63kA

2

-IR RMS Sym is 40kA

3

-IR RMS Sym is 20kA

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

117

Medium V

oltage

Fuses

Medium Voltage Fuses

Expulsion Fuse Links for Use in High Voltage Distribution 
Cut-Outs

Rated

Voltage

(kV)

1st Letter 

Type of Current Characteristics

2nd Letter 

Type of Termination

Rated

Current 

(A)

15

25

46 

72

T

= complies with ANSI C 37-42 requirements for slow  

acting T characteristics

K

= complies with ANSI C 37-42 requirements for fast 

acting K characteristics

XA

= this type of expulsion fuse link has an extra rapid 

characteristic. It is suitable for applications where a 

high degree of system protection is required at the 

expense of discrimination

S

= Solid links rated at 100A are also available in both 

button head and universal versions for fitting into 

expulsion fuse carriers where required. These can be 

ordered in a similar way using the abbreviation S, e.g. 

15SB, etc

B

= a fixed NEMA button head link

U

= a universal link, with double tail and slip off 

NEMA button head

D

= double tailed link without NEMA button 

head

BR

= as pattern B but the button head is  

attached via a 1/4 UNF thread to allow use of  
an extension rod.

See outline drawings  opposite page for 
reference

1, 2, 3, 4, 5,

6, 7.5, 8, 10,

12, 15, 20,
25, 30, 40,
50, 60, 65,

75, 80, 100

Specifications

Description:

Expulsion fuse links

available in a wide range of
options from 15kV to 72kV in
ANSI T&K characteristics.

Ratings:

Volts:  — 15 to 72kV

Amps: — 1 to 100A
Breaking Capacity: depends on voltage but is approximately 8kA

Agency Information:

Type T: complies with ANSI C37-42 
Type K: complies with ANSI C37-42

Features and Benefits

Wide range of options available from 15kV to 72kV in ANSI
T & K characteristics.

•  

Extra rapid option also available.

Packaging: 

Up to and including 50A: 25 in a carton
From 60A to 100A: 10 in a carton
To avoid incorrect replacement the fuse links have colour
coded labels:
Pink label: Type XA
Yellow label: Type K
Green label: Type T

Typical Applications:

Primary side transformer protection 

Feeder protection

Capacitor bank protection

Use of Application

Expulsion fuse links current ratings should be selected on the

basis of maximum expected transient no damage currents

rather than on full load current. In addition, the selection of

higher current ratings will reduce the possibility of supply

interruption due to transient surges such as those due to

lightning strikes.

Links should be handled with a reasonable degree of care

when installing. Excessively rough handling may damage the

element.

It is normal, under certain fault conditions, for arc 

extinguishing material and/or metal particles to be expelled

from the fuse assembly. It is therefore recommended that

reasonable precautions be taken to prevent the installation

being approached by unauthorised persons.

How to order - Parts Referencing System

Thus a typical ordering reference for a 15kV NEMA Type K,

button head 30A fuse link would be 15KB30 expulsion fuse

link.

The fuse link assembly for a given range is standard to all

rated voltages. The exception is that the tail length is varied

to suit the dimensions of expulsion carrier of different ratings.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

118

Medium Voltage Fuses

1-50A

60-100A

Type kV

A

15kV

533 (21”)

25kV

660 (26”)

46kV

787 (31”)

72kV

1016 (40”)

Notes: Type BR is similar to button

head shown, except that the button

head is attached via a 

1

4

UNF thread.

Tails can be cut to any length.

Dimensions - mm (in)

Expulsion Fuse Links for Use in High Voltage Distribution 
Cut-Outs

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

119

Medium V

oltage

Fuses

EEI-NEMA Type K & T and Type H & N

Catalog Numbers

EEI-NEMA and High-Surge Universal Tin Element

Fuses for Cutouts — Rated to 27kV

Non-Removable Button-Head For Standard Open or Enclosed Cutouts

Catalog Numbers
Type H

EEI-NEMA

EEI-NEMA

(High

Type K

Type T

Surge)

(Fast)

(Slow)

Amps

FL11H1

FL11K1

FL11T1

1

FL11H2

FL11K2

FL11T2

2

FL11H3

FL11K3

FL11T3

3

FL11H5

FL11K5

FL11T5

5

FL11K6

FL11T6

6

FL11H8

FL11K8

FL11T8

8

FL11K10

FL11T10

10

FL11K12

FL11T12

12

FL11K15

FL11T15

15

FL11K20

FL11T20

20

FL11K25

FL11T25

25

FL11K30

FL11T30

30

FL11K40

FL11T40

40

FL11K50

FL11T50

50

FL11K65

FL11T65

65

FL11K80

FL11T80

80

FL11K100

FL11T100

100

FL11K140

FL11T140

140

FL11K200

FL11T200

200

Removable Button-Head For Cutouts Requiring Removable-Button Links

Catalog Numbers
EEI-NEMA

EEI-NEMA

Type K

Type T

(Fast)

(Slow)

Amps

FL3K1

FL3T1

1

FL3K2

FL3T2

2

FL3K3

FL3T3

3

FL3K5

FL3T5

5

FL3K6

FL3T6

6

FL3K8

FL3T8

8

FL3K10

FL3T10

10

FL3K12

FL3T12

12

FL3K15

FL3T15

15

FL3K20

FL3T20

20

FL3K25

FL3T25

25

FL3K30

FL3T30

30

FL3K40

FL3T40

40

FL3K50

FL3T50

50

FL3K65

FL3T65

65

FL3K80

FL3T80

80

FL3K100

FL3T100

100

FL3K140

FL3T140

140

FL3K200

FL3T200

200

Adapter-type removable-button links with ferrule adapter to convert to double-leader  

links are available in K and T types. Order by description.

EEI-NEMA Type K Universal Silver-Element Fuses

for Cutouts —  Rated through 27kV

Non-Removable Button-Head For Standard Open or Enclosed Cutouts

Catalog Numbers
EEI-NEMA

Type K

Amps

FL12K8

8

FL12K10

10

FL12K12

12

FL12K15

15

FL12K25

25

FL12K50

50

FL: Type H and
EEI-NEMA Type K
& T Fuses

Specifications
Description:

Medium

voltage fuses: Type H
(high surge), EEI-NEMA
Type K (fast-acting), 
EEI-NEMA Type T 
(slow-acting).

Ratings:

Amps: — 1-200A 

(See Catalog
Numbers tables)

Features and Benefits

• Wide range of EEI-NEMA type fuse links for use in open

fuse cutouts

• Voltage ratings up to 27kV.
• Can be coordinated with other overcurrent protective

devices for sectionalizing to isolate feeder branches.

Typical Applications

• Medium Voltage Fused Cutouts

High-Surge Type H Fuses

High-surge, Type H fuses are manufactured in ratings of 1, 2,
3, 5, and 8A. They have been developed principally for 
primary fusing of small-sized transformers. Type H links are
manufactured in the universal buttonhead design.

Type N Fuses

Type N fuses conform to previous NEMA standards and have
been superseded by Type K and T links. Type N fuses are
manufactured in the universal button design in ratings of 5
through 200A for use in NEMA standard dimensioned cutouts
rated through 27kV.

Medium Voltage Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

120

Medium Voltage Fuses

Fuseclips for Medium & High Voltage Fuses

1A0065

3˝ Diameter Clip

270303

DIN Fuseclip

C

B

A

G

E

F

D

9078A67G04

3˝ Diameter Clip

2 Cup assemblies per package.
Dimensions shown are for reference only.

Recommended Fuseclips for Medium Voltage Fuses

Fuse

Catalog

Diameter - 

Clip Dimensions (in)

Numbers

in (mm)

A

B

C

D

E

F

G

A3354710

2 (50.8)

3.749

1.979

2.009

1.189

4.539

1.509

0.399

A3354730

3 (76)

4.139

2.449

3.009

1.189

5.639

1.509

0.399

A3354745

1.77 (45)

3.50

2.50

1.77

1.19

4.50

1.50

0.38

Fuseclips are for single barrel applications only. Are not sold in pairs.

A

A

0.43"

10.8mm

0.99"

25.0mm

4.06"

103mm

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

121

High Speed

Fuses

High Speed Fuses

Section Contents

Page

General Applications . . . . . . . . . . . . . . . . . . . . . . .122-123

North American fuses & accessories . . . . . . . . . . .124-141

DFJ - High speed Class J fuse  . . . . . . . . . . . . . . . . . . 125

Square Body fuses & accessories  . . . . . . . . . . . . 142-213

BS 88 fuses & accessories . . . . . . . . . . . . . . . . . .214-222

Ferrule fuses & accessories. . . . . . . . . . . . . . . . . .223-243

TM

Scan this tag to get the

latest product information for 

High Speed Fuses.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Power Factor

For other power factor
values, the total clearing
integral can be
calculated as a multiple
of the clearing integrals,
the correction factor K
and the correction factor
X.

Arc Voltage

This curve gives the
peak arc voltage, UL,
which may appear
across the fuse during its
operation as a function
of the applied working
voltage, Eg, (rms) at a
power 
factor of 15%.

Power Losses

Watts loss at rated 
current is given in the
electrical characteristics.
The curve allows the 
calculation of the power
losses at load currents
lower than the rated 
current . The correction
factor, Kp , is given as a
function of the RMS load
current, Ib , in % of the
rated current .

Cut-Off Current

A fuse operation relating to short-circuits only. When a fuse
operates in its current-limiting range, it will clear a short-

circuit in less than 

1

2

cycle. Also, it will limit the instantaneous

peak let-through current to a value substantially less than

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

122

High Speed Fuses

Prospective Current in Amps RMS

Peak Let-Through Current

10

 10

2

2

10

3

10

4

10

5

10

3

10

4

10

5

10

6

A

B

General Applications

Rated Voltage

The AC voltage rating of Bussmann fuses is given in volts
rms. Fuses tested to IEC are tested at 5% above their rated
voltage. British Style BS 88 fuses are tested at 10% above
its rated voltage. UL recognition tests are performed at the
rated voltage.

Rated Current

Rated current is given in amps rms. Bussmann fuses can
continuously carry the rated current.

Melting Characteristic

The melting
characteristic
shows the virtual
melting time in
seconds as a
function of the
prospective current
in amps rms. The
fuses are specially
constructed for
short-circuit
protection against
high level fault
currents. Loading
and operation of
the fuse in the non-
continuous/dashed
section of the melt
curve must be
avoided. The curve
can also be read
as the real melting
time as a function
of the RMS value
of the pre-arc current.

Clearing Integrals

The total clearing I

2

t at

rated voltage and at
power factor of 15% are
given in the electrical
characteristics. For
other voltages, the
clearing I

2

t is found by

multiplying by correction
factor, K, given as a
function of applied
working voltage, Eg,

(rms).

10

4

10

3

10

2

10

1

2

2

4

6

8

2

10

2

2

4

6

8 10

3

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

Prospective Current In Amperes RMS

Vir

tual Pre-Arcing 

Time In Seconds

10

–4

10

–3

10

–2

10

–1

K

1.5

1.0

0.5

0.4

0.3

0.2

100 200 300 400 500 600 660

E

g

1.0

0.9

0.8

0.7

0.1

0.2

0.3

0.4

0.5

     COS 

X

U

L

1.4
1.2

10

3

6

8
7

9

5

4

3

200 300

400

500

600 660

E

g

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

123

High Speed

Fuses

General Applications

that obtainable in the same circuit if that fuse were replaced
with a solid conductor of equal impedance.

A asymmetrical current
B symmetrical current

Parallel Connection

When fuses are connected in parallel it is recommended that
the applied voltage does not exceed 0.9 UN (the rated 

voltage of the fuse). This is due to the fact that the energy
released within the fuses may be unevenly shared between
the parallel connected barrels.

When fuses are connected in parallel, one must take into
account that the current sharing is not necessarily equal. And
it must be checked, that the maximum load current is not
exceeded.

Series Connection

Fuses in series may not equally divide the applied voltage. It
is recommended that series connected fuses should only be
operated at fault currents that yield melting times less than
10 ms and a recovery voltage per fuse of less than or equal
to 0.9 UN (the rated voltage of the fuse).

Mounting Guidance

The recommendations below have to be followed when
mounting a Bussmann fuse with end plate threaded holes.

1. Screw in studs: 5 N•m Max, 3 N•m Min
2. Attachment of the fuse to bussbar by means of nut and  

washer:

Thread

Torque (N•m)*

Configuration

Max

Min

5

16

” – 18, M8

25

20

3

8

” – 16, M10

45

40

3

8

” – 24

45

40

1

2

” – 13, M12

65

50

1

2

” – 20

65

50

*1 N•m = 0.7375 lb-ft

Overloads

The design of Bussmann fuses is such that they can be
operated under rather severe operating conditions imposed
by overloads (any load current in excess of the maximum
permissible load current).

In applications, there will be a maximum overload current,
Imax, which can be imposed on the fuse with a 
corresponding duration and frequency of occurrence.

Time durations fall into two categories:

1. Overloads longer than one second
2. Overloads less than one second termed “impulse” loads.

The following table gives general application guidelines
which, in the expression Imax < (% factor) x It. It is the 

melting current corresponding to the time “t” of the overload
duration as read from the time-current curve of the fuse. The
guidelines in the table below determine the acceptability of
the selected fuses for a given Imax.

Frequency of Occurrence

Overloads (> 1 sec)

Impulse Loads (< 1 sec)

Less than once per month

Imax < 80% x It

Imax < 70% x It

Less than twice per week

Imax < 70% x It

Imax < 60% x It

Several times per day

Imax < 60% x It

When impulse loads are an intrinsic/normal parameter of the
load current either as single pulse or in trains of pulses or
when their level is higher than the melting current at 0.01
seconds (per time-current curve), contact Bussmann for
application assistance.

In addition to the parameters set forth in the preceding table,
the RMS value of the load current as calculated for any 
period of 10 minutes or more should not exceed the 
maximum permissible load current.

Furthermore, it is important that a fuse should not be applied
in the non-continuous/dashed portion of the associated 
time-current curve.

Any time-current combination point which falls in the 
non-continuous/dashed portion of the time-current curve is
beyond the capability of the fuse to operate properly.

DC Operation

Depending upon the short-circuit time constant and the 
magnitude of the prospective short-circuit current, the dc
voltage at which a fuse can be applied may be less than its
ac rating. Long time constants require a lower dc voltage.
Conversely, however, higher available prospective short-
circuit currents result in faster fuse openings and thus permit
a fuse to be operated at a higher DC voltage.

Consult Bussmann for
additional information and
application assistance
when fuses have to 
operate under DC 
conditions.

Load Current Versus

Conductor Cross

Section

Reduction of permissible
load current when the conductor cross section is less than
that given in IEC Publication 269-1 & 4 valid for Bussmann
high speed fuses.

Application Assistance

If you have application problems or need a fuse outside our
standard program, please contact the nearest Bussmann
representative. Phone numbers are shown on the back
cover.

1 . 0

0 . 9

0 . 8

0 . 5

0 . 6

0 . 7

0 . 8

0 . 9

1 . 0

≈ (IEC cross section)

Reduction Factor

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Introduction

North American Contents

Catalog

Amp

Number

Volts

Range

Page

DFJ

600

1-600

125

FWA

130

1000-4000

126-127

FWA

150

70-1000

128-129

FWX

250

35-2500

130-131

FWH

500

35-1600

132-133

KAC

600

1-1000

134

KBC

600

35-800

135

FWP

700

5-1200

136-138

FWJ

1000

35-2000

139-140

Accessories

Fuse Bases

141

North American Fuse Ranges

Amps

Volts

AC

DC

1000-4000

130

X

X

70-1000

150

X

X

35-2500

250

X

X

35-1600

500

X

X

1-1000

600

X —

5-1200

700

X

X

40-600

800

X

35-2000

1000

X

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

124

High Speed Fuses

North American Fuses

General Information

Bussmann offers a complete range of North American blade
and flush-end style fuses and accessories. Their design and
construction were optimized to provide:

•  Low energy let-through (I

2

t)

•  Low watts loss
•  Superior cycling capability
•  Low arc voltage
•  Excellent DC performance

North American style fuses provide an excellent solution for
medium power applications. While there are currently no
published standards for these fuses, the industry has
standardized on mounting centers that accept Bussmann
fuses.

Voltage Rating

All Bussmann North American style fuses are tested at their
rated voltage. Bussmann should be consulted for applications
exceeding those values.

Accessories

External and internal open fuse indication is available for
selected portions of the North American line. Fuse blocks are
available for most applications.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/datasheetsele

125

High Speed

Fuses

High Speed Fuses

Specifications
Description:

High speed, current-limiting fuse. The

Bussmann Drive Fuse will provide maximum protection for
AC and DC drives and controllers and meet NEC

®

branch

circuit protection requirements. The Drive Fuse has the 
lowest I

2

t of any branch circuit fuse to protect power 

semiconductor devices that utilize diodes, GTOs, SCRs and
SSRs.

Dimensions:

See page 21 for Class J dimensions.

Construction:

Melamine tube with silver fuse element.

Ratings:

Volts — 600Vac (or less), 450Vdc (or less)

Amps — 1-600A

IR — 200kA RMS Sym., 100kA DC

Agency Information:

CE, Std. 248-8, Class J, UL Listed,

Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File
53787.

Features and Benefits

• Easily coordinated with existing and new variable speed 

drives and electric controllers.

• Standard Class J dimensions allowing the use of readily

available fuse blocks, holders, and switches.

• Allows the lowest let-thru energy of any branch circuit 

overcurrent protective device.

Typical Applications

• Protection of AC and DC drives
• Equipment using power semiconductor devices

Catalog Numbers (Amps)

DFJ-1

DFJ-15

DFJ-70

DFJ-225

DFJ-2

DFJ-20

DFJ-80

DFJ-250

DFJ-3

DFJ-25

DFJ-90

DFJ-300

DFJ-4

DFJ-30

DFJ-100

DFJ-350

DFJ-5

DFJ-35

DFJ-110

DFJ-400

DFJ-6

DFJ-40

DFJ-125

DFJ-450

DFJ-8

DFJ-45

DFJ-150

DFJ-500

DFJ-10

DFJ-50

DFJ-175

DFJ-600

DFJ-12

DFJ-60

DFJ-200

Data Sheet: 1048

DFJ Class J

Drive Fuse High Speed Fuses

Time-Current Characteristic Curves—Average Melt

Current Limitation Curves

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

126

High Speed Fuses

Dimensions - in

Catalog Number

Fig. B

C

D

Thread Depth

FWA-1000AH-2000AH

1

2.0

1.0

Tapped 

3

8

”-24 x 

1

2

FWA-2500AH-3000AH

1

3.0

1.5

Tapped 

1

2

”-20 x 

1

2

FWA-4000AH

2

3.5

1.5

1.5

Tapped 

1

2

”-20 x 

1

2

1mm = 0.0394˝ / 1˝ = 25.4mm

Fig. 1: 1000-3000A

Fig. 2: 4000A

1.875

B

C

1.875

C

B

D

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of the
applied working voltage,
Eg, (rms) at a power 

factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Catalog Numbers

Electrical Characteristics

I

2

t (A

2

Sec)

Catalog

Rated Current

Clearing

Watts

Numbers

RMS-Amps

Pre-arc

at 130V

Loss

FWA-1000AH

1000

170000

460000

60

FWA-1200AH

1200

270000

730000

70

FWA-1500AH

1500

520000

1400000

78

FWA-2000AH

2000

860000

2400000

108

FWA-2500AH

2500

1500000

4100000

130

FWA-3000AH

3000

2100000

5700000

150

FWA-4000AH

4000

3400000

9200000

257

• Watts loss provided at rated current.
• See accessories on page 141.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

North American — FWA 130V:  1000-4000A

FWA

Specifications
Description:

North American

style flush-end high speed fuses.

Dimensions:

See Dimensions

illustrations.

Ratings:

Volts: — 130Vac

Amps: — 1000-4000A

IR: — 200kA RMS Sym.

— 50kA @130Vdc

Agency Information:

CE, UL Recognized JFHR2.E91958

on 1000-2000A fuses

Electrical Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

130

104

65

26

1.5

1.0

0.5

0.3

0.2

0.15

E

g

K

U

L

E

g

200

100

100

150

50

300

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

Data Sheet: 720001

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

127

High Speed

Fuses

North American — FWA 130V:  1000-4000A

FWA 1000-4000A: 130V

Time-Current Curve

10

3

2

2

4

6

8

2

10

4

2

4

6

8

10

5

Prospective Current In Amps RMS

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

V

irtual Pr

e-Ar

cing Time In Seconds

6
4

2

6

2

4

10

–1

10

–2

10

–3

10

–4

10

2

10

3

10

4

FWA-4000AH

FWA-3000AH

FWA-2500AH

FWA-2000AH

FWA-1500AH

FWA-1200AH

FWA-1000AH

FWA-4000AH

FWA-3000AH

FWA-2500AH

FWA-2000AH

FWA-1500AH

FWA-1200AH

FWA-1000AH

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Thr

ough Curr

ent

2

6

4

2

6

4

2

2

4

6

2

4

6

2

4

6

10

4

10

5

10

3

10

4

10

5

10

3

Peak Let-Through Curve

Data Sheet: 35785301

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

128

High Speed Fuses

2.656

1.936

2.188

1.156

0.312

0.438

0.750

1.000

0.125

Dimensions - in

Fig. 1: 70-400A

1.500

0.250

3.500

2.438

1.250

1.000

0.406

Fig. 2: 500-1000A

1mm = 0.0394” / 1” = 25.4mm

North American — FWA 150V:  70-1000A

FWA

Specifications
Description:

North American style 

stud-mount  fuses.

Dimensions:

See Dimensions 

illustrations.

Ratings:

Volts: — 150Vac/dc*

Amps: — 70-1000A

IR: — 100kA Sym. (70-400A)

— 200kA Sym. (450-1000A)

— 20kA @150Vdc (70-800A)

— 100kA @ 80Vdc (70-1000A)

*1000A rated @ 80Vdc.

Agency Information:

CE, UL Recognized JFHR2.E91958

Electrical Characteristics

Total Clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor 
of 15% are given in the 
electrical characteristics. For
other voltages, the clearing 
I

2

t is found by multiplying by 

correction factor, K, given as
a function of applied working
voltage, Eg, (rms).

Arc Voltage

This curve gives the peak
arc voltage, UL, which may

appear across the fuse 
during its operation as a
function of the applied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Watts

Number

RMS-Amps

Pre-arc

at 150V

Loss

FWA-70B

70

470

4000

6.9

FWA-80B

80

670

6000

7.7

FWA-100B

100

1200

12000

9.0

FWA-125B

125

1870

18000

11.2

FWA-150B

150

2700

26000

13.5

FWA-200B

200

4780

45000

17.6

FWA-250B

250

7470

70000

22.5

FWA-300B

300

10760

100000

27.0

FWA-350B

350

15700

140000

30.6

FWA-400B

400

20300

180000

35.2

FWA-500A

500

39000

120000

35.0

FWA-600A

600

46000

140000

47.0

FWA-700A

700

75000

220000

49.0

FWA-800A

800

92000

280000

58.0

FWA-1000A

1000

170000

510000

60.0

• Watts loss provided at rated current.
• See accessories on page 141.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

150

102

70

22

1.5

1.0

0.5

0.3

0.2

0.15

Eg

K

1)

2)

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

U

L

E

g

200

100

100

150

50

300

1) 500-1000A Range
2) 70-400A Range

Data Sheet: 720002

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

129

High Speed

Fuses

North American — FWA 150V:  70-1000A

Prospective Current In Amps RMS

V

irtual Pr

e-Ar

cing Time In Seconds

10

2

2

4

6

8

10

3

2

4

6

8

10

4

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

10

–1

10

–2

10

–3

10

–4

10

2

10

3

10

4

FWA-1000A

FWA-800A

FWA-700A

FWA-600A

FWA-500A

FWA-200A

FWA-400A

FWA-350A

FWA-300A

FWA-250A

FWA-150A

FWA-70A
FWA-80A
FWA-100A
FWA-125A

FWA 70-1000A: 150V

Time-Current Curve

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Thr

ough Curr

ent

2

6

4

2

6

4

2

6

4

2

4

6

2

4

6

2

4

6

10

2

10

3

10

4

10

6

10

2

10

3

10

4

10

5

2

FWA-400A

FWA-350A

FWA-300A

FWA-250A

FWA-200A

FWA-150A

FWA-100A

FWA-80A

FWA-70A

Peak Let-Through Curve

Data Sheet: 35785310

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

130

High Speed Fuses

North American — FWX 250V: 35-2500A

FWX

Specifications
Description:

North American

style stud-mount and flush-end
fuses.

Dimensions:

See Dimensions

illustrations.

Ratings:

Volts: — 250Vac/dc

Amps: — 35-2500A

IR: — 200kA RMS Sym.

50kA@250Vdc (35-800A)

Agency Information:

CE, UL Recognized JFHR2.E56412

& CSA Component Acceptance file Class 1422-30, (53787)
on 35-800A fuses (50kA IR @250Vdc).

Electrical
Characteristics

Total Clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor
of 15% are given in the
electrical characteristics.
For other voltages, the
clearing I

2

t is found by 

multiplying by correction
factor, K, given as a 
function of applied working
voltage, Eg, (rms).

Arc Voltage

This curve gives the peak
arc voltage, UL, which may

appear across the fuse 
during its operation as a
function of the applied 
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current is
given in the electrical char
acteristics. The curve allows 
the calculation of the power 
losses at load currents lower
than the rated current . The
correction factor, Kp , is 
given as a function of the 
RMS load current, Ib , in % 
of the rated current .

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Watts

Number

RMS-Amps

Pre-arc

at 250V

Loss

FWX-35A

35

50

230

4.2

FWX-40A

40

60

310

5.2

FWX-45A

45

80

390

5.7

FWX-50A

50

100

520

6.0

FWX-60A

60

140

740

8.1

FWX-70A

70

330

1400

7.2

FWX-80A

80

430

1850

8.1

FWX-90A

90

570

2450

9.0

FWX-100A

100

740

3150

10.0

FWX-125A

125

1130

4850

12.5

FWX-150A

150

1620

6950

15.7

FWX-175A

175

2170

9300

18.5

FWX-200A

200

2790

12000

22

FWX-225A

225

3210

14700

24

FWX-250A

250

3960

18100

27

FWX-275A

275

4720

21600

31

FWX-300A 300

6000

27300

32

FWX-350A

350

10600

48600

39

FWX-400A

400

14500

66100

44

FWX-450A

450

22100

101000

49

FWX-500A

500

28000

128000

54

FWX-600A

600

41100

188000

62

FWX-700A

700

48800

190000

72

FWX-800A

800

59000

230000

84

FWX-1000AH

1000

44000

360000

100

FWX-1200AH

1200

92000

750000

103

FWX-1500AH

1500

120000

880000

140

FWX-1600AH

1600

160000

1200000

140

FWX-2000AH

2000

320000

2300000

151

FWX-2500AH

2500

670000

4700000

163

• Watts loss provided at rated current.     • See accessories on page 141.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low

energy let-through (I

2

t)

• Superior cycling capability

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

1.5

1.0

0.5

0.3

0.2

0.15

75

125

300

200

250

E

g

K

1)

2)

U

L

1.4
1.2

10

3

800

600

500

400

300

200

50

100

150

200

250

E

g

1)

2)

1) 35-800A Range
2) 1000-2500A Range

1) 35-800A Range
2) 1000-2500A Range

A

E

D

C

F

J

G

B

H

A

B

C

A

B

C

D

Fig. 1:

35-800A

Fig. 2:

1000-1200A

Fig. 3:

1500-2500A

Dimensions - in

Tapped

Amp

Thread

Range

Fig. A

B

C

D

E

F

G

H

J

Depth

35-60

1

3.19 0.81 1.59 2.59 2.25 0.34 0.63 0.13 0.52 —

70-200

1

3.13 1.22 1.59 2.44 2.19 0.34 1.00 0.19 0.47 —

225-600

1

3.84 1.50 1.59 2.94 2.25 0.41 1.00 0.25 0.75 —

700-800

1

3.84 2.00 1.59 3.03 2.28 0.41 1.50 0.25 0.78 —

1000-1200

2

2.59 3.00 1.50 —

3

8

”-24 x 

1

2

1500-2500

3

2.59 3.50 1.50 1.50 —

3

8

”--24 x 

1

2

1mm = 0.0394” / 1” = 25.4mm

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Data Sheet: 720005

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

131

High Speed

Fuses

North American — FWX 250V: 35-2500A

10

4

10

3

10

2

10

2

10

3

10

4

10

1

10

0

10

–1

10

–2

10

–3

10

–4

2

Prospective Current In Amps RMS

V

irtual Pr

e-ar

cing Time In Seconds

FWX-800A

FWX-600A

FWX-500A

FXW-400A

FWX-350A

FWX-200A

FWX-150A

FWX-70A

FWX-60A

FWX-40A

FWX-35A

FWX-100A

10

3

2

2

4

6

8

2

10

4

2

4

6

8

10

5

2

4

6

2

6
4

10

0

2

6
4

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

10

–1

10

–2

10

–3

10

–4

10

2

10

1

10

3

10

4

FWX-2500AH

FWX-2000AH

FWX-1600AH

FWX-1500AH

FWX-1200AH

FWX-1000AH

Prospective Current In Amps RMS

V

irtual Pr

e-Ar

cing Time In Seconds

FWX 1000-2500A(H): 250V

Time-Current Curve

FWX 35-800A: 250V

Time-Current Curve

FWX-150A
FWX-100A
FWX-70A
FWX-60A
FWX-45A
FWX-35A

FWX-200A

FWX-300A

FWX-400A

FWX-600A

FWX-800A

10

2

10

3

10

4

10

5

10

2

10

3

10

4

10

5

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

A

B

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Thr

ough Curr

ent

2

6

4

2

6

4

2

4

6

2

4

6

2

4

6

10

3

10

4

10

5

FWX-2000AH

FWX-1600AH

 FWX-1500AH

FWX-1200AH

 FWX-1000AH

10

3

10

4

10

5

FWX-2500AH

Peak Let-Through Curve

Peak Let-Through Curve

Data Sheet: 359

Data Sheet: 35785299

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

132

High Speed Fuses

North American — FWH 500V:  35-1600A

FWH

Specifications
Description:

North American style

stud-mount fuses.

Dimensions:

See Dimensions 

illustration.

Ratings:

Volts: — 500Vac/dc (35-800A only)

Amps: — 35-1600A

IR: — 200kA Sym.

— 50kA @ 500Vdc (35-800A)

Agency Information:

CE, UL Recognition JFHR2.E91958

FWH-_B (35-200A, 1000-1200A), JFHR2.E56412 
FWH-_A (225-600A), CSA Component Acceptance Class
1422-30, File 53787 (35-1600A).

Electrical Characteristics

Total Clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor of
15% are given in the electrical
characteristics. For other 
voltages, the clearing I

2

t is

found by multiplying by 
correction factor, K, given as a
function of applied working
voltage, Eg, (rms).

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power 
factor of 15%.

Power Losses

Watts loss at rated 
current is given in the
electrical characteristics.
The curve allows the 
calculation of the power
losses at load currents
lower than the rated 
current. The correction
factor, Kp, is given as a

function of the RMS load
current, Ib, in % of the
rated current.

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Watts

Numbers

RMS-Amps

Pre-arc

at 500V

Loss

FWH-35B

35

34

150

8

FWH-40B

40

76

320

7.5

FWH-45B

45

105

450

7.5

FWH-50B

50

135

670

7.5

FWH-60B

60

210

900

9.9

FWH-70B

70

210

900

10.6

FWH-80B

80

305

1400

12.7

FWH-90B

90

360

1600

15

FWH-100B

100

475

2000

17

FWH-125B

125

800

3500

25

FWH-150B

150

1100

4600

30

FWH-175B

175

1450

6200

35

FWH-200B

200

1900

8500

40

FWH-225A

225

4600

23300

39

FWH-250A

250

6300

32200

41

FWH-275A

275

7900

40300

46

FWH-300A

300

9800

49800

51

FWH-325A

325

13700

63800

53

FWH-350A

350

14500

72900

58

FWH-400A

400

19200

96700

65

FWH-450A

450

24700

127000

74

FWH-500A

500

29200

149000

84

FWH-600A

600

41300

206000

108

FWH-700A

700

55000

298000

120

FWH-800A

800

76200

409000

129

FWH-1000A

1000

92000

450000

145

FWH-1200A

1200

122000

600000

180

FWH-1400A

1400

200000

1000000

210

FWH-1600A

1600

290000

1400000

230

• Watts loss provided at rated current.     • See accessories on page 141.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low 

energy let-through (I

2

t)

• Superior cycling capability

500

400

250

100

1.5

1.0

0.5

0.3

0.2

0.15

E

g

K

1)

2)

U

L

2.0

1.6

1.2

10

3

800

600

500

400

300

100

400

300

200

500

E

g

1

2)

1)

1) 35-200 & 1000-1600A Range
2) 225-800A Range

A

E

D

C

F

J

G

B

H

10.219

3.219

0.625

4.25

0.75

3.5

6.219

0.125

0.5

1.625

1.750

8.969

Fig. 1: 35-1200A

Fig. 2: 1400-1600A

Dimensions - in

Amp
Range

Fig. A

B

C

D

E

F

G

H

J

35-60

1

3.188 0.813 1.593 2.541 2.193 0.344 0.719 0.125 0.518

70-100

1

3.625 0.947 1.736 2.853 2.807 0.352 0.750 0.125 0.375

125-200

1

3.625 1.156 1.836 2.892 2.768 0.344 1.000 0.188 0.406

225-400

1

4.340 1.500 2.090 3.440 2.750 0.410 1.000 0.250 0.750

450-600

1

4.340 2.000 2.090 3.530 2.780 0.410 1.500 0.250 0.780

700-800

1

6.340 2.500 2.090 4.970 3.440 0.530 2.000 0.380 1.300

1000-1200

1

6.969 3.000 3.219 5.465 4.475 0.625 2.375 0.438 1.120

1400-1600

2

See Drawing

1mm = 0.0394” / 1” = 25.4mm

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

1) 35-800A Range
2) 1000-1600A Range

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Data Sheet: 720007

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

133

High Speed

Fuses

North American — FWH 500V:  35-1600A

2

4

6

8

10

2

2

2

4

6

8

2

10

3

2

4

6

8

10

4

2

4

6

2

6
4

2

6
4

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

10

0

10

1

10

–1

10

–2

10

–3

10

–4

10

2

10

3

10

4

FWH-90B

FWH-80B

FWH-125B

FWH-100B

FWH-175B
FWH-200B

FWH-150B

FWH-60B
FWH-70B

FWH-50B

FWH-45B

FWH-40B

FWH-35B

FWH-1200A
FWH-1400A

FWH-900A
FWH-1000A

FWH-1600A

Prospective Current In Amps RMS

10

–3

10

–2

10

–1

10

0

10

1

10

2

10

3

10

–4

FWH-300A

FWH-400A

FWH-500A

FWH-600A

FWH-800A

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

10

2

10

3

10

4

10

5

FWH 250-800A: 500V

Time-Current Curve

FWH 35-200A(B) & 900-1600A(A): 500V

Time-Current Curve

FWH-200B

FWH-150B

FWH-125B

FWH-100B

FWH-80B

FWH-60B

FWH-50B

FWH-35B

FWH-40B

FWH-1000A

FWH-1200A

FWH-1400A

FWH-1600A

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Thr

ough Curr

ent

2

4

2

6

6

4

2

6

4

2

4

6

2

4

6

2

4

6

2

10

2

10

3

10

4

10

5

10

2

10

3

10

4

10

5

FWH-800A
FWH-600A
FWH-500A
FWH-400A
FWH-300A
FWH-250A

10

2

10

5

10

4

10

3

10

3

10

4

10

5

10

2

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Thr

ough Curr

ent

A

B

Peak Let-Through Curve

Peak Let-Through Curve

Data Sheet: 35785304

Data Sheet: 360

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

134

High Speed Fuses

North American — KAC 600V:  1-1000A

F

G

A

C

B1

H

D

Fig. 1: 1-30 & 450-1000A

A

B3

B2

C

E

D

F

H

G

Fig. 2: 35-400A

Dimensions - in

KAC

Specifications
Description:

North American style 

stud-mount fuses. These 600V fuses are 
supplied as replacements only. For new
installations, Bussmann recommends the
700V FWP Series fuse.

Dimensions:

See Dimensions illustrations.

Ratings:

Volts: — 600Vac

Amps: — 1-1000A

IR: — 200kA RMS Sym.

Agency Information:

CE, UL Recognition

JFHR2.E56413 on 1-600A only.

Catalog Numbers (Amps)

KAC-1

KAC-25

KAC-175

KAC-2

KAC-30

KAC-200

KAC-3

KAC-35

KAC-225

KAC-4

KAC-40

KAC-250

KAC-5

KAC-45

KAC-300

KAC-6

KAC-50

KAC-350

KAC-7

KAC-60

KAC-400

KAC-8

KAC-70

KAC-450

KAC-9

KAC-80

KAC-500

KAC-10

KAC-90

KAC-600

KAC-12

KAC-100

KAC-700

KAC-15

KAC-110

KAC-800

KAC-17.5

KAC-125

KAC-1000

KAC-20

KAC-150

• See accessories on page 141.

Features and Benefits

• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• Power converters/rectifiers
• Reduced voltage starters

Data Sheet: 720009

Amp
Range

Fig.

A

B1

B2

B3

C

D

E

F

G

H

1-30A

1

2.875

2.500

1.875

0.406

0.563

0.063

0.257

35-60A

2

4.375

3.750

3.500

2.750

0.625

0.343

0.813

0.094

0.468

70-100A

2

5.000

4.063

3.656

2.750

0.750

0.406

1.000

0.125

0.609

110-200A

2

5.140

4.390

3.766

2.906

1.000

0.406

1.500

0.188

0.718

225-400A

2

6.182

4.815

4.565

3.000

1.625

0.562

2.000

0.250

0.687

450-800A

1

6.250

4.750

3.063

2.000

2.500

0.250

0.563

1000A

1

7.250

4.750

3.063

2.750

3.500

0.375

0.563

1mm = 0.0394˝ / 1˝ = 25.4mm

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

135

High Speed

Fuses

North American — KBC 600V:  35-800A

Dimensions - in

Amp
Range

Fig. A

B

C

D

E

F

G

H

I

35-60A

1

4.375

3.750

3.500 2.750 0.343 0.625 0.813 0.094 0.468

70-100A

2

See Drawing

110-200A

1

4.406

3.719

3.594 2.906 0.312 0.875 1.219 0.187 0.375

225-400A

1

5.125

4.188

3.563 2.906 0.406 1.000 1.500 0.250 0.719

450-600A

1

5.125

4.389

3.687 2.875 0.406 1.500 2.000 0.250 0.757

800A

3

See Drawing

1mm = 0.0394” / 1” = 25.4mm

KBC

Specifications
Description:

North American

style stud-mount and flush-end
fuses. These 600V fuses are 
supplied as replacements only. 
For new installations, Bussmann
recommends the  700V FWP
Series fuse.

Dimensions:

See Dimensions

illustrations.

Ratings:

Volts: — 600Vac

Amps: — 35-800A

IR: — 200kA RMS Sym.

Agency Information:

CE, UL Recognition JFHR2.E56412

on 35-600A only.

A

C

B

D

E

F

G

I

H

Fig. 1: 35-60 and 110-600A

Fig. 2: 70-100A

4.000

3.750

2.859

2.500

0.750

0.750

/

•" - 24 ≈ ⁄

/

™"

Fig. 3: 800A

0.750

3.656

4.406

2.906

0.312

1.000

0.125

Catalog Numbers (Amps)

KBC-35

KBC-100

KBC-300

KBC-40

KBC-110

KBC-350

KBC-45

KBC-125

KBC-400

KBC-50

KBC-150

KBC-450

KBC-60

KBC-175

KBC-500

KBC-70

KBC-200

KBC-600

KBC-80

KBC-225

KBC-800

KBC-90

KBC-250

• See accessories on page 141.

Features and Benefits

• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• Power converters/rectifiers
• Reduced voltage starters

Data Sheet: 720010

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

136

High Speed Fuses

North American — FWP 700V:  5-1200A

FWP

Specifications
Description:

North American

style stud-mount fuses.

Dimensions:

See Dimensions

illustrations.

Ratings:

Volts: — 700Vac/dc

Amps: — 5-1200A

IR: — 200kA RMS Sym.

— 50kA @700Vdc

Agency Information:

CE, UL Recognition JFHR2.E91958

FWP-_B (5-100A, 700-1200A), JFHR2.E56412 FWP-_A
(125-600A) & CSA Component Acceptance file Class 
1422-30, (53787) on 5-800A

Electrical Characteristics

Total Clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor of
15% are given in the electrical
characteristics. For other 
voltages, the clearing I

2

t is

found by multiplying by 
correction factor, K, given as 
a function of applied working
voltage, Eg, (rms).

Arc Voltage

This curve gives the peak arc
voltage, UL, which may

appear across the fuse 
during its operation as a
function of the applied 
working voltage, Eg, (rms) at

a power factor of 15%.

Power Losses

Watts loss at rated current is
given in the electrical 
characteristics. The curve
allows the calculation of the
power losses at load 
currents lower than the rated
current. The correction factor,
Kp, is given as a function of

the RMS load current, Ib, in

% of the rated current.

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Watts

Numbers

RMS-Amps

Pre-arc

at 700V

Loss

FWP-5B

5

1.6

10

1.5

FWP-10B

10

3.6

20

4

FWP-15B

15

10

75

5.5

FWP-20B

20

26

180

6

FWP-25B

25

44

340

7

FWP-30B

30

58

450

9

FWP-35B

35

34

160

12

FWP-40B

40

76

320

12

FWP-50B

50

135

600

12

FWP-60B

60

210

950

15.5

FWP-70B

70

305

2000

18

FWP-80B

80

360

2400

21

FWP-90B

90

415

2700

25

FWP-100B

100

540

3500

27

FWP-125A

125

1800

7300

28

FWP-150A

150

2900

11700

32

FWP-175A

175

4200

16700

35

FWP-200A

200

5500

22000

43

FWP-225A

225

7700

31300

45

FWP-250A

250

10500

42500

48

FWP-300A

300

17600

71200

58

FWP-350A

350

23700

95600

65

FWP-400A

400

31000

125000

78

FWP-450A

450

36400

137000

94

FWP-500A

500

45200

170000

107

FWP-600A

600

66700

250000

122

FWP-700A

700

54000

300000

125

FWP-800A

800

78000

450000

140

FWP-900A

900

91500

530000

150

FWP-1000A

1000

120000

600000

170

FWP-1200A

1200

195000

1100000

190

• Watts loss provided at rated current.  • See accessories on page 141.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low

energy let-through (I

2

t)

• Superior cycling capability

700

604

460

316

1.5

1.0

0.5

0.3

0.2

0.15

E

g

K

1)

3)

2)

U

L

2

1.6
1.4
1.2
10

3

8

6
5

4

3

400

300

500

600

700

E

g

1)

2)

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

1) 125-600A Range
2) 35-100 & 700-1200A Range

1) 35-100A Range
2) 125-600A Range
3) 700-1200A Range

A

E

D

C

F

J

G

B

H

Fig. 1: 5-800A

Dimensions - in

Amp
Range

Fig.

A

B

C

D

E

F

G

H

I

5-30

1

2.870 0.563 1.855 2.477 2.477 0.250 0.405 0.063 0.250

35-60

1

4.375 0.813 2.750 3.708 3.312 0.344 0.725 0.125 0.542

70-100

1

4.406 0.947 2.594 3.625 3.563 0.344 0.750 0.125 0.375

125-200

1

5.090 1.500 2.840 4.190 3.500 0.410 1.000 0.250 0.750

225-400

1

5.090 2.000 2.840 4.280 3.530 0.410 1.500 0.250 0.780

450-600

1

7.090 2.500 2.840 5.720 4.190 0.530 2.000 0.380 1.300

700-800

1

6.630 2.000 2.844 5.562 5.062 0.625 1.500 0.250 0.875

900-1000 2

See Drawing

1200

3

See Drawing

1mm = 0.0394” / 1” = 25.4mm

7.594

0.5

3.500

3.844

1.031

0.625

2.750

5.966

5.154

1.375

Fig. 2: 900-1000A

Fig. 3: 1200A

10.844

3.844 

0.625

4.250

0.750

3.500

6.840

0.125

0.500

1.625
1.750

9.590

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Data Sheet: 720012

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

137

High Speed

Fuses

North American — FWP 700V:  5-1200A

2

4

6

8

10

2

2

2

4

6

8

2

10

3

2

4

6

8

10

4

2

4

6

2

6
4

2

6
4

10

1

10

0

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

10

–1

10

–2

10

–3

10

–4

10

2

10

3

10

4

FWP-35B

FWP-80B
FWP-90B
FWP-100B

FWP-60B
FWP-70B

FWP-40B
FWP-50B

FWP-900A

FWP-1200A

FWP-1000A

FWP-800A

FWP-700A

Prospective Current In Amps RMS

V

irtual Pr

e-Ar

cing Time In Seconds

FWP 35-100A(B) & 700-1200A(A): 700V

Time-Current Curve

Prospective Short-Circuit Current

Peak Let-Thr

ough Curr

ent

2

6

4

2

6

4

2

6

4

2

4

6

2

4

6

2

4

6

10

2

10

3

10

4

10

6

10

2

10

3

10

4

10

5

2

FWP-700A

FWP-800A

FWP-1000A

FWP-100B

FWP-35B

FWP-70B

FWP-40B

FWP-50B

FWP-60B

FWP-1200A

Peak Let-Through Curve

2

4

6

8

10

1

2

2

4

6

8

2

10

2

2

4

6

8

10

3

2

4

6

2

6
4

2

6
4

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

10

–1

10

–2

10

–3

10

–4

10

2

10

1

10

0

10

3

10

4

Prospective Current In Amps RMS

V

irtual Pr

e-Ar

cing Time In Seconds

FWP-10B
FWP-15B
FWP-20B

FWP-5B

FWP-30B

FWP-25B

FWP 5-30A(B): 700V

Time-Current Curve

Prospective Short-Circuit Current

Peak Let-Thr

ough Curr

ent

2

4

2

6

6

4

2

6

4

2

4

6

2

4

6

2

4

6

2

4

6

10

1

10

2

10

3

10

4

10

1

10

2

10

3

10

4

10

5

FWP- 5B

FWP-10B

FWP-15B

FWP-20B

FWP-25B

FWP-30B

2

Peak Let-Through Curve

Data Sheet: 35785308

Data Sheet: 35785316

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

138

High Speed Fuses

North American — FWP 700V:  5-1200A

10

–4

10

–3

10

–2

10

–1

10

0

10

1

10

2

10

3

FWP-150A

FWP-200A

FWP-300A

FWP-400A

FWP-600A

Prospective Current In Amperes RMS

V

irtual Pre-Arcing 

T

ime In Seconds

10

2

10

3

10

4

10

5

Prospective Current In Amps RMS

FWP 150-600A: 700V

Time-Current Curve

FWP-600A
FWP-400A
FWP-300A
FWP-200A
FWP-150A

10

2

10

3

10

4

10

5

10

2

10

3

10

4

10

5

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Through Current

A

B

Peak Let-Through Curve

Data Sheet: 361

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

139

High Speed

Fuses

North American — FWJ 1000V:  35-2000A

FWJ

Specifications
Description:

North American

style stud-mount fuses.

Dimensions:

See Dimensions

illustration.

Ratings:

Volts: — 1000Vac/800Vdc

Amps: — 35-2000A

IR: — 25kA (35-200A)

— 100kA (250-2000A)

— 50kA @ 800Vdc 

(35-200A, 450-600A)

Agency Information:

CE, UL

Recognition JFHR8.E91958 on 
35-600A only. 

Electrical Characteristics

Total Clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor of
15% are given in the electrical
characteristics. For other 
voltages, the clearing I

2

t is

found by multiplying by 
correction factor, K, given as
a function of applied working
voltage, Eg, (rms).

Arc Voltage

This curve gives the peak arc
voltage, UL, which may

appear across the fuse 
during its operation as a
function of the applied 
working voltage, Eg, (rms) 

at a power factor of 15%.

Power Losses

Watts loss at rated current is
given in the electrical 
characteristics. The curve
allows the calculation of the
power losses at load 
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Catalog Numbers

Electrical Characteristics

Rated

I2t (A2 Sec)

Catalog

Current

Clearing

Watts

Numbers

RMS-Amps

Pre-arc

at 1000V

Loss

FWJ-35A

35

210

2000

7

FWJ-40A

40

300

2500

8

FWJ-50A

50

470

3500

10

FWJ-60A

60

670

5000

11

FWJ-70A

70

1100

6900

12

FWJ-80A

80

1550

9700

13

FWJ-90A

90

1900

12000

14

FWJ-100A

100

2800

17500

15

FWJ-125A

125

4800

35000

16

FWJ-150A

150

6300

45000

25

FWJ-175A

175

7500

65000

30

FWJ-200A

200

11700

80000

32

FWJ-250A

250

16000

112000

50

FWJ-300A

300

23500

164000

56

FWJ-350A

350

33000

231000

62

FWJ-400A

400

47000

330000

67

FWJ-500A

500

39500

329000

95

FWJ-600A

600

61000

520000

105

FWJ-800A

800

87000

500000

182

FWJ-1000A

1000

190000

1100000

206

FWJ-1200A

1200

370000

2100000

240

FWJ-1400A

1400

470000

2700000

248

FWJ-1600A

1600

700000

4000000

267

FWJ-1800A

1800

925000

5300000

239

FWJ-2000A

2000

1330000

7600000

244

• Watts loss provided at rated current.
• See accessories on page 141.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

2000

1600

1200

800

400

200

600

1000 1400 1800

U

L

E

g

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

1000

800

500

200

1.5

1.0

0.5

0.3

0.2

0.15

Eg

K

A

E

D

C

F

J

G

B

H

Fig. 1: 35-2000A

Dimensions - in

Amp
Range

Fig.

A

B

C

D

E

F

G

H

I

35-60

1

5.000 0.940 3.110 4.235 4.180 0.352 0.750 0.125 0.380

70-100

1

4.932 1.125 3.085 4.266 4.156 0.352 1.000 0.188 0.407

125-200 1

5.685 1.526 3.261 4.803 4.055 0.445 1.000 0.250 0.819

250-400 1

5.768 2.000 3.500 4.811 4.150 0.433 1.500 0.250 0.764

500-600 1

7.201 2.500 3.465 5.984 4.706 0.562 2.000 0.375 1.201

800-2000 1

6.811 3.500 3.312 5.472 4.962 0.625 2.750 0.500 0.880

1mm = 0.0394” / 1” = 25.4mm

Data Sheet: 720027

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

140

High Speed Fuses

North American — FWJ 1000V:  35-2000A

2

4

6

8

10

3

2

2

4

6

8

2

10

4

2

4

6

8

10

5

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

10

–1

10

–2

10

–3

10

–4

10

2

10

3

10

4

FWJ-1800A
FWJ-2000A

FWJ-800A
FWJ-1000A
FWJ-1200A
FWJ-1400A
FWJ-1600A

Prospective Current In Amperes RMS

V

irtual Pre-Arcing 

T

ime In Seconds

Prospective Current in Amps

FWJ 800-2000A: 1000V

Time-Current Curve

Prospective Current In Amps RMS

V

irtual Pr

e-Ar

cing Time In Seconds

10

2

2

2

4

6

8

2

10

3

2

4

6

8

10

4

2

4

6

2

6
4

10

0

2

6
4

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

10

–1

10

–2

10

–3

10

–4

10

2

10

3

10

4

FWJ-125A
FWJ-150A

FWJ-60A

FWJ-100A

FWJ-90A

FWJ-80A

FWJ-70A

FWJ-50A

FWJ-40A

FWJ-600A

FWJ-200A

FWJ-250A

FWJ-300A

FWJ-350A

FWJ-400A

FWJ-500A

FWJ-175A

10

1

FWJ 35-600A: 1000V

Time-Current Curve

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Thr

ough Curr

ent

2

4

2

6

6

4

2

6

4

2

2

4

6

2

4

6

2

4

6

2

4

6

10

2

10

3

10

4

10

5

10

2

10

3

10

4

10

5

FWJ-40A

FWJ-50A

FWJ-60A

FWJ-70A

FWJ-80A

FWJ-90A

FWJ-100A

FWJ-125A

FWJ-150A

FWJ-175A

FWJ-200A

FWJ-500A

FWJ-350A

FWJ-300A

FWJ-250A

FWJ-600A
FWJ-800A

FWJ-2000A
FWJ-1800A
FWJ-1600A
FWJ-1400A
FWJ-1250A
FWJ-1000A

FWJ-400A

Peak Let-Through Curve

Data Sheet: 35785303

Data Sheet: 35785309

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

141

High Speed

Fuses

North American Fuse Accessories

Stud Type

C5268 Series

BS Style

Connector Type

Fixed Center

Fuse Bases (Blocks)

Modular Style

Bussmann offers a comprehensive line of fuse bases that
provide the user with design and manufacturing flexibility.
Two identical half bases make up a Bussmann modular fuse
base. These “split” units can be panel mounted any distance
apart to accommodate any length fuse.

Stud Type (Not sold in pairs)

The simpler design is the C5268 Series modular fuse base.
With this design, the fuse terminal and cable (with 
termination) are mounted on the same stud, minimizing labor
needed for installation. The stud type base is available in the
configuration shown in the table below.

Catalog

Max Fuse

Stud

Stud Dia.

Number

Amp Rating

Height (in)

& Threads

C5268-1

200

1.00

5

16

˝-18

C5268-2

200

1.75

5

16

˝-18

C5268-3

200

0.75

5

16

˝-18

C5268-4

100

1.00

1

4

˝-20

C5268-5

100

1.75

1

4

˝-20

Connector Type

Bussmann also offers a modular style fuse base that utilizes
a tin-plated connector (for wire termination and heat 
dissipation) and a plated-steel stud (for fuse mounting). The 
connector type fuse base is available in the configurations
shown below. Consult Bussmann for additional product
details.

Modular

Max

Max Fuse

Data Sheet

Base Style

Voltage

Amp Rating

Number

1BS101

600

100

1206

1BS102

600

400

1207

1BS103

600

400

1208

1BS104

600

600

1209

BH-0xxx

700

100

1200

BH-1xxx

2500

400

1201

BH-2xxx

5000

400

1202

BH-3xxx

1250

700

1203

Fixed Center Base Style

Bussmann offers a comprehensive line of fixed mount style
fuse bases under the trademark TRON

rectifier fuse blocks.

The cable and fuse connections are similar to the stud type
fuse base — both are mounted on the same stud. Consult
Bussmann for complete product details.

Refer to page 306 for BH style holders.

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

142

Square Body Fuses

General Information

Designed and tested to:

•  IEC 60269: Part 4
•  UL Recognized

Bussmann offers a complete range of square body style
fuses and accessories. Their unique design and 
construction provide:

•  Minimal energy let-through (I

2

t)

•  Low operating temperature
•  Low watts loss

Square body style fuses are a very attractive solution for high
power applications which require a compact design with
superior performance. The construction and design of square
body style fuses make it easy for Bussmann to manufacture
custom products. Our cataloged offering provides only a 
sample of the wide variety of product which 
is available.

Each square body style fuse is available with a number of 
different end fittings. Options include:

•  DIN 43 653
•  DIN 43 620
•  Flush End (Metric/US)
•  French Style
•  US Style

Voltage Rating

All Bussmann square body style fuses are tested to IEC
60269: Part 4. This standard requires a test voltage which is
5% higher than the rated voltage. In North America, fuses are
required to clear only their rated voltage.

Accessories

Square Body style fuses are available with three different
open fuse indicator systems. Options include visual 
indication and indication utilizing a microswitch. Fuse 
blocks are also available for most applications.

Introduction

Square Body Contents

Page

Application Information

143-144

Accessories

Page

Indicator System

212

Fuse Bases

213

Square Body Fuse Ranges

Amps

Volts

AC

DC

10-7500

690

X

50-1400

1250

X

Volts

(IEC/UL)

Size

Class

Fuse Style

Page

aR

DIN 43 653

145-147

000,00

aR

Flush End Contact

145-147

aR

DIN 43 620

148-149

aR

DIN 43 653

150-151

aR

Flush End Contact

152-153

690/700

1*, 1, 2, 3

aR

US Style

154-155

aR

French Style

156-157

aR

Fuse Curves

158-159

1*, 2, 3

aR

DIN 43 620

160-162

4

aR

Flush End Contact

163-164

23, 24

aR

Flush End Contact

165-166

00, 1, 2, 3

aR

DIN 43 620

168-171

00

aR

DIN 43 653

172-173

aR

DIN 43 653

174-175

1*, 1, 2, 3

aR

Flush End Contact

176-177

1000

aR

US Style

178-179

aR

Fuse Curves

180-181

4

aR

Flush End Contact

182-184

24

aR

Flush End Contact

185-186

aR

DIN 43 653

187-188

1*, 1, 2, 3

aR

Flush End Contact

189-190

aR

US Style

191-192

1250/1300

aR

Fuse Curves

193-194

4

aR

Flush End Contact

195-197

23

aR

Flush End Contact

198-199

1000-2000

5

aR

Flush End Contact

200

DC Fuses

201-211

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

143

Square Body Applications

Maximum Permissible Load Current

The rated current value of Bussmann fuses is based on the
ambient temperature in the space immediately below the fuse
of 20°C. The following graph gives correction factors (k) for a
range of temperatures (–40°C to +80°C). Maximum 
permissible continuous load currents can be calculated by
applying the following formula:

Ib

In

 k 

 (1 + 0.05 V) x Kb

where

Ib = Maximum permissible continuous load current
In = Rated current of fuse
k

= Temperature correction factor

v

= Velocity of cooling air in m/s (max. 5 m/s).

Kb = Fuse load constant 1.0 

Temperature Correction Curve

The maximum permissible continuous load current Ib of a
fuse can be checked empirically (i.e., by satisfying the 
formula below) by making simple voltage and temperature
measurements under actual operating conditions after the
fuse has been installed in its operating location and loaded 
at the calculated Ib value:

E

2

 (0.92 + 0.004t) 

 N

E

1

where

E

1

= Voltage drop across fuse after 5 seconds

E

2

= Voltage drop across fuse after 2 hours

t

= Air temperature at start of test (°C)

N = Constant 

Fuse Rated Voltage (IEC) N

690

1.5

1250

1.6

 

Body Cross Section 

Standard fuse program includes barrels with different cross sections. 

Size 

000 00 1

Maximum 

Cross-section 

(mm) 

21 ≈ 36 

30 ≈ 47 

45 ≈ 45 

53 ≈ 53 

61 ≈ 61 

76 ≈ 76 

105 ≈ 105 

 

1 . 4

1 . 2

1

0 . 8

0 . 6

k

4 0

2 0

0

4 0

2 0

6 0

8 0

C

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

144

Square Body Applications

Example Application of Square Body High Speed

Fuses Subject to Overload and Impulse Loading

Select a short-blade indicating fuse with indicator/adapter to
permit the use of a single-pole microswitch for remote 
indication and determine if the fuse selected will meet the 
following application parameters.

Application Parameters

Load Currents Expected

Load Type

Duration

Frequency of Occurrence

Amps

(

1) Normal

Continuous

300A

(2) Overload

60 Seconds

Once Per Hour

500A

(3a)

10 Seconds

2-3 Times Per Week

(3b)

Overload

20 Seconds (max.) Once Per Month

700A

(4) Impulse

0.5 Seconds

Less Than Once Per Month

1100A

Voltage Data

(5) Voltage Applied to Fuse During Fault Conditions

400V

(+10%)

Temperature Data

(6) Temperature Inside Cubicle in Which Fuse is Located (Natural Convection Cooling Only)
60°C

Thyrister Data

(7) Thyrister Peak Voltage Withstand

1000V

(8) Thyrister I

2

t Withstand at 10 Milliseconds*

90,000A

2

s

*Note: The I

2

t withstand of the thyrister may be given for other impulse durations (i.e., 1.5 ms,

3.5 ms, or 8.3 ms); however, the stated fuse I

2

t is valid for all impulse durations of 10 ms or

less.

Application Procedure

Step

Procedure

Remarks

(1)  Select a short-blade fuse to permit

1.1 Taking into consideration only the

mounting of microswitch 170H0069

continuous load current and ambient

temperature, from Table on page 127 

tentatively select fuse 170M3669

400A, 690V).

(2) Determine I

2

t (total clearing) at 440V.

2.1 See Table, page 127. Note I

2

t is

105,000A

2

s at rated voltage of 690V.

2.2 From the figure on page 126, note that

OK

correction factor K = 0.65.

2.3 I

2

t660V

K = I

2

t440V

105,000 

0.65 = 68,250

(3) Determine maximum arc voltage

3.1 From the figure on page 126, note that

at 440V

maximum voltage at 440V is 900V

OK

(4) Determine maximum permissible

4.1 Per page 115 data,

continuous load current Ib.

Ib = In ≈ k ≈ (1 + 0.05V) ≈ Kb

Ib = 400A ≈ 0.8 ≈ (1 + 0) ≈ 1

Ib = 320A

(5) Plot a “line profile” showing the

5.0 Calculate Imax per Table, 

expected load and overload currents.

High Speed Fuse Application Guide

Determine that overload and impulse

page 16, for each overload and impulse

load currents do not exceed their

load.

maximum permissible values.

(Item 2)

5.1 

Imax < 60% ≈ It

500A < 60% 

950A

OK

500A < 570A

(Item 3a)

5.2 Imax < 60% ≈ It

700A < 60% ≈ 1360A

OK

700A < 780A

(Item 3b)

5.3 Imax < 70% ≈ It

700A < 70% ≈ 1150A

OK

700A < 805A

(Item 4)

5.4 Imax < 70% ≈ It

1100A < 70% ≈ 1800A

OK

1100A < 1260A

The tentatively selected fuse 170M3669 with microswitch 170H0069 meets all application parameters; no further
selection would be necessary.

10

2

10

3

10

–2

10

–1

10

0

10

1

10

2

10

3

Current In Amperes

T

ime In Seconds

A

A

170M3669  (400A)

Profile Line

Calculation of Watt Loss

From the Table on page 127, watt loss at 400 amps is 60
watts. The continuous load current of 300A is 75% of rated
current (400A). From page 126, the correction factor 
Kp = 0.5.

Watt Loss 75% = Watt Loss 100% 

≈ 

Kp

= 60W 

0.5

= 30 watts

Special Fuses

Other high speed fuses are available from Bussmann with
voltage ratings of 380 to 10,000V and current ratings up to
10,000A in a single unit configuration. Fuses can be 
supplied with open fuse, “pin” indicators. Various types of
microswitches are also available (see page 212).

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

145

Square Body DIN 43 653 — 690V/700V (IEC/UL):  10-400A

working voltage, Eg,

(rms).

Arc Voltage

This curve gives the
peak arc voltage, UL,

which may appear
across the fuse during
its operation as a 
function of the applied
working voltage, Eg,

(rms) at a power factor of 15%.

Power Losses

Watts loss at rated 
current is given in the
electrical characteristics.
The curve allows the
calculation of the power
losses at load currents
lower than the rated 
current. The correction
factor, Kp, is given as a

function of the RMS load current, Ib, in % of the rated 

current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers

*

690V/700V (IEC/UL)  10-400A

Specifications
Description:

Square body DIN

43-653 stud mount high speed
fuses.

Dimensions:

See dimensions 

illustration.

Ratings:

Volts: — 690Vac (IEC)

— 700Vac (UL)

Amps: — 10-400A

IR: — 200kA RMS Sym.

Agency Information:

CE,

Designed and tested to  IEC
60269: Part 4. UL Recognized
E125085.JFHR2, CSA Certified:
Class 53787, File 1422-30 on
Size 000.

Electrical 
Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given 
in the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied

100 200 300 400 500 600

K

1.5

1.0

0.5

0.4

0.3

0.2

E

g

690

U

L

1.4

1.2

10

3

6

8
7

9

5

4

3

E

g

200

300

400

500

600 690

K

p

30 40 50

60

70

80 90 100%

I

b

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

F

100

78

D

E

G

H

K

54

Indicator

Dimensions - mm

Type -U/80, -/80, -TN/80

Size

D

E

F

G

H

K

000

40

21

20

51

8

2

00

51

30

28

67

10

2

1mm = 0.0394” / 1” = 25.4mm

* Indication for Size 00 fuses is a red pin.

54 Max

64

30

48

62

M8

6

Indicator

Dimensions (mm)

Type 00B/60, 00BTN/60

1mm = 0.0394” / 1” = 25.4mm

For Other Voltage Ratings in This Body Style  

• See page 172 (1000V)

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

146

Square Body DIN 43 653 — 690V/700V (IEC/UL):  10-400A

Catalog Numbers

Catalog Numbers

-TN/80

00BTN/60                           

Electrical Characteristics

-U/80

-/80

Type T

00B/60

Type T

Rated

I

2

t (A

2

Sec)

Without

Visual

Indicator

Visual

Indicator

Current

Clearing

Watts

Indicator

Indicator

for Micro

Indicator

for Micro

Size

RMS-Amps

Pre-arc

at 660V

Loss

170M1308

170M1358

170M1408

10

3.8

25.5

3.0

170M1309

170M1359

170M1409

16

7.2

48

5.5

170M1310

170M1360

170M1410

20

11.5

78

7

170M1311

170M1361

170M1411

25

19

130

9

170M1312

170M1362

170M1412

32

40

270

10

170M1313

170M1363

170M1413

40

69

460

12

170M1314

170M1364

170M1414

50

115

770

15

170M1315

170M1365

170M1415

000

63

215

1450

16

170M1316

170M1366

170M1416

80

380

2550

19

170M1317

170M1367

170M1417

100

695

4650

24

170M1318

170M1368

170M1418

125

1200

8500

28

170M1319

170M1369

170M1419

160

2300

16000

32

170M1320

170M1370

170M1420

200

4200

28000

37

170M1321

170M1371

170M1421

250

7750

51500

42

170M1322

170M1372

170M1422

315

12000

80500

52

170M2608

170M2658

170M2708

170M2758

25

19

130

6

170M2609

170M2659

170M2709

170M2759

32

28.5

195

7

170M2610

170M2660

170M2710

170M2760

40

50

360

9

170M2611

170M2661

170M2711

170M2761

50

95

640

10

170M2612

170M2662

170M2712

170M2762

63

170

1200

12

170M2613

170M2663

170M2713

170M2763

80

310

2100

15

170M2614

170M2664

170M2714

170M2764

00

100

620

4150

20

170M2615

170M2665

170M2715

170M2765

125

1000

6950

25

170M2616

170M2666

170M2716

170M2766

160

1900

13000

30

170M2617

170M2667

170M2717

170M2767

200

3400

23000

35

170M2618

170M2668

170M2718

170M2768

250

6250

42000

45

170M2619

170M2669

170M2719

170M2769

315

10000

68500

55

170M2620

170M2670

170M2720

170M2770

350

13500

91500

60

170M2621

170M2671

170M2721

170M2771

400

18000

125000

70

• Watts loss provided at rated current.
• Microswitch indicator ordered separately.
• See accessories on pages 212-213.
• For fuse curves see page 147.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body Size 000, 00 — 690V/700V (IEC/UL):  10-400A

1x10

1

10

2

10

3

10

4

1x10

–4

10

–3

10

–2

10

–1

10

0

10

1

10

2

10

3

10

4

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

10A

16A

20A

25A

32A

40A

50A

63A

80A

100

A

125

A

160

A

200

A

250

A

315

A

A

A

1x10

1

10

2

10

3

10

4

1x10

–4

10

–3

10

–2

10

–1

10

0

10

1

10

2

10

3

10

4

Prospective Current in Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

25A

32A

40A

50A

63A

80A

100

A

125

A

160

A

200

A

250

A

315

A

350

A

400

A

A

A

Size 00 — 25-400A: 690V

Time-Current Curve

Size 000 — 10-315A: 690V

Time-Current Curve

1x10

1

10

2

10

3

10

4

10

5

2x10

1

10

2

10

3

10

4

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

10A

16A

20A

25A

32A

40A

50A

63A

80A

100A

125A

160A

200A

250A

A

B

315A

1x10

1

10

2

10

3

10

4

10

5

2x10

1

10

2

10

3

10

4

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

25A

32A

40A

50A

63A

80A

100A

125A

160A

200A

250A

315A

350A

400A

A

B

Peak Let-Through Curve

Peak Let-Through Curve

Data Sheet: 17056310

Data Sheet: 172056312

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

147

High Speed

Fuses

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

148

High Speed Fuses

Square Body DIN 43 620 — 690V (IEC/UL):  10-315A

690V (IEC/UL) 10-315A

Specifications

Description:

Square body DIN 43

620 blade style high speed fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 690Vac

Amps: — 10-315A

IR: — 200kA RMS Sym.

Agency Information: 

CE, Designed and tested to IEC

60269: Part 4. UL Recognized E125085.JFHR2. & CSA
Component Acceptance file Class 1422-30, (53787)

Electrical 
Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical characteris-
tics. For other voltages,
the clearing I

2

t is found by

multiplying by correction
factor, K, given as a func-
tion of applied working
voltage, Eg, (rms).

54 Ma

x

79

48

21

6

35

15

I

ndicator

Dimensions - mm

DIN 000 Type T

1mm = 0.0394” / 1” = 25.4mm

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The correc-
tion factor, Kp, is given as

a function of the RMS load
current, Ib, in % of the

rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

149

Catalog Numbers

Catalog Numbers
DIN

Electrical Characteristics

Type T

Rated

I

2

t (A

2

Sec)

Indicator

Current

Clearing

Watts

for Micro

Size

RMS-Amps

Pre-arc

at 660V

Loss

170M1558D

10

4

27

2.5

170M1559D

16

7

51

4

170M1560D

20

11.5

82.5

5

170M1561D

25

19

140

6

170M1562D

32

40

285

7

170M1563D

40

65

490

8.5

170M1564D

000

50

115

815

9.5

170M1565D

63

215

1550

11.5

170M1566D

80

380

2700

15

170M1567D

100

695

4950

16.5

170M1568D

125

1180

8250

21.5

170M1569D

160

2300

16500

25

170M1570D

200

4350

31000

29.5

170M1571D

250

7900

56000

35.5

170M1572D

00

315

12000

84500

45

• Watts loss provided at rated current.
• Microswitch indicator ordered separately. See accessories on pages 212-213.

Rated Current

The rated current of this fuse range has been given with 
copper conductors that have a current density of 1.3A/mm

2

(IEC 60269-4). For conductor cross section according to IEC
60269-1, the fuses with a rated current higher than 125A
must be derated. Please contact Bussmann for 
application assistance.

Square Body DIN 43 620 — 690V (IEC/UL):  10-315A

Size 000 — 10-315A: 690V

Time-Current Curve

Peak Let-Through Curve

Data Sheet: 72056310

High Speed

Fuses

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

150

Square Body DIN 43 653 — 690V/700V (IEC/UL):
40-2000A

690V/700V (IEC/UL)  40-2000A

Specifications

Description: Square body DIN 43
653 stud-mount high speed fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 690Vac (IEC)

— 700Vac (UL)

Amps: — 40-2000A

IR: — 200kA RMS Sym.

Agency Information:

CE,

Designed and tested to  IEC
60269: Part 4. UL Recognized
E125085.JFHR2, CSA Certified:
Class 53787, File 1422-30.

Electrical 
Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

U

L

1.4

1.2

10

3

6

8
7

9

5

4

3

E

g

200

300

400

500

600 690

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

100 200 300 400 500 600 690

K

1.5

1.0

0.5

0.4

0.3

0.2

E

g

1)

2)

1) Rated voltage 600V
2) Rated voltage 550V

A

B

C

D

E

E

6

11

H

Dimensions - mm

Size

A

B

B**

C

C**

D***

E

H

1*

50

104

134

78

108

58

45

22

1

50

108

138

78

108

66

53

25

2

50

108

138

78

108

75

61

25

3

51

109

139

78

108

90

76

30

**Valid for fuses type -/110, -TN/110.
***Microswitch.
1mm = 0.0394” / 1” = 25.4mm

Type -KN/80, -KN/110

Type -/80, -TN/80, -/110, -TN/110.

C

B

A

H

11

6

E

E

D

For Other Voltage Ratings in This Body Style  

• See pages 174 (1000V) and 187 (1250V/1300V)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body DIN 43 653 — 690V/700V (IEC/UL): 
40-2000A

151

Catalog Numbers

-/80

-TN/80

-KN/80

-TN/110

-KN/110

Electrical Characteristics

Visual

Type T

Type K

-/110

Type T

Type K

I

2

t (A

2

Sec)

Watts

Indicator

Indicator

Visual

Indicator

Indicator

Rated

Current

Clearing

Indicator

for Micro

for Micro

for Micro

for Micro

-KN/80

Size

RMS-Amps

Pre-arc

at 660V

Loss

170M3008

170M3058

170M3108

170M3158

170M3208

170M3258

40

40

270

9

170M3009

170M3059

170M3109

170M3159

170M3209

170M3259

50

77

515

11

170M3010

170M3060

170M3110

170M3160

170M3210

170M3260

63

115

770

14

170M3011

170M3061

170M3111

170M3161

170M3211

170M3261

80

185

1250

18

170M3012

170M3062

170M3112

170M3162

170M3212

170M3262

100

360

2450

21

170M3013

170M3063

170M3113

170M3163

170M3213

170M3263

125

550

3700

26

170M3014

170M3064

170M3114

170M3164

170M3214

170M3264

160

1100

7500

30

170M3015

170M3065

170M3115

170M3165

170M3215

170M3265

200

2200

15000

35

170M3016

170M3066

170M3116

170M3166

170M3216

170M3266

1*

250

4200

28500

40

170M3017

170M3067

170M3117

170M3167

170M3217

170M3267

315

7000

46500

50

170M3018

170M3068

170M3118

170M3168

170M3218

170M3268

350

10000

68500

55

170M3019

170M3069

170M3119

170M3169

170M3219

170M3269

400

15000

105000

60

170M3020

170M3070

170M3120

170M3170

170M3220

170M3270

450

21000

140000

65

170M3021

170M3071

170M3121

170M3171

170M3221

170M3271

500

27000

180000

70

170M3022

170M3072

170M3122

170M3172

170M3222

170M3272

550

34000

230000

75

170M3023

170M3073

170M3123

170M3173

170M3223

170M3273

630

48500

325000

80

170M4008

170M4058

170M4108

170M4158

170M4208

170M4258

200

1650

11500

45

170M4009

170M4059

170M4109

170M4159

170M4209

170M4259

250

3100

21000

55

170M4010

170M4060

170M4110

170M4160

170M4210

170M4260

315

6200

42000

58

170M4011

170M4061

170M4111

170M4161

170M4211

170M4261

350

8500

59000

60

170M4012

170M4062

170M4112

170M4162

170M4212

170M4262

400

13500

91500

65

170M4013

170M4063

170M4113

170M4163

170M4213

170M4263

450

17000

120000

70

170M4014

170M4064

170M4114

170M4164

170M4214

170M4264

1

500

25000

170000

72

170M4015

170M4065

170M4115

170M4165

170M4215

170M4265

550

34000

230000

75

170M4016

170M4066

170M4116

170M4166

170M4216

170M4266

630

52000

350000

80

170M4017

170M4067

170M4117

170M4167

170M4217

170M4267

700

69500

465000

85

170M4018

170M4068

170M4118

170M4168

170M4218

170M4268

800

105000

725000

95

170M4019

170M4069

170M4119

170M4169

170M4219

170M4269

‡900

155000

‡850000

100

170M5008

170M5058

170M5108

170M5158

170M5208

170M5258

400

11000

74000

65

170M5009

170M5059

170M5109

170M5159

170M5209

170M5259

450

15500

105000

70

170M5010

170M5060

170M5110

170M5160

170M5210

170M5260

500

21500

145000

75

170M5011

170M5061

170M5111

170M5161

170M5211

170M5261

550

28000

190000

80

170M5012

170M5062

170M5112

170M5162

170M5212

170M5262

630

41000

275000

90

170M5013

170M5063

170M5113

170M5163

170M5213

170M5263

2

700

60500

405000

95

170M5014

170M5064

170M5114

170M5164

170M5214

170M5264

800

86000

575000

105

170M5015

170M5065

170M5115

170M5165

170M5215

170M5265

900

125000

840000

110

170M5016

170M5066

170M5116

170M5166

170M5216

170M5266

1000

180000

1250000

115

170M5017

170M5067

170M5117

170M5167

170M5217

170M5267

1100

245000

1600000

120

170M5018

170M5068

170M5118

170M5168

170M5218

170M5268

1250

365000

2400000

130

170M6008

170M6058

170M6108

170M6158

170M6208

170M6258

500

14000

95000

95

170M6009

170M6059

170M6109

170M6159

170M6209

170M6259

550

19500

135000

100

170M6010

170M6060

170M6110

170M6160

170M6210

170M6260

630

31000

210000

105

170M6011

170M6061

170M6111

170M6161

170M6211

170M6261

700

44500

300000

110

170M6012

170M6062

170M6112

170M6162

170M6212

170M6262

800

69500

465000

115

170M6013

170M6063

170M6113

170M6163

170M6213

170M6263

900

100000

670000

120

170M6014

170M6064

170M6114

170M6164

170M6214

170M6264

3

1000

140000

945000

125

170M6015

170M6065

170M6115

170M6165

170M6215

170M6265

1100

190000

1300000

130

170M6016

170M6066

170M6116

170M6166

170M6216

170M6266

1250

290000

1950000

140

170M6017

170M6067

170M6117

170M6167

170M6217

170M6267

1400

370000

2450000

155

170M6018

170M6068

170M6118

170M6168

170M6218

170M6268

1500

460000

3100000

160

170M6019

170M6069

170M6119

170M6169

170M6219

170M6269

1600

580000

3900000

160

170M6020

170M6070

170M6120

170M6170

170M6220

170M6270

†1800

880000

†5250000

165

170M6021

170M6071

170M6121

170M6171

170M6221

170M6271

‡2000

1150000

‡6350000

175

†Rated voltage (IEC) 600V.
‡Rated voltage (IEC) 550V.
• Watts loss provided at rated current.
• Microswitch indicator ordered separately. See accessories on pages 212-213.
• For fuse curves see pages 158 and 159.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

Catalog Numbers

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

152

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Square Body Flush End Contact — 690V/700V (IEC/UL):
40-2000A

K

p

30 40 50

60

70

80 90 100%

I

b

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

690V/700V (IEC/UL)  40-2000A

Specifications

Description:

Square body flush

end contact high speed fuses.

Dimensions:

See dimensions

illustrations.

Ratings:

Volts: — 690Vac (IEC)

— 700Vac (UL)

Amps: — 40-2000A

IR: — 200kA RMS Sym.

Agency Information:

CE, Designed and tested to IEC

60269: Part 4. UL Recognized E125085.JFHR2, CSA
Certified: Class 53787, File 1422-30.

Electrical 
Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

A

B

D

E

E

H

G

F

Dimensions - mm

Type -B/-, -BKN/-, -G/-, -GKN/-

Size

A

B

D

E

F

F** (in)

G

H

1*

50

51

59

45

M8

5

16

” - 18 UNC-2B

5

ø17

1

50

51

69

53

M8

5

16

” - 18 UNC-2B

8

ø20

2

50

51

77

61

M10

3

8

” - 16 UNC-2B

10

ø24

3

51

53

92

76

M12

1

2

” - 13 UNC-2B

10

ø30

**Valid for fuses type -G/- & -GKN/-.
NB: B = 65 for:

Size 2, 1100-1250A
Size 3, 1600-2000A

1mm = 0.0394” / 1” = 25.4mm

U

L

1.4

1.2

10

3

6

8
7

9

5

4

3

E

g

200

300

400

500

600 690

K

1.5

1.0

0.5

0.4

0.3

0.2

E

g

1)

2)

100 200 300 400 500 600 690

1) Rated voltage 600V.
2) Rated voltage 550V

For Other Voltage Ratings in This Body Style  

• See pages 176 (1000V) and 189 (1250V/1300V)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

153

Square Body Flush End Contact — 690V/700V (IEC/UL):
40-2000A

Catalog Numbers

-BKN/-

-GKN/-

Electrical Characteristics

-B/-

Type K

-G/-

Type K

Rated

I

2

t (A

2

Sec)

Visual

Indicator

Visual

Indicator

Current

Clearing

Watts

Indicator

for Micro

Indicator

for Micro

Size

RMS-Amps

Pre-arc

at 660V

Loss

170M3408

170M3458

170M3508

170M3558

40

40

270

9

170M3409

170M3459

170M3509

170M3559

50

77

515

11

170M3410

170M3460

170M3510

170M3560

63

115

770

14

170M3411

170M3461

170M3511

170M3561

80

185

1250

18

170M3412

170M3462

170M3512

170M3562

100

360

2450

21

170M3413

170M3463

170M3513

170M3563

125

550

3700

26

170M3414

170M3464

170M3514

170M3564

160

1100

7500

30

170M3415

170M3465

170M3515

170M3565

200

2200

15000

35

170M3416

170M3466

170M3516

170M3566

1*

250

4200

28500

40

170M3417

170M3467

170M3517

170M3567

315

7000

46500

50

170M3418

170M3468

170M3518

170M3568

350

10000

68500

55

170M3419

170M3469

170M3519

170M3569

400

15000

105000

60

170M3420

170M3470

170M3520

170M3570

450

21000

140000

65

170M3421

170M3471

170M3521

170M3571

500

27000

180000

70

170M3422

170M3472

170M3522

170M3572

550

34000

230000

75

170M3423

170M3473

170M3523

170M3573

630

48500

325000

80

170M4408

170M4458

170M4508

170M4558

200

1650

11500

45

170M4409

170M4459

170M4509

170M4559

250

3100

21000

55

170M4410

170M4460

170M4510

170M4560

315

6200

42000

58

170M4411

170M4461

170M4511

170M4561

350

8500

59000

60

170M4412

170M4462

170M4512

170M4562

400

13500

91500

65

170M4413

170M4463

170M4513

170M4563

450

17000

120000

70

170M4414

170M4464

170M4514

170M4564

1

500

25000

170000

72

170M4415

170M4465

170M4515

170M4565

550

34000

230000

75

170M4416

170M4466

170M4516

170M4566

630

52000

350000

80

170M4417

170M4467

170M4517

170M4567

700

69500

465000

85

170M4418

170M4468

170M4518

170M4568

800

105000

725000

95

170M4419

170M4469

170M4519

170M4569

‡900

155000

‡850000

100

170M5408

170M5458

170M5508

170M5558

400

11000

74000

65

170M5409

170M5459

170M5509

170M5559

450

15500

105000

70

170M5410

170M5460

170M5510

170M5560

500

21500

145000

75

170M5411

170M5461

170M5511

170M5561

550

28000

190000

80

170M5412

170M5462

170M5512

170M5562

630

41000

275000

90

170M5413

170M5463

170M5513

170M5563

2

700

60500

405000

95

170M5414

170M5464

170M5514

170M5564

800

86000

575000

105

170M5415

170M5465

170M5515

170M5565

900

125000

840000

110

170M5416

170M5466

170M5516

170M5566

1000

180000

1250000

115

170M5417

170M5467

170M5517

170M5567

1100

245000

1600000

120

170M5418

170M5468

170M5518

170M5568

1250

365000

2400000

130

170M6408

170M6458

170M6508

170M6558

500

14000

95000

95

170M6409

170M6459

170M6509

170M6559

550

19500

135000

100

170M6410

170M6460

170M6510

170M6560

630

31000

210000

105

170M6411

170M6461

170M6511

170M6561

700

44500

300000

110

170M6412

170M6462

170M6512

170M6562

800

69500

465000

115

170M6413

170M6463

170M6513

170M6563

900

100000

670000

120

170M6414

170M6464

170M6514

170M6564

3

1000

140000

945000

125

170M6415

170M6465

170M6515

170M6565

1100

190000

1300000

130

170M6416

170M6466

170M6516

170M6566

1250

290000

1950000

140

170M6417

170M6467

170M6517

170M6567

1400

370000

2450000

155

170M6418

170M6468

170M6518

170M6568

1500

460000

3100000

160

170M6419

170M6469

170M6519

170M6569

1600

580000

3900000

160

170M6420

170M6470

170M6520

170M6570

†1800

880000

†5250000

165

170M6421

170M6471

170M6521

170M6571

‡2000

1150000

‡6350000

175

†Rated voltage (IEC) 600V.
‡Rated voltage (IEC) 550V.
• Watts loss provided at rated current.
• Microswitch indicator ordered separately. See accessories on pages 212-213.
• For fuse curves see pages 158 and 159.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

Catalog Numbers

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

154

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Square Body US Style — 690V/700V (IEC): 
40-2000A

690V/700V (IEC)  40-2000A

Specifications

Description:

Square body US

style high speed fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 690Vac (IEC)

— 700Vac (UL)

Amps: — 40-200A

IR: — 200kA RMS Sym.

Agency Information: 

CE, Designed and tested to  IEC

60269: Part 4. UL Recognized E125085.JFHR2, CSA
Certified: Class 53787, File 1422-30.

Electrical 
Characteristics

Total Clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor
of 15% are given in the 
electrical characteristics. For
other voltages, the clearing
I

2

t is found by multiplying by

correction factor, K, given as
a function of applied working
voltage, Eg, (rms).

B

C2

D

E

E

6

I

C1

A

Dimensions - mm

Type -FU/-, -FKE/-, FU/115-, -FKE/115

Size

A

B

B**

C1

C1**

C2

C2** D

E

H

I

1*

50

110

148

85

123

72

110

59

45

20

10

1

50

136

157

104

126

78

100

69

53

25

14

2

50

135

159

105

125

78

99

77

61

25

14

3

51

135

155

106

125

77

97

92

76

36

16

**Valid for fuses type -FU/115 & -FKE/115.
1mm = 0.0394” / 1” = 25.4mm

K

1.5

1.0

0.5

0.4

0.3

0.2

1)

2)

100 200 300 400 500 600 690

U

L

1.4

1.2

10

3

6

8
7

9

5

4

3

E

g

200

300

400

500

600 690

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

1) Rated voltage 600V.
2) Rated voltage 550V

For Other Voltage Ratings in This Body Style  

• See pages 178 (1000V) and 191 (1250V/1300V)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

155

Square Body US style — 690V/700V (IEC):  40-2000A

Catalog Numbers

-FKE/-

-FKE/115

Electrical Characteristics

-FU/-

Type K

-FU/115

Type K

Rated

I

2

t (A

2

Sec)

Without

Indicator

Without

Indicator

Current

Clearing

Watts

Indicator

for Micro

Indicator

for Micro

Size

RMS-Amps

Pre-arc

at 660V

Loss

170M3608

170M3658

170M3708

170M3758

40

40

270

9

170M3609

170M3659

170M3709

170M3759

50

77

515

11

170M3610

170M3660

170M3710

170M3760

63

115

770

14

170M3611

170M3661

170M3711

170M3761

80

185

1250

18

170M3612

170M3662

170M3712

170M3762

100

360

2450

21

170M3613

170M3663

170M3713

170M3763

125

550

3700

26

170M3614

170M3664

170M3714

170M3764

160

1100

7500

30

170M3615

170M3665

170M3715

170M3765

200

2200

15000

35

170M3616

170M3666

170M3716

170M3766

1*

250

4200

28500

40

170M3617

170M3667

170M3717

170M3767

315

7000

46500

50

170M3618

170M3668

170M3718

170M3768

350

10000

68500

55

170M3619

170M3669

170M3719

170M3769

400

15000

105000

60

170M3620

170M3670

170M3720

170M3770

450

21000

140000

65

170M3621

170M3671

170M3721

170M3771

500

27000

180000

70

170M3622

170M3672

170M3722

170M3772

550

34000

230000

75

170M3623

170M3673

170M3723

170M3773

630

48500

325000

80

170M4608

170M4658

170M4708

170M4758

200

1650

11500

45

170M4609

170M4659

170M4709

170M4759

250

3100

21000

55

170M4610

170M4660

170M4710

170M4760

315

6200

42000

58

170M4611

170M4661

170M4711

170M4761

350

8500

59000

60

170M4612

170M4662

170M4712

170M4762

400

13500

91500

65

170M4613

170M4663

170M4713

170M4763

1

450

17000

120000

70

170M4614

170M4664

170M4714

170M4764

500

25000

170000

72

170M4615

170M4665

170M4715

170M4765

550

34000

230000

75

170M4616

170M4666

170M4716

170M4766

630

52000

350000

80

170M4617

170M4667

170M4717

170M4767

700

69500

465000

85

170M4618

170M4668

170M4718

170M4768

800

105000

725000

95

170M4619

170M4669

170M4719

170M4769

‡900

155000

‡850000

100

170M5608

170M5658

170M5708

170M5758

400

11000

74000

65

170M5609

170M5659

170M5709

170M5759

450

15500

105000

70

170M5610

170M5660

170M5710

170M5760

500

21500

145000

75

170M5611

170M5661

170M5711

170M5761

550

28000

190000

80

170M5612

170M5662

170M5712

170M5762

630

41000

275000

90

170M5613

170M5663

170M5713

170M5763

2

700

60500

405000

95

170M5614

170M5664

170M5714

170M5764

800

86000

575000

105

170M5615

170M5665

170M5715

170M5765

900

125000

840000

110

170M5616

170M5666

170M5716

170M5766

1000

180000

1250000

115

170M5617

170M5667

170M5717

170M5767

1100

245000

1600000

120

170M5618

170M5668

170M5718

170M5768

1250

365000

2400000

130

170M6608

170M6658

170M6708

170M6758

500

14000

95000

95

170M6609

170M6659

170M6709

170M6759

550

19500

135000

100

170M6610

170M6660

170M6710

170M6760

630

31000

210000

105

170M6611

170M6661

170M6711

170M6761

700

44500

300000

110

170M6612

170M6662

170M6712

170M6762

800

69500

465000

115

170M6613

170M6663

170M6713

170M6763

900

100000

670000

120

170M6614

170M6664

170M6714

170M6764

1000

140000

945000

125

170M6615

170M6665

170M6715

170M6765

3

1100

190000

1300000

130

170M6616

170M6666

170M6716

170M6766

1250

290000

1950000

140

170M6617

170M6667

170M6717

170M6767

1400

370000

2450000

155

170M6618

170M6668

170M6718

170M6768

1500

460000

3100000

160

170M6619

170M6669

170M6719

170M6769

1600

580000

3900000

160

170M6620

170M6670

170M6720

170M6770

†1800

880000

†5250000

165

170M6621

170M6671

170M6721

170M6771

‡2000

1150000

‡6350000

175

†Rated voltage (IEC) 600V.
‡Rated voltage (IEC) 550V.
• Watts loss provided at rated current.
• Microswitch indicator ordered separately. See accessories on pages 212-213.
• For fuse curves see pages 158 and 159.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

Catalog Numbers

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

156

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Square Body French Style — 690V/700V (IEC/UL):
40-1500A

690V/700V (IEC/UL)  40-1500A

Specifications

Description:

Square body French

style high speed fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 690Vac (IEC)

— 700Vac (UL)

Amps: — 40-1500A

IR: — 200kA RMS Sym.

Agency Information:

CE, Designed and tested to  IEC

60269: Part 4. UL Recognized E125085.JFHR2 & CSA
Component Acceptance file Class 1422-30, (53787) on Sizes
(1, 2, 3) only

Electrical 
Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

A

B

C

D

E

J

E

6

H

I

Dimensions - mm

Type -E/-, -EKN/-

Size

A

B

C

D

E

H

I

J

1*

50

102

76

59

45

18

9

13

1

50

111

86

69

53

25

11

11

2

50

126

91

77

61

30

13

12

3

51

126

91

92

76

36

13

13

1mm = 0.0394” / 1” = 25.4mm

K

1.5

1.0

0.5

0.4

0.3

0.2

E

g

100 200 300 400 500 600 690

U

L

1.4

1.2

10

3

6

8
7

9

5

4

3

E

g

200

300

400

500

600 690

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body French Style — 690V/700V (IEC/UL):  40-1500A

157

1x10

2

10

3

10

4

10

5

1x10

–4

10

–3

10

–2

10

–1

10

0

10

1

10

2

10

3

10

4

Prospective Current In Amperes RMS

Vir

tual Pre-Arcing 

Time In Seconds

400A

450A

500A

550A

630A

700A

800A

900A

1000A

1100A

1250A

A

A

Catalog Numbers
-E/

-EKN/-

Electrical Characteristics

Type T

Type K

Rated

I2t (A2 Sec)

Indicator

Indicator

Current

Clearing

Watts

For Micro

for Micro

Size

RMS-Amps

Pre-arc

at 660V

Loss

170M3308

170M3358

40

40

270

9

170M3309

170M3359

50

77

515

11

170M3310

170M3360

63

115

770

14

170M3311

170M3361

80

185

1250

18

170M3312

170M3362

100

360

2450

21

170M3313

170M3363

125

550

3700

26

170M3314

170M3364

160

1100

7500

30

170M3315

170M3365

1*

200

2200

15000

35

170M3316

170M3366

250

4200

28500

40

170M3317

170M3367

315

7000

46500

50

170M3318

170M3368

350

10000

68500

55

170M3319

170M3369

400

15000

105000

60

170M3320

170M3370

450

21000

140000

65

170M3321

170M3371

500

27000

180000

70

170M4308

170M4358

200

1650

11500

45

170M4309

170M4359

250

3100

21000

55

170M4310

170M4360

315

6200

42000

58

170M4311

170M4361

350

8500

59000

60

170M4312

170M4362

400

13500

91500

65

170M4313

170M4363

1

450

17000

120000

70

170M4314

170M4364

500

25000

170000

72

170M4315

170M4365

550

34000

230000

75

170M4316

170M4366

630

52000

350000

80

170M4317

170M4367

700

69500

465000

85

170M4318

170M4368

800

105000

725000

95

170M5308

170M5358

400

11000

74000

65

170M5309

170M5359

450

15500

105000

70

170M5310

170M5360

500

21500

145000

75

170M5311

170M5361

550

28000

190000

80

170M5312

170M5362

2

630

41000

275000

90

170M5313

170M5363

700

60500

405000

95

170M5314

170M5364

800

86000

575000

105

170M5315

170M5365

900

125000

840000

110

170M5316

170M5366

1000

180000

1250000

115

170M6308

170M6358

500

14000

95000

95

170M6309

170M6359

550

19500

135000

100

170M6310

170M6360

630

31000

210000

105

170M6311

170M6361

700

44500

300000

110

170M6312

170M6362

800

69500

465000

115

170M6313

170M6363

3

900

100000

670000

120

170M6314

170M6364

1000

140000

945000

125

170M6315

170M6365

1100

190000

1300000

130

170M6316

170M6366

1250

290000

1950000

140

170M6317

170M6367

1400

370000

2450000

155

170M6318

170M6368

1500

460000

3100000

160

• Watts loss provided at rated current.
• Microswitch indicator ordered separately. See accessories on pages 212-213.
• For fuse curves see pages 158 and 159.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

Catalog Numbers

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

158

Square Body, French Style - Size 1*, 1 — 690V/700V
(IEC/UL): 40-2000A

1

x

10

2

10

3

10

4

10

5

1

x

10

–4

10

–3

10

–2

10

–1

10

0

10

1

10

2

10

3

10

4

Prospective Current 

I

n Amps

V

irtual Pre-Arcing 

T

ime 

I

n Seconds

200A

250A

315

A

350A

400

A

450A

500

A

550A

630

A

700A

800

A

900A

A

A

Size 1 — 200-900A: 690V

Time-Current Curve

Size 1* — 40-630A: 690V

Time-Current Curve

1x10

2

10

3

10

4

10

5

10

6

2x10

2

10

3

10

4

10

5

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Through Current

50A

40A

63A

80A

100A

125A

160A

200A

250A

315A

350A

400A

450A

500A

550A

630A

A

B

1x10

2

10

3

10

4

10

5

10

6

2x10

2

10

3

10

4

10

5

P

eak Let-Through Current

200A

250A

315A

350A

400A

450A

500A

550A

630A

700A

800A

900A

A

B

Peak Let-Through Curve

Peak Let-Through Curve

900 amp fuse is derated to 550V (IEC).

Data Sheet: 17056316

Data Sheet: 17056314

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

159

Square Body, French Style - Size 2, 3 — 690V/700V
(IEC/UL): 40-2000A

1x10

2

10

3

10

4

10

5

1x10

–4

10

–3

10

–2

10

–1

10

0

10

1

10

2

10

3

10

4

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

400A

450A

500A

550A

630A

700A

800A

900A

1000A

11

0

0

A

1250A

A

A

1x10

2

10

3

10

4

10

5

1x10

–4

10

–3

10

–2

10

–1

10

0

10

1

10

2

10

3

10

4

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

500A 550A

630A

700A

800A

900A

1000

A

11

0

0

A

1250

A

1400A

1500

A

1600A

1800

A

2000A

A

A

Size 3 — 500-2000A: 690V

Time-Current Curve

Size 2 — 400-1250A: 690V

Time-Current Curve

1x10

3

10

4

10

5

10

6

10

7

2x10

3

10

4

10

5

10

6

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

400A

450A

500A

550A

630A

700A

800A

900A

1000A

1100A

1250A

A

B

1x10

3

10

4

10

5

10

6

10

7

2x10

3

10

4

10

5

10

6

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

500A

550A

630A

700A

800A

900A

1000A

1100A

1250A

1400A

1500A

1600A

1800A

2000A

A

B

Peak Let-Through Curve

Peak Let-Through Curve

1800A fuse is derated to 600V (IEC).
2000A fuse is derated to 550V (IEC).

Data Sheet: 17056318

Data Sheet: 17056320

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

160

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Square Body DIN 43 620 — 690V/700V (IEC/UL): 
40-1000A

690V/700V (IEC/UL)  40-1000A

Specifications

Description:

Square body DIN

43 620 blade style high speed
fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 690Vac (IEC)

— 700Vac (UL)

Amps: — 40-1000A

IR: — 200kA RMS Sym.

Agency Information:

CE, Designed and tested to  IEC

60269: Part 4. UL Recognized E125085.JFHR2.

Electrical 

Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

A

B

D

E

F

6

H

Indicator

Dimensions (mm)

Type DIN 1*, DIN 2, DIN 3

Size

A

B

D

E

F

H

1*

69

135

58

45

40

20

2

69

150

71

55

48

26

3

68

150

88

76

60

33

1mm = 0.0394” / 1” = 25.4mm

For Full Range Fuses in This Body Style  

• See page 168

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

161

Square Body DIN 43 620 — 690V/700V (IEC/UL): 
40-600A

Catalog Numbers

Electrical Characteristics

DIN Type T

Rated

I

2

t (A

2

Sec)

Indicator

Current

Clearing

Watts

for Micro

Size

RMS-Amps

Pre-arc

at 660V

Loss

170M3808D

40

40

285

4

170M3809D

50

78

550

4.5

170M3810D

63

120

850

6.5

170M3811D

80

185

1350

8.5

170M3812D

100

360

2600

10

170M3813D

125

550

3900

11

170M3814D

160

1150

8250

12

170M3815D

200

2300

16500

12.5

170M3816D

1*

250

4350

31000

16

170M3817D

315

7300

52000

20

170M3818D

350

10000

73000

21.5

170M3819D

400

16000

115000

60

170M4863D

450

21500

155000

26.3

170M4864D

500

27000

190000

28.5

170M4865D

550

33500

240000

33

170M4866D

630

48500

345000

37.5

170M4867D

700

69500

495000

39

170M5808D

400

11000

79000

29

170M5809D

450

16000

115000

32

170M5810D

500

21500

155000

34

170M5811D

550

29000

215000

36

170M5812D

2

630

41000

295000

42

170M5813D

700

60500

430000

43

170M5814D

800

86000

610000

48

170M5820D

900

125000

895000

52

170M5816D

1000

180000

1300000

53

170M5817D

1100

245000

1750000

56

170M6808D

500

14000

99500

43

170M6809D

550

19500

140000

44

170M6810D

630

31000

220000

45

170M6811D

700

45000

320000

46

170M6812D

800

69500

490000

48

170M6813D

3

900

100000

720000

50

170M6814D

1000

140000

985000

56

170M6892D

1100

190000

1400000

57

170M8554D

1250

300000

2150000

61

170M8555D

1400

380000

2700000

70

170M8556D

1500

470000

3350000

72

170M8557D

1600

585000

4150000

74

• Watts loss provided at rated current.
• Microswitch indicator ordered separately. See accessories on pages 212-213.
• For fuse curves see page 162.

Rated Current

The rated current of this fuse range has been given with 
copper conductors that have a current density of 1.3A/mm

2

(IEC 60269-4). For conductor cross section according to IEC
60269-1, the fuses must be derated. Please contact
Bussmann for application assistance.

Size 1* — 40-630A: 690V

Time-Current Curve

Peak Let-Through Curve

Data Sheet: 17056314

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

Catalog Numbers

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

162

Square Body DIN 43 620 — 690V/700V (IEC/UL): 
40-1000A

Size 3 — 500-2000A: 690V

Time-Current Curve

Peak Let-Through Curve

Size 2 — 400-1250A: 690V

Time-Current Curve

Peak Let-Through Curve

Data Sheet: 17056318

Data Sheet: 17056320

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

163

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of the
applied working voltage,
Eg, (rms) at a power 

factor of 15%.

Power Losses

Watts loss at rated 
current is given in the
electrical characteristics.
The curve allows the 
calculation of the power
losses at load currents
lower than the rated 
current. The correction
factor, Kp, is given as a

function of the RMS load
current, Ib, in % of the

rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Square Body Flush End Contact — 690/700V (IEC/UL): 
1000-4000A

690V (IEC)  1000-4000A

Specifications

Description:

Square body flush

end contact high speed fuses.

Dimensions:

See dimensions

illustrations.

Ratings:

Volts: — 690Vac

Amps: — 1000-4000A

IR: — 200kA RMS Sym.

Agency Information:

CE, Designed and tested to  IEC

60269: Part 4. UL Recognized E125085.JFHR2.

Electrical 
Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

K

1.5

1.0

0.5

0.4

0.3

0.2

E

g

1)

100 200 300 400 500 600 690

K

p

30 40 50

60

70

80 90 100%

I

b

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

1) Rated voltage 500V

U

L

1.4

1.2

10

3

6

8
7

9

5

4

3

E

g

200

300

400

500

600 690

53

105

67

15

F

G

105

Ø4

Ø56

Dimensions - mm

Type 4B/-, 4BKN/-, 4G/-, 4GKN/-

Size

F (in)

G

4B

M10 10 deep

33

4G

1

2

” -13 UNC-2B 10 deep

38

1mm = 0.0394” / 1” = 25.4mm

For Other Voltage Ratings in This Body Style  

• See pages 182 (1000V) and 195 (1250V)

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

164

Square Body Flush End Contact — 690V (IEC): 
1000-4000A

1x10

3

10

4

10

5

10

6

1x10

–4

10

–3

10

–2

10

–1

10

0

10

1

10

2

10

3

10

4

Prospective Current in Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

1000A

1250A

1400

A

1600A

2000

A

2200A

2500

A

3000A

3500

A

4000A

A

A

Size 4 — 1000-4000A: 690V

Time-Current Curve

1x10

3

10

4

10

5

10

6

10

7

2x10

3

10

4

10

5

10

6

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

1000A

1250A

1400A

1600A

2000A

2200A

2500A

3000A

3500A

4000A

A

B

Peak Let-Through Curve

4000A fuse is derated to 500V (IEC).

Catalog Numbers

-BKN/-

-GKN/-

Electrical Characteristics

-B/-

Type K

-G/-

Type K

Rated Current RMS

I

2

t (A

2

Sec)

Watts Loss

Visual

Indicator

Visual

Indicator

Norm.

Liquid

Clearing

Norm.

Liquid

Indicator

for Micro

Indicator

for Micro

Size

Cool.

Cool.

Pre-arc

at 660V

Cool.

Cool.

170M7058

170M7078

170M7098

170M7118

1000

1350

76000

505000

175

315

170M7059

170M7079

170M7099

170M7119

1250

1700

145000

965000

195

355

170M7060

170M7080

170M7100

170M7120

1400

1900

205000

1400000

205

375

170M7061

170M7081

170M7101

170M7121

1600

2200

305000

2050000

220

405

170M7062

170M7082

170M7102

170M7122

4

2000

2700

600000

3950000

245

445

170M7063

170M7083

170M7103

170M7123

2500

3400

1200000

7800000

275

495

170M7064

170M7084

170M7104

170M7124

3000

4100

2000000

13500000

305

555

170M7065

170M7085

170M7105

170M7125

3500

4700

3250000

22000000

325

585

170M7066

170M7086

170M7106

170M7126

†4000

†5400

4700000

†28000000

355

640

†Rated voltage (IEC) 500V.
• Watts loss provided at rated current.
• Liquid Cool. = Liquid cooling. Temperature on the terminals not to exceed 60°C.
• Microswitch indicator ordered separately. See accessories on pages 212-213.

Data Sheet: 17056328

Catalog Numbers

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

165

Square Body Flush End Contact Size 23, 24 — 660V
(IEC): 1000-7500A

660V (IEC) 1000-7500A

Specifications

Description:

High speed

square body fuses, for the 
protection of the power rectifier
section of the equipment.

Dimensions:

See dimensions

illustrations.

Ratings:

Volts: — 660Vac

Amps: — 1000-4000A

IR: — 300kA RMS Sym.

Agency Information:

CE, Designed and tested to  IEC

60269: Part 4. UL Recognized E125085.JFHR2.

Electrical Characteristics

Total clearing I

2

t

The total clearing I

2

t at rated voltage and at power factor of

15% are given in the electrical characteristics. For other 
voltages, the clearing I

2

t is found by multiplying by correction

factor, K, given as a function of applied working voltage, 
Eg, (rms).

Arc Voltage

This curve gives the peak arc voltage, UL, which may

appear across the fuse during its operation as a function of
the applied working voltage Eg , (rms) at a power factor of

15%.

Power Losses

Watts loss at rated current is given in the electrical 
characteristics. The curve allows the calculation of the power
losses at load currents lower than the rated current. The 
correction factor, Kp, is given as a function of the RMS load

current, Ib, in % of the rated current.

Features and Benefits

• Low watts loss
• Superior cycling capability

For Other Voltage Ratings in This Body Style  

• See pages 185 (1000V) and 198 (1250V)

Size 24

Size 23

Size 24

Size 24

Size 23

Size 23

Typical Applications

• Power converters/rectifiers
• Reduced voltage starters

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

166

Square Body Flush End Contact Size 23, 24 — 660V
(IEC): 1000-7500A

-BU/55
Visual 

Indicator

Catalogue Number

Electrical Characteristics

I

2

t (A

2

Sec)

-BKE/55

Type K

Indicator

-BKN/55

Type K 

Indicator

-GU/55
Visual 

Indicator

-GKE/55

Type K

Indicator

-GKN/55

Type K 

Indicator

Watt

Loss

(W)

Rated

Voltage

(V)

Rated 

Current

RMS-Amp

Fuse
Size

Pre-arc

Clearing

at 660V

Data Sheet: 170K6326

170M6858 170M6898 170M6878 170M6918 170M6958 170M6938 

1000

79,000

530,000

170.0

170M6859 170M6899 170M6879 170M6919 170M6959 170M6939 

1100

95,000

635,000

185.0

170M6860 170M6900 170M6880 170M6920 170M6960 170M6940 

1250

155,000

1,050,000

190.0

170M6861 170M6901 170M6881 170M6921 170M6961 170M6941 

1400

200,000

1,350,000

210.0

170M6862 170M6902 170M6882 170M6922 170M6962 170M6942 

1500

240,000

1,650,000

215.0

23

170M6863 170M6903 170M6883 170M6923 170M6963 170M6943  660 

1600

315,000

2,150,000

220.0

170M6864 170M6904 170M6884 170M6924 170M6964 170M6944 

1800

450,000

3,050,000

230.0

170M6865 170M6905 170M6885 170M6925 170M6965 170M6945 

2000

625,000

4,200,000

240.0

170M6866 170M6906 170M6886 170M6926 170M6966 170M6946 

2200

805,000

5,400,000

255.0

170M6867 170M6907 170M6887 170M6927 170M6967 170M6947 

2500

1,250,000

8,350,000

265.0

170M6868 170M6908 170M6888 170M6928 170M6968 170M6948 

3000

2,250,000

15,500,000

285.0

170M6869 170M6909 170M6889 170M6929 170M6969 170M6949  600

3500

3,450,000

21,000,000

315.0

170M6870 170M6910 170M6890 170M6930 170M6970 170M6950  550

4000

5,000,000

27,500,000

340.0

170M7138 170M7158 170M7198 170M7218 

2000

340000

2300000

340

170M7139 170M7159 170M7199 170M7219 

2500

650000

4350000

390

170M7140 170M7160 170M7200 170M7220 

3000

1100000

7300000

430

170M7141 170M7161 170M7201 170M7221 

3500

1800000

12000000

460

170M7142 170M7162 170M7202 170M7222 

4000

2700000

18000000

490

24

170M7143 170M7163 170M7203 170M7223  690

4500

3800000

25500000

520

170M7144 170M7164 170M7204 170M7224 

5000

5450000

36500000

540

170M7145 170M7165 170M7205 170M7225 

5500

7400000

49500000

560

170M7146 170M7166 170M7206 170M7226 

6000

9600000

64000000

580

170M7147 170M7167 170M7207 170M7227 

6500

12500000

83000000

600

170M7148 170M7168 170M7208 170M7228 

7000

15000000

100000000

630

170M7149 170M7169 170M7209 170M7229  500

7500

18500000

93000000

660

-BU/60

without 

Indicator

Catalogue Number

Electrical Characteristics

I

2

t (A

2

Sec)

-BKN/60

Type K 

Indicator

-GU/60

without 

Indicator

-GKN/60

Type K 

Indicator

Watts

Loss

(W)

Rated

Voltage

(V)

Rated 

Current

RMS-Amp

Fuse
Size

Pre-arc

Clearing at

660V

† A

2

s @ 500V

Data Sheet: 170K6332

Catalog Numbers:

Size

24BKN

2x3 M12

24GKN

2x3 

1

/

2

” 16UNC-2B

Size 23 

Type –  BU/ 55,  - BKE/ 55,  - BKN/ 55,  - GU/ 55,  - GKE/ 55,  - GKN/ 55

Size 24

Type –  BU/ 55,  - BKE/ 55,  - BKN/ 55,  - GU/ 55,  - GKE/ 55,  - GKN/ 55

Dimensions - mm

Size

23G

2x2 M10

23B

3

/

8

” 16UNC-2B

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

167

Square Body Flush End Contact Size 23, 24 — 660V
(IEC): 1000-7500A

Size 24 — 2000-7500A: 660V

Time-Current Curve

Size 23 — 10000-4000A: 660V

Time-Current Curve

Peak Let-Through Curve

Peak Let-Through Curve

Data Sheet: Available upon request

Data Sheet: Available upon request

Prospective Current in Amps RMS

Prospective Current in Amps RMS

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

168

Square Body DIN 43 620 — 690V (IEC): 10-800A
Class gR — Full Range Fuses

690V (IEC) 10-800A

Specifications

Description:

Square body DIN 43

620 blade style high speed fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 690Vac (IEC)

Amps: — 10-800A

IR: — 300kA RMS Sym.

Agency Information:

CE, Designed and tested to  IEC

60269: Part 4. UL Recognized E125085.JFHR2.

Electrical

Characteristics

Total clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

Arc Voltage

This curve gives the
peak arc voltage, UL,

which may appear
across the fuse during
its operation as a 
function of the applied
working voltage Eg ,

(rms) at a power factor
of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Dimensions - mm

Type DIN 00, DIN 1, DIN 2, DIN 3

Size

A

B Max

D Max

E

F Min

H

00

49

78.5

60

30

35

15

1

68

135

66

52

40

20

2

68

150

74

60

48

25

3

68

150

89

75

60

32

1 mm = 0.0394” 1” = 25.4 mm

1,5

1,0

0,5

0,4

0,3

0,2

K   

Eg   

200     300     400       500      600    700

3

2,5

2

1,8

1,6

1,4

1,2

10

3

8
7
6
5

4

3

U

L

   

Eg   

200      300     400      500     600    700

1,0

0,8
0,7
0,6
0,5

0,4

0,3

0,2

0,15

0,1

K

p

   

I

b

30    40     50    60    70     80   90    100%

For Operating Class aR Fuses in This Body Style  

• See page 160

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

169

Square Body DIN 43 620 — 690V (IEC): 10-800A
Class gR — Full Range Fuses

Catalog
Numbers

Electrical Characteristics

Type T

RMS

I

2

t (A

2

Sec)

Indicator Amp

Clearing

Watts

For Micro

Size 

Rating*

Pre-arc

at 600V

Loss

170M2691

10

3.8

20

3.5

170M2692

16

7.2

38

5.5

170M2693

20

13

70

6

170M2694

25

24

125

8

170M2695

32

53

275

9

170M2696

40

95

490

10

170M2697

00

50

185

1000

11

170M2698

63

345

1800

14

170M2699

80

695

3600

16

170M2700

100

1250

6650

19

170M2701

125

2300

12000

23

170M2702

160

4350

22500

29

170M4176

50

135

705

12

170M4177

63

245

1300

15

170M4178

80

500

2600

17

170M4179

100

950

4850

20

170M4180

125

1850

9500

23

170M4181

1

160

3450

18000

28

170M4182

200

6750

34500

31

170M4183

250

13500

70500

35

170M4184

315

26000

135000

41

170M4185

350

34000

175000

45

170M4186

400

48500

250000

48

170M5881

200

5650

29000

33

170M5882

250

10000

52500

40

170M5883

315

19500

105000

46

170M5884

350

26000

135000

50

170M5885

2

400

39500

205000

53

170M5886

450

55500

290000

59

170M5887

500

73000

375000

66

170M5888

550

100000

515000

70

170M5889

630

150000

770000

79

170M6080

350

23000

120000

55

170M6081

400

34000

175000

59

170M6082

450

48500

250000

62

170M6083

500

64000

330000

67

170M6084

3

550

84500

435000

70

170M6085

630

125000

645000

85

170M6086

700

160000

840000

93

170M6087

800

245000

1300000

99

*The RMS amp rating of this fuse range is given with open fuse bases connected to copper
conductors according to IEC 60269, Part 1, table 10. When used in enclosed fuse bases/
disconnects, derating factors have to be observed.
Please contact Bussmann for application assistance.
• Watts loss provided at rated current.
• Microswitch ordered separately. See accessories on page 212-213.
• For fuse curves see pages 170 and 171.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

Catalog Numbers

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

170

Square Body, DIN 43 620 - Size 00, 1 — 690V (IEC): 
10-800A Class gR — Full Range Fuses

10

4

10

3

10

2

10

1

s

10

-1

10

-2

10

-3

10

-4

Vir

tual Pre-arcing 

Time In Seconds

Prospective Current In Amp RMS

10

10

2

10

3

10

4

16

A

2

5A

4

0A

63A

100A

160A

125A

2

0A

80A

1

0A

5

0

A

32

A

10

5

10

4

10

3

2x10

2

P

eak Let-Through Current In Amperes

Prospective Short-Circuit Current Symmetrical RMS

10

10

2

10

3

10

4

Amp

10

5

160A

125A100A

80A

63A

50A 40A
32A

25A

20A 16A
10A

10

4

10

3

10

2

10

1

s

10

-1

10

-2

10

-3

10

-4

Vir

tual Pre-arcing 

Time In Seconds

Prospective Current In Amp RMS

5x10

1

10

2

10

3

10

4

5x10

4

63A

100A

160A

250A

350A

400A

80A

3

15
A

50A

200A

125A

10

5

10

4

10

3

2x10

2

P

eak Let-Through Current In Amperes

Prospective Short-Circuit Current Symmetrical RMS

10

10

2

10

3

10

4

Amp

10

5

400A350A
315A250A

200A160A

125A100A

80A 63A

50A

Size 00 — 10-160A: 690V

Time-Current Curve

Size 1 — 50-400A: 690V

Time-Current Curve

Peak Let-Through Curve

Peak Let-Through Curve

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

171

Square Body, DIN 43 620 - Size 2, 3 — 690V (IEC): 
10-800A Class gR — Full Range Fuses

10

4

10

3

10

2

10

1

s

10

-1

10

-2

10

-3

10

-4

Vir

tual Pre-arcing 

Time In Seconds

Prospective Current In Amp RMS

10

2

10

3

10

4

10

5

200A

315A

400A

500A

630A

350A

250A

550A

450A

10

5

10

4

10

3

2x10

2

P

eak Let-Through Current In Amperes

Prospective Short-Circuit Current Symmetrical RMS

10

2

10

3

10

4

10

5

Amp

10

6

630A

550A 500A
450A 100A
350A 315A

250A 200A

10

4

10

3

10

2

10

1

s

10

-1

10

-2

10

-3

10

-4

Vir

tual Pre-arcing 

Time In Seconds

Prospective Current In Amp RMS

10

2

10

3

10

4

10

5

45

0

A

3

50

A

7

0

0A

5

50

A

800A

630A

500A

400A

10

5

10

4

10

3

2x10

2

P

eak Let-Through Current In Amperes

Prospective Short-Circuit Current Symmetrical RMS

10

2

10

3

10

4

10

5

Amp

10

6

800A

700A 630A
550A 00A
450A 400A
350A

Size 2 — 200-630A: 690V

Time-Current Curve

Size 3 — 350-800A: 690V

Time-Current Curve

Peak Let-Through Curve

Peak Let-Through Curve

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

172

1000V (IEC) 20-315A

Specifications

Description: Square body DIN 43
653 stud-mount high speed fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 1000Vac (20-250A)

— 900Vac (315A)

Amps: — 20-315A

IR: — 150kA RMS Sym.

Agency Information:

CE, Designed and tested to 

IEC 60269: Part 4. UL Recognized E125085.JFHR2.

Electrical 

Characteristics

Total clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor
of 15% are given in the 
electrical characteristics. For
other voltages, the clearing
I

2

t is found by multi-plying by

correction factor, K, given as
a function of applied working
voltage, Eg, (rms).

Square Body DIN 43 653 — 1000V (IEC): 20-315A

1,5

1,0

0,5

0,4

0,3

0,2

K   

Eg   

200 400 600  800 1000

*Rated voltage 900V

*

Arc Voltage

This curve gives the peak
arc voltage, UL, which may

appear across the fuse 
during its operation as a
function of the applied
working voltage Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

3

2,5

2

1,8

1,6

1,4

1,2

10

3

8
7
6
5

4

3

U

L

   

Eg   

200 400 600  800 1000

1,0

0,8
0,7
0,6
0,5

0,4

0,3

0,2

0,15

0,1

K

p

   

I

b

30 40 50 60 70 

80 90 

100%

Dimensions - mm

Type 00TN/80 – 00/80

Size

Max A

B

C

D

Max E

F

G

H

00/80

54

98

78

51

30

28

10

00TN/80

54

98

78

51

30

28

67

10

1mm = 0.0394” / 1” = 25.4mm

For Other Voltage Ratings in This Body Style  

• See page 145 (690V/700V)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

173

Catalog Numbers

Electrical Characteristics

00/80

00TN/80

I

2

t (A

2

Sec)

Visual

Type T

Rated

Clearing

Indicator for Indicator for

Rated

Current

at Rated Watts

Micro

Micro

Size Voltage RMS Amps

Pre-arc

Voltage

Loss

170M4802

170M4822

1000

20

20

140

5

170M4803

170M4823

1000

25

30

210

7

170M4804

170M4824

1000

32

55

390

9

170M4805

170M4825

1000

35

69

500

10

170M4806

170M4826

1000

40

100

690

11

170M4807

170M4827

1000

50

170

1200

13

170M4808

170M4828

1000

63

280

2000

18

170M4809

170M4829

00

1000

80

500

3500

22

170M4810

170M4830

1000

100

950

6850

25

170M4811

170M4831

1000

125

1500

11500

33

170M4812

170M4832

1000

160

3000

22000

37

170M4813

170M4833

1000

200

5600

40500

40

170M4814

170M4834

1000

250

10000

74000

48

170M4815

170M4835

900

315

18000

115000

58

• Watts loss provided at rated current.
• Microswitch ordered separately. See accessories on page 212-213.

Square Body DIN 43 653 — 1000V (IEC): 20-315A

10

4

 

10

10

2

 

10 

1

s

 

10

-1 

10

-2 

10

-3 

10

-4 

V

irtual Pre-arcing 

T

ime In Seconds 

Prospective Current In Amp RMS

10 10

10

10

4

 

25A 

35A 

50A 

80

A

 

125A 

20

0A 

315A

25

0A

 

63A 

4

0A 

32A

 

20A 

100A 

16

0A 

10

10

10

2

 

2x10 

Peak Let-Through Current In 

Amperes 

Prospective Short-Circuit Current symmetrical RMS 

10 10

10

10

Amp

 

10

5

 

315A 

250A 

200A

 

160A 

125A 100A 

80A  63A 
50A  40A 
35A  32A

 

25A  20A

 

Prospective Short-Circuit Current Symmetrical RMS

Size 00 — 20-315A: 1000V

Time-Current Curve

Peak Let-Through Curve

* 315A fuse is derated to 900V

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

Catalog Numbers

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

174

Square Body DIN 43 653 — 1000V (IEC): 50-1400A

1000V (IEC) 50-1400A

Specifications

Description:

Square body mount

high speed fuses.

Dimensions:

See dimensions

illustrations.

Ratings:

Volts: — 1000Vac.

Amps: — 50-1400A

IR: — 125kA RMS Sym.

Agency Information:

CE, Designed and tested to  IEC

60269: Part 4. UL Recognized E125085.JFHR2.

Electrical 

Characteristics

Total clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of the
applied working voltage
E

g

, (rms) at a power factor

of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is
given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

1,5

1,0

0,5

0,4

0,3

0,2

K   

Eg   

500  

600 

700 

800 

900  1000

*Rated voltage 900V

*

3

2,5

2

1,8

1,6

1,4

1,2

10

3

8
7
6
5

4

3

U

L

   

Eg   

500  

600 

700 

800 

900  1000

1,0

0,8
0,7
0,6
0,5

0,4

0,3

0,2

0,15

0,1

K

p

   

I

b

30 40 50 60 70 

80 90 

100%

Type-TN/110

Type-KN/110

Dimensions - mm

Type –KN/110

Size

A

B

C

Max D1 E

G

H

I

1*KN/110 80

138

108

61

43

6

22

11

1KN/110

80

138

108

69

51

6

25

11

2KN/110

80

138

108

77

59

6

25

11

3KN/110

81

139

108

92

74

6

30

11

Type –TN/110

Size

A

B

C

Max D2 E

G

H

I

1*TN/110 80

138

108

61

43

6

22

11

1TN/110

80

138

108

69

51

6

25

11

2TN/110

80

138

108

75

59

6

25

11

3TN/110

81

139

108

90

74

6

30

11

1mm = 0.0394” / 1” = 25.4mm

For Other Voltage Ratings in This Body Style  

• See pages 150 (690V/700V) and 187 (1250V/1300V)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

175

Square Body DIN 43 653 — 1000V (IEC): 50-1400A

Catalog Numbers

Electrical Characteristics

-KN/110

-TN/110

Rated

I

2

t (A

2

Sec)

Type K

Type T

Current

Clearing

Indicator for

Indicator for

Rated

RMS

at Rated

Watts

Micro

Micro

Size

Voltage

Amps

Pre-arc

Voltage

Loss

170M3965

170M3981

1000

50

135

815

20

170M3966

170M3982

1000

63

215

1300

25

170M3967

170M3983

1000

80

460

2750

30

170M3968

170M3984

1000

100

860

5100

35 

170M3969

170M3985

1000

125

1450

8600

40

170M3970

170M3986

1*

1000

160

2850

17500

45

170M3971

170M3987

1000

200

4950

29500

48

170M3972

170M3988

1000

250

9550

57000

50

170M3973

170M3989

1000

315

21500

130000

60

170M3974

170M3990

1000

350

29000

175000

65

170M3975

170M3991

1000

400

42000

250000

70

170M4965

170M4980

1000

160

2200

13500

40

170M4966

170M4981

1000

200

4150

24500

45

170M4967

170M4982

1000

250

7750

46000

52

170M4968

170M4983

1000

315

16500

98500

60

170M4969

170M4984

1

1000

350

21500

130000

65

170M4970

170M4985

1000

400

31000

185000

70

170M4971

170M4986

1000

450

44500

265000

80

170M4972

170M4987

1000

500

63000

375000

85

170M4973

170M4988

1000

550

84500

500000

90

170M4974

170M4989

1000

630

125000

755000

98

170M5966

170M5981

1000

250

6750

40000

65

170M5967

170M5982

1000

315

13500

81500

75

170M5968

170M5983

1000

350

16500

99000

80

170M5969

170M5984

1000

400

26000

155000

85

170M5970

170M5985

1000

450

35500

210000

90

170M5971

170M5986

2

1000

500

49500

295000

95

170M5972

170M5987

1000

550

66000

390000

100

170M5973

170M5988

1000

630

93500

555000

110

170M5974

170M5989

1000

700

130000

770000

115

170M5975

170M5990

1000

800

195000

1200000

125

170M8614

170M8629

1000

315

9200

54500

90

170M8615

170M8630

1000

350

13000

77500

95

170M8616

170M8631

1000

400

19000

115000

105

170M8617

170M8632

1000

450

27000

160000

107

170M8618

170M8633

1000

500

37500

225000

110

170M8619

170M8634

1000

550

52000

310000

115

170M8620

170M8635

3

1000

630

82500

490000

120

170M8621

170M8636

1000

700

115000

700000

125

170M8622

170M8637

1000

800

170000

1050000

135

170M8623

170M8638

1000

900

250000

1500000

145

170M8624

170M8639

1000

1000

340000

2050000

150

170M8625

170M8640

1000

1100

460000

2750000

155

170M8626

170M8641

1000

1250

575000

3400000

175

170M8627

170M8642

900

1400

795000

4200000

185

• Watts loss provided at rated current.
• Microswitch ordered separately. See accessories on page 212-213.
• For fuse curves see pages 180 and 181.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

Catalog Numbers

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

176

Arc Voltage

This curve gives the peak
arc voltage, UL, which may

appear across the fuse
during its operation as a
function of the applied
working voltage Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Square Body Flush End Contact — 1000V (IEC):
50–1400A

1000V (IEC) 50–1400A

Specifications

Description:

Square body flush

end contact high speed fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 1000Vac.

Amps: — 50-1400A

IR: — 150kA (Est. 300kA) RMS Sym.

Agency Information:

CE, Designed and tested to IEC

60269: Part 4. UL Recognized E125085.JFHR2.

Electrical 

Characteristics

Total clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

1,5

1,0

0,5

0,4

0,3

0,2

K   

Eg   

500  

600 

700 

800 

900  1000

*Rated voltage 900V

*

3

2,5

2

1,8

1,6

1,4

1,2

10

3

8
7
6
5

4

3

U

L

   

Eg   

500  

600 

700 

800 

900  1000

Dimensions - mm

Type –BKN/- and –GKN/-

Size

A

B

Max D E

F

F* (in)

Min G

H

1*BKN/75+GKN/75

72.5

74

61

43

M8

5

16

” – 18 UNC-2B

5

ø17.5

1BKN/75+GKN/75

73.2

74

69

52

M8

5

16

” – 18 UNC-2B

8

ø20

2BKN/75+GKN/75

73.2

74.4

77

59

M10

3

8

” – 16 UNC-2B

10

ø24

3BKN/75+GKN/75

73.3

75.4

92

74

M12

1

2

” – 13 UNC-2B

10

ø30

3BKN/90+GKN/90

80.3

91.4

92

74

M12

1

2

” – 13 UNC-2B

10

ø30

* Valid for fuses type –GKN/-.
1mm = 0.0394” / 1” = 25.4mm

1,0

0,8
0,7
0,6
0,5

0,4

0,3

0,2

0,15

0,1

K

p

   

I

b

30 40 50 60 70 

80 90 

100%

For Other Voltage Ratings in This Body Style  

• See pages 152 (690V/700V) and 189 (1250V/1300V)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

177

Square Body Flush End Contact — 1000V (IEC):
50–1400A

Catalog Numbers

Electrical Characteristics

-BKN/-

-GKN/-

I

2

t (A

2

Sec) 

Type K

Type K

Rated

Clearing

Indicator for Indicator for

Rated

Current

at Rated

Watts

Micro

Micro

Size

Voltage

RMS-Amps

Pre-arc

Voltage

Loss

170M3951

170M3921

1000

50

135

815

20

170M3952

170M3922

1000

63

215

1300

25

170M3953

170M3923

1000

80

460

2750

30

170M3954

170M3924

1000

100

860

5100

35

170M3955

170M3925

1000

125

1450

8600

40

170M3956

170M3926

1*

1000

160

2850

17500

45

170M3957

170M3927

1000

200

4950

29500

48

170M3958

170M3928

1000

250

9550

57000

50

170M3959

170M3929

1000

315

21500

130000

60

170M3960

170M3930

1000

350

29000

175000

65

170M3961

170M3931

1000

400

42000

250000

70

170M4951

170M4921

1000

160

2200

13500

40

170M4952

170M4922

1000

200

4150

24500

45

170M4953

170M4923

1000

250

7750

46000

52

170M4954

170M4924

1000

315

16500

98500

60

170M4955

170M4925

1

1000

350

21500

130000

65

170M4956

170M4926

1000

400

31000

185000

70

170M4957

170M4927

1000

450

44500

265000

80

170M4958

170M4928

1000

500

63000

375000

85

170M4959

170M4929

1000

550

84500

500000

90

170M4960

170M4930

1000

630

125000

755000

98

170M5952

170M5922

1000

250

6750

40000

65

170M5953

170M5923

1000

315

13500

81500

75

170M5954

170M5924

1000

350

16500

99000

80

170M5955

170M5925

1000

400

26000

155000

85

170M5956

170M5926

1000

450

35500

210000

90

170M5957

170M5927

2

1000

500

49500

295000

95

170M5958

170M5928

1000

550

66000

390000

100

170M5959

170M5929

1000

630

93500

555000

110

170M5960

170M5930

1000

700

130000

770000

115

170M5961

170M5931

1000

800

195000

1200000

125

170M8600

170M8500

1000

315

9200

54500

90

170M8601

170M8501

1000

350

13000

77500

95

170M8602

170M8502

1000

400

19000

115000

105

170M8603

170M8503

1000

450

27000

160000

107

170M8604

170M8504

1000

500

37500

225000

110

170M8605

170M8505

1000

550

52000

310000

115

170M8606

170M8506

3

1000

630

82500

490000

120

170M8607

170M8507

1000

700

115000

700000

125

170M8608

170M8508

1000

800

170000

1050000

135

170M8609

170M8509

1000

900

250000

1500000

145

170M8610

170M8510

1000

1000

340000

2050000

150

170M8611

170M8511

1000

1100

460000

2750000

155

170M8612** 170M8512**

1000

1250

575000

3400000

175

170M8613** 170M8513**

900

1400

795000

4200000

185

**Overall length is 90mm, for all other fuses the overall length is 75mm.
• Watts loss provided at rated current.
• Microswitch ordered separately. See accessories on page 212-213.
• For fuse curves see pages 180 and 181.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

Catalog Numbers

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

178

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of the applied
working voltage Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Square Body US style — 1000V (IEC): 50-1400A

1000V (IEC) 50-1400A

Specifications

Description:

Square body US

style high speed fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts:

— 1000Vac.

Amps:

— 50-1400A

IR:

— 150kA RMS Sym.

Agency Information:

CE, Designed and tested to  IEC

60269: Part 4. UL Recognized E125085.JFHR2.

Electrical 

Characteristics

Total clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor
of 15% are given in the
electrical characteristics. For
other voltages, the clearing
I

2

t is found by multiplying by

correction factor, K, given as
a function of applied 
working voltage, Eg, (rms).

1,5

1,0

0,5

0,4

0,3

0,2

K   

Eg   

500  

600 

700 

800 

900  1000

*Rated voltage 900V

*

3

2,5

2

1,8

1,6

1,4

1,2

10

3

8
7
6
5

4

3

U

L

   

Eg   

500  

600 

700 

800 

900  1000

1,0

0,8
0,7
0,6
0,5

0,4

0,3

0,2

0,15

0,1

K

p

   

I

b

30 40 50 60 70 

80 90 

100%

Dimensions - mm

Type –FKE/115

Size

B

C1

C2

D

E

H

I

1*FKE/115

156

130

101

59

45

20

10

1FKE/115

160

127

102

69

53

25

14

2FKE/115

160

127

102

77

61

25

14

3FKE/115

159

128

101

92

76

36

16

1mm = 0.0394” / 1” = 25.4mm

For Other Voltage Ratings in This Body Style  

• See pages 154 (690V/700V) and 191 (1250V/1300)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

179

Square Body US style — 1000V (IEC): 50-1400A

Catalog Numbers

-FKE/115

Electrical Characteristics

Type K

Rated

I

2

t (A

2

Sec)

Indicator for

Current

Clearing

Watts

Micro

Size

RMS-Amps

Pre-arc

at 1000V

Loss

170M3531

50

135

815

20

170M3532

63

215

1300

25

170M3533

80

460

2750

30

170M3534

100

860

5100

35

170M3535

125

1450

8600

40

170M3536

1*

160

2850

17500

45

170M3537

200

4950

29500

48

170M3538

250

9550

57000

50

170M3539

315

21500

130000

60

170M3540

350

29000

175000

65

170M3541

400

42000

250000

70

170M4531

160

2200

13500

40

170M4532

200

4150

24500

45

170M4533

250

7750

46000

52

170M4534

315

16500

98500

60

170M4535

350

21500

130000

65

170M4536

1

400

31000

185000

70

170M4537

450

44500

265000

80

170M4538

500

63000

375000

85

170M4539

550

84500

500000

90

170M4540

630

125000

755000

98

170M5531

250

6750

40000

65

170M5532

315

13500

81500

75

170M5533

350

16500

99000

80

170M5534

400

26000

155000

85

170M5535

450

35500

210000

90

170M5536

2

500

49500

295000

95

170M5537

550

66000

390000

100

170M5538

630

93500

555000

110

170M5539

700

130000

770000

115

170M5540

800

195000

1200000

125

170M8531

315

9200

54500

90

170M8532

350

13000

77500

95

170M8533

400

19000

115000

105

170M8534

450

27000

160000

107

170M8535

500

37500

225000

110

170M8536

550

52000

310000

115

170M8537

3

630

82500

490000

120

170M8538

700

115000

700000

125

170M8539

800

170000

1050000

135

170M8540

900

250000

1500000

145

170M8541

1000

340000

2050000

150

170M8542

1100

460000

2750000

155

170M8543

1250

575000

3400000

175

170M8544*

1400

795000

4200000*

185

* Rated voltage 900V.
• Watts loss provided at rated current.
• Microswitch ordered separately. See accessories on pages 212-213.
• For fuse curves see pages 180 and 181.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

Catalog Numbers

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

180

Square Body, US style - Size 1*, 1 — 1000V (IEC): 
50-1400A

1s 

10

-1 

10

-2

 

10

-3 

10

-4 

V

irtual Pre-arcing 

T

ime In Seconds 

Prospective Current In Amp RMS

5x10

10

2

 10

10

5x10

4

 

50A 

80A 

1

25A 

200A 

315

400A 

350A 

63A 

160A 

2

50A 

100A 

10

5

 

10

10

3

 

2x10

Peak Let-Through Current In 

Amperes 

Prospective Short-Circuit Current Symmetrical RMS

10

2

 10

10

10

Amp

 

10

6

 

400A

 

350A

 

315A

 

250A

 

200A 

160A 

50A

 

630A

 

80A

 

100A 

125A 

Size 1* — 50-400A: 1000V

Time-Current Curve

Peak Let-Through Curve

10

4

 

10

10

2

 

10 

1

s

 

10

-1 

10

-2 

10

-3 

10

-4 

V

irtual Pre-arcing 

T

ime In Seconds 

Prospective Current In Amp RMS

10

2

 10

10

10

5

 

200A 

315A

 

400A 

500A 

630A 

16

0A 

35

0A 

25

0A 

450A 

5

50A 

10

5

 

10

10

3

 

2x10

Peak Let-Through Current In 

Amperes 

Prospective Short-Circuit Current Symmetrical RMS

10

2

 10

10

10

Amp

 

10

6

 

550A 

500A

 

450A 

400A

 350A 

315A 

630A

 

160A

 

200A

 

250A

 

Size 1 — 160-630A: 1000V

Time-Current Curve

Peak Let-Through Curve

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

181

Square Body, US style - Size 2, 3 — 1000V (IEC): 
50-1400A

Size 2 — 250-800A: 1000V

Time-Current Curve

Peak Let-Through Curve

10

4

 

10

10

2

 

10 

1

s

 

10

-1 

10

-2 

10

-3 

10

-4 

V

irtual Pre-arcing 

T

ime In Seconds 

Prospective Current In Amp RMS

10

2

 10

10

10

5

 

250A 

350A 

550A  70

0A 

315A 

500A 

400

630A 

800A 

450A 

10

5

 

10

10

3

 

2x10

Peak Let-Through Current In 

Amperes 

Prospective Short-Circuit Current Symmetrical RMS

10

2

 10

10

10

Amp

 

10

6

 

700A

 

800A 

630A 
500A 

550A 

450A

 

250A

 

315A

 

350A 

400A 

10

4

 

10

10

2

 

10 

1

s

 

10

-1 

10

-2 

10

-3 

10

-4 

V

irtual Pre-arcing 

T

ime In Seconds 

Prospective Current In Amp RMS

10

2

 10

10

10

5

 

350A 

450A 

700A 

900A 

315A 

500A 

40

0A 

630A 

800A 

550A 

1100A  1400A* 

1000A  1250A 

10

5

 

10

10

3

 

2x10

Peak Let-Through Current In 

Amperes 

Prospective Short-Circuit Current Symmetrical RMS

10

2

 10

10

10

Amp

 

10

6

 

1250A

 

1400A

1100A 
900A 

1000A 

800A 

500A 

550A

 

630A 

700A 

450A  400A 
350A

  315A

 

Size 3 — 315-1400A: 1000V

Time-Current Curve

Peak Let-Through Curve

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

182

Square Body Flush End Contact Size 4 — 1000V (IEC):
1000-2700A

1000V (IEC) 1000-2700A

Specifications

Description:

Square body DIN

43 620 blade style high speed
fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 1000Vac (IEC)

Amps: — 1000-2700A

IR: — 125kA RMS Sym.

Agency Information:

CE, Designed and tested to  IEC

60269: Part 4. UL Recognized E125085.JFHR2.

Electrical 

Characteristics

Total clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

Arc Voltage

This curve gives the
peak arc voltage, UL,

which may appear
across the fuse during
its operation as a 
function of the applied
working voltage Eg ,

(rms) at a power factor
of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

For Other Voltage Ratings in This Body Style  

• See pages 163 (690V/700V) and 195 (1250V)

-BKN/95

Type K

Indicator

Catalog Number

Electrical Characteristics

I

2

t (A

2

Sec)

-SBKN/90

Type K

Indicator

Watt

Loss

(W)

Rated 

Voltage

(V)

Rated

Current

RMS-Amp

Fuse

Size

Pre-arc

Clearing

at 1000V

— 170M7542 

1000

180000

1100000

195

170M7031 1100

250000

1500000

200

170M7636 170M7548 

1500

600000

3600000

250

170M7639 170M7034 

1700

850000

5000000

260

4

170M7963 170M7544 

1000

2000

1450000

8600000

270

170M7090

170M7035 2200

2000000

12000000

280

170M7640 170M7036 

2500

3000000

18000000

295

170M7658

170M7037 2700

3700000

22000000

310

Catalog Numbers

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

183

Square Body Flush End Contact Size 4 — 1000V (IEC):
1000-2700A

Dimensions - mm 

Type 4BKN/ 95

Type 4SBKN/ 95

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

184

Square Body Flush End Contact Size 4 — 1000V (IEC):
1000-2700A

Size 4 — 1000-2700A: 660V

Time-Current Curve

Peak Let-Through Curve

Data Sheet: Available upon request

Prospective Current in Amps RMS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

185

Square Body Flush End Contact Size 24 — 1000V (IEC):
2000-5000A

Arc Voltage

This curve gives the peak arc voltage, UL, which may

appear across the fuse during its operation as a function of
the applied working voltage Eg , (rms) at a power factor of

15%.

Power Losses

Watts loss at rated current is given in the electrical 
characteristics. The curve allows the calculation of the power
losses at load currents lower than the rated current. The 
correction factor, Kp, is given as a function of the RMS load

current, Ib, in % of the rated current.

Features and Benefits

• Low watts loss
• Superior cycling capability

For Other Voltage Ratings in This Body Style  

• See pages 165 (660V) and 198 (1250V)

4200-5000A

4200-5000A

2000-3500A

2000-3500A

Typical Applications

• Power converters/rectifiers
• Reduced voltage starters

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

Catalog Numbers

170M7608 2000

885000

5700000

345

170M7680 3000

2900000

19000000

430

170M7567 3200

3300000

20000000 

440 

24

170M7568 1000

3500

4500000

27000000

450

170M7569 4000

6800000

40000000 

475 

170M7498 4200

8000000

47500000

485

170M7488 4500

10000000

59000000

495

170M7622 5000

14000000

82500000

540

-BKN/85

Type K

Indicator

Cat. Number

Electrical Characteristics

I

2

t (A

2

Sec)

Watt

Loss

(W)

Rated

Voltage

(V)

Rated

Current

RMS-Amp

Fuse

Size

Pre-arc

Clearing at

1000V

Data Sheet: 170K7540, 170K8514

Dimensions - mm

High Speed Fuses

1000V (IEC) 2000-5000A

Specifications

Description:

High speed square

body fuses, for the protection of 
the power rectifier section of the
equipment.

Dimensions:

See dimensions 

illustration.

Ratings:

Volts: — 1000Vac

Amps: — 2000-5000A

IR: — 300kA RMS Sym.

Agency Information:

CE, Designed and tested to IEC

60269: Part 4. UL Recognized E125085.JFHR2.

Electrical Characteristics

Total clearing I

2

t

The total clearing I

2

t at rated voltage and at power factor of

15% are given in the electrical characteristics. For other 
voltages, the clearing I

2

t is found by multiplying by correction

factor, K, given as a function of applied working voltage, 
Eg, (rms).

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body Flush End Contact Size 24 — 1000V (IEC):
2000-5000A

Size 24 — 4200-5000A: 1000V

Time-Current Curve

Size 24 — 2000-3500A: 1000V

Time-Current Curve

Peak Let-Through Curve

Peak Let-Through Curve

Data Sheet: Available upon request

Data Sheet: Available upon request

Prospective Current in Amps RMS

Prospective Current in Amps RMS

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

186

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

187

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Square Body DIN 43 653 — 1250V/1300V (IEC/UL): 
50-1400A

1250V/1300V (IEC/UL)  50-1400A

Specifications

Description:

Square body DIN

43 653 stud-mount high speed
fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 1250Vac (IEC)

— 1300Vac (UL)

Amps: — 50-1400A

IR: — 100kA RMS Sym.

Agency Information:

CE, Designed and tested to  IEC

60269: Part 4. UL Recognized E125085.JFHR2, CSA
Certified: Class 53787, File 1422-30.

Electrical 

Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at
power factor of 15% are
given in the electrical
characteristics. For other
voltages, the clearing I

2

t

is found by multiplying by
correction factor, K,
given as a function of
applied working voltage,
Eg, (rms).

UL

3

2.5

8

10

3

1.4

1.8

6

4

5

3

400

600

800

1000 1200 1400

E

g

Dashed lines (- - - - - -) apply to the following
amperages:.
Size

Amps.

1*

400A

1

500-630A

2

630-1000A

3

800-1400A

K

1.5

1.0

1.25

0.5

0.4

0.3

0.2

400

600

800

1000 1200

1400

E

g

K

p

30 40 50

60

70

80 90 100%

I

b

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

A

B

108

D

E

E

6

H

11

Dimensions - mm

Type -/110, -TN/110

Size A

B

D** E

H

1*

80

138

58

45

20

1

80

138

66

53

25

2

80

138

75

61

25

3

81

139

90

76

30

**Microswitch.
1mm = 0.0394” / 1” = 25.4mm

For Other Voltage Ratings in This Body Style  

• See pages 150 (690V/700V) and 176 (1000V)

C

B

A

H

11

6

E

E

D

Type -KN/110

Size

A

B

D

E

H

1*

80

138

58

45

20

1

80

138

66

53

25

2

80

138

75

61

25

3

81

139

90

76

30

1mm = 0.0394” / 1” = 25.4mm

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body DIN 43 653 — 1250V/1300V (IEC/UL): 
50-1400A

Catalog Numbers

-TN/110

-KN/110

Electrical Characteristics

-/110

Type T

Type K

Rated

I

2

t (A

2

Sec)

Visual

Indicator

Indicator

Current

Clearing

Clearing

Watts

Indicator

for Micro

for Micro

Size

RMS-Amps

Pre-arc

at 1000V

at 1250V

Loss

170M3138

170M3188

170M3238

50

135

815

1100

15

170M3139

170M3189

170M3239

63

215

1300

1750

20

170M3140

170M3190

170M3240

80

420

2500

3350

25

170M3141

170M3191

170M3241

100

750

4450

5950

30

170M3142

170M3192

170M3242

125

1450

9000

11500

35

170M3143

170M3193

170M3243

1*

160

2600

16000

21000

40

170M3144

170M3194

170M3244

200

5150

31000

41000

45

170M3145

170M3195

170M3245

250

9200

54500

73000

55

170M3146

170M3196

170M3246

315

18500

115000

150000

60

170M3147

170M3197

170M3247

350

27000

165000

220000

65

170M3148

170M3198

170M3248

400

53000

265000

335000

70

170M4138

170M4188

170M4238

160

1900

11500

15500

45

170M4139

170M4189

170M4239

200

3800

22500

30000

50

170M4140

170M4190

170M4240

250

7750

46000

61500

60

170M4141

170M4191

170M4241

315

15000

90000

120000

65

170M4142

170M4192

170M4242

1

350

20000

125000

165000

70

170M4143

170M4193

170M4243

400

29500

175000

235000

75

170M4144

170M4194

170M4244

450

42000

250000

335000

80

170M4145

170M4195

170M4245

500

69500

340000

435000

85

170M4146

170M4196

170M4246

550

95000

465000

590000

95

170M4147

170M4197

170M4247

630†

130000

660000

100

170M5138

170M5188

170M5238

250

6500

38500

51500

65

170M5139

170M5189

170M5239

280

9350

55500

74500

70

170M5140

170M5190

170M5240

315

13000

77500

105000

75

170M5141

170M5191

170M5241

350

16500

97500

135000

80

170M5142

170M5192

170M5242

400

23000

140000

180000

85

170M5143

170M5193

170M5243

450

34000

205000

270000

90

170M5144

170M5194

170M5244

2

500

48000

285000

380000

95

170M5145

170M5195

170M5245

550

62000

370000

495000

100

170M5146

170M5196

170M5246

630

115000

575000

730000

110

170M5147

170M5197

170M5247

700

160000

795000

1050000

115

170M5148

170M5198

170M5248

800

245000

1200000

1550000

120

170M5149

170M5199

170M5249

900†

360000

1750000

125

170M5150

170M5200

170M5250

1000†

480000

2350000

135

170M6138

170M6188

170M6238

315

9500

58000

77500

85

170M6139

170M6189

170M6239

350

13500

81500

110000

90

170M6140

170M6190

170M6240

400

19500

120000

160000

95

170M6141

170M6191

170M6241

450

31000

185000

245000

100

170M6142

170M6192

170M6242

500

39000

235000

310000

105

170M6143

170M6193

170M6243

550

55000

325000

435000

110

170M6144

170M6194

170M6244

3

630

83500

495000

665000

115

170M6145

170M6195

170M6245

700

115000

705000

940000

120

170M6146

170M6196

170M6246

800‡

205000

995000

1300000

125

170M6147

170M6197

170M6247

900‡

305000

1500000

1900000

130

170M6148

170M6198

170M6248

1000‡

450000

2150000

2750000

135

170M6149

170M6199

170M6249

1100‡

575000

2800000

3600000

140

170M6150

170M6200

170M6250

1250†

810000

3950000

145

170M6151

170M6201

170M6251

1400†

1250000

6000000

150

†Rated voltage (IEC) 1100V.
‡Rated voltage (IEC) 1250V.
• Watts loss provided at rated current.
• Microswitch indicator ordered separately. See accessories on pages 212-213.
• For fuse curves see pages 193 and 194.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

188

Catalog Numbers

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

189

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Square Body Flush End Contact — 1250V/1300V (IEC/UL):
50-1400A

1250V/1300V (IEC/UL)  50-1400A

Specifications

Description:

Square body flush

end contact high speed fuses.

Dimensions:

See dimensions

illustrations.

Ratings:

Volts: — 1250Vac (IEC)

— 1300Vac (UL)

Amps: — 50-1400A

IR: — 100kA RMS Sym.

Agency Information:

CE, Designed and tested to IEC

60269: Part 4. UL Recognized E125085.JFHR2, CSA
Certified: Class 53787, File 1422-30.

Electrical 

Characteristics

Total Clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor
of 15% are given in the 
electrical characteristics. For
other voltages, the clearing
I

2

t is found by multiplying by

correction factor, K, given as
a function of applied working
voltage, Eg, (rms).

A

B

D

E

E

H

G

F

Dimensions - mm

Type -BKN/-, -GKN/-

Size Type

A

B

D

E

F

F** (in)

G

H

1*

BKN + GKN/75

74

75

59

45

M8

5

16

” - 18 UNC-2B

5

Ø17

1*

BKN/80

80

81

59

45

M8

5

Ø17

1

BKN + GKN/75

74

75

69

53

M8

5

16

” - 18 UNC-2B

8

Ø20

1

BKN/80

80

81

69

53

M8

8

Ø20

2

BKN + GKN/75

74

75

77

61

M10

3

8

” - 16 UNC-2B

10

Ø24

2

BKN/80

80

81

77

61

M10

10

Ø24

2

BKN + GKN/90

80

91

77

61

M10

3

8

” - 16 UNC-2B

10

Ø24

3

BKN + GKN/75

74

76

92

76

M12

1

2

” - 13 UNC-2B

10

Ø30

3

BKN/80

81

83

92

76

M12

10

Ø30

3

BKN + GKN/90

81

91

92

76

M12

1

2

” - 13 UNC-2B

10

Ø30

**Valid for fuses type -GKN/-.
1mm = 0.0394” / 1” = 25.4mm

K

1.5

1.0

1.25

0.5

0.4

0.3

0.2

400

600

800

1000 1200

1400

E

g

UL

3

2.5

8

10

3

1.4

1.8

6

4

5

3

400

600

800

1000 1200 1400

E

g

K

p

30 40 50

60

70

80 90 100%

I

b

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

Dashed lines (- - - - - -) apply to the
following amperages:.

Size

Amps.

1*

400A

1

500-630A

2

630-1000A

3

800-1400A

For Other Voltage Ratings in This Body Style  

• See pages 152 (690V/700V) and 176 (1000V)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body Flush End Contact — 1250V/1300V (IEC/UL):
50-1400A

Catalog Numbers

Electrical Characteristics

-BKN/75

-BKN/80

-BKN/90

-GKN/75

-GKN/90

Rated

Type K

Type K

Type K

Type K

Type K

Current

I

2

t (A

2

Sec)

Indicator

Indicator

Indicator

Indicator

Indicator

RMS-

Clearing

Clearing

Watts

for Micro

for Micro

for Micro

for Micro

for Micro

Size Amps

Pre-arc

at 1000V

at 1250V

Loss

170M3388

170M3438

170M3488

50

135

815

1100

15

170M3389

170M3439

170M3489

63

215

1300

1750

20

170M3390

170M3440

170M3490

80

420

2500

3350

25

170M3391

170M3441

170M3491

100

750

4450

5950

30

170M3392

170M3442

170M3492

125

1450

9000

11500

35

170M3393

170M3443

170M3493

1*

160

2600

16000

21000

40

170M3394

170M3444

170M3494

200

5150

31000

41000

45

170M3395

170M3445

170M3495

250

9200

54500

73000

55

170M3396

170M3446

170M3496

315

18500

115000

150000

60

170M3397

170M3447

170M3497

350

27000

165000

220000

65

170M3448

400

53000

265000

335000

70

170M4388

170M4438

170M4488

160

1900

11500

15500

45

170M4389

170M4439

170M4489

200

3800

22500

30000

50

170M4390

170M4440

170M4490

250

7750

46000

61500

60

170M4391

170M4441

170M4491

315

15000

90000

120000

65

170M4392

170M4442

170M4492

350

20000

125000

165000

70

170M4393

170M4443

170M4493

1

400

29500

175000

235000

75

170M4394

170M4444

170M4494

450

42000

250000

335000

80

170M4395† 170M4445

170M4495†

500

69500

340000

435000

85

170M4396‡ 170M4446

170M4496‡

550

95000

465000

590000

95

170M4397‡ 170M4447†

170M4497‡

630

130000

660000

100

170M5388

170M5438

170M5588

250

6500

38500

51500

65

170M5389

170M5439

170M5589

280

9350

55500

74500

70

170M5390

170M5440

170M5590

315

13000

77500

105000

75

170M5391

170M5441

170M5591

350

16500

97500

135000

80

170M5392

170M5442

170M5592

400

23000

140000

180000

85

170M5393

170M5443

170M5593

450

34000

205000

270000

90

170M5394

170M5444

170M5494

170M5594

170M5644

2

500

48000

285000

380000

95

170M5395

170M5445

170M5495

170M5595

170M5645

550

62000

370000

495000

100

170M5396† 170M5446

170M5496

170M5596†

170M5646

630

115000

575000

730000

110

170M5397‡ 170M5447†

170M5497

170M5597‡

170M5647

700

160000

795000

1050000

115

170M5398‡ 170M5448‡

170M5498

170M5598‡

170M5648

800

245000

1200000

1550000

120

170M5499

170M5649

900†

360000

1750000

125

170M5500

170M5650

1000†

480000

2350000

135

170M6338

170M6538

170M6588

315

9500

58000

77500

85

170M6339

170M6539

170M6589

350

13500

81500

110000

90

170M6340

170M6540

170M6590

400

19500

120000

160000

95

170M6341

170M6541

170M6591

450

31000

185000

245000

100

170M6342

170M6542

170M6592

500

39000

235000

310000

105

170M6343

170M6543

170M6593

550

55000

325000

435000

110

170M6344

170M6544

170M6494

170M6594

170M6644

630

83500

495000

665000

115

170M6345

170M6545

170M6495

170M6595

170M6645

3

700

115000

705000

940000

120

170M6346† 170M6546

170M6496¥

170M6596†

170M6646¥

800

205000

995000

1300000

125

170M6347‡ 170M6547†

170M6497¥

170M6597‡

170M6647¥

900

305000

1500000

1900000

130

170M6348‡ 170M6548†

170M6498¥

170M6598‡

170M6648¥

1000

450000

2150000

2750000

135

170M6349‡ 170M6549‡

170M6499¥

170M6599‡

170M6649¥

1100

575000

2800000

3600000

140

170M6500

170M6650

1250†

810000

3950000

145

170M6501

170M6651

1400†

1250000

6000000

150

†Rated voltage (IEC) 1100V.
‡Rated voltage (IEC) 1000V.
¥Rated voltage (IEC) 1250V.
• Watts loss provided at rated current.
• Microswitch indicator ordered separately. See accessories on pages 212-213.
• For fuse curves see pages 193 and 194.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

190

Catalog Numbers

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

191

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Square Body US Style — 1250V/1300V (IEC/UL):  50-1400A

1250V/1300V (IEC/UL)  50-1400A

Specifications

Description:

Square body US

style high speed fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 1250Vac (IEC)

— 1300Vac (UL)

Amps: — 50-1400A

IR: — 100kA RMS Sym.

Agency Information:

CE,

Designed and tested to  IEC
60269: Part 4. UL Recognized
E125085.JFHR2, CSA Certified:
Class 53787, File 1422-30.

Electrical 

Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given as
a function of applied working
voltage, Eg, (rms).

B

C2

D

E

E

6

I

C1

A

Dimensions - mm

Type -FU/115, -FKE/115

Size

B

C1

C2

D

E

H

I

1*

156

130

101

59

45

20

10

1

160

127

102

69

53

25

14

2

160

127

102

77

61

25

14

3

159

128

101

92

76

36

16

1mm = 0.0394” / 1” = 25.4mm

K

1.5

1.0

1.25

0.5

0.4

0.3

0.2

400

600

800

1000 1200

1400

E

g

UL

3

2.5

8

10

3

1.4

1.8

6

4

5

3

400

600

800

1000 1200 1400

E

g

K

p

30 40 50

60

70

80 90 100%

I

b

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

Dashed lines (- - - - - -) apply to the
following amperages:.

Size

Amps.

1*

400A

1

500-630A

2

630-1000A

3

800-1400A

For Other Voltage Ratings in This Body Style  

• See pages 153 (690V/700V) and 178 (1000V)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body US Style — 1250V/1300V (IEC/UL):  50-1400A

Catalog Numbers

-FKE/115

Electrical Characteristics

-FU/115

Type K

Rated

I

2

t (A

2

Sec)

Without

Indicator

Current

Clearing

Clearing

Watts

Indicator

for Micro

Size

RMS-Amps

Pre-arc

at 1000V

at 1250V

Loss

170M3688

170M3738

50

135

815

1100

15

170M3689

170M3739

63

215

1300

1750

20

170M3690

170M3740

80

420

2500

3350

25

170M3691

170M3741

100

750

4450

5950

30

170M3692

170M3742

125

1450

9000

11500

35

170M3693

170M3743

1*

160

2600

16000

21000

40

170M3694

170M3744

200

5150

31000

41000

45

170M3695

170M3745

250

9200

54500

73000

55

170M3696

170M3746

315

18500

115000

150000

60

170M3697

170M3747

350

27000

165000

220000

65

170M4688

170M4738

160

1900

11500

15500

45

170M4689

170M4739

200

3800

22500

30000

50

170M4690

170M4740

250

7750

46000

61500

60

170M4691

170M4741

315

15000

90000

120000

65

170M4692

170M4742

1

350

20000

125000

165000

70

170M4693

170M4743

400

29500

175000

235000

75

170M4694

170M4744

450

42000

250000

335000

80

170M4695

170M4745

500†

69500

340000

85

170M4696

170M4746

550†

95000

465000

95

170M4697

170M4747

630‡

130000

660000

100

170M5688

170M5738

250

6500

38500

51500

65

170M5689

170M5739

280

9350

55500

74500

70

170M5690

170M5740

315

13000

77500

105000

75

170M5691

170M5741

350

16500

97500

135000

80

170M5692

170M5742

400

23000

140000

180000

85

170M5693

170M5743

450

34000

205000

270000

90

170M5694

170M5744

2

500

48000

285000

380000

95

170M5695

170M5745

550

62000

370000

495000

100

170M5696

170M5746

630

115000

575000

730000

110

170M5697

170M5747

700†

160000

795000

115

170M5698

170M5748

800†

245000

1200000

120

170M5699

170M5749

900‡

360000

1750000

125

170M5700

170M5750

1000‡

480000

2350000

135

170M6688

170M6738

315

9500

58000

77500

185

170M6689

170M6739

350

13500

81500

110000

90

170M6690

170M6740

400

19500

120000

160000

95

170M6691

170M6741

450

31000

185000

245000

100

170M6692

170M6742

500

39000

235000

310000

105

170M6693

170M6743

550

55000

325000

435000

110

170M6694

170M6744

3

630

83500

495000

665000

115

170M6695

170M6745

700

115000

705000

940000

120

170M6696

170M6746

800

205000

995000

1300000

125

170M6697

170M6747

900

305000

1500000

1900000

130

170M6698† 170M6748†

1000¥

450000

2150000

135

170M6699† 170M6749†

1100¥

575000

2800000

140

170M6700‡ 170M6750‡

1250¥

810000

3950000

145

170M6701‡ 170M6751‡

1400¥

1250000

6000000

150

†Rated voltage (IEC) 1100.
‡Rated voltage (IEC) 1000V.
¥ UL Recognition at 1000V.
• Watts loss provided at rated current.
• Microswitch indicator ordered separately. See accessories on pages 212-213.
• For fuse curves see pages 193 and 194.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

192

Catalog Numbers

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

193

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Square Body Size 1*, 1 — 1250V/1300V (IEC/UL): 
50-1400A

Size 1* — 50-400A:1250V

Time-Current Curve

1x10

2

10

3

10

4

10

5

10

6

2x10

2

10

3

10

4

10

5

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current 

50A

63A

80A

100A

125A

160A

200A

250A

315A

350A

400A

A

B

1

Peak Let-Through Curve

1x10

10

10

10

1x10

–4 

10

–3 

10

–2 

10

–1 

10

10

10

10

10

Prospective Current In Amp RMS

V

irtual Pre-Arcing 

T

ime In Seconds 

160A

 

200A

 

250A

 

315A

  350A

 

400A

  450A

 

500A

  550A

 

630A

 

 

 

Size 1 — 160-630A: 1250V

Time-Current Curve

1x10

2

10

3

10

4

10

5

10

6

2x10

2

10

3

10

4

10

5

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through In Amperes

160A

200A

250A

315A

350A

400A

450A

500A

550A

630A

A

B

Peak Let-Through Curve

630A fuse is derated to 1100V (IEC).

Data Sheet: 17056630

Data Sheet: 17056632

Square Body Size 1*, 1 — 1250V/1300V (IEC/UL): 
50-1400A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body Size 2, 3 — 1250V/1300V (IEC/UL): 
50-1400A

1x10

10

10

10

5

1x10

–4 

10

–3 

10

–2 

10

–1 

10

10

10

10

10

Prospective Current In Amp RMS

V

irtual Pre-Arcing 

T

ime In Seconds 

250A

 

280A

 

315A

 

350A

 

400A

 

450A

 

500A

 

550A

 

630A

 

700A

 

800A

 

900A

 

1000A

 

Size 2 — 250-1000A: 1250V

Time-Current Curve

1x10

2

10

3

10

4

   10

10

6

2x10

2

10

3

10

4

10

5

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

250A

280A

315A

350A

400A

450A

500A

550A

630A

700A

800A

900A

1000A

A

B

Peak Let-Through Curve

900-1000A fuses are derated to 1100V (IEC).

Size 3 — 315-1400A: 1250V

Time-Current Curve

Peak Let-Through Curve

1250-1400A fuses are derated to 1100V (IEC).

Data Sheet: 17056634

Data Sheet: 17056636

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

194

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

195

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Square Body Flush End Contact Size 4 — 1250V (IEC):
1400-2500A

1250V (IEC) 1400-2500A

Specifications

Description:

High speed

square body fuses, for the 
protection of the power rectifier
section of the equipment.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 1250Vac (IEC)

Amps: — 1400-2500A

IR: — 125kA RMS Sym.

Agency Information:

CE, Designed and tested to IEC

60269: Part 4. UL Recognized E125085.JFHR2.

Electrical 

Characteristics

Total clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

Arc Voltage

This curve gives the
peak arc voltage, UL,

which may appear
across the fuse during
its operation as a 
function of the applied
working voltage Eg ,

(rms) at a power factor
of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

For Other Voltage Ratings in This Body Style  

• See pages 163 (690V/700V) and 182 (1000V)

-BKN/105

Type K

Indicator

Catalog Number

Electrical Characteristics

I

2

t (A

2

Sec)

-SBKN/105

Type K

Indicator

Watt

Loss

(W)

Rated

Voltage

(V)

Rated

Current

RMS-Amp

Fuse

Size

Pre-arc

Clearing

at 1250V

Data Sheet: 170K6640 , 170K6642

170M7217 170M7512 

1400

800000

5000000

195

170M7597

170M7510 1500

1000000

6200000

200

170M7676 170M7511 

1700

1400000

8700000

220

4

170M7532 170M7976 

1250

1800

1700000

11000000

225

170M7633 170M7513 

2000

2300000

14500000

235

170M7592 170M7546 

2200

3100000

19500000

245

170M7107 170M7516 

2400

4000000

25000000

255

170M7595 170M7978 

2500

4500000

28000000

260

Catalog Numbers

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body Flush End Contact Size 4 — 1250V (IEC):
1400-2500A

Dimensions - mm 

Type 4BKN/ 105

Type 4SBKN/ 105

106.6

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

196

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

197

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Square Body Flush End Contact Size 4 — 1250V (IEC):
1400-2500A

Size 4 — 2300-2500A: 1250V

Time-Current Curve

Size 4 — 1400-2400A: 1250V

Time-Current Curve

Peak Let-Through Curve

Peak Let-Through Curve

Data Sheet: Available upon request

Data Sheet: Available upon request

Prospective Current in Amps RMS

Prospective Current in Amps RMS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body Flush End Contact Size 23— 1250V
(IEC/UL): 630-2800A

1250V (IEC) 630-2800A

Specifications

Description:

High speed square

body fuses, for the protection of the
power rectifier section of the 
equipment.

Dimensions:

See dimensions 

illustration.

Ratings:

Volts: — 1250Vac (IEC)

Amps: — 630-2800A

IR: — 125kA RMS Sym.

Agency Information:

CE, Designed and tested to IEC

60269: Part 4. UL Recognized.

Electrical 

Characteristics

Total clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

Arc Voltage

This curve gives the
peak arc voltage, UL,

which may appear
across the fuse during
its operation as a 
function of the applied
working voltage Eg ,

(rms) at a power factor
of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

For Other Voltage Ratings in This Body Style  

• See pages 165 (660V) and 185 (1000V)

Catalog Numbers

170M6775 170M6795 170M6785 

630

38000

310000

170

170M6776 170M6796 170M6786 

700

54000

440000

180

170M6777 170M6797 170M6787 

800

78000

640000

190

170M6805 170M6807 170M6806 

900

120000

980000

200

170M6778 170M6798 170M6788 

1000

155000

1250000

210

23

170M6779 170M6799 170M6789 

1250 

1100

220000

1750000

220

170M6780 170M6800 170M6790 

1250

330000

2700000

230

170M6781 170M6801 170M6791 

1400

460000

3800000

240

170M6782 170M6802 170M6792 

1600

820000

5200000

250

170M6783 170M6803 170M6793 

1800

1200000

7600000

260

170M6784 170M6804 170M6794 

2000

1800000

11000000

270

170M6815 170M6833 170M6827 

2200

2300000

14500000

280

170M6816 170M6834 170M6828 

1100

2500

3200000

16000000

290

170M6817 170M6835 170M6829 

2800

5000000

24000000

300

-BU/75

without

Indicator

Catalog Number

Electrical Characteristics

I

2

t (A

2

Sec)

-BKE/75

Type K

Indicator

-BKN/75

Type K

Indicator

-BU/80

without

Indicator

-BKE/80

Type K

Indicator

-BKN/80

Type K

Indicator

Watts

Loss

(W)

Rated

Voltage

(V)

Rated

Current

RMS-Amp

Fuse
Size

Pre-arc

Clearing at

1250V

† A

2

s @ 1000V

Data Sheet: 170K6638

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

198

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

199

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Square Body Flush End Contact Size 23— 1250V
(IEC/UL): 630-2800A

Size 23 — 630-2800A: 1250V

Time-Current Curve

Peak Let-Through Curve

Prospective Current in Amps RMS

Dimensions - mm

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body Flush End Contact Size 5— 1000V-2000V:
1800-5000A

1000V (IEC) 1800-5000A

Specifications

Description:

High speed

square body fuses, for the 
protection or isolation for 
components such as diodes,
silicon controlled rectifiers
(SCRs), Gate torn-Off
Thyristors (GTOs) and IGBTs. 

Dimensions:

See dimensions 

illustration.

Ratings:

Volts: — 1000-2000Vac (IEC)

Amps: — 1800-5000A

IR: — 300kA RMS Sym. estimated, 197kA tested

Agency Information:

Consult Bussmann.

bulehighspeedtechnical@cooperindustries.com

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• AC and DC drives
• High power converters/rectifiers

This dimension drawing is an example of the range of size 5 fuses available.

Dimensions - mm (in)

Contact Bussmann for available parts and technical information.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed Fuses

200

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

201

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

High Speed

Fuses

High Speed Fuses

Square Body DC Fuses — 750Vdc:  63-500A

750Vdc 63-500A

Specifications

Description:

High speed fuses, for the 

protection of DC circuits in equipment.

Dimensions:

See dimensions 

illustration.

Ratings:

Volts: — 750Vdc

Amps: — 63-500A

IR: — 750Vdc IR: 100kA, L/R = 100 ms.

— 1000Vdc IR: 100kA, L/R = 40 ms

Agency Information:

Consult Cooper

Bussmann.

Electrical Characteristics

Arc Voltage

This curve gives the
peak arc voltage, UL,

which may appear
across the fuse during
its operation as a 
function of the applied
working voltage Eg.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC common bus
• DC drives
• Power converters/rectifiers
• Reduced voltage starters

Catalog Numbers

170E3577 170E3583 

63

10.0

170E3578 170E3584 

80

13.0

1*

170E3579 170E3585 

100

16.0

170E3580 170E3586 

125

21.0

170E3581 170E3587 

160

26.0

1

170E5417 170E5420  750

200

37.0

170E5418 170E5421 

250

46.0

170E8335 170E8345 

250

47.0

2

170E8336 170E8346 

315

57.0

170E8337 170E8347 

400

73.0

3

170E9681 170E9685 

500

91.0

-BK/130

-EK/-

Catalog Numbers

Electrical Characteristics

Watt

Loss

(W)

Rated

Voltage

(Vdc)

Rated

Current

RMS-Amp

Fuse

Size

Data Sheet: Size 1*: 170K3620

Size 1:

170K3622

Size 2:

170K3624

Size 3:

170K3626

Microswitch: 170H0069, 170H3027 (gold)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body DC Fuses — 750Vdc:  63-500A

Dimensions - mm

Type – BK/ 130

Type – EK/ -

Size/Type

A

B

1* BK/130

129

43

61

1 BK/130

130

51

69

2 BK/130

130

59

77

3 BK/130

131

74

90

Size/Type

A

B

C

D

E

F

G

H

I

1* EK/155

124

156

129

180

43

36

41

9

9

18

1 EK/165

124

166

129

191

51

37

41

11

14

25

2 EK/170

124

170

129

205

59

42

48

13

21

30

3 EK/170

125

170

130

206

74

51

56

13

20

36

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

High Speed Fuses

202

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

203

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

High Speed

Fuses

High Speed Fuses

Square Body DC Fuses — 750Vdc:  63-500A

Square Body DC Fuse — 200-250A: 750V

Time-Current Curve

Square Body DC Fuse — 63-160A: 750V

Time-Current Curve

Peak Let-Through Curve

Peak Let-Through Curve

Data Sheet: Available upon request

Data Sheet: Available upon request

Prospective Current in Amps RMS

Prospective Current in Amps RMS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body DC Fuses — 750Vdc:  63-500A

Square Body DC Fuse — 500A: 750V

Time-Current Curve

Square Body DC Fuse — 250-400A: 750V

Time-Current Curve

Peak Let-Through Curve

Peak Let-Through Curve

Data Sheet: Available upon request

Data Sheet: Available upon request

Prospective Current in Amps RMS

Prospective Current in Amps RMS

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

High Speed Fuses

204

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

205

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

High Speed

Fuses

High Speed Fuses

Square Body DC Fuses — 1200Vdc:  160-420A

1200Vdc 160-420A

Specifications

Description:

High speed fuses that 

provide superior protection in light and
heavy harsh DC traction applications as
1200Vdc and below circuits, and as DC
link/power converters.

Dimensions:

See dimensions 

illustration.

Ratings:

Volts: — 1200Vdc

Amps: — 160-420A

IR: — 1200Vdc = 100kA L/R: 15 ms.

Agency Information:

Consult Cooper Bussmann.

Electrical 

Characteristics

Arc Voltage

This curve gives the
peak arc voltage, UL,

which may appear
across the fuse during
its operation as a 
function of the applied
working voltage Eg.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Catalog Numbers

Dimensions - mm 

170F8230

160

12000

20000

75.0

170F8231

200

20000

35000

85.0

2SKN / 140

170F8232

1200

250

43000

75000

94.0

170F8233

315

87000

150000

104.0

170F8234

400

180000

310000

120.0

170F8235 420

215000

375000

122.0

-SKNB/140

Type K

Indicator 

Electrical Characteristics

Max I

2

t (A

2

Sec) @ 1000Vdc

Watts

Loss

(W)

Rated

Voltage

(Vdc)

Rated

Current

RMS-Amp

Fuse

Type

Cat. 

Numbers

L/R = 15ms

L/R = 45ms

Data Sheet: 170K5520
Microswitch: 170H0069, 170H3027 (gold)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body DC Fuses — 1200Vdc:  160-420A

Square Body DC Fuse — 160-420A: 1200V

Time-Current Curve

Data Sheet: Available upon request

Prospective Current in Amps RMS

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

High Speed Fuses

206

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

207

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

High Speed

Fuses

High Speed Fuses

Square Body DC fuses — 2000Vdc:  10-125A

2000Vdc 10-125A

Specifications

Description:

High speed fuses for the 

protection of DC circuits in equipment.

Dimensions:

See dimensions 

illustration.

Ratings:

Volts: — 1200Vdc

Amps: — 160-420A

IR: — 1200Vdc = 100kA L/R: 15 ms.

Agency Information:

Consult Bussmann.

Electrical 

Characteristics

Arc Voltage

This curve gives the
peak arc voltage, UL,

which may appear
across the fuse during
its operation as a 
function of the applied
working voltage Eg.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the RMS load current, Ib, in % of the

rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Catalog Numbers

170E3976 10

7

170E3970 16

11

170E3950 20

13

170E3951 25

17

1*SKN/246 170E3952 2000 

32

22

170E3953 40

27

170E3954 50

34

170E3955 63

43

170E3956 80

50

-SKN/246

Type K

Indicator

Rated

Current

RMS-Amp

Cat. Number

Electrical Characteristics

Watt

Loss

(W)

Rated

Voltage

(Vdc)

Fuse 
Type

170E3937 20

13

170E3938 25

16

170E3939 32

20

170E3940 40

25

1*SKN/246

170E3941 2000 

50

32

170E3942 63

40

170E3943 80

51

170E3944 100

64

170E3945 125

80

-SKN/246

Type K

Indicator

Rated

Current

RMS-Amp

Cat. Number

Electrical Characteristics

Watt

Loss

(W)

Rated

Voltage

(Vdc)

Fuse

Type

Dimensions - mm

Data Sheet: 170K4538
Microswitch: 170H0239, 170H3030 (gold)

Data Sheet: 170K4900
Microswitch: 170H0239, 170H3030 (gold)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Square Body DC fuses — 2000Vdc:  10-125A

Square Body DC Fuses — 10-80A: 2000V

Time-Current Curve

Peak Let-Through Curve

Data Sheet: Available upon request

Prospective Current in Amps RMS

Square Body DC Fuses — 20-125A: 2000V

Time-Current Curve

Peak Let-Through Curve

Data Sheet: Available upon request

Prospective Current in Amps RMS

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

High Speed Fuses

208

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

209

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

High Speed

Fuses

High Speed Fuses

Square Body DC Fuses — 4000Vdc:  20-450A

4000Vdc 20-450A

Specifications

Description:

High speed fuses for the 

protection of DC circuits in equipment.

Dimensions:

See dimensions 

illustration.

Ratings:

Volts: — 4000Vdc

Amps: — 20-450A

IR: — 60kA L/R: 25 ms.

Agency Information:

Consult Bussmann.

Electrical 

Characteristics

Arc Voltage

This curve gives the
peak arc voltage, UL,

which may appear
across the fuse during
its operation as a 
function of the applied
working voltage Eg.

Power Losses

Watts loss at rated current is
given in the electrical charac-
teristics. The curve allows the
calculation of the power loss-
es at load currents lower than
the rated current. The 
correction factor, Kp, is given

as a function of the RMS load
current, Ib, in % of the rated current.

Features and Benefits

• Excellent DC performance
• Low arc voltage and low 

energy let-through (I

2

t)

• Low watts loss
• Superior cycling capability

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Catalog Numbers

170E3914 20

23

170E3915 25

28

170E3916 32

34

170E3917 40

45

1*SKN/394

170E3918 50

57

170E3919 63

72

170E3984 80

91

170E3933 4000 

100

114

170E3922 125

143

170E8882

160

182

2 SKN/394 

170E8883

200

228

170E8884

250

285

170E8885 315

360

2//2SKN/394

170E8886 350

400

170E8887 400

455

170E8888 450

515

-SKN/394

Type K

Indicator

Cat. Numbers

Electrical Characteristics

Watts

Loss

(W)

Rated

Voltage

(Vdc)

Rated

Current

RMS-Amp

Fuse

Type

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

DC Fuses — 4000Vdc:  20-450A

Dimensions - mm

Type 1* SKN/ 394

Type 2SKN/ 394

Type  2/ / SKN/ 394

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

High Speed Fuses

210

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

211

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

High Speed

Fuses

High Speed Fuses

Square Body DC Fuses — 4000Vdc:  20-450A

Square Body DC Fuses — 20-125A: 2000V

Time-Current Curve

Peak Let-Through Curve

Data Sheet: Available upon request

Prospective Current in Amps RMS

Square Body DC Fuses — 160-450A: 4000V

Time-Current Curve

Peak Let-Through Curve

Data Sheet: Available upon request

Prospective Current in Amps RMS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

DIN 43 653

DIN 43 620

French Style

Flush End

US Style

Size

Type T

Type K

Type T

Type K

Type T

Type K

Type T

Type K

Type K

000

170H0236

170H0236

170H0238

170H0238

00

170H0235

170H0235

170H0237

170H0237

1*

170H0235

170H0069

170H0235

170H0236

170H0069

170H0069

170H0069

170H0237

170H0237

170H0238

1

170H0235

170H0069

170H0236

170H0069

170H0069

170H0069

170H0237

170H0238

2

170H0235

170H0069

170H0235

170H0236

170H0069

170H0069

170H0069

170H0237

170H0237

170H0238

3

170H0235

170H0069

170H0236

170H0236

170H0069

170H0069

170H0069

170H0237

170H0238

170H0238

4

170H0069

23

170H0069

24

170H0069

Square Body Fuse Accessories

Indicator Systems

Typower ZILOX fuses are available with three different 
indicator systems.

1. Visual Indicator

The indicator situated in one cover plate is clearly visible as
soon as the fuse has operated. The minimum voltage for
operating the indicator is 20V.

2. Type T Indicator

The indicator is situated on one cover plate with a cover
plate tag to accommodate an auxiliary switch. The minimum
voltage for operating the indicator is 20V. A special low 
voltage indicator (1.5V) is available on request.

3. Type K Indicator

This indicator is situated on the fuse body. It is covered by
an adapter for snap-on mounting of an auxiliary switch. The
operating voltage of the indicator is 1.5V. As a matter of 
safety, the factory mounted adapter must not be removed
from the fuse.

Microswitch

The Typower ZILOX fuses with either type T indicator or type
K indicator can be equipped with a microswitch for remote
electrical indication of fuse operations. All microswitches
have one normally open and one normally closed contact.
Ratings are 2A, 250Vac.

6.3 x 0.8mm

2.8 x 0.5mm

Indicator

Microswitch

Lugs

Lugs

Type

170H0235

X

T

170H0236

X

T

170H0237

X

T

170H0238

X

T

170H0069

X

K

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

High Speed Fuses

212

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

213

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

High Speed

Fuses

High Speed Fuses

Square Body Fuse Accessories

1BS Series Example

170H3004

170H1013

Fuse Bases (Blocks)

DIN 43 653 Fuse Bases

For the Typower ZILOX fuses according to DIN 43 653, the
following fuse bases are available:

Catalog

Max

Amp

Center

Number

Volts

Rating

Distance

170H3003

1000

630

80mm

170H3004

1000

1250

80mm

170H3005

1400

630

110mm

170H3006

1400

1250

110mm

The fuse bases rated 1250A can also be used for the fuses
with higher rated current if the maximum load current is 
derated according to the table below:

Fuse Amp

Max Amp Load

Rating

In Fuse Base

1400

1325

1500

1400

1600

1500

1800

1650

2000

1800

Fixed Center

Max

Max. Fuse

Fuse

Base Style

Volts

Amp Rating

Size

170H1007

1000

400

00, 000

170H1013

660

200

0000,000

UL Recognized to UL 512.

Universal Fuse Bases

For the Typower ZILOX fuses according to DIN 43 653,
French style and North American style, the following fuse
bases are available:

Modular

Max

Max. Fuse

Base Style

Volts

Amp Rating

Data Sheet

1BS101

600

100

1206

1BS102

600

400

1207

1BS103

600

400

1208

1BS104

600

600

1209

BH-0xxx

700

200

1200

BH-1xxx

2500

400

1201

BH-2xxx

5000

400

1202

BH-3xxx

1250

700

1203

Modular fuse bases are UL Recognized to UL 512 and meet
the spacing requirements of UL 347. Contact your Bussmann
sales representative for more complete ordering information.

DIN 43 620 Fuse Bases

Size

Part Number

000-00

SB00-D

1*, 1

SB1-D

2,3

SB2-D

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

214

High Speed Fuses

British BS 88 Fuses

General Information

Designed and tested to:

•  BS 88: Part 4
•  IEC 269: Part 4
•  UL Recognized

Bussmann offers the industry’s widest range of British style
semiconductor fuses and accessories.

Bussmann British style products use innovative arc 
quenching techniques and high grade materials to provide:

•  Minimal energy let-through (I

2

t)

•  Excellent DC performance
•  Good surge withstand profile

British style fuses are typically found in equipment 
manufactured in the United Kingdom or British
Commonwealth countries. However, North American 
manufacturers have begun to specify British style fuses —
particularly in UPS applications at 240V or less — to take
advantage of their size, performance and cost benefits.

Voltage Rating

All Bussmann British style fuses are tested to IEC 269: Part
4. This standard requires a test voltage which is 5% higher
than the rated voltage. In North America, fuses are required
to clear only their rated voltage.

Accessories

Trip-indicator fuses are available for use in parallel with the
main fuse. Indicator fuses can be attached to the associated
fuselink, or mounted separately in panel-mounted fuseclips.
In addition, a push-on adapter and microswitch attachment
are available, to provide remote indication. Fuse blocks are
also available for most applications.

Introduction

British BS 88 Contents

Fuse

Amp

Volts

Range

Page

240

6-900

215-217

690

6-710

218-221

Accessories

Indicator System &  Fuse Bases

222

British BS 88 Fuse Ranges

Amps

Vac

Vdc

6-900

240

150

6-710

690

500

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

215

High Speed

Fuses

High Speed Fuses

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The correc-
tion factor, Kp, is given as

a function of the RMS load
current, Ib, in % of the

rated current.

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Clearing

Watts

Numbers

Type

RMS-Amps

Pre-arc

at 120V

at 240V

Loss

6LCT

6

2

6

9

1.0

10LCT

10

3.8

12

22

2.5

12LCT

LCT

12

7

22

32

2.5

16LCT

16

20

50

100

2.5

20LCT

20

25

80

160

4.0

25LET

25

18

120

250

4.0

32LET

32

32

200

450

5.0

35LET

35

50

320

600

5.0

50LET

50

100

500

1400

7.0

63LET

LET

63

180

1100

2200

9.0

80LET

80

300

1900

3800

10.0

100LET

100

600

3800

7500

10.0

125LET

125

600

3800

7500

16.0

160LET

160

1100

7000

16000

20.0

180LETa

180

1600

12000

29000

21.0

160LMT

160

1100

7000

16000

17.0

200LMT

200

1500

10000

20000

28.0

250LMT

250

3200

20000

40000

28.0

315LMT

LMT

315

6000

35000

75000

35.0

355LMT

355

8000

50000

100000

35.0

400LMT

400

14000

70000

160000

40.0

450LMT

450

18000

100000

220000

42.0

400LMMT

400

6000

35000

80000

60.0

500LMMT

500

14000

80000

170000

64.0

630LMMT

LMMT

630

24000

150000

300000

75.0

710LMMT

710

32000

200000

460000

77.0

800LMMT

800

52000

300000

600000

82.0

900LMMT

900

75000

400000

800000

97.0

• Watts loss provided at rated current.
• Note: 7LET, 10LET, 12LET and 16LET are available for replacement purposes on existing

equipment.

• See accessories on page 222.

Features and Benefits

• Excellent cycling capability
• Excellent DC performance
• Low arc voltage and low 

energy let-through (I

2

t)

British BS 88 — 240V:  6-900A

56

41.8

26.2

17.7

19.1

12.7

7.1

9.7

Fig. 2: LET

47

38

28

6.4

8.4

8.7

4

5.5

Dimensions - mm

Fig. 1: LCT

1mm = 0.0394” / 1” = 25.4mm

LCT, LET, LMT, LMMT

Specifications
Description:

BS 88 style 

stud-mount fuses.

Dimensions:

See dimensions

illustrations.

Ratings:

Volts: — 240Vac/150Vdc

Amps: — 6-900A

IR: — 200kA RMS Sym.

Agency Information:

CE, Designed and tested to: BS 88

Part 4, IEC 269 Part 4, UL Recognized. All fuses above have
been tested at 318Vac. Consult Bussmann for specific UL
Recognition status.

Electrical Characteristics

Total Clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor
of 15% are given in the 
electrical characteristics. For
other voltages, the clearing
I

2

t is found by multiplying by

correction factor, K, given as
a function of applied working
voltage, Eg, (rms).

84

59

31

83

38

25.4

13.5

10.3

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

100

50

150

200

250

1)

2)

E

g

K

84

59

31

41

38.1

25.4

10.3

13.5

Fig. 3: LMT

Fig. 4: LMMT

Indicator (Optional)

1) LCT
2) LET, LMT, LMMT

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

750

500

250

100

200

300

1)

2)

E

g

U

L

1) LCT
2) LET, LMT, LMMT

Typical Applications

• DC Common bus
• AC and DC drives
• Power converters/rectifiers
• Reduced voltage starters

Data Sheet: 720004

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

British BS 88 — 240V:  6-900A

Peak Let-Through Curve

LET 25-180A: 240V

Time-Current Curve

LCT 6-20A: 240V

Time-Current Curve

10

4

10

3

10

2

10

–1

10

–2

10

–3

10

–4

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

2

4

6

8

10

1

2

2

4

6

8

2

10

2

2

4

6

8

10

3

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

20LCT

16LCT

12LCT

10LCT

6LCT

10

4

10

3

10

2

10

1

2

2

4

6

8

2

10

2

2

4

6

8 10

3

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

63LET

50LET

35LET

32LET

25LET

180LETa

160LET

125LET

100LET

 80LET

10

–4

10

–3

10

–2

10

–1

Prospective Short-Circuit Current Symmetrical RMS

10

1

10

2

2

6

4

2

4

6

10

3

2

4

6

10

4

2

4

6

10

5

P

eak Let-Through Current

  10

1

6

2

4

2

  10

2

4

6

2

10

3

6

4

10

4

6

4

2

2

10

5

SYMMETRICAL FAULT

FULLY ASYMMETRICAL FAULT

20LCT
16LCT
12LCT
10LCT

 6LCT

25LET

32LET

35LET

50LET

63LET

 80LET

125 & 100LET

160LET & LMT

200LMT

180LET

250LMT

315LMT

355LMT

400 & 500LMMT

450LMT

630LMMT

710LMMT

800LMMT

900LMMT

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

216

High Speed Fuses

Data Sheet: 35785296

Data Sheet: 35785293

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

217

High Speed

Fuses

High Speed Fuses

British BS 88 — 240V:  6-900A

10

–4

10

–3

10

–1

10

2

10

2

2

2

4

6

8

2

10

3

2

4

6

8

10

4

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

10

4

315LMT

450LMT

400LMT

355LMT

250LMT

200LMT

160LMT

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

10

3

10

–2

10

–1

10

–3

10

–2

10

2

10

3

10

4

10

2

2

2

4

6

8

2

10

3

2

4

6

8 10

4

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

10

–4

710LMMT

900LMMT

800LMMT

630LMMT

500LMMT

400LMMT

Prospective Short-Circuit Current Symmetrical RMS

10

1

10

2

2

6

4

2

4

6

10

3

2

4

6

10

4

2

4

6

10

5

P

eak Let-Through Current

  10

1

6

2

4

2

  10

2

4

6

2

10

3

6

4

10

4

6

4

2

2

10

5

SYMMETRICAL FAULT

FULLY ASYMMETRICAL FAULT

20LCT
16LCT
12LCT
10LCT

 6LCT

25LET

32LET

35LET

50LET

63LET

 80LET

125 & 100LET

160LET & LMT

200LMT

180LET

250LMT

315LMT

355LMT

400 & 500LMMT

450LMT

630LMMT

710LMMT

800LMMT

900LMMT

Peak Let-Through Curve

LMMT 400-900A: 240V

Time-Current Curve

LMT 160-450A: 240V

Time-Current Curve

Data Sheet: 35785294

Data Sheet: 35785295

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

British BS 88 — 690V:  6-710A

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

218

High Speed Fuses

CT, ET, FE, EET, FEE, FM, FMM, MT, MMT

Specifications
Description:

BS 88 style 

stud-mount fuses.

Dimensions:

See dimensions

illustrations.

Ratings:

Volts: — 690Vac/500Vdc

Amps: — 6-710A

IR: — 200kA RMS Sym.

Agency Information:

CE, Designed and tested to: BS 88

Part 4, IEC 269 Part 4, UL Recognized. MT and MMT —
350Vdc (IEC) rating. Consult Bussmann for UL Recognition
status.

Electrical 

Characteristics

Total Clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor
of 15% are given in the 
electrical characteristics. For
other voltages, the clearing
I

2

t is found by multiplying by

correction factor, K, given as
a function of applied working
voltage, Eg, (rms).

Dimensions - mm

Fig. 1: CT

77

63.5

48

17.1

19.1

12.7

7.1

9.7

94

70

46

37

19

31.8

8.7

11.9

113

A

50

41

38.1

25.4

10.3

13.5

113

A

50

83

38

25.4

10.3

14

Fig. 2: ET, FE

74.6

64.3

54.8

6.4

8.7

8.7

4

5.5

Fig. 3: EET, FEE

Fig. 4: FM, MT

Fig. 5: FMM, MMT

1mm = 0.0394” / 1” = 25.4mm

Figs. 4 & 5 “A” Dimensions

Type

“A”

FM

80-85mm

FMM

80-85mm

MT

85mm

MMT

85mm

Arc Voltage

This curve gives the
peak arc voltage, UL,

which may appear
across the fuse during its
operation as a function
of the applied working
voltage, Eg, (rms) at a

power factor of 15%.

Power Losses

Watts loss at rated 
current is given in the
electrical characteristics.
The curve allows the
calculation of the power
losses at load currents
lower than the rated 
current. The correction
factor, Kp, is given as a

function of the RMS load
current, Ib, in % of the
rated current.

Features and Benefits

• Excellent cycling capability
• Excellent DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

1500

1000

500

200

400

600 660

E

g

U

L

1)

2)

1) CT
2) ET, FE, EET, FEE, FM, FMM

200

300

400

500

600

690

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1)

2)

E

g

K

1) CT, ET, EET, FE, FEE, MT, MMT
2) FM, FMM

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

Data Sheet: 720024

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

219

High Speed

Fuses

High Speed Fuses

British BS 88 — 690V:  6-710A

10

3

10

–1

2

4

6

8

10

1

2

2

4

6

8

2

10

2

2

4

6

8 10

3

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

10CT
12CT
16CT
20CT

 6CT

32ET

25ET

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

56ET

80ET

63ET

45ET

40ET

35ET

10

–4

10

–3

10

–2

10

2

10

4

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

2

4

2

6

6

4

2

4

6

4

2

6

4

2

6

2

4

6

2

4

6

2

4

6

2

4

6

10

1

10

2

10

3

10

4

10

5

10

1

10

2

10

3

10

4

10

5

2

20CT
16CT
12CT
10CT

6CT

80ET
63ET
56ET
45ET
40ET
35ET
32ET
25ET

710MMT
630MMT
560MMT
500MMT
450MMT

315MT  355MT  400MMT

280MT  355MMT
250MT  315MMT

280MMT

 200MT

180MT  225MMT
160MT  200MMT

180MMT

160EET
140EET
110EET
90EET

Peak Let-Through Curve

CT 6-20, ET 25-80A: 690V

Time-Current Curve

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Clearing

Watts

Numbers

Type

RMS-Amps

Pre-arc

at 415V

at 660V

Loss

6CT

6

1.8

8.5

12

2

10CT

10

7

30

48

3

12CT

CT

12

10

40

65

3

16CT

16

16

66

110

7

20CT

20

32

150

220

7

25ET

25

25

150

250

7

32ET

32

32

190

350

11

35ET

35

52

310

500

11

40ET

ET

40

103

600

900

9

45ET

45

103

680

1100

11

56ET

56

135

950

1500

14

63ET

63

171

1200

2000

16

80ET

80

360

2500

4000

18

35FE

35

33

130

200

9

40FE

40

52

180

300

9

45FE

45

76

270

450

11

50FE

50

103

380

600

11

63FE

FE

63

135

480

750

12

71FE

71

210

600

950

17

80FE

80

250

900

1500

20

90FE

90

360

1300

2100

20

100FE

100

470

1800

2800

23

90EET

90

490

3000

4500

19

110EET

EET

110

600

4000

6500

27

140EET

140

1050

7000

12000

35

160EET

160

1500

10000

17000

39

100FEE

100

400

1600

2400

24

120FEE

120

540

1900

3100

32

140FEE

FEE

140

850

2500

3800

36

160FEE

160

1000

3700

5700

46

180FEE

180

1400

5300

8400

46

200FEE

200

1900

7100

11400

52

180FM

180

1400

7500

13500

40

200FM

200

2600

10500

18500

40

225FM

225

3700

14500

26500

44

250FM

FM

250

5200

20500

37500

48

280FM

280

7000

30500

55000

48

315FM

315

10000

40000

77000

55

350FM

350

15000

60000

105000

55

400FMM

400

10000

40000

72500

85

450FMM

450

15000

60000

105000

90

500FMM

FMM

500

20000

82000

150000

100

550FMM

550

30000

120000

215000

100

630FMM

630

45000

180000

310000

100

700FMM

700

60000

245000

420000

120

160MT

160

2400

15000

25000

26

180MT

180

3800

25000

38000

26

200MT

200

6000

40000

58000

27

250MT

MT

250

11500

80000

110000

32

280MT

280

16500

100000

150000

35

315MT

315

19000

125000

180000

42

355MT

355

22000

160000

200000

51

180MMT

180

1650

12000

18000

42

200MMT

200

2200

16000

23000

42

225MMT

225

3700

26000

40000

42

280MMT

280

6600

47000

70000

47

315MMT

315

8600

62000

91000

51

355MMT

MMT

355

13500

97000

140000

54

400MMT

400

21000

150000

220000

60

450MMT

450

30000

220000

320000

57

500MMT

500

42000

300000

450000

64

560MMT

560

60000

430000

640000

64

630MMT

630

68500

500000

720000

86

710MMT

710

78000

600000

850000

105

• Watts loss provided at rated current.
• Note: FC, 8ET, 12ET, 15ET, 20ET, 65EET and 75EET are available for replacement 

purposes on existing equipment.

• See accessories on page 222.

Data Sheet: 35785312

Catalog Numbers

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

British BS 88 — 690V:  6-710A

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

220

High Speed Fuses

10

3

10

4

10

2

10

–1

10

–2

2

4

6

8

10

2

2

2

4

6

8

2

10

3

2

4

6

8 10

4

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

160EET

140EET

110EET

90EET

200MT

355MT

315MT

280MT

250MT

180MT

160MT

10

–4

10

–3

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

2

4

2

6

6

4

2

4

6

4

2

6

4

2

6

2

4

6

2

4

6

2

4

6

2

4

6

10

1

10

2

10

3

10

4

10

5

10

1

10

2

10

3

10

4

10

5

2

20CT
16CT
12CT
10CT

6CT

80ET
63ET
56ET
45ET
40ET
35ET
32ET
25ET

710MMT
630MMT
560MMT
500MMT
450MMT

315MT  355MT  400MMT

280MT  355MMT
250MT  315MMT

280MMT

 200MT

180MT  225MMT
160MT  200MMT

180MMT

160EET
140EET
110EET
90EET

Peak Let-Through Curve

EET 90-160A, MT 160-355A: 690V

Time-Current Curve

10

4

10

3

10

2

10

–1

10

–3

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

10

2

2

2

4

6

8

2

10

3

2

4

6

8

10

4

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

280MMT

355MMT

315MMT

225MMT

200MMT

180MMT

630MMT
710MMT

560MMT

500MMT

450MMT

400MMT

10

–4

10

–2

MMT 180-710A: 690V

Time-Current Curve

Data Sheet: 35785313

Data Sheet: 35785311

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

221

High Speed

Fuses

High Speed Fuses

British BS 88 — 690V:  6-710A

10

4

10

3

10

2

10

–1

10

–2

10

–3

10

–4

10

2

2

2

4

6

8

2

10

3

2

4

6

8

10

4

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

120FEE
140FEE
160FEE
180FEE
200FEE

100FEE

550FMM

700FMM

630FMM

500FMM

450FMM

400FMM

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

FEE 100-200A & FMM 400-700A: 690V

Time-Current Curve

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

10

2

2

4

6

2

4

6

10

3

8

2

8

4

6

10

4

2

4

6

8

10

3

2

4

6

10

4

2

4

6

10

5

2

180FEE

100FEE

120FEE

140FEE

160FEE

200FEE

400FMM

450FMM

500FMM

550FMM

630FMM

700FMM

Peak Let-Through Curve

10

3

10

2

10

–1

10

–2

10

–4

2

4

6

8

10

2

2

2

4

6

8

2

10

3

2

4

6

8 10

4

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

100FE

35FE
40FE
45FE
50FE
63FE
71FE
80FE
90FE

350FM

315FM

280FM

250FM

220FM

200FM

180FM

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

10

–3

10

4

FE 35-100A & FM 180-350A: 690V

Time-Current Curve

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

2

4

2

6

6

4

2

6

4

2

6

4

2

4

6

2

4

6

2

4

6

2

4

6

10

1

10

2

10

3

10

4

10

5

10

1

10

2

10

3

10

4

10

5

2

350FM
315FM
280FM
250FM
225FM
200FM
180FM

100FE
90FE
80FE
71FE
63FE
50FE
45FE
40FE
35FE

Peak Let-Through Curve

Data Sheet: 35785314

Data Sheet: 35785292

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

British BS 88 Fuse Accessories

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

222

High Speed Fuses

Indicator System

Trip-Indicators

Trip-indicators are available for use in parallel with the
main fuse. They can either be attached to the associated
fuse or mounted separately in panel mounted fuse clips,
reference CL1. A push-on adapter and microswitch 
attachment is available for use with the trip indicator to
give the facility of remote indication, reference MAI.

Fuse ratings of 20A and below cannot usually 
accommodate a trip-indicator.

When a trip-indicator is to be attached to the main fuse an
accessory pack comprising a pair of mounting clips and an
appropriate trip indicator would be required. The clips are
snapped onto the fuse end caps and the indicator is
pressed into clips as shown.

Electrical Specifications

Type

TI500

TI700

Maximum RMS Voltage

500

700

Maximum Peak Voltage

700

1000

Maximum DC Voltage

130

350

Cold Resistance (ohms)

0.3

0.45

Maximum permissible steady-state current

1.5A

1.5A

Interrupting Capacity (RMS Symm.)

100,000

100,000

Pre-Arcing I

2

t

23

23

Total I

2

t (max volts)

46

46

Microswitch Adapter – MAI

We offer a microswitch, complete with adapter for 
securing the indicator. The microswitch is provided with
double pole, single throw contacts, having both a normally
open and a normally closed position. A special material has
been employed in the construction of the adapter to 
provide reliable operation in the range of temperatures
associated with standard operating conditions and during
fuse operation.

Microswitch and Adapter Type MAI

Current Rating:

AC 50/60Hz resistive load @ 250V RMS

4A

AC 50/60Hz resistive load @ 127V RMS

6A

DC, resistive load @ 110Vdc

0.7A DC

DC, resistive load @ 30Vdc

2A DC

Maximum Working Voltage:

Contact-to-contact (RMS)

1000V

Contact-to-contact (RMS)

1500V

Maximum DC Volts:

110Vdc

Ref.

Dim. “A” (mm)

RMS Volts

TI250

37.6

250

TI500

47.5

500

TI600

55.7

600

TI700

61.8

700

TI1100

98.4

1100

TI1500

120.6

1500

TI2000

147.5

2000

TI2500

198.3

2500

RMS

For use

Kit. Ref.

Details

Volts

with Fuse Ref.

EC-250

Fuse Mount

250

LET

MC250

Indicator Kits

250

LMT & LMMT

EC-600

(Includes one

660

FE, FEE & ET

MC600

indicator

660

FM & FMM

MC700

and two clips)

700

MT & MMT

E

C

A

B

D

F

6

21

0.8

6.8

6.35

NO
NC

NC
NO

Terminal Arrangement

Trip-Indicator 
Dimensions - mm

Dimensions in mm

Fuse Indicator Kits

6.0

8.7

50.8

B

14

CL1 Panel Mount Clips

CL1 Panel mount fuse clips
are available for mounting a
trip-indicator when mounting
directly on the fuse is 
impractical. Order part 
number CL1.

CL1 Panel Mount Clip 
Dimensions - mm

Trip 
Indicator

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

223

High Speed

Fuses

Table of Contents

Basic Catalog

Amp

Number

Volts

Range

Page

FWA

150

5-60

224-225

FWX

250

1-50

226-227

FWH

500

0.25-30

228-231

FWC

600

6-32

232-233

FWP

690V/700

1-100

234-237

FWK

750

5-60

238-239

FWJ

1000

20-30

240-241

FWL/FWS

1250/1500/2000

2-30

242

Accessories

Fuse Holders

241

Ferrule Fuse Ranges

Volts

Amps

AC

DC

150

5-60

X

X

250

1-50

X

X

500

0.25-30

X

X

600

6-32

X

X

700 (22 x 58mm)

20-100

X

700 (14 x 51mm)

1-50

X

X

750

5-60

X

X

1000

20-30

X

X (800Vdc)

1250

20-30

X

X (1000Vdc)

1500

8-15

X

X (1000Vdc)

2000

2-6

X

X (1000Vdc)

General Information

Bussmann offers a full line of ferrule style (cylindrical 
clip-mounted) fuses, designed and tested to meet standards
and requirements in various locations around the world.
Their unique design and construction provide:

• Superior cycling capability
• Low energy let-through (I

2

t)

Ferrule fuses provide an excellent solution for small UPS,
small ac drives and other low power applications where
space is at a premium.

Voltage Rating

All Bussmann ferrule fuses — except 690V — have been
tested at their rated voltage. The 690V ferrule fuse has been
tested to the IEC 60269 standard, which requires clearing at
the rated voltage +5%.

Accessories

Ferrule fuses may be mounted in fuseclips, fuse holders,
fuse blocks or fused switches. A variety of products are 
available. Please consult Bussmann Application Engineering
to discuss your requirement.

Ferrule Fuses

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

224

High Speed Fuses

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Catalog Numbers

Electrical Characteristics

I

2

t (A

2

Sec)

Rated

Catalog

Current

Clearing

Watts

Numbers

Size

RMS-Amps

Pre-arc

at 150V

Loss

FWA-5A10F

5

1.6

8

1

FWA-10A10F

10

3.6

16

2.7

FWA-15A10F

10 x 38mm

15

14

55

3.3

FWA-20A10F

(

13

32

” x 1

1

2

”)

20

33

130

3.8

FWA-25A10F

25

58

220

4.9

FWA-30A10F

30

100

400

4.9

FWA-35A21F

35

75

800

4.5

FWA-40A21F

21 x 51mm

40

100

1000

5.1

FWA-45A21F

(

13

16

” x 2”)

45

130

1300

6

FWA-50A21F

50

170

1600

7.3

FWA-60A21F

60

250

2400

8.0

• Watts loss provided at rated current.
• See accessories on page 243.

Features and Benefits

• Excellent cycling capability and DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss in a compact size
• Used with finger-safe holders/blocks

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Ferrule — FWA 150V: 5-60A

Dimensions - in (mm)

Amp

Dimensions

Range

A

B

C

5-30

1.5 (38.1)

0.375 (9.5)

0.406 (10.3)

35-60

2.0 (50.8)

0.625 (15.9)

0.811 (20.6)

U

L

E

g

200

100

100

150

50

300

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

A

B

C

FWA 5-30A (10 x 38mm)

35-60A (21 X 51mm)

Specifications
Description:

Ferrule style high

speed fuses.

Dimensions:

See dimensions 

illustration.

Ratings:

Volts: — 150Vac/dc

Amps: — 5-60A

IR: — 100kA Sym.

Agency Information:

CE, UL Recognition JFHR2.E91958

Electrical 

Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

150

102

70

22

1.5

1.0

0.5

0.3

0.2

0.15

Eg

K

1)

2)

1) 5-30A Range
2) 35-60A Range

Data Sheet: 720003

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

225

High Speed

Fuses

Ferrule — FWA 150V: 5-60A

10

–4 

2 4 

10

2 4 

10

2 4 

10


10


10





10

–1 

10

–2 

10

–3 

10

10

10

FWA-10A10F 

FWA-30A10F 

FWA-25A10F 

FWA-20A10F 

FWA-15A10F 

FWA-5A10F 

V

irtual Pre-Arcing 

T

ime In Seconds 

Prospective Current In Amps RMS

10

1

2

2

4

6

8

2

10

2

2

4

6

8

10

3

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

10

–1

10

–2

10

–3

10

–4

10

2

10

3

10

4

FWA-45A21F
FWA-50A21F
FWA-60A21F

FWA-35A21F
FWA-40A21F

V

irtual Pre-Arcing 

T

ime In Seconds

Prospective Current In Amps RMS

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Through Current

2

4

2

6

6

4

2

6

4

2

4

6

2

4

6

2

4

6

2

4

6

10

1

10

2

10

3

10

4

10

1

10

2

10

3

10

4

10

5

FWA-20A10F

FWA-25A10F

FWA-30A10F

FWA-15A10F

FWA-12A10F

FWA-5A10F

FWA-10A10F

2

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Through Current

2

4

2

6

6

4

2

6

4

2

4

6

2

4

6

2

4

6

2

4

6

10

1

10

2

10

3

10

4

10

1

10

2

10

3

10

4

10

5

FWA-35A21F

FWA-40A21F

FWA-45A21F

FWA-50A21F

FWA-60A21F

2

Peak Let-Through Curve

Peak Let-Through Curve

FWA 35-60A: 150V (21 x 51mm)

Time-Current Curve

FWA 5-30A: 150V (10 x 38mm)

Time-Current Curve

Data Sheet: 35785317

Data Sheet: 35785305

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

226

High Speed Fuses

Ferrule — FWX 250V (UL): 1-50A

FWX (14 x 51mm)

Specifications
Description:

Ferrule style high

speed fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 250Vac/dc

Amps: — 1-50A

IR: — 200kA RMS Sym.

— 50kA @ 250Vdc

Agency Information:

CE, UL Recognition JFHR2.E91958

1-50A & CSA Component Acceptance file Class 1422-30,
1422-90 (53787) 5-30A

Electrical

Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

Dimensions - mm (in)

50.8

(2.000")

15.5

(0.610")

14.3

(0.563")

Arc Voltage

This curve gives the
peak arc voltage, UL,

which may appear
across the fuse during
its operation as a 
function of the applied
working voltage, Eg,

(rms) at a power factor
of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Watts

Number

Size

RMS-Amps

Pre-arc

at 250V

Loss

FWX-1A14F

1

FWX-2A14F

2

FWX-3A14F

3

FWX-4A14F

4

FWX-5A14F

14 x 51mm

5

1.6

13

1.3

FWX-10A14F

(

9

16

” x 2”)

10

3.6

24

3.4

FWX-15A14F

15

14

83

3.8

FWX-20A14F

20

33

200

4.6

FWX-25A14F

25

58

300

5.3

FWX-30A14F

30

100

500

5.9

FWX-50A14F

50

200

1800

5.7

• Watts loss provided at rated current.
• (250Vdc/Interrupting rating 50kA) UL Recognition & CSA Component Acceptance on 5
through 30A only. Consult Bussmann for additional ratings.
• See accessories on page 243.

Features and Benefits

• Excellent cycling capability and DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss in a compact size
• Used with finger-safe holders/blocks

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

1.5

1.0

0.5

0.3

0.2

0.15

75

125

300

200

250

E

g

K

1)

2)

U

L

1.4
1.2

10

3

800

600

500

400

300

200

50

100

150

200

250

E

g

1)

2)

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

Data Sheet: 720006

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

227

High Speed

Fuses

Ferrule — FWX 250V (UL): 1-50A

Prospective Current In Amps RMS

Prospective Current In Amps RMS

Peak Let-Through Curve

FWX 1-30A: 250V (14 x 51mm)

Time-Current Curve

Data Sheet: 35785302

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

228

High Speed Fuses

Ferrule — FWH 500V: 0.25-30A

FWH (6 x 32mm)

Specifications
Description:

Ferrule style high

speed fuses.

Dimensions:

See dimensions

illustrations.

Ratings:

Volts: — 500Vac (0.25-6.3A)

500Vdc (2-5A)

Amps: — 0.25-30A

IR: — 50kA at ≥ 20% pf (0.25-20A)

— 20kA at ≥ 20% pf (25-30A)

Agency Information:

CE, UL Recognition JFHR2.E91958

0.25-30A, CSA Component Acceptance file Class 1422-30,
1422-90 (53787) 0.25-7A

Opening Times

Amp Ratings

150%

200%

300%

0.25-7

> 30 min

< 30 min

≤ 10 sec

10-30

< 30 min

< 30 min

≤ 10 sec

31.8

(1.25")

3.2

(0.125")

6.4

(0.25")

Dimensions - mm (inches)

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Watts

Numbers

Size

RMS-Amps

Pre-arc

at 500V

Loss

FWH-.250A6F

0.25*

0.01

0.05

2.7

FWH-.500A6F

0.5*

0.05

0.25

1.2

FWH-001A6F

1*

0.4

2

1.7

FWH-002A6F

2*

1.3

3.5

3.2

FWH-3.15A6F

3.15*

3.1

7.7

2.9

FWH-005A6F

5*

15

40

2.1

FWH-6.30A6F 6 x 32mm

6.3*

36

90

2.3

FWH-007A6F

(

1

4

” x 1

1

4

”)

7*

50

125

2.5

FWH-010A6F

10**

9.9

139

2.86 

FWH-12.5A6F

12.5**

20

60

3.53

FWH-015A6F

15**

44

146

3.08

FWH-016A6F

16**

48

177

4.48

FWH-020A6F

20**

75

259

4.26

FWH-025A6F

25**

126

345

FWH-030A6F

30**

145

430

*300% minimum opening current at rated voltage.
**200% minimum opening current at rated voltage.
• Consult Bussmann for DC ratings.
• See accessories on page 243.

Features and Benefits

• Excellent cycling capability and DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss in a compact size
• Used with finger-safe holders/blocks

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Data Sheet: 720038

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

229

High Speed

Fuses

Ferrule — FWH 500V: 0.25-30A

.2

.4

.6

.8

10

0

2

2

4

6

8

2

10

1

2

4

6

8

2

10

2

Prospective Current In Amps RMS

2

4

6

2

6

4

2

6

4

2

6

4

2

6

4

2

6

4

10

–1

10

–2

4x10

–3

10

0

10

1

10

2

10

3

10

4

V

irtual Pre-Arcing 

T

ime In Seconds

FWH-002A6F

FWH-3.15A6F

FWH-005A6F

FWH-6.30A6F

FWH-001A6F

FWH-.500A6F

FWH-.250A6F

FWH-007A6F

FWH 0.25-7A: 500V (6 x 32mm)

Time-Current Curve

FWH 10-30A: 500V (6 x 32mm)

Time-Current Curve

Data Sheet: 35785256

Data Sheet: 50955

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

230

High Speed Fuses

Data Sheet: 720008

Dimensions - mm (inches)

50.8

(2.000")

15.5

(0.610")

14.3

(0.563")

FWH (14 x 51mm)

Specifications
Description:

Ferrule style high

speed fuses.

Dimensions:

See Dimensions

illustration.

Ratings:

Volts: — 500Vac

Amps: — 1-30A

IR: — 200kA RMS Sym.

— 50kA @500Vdc

Agency Information:

CE, UL Recognition 1- 30A & CSA

Component Acceptance file Class 1422-30, (53787) on: 
5 - 30A. 

Electrical Characteristics

Total Clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor
of 15% are given in the 
electrical characteristics. For
other voltages, the clearing
I

2

t is found by multiplying by

correction factor, K, given as
a function of applied working
voltage, Eg, (rms).

500

400

250

100

1.5

1.0

0.5

0.3

0.2

0.15

E

g

K

Arc Voltage

This curve gives the peak
arc voltage, UL, which may

appear across the fuse 
during its operation as a
function of the applied 
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of the
power losses at load 
currents lower than the
rated current. The correction
factor, Kp, is given as a

function of the RMS load
current, Ib, in % of the rated

current.

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Watts

Numbers

Size

RMS-Amps

Pre-arc

at 500V

Loss

FWH-1A14F

14 x 51mm

1

FWH-2A14F

(

9

16

” x 2”)

2

FWH-3A14F

3

2.3

FWH-4A14F

4

FWH-5A14F

5

1.6

6.4

1.5

FWH-6A14F

6

1.6

6.4

1.5

FWH-10A14F

10

3.6

13

4

FWH-12A14F

12

FWH-15A14F

15

10

40

5.5

FWH-20A14F

20

26

96

6

FWH-25A14F

25

49

191

7

FWH-30A14F

30

58

232

9

• Watts loss provided at rated current.
• See accessories on page 243.

Features and Benefits

• Excellent cycling capability and dc performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss in a compact size
• Used with finger-safe holders/blocks

Typical Applications

• DC common bus
• DC drives
• Power converters/rectifiers
• Reduced voltage starters

U

L

2.0

1.6

1.2

10

3

800

600

500

400

300

100

400

300

200

500

E

g

-

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

Ferrule — FWH 500V: 1-30A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

231

High Speed

Fuses

Ferrule — FWH 500V: 1-30A

Peak Let-Through Curve

2

4

6

8

10

1

2

2

4

6

8

2

10

2

2

4

6

8

10

3

2

4

6

2

6
4

2

6
4

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

FWH-5A14F
FWH-10A14F
FWH-15A14F
FWH-20A14F
FWH-25A14F
FWH-30A14F

V

irtual Pre-Arcing 

T

ime In Seconds

Prospective Current In Amps RMS

10

3

10

0

10

1

10

4

10

2

10

–4

10

–3

10

–2

10

–1

FWH 1-30A: 500V (14 x 51mm)

Time-Current Curve

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Through Current

2

4

2

6

6

4

2

6

4

2

4

6

2

4

6

2

4

6

2

4

6

10

1

10

2

10

3

10

4

10

1

10

2

10

3

10

4

10

5

FWH-5A14F

FWH-10A14F

FWH-15A14F

FWH-20A14F

FWH-25A14F

FWH-30A14F

2

Data Sheet: 35785298

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

232

High Speed Fuses

Ferrule — FWC 600V: 6-32A

Dimensions - mm (in)

38.1

(1.500")

9.5

(0.375")

10.3

(0.406")

FWC (10 x 38mm)

Specifications
Description:

Ferrule style high

speed fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 600Vac/700Vdc (6-25A)

600Vac (30-32A)

Amps: — 6-32A

IR: — 200kA RMS Sym.

— 50kA @ 700Vdc (6-25A)

Agency Information:

CE, UL Recognition JFHR8.E91958

6-32A. & CSA Component Acceptance file Class 1422-30,
(53787) on (6-32A)

Electrical Characteristics

Total Clearing I

2

t

The total clearing I

2

t at rated

voltage and at power factor
of 15% are given in the 
electrical characteristics. For
other voltages, the clearing
I

2

t is found by multiplying by

correction factor, K, given as
a function of applied working

voltage, Eg, (rms).

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power 
factor of 15%.

Power Losses

Watts loss at rated 
current is given in the
electrical characteristics.
The curve allows the 
calculation of the power
losses at load currents
lower than the rated 
current. The correction
factor, Kp, is given as a

function of the RMS load
current, Ib, in % of the

rated current.

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Watts

Numbers

Size

RMS-Amps

Pre-arc

at 600V

Loss

FWC-6A10F

6

4

30

1.5

FWC-8A10F

8

6

50

2.0

FWC-10A10F

10

9

70

2.5

FWC-12A10F

10 x 38mm

12

15

120

3.0

FWC-16A10F

(

13

32

” x 1

1

2

”)

16

25

150

3.5

FWC-20A10F

20

34

260

4.8

FWC-25A10F

25

60

390

6.0

FWC-30A10F

30

95

600

7.5

FWC-32A10F

32

95

600

7.5

• Watts loss provided at rated current.
• See accessories on page 243.

Features and Benefits

• Excellent cycling capability and DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss in a compact size
• Used with finger-safe holders/blocks

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

500

600

400

250

100

1.5

1.0

0.5

0.3

0.2

0.15

E

g

K

U

L

2.0

1.6

1.2

10

3

800

600

500

400

300

400

300

200

500      600

E

g

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

Data Sheet: 720011

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

233

High Speed

Fuses

Ferrule — FWC 600V: 6-32A

10

3

10

4

10

2

10

–1

10

–2

10

–3

10

–4

10

1

2

2

4

6

8

2

10

2

2

4

6

8 10

3

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

FWC-10A10F

FWC-30A10F & FWC-32A10F

FWC-20A10F
FWC-25A10F

FWC-12A10F
FWC-16A10F

 FWC-8A10F

 FWC-6A10F

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Through Current

2

4

2

6

6

4

2

6

4

2

4

6

2

4

6

2

4

6

2

4

6

10

1

10

2

10

3

10

4

10

1

10

2

10

3

10

4

10

5

FWC-6A10F

FWC-8A10F

FWC-10A10F

FWC-12A10F

FWC-16A10F

FWC-20A10F

FWC-25A10F

FWC-30A10F & FWC-32A10F

Peak Let-Through Curve

FWC 6-32A: 600V (10 x 38mm)

Time-Current Curve

Data Sheet: 35785306

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

234

High Speed Fuses

Ferrule — FWP 690V/700V (IEC/UL): 1-50A,
Striker Optional

Dimensions - mm (in)

51 (2.00")

59 (2.323")

13 (0.511")

14.3

(0.563")

5 (0.197")

FWP (14 x 51mm)

Specifications
Description:

Ferrule style high

speed fuses with and without 
indicating striker.

Dimensions:

See dimensions

illustrations.

Ratings:

Volts: — 690Vac (IEC)

— 700Vac (UL)

— 800Vdc (5-50A)

Amps: — 1-50A

IR: — 200kA RMS Sym.

— 50kA @800Vdc

Agency Information:

CE, UL Recognition JFHR2.E91958,

CSA Component Acceptance file Class 1422-30, 1422-90
(53787) for versions without indicator only. Designed and 
tested to IEC 60269: Part 4.

Electrical 

Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied working
voltage, Eg, (rms).

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Catalog Numbers

Rated

I

2

t (A

2

Sec)

Catalog

Current

Minimum

Clearing At

Watts

Numbers

Size

RMS-Amps

Melting

Rated Voltage

Loss

Without Striker
FWP-1A14F

1

—        

FWP-2A14F

2

FWP-2.5A14F

2.5

FWP-3A14F

3

FWP-4A14F

4

FWP-5A14F

14 x 51mm

5

1.6

11.0

1.5

FWP-10A14F

(

9

16

" x 2")

10

3.6

38.5

4

FWP-15A14F

15

8.6

70

5.5

FWP-20A14F

20

26.0

230

6

FWP-25A14F

25

46.5

375

7

FWP-30A14F

30

58

485

9

FWP-32A14F

32

68

600

7.6

FWP-40A14F

40

84

750

8

FWP-50A14F

50

200

1800

9

With Striker*
FWP-10A14FI

10

3.6

38.5

4

FWP-15A14FI

15

8.6

70

5.5

FWP-20A14FI

14 x 51mm

20

26.0

230

6

FWP-25A14FI

(

9

16

” x 2”)

25

46.5

375

7

FWP-30A14FI

30

58

485

9

FWP-32A14FI

32

68

600

7.6

FWP-40A14FI

40

84

750

8

FWP-50A14FI

50

200

1800

9

*Striker range is 600Vdc only
• Watts loss provided at rated current.
• See accessories on page 243.

Features and Benefits

• Excellent cycling capability and DC performance
• Low arc voltage and low energy let-through (

I2

t)

• Low watts loss in a compact size
• Used with finger-safe holders/blocks

U

L

1.4

1.2

10

3

6

8
7

9

5

4

3

200

300

400

500

600

700

E

g

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

K

1.4

1.2

1.0

0.6

0.8
0.7

0.9

0.5

0.4

0.3

200

300

400

500

600

700

E

g

1)

2)

1) 5-30A Range
2) 32-50A Range

50.8

(2.000")

15.5

(0.610")

14.3

(0.563")

With Striker

Without Striker

FWP with

striker option.

Electrical Characteristics

Data Sheet: 720025

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

235

High Speed

Fuses

Ferrule — FWP 690V/700V (IEC/UL): 1-50A,
Striker Optional

10

3

10

2

10

–1

10

–2

10

–3

10

–4

FWP-10A14F
FWP-15A14F
FWP-20A14F

FWP-5A14F

FWP-50A14F

FWP-30A14F
FWP-32A14F
FWP-40A14F

FWP-25A14F

2

4

6

8

10

1

2

2

4

6

8

2

10

2

2

4

6

8

10

3

2

4

6

2

6
4

10

0

2

6
4

10

1

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

10

4

Prospective Short-Circuit Current Symmetrical RMS

Peak Let-Through Current

2

4

2

6

6

4

2

6

4

2

4

6

2

4

6

2

4

6

2

4

6

10

1

10

2

10

3

10

4

10

1

10

2

10

3

10

4

10

5

FWP-5A14F

FWP-10A14F

FWP-15A14F

FWP-20A14F

FWP-25A14F

FWP-30A14F

FWP-32A14F

FWP-40A14F

FWP-50A14F

2

Peak Let-Through Curve

Without Striker
FWP 5-50A: 660V/700V (14 x 51mm)

Time-Current Curve

Data Sheet: 35785307

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

236

High Speed Fuses

Ferrule — FWP 690V/700V (IEC/UL):
20-100A, Striker Optional

Dimensions - mm (in)

66 (2.598")

58 (2.283")

16 (0.630"

22.2 (0.874")

5

(0.197")

FWP (22 x 58mm)

Specifications
Description:

Ferrule style high

speed fuses with and without
indicating striker.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 690Vac (IEC)

— 700Vac (UL)

— 500Vac 

— 500Vdc (20-100A)

Amps: — 20-100A

IR: — 200kA RMS Sym.

— 50kA @ 500Vdc

Agency Information:

CE, UL Recognition JFHR2.E91958,

CSA Component Acceptance file Class 1422-30, 1422-90
(53787)

Electrical 

Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is

given as a function of the
RMS load current, Ib, in %

of the rated current.

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Minimum

Clearing At

Watts

Numbers

Size

RMS-Amps

Melting

Rated Voltage

Loss

Without Striker
FWP-20A22F

20

19.0

260

5

FWP-25A22F

25

34.0

410

6

FWP-32A22F

22 x 58mm

32

53.5

605

8

FWP-40A22F

(

7

8

" x 2

9

32

")

40

68

750

9

FWP-50A22F

50

135

1600

9.5

FWP-63A22F

63

280

3080

11

FWP-80A22F

80

600

6600

13.5

FWP-100A22F

100*

1100

12500

16

With Striker
FWP-20A22FI

20

19.0

260

5

FWP-25A22FI

25

34.0

410

6

FWP-32A22FI

22 x 58mm

32

53.5

605

8

FWP-40A22FI

(

7

8

" x 2

9

32

")

40

68

750

9

FWP-50A22FI

50

135

1600

9.5

FWP-63A22FI

63

280

3080

11

FWP-80A22FI

80

600

6600

13.5

FWP-100A22FI

100*

1100

12500

16

*IEC/UL Voltage rating 690/700

Features and Benefits

• Excellent cycling capability and DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss in a compact size
• Used with finger-safe holders/blocks

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

K

1.4

1.2

1.0

0.6

0.8
0.7

0.9

0.5

0.4

0.3

200

300

400

500

600

700

E

g

U

L

1.4

1.2

10

3

6

8
7

9

5

4

3

200

300

400

500

600

700

E

g

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

Data Sheet: 720026

58.0

(2.283")

15.0

(0.591")

22.2

(0.875")

With Striker

Without Striker

FWP with

striker

option.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

237

High Speed

Fuses

Ferrule — FWP 690V/700V (IEC/UL): 20-100A,
Striker Optional

10

1

2

2

4

6

8

2

10

2

2

4

6

8

10

3

2

4

6

2

6
4

2

6
4

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

10

1

10

0

10

–1

10

–2

10

–3 

10

–4

10

2

10

3

10

4

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

FWP-20A22F
FWP-25A22F
FWP-32A22F
FWP-40A22F

FWP-50A22F
FWP-63A22F
FWP-80A22F
FWP-100A22F

10

4

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

2

6

4

2

6

4

2

4

6

2

4

6

2

4

6

10

2

10

3

10

2

10

3

10

4

10

5

FWP-20A22F

FWP-25A22F

FWP-32A22F

FWP-40A22F

FWP-50A22F

FWP-63A22F

FWP-80A22F

FWP-100A22F

2

Peak Let-Through Curve

Without Striker
FWP  20-100A: 660V/700V (22 x 58mm)

Time-Current Curve

Data Sheet: 35785291

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

238

High Speed Fuses

Ferrule — FWK 750V: 5-60A

Dimensions - mm (in)

Fig. 1: 5-30A

146.05

(5.75")

25.4

(1")

20.64

(0.813")

Fig. 2: 35-60A

127.0

(5.000")

16.0

(0.630")

20.5

(0.807")

FWK 5-30A (20 x 127mm

35-60A (25 x 146mm)

Specifications
Description:

Ferrule style high speed fuses.

Dimensions:

See Dimensions illustrations.

Ratings:

Volts: — 750Vac

— 750Vdc (Time constant = 10-15mS)

Amps: — 5-60A

IR: — 45kA RMS Sym.

Agency Information:

CE

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Numbers

Size

RMS-Amps

Pre-arc

at 750Vdc

FWK-5A20F

5

8.5

16

FWK-8A20F

8

50

100

FWK-10A20F

10

95

200

FWK-15A20F

20 x 127mm

15

100

240

FWK-20A20F

(

13

16

” x 5”)

20

125

315

FWK-25A20F

25

400

1100

FWK-30A20F

30

800

2600

FWK-35A25F

35

1300

4300

FWK-40A25F

25 x 146mm

40

1600

5300

FWK-50A25F

(1” x 5

3

4

”)

50

3100

12000

FWK-60A25F

60

5900

24000

Recommended fuseholders for 20x127, -2, -3
Recommended fuseclips for 20x127, 1A1837
Recommended fuseclips for 25x146, A3354705

Features and Benefits

• Excellent cycling capability and DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss in a compact size
• Used with finger-safe holders/blocks

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

Data Sheet: 720039

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

239

High Speed

Fuses

Ferrule — FWK 750V: 5-60A

2

4

6

8

10

1

2

2

4

6

8

2

10

2

2

4

6

8

10

3

2

4

6

2

6

4

2

6

4

2

6

4

2

6

4

2

6

4

10

±

1

10

±

2

4x10

±

3

10

0

10

1

10

2

10

3

10

4

FWK-15A20F

FWK-20A20F

FWK-25A20F

FWK-30A20F

FWK-40A25F

FWK-50A25F

FWK-60A25F

 FWK-5A20F

 FWK-8A20F

FWK-10A20F

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

FWK 750V: 5-30A (20 x 127mm)

35-60A (25 x 146mm)

Time-Current Curve

High Speed Fuses

Data Sheet: 720028

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

240

High Speed Fuses

Data Sheet: 35785031

Ferrule — FWJ 1000V: 20-30A

Dimensions - mm (in)

66.7

(2.626")

15.9

(0.625")

14.5

(0.571")

FWJ (14 x 67mm)

Specifications
Description:

Ferrule style high

speed fuses.

Dimensions:

See dimensions

illustration.

Ratings:

Volts: — 1000Vac/800Vdc

Amps: — 20-30A

IR: — 25kA RMS Sym.

— 20kA @ 800Vdc

Agency Information:

CE, UL Recognized JFHR2.E91958

Electrical 

Characteristics

Total Clearing I

2

t

The total clearing I

2

t at

rated voltage and at power
factor of 15% are given in
the electrical 
characteristics. For other
voltages, the clearing I

2

t is

found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).

Arc Voltage

This curve gives the peak
arc voltage, UL, which

may appear across the
fuse during its operation
as a function of theapplied
working voltage, Eg, (rms)

at a power factor of 15%.

Power Losses

Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The 
correction factor, Kp, is
given as a function of the
RMS load current, Ib, in %

of the rated current.

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Watts

Numbers

Size

RMS-Amps

Pre-arc

at 1000V

Loss

FWJ-20A14F

14 x 67mm

20

25

220

9

FWJ-25A14F

(

9

16

” x 2

5

8

”)

25

33

350

11

FWJ-30A14F

30

52

450

14

• Watts loss provided at rated current.
• See accessories on page 243.

Features and Benefits

• Excellent cycling capability and DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss in a compact size
• Used with finger-safe holders/blocks

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters

1000

800

500

200

1.5

1.0

0.5

0.3

0.2

0.15

Eg

K

2000

1600

1200

800

400

200

600

1000 1400 1800

U

L

E

g

K

p

1.0
0.8

0.4

0.5

0.6

0.3

0.2

0.1

30 40 50

60

70

80 90 100%

I

b

Fuseclips:

• Catalog Number: 5591 (see data sheet 2132)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

241

High Speed

Fuses

Ferrule — FWJ 1000V: 20-30A

FWJ-20A14F
FWJ-25A14F
FWJ-30A14F

10

1

2

2

4

6

8

2

10

2

2

4

6

8 10

3

2

4

6

2

6
4

2

6
4

2

6
4

2

6
4

2

6
4

6
4

2

6

2

4

10

–4

10

0

10

1

10

–1

10

–2

10

–3

10

2

10

3

10

4

Prospective Current In Amps RMS

V

irtual Pre-Arcing 

T

ime In Seconds

FWJ 20-30A: 1000V (14 x 67mm)

Time-Current Curve

Prospective Short-Circuit Current Symmetrical RMS

P

eak Let-Through Current

2

4

2

6

6

4

2

6

4

2

4

6

2

4

6

2

4

6

2

4

6

10

1

10

2

10

3

10

4

10

1

10

2

10

3

10

4

10

5

FWJ-20A14F

FWJ-25A14F

FWJ-30A14F

2

Peak Let-Through Curve

Data Sheet: 35785315

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

242

High Speed Fuses

Ferrule — FWS/FWL 1000Vdc: 2-30A

Dimensions - mm (in)

127.0

(5.000")

16.0

(0.630")

20.5

(0.807")

Indicating Version – Dimensions - mm (in)

127.0

(5.000")

16.0

(0.630")

20.5

(0.807")

2.0

(0.079")

2.0

8.0

(0.315")

FWL/FWS 2-30A: 1000Vdc 2-30A 
(20 x 127mm)

Time-Current Curve

FWS 2-15A (20 x 127mm)
FWL 20-30A (20 x 127mm)

Specifications
Description:

Ferrule style full range

fuses.

Dimensions:

See dimensions 

illustrations.

Ratings:

Volts: — 1200Vac (FWL 20-30A)

— 1400Vac (FWS 8-15A)

— 2100Vac (FWS 2-6A)

— 1000Vdc (FWL/FWS 2-30)

Amps: — 2-30A

IR: — 45kA RMS Sym.

— 30kA @ 1000Vdc

Agency Information:

CE, IEC 60077

Catalog Numbers

Electrical Characteristics

Rated

I

2

t (A

2

Sec)

Catalog

Current

Clearing

Watts

Numbers

Size

RMS-Amps

Pre-arc

at 1000Vdc

Loss

FWS-2A20F

2

0.8

2.4

4.4

FWS-6A20F

6

27

81

6.7

FWS-8A20F

20 x 127mm

8

64

192

7.6

FWS-10A20F

(

13

16

” x 5”)

10

118

277

3.0

FWS-12A20F

12

170

380

3.4

FWS-15A20F

15

209

500

5.0

FWL-20A20F

20 x 127mm

20

675

1550

5.9

FWL-25A20F

(

13

16

” x 5”)

25

1200

2760

6.5

FWL-30A20F

30

1850

4300

7.5

• ADD “I” to catalog number for indicating version.
• Enclosed finger-safe fuse holder – CH127
• See accessories on page 243.
• Watts loss provided at rated current.

Features and Benefits

• Excellent cycling capability and DC performance
• Low arc voltage and low energy let-through (I

2

t)

• Low watts loss in a compact size
• Used with finger-safe holders/blocks

Typical Applications

• DC Common bus
• DC Drives
• Power converters/rectifiers
• Reduced voltage starters
• Traction aux circuits
• Capacitor protection

Data Sheet: 720040

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

243

High Speed

Fuses

Ferrule Fuse Accessories

Data Sheet: 2053

Fuse Holders

Specifications
Catalog Symbol:

CH Series

Description:

DIN-Rail mount

fuse holders

Agency Information:

UL File E14853, Guide IZLT
Listed, IZLT2 Recognized
CSA: File 47235, CHPV and
CHM - Class 6225-30, 
CHCC - Class 6225-01

Ratings:

600V/30A (UL)
690V/32A (IEC)

Features and Benefits

• Finger-safe design - No exposed contacts
• DIN-Rail mount (35mm) - Fits standard mounting rails
• Optional open fuse indication lights tells fuse status at a

glance

• Handle/fusepuller easily installs and removes fuses
• Available in single and multi-pole configurations
• Wire ready lugs and spade terminal connections save 

installation time

• CE marking
• Available up to 1000Vdc
• PLC device available for remote monitoring

Typical Applications

• Switchboard panel, control consoles, small motors, 

transformers, and similar applications

Recommended Cooper Bussmann Fuse Types

Class CC North American Class CC Fuses - LP-CC, 

FNQ-R, KTK-R

10 x 38

North American Midget Fuses - FNQ, KTK, AGU,

BAF, BAN, FNM, FWA, FWC, & PV

14 x 51

FWX, FWH, FWP & NON

22 x 58

FWP

See pages 274-280 for CH Series fuse holder information.

Fuse Blocks

Specifications
Catalog Symbol:

J70100,
J70032

Description:

Fuse blocks 

for 22x58mm & 14x51mm
fuses. 

Ratings:

Volts: — 700Vac/dc

Amps: — 32-100A

Withstand: — 200kA RMS Sym.

Agency Information:

CE, UL Recognized, Guide IZLT2,

File E14853

Flammability Rating:

UL 94V0

Catalog Numbers

Catalog

Fuse

Max Wire

Numbers

Size

Amps

Poles

Size

Terminations

J70032-1CR

32

1

#2 

J70032-2CR

32

2

#2

Box Lug w/

J70032-3CR

32

3

#2

Retaining Clip

J70100-1CR

100

1

#2

J70100-2CR

22x58

100

2

#2

J70100-3CR

100

3

#2

Data Sheet: 1211

Box Lug w/

Retaining Clip

14x51

22x58

High Speed Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

244

Faster lead-time.
Better protection.
More energy efficient.

High speed fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

245

Application Data

The standard range of fuses for low voltage industrial and
general purpose applications meet the requirements of 
BS 88 and IEC 60269. By using advanced fuse technology, 
current ratings up to 400A have compact dimensions, but
retain standard dimensional and performance requirements.
These designs are for 315/240V systems. The standard
range of fuses are available from 2-1250A in the following
tag forms: Offset Blade - Offset Bolted - Center Bolted.

Supplementary ranges cover applications up to 660Vac and
500Vdc including those with nonstandard tag fixings.

Bussmann fuses are manufactured under quality systems
independently assessed to BS 5750 (ISO 9002) and 
appropriate ratings carry the ASTA 20 endorsement.

Selecting fuses is relatively simple and effective. The
following notes cover the majority of applications. For further
information contact our Application Engineers at toll free
phone: 855-287-7626 (855-BUSSMANN).

Circuit Loading

The current rating of the fuse should not be less than the full
load current of the circuit. The circuit should be so designed
that small overloads of long duration will not be of frequent
occurrence.

Cable Ratings & Protection

There is an increasing move away from 70°C PVC insulation
to materials that are more environmentally friendly, for
example 90°C XLPE. The ratings of fusegear, switches,
accessories, etc. are generally based upon the equipment
being connected to conductors intended to be operated at a
temperature not exceeding 70°C in normal service.

In view of the above, it is recommended that the practice of
designs based upon conductor temperatures of 70°C be
regarded as the norm. The equipment manufacturer should
be consulted to ascertain the reduction of nominal current
rating of the equipment if conductor temperatures exceeding
70°C are used. In addition, an overriding factor is often
voltage drop.

Fuses with gG characteristics protect associated cables
against both overload and short-circuit current, provided that
the current rating of the fuse 1N is equal or less than the

current carrying capacity of the cable 1z.
In motor circuits, the motor starter will provide the overload
protection and the fuses will provide the short-circuit
protection. The maximum fuse size that can be used
depends upon the type of cable used and is determined
using the appropriate K factor. The following table gives the
maximum sizes of fuses that are recommended for two
popular cables with copper conductors, 70°C PVC (K = 115)
and 90°C thermosetting (K = 143).

Section Contents

Page

Application Data . . . . . . . . . . . . . . . . . . . . . 245-246

CSA Type P and Type D fuses 

(CDS, CDN & PON) . . . . . . . . . . . . . . . . . . . . . . . . . . . .247

Tron

HRC Form II Class C fuses 

(CGL Form II Class C) . . . . . . . . . . . . . . . . . . . . . . . . . . 248

HRCI Industrial ceramic body fuses (CIF21 HRCI-CA &

CIF06 HRCI-CB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249

HRCI-J Fast-acting fuses (CJ HRCI-J) . . . . . . . . . . . . . . . 250

HRCI-Miscellaneous Type K fuses (CIH, CIK & 

CIL HRCI-MISC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251

HRC Form II current-limiting fuses  . . . . . . . . . . . . . . . . . .252

BS 88 British Standard low voltage fuses (SSD, NSD, 

ESD & STD, NITD, AAO, BAO, OSD, CEO, 
DEO BS 88 Part 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253

BS 88 British Standard low voltage fuses (AC, AD, BC, 

BD, CD, DD, ED, EFS & EF, FF, FG, GF, GG, 
GH BS 88) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .254

DIN Style Type D (D16, D27, D33, D125 Type D)  . . . . . . 255

Neozed low voltage fuses (NZ01, NZ02 Type D0) . . . . . . 255

NH HRC Fuses  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256-259

Class gG/gL IEC Industrial ferrule fuses (C08G, C08M,

C10G, C10M, C14G, C14M, C22G, C22M) . . . . . . . . . . 260

Class aM IEC Industrial ferrule fuses (C08M, C10M, 

C14M, C22M) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .261

Class aM & gG/gL IEC Industrial ferrule fuses with striker
(C14G_S, C22G_S, C14M_S, C22M_S)  . . . . . . . . . . . . . 262

HRC fuse holders

CAMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .263

SAFEloc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .263

IEC & British

Fuses

IEC & British Standard Fuses

IEC and British Standard Fuses

Scan this tag to get the

latest product information for 

IEC and British Standard Fuses.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

246

IEC & British Standard Fuses

Application Data for BS Low Voltage Fuses 

Max. Fuse Rating (amps)

Cable Size (mm

2

)

K = 115

K = 143

1

16

16

1,5

20

25*

2.5

32*

32*

4

50*

50*

6

63*

63*

10

100*

125*

16

125*

160*

25

200*

250*

35

315*

355*

50

400*

500

70

560

630

95

710

800

120

800

1000

* Extended Motor Circuit dual ratings can be used.

Protection Against Electrical Shock

For a TN System, a disconnecting time not exceeding 5s is
permitted for a distribution circuit. The maximum values of
earth fault loop impedance (Zs) of 240V for Bussmann gG
fuses to BS 88: Parts 2 and 6 are:

Rating (A) Zs (Ohms) Rating (A) Zs (Ohms)  Rating (A) Zs (Ohms)

6

14

50

1.1

250

0.16

10

7.7

63

0.86

315

0.13

16

4.3

80

0.60

400

0.096

20

3.0

100

0.44

500

0.073

25

2.4

125

0.35

630

0.054

32

1.9

160

0.27

800

0.044

40

1.4

200

0.20

Ambient Temperature

The derating, in terms of current, of 0.5% per °C above an
ambient of 35°C is recommended.

Interrupting Rating

The standardized interrupting rating values are 80kA for
voltages of 415Vac and above, and 40kA for DC 
applications. The 240Vac designs have an interrupting rating
of 50kA.

Coordination Ratio

All fuses to BS 88 Parts 2 and 6 will give a coordination ratio
of 2:1; and for most practical situations a ratio of 1.6:1 (two
steps in the R10 series). Example: an upstream fuse rated at
160A will coordinate with a downstream fuse rated at 100A.

Current and Energy Limitation

The range of fuses have pre-arcing I

2

t values towards the

bottom limits of BS 88 Parts 2 and 6. This ensures excellent
current and energy limitation. They also have lower power
losses at rated current. This assists in the appropriate
interchangeability with other makes of fuses.

Transformers

When fuses are used on the primary side of transformers,
the normal fuse current rating should be at least twice the
nominal transformer primary current.

Fluorescent Lighting

The normal fuse current rating should be at least twice the
normal full load current of the maximum number of lights to
be simultaneously switched.

Capacitor Circuits

For power factor correction in capacitor circuits, the fuse
should be chosen with a current rating greater than 1.5 times
the rated capacitor current. This takes into account the high
inrush current, circuit harmonics and capacitor tolerances.

Motor Circuits

In motor circuits, the fuse has to withstand the motor's
starting current and often requires a higher rating than the
motor's full load current. Coordination recommendations are
made by the manufacturers of motor starters in accordance
with IEC 60947-4-1. To get Type 2 coordination with fuses,
tests are performed with the latest gG or gM fuses to BS 88
or IEC 60269 that have pre-arcing I

2

t values towards the 

bottom of specified limits. This means that Bussmann fuses
are suitable to provide Type 2 coordination.

Extended dual ratings of motor circuit protection fuses with
gM characteristics are available in most popular fuse sizes to
extend the use of associated equipment with appropriate
economies. In the majority of applications, gG fuses are
used. It is not essential to use gM fuses for motor circuit
protection, they simply extend the utilization of standard
equipment.

Below is a table of recommended fuses at 415V. In most
applications, the run-up time is less than 5 seconds and duty
is infrequent - no more than twice per hour. The next larger
rating should be used for more demanding applications.

Direct On-line

Asst. Start

Standard

Motor Circuit 

Standard

Rating Motor

(gG)

(gM)

(gG)

kW

A

A

A

A

0.25

0.8

4

-

2

0.37

1.1

4

-

2

0.55

1.5

6

-

4

0.75

2.0

6

-

4

1.1

3 0

10

-

6

1.5

3.6

16

-

0 1

2.2

5.0

16

-

0 1

3.0

6.5

20

-

6 1

4.0

8.4

20

-

6 1

5.5

11.0

25

20M25

2 20

7.5

15.0

40

32M40

25

11.0

20.0

50

32M50

32

15.0

27.0

63

32M63

40

18.5

33.0

80

63M80

50

22.0

38.0

80

63M80

50

30.0

54.0

100

63M100

80

37.0

66.0

125

100M125

80

45.0

79.0

160

100M160

100

55.0

98.0

160

100M160

100

75.0

135.0

250

200M250

160

90.0

155.0

250

200M250

160

110.0

185.0

315

200M315

200

132.0

220.0

355

315M400

250

150.0

250.0

355

315M400

315

185.0

310.0

450

400M500

355

200.0

335.0

500

4 00M500

400

225.0

375.0

560

-

400

250.0

415.0

560

-

450

280.0

460.0

630

-

500

335.0

562.0

710

-

630

355.0

596.0

800

-

710

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

247

CSA Type P and Type D Fuses

IEC & British

Fuses

Catalog Numbers

Basic Catalog

Dimensions in (mm)

Number

Amp

A

B Max

C Min

D Min

E

and Volts

Ratings

Overall

Diameter

Blade Length

Barrel Length

Blade Thickness

Blade Width

1-30

2.0 (50.8)

0.56 (14.3)

35-60

3.0 (76.2)

0.81 (20.6)

CDN/PON 250Vac

70-100

5.88 (149.4)

1.0 (25.4)

0.13 (3.2)

0.75 (19.1)

110-200

7.3 (185.4)

1.38 (34.9)

4.13 (104.8)

0.19 (4.8)

1.13 (28.6)

225-400

8.63 (219.2)

1.88 (47.6)

4.63 (117.5)

0.25 (6.4)

1.63 (41.3)

450-600

10.38 (263.7)

2.25 (57.2)

5.19 (131.8)

0.25 (6.4)

2 (50.8)

1-30

5.0 (127.0)

0.81 (20.6)

35-60

5.5 (139.7)

1.06 (27.0)

CDS 600Vac

70-100

7.88 (200.2)

1.0 (25.4)

0.13 (3.2)

0.75 (19.1)

110-200

9.63 (244.6)

1.38 (34.9)

6.13 (115.6)

0.19 (4.8)

1.13 (28.6)

225-400

11.63 (295.4)

1.88 (47.6)

7.13 (118.1)

0.25 (6.4)

1.63 (41.3)

450-600

13.38 (339.9)

2.25 (57.2)

8.19 (208.0)

0.25 (6.4)

2 (50.8)

To Order

To order, specify Basic Catalog Number and amp rating. Example: CDN-30

E

B

F

A
D

C

Knife Blade—70 through 600A 

A

B

Ferrule Design—1 through 60A 

Data Sheet: 4126

CDS, CDN & PON Type P & D

Specifications
Description:

CSA time-delay Type D & P

fuses.

Dimensions:

See Catalog Numbers table

and Dimensions illustration.

Ratings:

Volts: — 250Vac (CDN & PON)

— 600Vac (CDS)

Amps: — 10-600A

IR: — 10kA minimum

Agency Information:

CE, CSA Certified to C22.2 No. 59.1.

Features and Benefits

• Economical fuse in a variety of ratings for applications not

requiring time-delay.

Typical Applications

• Lighting, heating and other circuits not subject to temporary

surges and where available short-circuit current are
relatively low.

Basic Catalog Numbers

Time-Delay CSA Type “D” Fuses

Catalog

Amp

Numbers

Volts

Ratings

Below 10A use FRN-R 10, 12, 15, 20, 25, 30,
35, 40, 45, 50, 60, 70, 80, 90, 100

CDN

250Vac

110, 125, 150, 175, 200, 225, 250, 300, 350, 400,
450, 500, 600
Below 10A use FRS-R 10, 12, 15, 20, 25, 30,
35, 40, 45, 50, 60

CDS

600Vac

70, 80, 90, 100, 110, 125, 150, 175, 200,
225, 250, 300, 350, 400, 450, 500, 600

One-Time CSA Type “P” Fuses

Catalog

Amp

Number

Volts

Ratings

PON

250Vac

15, 20, 25, 30, 35, 40, 45, 50, 60

Dimensions

IEC & British Standard Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

CGL Form II Class C

Specifications
Description:

Current-limiting HRCII-C fuses

designed to withstand inrush currents on
typical motor start-ups while offering high
current limitation in the short-circuit region.

Dimensions:

See Dimensions illustrations.

Ratings:

Volts: — 600Vac/250Vdc (1-30A)

Amps: — 1-600A

IR: — 200kA (40,000A DC)

Agency Information:

CE, CSA Certified,

C22.2 No. 106.

Features and Benefits

• Close sizing to loads allows using smaller and less costly

switches

• Provides a higher degree of short-circuit protection
• Helps protect motors against burnout from overloads

Typical Applications

• For use in circuits subject to surge currents such as those

caused by motors, transformers and other inductive loads

Catalog Numbers (-Amps)

CGL-1

CGL-40

CGL-175

CGL-2

CGL-45

CGL-200

CGL-3

CGL-50

CGL-225

CGL-4

CGL-60

CGL-250

CGL-6

CGL-70

CGL-300

CGL-10

CGL-80

CGL-350

CGL-15

CGL-90

CGL-400

CGL-20

CGL-100

CGL-450

CGL-25

CGL-110

CGL-500

CGL-30

CGL-125

CGL-600

CGL-35

CGL-150

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

248

IEC & British Standard Fuses

Tron

HRC Form II Class C Fuses

Data Sheet: 4125

2.0"

(50.8mm)

2.80"

(71.04mm)

3.5"

(88.9mm)

0.94"

(23.81mm)

0.06"

(1.59mm)

2.0"

(50.8mm)

2.80"

(71.04mm)

3.31"

(84.14mm)

0.81"

(20.64mm)

0.22"

(5.56mm)

0.22"

(5.56mm)

0.34"

(8.73mm)

CGL 1-30

CGL 35-60

0.50"

(12.7mm)

0.81"

(20.64mm)

0.22"

(5.56mm)

0.22"

(5.56mm)

1.06"

(26.92mm)

0.06"

(1.59mm)

CGL 70-100

0.75"

(19.05mm)

1.34"

(34.04mm)

0.343"

(8.71mm)

0.343"

(8.71mm)

2.39"

(60.72mm)

3.64"

(92.47mm)

4.31"

(109.54mm)

1.375"

(34.93mm)

0.09"

(2.29mm)

CGL 110-200

0.75"

(19.05mm)

0.343

(8.71mm)

0.343"

(8.71mm)

3.00"

(76.2mm)

4.30"

(109.22mm)

5.31"

(134.87mm)

1.50"

(38.1mm)

0.125"

(3.18mm)

CGL 225-400

1.0"

(25.4mm)

0.38"

(9.53mm)

3.0"

(76.2mm)

5.25"

(133.35mm)

8.19"

(207.96mm)

2.38"

(60.33mm)

0.19"

(4.76mm)

1.0"

(25.4mm)

CGL 450-600

0.41"

(10.32mm)

3.00"

(76.2mm)

1.0"

(25.4mm)

1.0"

(25.4mm)

0.375"

(9.53mm)

3.0"

(76.2mm)

5.25"

(133.35mm)

8.19"

(207.96mm)

.60"

(15.24mm)

Dimensions

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

CIF21 HRCI-CA

Specifications
Description:

The HRCI-CA fuse provides

both overload and short-circuit protection to
HRCI requirements. Offset blades for bolt-on
mounting. CIF21 fuse fits the Cooper
Bussmann CAMaster fuse holder (see data
sheet 4132).

Dimensions:

See Dimensions illustration.

Construction:

Ceramic body.

Ratings:

Volts: — 600Vac/250Vdc

Amps: — 1-30A

IR: — 200kA RMS Sym.

Agency Information:

CE, CSA C22.2, No. 106-M92.

Mounting:

Bolt-on.

Catalog Numbers

Catalog

Amp

Numbers

Ratings

1CIF21

1

3CIF21

3

6CIF21

6

10CIF21

10

15CIF21

15

20CIF21

20

25CIF21

25

30CIF21

30

CIF06 HRCI-CB

Specifications
Description:

A miniature industrial fuse that

provides both short-circuit and overload 
protection and the  CIF06 fits the 30A
SAFEloc fuse holder.

Dimensions:

See Dimensions illustration.

Construction:

Ground ceramic body with

plated end caps.

Ratings:

Volts: — 600Vac/250Vdc

Amps: — 1-30A

IR: — 200kA RMS Sym.

Agency Information:

CE, CSA C22.2 No. 106-M92 (3-30A

only).

Mounting:

Clip-in offset blades.

Catalog Number

Catalog

Amp

Numbers

Ratings

1CIF06

1

3CIF06

3

6CIF06

6

10CIF06

10

15CIF06

15

20CIF06

20

25CIF06

25

30CIF06

30

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

249

HRCI Industrial Ceramic Body Fuses

IEC & British

Fuses

Data Sheet: 4128

Data Sheet: 4127

2.15 (54.5)
1.44 (35.5)

1.75 (44.5)

0.19 (4.7)

0.54 (13.8)

0.44 (11.1)

0.03 (0.81)

Features and Benefits

• Close sizing to loads allows using smaller and less costly

switches

• Provides a higher degree of short-circuit protection
• Helps protect motors against burnout from overloads

Typical Applications

• For use in circuits subject to surge currents such as those

caused by motors, transformers and other inductive loads

Dimensions - in (mm)

2.38 (60.4)
1.44 (35.5)

0.54 (13.8)

0.14 (3.5)

0.5 (12.7)

0.03 (3.5)

Features and Benefits

• Close sizing to loads allows using smaller and less costly

switches

• Provides a higher degree of short-circuit protection
• Helps protect motors against burnout from overloads

Typical Applications

• For use in circuits subject to surge currents such as those

caused by motors, transformers and other inductive loads

Dimensions - in (mm)

IEC & British Standard Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

CJ HRCI-J

Specifications
Description:

HRCI-J fast-acting

fuses are industrial duty fuses with 
the excellent current-limiting 
characteristics of fast-acting HRCI-J
fuses to limit damage to equipment
and installations by the thermal and
magnetic energy associated with a
large short-circuit fault current.
Overload characteristics limit cable
damage due to low overload currents.

Dimensions:

See Catalog Numbers table and Dimensions

illustrations.

Construction:

Ceramic body fuse.

Ratings:

Volts: — 600Vac (or less), 250Vdc

Amps: — 1-600A

IR: — 200kA

Agency Information:

CSA C22.2 No. 106 M92; Designed

to BS 88:2, IEC 60269-2.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

250

IEC & British Standard Fuses

HRCI-J Fast-acting Fuses

Data Sheet: 4129

Catalog Numbers

Catalog

Amp

Dimensions - in (mm)

Numbers

Ratings

A

B

C

D

E

F

G

H

J

K

1CJ

1

3CJ

3

6CJ

6

10CJ

10

15CJ

15

2.25 (57)

0.5 (12.7)

0.81 (20.6)

20CJ

20

25CJ

25

30CJ

30

35CJ

35

40CJ

40

45CJ

45

2.38 (60)

0.63 (16)

1.06 (27)

50CJ

50

60CJ

60

70CJ

70

80CJ

80

4.63 (117)

3.63 (92)

1.13 (28)

0.75 (19)

0.13 (3.2)

1 (25.4)

0.5 (12.7)

0.28 (7.1)

0.38 (9.5)

2.63 (67)

90CJ

90

100CJ

100

110CJ

110

125CJ

125

150CJ

150

5.75 (146)

4.38 (111)

1.63 (41)

1.13 (28.6)

0.19 (4.8)

1.38 (35)

0.69 (17.5)

0.28 (7.1)

0.38 (9.5)

3 (76)

175CJ

175

200CJ

200

225CJ

225

250CJ

250

300CJ

300

7.13 (181)

5.25 (133)

2.13 (54)

1.63 (41)

0.25 (6.3)

1.88 (47.6)

0.94 (24)

0.41 (10.3)

0.53 (13.5)

3.38 (86)

350CJ

350

400CJ

400

450CJ

450

500CJ

500

8 (203)

6 (152)

2.63 (66)

2 (51)

0.38 (9.5)

2.13 (54)

1 (25.4)

0.53 (13.5)

0.69 (17.5)

3.75 (96)

600CJ

600

A

J

F

K

B

H

D

C

E

G

A

B

B

C

Dimensions

1CJ to 60CJ

70CJ to 600CJ

Catalog Numbers

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

251

HRCI - Miscellaneous Type K Fuses

IEC & British

Fuses

Dimensions

Data Sheet: 4130

CIH, CIK & CIL HRCI-MISC

Specifications
Description:

HRI fuses provide both overload

and short-circuit protection, featuring offset
blades for bolt down mounting.

Dimensions:

See Catalog Numbers table and

Dimensions illustration.

Construction:

Ceramic body.

Ratings:

Volts: — 600V

Amps: — 1-100A

IR: — 200kA@600V

Agency Information:

CE, CSA C22.2 No.

106 M92.

E

G

G

H

D

K

F
A

L

C

J

B

(The CIL14 has a rejection hole, not a slot as shown above.)

Fuse

Fuse Holder

1-30A

CM30CF

35-60A

CM60CF

Catalog Numbers

Catalog

Amp

Dimensions - in (mm)

Numbers Ratings

A Max

B Max

C Max

D Nom

E Nom

F Nom

G Nom

H Nom

J Max

K Nom

L Max

1CIH07

1

2.25 (57)

0.94 (24)

3.38 (86)

0.38 (9.2)

0.04 (1.0)

2.88 (73)

0.21 (5.2)

0.31 (8)

1 (25.4)

0.10 (2.6)

2.38 (60)

3CIH07

3

6CIH07

6

10CIH07

10

15CIH07

15

20CIH07

20

25CIH07

25

30CIH07

30

35CIK07

35

2.28 (58)

1.06 (27)

3.56 (91)

0.5 (12.7)

0.05 (1.2)

2.88 (73)

0.21 (5.2)

0.41 (10.5)

1.09 (28)

0.13 (3.2)

2.38 (61)

40CIK07

40

50CIK07

50

60CIK07

60

80CIL14

80

2.75 (70)

1.44 (37)

4.38 (111)

0.75 (19)

0.09 (2.5)

3.69 (94)

0.34 (8.7)

0.41 (10.5)

1.5 (38.5)

2.91 (74)

90CIL14

90

100CIL14

100

2.25 (57)

0.94 (24)

3.38 (86)

0.38 (9.2)

0.04 (1.0)

2.88 (73)

0.21 (5.2)

0.31 (8)

1 (25.4)

0.10 (2.6)

2.38 (60)

2.38 (61)

2.91 (74)

0.13 (3.2)

1.09 (28)

1.5 (38.5)

0.41 (10.5)

0.41 (10.5)

0.21 (5.2)

0.34 (8.7)

2.88 (73)

3.69 (94)

0.05 (1.2)

0.09 (2.5)

0.5 (12.7)

0.75 (19)

3.56 (91)

4.38 (111)

1.06 (27)

1.44 (37)

2.28 (58)

2.75 (70)

Recommended Fuse Holders

IEC & British Standard Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

HRC Form II

Specifications
Description:

HRC Form II 

current-limiting fuses.

Dimensions:

See Catalog

Numbers table and Dimensions
illustrations.

Construction:

Ceramic body.

Ratings:

Volts: — 600Vac (or less)

— 250Vdc

Amps: — 2-600A

IR: — 200kA RMS Sym.

Agency Information:

CE, CSA C22.2 No.106M1992; 

BS 88:2, IEC 60269:2.

Typical Applications

• Used to protect motor control circuits, together with 

contactors and overload protection relays to provide Type 2
coordination - per IEC 60947-4.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

252

IEC & British Standard Fuses

HRC Form II Current-limiting Fuses

Data Sheet: 4131

Catalog Numbers

Catalog

Amp

Dimensions - in (mm)

Numbers

Ratings

A

B

C

D

E

F

G

H

J

K

CSA Category

2H07C

2

1.38 (35)

0.56 (14)

3.38 (85)

0.38 (9)

0.06 (1.2)

2.88 (73)

0.22 (5.6)

0.31 (8)

0.56 (14) —

HRCII-C

4H07C

4

6H07C

6

10H07C

10

15H07C

15

20H07C

20

25H07C

25

30H07C

30

40K07C

40

2.19 (56)

0.88 (22)

3.44 (87)

0.5 (13)

0.06 (1.2)

2.88 (73)

0.22 (5.6)

0.31 (8)

0.88 (22) —

HRCII-C

50K07C

50

60K07C

60

80K07CR

80

2.19 (56)

0.88 (22)

3.75 (95)

0.5 (13)

0.06 (1.2)

2.88 (73)

0.22 (5.6)

0.31 (8)

0.88 (22) —

HRCII-MISC

100K07CR

100

80L14C

80

2.38 (60)

0.88 (21.4)

4.38 (111)

0.56 (14.3)

0.13 (3.2)

3.69 (94)

0.34 (8.7)

0.44 (11)

1 (25.4)

HRCII-C

100L14C

100

125M14C

125

2.56 (65)

1.5 (38)

4.38 (111)

0.75 (19)

0.09 (2.4)

3.69 (94)

0.34 (8.7)

0.44 (11)

HRCII-MISC

150M14C

150

200M14C

200

80L09C

80

2.38 (60)

0.88 (21.4)

5 (127)

0.56 (14)

0.13 (3.2)

4.38 (111)

0.34 (8.7)

0.44 (11)

HRCII-MISC

100L09C

100

125M09C

125

2.56 (65)

1.5 (38)

5.38 (136)

0.75 (19)

0.13 (3.2)

4.38 (111)

0.34 (8.7)

0.56 (14)

HRCII-C

150M09C

150

200M09C

200

250P09C

250

3.06 (178)

2.31 (59)

5.38 (136)

1 (25.4)

0.19 (4.8)

4.38 (111)

0.34 (8.7)

0.5 (13)

HRCII-MISC

300P09C

300

350P09C

350

400P09C

400

250P11C

250

3.06 (178)

2.31 (59)

8.25 (210)

1 (25.4)

0.19 (5)

5.25 (133)

0.41 (10)

0.63 (16)

1 (25)

HRCII-C

300P11C

300

350P11C

350

400P11C

400

450R11C

450

3.19 (81)

2.88 (73)

8.25 (210)

1 (25.4)

0.25 (6.3)

5.25 (133)

0.41 (10)

0.63 (16)

1 (25)

HRCII-C

500R11C

500

600R11C

600

E

D

G

F

A

H

C

J

B

E

D

G

F

A

H

C

J

B

D

G

C

A

F

B

E

H

F

B

E

G

C

A

K

D

K

H

H07C
(Offset Blades)

K07C/K07CR/
L14C/M14C 
(Offset Blades)

L09C/M09C/P09C
(Center Blades)

P11C/R11C 
(Center Blades)

Dimensions

1.38 (35)

0.56 (14)

3.38 (85)

0.38 (9)

0.06 (1.2)

2.88 (73)

0.22 (5.6)

0.31 (8)

0.56 (14)

HRCII-C

HRCII-MISC

HRCII-C

HRCII-C

HRCII-C

HRCII-MISC

HRCII-MISC

1 (25)

1 (25)

0.88 (22)

1 (25.4)

0.44 (11)

0.56 (14)

0.5 (13)

0.63 (16)

0.34 (8.7)

0.41 (10)

3.69 (94)

4.38 (111)

5.25 (133)

0.13 (3.2)

0.09 (2.4)

0.13 (3.2)

0.19 (4.8)

0.19 (5)

0.25 (6.3)

0.5 (13)

0.56 (14.3)

0.75 (19)

0.56 (14)

0.75 (19)

1 (25.4)

3.44 (87)

3.75 (95)

4.38 (111)

5 (127)

5.38 (136)

8.25 (210)

2.19 (56)

0.88 (22)

2.38 (60)

0.88 (21.4)

1.5 (38)

1.5 (38)

2.31 (59)

2.88 (73)

2.38 (60)

0.88 (21.4)

2.56 (65)

2.56 (65)

3.19 (81)

3.06 (178)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

SSD, NSD, ESD BS 88 Part 1

Specifications
Description:

The NSD and ESD are low voltage

fuses complying with general purpose gG 
characteristics.

Construction:

Ceramic body.

Ratings:

Volts: — 240-550Vac (See Catalog Numbers table)

Amps: — 2-63A (See Catalog Numbers table)

— 20M25-63M100A Motor Starter ratings 

(See Catalog Numbers table)

IR: — 33kA (SSD) 

— 80kA (NSD, ESD)

Agency Information:

CE, Meets the requirements of 

BS 88 Part 1 and IEC 60269-1.

Mounting:

Offset blades.

Basic Catalog Numbers

Basic

Max AC

Catalog

Amp

Voltage

BS 88

Numbers Ratings

Ratings

Ref.

SSD

2, 4, 6, 10, 16, 20, 25, 32

240

E1

NSD

2, 4, 6, 10, 16, 20, 25, 32, 

550

F1

20M25*, 20M32*, 20M36*, 32M36*, 32M40*,

415

F1

32M50*, 32M63*

415

F1

ESD

2, 4, 6, 10, 16, 25, 32

550

F2

40, 50, 63, 63M80, 63M100*

415

F2

*“M” indicates motor starter ratings.

To Order

To order, specify Basic Catalog Number and amp rating. Example: SSD-20

Recommended Fuse Holders

Basic Fuse

Holder Catalog

Catalog Numbers

Numbers

NSD

32NNSF

ESD

63ENSF

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

253

BS 88 British Standard Low Voltage Fuses

IEC & British

Fuses

STD, NITD, AAO, BAO, OSD, CEO, DEO 
BS 88 Part 1

Specifications
Description:

The STD to DEO types are low

voltage fuses complying with general purpose gG
characteristics.

Construction:

Ceramic body.

Ratings:

Volts: — 240-550Vac (See Catalog Numbers

table)

Amps: — 2-200A (See Catalog Numbers table)

— 20M25-200M315A Motor Starter ratings 

(See Catalog Numbers table)

IR: — 33kA (STD) 

— 80kA (NITD, AAO, BAO, CEO, DEO)

Agency Information:

CE, Meets the requirements of 

BS 88 Part 1 and IEC 60269-1.

Mounting:

Offset bolted blades.

Typical Applications

• The STD type are used in 240V street lighting cut-outs
• NITD to DEO types used for industrial and general purpose

applications

Basic Catalog Numbers

Basic

Max AC

Catalog

Amp

Voltage BS 88

Numbers Ratings

Ratings

Ref.

STD

2, 4, 6, 10, 16, 20, 25, 32

240

NITD

2, 4, 6, 10, 16, 20, 25, 32

550

20M25*, 20M32*, 32M40*, 32M50*, 32M63*

415

AAO

2, 4, 6, 10, 16, 20, 25, 32, 32M40*, 32M50*, 32M63*

550

BAO

40, 50, 63, 63M80*, 63M100*

550

A3

CEO

32, 40, 50, 63, 80, 100

550

A4

100M125*, 100M160*, 100M200*

415

A4

DEO

125, 160, 200, 200M250*, 200M315*

415

OSD

80, 100

550

100M125*, 100M160*

415

*“M” indicates motor starter ratings.

To Order

To order, specify Basic Catalog Number and amp rating. Example: BAO-16

Recommended Fuse Blocks & Holders

Basic Fuse

Block/Holder

Catalog Numbers

Catalog Numbers

NITD

CM32FC

AAO

CM32F

BAO

CM63F

OSD

CM100F

CEO

BH-0111

Data Sheets 4105 (SSD), 4100 (NSD) and 4101 (ESD)

Data Sheets 4123 (STD), 4106 (NITD), 4109 (AAO), 4112
(BAO), 4107 (OSD), 4115 (CEO) and 4117 (DEO)

IEC & British Standard Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

EF, FF, FG, GF, GG, GH
BS 88

Specifications
Description:

Low voltage fuses

complying with general purpose gG
characteristics and available up to
400A with two hole mount and up
to 1250A with four hole mount.

Construction:

Ceramic body.

Ratings:

Volts: — 415/550Vac, 250/400Vdc

(See Catalog Numbers table for details)

Amps: — 355-1250

IR: — See Catalog Numbers table

Agency Information:

CE, Meets the requirements of 

BS 88 Parts 1 and 2 and IEC269-1.

Mounting:

Center bolted blades, four-hole mount.

Basic

Interrupting

Max Voltage

Catalog

Amp

Ratings

Ratings

BS 88

Numbers

Ratings

AC

DC

AC

DC

Ref.

EF

355, 400

80kA

415

C1

400M500*

80kA

550

FF

450, 500, 560, 630

80kA

40kA

550

400

C2

FG

450, 500, 560, 630

80kA

40kA

550

400

GF

710, 800

80kA

40kA

550

250

C3

GG

710, 800

80kA

40kA

550

250

1000, 1250

80kA

550

GH

710, 800, 1000, 1250

80kA

550

*

“M” indicates motor starter ratings.

*

“M” indicates motor starter ratings.

To Order

To order, specify Basic Catalog Number and amp rating. Example: FG-450

AC, AD, BC, BD, CD, DD, ED, EFS BS 88

Specifications
Description:

Low voltage fuses that

comply with general purpose gG 
characteristics and available up to 400A
with two hole mount and up to 1250A
with four hole mount.

Construction:

Ceramic body.

Ratings:

Volts: — 415/550Vac, 250Vdc (See

Catalog Numbers table)

Amps: — 2-400A (See Catalog Numbers table)

— 63M80-400M500A Motor Starter ratings (See

Catalog Numbers table)

IR: — See Catalog Numbers table

Agency Information:

CE, Meets the requirements of 

BS 88 Parts 1 and 2 and IEC 60269-1.

Mounting:

Center bolted blades, two-hole mount.

Basic Catalog Numbers

Basic

Interrupting

Max Voltage

Catalog

Amp

Ratings

Ratings

BS 88

Numbers

Ratings

AC

DC

AC

DC

Ref.

AC

2, 4, 6, 10, 16, 20, 25, 32

80kA

40kA

550

250

AD

2, 4, 6, 10, 16, 20, 25, 32

80kA

40kA

550

250

BC

40, 50, 63

80kA

40kA

550

250

63M80*, 63M100*

80kA

550

BD

40, 50, 63

80kA

40kA

550

250

CD

80, 100, 100M125*, 100M160*,

80kA

415

B1

100M200*, 100M200*

DD

125, 160, 200, 

80kA

415

B2

200M250*, 200M315*

ED

250, 315, 355, 400, 315M400*

80kA

415

B3

400M500*

80kA

550

B4

EFS

125, 160, 200, 250, 315

80kA

415

*“M” indicates motor starter ratings.

To Order

To order, specify Basic Catalog Number and amp rating. Example: BC-40

Recommended Fuse Blocks & Holder

Basic Fuse

Block/Holder

Catalog Numbers

Catalog Numbers

AC

BH-0111 Modular fuse block

AD

200DF Fuse holder

BC

BH-0111 Modular fuse block

BD

200DF-L

CD

200DF-L

DD

200DF-L

ED

BH-1131 Modular fuse block

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

254

IEC & British Standard Fuses

BS 88 British Standard Low Voltage Fuses

Data Sheets 4110 (AC), 4111 (AD), 4113 (BC), 4114 (BD),
4116 (CD), 4118 (DD), 4119 (ED) and 4121 (EFS)

Data Sheets 4120 (EF), 4102 (FF), 4122 (FG), 4103 (GF), 4104
(GG) and 4108 (GH)

Basic Catalog Numbers

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

NZ01, NZ02 Type D0

Specifications
Description:

Low voltage Neozed fuses 

suitable for use on 250Vdc systems.

Dimensions:

See Catalog Numbers table and

Dimensions illustration.

Construction:

Ceramic body.

Ratings:

Volts: — 400Vac

Amps: — 2-63A

IR: — 100kA

Agency Information:

CE

Catalog Numbers

Catalog

Amp

Dimension

Color

Numbers

Ratings

“D” (mm)

Code

2NZ01

2

11

Pink

4NZ01

4

11

Brown

6NZ01

6

11

Green

10NZ01

10

11

Red

16NZ01

16

11

Grey

20NZ02

20

15

Blue

25NZ02

25

15

Yellow

35NZ02

35

15

Black

50NZ02

50

15

White

63NZ02

63

15

Copper

Dimensions - mm

D16, D27, D33, D125 Type D

Specifications
Description:

DIN style Type D

low voltage fuses.

Dimensions:

See Catalog

Numbers table and Dimensions
illustrations.

Construction:

Ceramic body.

Ratings:

Volts: — 500Vac

Amps: — 2-100A

IR: — 100kA

Agency Information:

CE, “D” type fuses complying with

DIN 49360 Part 2 and DIN 49515, operating class gL.

Catalog Numbers

Catalog

Amp

Dimension

Color

Figure

Numbers

Ratings

“D” (mm)

Code

Number

2D16

2

6

Pink

4D16

4

6

Brown

6D16

6

6

Green

10D16

10

8

Red

1

16D16

16

10

Grey

20D16

20

12

Blue

25D16

25

14

Yellow

2D27

2

6

Pink

4D27

4

6

Brown

6D27

6

6

Green

10D27

10

8

Red

2

16D27

16

10

Grey

20D27

20

12

Blue

25D27

25

14

Yellow

35D33

35

16

Black

50D33

50

18

White

3

63D33

63

20

Copper

80D125

80

5

Silver

4

100D125

100

7

Red

Additional Fuse links: Quick acting fuselinks in body sized D16, D27, D33 and 
D125 rated 2-100A. Reference number suffixed Q, i.e. 10D27Q. Voltage rating 500V. 
Gauge rings and keys can also be supplied.

Dimensions - mm

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

255

DIN Style Type D and Neozed Low Voltage Fuses

IEC & British

Fuses

Data Sheet: 4124

D

36

Data Sheet: 4124

Figure 1

Figure 2

Figure 3

Figure 4

IEC & British Standard Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

256

IEC & British Standard Fuses

NH HRC Fuses

___NHG___B

Specifications
Class:

gG/gL

Description:

DIN

square bodied, dual
indication industrial
fuses.

Construction:

Steatite

insulator, corrosion-
proof (aluminum) metal
parts with full-contact,
silver-plated copper
blades.

Sizes:

DIN 000 to 4.

Selectivity Ratio:

1:1.6 up to 500Vac.

Dimensions - mm

Fuse

a

2

b

c

1

c

2

D

e

1

e

2

e

3

e

4

f

Size

a

1

(max)

a

3

a

4

(nom)

(± 8)

(nom)

(nom)

(max)

(max)

(max)

(nom)

(max)

000

78.5 ± 1.5

54

45 ± 1.5

49 ± 1.5

15

35

10

2 ± 0.5

41

21

16

6

8

00

78.5 ± 1.5

54

45 ± 1.5

49 ± 1.5

15

35

11

7.0 ± 0.5

48

30

25

6

15

0

125 ± 2.5

68

62 +3/-1.5

68 +1.5/-3

15

35

11

2.5 ± 0.5

48

30

25

6

15

01

135 ± 2.5

75

62 ± 2.5

68 ± 2.5

15

40

11

2.5 ± 0.5

48

30

25

6

15

1

135 ± 2.5

75

62 ± 2.5

68 ± 2.5

20

40

11

2.5 ± 0.5

53

52

25

6

15

02

150 ± 2.5

75

62 ± 2.5

68 ± 2.5

20

48

11

2.5 ± 0.5

53

52

25

6

15

2

150 ± 2.5

75

62 ± 2.5

68 ± 2.5

25

48

11

2.5 ± 0.5

61

60

25

6

15

03

150 ± 3

75

62 ± 2.5

68 ± 2.5

25

60

11

2.5 ± 0.5

61

60

25

6

15

3

150 ± 3

75

62 ± 2.5

68 ± 2.5

32

60

11

3.0 ± 0.5

75

70

25

6

18

4

200

84

80

90

50

85

11

3

120

87

8

30

Ratings:

Volts: — 500Vac/250Vdc

— 690Vac/250Vdc

Amps: — 2-1250A

IR: — 120kA

Frequency: — 50Hz

Operating Frequency: — 45-62Hz

Agency Information:

IEC 60269, VDE0636, DIN 43620

Part 1 to 4, VDE Mark and CE.

Data Sheet 4173

Fuse Blocks

Size

SB00-D

000-00

SB1-D

1*, 1

SB2-D

02, 2, 03, 3

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

257

NH HRC Fuses

IEC & British

Fuses

Rated

gG/gL Dual Indicator

Current

Voltage Conducting

Carton

500Vac / 250Vdc

Size

(Amps)

Metal Gripping Lugs

Quantity

2

2NHG000B

3

4

4NHG000B

3

6

6NHG000B

3

10

10NHG000B

3

16

16NHG000B

3

20

20NHG000B

3

25

25NHG000B

3

000

32

32NHG000B

3

35

35NHG000B

3

40

40NHG000B

3

50

50NHG000B

3

63

63NHG000B

3

80

80NHG000B

3

100

100NHG000B

3

00

125 125NHG00B

3

160

160NHG00B

3

10

10NHG0B

3

16

16NHG0B

3

20

20NHG0B

3

25

25NHG0B

3

32

32NHG0B

3

35

35NHG0B

3

0

40

40NHG0B

3

50

50NHG0B

3

63

63NHG0B

3

80

80NHG0B

3

100

100NHG0B

3

125

125NHG0B

3

160

160NHG0B

3

10

10NHG01B

3

16

16NHG01B

3

20

20NHG01B

3

25

25NHG01B

3

32

32NHG01B

3

35

35NHG01B

3

01

40

40NHG01B

3

50

50NHG01B

3

63

63NHG01B

3

80

80NHG01B

3

100

100NHG01B

3

125

125NHG01B

3

160

160NHG01B

3

200

200NHG1B

3

1

224

224NHG1B

3

250

250NHG1B

3

35

35NHG02B

3

40

40NHG02B

3

50

50NHG02B

3

63

63NHG02B

3

80

80NHG02B

3

02

100

100NHG02B

3

125

125NHG02B

3

160

160NHG02B

3

200

200NHG02B

3

224

224NHG02B

3

250

250NHG02B

3

315

315NHG2B

3

2

355

355NHG2B

3

400

400NHG2B

3

250

250NHG03B

3

315

315NHG03B

3

03

355

355NHG03B

3

400

400NHG03B

3

3

500

500NHG3B

3

630

630NHG3B

3

500

500NHG4G

1

4

630

630NHG4G

1

Single Indicator

800

800NHG4G

1

Slotted End

1000

1000NHG4G

1

Tags

1250

1250NHG4G

1

IEC & British Standard Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

258

IEC & British Standard Fuses

NH HRC Fuses

Rated

gG/gL Dual Indicator

Current

Voltage Conducting

Carton

690Vac / 250Vdc

Size

(Amps)

Metal Gripping Lugs

Quantity

2

2NHG000B-690

3

4

4NHG000B-690

3

6

6NHG000B-690

3

10

10NHG000B-690

3

000

16

16NHG000B-690

3

20

20NHG000B-690

3

25

25NHG000B-690

3

32

32NHG000B-690

3

35

35NHG000B-690

3

40

40NHG000B-690

3

50

50NHG00B-690

3

00

63

63NHG00B-690

3

80

80NHG00B-690

3

100

100NHG00B-690

3

6

6NHG0B-690

3

10

10NHG0B-690

3

16

16NHG0B-690

3

20

20NHG0B-690

3

25

25NHG0B-690

3

0

32

32NHG0B-690

3

35

35NHG0B-690

3

40

40NHG0B-690

3

50

50NHG0B-690

3

63

63NHG0B-690

3

80

80NHG0B-690

3

100

100NHG0B-690

3

50

50NHG1B-690

3

63

63NHG1B-690

3

80

80NHG1B-690

3

1

100

100NHG1B-690

3

125

125NHG1B-690

3

160

160NHG1B-690

3

200

200NHG1B-690

3

63

63NHG2B-690

3

80

80NHG2B-690

3

100

100NHG2B-690

3

125

125NHG2B-690

3

2

160

160NHG2B-690

3

200

200NHG2B-690

3

224

224NHG2B-690

3

250

250NHG2B-690

3

315

315NHG2B-690

3

250

250NHG3B-690

3

315

315NHG3B-690

3

3

355

355NHG3B-690

3

400

400NHG3B-690

3

425

425NHG3B-690

3

500

500NHG3B-690

3

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

259

IEC & British

Fuses

NH Fuse Bases

SB*-D, SB*-S 
Up to 690V / 160 - 1250A
Sizes 00, 0, 1, 2, 3, 4

Description: 

NH fuse bases with thermoplastic 

bodies. DIN-Rail and screw mounting (siz   e 4 screw 
fix). Range of protection accesories for live parts in
order to obtain IP20 protection standard. 

Ratings:

Volts: up to 690Vac

Amps: 2 to 1250A

Applications:

Protection of industrial circuits and

electrical apparatus

Standards and Approvals:

I

EC 60269, DIN 43620

Part Numbers

Size

Poles

Current

(Amps)

Part Numbers

Carton

Quantity

Compatible

Fuse Size

DIN Screw

00

1

3

160A

SB00-D
TB00-D

TB00-D-IP20

3

1

000 & 00

0

1

3

160A

SB0-D

TB0-D

3

1

0

1

1

3

250A

SB1-D

TB1-D

3

1

01 & 1

2

1

3

400A

SB2-D

TB2-D

3

1

02 & 2

3

1

3

630A

SB3-D

TB3-D

3

1

03 & 3

4

1

1250A

SB4-S (

Screw

Connection only)

3

4

Neutral

Size

Current

(Amps)

Part Ref

Carton

Quantity

NH00

160

SL00

3

NH0

160

SL0

NH1

250

SL1

NH2

400

SL2

NH3

630

SL3

NH4

1000

SL4

Size

Part Ref

Carton

Quantity

C00-3

FEH

1

Fuse extraction handle

Protection accessories

Size

Current

(Amps)

Separation Partition

4

Fuse Casing

5

Terminal Cover

1

Separator

3

Part

Ref

Carton 

Quantity

Part

Ref

Carton

Quantity

Part

Ref

Carton

Quantity

Part

Ref 

Carton

Quantity

NH00*

NH0
NH1
NH2
NH3

160A
160A
250A
400A
630A

SP00*

SP0

SP1-2
SP1-2

SP3

2
2
2
2
2

FC00*

FC0

FC1-2
FC1-2

FC3

3
3
3
3
3

CS00*

CS0
CS1
CS2
CS3

6
6
6
6
6

BC00*

BC0

BC1-2
BC1-2

BC3

2
2
2
2
2

IP Protection Kits

Part Reference

Description

TB00-D-IP20

Complete triple pole fuse base IP20 rated

FPK0-3P

IP20 kit for TB0-D fuse base

FPK1-3P

IP20 kit for TB1-D fuse base

FPK2-3P

IP20 kit for TB2-D fuse base

FPK3-3P

IP20 kit for TB3-D fuse base

Part Ref

Carton Quantity

BVL-50

1

Microswitch

Microswitch suitable for the following NH Fuse links:
- 400 Volts gG/gL
- 500 Volts gG/gL and aM
- 690 Volts gG/gL and aM

* For single pole only

IEC & British Standard Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

260

IEC & British Standard Fuses

Class gG/gL IEC 60269 Industrial Ferrule Fuses

8 x 31mm

: 400Vac, 0.5 - 25A

10 x 38mm

: 500Vac, 0.5 - 32A

14 x 51mm

: 400Vac - 500Vac - 690Vac, 1 - 50A

22 x 58mm

: 400Vac - 500Vac - 690Vac, 2 - 125A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

261

IEC & British

Fuses

Class aM IEC Industrial Ferrule Fuses - Class aM IEC
60269

8 x 31mm

: 400Vac, 1 - 8A

10 x 38mm

: 400Vac - 550Vac, 0.16 - 25A

14 x 51mm

: 690Vac - 500Vac, 0.25 - 50A

22 x 58mm

: 400Vac - 500Vac - 690Vac, 2 - 125A

Neutral Links

IEC & British Standard Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For detailed information, visit the Electrical IEC section at www.cooperbussmann.com

262

IEC & British Standard Fuses

Class aM & gG/gL IEC Industrial Ferrule Fuses with
Striker

Class gG/gL with Striker

Catalog Number

Amp

Watts Loss

Voltage

Interrupting

With Striker

Rating

(W)

(AC)

Rating (kA)

C14G2S

2

0.24

500

120

C14G4S

4

0.45

C14G6S

6

0.42

C14G8S

8

0.70

C14G10S

10

0.53

C14G12S

12

0.88

C14G16S

16

1.16

C14G20S

20

1.23

C14G25S

25

1.46

C14G32S

32

2.04

C14G40S

40

3.34

C14G50S

50

3.04

400

Catalog Number

Amp

Watts Loss

Voltage

Interrupting

With Striker

Rating

(W)

(AC)

Rating (kA)

C22G4S

4

0.48

690

80

C22G6S

6

0.47

C22G8S

8

0.73

C22G10S

10

0.74

C22G12S

12

0.83

C22G16S

16

1.21

C22G20S

20

1.29

C22G25S

25

1.53

C22G32S

32

2.13

C22G40S

40

3.40

C22G50S

50

3.48

C22G63S

63

4.46

C22G80S

80

5.86

500

120

C22G100S

100

6.61

C22G125S

125

8.42

400

Class aM with Striker

Catalog Number

Amp

Watts Loss

Voltage

Interrupting

With Striker

Rating

(W)

(AC)

Rating (kA)

C14M1S

1

0.14

500

120

C14M2S

2

0.24

C14M4S

4

0.45

C14M6S

6

0.42

C14M8S

8

0.70

C14M10S

10

0.53

C14M12S

12

0.88

C14M16S

16

1.16

C14M20S

20

1.23

C14M25S

25

1.46

C14M32S

32

2.04

C14M40S

40

3.34

C14M50S

50

3.04

400

Catalog Number

Amp

Watts Loss

Voltage

Interrupting

With Striker

Rating

(W)

(AC)

Rating (kA)

C22M2S

2

0.29

690

80

C22M4S

4

0.48

C22M6S

6

0.47

C22M8S

8

0.73

C22M10S

10

0.74

C22M12S

12

0.83

C22M16S

16

1.21

C22M20S

20

1.29

C22M25S

25

1.53

C22M32S

32

2.13

C22M40S

40

3.40

C22M50S

50

3.48

C22M63S

63

4.46

C22M80S

80

5.86

500

120

C22M100S

100

6.61

C22M125S

125

8.42

400

14 X 51

22 X 58

14 X 51

22 X 58

500

120

80

120

690

500

500

120

80

120

690

500

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

SAFEloc

Specifications
Catalog
Symbol:

See table below.

Description:

The

SAFEloc HRC
fuse holders (for
use with HRCI-CB
fuses) provides a
positive, stress-
free fuse fitting
and locks it in position to ensure safe insertion and 
withdrawal from the base. Base contacts are fully shrouded
to help protect against electric shock. Shrouds utilize 
simple slide/snap action allowing access to the contact 
terminal screws.

Ratings:

Volts: — 600V

Amps: — 30-60A (See Catalog Number table for details)

Agency Information:

CE, Designed to accommodate the

compact range of offset blade fuse to CSA C22.2 No. 106,
HRCI-CB.

Mounting:

35mm DIN-Rail or single screw mounting.

Catalog Numbers*

Catalog

Amp

Fuse

Numbers

Ratings

Connection

Accepted

C30F

Front

C30BS

30

Back

_CIF06

C30FBS

Front-Back

C60F

Front

C60BS

60

Back

EK-Amp

C60FBS

Front-Back

*For use with HRCI-CB Fuses.

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

263

CAMaster

Specifications
Catalog Symbol:

See table below.

Description:

The

CAMaster HRC fuse holder
features a unique 
cam-action for easy fuse
removal while allowing 
significantly improved 
contact pressure between
fuse carrier and base 
contact that enhances 
electrical performance. A range of lockable safety carriers for
the fuse holder (catalog reference: LSC), are available.

Ratings:

Volts: — 690V

Amps: — 30-100A (See Catalog Number table for details)

Agency Information:

CE, CSA C22.2 No. 39; IEC 269

AND BS 88.

Mounting:

35mm DIN-Rail or single screw mounting.

Catalog Numbers

Catalog

Amp

Fuse

Numbers

Ratings

Details For:

Accepted

CM20CF

30

HRCI-CA Applications

_CIF21

CM30CF

30

_H07C

CM60CF

60

HRCII Applications

_K07C

CM100CF

100

_K07CR

Accessory Catalog Numbers for CAMaster Units

Catalog

Amp

Fuse Holder

Numbers

Ratings

Details

Accepted

20BS

30

CM20CF

32BS

30

Back Stud

CM30CF

60/100BS

60/100

CM60/100CF

GLP

All

Ganging Link Kit

3-Pole

NI

All

660V Neon Indicator

20LSC

30

CM20CF

30LSC

30

Security Carrier with Clip

CM30CF

60/100LSC

60/100A

CM60/100CF

HRC Fuse Holders

Data Sheet: 4132

Data Sheet: 4133

IEC & British Standard Fuses

IEC & British

Fuses

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

264

The new Quik-Spec coordination 
panelboard with a footprint up 
to 40% smaller than other 
fusible panelboards is now 
available up to 1200A

Quik-Spec
coordination 
panelboards

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

265

Quik-Spec™

Electrical

Gear

Quik-Spec

Electrical Gear

Section Contents

Page

Quik-Spec Coordination Panel Boards . . . . . . . . . 266-267

Quik-Spec Power Module Switches and Panels . . 268-269

Quik-Spec DC Safety Switches . . . . . . . . . . . . . . . . . . 270

Quik-Spec AC Safety Switches . . . . . . . . . . . . . . . . . . 271

A/C Disconnects - Fused and Non-Fused . . . . . . . . . . .272

RED 

indicates

NEW 

information

Scan this tag to get the

latest product information for 

Quik-Spec Coordination Panel Boards.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

266

Quik-Spec

Electrical Gear

Specifications
Description:

Configurable fusible panelboard with 30-400A

mains and branches from 1-100A rated 600Vac.

Ratings:

Volts: — 600Vac (or less), 125Vdc (or less)**

Bus Amps: — 30, 60, 100, 200, 225 or 400A

Options:

Main: — MLO (main lug only)

— Fused disconnect switch

— Non-fused disconnect switch

Enclosure: — NEMA 1 or 3R

— Standard size panelboard (20˝ W x 5˝ D x 

various heights)*

— For other ratings consult factory

Panel: — Feed; Top & Bottom***

— Mounting; Surface or Flush**** 
— Door/Trim; Regular or Door-in-Door****   

Branch: — Circuits; Up to 18, 30 and 42*

— Amps; Up to 100A
— Type; 1-, 2- and 3-Pole

Fuse: — Six-fuse spare fuse compartment

— Time-delay or UPS/critical applications 

(fast-acting) CUBEFuse™

Assembly

SCCR:— 200kA, 100kA or 50kA AC,100kA or   

20kA@125Vdc*

Through-Lugs 

& Loadside

Disconnect:— Feed-Through - single and double

— Fused loadside disconnect, ≥100A-≤ 200A  

(400A panels only) 

Neutrals:— 200A and 400A Unbonded and Bonded

Ground:— Non-Isolated or Isolated

*Depending on configuration

**125Vdc rating applicable to 40 amp or less CCPBs on MLO 

panels only.

***Top feed not available on NEMA 3R enclosure

****Flush mount and Door-in-Door not available with NEMA 3R 

enclosure

Agency Information:

UL Listed to UL 67, complies with

NFPA 70 (NEC

®

; National Electric Code),

Features and Benefits:

• UL and CSA listing makes it easy to address NEC

®

selective

coordination requirements in an all fused system

• Value-engineered for greater flexibility with up to 400A mains,

200kA SCCR, 100A branches with 18, 30 and 42 branch
positions

• Same size footprint as traditional circuit breaker panelboards

and 40% smaller than standard fusible panelboards:
20˝ W x 5 

3

4

˝ D x various heights (depending on 

configuration)

• Increase safety with current-limiting finger-safe Low-Peak

CUBEFuse that reduces arc flash hazard levels

• Quik-Quote online configurator makes specifying and

ordering easy – delivers a full bill of material and 
submittal drawings for an entire project

• Available for 10 day shipment with QuikShip™ service

Ordering:

The QSCP is factory configured to the specific electrical 
system. Contact your Bussmann distributor or representative
to place your order. Have all relevant electrical and circuit
information on hand.

QuikShip – 10 Business Day Shipment

30-400A Quik-Spec™ Coordination Panelboard

Data Sheet: 1159

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

267

Quik-Spec™

Electrical

Gear

Quik-Spec

Electrical Gear

600-1200A Quik-Spec™ Coordination Panelboard

Panel

Branch Configurations

Dimension

Ampacity

(inches)

H

W

D

(18) 1-100A
(18) 1-100A + 200A single
(18) 1-100A + 200A twin

600A

200A single + 200A single

65

27 15

200A single + 200A twin
200A twin + 200A twin
(2) 300A single

89

38 15

(18) 1-100A + 200A single
(18) 1-100A + 200A twin

65

38 15

(2) 200A twin

800A

(18) 1-100A + 400A single
200A twin + 400A single

89

38 15

(2) 400A single
(18) 1-100A + 600A single
(3) 200A twin

89

38 15

200A twin + 600A single

1200A

(2) 200A twin + 400A single
(3) 400A single
600A single + 400A single + 200A single

102 38 15

600A single + 400A single + 200A twin
(2) 600A single

Data Sheet: 1171

• 

UL listing makes it simple to address NEC

®

selective 

coordination system requirements in an all fused system

• Quik-Quote online configurator makes specifying and 

ordering easy – delivers a full bill of material and submittal 
drawings for an entire project

Ordering:

The QSCP is factory configured to the specific electrical 
system. Contact your Bussmann distributor or representative
to place your order. Have all relevant electrical and circuit
information on hand.

QuikShip – 10 Business Day Shipment

Specifications
Description:

Fusible panelboard with 600, 800 and 1200A

mains and branches from 1-600A, rated 600Vac.

Ratings:

Volts: — 600Vac (or less), 125Vdc

Amps: — 600, 800 and 1200A

Options:

Main: — Main lug only

Enclosure: — NEMA 1 floor mount

Branch: — 1-, 2- and 3-pole, 15-600A branch disconnect

Fuse: — Time-delay, non-indicating (Class CF TCF_R 

and/or Class J LPJ_SP) 

— Time-delay, indicating (Class CF TCF_ and/or 

Class J LPJ_SPI) 

— Fast-acting, non-indicating (Class CF TCF_RN 

and/or Class J JKS)

— DFJ high speed Class J fuses

Agency Information:

Complies with NFPA 70 (NEC

®

;

National Electrical Code

®

) UL Listed to UL 67,

Features and Benefits:

• Configurable panelboards with options for 600, 800 and 

1200A mains and branches from 1-600A all rated 200kA 
SCCR at 600Vac

• Smallest standard fusible panelboards in the industry
• Featuring the finger-safe UL Class CF CUBEFuse with 

1-600A ampacity rejection features (1-100A) 

• 

Available with time-delay or UPS/Critical application 
fast-acting fuses

Configuration and Dimension Chart

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

268

Quik-Spec™ Power Module — All-in-one Elevator Disconnect

PMP*

Power Module™ Panel (PMP) for multiple elevator applications.

PS*

The Quik-Spec™ Power Module Switch (PS) for single 
elevator applications.

PS & PMP

Bussmann Quik-Spec Power Module

Specifications
Description:

Fusible power switch or panel with shunt trip

and fire safety interface to allow for single point tie in with fire
alarm system.

Ratings:

Volts: — 600Vac, 3Ø

Amps: — 30-400A (PS)

— 30-200A (PMP feeder switches)

— 400-800A (PMP main switches*)

Assembly

SCCR:— 200kA RMS

*Contact Bussmann for applications greater than 800A.

Agency Information:

Complies with NFPA 70 (NEC

®

;

National Electrical Code

®

),

— Power Module Switch (PS); UL Listed (UL 98) Enclosed 

and Dead front switch Guide 96NK3917, File 
E182262, NEMA 1, UL 50 Listed enclosure**, cUL per

Canadian Standards C22.2, No. 0-M91-CAN/CSA 

C22.2,  No. 4-M89 Enclosed switch.

**NEMA 12, 3R, and 4 enclosures also available

— Power Module Panel (PMP); UL 98 Enclosed and 

Deadfront Switches.

Features and Benefits:

• Internally powered, relay activated shunt trip system
• Mechanically interlocked auxiliary contact
• Self-contained adherence to elevator consensus standards,

NFPA 70 (NEC

®

). NFPA 72, ANSI/ASME 17.1  

• 

Shunt trip capability

• 

Selective coordination

• 

Fire safety signal interface

• 

Shunt trip voltage monitoring

• 

Component protection via Bussmann Low-Peak™
Class J fuses

• 

UL 98 Listed for 200kA short-circuit current rating

• 

Lockable in the open position with three-lock capability

• 

Optional key-test switch and optional pilot light for easy
inspection

• 

No annual calibration or testing of  overcurrent protection
required

• 

Padlockable for service-work safety and open-door

“override” for troubleshooting

*Fused main disconnect requires Class J fuses, not supplied with switch.

Typical Applications:

• Elevator Disconnects
• Computer Room Shunt Trip Disconnect
• Fire Safety Interface Relay

Accessories:

• For added safety, use the Bussmann SAMI™ fuse covers to 

improve maintenance personnel protection (OSHA 1910.333,
paragraph C)

Ordering:

The Bussmann Quik-Spec™ Power Module Switch and
Panel are factory configured to the specific application.
Contact your Bussmann representative to place your order.
Have all relevant electrical and circuit information on hand.

• Elevator Shutdown – ANSI/ASME A17.1, 2.8.3.3.2

– NEC

®

620.51(B) (Elevator 

Shutdown)

– NEC

®

240.12 (Orderly 

Shutdown)

• Shunt Trip Voltage Monitoring – NFPA 72, 6.16.4.4
• Selective Coordination – NEC

®

620.62

• Auxiliary Contact (Hydraulic Elevator) – NEC

®

620.91(C)

Quik-Spec

Electrical Gear

Scan this tag to get the

latest videos for the

Power Module.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

269

Quik-Spec™ Power Module — All-in-one Elevator Disconnect

Hydraulic Elevators

Hydraulic elevators need battery backup to help prevent
stranding passengers. To keep the elevator from moving
when it’s been manually shut down for maintenance, the
NEC

®

requires battery backup be connected to the elevator

disconnecting means through an auxillary contact.

However, an unintended consequence can be passengers 
getting stranded because of  devices that open 
automatically (circuit breakers and disconnects utilizing a

molded case switch with a trailing fuse block) will operate
with a fault on their loadside. That operation also disables
the battery backup and strands passengers. That’s why the
Power Module has a non-automatic fusible shunt trip
switch. If  the Power Module has a fault on its loadside, the
fuses open and the battery stays enabled. Thus the Power
Module ensures that battery power is enabled when the
passengers need it to exit - and disabled to allow safe 
maintenance of  the elevator and hoistway.

Battery

Offered By

Offered By

Lowering

Power

Other Elevator

Scenario

Required

Reason

Module™

Disconnects

Power failure

Yes

Need to lower elevator to allow passengers to exit.

Yes

Yes

Fire in shaft or

Recall is initiated by smoke detector and lowers elevator to

machine room

No

a safe floor. Battery not needed.

Yes

Yes

Disconnect manually

Worker to perform maintenance. Elevator must remain

opened

No

stationary to prevent injury.

Yes

Yes

Fault on loadside of

Need to lower elevator to allow passengers to exit.

Yes

No

disconnect

Yes

Ship-direct service within three business days for Power Module Switches 
(PS_) and 10 business days for Power Module Panels (PMP_).

* Three day PS_ shipment requires ordering from catalog numbers shown.
** 10 Day PMP_ shipment covers NEMA 1 enclosures with the ampacities shown and all requirements 

for relay type (AC or DC), accessory options and number of switches. To order PMP_, contact your 
Bussmann representative with all relevant electrical and circuit information, we do the rest.

Power Module Switch*

Power Module Panel**

Cat Numbers

Amps

Volts

Cat. Numbers

Amps

PS6T48R1KGBF3-X

60A

480V

PMP-400-X

400A

PS1T48R1KGBF3-X

100A

480V

PMP-600-X

600A

PS1T20R1KGBF3-X

100A

208V

PMP-800-X

800A

PS2T48R1KGBF3-X

200A

480V

PS2T20R1KGBF3-X

200A

208V

Quik-Spec™ Power Module Switch Catalog Numbering System

Quik-Spec™

Electrical

Gear

Quik-Spec

Electrical Gear

Power Module Switch Catalog Number System

PS = Power Module Switch

Amp Rating

3 = 30A

1 = 100A

4 = 400A

6 = 60A

2 = 200A

Control Transformer*

T20 = 208 Volt

T48 = 480 Volt

T24 = 240 Volt

T60 = 600 Volt

Fire Safety Interface Relay (3PDT, 10A, 12V)

R1 = 120Vac Coil

R2 = 24Vdc Coil

Optional Key Test Switch

K = Key

Optional Pilot Light ON

G = Green

R = Red

W = White

Optional Neutral Lug

††

N6 = 30-60A

N2 = 200A

N1 = 100A

N4 = 400A

Auxiliary Contacts

B = 2 NO/NC

Fire Alarm Voltage Monitoring Relay (To Monitor Shunt Trip Voltage)

F1 = Single-Pole

F3 = Three-Pole**

Optional NEMA Enclosures (Type 1 Standard With No Suffix Designation Required)

U = Type 3R

Z = Type 12

Y = Type 4

PS 1 T48 R1 K

G

N1

B

F1

U

* 100Va with Primary and Secondary fusing (120V Secondary)                 ** Only for use with R1 option

† Required equipment.                                              

†† Neutral lug rating should be equal to or greater than the switch amp rating.

Quik-Ship Program: Switch - 3 Days, Panel -  10 Days!

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

270

Quik-Spec™ DC Safety Switch

DC Safety Switch Catalog Numbering System

Use this build-a-code to specify the exact Quik-Spec DC Safety Switch you need.

BD

1

6

1

F

R

Prefix

BD

= Heavy Duty

DC Safety Switch

Poles

1

= 1-Pole

Voltage

6

= 600Vdc

Amps

1

= 30A

2

= 60A

3

= 100A

4

= 200A

Type

F

= Fusible with

neutral

N

= Non-fusible with

neutral

Enclosure Type

R

= NEMA 3R 

D

= NEMA 12

W

= NEMA 4X

Stainless

High Visibility Padlockable Handle

Easy to operate with gloves and up 
to three padlocks to protect 
maintenance personnel

NEC 690.17 Compliant
Label

Warns that the switch 
terminals may be energized
in the open position

Visible Switch Contacts

Positive visual identification of
switch state

Door Interlock

Prevents opening door while energized, but can be
manually overridden for testing or inspection.

Clear Polycarbonate Deadfront

Covers energized parts to provide added 
protection against electrical hazards. Lineside stays
in place during fuse servicing.

Fused Version For Added Protection

Fuse clips located on switch center pole to ensure
both clips are de-energized in OFF position. Meets
NEC

®

Article 690.16 that requires isolating the fuse

from all potential supply sources. Cooper Bussmann
recommends using the Limitron fast-acting, current
limiting PVS-R Class RK5 fuse (order separately.)

NEMA 3R, 12 & 4X Enclosures

Meet many application 
requirements. 3R and 4X 
stainless steel well suited for
isolating outdoor solar power 
installations

Conduit Knockouts

For easy conductor installation

Typical Wiring Diagram

Fused

Non-Fused

Neutral

Neutral

Line

Line

Load

Load

Dimensions - in

Amps

A

B

C

Main Lug Capacity

Neutral Lug Capacity

I

SC

30

16.35

8.87

9.89

#2 AWG - #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu

19.2

60

16.35

8.87

9.89

#2 AWG- #14 AWG Al/Cu

#4 AWG - #14 AWG Al/Cu

38.4

100

22.15 11.84 9.89

1/0 AWG- #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu

64.0

200

28.27 16.66 11.26

250kcmil - #6 AWG Al/Cu #2 AWG - #14 AWG Al/Cu

128.0

Amps

A

B

C

Main Lug Capacity

Neutral Lug Capacity

I

SC

30 & 60

14.14

8.76

10.22

#2 AWG - #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 19.2

Non-fusible
30 & 60

19.08

8.76

10.22

#2 AWG - #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 19.2

Fusible
100

24.95

11.79 10.22

1/0 AWG- #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 64.0

200

35.38

16.95 11.63

250kcmil - #6 AWG Al/Cu

#2 AWG - #14 AWG Al/Cu 128.0

• Flange Handle Operation

• Current-Limiting Fuses Reduce Arc Flash Hazard

• Flexibility of Application

• Enhanced Finger-Safe Design

• Meets UL and NEC

®

Requirements

Isolating DC Circuits Has Never Been Easier 

or

Safer

Type 3R Dimensions

Type 12 & 4X Dimensions

Quik-Spec

Electrical Gear

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

271

Quik-Spec™

Electrical

Gear

Quik-Spec

Electrical Gear

Quik-Spec™ Safety Switch

Bussmann Quik-Spec™ Safety Switch

Specifications

Description: 

The Bussmann Quik-Spec™ Safety Switch

equipped with finger-safe Low-Peak CUBEFuse provides
superior safety and reliability for industrial customers.

Utilizing the Bussmann Class CF Low-Peak CUBEFuse, the
Quik-Spec Safety Switch provides Class J fuse performance
characteristics that can help mitigate incident energy and
arc-flash hazard, and offers excellent component protection.  

The Bussmann CUBEFuse requires no tools to install or
replace.

Agency Information:

• UL 98 standard for enclosed deadfront switches. 
• UL 50 standard for enclosures for electrical equipment. 
• NEMA KS 1. 
• UL Listed, File E5239. 
• cUL Listed to C22.2 No.4-M89. 

Optional Features:

• Viewing window for visible blades and open fuse indication 
• NEMA 1, 3R, 12, 4X (stainless)
• Suitable for use as service equipment (with neutral kit) 

Dimensions - inches (mm)*

NEMA 1 & 3R

*See Data Sheet 1156 for 4X and 12 

dimension information and maximum  
horsepower ratings.

Standard Features:

• Extended line terminal shield and finger-safe 30, 60, or

100A Bussmann CUBEFuse

• 200kA short-circuit current rating
• Visible double break quick-make, quick-break rotary blade

mechanism

• Triple padlocking capability
• Mechanically interlocked door
• 600Vac/250Vdc maximum

Quik-Spec

Safety Switch Catalog Numbering System

Switch Type

Series

Window (Optional)

CF

=Heavy Duty

CUBEFuse

Safety Switch

6

=600Vac

W

= Window

K

= Switch

Amp

1

= 30A

2

= 60A

3

= 100A

Fusible

Voltage

Poles

3

= 3-Pole

F

= Fusible

N

=Fusible with

Neutral*

Enclosure Type

G

= NEMA  1

R

= NEMA 3R

D

= NEMA 12

W

= NEMA 4X Stainless

CF

3

6

1

F

G

K

W

*Suitable for service entrance use 

with neutral kit installed.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

272

Quik-Spec

Electrical Gear

A/C Disconnects — Fused and Non-fused

Data Sheet: 1143

Metallic Fused Disconnect

Metallic Non-Fused Disconnect

Catalog Numbers

Fused

Disconnect

Max Hp Rating

Wire Range

Enclosure

Fuse

Approx. Dimensions (in)

Catalog Numbers Description

Rating

120V

240V

60 or 75°C Cu/Al

Type

Class

Height Width Depth

B221-30F

30A, Pullout

30A

1.5

3

#14-3

NEMA 3R

H or R

3

4

3

8

7

8

B221-30FGF

30A, Pullout w/ GFCI

30A

1.5

3

#14-3

NEMA 3R

H or R

13

1

2

3

4

B221-30FGFWRTR

30A, Pullout w/ WRTR-

30A

1.5

3

#14-3

NEMA 3R

H or R

13

1

2

3

4

Rated GFCI

B222-60F

60A, Pullout

60A

3

10

#14-3

NEMA 3R

H or R

3

4

3

8

7

8

B222-60FGF

60A, Pullout w/ GFCI

60A

3

10

#14-3

NEMA 3R

H or R

13

1

2

3

4

B222-60FGFWRTR

60A, Pullout w/ WRTR-

60A

3

10

#14-3

NEMA 3R

H or R

13

1

2

3

4

Rated GFCI

Non-Fused

B222-60NF

60A, Pullout

60A

3

10

#14-3

NEMA 3R

*

3

4

3

8

7

8

B222-60NFGF

60A, Pullout w/ GFCI

60A

3

10

#14-3

NEMA 3R

*

11 

3

4

1

2

1

2

B222-60NFGFWRTR

60A, Pullout w/ WRTR-

60A

3

10

#14-3

NEMA 3R

*

11 

3

4

1

2

1

2

Rated GFCI

B222-60NFNA

60A, Switch

60A

*

10

#14-3

NEMA 3R

*

3

4

3

8

5

8

30 and 60A pullout replacement handle: 96-3258-4.
*Upstream overcurrent protective device (OPCD) not to exceed 60A.

Metallic Non-Fused
Disconnect with
Weather Resistant-
Tamper Resistant
GFCI Receptacle.

Series B22__

Specifications
Description:

Fused and non-fused rainproof pullout air 

conditioner units.

Dimensions:

See Catalog Numbers table.

Construction:

NEMA 3R metal housing with weather resistant

coating.

Wire Range:

14-3 AWG, Al/Cu

Ratings:

Phase: — Single, 2-wire

Volts: — 240Vac

Amps: — 30-60A

Agency Information:

UL Listed to UL 1429, cUL Certified, 

UL Guide WGEW

Features and Benefits

• A/C disconnects meet NEC

®

Code Requirements under 

articles 440.14. GFCI units meet NEC

®

Code Requirements

under articles 210.63, 210.8, and 406.8(B)(1).

• NEMA 3R rainproof enclosures withstand outdoor environment.
• Padlockable with two-position pullout handle to lock safety

shield when in the ON position. (Not available on GF or NA
units.) For added safety, pullout handle can be stored in the
compartment in the off position.

Typical Applications

• Residential, light industrial/commercial A/C and heat pump service.
• Spas/whirlpools, swimming pools, pump houses.
• Suitable for service entrance equipment applications with field

installable ground bar, kit number DPFG.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

273

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Section Contents                          Page

CH Series Global Modular fuse holders 

and accessories . . . . . . . . . . . . . . . . . . . . . 274-280

Remote Fuse Monitoring - CH-PLCCH . . . . . . . . . . . . 278 
Comb-Bus bar specifications and selection guide  . . . . 279 
Comb-Bus bar features and installation guide  . . . . . . 280

CH Series Class J modular fuse holders . . . . . . . . . . . . 281
OPM-1038 3-pole fuse holders with

disconnect switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282

OPM-1038 3-pole fuse holders . . . . . . . . . . . . . . . . . . . 283
OPMNGA- 3-pole Class CC and 

13

32

˝ X 1 

1

2

˝ 

fuse overcurrent protection modules . . . . . . . . . . .284-285

JT(N)60030 & JT(N)600600 Safety J™ Class J 

fuse holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286-287

SAMI™ fuse covers . . . . . . . . . . . . . . . . . . . . . . . . . . . 288

Modular Knifeblade Fuse Holders

289-290

Class R, H(K), 250 & 600V . . . . . . . . . . . . . . . . . 291-292
Class J, 600V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293

H250 & R250 Series 250V Class H (K) and 

R fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . .294-295

H600 & R600 600V Class H (K) and 

R fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . .296-297

J600 Series Class J fuse blocks  . . . . . . . . . . . . . .  . . . 298
JP Series Class J fuse blocks . . . . . . . . . . . . . . . . . . . . 299
T300 300V Class T fuse blocks . . . . . . . . . . . . . . . 300-301
T600 600V Class T fuse blocks . . . . . . . . . . . . . . . 302-303
BCA Series Class CC add-a-pole modular 

fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304

BMA Series 

13

32

˝ X 1 

1

2

˝ fuse add-a-pole modular 

fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304

BC Series Class CC fuse blocks . . . . . . . . . . . . . . . . . .305
BM Series Type M 

13

32

˝ X 1 

1

2

˝ fuse blocks . . . . . . . . . . . 305

BG & G Series Class G fuse blocks  . . . . . . . . . . . . . . . 305
BH Series high speed fuse modular fuse blocks  . . . . . 306
Class H & J modular fuse blocks . . . . . . . . . . . . . . . . . .306
Plug fuse box cover units  . . . . . . . . . . . . . . . . . . . . . . .307
HFB & HEB-10 in-line fuse holders 

for 

1

4

˝ X 1 

1

4

˝ fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . .308

HHB & HRK universal in-line fuse holders for 

1

4

˝ dia. fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308

HR & HM Series in-line fuse holders for 

1

4

˝ dia. fuses . . 309

HFA Series waterproof in-line fuse holders  

for 

1

4

˝ X 1 

1

4

˝ fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . .309

HHT Series in-line fuse holders for 

5 X 15 to 20mm fuses . . . . . . . . . . . . . . . . . . . . . . . . .309

Tron

in-line fuse holders 

(New HEZ)

. . . . . . . . . . . . 309-311

Panel mounted fuse holders for 5 X 20mm fuses . . . . . . .312
Panel mounted fuse holders for 

1

4

˝ X 1 

1

4

˝ fuses . . . . . . . . 313

Panel mounted fuse holders for 5 X 20mm and 

1

4

˝ X 1 

1

4

˝ fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314-315

Panel mounted fuse holders for indicating type fuses  . .  316
Panel mounted fuse holders for 

13

32

˝ X 1 

5

16

˝ to 1 

1

2

˝ fuses . . . . . . . . . . . . . . . . . . . . . . . . .317

Panel mounted fuse holders for 

13

32

˝ X 1 

1

2

˝ fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318

Fuse blocks for 

1

4

˝ X 1 

1

4

˝ fuses . . . . . . . . . . . . . . . . . . . . 319

Fuse blocks for 

1

4

˝ X 1˝ fuses . . . . . . . . . . . . . . . . . . . . . . 320

Fuse blocks for 

13

32

˝ X 1 

1

2

˝ fuses . . . . . . . . . . . . . . . . . . . .321

Rail mount fuse holders . . . . . . . . . . . . . . . . . . . . . . . . . . 322

RED 

indicates

NEW 

information

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

274

Fuse Holders and Blocks

Global Modular Fuse Holders

CH Series - 8x32, 10x38, 14x51, 22x58,
Class CC

Specifications
Description:

The ‘CH’ line of modular fuse holders 

accommodates many fuses from around the world, including
North American Class-CC, Midget, Class gR, aR HSF, and
IEC Industrial Ferrule (Class gG and aM) in four physical
sizes: 8x32, 10x38, 14x51 and 22x58mm.

With 

Indicator

Without 

Indicator

CHM1DIU 

CHM1DU    

1

CHM2DIU  

CHM2DU  

2

CHM3DIU 

CHM3DU    

3

CHM4DIU  

CHM4DU     

4

CHM1DNIU  

CHM1DNU 

1 pole + 1 

neutral

CHM3DNIU

CHM3DNU    

3 poles + 

1 neutral

CHM1DI-48U

UL 48Vdc/30A; 

IEC 

48Vdc/32A

1

CHM1DNXU   

IEC 690V/32A

IEC60269-2

1 neutral

n/a

n/a

CHPV1IU   

CHPV1U    

1

CHPV2IU CHPV2U 

 

 

2

CHCC1DIU   

CHCC1DU    

1

CHCC2DIU   

CHCC2DU  

2

CHCC3DIU 

CHCC3DU    

3

CHCC1DI-48U

UL 48Vdc/30A

1

SCCR 

Rating

Cooper Bussmann 

Fuses

Voltage & 

Current

Catalog Number

Agency 

Markings

Number 

of Poles

Terminal 

Rating

Series & 

Size

CHPV

CHCC 

Class CC

CHM 

10x38 

and 

Midget

UL & IEC; 

1000Vdc/30A

UR, CSA, 

UL4248-18, 

IEC60269-1

Solid, 

Stranded, 

Fine 

Stranded, 

Spade 

Lug, Comb 

Bus Bar; 

Single and 
Dual Wire; 

75ºC and 

90ºC Cu 

wire

33kA rms 

sym

UL 600V/30A

200kA 

rms sym

UL 

600V/30A; 

IEC 

690V/32A

cURus; IEC 

60269-2

LP-CC, FNQ-R,

KTK-R

cULus

100kA 

rms sym

FNQ, KLM, FNM, 

KTK, BAF, FWA, 

DCM, C10 SERIES, 

AGU, BAN, FWC

Solar PV series

60269-2

Agency Information:

UL File E14853

Guide IZLT Listed, IZLT2 Recognized
CSA: File 47235, CHPV and CHM - Class 6225-30, 
CHCC - Class 6225-01

Ratings:

600V/30A (UL)
690V/32A (IEC)

Wire Range:

#18 to #4 (0.8mm

2

to 21.1mm

2

)

Torque Ratings:

30 Lb-In (3.4 N•m) maximum

Flammability Ratings:

UL 94V0, self-extinguishing

Storage & Operating Temperature Range:

-20ºC to +90ºC (indicating) 
-20ºC to +120ºC (non-indicating)

Features/Benefits

•  High SCCR rated, UL Listed Class CC holder with indicator

option for 600Vac/dc and 48Vdc.

•  UL Recognized midget and 10 x 38 holders with factory 

assembled neutral pole option.

•  Agency ratings up to 1000Vdc for use with solar PV fuses.

•  Available remote PLC indication with the CH-PLC module.  

•  Terminals rated for use with 75ºC or 90ºC wire, fine 

stranded wire, spade terminals and comb-bus bars. Use 
any higher temperature rated wire with appropriate 
derating.

•  Complete range of UL Listed and high SCCR rated 

1-phase and 3-phase finger-safe comb-bus bars and 
power feed lugs.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

275

Fuse Holder

s

& Blocks

For additional information see reorder #3185

Fuse Holders and Blocks

CHPV & CHPVI

CHM & CHMI

CHCC & CHCCI

Wire Range

Conductor

No. of

Torque

Type

Conductors

18-14 AWG

20 in-lbs

(0.8-2.0mm

2

)

Single

2.3 Nm

18-16 AWG

25 in-lbs

(0.8-1.3mm

2

)

Solid,

Dual

2.8 Nm

14-10 AWG

Stranded

(2.0-5.2mm

2

)

12-10 AWG

(3.3-5.2mm

2

)

8-4 AWG

Stranded,

30 in-lbs

(8.3-21.1mm

2

)

Fine

3.4 Nm

Stranded

18-14 AWG

Spade

Single

(0.8-2.0mm

2

)

Terminal

N/A

Comb Bus

USE MIDGET / 10X38 FUSE

75ºC OR 90ºC CU WIRE

DO NOT OPEN UNDER LOAD

Rated: 600V, 30A 50/60Hz

200kA RMS SYM 3W

Indication Min Voltage: 90V

IEC: 60269-2 32A

 690Vac 120kA 3W

Degree of Protection IP20

Series: CHM

4

MADE IN

CHINA

R

GB13539

Rated: 600V, 30A 50/60Hz

200kA RMS SYM

Indication Min Voltage: 90V

Degree of Protection IP20

MADE IN

CHINA

Series: CHCC

430P

1

USE CLASS CC FUSE

75ºC OR 90ºC CU WIRE

DO NOT OPEN UNDER LOAD

Wire Range

Conductor

No. of

Torque

Type

Conductors

18-14 AWG

20 in-lbs

(0.8-2.0mm

2

)

Single

2.3 Nm

18-16 AWG

25 in-lbs

(0.8-1.3mm

2

)

Solid,

Dual

2.8 Nm

14-10 AWG

Stranded

(2.0-5.2mm

2

)

12-10 AWG

(3.3-5.2mm

2

)

8-4 AWG

Stranded,

30 in-lbs

(8.3-21.1mm

2

)

Fine

3.4 Nm

Stranded

18-14 AWG

Spade

Single

(0.8-2.0mm

2

)

Terminal

N/A

Comb Bus

GB13539

4GY1

UL4248-18

Rated: 1000Vdc, 30A 33kA RMS SYM

Indication Min Voltage: 90V

IEC: 60269-1 32A

1000Vdc 33kA 3.5W

Degree of Protection IP20

MADE IN

CHINA

Series: CHPV

5

R

Wire Range

Conductor

No. of

Torque

Type

Conductors

18-14 AWG

20 in-lbs

(0.8-2.0mm

2

)

Single

2.3 Nm

18-16 AWG

25 in-lbs

(0.8-1.3mm

2

)

Solid,

Dual

2.8 Nm

14-10 AWG

Stranded

(2.0-5.2mm

2

)

12-10 AWG

(3.3-5.2mm

2

)

8-4 AWG

Stranded,

30 in-lbs

(8.3-21.1mm

2

)

Fine

3.4 Nm

Stranded

18-14 AWG

Spade

Single

(0.8-2.0mm

2

)

Terminal

N/A

Comb Bus

USE PHOTOVOLTAIC 10X38 FUSE

75ºC OR 90ºC CU WIRE

DO NOT OPEN UNDER LOAD

GB13539

Rail Mount Fuse Blocks and Holders

Multi-Pole Ganging

Use multi-pole connection kit part number 
JV-L to gang multiple poles together. One 
JV-L kit is sufficient to gang up to 4 poles.

4mm
Lockout
Feature in
Fuse Carrier

Toolless
Ganging of
Multiple
Poles

Toolless DIN Rail
Mounting

Wire Strip
Length
Indicator

6mm Wire
Clamp Lug and
open bus bar
connection
(#4 to #18)

Captive, Fully
Backed Out
Phil-Slot Screw

Spade lug 
connection

Self-Extinguishing,
UL 94V0 Rated
Polyester
Material

Label Slot

Optional
Open Fuse
Indicator

Hole for Wire
Security Tag

Features

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

276

Fuse Holders and Blocks

Rail Mount Fuse Blocks and Holders

Dimensional Data - mm (in)

17.5

[ 0.689 ]

35

[ 1.378 ]

52.5

[ 2.067 ]

70

[ 2.756 ]

73.88 [ 2.909 ]

42.58

[ 1.676 ]

52.83

[ 2.080 ]

61.83

[ 2.434 ]

18.59

[ 0.732 ]

83.19

[ 3.275 ]

9

[ 0.354 ]

7.0

[ 0.276 ]

Removing Instructions

1. Press down on top 

of DIN-Rail

2. Rotate out

on the bottom

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

277

Fuse Holder

s

& Blocks

Global Modular Fuse Holders

For additional information see reorder #3185

Fuse Holders and Blocks

Catalog Numbers

Max

No. of

Without

With*

Voltage

17.5mm

Indication

Indication

Size

& Current

IEC

UL

Phase Configuration

Modules Wire Range

Maximum Torque 

CH081D

CH081DI

1-pole

1

1-16mm

2

(18-8 AWG)

2.5 N•m (22LB-In)

CH081DNX

-

1 Neutral Pole

1

CH081DNS

CH081DNSI

1-pole + Neutral

1

1-10mm

2

(18-8 AWG)

2.0 N•m (17.5LB-In)

CH081DN

CH081DNI

CH08

IEC

1-pole + Neutral

2

CH082D

CH082DI

8x32

400Vac

2-pole

2

CH083D

CH083DI

25A

3-pole

3

1-16mm

2

(18-8 AWG)

2.5 N•m (22LB-In)

CH083DNS

CH083DNSI

3-pole + Neutral

3

CH083DN

CH083DNI

3-pole + Neutral

4

CH084D

CH084DI

4-pole

4

CHM1DU

CHM1DIU

*

1-pole

1

CHM2DU

CHM2DIU

UL

*

2-pole

2

CHM3DU

CHM3DIU

CHM

600V/30A;

*

3-pole

3

CHM4DU

CHM4DIU

10X38

IEC

*

4-pole

4

CHM1DNU

CHM1DNIU

and

690V/32A

*

1-pole + Neutral

2

CHM3DNU

CHM3DNIU

Midget

*

3-pole + Neutral

4

1-21mm

2

(18-4 AWG)

3.4 N•m (30LB-In)

UL 48Vdc/30A;

CHM1DI-48U

IEC

*

1-pole

1

48Vdc/32A

CHM1DNXU

IEC 690V32A

1-pole + Neutral

2

CHPV1U

CHPV1IU

CHPV

UL & IEC;

†††

1-pole

1

CHPV2U

CHPV2IU

1000Vdc/30A

†††

2-pole

2

CHCC1DU

CHCC1DIU

**

1-pole

1

CHCC2DU

CHCC2DIU

CHCC

UL

**

2-pole

2

1-21mm

2

(18-4 AWG)

3.4 N•m (30LB-In)

CHCC3DU

CHCC3DIU

Class CC

600V/30A

**

3-pole

3

CHCC1DI-48U

UL 48Vdc/30A

**

1-pole

1

CH141D

CH141DI

1-pole

1.5

CH141DMS

-

UL

1-pole + Microswitch

1.5

CH141DNX

-

600Vac/dc

1 Neutral Pole

1.5

CH141DN

CH141DNI

40A

1-pole + Neutral

3

CH142D

CH142DI

CH14

(5 Watt)

2-pole

3

2.5-16mm

2

(14-6 AWG)

3.0 N•m (26LB-In)

CH143D

CH143DI

14x51

IEC

3-pole

4.5

CH143DMS

-

690Vac,

3-pole + Microswitch

4.5

CH143DN

CH143DNI

50A

3-pole + Neutral

6

CH143DNMS

-

3-pole + Neutral + Microswitch

6

CH144D

CH144DI

4-pole

6

CH221D

Not

1-pole

2

CH221DMS

Available

1-pole + Microswitch

2

CH221DNX

with

UL

1 Neutral Pole

2

CH221DN

local

600Vac/dc,

1-pole + Neutral

4

CH222D

neon

CH22

100A

2-pole

4

2.5-50mm

2

(14-1 AWG)

4.0 N•m (35LB-In)

CH223D

indication

22x58

(9.5 Watt)

3-pole

6

CH223DMS

(remote

IEC

3-pole + Microswitch

6

CH223DN

microswitch

690Vac,

3-pole + Neutral

8

CH223DNMS

only)

125A

3-pole + Neutral + Microswitch

8

CH224D

4-pole

8

Class J

Neon

easy

ID™ Indication

Indication

CH30J1

CH30J1I

CH30J

UL/CSA

††

1-pole

1-50mm

2

(18-1 AWG)

1-8 AWG 4.0 N•m (35LB-In)

CH30J2

CH30J2I

30A

600Vac

††

2-pole

10-18 AWG 2.7N•m (24LB-IN)

CH30J3

CH30J3I

Class J

††

3-pole

CH60J1

CH60J1I

CH60J

UL/CSA

††

1-pole

1-50mm

2

(18-1 AWG)

1-8 AWG 4.0 N•m (35LB-In)

CH60J2

CH60J2I

60A

600Vac

††

2-pole

10-18 AWG 2.7N•m (24LB-In)

CH60J3

CH60J3I

Class J

††

3-pole

† UL Recognized (cURus)

†† UL LIsted (cULus)

††† UL Recognized, Standard 4248-18, CSA

For further details see Data Sheets 2053 (CH08, CHM, CHCC, CH14 AND CH22) and 2144 (CHJ Class J)
*90V miminum required for illumination
***12V mininum required for illumination

8x32 IEC

14x51 IEC

22x58 IEC

PV

UL

IEC

Class J 30A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

278

Global Modular Fuse Holders - Remote Fuse Monitoring
Accessory CH-PLC

Fuse Holders and Blocks

Specifications:

Power Input

: 24Vdc / 5mA

Sensing Voltage

: 600V/30mA

Output Signals

: Digital 0Vdc (Low), 24Vdc (High)

- 0Vdc Low – Fuse is good

- 24Vdc High – Fuse has opened

When the fuse opens, the output signal is sent high and will
remain high until the unit is reset

Rated Impulse Voltage

: 8kV

Local Indication

: Two distinct LEDs indicate unit power (green)

and open fuse (red). Upon the replacement of the fuse, the
actuation of the reset switch will reset the open
fuse LED

Flammability Rating

: UL 94V0

Wiring:

• For power, signal and ground connections use 22-24AWG

(0.25mm

2

) 300V rated wire

Emissions and Immunity Testing:

• Electrostatic Discharge IEC 61000-4-2

• Electrical Fast Transient/Burst IEC 6100-4-4

• Surge Immunity IEC61000-4-5

Packaging:

• The CH-PLC is packaged individually

• A single unit monitors up to three phases 

•  Package includes 0.11” (2.8mm) quick connects for power, signal

and ground connections

Minimum Circuit Voltage:

• Minimum circuit voltage required across the CH holder is 100Vac

for the remote indication device to operate

Installation Technique:

• Mounts on the left side of the fuse holder and mechanically 

interlocks with the fuse holder switch handle with hardware 
provided

IP20 Rating:

Yes

Environmental Data:

• Storage and Operating Temperature: -20°C to 75°C

Agency Information:

• UL 508

• cULus to CSA Standard 22.2 No.14

PLC Programming:

• The CH-PLC signal line is designed to provide a digital input to a

PLC I/O card.

•  Programmable Logic Control program must be written to properly

interpret the input signal to the PLC.

•  The PLC program should check for consecutive high signals

before taking action on a critical process.

De-energize all circuits before installing or removing any CH-PLC devices and follow all prescribed safety procedures.

Make it Simple with
Bussmann resettable
three-phase remote fuse monitor
that integrates with a
Programmable Logic Controller
(PLC) or other monitoring and
control equipment.

For additional information see reorder #3185

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

279

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Global Modular Fuse Holders - Comb-Bus Bar
Specifications and Selection Guide

Specifications

Agency Information:

UL 508, File E195399

Pitch: 

17.8mm

SCCR: 

10kA (default)

100kA (with upstream Class J 200A fuses)

Max Current: 

100A (power feed from end;

200A (power feed from center)

Max Voltage: 

600Vac/dc (three phase)

1000Vdc/600Vac (single phase)

Features and Benefits

• Easily distribute power in single-phase or three-phase 

configurations

• Flexible cut-to-length solutions without compromising on the

product’s finger-safe features

• 100kA SCCR (Short-Circuit Current Rating) when protected

by a 200A Class J fuse

• Single-phase bus bars rated to 1000Vdc and 100A in end-fed

configuration (200A for center-fed configuration)

• Three-phase bus bars rated to 600Vac/dc and 100A in 

end-fed configuration (200A for center-fed configuration)

• Power feed terminals for single-phase and three-phase 

service

Part Number

Description

BB1P100M3

Single-phase 1000Vdc busbar, 100A, 3 pins, assembled endcap

BB1P100M6

Single-phase 1000Vdc busbar, 100A, 6 pins, assembled endcap

BB1P100M9

Single-phase 1000Vdc busbar, 100A, 9 pins, assembled endcap

BB1P100M12

Single-phase 1000Vdc busbar, 100A, 12 pins, assembled endcap

BB1P100M15

Single-phase 1000Vdc busbar, 100A, 15 pins, assembled endcap

BB1P100M57

Single-phase 1000Vdc cuttable busbar, 100A, 57 pins, without endcap

BB3P100M6

Three-phase 600V busbar, 100A, 6 pins, assembled endcap

BB3P100M9

Three-phase 600V busbar, 100A, 9 pins, assembled endcap

BB3P100M12

Three-phase 600V busbar, 100A, 12 pins, assembled endcap

BB3P100M15

Three-phase 600V busbar, 100A, 15 pins, assembled endcap

BB3P100M57

Three-phase 600V cuttable busbar, 100A, 57 pins, without endcap

ECAP1P

Single-phase busbar endcap

ECAPMP

Three-phase busbar endcap

PWR35MM

35mm

2

feeder terminal for three-phase busbar (115A, 1000Vac/dc)

FSCVR

Spare contact safety protection covers

PWR1PLP

Single-phase low-profile feeder terminal (115A, 1000Vac/dc)

PWR50MM

50mm

2

direct feed terminal (1000Vac/dc)

Selection Guide

For additional information see reorder #3185

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

280

Fuse Holders and Blocks

Global Modular Fuse Holders - Comb-Bus Bar Features
and Installation Guide

For additional information see reorder #3185

Typical Dimensional Data

Three-phase

Single-phase

ECAP1P

ECAPMP

FSCVR

PWR1PLP

PWR35MM

PWR50MM

Typical Installation Example

Power Feed Terminals

Comb-Bus Bar

Modular Fuse Holders

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

281

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Class J Modular Fuse Holders

CH _ _ J _

Specifications
Description:

IP20 finger-safe, 1- to 3-pole Class J fuse 

holder with DIN-Rail or panel mounting.

Ratings:

Volts: — 600Vac/dc (or less)

Amps: — 30A (30A version)

— 60A (60A version)

SCCR: — 200kA

Wire Range:

Cu solid and stranded conductors with single

(1-18AWG) and dual (3-18AWG) wire ratings. See Catalog
Numbers table for details.

Torque Rating:

10-18AWG 24 lb-in.

1-8AWG 35 lb-in.

Poles:

1-, 2- or 3-Pole.

Storage & Operating Temperature Range*:

-20°C to 75°C.

Agency Information:

CE, UL 4248/CSA 22.2 No. 4248.P

UL Listed, Guide IZLT, File E14853.

Flammability Rating:

UL 94V0.

Catalog Numbers

See Catalog Numbers table below.

Features and Benefits

• Choice of local fuse indication; 

easy

ID™ viewing window (for 

seeing indicator on LPJ-SPI indicating fuse) or neon lamp.

• Versatile 1-, 2- and 3-pole versions for 0-30A and 35-60A 

fuses with dual wire rated connections simplify wiring.

• Improved electrical safety with IP20 finger-safe construction 

with lock-out/tag-out feature. 3-phase fuse extraction 
assures all phases are opened for service work.

• Flexible panel/35mm DIN-Rail mounting mounting options

*For fuse selection on applications above or below 25ºC, consult derating charts in

Bussmann publication “Selecting Protective Devices” (SPD).

Catalog Numbers

Catalog

# of

Local

Amp

Volts

IP20

AWG Single

Numbers

Poles

Indication

Rating (AC/DC) Finger-Safe Wire Range

Padlockable

Mounting

CH30J1

1

easy

ID**

CH30J1I

1

Neon Lamp***

CH30J2

2

easy

ID**

30

600

Yes

1-18

Yes

35mm DIN/ Panel

CH30J2I

2

Neon Lamp***

CH30J3

3

easy

ID**

CH30J3I

3

Neon Lamp***

CH60J1

1

easy

ID**

CH60J1I

1

Neon Lamp***

CH60J2

2

easy

ID**

60

600

Yes

1-18

Yes

35mm DIN/ Panel

CH60J2I

2

Neon Lamp***

CH60J3

3

easy

ID**

CH60J3I

3

Neon Lamp***

** 

easy

ID™ viewing window, requires use of Bussmann LPJ_SPI permanent indication fuses.

*** Indication non-fuse dependent, minimum voltage 90Vac/115Vdc.

Dimensions (mm):

30 Amp Version

60 Amp Version

Data Sheet: 2144

Fuse Size

Poles

W

D

H

1

32

70

115

0-30A

2

64

70

115

3

96

70

115

1

40

83

125

35-60A

2

80

83

125

3

120

83

125

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

282

Fuse Holders and Blocks

Optima

Fuse Holder Module and Disconnect Switch 

4.25

 

(

±

 0.03)

(108.0mm) (

±

 0.76) 

(6.9mm)

(18.8mm)

(7.9mm)

BUSS

5.72

 

(

±

 .045)

(145.3mm) (

±

 1.14) 

0.43

 

(

±

 0.03)

(10.9mm) (

±

 0.76) 

1.38

(35.0mm)

0.23

1.86

(5.8mm)

3.17

(80.5mm) 

1.312

(

±

 0.01)

(33.3mm)

(

±

 0.25)

Panel Mounting

Hole Pattern

(47.2mm)

Panel Mounting
Hole Pattern

3.74

 

(

±

 0.03)

(95.0mm)  (

±

 0.76) 

0.57

 

(

±

 0.03)

(14.5mm) (

±

 0.76) 

0.27

0.31

Communication
Port

0.74

0.50

 

(12.7mm)

Communication
Port

0.44

 

(11.2mm)

2T1

1L1

3L2

5L3

4T 2

6T3

1.76

3.60

(91.4mm)

(44.7mm)

0.224

(5.6mm)

Data Sheet: 1103

Specifications
Description:

3-pole load break modular fuse holder and 

disconnect switch  for 

13

32

x 1

1

2

˝ (10 x 38mm) fuses.

Dimensions:

See Dimensions illustration.

Poles:

3

Agency Information:

CE, UL (see table), CSA Certified,

C22.2 No. 39, Class 6225-01, File 47235, IEC (see table).

Flammability Rating:

UL 94V0.

Horsepower Rating of Switch

Volts

240

480

600

3-Phase

HP

5

10

15

Recommended Fuse Types

Class CC

Midget (Non-Rejection)

European

LP-CC

KTK

C10M

KTK-R

FNM

C10G

FNQ-R

FNQ

Physical Characteristics

•  Small size matches 45mm IEC starter width
•  Accepts #8-18 AWG stranded, #10-18 AWG solid wire
•  3-pole
•  Handle and shaft required for through the door operation

Features/Benefits

•  Padlockable with finger-safe terminals for safety. Qualified

as IP20 per IEC 60529.

•  Cam-action handle for easy module removal, offered with

Class CC rejection clips or European 10 x 38mm clips to
meet global needs

•  Wire ready with 35mm DIN-Rail or screw panel mounting 

(#8 screw, 1

1

4

” long) saves installation time

•  Fuse indication lights with option for remote fuse status

available. See Data Sheet for additional wiring details.

Typical Applications

• Industrial Control
• Process Control Systems
• Automated Warehouse Systems
• Individual Control Circuits

Dimensions

Catalog Numbers

Catalog

SCCR**

Remote Open

UL Information

Numbers

Electrical Rating

Rating

Clips

Fuse Indication

Std.

File

Guide

IEC

CE

OPM-1038SW

30A, 600Vac UL/CSA

Non-rejection,

No

Recognized

*

10x38mm or

32A, 660Vac IEC

13

32

” x 1 

1

2

UL 508

E161278

NLRV2

IEC 60947-3

Yes

OPM-1038RSW

30A, 600Vac UL/CSA

100kA

Rejection,

No

Listed

Class CC

UL 508

E161278

NLRV

Yes

OPM-1038SWC

30A, 600Vac UL/CSA

Non-rejection,

Yes

Recognized

*

10x38mm or

32A, 660Vac IEC

13

32

” x 1 

1

2

UL 508

E161278

NLRV2

IEC 60947-3

No

OPM-1038RSWC

30A, 600Vac UL/CSA

100kA

Rejection,

Yes

Listed

Class CC

UL 508

E161278

NLRV

No

*Rating varies depending on fuse used in module; 100kA maximum
**Short-Circuit Current Rating

O P M -

1

0 3

8

S W

Series

Fuse Type

Communication

C

=

Communication
Feature

Catalog Number Build-A-Code

OPM-1038 With Disconnect Switch

Blank

= 10 x

38mm or 

13

32

” x 1-

1

2

R

= Class CC

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

283

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Optima

Fuse Holder Module

BUSS

3.74

 

(

±

 0.03)

(95.0mm)

(

±

 0.76)

0.57

(14.5mm)

0.23

(5.8mm)

3.17

(80.5mm)

3.22

 (

±

 0.03)

0.27

0.31

(81.8mm) (

±

 0.76)

3.60

 (

±

 0.03)

  (91.4mm) (

±

 0.76)

1.76

 (

±

 0.03)

(44.7mm) (

±

 0.7 )

1.65

 

(

±

 0.03)

(41.9mm) (

± 0

.76)

1.312

 

(

±

 0.01)

(33.3mm)

(

±

 0.25)

Panel Mount
Hole Pattern

1.86

 

(

±

 0.03)

(47.2mm)

(

±

 0.76)

Panel Mount
Hole Pattern

3.60

 

(

±

 0.03)

(91.4mm) (

±

 0.76)

Communication
Port

0.74

Communication
Port

(6.9mm)

(18.8mm)

(7.9mm)

0.50

 

(12.7mm)

0.44

 

(11.2mm)

2T1

4T2

6T3

IL1

3L2

5L3

0.224"

(5.6mm)

Data Sheet: 1102

Specifications
Description: 

3-pole modular fuse holder for 

13

32

” x 1 

1

2

” 

(10 x 38mm) fuses.

Dimensions:

See Dimensions illustration.

Poles:

3

Agency Information:

CE, UL (see table), CSA Certified,

C22.2 No. 4248, Class 6225-01, File 47235, IEC (see table).

Flammability Rating:

UL 94V0.

Recommended Fuse Types

Class CC

Midget (Non-Rejection)

European

LP-CC

KTK

C10M

KTK-R

FNM

C10G

FNQ-R

FNQ

Physical Characteristics

•  Small size matches 45mm IEC starter width
•  Accepts #8-18 AWG stranded, #10-18 AWG solid wire
•  3-pole

Features/Benefits

•  Padlockable with finger-safe terminals for safety. Qualified

as IP20 per IEC 529.

•  Cam-action handle for easy module removal. 
• Offered with Class CC rejection clips or European 10 x

38mm clips to meet global needs

•  Wire ready with 35mm DIN-Rail or screw panel mounting 

(#8 screw, 1 

1

4

˝ long) saves installation time

•  Fuse indication lights with option for remote fuse status

indication. See Data Sheet for additional wiring details.

Typical Applications

• Industrial Control
• Process Control Systems
• Automated Warehouse Systems
• Individual Control Circuits

Dimensions

O P M

-

1

0

3

8

Series

Fuse Type

Communication

C =
Communication
Feature

Blank

= 10 x

38mm or 

13

32

˝ x 1 

1

2

˝

R

= Class CC

Catalog Number Build-A-Code

OPM-1038

Catalog Numbers

Catalog

SCCR**

Remote Open

UL Information

Numbers

Electrical Rating

Rating

Clips

Fuse Indication

Std.

File

Guide

IEC

CE

OPM-1038

30A, 600Vac/dc UL/CSA

Non-rejection,

No

Recognized

E14853

IZLT2

IEC 60269-2-1

Yes

(Max 3 Watts per fuse)

*

10 x 38mm or

UL 4248

32A, 660V IEC

13

32

˝ x 1 

1

2

˝

OPM-1038R

30A, 600Vac/dc UL/CSA

200kA

Rejection,

No

Listed

E14853

IZLT

Yes

Class CC

UL 4248

OPM-1038C

30A, 600Vac/dc UL/CSA

Non-rejection,

Yes

Recognized

E14853

IZLT2

IEC 60269-2-1

No

(Max 3 Watts per fuse)

*

10 x 38mm or

UL 4248

32A, 660V IEC

13

32

˝ x 1 

1

2

˝

OPM-1038RC

30A, 600Vac/dc UL/CSA

200kA

Rejection,

Yes

Listed

E14853

IZLT

No

Class CC

UL 4248

*Rating varies depending on fuse used in module; 200kA maximum.

**Short-Circuit Current Rating

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Fuse Holder Wire Range:

— 75°Cu Only
— #18-12 Single/Dual, torque 15lb-in
— #10-8

Single/Dual, torque 20lb-in

— Dual wire with same gauge and type  

AWu

[mm2]

(N•m)/lb-in

Solid

#18-8 x 1

1-6 x 1

18-12 Single/Dual

#18-8 x 2

1-6 x 2Strld

#18-8 x 1

1-6 x 1

#18-8 x 2

1-6 x 2

10-8 Single/Dual

Ferrules

1-4 x 1

20in-lb (2.5 N•m)

1-4 x 2

Input Power Terminal Wire Range:

Wiring

Solid

(1) #14 to #2 (1.5 to 25mm

2

) conductor or

Conductor

(2) #14 to #6 (1.5 to 10mm

2

) conductors

Stranded

(1) #14 to #2 (1.5 to 25mm

2

) conductor or

Conductor

(2) #12 to #6 (2.5 to 10mm

2

) conductors

Tightening

Connector

20lb-in (2.2 N•m)

Torque:

Screw Clamp

15lb-in (1.7 N•m)

Materials:

— 

Housing:

Thermoplastic - ULV2

— 

Clip:

Tin-plated copper alloy

— 

Contact lubricant:

Fluoroether grease

— 

Saddle screw:

Plated steel

— 

DIN rail springs:

Stainless steel

Optional Accessories:

Comb Bar (Max current rating = 63A)

GV2G245A46

2 circuit, 45mm between same phases

GV2G254A46

2 circuit, 54mm between same phases

GV2G272A46

2 circuit, 72mm between same phases

GV2G345A46

3 circuit, 45mm between same phases

GV2G354A46

3 circuit, 54mm between same phases

GV2G445A46

4 circuit, 45mm between same phases

GV2G454A46

4 circuit, 54mm between same phases

GV2G472A46

4 circuit, 72mm between same phases

GV2G554A46

5 circuit, 54mm between same phases

Input Terminal Block (Max current rating = 63A)

GV2G05

Input/Feed Through Power Terminal, Supports feed through to

another system, DIN-Rail mount only

GVG09

Input Power Terminal

Cover

GV1G10

Protective Cover for unused terminals on comb bar

Auxiliary Contacts

GVAE11

NO/NC

GVAE20

NO/NO

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

284

Fuse Holders and Blocks

Optima

Three-pole Overcurrent Protection Module

Data Sheet: 1109

Specifications
Description:

OPM-NG-SC3:

3-pole Class CC fuse holder for use with

Class CC fuses (Bussmann Types LP-CC,
FNQ-R, KTK-R).

OPM-NG-SM3:

3-pole fuse holder for use with 

13

32

˝ x 1

1

2

˝ and

10.3 x 38mm fuses (Bussmann Types: 

13

32

˝ x 1

1

2

˝; KTK, FNQ, KLM, 10 x 38mm;

FWA, FWC, C10G_ _, C10M_ _).

Ratings:

Volts: — OPM-NG-SC3: 600Vac (or less)

— OPM-NG-SM3: 600Vac (or less) UL and CSA 30A

— OPM-NG-SM3: 690Vac (or less) IEC 32A

Amps: — OPM-NG-SC3: 0-30A

— OPM-NG-SM3: 0-30A

SCCR:— OPM-NG-SC3: 200kA

— OPM-NG-SM3: Same as fuse IR, 200kA maximum

Agency Information:

CE, UL; OPM-NG-SC3 UL Listed, UL

4248, File E14853, Guide IZLT. OPM-NG-SM3, UL
Recognized, UL 4248, File E14853, Guide IZLT2. CSA
Certified, C22.2 No. 4248, Class 6225-01, File 47235. IEC
60947-3 Utilization Category AC20B.

Handling & Storage Temperature:

-10° to 65°C.

Features/Benefits

• 45mm width matches IEC starters 
• 35mm DIN-Rail or panel mounting feature. Maximum screw

size #8 (M4)

• Pressure plate terminations with dual-wire rated terminals

(see Wire Table) and optional auxiliary contacts

• Integrated collapsible handle and fuse carrier cannot be

removed from holder base

• Padlockable and IP20 finger-safe to IEC60529

Typical Applications

• Mass Produced Control Systems
• Process Control Systems
• Automated Warehouse Systems
• Individual Control Circuits

OPM-NG-

75º Cu Only

AWG

[mm2]

(N•m)/lb-in

Solid

#18-8 x 1

1-6 x 1

18-12 Single/Dual

#18-8 x 2

1-6 x 2

15lb-in (1.7 N•m)

Stranded

#18-8 x 1

1-6 x 1

#18-8 x 2

1-6 x 2

10-8 Single/Dual

Ferrules

1-4 x 1

20lb-in (2.5 N•m)

1-4 x 2

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

285

Optima

Three-pole Overcurrent Protection Module

Fuse Holder

s

& Blocks

Data Sheet: 1109

Optional Accessories

Dimensions 

- mm (± 0.38) / in (± .015)

Fuse Holders and Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

286

Fuse Holders and Blocks

Class J (Finger-safe) Fuse Holders

Data Sheet: 1152

30 Amp Version

60 Amp Version

• Short-Circuit Current Rating of 300kA with Bussmann

LPJ___SP fuses.

• Rapid, flexible 35 mm DIN-Rail mounting.
• One piece interlocking design for assembling multiple pole

blocks reduces inventory costs.

• Removable fuse carrier allows fuse replacement away from

base while maintaining finger-safe rating.

Typical Applications

• Industrial Controls
• Process Controls
• Small HP VFDs

Catalog Numbers

Catalog Numbers

Amps

Indication

JT60030

30

Non-indicating

JT60060

60

Non-indicating

JTN60030

30

Indicating (Neon)

JTN60060

60

Indicating (Neon)

Safety J™ — JT(N)60030 & JT(N)60060

Specifications
Description:

Indicating and non-indicating finger-safe, 

DIN-Rail mount fuse holders for use with Class J fuses -
(Bussmann LPJ, JKS).

Dimensions:

See Dimensions illustrations.

Ratings:

Volts: — 600Vac

Amps: — 0-60A (JT(N)60060)

— 0-30A (JT(N)60030)

SCCR:— 200kA RMS Sym.

— 300kA self certified using Bussmann LPJ_SP fuses

Agency Information:

CE, Listed to UL 4248:  Guide IZLT,

File 14853, CSA Certified:  Class 6225-01, File 47235. IP20
per IEC 60529.

Flammability Rating:

UL 94V0.

Indication:

Min voltage: 90Vac, 115Vdc; neon lamp “ON”

when fuse opens, voltage source and current path are 
present.

Terminations:

30A dual port torque 20lb-in, 60A single port

torque 45lb-in, terminal construction, tin-plated copper alloy.

Wire Size:

JT(N)60030 - rated for 75°C, AWG#18-#8; Cu

only, JT(N)60060 - rated for 75°C, AWG#14-#4; Cu only.

(Note: For JT(N)60030 use both stranded or solid, in a variety of dual wire combinations of
same wire size and type.)

Features and Benefits

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

287

Fuse Holder

s

& Blocks

Class J (Finger-safe) Fuse Holders

JT(N)600 Series fuse blocks can be dovetailed together within the same current rating to provide multiple pole block
configurations.

NOTE: JT(N)60030 cannot be dovetailed to JT(N)60060.

3.10

(78.7)

3.06

(77.7)

1.31

(33.3)

1.25

(31.8)

Din-rail

Slot

MOUNTING

Shown without fuse

pullout cover

4.40

(111.7)

2.96

(75.2)

1.52

(38.1)

.10

(2.6)

BUSS

BUSS

35 – 60A
600VAC

USE CLASS J

FUSES

DO NOT REMOVE

UNDER LOAD

 

JT60060

BUSS

BUSS

35 – 60A
600VAC

USE CLASS J

FUSES

DO NOT REMOVE

UNDER LOAD

 

JT60060

BUSS

BUSS

35 – 60A
600VAC

USE CLASS J

FUSES

DO NOT REMOVE

UNDER LOAD

 

JT60060

1 pole

2 pole

3 pole

Data Sheet:  1152

Dimensions for JT60060 & JTN60060 — in (mm)

1.14

(29.0)

1.05

(26.7)

Slot

MOUNTING

Shown without fuse

pullout cover

BUSS

BUSS

0 – 30A

600VAC

USE CLASS J

FUSES

DO NOT REMOVE

UNDER LOAD

 

JT60030

BUSS

BUSS

0 – 30A

600VAC

USE CLASS J

FUSES

DO NOT REMOVE

UNDER LOAD

 

JT60030

BUSS

BUSS

0 – 30A

600VAC

USE CLASS J

FUSES

DO NOT REMOVE

UNDER LOAD

 

JT60030

3.60

(91.4)

2.42

(61.3)

1.23

(31.2)

.07

(1.8)

1 pole

2 pole

3 pole

2.75

(69.9)

2.52

(64.1)

Din-rail

Dimensions for JT60030 & JTN60030 — in (mm)

Fuse Holders and Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

288

Fuse Holders and Blocks

SAMI™ Fuse Covers

Specifications
Description:

Indicating and non-indicating fuse covers for

Class J, RK1, RK5, H, K5, CC, G (0-30A) and midget-type
fuses. Indicating feature requires a minimum of 90Vac or
115Vdc to illuminate lamp. One cover required for each pole.

WARNING:

To avoid electrical shock, turn power off before

installing, removing or servicing.

Dimensions: 

See Dimensions illustration.

Ratings:

Volts: — Non-Indicating

- 0-600Vac/dc

— Indicating

- 90 to 600Vac

-115 to 600Vdc

Amps: — 0-100A

Agency Information:

CE, UL Listed; SAMI-1I through

SAMI-6I, SAMI-8I and SAMI-9I, SAMI-1N through SAMI-6N,
SAMI-8N and SAMI-9N, UL Recognized; Guide JDVS2, File
E58836, SAMI-7I and SAMI-7N, CSA Certified, 
File LR47235-93C.

Catalog Numbers

Catalog

Dimensions - in

Numbers*

Description

A

B

C

SAMI-1_

600V, J (0-30A) and 600V, T (35-60A)**

5.02

1.03

1.94

250V, RK, K5, H (35-60A)

SAMI-2_

600V, RK, K5, H (0-30A)

7.03

1.30

2.07

SAMI-3_

600V, J (65-100A)

7.03

1.30

2.33

SAMI-4_

250V, RK, K5, H (65-100A)

8.20

1.30

2.18

SAMI-5_

600V, RK, K5, H (35-60A)

8.20

1.30

2.18

SAMI-6_

600V, J (35-60A)

4.98

1.17

2.14

SAMI-7_

600V, Midget, Class CC, G (0-30A)

3.82

0.75

1.72

SAMI-8†_

600V, RK††, K5, H (65-100A)

10.38

1.50

2.33

SAMI-9_

250V, RK, K5, H (0-30A) and 600V,

3.82

0.75

1.72

T (0-30A)

*For indicating cover, add suffix “I”, for non-indicating cover, add suffix “N”.
Example: SAMI-7I = Indicating, SAMI-7N = Non-indicating.
**Available in non-indicating only.
†SAMI-8A adapter available for small Fusetron

body design. SAMI-8I and SAMI-8N come

standard with adapter (SAMI-8A).
††Not for use with KTS-R fuses.

Features and Benefits

• Insulated cover allows field conversion of fuses mounted in

open fuse blocks to dead front configuration.

• Optional open fuse indicating light aids in system

troubleshooting.

• Units are re-usable.
• Allows visual marking of line and load side of fuses.

Typical Applications

• Class H, R and J fuse blocks up to 100A
• Class T fuse blocks up to 60A
• Class CC, G and Midget, 30A fuse blocks

Dimensions

LINE

Buss

SAMI

 -2

LOAD

TEST PROBE

TEST PROBE

C

B

A

FUSE

Data Sheet: 1204  (Trimming Guides: 12041, 12042, 12043, 12044, 12045, 12046, 12048, 12049)

SAMI-1I

SAMI-3I

SAMI-4I

SAMI-2I

SAMI-6I

SAMI-8I

SAMI-7I

SAMI™ Series

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

289

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Modular Knifeblade Fuse Blocks

Class R, H(K), & J Applications up to
600 Amps

Specifications

Ratings:

Volts: — 250V, 600V

Amps: — 70-600A

SCCR: — 200kA (Class R & J) 

10kA (Class H & K)

Agency Information:

Blocks:

UL - Listed cULus 
E14853 – IZLT & IZLT7
CSA - Certified 47235 – 
6225-01

Covers:

UL - Listed UL 
E58836 – JDVS2
CSA - Certified 47235 – 
6225-01

Flammability Ratings:

Blocks:

UL 94V0, self-extinguishing

Covers:

UL 94HB, self-extinguishing

Operating & Storage Temperature Range:

Blocks

-40ºC to 120ºC

Covers

non-indicating covers -40ºC to 120ºC
indicating covers -20ºC to 90ºC

Materials:

Base – Thermoplastic
Box Lug – Tin-plated aluminum

Wire:*

Cu/Al – 75ºC/90ºC (100 - 200A)
Cu/Al – 75ºC only (400 - 600A)

*Higher temperature rated wire can be used with appropriate derating.

Features and Benefits

•  Integral dovetails allow snapping together multiple poles at

point-of-use for greater application flexibility

•  Factory assembled two- and three-pole configurations 

available

•  Up to four mounting holes per pole increase installation 

flexibility

•  Standard phase barriers between poles for additional safety

•  Design meets UL creep and clearance requirements for

Industrial Control Circuits (UL 508 and UL 845)

•  200 to 600A blocks meet the higher UL creep and clearance 

requirements for Industrial Power Distribution Standards 
(UL 98, UL 69, UL 489, UL 891 and UL 869A)

•  Optional IP20 finger-safe covers available on entire

knifeblade fuse block product line:

– High-clarity see-through covers allow for inspecting wire 

terminations or thermography measurements without 
removing cover

– Probe holes included for easy, safer testing and 

troubleshooting

– Built-in lockout/tagout feature improves safety

•  Standard fuse clip reinforcing springs enhance electrical

contact

Typical Applications

• Critical power, factory automation, renewable energy

,

HVAC, building/elevator  controls, building entrance,
process industries

Scan this tag to get the

latest product information for the

Modular Knifeblade Fuse Blocks.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

290

Fuse Holders and Blocks

Modular Knifeblade Fuse Blocks Part Number Table

Catalog Number

Covers* 

Fuse Range

Number

Wire Range

Wire Range

Torque

Cooper Bussmann

Class H(K)

Class R

w/o Indication

w/ Indication

Volts

(amps)

of Poles

(solid and stranded)***

(fine stranded Cu)

N•m (Lb-in)

Fuses

HM25100-1CR RM25100-1CR

1

1-3 AWG

6.2 (55)

70-

1/0-3 AWG; (2) Cu 4-6 AWG

4-6 AWG

5.6 (50)

Class H(K):

HM25100-2CR RM25100-2CR CVR-RH-25100 CVRI-RH-25100

100

2

4-6 AWG; (2) Cu 8 AWG

8 AWG

5.1 (45)

NON

HM25100-3CR RM25100-3CR

3

8 AWG; (2) Cu 10-14 AWG

4.5 (40)

Cu 10-14 AWG; Al 10-12 AWG

4.0 (35)

HM25200-1CR RM25200-1CR

110-

1

250 MCM-1 AWG

3/0-1 AWG

42 (375)

Class R:

HM25200-2CR RM25200-2CR CVR-RH-25200 CVRI-RH-25200

200

2

2-6 AWG; (2) Cu 2-6 AWG

2-6 AWG

31 (275)

LPN-RK_SP

HM25200-3CR RM25200-3CR

250

PN-RK_SPI**

HM25400-1CR RM25400-1CR

1

600kcmil

57 (500)

FRN-R

HM25400-2CR RM25400-2CR CVR-RH-25400 CVRI-RH-25400

225-

2

500kcmil-4 AWG

N/A

51 (450)

KTN-R

HM25400-3CR RM25400-3CR

400

3

(2) Cu 3/0 - 4 AWG

57 (500)

(2) Al 3/0 - 4 AWG

34 (300)

HM25600-1CR RM25600-1CR

450-

1

HM25600-2CR RM25600-2CR CVR-RH-25600 CVRI-RH-25600

600

2

(2) 500kcmil-4 AWG

N/A

51 (450)

HM25600-3CR RM25600-3CR

3

HM60100-1CR RM60100-1CR

1

1-3 AWG

6.2 (55)

HM60100-2CR RM60100-2CR CVR-RH-60100 CVRI-RH-60100

70-

2

1/0-3 AWG; (2) Cu 4-6 AWG

4-6 AWG

5.6 (50)

Class H(K):

100

4-6 AWG; (2) Cu 8 AWG

8 AWG

5.1 (45)

NOS

HM60100-3CR RM60100-3CR

3

8 AWG; (2) Cu 10-14 AWG

4.5 (40)

Cu 10-14 AWG; Al 10-12 AWG

4.0 (35)

HM60200-1CR RM60200-1CR

110-

1

250 MCM-1 AWG

3/0-1 AWG

42 (375)

Class R:

HM60200-2CR RM60200-2CR CVR-RH-60200 CVRI-RH-60200

200

2

2-6 AWG; (2) Cu 2-6 AWG

2-6 AWG

31 (275)

LPS-RK_SP

HM60200-3CR RM60200-3CR

600

PS-RK_SPI**

HM60400-1CR RM60400-1CR

1

600kcmil

57 (500)

FRS-R

HM60400-2CR RM60400-2CR CVR-RH-60400 CVRI-RH-60400

225-

2

500kcmil-4 AWG

N/A

51 (450)

KTS-R

HM60400-3CR RM60400-3CR

400

3

(2) Cu 3/0 - 4 AWG

57 (500)

KWS-R

(2) Al 3/0 - 4 AWG

34 (300)

PVS-R

HM60600-1CR RM60600-1CR

450-

1

HM60600-2CR RM60600-2CR CVR-RH-60600 CVRI-RH-60600

600

2

(2) 500kcmil-4 AWG

N/A

51 (450)

HM60600-3CR RM60600-3CR

3

Catalog Number

Covers* 

Fuse Range

Number

Wire Range

Wire Range

Torque

Cooper Bussmann

Class J

w/o Indication

w/ Indication

Volts

(amps)

of Poles

(solid and stranded)

(fine stranded) N•m (Lb-in)

Fuses

JM60100-1CR

1

1-3 AWG

6.2 (55)

2

1/0-3 AWG; (2) Cu 4-6 AWG

4-6 AWG

5.6 (50)

JM60100-2CR CVR-J-60100

CVRI-J-60100

70-

4-6 AWG; (2) Cu 8 AWG

8 AWG

5.1 (45)

JM60100-3CR

100

8 AWG; (2) Cu 10-14 AWG

4.5 (40)

3

Cu 10-14 AWG; Al 10-12 AWG

4.0 (35)

JM60200-1CR

110-

1

250 MCM-1 AWG

3/0-1 AWG

42 (375)

JM60200-2CR CVR-J-60200

CVRI-J-60200

200

2

2-6 AWG; (2) Cu 2-6 AWG

2-6 AWG

31 (275)

LPJ_SP

JM60200-3CR

600

PJ_SPI**

JM60400-1CR

1

600kcmil

57 (500)

JKS

JM60400-2CR CVR-J-60400

CVRI-J-60400

225-

2

500kcmil-4 AWG

N/A

51 (450)

DFJ

JM60400-3CR

400

3

(2) Cu 3/0 - 4 AWG

57 (500)

(2) Al 3/0 - 4 AWG

34 (300)

JM60600-1CR

450-

1

JM60600-2CR CVR-J-60600

CVRI-J-60600

600

2           

(2) 500kcmil-4 AWG

N/A

51 (450)

JM60600-3CR

3

*Covers sold serarately. Blown fuse indication requires 90 volts minimum and closed circuit to operate.
**With 

easy

ID™ blown fuse indication.                    ***Ratings for copper and aluminum wire except where otherwise noted.

250V Class R & H(K)

600V Class R & H(K)

Class J

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

291

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

250V Class R & H(K) Dimensional Specifications

Dimensions - mm (in)

70- 100A

110- 200A

225- 400A

450- 600A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For engineering drawings, go to www.cooperbussmann.com/KnifebladeFuseBlocks

292

Fuse Holders and Blocks

600V Class R & H(K) Dimensional Specifications

Dimensions - mm (in)

70- 100A

110- 200A

225- 400A

450- 600A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For engineering drawings, go to www.cooperbussmann.com/KnifebladeFuseBlocks

293

Fuse Holders and Blocks

Class J Dimensional Specifications

Dimensions - mm (in)

Fuse Holder

s

& Blocks

70- 100A

110- 200A

225- 400A

450- 600A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For engineering drawings, go to www.cooperbussmann.com/KnifebladeFuseBlocks

294

Fuse Holders and Blocks

Class H(K) and R Fuse Blocks – 250V

Data Sheet: H250 Series, 1112; R250 Series, 1110

H250 & R250 Series

Specifications

Descriptions:
H250 Series:

1-, 2- and 3-pole fuse

blocks for use with Class
H fuses.

R250 Series:

1-, 2- and 3-pole fuse

blocks for use with Class
R fuses (Bussmann LPN-
RK and FRN-R and KTN-R fuses).

Dimensions:

See Dimensions illustrations.

Ratings:

Volts: — 250Vac/dc (H250 & R250 Series)

Amps: — 

1

10

-100A

SCCR: — H250 Series; 10kA RMS Sym.

— R250 Series; 200kA RMS Sym.

Agency Information:

CE, UL Listed UL 4248, Guide IZLT,

File E14853; CSA Certified, Class 6225-01, File 47235.

Flammability Rating:

UL 94V0.

Features and Benefits

• H250 fuse blocks provide one, two and three pole housing  

for Class H, K and R fuses at 250Vac.

• H250 fuse blocks are listed with a Short-Circuit Current  

Rating of 10kA RMS Sym.

• R250 fuse blocks provide 1-, 2- and 3-pole housing for Class

R fuses at 250Vac.

• R250 fuse blocks are listed with a Short-Circuit Current 

Rating of 200kA RMS Sym.

Typical Applications

• 250Vac/dc or less Control Systems
• 250Vac/dc or less Industrial Control
• 250Vac/dc or less Industrial Control Circuits

Recommended DIN-Rail adapters for the 

1

10

-30A series

• see page 509.

Class H Fuseblocks (250V) Catalog Data (for NON and REN Fuses)

Terminal Type (Suffix No.)

Screw

Box Lug w/

1

10

1

H25030-1

S            SR

P                    PR

C  

CR

Q

1

C, CR #2-14 Cu, #2-12 Al

to

2

H25030-2

S            SR

P                    PR

C               CR

2

P, PR #10-18 Cu Only

30

3

H25030-3

S            SR

P                    PR

C               CR

3

Q N/A

S, SR #10-18 Cu Only

31

1

H25060-1

C   

CR

CO

4

C, CR #2-14 Cu, #2-8 Al 

to

2

H25060-2

—            —

—                   —

C   

CR

CO

5

CO #2-14 Cu Only

60

3

H25060-3

—            —

—                   —

C   

CR

CO

6

61

1

H25100-1

—           SR 

—                   —

—              CR

7

to

2

H25100-2

—           SR 

—                   —

—  

CR

8

CR #1/0-8 Cu/Al

100

3

H25100-3

—           SR 

—                   —

—              CR

9

SR #8W/ Ring Terminal

Amps

Catalog

Number

Pressure

Plate

Pressure Plate

& Clip with

Reinforced Spring

Copper

Only

Wire

Range

0.25˝

Quick

Connect

Clip with 

Reinforced

Spring

Clip with 

Reinforced

Spring

Figure

Number

Poles

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

295

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Class H(K) and R Fuse Blocks – 250V

Data Sheet: H250 Series, 1112; R250 Series, 1110

1.41"

0.22"

1.09"

3.03"

0.5"

0.17"

0.75"

0.25"

1.25"

0.95"

0.22" DIAMETER

0.41"

2.05"

2 SPACES AT

0.95" - 1.91"

2.5"

3"

0.55"

1.27"

1.52"

0.55"

Dimensions – in
250V 

1

10

to 30A

FIGURE 1.  

FIGURE 2.

FIGURE 3.

4.25

0.27

1.73

1.5

0.5

2.81

0.5

1.31

0.5

1.31

4.125

G

1.5

0.5

1.31

0.5

1.25

0.22 x 0.41

0.22 x 0.41

0.22 x 0.41

250V, 31A to 60A

FIGURE 4.

FIGURE 5.

FIGURE 6.

Class R Fuseblocks (250V) Catalog Data (for LPN-RK, FRN-R and KTN-R Fuses)

Terminal Type (Suffix No.)

Screw w/

Box Lug w/

0.25”

Catalog

Pres.

Clip

Quick-

Fig.

Wire

Number

Plate

Cu Only

Connect

No.

Range

1

10

1

R25030-1

SR

PR

CR

COR

QR*

1

COR  #6-14  Cu Only

to

2

R25030-2

SR

PR

CR

COR

2

CR #2-14 Cu, #2-12 Al

30

3

R25030-3

SR

PR

CR

COR

3

PR #10-18 Cu Only 

QR N/A 

SR #10-18 Cu Only

31

1

R25060-1

CR

4

to

2

R25060-2

CR

5

CR #2-14 Cu, #2-8 Al

60

3

R25060-3

CR

6

61

1

R25100-1

CR

7

to

2

R25100-2

CR

8

CR 1/0-8 Cu/Al

100

3

R25100-3

CR

9

Poles

Amps

250V, 61A to 100A

FIGURE 7.

FIGURE 8.

FIGURE 9.

7.36"

0.25"

2.06"

1.81"

0.62"

3.38"

0.59"

0.62"

4.94"

2.38"

2.125"

0.62"

0.28" DIA. x
0.5" C'BORE

0.59"

1.56"

1.56"

1.56"

3.125"

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

296

Fuse Holders and Blocks

Class H(K) and R Fuse Blocks – 600V

Data Sheet: H600 Series, 1113; R600 Series, 1111

H60030-2PR

H60030-3C

H600 & R600 Series

Specifications
Descriptions:
H600 Series:

fuse blocks for use with 1-, 2- and 3-pole

Class H fuses.

R600 Series:

fuse blocks for use with 1-, 2- and 3-pole

Class R fuses (Bussmann LPS-RK, FRS-R, PVS-R and 

KTS-R fuses).

Dimensions:

See Dimensions illustrations.

Ratings:

Volts: — 600Vac/dc (H600 & R600 Series)

Amps: — 

1

10

-100A

SCCR: — H600 Series; 10kA RMS Sym.

— R600 Series; 200kA RMS Sym.

Agency Information:

CE, UL Listed UL 4248, Guide IZLT,

File E14853; CSA Certified, Class 6225-01, File 47235.

Flammability Rating:

UL 94V0.

Features and Benefits

• H600 fuse blocks provide one-, two- and three-pole housing 

for Class H, K and R fuses at 600Vac.

• H600 fuse blocks are listed with a Short-Circuit Current  

Rating of 10kA RMS Sym.

• R600 fuse blocks provide one-, two- and three-pole housing  

for Class R fuses at 600Vac.

• R600 fuse blocks are listed with a Short-Circuit Current 

Rating of 200kA RMS Sym.

Typical Applications

• 600Vac/dc or less Control Systems
• 600Vac/dc or less Industrial Control
• 600Vac/dc or less Individual Control Circuits

Class H Fuseblocks (600V) Catalog Data (for NOS and RES Fuses)

Terminal Type (Suffix No.)

Screw

Box Lug w/

1

10

1

H60030-1

S            SR

P                    PR

C  

CR

1

C, CR #2-14 Cu, #2-12 Al

to

2

H60030-2

S            SR

P                    PR

C               CR

2

P, PR, S, SR #10-18 Cu Only

30

3

H60030-3

S            SR

P                    PR

C               CR

3

31

1

H60060-1

C   

CR

to

2

H60060-2

—            —

—                   —

C   

CR

5

C, CR #2-14 Cu, #2-8 Al

60

3

H60060-3

—            —

—                   —

C   

CR

6

61

1

H60100-1

—            —  

—                   —

—              CR

7

to

2

H60100-2

—            —  

—                   —

—  

CR

8

CR #1/0-8 Cu/Al

100

3

H60100-3

—            —  

—                   —

—              CR

9

Pressure

Plate

Pressure Plate

& Clip with

Reinforced Spring

Wire

Range

Clip with 

Reinforced

Spring

Figure

Number

Amps

Catalog

Number

Clip with 

Reinforced

Spring

Poles

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

297

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Class H(K) and R Fuse Blocks – 600V

Data Sheet: H600 Series, 1113; R600 Series, 1111

Class R Fuseblocks (600V) Catalog Data (for LPS-RK, FRS-R, PVS-R and KTS-R Fuses)

Terminal Type (Suffix No.)

Screw w/

Box Lug w/

Catalog

Pres.

Clip

Fig.

Wire

Number

Plate

Cu Only

No.

Range

1

10

1

R60030-1

SR

PR

CR

1

COR #6-14 Cu Only

to

2

R60030-2

SR

PR

CR

COR

2

CR #2-14 Cu, #2-12 Al

30

3

R60030-3

SR

PR

CR

COR

3

PR, SR #10-18 Cu Only

31

1

R60060-1

CR

4

to

2

R60060-2

CR

5

CR #2-14 Cu, #2-8 Al

60

3

R60060-3

CR

6

61

1

R60100-1

CR

7

to

2

R60100-2

CR

8

CR, 1/0-8 Cu/Al 

100

3

R60100-3

CR

—           

9

6.25

0.26

1.73

1.54

0.62

2.90

0.25

1.56

0.62

1.56

4.25

3.13

1.56

0.62

1.56

0.25

0.28 x 0.5

0.28 x 0.5

0.28 x 0.5

7.36"

0.25"

2.06"

1.81"

0.62"

3.38"

0.59"

0.62"

4.94"

2.38"

2.125"

0.62"

0.28" DIA. x
0.5" C'BORE

0.59"

1.56"

1.56"

1.56"

3.125"

Dimensionals – in

600V, 

1

10

to 30A 

600V, 31 to 60A

FIGURE 1.

FIGURE 2.

FIGURE 3.

FIGURE 4.

FIGURE 5.

FIGURE 6.

Amps

Poles

0.88

0.88

0.67

1.81

4.03 

2.22 

0.28 x 0.5

0.28 x 0.5

0.88

0.67

1.81

1.81

0.28 x 0.5

5.84 

9.5

0.34

2.38

4.25

2.63

600V, 61 to 100A

FIGURE 7.

FIGURE 8.

FIGURE 9.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

298

Fuse Holders and Blocks

J600 Series

Specifications
Description: 

1-, 2- or 3-pole fuse blocks for use with Class

J fuses (Bussmann LPJ, DFJ and JKS).

Dimensions:

See Dimensions illustrations.

Construction:

Thermoplastic.

Poles:

1 to 3

Ratings:

Volts: — 600Vac/dc

Amps: — 

1

2

-100A

SCCR: — 200kA RMS Sym.

Agency Information:

CE, UL Listed, UL 4248, Guide IZLT,

File E14853, CSA Certified, C22.2 No. 4248, Class 6225-01,
File 47235.

Flammability Rating:

UL 94V0.

Mounting:

Accepts DIN-Rail adapter DRA-1. See page 507.

Class J Fuse Blocks

Data Sheet: 1114

1

2

- 60A 

Dimensions - in (±0.015)

.30"

2.28"

6.28"

.94"

.22"
Dia.

.5"
C'Bore

1.583"

5"

3.14"

1.75"

1.5"

FIGURE 4.                      FIGURE 5.

Catalog Numbers

Pressure

Box

Box Lug w/

Fig.

Wire

Screw†

Plate†

Lug

Retaining Clip

Amps

Poles

No.

Range

J60030-1S*

J60030-1P

J60030-1C

J60030-1CR††

1

1

C, CR #2-14 Cu, #2-8 Al

J60030-2S*

J60030-2P

J60030-2C

J60030-2CR††

1

2

-30

2

2

COR #2-14 Cu Only

J60030-3S*

J60030-3P

J60030-3C

J60030-3CR††

3

3

P, PR, S, SR #10-14 Cu Only

J60060-1C

J60060-1CR††

1

1

C, CR, #2-14 Cu/Al

J60060-2C

J60060-2CR††

31-60

2

2

COR #4-14 Cu Only

J60060-3C

J60060-3CR††

3

3

J60100-1CR

61-100

1

4

COR 1/0-8 Cu Only

J60100-3CR††

3

5

CR, CRQ 1/0-8 Cu/Al

†Clip reinforcing springs are standard on fuse blocks rated 100A and above. Available on 30A and 60A blocks by adding the  letter “R” to the end of the part

number.

††Copper only connections available by changing “CR” suffix to “COR”.
*No UL, No CSA Certification

Features and Benefits

• J600 fuse blocks provide one-, two- and three-pole housing 

for Class J fuses at 600Vac.

• J600 fuse blocks are listed with a Short-Circuit Current 

Rating of 200kA RMS Sym.

Typical Applications

• 600Vac/dc or less Control Systems
• 600Vac/dc or less Industrial Control
• 600Vac/dc or less Individual Control Circuits

Catalog Numbers

61-100A

2.415"

.750

1.702

2.250

3.202

.750

4.702

2.250

C

L

L

1.500

4.005

C

FIGURE 1.             FIGURE 2.                                     FIGURE 3.

61-100

31-60

1

2

-30

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

299

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Class J Fuse Blocks

JP Series

Specifications
Description:

Pyramid style 3-pole fuse block for use with

Class J fuses  (Bussmann LPJ, DFJ, JKS).

Dimensions: 

See Dimensions illustrations.

Ratings:

Volts: — 600Vac/dc

Amps: — 0-30A

SCCR: — 200kA RMS Sym.

Agency Information:

CE, UL Listed, UL 4248, Guide IZLT,

File E14853, CSA Certified, C22.2 No. 39, Class 4225-04,
File 47235.

Flammability Rating:

UL 94V0.

Mounting:

Panel or 35mm DIN-Rail mount. 

To order DIN-Rail: Part# NDNA 100 (1 meter) or NDNA 200 
(2 meter).

Catalog Numbers

Mounting

With

Screws

DIN

with

Box

Catalog

Rail Pressure

Copper

Numbers

Panel

Adapter* Plate

Aluminum

Only

Wire Range

JP60030-3PR

X

X

#10-14 Cu Only

JP60030-3CR

X

X

#2-14 Cu/Al

JP60030-3COR

X

X

#2-14 Cu Only

JP60030-3PRA

X

X

#10-14 Cu Only

JP60030-3CRA

X

X

#2-14 Cu/Al

JP60030-3CORA

X

X

#2-14 Cu Only

*Adapter only for DIN-Rail - Cat No. JPA-3.

3.29"

(83.6mm)

END STOPS - PREVENT BLOCK MOVEMENT WHEN CHANGING FUSES 

DIN-RAIL MOUNTING SCREW 8" 

(203.2mm)

 APART

4.00" MAX.

(101.6mm)

1.19"

(30.2mm)

3.75" (0.02)

(95.3mm (0.50)

1.88"

(47.6mm)

2.38"

(60.4mm)

2.78"

(70.6mm)

3.06"

(77.8mm)

3.13"

(79.5mm)

ADAPTOR 
FOR 35mm
SYMMETRICAL 
DIN-RAIL
MOUNTING 

Dimensions - in ± 0.015” (± 0.40mm)

Data Sheet:1108

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

300

Fuse Holders and Blocks

Class T Fuse Blocks – 300V

Data Sheet:  1115

T30030-S
SECTION X-X

0.91"

1.63"

0.72"

0.16"

Z

X

Full
Radius

Z

X

0.44"

0.20"

C

B

1.20"

A

0.69"

2.5"

2.75"

T30060-C
SECTION Z-Z

0.91"

1.63"

0.72"

0.16"

Dimensions - in

Figure 1. 

1

2

-60A

T300

Specifications
Description:

T300 (300V) fuse blocks for use with Class T

fuses  (Bussmann JJN).

Dimensions: 

See Dimensions illustrations.

Poles:

1 to 4

Ratings:

Volts: — 300Vac/dc

Amps: — 

1

2

- 600A

SCCR:— 200kA RMS Sym.

Agency Information:

CE, UL Listed UL 4248, Guide IZLT,

File E14853, CSA Certified, Class 6225-01, File 47235.

Flammability Rating:

UL 94V0.

Features and Benefits

• Provide 1-, 2- and 3-pole housing for 300Vac Class T fuses.
• Short-Circuit Current Rating of 200kA RMS Sym.
• Class T fuse blocks have a small foot print, providing 

substantial space savings in equipment

Typical Applications

• 300Vac/dc or less Control Systems

• 300Vac/dc or less Individual Control Circuits

Catalog Numbers

T30100-1CR

T30030-2CR

T30600-1C

Catalog

Dimensions - in

Number

A

B

C

T30030-2

2.41

1.03

T30060-2

2.41

1.03

T30030-3

3.44

1.03

2.06

T30060-3

3.44

1.03

2.06

T30030-4

4.47

2.06

3.09

T30060-4

4.47

2.06

3.09

Catalog Numbers

Fig.

Screw

Box Lug

Amps

Poles No.

Wire Range

T30030-2SR T30030-2CR

1/2-30

2

1

SR #10-18 Cu

T30030-3SR T30030-3CR

3

CR #6-14 Cu/Al

T30030-4SR T30030-4CR

4

T30060-2SR T30060-2CR

31-60

2

1

CR #2-14 Cu/Al

T30060-3SR T30060-3CR

3

SR #10-18 Cu Only

T30060-4SR T30060-4CR

4

T30100-1CR

61-100

1

2

T30100-2CR

2

1/0-8  Cu/Al

T30100-3CR

3

T30200-1C

101-200

1

3

250kcmil-6 Cu/Al

T30200-3C

3

4

T30400-1C

201-400

1

5

600kcmil-2/0 Cu/Al

T30600-1C

401-600

1

(2) 600kcmil-4/0 Cu/Al

1

2

-30

1

2

31-60

61-100

101-200

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

301

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Class T Fuse Blocks – 300V

Data Sheet: 1115

Z

Z

0.52" C'BORE
0.55" DEEP

0.22" DIA.

X

X

2.39"

2.25"

REF.

4.78"

2.06"

1.69" 

(1 POLE)

3.09" 

(2 POLE)

4.5"

 (3 POLE)

1.41" 

(2 POLE)

2.81"

 (3 POLE)

0.84"

0.38"

0.75"

0.625" C'BORE 0.438" DEEP

0.282" DIAMETER THRU HOLE

.996"

A

A

2.75"

1.695"

       4.87" 

 

0.625"

2.375"

 4.46"

Figure 2. 61 to 100A

3"

6"

0.28" DIAMETER

0.63" C'BORE 0.5" DEEP

1.125"

2.56"

1.94"

0.81"

3.06"

1.69"

0.05"

1.25"

2.25"

Figure 3.  101 to 200A

Figure 4.  200A

0.63" C'BORE 0.5" DEEP

6"

0.28" DIAMETER

1.125"

2.25"

0.63"

3"

1.25"

1.84"

0.81"

2.38"

3.06"

Figure 5.  201 to 400A

3.44"

0.75"

3"

2.03"

3"

2"

1.5"

5.75"

2.88"

0.33" DIAMETER

0.75" C'BORE 0.5" DEEP

Figure 6.  401 to 600A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

302

Fuse Holders and Blocks

Class T Fuse Blocks – 600V

Data Sheet: 1116

Figure 1. 

1

2

to 30A

3.19"

1.44"

1.563"

0.33"

1.42"

0.5"

1.44"

0.55"

0.33" 0.55"

2.59"

1.16"

0.33"

0.55"

3.75"

2.31"

0.33"

0.22" DIAMETER

0.5" C'BORE

2.94"

1.75"

1.63"

1.47"

0.5"

1.81"

0.59"

0.63" 0.59"

3.34"

1.53"

0.63"

0.59"

4.86"

3.06"

0.63"

0.22" DIAMETER

0.5" C'BORE

Figure 2.  31 to 60A

T600

Specifications
Description:

T600 (600V) fuse blocks for use with Class T

fuses  (Bussmann JJS).

Dimensions: 

See Dimensions illustrations.

Poles:

1 to 3

Ratings:

Volts: — 600Vac/dc

Amps: — 

1

2

- 600A

SCCR:— 200kA RMS Sym.

Agency Information:

CE, UL Listed UL 4248, Guide IZLT,

File E14853, CSA Certified, Class 6225-01, File 47235.

Flammability Rating:

UL 94V0.

Features and Benefits

• Provide 1-, 2- and 3-pole housing for 600Vac Class T fuses.
• Short-Circuit Current Rating of 200kA RMS Sym.
• Class T fuse blocks have a small foot print, providing 

substantial space savings in equipment

Typical Applications

• 600Vac/dc or less Control Systems

• 600Vac/dc or less Individual Control Circuits

T30030-2CR

T60600-1C

Fig.

Screw

Box Lug

Amps

Poles No.

Wire Range

T60030-1SR

T60030-1CR

1

1

SR #10-18 Cu

T60030-2SR

T60030-2CR

1/2-30

2

T60030-3SR

T60030-3CR

3

CR #2-14 Cu/Al

T60060-1SR

T60060-1CR

1

2

CR #2-14 Cu/Al

T60060-2SR

T60060-2CR

31-60

2

T60060-3SR

T60060-3CR

3

SR #10-18 Cu Only

T60100-1C

1

3

T60100-2C

61-100

2

2/0-14 Cu/Al

T60100-3C

3

T60200-1C

101-200

1

4

250kcmil-6 Cu/Al

1B0089*

3

T60400-1C

201-400

1

5

600kcmil-2/0 Cu/Al

T60600-1C

401-600

1

6

(2) 600kcmil-4/0 Cu/Al

* UL Listed, Guide IZLT, File E14853, CSA Certified Class 6225-01, File 21455M18

Catalog Numbers

1

2

-30

1

2

3

4

31-60

61-100

101-200

Dimensions - in

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

303

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Class T Fuse Blocks – 600V

Data Sheet: 1116

Figure 5.  201 to 400A

0.63" C'BORE 0.5" DEEP

6"

0.28" DIAMETER

1.125"

2.25"

0.63"

3"

1.25"

2.72"

0.81"

2.38"

3.06"

Figure 4.  101 to 200A

3"

6"

0.28" DIAMETER

0.63" C'BORE 0.5" DEEP

1.125"

2.56"

1.94"

0.81"

3.06"

2.5"

0.05"

1.25"

2.25"

Figure 3.  61 to 100A

Z

Z

0.52" C'BORE
0.55" DEEP

0.22" DIA.

X

X

2.39"

1.69" 

(1 POLE)

3.09" 

(2 POLE)

4.5"

 (3 POLE)

1.41" 

(2 POLE)

2.81"

 (3 POLE)

0.84"

0.38"

SECTION Z-Z

0.78"

2.34"
REF.

0.75"

Figure 6.  401 to 600A

3.44"

0.75"

3"

2.95"

3"

2"

1.5"

6.75"

3.38"

0.33" DIAMETER

0.75" C'BORE 0.5" DEEP

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

304

Fuse Holders and Blocks

BCA Series - Class CC fuses
BMA Series - 

13

32

" X 1 

1

2

" fuses

Specifications
Description:

1-, 2 and 3-pole fuse

blocks for use with Class CC fuses
(BCA Series use Bussmann 
LP-CC, KTK-R, and FNQ-R), or with
standard 

13

32

" x 1 

1

2

" fuses (BMA Series

use Bussmann KTK, FNQ, PVN, FNM,
BAF, PV and AGU) Both Series use an
"adder block" to form multi-pole seg-
mented blocks to achieve the desired
number of poles.

Dimensions:

See Dimensions 

illustration.

Poles:

1 to 3.

Wire Range:

#10-#18 Cu only.

Terminals:

Screw/quick connect*

or pressure plate/quick connect*.

Ratings:

Volts: — 600Vac/dc

Amps: — 

1

10

-30A

SCCR: — BCA Series: 

200kA RMS Sym.
BMA Series:
10kA RMS Sym.

Agency Information:

BCA Series:

CE, UL Listed, UL

4248, Guide IZLT, File E14853.
CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235.

BMA Series:

CE, UL Recognized, UL 4248, Guide IZLT2,

File E14853. CSA Certified, C22.2 No. 4248, Class 6225-01,
File 47235.

Flammability Rating:

UL 94V0

*Quick connect rated for 20A maximum.

Catalog Numbers

BCA Series

Catalog Numbers

Poles

Terminal Type

BCA603ASQ

Adder Block

Screw w/ quick connect

BCA6031SQ

1

Screw w/ quick connect

BCA6032SQ

2

Screw w/ quick connect

BCA6033SQ

3

Screw w/ quick connect

BCA603APQ

Adder Block

Pressure plate w/ quick connect

BCA6031PQ

1

Pressure plate w/ quick connect

BCA6032PQ

2

Pressure plate w/ quick connect

BCA6033PQ

3

Pressure plate w/ quick connect

Add-a-pole Fuse Blocks

Data Sheets: BCA Series 1154, BMA Series 1155

Dimensions in ± 0.015" (0.38mm)

Adder Block

1-Pole

2-Pole

3-Pole

BMA Series

Catalog Numbers

Poles

Terminal Type

BMA603ASQ

Adder Block

Screw w/ quick connect

BMA6031SQ

1

Screw w/ quick connect

BMA6032SQ

2

Screw w/ quick connect

BMA6033SQ

3

Screw w/ quick connect

BMA603APQ

Adder Block

Pressure plate w/ quick connect

BMA6031PQ

1

Pressure plate w/ quick connect

BMA6032PQ

2

Pressure plate w/ quick connect

BMA6033PQ

3

Pressure plate w/ quick connect

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

305

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Class CC, Type M and Class G Fuse Blocks

Data Sheet: 1106

Data Sheet:  1104

Data Sheet: 1105

Specifications

Description:

Class CC fuse blocks for

use with Class CC fuses ( Bussmann 
LP-CC, KTK-R, and FNQ-R).

Dimensions:

See Data Sheet 1105 

Poles:

1 to 3

Ratings:

Volts: — 600V

Amps: — 

1

10

-30A

SCCR:— 200kA RMS Sym.

Agency Information:

CE, UL Listed

(Guide IZLT, File E14853), CSA (Class
6225-01, File 47235)

Flammability Rating:

UL 94V0

DIN-Rail Adapters:

See page 413 for

DRA-1 & DRA-2

Catalog Numbers

Terminal Type

Screw

Pressure

with

Plate w/

Quick

Pressure

Quick

Box

Screw

Connect*

Plate

Connect*

Lug

Poles

BC6031S

BC6031SQ

BC6031P

BC6031PQ

BC6031B

1

BC6032S

BC6032SQ

BC6032P

BC6032PQ

BC6032B

2

BC6033S

BC6033SQ

BC6033P

BC6033PQ       BC6033B

3

BCCM Series

Description:

3-pole fuse block for use

with (2) Class CC fuses and (1) 

13

32

” x 1

1

2

fuse

Catalog Numbers

Catalog

Terminal

Numbers

Type

BCCM6033SQ

Screw with Quick-Connect*

BCCM6033PQ

Pressure Plate w/Quick-Connect*

*Quick-connect terminal rated for 20A max.

Specifications

Description: 

Supplementary fuse

blocks for use with any 

13

32

” x 1

1

2

” fuses

(Bussmann KTK, PVM, FNQ, FNM,
BAF, PV, and AGU).

Dimensions:

See Data Sheet 1104 

Poles:

1 to 3

DIN-Rail Adapters:

See page 413

for DRA-1 & DRA-2

Ratings:

Volts: — 600Vac/dc

Amps: — 

1

10

-30A

SCCR:— 10kA RMS Sym.

Agency Information:

CE, UL

Recognized (Guide IZLT2, File
E14853), CSA (Class 6225-01, File
47235).

Flammability Rating:

UL 94V0.

Catalog Numbers

Terminal Type

Screw

Pressure

with

Plate w/

Quick

Quick

Box

Connect*

Connect*

Lug

Poles

BM6031SQ

BM6031PQ

BM6031B

1

BM6032SQ

BM6032PQ

BM6032B

2

BM6033SQ

BM6033PQ

BM6033B

3

Specifications

Description: 

Class G fuse blocks for use

with Class G fuses (Bussmann SC).

Dimensions:

See Data Sheet 1106 

Poles:

1 to 3

Ratings:

Volts: — 600Vac/dc (0-20A)

— 480Vac/dc (25-60A)

Amps: — 1-60A (See Catalog Numbers

table)

SCCR: — 100kA RMS Sym.

Agency Information:

CE, UL Listed 

35-60A (Guide IZLT, File E14853), UL
Recognized 1-30A, (Guide IZLT2, File
E14853), CSA (Class 6225-01, File 47235).

DIN-Rail Adapters:

See page 413 for

DRA-1 & DRA-2.

Catalog Numbers

Terminal Type

Screw

Pressure

with

Plate w/

Box Lug

Quick

Quick

Box

w/retaining

Connect*

Connect*

Lug

clip

Amps

Poles

BG3011SQ BG3011PQ

BG3011B

1

1

BG3012SQ BG3012PQ BG3012B

to

2

BG3013SQ BG3013PQ BG3013B

15

3

BG3021SQ BG3021PQ BG3021B

20

1

BG3022SQ BG3022PQ BG3022B

2

BG3023SQ BG3023PQ BG3023B

3

BG3031S

BG3031P

BG3031B

25

1

BG3032S

BG3032P

BG3032B

to

2

BG3033S

BG3033P

BG3033B

30

3

G30060-1CR

35

1

G30060-2CR

to

2

G30060-3C G30060-3CR

60

3

BC Series

BM Series Type M

BG & G Series

1-15

20

25-30

35-60

Recommended Cover Puller

• PF1-WH (White)
• PF1-BK (Black)

Recommended Cover Puller

• PF1-WH (White)
• PF1-BK (Black)

Recommended Cover Puller

• PF1-WH (White)
• PF1-BK (Black)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

306

Fuse Holders and Blocks

Modular Fuse Blocks

Specifications

Description:

For use with Bussmann high speed fuses.

Ratings:

SCCR: — 200kA RMS Sym. or fuse IR, whichever 

is lower.

Agency Information:

CE, UL Recognized, Guide EZLT2,

File No. E14853 up to 700V, CSA Certified, Class 6225-01,
File No. 47235 up to 700V.

BH Series Features and Benefits

• BH fuse blocks provide a wide range of mounting

configurations for Bussmann high speed fuses.

• BH fuse blocks have a Short-Circuit Current Rating of any   

installed fuse up to 200kA RMS Sym.

Typical Applications

• Solid State Control Circuits
• VFDs
• UPS Systems

Catalog Numbers

BH-0001

BH-0122

BH-2001

BH-3004

BH-0002

BH-1001

BH-2002

BH-3033

BH-0003

BH-1002

BH-2003

BH-3144

BH-0111

BH-1003

BH-2031

BH-3145

BH-0112

BH-1131

BH-2032

BH-0113

BH-1132

BH-2033

BH-0121

BH-1133

BH-3003

Data Sheet: (BH-0) 1200; (BH-1) 1201; (BH-2) 1202;
(BH-3) 1203

Refer to the data sheet numbers below for the catalog code
description information.

Figure 1

Figure 2

BH Series

Modular Type Fuse blocks for Class H &
J Fuses

Specifications

Description:

3-Pole only, modular type fuse blocks for

Class H & J fuses with  standard reinforced retaining clips.

Ratings:

Volts: — 250V (0-60A See Catalog Numbers table)

— 600V (35-60A See Catalog Numbers table)

Amps: — 0-60A @ 250Vac/dc (See Catalog Numbers table)

— 35-60A@600V (See Catalog Numbers table)

SCCR: — Class J 200kA, Class H 10kA

Agency Information:

CE, UL Recognized, Guide IZLT2,

File E14853, CSA Certified, Class 6225-01, File 47235.

Class H & J Features and Benefits

• H & J modular fuse blocks provide three pole 30 and 60  

amp ratings for specific client requirements for separate line 
and load fuse clip configurations.

Typical Applications

• Up to 60A, space confined, control circuits

Catalog Numbers
Fuse

Fig.

Screw

Pressure Plate Class

Volts

Amps

No.

11241-3SR*

11241-3PR*

H

250

60

1

11242-3SR

11242-3PR

2

11241-3SR

11241-3PR

600

35

1

11242-3SR** 11242-3PR**

2

11239-3SR

11239-3PR

60

1

11240-3SR** 11240-3PR**

2

11241-3SR

11241-3PR

J

600

35

1

11239-3SR*

11239-3PR*

60

1

Note: Order two blocks per fuse (matched or mixed.)

*11239 and 11241 have wire terminals and mounting holes located under fuse. (Figure 1)
**11240 and 11242 have wire terminals and mounting holes located at end of fuse. (Figure 2)

H

J

250

60

60

35

600

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

307

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

SOU, SRU, SSN, SSU, SOW, SRW, SSW,
SOX, SRX, SSX, SOY, SRY, SSY, SSY-RL, 
SSY-L, STY, SCY & SOY-B

Specifications

Description:

Box covers for standard electrical boxes that

provide fused outlet, fused switch or circuit fuse protection.

Ratings:

Volts: — 125V/250V (See Catalog Numbers table)

Amps: — 0-15A (See Catalog Numbers table)

Agency Information:

CE, See Catalog Numbers table.

Features/Benefits

• Bussmann Box Cover Units provide a low-cost method of

controlling and protecting small motors when used with
Bussmann Type T, Fusetron

, dual-element fuses.

• Provide low-cost supplementary protection and 

disconnection of 125V or less, single phase circuits.

Typical Applications

• Fractional Horsepower, 125 Volt Single-Phase Motor Circuits
• General 125 Volt Supplemental Circuits

Box Cover Units for Plug Fuses

Data Sheet: 1129

Catalog Numbers

Receptacle

Motor

Agency4

Catalog

Fuse holder3

Outlet to Load

Switch

Switch

Size

Listing/

Numbers

Type Box

Single Double

125V

250V

Control1

Light2

(Max)

General Data

Certification

SOU

X

3

4

hp

125V, 15A

UL, CSA

SRU

2

1

4

" Handy

X

X

1

2

hp

125V, 15A

UL

SSU

X

X

1

2

hp

125Vac, (do not use on dc), 15A

UL, CSA

SOW

X

3

4

hp

125V, 15A

UL, CSA

SRW

2

3

4

" Switch

X

X

1

2

hp

125V, 15A

UL

SSW

X

X

1

2

HP

125Vac, (do not use on dc), 15A

UL, CSA

SOX

X

3

4

hp

125V, 15A

UL, CSA

SRX

4" Octagon

X

X

1

2

hp

125V, 15A

UL

SSX

X

X

1

2

hp

125Vac, (do not use on dc), 15A

UL, CSA

SOY

X

3

4

hp

125V, 15A

UL, CSA

SRY

X

X

1

2

hp

125V, 15A

UL

SSY

X

X

1

2

hp

125Vac, (do not use on dc), 15A

UL, CSA

SSY-RL

4" Square

X

X

X

X

1

2

hp

125Vac, (do not use on dc), 15A

STY3

X

X

1

2

hp

125Vac, (do not use on dc), 15A

UL

SCY

X

X(2)

1

2

hp (2)

125Vac, (do not use on dc),
can protect two motors, 15A

UL

SOY-B

X

3

4

hp

125V, protects two motors, 15A

UL

SSN

Single Gang

X

X

X

1

2

hp

Weatherproof model, 15A

UL

1 Switch turns power to fused load OFF or ON.
2 Switch light indicates power to load (dark when switch OFF or fuse open).
3 Double pole switch opens both sides of circuit. Can be used for two separate motors with common switch or a single motor (

3

4

Hp, 250Vac max.).

4 UL Guide JAMZ, File IE6491; CSA Class 6225-01, File 47235.

2

1

4

" Handy

2

3

4

" Switch

4" Octagon

4" Square

Y

T

S

SSU

SSN

SRU

SOU

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

308

Fuse Holders and Blocks

Specifications

Description: 

Water-resistant in-line

fuse holder for 

1

4

" x 1

1

4

" fuses.

Dimensions: 

See Dimensions 

illustration.

Construction:

Thermoplastic rubber

body with tin-plated, copper contacts.

Ratings:

Volts: — 32V

Amps: — 30A max

Catalog Numbers

Catalog
Numbers

Description

HFB*

Standard Pack (10-in)

BK/HFB

Bulk Pack (100-in)

BK/1A2294

HFB Replacement Contact Clip

1A2294-01

HFB-10** Replacement Contact Clip

*HFB accepts #12 to #18 wire leads (not provided). See
Data Sheet for recommended crimp tools.
**HFB-10 accepts #10 wire leads (not provided). See Data
Sheet for recommended crimp tools.

Features/Benefits

• Simple assembly with one-piece 

thermoplastic (important information  
molded into body)

• High visibility yellow color for easy 

identification in dark or hard-to-access 
locations

• Ideal for shock and vibration 

environments; withstands many 
organic solvents; temperature range -
40/+150°C

Typical Applications

• Supplemental, Low Voltage, Low 

Amperage Control Circuits

Dimensions - in (mm)

In-line Fuse Holders for 

1

4

" x 

7

8

" to 1

1

4

" Fuses

0.75"

(19.1mm)

3"

(76.2mm)

Data Sheet: 2102

Data Sheet: 2111

Data Sheet: 2103

Specifications

Description: 

Universal in-line fuse

holder for 

1

4

" x 

7

8

" to 1 

1

4

" fuses.

Dimensions: 

See Dimensions 

illustration.

Construction:

8" (203mm) #14 lead

wires.

Ratings:

Volts: — 32V

Amps: — 15A max

Features and Benefits

• HRK Universal in-line fuse holder for

1

4

" x 

7

8

", 1" and 1

1

4

" fuses with #14

lead wires.

• RoHS compliant 

Typical Applications

• Supplemental, Low Voltage, Low  

Amperage Control Circuits

Catalog Number

Catalog

Amp

Number

Rating Volts

Fuse Description

HRK-R*

15

32

1

4

" diameter fuses of

different lengths.

*Three springs furnished with fuse holder to accommodate
different length 

1

4

" fuses.

Dimensions - in (mm)

Specifications

Description: 

Universal in-line fuse

holder for 

1

4

" x 

7

8

", 1" and 1

1

4

" fuses.

Dimensions: 

See Dimensions 

illustration.

Construction:

Nylon body with tin-

plated, copper contacts.

Ratings:

Volts: — 32V

Amps: — 30A max

Flammability Rating:

UL 94V2.

Pull Force:

5lbs minimum to separate

fuse holder housing with fuse installed.

Features and Benefits

• HHB  Universal in-line fuse holder for

1

4

" x 

7

8

", 1" and 1 

1

4

" fuses.

Typical Applications

• Supplemental, Low Voltage, Low  

Amperage Control Circuits

Catalog Numbers

Holder — without leads* - RoHS compliant

Catalog Numbers

Description

HHB-R

Standard Pack (10-in)

BK/HHB-R

Bulk Pack (100-in)

*Accepts #12 to #16 wire leads (not provided with basic fuse
holder). See Data Sheet for recommended crimp tools.

Holder — with pre-attached #14 Insulated
lead wires - Not RoHS compliant unless
noted

Catalog Numbers

Wire

19" Length

8" Length

Color

BK/HHB-Y419

BK/HHB-Y408

Yellow

BK/HHB-R419

BK/HHB-R408**

Red

BK/HHB-B419

BK/HHB-B408

Black

**RoHS compliant.

Dimensions - in (mm)

Fuse Length

Fuse Holder Length “L”

7

8

" (AGW)

2.100 Max

1" (AGX)

2.250 Max

1

1

4

" (AGC, MDL)

2.420 Max

L

0.53"

(13.5mm)

0.75"

(19.1mm)

2.19"

(55.6mm)

1.56"

(39.7mm)

0.69"

(17.5mm)

0.38"

(9.5mm)

HFB & HFB-10

HHB

HRK

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

309

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

HR and HM Series

Specifications

Description:

In-line

fuse holders for SFE
and 

1

4

" dia. x various

length fuses.

Dimensions: 

See

Dimensions 
illustration.

Ratings:

Volts: — 32V

Amps: — 20A

Features and Benefits

• HR and HM Universal in-line fuse 

holder for SFE and various length 

1

4

diameter fuses with #14 lead wires.

Typical Applications

• Supplemental, Low Voltage, Low  

Amperage Control Circuits

Catalog Numbers

Catalog

Includes

Wire Length

Numbers

Fuse

& Size

HRJ*

SFE-20

HRI

SFE-14

HRH

SFE-9

19” of #14

HRE

SFE-7

1

2

HRG

SFE-6

HRF

SFE-4

HMJ**

SFE-20

HMI

SFE-14

HMH

SFE-9

8” of #14

HME

SFE-7

1

2

HMG

SFE-6

HMF

SFE-4

* Also available as in-line fuse holder only with lead wire
contacts, HRJ-LESS-Fuse.
** Also available as in-line fuse holder only with lead wire
contacts, HMJ-LESS-Fuse.

HHJ-A

For 

1

4

" x 1

1

4

" fuse, no wire or fuse 

included, accepts #18 - #22 wire.

HHJ-B

For 

1

4

" x 1

1

4

" fuse, no wire or fuse 

included, accepts #12 - #16 wire.

HHI-B

For 

1

4

" x 1

1

16

" fuse, no wire or fuse 

included, accepts #12 - #16 wire.

Replacement Contacts

Catalog
Number

Symbol

9838

HHJ-A

9841

HHJ-B

Dimensions - in (mm)

In-line Fuse Holders

0.75"

(19.1mm)

2.19"

(55.6mm)

1.56"

(39.7mm)

0.69"

(17.5mm)

0.38"

(9.5mm)

Data Sheet: 2122

Specifications

Description:

In-line water-resistent

fuse holders for 

1

4

" x 1

1

4

" fuses.

Dimensions: 

See Dimensions 

illustration.

Ratings:

Volts: — 250V

Amps: — 20A

Refer to data sheet for recommend
crimp tools

Catalog Numbers

Catalog
Numbers

Terminals

HFA

Crimp #12 - #16

HFA-HH*

1

4

" Quick Connect

*No UL Recognition.

Specifications

Description: 

In-line fuse holders for 

5 x 15mm or 5 x 20mm fuses.

Dimensions: 

See Dimensions 

illustration.

Construction:

Black thermoplastic

body with brass contacts, wire: 16
AWG, red.

Ratings:

Volts: — 32V

Amps: — 5A (5 x 15mm)

— 10A (5 x 20mm)

Catalog Numbers

Catalog Number

Fuse Size

HHT

5 x 15mm & 5 x 20mm

HFA Series

HHT Series

Data Sheet: 2115

Data Sheet: 2138

Specifications

Description:

Single-pole, non-break-

away, in-line fuse holders for Type SC
fuses, 480V (or less).

Ratings:

Volts: — 600V

Amps: — 0-15A

Fuse Size:

13

32

" x 1.31"

Catalog Number

HEG-AA

Optional Boots:

2A0660   Single Conductor
2A0661   Two Conductor

Specifications

Description:

Single-pole, non-

breakaway, in-line fuse holders for
Type SC fuses (Also fuse types BBS
& KTQ, nominal size 

13

32

" x 1 

3

8

").

Ratings:

Volts: — 600V

Amps: — 0-20A

Agency Information:

CSA - 15A.

Catalog Numbers

HEH-AA, HEH-AD

Optional Boots:

2A0660   Single Conductor
2A0661   Two Conductor

HEG Series

HEH Series

Data Sheet: 2124

Data Sheet: 2124

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

310

Fuse Holders and Blocks

Tron

In-line Fuse Holders

Specifications

Description:

Single-pole,

non-breakaway,

in-line fuse

holders for Type SC-25, &
SC-30 fuses, 

size

13

32

" x 1 

5

8

".

Ratings:

Volts: — 480V

Amps: — 0-30A

Catalog Numbers

HEC-AA, HEC-RW-RLB-R

Optional Boots:

2A0660   Single Conductor
2A0661   Two Conductor

Specifications

Description:

Single-pole,

non-breakaway, in-line fuse
holders for Type SC and Type
HVW fuses, size 

13

32

" x 2 

1

4

".

Ratings:

Volts: — 480V

Amps: — 35-60A Type SC

— 

1

2

-6A Type HVW

Catalog Numbers

HEJ-AA, HEJ-AB, HEJ-AC, HEJ-BB,
HEJ-JJ, HEJ-JK, HEJ-LL, HEJ-LLB,
HEJ-CC, HEJ-DD, HEJ-WW, HEJ-PP,
HEJ-QQ

Optional Boots:

2A0660   Single Conductor
2A0661   Two Conductor

Specifications

Description:

Single-pole

in-line fuse holders for any

13

32

" x 1 

1

2

" fuses (typically

fuse types: BAF, FNM, FNQ,
and KTK 

1

10

- 30A).

Ratings:

Volts: — 600V

Amps: — 0-30A

Catalog Numbers

See Page 311

Optional Boots:

2A0660   Single Conductor

2A0661   Two Conductor

Specifications

Description:

Single-pole

in-line fuse holders for 

13

32

" x 1 

1

2

" fuses with a 

permanently solid neutral
identified by white plastic
coupling nut.

Catalog Numbers

HET-AA, HET-AB, HET-AW, HET-
AW-RLC-A, HET-AW-RLC-B, HET-
AW-RLC-C, HET-AW-RLC-J, HET-
AW-RYC, HET-BB, HET-BW-RLC-B,
HET-BW-RYC, HET-JJ, HET-JK,
HET-JW, HET-JW-RLC-J, HET-JW-
RYC, HET-KK

Specifications

Description:

Waterproof

(IPX7), single-pole Class
CC in-line fuse holders.
Holds Bussmann fuse
types: LP-CC, FNQ-R and
KTK-R.

Ratings:

Volts: — 600V (or less)

Amps: — Up to 30A*

Conductors: Lineside &
Loadside**

#12 to #8 Crimp terminal
#12 to #3 Setscrew terminal

*Amp rating limited by conductor size and fuse sizing 

when used with insulating boots

**See details in non-breakaway and breakaway 

specifications

Data Sheet: 2130

Specifications

Description:

Double-pole in-

line fuse holders for 

13

32

" x 1 

1

2

"

fuses (typically fuse types
BAF, FNM, FNQ, and KTK 

1

10

- 30A).

Ratings:

Volts: — 600V

Amps: — 0-30A

Catalog Numbers

HEX-AA, HEX-AB, HEX-AC, HEX-AD,
HEX-AE, HEX-AW, HEX-AW-DRLC-A,
HEX-AW-DRYC, HEX-AW-RLC-A,
HEX-AW-RYC, HEX-AY, HEX-BB,
HEX-CC, HEX-JJ, HEX-JK, 
HEX-JW-DRYC, HEX-KK

HEB Series

HET Series

HEZ Series

Specifications

Description:

Double-pole

in-line fuse holders for KTK-
R fuses with optional break-
away receptacle, polarized,
and accepting Class CC
branch circuit fuses 
(Bussmann KTK-R, FNQ-R
& LP-CC; 600V or less,
200kA IR).

Ratings:

Volts: — 600V

Amps: — 0-30A

Catalog Numbers

HEY-AA, HEY-AB, HEY-AC, HEY-
AD, HEY-AE, HEY-AL, HEY-AW-
DRLC-A, HEY-AW-DRLC-B, HEY-
AW-DRYC, HEY-BB, HEY-JJ

Data Sheet: 2126

HEY Series

HEX Series

HEC Series

HEJ Series

Data Sheet: 2127

Data Sheet: 2125

Data Sheet: 2126

Data Sheet: 2124

Data Sheet: 2123

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

311

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

For HEB Holders Only

Data Sheet: 2127

Copper        #12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#6

1

Y

Y

Crimp

#10

2

Y

Y

Copper

#6

1

Y

Y

Crimp

#10

2

Y

Y

Copper

#6

1

Y

Y

Crimp

#10

2

Y

Y

Copper

#6

1

Y

Y

Crimp

#10

2

Y

Y

Copper

#4

1

N

Y

Crimp

#8

2

Y

Y

Copper

#2

1

N

Y

Crimp

#6

2

Y

Y

Copper

#20, #18

1

Y

Y

Crimp
Copper

#12 to #3

1

Y

Y

Setscrew
Copper

#12 to #3

1

Y

Y

Setscrew
Copper

#12 to #3

1

Y

Y

Setscrew
Copper

#12 to #3

1

Y

Y

Setscrew
Aluminum

#12 to #2

1

Y

Y

Setscrew
Aluminum

#8

1

N

Y

Crimp

#6

1

Y

N

Aluminum

#6

1

N

Y

Crimp

#4

1

Y

N

Aluminum

#3, #4

1

N

Y

Crimp

#2

1

Y

N

Aluminum

#1, #2

1

N

Y

Crimp
Aluminum

1/0

1

N

Y

Crimp

SolidTerminal

#8 to #12

1

Y

N

for aluminum
connector

#10 to #14

1

N

Y

Copper        #12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#6

1

Y

Y

Crimp

#10

2

Y

Y

Copper #4

1

N

Y

Crimp  

#8

2

Y

Y

Copper

#2

1

N

Y

Crimp

#6

2

Y

Y

Copper

2/0

1

N

Y

Crimp

#3

2

N

Y

Copper

#12 to #3

1

Y

Y

Setscrew 
Copper

#12 to #3

2

Y

Y

Setscrew 
Aluminum

#12 to #2

1

Y

Y

Setscrew 
Aluminum

#12 to #2

2

Y

Y

Setscrew 
Aluminum

#1, #2

1

N

Y

Crimp
Copper

#12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#6

1

Y

Y

Crimp

#10

2

Y

Y

Copper

#4

1

N

Y

Crimp

#8

2

Y

Y

Copper

#2

1

N

Y

Crimp

#6

2

Y

Y

Copper

#4

1

N

Y

Crimp

#8

2

Y

Y

Copper

#2

1

N

Y

Crimp

#6

2

Y

Y

Copper

#12 to #8

1

Y

Y

Crimp

#12

2

Y

Y

Copper

#12 to #3

1

Y

Y

Setscrew
Copper

#12 to #3

2

Y

Y

Setscrew
Aluminum

#12 to #2

1

Y

Y

Setscrew 
Aluminum

#12 to #2

2

Y

Y

Setscrew 
Aluminum

#12 to #2

1

Y

Y

Setscrew 
Aluminum

#8

1

N

Y

Crimp

#6

1

Y

N

Aluminum

#6

1

N

Y

Crimp

#4

1

Y

N

Aluminum

#3, #4

1

N

Y

Crimp

#2

1

Y

N

Aluminum

#1, #2

1

N

Y

Crimp
Aluminum

1/0

1

N

Y

Crimp

SolidTerminal

#8 to #12

1

Y

N

for aluminum
connector

#10 to #14

1

N

Y

Terminal

No. of

Wire Size  Wires per 

Solid  Stranded

Type

Terminal   

Wire

Wire

Loadside Terminal

Directions: To select complete holder P/N, work from left to right starting with loadside terminal options and then lineside terminal options. Then determine breakaway or non-breakaway style.

Terminal

No. of

Wire Size   Wires per 

Solid  Stranded

Type

Terminal   

Wire

Wire

Lineside Terminal

Available P/N’s

Non-Breakaway         Breakaway

P/N

P/N

(Boots not included)

(Boots included)

HEB-AA(1)(2)    HEB-AW-RLC-A(1)(2)

HEB-AB(2)

HEB-AW-RLC-B

HEB-AC(2)

HEB-AW-RLC-C(4)

HEB-AD(2)

N/A

HEB-AE(2)

N/A

HEB-AJ

HEB-AW-RLC-J

HEB-AK

HEB-AW-RYC

HEB-AL

HEB-AW-RLA

HEB-AY

HEB-AW-RYA

HEB-AR

N/A

HEB-BA(2)

HEB-BW-RLC-A

HEB-BB(2)

HEB-BW-RLC-B

HEB-BC(2)

N/A

HEB-BD(2)

N/A

HEB-CC(2)

N/A

HEB-DD(2)

N/A

HEB-ZA

N/A

HEB-JJ

HEB-JW-RLC-J

HEB-JK

HEB-JW-RYC

HEB-JL

N/A

HEB-JY

N/A

HEB-LL

HEB-LW-RLA

HEB-NN

N/A

HEB-PP(2)

N/A

HEB-QQ(2)

N/A

HEB-RR(2)

N/A

HEB-TT(2)

N/A

HEB-SS

N/A

(3)

(3)

(1)UL Recognized, Guide IZLT2, File E14853

(2)CSA Certified, Class 6225-01, File 47235

(3)CE

(4)HEB-AW-RLC-C is for (1) #4 stranded wire only.

Contact your local Bussmann representative for other possible 
terminations not listed.

Insulating boots for single conductor-2A0660
Dual conductor-2A0661

(4)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

312

Fuse Holders and Blocks

Panel Mounted Fuse Holders for 5 x 20mm Fuses

Specifications

Terminals:

Tin-plated brass.

Molded Materials:

High temperature thermoplastic that meets the flammability ratings of UL 94V0; Glow Wire Test:
960°C per IEC 60695-2-1.

Solderability:

In accordance with IEC 68-2-20.

Agency Information:

cURus, VDE

Electrical:

Contact Resistance: ≤ 10 megohm; Insulation Resistance: ≥ 10MΩ; Dielectric Strength ≥
2000Vac.

Shock Safety:

PC2 (fuse holders).

Packaging:

Standard Qty 10 (No Prefix), Bulk Qty 100 (Prefix Catalog Number with BK/).

3.0x0.51mm

12.00mm

+0.0
–0.1

12.70mm

+0.0

–0.1

12.00mm

+0.0
–0.1

12.70mm

+0.0

–0.1

12.00mm

+0.0
–0.1

12.70mm

+0.0

–0.1

12.00mm

+0.0
–0.1

12.70mm

+0.0

–0.1

3.0x0.51mm

3.0x0.51mm

4.8x0.51mm

37.5mm

4mm

Ø15mm

Ø16mm

11mm

5.5mm

Ø22mm

6.5mm

Ø15mm

37.5mm

36mm

4mm

Ø15mm

Ø16mm

11mm

5.5mm

0.5mm

35.5mm

4mm

Ø15mm

Ø16mm

11mm

5.5mm

0.5mm

10.2mm

Data Sheet: 2110

Data Sheet: 2110

Data Sheet: 2110

Data Sheet: 2110

HTC-35M

Ratings:

Volts: — 250Vac

Amps: — 10A UL, 6.3A VDE

Fuse Access: 

Threaded cap

HTC-55M

Ratings:

Volts: — 250Vac

Amps: — 10A UL, 6.3A VDE

Fuse Carrier:

Bayonet type

HTC-40M

Ratings:

Volts: — 250Vac

Amps: — 10A UL, 6.3A VDE

Fuse Access: 

Screwdriver slot

HTC-70M

Ratings:

Volts: — 250Vac

Amps: — 10A UL, 6.3A VDE

Fuse Carrier:

Bayonet type

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

313

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Panel Mounted Fuse Holders for 

1

4

" x 1

1

4

" Fuses

Specifications

Terminals:

Bayonet-type knob.
Vibration resistant.
For panels up to 

5

16

" (7.9mm) thick.

Agency Information:

CE (HKP, HKP-L, HKP-W, HKP-OO), UL Recognized — Guide IZLT2, File E14853, CSA 
Certified — Class 6225-01, File 47235

Replacement Parts:

Cap: 9435-1/2
Plastic Nut: BK/1A4287 (100 pieces minimum)
Metal Nut: BK/1A4806-2 (100 pieces minimum)
Washer: 9732

.800"

(20.3mm)

Punched Mounting Hole

.811"

(20.6mm)

.890"

(22.6mm)

1.56"

(39.7mm)

.75"

(19.1mm)

.855"

(21.7mm)

1.17"

F

U

SE

FU

S

E

FU

SE

Data Sheet: 2106

Data Sheet: 2106

Data Sheet: 2106

Specifications
Description:

Standard fuse holders.

Dimensions:

See Dimensions 

illustration.

Ratings:

Volts: — 250V

Amps: — 30A

Catalog Numbers

Catalog

Fuse

Numbers Description

HKP

HKP-L

HKP w/ 2250V stand-off barrier

HKP-W

HKP w/ drip-proof knob

Dimensions - in (mm)

Specifications
Description: 

Fuse holders with 

1

4

"

quick-connects.

Dimensions:

See Dimensions 

illustration.

Ratings:

Volts: — 250V

Amps: — 15A

Catalog Numbers

Catalog

Fuse

Numbers

Description

HKP-BBHH

HKP w/ 

1

4

" quick-connects, nut and washer 

assembled.

HKP-HH

HKP w/ 

1

4

" quick-connect.

HKP-LW-HH

HKP w/ drip-proof knob, 2250V stand-off 
barrier and 

1

4

" quick-connects.

Dimensions - in (mm)

Specifications
Description: 

Snap-lock fuse holders.

Dimensions:

See Dimensions 

illustration.

Ratings:

Volts: — 250V

Amps: — 30A

Catalog Numbers

Catalog

Fuse

Number

Description

HKP-OO

HKP with snap-lock

Dimensions - in (mm)

HKP, HKP-L, HKP-W

HKP-OO

HKP-BBHH, HKP-HH and
HKP-LW-HH

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

314

Fuse Holders and Blocks

Panel Mounted Fuse Holders for 5 x 20mm 
and 

1

4

" x 1 

1

4

" Fuses

HTB Series

Specifications
Description:

Fuse holders with knob-type carriers.

Dimensions:

See Dimensions illustrations.

Construction:

High temperature, flame retardant 

thermoplastic; UL Component Recognized; UL 94V0; 
mounting nut, spacer-black polycarbonate. Terminals: 
tin-plated brass.

Electrical Data:

Insulation resistance (per IEC #257) —

10,000 ohms @ 500Vdc; contact resistance (per IEC #257)
— 0.005 ohms Max @ 1A; standoff voltage (per IEC #257)
— 480V/Mil @ 0.125” thickness.

Agency Information:

CE, UL Recognized — Guide IZLT2,

File E14853, 

1

4

˝ dia fuse @ 20A, 5mm dia fuse @16A @

250V, CSA — 16A @ 250V Class 6225-01 File 47235; VDE
Certified: 136128, HTB-XXM, SEMKO Certification: Ref.
#0146149/01, HTB-XXM.

Mounting:

Withstands 15 to 20 Lb-In torque to mounting

nut when mounting fuse holder to panel.

Environmental:

Operating temperature range -55°C to

85°C.

Dimensional Data - in (mm)

Data Sheet: 2119

0.30”

HTB-22I-R

HTB-24I-R

HTB-26I-R

HTB-28I-R

X

7.62mm

HTB-22M-R

HTB-24M-R HTB-26M-R HTB-28M-R

X

0.125”

HTB-42I-R

HTB-44I-R

HTB-46I-R

HTB-48I-R

X

3.18mm

HTB-42M-R

HTB-44M-R HTB-46M-R HTB-48M-R

X

0.30”

HTB-62I-R

HTB-64I-R

HTB-66I-R

HTB-68I-R

X

7.62mm

HTB-62M-R

HTB-64M-R HTB-66M-R HTB-68M-R

X

0.125”

HTB-82I-R

HTB-84I-R

HTB-86I-R

HTB-88I-R

X

3.18mm

HTB-82M-R

HTB-84M-R HTB-86M-R HTB-88M-R

X

Fuse holders and fuse carriers may be ordered separately.

1.125"

(28.6mm)

0.47"

(11.9mm)

0.09" NOM.

(2.4mm)

1.125"

(28.6mm)

0.47"

(11.9mm)

0.92"

(23.4mm)

0.67"

(17.1mm)

0.91"

(23.0mm)

0.69"

(17.5mm)

Knob Type Carrier

Common Dimensions:
Length (Knob Type) - 1.69"
(42.9mm) Plus In-Line Terminal
NOTE: Plus In-Line Terminal

Maximum

Panel

Thickness

Solder/

3

16

" Quick-Connect

1

4

" Quick-Connect

Carrier Options

1

4

" x 1

1

4

"                5 x 20mm

(“I” Equals Inches)   (“M” Equals Metric)

Knob                    Knob

In-Line

Rt. Angle

In-Line

Rt. Angle

0.34"

(8.7mm)

0.33"

(8.3mm)

0.47"

(11.9mm)

0.45"

(11.5mm)

Terminal Options

Replacement Parts

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

315

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Panel Mounted Fuse Holders for 5 x 20mm
and 

1

4

" x 1 

1

4

" Fuses

0.30”

HTB-32I-R

HTB-34I-R

HTB-36I-R

HTB-38I-R

X

7.62mm

HTB-32M-R

HTB-34M-R HTB-36M-R HTB-38M-R

X

0.125”

HTB-52I-R

HTB-54I-R

HTB-56I-R

HTB-58I-R

X

3.18mm

HTB-52M-R

HTB-54M-R HTB-56M-R HTB-58M-R

X

0.125”

HTB-92I-R

HTB-94I-R

HTB-96I-R

HTB-98I-R

X

3.18mm

HTB-92M-R

HTB-94M-R HTB-96M-R HTB-98M-R

X

0.17"

(4.37mm)

1.58"

(40.03mm)

0.17"

(4.37mm)

1.59"

(40.08mm)

0.41"

(10.31mm)

1.34"

(34.13mm)

S

Packing 
Blank (Std.)

 – 10 fuse holders

in a carton 
 

BK 

– 100 fuse holders in a
cardboard shelf package 

Rear Terminal Configuration
2 — 

Solder /  

        

Quick-Connect

Solder / 

         

Quick-Connect

(In-Line)

4 — 

(Right Angle)

6 — 

Quick-Connect (In-Line)

8 — 

Quick-Connect (Right Angle)

Fuse Carrier
I — 

 

/

4

˝  

x 1

M — 

5 x 20mm

Splash Proof

(Optional on Knob

Holders Only) 

Body Configuration and Mounting 
Knob Holders 
2 — 

Low Profile (Rear Panel Hex-Nut)

4 — 

High Profile

*

6 — 

(Front Panel Hex-Nut)

8 — 

Low Profile (Snap-In)

Screwdriver Slotted Holders
3 — 

Low Profile

5 — 

High Profile

9 — 

Low Profile (Snap-In)

Product
Symbol

HTB-

Packaging 
(Blank) 

– Std.

BK/ 

– Bulk

Fuse Carrier
I — 
M — 

5 x 20mm

Product
Symbol
FT — 

Knob Type 

(For 20, 40, 60,
and 80 Series
Only)

ST —

Screwdriver

Slotted (For 30,
50, and 90 Series
Only)

P

-R

*Profile varies with panel thickness. Holder installs through rear of panel. 

FUSE CARRIER ONLY

1

 

/

4

˝  

1

 

/

4

˝  

1

 

/

4

˝  

1

 

/

16

˝  

3

 

/

16

˝  

3

Cap with O-Ring 

 

/

4

˝  

x 1

1

 

/

4

˝  

1

RoHS
Compliant

Data Sheet: 2119

Catalog Number Build-A-Code

HTB Series

HTB-3

HTB-5

HTB-9

Screwdriver Type Carrier

Common Dimensions:
(Screwdriver Slotted)
1.75" (44.5mm)
NOTE: Plus In-Line Terminal

Maximum

Panel

Thickness

Solder/

3

16

" Quick-Connect

1

4

" Quick-Connect

Carrier Options

1

4

" x 1 

1

4

"           5 x 20mm

(“I” Equals Inches)   (“M” Equals Metric)

Screwdriver         Screwdriver

In-Line

Rt. Angle

In-Line

Rt. Angle

0.34"

(8.7mm)

0.33"

(8.3mm)

0.47"

(11.9mm)

0.45"

(11.5mm)

Terminal Options

Dimensional Data - in (mm)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

316

Fuse Holders and Blocks

Panel Mounted Fuse Holders for Indicating Type Fuses

.630" + .005"

(16.0mm + .13mm)

.573" + .003"

(14.6mm + .08mm)

Punched Mounting Hole

Octagonal Sides

0.81"

(20.6mm)

1.19"

(30.2mm)

2.81"

(71.4mm)

Flat-Sides

Data Sheet: 2120

Data Sheet: 2121

Data Sheet: 2105

Specifications
Description: 

Pin indicating for 

1

4

" x 1

1

4

" fuses.

Dimensions:

See Dimensions 

illustration.

Ratings:

Volts: — 250V

Amps: — 15A

Agency Information:

CE, UL

Recognized, File E14853, Guide IZLT2.

Catalog Numbers

Catalog
Numbers*

Terminals

HLD

Solder terminals

HLD-HH

1

4

" quick-connect terminals

*Use w/GBA, GLD Fuses.

Dimensions - in (mm)

Specifications
Description: 

Neon lamp indicating for

1

4

" x 1" fuses.

Dimensions:

See Dimensions 

illustration.

Ratings:

Volts: — 250V

Amps: — 15A

Agency Information:

None

Catalog Number

Catalog

Lamp

Knob

Number*

Volts

Color

Type

HJL

90 to 250 Clear

Oct

*Use with AGX or MKB fuses, for panels up to 

1

8

" thick.

Dimensions - in (mm)

Specifications
Description: 

Neon and incandescent

lamp indicating for 

1

4

" x 1

1

4

" fuses

Dimensions:

See Dimensions

illustration.

Ratings:

Volts: — 250V

Amps: —15A (HKL, HKL-X)

— 20A (HKR, HKT, HKU, HKX)

Agency Information:

CE, UL

Recognized, (Guide IZLT2, File
E14853), CSA Certified 
(Class 6225-01, File 47235).

Catalog Numbers

Catalog

Lamp

Numbers

Volts

Knob Color/Type

HKL*

90-250

Clear/Oct

HKL-X*

90-250

Clear/FS

HKR**

22-30

Amber/Oct

HKT**

13-22

Amber/Oct

HKU**

4-6

Red/Oct

HKX**

22-33

Amber/FS

* Neon lamp — UL Recognized and CSA Certified.
** Incandescent lamp.

HLD

HK Series

HJL

Octagonal Sides

0.505" ± 0.005” 

(16.0mm ± 0.13mm) 

0.473" ± 0.005” 

(12.0mm ± 0.13mm) 

Punched Mounting Hole

0.69"

(17.5mm)

2.5" Ma

x

. (HLD)

(63.5mm Ma

x

.)

2.75" Ma

x

. (HLD-HH)

(69.9mm Ma

x

.)

0.86"

(21.8mm)

Washer

.630" + .005"

(16.0mm + .13mm)

.590" + .003"

(14.6mm + .08mm)

Punched Mounting Hole

Octagonal Sides

0.81"

(20.6mm)

1.19"

(30.2mm)

2.81"

(71.4mm)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

317

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Panel Mounted Fuse Holders for 

13

32

" x 1 

5

16

" to 1 

1

2

" Fuses

Data Sheet: 2114

Data Sheet: 2113

Data Sheet: 2108

0.180" DIA.

(4.6mm)

1.125"

(28.6mm)

1.00"

(25.4mm)

Without Fuse

2.69" Max.

(68.3mm)

0.88"

(22.2mm)

1.78"

(45.2mm)

1.31"

(33.3mm)

2.81" Max.

(71.4mm)

With Fuse

FU

SE

FU

S

E

F

U

SE

     0.250" 

±

 .003"

      (6.35 

±

 .08mm)

            (Typ.2)       

0.88"

(22.2mm)

2.81"

(71.4mm)

With Fuse

Without Fuse

2.41"

(64.3mm)

0.80"

(20.2mm)

1.78"

(45.2mm)

0.180"

(4.6mm)

1.125"

(28.6mm)

  0.250" 

±

 0.003"

     (6.35 

±

 .08mm)

           (Typ.2)       

1.125"

(28.6mm)

0.88"

(22.2mm)

2.81"

(71.4mm)

Specifications
Description:

Standard fuse holders

with 

screw-type knob

for 

13

32

" x 1

5

16

" to

1

1

2

" Fuses.

Dimensions:

See Dimensions 

illustration.

Agency Information:

CE, UL

Recognized, Guide IZLT2, File E14853;
CSA Certified, Class 6225-01, File
47235.

Flammability Rating:

UL 94HB.

Terminals:

Combination 

1

4

quick-connect/solder terminals.

Catalog Numbers

Catalog

Amp

Numbers Ratings Volts AC Fuse Description

HPF

30

2

600

1

2

" (38.1mm)

HPF-C

30

3

600

3

1

2

" (38.1mm) clear knob.

HPF-L

5

600

BBS, 

13

32

" x 1 

3

8

" fuses.

HPF-EE

15

600

SC 0-15, 

13

32

" x 1 

5

16

" fuses.

HPF-JJ

20

600

SC 20, 

13

32

" x 1 

13

32

" fuses.

HPF-FF

1

30

2

480

SC 25 & 30, 

13

32

" x 1 

5

8

" fuses.

HPF-RR

30

2

600

KTK-R, LP-CC & FNQ-R
Class CC fuses.

HPF-WT

30

2

600

Splash-proof knob. 

13

32

" x 1 

1

2

"

(38.1mm)

1

No CSA Certification

2

20A max when used with quick-connect terminals.

3

HPF-C ratings for CSA-15A, 250V

Dimensions - in (mm)

Specifications
Description:

Standard fuse holders

with 

bayonet-type knob

for 

13

32

" x 1

5

16

"

to 1

1

2

" fuses.

Dimensions:

See Dimensions 

illustration.

Agency Information:

CE, UL

Recognized, Guide IZLT2, File E14853;
CSA Certified, Class 6225-01, File
47235.

Flammability Rating:

UL 94HB.

Terminals:

Combination 

1

4

" quick-

connect/solder terminals.

Catalog Numbers

Catalog

Amp

Symbol

Ratings Volts AC Fuse Description

HPS

30

2 3

600

13

32

" x 1 

1

2

"

HPS-L

5

600

BBS, 

13

32

" x 1 

3

8

" fuses.

HPS-EE*

15

600

SC 0-15, 

13

32

" x 1 

5

16

" fuses.

HPS-JJ*

20

600

SC 20, 

13

32

" x 1 

13

32

" fuses.

HPS-F-EE

1

15

600

Sleeve on body, leaded for

13

32

" x 1

5

16

" fuses.

HPS-FF*

1

30

2

480

SC 25 & 30, 

13

32

" x 1 

5

8

" fuses.

HPS-RR*

1

30

2

600

KTK-R, LP-CC, FNQ-R Class
CC fuses.

*-EE, -JJ, -FF and -RR versions are UL Recognized for
applications requiring branch circuit protection.

1

No CSA Certification

2

20A max when used with quick-connect terminals.

3

HPS rated at 250V for CSA

Dimensions - in (mm)

Specifications
Description:

Standard fuse holders

with 

bayonet-type knob

for 

13

32

" x 1

1

2

"

fuses.

Dimensions:

See Dimensions 

illustrations.

Agency Information:

CE, UL

Recognized, (Guide IZLT2, File
E14853).

Flammability Rating:

UL 94V0 - fuse

holder body UL 94HB - Knob.

Catalog Numbers

Catalog

Amp

Numbers Ratings Volts AC  Fuse Description

HPG*

30

1

600

13

32

" x 1 

1

2

" fuses

HPG-EE* 15

600

SC 0-15, 

13

32

" x 1 

5

16

" fuses.

HPD**

30

1

600

13

32

" x 1 

1

2

" fuses

1

20A max when used with quick-connect terminals.

*HPG and HPG-EE has combination 

1

4

" quick-connect/solder

terminals on both side (load) and rear (line) terminals.
**HPD has combination 

1

4

" quick-connect/solder terminal on

side (load) terminal only. Rear (line) terminal is 

3

16

" shorter

than HPG. Rear terminal solder only.

Dimensions - in (mm)

HPG, HPG-EE

HPD

HPF

HPD

HPG

HPS

#10 wire max 

for solder connection

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

318

Fuse Holders and Blocks

Panel Mounted Fuse Holders for 

13

32

" x 1 

1

2

" Fuses

Data Sheet: 2112

Data Sheet: 2109

Data Sheet: 2140

Panel Mount Hole Dimensions

1.41"

(30.6mm)

0.94"

(23.8mm)

With Fuse

Without Fuse

2.73"

(69.5mm)

2.594"

(65.89mm)

  0.250" 

±

 0.003"

  (6.35 

±

 0.08mm)

1.031" + 0.003"

(26.2mm + 0.08mm)

0.187" + 0.002"

(4.75mm + 0.05mm)

Mounting Hole
Flange Rear of Panel

Mounting Hole
Flange Front of Panel

0.890" + 0.003"

(22.6mm + 0.08mm)

1.312" + 0.003"

(33.3mm + 0.08mm)

1.312" + 0.003"

(33.3mm + 0.08mm)

1.775"

(45.1mm)

0.180"

(4.6mm)

1.120"

(30.5mm)

0.88"

(22.2mm)

2.48"

(63.1mm)

With Fuse

Specifications
Description:

Standard fuse holder

with 

screw-type knob

for 

13

32

" x 1

1

2

"

fuses.

Dimensions:

See Dimensions 

illustration.

Ratings:

Volts: — 600Vac/dc

Amps: — 30A

1

1

20A max when used with quick-connect terminals.

Agency Information:

CE, UL

Recognized, Guide IZLT2, File E14853;
CSA Certified, Class 6225-01, File
47235.

Flammability Rating:

UL 94HB.

Catalog Numbers

Catalog
Numbers

Description

HPM

1

4

" quick-connect/solder

HPM-D

Splash-resistant knob

2

2

HPM-D has 

1

4

"

quick-connect/solder terminal on rear (load)

terminal only. The side (line) terminal is 

1

4

" quick-

connect only.

Dimensions - in (mm)

Specifications
Description: 

Fuse holder with 

screw-type knob

for 

13

32

" x 1

1

2

" fuses.

Supplied with O-ring and panel gasket.

Dimensions:

See Dimensions 

illustration.

Ratings:

Volts: — 600Vac/dc

Amps: — 30A

1

1

20A max when used with quick-connect terminals.

Agency Information:

CE, UL

Recognized, Guide IZLT2, File E14853.

Flammability Rating:

UL 94HB.

Catalog Numbers

Catalog
Number

Description

HPC-D

Mount in panels up to 

1

4

" thick.

Replacement knob - BK/9987SA

Dimensions - in (mm)

Specifications
Description:

For fuse size 

13

32

" x 1

1

2

",

meeting UL 1598 requirement that both
poles be removed simultaneously.

Dimensions:

See Dimensions 

illustration.

Ratings:

Volts: — 600V@30A

Amps: — 0-30A 

1

1

20A max when used with quick-connect terminals.

Agency Information:

UL 4248 

recognized, (Guide IZLT2, File
E14853), CSA certified: 
(Class 6225-01, File 47235).

Flammability Rating:

UL 94V0.

Terminals:

1

4

” quick-connect/solder.

Catalog Numbers

Catalog
Numbers

HPS2

Standard 10-in carton

BK/HPS2

Bulk 100-in carton

Dimensions - in (mm)

HPM

HPC-D

HPS2

#10 wire max 

for solder connection

Nut Torque:

30 lb-in.

Replacement Knob:

Catalog Number: BK/9789-Y2 
(50 pieces)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

319

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Fuse Blocks for 

1

4

" x 1 

1

4

" Fuses

4405 - 

0° Solder terminals

with integral terminal and clip

Dimensions - in (mm)

Note: Mounting screw hole diameter is 0.147" (3.7mm).
Counterbore diameter, 0.636" (8.0mm). Max Mounting 
Screw No. 6.

Specifications

Description:

Bolt-in and snap-in mounting for 

1

4

" x 1

1

4

"

fuses.

Construction:

Blocks are molded flame retarded 

thermoplastic. Clips are spring-bronze.

Ratings:

Volts: — 300V

Amps: — 25A (See Catalog Numbers table)

Agency Information:

CE, UL Recognized ; File E14853,

Guide IZLT2, CSA Certified Class 6225-01, File 47235.

Anti-Rotation Pin:

Single-pole blocks may be ordered 

without the anti-rotational pin simply by adding an “X” to the
number of poles (Example: BK/S-8000-1X).

Carton Quantity:

10; shelf package: 100.

Bulk Carton:

Single-pole and 2-pole fuse blocks – 1,000;

Multiple-pole fuse blocks – 3- to 8-pole: 200; 9- to 12-pole:
50. When ordering bulk quantities, prefix “BK/” to catalog
number: (Example: BK/S-8001-1-SNP).

2.31"

(58.7mm)

1.63"

(41.3mm)

0.27"

(6.7mm)

0.69"

(17.5mm)

Catalog Numbers

Bolt-in Mounting

Basic
Catalog

Agency

Poles

Numbers

Series

Terminal

Angle

Maximums

(Suffix)

S-8001-

8000

Solder

UL 25A

1 - 12

S-8002-

40°

CSA 21A

S-8101-

8100

3

16

" Quick

UL 20A

S-8102-

Connect

40°

CSA 13A

S-8201-

8200

1

4

" Quick

UL 20A

S-8202-

Connect

40°

CSA 16A

S-8203-

Side

S-8301-

8300

Screw

UL 30A
CSA 25A

Snap-in Mounting

Catalog

Agency

Poles

Numbers

Series

Terminal

Angle

Maximums

(Suffix)

S-8001-1-SNP

8000

Solder

UL 25A

Available

S-8002-1-SNP

40°

CSA 21A

only in

S-8101-1-SNP

8100

3

16

" Quick

UL 20A

single

S-8102-1-SNP

Connect

40°

CSA 13A

pole

S-8201-1-SNP

8200

1

4

" Quick

UL 20A

S-8203-1-SNP

Connect

Side

CSA 16A

Catalog Number Build-A-Code

4406 - 

Side solder terminal

4574 - 

Spare fuse block

Dimensions - in (mm)

2499 - 

Side quick-connect

Agency Information:

UL

Recognized, Guide IZLT2, File
E14853

Terminals:

1

4

" (6.4mm); 15A, 250V

Dimensions - in (mm)

Series 8000

Data Sheet: 2101

1.63"

(41.3mm)

0.27"

(6.7mm)

0.69"

(17.5mm)

0.27"

(6.7mm)

0.75"

(19.1mm)

0.5"

(12.7mm)

0.72"

(18.3mm)

1.63"

(41.3mm)

Single-Pole Fuse Blocks

Specifications

Description:

Single-pole fuse block for 

1

4

" x 1

1

4

(6.4 x 31.8mm) size fuses.

Dimensions: 

See Dimensions illustrations.

Construction:

Bakelite base width 

1

2

" (12.7mm); spring-

bronze, bright tin-lead plate clips.

Ratings:

Volts: — 250V

Amps: — 30A

8000

8000

Available

only in

single

pole

1 - 12

8100

8100

8300

8200

8200

Catalog Code

BK/

S-8 0

00

-00

Prefix

 

for

B

ulk

Packing

Series

 

8000

Product

 

Line

 

Terminal

 

Angle

“01”

 

-

 

straight

 

(0,)

 

“02”-

 

40

“03”

 

-

 

side*

Type

 

Terminal

“0”-Solder
“1”-

 

 

¡§∑ 

Quick

 

Connect

  

“2”

 

-

 

 

¢∑ 

Quick

 

Connect

  

“3”

 

-

 

Screw

 

Number

 

of

 

Poles

 

(1-12)

*Available

 

only

 

in

 

single

 

pole

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

320

Fuse Holders and Blocks

No. 4520 -

Integral clip and straight solder 

terminals

Fuse Blocks for 

1

4

" x 1" Fuses

0.19"

(4.8mm)

0.63"

(15.9mm)

1.88"

(47.6mm)

1.38"

(34.9mm)

1.94"

(49.2mm)

1.38"

(34.9mm)

 .188"

(4.8mm)

  .598"

(15.2mm)

1.38"

(34.9mm)

0.188"

(4.8mm)

0.598"

(15.2mm)

No. 4393 - 

Spare fuse block

3828 Series

4520 and 4393

Specifications
Description:

Fuse block for 

1

4

" x 1" (6.4 x 25.4mm) fuses

with solder terminals.

Dimensions: 

See Dimensions illustration.

Ratings:

Volts: — 250V

Amps: — 30A

Mounting:

Mounting screw hole diameter is 0.147"

(3.7mm),  diameter. Max mounting screw No. 6.

Catalog Numbers

Catalog Numbers

Poles

*Base Length - in (mm)

3828-1

1

1

(12.7)

3828-2

2

1

8

(28.6)

3828-3

3

3

4

(44.5)

3828-4

4

3

8

(60.3)

3828-5

5

3 (76.2)

3828-6

6

5

8

(92.1)

3828-7

7

1

4

(108.0)

3828-8

8

7

8

(123.8)

3828-10

10

1

8

(155.6)

3828-12

12

3

8

(187.3)

*Small phenolic base, base width 1 

3

8

" (34.9mm)

Dimensions - in (mm)

Specifications
Description:

Single-pole fuse block for 

1

4

" x 1" fuses.

Dimensions: 

See Dimensions illustrations.

Construction:

Bakelite with 

1

2

" (12.7mm) width base.

Spring-bronze, bright tin-lead plated clips.

Ratings:

Volts: — 250V

Amps: — 30A

Mounting:

Mounting screw hole diameter is 0.147"

(3.7mm), counterbore 0.636" (8.0mm) diameter. Max 
mounting screw No. 6.

Catalog Numbers

Catalog
Numbers

Description

4520

Integral clip and straight solder terminals

4393

Spare fuse block

Dimensions - in (mm)

Dimensions - in (mm)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

321

Fuse Holder

s

& Blocks

Fuse Holders and Blocks

Blocks for 

13

32

" X 1

1

2

" Fuses

Specifications

Description:

Add-on fuse blocks for

13

32

" X 1 

1

2

" (10.3 X 38.1mm) fuses.

Single pole blocks lock into each other
and can be added at any time. Each
has a single end barrier.

Dimensions: 

See Dimensions 

illustration.

Ratings:

Volts: — 600Vac/dc

Amps: — 30A

Agency Information:

CE, UL

Recognized Guide IZLT2, File E14853.

3742—End Barrier Only

3723—Block and end barrier 

marking strip. Length is 9

3

8

"

(23.8cm). 

Note: Mounting screw hole is 0.147"
(3.7mm) dia. Counterbore, 0.636"
(8mm) dia. Max. mounting screw No. 6.

Specifications

Description:

Single pole fuse blocks

for 

13

32

" X 1 

1

2

" (10.3 X 38.1mm) fuses.

Dimensions: 

See Dimensions 

illustration.

Ratings:

Volts: — 250Vac/dc (or less)

Amps: — 30A

Agency Information:

CE

4421—Solder Terminals 

Base width 

5

8

" (15.9mm)

4515—Screw Terminals 

Base width 

3

4

" (19mm)

Note: Mounting screw hole diameter is
0.147" (3.7mm). Countersink, 0.312"
(7.9mm). Max. mounting screw No. 6.

Specifications

Description:

Multiple pole fuse blocks

for 

13

32

" X 1 

1

2

" (10.3 X 38.1mm) fuses.

Dimensions: 

See Dimensions 

illustration.

Ratings:

Volts: — 250Vac/dc

Amps: — 30A

Agency Information:

CE

Catalog Numbers

Catalog

Base* Width

Numbers

Poles

In (mm)

3835-1

1

27

32

(21.4)

3835-2

2

13

16

(46.0)

3835-3

3

25

32

(70.6)

3835-4

4

3

4

(95.2)

3835-5

5

23

32

(119.9)

3835-6

6

11

16

(144.5)

3835-7

7

21

32

(169.0)

3835-8

8

5

8

(193.7)

3835-9

9

19

32

(218.8)

3835-10

10

9

16

(242.9)

3835-12

12

11 

1

2

(292.1)

*Base length: 2 

3

4

" (69.9mm)

Dimensions - in (mm)

Note: Mounting screw hole diameter is
0.148" (3.7mm). Countersink, 0.313"
(7.9mm). Max. mounting screw No. 6.

3 7 4 2

0.25"

2.56"

1.125"

1.29"

0.84"

0.500"

1.125"

(28.6mm)

2.56"

(65.1mm)

0.78"

(19.8mm)

1.34"

(34.1mm)

0.25"

(6.4mm)

0.323"

(8.2mm)

0.144"

0.19"

(4.8mm)

0.897"

(22.78mm)

2.5"

(63.5mm)

1.63"

(41.3mm)

2.56"

(65.1mm)

0.19"

(4.8mm)

 0.897"

(22.78mm)

2.75"

(69.9mm)

0.25"

(6.4mm)

1.0"

(25.4mm)

3743

4421 and 4515

3835 Series

Data Sheet: 2104

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

322

Fuse Holders and Blocks

NDNF1-WH

Specifications

Description:

Fuse holding rail

mount terminal block.

Circuit Jumper:

JF1, 

2 circuits

Fuse Size:

13

32

" X 1

1

2

"*

(KTK, FNQ, PVM).

Poles:

1

Wire Range:

AWG #8-22 Cu.

Ratings:

Volts: — 600V

Amps: — 30A

Mounting Options

:  35mm DIN-Rail, C-rail

Fuse Pullers

:  • PF1 (standard)

• neon or incandescent bulb

*LPF1 (lighted neon or incandescent bulb).

Torque Rating

:  18 lb-in

Operating Temperature

:  105°C

Catalog Numbers

Catalog

Number

Color

NDNF1-WH

White

Fuse Pullers (Optional):

PF1

Lighted neon or incandescent lamp:

Catalog

Numbers

Voltage

LPF1-24

24

LPF1-120

120

LPF1-120-C

120

LPF1-220

220

LPF1-440

440

NDNLFD1-WH

Specifications

Description:

Rail mount

fuse holder.

Circuit Jumper:

JF1, 

2 circuits.

Fuse Size:

1

4

" X 1

1

4

"

(Bussmann AGC, MDL or
equivalent).

Poles:

1

Wire Range:

AWG #8-22 Cu.

Ratings:

Volts: — 600V

Amps: — 30A (NDND1 non-fused)

— 15A (NDNFD1, 600V/CSA, fused)

— 15A (NDNLFD1*fused, indicating)

*WH24 - 24V White, WH-90Vdc-600Vdc, 115Vac-600Vac White

Agency Information:

CE

Mounting Options

:  35mm DIN-Rail, C-rail

Marking Tape

:  MT12-1-2

Torque Rating

:  18 lb-in

Operating Temperature

:  105°C

Agency Information

:  CSA File 15364

Catalog Numbers

Catalog

Number

Color

Indicator

NDND1-WH

White

NO

NDNFD1-WH

White

NO

NDNLFD1-WH

White

90Vdc-600Vdc
115Vac-600Vac

NDNLFD1-WH 24

White

24V

Rail Mount Fuse Blocks and Holders

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

323

P

o

wer Distrib

ution

& T

er

minal Blocks

Power Distribution &
Terminal Blocks

Section Contents

Page

Selection table for SCCR PDBs & Power 

terminal blocks  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324

Power distribution blocks  

Series PDBFS enclosed, with high SCCR . . . . . . . . . . . . 325
Series PDB with high SCCR  . . . . . . . . . . . . . . . . . . . . . 326

Power terminal blocks  

Series 163 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327-328

Series 11675 2- to 12-Pole quick-connect . . . . . . . . . . . 329

Series 11725 2- to 4-Pole quick-connect . . . . . . . . . . . . 329

Series 160, 162, 163 & 165 . . . . . . . . . . . . . . . . . . . . . . 329

Series 162, 163 & 165 power stud terminal blocks . . . 330

Series 160, 162, 163 & 165 power splicer blocks . . . . 330

Series 14002 Barrier terminal blocks . . . . . . . . . . . . . . 331

Series 14004 Dead front terminal block . . . . . . . . . . . . 331

Scan this tag to get the

latest product information for the

Power Distribution Blocks.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

324

Power Distribution & Terminal Blocks

Selection Table for SCCR Power Distribution Blocks and
Power Terminal Blocks

Short-Circuit Current Rated Power Distribution
Blocks

Bussmann offers three distinctly different styles of  short-
circuit current rated power distribution blocks (PDBs) and
power terminal blocks (PTBs) to match different 
application needs. The differences are whether the power 
distribution blocks are enclosed or not, and whether they are
UL 1953 Listed PDBs or UL 1059 Recognized PTBs, which
have different minimum spacing requirements. The table on
this page can assist in the selection of  the right series for
your application requirements.

Why these are important?

Assembly short-circuit current ratings (SCCRs) are now
required in the 2011 NEC

®

and UL 508A Listed Industrial

Control Panels. Marking the SCCR on Industrial Control
Panels (NEC

®

409.110), Industrial Machinery Electrical

Panels (NEC

®

607.3(A)), and HVAC equipment (NEC

®

440.4(B)) is required by the National Electrical Code. PDBs or
PTBs not marked with a SCCR, typically are the weakest link
and may limit an assembly to no more than 10kA SCCR. The
PDBFS and PDB Series have increased spacing required
where used in feeder circuits in equipment listed to UL508A
(UL1059 PTBs must be evaluated for proper spacings). Also,
for building wiring systems, the PDBFS Series and PDB
Series power distribution blocks can be used to meet the new
2013 NEC

®

requirements in section 376.56(B) for PDBs in

wireways.

Industrial

Industrial

Control

Control

HVAC

Wireways

Description

Catalog

High

Spacing**

Panels

Panels

UL

NEC

®

Page

UL

Enclosed SCCR*

1” Air

UL 508A

UL 508A

1995

376.56(B)

2” Surface

Branch

Feeder

(Requires

Circuit

Circuit

UL 1953)

Series PDBFS

325

UL 1953 Listed

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Series PDB

326

UL 1953 Listed

No***

Yes

Yes

Yes

Yes

Yes

w/optional

cover

Selection Table

† IP20 Finger-safe under specific conditions, see datasheet 1149. 

*When protected by proper fuse class with maximum ampere rating specified or less.

**See 

PDB Spacing Requirements for Equipment

table below.

***Optional covers are available. Not IP20, but provide a safety benefit.

****No, except: Yes, if  single pole units installed with proper spacings.

Spacing between

Spacing between

live parts of

live parts and

UL Standard

opposite polarity

grounded parts

or enclosure

@600V

508A Feeder

Circuits

508A Branch

Circuits

1995 HVAC

Through air

Over surface

@600V

@600V

3

8

˝

1

2

˝

1

2

˝

3

8

˝

1

2

˝

1

2

˝

Note: Refer to Specific UL standards for complete spacing details.

PDB & PTB Minimum Spacing 

Requirements for Equipment

Data Sheet: 1049

Series PDBFS

Series PDB

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

325

P

o

wer Distrib

ution

& T

er

minal Blocks

Series PDBFS of Power Distribution Blocks

Feature/Benefits

• Enclosed, safer 

installation; IP20 
finger-safe under specific
conditions

• High short-circuit current 

ratings up to 200kA: 
PDBs do not have to be 
the weak link in achieving 
high SCCR for an 
industrial control panel

• Small footprint saves 

panel space

• Listed to UL 1953 which has minimum spacing 

requirements at 600V of  at least 1” through air and 2” over 
surface required for feeders in UL 508A Industrial Control 
Panels 

• For 2D CAD drawings visit www.cooperbussmann.com

Agency/Standards

• UL Listed 1953, Guide QPQS, File E256146 
• CSA Certified, Class 6228-01, File 47235
• IEC 60947-7-1
• IEC 60529, IP20 (finger-safe) under specific wiring 

conditions

Electrical 

• 600Vac/dc (UL 1953), 690Vac/dc (IEC) 
• IP20 finger-safe under specific conditions
• Short-circuit current ratings up to 200kA, see table 
• Ampacities up to 760 amps
• Cu wire range 14 AWG to 500 kcmil or 2.5 to 240 mm

2

Mechanical 

• DIN-Rail or panel mount; PDBFS330 & PDBFS504 panel 

mount only

• Captive termination screws; screws do not get misplaced
• Wire ready: captive termination screws shipped backed out

to save time on conductor installations

• Sliding DIN-Rail latch for easy mounting 
• Single pole, gang mountable for multiple pole applications 

with interlocking dovetail accessory (optional)

• Flammability, UL 94V0
• Tin-plated Al connectors suitable for Cu conductors
• Elongated hole for panel mounting; easier mounting with

greater flexibility in matching up with drilled panel holes

• Part 2A1279: Interlocking dovetail pin accessory

One pin interlocks two units, two pins to interlock three units

• DIN-Rail end anchors required to prevent damage to block 

when torquing

Data Sheet: 1049

Power Distribution & Terminal Blocks

Terminal Copper Conductor Capability                                        Short-Circuit Current Rating Data

Line                      Load

Configuration

Conductors          Max Fuse Class & Amp**

Catalog

Number

Openings per Pole

Line

Load

J

T

RK1

RK5

(All Single

Amps

Wire Range

Wire Range

AWG or

AWG or

LPJ

JJS

LPS-RK

FRS-R

SCCR

Pole)

Line    Load

kcmil

kcmil

JJN

LPN-RK

FRN-R

PDBFS204

175A

2/0 to 8 AWG

2/0 to 8 AWG

2/0 to 8

2/0 to 8 200

200

100

60

200kA

70 to 10 mm

2

70 to 10 mm

2

2/0 to 8 AWG

4 to 14 AWG

4 to 12 200

200

100

60

200kA

PDBFS220

175A

70 to 10 mm

2

25 to 2.5 mm

2

2/0 to 8

4 to 14

175

175

100

30

100kA

200

200

100

60

50kA

350kcmil to 6 AWG 350kcmil to 6 AWG

PDBFS303

310A

185 to 16 mm

2

185 to 16 mm

2

350 to 6

350 to 6 400

400

200

100

200kA

500kcmil to 6 AWG

2 to 14 AWG

2 to 6

400

400

200

100

200kA

PDBFS330

380A

240 to 16 mm

2

35 to 2.5 mm

2

500 to 6

2 to 14

200

200

100

60

50kA

175

175

100

30

100kA

300kcmil to 4 AWG

4 to 14 AWG

300

4 to 8

600

600

400

200

200kA

PDBFS377

570A

150 to 12 mm

2

25 to 2.5 mm

2

300 to 4

4

400

400

200

100

100kA

4 to 14 200

200

100

60

50kA

PDBFS500

620A

350kcmil to 4 AWG 350kcmil to 4 AWG

350 to 4

350 to 4 600

600

400

200

200kA

185 to 12 mm

2

185 to 12 mm

2

500kcmil to 6 AWG 500kcmil to 6 AWG

500

500

600 800*

600

200

200kA

PDBFS504

760A

240 to 16 mm

2

240 to 16 mm

2

500 to 6

500 to 6 600

600

400

200

100kA

Ampacities 75C per NEC® Table 310.16 and UL508A Table 28.1
*Class L 800A (KRP-C 800_SP) or less fuses suitable for this particular SCCR case.
** Class G 60A (SC-60) or less or Class CC 30A (LP-CC-30, FNQ-R-30, KTK-R-30) or less are suitable for all SCCRs in this table.

Series PDBFS

Electrical

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

326

Power Distribution & Terminal Blocks

Series PDB of Power Distribution Blocks

Feature/Benefits

• High short-circuit current ratings up to 200kA. These 

PDBs do not have to be the weak link in achieving high 
SCCR for an industrial control panel

• Listed to UL 1953 which has minimum spacing 

requirements at 600V of  at least 1” through air and 2” over 
surface required for feeder in UL 508A Industrial Control 
Panels   

• For 2D CAD drawings visit www.cooperbussmann.com

Agency/Standards

• UL Listed 1953, Guide QPQS, File E256146 

Electrical

• 600Vac/dc (UL 1953) 
• Short-circuit current ratings up to 200kA, see table  
• Wire range 14 AWG to 350 kcmil Cu 
• Spacing between uninsulated opposite polarities or ground

meets UL 1953 which requires at least 1” through air and 
2” over surface 

• Ratings available with circuit breakers 

Mechanical

• Panel mount
• Flammability, UL 94V0
• Tin-plated Al connectors suitable for Cu conductors

Terminal Copper Conductor Capability                                        Short-Circuit Current Rating Data

Line                      Load

Configuration

Conductors          Max Fuse Class & Amp*

Catalog

Number

Openings per Pole

Line

Load

J

T

RK1

RK5

Amps

Wire Range

Wire Range

AWG or

AWG or

LPJ

JJS

LPS-RK

FRS-R

SCCR

Pole

Line       Load

kcmil

kcmil

JJN

LPN-RK

FRN-R

PDB204-1
PDB204-3

175A

2/0 - 8 AWG

2/0 - 8 AWG

2/0 - 8

2/0 - 8

200

200

200

60

200kA

4 - 12

200

200

200

60

200kA

PDB220-1

175A

2/0 - 8 AWG

4 - 14 AWG

2/0 - 8

14

175

175

100

60

100kA

PDB220-3

200

200

100

60

50kA

PDB280-1

175A

2/0 - 8 AWG

1/4-20 X 3/4 STUD

2/0 - 8

Stud

200

200

100

60

200kA

PDB280-3

PDB321-1

4 -12

400

400

200

100

200kA

PDB321-2

175A

2/0 - 8 AWG

4 - 14 AWG

2/0 - 8

400

400

400

100

100kA

PDB321-3

14

175

175

100

60

100kA

PDB323-1

400

400

200

100

200kA

PDB323-3

310A 300kcmil - 4 AWG

4 - 12 AWG

300 - 4

4 - 8

400

400

400

100

100kA

10 - 12 175

175

100

60

100kA

PDB370-1

4 - 8

400

400

200

100

200kA

PDB370-3

310A 350kcmil - 4 AWG

4 - 14 AWG

350 - 4

10 - 14

400

400

400

100

100kA

175

175

100

60

100kA

PDB371-1

1/0 - 6

400

400

200

100

200kA

PDB371-3

310A 350kcmil - 4 AWG

(6) 2 - 12 AWG

350 - 4

400

400

400

100

100kA

(3) 1/0-12

8 - 12

175

175

100

60

100kA

Ampacities 75ºC per NEC® Table 310.16 and UL508A Table 28.1
* Class G 60A (SC-60) or less or Class CC 30A (LP-CC-30, FNQ-R-30_SP, KTK-R-30) or less are suitable for all these SCCR in this table.
† Higher SCCR may be available, check data sheet 1049.

Series PDB

Data Sheet: 1049

Optional covers

Covers are ordered for each individual pole, i.e., three 
1-pole covers for 3-pole block, see table A.
Except PDB321 blocks have one cover for 1-, 2- or 3-pole 
versions, see table B.

Table A                                Table B

Block

Cover

Block

Cover

PDB2XX-(pole): CPB162-1

PDB321-1

CPDB-1

PDB3XX-(pole): CPDB-1

PDB321-2

CPDB-2

PDB321-3

CPDB-3

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

327

P

o

wer Distrib

ution

& T

er

minal Blocks

163 Series

Replaces Bussmann 164 Series

Specifications

Description:

Power terminal

block.

Dimensions:

See Dimensions

illustrations.

Construction:

Tin-plated 

aluminum connectors.

Poles:

1- to 3-Poles, See

Catalog Numbers table on the
following page.

Wire Range:

See Catalog

Numbers table on the following
page.

Ratings:

Volts: — 600Vac/dc

Amps: — See catalog Numbers table on the following page.

SCCR:— 10kA per UL 508A table SB4.1 (except for select

products noted in table)

Agency Information:

CE, UL Recognized: Guide XCFR2,

UL E62622, General Industrial Class per UL1059, CSA
Certified: CSA 053787

Flammability Rating:

UL 94V0 

Dimensions

Series 163 Power Terminal Blocks

1-pole

1.96"

2-pole

3.58"

3-pole

5.20"

.31"

1.62"

3.25"

Mtg. hole 0.21 x 0.41,

c'bore 0.42 x 0.62 x 0.12 deep

3.32"

0.97"

4.00"

3.37"

Supplied with (4) #4 thread-cutting 

 screws assembled as shown

Textured surface for marking

CPDB-1   (single pole)    2.10"
CPDB-2   (two pole)        3.72"
CPDB-3   (three pole)     5.34"

4.14"

(See Following Page for Ratings)

Data Sheet: 1049

Power Distribution & Terminal Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Series 163 Power Terminal Blocks

Catalog Numbers

Basic
Catalog

Wire Size

Amps/

Numbers

(Poles) Lineside

(Poles) Loadside

Pole

Line/Load

16301*

250kcmil-6 AWG Cu Only

250kcmil-6 AWG Cu Only

255

16303

350kcmil-6 AWG Cu-Al

350kcmil-6 AWG Cu-Al

310

16306

500kcmil-6 AWG Cu-Al

500kcmil-6 AWG Cu-Al

380

16321**

2/0-14 AWG CU, 2/0-8Al

(6)4-14 AWG Cu, 4-8 AWG Al

175

16323**

350kcmil-6 AWG Cu-Al

(6)4-14 AWG Cu, 4-12 AWG Al

310

16325

(2)2/0-14 AWG Cu, 2/0-8 AWG Al

(6)4-14 AWG Cu, 4-8 AWG Al

350

16330

500kcmil-6 AWG Cu-Al

(6) 2-14 AWG Cu, 2-12 AWG Al

380

16332

350kcmil-6 AWG Cu-Al

(3) 2-14 AWG Cu, 2-8 AWG Al

310

(2) 1/0-14 AWG Cu, 1/0-8 AWG Al

16335

500kcmil-6 AWG Cu-Al

(3) 2-14 AWG Cu, 2-8 AWG Al

380

(2) 1/0-14 AWG Cu, 1/0-8 AWG Al

16370**

350kcmil-6 AWG Cu-Al

(12)4-14 AWG Cu, 4-12 AWG Al

310

16371**

350kcmil-6 AWG Cu-Al

(6) 2-14 AWG Cu, 2-8 AWG Al

310

(3) 1/0-14 AWG Cu, 1/0-8 AWG Al

16372

350kcmil-6 AWG Cu-Al

(21) 10-14 AWG Cu, 10 AWG Al

310

16373

350kcmil-6 AWG Cu-Al

(14) 10-14 AWG Cu, 10 AWG Al

310

(3) 1/0-14 AWG Cu-Al

16375

600kcmil-2 AWG Cu-Al

(12)4-14 AWG Cu, 4-12 AWG Al

420

16376

600kcmil-2 AWG Cu-Al

(6) 2-14 AWG Cu, 2-8 AWG Al

420

(3) 1/0-14 AWG Cu, 1/0-8 AWG Al

16377

(2)300kcmil-4 AWG Cu-Al

(12)4-14 AWG Cu, 4-12 AWG Al

570

16378

500kcmil-6 AWG Cu-Al

Stud Size (2) 1/4-20 x 1

380

16383

500kcmil-6 AWG Cu-Al

Stud Size (1) 3/8-16 x 1

380

16390

3

8

-16 x 1

1

8

Stud Size

3

8

-16 x 1

1

8

Stud Size

250

16394

1

2

-13 x 1

1

16

Stud Size

1

2

-13 x 1

1

16

Stud Size

400

16395

3

8

-16 x 1

7

16

Stud Size

(2) 

1

4

-20 x 

9

16

Stud Size

310

*Copper connectors for use with copper wire only.
**SCCR up to 200kA

Ordering Information

163 Series blocks are available in 1-, 2- or 3-poles. To order: Basic Catalog Number + Number of poles.

Examples:

16301-1 = one-pole block

16301-3 = three-pole block

Data Sheet: 1049

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

328

Power Distribution & Terminal Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

329

P

o

wer Distrib

ution

& T

er

minal Blocks

Power Terminal Blocks

Series 11725

Specifications

Description:

Screw 

connection line side, (4) 0.250"
quick-connect load side power 
terminal block.

Poles:

2-, 3- or 4-poles.

Wire Range:

2 – 14 AWG

Cu/8 AWG Al.

Ratings:

Volts: — 600Vac/dc

Amps: — Up to 70A

SCCR:— 10kA per UL 508A table SB4.1

Agency Information:

CE, UL Guide XCFR2, E62622; 

CSA 47235.

Torque Rating:

45 lb-in max.

Catalog Numbers

Catalog
Numbers

Poles

11725-2

2

11725-3

3

11725-4

4

Series 11675

Specifications

Description:

Screw

connection line side, (3)
0.250" quick-connect
load side power 
terminal block.

Poles:

2- to 12-poles.

Wire Range:

8 – 14 AWG Cu.

Ratings:

Volts: — 250Vac/dc

Amps: — Up to 40A

SCCR:— 10kA per UL 508A table SB4.1

Agency Information:

CE, Guide XCFR2, UL E62622; 

CSA 47235.

Torque Rating:

9 lb-in max.

Catalog Numbers

Catalog

Catalog

Numbers

Poles

Numbers

Poles

11675-2

2

11675-8

8

11675-3

3

11675-9

9

11675-4

4

11675-10

10

11675-5

5

11675-11

11

11675-6

6

11675-12

12

11675-7

7

Data Sheets: 1117 (Series 160, 162, 165); 1148 (Series 163)

Series 160, 162, 163 
& 165

Specifications

Description:

Power 

terminal blocks.

Construction:

Molded black

thermoplastic.

Wire Range:

See Catalog

Numbers table.

Poles:

Series 160: 2-, 3- or 4-poles

Series 162, 163 and 165: 1-, 2- or 3-poles

Ratings:

Volts: — 600Vac/dc

Amps: — Up to 1520A

SCCR:— 10kA per UL 508A table SB4.1 (except for select

products noted in table)

Agency Information:

CE, Guide XCFR2, UL E62622

General Industrial Class per UL 1059; CSA Class 6228-01,
File 53787.

Flammability Rating:

UL 94V0.

Catalog Numbers

Connector

Catalog Line

Load

Material &

Agency

Numbers Connection

Connection Ampacity

Information

16021*

2/0-#14Cu, 2/0-#8Al

(6)#4-#14Cu, #4-#8Al

175A

UL/CSA

16023*

350kcmil-#6Cu/Al

(6)#4-#14Cu, #4-#12Al

310A

UL/CSA

16220**

2/0-#14Cu, 2/0-#8Al

(4)#4-#14Cu, #4-#8Al

175A

UL/CSA

16321**

2/0-#14Cu, 2/0-#8Al

(6)#4-#14Cu, #4-#8Al

175A

UL/CSA

16323**

350kcmil-#6Cu/Al

(6)#4-#14Cu, #4-#12Al

310A

UL/CSA

16325

(2)2/0-#14Cu, 2/0-#8Al

(6)#4-#14Cu, #4-#8Al

350A

UL/CSA

16330

500kcmil-#6Cu/Al

(6)#2-#14Cu, #2-#12Al

380A

UL/CSA

16332

350kcmil-#6Cu/Al

(3)#2-#14Cu, #2-#8Al

310A

UL/CSA

(2)1/0-#14Cu, 1/0-#8Al

16335

500kcmil-#6Cu/Al

(3)#2-#14Cu, #2-#8Al

380A

UL/CSA

(2)1/0-#14Cu, 1/0-#8Al

16370**

350kcmil-#6Cu/Al

(12)#4-#14Cu, #4-#12Al

310A

UL/CSA

16371**

350kcmil-#6Cu/Al

(6)#2-#14Cu, #2-#8Al

310A

UL/CSA

(3)1/0-#14Cu, 1/0-#8Al

16372

350kcmil-#6Cu/Al

(21)#10-#14Cu, #10Al

310A

UL/CSA

16373

350kcmil-#6Cu/Al

(3)1/0-#14Cu/Al

310A

UL/CSA

(14)#10-#14Cu, #10Al

16375

600kcmil-#2Cu/Al

(12)#4-#14Cu, #4-#12Al

420A

UL/CSA

16376

600kcmil-#2Cu/Al

(6)#2-#14Cu, #2-#8Al

420A

UL/CSA

(3)1/0-#14Cu, 1/0-#8Al

16377

(2)300kcmil-#4Cu/Al

(12)#4-#14Cu, #4-#12Al

570A

UL/CSA

16400

(4)500kcmil-#6Cu/Al

(22)#2-#14Cu/Al

1520A

UL/CSA

16528

(2)600kcmil-#2Cu/Al

(4)3/0-#6Cu/Al

840A

UL/CSA

(4)#4-#14Cu/Al

16530

(2)500kcmil-#6Cu/Al

(12)#4-#14Cu/Al

760A

UL/CSA

16541

(1)500kcmil-#6Cu/Al

(21)#6-#14Cu/Al

380A

UL/CSA

*160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165)
have mounting holes within barriers. See Data Sheet for dimensional drawings.
**SCCR up to 200kA

How To Order

Catalog Number + # of Poles

Example: 16021 – 3 (complete part number)

Optional Covers:

160 Series: CPB160 - (pole)
162 Series: CPB162 - (pole)
163 Series: CPDB- (pole)
165 Series: CPDB165 (1 for each pole)

Power Distribution & Terminal Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

330

Power Distribution & Terminal Blocks

Power Terminal Blocks: Stud & Splicer

Data Sheets: 1117 (Series 162, 165); 1148 (Series 163)

Series 162, 163 & 165

Specifications

Description:

Power stud 

terminal blocks.

Construction:

Molded black

thermoplastic.

Poles:

1-, 2- or 3-poles.

Wire Range:

See Catalog

Numbers table.

Ratings:

Volts: — 600Vac/dc

Amps: — Up to 760A

SCCR:— 10kA per UL 508A

table SB4.1 (except
where noted)

Agency Information:

CE,

Guide XCFR2, UL E62622
General Industrial Class per UL 1059; CSA Class 6228-01,
File 53787.

Flammability Rating:

UL 94V0.

Stud Block Catalog Numbers

Connector

Catalog

Line

Load

Material &

Agency

Numbers

Connection (Poles)

Connection (Poles)

Ampacity

Information

Connector to Stud

16280*

2/0-#14Cu-Al

1

4

-20 X 

3

4

Stud

Al-175A

UL

16281

2/0-#14Cu-Al

1

4

-20 Tapped hole

Al-175A

UL

16378

500kcmil-#6Cu-Al

(2)

1

4

-20 x 1 Stud

Al-380A

UL

CSA

16383

500kcmil-#6Cu-Al

(1)

3

8

-16 x 1 Stud

Al-380A

UL

CSA

16582

(2)500kcmil-#6Cu-Al

(2)

3

8

-16 x 1

5

8

Stud

Al-760A

UL

CSA

Stud to Stud

16290

1

4

-20 x 

3

4

Stud

1

4

-20 x 

3

4

Stud

Cu-175A

UL

16390

3

8

-16 x 1

1

8

Stud

3

8

-16 x 1

1

8

Stud

Cu-250A

UL

CSA

16394

1

2

-13 x 1

1

16

Stud

1

2

-13 x 1

1

16

Stud

Cu-400A

UL

CSA

16395

3

8

-16 x 1

7

16

Stud

(2)

1

4

-20 x 

9

16

Stud

Cu-310A

UL

CSA

16591

3

8

-16 x 1

7

16

Stud

(2)

3

8

-16 x 1

7

16

Stud

Cu-400A

UL

CSA

16593**

1

2

-13 X 1 Stud

1

2

-13 X 1 Stud

Cu-600A

UL

CSA

Nuts are not supplied with blocks
*SCCR up to 200kA
** 1-Pole not available

How To Order

Catalog Number + # of Poles

Example: 16000 – 3 (complete part number)

Optional Covers:

160 Series: CPB160 - (pole)
162 Series: CPB162 - (pole)
163 Series: CPDB - (pole)
165 Series: CPDB165 (1 for each pole) - new style

CPB165 - (pole) - old style

Series 160, 162,
163 & 165

Specifications

Description:

Power

splicer 
terminal blocks.

Construction:

Molded

black thermoplastic.

Wire Range:

See

Catalog Numbers table.

Poles:

Series 160: 2-, 3- or 4-poles

Series 162, 163 and 165: 1-, 2- or 3-poles

Ratings:

Volts: — 600Vac/dc

Amps: — Up to 760A

SCCR:— 10kA per UL 508A table SB4.1 (except for select

products noted in table)

Agency Information:

CE, Guide XCFR2, UL E62622

General Industrial Class per UL 1059; CSA Class 6228-01,
File 53787.

Flammability Rating:

UL 94V0.

Catalog Numbers

Connector

Catalog Line

Load

Material &

Agency

Numbers Connection

Connection Ampacity

Information

16000*

2/0-#8Cu/Al

2/0-#8Cu/Al

Al-175A

UL

16003*

250kcmil-#6Cu Only

250kcmil-#6Cu Only

Cu-255A

UL

16005*

350kcmil-#6Cu/Al

350kcmil-#6Cu/Al

Al-310A

UL

16200

#2-#14Cu, #2-#8Al

#2-#14Cu, #2-#8Al

Al-115A

UL

16201

1/0-#14Cu Only

1/0-#14Cu Only

Cu-150A

UL

16204**

2/0-#8Cu/Al

2/0-#8Cu/Al

Al-175A

UL

16301

250kcmil-#6Cu Only

250kcmil-#6Cu Only

Cu-255A

UL/CSA

16303

350kcmil-#6Cu/Al

350kcmil-#6Cu/Al

Al-310A

UL/CSA

16306

500kcmil-#6Cu/Al

500kcmil-#6Cu/Al

Al-380A

UL/CSA

16500

(2)350kcmil-#4Cu/Al

(2)350kcmil-#4Cu/Al

Al-620A

UL/CSA

16504

(2)500kcmil-#6Cu/Al

(2)500kcmil-#6Cu/Al

Al-760A

UL/CSA

*160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165)
have mounting holes within barriers. See Data Sheet for dimensional drawings.
**SCCR up to 200kA

How To Order

Catalog Number + # of Poles

Example: 16000 – 3 (complete part number)

Optional Covers:

160 Series: CPB160 - (pole)
162 Series: CPB162 - (pole)
163 Series: CPDB - (pole)
165 Series: CPDB165 (1 for each pole) - new style

CPB165 - (pole) - old style

Data Sheets: 1117 (Series 160, 162, 165); 1148 (Series 163)

For Short-circuit current rated stud power distribution
blocks, go to the Series PDB and Series 162 & 163
with high SCCR.

For Short-circuit current rated and/or finger-safe
splicer blocks, go to the Series PDBFS, Series PDB or
Series 162 & 163 with high SCCR.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

331

P

o

wer Distrib

ution

& T

er

minal Blocks

Series 14004

Specifications

Description:

Dead

front terminal block.

Poles:

2- to 12-poles.

Wire Range:

4 – 14 AWG Cu/
8 AWG Al.

Ratings:

Volts: — 600Vac/dc

Amps: — 90A

SCCR:— 10kA per UL 508A table SB4.1

Agency Information:

CE, Guide XCFR2, UL E62622; 

CSA 47235.

Marking:

Marking strip optional, consult factory.

Catalog Numbers

Catalog

Catalog

Numbers

Poles

Numbers

Poles

14004-2

2

14004-8

8

14004-3

3

14004-9

9

14004-4

4

14004-10

10

14004-5

5

14004-11

11

14004-6

6

14004-12

12

14004-7

7

Series 14002

Specifications

Description:

Barrier

terminal block.

Poles:

2- to 6-poles.

Wire Range:

2 – 14

AWG Cu/8 AWG Al.

Ratings:

Volts: — 600Vac/dc

Amps: — 115A

SCCR:— 10kA per 

UL 508A table SB4.1

Agency Information:

CE, Guide XCFR2, UL E62622; 

CSA 47235.

Torque Ratings*:

2-3, 50 lb-in; 4-6, 45 lb-in; 8, 40 lb-in; 

10-14, 35 lb-in.

*Consult factory for torque ratings for CP and Q options.

Marking:

Marking strip optional, consult factory.

Options For Load Side Connector

CP: Sems pressure plate, rated 60A, 600V

Q: Quick-Connect, rated 50A, 600V

To order options, enter letter code in front of Catalog
Number: i.e., CP14002-2.

Catalog Numbers

Catalog

Catalog

Numbers

Poles

Numbers

Poles

14002-2

2

14002-5

5

14002-3

3

14002-6

6

14002-4

4

Power Terminal Blocks: Barrier & Dead Front 

Power Distribution & Terminal Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

332

Ratings up to 200kA SCCR 
feature multiple bridging options 
for point of use configuration

DIN-Rail 
terminal blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

333

Connector

s

Connectors

Section Contents

Page

DIN-Rail Terminal Blocks

Feed through blocks (DS series) . . . . . . . . . . . . . . . . . . 334

Feed through blocks (DP series) . . . . . . . . . . . . . . 335-336

Mini feed through blocks (DM series) . . . . . . . . . . . . . . 337

Double level blocks (DDP series). . . . . . . . . . . . . . . . . . 338

Disconnect blocks (DG series) . . . . . . . . . . . . . . . . 339-340

Fuse holder blocks (F520 series) . . . . . . . . . . . . . . 341-342

Internally jumpered blocks (DDNS series) . . . . . . . . . . . 343

Test blocks (DTST2 series) . . . . . . . . . . . . . . . . . . . . . . 343

Panel mount blocks. . . . . . . . . . . . . . . . . . . . . . . . . 344-345
Short-Circuit Current Ratings (SCCRs) . . . . . . . . . 346-347

Accessories

Top screw-on bridges . . . . . . . . . . . . . . . . . . . . . . . . . . . 348

End brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349

Partition plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349

Jumper slides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350

Top insertion bridges . . . . . . . . . . . . . . . . . . . . . . . . . . . 350

Side insertion bridges . . . . . . . . . . . . . . . . . . . . . . . 351-352

Mounting rails and brackets . . . . . . . . . . . . . . . . . . . . . . 353

BussScribe Marking System

Marking system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354

Marking labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355-357

Compact Blocks

Feed through blocks (NDN series) . . . . . . . . . . . . . 358-359

Feed through blocks (C-Rail series) . . . . . . . . . . . . 360-361

Depluggable blocks . . . . . . . . . . . . . . . . . . . . . . . . . 362-363

Multi-pole panel mount blocks . . . . . . . . . . . . . . . . . . . . 364

Quick connect blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . 365

Double row terminal blocks

Series TB100 2- to 36-Pole blocks . . . . . . . . . . . . 366-367

Series TB200 & TB200HB 2- to 30-Pole blocks . .  368-369

Series TB300 & TB345 2- to 24-Pole blocks  . . . . 370-371

Marking options and covers for double row

series 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372

Top & bottom marking strips for terminal

blocks   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

373

Series TB400 2- to 12-Pole blocks . . . . . . . . . . . 374
Series KU 2- to 12-Pole Panel mount blocks . . . . 375 

Power feed through terminal blocks

Series C7021 1- to 6-Pole block . . . . . . . . . . . . . . . . . . 376

Series C7024 1- to 12-Pole block . . . . . . . . . . . . . . . . . 377

Scan this tag to get the

latest product information for the

New Family of Terminal blocks

and Accessories.

Scan this tag to get access to the 

Terminal Blocks

Cross Reference Search.

RED 

indicates

NEW 

information

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

334

Connectors

DS30

DS50

DS Series

The DS Series features a compact

design that saves wiring space 

on the control panel. Accessories 

include marking labels, partition 

plates as well as side and top 

insertion bridges. Designed for 

35mm DIN and 32mm G-Type rails.

IEC60947-7-1 & UL 1059 compliant.

DS20

End cover

Small partition

Top Insertion bridge 

Side Insertion bridge 

Top Screw-on bridge

Marking label

Mounting Rail

Tool

1

2

3

4

5

6

7

Block

Approval

Technical Data

UL

IEC

Rated voltage

600V

1000V

Rated current

20A

24A

Conductor cross section, 
flexible(AWG/mm

2

)

22~12 / 0.5~2.5

Conductor cross section, 
flexible(AWG/mm

2

)

22~12 / 0.5~2.5

Rated impulse 
withstand voltage

6kV

Torque(N•m)

0.4

Torque(lb-in)

3.5

Screw

M2.5

Wire strip length(mm)

9~11

WxHxD(mm)

5.1 x 39.6 x 40.5

Colors

Cat. No.

 

Grey

DS20-GY

 

Blue

DS20-BU

 Black

DS20-LK

 

Red

DS20-RD

 

Orange

DS20-OR

 Yellow

DS20-YW

 Green

DS20-GN

Accessories

Cat. No.

 

Grey

DS20-GY-ND

 

Blue

DS20-BU-ND

 Black

DS20-LK-ND

 

Red

DS20-RD-ND

 

Orange

DS20-OR-ND

 Yellow

DS20-YW-ND

 Green

DS20-GN-ND

DKNSPS-001

2-pole
3-pole
4-pole
10-pole

DSS2-5N-02P
DSS2-5N-03P
DSS2-5N-04P
DSS2-5N-10P

2-pole
3-pole
4-pole
10-pole

CSC-2-502PN
CSC-2-503PN
CSC-2-504PN
CSC-2-510PN

2-pole
3-pole
4-pole
10-pole 

N/A
N/A
N/A
N/A

TM26CB

DRL32MMG

DRL35MMHI

DRL35MMLO

Approval

Technical Data

UL

IEC

Rated voltage

600V

1000V

Rated current

30A

32A

Conductor cross section, 
flexible(AWG/mm

2

)

22~10 / 0.5~4

Conductor cross section, 
flexible(AWG/mm

2

)

22~10 / 0.5~4

Rated impulse 
withstand voltage

6kV

Torque(N•m)

0.6

Torque(lb-in)

5.3

Screw

M3

Wire strip length(mm)

9~11

WxHxD(mm)

6.1 x 39.6 x 40.3

Colors

Cat. No.

 

Grey

DS30-GY

 

Blue

DS30-BU

 Black

DS30-LK

 

Red

DS30-RD

 

Orange

DS30-OR

 Yellow

DS30-YW

 Green

DS30-GN

Accessories

Cat. No.

 

Grey

DS20-GY-ND

 

Blue

DS20-BU-ND

 Black

DS20-LK-ND

 

Red

DS20-RD-ND

 

Orange

DS20-OR-ND

 Yellow

DS20-YW-ND

 Green

DS20-GN-ND

DKNSPS-001

2-pole
3-pole
4-pole
10-pole

DSS4N-02P
DSS4N-03P
DSS4N-04P
DSS4N-10P

2-pole
3-pole
4-pole
10-pole

CSC-402PN
CSC-403PN
CSC-404PN
CSC-410PN

2-pole
3-pole
4-pole
10-pole

N/A
N/A
N/A
N/A

TM27CB

DRL32MMG

DRL35MMHI

DRL35MMLO

Approval

Technical Data

UL

IEC

Rated voltage

600V

1000V

Rated current

50A

41A

Conductor cross section, 
flexible(AWG/mm

2

)

22~10 / 0.5~4

Conductor cross section, 
flexible(AWG/mm

2

)

20~8 / 0.5~6

Rated impulse 
withstand voltage

8kV

Torque(N•m)

1.2

Torque(lb-in)

10.6

Screw

M4

Wire strip length(mm)

12~14

WxHxD(mm)

8 x 45 x 41.7

Colors

Cat. No.

 

Grey

DS50-GY

 

Blue

DS50-BU

 Black

DS50-LK

 

Red

DS50-RD

 

Orange

DS50-OR

 Yellow

DS50-YW

 Green

DS50-GN

Accessories

Cat. No.

 

Grey

DS50-GY-ND

 

Blue

DS50-BU-ND

 Black

DS50-LK-ND

 

Red

DS50-RD-ND

 

Orange

DS50-OR-ND

 Yellow

DS50-YW-ND

 Green

DS50-GN-ND

DKNSPS-002

2-pole
3-pole
4-pole
10-pole

DSS6N-02P
DSS6N-03P
DSS6N-04P
DSS6N-10P

2-pole
3-pole
4-pole
10-pole

CSC-602PN
CSC-603PN
CSC-604PN
CSC-610PN

2-pole
3-pole
4-pole
10-pole

N/A
N/A
N/A
N/A

TM28CB

DRL32MMG

DRL35MMHI

DRL35MMLO

Feed Through Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

335

Connector

s

Feed Through Blocks

DP25

DP35

DP45

DP Series

The DP Series features a generous

design allowing for more wiring 

space and access. Additionally, this 

series features a larger wire contact 

area and larger conducting elements.

Accessories include marking labels,

partition plates, side insertion bridge 

and top screw-on bridge for 

improved reliability. Comes with 

matching shaped grounding blocks. 

Designed for 35mm DIN and 32mm 

G-Type rails.

IEC60947-7 and UL1059 compliant.

Approval

  

Technical Data

UL

IEC

Rated voltage

600V

500V

Rated current

45A

41A

Conductor cross section, 
flexible(AWG/mm

2

)

20~8 / 0.5~6

Conductor cross section, 
flexible(AWG/mm

2

)

20~8 / 0.5~6

Rated impulse 
withstand voltage

8kV

Torque(N•m)

1.8

Torque(lb-in)

15.9

Screw

M4

Wire strip length(mm)

12~14

WxHxD(mm)

8 x 47.6 x 58.9

Colors

Cat. No.

 

Grey

DP45-GY

 

Blue

DP45-BU

 Black

DP45-LK

 

Red

DP45-RD

 

Orange

DP45-OR

 Yellow

DP45-YW

 Green

DP45-GN

Accessories

Cat. No.

 

Grey

DP25-GY-ND

 

Blue

DP25-BU-ND

 Black

DP25-LK-ND

 

Red

DP25-RD-ND

 

Orange

DP25-OR-ND

 Yellow

DP25-YW-ND

 Green

DP25-GN-ND

DKSPS-001

DKSPS-002

2-pole
3-pole
4-pole
10-pole

N/A
N/A
N/A
N/A

2-pole
3-pole
4-pole
10-pole

CSC-602P
CSC-603P
CSC-604P
CSC-610P

2-pole
3-pole
4-pole
10-pole

DS6-02P
DS6-03P
DS6-04P
DS6-10P

TM28CB

DRL32MMG

DRL35MMHI

DRL35MMLO

0.8 x 4mm

Approval

  

Technical Data

UL

IEC

Rated voltage

600V

630V

Rated current

25A

24A

Conductor cross section, 
flexible(AWG/mm

2

)

22~12 / 0.5~2.5

Conductor cross section, 
flexible(AWG/mm

2

)

22~12 / 0.5~2.5

Rated impulse 
withstand voltage

8kV

Torque(N•m)

0.8

Torque(lb-in)

7.1

Screw

M3

Wire strip length(mm)

10~12

WxHxD(mm)

5.1 x 47.6 x 58.9

Colors

Cat. No.

 

Grey

DP25-GY

 

Blue

DP25-BU

 Black

DP25-LK

 

Red

DP25-RD

 

Orange

DP25-OR

 Yellow

DP25-YW

 Green

DP25-GN

Accessories

Cat. No.

 

Grey

DP25-GY-ND

 

Blue

DP25-BU-ND

 Black

DP25-LK-ND

 

Red

DP25-RD-ND

 

Orange

DP25-OR-ND

 Yellow

DP25-YW-ND

 Green

DP25-GN-ND

DKSPS-001

DKSPS-002

2-pole
3-pole
4-pole
10-pole

N/A
N/A
N/A
N/A

2-pole
3-pole
4-pole
10-pole

CSC-2-502P
CSC-2-503P
CSC-2-504P
CSC-2-510P

2-pole
3-pole
4-pole
10-pole

DS2-5-02P
DS2-5-03P
DS2-5-04P
DS2-5-10P

TM26CB

DRL32MMG

DRL35MMHI

DRL35MMLO

0.4 x 2.5mm

Approval

  

Technical Data

UL

IEC

Rated voltage

600V

630V

Rated current

35A

32A

Conductor cross section, 
flexible(AWG/mm

2

)

22~10 / 0.5~4

Conductor cross section, 
flexible(AWG/mm

2

)

22~10 / 0.5~4

Rated impulse 
withstand voltage

8kV

Torque(N•m)

0.8

Torque(lb-in)

7.1

Screw

M3

Wire strip length(mm)

10~12

WxHxD(mm)

6.1 x 47.6 x 58.9

Colors

Cat. No.

 

Grey

DP35-GY

 

Blue

DP35-BU

 Black

DP35-LK

 

Red

DP35-RD

 

Orange

DP35-OR

 Yellow

DP35-YW

 Green

DP35-GN

Accessories

Cat. No.

 

Grey

DP25-GY-ND

 

Blue

DP25-BU-ND

 Black

DP25-LK-ND

 

Red

DP25-RD-ND

 

Orange

DP25-OR-ND

 Yellow

DP25-YW-ND

 Green

DP25-GN-ND

DKSPS-001

DKSPS-002

2-pole
3-pole
4-pole
10-pole

N/A
N/A
N/A
N/A

2-pole
3-pole
4-pole
10-pole

CSC-402P
CSC-303P
CSC-404P
CSC-410P

2-pole
3-pole
4-pole
10-pole

DS4-02P
DS4-03P
DS4-04P
DS4-10P

TM27CB

DRL32MMG

DRL35MMHI

DRL35MMLO

0.5 x 3mm

End cover

Partition

Small partition

Top Insertion bridge 

Side Insertion bridge 

Top Screw-on bridge

Marking label

Mounting Rail

Tool

1

2

3

4

5

6

7

Block

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

336

Connectors

Feed Through Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

337

Connector

s

Mini Feed Through Blocks

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

338

Connectors

Double Level Blocks

Disconnect Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

339

Connector

s

Grounding Blocks

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

340

Connectors

Grounding Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

341

Connector

s

Fuse Holder Blocks

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

342

Connectors

Fuse Holder Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

343

Connector

s

Connectors

Internally Jumpered Blocks

Test Blocks

DDNS10

DDNS Series

The DDNS10 is an internally 

jumpered terminal block. Internally 

jumpered double-level terminal 

blocks provide high-density power 

distribution in 3-in/1-out or 2-in/2-out 

or 1-in/3-out options with a single 

block. Add top and side insertion 

bridges to achieve any connection 

topology. IEC60947-7 and UL1059 

compliant.

Approval

  

Technical Data

UL

IEC

Rated voltage

300V

630V

Rated current

10A

17.5A

Conductor cross-
section, solid
(AWG/mm

2

)

22~14 / 0.5~1.5

Conductor cross-
section, flexible 
(AWG/mm

2

)

22~14 / 0.5~1.5

Rated impulse 
withstand voltage

8kV

Torque(N•m)

0.4

Torque(lb-in)

3.5

Screw

M2.5

Wire strip length(mm)

6~7

WxHxD(mm)

5.1 x 46.8 x 58.9

Colors

Cat. No.

 

Grey

DDNS10-GY

Accessories

Cat. No.

 

Grey

DDNS10-GY-ND

2-pole
3-pole
4-pole
10-pole

N/A
N/A
N/A
N/A

2-pole
3-pole
4-pole
10-pole

CSC-2-502P
CSC-2-503P
CSC-2-504P
CSC-2-510P

2-pole
3-pole
4-pole
10-pole

DS2-5-02P
DS2-5-03P
DS2-5-04P
DS2-5-10P

TM26CB

DRL32MMG

DRL35MMHI

DRL35MMLO

0.4 x 2.5mm

End cover

Partition

Small partition

Top Insertion bridge 

Side Insertion bridge 

Top Screw-on bridge

Marking label

Mounting Rail

Tool

1

2

3

4

5

6

7

Block

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

344

Connectors

Panel Mount Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

345

Connector

s

Panel Mount Blocks

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

346

Connectors

Short-Circuit Current Ratings (SCCRs)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

347

Connector

s

Short-Circuit Current Ratings (SCCRs)

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

348

Connectors

Accessories

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

349

Connector

s

Accessories

End Brackets

DKSPS-001

DKSPS-002

DKNSPS-002

DKSPS-006

Partition Plates

BRKT-NDSCRW3

BRKT-NDSCRW2

Use with 

DRL35MMHI

  

DRL35MMLO

Torque(N•m)   

0.78

Torque(lb-in)   

6.9

Screw  

M3

Dimensions - mm

BRKT-ND

BRKT-NDSCRW

Use with 

DRL35MMHI

  

DRL35MMLO

Torque(N•m)   

N/A

Torque(lb-in)   

N/A

Screw  

N/A

Dimensions - mm

Use with 

DRL35MMHI

  

DRL35MMLO

Torque(N•m)   

0.5

Torque(lb-in)   

4.4

Screw  

M3

Dimensions - mm

Use with 

DRL35MMHI

  

DRL35MMLO

Torque(N•m)   

1.8

Torque(lb-in)   

15.9

Screw  

M4

Dimensions - mm

Use with 

DP25 

DP35

 DP45 

DP60

 DIS10 

Use with 

DTST2

 

 

 

DKNSPS-001

Use with 

DS50

 

 

 

Use with 

DP25 

DP35

 DP45 

DP60

 

Use with 

DS20 

DS30

 

 

 

DKNSPS-003

Use with 

DP100

 

 

 

DKNSPS-004

Use with 

DP150

 

 

 

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

350

Connectors

Accessories

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

351

Connector

s

Accessories

CSC-2-5XXP

CSC-4XXP

CSC-6XXP

CSC-10XXP

CSC-16XXP

CSC-35XXP

Side Insertion Bridges

Use with 

DP25

  

DIS10 

P20S

  

DDNS10

Dimensions - mm

Use with 

DP35

  

DDP30

Dimensions - mm

Use with 

DTST2 

DP45

Dimensions - mm

Use with 

DP60 

  

Dimensions - mm

Poles (XX)    02, 03, 04, 10

Poles (XX)    02, 03, 04, 10

Poles (XX)    02, 03, 04, 10

Use with 

DP100

  

Poles (XX)    02, 03, 04, 10

Dimensions - mm

Use with 

DP150

  

Poles (XX)    02, 03, 04, 10

Dimensions - mm

CSC-2-5XXPN

Use with 

DS20

  

Poles (XX)    02, 03, 04, 10

Dimensions - mm

Poles (XX)    02, 03, 04, 10

CSC-95XXP

Use with 

DP230

  

Poles (XX)    02, 03, 04, 10

Dimensions - mm

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

352

Connectors

Accessories

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

353

Connector

s

Accessories

DRL35MMLO*

(35mm DIN-Rail - Low Profile)

DRL35MMHI* 

(35mm DIN-Rail - High Profile)

DRL15MM* 

(15mm DIN-Rail)

DRL32MMG*

(32mm G-Type)

BRKT-FLT 

(Flat Bracket)

BRKT-ANGL 

(Angle Bracket)

NFTA Series** 

(C-Rail)

NRA Series** 

(C-Rail)

Mounting Rails and Brackets

*Available in 1 meter lengths only.

**Cut to length. Consult Bussmann for details.

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

354

Connectors

BussScribe Marking System

Description

• Pen is installed manually

• USB interface to PC

• 110-240Vac power supply

• WINDOWS

®

 Operation System

Description

Support plate adjustable to accommodate various

sizes of marking labels. The support plate is 

universal and suitable for TM2xCB marking 

label series. 

Each plotter set includes one support plate, 

additional plates are available separately.

Description

Disposable black ink cartridge pen. 

Single pen per pack.

System Kit Includes:

• Plotter Pens

• Support Plate

• Software

• Plotter 

• Power Supplies

• USB Cable

DPLT-001SET

PLOTTER SET

PLOTTER PENS

DPLT-PEN 

(Tip 0.25mm) 

                   

DPLT-PEN2 

(Tip 0.35mm)

DPLT-SPLT 

SUPPORT PLATE

Marking Label Selection Chart

 

Part Number

DS50,
DP45, DP60, DP100, DP150, DP230, 
DG60, DG100, DG150, DG230, 
F520ST, F520STLED, F520DDST, 
DTST2

Length (mm)

Width (mm)

Line x Row

Number of Tags

Applicable Block Part Numbers

TM20CB

TM21CB

TM22CB

TM26CB

TM27CB

TM28CB

5.8

5.8

5.8

12

12

12

5.1

6.1

8.0

5.1

6.1

8.0

20 x 10

20 x 10

20 x 8

12 x 12

12 x 10

12 x 7

200

200

160

144

120

84

F20T0P,
DM20,
P20S, P25G, 2P25G

DDP30, 
DM30, 
P30S

DM50, 
P65S

DS20, 
DP25, 
DG25, 
DDNS10, 
DIS10

DS30, 
DP35, 
DG35

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

355

Marking Label Ordering Method (typical)

Connector

s

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

356

Connectors

Marking Label Ordering Method (typical)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

357

Marking Label Ordering Method (typical)

Connector

s

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

358

Connectors

NDN Series Feed Through Blocks

NDNV4

NDN3

NDN63

NDN Series

The NDN Series features a compact 

line of rail-mounted terminal blocks 

suitable for both 35mm DIN-Rail or 

C-Rail applications. Products easily 

snap onto the mounting rail for a 

quick, simple, low-cost solution. 

Available accessories include 

jumpers and marking tape.

UL E62622

CSA File 15364

CSA File 47235 (NDN1, NDN111)

Jumper

Approval

  

Technical Data

Rated voltage

600V

Rated Current

30A

Center spacing, in (mm)

0.25 / 6.35

Conductor cross-
section, flexible 
(AWG/mm

2

)

22~10 / 0.5~6

Number of Poles

4

Circuits per foot

48

Torque(N•m)

2

Torque(lb-in)

18

Screw

#6-32

WxHxD(mm)

25.4 x 34 x 42.4

Colors

Cat. No.

 

White (Standard)

NDNV4-WH

 

Black

NDNV4-BK

 

Yellow

NDNV4-YE

Accessories

Cat. No.

4 circuits

JN4

MTC6

35mm DIN-Rail 

C-Rail
C-Rail (low profile)

DRL35MML0

DRL35MMHI

NFTA Series

NRA Series

Dimensions - in (mm)    

Marking Tape

Mounting

Modular Option

Approval

  

Technical Data

Rated voltage

600V

Rated Current

30A

Center spacing, in (mm)

0.3 / 7.62

Conductor cross-
section, flexible 
(AWG/mm

2

)

22~10 / 0.5~6

Number of Poles

3

Circuits per foot

38

Torque(N•m)

2

Torque(lb-in)

18

Screw

#6-32

WxHxD(mm)

23.9 x 33.3 x 42.4

Colors

Cat. No.

 

White (Standard)

NDN3-WH

 

Black

NDN3-BK

 

Blue

NDN3-BL

 

Yellow

NDN3-YE

 

Red

NDN3-RE

Accessories

Cat. No.

2 circuits

JNDN3

MT12-1-2

35mm DIN-Rail

C-Rail
C-Rail (low profile)

DRL35MML0

DRL35MMHI

NFTA Series

NRA Series

Dimensions - in (mm)    

1.47

(37.33)

1.67

(42.41)

1.31

(33.27)

0.94

(23.87)

Approval

  

Technical Data

Rated voltage

600V

Rated Current

65A

Center spacing, in (mm)

0.375 / 9.52

Conductor cross-
section, flexible 
(AWG/mm

2

)

18~6 / 1~16

Number of Poles

3

Circuits per foot

30

Torque(N•m)

4

Torque(lb-in)

35

Screw

#10-32

WxHxD(mm)

29.7 x 36.8 x 42.4

Colors

Cat. No.

 

White (Standard)

NDN63-WH

 

Black

NDN63-BK

 

Yellow

NDN63-YE

Accessories

Cat. No.

2 circuits

JN3

MT12-1-2

35mm DIN-Rail 

C-Rail
C-Rail (low profile)

DRL35MML0

DRL35MMHI

NFTA Series

NRA Series

Dimensions - in (mm)    

1.50

(38.10)

1.67

(42.41)

1.45

(36.83)

1.17

(29.71)

1.23

(31.24)

1.47

(37.33)

1.67

(42.41)

1.00

(25.40)

Marking

Tape

1.34

(34.04)

Block

N/A 

N/A 

N/A 

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

359

Connector

s

NDN Series Feed Through Blocks

NDN1

NDN111

Approval

  

Technical Data

Rated voltage

600V

Rated Current

90A

Center spacing in (mm)

0.635 / 16.31

Conductor cross-
section, flexible 
(AWG/mm

2

)

18~2 / 1~35

Number of Poles

3

Circuits per foot

18

Torque(N•m)

3.6

Torque(lb-in)

32

Screw

1/4-28

WxHxD(mm)

47.5 x 36.6 x 43.5

Colors

Cat. No.

 

White (Standard)

NDN111-WH

 

Black

NDN111-BK

 

Blue

NDN111-BL

 

Yellow

NDN111-YE

 

Red

NDN111-RE

Accessories

Cat. No.

2 circuits

JN1

MT12-1-2

35mm DIN-Rail

C-Rail
C-Rail (low profile)

DRL35MML0

DRL35MMHI

NFTA Series

NRA Series

Dimensions - in (mm)    

NDN111A-WH, NDN111A-BK, NDN111A-YE

0.62

(15.75)

1.71

(43.48)

1.46

(37.13)

Mtg. holes

0.18 (4.57) dia.

0.28 (7.11) c'bores

Dovetail

Option

1.87

(47.50)

1.44

(36.57)

0.59

(14.99)

Dovetail

Option

1.43

(36.31)

1.71

(43.48)

1.32

(33.68)

Approval

  

Technical Data

Rated voltage

600V

Rated Current

90A

Center spacing in (mm)

0.635 / 16.31

Conductor cross-
section, flexible 
(AWG/mm

2

)

18~2 / 1~35

Number of Poles

1

Circuits per foot

18

Torque(N•m)

3.6

Torque(lb-in)

32

Screw

1/4-28

WxHxD(mm)

15 x 30.3 x 43.5

Colors

Cat. No.

 

White (Standard)

NDN1-WH

Accessories

Cat. No.

MT12-1-2

35mm DIN-Rail 

C-Rail
C-Rail (low profile)

DRL35MML0

DRL35MMHI

NFTA Series

NRA Series

Dimensions - in (mm)    

NDN1A-WH 

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

360

Connectors

C-Rail Feed Through Blocks

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

361

Connector

s

C-Rail Feed Through Blocks

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

362

Connectors

Depluggable Blocks

15188

15288

PLU3

Depluggable Blocks

Depluggable terminal blocks are 

available for both 35mm DIN-Rail 

and C-Rail applications.  These 

blocks provide a simple 

depluggable* option for panel wiring 

applications with the convenience 

of quick, easy, snap-on installation.  

Product accessories, such as 

jumpers and marking tape, are 

available for most products.

UL E62622

CSA File 15364

CSA File 47235 (15188 Series)

*Not for use as a load break

 disconnect.

Approval

  

Technical Data

Rated voltage

600V

Rated Current

30A

Center spacing in (mm)

0.375 / 9.52

Conductor cross-
section, flexible 
(AWG/mm

2

)

16~12 / 1.5~4

Number of Poles

3 or 4

Circuits per foot

32

Torque(N•m)

1.4

Torque(lb-in)

12

Screw

#6-32

WxHxD(mm)
3-Pole
4-Pole

30.2 x 49.3 x 47.8
39.2 x 49.3 x 47.8

Colors

Cat. No.

 

White (Standard)

15188-3

 

White (Standard)

15188-4

Accessories

Cat. No.

2 circuits

15188J-2-J

35mm DIN-Rail

DRL35MMLO

DRL35MMHI

Reverse Wiring
Locking
Reverse; Locking

15188-_R
15188-_S

15188-_RS

Dimensions - in (mm)    

Options offered for both pole lengths

1.94

(49.27)

3 Pole = 1.19 (30.22)

4 Pole = 1.56 (39.62)

1.94 

(49.27) 

0.375 
(9.52) 

0.22 

(5.58) 

3 Pole = 1.19 (30.22) 

4 Pole = 1.56 (39.62) 

In-Line Wiring Direction

Reverse Wiring Direction

Approval

  

Technical Data

Rated voltage

600V

Rated Current

65A

Center spacing in (mm)

0.54 / 13.7

Conductor cross-
section, flexible 
(AWG/mm

2

)

16~6 / 1.5~16

Number of Poles

3

Circuits per foot

22

Torque(N•m)

2.3

Torque(lb-in)

20

Screw

#8-32

WxHxD(mm)

43.2 x 49.3 x 47.9

N/A

Colors

Cat. No.

 

White (Standard)

15288

Accessories

Cat. No.

35mm DIN-Rail

DRL35MMLO

DRL35MMHI

Reverse Wiring
Screw Together
Locking

15288-R

15288-ST

15288-S

Dimensions - in (mm)    

Options may be combined

1.94 

(49.27) 

0.54 

(13.7) 

2.30 

(58.4) 

for ST option 

1.70 

(43.2) 

1.94 

(49.27)

1.70 

(43.2) 

Reverse Wiring Direction

In-Line Wiring Direction

Approval

  

Technical Data

Rated voltage

600V

Rated Current

40A

Center spacing in (mm)

0.39 / 9.91

Conductor cross-
section, flexible 
(AWG/mm

2

)

22~8 / 0.5~10

Number of Poles

3

Circuits per foot

28

Torque(N•m)

2

Torque(lb-in)

18

Screw

#8-32

WxHxD(mm)

31.8 x 47.0 x 45.6

N/A

Colors

Cat. No.

 

White (Standard)

PLU3-WH

 

Black

PLU3-BK

 

Yellow

PLU3-YE

Accessories

Cat. No.

2 circuits

JN3

MT12-1-2

C-Rail (AL)
C-Rail (low profile)

NFTA Series

NRA Series

Dimensions - in (mm)    

1.25 

(31.75) 

0.59 

(14.98) 

1.79 

(45.64)

1.85 

(46.99) 

1.25 

(31.75) 

1.25 

(31.75) 

Jumper

Marking Tape

Mounting

Configurable Option

Block

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

363

Connector

s

Depluggable Blocks

PLU1

Approval

  

Technical Data

Rated voltage

600V

Rated Current

70A

Center spacing in (mm)

0.625 / 15.88

Conductor cross-
section, flexible 
(AWG/mm

2

)

18~4 / 1.0~25

Number of Poles

1 - 3

Circuits per foot

19

Torque(N•m)

3.6

Torque(lb-in)

32

Screw

1/4 - 28

WxHxD(mm)
1-Pole
2-Pole
3-Pole

18.5 x 47.0 x 45.6
34.0 x 47.0 x 45.6
49.5 x 47.0 x 45.6

Colors

Cat. No.

 

White (1-Pole)

PLU1-WH

 

White (2-Pole)

PLU11-WH

 

White (3-Pole)

PLU111-WH

Accessories

Cat. No.

2 circuits

JN1

MT12-1-2

C-Rail (AL)
C-Rail (low profile)

NFTA Series

NRA Series

Dimensions - in (mm)    

PSU1

Approval

  

Technical Data

Rated voltage

600V

Rated Current

45A

Center spacing in (mm)

0.625 / 15.88

Conductor cross-
section, flexible 
(AWG/mm

2

)

Ring Terminals 

Only

Number of Poles

1 - 3

Circuits per foot

19

Torque(N•m)

2.7

Torque(lb-in)

24

Screw

#10-32

WxHxD(mm)
1-Pole
2-Pole
3-Pole

18.5 x 49.1 x 62.1
34.4 x 49.1 x 62.1
50.3 x 49.1 x 62.1

Colors

Cat. No.

 

White (1-Pole)

PSU1-WH

 

White (2-Pole)

PSU11-WH

 

White (3-Pole)

PSU111-WH

Accessories

Cat. No.

 

MT12-1-2

C-Rail (AL)
C-Rail (low profile)

NFTA Series

NRA Series

Dimensions - in (mm)    

1.87 

(47.49) 

1.85 

(46.99) 

1.48 

(37.59) 

1.25 

(31.75) 

0.625

(15.88)

1.93 

(49.12) 

2.44 

(62.10) 

1.48 

(37.64) 

1.30 

(33.00) 

0.43 

(11.10) 

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

364

Connectors

Multi-Pole Panel Mount Blocks

KT3

KT4

PLK3

Panel Mount Blocks

Multi-pole panel mount terminal 

blocks provide a compact, high 

density circuit connection solution 

without the necessity of a mounting 

rail.  These products are designed to 

be nested together to form one string 

of circuit connections. 

UL E62622

CSA 15364 (excluding PLK3)

Approval

  

Technical Data

Rated voltage

600V

Rated Current

40A

Center spacing in (mm)

0.39 / 9.91

Conductor cross-
section, flexible 
(AWG/mm

2

)

22~8 / 0.5~10 

Number of Poles

3

Circuits per foot

28

Torque(N•m)

2

Torque(lb-in)

18

Screw

#8-32

WxHxD(mm)

59.5 x 31.8 x 31.0

Colors

Cat. No.

 

White (Standard)

KT3-WH

 

Black

KT3-BK

 

Red

KT3-RE

Accessories

Cat. No.

2 circuits

JN3

MT12-1-2

Mounting Foot 

KAD

Dimensions - in (mm)     

#8 screw clearance 

KAD 

end mtg. 

adapter 

1.22 

(31.04) 

1.25 

(31.75) 

2.34 

(59.51) 

1.25 

(31.75) 

0.25 

(6.35) 

1.25 

(31.75) 

1.87 

(47.63) 

Approval

  

Technical Data

Rated voltage

600V

Rated Current

30A

Center spacing in (mm)

0.25 / 6.35

Conductor cross-
section, flexible 
(AWG/mm

2

)

22~10 / 0.5~6 

Number of Poles

4

Circuits per foot

48

Torque(N•m)

2

Torque(lb-in)

18

Screw

#6-32

WxHxD(mm)

43.8 x 34.0 x 32.2

Colors

Cat. No.

 

White*

KT4-WH-A

 

White*

KT4-WH-B

 

Black

KT4-BK

Accessories

Cat. No.

4 circuits

JN4

MTC6

Dimensions - in (mm)     

1.34 

(34.04) 

1.26 

(32.23) 

0.62 

(15.88) 

0.98 

(24.99) 

0.37 

(9.40) 

Approval

  

Technical Data

Rated voltage

600V

Rated Current

40A

Center spacing in (mm)

0.39 / 9.91

Conductor cross-
section, flexible 
(AWG/mm

2

)

22~8 / 0.5~10 

Number of Poles

3

Circuits per foot

28

Torque(N•m)

2

Torque(lb-in)

18

Screw

#8-32

WxHxD(mm)

65.7 x 46.9 x 45.5

Colors

Cat. No.

 

White (Standard)

PLK3-WH

Accessories

Cat. No.

2 circuits

JN3

MT12-1-2

Mounting Foot 

KAD

Dimensions - in (mm)     

1.46 

(37.22) 

0.56 

(14.22) 

1.79 

(45.52)

1.84 

(46.86) 

Jumper

Marking Tape

Mounting

Block

*The KT4 products are designed to be nested
  together to form one string of circuit 
  connections. When used in series, order 

t

b

KT4 WH A

d KT4 WH B

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

365

Connector

s

Quick Connect Blocks

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Catalog Number Build-A-Code

Series

Poles

Screw Options

Marking/Cover

Hardware Options

TB100

For more information, visit www.cooperbussmann.com/DatasheetsEle

366

Connectors

Double Row Terminal Blocks

0.14
(3.5)

0.375

(9.5)

0.30
(7.6)

0.17 dia.

(4.3)

0.14
(3.5)

0.88

(22.3)

0.41

(10.4)

0.31 (7.9)

A

B

0.25 (6.3)

TB100- in (mm)

Series TB100

Specifications

Rating

:  30A, 300V*

Center Spacing

:  0.375˝ or 3/8˝ (9.52mm)

Wire Range

:  #14 - 22 AWG Cu

Screw Size

:  #6-32 philslot screws

Torque Rating

:  9 lb-in

Distance Between Barriers

:  0.30˝  (7.62mm)

Mounting

:  #6 screws

Operating Temperature

:  130°C (266°F) max., 

-40°C (-40°F) min.

Materials

:  Molded base: Black, UL rated 94V0 

thermoplastic

Terminal plating: Tin over brass;  Screws: Zinc-plated steel 

Breakdown Voltage

:  3600V 

Agency Information

:  UL File E62622/CSA File 47235; IEC

Compliance; CE Certified

* Max rating shown; some options may be rated lower.

Dimensions - in

Poles A

B

Poles A

B

Poles

A

B

02

1.40

1.12

14

5.90

5.62

26

10.40

10.12

03

1.78

1.50

15

6.28

6.00

27

10.78

10.50

04

2.16

1.88

16

6.66

6.38

28

11.16

10.88

05

2.53

2.25

17

7.03

6.75

29

11.53

11.25

06

2.90

2.62

18

7.40

7.12

30

11.90

11.62

07

3.28

3.00

19

7.78

7.50

31

12.28

12.00

08

3.66

3.38

20

8.16

7.88

32

12.66

12.38

09

4.03

3.75

21

8.53

8.25

33

13.03

12.75

10

4.40

4.12

22

8.90

8.62

34

13.40

13.12

11

4.78

4.50

23

9.28

9.00

35

13.78

13.50

12

5.16

4.88

24

9.66

9.38

36

14.16

13.88

13

5.53

5.25

25

10.03

9.75

1” = 25.4mm.

TB100-08

TB100-04SP

02

to 

36

Blank -  steel philslot, zinc-plated

L1

to 

L6

QC1

to 

QC20 

- quick connects

00   

-  screws shipped bulk

Marking Options (See page 318)

B   

-  brass philslot, nickel-plated

Marker Strips (See page 319)

SP

-  steel Sems philslot, zinc-plated

Special Markings (See page 319)

Custom Options**

Covers (See page 318)

J101 

- flat slip-on jumper

(2 position only)

0J2 

- over barrier jumpers

0J4 

- over barrier jumpers

**

Contact factory for pole configuration.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

367

Connector

s

Double Row Terminal Blocks

Hardware Options

Quick Connects – Assembled:

Terminals 0.187” x 0.020”. Maximum current rating 13 amps. For other orientations, contact Bussmann.

QC1

QC2

QC3

QC4

QC5

QC6

QC7

QC8

QC9

QC10

QC11

QC12

QC13

QC14

QC15

QC16

QC17

QC18

QC19

QC20

Quick Connects – Bulk:

minimum order per part number – 100 pieces.

QC101-J

QC102-J

QC103-J

Flat – none

QC 45° – none

QC 90° – none

QC104-J

QC105-J

QC106-J

QC107-J

QC108-J

QC109-J

Flat – Flat

Flat – QC 45°

Flat – QC 90°QC 45° – QC 45° QC 45° – QC 90°QC 90° – QC 90°

Jumpers – Bulk:

minimum order per part number – 100 pieces. Contact Bussmann for jumper assembly.

J101

OJ2

OJ4

Flat slip-on

Slip-on over barrier

Closed over barrier

(Bulk: J101-J)

(Bulk: OJ2-J)

(Bulk: OJ4-J)

Screw Options

B

Brass Philslot

Nickel-Plated

SP

Steel SEMS

Philslot Zinc-Plated

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

0.16 
(4.0) 

0.437 
(11.1) 

0.353 

(8.9) 

0.17 dia. 

(4.3) 

0.16 
(4.0) 

1.12 

(28.4) 

0.56 

(14.2) 

0.44 (11.2) 

0.31 (7.8)

For more information, visit www.cooperbussmann.com/DatasheetsEle

368

Connectors

Double Row Terminal Blocks

Series TB200 & TB200HB

Specifications
Ratings:

Volts: — 300V* (TB200)

— 600V* (TB200HB)

Amps: — 30A*

Center Spacing

:  0.437˝ or 7/16˝ (11.10mm)

Wire Range

:  #12 - 22 AWG Cu

Screw Size

:  #6-32 philslot screws

Torque Rating

:  9 lb-in

Distance Between Barriers

:  0.353˝  (8.97mm)

Mounting

:  #6 screws

Operating Temperature

:  130°C (266°F) max., 

-40°C (-40°F) min.

Materials

:  Molded base: Black, UL rated 94V0 

thermoplastic

Terminal plating: Tin over brass;  Screws: Zinc-plated steel 

Breakdown Voltage

:  4800V

Agency Information

:  UL File E62622, CSA File 47235 &

15364; IEC Compliance; CE Certified

* Max rating shown; some options may be rated lower.

Dimensions - in

Poles

A

B

Poles

A

B

Poles A

B

02

1.63

1.31

12

6.00

5.68

22

10.37

10.06

03

2.07

1.75

13

6.44

6.12

23

10.81

10.50

04

2.51

2.18

14

6.87

6.56

24

11.25

10.93

05

2.94

2.62

15

7.31

7.00

25

11.68

11.37

06

3.38

3.06

16

7.75

7.43

26

12.12

11.81

07

3.82

3.50

17

8.19

7.87

27

12.56

12.25

08

4.25

3.93

18

8.62

8.31

28

13.00

12.68

09

4.69

4.37

19

9.06

8.75

29

13.44

13.12

10

5.13

4.81

20

9.50

9.18

30

13.87

13.56

11

5.57

5.25

21

9.94

9.62

1” = 25.4mm.

TB200 - in (mm)

TB200HB

TB200-10SP

TB200HB-06

0.16
(4.0)

0.437
(11.1)

0.353

(8.9)

0.17 dia.

(4.3)

0.17 x 0.22 slots

(4.3 x 5.6)

0.16
(4.0)

1.37

(34.8)

0.90

(22.8)

0.75

(19.0)

0.44 (11.2)

A

B

0.33 (8.4)

Catalog Number Build-A-Code

Series

Poles

Screw Options

Marking/Cover

Hardware Options

TB

200

-  Standard

02

to 

30

Blank -  Steel philslot, zinc-plated

L1

to 

L6 

- Marking Options (See page 318)

QC1

to 

QC20 

- Quick connects

200HB

-  High barrier

00 

-  Screws shipped bulk

Special Markings (See page 318)

B  

-  Brass philslot, nickel-plated

Covers (See page 318)

BS   

-  Brass Sems philslot, nickel-plated

Marking Strips (See page 319)

Custom Options**

SP   

-  Steel Sems philslot, zinc-plated

J201 

- Flat slip-on jumper

P  

-  Steel Sems (P-style)

(2 position only)

ST

-  Stainless steel, philslot

0J3 

- Over barrier jumpers

SS

-  Stainless steel Sems, philslot

0J5 

- Over barrier jumpers

0J7 

- Over barrier jumpers

**

Contact factory for pole configuration

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

369

Connector

s

Double Row Terminal Blocks

Screw Options

B

BS

SP

P

ST

SS

Brass Philslot

Brass SEMS

Steel SEMS

Steel SEMS

Stainless Steel

Stainless Steel

Nickel-Plated

Philslot Nickel-Plated

Philslot Zinc-Plated

(P-Style)

Philslot

SEMS Philslot

B001-7016-J

B001-7019-J

B001-7007-J

B001-7000-J

F507-J

B001-7085-J

Hardware Options

Quick Connects – Assembled:

Terminals 0.25” x 0.031”. Maximum current rating 20 amps. For other orientations, contact Bussmann.

QC1

QC2

QC3

QC4

QC5

QC6

QC7

QC8

QC9

QC11

QC10

QC12

QC13

QC14

QC15

QC16

QC17

QC18

QC19

QC20

Quick Connects – Bulk:

minimum order per part no. – 100 pieces.

QC201-J

QC202-J

QC203-J

QC 45° – blank

Flat – blank

QC 90° – blank

QC204-J

QC205-J

QC206-J

QC207-J

QC208-J

QC209-J

Flat – Flat

Flat – QC 45°

Flat – QC 90°

QC 45° – QC 45°

QC 45° – QC 90° QC 90° – QC 90°

Jumpers – Bulk:

minimum. order per part no. – 100 pieces. Contact Bussmann for jumper assembly.

J201

OJ3

OJ5

OJ7

Flat slip-on

Slip-on over

Closed over

Closed over

(not available on TB200HB)

barrier for TB200HB

barrier for TB200HB

barrier for TB200

(Bulk: J201-J)

(Bulk: OJ3-J)

(Bulk: OJ5-J)

(Bulk: OJ7-J)

Bulk:

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Catalog Number Build-A-Code

Series

Poles

Screw Options

Marking/Cover

Hardware Options

TB

300

= 8-32 screw

02

to 

24

Blank

= Steel philslot, zinc-plated

L1

to 

L6

Marking Options (pg 318)

QC1

to 

QC20

= Quick connects (TB300 only)

345

= 10-32 screw

00

=       Screws shipped bulk

Special Markings (pg 318)

B

=        Brass philslot, nickel-plated

Covers (pg 318)

BS

=      Brass Sems philslot, 

Marking Strips (pg 319)

nickel-plated (TB300 only)

SP

=      Steel Sems philslot, zinc-plated

(TB300 only)

ST

=      Stainless steel, philslot

Custom Options
J301

= Flat slip-on jumper

OJ6

= Over barrier jumper

OJ11

= Over barrier jumper

For more information, visit www.cooperbussmann.com/DatasheetsEle

370

Connectors

Double Row Terminal Blocks

0.22 
(5.6) 

0.56 

(14.2) 

0.56 

(14.2) 

0.412 
(10.4) 

0.21dia.

(5.3)

0.21 x 0.25 slots 

(5.3 x 6.3) 

1.33 

(33.8) 

0.90 

(22.8) 

0.81 

(20.5) 

0.50 (12.7) 

 8-32 binding head screw - TB 300 
10-32 binding head screw - TB 345 

0.33 (8.4) 

 

TB300 & TB345 - in (mm)

Series TB300 & TB345

Specifications
Ratings:

Volts: — 600V*

Amps: — 30A* (TB300)

— 45A (TB345)

Center Spacing

:  0.562” or 9/16” (14.28mm)

Wire Range

:  #8 - 22 AWG Cu

Screw Size

: TB300 –  #8-32 philslot screws

TB345 –  #10-32 philslot screws

Torque Rating

:  #8 screws - 16 lb-in; 

#10 screws - 20 lb-in

Distance Between Barriers

:  0.41”  (10.5mm)

Mounting

:  TB300 – #8 screws;  TB345 – #10 screws

Operating Temperature

:  130°C (266°F) max., -40°C (-40°F)

min.

Material

:  Molded base: Black, UL rated 94V0 thermoplastic

Terminal plating: Tin over brass;  Screws: Zinc-plated steel 

Breakdown Voltage

:  7500V

Agency Information

:  UL File E62622, CSA File 47235; IEC

Compliance; CE Certified

* Max rating shown; some options may be rated lower.

Dimensions - in

Poles

A

B

Poles

A

B

Poles

A

B

02

2.13

1.69

10

6.62

6.19

18

11.12

10.68

03

2.69

2.25

11

7.18

6.75

19

11.68

11.25

04

3.25

2.81

12

7.75

7.31

20

12.24

11.81

05

3.81

3.37

13

8.31

7.87

21

12.80

12.37

06

4.37

3.94

14

8.87

8.44

22

13.37

12.93

07

4.94

4.50

15

9.43

9.00

23

13.93

13.50

08

5.50

5.06

16

9.99

9.56

24

14.49

14.06

09

6.06

5.62

17

10.56

10.12

1” = 25.4mm.

TB300-08

TB345-06SP

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

371

Connector

s

Double Row Terminal Blocks

Screw Options

B

BS

SP

ST

Brass Philslot

Brass SEMS

Steel SEMS

Stainless Steel

Nickel-Plated

Philslot Nickel-Plated

Philslot Zinc-Plated

Philslot

TB300 Blk:

B001-7018-J

B001-7015-J

B001-7017-J

B001-7063-J

TB345 Blk:

B500-023-028-J

B001-7064-J

Hardware Options

Quick Connects – Assembled:

TB300 only. Terminals 0.25” x 0.031”. Maximum current rating 20 amps. For other orientations, contact Bussmann.

QC1

QC2

QC3

QC4

QC5

QC6

QC7

QC8

QC9

QC10

QC11

QC12

QC13

QC14

QC15

QC16

QC17

QC18

QC19

QC20

Quick Connects – Bulk:

(*TB300 only) minimum order per part number. – 100 pieces.

QC201-J

QC202-J

QC203-J

Flat – blank

QC 45° – blank

QC 90° – blank

QC204-J

QC205-J

QC206-J

QC207-J

QC208-J

QC209-J

Flat – Flat

Flat – QC 45°

Flat – QC 90°

QC 45° – QC 45° QC 45° – QC 90°

QC 90° – QC 90°

Jumpers – Bulk:

minimum order per part number – 100 pieces. Contact Bussmann for jumper assembly.

J301

OJ6

OJ11

Flat slip-on(TB300 only)

Closed over barrier

Slip-on over barrier

(Bulk: J301-J)

(Bulk: OJ6-J)

(Bulk: OJ11-J)

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Catalog Number Build-A-Code

For more information, visit www.cooperbussmann.com/DatasheetsEle

372

Connectors

Marking Options and Covers for Double Row 
Terminal Blocks

Standard Marking

Standard markings are applied directly to the side(s) of a
block. The standard marking color is white. The standard
numeral height is 0.125 inches (3.17mm).

Note: Blocks marked on both sides require a different code
for each side. Example: Style L1 on one side of the block
requires Style L2 on the other side to ensure common 
terminal marking. To order, add appropriate suffix (L1, L2, L3,
L4, L5 and/or L6) to block catalog number in the proper
sequence.

Special Marking

Special markings are available at an additional charge
Drawing(s) must be submitted to ensure accuracy of part
required. Consult Bussmann for price and delivery.

Note: Marking is not available on TB400 Series

Covers

Covers prevent personnel, screws and foreign items from
contacting live terminals, and are available in white or clear
plastic. Two cover clips are supplied with each cover. The
cover width is 1.31 inches (33.3mm).

All covers must be ordered separately.

Example: 10 position cover, white, TB100 Series = Catalog
Number 

X12010

.

1   2   3

3   2   1

3   2   1

1   2   3

1

2

3

1

2

3

L1

L2

L3

L4

L5

L6

K

3

4

5

G

3AC

MAS

TER

300V
MAX

20A

INPUT

OUT
PUT

134

134

GND

MB

RED
BLK
BLU

A

M

Series

Cover Strip

Poles

High Barrier Option Only

X

120

-  TB100/white

02

to 

36

(TB100)

HB

= High Barrier

119

-  TB100/clear

02

to 

30

(TB200/TB200HB)

220

-  TB200/TB200HB - white

02

to 

24

(TB300/TB345)

219

-  TB200/TB200HB - clear

320

-  TB300 & TB345 - white

319

-  TB300 & TB345 - clear

Cover Clips – Bulk

Part Number

DD1-J

– TB100 Series

DD2-J

– TB200 Series

DD2HB-J

– TB200HB Series

DD3-J

– TB300 Series

Note: Covers are not available on TB400 Series.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

373

Top & Bottom Marking Strips for Double Row 
Terminal Blocks

Top Marker Strips

Top mounting marker strips are available in white (opaque)
plastic. Two cover clips are supplied with each marker strip.

All top marker strips must be ordered separately.

Example: 12 position cover, TB200, 0.032” x 0.312” =
Catalog Number 

X20312

.

Example: 12 position cover, TB200HB, 0.06” x 0.50” =
Catalog Number 

X23312HB

.

Bottom Marker Strips

Bottom mounting marker strips are made of black PVC,
0.030” thick. Space is available to handle most marking 
situations. All marker strips must be ordered separately.

To order, specify part number and required marking 
orientation: (BF) bottom forward, (BR) bottom reverse, (TF)
top forward, or (TR) top reverse. Consult factory for specials.

Example: 13 position strip, TB100 with no markings, space
for marking one side = Catalog Number 

X10513

.

Standard numeral height is 0.125”. Standard markings are 
0-99. Special markings are available on special order.
Drawing(s) must be submitted to ensure accuracy of part
required.

Dimensions (in)

Dim.

TB100

TB200

TB200HB TB300

TB345

TB400

A

1.13

1.37

1.62

1.58

1.58

N/A

B

1.38

1.62

1.81

1.81

1.81

N/A

Connector

s

Space for marking one side

Space for marking two sides

Catalog Number Build-A-Code

Series

Top Marker Strip

Poles

High Barrier Option Only

X

133

- TB100 (0.060 thk x 0.500 w)

02

to 

36

(TB100)

HB

= High Barrier

103

- TB100 (0.032 thk x 0.312 w)

02

to 

30

(TB200/TB200HB)

233

- TB200/TB200HB (0.060 thk x 0.500 w)

02

to 

24

(TB300/TB345)

203

- TB200/TB200HB (0.032 thk x 0.312 w)

333

- TB300 & TB345 (0.060 thk x 0.500 w)

303

- TB300 & TB345 (0.032 thk x 0.380 w)

Note: Marking Strips are not available on TB400 Series

Catalog Number Build-A-Code

Series

Bottom Marker Strip

Poles

Orientation

X

105

= TB100/marking one side

02

to 

36

(TB100)

BF

= Bottom forward

101

= TB100/marking both sides

02

to 

30

(TB200/TB200HB)

BR

= Bottom reverse

205

= TB200/marking one side

02

to 

24

(TB300/TB345)

TF

= Top forward

201

= TB200/marking both sides

TR

= Top reverse

295

= TB200HB/marking one side

291

= TB200HB/marking both sides

305

= TB300 & TB345/marking one side

301

= TB300 & TB345/marking both sides

Note: Marking Strips are not available on TB400 Series.

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

374

Connectors

Screw Options

B

ST

Brass Philslot

Stainless Steel

Nickel-Plated

Philslot

Bulk: B500-023-028-J

B001-7064-J

Hardware Options

OJ14: Closed over barrier

(Bulk:OJ14-J)

Double Row Terminal Blocks

Series TB400

Specifications
Ratings:

Volts: — 600V

Amps: — 75A

Center Spacing

:  0.687˝ or 11/16˝ (17.45mm)

Wire Range

:  #6-14 AWG Cu

Screw Size

:  #10-32 philslot screws

Torque Rating

:  20 lb-in

Distance Between Barriers

:  0.56˝  (14.3mm)

Mounting

:  #10 screws

Operating Temperature

:  130°C (266°F) max., 

-40°C (-40°F) min.

Material

:  Molded base: Black, UL rated 94V0 thermoplastic

Terminal plating:  Tin over brass;  Screws: Zinc-plated steel 

Breakdown Voltage

:  7500V

Agency Information

:  UL File E62622, CSA File 47235; IEC

Compliance; CE Certified

Dimensions - in

Poles

A

B

Poles

A

B

Poles

A

B

02

2.51

2.06

06

5.26

4.81

10

8.01

7.56

03

3.20

2.75

07

5.95

5.50

11

8.70

8.25

04

3.89

3.44

08

6.64

6.19

12

9.39

8.94

05

4.58

4.13

09

7.33

6.88

1” = 25.4mm.

0.15 dia.

(3.8)

0.687
(17.4)

0.22
(5.6)

A

B

0.625
(15.9)

1.12

(28.4)

0.687
(17.4)

0.562
(14.3)

1.81

(46.0)

0.76

(19.3)

0.46 (11.7)

1.34

(34.0)

0.22 dia. (5.6)

TB400 - in (mm)

TB400-05

Catalog Number Build-A-Code

Series

Poles

Screw Options

Marking

Custom Options

TB400

02

to 

12

Blank

= Steel philslot, zinc-plated

Not available

OJ14*

- Jumper over barrier

00

= Screws shipped bulk

B      

= Brass philslot, nickel-plated

ST    

= Stainless steel, philslot

*Contact factory for pole configuration.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Catalog Number Build-A-Code - KU Series

Series

Poles

Screw Options

Covers

Marking Strip

KU

= Standard block

02

to 

12

00

= Screws shipped bulk

WC

= Top cover &

MT

= Matte finish

KUX    

= Short block

W

= Brass washer head,

2 end plates

NU

= Numbered 1 to 12, horizontal

KURL  

= Standard w/removable link

nickel-plated

NUV

= Numbered 1 to 12, vertical

KUXRL

= Short block w/removable link

P

= Steel screw w/pressure plate

PT

= Marker strip for cover

zinc-plated

BP

= Brass philslot, nickel-plated

Catalog Number Build-A-Code - KU__SC Series

Series

Poles

Screw Options

Covers

Marking Strip

KUSC

=   Standard w/shorting strap

02 to 12

00

=  Screws shipped bulk

WC

= Top cover &

PT

= Marker strip for cover

& 4 shorting screws

W

=   Brass washer head,

2 end plates

KUXSC

= Short block w/shorting strap

nickel-plated

& 4 Shorting screws

P

=   Steel screw w/pressure plate

zinc-plated

BP

= Brass philslot, nickel-plated

Requires WC cover option

For more information, visit www.cooperbussmann.com/DatasheetsEle

375

Connector

s

Double Row Terminal Blocks

Series KU

Specifications
Ratings:

Volts: — 600V

Amps: — 60A*

Center Spacing

: 0.625˝ (15.88mm)

Number of Poles

:  2- to 12-poles**

Wire Range

:  #6-22 AWG Cu

Screw Size:

#10-32

Torque Rating:  

20 lb-in

Distance Between Barriers:

0.437 ˝ (11.09mm)

Mounting

:  Panel Mount

Material

:  Molded base:  Black, UL rated 94V1 Noryl

Terminal plating:  Nickel over brass

Operating Temperature

:  105°C max.

Agency Information

:  UL File E62622, CSA File 47235

* 60A rating achieved with #6 copper wire crimped to ring terminal.
** Only even number pole configurations (3-pole = exception).

Dimensions - in

KU

KUX Only

Poles

A

B

A

02

2.50

1.62

2.00

03

3.12

2.25

2.62

04

3.75

2.87

3.25

06

5.00

4.12

4.50

08

6.25

5.37

5.75

10

7.50

6.62

7.00

12

8.75

7.87

8.25

1” = 25.4mm.

MTMU##

NUM##

JU12

NUE

NUC##

Molded Marking Tape

Molded Marking

Jumper

End Piece for NUC

Cover

Matte Finish

Tape

12 Circuits

1.25

(31.8)

A

B

#10 screw

clearance

0.62

(15.9)

1.50

(38.1)

2.00

(50.8)

0.43

(11.1)

0.50

(12.7)

Series KU - in (mm)

Accessories***

***Accessories must be orderd seperately

.

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

376

Connectors

Power Feed Through Terminal Blocks

Series C7021

Specifications
Description:

Power

feed through terminal
block with two rows 

1

4

-20 studs capable of

accommodating the
industry standard 
two-hole compression
lugs on both studs in
parallel.

Ratings:

Volts: — 300V

Amps: — 115/175A* per pole

Center Spacing:

0.690" (17.5mm).

Wire Range:

AWG #3/0-8.

Poles:

1- to 6-poles.

Bolt Hole Spacing:

0.625" or 

5

8

” (15.88mm).

Stud:

Standard 

1

4

-20 stud (tin-plated brass) or optional M6

stud.

Mounting:

#6 thread cutting screws (not included) or 

optional mounting ears.

Torque Rating:

36 lb-in.

Operating Temperature:

130°C.

Agency Information:

UL/CSA; CE Certified.

*175 achieved using both studs in parallel, 115A using a single stud per line.

Typical Applications

• Applications requiring up to 175A utilizing a 2-hole 

compression lug on 

5

8

" centers

• Input/output block for telecommunications power panels
• Use to eliminate busbars

9.6

(0.38)

28.0

(1.10)

ø12.2 TYP

(0.48)

55.7

(2.19)

12.5

(0.49)

Ø 9.0 TYP

(0.35)

D

A

C

15.8

(0.62)

5.4

(0.21)

7.9

(0.31)

1/4-20 UNC-2A

Thread TYP

15.8

(0.62)

17.5 TYP

(0.69)

24.0

(0.94)

14.5 TYP

(0.57)

14.5 TYP

(0.57)

Blind Hole for #6
Thread Cutting
Screw

15.0 TYP
(0.59)

33.0

(1.30)

12.7

(0.50)

B

30.0

(1.18)

1.6

(R.06)

14.2

( ø.56)

E

A

Catalog Number Build-A-Code

Series

Poles

Mount Ends

Studs

Hardware

C7021  –                               

01 = 1-Pole (2 studs)

Blank = Mount ends

Blank = Standard

Blank = No hardware

02 = 2-Pole (4 studs)

N = No mount ends

M6 = M6 Studs

0 = Bulk pack, one set

03 = 3-Pole (6 studs)

1 = Bulk pack, two sets

04 = 4-Pole (8 studs)

2 = Assembled, bottom

05 = 5-Pole (10 studs)

3 = Assembled, top

06 = 6-Pole (12 studs)

4 = Assembled, both sets

Dimensions - mm (in)

Catalog
Numbers

A

B

C

D

E

C7021-01-X
C7021-02-X

17.5 (0.69)

-

54.4 (2.14)

67.3 (2.65)

31.8 (1.25)

C7021-03-X

34.9 (1.37)

-

70.9 (2.83)

84.8 (3.34)

49.2 (1.94)

C7021-04-X

52.3 (2.06)

-

89.3 (3.52)

102.2 (4.02)

66.7 (2.63)

C7021-05-X

69.8 (2.75)

-

106.8 (4.20)

119.7 (4.71)

84.2 (3.31)

C7021-06-X

87.2 (3.44)

-

124.2 (4.89)

134.1 (5.40)

101.7 (4.00)

C7021-01N-X
C7021-02N-X

17.5 (0.69)

36.1 (1.42)

-

-

31.8 (1.25)

C7021-03N-X

34.9 (0.69)

53.5 (2.11)

-

-

49.2 (1.94)

C7021-04N-X

52.3 (2.06)

71.0 (2.80)

-

-

66.7 (2.63)

C7021-05N-X

69.8 (2.75)

88.4 (3.48)

-

-

84.2 (3.31)

C7021-06N-X

87.2 (3.44)

105.9 (4.17)

-

-

101.7 (4.00)

Panel Cutouts

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For more information, visit www.cooperbussmann.com/DatasheetsEle

377

Connector

s

Power Feed Through Terminal Blocks

Series C7024

Specifications
Description:

A

power feed through
terminal block with
two rows of 

1

4

-28

studs capable of
accommodating the industry standard two-hole compression
lugs on 

3

4

" centers.

Ratings:

Volts: — 600V

Amps: — 115A per pole

Center Spacing:

0.75" (19.1mm).

Wire Range:

#2-8 AWG.

Poles:

1 to 12.

Bolt Hole Spacing:

0.75" (19.1mm).

Stud:

Standard 

1

4

-28 stud (tin-plated bronze).

Torque Rating:

36 lb-in.

Operating Temperature:

130°C.

Agency Information:

UL/C-UL, CSA; CE Certified.

Flammability Rating:

UL 94V0.

Catalog Numbers

Catalog

“A” Dimension- mm (in)

Number

Poles

±0.4 (±0.02)

“B” Dimension- mm (in)

C7024-01

01

21.6 (0.85)

-

C7024-02

02

40.6 (1.60)

19.05 ±0.08 (0.750 ±0.003)

C7024-03

03

59.7 (2.35)

38.10 (1.500)

C7024-04

04

78.7 (3.10)

57.15 ±0.26 (2.250 ±0.010)

C7024-05

05

97.8 (3.85)

76.2 (3.00)

C7024-06

06

116.8 (4.60)

95.25 ±0.26 (3.750 ±0.010)

C7024-07

07

135.9 (5.35)

114.30 ±0.38 (5.250 ±0/015)

C7024-08

08

154.9 (6.10)

133.35 ±0.38 (5.25 ±0.015)

C7024-09

09

174.0 (6.85)

152.40 ±0.38 (6.00 ±0.015)

C7024-10

10

193.0 (7.60)

171.45 ±0.38 (6.750 ±0.015)

C7024-11

11

212.1 (8.35)

190.50 ±0.38 (7.500 ±0.015)

C7024-12

12

231.1 (9.10)

209.55 ±0.38 (8.250 ±0.015)

]

[0.106

2.70TYP

]

[0.02

0.5 TYP

]

[0.52

13.2TYP

B

]

[

0.003

±

0.750

0.08

19.06

]

[0.70

17.8TYP

]

[0.124

3.16TYP

16.53TYP

[0.651]

A

]

[1.60

40.6

]

[1.10

28.0

]

[0.700

17.780

MIN. AT STUD PAD

TYP

Ø

Ø14.4

[0.57]

Typical Applications

• Applications requiring up to 115A utilizing a 2-hole 

compression lug on 

3

4

" centers

• Ideal as an input/output block for telecommunications power

panels

• Use to eliminate busbars

Dimensions - mm (in)

Catalog Number Build-A-Code

Series

Poles

C7024  –                               

01-12

Connectors

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

378

Full range of disconnect switches 
with versatile options and 
accessories that ship within 
24 hours

Open and enclosed 
disconnect switches

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

379

Disconnect

Switches

Compact Circuit Protector (CCP) disconnect switches

30A Class CC, Midget & 10x38 .............................380-381

30A 60A and 100A Class CF .................................382-383

CCPB - Compact Circuit Protector Base ..............384-385

UL 98 fused disconnect switches 30 to 800A

Introduction & Agency Information................................386

Product Line Summary..................................................387

30A Compact Class CC & Class J ........................388-389

30A Class J ............................................................390-391

60A Compact Class J ............................................392-393

60A Class J ............................................................394-395

100A Class J ..........................................................396-397

200A & 400A Class J .............................................398-400

600A Class J and 800A Class L ............................402-403

UL 98 non-fused disconnect switches 30 to 1200A

Introduction & Agency Information................................404

Product Line Summary..................................................405

30A, 60A and 100A Compact ................................406-407

100A, 200A and 400A Standard ............................408-409

600A, 800A, 1000A and 1200A Standard..............410-411

UL 508 non-fused disconnect switches 16 to 80A

Introduction and Agency Information............................412

Product Line Summary..................................................413

16A, 25A, 40A, 63A and 80A Standard .................414-416

Enclosed UL 98 & UL 508 disconnect switches

Introduction & Agency Information................................417

Fused UL 98

30A to 800A Enclosed Disconnects ......................418-419

Non-Fused UL 98

30 to 1200A Enclosed Disconnects.......................420-421

Non-Fused UL 508

16 to 80A Enclosed Disconnects...........................422-423

Fused, dead front disconnect switches .................424

Disconnect Switches

Section Contents

Page

Scan this tag to get the

latest product information for the

New Family of Disconnect Switches

and Accessories.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

Visit us on the web at 

www.cooperbussmann.com/Disconnects

380

Switch

Max Horsepower Rating

Amp

Fuse

Number

120

240

480

600

Wire

Part

Rating

Class

of Poles

Volts

SCCR

Vac

Vac

Vac

Vac

Wire Size

Type*

Number

30

CC

1

600Vac

200kA

0.5

75°C Cu CCP-1-30CC

30

CC

2

600Vac

200kA

2

Single/Dual

75°C Cu CCP-2-30CC

#18-6 Sol/Str

30

CC

3

600Vac

200kA

3

4

7.5

75°C Cu CCP-3-30CC

30

UL Midget

1

240Vac

10kA

Single

75°C Cu CCP-1-30M

32**

10x38 IEC

400Vac

120kA

#4 Sol/Str

30

UL Midget

2

240Vac

10kA

75°C Cu CCP-2-30M

32**

10x38 IEC

400Vac

120kA

30

UL Midget

3

240Vac

10kA

75°C Cu CCP-3-30M

32**

10x38 IEC

400Vac

120kA

Spade

30

CC

1

80Vdc

20kA

Terminal

††

75°C Cu CCP-1-30DCC

30

CC

1

80Vdc†

10kA†

75°C Cu CCP-1-30DCM

32**

10x38 IEC

* 75°C or higher.

** 32A Class aM, 25A Class gG.

† SCCR May be lower, refer to installed fuse data sheets.

†† Spade terminal, 30A max, insulated flange, wire size #12-10 for #8 stud.

Specifications

Agency Information

• CE Compliant

• RoHS Compliant

• For 

Class CC

fuse version

- UL 98 Listed, File E302370, Guide WHTY

- cULus to CSA Standard 22.2 No. 4-04, File 302370,

Guide WHTY7

• For 

UL Midget and 10X38 IEC

fuse version

- UL 508 Listed, File E161278, Guide 8R29

- cULus Certified 22.2 No. 14-05

- IEC 60947-3 AC23A

- IEC 60947-3 DC23A

Terminals

• Single/dual conductor box lug or spade terminal suitable

for line, load or accessory connection

• Torque: - #18-10 20Lb-In

- #8-4 35Lb-In

Storage and Operating Temperature

• -20ºC to 75ºC*

* For fuse performance under or above 25ºC, consult fuse performance derating charts

in the Bussmann publication titled 

Selecting Protective Devices

(SPD), reorder #3002.

Flammability Rating UL 94V0

Lockout/Tagout Provisions

• 4mm shank lock or standard pin-out devices

Mounting

• 35mm DIN-Rail

Local Open Fuse Indication Minimum Voltage**

• 90Vac for AC versions

• 12Vdc for DC versions

** Circuit must be closed for indication light to illuminate.

Features

• IP20 Finger-safe construction with #10 or larger wire

• Switch interlock prohibits removing the fuse under load

Accessories

• Auxiliary contacts

• PLC Wired remote fuse indication

Switch Handle

Padlock Provision

Open Fuse 

Indication Light

Fuse Holder

Knob

Spade Terminal

Circuit Marking

Area

Box Lug

Terminal

Compact Circuit Protector (CCP) Disconnect Switch—30A

1-, 2- & 3-Pole, Class CC, UL Midget & 10x38mm IEC

Available Bussmann Fuses

Class Type

Data Sheet #

CC

LP-CC Time-Delay, Current Limiting

1023

CC

FNQ-R Time-Delay

1014

CC

KTK-R Fast-Acting

1015

M

FNM Time-Delay

2028

M

FNQ Time-Delay

1012

M

KTK Fast-Acting

1011

M

BAF Fast-Acting

2011

M

KLM Fast-Acting 600Vac/dc

2020

Data Sheet: 1157

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

Compact Circuit Protector (CCP) Disconnect Switch—30A

1-, 2- & 3-Pole, Class CC, UL Midget & 10x38mm IEC

Visit us on the web at 

www.cooperbussmann.com/Disconnects

381

Disconnect

Switches

CCP-_-30_ Accessories

Minimum

Signal

Circuit

Agency

Part

Description

Configuration

Output

Voltage

Information

Number

Auxiliary Contacts NO+NC

UL 98 Recognized,

for Switch Status

1 per CCP

5A/240Vac

cURus 22.2 No. 4-04,

CCP-AUX*

IEC 60947-5-1 AC15

Wired Remote Fuse Indication

1 per CCP

24Vdc

100Vac

UL 98 Recognized,

CCP-PLC-IND*

for PLC Applications

cURus 22.2 No. 4-04

* Refer to Data Sheet # 1157 for details.

Dimensions – mm (in)

Class CC, UL Midget & I0x38 IEC

92.7

(3.7)

17.5

(0.7)

45

(1.8)

35

(1.4)

79.8

(3.1)

52.5

(2.1)

49.2

(1.9)

Auxiliary Contacts

PLC Indicator

(Includes leads with spade terminals)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

Visit us on the web at 

www.cooperbussmann.com/Disconnects

382

Compact Circuit Protector (CCP) Disconnect Switch—30, 60 & 100A

1-, 2- & 3-Pole, Class CF CUBEFuse™

Switch

Max Horsepower Rating

Amp

Fuse

Number

120

240

480

600

Wire

Part

Rating

Class

of Poles

Volts

SCCR

Vac

Vac

Vac

Vac

Wire Size

Type*

Number

30

CF

1

600Vac

200kA

1.5

75°C Cu CCP-1-30CF

125Vdc

30

CF

2

600Vac

200kA

3

Single/Dual

75°C Cu CCP-2-30CF

125Vdc

#18-6 Sol/Str

30

CF

3

600Vac

200kA

5

15

10

75°C Cu CCP-3-30CF

125Vdc

Single

60

CF

1

600Vac

200kA

3

#4 Sol/Str

75°C Cu CCP-1-60CF

125Vdc

60

CF

2

600Vac

200kA

7.5

Spade

75°C Cu CCP-2-60CF

125Vdc

Terminal**

60

CF

3

600Vac

200kA

7.5

20

10

75°C Cu CCP-3-60CF

125Vdc

100

CF

1

600Vac 200kA

5

Single

75°C Cu CCP-1-100CF

#8-10 Sol/Str

100

CF

2

600Vac 200kA

10

#8-1 Str

75°C Cu CCP-2-100CF

Dual #6 Str

100

CF

3

600Vac 200kA

20

50

50

Spade

75°C Cu CCP-3-100CF

Terminal**

* 75°C or higher.

** Spade terminal, 30A max, insulated flange, wire size #12-10 for #8 stud.

Specifications

Agency Information

• CE Compliant

• RoHS Compliant

• UL 98 Listed, File E302370, Guide WHTY

• cULus to CSA Standard 22.2 No. 4-04, File 302370,

Guide WHTY7

Terminals

• Single/dual conductor box lug or spade terminal suitable

for line, load or accessory connection

• Torque: 0-60A: - #18-10 20Lb-In

- #8-4 35Lb-In

70-100A: - #18-10 Single 25Lb-In

- #8-2 Single 35Lb-In

- #1 Single 40Lb-In

- #6 Dual 45Lb-In

Fuses

• Uses finger-safe Class CF CUBEFuse™ with 

Class J performance

- Low-Peak™ dual-element, time-delay*

- Non-indicating 1-100A

- Indicating 6-100A

- Fast-Acting** 1-100A

* See Data Sheet # 9000

** See Data sheet # 2147

Storage and Operating Temperature

• -20ºC to 75ºC***

*** For fuse performance under or above 25ºC, consult fuse performance derating charts

in the Bussmann publication titled 

Selecting Protective Devices

(SPD) reorder #3002.

Flammability Rating UL 94V0

Lockout/Tagout Provisions

• 4mm shank lock or standard pin-out devices

Mounting

• 35mm DIN-Rail

Local Open Fuse Indication Minimum Voltage

• 90Vac/115Vdc

† Circuit must be closed for indication light to illuminate.

Features

• Ampacity rejecting disconnects will not accept

CUBEFuse amp ratings greater than switch rating

• IP20 Finger-safe construction with #10 or larger wire

• Switch interlock prohibits removing the fuse under load

Accessories

• Auxiliary contacts

• PLC Wired remote fuse indication (up to 60A)

Circuit

Marking Area

Lockout Provision

Switch Handle

Spade Terminal

Box Lug

Terminal

Open Fuse 

Indication Light

Fuse Holder

Data Sheet: 1157

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

Compact Circuit Protector (CCP) Disconnect Switch—30, 60 & 100A

1-, 2- & 3-Pole, Class CF CUBEFuse™

Visit us on the web at 

www.cooperbussmann.com/Disconnects

383

Disconnect

Switches

CCP-_-_CF Accessories

Minimum

Signal

Circuit

Agency

Part

Description

Configuration

Output

Voltage

Information

Number

Auxiliary Contacts NO+NC

UL 98 Recognized,

for Switch Status up to 60A

1 per CCP

5A/240Vac

cURus 22.2 No. 4-04,

CCP-AUX*

IEC 60947-5-1 AC15

Auxiliary Contacts NO+NC

1 per CCP

5A/240Vac

UL 98 Recognized,

CCP-AUX-100*

for Switch Status 70 to 100A

CSA C22.2 No. 4

Wired Remote Fuse Indication

1 per CCP

24Vdc

100Vac

UL 98 Recognized,

CCP-PLC-IND*

for PLC Applications

cURus 22.2 No. 4-04

Wired Remote Fuse Indication

1 per CCP

8A/24Vdc

100Vac

UL 98 Recognized,

CCP-PLC-100*

for PLC Applications up to 60A

CSA C22.2 No. 4

* Refer to Data Sheet # 1157 for details.

Auxiliary Contacts

PLC Indicator

(Includes leads with spade terminals)

Dimensions – mm (in)

30 and 60 Amp

100 Amp

50.4
(2.0)

25.1
(1.0)

75.7
(3.0)

9.1

(0.4)

7.6

(0.3)

60.3 (2.4)

113.9

(4.5)

49.2

(1.9)

75.1

(3.0)

30A

 CUBEFuse

83.3 (3.3)

60A

 CUBEFuse

89.1 (3.5)

79.5
(3.0)

147.1

(5 8)

50.5
(2.0)

25.15

(1.0)

91.2

(3.6)

56.6

(2.2)

100.0

(3.9)

67.7

(2.7)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

Visit us on the web at 

www.cooperbussmann.com/Disconnects

384

Specifications:

• CCPB Ampacity rejection breaks: 15A, 20A, 30A, 40A,

50A, 60A, 70A, 90A and 100A.

• 1-, 2- and 3-Pole versions

• For systems 600Vac (or less)

• Box lug loadside terminal:

   • 18-6AWG single & dual rated, solid or stranded – 

75°C, Cu only

   • 4AWG single – 75°C, Cu only

The revolutionary Bussmann CCPB with CUBEFuse

is

designed as a fused branch circuit disconnect with fuse
holder for the Bussmann Quik-Spec™ Coordination
Panelboard. The CCPB with CUBEFuse simplifies selective
coordination and allows for isolation of individual branch
circuit loads for safe work practices.

Agency Information:

UL 98 Listed, File E302370, Guide WHTY

cULus to CSA Standard 22.2 No. 4, File E302370, 
Guide WHTY7

CE Compliant

Shipping Weight:

2.03 lbs per carton

Carton quantity:

6 poles

Environmental Data

Storage and operating temperature: -20ºC to 75ºC**

Product Features and Benefits

•  Uses finger-safe Class CF Low-Peak

CUBEFuse with

current-limiting, time-delay Class J performance*

•  High Short-Circuit Current Ratings at 200kA

•  Disconnect rated to provide means for load isolation

•  Full voltage rated at 600Vac

•  UL 98 Listed and suitable for branch circuit disconnect

and branch circuit protection

•  1-, 2- and 3-pole versions are horsepower rated

•  Patented rejection feature helps prevent overfusing

•  Complies with UL and cULus

•  Open fuse indication light per pole

•  Additional open fuse indication can be provided by using

the indicating CUBEFuse version

•  Built-in switch/fuse interlock prohibits removing the fuse

while energized

•  Permanent lockout/tagout provisions

•  Lock-ON provision

*See data sheet 9000 for CUBEFuse specifications.

**For fuse performance under or above 25ºC, consult fuse performance 

derating charts.

• Box lug loadside terminal torque: 18-10AWG 20 Lb-In
  (2.2 N•m), 8-4AWG 35 Lb-In (3.9 N•m)

• Spade terminal load connection:
  Max. 30A suitable for use with #8-32UNC screw

• Bolt-on style bus connector, #10-32-UNC Hex flange
  Phillips screw, torque to 25 Lb-In (2.8N•m)

• Lockout/tagout: 4mm shank lock

• Bolt-mounted design into Quik-Spec Coordination
  Panelboard bus

• Local indication: illumination requires closed circuit and
  minimum 90Vac operating voltage

• RoHS compliant

Compact Circuit Protector Base (CCPB)
CUBEFuse

                                                                                                          

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Visit us on the web at 

www.cooperbussmann.com/Disconnects

385

Compact Circuit Protector Base (CCPB)
CUBEFuse

                                                                                                          

   

CCPB Part          

Poles

     Voltage          Time-Delay           Time-Delay           Fast-Acting         Max. Fuse**     

SCCR

      

Hp Ratings***

     Numbers                           Rating        Non-Indicating         Indicating*         Non-Indicating         Ampacity                                    

  CCPB-1-15CF           1                                                                                                                                                                  0.5Hp@120V
  CCPB-2-15CF           2                          TCF1RN, TCF3RN, 

   TCF6, TCF10,     

FCF1RN, FCF3RN,                                               1.5Hp@240V

                                              600Vac    TCF6RN, TCF10RN,

         TCF15         

FCF6RN, FCF10RN,          15A            200kA          3Hp@240V

  CCPB-3-15CF           3                                  TCF15RN                                            FCF15RN                                                        5Hp@480V

                                                                                                                                                                                                      7.5Hp@600V

  CCPB-1-20CF           1                                                                                                                                                                 0.75Hp@120V
  CCPB-2-20CF           2                                                                                                                                                                   2Hp@240V
                                              600Vac         

TCF17-1/2RN,

         TCF17-1/2,              FCF20RN                  20A            200kA          3Hp@240V

  CCPB-3-20CF           3                                  

TCF20RN

                 TCF20                                                                                      7.5Hp@480V

                                                                                                                                                                                                      10Hp@600V

  CCPB-1-30CF           1                                                                                                                                                                  1.5Hp@120V
  CCPB-2-30CF           2                                                                                                                                                                   3Hp@240V
                                              600Vac            

TCF25RN,

          TCF25, TCF30           FCF25RN,                  30A            200kA          5Hp@240V

  CCPB-3-30CF           3                                  

TCF30RN

                                            FCF30RN                                                       15Hp@480V

                                                                                                                                                                                                      10Hp@600V

  CCPB-1-40CF           1                                                                                                                                                                  2.0Hp@120V
  CCPB-2-40CF           2                                                                                                                                                                   3Hp@240V
                                              600Vac            

TCF35RN,

          TCF35, TCF40           FCF35RN,                  40A            200kA        7.5Hp@240V

  CCPB-3-40CF           3                                  

TCF40RN

                                            FCF40RN                                                       20Hp@480V

                                                                                                                                                                                                      10Hp@600V

  CCPB-1-50CF           1                                                                                                                                                                  3.0Hp@120V
  CCPB-2-50CF           2                                                                                                                                                                   5Hp@240V
                                              600Vac            

TCF45RN,

          TCF45, TCF50           FCF45RN,                  50A            200kA        7.5Hp@240V

  CCPB-3-50CF           3                                  

TCF50RN

                                            FCF50RN                                                       20Hp@480V

                                                                                                                                                                                                      10Hp@600V

  CCPB-1-60CF           1                                                                                                                                                                  3.0Hp@120V
  CCPB-2-60CF           2                                                                                                                                                                  7.5Hp@240V
                                              600Vac            TCF60RN                 TCF60                 FCF60RN                  60A            200kA        7.5Hp@240V
  CCPB-3-60CF           3                                                                                                                                                                  20Hp@480V

                                                                                                                                                                                                      10Hp@600V

CCPB-1-70CF              1                                                                                                                                                                  3.0Hp@120V
CCPB-2-70CF              2                                                                                                                                                                  7.5Hp@240V

                                              600Vac            TCF70RN                 TCF70                 FCF70RN                  70A            200kA         15Hp@240V

CCPB-3-70CF              3                                                                                                                                                                  30Hp@480V
CCPB-1-90CF              1                                                                                                                                                                  5.0Hp@120V
CCPB-2-90CF              2                                                                                            FCF80RN,                                                      10Hp@240V

                                              600Vac            TCF90RN                 TCF90                 FCF90RN                  90A            200kA         20Hp@240V

CCPB-3-90CF              3                                                                                                                                                                  40Hp@480V
CCPB-1-100CF            1                                                                                                                                                                  5.0Hp@120V
CCPB-2-100CF            2                                                                                                                                                                  10Hp@240V

                                              600Vac           TCF100RN               TCF100               FCF100RN                100A           200kA         20Hp@240V

CCPB-3-100CF            3                                                                                                                                                                  50Hp@480V

CUBEFuse™

(Class J performance)

Technical Ratings

*1A and 3A indicating CUBEFuse not available. Correct fit with CCPB disconnect requires indicating CUBEFuse with date code R38 or later.
**Any fuse with an amp rating less than or equal to the max fuse rating may be used.Example: TCF15 may be used with CCPB-1-20CF.
***Do not use UPS/Critical Application fast-acting CF with motors.

Disconnect Switches

Disconnect

Switches

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—30 to 800A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

386

Description

Bussmann UL 98 and UL 489 fused disconnect switches

“break” and “make” power circuits ON and OFF load.

The switches employ double break contacts per pole that

help ensure complete isolation of the fuse when the switch is

in the "OFF" position.

Features

• Make and break power under load

• Double break by pole

• DIN-Rail or panel mount (30-100A)

• Up to 200kA Short-Circuit Current Rating

• Finger-safe covers

• Compact footprints available

• Defeatable handles automatically re-latch when the panel

door is closed

• Most disconnect switches are front, right side, flange or 

direct handle operable

• NFPA 79 Compliant handle kits

Agency Information

• UL 98, Guide WHTY, File E155130

• UL 489, Guide WJAZ, File E359801

• CSA 22.2 No. 4, File 257020

• Conforms with IEC 60947-3

• NFPA 79 (2002 Edition)

Online Resources

Visit 

www.cooperbussmann.com/Disconnects

for:

• CAD Drawings

• Instruction Sheets

• UL Information

Available Bussmann Fuses

Class Type

Data Sheet #

CC

LP-CC Time-Delay, Current Limiting

1023

CC

FNQ-R Time-Delay

1014

CC

KTK-R Fast-Acting

1015

J

LPJ Time-Delay, Current Limiting

1006 (0-60A)

J

1007 (70-600A)

J

With 

easy

ID™ open fuse indication

1062 (6-60A)

J

1063 (70-600A)

J

JKS Fast-Acting Fuses

1026 (0-60A)

J

1027 (70-600A)

J

DFJ High Speed Drive Fuse

1048 (0-600A)

L

KRP-C Time-Delay, Current Limiting

1008

L

KTU Fast-Acting 

1010

L

KLU Time-Delay 

1013

QuikShip Everyday Service ships the most common part 

numbers within 24 hours. Contact your Bussmann 

representative for details. 

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—30 to 800A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

387

Disconnect

Switches

Part Number

2-Pole

RDF30J-2

RDF60J-2-COMP

RDF60J-2

RDF100J-2

RDF200J-2

RDF400J-2

RDF600J-2

RDF800L-2

3-Pole

RDF30CC-3

RDF30J-3-COMP

RDF30J-3

RDF60J-3-COMP

RDF60J-3

RDF100J-3

RDF200J-3

RDF400J-3

RDF600J-3

RDF800L-3

3-Pole + Neutral

RDF30CC-3N

RDF30J-3N-COMP

4-Pole

RDF30J-4

RDF60J-4-COMP

RDF60J-4

RDF100J-4

RDF200J-4

RDF400J-4

RDF600J-4

RDF800L-4

UL Standard

UL 489

UL 489

UL 98

UL 98

UL 98

UL 98

UL 98

UL 98

UL 98

UL 98

Fuse Class

CC

J

J

J

J

J

J

J

J

L

Max Fuse/Ampacity

30

30

30

60

60

100

200

400

600

800

Switch Type

Compact

Compact

Standard

Compact

Standard

Standard

Standard

Standard

Standard

Standard

Handle Operation

Front

Front

Front/Side

Front/Side

Front/Side

Front/Side

Front/Side

Front/Side

Front

Front

Flange

Flange

Flange

Flange

Flange

UL Electrical Ratings

Max AC Volts

600Vac

600Vac

600Vac

600Vac

600Vac

600Vac

600Vac

600Vac

600Vac

600Vac

Max DC Volts*

250Vdc

250Vdc

250Vdc

250Vdc

250Vdc

600Vdc

600Vdc

Std AC Horsepower Ratings

1-Phase, 240Vac

3

10

10

10

10

10

3-Phase, 240Vac

3

3

3

7.5

7.5

15

25

50

75

75

3-Phase, 480Vac

5.0

5.0

5.0

15

15

25

50

100

150

200

3-Phase, 600Vac

7.5

7.5

7.5

15

15

30

60

125

200

250

Max AC Horsepower Ratings

3-Phase, 240Vac

7.5

7.5

7.5

15

15

30

60

125

200

200

3-Phase, 480Vac

15

15

15

30

30

60

125

250

400

500

3-Phase, 600Vac

20

20

20

50

50

75

150

350

500

500

DC Horsepower Ratings

125Vdc

3

5

5

7.5

20

250Vdc

5

10

10

20

50

Electrical Characteristics

SCCR

100kA

100kA

200kA

100kA

200kA

200kA

200kA

200kA

200kA

200kA

Terminal Lugs/Kits

Integral

Integral

Integral

Integral

Integral

Integral

Mounting Torque - Lb-In (N•m)

160 (18)

310 (35)

310 (35)

310 (35)

Wire Type

75°C Cu

75°C Cu

75°C Cu

75°C Cu

75°C Cu

75°C Cu

75°C Cu/Al

75°C Cu/Al

75°C Cu/Al

75°C Cu/Al

Wire Range & 
Torque - Lb-In (N•m)

Solid

#14-10

#14-10

#14-10

#14-10

#12-10

#12-10

27 (3.1)

27 (3.1)

31 (3.5)

31 (3.5)

35.4 (4)

35.4 (4)

Stranded

#14-10

#14-10

#14-6 

#14-6

#12-1

#12-1

#6-300MCM

#4-600MCM

(2) #2-600MCM

(2) #2-600MCM

27 (3.1)

27 (3.1)

31 (3.5)

31 (3.5)

35.4 (4)

35.4 (4)

275 (31)

550 (62)

375 (42.4)

375 (42.4)

Dual 1/0-250MCM 

550 (62)

Mechanical Characteristics

Endurances/Cycles

10,000

10,000

10,000

10,000

10,000

10,000

8000

6000

5000

5000

Physical Characteristics

Dimensions 

See drawings on
product pages

Weight - Lbs (KG)

2-Pole

3.0 (1.3)

3.1 (1.4)

4.0 (1.8)

4.07 (1.8)

5.7 (2.6)

11.4 (5.2)

31.7 (14.4)

31.7 (14.4)

3-Pole

1.3 (0.6)

1.4 (0.6)

3.8 (1.7)

4.1 (1.8)

5.3 (2.4)

5.3 (2.4)

7.8 (3.5)

16.6 (7.6)

44.2 (20.1)

44.2 (20.1)

3-Pole + Neutral

1.4 (0.6)

1.5 (0.7)

4-Pole

4.7 (2.1)

4.8 (2.2)

X.X (2.9)

6.49 (2.9)

10.8 (4.9)

21.8 (9.9)

56.8 (25.8)

56.8 (25.8)

Environmental

Operating Temp. Range

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

Flammability Rating

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

Accessories

Lug Kit

Integral

Integral

Integral

Integral

Integral

Integral

Handles

Direct

Front Selector

Front Pistol

Side  Pistol

Flange

Cable

Shaft

NFPA Through Door Handle

Shafts c/s - mm

5x5

5x5

10x10

10x10

10x10

10x10

10x10

10x10

12X12

12X12

Terminal Shrouds

Not Required

Not Required

Not Required

Not Required

Not Required

Not Required

Auxiliary Contacts

(1)  NO

(1)  NC

AC Ratings

Volts

600

600

600

600

600

600

600

600

600

600

Amps

10

10

10

10

10

10

10

10

10

10

• Available, see product page for details and part numbers.

— Not available.

* General purpose only, not photovoltaic rated.

Specifications

RDF30CC-3

RDF60J-3

RDF200J-3

RDF600J-3

RDF30J-3 / RDF60J-3-COMP

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 12

Black

N

Y

Y

H12-05B

1, 3R, 12

Red/Yellow

N

Y

Y

H12-05R

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-05B

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-05R

1, 3R, 4, 4X, 12

Black

Y

Y

Y

H4X-05TB

1, 3R, 4, 4X, 12

Red/Yellow

Y

Y

Y

H4X-05TR

Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles

- shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-05BHD

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-05RHD

Shafts for Pistol Handles

Length

Mounting Depth

Part

in (mm)

(X) in (mm)

Number

7.9 (200)

4.02~9.65 (102~245)

SH2-200

12.6 (320)

4.02~14.37 (102~365)

SH2-320

15.7 (400)

4.02~17.52 (102~445)

SH2-400

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—30A

Compact Class CC & Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

388

(1)

(2)

For a Complete Assembly, Please Select:

Select for Standard 

Applications

Accessories

Switch

Max Horsepower Rating, 3-Ph

Amp

Fuse

Number

220/

440/

600

Wire

Wire

Part

Rating

Class

of Poles

SCCR

240Vac

480Vac

Vac

Size

Type

Number

30

CC

3

100kA

7.5

15

20

#14-10 Sol/Str

75°C Cu

RDF30CC-3

30

CC

3 + Ntrl*

100kA

7.5

15

20

#14-10 Sol/Str

75°C Cu

RDF30CC-3N

30

J

3

100kA

7.5

15

20

#14-10 Sol/Str

75°C Cu

RDF30J-3-COMP

30

J

3 + Ntrl*

100kA

7.5

15

20

#14-10 Sol/Str

75°C Cu

RDF30J-3N-COMP

*

Neutral is switched.

Direct Mount Handle - 

mounts directly to switch, no shaft required

For Switch

Test

Part

Part Number

Color

Function

Padlockable

Number

RDF30CC-_

Black

Y

Y

DIR-05

RDF30J-_-COMP

Black

Y

Y

DIR-06

External Front Operated Selector Handle - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-04B

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-04R

Shafts for Selector Handles

Length

Mounting Depth

Part

in (mm)

(X) in (mm)

Number

7.9 (200)

4.02~9.65 (102~245)

SH1-200

12.6 (320)

4.02~14.37 (102~365)

SH1-320

15.7 (400)

4.02~17.52 (102~445)

SH1-400

NFPA Through the Door Handle Kit

- to be used with selector handle or front pistol handle

Test

Part

Color

Function

Padlockable

Defeatable

Number

Red

N

Y

N

H79-1

Auxillary Contacts

Contact

Number of  Continuous

Voltage

Maximum Number of Auxiliary Contacts

Part

Type

Contacts

Amp Rating

Rating

per Disconnect Switch Part Number

Number

NO

1

10A

600Vac

RDF30CC-_: 4 / 8 with BAC-HOLDER2

BAC05

(1)

NC

1

10A

600Vac

RDF30J-_-COMP: 2 /6 with BAC-HOLDER2

BAC06

(1)

Auxillary

Accepts 4 Auxillary Contacts:

Contact

BAC05 or BAC06

BAC-HOLDER2

(2)

Holder

or

or

or

or

S

WITCH

A

UXILIAR

Y

C

ONT

ACTS

H

ANDLE

X

X

+

+

and…

+

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—30A

Compact Class CC & Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

389

Disconnect

Switches

3.28
83.3

1.12
28.5

5.19 (131.8)

4.56

11

6

3.3

84

1

25.5

3.78

96 1.47

37.5

0.59

15

Fuse Cover Fully Open

3.89

99

1.12
28.5

4.13

105

1.47
37.5

0.59

15

4.56

11

6

3.3

84

1

25.5

Dimensions – in (mm)

• RDF30CC-_

•RDF30J-_-COMP

External Front Pistol Handles

External Front Selector Handle

Door Drilling Layout

0.78

4 Ø 0.27

0.55

Ø 1.46

4 Ø 7

Ø 37

20

20

14

0.55
14

0.78

H4X-05__
H12-05__

Ø3.07

1.73

2.75

65°

TEST

90

°

0

Direction of Front Operation

Pistol Handle Type

Ø78

70

44

I

Ø78 

37

88

13.5

Ø 22.5

3

40

4 Ø 7

Ø 31

28

With Mounting Nut

With 4 Mounting Screws

Door Drilling Layout

Selector Handle Type

0

I

90

°

Direction of Front Operation

Ø3.07 

1.45

3.46

1.57

4 Ø 0.27

1.10

Ø 1.22

0.11

0.53

Ø 0.88

H4X-04_

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—30A

Standard Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

390

NFPA Through the Door Handle Kit

- to be used with selector handle or front pistol handle

Test

Part

Color

Function

Padlockable

Defeatable

Number

Red

N

Y

N

H79-2

For a Complete Assembly, Please Select:

Select for Standard 

Applications

Switch

Max Horsepower Rating

1-Phase

3-Phase

DC*

Amp

Fuse No. of

220/

220/

440/

600

125

250

Wire

Wire

Part

Rating Class Poles

SCCR 240Vac

240Vac 480Vac Vac

Vdc

Vdc

Size

Type

Number

30

J

2

200kA

3

-

-

-

3

5

#14-10 Sol

75°C Cu

RDF30J-2

#14-6 Str

30

J

3

200kA

-

7.5

15

20

3

5

#14-10 Sol

75°C Cu

RDF30J-3

#14-6 Str

30

J

4

200kA

-

7.5

15

20

3

5

#14-10 Sol

75°C Cu

RDF30J-4

#14-6 Str

* DC Ratings use two poles in series.

Direct Mount Handle - 

mounts directly to switch, no shaft required

For Switch

Test

Part

Part Number

Color

Function

Padlockable

Number

All Switches

Black

Y

Y - On Switch

DIR-07

+

(1)

(2)

(3)

(4)

or

or

or

S

WITCH

H

ANDLE

X

or

External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 12

Black

N

Y

Y

H12-05B

1, 3R, 12

Red/Yellow

N

Y

Y

H12-05R

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-05B

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-05R

1, 3R, 4, 4X, 12

Black

Y

Y

Y

H4X-05TB

1, 3R, 4, 4X, 12

Red/Yellow

Y

Y

Y

H4X-05TR

Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-05BHD

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-05RHD

External Right Side Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

N/A

H4X-05SB

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

N/A

H4X-05SR

Shafts for Pistol Handles

Length

Mounting Depth

Part

in (mm)

(X) in (mm)

Number

7.9 (200)

5.30~9.06 (135~230)

SH5-200

12.6 (320)

5.30~13.78 (135~350)

SH5-320

15.7 (400)

5.30~16.93 (135~430)

SH5-400

Flange Handle

(1) 

- requires shaft operated mechanism or cable operated mechanism + cable

NEMA

Flange

Test

Part 

Type

Style

Function

Padlockable

Defeatable

Number

1, 3R, 4, 12

Standard

N

Y

Y

FLH1

1, 3R, 4, 4X, 12

Chrome Plated

N

Y

Y

FLH2

Shaft Operated Flange Mechanism

(2)

- includes shaft

For  Enclosure 

Part

Depth - in (mm)

Number

6~24 (152~613)

FLRM

Cable Operated Flange Mechanism and Cable

- must select Mechanism

(3)

and

Cable

(4)

Part

Item / Length

Number

Cable Mechanism

FLCM

36” (900mm) Cable

FLC36

60” (1500mm) Cable

FLC60

120” (3000mm) Cable

FLC120

 +

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—30A

Standard Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

391

Disconnect

Switches

Acc.

Auxillary Contacts

Contact

Number of

Continuous

Voltage

Max Number of Aux

Part

Type

Contacts

Amp Rating

Rating

Contacts per Switch

Number

NO

1

10A

600Vac

4

BAC05

NC

1

10A

600Vac

4

BAC06

Dimensions – in (mm)

5.35

136

5.87

149.3

1.41

36

1.46
37.2

4.84

123

1.41

36

4.02

102.1

2.68

68.07

1.57

40

5.31

135

1.79
45.5

Direct Mount Handle

DIR-07

3.50

(88.9)

2.16

(54.9)

0.86

(21.8)

1.06

(26.9)

4.68

(118.9)

1.55 

(39.4)

0.88

(22.3)

1.00

(25.4)

1.00

(25.4)

6.22

(158.0)

2.32

(58.9)

7.10

(180.3)

Ø0.50

(Ø12.7)

Ø0.28

(Ø7.1)

2.70

(68.6)

5.66

(143.8)

Flange Handle

FLH_

External Front & Right Side Pistol Handle

H4X-05__
H12-05__

0

I

90

°

Ø3.07

1.73

2.75

65

°

TEST

90

°

0

Direction of Front Operation

Handle Type

Direction of Right Side Operation

Door Drilling Layout

Ø78

70

44

0.78

4 Ø 0.27

0.55

Ø 1.46

4 Ø 7

Ø 37

20

20

14

0.55
14

0.78

I

and …

A

UX

C

ONT

ACTS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—60A

Compact Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

392

NFPA Through the Door Handle Kit

- to be used with selector handle or front pistol handle

Test

Part

Color

Function

Padlockable

Defeatable

Number

Red

N

Y

N

H79-2

For a Complete Assembly, Please Select:

Select for Standard 

Applications

Switch

Max Horsepower Rating

1-Phase

3-Phase

DC*

Amp

Fuse

Number

220/

220/

440/

600

125

250

Wire

Wire

Part

Rating

Class of Poles SCCR

240Vac

240Vac 480Vac Vac Vdc Vdc

Size

Type

Number

60

J

2

100kA

10

-

-

-

5

10

#14-10 Sol

75°C Cu

RDF60J-2-COMP

#14-6 Str

60

J

3

100kA

-

15

30

50

5

10

#14-10 Sol

75°C Cu

RDF60J-3-COMP

#14-6 Str

60

J

4

100kA

-

15

30

50

5

10

#14-10 Sol

75°C Cu

RDF60J-4-COMP

#14-6 Str

* DC Ratings use two poles in series.

Direct Mount Handle - 

mounts directly to switch, no shaft required

For Switch

Test

Part

Part Number

Color

Function

Padlockable

Number

All Switches

Black

Y

Y - On Switch

DIR-07

External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 12

Black

N

Y

Y

H12-05B

1, 3R, 12

Red/Yellow

N

Y

Y

H12-05R

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-05B

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-05R

1, 3R, 4, 4X, 12

Black

Y

Y

Y

H4X-05TB

1, 3R, 4, 4X, 12

Red/Yellow

Y

Y

Y

H4X-05TR

Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-05BHD

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-05RHD

External Right Side Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

N/A

H4X-05SB

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

N/A

H4X-05SR

Shafts for Pistol Handles

Length

Mounting Depth

Part

in (mm)

(X) in (mm)

Number

7.9 (200)

5.30~9.06 (135~230)

SH5-200

12.6 (320)

5.30~13.78 (135~350)

SH5-320

15.7 (400)

5.30~16.93 (135~430)

SH5-400

Flange Handle

(1) 

- requires shaft operated mechanism or cable operated mechanism + cable

NEMA

Flange

Test

Part

Type

Style

Function

Padlockable

Defeatable

Number

1, 3R, 4, 12

Standard

N

Y

Y

FLH1

1, 3R, 4, 4X, 12

Chrome Plated

N

Y

Y

FLH2

Shaft Operated Flange Mechanism

(2)

- includes shaft

For Enclosure

Part

Depth - in (mm)

Number

6~24 (152~613)

FLRM

Cable Operated Flange Mechanism and Cable

- must select Mechanism

(3)

and

Cable

(4)

Part

Item / Length

Number

Cable Mechanism

FLCM

36” (900mm) Cable

FLC36

60” (1500mm) Cable

FLC60

120” (3000mm) Cable

FLC120

+

(1)

(2)

(3)

(4)

S

WITCH

H

ANDLE

X

or

or

or

or

+

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—60A

Compact Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

393

Disconnect

Switches

Dimensions – in (mm)

5.35

136

5.87

149.3

1.41

36

1.46
37.2

4.84

123

1.41

36

4.02

102.1

2.68

68.07

1.57

40

5.31

135

1.79
45.5

Direct Mount Handle

DIR-07

External Front & Right Side Pistol Handle

H4X-05__
H12-05__

0

I

90

°

Ø3.07

1.73

2.75

65

°

TEST

90

°

0

Direction of Front Operation

Handle Type

Direction of Right Side Operation

Door Drilling Layout

Ø78

70

44

0.78

4 Ø 0.27

0.55

Ø 1.46

4 Ø 7

Ø 37

20

20

14

0.55
14

0.78

I

3.50

(88.9)

2.16

(54.9)

0.86

(21.8)

1.06

(26.9)

4.68

(118.9)

1.55 

(39.4)

0.88

(22.3)

1.00

(25.4)

1.00

(25.4)

6.22

(158.0)

2.32

(58.9)

7.10

(180.3)

Ø0.50

(Ø12.7)

Ø0.28

(Ø7.1)

2.70

(68.6)

5.66

(143.8)

Flange Handle

FLH_

Acc.

Auxillary Contacts

Contact

Number of

Continuous

Voltage

Max Number of Aux

Part

Type

Contacts

Amp Rating

Rating

Contacts per Switch

Number

NO

1

10A

600Vac

4

BAC05

NC

1

10A

600Vac

4

BAC06

and …

A

UX

C

ONT

ACTS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—60A

Standard Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

394

For a Complete Assembly, Please Select:

Select for Standard 

Applications

Switch

Max Horsepower Rating

1-Phase

3-Phase

DC*

Amp

Fuse

Number

220/

220/

440/

600

125

250

Wire

Wire

Part

Rating

Class of Poles SCCR 240Vac

240Vac 480Vac Vac

Vdc Vdc

Size

Type

Number

60

J

2

200kA

10

-

-

-

5

10

#12-10 Sol

75°C Cu

RDF60J-2

#12-1 Str

60

J

3

200kA

-

15

30

50

5

10

#12-10 Sol

75°C Cu

RDF60J-3

#12-1 Str

60

J

4

200kA

-

15

30

50

5

10

#12-10 Sol

75°C Cu

RDF60J-4

#12-1 Str

* DC Ratings use two poles in series.

Direct Mount Handle - 

mounts directly to switch, no shaft required

For Switch

Test

Part

Part Number

Color

Function

Padlockable

Number

All Switches

Black

Y

Y

DIR-07

External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 12

Black

N

Y

Y

H12-03B

1, 3R, 12

Red/Yellow

N

Y

Y

H12-03R

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-06B

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-06R

1, 3R, 4, 4X, 12

Black

Y

Y

Y

H4X-06TB

1, 3R, 4, 4X, 12

Red/Yellow

Y

Y

Y

H4X-06TR

Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-06BHD

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-06RHD

External Right Side Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

N/A

H4X-06SB

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

N/A

H4X-06SR

Shafts for Pistol Handles

Length

Mounting Depth

Part

in (mm)

(X) in (mm)

Number

7.9 (200)

5.30~9.06 (135~230)

SH5-200

12.6 (320)

5.30~13.78 (135~350)

SH5-320

15.7 (400)

5.30~16.93 (135~430)

SH5-400

Flange Handle

(1) 

- requires shaft operated mechanism or cable operated mechanism + cable

NEMA

Flange

Test

Part

Type

Style

Function

Padlockable

Defeatable

Number

1, 3R, 4, 12

Standard

N

Y

Y

FLH1

1, 3R, 4, 4X, 12

Chrome Plated

N

Y

Y

FLH2

Shaft Operated Flange Mechanism

(2)

- includes shaft

For Enclosure Depth

Part

in (mm)

Number

6~24 (152~613)

FLRM

Cable Operated Flange Mechanism and Cable

- must select Mechanism

(3)

and

Cable

(4)

Part

Item / Length

Number

Cable Mechanism

FLCM

36” (900mm) Cable

FLC36

60” (1500mm) Cable

FLC60

120” (3000mm) Cable

FLC120

+

or

(1)

(2)

(3)

(4)

X

S

WITCH

H

ANDLE

or

or

+

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—60A

Standard Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

395

Disconnect

Switches

NFPA Through the Door Handle Kit

- to be used with front pistol handle

Test

Part

Color

Function

Padlockable

Defeatable

Number

Red

N

Y

N

H79-2

Dimensions – in (mm)

7.32

186

5.87

149.3

1.41

36

1.46
37.2

4.81

122.2

1.41

36

6.77

172

5.23

133

3.66

92.96

1.57

40

5.31

135

1.79
45.5

Direct Mount Handle

DIR-07

External Front and Right Side Pistol Handle

H4X-06__
H12-03__ 

0

I

90°

6

TEST

90

°

0

Ø78

1.77

4.92

Direction of Front Operation

Handle Type

Direction of Right Side Operation

Door Drilling Layout

Ø3.07

0.78

4 Ø 0.27

0.55

Ø 1.46

4 Ø 7

Ø 37

20

20

14

0.55
14

0.78

45

125

I

3.50

(88.9)

2.16

(54.9)

0.86

(21.8)

1.06

(26.9)

4.68

(118.9)

1.55 

(39.4)

0.88

(22.3)

1.00

(25.4)

1.00

(25.4)

6.22

(158.0)

2.32

(58.9)

7.10

(180.3)

Ø0.50

(Ø12.7)

Ø0.28

(Ø7.1)

2.70

(68.6)

5.66

(143.8)

Flange Handle

FLH_

Select

NFP

A H

ANDLE

or

Acc.

Auxillary Contacts

Contact

Number of

Continuous

Voltage

Max Number of Aux

Part

Type

Contacts

Amp Rating

Rating

Contacts per Switch

Number

NO

1

10A

600Vac

4

BAC05

NC

1

10A

600Vac

4

BAC06

and …

A

UX

C

ONT

ACTS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—100A

Standard Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

396

For a Complete Assembly, Please Select:

Select for Standard 

Applications

Switch

Max Horsepower Rating

1-Phase

3-Phase

DC*

Amp

Fuse

Number

220/

220/

440/

600

125

250

Wire

Wire

Part

Rating

Class

of Poles SCCR

240Vac 240Vac

480Vac

Vac Vdc Vdc

Size

Type

Number

100

J

2

200kA

10

-

-

-

7.5

20

#12-10 Sol

75°C Cu

RDF100J-2

#12-1 Str

100

J

3

200kA

-

30

60

75

7.5

20

#12-10 Sol

75°C Cu

RDF100J-3

#12-1 Str

100

J

4

200kA

-

30

60

75

7.5

20

#12-10 Sol

75°C Cu

RDF100J-4

#12-1 Str

* DC Ratings use two poles in series.

Direct Mount Handle - 

mounts directly to switch, no shaft required

For Switch

Test

Part

Part Number

Color

Function

Padlockable

Number

All Switches

Black

Y

Y

DIR-07

External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 12

Black

N

Y

Y

H12-03B

1, 3R, 12

Red/Yellow

N

Y

Y

H12-03R

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-06B

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-06R

1, 3R, 4, 4X, 12

Black

Y

Y

Y

H4X-06TB

1, 3R, 4, 4X, 12

Red/Yellow

Y

Y

Y

H4X-06TR

Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-06BHD

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-06RHD

External Right Side Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

N/A

H4X-06SB

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

N/A

H4X-06SR

Shafts for Pistol Handles

Length

Mounting Depth

Part

in (mm)

(X) in (mm)

Number

7.9 (200)

5.30~9.06 (135~230)

SH5-200

12.6 (320)

5.30~13.78 (135~350)

SH5-320

15.7 (400)

5.30~16.93 (135~430)

SH5-400

Flange Handle

(1) 

- requires shaft operated mechanism or cable operated mechanism + cable

NEMA

Flange

Test

Part

Type

Style

Function

Padlockable

Defeatable

Number

1, 3R, 4, 12

Standard

N

Y

Y

FLH1

1, 3R, 4, 4X, 12

Chrome Plated

N

Y

Y

FLH2

Shaft Operated Flange Mechanism

(2)

- includes shaft

For Enclosure Depth

Part

in (mm)

Number

6~24 (152~613)

FLRM

Cable Operated Flange Mechanism and Cable

- must select Mechanism

(3)

and

Cable

(4)

Part

Item / Length

Number

Cable Mechanism

FLCM

36” (900mm) Cable

FLC36

60” (1500mm) Cable

FLC60

120” (3000mm) Cable

FLC120

+

(1)

(2)

(3)

(4)

X

or

S

WITCH

H

ANDLE

or

or

+

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—100A

Standard Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

397

Disconnect

Switches

7.32

186

5.87

149.3

1.41

36

1.46
37.2

4.81

122.2

1.41

36

6.77

172

5.23

133

3.66

92.96

Dimensions – in (mm)

1.57

40

5.31

135

1.79
45.5

Direct Mount Handle

DIR-07

External Front & Right Side Pistol Handle

H4X-06__
H12-03__ 

0

I

90

°

65°

TEST

90°

0

Ø78

1.77

4.92

Direction of Front Operation

Handle Type

Direction of Right Side Operation

Door Drilling Layout

Ø3.07

0.78

4 Ø 0.27

0.55

Ø 1.46

4 Ø 7

Ø 37

20

20

14

0.55
14

0.78

45

125

I

3.50

(88.9)

2.16

(54.9)

0.86

(21.8)

1.06

(26.9)

4.68

(118.9)

1.55 

(39.4)

0.88

(22.3)

1.00

(25.4)

1.00

(25.4)

6.22

(158.0)

2.32

(58.9)

7.10

(180.3)

Ø0.50

(Ø12.7)

Ø0.28
(Ø7.1)

2.70

(68.6)

5.66

(143.8)

Flange Handle

FLH_

NFPA Through the Door Handle Kit

- to be used with front pistol handle

Test

Part

Color

Function

Padlockable

Defeatable

Number

Red

N

Y

N

H79-2

Select

NFP

A H

ANDLE

or

Acc.

Auxillary Contacts

Contact

Number of

Continuous

Voltage

Max Number of Aux

Part

Type

Contacts

Amp Rating

Rating

Contacts per Switch

Number

NO

1

10A

600Vac

4

BAC05

NC

1

10A

600Vac

4

BAC06

A

UX

C

ONT

ACTS

and …

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—200 & 400A

Standard Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

398

For a Complete Assembly, Please Select:

Select for Standard 

Applications

Switch

Max Horsepower Rating

1-Phase

3-Phase

DC*

Amp

Fuse

Number

220/

220/

440/

600

125

250

Part

Rating

Class

of Poles

SCCR

240Vac

240Vac

480Vac

Vac

Vdc

Vdc

Number

200

J

2

200kA

10

-

-

-

-

-

RDF200J-2

200

J

3

200kA

-

60

125

150

-

-

RDF200J-3

200

J

4

200kA

-

60

125

150

-

-

RDF200J-4

400

J

2

200kA

10

-

-

-

20

50

RDF400J-2

400

J

3

200kA

-

125

250

350

20

50

RDF400J-3

400

J

4

200kA

-

125

250

350

20

50

RDF400J-4

* DC Ratings use two poles in series.

Terminal Lug Kit

Switch

Number

Lugs

Part

Amp Rating

of Poles

Per Kit

Wire Range

Wire Type

Number

200

2

2

#6-300MCM

75°C Cu/Al

LUG1-2

200

3

3

#6-300MCM

75°C Cu/Al

LUG1-3

200

4

4

#6-300MCM

75°C Cu/Al

LUG1-4

400

2

2

#4-600MCM or

75°C Cu/Al

LUG2-2

Dual 1/0-250MCM

400

3

3

#4-600MCM or

75°C Cu/Al

LUG2-3

Dual 1/0-250MCM

400

4

4

#4-600MCM or

75°C Cu/Al

LUG2-4

Dual 1/0-250MCM

Direct Mount Handle - 

mounts directly to switch, no shaft required

For Switch

Test

Part

Part Number

Color

Function

Padlockable

Number

All Switches

Black

Y

Y

DIR-07

External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 12

Black

N

Y

Y

H12-03B

1, 3R, 12

Red/Yellow

N

Y

Y

H12-03R

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-06B

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-06R

1, 3R, 4, 4X, 12

Black

Y

Y

Y

H4X-06TB

1, 3R, 4, 4X, 12

Red/Yellow

Y

Y

Y

H4X-06TR

Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-06BHD

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-06RHD

External Right Side Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

N/A

H4X-06SB

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

N/A

H4X-06SR

Shafts for Pistol Handles

Length

Mounting Depth

Part

in (mm)

(X) in (mm)

Number

7.9 (200)

200A: 5.70-9.06 (145-230)

SH5-200

400A: 7.87-10.24 (200-260)

12.6 (320)

200A: 5.70-13.78 (145-350)

SH5-320

400A: 7.87-16.93 (200-380)

15.7 (400)

200A: 5.70-16.93 (145-430)

SH5-400

400A: 7.87-18.10 (200-460)

+

+

X

or

S

WITCH

+ L

UGS

H

ANDLE

or

+

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—200 & 400A

Standard Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

399

Disconnect

Switches

Select for Standard 

Applications

Flange Handle

(1)

200A Only

- requires shaft operated mechanism 

or

cable operated mechanism + cable

NEMA

Flange

Test

Part

Type

Style

Function

Padlockable

Defeatable

Number

1, 3R, 4, 12

Standard

N

Y

Y

FLH1

1, 3R, 4, 4X, 12

Chrome Plated

N

Y

Y

FLH2

Shaft Operated Flange Mechanism

(2)

200A Only

- includes shaft

For Enclosure Depth

Part

in (mm)

Number

6~24 (152~613)

FLRM

Cable Operated Flange Mechanism and Cable

200A Only

- must select Mechanism

(3)

and

Cable

(4)

Part

Item

Number

Cable Mechanism

FLCM

36” (900mm) Cable

FLC36

60” (1500mm) Cable

FLC60

120” (3000mm) Cable

FLC120

(1)

(2)

(3)

(4)

NFPA Through the Door Handle Kit

- to be used with front pistol handle

Use with

Test

Part

Switch

Color

Function

Padlockable

Defeatable

Number

RDF200J-_

Red

N

Y

N

H79-2

RDF400J-_

Red

N

Y

N

H79-3

Auxillary Contacts

Contact

Number of 

Continuous

Voltage

Max Number of Aux

Part

Type

Contacts

Amp Rating

Rating

Contacts per Switch Part Number

Number

NO

1

10A

600Vac

RDF200J-__: 4

BAC05

NC

1

10A

600Vac

RDF400J-__: 8

BAC06

Terminal Shrouds

- includes terminal shroud for lineside or loadside

Switch Amp

Number

Part

Rating

of Poles

Number

200

2

TSH8-2TB

200

3

TSH8-3TB

200

4

TSH8-4TB

400

2

TSH9-2TB

400

3

TSH9-3TB

400

4

TSH9-4TB

7.72

196.2

6.61

168

6.18

157

1.41

36

5.11

130

1.96

50

5.28

134.2

6.50

165.2

7.67

195

1

1.46

291.3

7.08

180

4.37

111.1

10.19

 

(3P)

 

-

 

12.79

 

(4P)

259

 

(3P)

 

-

 

325

 

(4P)

2.59

66

2.59

66

3.26

83

0.98
24.9

2.95

75

2.95

75

9.44

240

15.35

390

7.97

202.5

3.98

101.25

3.98

101.25

Dimensions – in (mm)

• RDF200J-3

• RDF400J-3

Accessories

A

UX

C

ONT

ACTS

S

HROUDS

H

ANDLE

or

or

and …

and …

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—200 & 400A

Standard Class J

Visit us on the web at 

www.cooperbussmann.com/Disconnects

400

External Front & Right Side Pistol Handle

H4X-06__
H12-03__ 

0

I

90

°

65°

TEST

90°

0

Ø78

1.77

4.92

Direction of Front Operation

Handle Type

Direction of Right Side Operation

Door Drilling Layout

Ø3.07

0.78

4 Ø 0.27

0.55

Ø 1.46

4 Ø 7

Ø 37

20

20

14

0.55
14

0.78

45

125

I

1.57

40

5.31

135

1.79
45.5

Direct Mount Handle

DIR-07

Terminal Lugs

200A

LUG1-__

400A

LUG2-__

1.52
38.8

1

25

1.12

28.6

0.45

Ø11.6

0.46

11.68

0.25

6.35

2.8

71.5

Ø 0.4
Ø 4.7

1.3

35

1.8

46

0.44

11

.1

3

0.63

15.88

3.50

(88.9)

2.16

(54.9)

0.86

(21.8)

1.06

(26.9)

4.68

(118.9)

1.55 

(39.4)

0.88

(22.3)

1.00

(25.4)

1.00

(25.4)

6.22

(158.0)

2.32

(58.9)

7.10

(180.3)

Ø0.50

(Ø12.7)

Ø0.28

(Ø7.1)

2.70

(68.6)

5.66

(143.8)

Flange Handle

FLH_

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

Visit us on the web at 

www.cooperbussmann.com/Disconnects

401

Disconnect

Switches

Open & Enclosed Rotary Disconnect Switches

In-Stock and Ship Within 24 Hours

The Bussmann 

QuikShip Everyday Service

ensures the most common open and
enclosed rotary disconnect switches 

ship

within 24 hours

to help you meet project

timelines.

Contact your Bussmann representative for
details.

www.cooperbussmann.com/Disconnects

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—600 & 800A

Standard Class J & Class L

Visit us on the web at 

www.cooperbussmann.com/Disconnects

402

For a Complete Assembly, Please Select:

Select for Standard 

Applications

Switch

Max Horsepower Rating, 3-Phase

Amp

Fuse

Number

220/

440/

Part

Rating

Class of Poles

SCCR

240Vac

480Vac

600Vac

Number

600

J

2

200kA

-

-

-

RDF600J-2

600

J

3

200kA

200

400

500

RDF600J-3

600

J

4

200kA

200

400

500

RDF600J-4

800

L

2

200kA

-

-

-

RDF800L-2

800

L

3

200kA

200

500

500

RDF800L-3

800

L

4

200kA

200

500

500

RDF800L-4

Terminal Lug Kit

Switch

Number

Lugs

Part

Amp Rating

of Poles

Per Kit

Wire Range

Wire Type

Number

600-800

2

2

(2) #2-600MCM

75°C Cu/Al

LUG5-2

600-800

3

3

(2) #2-600MCM

75°C Cu/Al

LUG5-3

600-800

4

4

(2) #2-600MCM

75°C Cu/Al

LUG5-4

Direct Mount Handle - 

mounts directly to switch, no shaft required

For Switch

Test

Part

Part Number

Color

Function

Padlockable

Number

All Switches

Black

Y

Y

DIR-08

+

or

+

NFPA Through the Door Handle Kit

- to be used with  front pistol handle

For Switch

Test

Part

Part Number

Color

Function

Padlockable

Defeatable

Number

All Switches

Red

N

Y

N

H79-4

Auxillary Contacts

Contact

Number of 

Continuous

Voltage

Max Number of Aux

Part

Type

Contacts

Amp Rating

Rating

Contacts per Switch

Number

NO

1

10A

600Vac

8

BAC05

NC

1

10A

600Vac

8

BAC06

Terminal Shrouds

- includes terminal shroud for lineside or loadside

Switch Amp

Number

Part

Rating

of Poles

Number

600-800

2

TSH10-2TB

600-800

3

TSH10-3TB

600-800

4

TSH10-4TB

Accessories

A

UX

C

ONT

ACTS

S

HROUDS

S

WITCH

+ L

UGS

H

ANDLE

or

or

External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-07B

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-07R

Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-07BHD

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-07RHD

Shafts for Pistol Handles

Length

Mounting Depth

Part

in (mm)

(X) in (mm)

Number

7.9 (200)

10.63~11.97 (270~304)

SH7-200

12.6 (320)

10.63~16.69 (270~424)

SH7-320

15.7 (400)

10.63~19.84 (270~504)

SH7-400

X

+

and …

and …

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Fused Rotary Disconnect Switches—600 & 800A

Standard Class J & Class L

Visit us on the web at 

www.cooperbussmann.com/Disconnects

403

Disconnect

Switches

9.84

250

6.10

155

3.12

79.5

0.27

7

2.32

59

14.96

380

Fuse Cover Fully Open

min 10.43

min 265

Ø 0.51

Ø13

0.43

11

11.18 (3P) -  14.88 (4P)

284 (3P) -  378 (4P)

65

34

2.56

1.34

2

51

0.35

9

3.7

3.7

94

14.33 (3P) - 18.03 (4P) 

364 (3P) - 458 (4P) 

94

fix 9.84 fix 250

5

126.5

11

.8

1

18.54 471

260

10.23

300

3.36 85.5

3.36 85.5

7

0.27

0.27

7

11.81 300

90

3.54

18.58

472

Dimensions – in (mm)

• RDF600J-3

• RDF800L-3

External Front Pistol Handle

H4X-07__

61

210

90°

I

0

Direction of Front Operation

Handle Type

Door Drilling Layout

Ø3.07

Ø78

0.78

4 Ø 0.27

0.55

Ø 1.46

4 Ø 7

Ø 37

20

20

14

0.55
14

0.78

60

2.36

85

3.35

190

7.48

Direct Mount Handle

DIR-08

Terminal Lugs

600 to 800A

LUG5-__

3.15

80

1.49 38

2.87 73

0.40

Ø10.2

3.76

95.5

0.64 16.2

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

Visit us on the web at 

www.cooperbussmann.com/Disconnects

404

UL 98 Non-Fused Rotary Disconnect Switches—30 to 1200A

QuikShip Everyday Service ships the
most common part numbers within
24 hours. Contact your Bussmann 
representative for details.

Description

Bussmann UL 98 non-fused rotary disconnect switches are

versatile switches that “break” and “make” power circuits ON

and OFF load.

Features

• Make and break power under load

• Up to 200kA SCCR

• DIN-Rail or panel mount (30-100A)

• Disconnect switches are front, right side and direct 

handle operable (30-100A)

• Finger-safe (30-100A)

• Fully visualized breaking (100-1200A)

Agency Information

• UL98, Guide WHTY, File E155130

• CSA 22.2 No. 4, File 257020

• Conforms with IEC 60947-3

Online Resources

Visit 

www.cooperbussmann.com/Disconnects

for:

• CAD Drawings

• Instruction Sheets

• UL Information

Related Cooper Bussmann Products

Fuse Blocks

Data Sheet #

Modular Knifeblade Fuse Blocks 100-600A

3192

Fuses Holders

CH Series Class CC, Midget & 10x38 0-30A 3185

Finger-Safe Optima Series 0-30A

1102

Optima™ Protection Modules 0-30A

1109

CH Series Class J 0-60A

2144

Part Number

3-Pole

RD30-3

RD60-3

RD100-3

RD100-3-SCCR

RD200-3

RD400-3

RD600-3

RD800-3

RD1000-3

RD1200-3

4-Pole

RD200-4

RD400-4

RD600-4

RD800-4

RD1000-4

RD1200-4

Thermal Current I

th

@ 40°C (A)

30

60

100

Rated insulation voltage U

i

(V)

800

800

800

1000

1000

1000

1000

Rated impulse withstand voltage U

imp

(kV)

8

8

8

12

12

12

12

Rated Operation Currents Ie (A)

Load Duty Category

Rated Voltage

(1)

(1)

(1)

(1)

(1)

(1)

(1)

400Vac

AC-22 A

32

63

100

630

800

1000

1200

400Vac

AC-23 A

32

63

100

630

800

1000

1000

690Vac

AC-22 A

32

63

80

500

630

630

630

690Vac

AC-23 A

32

63

63

200

400

400

400

Operational Power (Vac) in AC-23 (kW)

400V w/o prebreak AC 

(1)(2)

15

30

45

355

450

560

560

500V w/o prebreak AC 

(1)(2)

15

30

45

450

560

560

560

690V w/o prebreak AC 

(1)(2)

18.5

30

45

185

400

400

400

Overload Capacity (U

e

415Vac)

Rated short-time 
making capacity Icm(kA peak) 

(3)

12

12

12

48

75

48

75

Fuse Protected Short-Circuit Withstand 

(kA rms prospective)

Short-Circuit Current (kA) 

(3)

50

50

25

100

100

100

100

Associated Fuse Rating (A) 

(3)

32

63

100

630

800

1000

1250

Connection

Minimum Cu cable cross section (mm

2

)

2.5

2.5

10

2x150

2x185

2x240

Minimum Cu busbar section (mm

2

)

2x30x5

2x40x5

2x50x5

2x60x5

Maximum Cu cable section (mm

2

)

70

70

70

(1) A/B: Category with index A = frequent operation; category with index B = infrequent operation.

(2) The power value is given for information only; the current values vary from one manufacturer to another.

(3) For a rated operating voltage, U

e

= 400Vac.

IEC Electrical Specifications

RD30-3

RD200-3

RD600-3

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Non-Fused Rotary Disconnect Switches—30 to 1200A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

405

Disconnect

Switches

Part Number

3-Pole

RD30-3

RD60-3

RD100-3

RD100-3-SCCR

RD200-3

RD400-3

RD600-3

RD800-3

RD1000-3

RD1200-3

4-Pole

RD200-4

RD400-4

RD600-4

RD800-4

RD1000-4

RD1200-4

UL Standard

UL 98

UL 98

UL 98

UL 98

UL 98

UL 98

UL 98

UL 98

UL 98

UL 98

Max Ampacity

30A

60A

100A

100A

200A

400A

600A

800A

1000A

1200A

Switch Type

Compact

Compact

Compact

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Handle Operation

Front/Side

Front/Side

Front/Side

Front

Front

Front

Front

Front

Front

Front

UL Electrical Ratings

Max Voltage (AC)

600Vac

600Vac

600Vac

600Vac

600Vac

600Vac

600Vac

600Vac

600Vac

600Vac

Max Voltage (DC)

250Vdc

250Vdc

250Vdc

Maximum AC Horsepower Ratings

1-Phase, 120Vac

2

3

5

1-Phase, 240Vac

5

10

10

10

10

3-Phase, 240Vac

10

20

20

30

75

125

200

200

200

200

3-Phase, 480Vac

20

40

50

75

150

250

400

500

500

500

3-Phase, 600Vac

25

50

50

100

200

350

350

500

500

500

DC Horsepower Ratings

125Vdc

20

250Vdc

50

Electrical Characteristics

SCCR with Fuse

100kA

100kA

25kA/100kA*

200kA

200kA

200kA

200kA

100kA

100kA

100kA

Fuse Class

J

J

J

J

J

J

J

L

L

L

Max. Fuse Rating

30A

60A

100A

100A

200A

400A

600A

800A

1000A

1200A

Terminal Lugs/Kits

Integral

Integral

Integral

Lug Mounting Torque - Lb-In (N•m)

-

-

-

160 (18)

160 (18)

LUG2-_ 310 (35)

310 (35)

310 (35)

310 (35)

310 (35)

LUG3-_ 398 (45)

Wire Type

75°C Cu

75°C Cu

75°C Cu

75°C Cu/Al

75°C Cu/Al

75°C Cu/Al

75°C Cu/Al

75°C Cu/Al

75°C Cu/Al

75°C Cu/Al

Wire Range & Torque - Lb-In (N•m)

Solid

#12-10

#12-10

#12-10

35.4 (4)

35.4 (4)

35.4 (4)

Stranded

#10-1

#10-1

#10-1

#6-300MCM

#6-300MCM

LUG2-_ #4-600MCM

(2) #2-600MCM

(4) #2-600MCM (4) #2-600MCM

(4) #2-600MCM

35.4 (4)

35.4 (4)

35.4 (4)

275 (31)

275 (31)

550 (62)

375 (42.4)

375 (42.4)

375 (42.4)

375 (42.4)

1/0

1/0

1/0

Dual 1/0-250MCM

39.8 (4.5)

39.8 (4.5)

39.8 (4.5)

550 (62)

2/0

2/0

2/0

LUG3-_:(2) #6-2

44.3 (5)

44.3 (5)

44.3 (5)

200 (22.6)

(2) #1-350MCM

375 (42.4)

Mechanical Characteristics

Endurances/Cycles

10,000

10,000

10,000

10,000

8000

6000

6000

3500

3500

3500

Physical Characteristics

Dimensions

See drawings on product pages

Weight - Lbs (KG)

3-Pole

1.3 (0.6)

1.3 (0.6)

1.3 (0.6)

4.2 (1.91)

4.2 (1.91)

10.0 (4.6)

18.1 (8.2)

19.6 (8.9)

19.6 (8.9)

19.6 (8.9)

4-Pole

5.0 (2.3)

12.3 (5.6)

23.9 (10.9)

25.3 (11.5)

25.3 (11.5)

25.3 (11.5)

Environmental

Operating Temperature

-20°C to 70°C

-20°C to 70°C -20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

Flammability Rating

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

Accessories

Lug Kit Part #

3-Pole

Integral

Integral

Integral

4-Pole

Handles

NEMA 1, 3R, 12

NEMA 1, 3R, 4, 4X, 12

Direct

Front Pistol

Front or Side Selector

Shaft c/s - mm

5x5

5x5

5x5

10x10

10x10

10x10

12x12

12x12

12x12

12x12

Shaft Guide

••

Shrouds

Additional Pole Accessory

Auxiliary Contacts

NO + NC

(2) NO

• Available, see product page for details and part numbers.

— Not available.

* 25kA @ 600Vac, 100kA @ 480Vac.

Specifications

RD30-3

RD200-3

RD600-3

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Non-Fused Rotary Disconnect Switches—30, 60 and Compact 100A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

406

For a Complete Assembly, Please Select:

Select for Standard 

Applications

Switch

Max Horsepower Rating

Switch

1-Phase

3-Phase

Amp

No. of

120

220/

220/

440/

600

Wire

Wire

Part

Rating

Poles

SCCR

Vac

240Vac

240Vac 480Vac Vac

Size

Type

Number

30

3

100kA

2

5

10

20

25

#10-2/0 Str

75°C Cu

RD30-3

#12-10 Sol

60

3

100kA

3

10

20

40

50

#10-2/0 Str

75°C Cu

RD60-3

#12-10 Sol

100

3

25/100kA*

5

10

20

50

50

#10-2/0 Str

75°C Cu

RD100-3

#12-10 Sol

* 100kA @480Vac, 25kA @ 600Vac.

Direct Mount Handle - 

mounts directly to switch, no shaft required

For Switch

Test

Part

Part Number

Color

Function

Padlockable

Number

All Switches

Black

N

Y - On Switch

DIR-02

External Front or Right Side Operated Selector Handles - 

shaft required

NEMA

Handle

Test

Part

Type

Color

Length

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

Short

N

Y

Y

H4X-01B

(1)

1, 3R, 4, 4X, 12

Red/Yellow

Short

N

Y

Y

H4X-01R

(1)

1, 3R, 4, 4X, 12

Black

Long

N

Y

Y

H4X-02B

(2)

1, 3R, 4, 4X, 12

Red/Yellow

Long

N

Y

Y

H4X-02R

(2)

Shafts for Selector Handles

Length

Mounting Depth

Part

in (mm)

(X) in (mm)

Number

5.9 (150)

3.50~7.60 (89~193)

SH4-150

7.9 (200)

3.50~9.50 (89~241)

SH4-200

12.6 (320)

3.50~14.9 (89~378)

SH4-320

Shaft Guide

Part
Number

Required for 12.6” (320mm) long shafts, optional for other lengths

SH-GUIDE1

Auxillary Contacts

Contact

Number of 

Continuous

Voltage

Max Number of Aux

Part

Type

Contacts

Amp Rating

Rating

Contacts per Switch

Number

NO + NC

1 of each

10A

240Vac

4

BAC01

NO

2

10A

240Vac

4

BAC02

+

+

Terminal Shrouds

- includes terminal shroud for both lineside and loadside

Switch Amp

Number

Location on

Part

Rating

of Poles

Switch

Number

All Switches

1 (for switched 4

th

pole)

Lineside and Loadside

TSH3-1TB

All Switches

3

Lineside and Loadside

TSH3-3TB

Switched 4

th

Pole

- converts 3-pole switch to 4-pole

Switch Amp

Part

Rating

Number

30

POLE98-30

60

POLE98-60

100

POLE98-100

Auxiliary Contact Configurations

Possible 4

th

Pole Configurations

X

Accessories

A

UX

C

ONT

ACTS

S

HROUDS

S

W

. 4

TH

P

OLE

S

WITCH

H

ANDLES

or

+

and …

and …

and …

(2)

(1)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Non-Fused Rotary Disconnect Switches—30, 60 and Compact 100A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

407

Disconnect

Switches

Dimensions - in (mm)

Direct Handle Operation

75

64

53

0.24
6

124.6

131.4

189

26

78

8.8

8.8

26

26

26

M5

2.95

2.52

2.09

4.91

0.35

0.35

1.02

1.02

1.02

5.17

7.44

1.02

3.07

2

1

2

1

36

100 min./372 max.

81

64

2.08

0.26

50.6

1.42

3.94 min./14.65 max.

3.19

2.52

1.99

53

6

2.79

71

13

124.6

131.4

189

26

78

36

8.8

8.8

26

26

26

M5

30 min./201 max.

3.07

1.02

0.51

1.18 min./7.91 max.

1.42

4.90

0.34

0.34

1.02

1.02

1.02

5.17

7.44

2.79

71

2

1

2

1

External Front Operation

External Right Side Operation

13.5

Ø 22.5

3

40

4 Ø 7

Ø 31

28

With Mounting Nut

With 4 Mounting Screws

H4X-01_

Door Drilling Layouts

Handle Type

0

I

90

°

Direction of Front Operation

0

I

90

°

Direction of Right Side Operation

1.57

4 Ø 0.27

1.10

Ø 1.22

0.11

0.53

Ø 0.88

Ø3.07 

1.42

2.79

Ø78 

36

71

Ø78 

37

88

Ø3.07 

1.45

3.46

H4X-02_

1. Position for 1 switched 4

th

pole (1 per device max.) or 1 auxiliary contact.

2. Position for 1 auxiliary contact only.

Note: Maximum of 4 auxiliary contacts, or 3 auxiliary contacts + one switched 4

th

pole.

External Front or Right Side Operated Selector Handle

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Non-Fused Rotary Disconnect Switches—100, 200 and 400A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

408

For a Complete Assembly, Please Select:

Select for Standard 

Applications

Switch

Max Horsepower Rating

Switch

1-Phase

3-Phase

Amp

No. of

220/

220/

440/

600

Part

Rating

Poles

SCCR

240Vac

240Vac

480Vac

Vac

Number

100

3

200kA

10

30

75

100

RD100-3-SCCR

200

3

200kA

10

75

150

200

RD200-3

200

4

200kA

10

75

150

200

RD200-4

400

3

200kA

-

125

250

350

RD400-3

400

4

200kA

-

125

250

350

RD400-4

Terminal Lug Kit

Switch

No. of 

Lugs

Part

Amp Rating

Poles

Per Kit

Wire Range

Wire Type

Number

100-200

2

2

#6-300MCM

75°C Cu/Al

LUG1-2

100-200

3

3

#6-300MCM

75°C Cu/Al

LUG1-3

100-200

4

4

#6-300MCM

75°C Cu/Al

LUG1-4

400

2

2

#4-600MCM or Dual 1/0-250MCM

75°C Cu/Al

LUG2-2

400

3

3

#4-600MCM or Dual 1/0-250MCM

75°C Cu/Al

LUG2-3

400

4

4

#4-600MCM or Dual 1/0-250MCM

75°C Cu/Al

LUG2-4

400

2

2

(2) #6-350MCM

75°C Cu/Al

LUG3-2

400

3

3

(2) #6-350MCM

75°C Cu/Al

LUG3-3

400

4

4

(2) #6-350MCM

75°C Cu/Al

LUG3-4

Direct Mount Handle - 

mounts directly to switch, no shaft required

For Switch

Test

Part

Part Number

Color

Function

Padlockable

Number

All Switches

Black

N

Y

DIR-03

External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 12

Black

N

Y

Y

H12-03B

1, 3R, 12

Red/Yellow

N

Y

Y

H12-03R

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-06B

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-06R

Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-06BHD

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-06RHD

Shafts for Pistol Handles

Length

Mounting Depth

Part

in (mm)

(X) in (mm)

Number

7.9 (200)

5.31~10.43 (135~265)

SH5-200

12.6 (320)

5.31~15.16 (135~385)

SH5-320

15.7 (400)

5.31~18.31 (135~465)

SH5-400

Shaft Guide

Part
Number

Required for 15.7” (400mm) long shafts, optional for other lengths

SH-GUIDE2

Auxillary Contacts

Contact

Number of

Continuous

Voltage

Max Number of Aux

Part

Type

Contacts

Amp Rating

Rating

Contacts per Switch

Number

NO + NC

1 of each

10.1A

125-250Vac

2

BAC03*

NO + NC

1 of each

10.1A

125-250Vac

2

BAC04*

NO + NC

1 of each

1A

125Vac

2

BAC11*

NO + NC

1 of each

1A

125Vac

2

BAC12*

* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.

+

+

+

X

Accessories

and …

A

UX

C

ONT

ACTS

S

WITCH

+ L

UGS

H

ANDLE

or

or

+

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Non-Fused Rotary Disconnect Switches—100, 200 and 400A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

409

Disconnect

Switches

Accessories

Terminal Shrouds

- includes terminal shroud for lineside or loadside

Switch Amp

Number

Location on

Part

Rating

of Poles

Switch

Number

100-200A

3

Lineside

TSH4-3T

100-200A

3

Loadside

TSH4-3B

100-200A

4

Lineside or Loadside

TSH4-4TB

400A

3

Lineside

TSH5-3T

400A

3

Loadside

TSH5-3B

400A

4

Lineside or Loadside

TSH5-4TB

Y

AC

KC

A

V

N

AA

H

Z

J1

U

R1

M

AD

T

F

C

1

R2

W

Switch Overall Terminal

Switch

Switch

Rating Dimen. Shrouds

Body

Mounting

Connection

(A)

C

AC

AD

F 3p.

F 4p.

H

J1 3p. J1 4p. K

M 3p. M 4p. N

R1

R2

T

U

V

W

Y

Z

AA

AC

100

3.72

10.1

3.05

7.09

9.06

4.22

2.17

4.13

1.8

6.3

8.27

5.31

0.35 0.27 1.97 0.98 1.18 0.43 0.14 1.35 6.3

0.6

(94.6)

(256)

(77.5) (180)

(230)

(107)

(55)

(105)

(45.6) (160) (210) (135) (9)

(7)

(50) (25)

(30) (11)

(3.5) (34.4) (160) (15)

200

3.72

10.1

3.05

7.09

9.06

4.22

2.17

4.13

1.8

6.3

8.27

5.31

0.35 0.27 1.97 0.98 1.18 0.43 0.14 1.35 6.3

0.6

(94.6)

(256)

(77.5) (180)

(230)

(107)

(55)

(105)

(45.6) (160) (210) (135) (9)

(7)

(50) (25)

(30) (11)

(3.5) (34.4) (160) (15)

400

4.92

16

4.15

9.05

11.4

6.53

2.95

5.31

2.65

8.26

10.6

7.67

0.35 0.27 2.56 1.77 1.97 0.43 0.2

2.08 10.2 0.8

(128)

(406)

(115)

(230)

(290)

(166)

(75)

(135)

(67.5) (210) (270) (195) (9)

(7)

(65) (45)

(50) (13)

(5)

(53)

(260) (20)

Dimensions - in (mm)

1.57

40

5.31

135

1.79
45.5

Direct Mount Handle

H4X-06__
H12-03__ 

65°

TEST

90

°

0

Ø78

1.77

4.92

Direction of Front Operation

Handle Type

Door Drilling Layout

Ø3.07

0.78

4 Ø 0.27

0.55

Ø 1.46

4 Ø 7

Ø 37

20

20

14

0.55
14

0.78

45

125

I

External Front Handle

Terminal Lugs

400A

LUG2-__

100 to 200A

LUG1-__

400A

LUG3-__

1.52
38.8

1

25

1.12

28.6

0.45

Ø11.6

0.46

11.68

0.25

6.35

2.8

71.5

Ø 0.4
Ø 4.7

1.3

35

1.8

46

0.44

11

.1

3

0.63

15.88

0.88

73.15

2.31

58.67

0.53

13.46

1.19

30.23

1.94 49.30

0.25
6.35

1.25

31.75

DIR-03

and …

S

HROUDS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Non-Fused Rotary Disconnect Switches—600, 800, 1000 and 1200A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

410

For a Complete Assembly, Please Select:

Select for Standard 

Applications

Switch

Max Horsepower Rating

Switch

3-Phase

DC*

Amp

No. of

220/

440/

600

125

250

Part

Rating

Poles

SCCR

240Vac

480Vac

Vac

Vdc

Vdc

Number

600A

3

200kA

240

400

350

20

50

RD600-3

600A

4

200kA

240

400

350

20

50

RD600-4

800A

3

100kA

200

500

500

-

-

RD800-3

800A

4

100kA

200

500

500

-

-

RD800-4

1000A

3

100kA

200

500

500

-

-

RD1000-3

1000A

4

100kA

200

500

500

-

-

RD1000-4

1200A

3

100kA

200

500

500

-

-

RD1200-3

1200A

4

100kA

200

500

500

-

-

RD1200-4

* DC Ratings use two poles in series.

Terminal Lug Kit

Switch

No. of 

Lugs

Lugs Required

Wire

Part

Amp Rating

Poles

Per Kit

per Pole

Range

Wire Type

Number

600

3

3

1

(2) #2-600MCM

75°C Cu/Al

LUG5-3

600

4

4

1

(2) #2-600MCM

75°C Cu/Al

LUG5-4

800-1200

3

6

2

(4) #2-600MCM

75°C Cu/Al

LUG6-6

800-1200

4

8

2

(4) #2-600MCM

75°C Cu/Al

LUG6-8

Direct Mount Handle - 

mounts directly to switch, no shaft required

For Switch

Test

Part

Part Number

Color

Function

Padlockable

Number

All Switches

Black

N

Y

DIR-04

External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-07B

(1)

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-07R

(1)

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-08B

(2)

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-08R

(2)

Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles - 

shaft required

NEMA

Test

Part

Type

Color

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-07BHD

(3)

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-07RHD

(3)

1, 3R, 4, 4X, 12

Black

N

Y

Y

H4X-08BHD

(4)

1, 3R, 4, 4X, 12

Red/Yellow

N

Y

Y

H4X-08RHD

(4)

Shafts for Pistol Handles

Length

Mounting Depth

Part

in (mm)

(X) in (mm)

Number

7.9 (200)

8.70~13.50 (221~343)

SH6-200

12.6 (320)

8.70~18.23 (221~463)

SH6-320

15.7 (400)

8.70~21.38 (221~543)

SH6-400

Shaft Guide

Part
Number

Required for 15.7” (400mm) long shafts, optional for other lengths

SH-GUIDE2

Auxillary Contacts

Contact

Number of 

Continuous

Voltage

Max Number of Aux 

Part

Type

Contacts

Amp Rating

Rating

Contacts per Switch

Number

NO + NC

1 of each

10.1A

125-250Vac

2

BAC03*

NO + NC

1 of each

10.1A

125-250Vac

2

BAC04*

NO + NC

1 of each

1A

125Vac

2

BAC11*

NO + NC

1 of each

1A

125Vac

2

BAC12*

* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.

+

or

+

+

X

(1)

(2)

(3)

(4)

Accessories

A

UX

C

ONT

ACTS

S

WITCH

+ L

UGS

H

ANDLE

or

+

and …

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Non-Fused Rotary Disconnect Switches—600, 800, 1000 and 1200A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

411

Disconnect

Switches

Accessories

Terminal Shrouds*

- includes terminal shroud for lineside or loadside

Switch Amp

Number

Location on

Part

Rating

of Poles

Switch

Number

600A

3

Lineside or Loadside

TSH6-3TB

600A

4

Lineside or Loadside

TSH6-4TB

800-1200A

3

Lineside or Loadside

TSH7-3TB

800-1200A

4

Lineside or Loadside

TSH7-4TB

* Shroud for lineside included with switch.

600A

Switch Terminal

Switch

Switch

Rating Shrouds

Body

Mounting

Connection

(A)

B

F 3p.

F 4p.

H

J 3p.

J 4p.

M 3p.

M 4p.

N

N1

N2

AA

Z

600

18.12

11

14.17

5.5

5

6.59

10.03

13.19

6.88

2.34

1.10

12.6

1.85 

(460)

(280)

(360)

(140)

(127.5)

(167.5)

(255)

(335)

(175)

(59.5)

(28)

(320)

(47)

800

18.12

14.64

19.37

5.5

6.83

9.19

13.66

18.38

6.88

2.34

1.10

13

1.85

(460)

(372)

(492)

(140)

(173.5)

(233.5)

(347)

(467)

(175)

(59.5)

(28)

(330)

(47)

1000

18.12

14.64

19.37

5.5

6.83

9.19

13.66

18.38

6.88

2.34

1.10

13

1.85

(460)

(372)

(492)

(140)

(173.5)

(233.5)

(347)

(467)

(175)

(59.5)

(28)

(330)

(47)

1200

18.12

14.64

19.37

5.5

6.83

9.19

13.66

18.38

6.88

2.34

1.10

13

1.85

(460)

(372)

(492)

(140)

(173.5)

(233.5)

(347)

(467)

(175)

(59.5)

(28)

(330)

(47)

800 to 1200A

H4X-07__

61

210

90

°

0

Direction of Front Operation

Handle Type

Door Drilling Layout

Ø3.07

Ø78

0.78

4 Ø 0.27

0.55

Ø 1.46

4 Ø 7

Ø 37

20

20

14

0.55
14

0.78

8.27

2.4

H4X-08__ 

2.36

13.78

Ø3.07

90

°

I

0

Ø78

350

60

I

Terminal Lugs

600 to 1200A

LUG5-__, LUG6-__

3.15

80

1.49 38

2.87 73

0.40

Ø10.2

3.76

95.5

0.64 16.2

60

2.36

85

3.35

190

7.48

Direct Mount Handle

DIR-04

External Front Pistol Handles

Dimensions - in (mm)

and …

S

HROUDS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 508 Non-Fused Rotary Disconnect Switches—16 to 80A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

412

Description

Bussmann UL 508 load break disconnect switches allow safe

control and safe disconnection of any motor application or to

isolate a circuit within the panel.

These disconnect switches are compact and offer a wide

variety of accessories like 4

th

poles, auxiliary contacts, door

mounting and 6/8-Pole kits.

Features

• Suitable as motor disconnect

• DIN-Rail or panel mount 

• Door mount option

• Disconnect switches are front, right side or 

direct handle operable

• Finger-safe

Agency Information

• UL508, Guide NLRV, File E155129

• CSA C22.2 No. 14, File 257020

• Conforms with IEC 60947-3

Online Resources

Visit 

www.cooperbussmann.com/Disconnects

for:

• CAD Drawings

• Instruction Sheets

• UL Information

Related Cooper Bussmann Products

Product

Data Sheet #

Fuses Blocks

Modular Knifeblade Fuse Blocks 100-600A

3192

Fuses Holders

CH Series Class CC, Midget & 10x38 0-30A 3185

Finger-Safe Optima Series 0-30A

1102

Optima™ Protection Modules 0-30A

1109

CH Series Class J 0-60A

2144

Part Number

RD16-3-508

RD25-3-508

RD40-3-508

RD63-3-508

RD80-3-508

Thermal Current I

th

at 40°C (A)

16

25

40

63

80

Rated insulation voltage U

i

(V)

800

800

800

800

800

Rated impulse withstand voltage U

imp

(kV)

8

8

8

8

8

Rated Operation Currents I

e

(A)

Load Duty Category

Rated Voltage

A/B 

(1)

A/B 

(1)

A/B 

(1)

A/B 

(1)

A/B 

(1)

500Vac

AC-22 A/AC-22 B

16/16

25/25

40/40

63/63

80/80

500Vac

AC-23 A/AC-23 B

16/16

25/25

25/25

63/63

63/63

690Vac

AC-21 A/AC-21 B

16/16

25/25

40/40

63/63

80/80

690Vac

AC-22 A/AC-22 B

16/16

25/25

32/40

40/63

63/80

690Vac

AC-23 A/AC-23 B

16/16

25/25

25/25

40/40

40/40

Operational Power in AC-23 (kW)

400Vac without prebreak AC 

(1)(2)

7.5

11

18.5

30

37

500Vac without prebreak AC 

(1)(2)

7.5

11

15

30

37

690Vac without prebreak AC 

(1)(2)

7.5

15

18.5

30

37

Overload Capacity (U

e

415 Vac)

Rated short-time withstand current 0.3 s. I

CW

(kA rms) 

(3)

2.5

2.5

2.5

3

3

Rated short-time making capacity I

cm

(kA  peak)  (3)

6

6

6

9

9

Fuse Protected Short-Circuit Withstand (kA rms Prospective)

Prospective short-circuit current (kA rms) 

(3)

50

50

50

50

50

Associated fuse rating (A) 

(3)

16

25

40

63

80

Connection

Minimum Cu cable cross section (mm

2

)

1.5

1.5

1.5

2.5

2.5

Maximum Cu cable section (mm

2

)

16

16

16

35

35

Tightening torque min/max (N•m)

2/2.2

2/2.2

2/2.2

3.5/3.85

3.5/3.85

(1) A/B: Category with index A = frequent operation; category with index B = infrequent operation.

(2) The power value is given for information only; the current values vary from one manufacturer to another.

(3) For a rated operating voltage, U

e

= 400Vac.

IEC Electrical Specifications

RD16-3-508

RD16-3-508 with 6-Pole Conversion Kit

QuikShip Everyday Service ships the
most common part numbers within
24 hours. Contact your Bussmann 
representative for details.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 508 Non-Fused Rotary Disconnect Switches—16 to 80A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

413

Disconnect

Switches

Part Number

RD16-3-508

RD25-3-508

RD40-3-508

RD63-3-508

RD80-3-508

UL Standard

UL 508

UL 508

UL 508

UL 508

UL 508

Max Ampacity

16A

25A

40A

63A

80A

Handle Operation

Front/Side

Front/Side

Front/Side

Front/Side

Front/Side

UL Electrical Ratings

Max Voltage (AC)

600Vac

600Vac

600Vac

600Vac

600Vac

Maximum Horsepower Ratings

3-Phase, 208Vac

3

7.5

7.5

15

15

3-Phase, 240Vac

5

7.5

7.5

20

20

3-Phase, 480Vac

10

15

20

40

40

3-Phase, 600Vac

10

20

25

40

40

Electrical Characteristics

SCCR with Fuse

65kA

65kA

10/65kA

50/65kA

50/65kA

Recommended Upstream
Fuse Class

J

J

J

J

J

Max. Fuse Rating

30A

30A

60/30A

100/60A

100/60A

Terminals

Integral

Integral

Integral

Integral

Integral

Wire Type

75°C Cu

75°C Cu

75°C Cu

75°C Cu

75°C Cu

Wire Range & Torque - Lb-IN (N•m)

Solid

Single

#14-10

#14-10

#14-10

#14-10

#14-10

26.5 (3)

26.5 (3)

26.5 (3)

31.1 (3.5)

31.1 (3.5)

Dual

#12

#12

#12

#12

#12

26.5 (3)

26.5 (3)

26.5 (3)

31.1 (3.5)

31.1 (3.5)

Stranded

Single

#14-4

#14-4

#14-4 #14-1

#14-1

26.5 (3)

26.5 (3)

26.5 (3)

31.1 (3.5)

31.1 (3.5)

Dual

#14-12

#14-12

#14-12

#10-6

#10-6

26.5 (3)

26.5 (3)

26.5 (3)

31.1 (3.5)

31.1 (3.5)

Mechanical Characteristics

Endurances/Cycles

10,000

10,000

10,000

10,000

10,000

Physical Characteristics

Dimensions - See drawings on product pages
Weight - Lb (KG)

0.5 (0.2)

0.5 (0.2)

0.5 (0.2)

0.7 (0.32)

0.7 (0.32)

Environmental

Operating Temperature

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

-20°C to 70°C

Flammability Rating

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

UL 94-V0

Accessories

Handles

Direct

DIR-01

DIR-01

DIR-01

DIR-01

DIR-01

Short Selector/NEMA 1, 3R, 4, 4X, 12

H4X-01B

H4X-01B

H4X-01B

H4X-01B

H4X-01B

H4X-01R

H4X-01R

H4X-01R

H4X-01R

H4X-01R

Long Selector/NEMA 1, 3R, 4, 4X, 12

H4X-02B

H4X-02B

H4X-02B

H4X-02B

H4X-02B

H4X-02R

H4X-02R

H4X-02R

H4X-02R

H4X-02R

Shafts - 5x5mm

5.9”/150mm

SH4-150

SH4-150

SH4-150

SH4-150

SH4-150

7.9”/200mm

SH4-200

SH4-200

SH4-200

SH4-200

SH4-200

12.6”/320mm

SH4-320

SH4-320

SH4-320

SH4-320

SH4-320

Shaft Guide

SH-GUIDE1

SH-GUIDE1

SH-GUIDE1

SH-GUIDE1

SH-GUIDE1

Door Mount Kit

DOOR-508

DOOR-508

DOOR-508

DOOR-508

DOOR-508

Shrouds/Switch Amps

1-Pole

TSH1-1TB

TSH1-1TB

TSH1-1TB

3-Pole (Loadside and Lineside)

TSH1-3TB

TSH1-3TB

TSH1-3TB

TSH2-3TB

TSH2-3TB

Switched 4

th

Pole/Switch Amps

POLE-16

POLE-25

POLE-40

Auxiliary Contacts

NO + NC (1 ea.)

BAC01

BAC01

BAC01

BAC01

BAC01

(2) NO

BAC02

BAC02

BAC02

BAC02

BAC02

AC Ratings

Volts

240Vac

240Vac

240Vac

240Vac

240Vac

Amps

10A

10A

10A

10A

10A

6-/8-Pole Conversion Kit 
Gangs two switches of same rating, 16-80A switch amps

KIT-6POLE

KIT-6POLE

KIT-6POLE

KIT-6POLE

KIT-6POLE

— Not available.

Specifications

RD16-3-508

RD16-3-508 with 6-Pole Conversion Kit

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 508 Non-Fused Rotary Disconnect Switches—16, 25, 40, 63 and 80A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

414

For a Complete Assembly, Please Select:

Select for Standard 

Applications

Switch

Switch

Max

Max Horsepower Rating, 3-Ph

Amp

No. of

SCCR

Class J

208

220/

440/

600

Part

Rating

Poles

@600V

Fuse

Vac

240Vac 480Vac

Vac

Wire Size

Wire Type

Number

#14-#10 Sol

16

3

65kA

30A

3

5

10

10

Dual #12 Sol

75°C Cu

RD16-3-508

#14-#4 Str

Dual #14-#12 Str

#14-#10 Sol

25

3

65kA

30A

7.5

7.5

15

20

Dual #12 Sol

75°C Cu

RD25-3-508

#14-#4 Str

Dual #14-#12 Str

#14-#10 Sol

40

3

10kA

60A

7.5

7.5

20

25

Dual #12 Sol

75°C Cu

RD40-3-508

65kA

30A

#14-#4 Str

Dual #14-#12 Str

#14-#10 Sol

63

3

50kA

100A

15

20

40

40

Dual #12 Sol

75°C Cu

RD63-3-508

65kA

60A

#14-#1 Str

Dual #10-#6 Str

#14-#10 Sol

80

3

50kA

100A

15

20

40

40

Dual #12 Sol

75°C Cu

RD80-3-508

65kA

60A

#14-#1 Str

Dual #10-#6 Str

Direct Mount Handle - 

mounts directly to switch, no shaft required

For Switch

Test

Part

Part Number

Color

Function

Padlockable

Number

All Switches

Black

N

Y - On Switch

DIR-01

External Front or Right Side Operated Selector Handles - 

shaft required

NEMA

Handle

Test

Part

Type

Color

Length

Function

Padlockable

Defeatable

Number

1, 3R, 4, 4X, 12

Black

Short

N

Y

Y

H4X-01B

(1)

1, 3R, 4, 4X, 12

Red/Yellow

Short

N

Y

Y

H4X-01R

(1)

1, 3R, 4, 4X, 12

Black

Long

N

Y

Y

H4X-02B

(2)

1, 3R, 4, 4X, 12

Red/Yellow

Long

N

Y

Y

H4X-02R

(2)

Shafts for Selector Handles

- required for 12.6” (320mm) shafts

Length

Mounting Depth

Part

in (mm)

(X) in (mm)

Number

5.9 (150)

3.50-7.60 (89-193)

SH4-150

7.9 (200)

3.50-9.50 (89-241)

SH4-200

12.6 (320)

3.50-14.9 (89-378)

SH4-320

Shaft Guide

Part
Number

Required for 12.6” (320mm) long shafts, optional for other lengths.

SH-GUIDE1

Door Mount Kit

- for mounting switch on the right side of the enclosure or directly on the enclosure door

using switch side operation shaft location. Kit includes a shaft. 

Order switch and selector handle separately

.

Switch

Part

Rating

Number

All Switches - kit includes shaft

DOOR-508

Auxillary Contacts

Contact

Number of 

Continuous

Voltage

Max Number of Aux

Part

Type

Contacts

Amp Rating

Rating

Contacts per Switch

Number

NO + NC

1 Ea

10A

240Vac

4

BAC01

NO

2

10A

240Vac

4

BAC02

+

+

+

(2)

(1)

Auxiliary Contact

Configurations

X

Acc.

A

UX

C

ONT

ACTS

S

WITCH

H

ANDLE

or

+

and …

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 508 Non-Fused Rotary Disconnect Switches—16, 25, 40, 63 and 80A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

415

Disconnect

Switches

Accessories

Switched 4

th

Pole

- converts 3-pole switch to 4-pole switch

Switch Amp

Part

Rating

Number

16

POLE-16

25

POLE-25

40

POLE-40

6-Pole Conversion Kit

- creates a 6-pole switch by ganging two 3-pole switches of equal rating

Switch Amp

Part

Rating

Number

All Switches

KIT-6POLE*

* Kit ships with a direct handle. If external handle is needed order a selector handle 

and 

shaft for the UL 508 Rotary Disconnect Switches.

Note: To create an 8-pole switch from 16 to 40 amp switches, use two 3-pole switches of equal ratings plus two switched 4

th

poles (part # POLE-_).

Terminal Shrouds

- includes terminal shroud for both lineside 

and

loadside

Switch Amp

Number

Location on

Part

Rating

of Poles

Switch

Number

16-40A

1 (for switched 4

th

pole)

Lineside and Loadside

TSH1-1TB

16-40A

3

Lineside and Loadside

TSH1-3TB

63-80A

3

Lineside and Loadside

TSH2-3TB

Switched 4

th

Pole 

Configurations.

Order switches separately.

Dimensions – in (mm)

Direct Handle Operation

External Front Operation

External Side Operation

Overall

Terminal Switch

Switch

Switch

Dimensions

Shroud

Body

Mounting

Connection

Rating (A)

D min

D max

E min

E max

AC

F

F1

G

J

M

N

T

16 to 40

1.18

9.25

3.94

14.64

4.33

1.77

0.59

2.67

0.59

1.18

2.95

0.59

(30)

(235)

(100)

(372)

(110)

(45)

(15)

(68)

(15)

(30)

(75)

(15)

63 to 80

1.18

9.25

3.93

14.64

4.33

2.06

0.69

2.99

0.69

1.38

3.35

0.69

(30)

(235)

(100)

(372)

(110)

(52.5)

(17.5)

(76)

(17.5)

(35)

(85)

(17.5)

2.67

F

T

M5

M

N

G

AC

2.52

0.24

1.97

2.95

F1

F1

0.35

2

1

2

1

75

64

6

50

68

8.8

8.8

0.35

J

2.68

F

T

M5

M

1.42

D

N

G

AC

E

1.42

3.19

2.52

0.23

1.96

1.99

F1

0.35

F1

ø 2.79

36

81

64

50.6

6

50

8.8

8.8

68

ø 71

36

0.35

2

2

1

1

1. Position for 1 switched 4

th

pole (1 per device max.) or 1 auxiliary contact.

2. Position for 1 auxiliary contact only.

Note: Maximum of 4 auxiliary contacts, or 3 auxiliary contacts + one switched 4

th

pole.

and …

S

HROUDS

S

W

. 4

TH

P

OLE

6-P

OLE

K

IT

and …

and …

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 508 Non-Fused Rotary Disconnect Switches—16, 25, 40, 63
and 80A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

416

External Selector Handles

13.5

Ø 22.5

3

40

4 Ø 7

Ø 31

28

With Mounting Nut

With 4 Mounting Screws

H4X-01_

Door Drilling Layouts

Handle Type

0

I

90

°

Direction of Front Operation

0

I

90

°

Direction of Right Side Operation

1.57

4 Ø 0.27

1.10

Ø 1.22

0.11

0.53

Ø 0.88

Ø3.07 

1.42

2.79

Ø78 

36

71

Ø78 

37

88

Ø3.07 

1.45

3.46

H4X-02_

1. Position for 1 switched 4

th

pole (1 per device max.) or 1 auxiliary contact.

2. Position for 1 auxiliary contact only.

Note: Maximum of 4 auxiliary contacts, or 3 auxiliary contacts + one switched 4

th

pole.

External Front Operation for 6/8-Pole Disconnects

1.77

3.07

1.36

1.69

0.24

3.50

X

N G

2.67

T T

0.29

2.06

M

F2

2.06

F

J

F1

F1

0.35

2

1

2

1

89

78

43

34.7

6

45

52.5

68

8.8

52.5

8.8

7.5

0.35

1.42

E

ø 

2.79

X

N G

2.67

T T

0.29

2.06

M

F2

2.06

F

J

F1

F1

0.35

2

1

2

1

36

ø 

71

52.5

68

8.8

52.5

8.8

7.5

0.35

Overall

Switch

Switch

Switch

Dimensions

Body

Mounting

Connection

Rating (A)

E min

E max

F

F1

F2

G

J

M

N

T

X

16 to 40

4.13 (105)

14.64 (372) 3.83 (97.5) 0.59 (15)

1.77 (45)

2.67 (68) 1.92 (48.75) 1.18 (30)

2.95 (75) 0.59 (15)

0.29 (7.5)

63 to 80

4.13 (105)

14.65 (372) 4.13 (105)

0.69 (17.5) 2.06 (52.5) 2.99 (76) 2.06 (52.5)

1.38 (3.5)

3.35 (85) 0.69 (17.5) 0.34 (8.75)

Dimensions – in (mm)

Direct Front Operation for 6/8-Pole Disconnects

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 & UL 508 Enclosed Disconnect Switches

Visit us on the web at 

www.cooperbussmann.com/Disconnects

417

Disconnect

Switches

Description

Fused and non-fused enclosed Rotary Disconnect Switches

from 16 to 1200A in NEMA 1, 3R, 4, 4X, 12 enclosures.

Features

• UL 98 Listed for general purpose, main disconnect, or

branch circuit protection up to 600Vac/dc

• UL 508 Listed for motor disconnect applications up to

600Vac

• Multiple field installed accessories enhance the enclosed

disconnect switches to fit the desired application

• Lockout/tagout: Up to three 

1

4

˝ shank padlocks can be

installed on external handles

Ratings:

• Volts: 600Vac

250-600Vdc*

• Amps: 16-1200A

• Short-Circuit Current Ratings: UL 98: 25kA-200kA

UL 508: 10kA-65kA

*Some non-fused disconnect switches are not rated for DC applications.

Specifications

• Operating temperature: -20ºC to 70ºC

• 4X Plastic Enclosure Flammability Rating:

Polycarbonate UL 94-5VA-0

Fiberglass UL 94-5V

Agency Information

• UL 98 Listed: File E182262, Guide WIAX, WIAX7

• UL 508 Listed: File E155129, Guide NLRV, NLRV7

• cULus Listed to CSA Standard 22.2, No. 14

• cULus Listed to CSA Standard 22.2, No. 4

• Conforms with IEC 60947-3

• CE Compliant

• RoHS Compliant

Field Installed Accessories

• Auxiliary contacts

• Terminal shrouds

Online Resources

Visit 

www.cooperbussmann.com/Disconnects

for:

• CAD Drawings

• Instruction Sheets

• UL Information

NEMA 1, 3R, 4 & 12

NEMA 4X 

Polycarbonate 

or Fiberglass

NEMA 4X 

Stainless Steel

Available Bussmann Fuses

Class Type

Data Sheet #

CC

LP-CC Time-Delay, Current Limiting

1023

CC

FNQ-R Time-Delay

1014

CC

KTK-R Fast-Acting

1015

J

LPJ Time-Delay, Current Limiting

1006 (0-60A)

J

1007 (70-600A)

J

With 

easy

ID™open fuse indication

1062 (6-60A)

J

1063 (70-600A)

J

JKS Fast-Acting Fuses

1026 (0-60A)

J

1027 (70-600A)

J

DFJ High Speed Drive Fuse

1048 (0-600A)

L

KRP-C Time-Delay, Current Limiting

1008

L

KTU Fast-Acting 

1010

L

KLU Time-Delay 

1013

QuikShip Everyday Service ships the most common part 

numbers within 24 hours. Contact your Bussmann 

representative for details.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Enclosed Fused Disconnects—30 to 800A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

418

UL General

NEMA Enclosure Type & Part Number

Purpose

Fuse

Amp Rating

Type

1

3R

4

4X Plastic

(1)

4X Stainless

12

30

J

ER1-30J3PB

ER3R-30J3PB

ER4-30J3PB

ER4P-30J3PB

ER4X-30J3PB

ER12-30J3PB

60

J

ER1-60J3PB

ER3R-60J3PB

ER4-60J3PB

ER4P-60J3PB

ER4X-60J3PB

ER12-60J3PB

100

J

ER1-100J3PB

ER3R-100J3PB

ER4-100J3PB

ER4P-100J3PB

ER4X-100J3PB

ER12-100J3PB

200

J

ER1-200J3PB

ER3R-200J3PB

ER4-200J3PB

ER4P-200J3PB

ER4X-200J3PB

ER12-200J3PB

400

J

ER1-400J3PB

ER3R-400J3PB

ER4-400J3PB

ER4P-400J3PB

ER4X-400J3PB

ER12-400J3PB

600

J

ER1-600J3PB

ER3R-600J3PB

ER4-600J3PB

ER4P-600J3PB

ER4X-600J3PB

ER12-600J3PB

800

L

ER1-800L3PB

ER3R-800L3PB

ER4-800L3PB

ER4P-800L3PB

ER4X-800L3PB

ER12-800L3PB

(1) Enclosures ≤100A are polycarbonate, flammability rating UL 94-5VA-V0, ≥200A are fiberglass, flammability rating UL 94-5V.

Switch

Disconnect

Fuse

No. of

Voltage

SCCR

Max Hp Rating

Amp Rating

Switch

Type

Poles

Vac

Vdc

@ Vac

@ 600Vac

30

RDF30J-3

J

20

60

RDF60J-3

J

250

50

100

RDF100J-3

J

600

200kA

75

200

RDF200J-3

J

3

150

400

RDF400J-3

J

350

600

RDF600J-3

J

600

500

800

RDF800L-3

L

Switch Ratings

- for wire types, ranges and tightening torques, see table on page 387

3-Pole UL 98 600Vac

Part Number System:

ER

4X - 60

J

3

P

B

ER

E

nclosed 

R

otary Disconnect

NEMA Rating

1, 3R, 4, 4X (SST), 4P (4X Plastic), 12

Amp Rating

30, 60, 100, 200, 400, 600, 800

Fuse Class

J = Class J, L = Class L

Number of Poles

3 = 3-Pole

Handle Type

P = Pistol

Handle Color

B = Black, R = Red

NEMA 1, 3R, 4 & 12

NEMA 4X Plastic

NEMA 4X Stainless

Part Numbers

-  All part numbers provided with integral or installed lugs and a black selector handle.

Order red/yellow handle by changing the suffix “B” to “R.”

30-800A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Enclosed Fused Disconnects—30 to 800A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

419

Disconnect

Switches

Part

Amp

Fuse

NEMA

Mounting Centers H x W

Weight

Number Family

Rating

Type

Enclosure Type

H x W x D

A

B

C

Lbs

1, 3R, 4, 12

10x10x6

8.3x8.3

15

ER_-30J

30

J

4X-SST

10x10x6

9.5x8.3

8.3x9.5

15

4X-Plastic

(1)

12x10x6

12x5.6

7.64x10

8

1, 3R, 4, 12

12x10x6

10.3x8.3

19

ER_-60J

60

J

4X-SST

12x10x6

11.5x8.3

10.3x9.5

19

4X-Plastic

(1)

13x13x6

14x7.6

9.6x12

11

1, 3R, 4, 12

14x12x6

12.3x10.3

21

ER_-100J

100

J

4X-SST

14x12x6

13.5x10.3

12.3x11.5

21

4X-Plastic

(1)

13x13x6

14x7.6

9.6x12

12

1, 3R, 4, 12

24x20x8

22x18.1

55

ER_-200J

200

J

4X-SST

24x20x8

23.2x18.1

22x19.3

55

4X-Plastic

(1)

27x21x10

25.75x14

39

1, 3R, 4, 12

48x36x12

45.75x34.9

188

ER_-400J

400

J

4X-SST

48x36x12

46.9x34.9

45.75x36.1

188

4X-Plastic

(1)

51x37x14

50.1x28.5

186

1, 3R, 4, 12

48x36x12

45.75x34.9

216

ER_-600J

600

J

4X-SST

48x36x12

46.9x34.9

45.75x36.1

216

4X-Plastic

(1)

51x37x14

50.1x28.5

214

1, 3R, 4, 12

48x36x12

45.75x34.9

216

ER_-800L

800

L

4X-SST

48x36x12

46.9x34.9

45.75x36.1

216

4X-Plastic

(1)

51x37x14

50.1x28.5

214

(1) Enclosures ≤100A are polycarbonate, flammability rating UL 94-5VA-V0, ≥200A are fiberglass, flammability rating UL 94-5V.

Enclosure Weights - Lbs & Dimensions - in

Available Field-Installed Accessories - 

Order Separately

Auxiliary Contacts  - for 30 to 800 Amp Switches

Contact

Number of 

Continuous

Voltage

Max Number of Aux 

Part

Type

Contacts

Amp Rating

Rating

Contacts per Switch

Number

NO

1

10A

600Vac

30 to 200A: 4

BAC05

NC

1

10A

600Vac

400 to 800A: 8

BAC06

Terminal Shrouds - for 200 to 800 Amp Switches

- includes terminal shroud for lineside or loadside

Switch

Number

Part

Amp Rating

of Poles

Number

200

3

TSH8-3TB

400

3

TSH9-3TB

600-800

3

TSH10-3TB

W

W

W

MW

MW

MW

H

H

H

MH

MH

MH

A

B

C

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Enclosed Non-Fused Disconnects—30 to 1200A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

420

Switch

Disconnect

No. of

Voltage

SCCR

Max Hp Rating

Amp Rating

Switch

Poles

Vac

Vdc

@ Vac

@ 600Vac

30

RD30-3

100kA

25

60

RD60-3

N/A

50

100

RD100-3

25kA/100kA*

200

RD200-3

200

400

RD400-3

3

600

250

200kA

350

600

RD600-3

800

RD800-3

N/A

100kA

500

1200

RD1200-3

* 25kA @ 600Vac, 100kA @ 480Vac.

Switch Ratings

- for wire types, ranges and tightening torques, see table on page 405

Part Numbers

-  All part numbers provided with integral or installed lugs and a black selector handle. 

Order red/yellow handle by changing the suffix “B” to “R.”

3-Pole UL 98 600Vac

UL General

NEMA Enclosure Type & Part Number

Purpose

Amp Rating

1

3R

4

4X Plastic

(1)

4X Stainless

12

30

ER1-30N3SB

ER3R-30N3SB

ER4-30N3SB

ER4P-30N3SB

ER4X-30N3SB

ER12-30N3SB

60

ER1-60N3SB

ER3R-60N3SB

ER4-60N3SB

ER4P-60N3SB

ER4X-60N3SB

ER12-60N3SB

100

ER1-100N3SB

ER3R-100N3SB

ER4-100N3SB

ER4P-100N3SB

ER4X-100N3SB

ER12-100N3SB

200

ER1-200N3PB

ER3R-200N3PB

ER4-200N3PB

ER4P-200N3PB

ER4X-200N3PB

ER12-200N3PB

400

ER1-400N3PB

ER3R-400N3PB

ER4-400N3PB

ER4P-400N3PB

ER4X-400N3PB

ER12-400N3PB

600

ER1-600N3PB

ER3R-600N3PB

ER4-600N3PB

ER4P-600N3PB

ER4X-600N3PB

ER12-600N3PB

800

ER1-800N3PB

ER3R-800N3PB

ER4-800N3PB

ER4P-800N3PB

ER4X-800N3PB

ER12-800N3PB

1200

ER1-1200N3PB

ER3R-1200N3PB

ER4-1200N3PB

N/A

ER4X-1200N3PB

ER12-1200N3PB

(1) Enclosures ≤100A are polycarbonate, flammability rating UL 94-5VA-V0, ≥200A are fiberglass, flammability rating UL 94-5V.

NEMA 1, 3R, 4 & 12

30-100A

NEMA 4X

200-1200A

NEMA 1, 3R, 4 & 12

NEMA 4X

NEMA 4X Stainless

NEMA 4X Stainless

Part Number System:

ER

4X - 60

N

3

S

B

ER

E

nclosed 

R

otary Disconnect

NEMA Rating

1, 3R, 4, 4X (SST), 4P (4X Plastic), 12

Amp Rating

30, 60, 100, 200, 400, 600, 800, 1200

N = Non-Fused
Number of Poles

3 = 3-Pole

Handle Type*

P = Pistol, S = Selector

Handle Color

B = Black, R = Red

* ≤100A = Selector only, ≥200A = Pistol only.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 98 Enclosed Non-Fused Disconnects—30 to 1200A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

421

Disconnect

Switches

Part

Amp

NEMA

Mounting Centers H x W

Weight

Number Family

Rating

Enclosure Type

H x W x D

A

B

C

Lbs

1, 3R, 4, 12

10x8x6

8.3x6.3

11

ER_-30

30

4X-SST

10x8x6

9.5x6.3

8.3x7.5

11

4X-Plastic

(1)

9x9x6

10x3.6

5.6x8

5

1, 3R, 4, 12

10x8x6

8.3x6.3

12

ER_-60

60

4X-SST

10x8x6

9.5x6.3

8.3x7.5

12

4X-Plastic

(1)

9x9x6

10x3.6

5.6x8

5

1, 3R, 4, 12

12x10x6

10.3x8.3

12

ER_-100

100

4X-SST

12x10x6

11.5x8.3

0.3x9.5

12

4X-Plastic

(1)

13x13x6

14x7.6

9.6x12

8

1, 3R, 4, 12

20x16x8

18.1x14.2

39

ER_-200

200

4X-SST

20x16x8

19.3x14.2

18.1x15.4

39

4X-Plastic

(1)

23x17x12

21.5x10.1

31

1, 3R, 4, 12

36x30x8

33.9x28.3

122

ER_-400

400

4X-SST

36x30x8

35.1x28.3

33.9x29.5

122

4X-Plastic

(1)

40x32x14

38.1x23.9

103

1, 3R, 4, 12

48x36x12

45.8x34.9

209

ER_-600

600

4X-SST

48x36x12

47x34.9

45.8x36.1

209

4X-Plastic

(1)

51x37x 14

50.1x28.5

187

1, 3R, 4, 12

48x36x12

45.8x34.9

211

ER_-800

800

4X-SST

48x36x12

47x34.9

45.8x36.1

211

4X-Plastic

(1)

51x37x 14

50.1x28.5

189

ER_-1200

1200

1, 3R, 4, 12

60x36x16

57.5x33.9

268

4X-SST

60x36x16

58.7x33.9

57.5x35.1

268

(1)

Enclosures ≤100A are polycarbonate, flammability rating UL 94-5VA-V0, ≥200A are fiberglass, flammability rating UL 94-5V.

Enclosure Weights - Lbs & Dimensions - in

Available Field-Installed Accessories - 

Order Separately

Auxiliary Contacts  - for 30 to 1200 Amp Switches

Switch

Contact

Number of 

Continuous

Voltage

Max Number of Aux 

Part

Amp Rating

Type

Contacts

Amp Rating

Rating

Contacts per Switch

Number

30-100

NO + NC

1 of each

10A

240Vac

4

BAC01

30-100

NC

2

10A

240Vac

4

BAC02

100-1200

NO + NC

1 of each

10.1A

125-250Vac

2

BAC03*

100-1200

NO + NC

1 of each

10.1A

125-250Vac

2

BAC04*

100-1200

NO + NC

1 of each

1A

125Vac

2

BAC11*

100-1200

NO + NC

1 of each

1A

125Vac

2

BAC12*

* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.

Terminal Shrouds - for 200 to 800 Amp Switches

Switch

Number

Location

Part

Amp Rating

of Poles

on Switch

Number

30-100

3

Lineside and Loadside

TSH3-3TB

200A

3

Lineside

TSH4-3T

200A

3

Loadside

TSH4-3B

400A

3

Lineside

TSH5-3T

400A

3

Loadside

TSH5-3B

600A

3

Lineside or Loadside

TSH6-3TB

800-1200A

3

Lineside or Loadside

TSH7-3TB

W

W

W

MW

MW

MW

H

H

H

MH

MH

MH

A

B

C

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 508 Enclosed Non-Fused Disconnects—16 to 80A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

422

3-/6-Pole UL 508 600Vac

Switch

SCCR with 

Max Hp

Amp

Disconnect

Voltage

Max Upstream

Rating

Rating

Switch

Vac

Vdc

Class J Fuse

@ 600Vac

16

RD16-3-508

65kA / 30A

10

25

RD25-3-508

65kA / 30A

20

40

RD40-3-508

600

N/A

65kA / 30A — 10kA / 60A

25

63

RD63-3-508

65kA / 60A — 50kA / 100A

40

80

RD80-3-508

65kA / 60A — 50kA / 100A

40

Note: Voltage, SCCR and Horsepower ratings are the same for 3- and 6-pole UL 508 non-fused disconnect switches.

Switch Ratings

- for wire types, ranges and tightening torques, see table on page 413

UL General 

NEMA Enclosure Type & Part Number

Purpose

No. of

Amp Rating

Poles

1

3R

4

4X Plastic

(1)

4X Stainless

12

16

3

ER1-16N3SB

ER3R-16N3SB

ER4-16N3SB

ER4P-16N3SB

ER4X-16N3SB

ER12-16N3SB

6

ER1-16N6SB

ER3R-16N6SB

ER4-16N6SB

ER4P-16N6SB

ER4X-16N6SB

ER12-16N6SB

25

3

ER1-25N3SB

ER3R-25N3SB

ER4-25N3SB

ER4P-25N3SB

ER4X-25N3SB

ER12-25N3SB

6

ER1-25N6SB

ER3R-25N6SB

ER4-25N6SB

ER4P-25N6SB

ER4X-25N6SB

ER12-25N6SB

40

3

ER1-40N3SB

ER3R-40N3SB

ER4-40N3SB

ER4P-40N3SB

ER4X-40N3SB

ER12-40N3SB

6

ER1-40N6SB

ER3R-40N6SB

ER4-40N6SB

ER4P-40N6SB

ER4X-40N6SB

ER12-40N6SB

63

3

ER1-63N3SB

ER3R-63N3SB

ER4-63N3SB

ER4P-63N3SB

ER4X-63N3SB

ER12-63N3SB

6

ER1-63N6SB

ER3R-63N6SB

ER4-63N6SB

ER4P-63N6SB

ER4X-63N6SB

ER12-63N6SB

80

3

ER1-80N3SB

ER3R-80N3SB

ER4-80N3SB

ER4P-80N3SB

ER4X-80N3SB

ER12-80N3SB

6

ER1-80N6SB

ER3R-80N6SB

ER4-80N6SB

ER4P-80N6SB

ER4X-80N6SB

ER12-80N6SB

(1) Polycarbonate enclosure flammability rating UL 94-5VA-V0.

NEMA 1, 3R, 4 & 12

NEMA 4X Plastic

NEMA 4X Stainless

Part Number System:

ER

4X - 63

N

6

S

B

ER

E

nclosed 

R

otary Disconnect

NEMA Rating

1, 3R, 4, 4X (SST), 4P (4X Plastic), 12

Amp Rating

16, 25, 40, 63, 80

N = Non-Fused
Number of Poles

3 = 3-Pole, 6 = 6-Pole

Handle Type

S = Selector

Handle Color

B = Black, R = Red

Part Numbers

-  All part numbers provided with a black selector handle. Order red/yellow handle by changing the suffix “B” to “R.”

16-80A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

UL 508 Enclosed Non-Fused Disconnects—16 to 80A

Visit us on the web at 

www.cooperbussmann.com/Disconnects

423

Disconnect

Switches

NEMA

No. of

Switch Amp

Mounting Centers H x W

Weight

Enclosure Type

Poles

Ratings

H x W x D

A

B

C

Lbs

1, 3R, 4, 12

3

16-80A

8x6x6

6.3x4.3

8

6

16-80A

10x8x6

8.3x6.3

11

4X-SST

3

16-80A

8x6x6

7.5x4.3

6.3x5.5

8

6

16-80A

10x8x6

9.5x6.3

8.3x7.5

11

3

16-63A

7.4x8.7x5.8

8x3.6

3.6x8

4

4X-Plastic

(1)

80A

9.4x8.7x5.9

10x3.6

5.6x8

5

6

16-80A

11.4x10.7x6.3

12x5.6

7.64x10

6

(1) Polycarbonate.

Enclosure Weights - Lbs & Dimensions - in

Auxillary Contacts

Contact

Number of 

Continuous

Voltage

Max Number of Aux

Part

Type

Contacts

Amp Rating

Rating

Contacts per Switch

Number

NO + NC

1 Ea

10A

240Vac

4

BAC01

NO

2

10A

240Vac

4

BAC02

Auxiliary Contact Configurations

Terminal Shrouds

- includes terminal shroud for both lineside 

and

loadside

Switch

Number

Location on

Part

Amp Rating

of Poles

Switch

Number

16-40A

3

Lineside and Loadside

TSH1-3TB

63-80A

3

Lineside and Loadside

TSH2-3TB

Available Field-Installed Accessories - 

Order Separately

W

W

W

MW

MW

MW

H

H

H

MH

MH

MH

A

B

C

Switched 4

th

Pole

- converts 3-pole switch to 4-pole switch

Switch Amp

Part

Rating

Number

16

POLE-16

25

POLE-25

40

POLE-40

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Disconnect Switches

Visit us on the web at 

www.cooperbussmann.com/Disconnects

424

15149 Series

Specifications

Description:

Fused, dead front disconnect switches

Ratings:

   Volts:  — 600Vac

  Amps:  — 0-30A

SCCR:  — 200kA RMS Sym.

Dielectric SCCR:

2200V

Motor Rating:

5Hp

Poles:

2 to 3

Agency Information:

UL Recognized, file E120756 for

General Industrial  installations. Guide WGEU2. CSA 
certified, file LR37129-6. Examined under the new proposed
standard UL 1429 which imparts a stricter set of test 
conditions than the former program that combined the 
applicable portions for UL 512 (Fuse Holders) and UL 98
(Enclosed Switches).

Features and Benefits

•  Fuse holders in the pull-out head eliminate possibility of

electric shock while changing fuse.

•  Accepts Class J fuses

Ordering Information

To order, specify: 15149 + number of poles.
Example: 15149-2 = 2-pole device.

Flexibility and Convenience Make 
Point-of-Use Configuration Easy

Full range of open disconnect switches with
versatile options and accessories that ship
within 24 hours

www.cooperbussmann.com

Fused, Dead Front Disconnect Switches

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

425

T

elecom

Protection Products

Section Contents                           Page

Telpower compact fused disconnect switches  . . . . .426

Telpower miniature fused disconnect switches  . . . . 427

Fused disconnect switches for TPA fuses

TP15914 4-Pole disconnect switch  . . . . . . . . . . . . . . . .428

TP11590-4 4-Pole disconnect switch    . . . . . . . . . . . . .429

TPA & TPA-B Fuses   . . . . . . . . . . . . . . . . . . . . . . . . . . .429

Fused disconnect switches for TPS fuses

15800 1-Pole fused disconnect switch  . . . . . . . . . . . . 430

TPS Fuses  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .430

Fused disconnect switches

TP158HC panel mount, rear access switch  . . . . . . . . .431

15100 1-Pole switch for use with TPL fuses  . . . . . . . . .432

TPHCS Telpower high-current switch  . . . . . . . . . . . .433

TPL Telpower 70-600A: 170Vdc fuses . . . . . . . . . . . .434

TPN Telpower 1-600A: 170Vdc fuses  . . . . . . . . . . . .435

70 Series Indicating fuses   . . . . . . . . . . . . . . . . . . . . .436

15087 Fuse holders . . . . . . . . . . . . . . . . . . . . . . . . . . .436

HLS, HLT & PCT fuse holders  . . . . . . . . . . . . . . . . . .437

GMT Fast acting fuses  . . . . . . . . . . . . . . . . . . . . . . . .437

GMT-A Fast acting fuse . . . . . . . . . . . . . . . . . . . . . . . .437

Telpower specialty fuses

7 Type Fuses   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438

11 Type Fuse  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438

24 & WER Type non-indicating, visible link fuses  . . . . 438

74 Type Fast acting fuses  . . . . . . . . . . . . . . . . . . . . . . .438

75 Type Cylindrical fuses with leads  . . . . . . . . . . . . . . .439

76 Type Cylindrical fuses with leads  . . . . . . . . . . . . . . .439

80 Type visual indicating fuses  . . . . . . . . . . . . . . . . . . .439

Telecom Protection 
Products

TM

Scan this tag to get the

latest product information for 

Telecom Protection Products.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

426

Telecom Protection Products

Telepower Compact Fused Disconnect Switches

Data Sheet: 5023

TPC & TPCDS

Specifications
Descriptions:

— 

TPC:

Telepower

compact current-
limiting fuses.

— 

TPCDS:

Telepower compact
fused disconnect
switch available in
two disconnect switch profiles in addition to a variety of 
terminal styles. Recommended 0.75” center-to-center 
product spacing.

Dimensions:

See Data Sheet 5023.

Ratings:

Volts: — 80Vdc

Amps: — 3-125A (See Catalog Numbers table for details)

IR: — 100kA

Agency Information:

CE, UL Recognized (investigated to

UL 1801) as a disconnect switch for the interruption of load
current by means of withdrawing the fuse pullout.
Recognized to US and Canadian requirements under the
component recognition program of Underwriters Laboratories
Inc. Files E219046 and E56412.

Flammability Ratings:

Fuse UL 94V0, 170°C RTI,

Housing UL 94V0, 120°C RTI.

Features and Benefits

• Highest interrupting rating (100kA) available and 

complete system coordination for DC circuit protection for  
compact footprint providing a superior protection solution
for replacement of existing DC telecom circuit breakers

• AmpColor ID™ System makes fuse replacement easy
• Local and remote open fuse indication. Local alarm 

indication provided by LED on TPC fuse

• Remote alarm terminal available in three positions 

common to DC circuit protection devices

Typical Applications

• Telecommunications DC power circuit protection
•  Replacement of DC telecom circuit breakers
•  Applications where venting of arc or molten metals and

gases during opening would pose a problem to surrounding
devices

Catalog Numbers

TPCS disconnect switch

TPC Current-Limiting Fuse

Catalog

Amp

Catalog

Amp

Numbers

Range

Numbers

Rating

TPCDS-BBE-1

3-125

TPC-3

3

TPCDS-BBE-2

3-125

TPC-4

4

TPCDS-BBE-3

3-125

TPC-5

5

TPCDS-BBM-1

3-125

TPC-6

6

TPCDS-BBM-2

3-125

TPC-7

7

TPCDS-BBM-3

3-125

TPC-8

8

TPCDS-BSE-1

3-125

TPC-10

10

TPCDS-BSE-2

3-125

TPC-12

12

TPCDS-BSE-3

3-125

TPC-15

15

TPCDS-BSM-1

3-125

TPC-20

20

TPCDS-BSM-2

3-125

TPC-25

25

TPCDS-BSM-3

3-125

TPC-30

30

TPCDS-SSE-1

3-125

TPC-40

40

TPCDS-SSE-2

3-125

TPC-50

50

TPCDS-SSE-3

3-125

TPC-60

60

TPCDS-SSM-1

3-125

TPC-75

75

TPCDS-SSM-2

3-125

TPC-90

90

TPCDS-SSM-3

3-125

TPC-100

100

TPCDS-D-BC1*

3-125

TPC-125

125

TPCDS-D-BC2*

3-125

TPCDS-D-CC1*

3-125

TPCDS-D-SEC1*

3-125

TPCDS-D-SEC2*

3-125

TPCDS-D-SMC1*

3-125

TPCDS-D-SMC2*

3-125

*Not investigated to Canadian Requirements.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

427

Data Sheet: 5022

Telepower Miniature Fused Disconnect Switches

Catalog Numbers

Catalog

Amp

Numbers

Description

Rating

TPM-3

Fuse

3

TPM-4

Fuse

4

TPM-5

Fuse

5

TPM-6

Fuse

6

TPM-7

Fuse

7

TPM-8

Fuse

8

TPM-10

Fuse

10

TPM-12

Fuse

12

TPM-15

Fuse

15

TPM-20

Fuse

20

TPM-25

Fuse

25

TPM-30

Fuse

30

TPMDS-E

Disconnect, English hardware

3-30

TPMDS-M

Disconnect, Metric hardware

3-30

NOTES:

1. The resistance, R, must be provided by the end-user to
limit the alarm output current to a maximum of 20mA. The
value, R, should be calculated using the system voltage
value.

• If remote alarm functionality is not required, the 

END-USER CIRCUITRY must still be supplied to provide a 
resistive path to the return for the local alarm to properly
function.

2. The fuse is polarized to maintain proper orientation with
the switch housing. The line and load terminals are
identified on the switch housing.

TPM &
TPMDS

Specifications
Description:

— TPM:

Telepower 
miniature current-
limiting fuses.

— TPMDS:

Telepower 
miniature fused
disconnect switch.

Dimensions:

See Data Sheet 5022.

Ratings:

Volts: — 80Vdc

Amps: — 3-30A

IR: — 20kA

Agency Information:

CE, UL Recognized (investigated to

UL 1801) as a disconnect switch for the interruption of load
current by means of withdrawing the fuse pullout.
Recognized to US and Canadian requirements under the
component recognition program of Underwriters Laboratories
Inc. Files E219046 and E56412.

Flammability Ratings:

Fuse UL 94V0, 170ºC RTI; Switch

UL 94V0, 140ºC RTI.

Features and Benefits

• Smallest and most versatile fused disconnect switch 

available allowing for assembly into 1 U (1.75˝/44.5mm)
panel. Easy to connect; Load: 

1

4

˝ quick-connect or bolted  

connection with 10-32 (M5) captive nut, Line: 

1

4

˝ 

quick-connect or screw connection with clearance hole for 
#10 (M5) bolt.

• AmpColor ID™ System makes fuse replacement easy
• Switch design provides for easy panel mounting by single

captive 4-40 (M3) nut and panel notch integral to switch 
footprint.

• Complete system coordination capability with local and 

remote open fuse indication. Local alarm indication 
provided by LED on TPM fuse (maximum alarm circuit 
current: 20mA)

Typical Applications

• Telecommunications DC power circuit protection
• Applications with restricted space, or mounting in 1 U panels

TPM Alarm Schematic

Telecom Protection Products

T

elecom

Protection Products

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

428

Telecom Protection Products

TP15914

Specifications
Description:

Modular 4-pole 
disconnect switch
for TPA Series
fuses — 4-poles
per module up to
four modules
ganged together.
Features open fuse
indication and fuse presence indication along with fuse 
orientation rejection feature.

Dimensions:

See Dimensions illustrations.

Ratings:

Volts: — 145Vdc

Amps: — 50A per pole

Agency Information:

CE, UL Recognized as a disconnect

switch for interruption of load current by means of 
withdrawing the fuse carrier. UL Recognized as a component
for telecommunication power distribution equipment (UL 
category QPQYZ), UL Recognized fuses for branch circuit
protection, CSA component acceptance for the system. UL
Recognized, Guide JFHR2, File E56412., CSA Certified,
Class 1422-30, File 53787.

Flammability Rating:

UL 94V0, 140°C.

Features and Benefits

• Totally enclosed module directly connects to busbar for 

reduced external wiring—per pole and easy installation 
with front access load and line connection standard—
double lug load connections 8 AWG wire

• LED alarm signaling (LED current 30mA max)
• Remote alarm with alarm test probe point to allow on-site 

checking of alarm circuitry

• Bi-polar LED provides capability for both –48Vdc and

+24Vdc applications

Typical Applications

• Telecommunications DC power circuit protection

Catalog Numbers

Catalog
Numbers

Hardware

TP15914

English

TP15914-1

Metric

Fused Disconnect Switches for TPA Fuses

Data Sheet: 5011

Dimensions mm - (in)

Accessories

•  Spare fuse holders: Catalog Numbers 5TPH and TPSFH-A

0.745

0.284

1.5

4.27

3.57

0.625

0.215

1.5

TOP

76.07

3.0

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

429

TP15900-4

Specifications
Description:

4-pole

disconnect switch for
use with Telepower
fuses Type TPA &
TPA-B.

Dimensions:

See Dimensions illustrations.

Ratings:

Volts: — 145Vdc (40A)

— 80Vdc (50A)

Amps: — 40A@145Vdc 

— 50A@80Vdc 

Agency Information:

CE, UL Recognized File E97649 as

a disconnect switch for interruption of  load current by means
of withdrawing the fuse carrier. UL Recognized as a 
component for telecommunication  power distribution 
equipment (UL category QPQY2). UL Recognized fuses for
branch circuit protection. CSA Component Acceptance for
the system.

Flammability Rating: 

UL 94V0, 140°C.

Features and Benefits

•  Ease of installation - connection directly to busbar, 

reduces external wiring per pole. Rear accessibility for line 
and load terminations

•  LED alarm signaling (LED current 30mA max)
•  Local and remote open-fuse indication along with fuse 

orientation rejection feature and fuse presence indication

•  Alarm test probe point, to allow on-site checking of alarm 

circuitry

Typical Applications

• Telecommunications DC power circuit protection

Catalog Numbers

Catalog
Numbers

Description

TP15900-4

4-Pole common disconnect switch

TP15900-41

4-Pole common disconnect switch w/ 

Split Alarm, Split Line

Dimensions - mm (in)

Accessories

•  Spare fuse holders: Catalog Numbers 5TPH and

TPSFH-AS.

Fused Disconnect Switches for TPA Fuses

Data Sheet: 5001

-

Data Sheet: 5012

TPA & TPA-B

Specifications
Description:

DC power distribution 

indicating fuses.

Dimensions: 

See Dimensions illustration.

Ratings:

Volts: — 170Vdc TPA

— 65Vdc TPA-B

Amps: — 3-50A TPA

— 20-30A TPA-B

IR: — 100kA TPA

— 20kA TPA-B

Agency Information:

CE, UL Recognized, Guide JFHR2,

File E56412, CSA Certified, Class 1422-30, File 53787.

Features and Benefits

• Indication pin provides for local and remote indication when

used with Bussmann TP15900-4 and TP15914 disconnect  
switches

• Patented “orange ring” fuse orientation features assures 

correct fuse position

• The UL Recognized ratings and current-limiting capability  

make this fuse ideal for cable protection on existing DC 
power distribution systems

•  A unique blue label is used on all Telepower fuses to 

designate their DC capability

Typical Applications

• Telecommunications DC power circuit protection

Catalog Numbers (Amps)

Catalog

Amp

Catalog

Amp

Numbers

Rating

Numbers

Rating

TPA-3

3

TPA-30

30

TPA-5

5

TPA-40

40

TPA-10

10

TPA-50

50

TPA-15

15

TPA-B-20

20

TPA-20

20

TPA-B-25

25

TPA-25

25

TPA-B-30

30

Dimensions - mm (in)

Accessories

• Spare fuse holders: 5 position holder; 5TPH; 6 position 

holder; TPSFH-AS

• Use with fused disconnect switches TP15900-4, TP15914

Telecom Protection Products

T

elecom

Protection Products

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

430

Telecom Protection Products

TPS

Specifications
Description:

DC

power distribution 
non-indicating fuses
specifically designed to
meet the unique needs
of DC power distribution systems. For use with Bussmann
fused disconnect switch 15800.

Dimensions: 

See Dimensions illustration.

Ratings:

Volts: — 170Vdc

Amps: — 1-70A

IR: — 100kA

Agency Information:

CE, UL Recognized, Guide JFHR2,

File E56412.

Features/Benefits

•  The UL Recognized ratings and current-limiting capability

make this fuse ideal for cable protection on existing DC 
power distribution systems

•  A unique blue label is used on all Telepower fuses to 

designate their DC capability

•  Printed circuit board variations available

Typical Applications

• Telecommunications DC power circuit protection
• Applications requiring printed circuit board mounting

Catalog Numbers (Amps)

TPS-1

TPS-6L

TPS-30

TPS-50V

TPS-1L

TPS-10

TPS-30L

TPS-60

TPS-2

TPS-10L

TPS-35

TPS-60L

TPS-2L

TPS-15

TPS-35L

TPS-70

TPS-3

TPS-15L

TPS-40

TPS-70L

TPS-3L

TPS-20

TPS-40L

TPS-70LB

TPS-5

TPS-20L

TPS-40V

TPS-5L

TPS-25

TPS-50

TPS-6

TPS-25L

TPS-50L

Dimensions - in (mm)

Accessories

•  Spare fuse holder: TPSFH-AS, see page 510.

Fused Disconnect Switches for TPS Fuses

Data Sheet: 5009

15800

Specifications
Description:

Fused disconnect
switch for use only
with the following 
fuses; Main: Telepower
TPS 3 to 70 Amp, 
Alarm: Bussmann GMT-A
only (page 399).
Recommend GMT-X Cover 
(page 437).

Dimensions:

See Dimensions illustration.

Ratings:

Volts: — 60Vdc

Amps: — 3-70A

SCCR: — 100kA

Agency Information:

CE, UL Recognized, Guide QPQY2,

File E97649.

Flammability Rating:

UL 94V0, 150°C.

Features and Benefits

•  Alarm output with wire wrap terminal or connection to 0.063”

thick common alarm bus

•  Spare alarm and power fuse compartment
•  Mounting hardware included

Typical Applications:

• Telecommunications DC power circuit protection

Catalog Numbers

Catalog
Numbers

Access Panel Mounting

15800-R-200

Rear

15800-F-200

Front

Dimensions - in (mm)

Accessories

•  Spare fuse holders: Catalog Numbers TPSFH-AS (TPS

fuses) and TPSFH-T (GMT fuses).

Data Sheet: 5002

 

72 lb-in

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

431

TP158HC

Specifications
Description:

Panel mount, rear

access high amp version of
Bussmann 15800 series fused 
disconnect switch for use only with
the following fuses; Main:
Telepower TPL-B 70-250 Amps,
Alarm: Bussmann GMT-A.

Dimensions: 

See Data Sheet

5021.

Ratings:

Volts: — 80Vdc

Amps: — 70-250A

SCCR: — 100kA

Agency Information:

UL Recognized (investigated to UL

1801) as a disconnect switch for the interruption of load 
current by means of withdrawing the fuse pullout. Guide
QPQY2, File E97649.

Flammability Rating:

UL 94V0, 150°C.

Features and Benefits

• Similar profile, mounting method, and backplane 

configuration as 15800 Series. The TP158HC can be  
installed into existing 15800 Series panels using the space 
of two 15800 disconnects

• Innovative new fuse pullout design eliminates need for 

tools to replace the Telepower type TPL-B fuse

• Alarm output with wire wrap terminal or connection to 

0.063 inch (1.6mm) thick common alarm bus

• Hardware included: Load: washer, split lockwasher, and 

5

16

- 18 nut (metric-M8 x 1.25)

Typical Applications:

• Telecommunications DC power circuit protection

Catalog Numbers

Catalog
Numbers

Hardware

TP158HC

English

TP158HC-M

Metric

Accessories

• Spare fuse holders: TPSFH-LB (TPL-B fuses) and TPSFH-T

(GMT fuses).

Application Notes

•  The line connection uses a 

1

4

-20 bolt (metric – M6X1) that

threads into the line terminal. The line terminal is designed
with a float of ±0.02˝ (±0.50mm) to allow for variation in the
distance between the TP158HC mounting flange and the
line busbar (see Dimensions). Equipment should be
designed to eliminate any relative movement between the
TP158HC mounting flange and the line busbar.

• The alarm circuit is not intended for precharging of 

capacitive circuits. Alarm circuit current 1A maximum.

Fused Disconnect Switches

Data Sheet: 5021

Easy Fuse Replacement

Telecom Protection Products

T

elecom

Protection Products

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

432

Telecom Protection Products

Fused Disconnect Switches

0.27" 

(6.75mm)

 

Dia. Hole with 0.5"

 

(12.7mm)

Dia. x 0.16" 

(3.97mm)

 Deep C'bore (4 Holes)

2.63"

(66.67mm)

1.31"

(33.33mm)

4"

(101.6mm)

3"

(76.2mm)

5.25"

(133.35mm)

7.13"

(181.10mm)

3.63"

(92.07mm)

2.75"

(69.85mm)

6

.75

"

(171.45mm)

5.75"

(146.05mm)

15100

Specifications
Description:

Fused 

disconnect system for use with
Telepower fuses Type TPL.

Dimensions:

See Dimensions

illustrations.

Ratings:

Volts: — 60Vdc

Amps: — 70-800A

SCCR: — 100kA

Agency Information:

CE, UL Recognized, Guide QPQY2,

File E97649.

Features and Benefits

• Single-pole fusible disconnect switch for primary DC power 

distribution

• Robust housing and terminal construction for demanding 

applications

• Panel mounting
• Easily connected to line or load bus

Typical Applications

• Telecommunications DC power circuit protection

Catalog Numbers

Catalog

For Use With

Numbers

TPL Series Fuses

15100-401

70-400A

15100-601

300-800A

Dimensions - in (mm)

Data Sheet: 5003

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

433

TPHCS

Specifications
Description:

High

current switch for
use with Telepower
fuses Type TPL-B,
TPL-C and TPH.
Available as 
complete switch or pullout.
Base may be purchased 
separately.

Dimensions:

See Dimensions illustrations.

Construction:

Ratings:

Volts: — 80Vdc

Amps: — 70-800A

SCCR: — 100kA

Agency Information:

UL Recognized (investigated to UL

1801) as a disconnect switch for the interruption of load 
current by means of withdrawing the fuse carrier. UL
Recognized to meet the requirements for Canadian
Standards.

Features and Benefits

•  Innovative design eliminates need for tools to replace the 

Telepower

Type TPL-B, TPL-C or TPH fuse

•  Easy to install–captive fasteners allow for direct busbar 

mounting (bolts not included). Standard 

1

4

” male quick-

connect terminal for effortless remote alarm connection.

•  Optional new electronic alarm eliminates need for parallel 

indicating fuses while providing local and remote open-
fuse indications (maximum remote alarm current: 20mA);  
Bipolar alarm: designed for both Central Office and Radio 
applications, Local LED alarm indication for 
ease-of-viewing.

•  Fuse presence window allows for easy viewing of installed

fuse amp rating

Typical Applications

• Telecommunications DC power circuit protection
• Compact design is ideal for today’s high power, 

high-density cabinets

Telpower High-current Switch

Data Sheet: 5020

Catalog Numbers – Switches (Pullout and Base)

Catalog

Hardware/

Fuse

Amp

Numbers

Option

Series

Rating

TPHCS250-M

Metric

TPL-B

70-250

TPHCS250-E

English

TPL-B

70-250

TPHCS250-ML

Metric, LED

TPL-B

70-250

TPHCS250-EL

English, LED

TPL-B

70-250

TPHCS250-MAV

Metric, Alarm

TPL-B

70-250

TPHCS250-EAV

English, Alarm

TPL-B

70-250

TPHCS800-M

Metric

TPL-C or TPH

300-800

TPHCS800-E

English

TPL-C or TPH

300-800

TPHCS800-ML

Metric, LED

TPL-C or TPH

300-800

TPHCS800-EL

English, LED

TPL-C or TPH

300-800

TPHCS800-MAV

Metric, Alarm

TPL-C or TPH

300-800

TPHCS800-EAV

English, Alarm

TPL-C or TPH

300-800

Catalog Numbers – Components

Catalog

Description

Fuse

Amp

Numbers

Rating/Hardware/Option

Series

Rating

TPHCS250-P

Pullout only – 250A

TPL-B

70-250

TPHCS800-P

Pullout only – 800A

TPL-C or TPH

300-800

TPHCS-B-M

Base only, Metric

800 Max

TPHCS-B-E

Base only, English

800 Max

TPHCS-B-ML

Base only, Metric, LED

800 Max

TPHCS-B-EL

Base only, English, LED

800 Max

TPHCS-B-MAV

Base only, Metric, Alarm

800 Max

TPHCS-B-EAV

Base only, English, Alarm

800 Max

Dimensions - mm (in)

TPHCS800-MAV (shown)

NOTES:

1. TPHCS250 and TPHCS800 pullouts and bases are the same with exception to the type of
fuse, TPL-B, TPL-C or TPH the pullout will carry.
2. Plastic rated UL 94V0, 140ºC RTI.

41.02
(1.615)

Ø 7.62
(0.300)
Type. 4

12.7
(0.50)

74.6
(2.94)

25.9
(1.02)

122.43
(4.820)

8.8
(0.34)

L

L

L

L

L

L

L

L

L

L

L

L

L

L

100.5 

REF

(3.96)

L

L

L

L

L

L

L

66.4
(2.62)

L

L

105.2
(4.14)

L

L

Threaded Insert, 4 Places
M8x1.25 (-M Series) 5/16-18 (-E Series)
Recommended Torque 15N

• 

m (11 Ft-lb)

Tin-Plated 
Copper
Terminals

L

L

L

L

139.7
(5.50)

24.8 

REF

(0.98)

39.2 

REF

(1.54)

16.76
(0.660)

L

L

13.2
(0.52)

17.3
(0.68)

L

L

L

61.47

(2.420)

L

22.2
(0.88)

See table for part
number format

L

L

Telecom Protection Products

T

elecom

Protection Products

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

434

Telecom Protection Products

Telpower 70-600A: 170Vdc Fuses

Data Sheet: 5005

TPL

Specifications
Description:

DC power distribution

fuses for use with Telepower 15100,
15200, TP158HC and TPHCS 
disconnect systems. For replacement of
Bussmann UBO fuses a TPL-TA adapter
kit is necessary.

Dimensions:

See Dimensions 

illustrations.

Ratings:

Volts: — 170Vdc

Amps: — 70-800A

IR: — 100kA

Agency Information:

CE, UL Recognized Guide JFHR2,

File E56412  Bellcore.

Features and Benefits

•  Current-limiting capability designed for DC power 

distribution systems

•  Recognized branch circuit protection
•  Complete system coordination capability
•  Energy savings with low watts loss, low operating 

temperatures, and minimum I

2

t levels

Typical Applications

• Telecommunications power circuit protection

Catalog Numbers

Catalog

Amp

Numbers

Rating

TPL-

B

A

70

TPL-

BB

80

TPL-

B

C

90

TPL-

B

D

100

TPL-

B

E

125

TPL-

B

F

150

TPL-

B

G

175

TPL-

B

H

200

TPL-

B

K

225

TPL-

B

L

250

TPL-CN

300

TPL-CO

350

TPL-CR

400

TPL-CU

450

TPL-CV

500

TPL-CZ

600

TPL-CZH

800

Accessories

•  Spare fuse holders: TPSFH-LB (for TPL-B fuses) 

TPSFH-LC (for TPL-C fuses)

Dimensions - in (mm)

0.33" 

(8.3mm) 

2.66" 

(67.5mm) 

2.19" 

(55.6mm) 

1.91" 

(48.4mm) 

1.16" 

(29.4mm) 

BUSS 

TPL–B L 

0.75" 

(19.1mm) 

0.19" 

(4.8mm) 

1.0" 

(25.4mm) 

0.25" 

(6.4mm) 

1.50" 

(38.1mm) 

TPL-BA, TPL-BD, TPL-BF 

, TPL-BH, TPL-BK, and TPL-BL

TPL-CN, TPL-CR, TPL-CV and TPL-CZ

3.50" 

(88.9mm) 

2.44" 

(61.9mm) 

1.25" 

(31.8mm) 

1.00" 

(25.4mm) 

0.41" 

(10.3mm) 

BUSS 

TPL – CZ 

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

435

Telpower 1-600A, 170Vdc Fuses

Data Sheet: 5006

TPN

Specifications
Description:

Current-

limiting DC power 
distribution fuses. The
TPN fuse series is
dimensionally similar to
Class R fuses making it
easy to use standard
Class R fuse blocks.

Dimensions:

See Dimensions illustrations.

Ratings:

Volts: — 170Vdc

Amps: — 1-600A

IR: — 100kA

Agency Information:

UL Recognized, Guide JFHR2, File

E56412.

Features/Benefits

•  Current-limiting capability designed for DC power 

distribution systems

•  Recognized branch circuit protection
•  Complete system coordination capability
•  Energy savings with low watts loss, low operating 

temperatures, and minimum I

2

t levels

Typical Applications

• Telecommunications power circuit protection

Catalog Numbers (Amps)

TPN-1

TPN-45

TPN-200

TPN-3

TPN-50

TPN-225

TPN-5

TPN-60

TPN-250

TPN-6

TPN-70

TPN-300

TPN-10

TPN-80

TPN-350

TPN-15

TPN-90

TPN-400

TPN-20

TPN-100

TPN-450

TPN-25

TPN-110

TPN-500

TPN-30

TPN-125

TPN-600

TPN-35

TPN-150

TPN-40

TPN-175

Accessories

• Spare fuse holders:TPSFH-N30 (for TPN 1-30) TPSFH-N60

(for TPN 35-60)

Recommended Class R Fuse Blocks

Catalog

Amps

Poles

Number

1-30

1

R25030-1CR

1-30

2

R25030-2CR

1-30

3

R25030-3CR

35-60

1

R25060-1CR

35-60

2

R25060-2CR

35-60

3

R25060-3CR

70-100

1

R25100-1CR

70-100

2

R25100-2CR

70-100

3

R25100-3CR

110-200

1

R25200-1CR

110-200

3

R25200-3CR

225-400

1

R25400-1CR

225-400

3

R25400-3CR

450-600

1

R25600-1CR

450-600

3

R25600-3CR

0.81"

(20.6mm)

3"

(76.2mm)

35A to 60A

2"

(50.8mm)

0.56"

(14.3mm)

1A to 30A

5.88"

(149.2mm)

70A to 100A

7.13"

(181.0mm)

110A to 200A

225A to 400A

8.63"

(219.1mm)

450A to 600A

10.38"

(263.5mm)

2.50"

(63.5mm)

2.00"

(50.8mm)

1.50"

(38.1mm)

1.00"

(25.4mm)

Dimensions - in (mm)

Telecom Protection Products

T

elecom

Protection Products

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

436

Telecom Protection Products

70 Series Fuses

Specifications
Description:

Indicating type fuse.

Ratings:

Volts: — 125Vac/300Vdc

Amps: — 

1

10

-10A

IR: — 1kA @ 300Vdc

Agency Information:

CE, UL Recognized,

Guide JDYX2, File E19180 Bellcore.

Catalog Numbers

Lucent

Catalog

Amp

Color

Comcode

Code/

Numbers

Rating

Code

Ref. No.

List No.

70P-

1

10

A*

1

10

Gray/Wh

100203413

KS23751-L10

70R-

15

100

A*

15

100

Red/Wh

101384550

KS23751-L11

70E-

18

100

A*

18

100

Yellow

100203363

KS23751-L5

70X-

2

10

A

2

10

Black

70F-

1

4

A*

1

4

Violet

100203371

KS23751-L6

70K-

1

4

A*

1

4

Violet/Wh

100203405

KS23751-L9

70G-

1

2

A*

1

2

Red

100203389

KS23751-L7

70H-

3

4

A*

3

4

Brown

100203397

KS23751-L8

70I-1A

1

Pink

70A-1

1

3

A*

1

1

3

White

100203322

KS23751-L1

70B-2A*

2

Orange

100203330

KS23751-L2

70C-3A*

3

Blue

100203348

KS23751-L3

70J-3

1

2

A

3

1

2

Black/Wh

70D-5A*

5

Grn/Blk

100203355

KS23751-L4

70L-6A

6

Grn/Wh

70M-8A

8

Brown/Wh

70N-10A

10

Violet/Yel

GKB-10A

10

Violet/Yel

72A Plastic CaseDummy

100203421

72B Blister PackDummy

103757977

*Product designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1,
December 1988.

No longer UL Recognized.

Indicating Fuses and Holders

Data Sheet: 5007

Data Sheet: 5007

15087 Fuse Holder

Specifications
Description:

Fuse holder

for 70 Series fuses.

Ratings:

Volts: — 300Vdc

Amps: — 12A

Agency Information:

CE, UL

Recognized, Guide IZLT2, File
E14853.

Flammability Rating: 

UL 94V0.

Features and Benefits

•  Panel mount fuse holder for 70 Type fuses supplied with  

two screws

•  Remote alarm capability

Typical Applications

• Telecommunications DC power circuit protection

Catalog Number — 15087

Accessories
Description:

Optional color code eyelets used with fuse

holder to indicate fuse amp rating.

Eyelet Catalog Numbers

Catalog

Amp

Color

Numbers

Indication

Code

1A1706-01

18

100

Yellow

1A1706-02

2

10

Black

1A1706-03

1

4

Violet

1A1706-04

1

4

Violet/White

1A1706-05

1

2

Red

1A1706-06

3

4

Brown

1A1706-07

1

Pink

1A1706-08

1

1

3

White

1A1706-09

2

Orange

1A1706-10

3

Blue

1A1706-11

5

Green/Black

1A1706-12

6

Green/White

1A1706-13

8

Brown/White

1A1706-14

10

Violet/Yellow

1A1706-15

1

10

Gray/White

1A1706-16

3

1

2

Black/White

1A1706-17

15

100

Red/White

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

437

HLS, HLT, PCT

Specifications
Description:

Fuse

holders for GMT Type
indicating fuses.

Poles: 

01 to 25.

Ratings:

Volts: — 

60Vdc/125Vac 

Agency Information:

CE, UL Recognized,
Guide IZLT2, File

E14853, 15A (60Vdc).

Flammability Rating: 

UL 94V0.

Features and Benefits

• Multiple configurations provide

application flexibility

• Compact size saves space

Typical Applications

• Telecommunications DC power circuit protection

Catalog Numbers

Catalog Numbers

Poles

PCT

1

HLS

See Build-A-Code

HLT

See Build-A-Code

Indicating Fuses and Holders

Data Sheet: 5008

Data Sheet: 5010

Multiple  Fuse holders with bus bars
Ordering Information— Catalog No. 

T ype of bus bars used*** 

B1*, B2, B3, 
B4, B5, SL**  

(Short Leads .135") 

               

ML** 

  

(Medium Leads .250") 

                                              **  Not  available  with  bus  bars 

  Bus  Bar  Position 

P4 

(Outside— 
Left Only) 

P3 

(Outside— 
Right Only) 

P2 

(Outside— 
Both  Sides) 

P1† 

(Inside— 

Both  Sides) 

B3 

(“U”  Bar  Only) 

B2 

(“L”  

Bar  Only) 

B1 

(Angle Bar Only)* 

B5 

(“L” & “U” Bars)  

B4 

(Angle & “L” Bars)  

Body Style 

 HL T 

                                  

      HLS  

(No  flanges) 

No. of  Poles  

01 

 thru  

25 

(Min. of 2 poles required for bus bars) 

T ermination Location 

(Both ends) 

(Left only) 

(Right only) 

 *Angle Bar 

mounts on common or center terminals only. 

**SL 

Version is not available with bus bars. 

†Minimum of 4 Poles Required. 

***.38 max. leads if not specified. 

GMT - Dummy

GMT - A (Alarm)

GMT

Specifications
Description:

Fast-acting fuses for use in HLT, HLS, and

PCT fuse holders.

Ratings:

Volts: — 60Vdc/125Vac

Amps: — 

18

100

-15A

IR: — 450A@60Vdc

— 300A@125Vac

Agency Information:

CE, UL Recognized, Guide JFHR2,

File E56412.

Flammability Rating:

UL 94V0.

Features and Benefits

• Local and remote indication capability
• Color coded for easy amp rating identification

Typical Applications

• Telecommunications DC power circuit protection

Catalog Numbers

Catalog

Color

Catalog

Color

Numbers

Code

Numbers

Code

GMT-

18

100

A

Yellow

GMT-3-

1

2

A

White/

B

lue

GMT-

1

4

A

Violet

GMT-4A

White/

B

rown

GMT-

3

8

A

Green/Gray

GMT-5A

Green

GMT-

1

2

A

Red

GMT-7-

1

2

A

B

lack/White

GMT-

65

100

A

B

lack

GMT-10A

Red/White

GMT-

3

4

A

B

rown

GMT-12A

Yellow/Green

GMT-1A

Gray

GMT-15A

Red/

B

lue

GMT-1-

1

3

A

White

GMT-Dummy

Gray 

B

ody

GMT-1-

1

2

A

White/Yellow

GMT-X

Clear Cover

GMT-2A

Orange

GMT-Y

Clear Cover

GMT-3A

B

lue

Some GMT sizes may be sold in bulk pack only.

Accessories

• Spare fuse holder: Catalog Number TPSFH-T

GMT-A

Specifications
Description:

Fast-acting fuse designed specifically for use

in the Telepower series 15800 fused disconnect switch 
(page 430).

Agency Information:

The GMT-A has the same ratings

and agency approvals as the standard GMT fuses as shown
above.

Catalog Numbers

Catalog Number

Color Code

GMT-A

Yellow

Telecom Protection Products

T

elecom

Protection Products

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

438

Telecom Protection Products

11 Type

Specifications
Description:

Fiber tube, threaded ends, identical to 7 Type

except for vent slots in fiber tube.

Dimensions: 

See Dimensions illustration.

Ratings:

Amps: — 7A

Agency Information:

CE

Catalog Number

Catalog

Amp

Lucent Comcode

Number

Rating

Ref. No.

11C-7

7

100863745

Dimensions - in

7 Type

Specifications
Description:

Fiber tube, threaded ends. Typically used on

wall type main distribution frames and central battery 
substations.

Dimensions: 

See Catalog Numbers table and Dimensions

illustration.

Ratings:

Amps: — 7A

Agency Information:

CE

Catalog Numbers

Catalog

Amp

Lucent Comcode Dimension

Numbers

Rating

Ref. No.

A Length (in)

7A-7

7

100863737

4.562

7T-7

7

100202753

4.828

Dimensions - in

24 and WER Type

Specifications
Description:

Flat, non-indicating visible

link element mounted on 1 inch centers
using either No. 6 or No. 10 screws.

Dimensions: 

See Dimensions illustration.

Ratings:

Volts: — 32Vdc (

1

4

, 1, 3 

1

2

, 8, 10A)

— 60Vdc (

1

2

3

4

, 1 

1

2

, 2, 3, 4, 5A)

Amps: — 

1

4

-10A

Agency Information:

CE, UL Recognized File E56412.

Catalog Numbers

Catalog

Amp

DC

Color

Lucent Comcode

A Length

Numbers

Rating

Volts

Code

Ref. No.

Inches

WER-

1

4

1

4

32

24E-

1

2

*

1

2

60

Red

100202894

0.20

24D-

3

4

*

3

4

60

Black

100202886

0.15

WER-1

1

32

24G-1-

1

3

*

1

3

60

White

100202910

0.20

24C-2

*

2

60

Orange

100202878

0.20

24B-3

*

3

60

Blue

100202852

0.15

WER-3-

1

2

1

2

32

24B-4

*

4

60

Yellow

100202860

0.15

24F-5

*

5

60

Green

100202902

0.15

WER-8

8

32

WER-10

10

32

*Designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1, Dec. 1988.

Dimensions - in

Telpower Specialty Fuses

4.062"

4.625"

4.093"

A

A  0.375"

A

0.938"

1.406"

74 Type

Specifications
Description:

Fast-acting 0.281˝ x 1.25˝ cylindrical fuse

designed to comply with Lucent specification KS23753. High
current companion to 70 Type Fuse.

Dimensions: 

See Dimensions illustration.

Ratings:

Volts: — 60Vdc

Amps: — 1 

1

4

-20A

Agency Information:

CE, UL Recognized File E19180.

Catalog Numbers

Catalog

Amp

Lucent Comcode

Code/

Numbers

Rating

Ref. No.

List No.

74A-1-

1

4

1

4

102630290

KS23753-L1

74G-2

2

103064952

KS23753-L7

74B-3

3

102630308

KS23753-L2

74H-4

4

103264669

KS23753-L8

74C-5

5

102630316

KS23753-L3

74J-7-

1

2

1

2

103228425

KS23753-L9

74D-10

10

102630324

KS23753-L4

74E-15

15

102630332

KS23753-L5

74F-20

20

102630340

KS23753-L6

Dimensions - in (mm)

1.25"

(31.75mm)

0.281"

(7.14mm)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

439

80 Type

Specifications
Description:

A fuse designed for high reliability applications

where high ambient temperatures, low circuit voltages, low
power dissipation and low contact resistance are prime 
considerations. The 80 Type is a visual indicating fuse with
remote electrical alarm capability. UL Recognized, Guide
JDYX2, File E19180.

Dimensions:

See Dimensions illustrations.

Ratings:

Volts: — 160Vdc

Amps: — 

1

2

-5A

Agency Information:

CE, UL Recognized File E19180.

Catalog Numbers

Catalog

Amp

Color

Lucent Comcode Code/

Numbers Rating

Code

Ref. No.

List No.

80G-

1

2

1

2

Red

103839916

KS23824-L6

80M-1-

1

3

1

1

3

White

408078657

KS23824-L8

80B-2

2

Orange

103752150

KS23824-L2

80C-3

3

Blue

103752168

KS23824-L3

80D-5

5

Green

103800637

KS23824-L4

Dimensions - in (mm)

75 Type

Specifications
Description:

Cylindrical with leads,

designed to provide protection against
currents resulting from the application of foreign voltages.
Application for data sets and telephones.

Dimensions: 

See Dimensions illustration.

Ratings:

Volts: — 135Vac/220Vdc (440Vdc@0.007A)

Amps: — 0.007-0.230A

Agency Information:

CE

Catalog Numbers

Catalog

Amp

Lucent Comcode

Code/

Numbers

Rating

Ref. No.

List No.

75C

0.007

103260816

KS23825-L3

75F

0.063

104172861

KS23825-L6

75B

0.115

102732112

KS23825-L2

75D

0.129

104013180

KS23825-L4

75A

0.200

102660008

KS23825-L1

76 Type

Specifications
Description:

Cylindrical with leads,

designed to provide protection against
currents resulting from the application
of foreign voltages. Application for data
sets and telephones.

Dimensions: 

See Dimensions illustration.

Ratings:

Volts: — 135Vac/440Vdc

Amps: — 0.012-0.412A

Agency Information:

CE

Catalog Numbers

Catalog

Amp

Lucent Comcode Code/

Numbers

Rating

Ref. No.

List No.

76D

0.012

103798245

KS23825-L10

76B

0.191

102965688

KS23825-L8

76A

0.231

102810181

KS23825-L7

76C

0.412

103656625

KS23825-L9

Dimensions - in (mm)

Telpower Specialty Fuses

——

A

0.445"

(11.30mm)

0.320"

(8.13mm)

1.125"

(28.58mm)

0.830"

(21.08mm)

0.280"

(7.11mm)

2.685"

(68.20mm)

0.190"

(4.83mm)

0.325"

(8.26mm)

0.620"

(15.75mm)

0.800"

(20.32mm)

——

A

Telecom Protection Products

T

elecom

Protection Products

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

440

Comprehensive UL 1449 3

rd

 

Edition recognized surge 
protection solutions for North 
American applications.

Surge Protection
Made Simple™

UL 508A Applications

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Surge Protective Devices

UL Type 1 NEMA 4X SPDs

SurgePOD HEAVY DUTY (Black Label) ...................442-445
SurgePOD PRO (Grey Label) ...................................446-448

UL DIN-Rail

High SCCR SPDs

1-Pole

Type 2

BSPM_S2G ...............................449-450

2-Pole

Type 2

BSPM_S3G ...............................451-452

3-Pole

Type 2

BSPM_WYG/DLG......................453-454

4-Pole

Type 2

BSPM_WYNG/HLG ...................455-456

Low Voltage AC/DC Power

1-Pole

Type 2

BSPM_LV...................................457-458

Low-Voltage AC/DC Control

2-Pole

Type 3

BSPH2A_LV...............................459-460

IEC DIN-Rail

Class I

2-Pole

Class I

BSPS_TN/TT .............................461-462

3-Pole

Class I

BSPS_TNC ................................463-464

4-Pole

Class I

BSPS_TNS/TT ...........................465-466

Class II

1-Pole

Class II

BSPM_TN / BSPG_NPE............467-468

2-Pole

Class II

BSPM_TN / BSPH_TT...............469-470

3-Pole

Class II

BSPM_TNC ...............................471-472

4-Pole

Class II

BSPM_TNS / BSPH_TT ............473-474

Solar Power Photovoltaic (PV) DIN-Rail

Lightning Arrester

1-Pole

PV Advance Lightning Arrester / 
BSPS_PV ..................................................475-476

Overvoltage Surge Protective Devices

2-Module

PV HEAVY DUTY SPD / 
BSPH2_PV ................................477-478

3-Module

PV HEAVY DUTY SPD / 
BSPH_YPV ................................479-480

3-Module

PV PRO SPD / BSPP_YPV........481-482

Wind Power IEC DIN-Rail

Class I

1-pole

Class I

BSPS_WE..................................483-484

Class II

1-Pole

Class II

BSPM_WE / BSPS_WE.............485-486

2-Pole

Class II

BSPM_WE / BSPH_WE ............487-488

3-Pole

Class II

BSPM_WE .................................489-490

4-Pole

Class II

BSPM_WE / BSPH_WE ............491-492

UL 4978 Data Signal SPDs

DIN-Rail BNC/Coaxial Cable    BSPD5BNCD_ .......493-494
In-Line BNC/Coaxial Cable      BSPD5BNCSI ........495-496
DIN-Rail RJ45/Ethernet Cable  BSPD48RJ45 .........497-498
DIN-Rail Universal 4 Wire         BSPD_DIN_............499-501

Surge Protective Overvoltage Device Modules

SurgePod™ Series, 150 to 550Vac MCOV ...........502-503

DIN-Rail TVS Series with Holder ..................................504

441

Surge Protection

Devices

Overvoltage
Protective Devices

Scan this tag to get product information

about the New Bussmann Surge

Protection products for UL, PV, IEC, Wind

Power and Telecom applications.

Scan this tag to get access to the 

Surge Protective Devices

Cross Reference Search.

RED 

indicates

NEW 

information

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

442

Overvoltage Devices

S

URGE

P

ROTECTION

M

ADE

S

IMPLE

™ 

FOR

C

OMMERCIAL

& I

NDUSTRIAL

A

PPLICATIONS

S

URGE

POD™ HEAVY DUTY SPD 

FOR

UL 1449 3

rd

Edition Listed Loadside and Lineside Protection

2-1/16”

2-1/16”

1-11/16”

1-11/16”

4-1/8”

3-3/16”

4-1/16”

3-3/8”

7/8”

1-1/16” Dia.

NEMA 4X Rated Heavy Duty

Type 1 UL Listed SPD

Description

The Bussmann SurgePOD™ HEAVY DUTY is a Type 1 UL

Listed 1449 3

rd

Edition surge protective device suitable for

installation on both the loadside or lineside of the service

entrance overcurrent protective device.

Available in voltage and system specific versions to match

electrical system and equipment requirements. The SurgePOD

HEAVY DUTY delivers optimum surge protection using

advanced patent pending SurgePOD™ module featuring 

thermal disconnect technology that eliminates the need for

additional overcurrent protection.

Parallel connection to the electrical system permits the

SurgePOD HEAVY DUTY SPD to be installed on 

any

ampacity

panel.

• Type 1 UL 1449 3

rd

Edition Listed SPDs are easily selected

and installed on the loadside or lineside of the service

entrance overcurrent protective device

• Patented Bussmann SurgePOD module technology 

eliminates the need for additional fusing

• Voltage specific models precisely match and protect 

electrical systems and equipment up to 600Vac

• Compact UV resistant NEMA 4X for indoor or outdoor 

applications

easy

ID™ LED status indicator provides surge protection 

status at a glance

Dimensions - in

SPH50SP1120SN

SPH50SP1240SN

SPH50SP1347SN

SPH50SP2120SNG

SPH50SP2240SNG

SPH50SP2347SNG

SPH50SP2240PN

SPH50SP2480PN

SPH50SP3240PNG

SPH50SP3480PNG

SPH50SP3240DLG

SPH50SP3480DLG

SPH50SP4240HLG

SPH50SP4480HLG

SPH50SP3208WYG

SPH50SP3480WYG

SPH50SP3600WYG

SPH50SP4208WYNG

SPH50SP4480WYNG

SPH50SP4600WYNG

easy

ID™ LED

Status Indicator

Type 1 SPD Part Number System

SPH

50S

PX XXX XXX

SPH = Product Series

Surge Protection Heavy Duty

Surge Rating

50S = 50kA max discharge current

No of Wires/Poles

P1 = 1

P2 = 2

P3 = 3

P4 = 4

Rated System Voltage

120, 208, 240, 347, 480, 600Vac

System

SN = Single-Phase 2 Wire, 2 Connection Points

SNG = Single-Phase 2 Wire + G, 3 Connection Points

PN = Split-Phase 3 Wire , 3 Connection Points

PNG = Split-Phase 3 Wire + G, 4 Connection Points

DLG = Three-Phase Delta 3 Wire + G, 4 Connection Points

HLG = Three-Phase Highleg Delta 4 Wire + G, 5 Connection Points

WYG = Three-Phase Wye 3 Wire, 4 Connection Points

WYNG = Three-Phase Wye 3 Wire + G, 5 Connection Points

SPD Type 2

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

443

Surge Protection

Devices

SurgePOD™ HEAVY DUTY Technical Information

Nominal

Max. Continuous

System

Operating AC 

Connection

Catalog Number

Voltage

Voltage (MCOV) (V

C

)

System Type

Points

SPH50SP1120SN

120V

150V

Single-Phase 2 Wire

2

SPH50SP1240SN

240V

320V

Single-Phase 2 Wire

2

SPH50SP1347SN

347V

420V

Single-Phase 2 Wire

2

SPH50SP2120SNG

120V

150V

Single-Phase 2 Wire + G

3

SPH50SP2240SNG

240V

320V

Single-Phase 2 Wire + G

3

SPH50SP2347SNG

347V

420V

Single-Phase 2 Wire + G

3

SPH50SP2240PN

120/240V

150V

Split-Phase 3 Wire

3

SPH50SP2480PN

240/480V

320V

Split-Phase 3 Wire

3

SPH50SP3240PNG

120/240V

150V

Split-Phase 3 Wire + G

4

SPH50SP3480PNG

240/480V

320V

Split-Phase 3 Wire + G

4

SPH50SP3240DLG

240V

320V

Three-Phase Delta 3 Wire + G

4

SPH50SP3480DLG

480V

550V

Three-Phase Delta 3 Wire + G

4

SPH50SP4240HLG

120/240V

150/320V

Three-Phase Highleg Delta 4 Wire + G

5

SPH50SP4480HLG

240/480V

320/550V

Three-Phase Highleg Delta 4 Wire + G

5

SPH50SP3208WYG

208V

150V

Three-Phase Wye 3 Wire + G

4

SPH50SP3480WYG

480V

320V

Three-Phase Wye 3 Wire + G

4

SPH50SP3600WYG

600V

420V

Three-Phase Wye 3 Wire + G

4

SPH50SP4208WYNG

208Y/120V

150V

Three-Phase Wye 4 Wire + G

5

SPH50SP4480WYNG

480Y/277V

320V

Three-Phase Wye 4 Wire + G

5

SPH50SP4600WYNG

600Y/347V

420V

Three-Phase Wye 4 Wire + G

5

Specifications (for all SurgePOD HD units)

Values

Short Circuit Current Rating (SCCR)

200kA

Nominal Discharge Current (8x20μs) In

20kA

Max. Discharge Current (8x20μs) Imax

50kA

Response Time tA

<25ns

Frequency

50/60Hz

Operating State/Fault Indication

Bi-Color LED - Green  (good) / Red (replace)

Conductor Length / Guage

18 inches, 10 AWG Stranded Tinned Copper

Mounting

Chase Nipple / Bracket*

Enclosure / Flammability Ratings

NEMA 4X - UL 94-5VA

Degree of Protection (Installed State)

IP20 (finger-safe)

SPD Install Location

Indoor/Outdoor

Circuit Location

Lineside or Loadside of service entrance overcurrent protective device

Standard

UL 1449 3

rd

Edition Type 1 Listed SPD

Agency Information 

cULus, CSA**, RoHS Compliant

Product Warranty

5 Years***

Operating Temperature

-40˚C to +85˚C

Maximum Operating Altitude

16,000FT

* Customer-supplied bracket.

** 600V Wye versions not CSA Certified.

*** See 

B

ussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/Surge.

SurgePOD™ HEAVY DUTY Technical Information

† 600V Wye versions are not CSA Certified.

Overvoltage Devices

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

444

Overvoltage Devices

Rated System

MCOV

Voltage Protection Ratings (VPRs)

Catalog Number

Voltage (V

o

)

(V

C

)

L-N

L-L

L-G

N-G

SPH50SP1120SN

120V

150V

700

SPH50SP1240SN

240V

320V

1200

SPH50SP1347SN

347V

420V

1500

SPH50SP2120SNG

120V

150V

700

1200

700

SPH50SP2240SNG

240V

320V

1200

2500

1200

SPH50SP2347SNG

347V

420V

1500

2500

1500

SPH50SP2240PN

120V/240V

150V

700

1200

SPH50SP2480PN

240V/480V

320V

1200

2500

SPH50SP3240PNG

120V/240V

150V

700

1200

1200

700

SPH50SP3480PNG

240V/480V

320V

1200

2500

2500

1200

SPH50SP3240DLG

240V

320V

2500

1200

SPH50SP3480DLG

480V

550V

3000

1800

SPH50SP4240HLG

120/240V

150V/320V

700/1200

1200/2500

1200/2500

700/1200

SPH50SP4480HLG

240/480V

320V/550V

1200/1800

2500/3000

2500/3000

1200/1800

SPH50SP3208WYG

208V

150V

1200

700

SPH50SP3480WYG

480V

320V

2500

1200

SPH50SP3600WYG

600V

420V

2500

1500

SPH50SP4208WYNG

208Y/120V

150V

700

1200

1200

700

SPH50SP4480WYNG

480Y/277V

320V

1200

2500

2500

1200

SPH50SP4600WYNG

600Y/347V

420V

1500

2500

2500

1500

Voltage Protection Ratings (VPRs)

easy

ID™ LED Status Indicator

The 

easy

ID™ LED status indicator will illuminate when the unit is

properly installed and the system or equipment being protected is

energized. The following LED color/status indicates:

GREEN LED = Good

The circuit is energized and 

protected

.

RED LED = Replace

The circuit is 

energized

and

unprotected

.

The unit 

needs

replacing.

LED is Out / Unlit:

• The circuit is most likely deenergized

• The unit’s leads are disconnected

• The unit is damaged

Authorized personnel should follow all prescribed lockout/tagout and safety procedures in troubleshooting 

the cause for the above conditions. Opening SurgePOD HEAVY DUTY enclosure will void UL listing and warranty.

Tighten locknut to

20.3 Lb-In (2.3N•m)

For NEMA 4X installation,
install appropriate customer
supplied gasket between 
SurgePOD™ HEAVY DUTY
SPD and enclosure wall.

Mounting

SurgePOD HEAVY DUTY is a panel mount device. It may also

be mounted using a customer supplied bracket or directly

onto a female threaded conduit fitting.

† 600V Wye versions are not CSA Certified.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

445

Surge Protection

Devices

Wiring Connections

Black
Black

White

L1 (Black)

L2 (Black)

N (White)

120V (L-N) / 240V (L1-L2), 

240V (L-N) / 480V (L1-L2)

Single Phase (Split) Center Tap

SPH50SP2240PN,

SPH50SP2480PN

Black
Black

Green

White

Orange

L3 (Black)

L2 (Orange)

Highleg

L1 (Black)

N (White)

GND (Green)

120V (L1 / L3-N) / 240V (L-L),

240V (L1 / L3-N) / 480V (L-L)

4 Wire Highleg Delta + Ground

SPH50SP4240HLG,

SPH50SP4480HLG

L (Black)

N (White)

Black

White

120, 240, 347V (L-N) 

2 Wire

120, 240, 347V (L-N)

2 Wire + Ground

SPH50SP1120SN,

SPH50SP1240SN,

SPH50SP1347SN

L (Black)

N (White)
GND (Green)

Black

Green

White

SPH50SP2120SNG,

SPH50SP2240SNG,

SPH50SP2347SNG

Black

Black
Black

Green

White

GND (Green)

L2 (Black)

N (White)

L3 (Black)

L1 (Black)

SPH50SP4208WYNG,

SPH50SP4480WYNG,

SPH50SP4600WYNG

120V (L-N) / 208V (L-L),

127V (L-N) / 220V (L-L), 

277V (L-N) / 480V (L-L), 

347V (L-N) / 600V (L-L)

4 Wire Wye + Ground

L1 (Black)

L2 (Black)
L3 (Black)

GND (Green)

SPH50SP3240DLG,

SPH50SP3480DLG

Black

Black
Black

Green

240, 480V (L-L)

3 Wire Delta + Ground

Black

Black
Black

Green

L1 (Black)

L3 (Black)

L2 (Black)

GND (Green)

SPH50SP3208WYG,

SPH50SP3480WYG,

SPH50SP3600WYG

208, 480, 600V (L-L)

3 Wire Wye + Ground

Black
Black

Green

White

L1 (Black)

L2 (Black)

N (White)

GND (Green)

120V (L-N) / 240V (L1-L2), 

240V (L-N) / 480V (L1-L2)

Single Phase (Split) Center Tap + Ground

SPH50SP3240PNG,

SPH50SP3480PNG

Must be installed within 10 feet (3m) of a bonded 

neutral-ground connection per IEEE C62.41-1991

For installations at or less than 10 feet (3m) 

from the transformer.

For installation when located greater than 10 feet (3m) of a 

bonded neutral-ground connection.

For installation when located greater than 10 feet (3m) 

of a bonded neutral-ground connection.

Single-Phase

Two-Pole with Neutral

Two-Pole with Neutral + Ground

Wye + Ground

Wye with Neutral + Ground

Delta + Ground

Highleg Delta

Single-Phase + Ground

Overvoltage Devices

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

446

Overvoltage Devices

S

URGE

P

ROTECTION

M

ADE

S

IMPLE

™ 

FOR

L

IGHT

C

OMMERCIAL

& R

ESIDENTIAL

A

PPLICATIONS

S

URGE

POD™ PRO SPD 

FOR

UL 1449 3

rd

Edition Listed Loadside and Lineside Protection

2-1/16”

2-1/16”

1-11/16”

1-11/16”

4-1/8”

3-3/16”

4-1/16”

3-3/8”

7/8”

1-1/16” Dia.

NEMA 4X Rated Pro

Type 1 UL Listed SPD

Description

The Bussmann SurgePOD™ PRO is a Type 1 UL Listed 1449

3

rd

Edition surge protective device suitable for installation on

both the loadside or lineside of the service entrance 

overcurrent protective device.

Available in popular voltage and system specific versions to

match common residential and light commercial electrical 

system and equipment requirements. The SurgePOD PRO

delivers superior surge protection using MOV thermal 

disconnect technology that eliminates the need for additional

overcurrent protection.

Parallel connection to the electrical system permits the

SurgePOD PRO SPD to be installed on 

any

ampacity panel.

• Type 1 UL 1449 3

rd

Edition Listed SPDs are easily selected

and installed on the loadside or lineside of the service

entrance overcurrent protective device

• Voltage specific models precisely match and protect 

electrical systems and equipment better than 

“one-size-fits-all” SPDs

• Thermal disconnect technology eliminates the need for

additional fusing

• Compact UV resistant NEMA 4X enclosure for indoor or 

outdoor applications

easy

ID™ LED status indicator provides surge protection 

status at a glance

Dimensions - in

SPP40SP1120SN

SPP40SP2240PN

SPP40SP3240DLG

SPP40SP3480DLG

SPP40SP3208WYG

SPP40SP3480WYG

easy

ID™ LED

Status Indicator

Type 1 SPD Part Number System

SPP

40S

PX XXX XXX

SPP = Product Series

Surge Protection PRO

Surge Rating

40S = 40kA max discharge current

No of Wires/Poles

P1 = 1

P2 = 2

P3 = 3

P4 = 4

Rated System Voltage

120, 208, 240, 480Vac

System

SN = Single-Phase 2 Wire, 2 Connection Points

PN = Split-Phase, 3 Wire, 3 Connection Points

DLG = Three-Phase Delta 3 Wire + G, 4 Connection Points

WYG = Three-Phase Wye 3 Wire, 4 Connection Points

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

447

Surge Protection

Devices

Nominal System

MCOV

Voltage Protection Ratings (VPRs)

Catalog Number

Voltage

(V

C

)

L-N

L-L

L-G

SPP40SP1120SN

120V

150V

700

SPP40SP2240PN

120V/240V

150V

700

1200

SPP40SP3240DLG

240V

320V

2500

1200

SPP40SP3480DLG

480V

550V

3000

1800

SPP40SP3208WYG

208V

150V

1200

700

SPP40SP3480WYG

480V

320V

2500

1200

Voltage Protection Ratings (VPRs)

Specifications (for all SurgePOD PRO units)

Values

Short Circuit Current Rating (SCCR)

200kA

Nominal Discharge Current (8x20μs) In

10kA

Max. Discharge Current (8x20μs) Imax

40kA

Response Time (ns) tA

<25ns

Frequency

50/60Hz

Operating State/Fault Indication

Bi-Color LED - Green  (good) / Red (replace)

Conductor Length / Guage

18 inches, 10 AWG Stranded Tinned Copper

Mounting

Chase Nipple / Bracket*

Enclosure / Flammability Ratings

NEMA 4X - UL 94-5VA

Degree of Protection (Installed State)

IP20 (finger-safe)

SPD Install Location

Indoor/Outdoor

Circuit Location

Lineside or Loadside of service entrance overcurrent protective device

Standard

UL 1449 3

rd

Edition Type 1 Listed SPD

Agency Information

cULus, RoHS Compliant

Product Warranty

2 Years**

Operating Temperature

-40˚C to +65˚C

Maximum Operating Altitude

12000FT

* Customer-supplied bracket.

** See 

B

ussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/Surge.

SurgePOD™ PRO Technical Information

Nominal

Max. Continuous

System

Operating AC 

Connection

Catalog Number

Voltage

Voltage (MCOV) (V

C

)

System Type

Points

SPP40SP1120SN

120V

150V

Single-Phase 2 Wire

2

SPP40SP2240PN

120/240V

150V

Split Phase 3 Wire

3

SPP40SP3240DLG

240V

320V

Three-Phase Delta 3 Wire + G

4

SPP40SP3480DLG

480V

550V

Three-Phase Delta 3 Wire + G

4

SPP40SP3208WYG

208V

150V

Three-Phase Wye 3 Wire + G

4

SPP40SP3480WYG

480V

320V

Three-Phase Wye 3 Wire + G

4

Overvoltage Devices

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

448

Overvoltage Devices

Wiring Connections

L (Black)

N (White)

Black

White

120V (L-N) 

2 Wire

SPP40SP1120SN

L1 (Black)

L2 (Black)
L3 (Black)

GND (Green)

SPP40SP3240DLG,

SPP40SP3480DLG

Black

Black
Black

Green

240, 480V (L-L)

3 Wire Delta + Ground

Black

Black
Black

Green

L1 (Black)

L3 (Black)

L2 (Black)

GND (Green)

SPP40SP3208WYG,

SPP40SP3480WYG

208, 480V (L-L)

3 Wire Wye + Ground

Must be installed within 10 feet (3m) of a bonded 

neutral-ground connection per IEEE C62.41-1991

Single-Phase

Wye + Ground

Delta + Ground

easy

ID™ LED Status Indicator

The 

easy

ID™ LED status indicator will illuminate when the unit is

properly installed and the system or equipment being protected is

energized. The following LED color/status indicates:

GREEN LED = Good

The circuit is energized and 

protected

.

RED LED = Replace

The circuit is 

energized

and

unprotected

.

The unit 

needs

replacing.

LED is Out / Unlit:

• The circuit is most likely deenergized

• The unit’s leads are disconnected

• The unit is damaged

Authorized personnel should follow all 

prescribed lockout/tagout and safety 

procedures in troubleshooting the cause for

the above conditions. Opening SurgePOD

PRO enclosure will void UL listing and 

warranty.

Tighten locknut to

20.3 Lb-In (2.3N•m)

For NEMA 4X installation,
install appropriate customer
supplied gasket between 
SurgePOD™ PRO
SPD and enclosure wall.

Mounting

SurgePOD PRO is a panel mount device. It may also be

mounted using a customer supplied bracket or directly onto a

female threaded conduit fitting.

Black
Black

White

L1 (Black)

L2 (Black)

N (White)

120V (L-N) / 240V (L1-L2), 

Single Phase (Split) Center Tap

SPP40SP2240PN,

For installations at or less than 10 feet (3m) 

from the transformer.

Two-Pole with Neutral

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

449

Surge Protection

Devices

Overvoltage Devices

UL DIN-Rail SPD - High SCCR

BSPM_ _ _ _S2G

Specifications

Description

The Bussmann single pole UL modular surge arresters for
120, 240 and 347Vac single-phase systems feature local,

easy

ID™ visual indication and optional remote contact 

signaling. The unique module locking system fixes the 
protection module to the base part. Modules can be easily
replaced without tools by simply depressing the release 
buttons. Integrated mechanical coding between the base and
protection module ensures against installing an incorrect
replacement module.

Features

• Surge arrester according to UL 1449 3

rd

Edition, Type 2

Component Assembly helps meet UL 508A requirements

• Heavy-duty zinc oxide varistors for high discharge capacity
• "Thermo Dynamic Control" SPD monitoring device ensures

high reliability against surge events

• Module locking system with module release button makes

module replacement easy without tools

• Up to 200kA Short-Circuit Current Rating (SCCR) makes

higher 

assembly

SCCR ratings possible

• Optional remote signaling of all protection modules makes

status monitoring easy and accurate in any monitoring
scheme

• No upstream overcurrent protection necessary to make

installation easier and more economical

• Vibration and shock tested according to EN 60068-2 to 

withstand harsh environments

Optional Remote Signaling Contact

The remote signaling contact versions have a floating
changeover contact for use as a break or make contact for
easy adoption in any monitoring application.

BSPM1120S2G, BSPM1240S2G, BSPM1347S2G*

Shown with optional remote contact signaling

Shown with optional remote contact signaling

Circuit Diagram

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPM1347S2GR

12

11

14

L

Gnd/N

12

11

14

Thermal 
Disconnector

Optional Remote
Signal Contact

MOV

Data Sheet: 2149

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

450

Overvoltage Devices

UL DIN-Rail SPD - High SCCR

Single Pole BSP UL Series Installation Instructions - Document 3A1636RevA

O

RDERING

I

NFORMATION

Nominal System Voltage

120Vac

240, 277 or 240 & 277Vac

347Vac

Max. Continuous Operating AC Voltage (MCOV) [V

C

]

275Vac

385Vac

600Vac

Catalog Numbers:

Without Remote Signaling

BSPM1120S2G

BSPM1240S2G

BSPM1347S2G

With Remote Signaling

BSPM1120S2GR

BSPM1240S2GR

BSPM1347S2GR

Replacement Module

MOV Technology

BPM275UL

BPM385UL

BPM600UL

S

PECIFICATIONS

Rated Voltage 

120-127Vac

240-277Vac

347Vac

Voltage Protection Rating V

PR

1kV

1.5kV

2kV

SCCR

200kA

200kA

125kA

Nominal Discharge Current  I

n

(kA)

20kA

Max. Discharge Current  I

max

(kA)

40kA

Response Time  t

A

_

<25 ns

Frequency

50/60Hz

Number of Poles

1

Number of Wires/Connection Points

2 Wires / 2 Connection Points

Operating State/Fault Indication

Green (good) / Red (replace)

Cross-Sectional Area (min.)

14AWG - Cu Stranded, Solid or Fine

Cross-Sectional Area (max.)

2AWG - Cu Solid or Stranded / 4AWG - Cu Fine

Terminal Torque

45 lb-in

For Mounting On

35mm DIN Rail per to EN 60715

Enclosure Material

Thermoplastic, UL 94V0

Degree of Protection

IP20 (finger-safe)

Location Category

Indoor

Capacity

1 Mods, DIN 43880

Application

UL Type 2 Component Assembly

Standard

UL 1449, 3

rd

Edition

Agency Information

cURus, CSA, RoHS Compliant

Product Warranty

Five Years*

R

EMOTE

C

ONTACT

S

IGNALING

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.5A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals

60/75°C Max. 1.5mm

2

/14AWG Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Part Numbers for all systems BSPM1120S2G, BSPM1240S2G, BSPM1347S2G

120, 277, 347Vac 2 Wire Wye Systems

120, 240, 347Vac 2 Wire Systems

L1 
L2 

L3 

Data Sheet: 2149

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

451

Surge Protection

Devices

Overvoltage Devices

UL DIN-Rail SPD - High SCCR

BSPM_ _ _ _S3G

Description

The Bussmann 2-pole UL modular surge arresters for
120/240, 120/208, 127/254, 240, 240/480, 277/480 and
480Vac (split-phase) systems feature local, 

easy

ID™ visual

indication and optional remote contact signaling. The unique
module locking system fixes the protection module to the base
part. Modules can be easily replaced without tools by simply
depressing the release buttons. Integrated mechanical coding
between the base and protection module ensures against
installing an incorrect replacement module.

Features

• Surge arrester according to UL 1449 3

rd

Edition, Type 2

Component Assembly helps meet UL 508A requirements

• Heavy-duty zinc oxide varistors for high discharge capacity
• "Thermo Dynamic Control" SPD monitoring device ensures

high reliability against surge events

• Module locking system with module release button make

module replacement easy without tools

• Up to 200kA Short-Circuit Current Rating (SCCR) make

higher 

assembly

SCCR ratings possible

• Optional remote signaling of all protection modules make

status monitoring easy and accurate in any monitoring
scheme

• No upstream overcurrent protection necessary to make

installation easier and more economical

• Vibration and shock tested according to EN 60068-2 to 

withstand harsh environments

Optional Remote Signaling Contact

The remote signaling contact versions have a floating
changeover contact for use as a break or make contact for
easy adoption in any monitoring application.

BSPM2240S3G, BSPM2480S3G*

Shown with optional remote contact signaling

Shown with optional remote contact signaling

Circuit Diagram

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

*For remote signaling contact, add “R” suffix to the part number,

E.g., BSPM2480S3GR

L2

L1

12

11

14

Gnd/N

Gnd/N

12

11

14

Thermal 
Disconnector

Optional Remote
Signal Contact

MOV

Data Sheet: 2150

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

452

Overvoltage Devices

UL DIN-Rail SPD - High SCCR

O

RDERING

I

NFORMATION

Nominal System Voltage

120/240, 240Vac

240/480Vac

Max. Continuous Operating Voltage  MCOV

[L-G/L-L]

275/550Vac

385/770Vac

Catalog Numbers:

Without Remote Signaling

BSPM2240S3G

BSPM2480S3G

With Remote Signaling

BSPM2240S3GR

BSPM2480S3GR

Replacement Module

MOV Technology

BPM275UL

BPM385UL

S

PECIFICATIONS

120-127Vac

240-480Vac

Rated Voltage

240-254Vac

480Vac

240Vac

Voltage Protection Rating  V

PR

[L-G/L-L]

1kV/1.8kV

1.5kV/2.5kV

Nominal Discharge Current  I

n

(kA)

20kA

Max. Discharge Current  I

max

(kA)

40kA

Response Time  t

A

_

<25 ns

SCCR

200kA

Frequency

50/60Hz

Number of Poles

2

Number of Wires/Connection Points

2 Wires or 3 Wires / 3 Connection Points

Operating State/Fault Indication

Green (good) / Red (replace)

Cross-Sectional Area (min.)

14AWG - Cu Stranded, Solid or Fine

Cross-Sectional Area (max.)

2AWG - Cu Solid or Stranded, 4AWG - Cu Fine

Terminal Torque

45 lb-in

For Mounting On

35mm DIN-Rail per EN 60715

Enclosure Material

Thermoplastic, UL 94V0

Degree of Protection

IP20 (finger-safe)

Location Category

Indoor

Capacity

2 mods, DIN 43880

Application

UL Type 2 Component Assembly

Standard

UL 1449, 3

rd

Edition

Agency Information

cURus, CSA, RoHS Compliant

Product Warranty

Five Years*

R

EMOTE

C

ONTACT

S

IGNALING

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.5A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals

60/75°C Max. 1.5mm

2

/14AWG  Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

120/240V, 240/480Vac

Single Phase (Split) Center Tap

BSPM2240S3G, BSPM2480S3G

2 Wire Corner Grounded Delta

2 Wire Ungrounded Delta

240, 480Vac

BSPM2440S3G, BSPM2480S3G

120/208V, 277/480Vac

3 Wire Wye System

BSPM2240S3G, BSPM2480S3G

L1 
L2 

L3 

L1 

L2 

L1 

L2 

Data Sheet: 2150

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

453

Surge Protection

Devices

Overvoltage Devices

UL DIN-Rail SPD - High SCCR

BSPM_ _ _ _WYG, BSPM_ _ _ _DLG

Description

The Bussmann 3-pole UL modular surge arresters for 240 and
480 3-phase Delta, and 120/208, 277/480 and 347/600Vac 
3-phase Wye systems feature local, 

easy

ID™ visual indication

and optional remote contact signaling. The unique module
locking system fixes the protection module to the base part.
Modules can be easily replaced without tools by simply
depressing the release buttons. Integrated mechanical coding
between the base and protection module ensures against
installing an incorrect replacement module.

Features

• Surge arrester according to UL 1449 3

rd

Edition, Type 2

Component Assembly helps meet UL 508A requirements

• Heavy-duty zinc oxide varistors for high discharge capacity
• "Thermo Dynamic Control" SPD monitoring device ensures

high reliability against surge events

• Module locking system with module release button make

module replacement easy without tools

• Up to 200kA Short-Circuit Current Rating (SCCR) make

higher 

assembly

SCCR ratings possible

• Optional remote signaling of all protection modules make

status monitoring easy and accurate in any monitoring
scheme

• No upstream overcurrent protection necessary to make

installation easier and more economical

• Vibration and shock tested according to EN 60068-2 to 

withstand harsh environments

Optional Remote Signaling Contact

The remote signaling contact versions have a floating
changeover contact for use as a break or make contact,
according to circuit concept.

BSPM3208WYG, BSPM3480WYG), BSPM3600WYG,

BSPM3240DLG, BSPM3480DLG*

Shown with optional remote contact signaling

Shown with optional remote contact signaling

Circuit Diagrams

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

*For remote signaling contact, add “R” suffix to the part number,

E.g., BSPM3480DLGR

12

11

14

L1

L2

L3

Gnd

Gnd

12

11

14

Thermal 
Disconnector

Optional Remote
Signal Contact

MOV

Data Sheet: 2151

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

454

Overvoltage Devices

UL DIN-Rail SPD - High SCCR

O

RDERING

I

NFORMATION

Nominal System Voltage

120/208Vac

240Vac

277/480Vac

480Vac

347/600Vac

Max. Continuous Operating AC Voltage  MCOV  [L-G/L-L]

275/550Vac

275/550Vac

385/770Vac

600/1200Vac

600/1200Vac

Catalog Numbers:

Without Remote Signaling

BSPM3208WYG

BSPM3240DLG

BSPM3480WYG

BSPM3480DLG

BSPM3600WYG

With Remote Signaling

BSPM3208WYGR BSPM3240DLGR BSPM3480WYGR BSPM3480DLGR BSPM3600WYGR

Replacement Module

MOV Technology

BPM275UL

BPM275UL

BPM385UL

BPM600UL

BPM600UL

S

PECIFICATIONS

Rated Voltage

120-127Vac,

240Vac

277/480Vac

480Vac

347/600Vac

208-220Vac

Voltage Protection Rating V

PR

[L-G/L-L]

1kV/1.8kV

1kV/1.8kV

1.5kV/2.5kV

2kV/4kV

2kV/4kV

SCCR

200kA

200kA

200kA

125kA

125kA

Nominal Discharge Current  I

n

(kA)

20kA

Max. Discharge Current  I

max

(kA)

40kA

Response Time  t

A

_

<25 ns

Frequency

50/60Hz

Number of Poles

3

Number of Wires/Connection Points

3 Wires / 4 Connection Points

Operating State/Fault Indication

Green (good) / Red (replace)

Cross-Sectional Area (min.)

14AWG - Cu Stranded, Solid or Fine

Cross-Sectional Area (max.)

2AWG - Cu Solid or Stranded, 4AWG - Cu Fine

Terminal Torque

45 lb-in

For Mounting On

35mm DIN-Rail per to EN 60715

Enclosure Material

Thermoplastic, UL 94V0

Degree of Protection

IP20 (finger-safe)

Location Category

Indoor

Capacity

3 Mods, DIN 43880

Application

UL Type 2 Component Assembly

Standard

UL 1449, 3

rd

Edition

Agency Information

cURus, CSA, RoHS Compliant

Product Warranty

Five Years*

R

EMOTE

C

ONTACT

S

IGNALING

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.5A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for 

60/75°C Max. 1.5mm

2

/14AWG  Solid/Flexible

Remote Contact Signal Terminals
Ordering Information

Order from Catalog Numbers Above

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

240, 480Vac

Delta 3-Phase, 3 Wire + Ground

BSPM3240DLG, BSPM3480DLG

208, 480, 600Vac

208V, 480V, 600Vac

Wye 3-Phase, 3 Wire + Ground

BSPM3208WYG, BSPM3480WYG, BSPM3600WYG

L1 

L2 
L3 

L1 
L2 

L3 

L1 
L2 

L3 

Data Sheet: 2151

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

455

Surge Protection

Devices

Overvoltage Devices

UL DIN-Rail SPD - High SCCR

BSPM_ _ _ _WYNG, BSPM_ _ _ _HLG

Description

The Bussmann 4-pole UL modular surge arresters for
120/240, 240/480Vac 3-phase Highleg Delta and 120/208,
127/220, 277/480 and 347/600Vac 3-phase 4 wire Wye 
systems feature local, 

easy

ID™ visual indication and optional

remote contact signaling. The unique module locking system
fixes the protection module to the base part. Modules can be
easily replaced without tools by simply depressing the release
buttons. Integrated mechanical coding between the base and
protection module ensures against installing an incorrect
replacement module.

Features

• Surge arrester according to UL 1449 3

rd

Edition, Type 2

Component Assembly helps meet UL 508A requirements

• Heavy-duty zinc oxide varistors for high discharge capacity
• "Thermo Dynamic Control" SPD monitoring device ensures

high reliability against surge events

• Module locking system with module release button make

module replacement easy without tools

• Up to 200kA Short-Circuit Current Rating (SCCR) make

higher 

assembly

SCCR ratings possible

• Optional remote signaling of all protection modules make

status monitoring easy and accurate in any monitoring
scheme

• No upstream overcurrent protection necessary to make

installation easier and more economical

• Vibration and shock tested according to EN 60068-2 to 

withstand harsh environments

Optional Remote Signaling Contact

The remote signaling contact versions have a floating
changeover contact for use as a break or make contact for
easy adoption in any monitoring 
application.

BSPM4208WYNG, BSPM4480WYNG, BSPM4600WYNG,

BSPM4240HLG, BSPM4480HLG*

Shown with optional remote contact signaling

Shown with optional remote contact signaling

Circuit Diagram

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

*For remote signaling contact, add “R” suffix to the part number,

E.g., BSPM4480HLGR

12

11

14

L2

N

L1

L3

Gnd

Gnd

12

11

14

Thermal 
Disconnector

Optional Remote
Signal Contact

MOV

Data Sheet: 2152

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

456

Overvoltage Devices

UL DIN-Rail SPD - High SCCR

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

120/240V, 240/480Vac

Highleg Delta, 3-Phase, 4 Wire + Ground

BSPM4240HLG, BSPM4480HLG

120/208V, 127/220V, 277/480V, 347/600Vac

Wye 3-Phase, 4 Wire + Ground

BSPM4208WYNG, BSPM4480WYNG,

BSPM4600WYNG

L1 

L2 

(Highleg) 

L3 

L1 
L2 

L3 

O

RDERING

I

NFORMATION

Nominal System Voltage

120/208Vac, 

120/240Vac

240/480Vac

277/480Vac

347/600Vac

127/220Vac

Max. continuous operating AC voltage MCOV [L-N]/[L-G]

275/550Vac

275/550Vac

385/770Vac

385/660Vac

600/875Vac

[N-G]/[L-L]

275/550Vac

275/550Vac

385/770Vac

275/770Vac

275/1200Vac

[H-N]/[H-G]

- -

275/550Vac

600/985Vac

- -

- -

[H-L]

- -

550Vac

985Vac

- -

- -

Catalog Numbers:

Without Remote Signaling

BSPM4208WYNG

BSPM4240HLG

BSPM4480HLG

BSPM4480WYNG

BSPM4600WYNG

With Remote Signaling

BSPM4208WYNGR

BSPM4240HLGR

BSPM4480HLGR BSPM4480WYNGR

BSPM4600WYNGR

Replacement Modules

Module Positions L1 or L3

BPM275UL

BPM275UL

BPM385UL

BPM385UL

BPM600UL

MOV Technology 

L2

BPM275UL

BPM275UL

BPM600UL

BPM385UL

BPM600UL

Four (4) Total Required

N

BPM275UL

BPM275UL

BPM385UL

BPM275UL

BPM275UL

S

PECIFICATIONS

Rated Voltage

120/208Vac,

120/240Vac

240/480Vac

277/480Vac

347/600Vac

127/220Vac

[L-N/L-G]

1kV/1.8kV

1kV/1.8kV

1.5kV/2.5kV

1.5kV/2.5kV

2kV/3kV

Voltage Protection Rating  V

PR

[N-G/L-L]

1kV/1.8kV

1kV/1.8kV

1.5kV/2.5kV

1kV/2.5kV

1kV/4kV

[H-N/H-G]

- -

1kV/1.8kV

2kV/3kV

- -

- -

[H-L]

- -

1.8kV

3kV

- -

- -

SCCR

200kA

200kA

125kA

200kA

125kA

Nominal Discharge Current  I

n

(kA)

20kA

Max. Discharge Current  I

max

(kA)

40kA

Response Time  t

A

_

< 25 ns

Frequency

50/60Hz

Number of Poles

4

Number of Wires/Connection Points

4 Wires / 5 Connection Points

Operating State/Fault Indication

Green (good) / Red (replace)

Cross-Sectional Area (min.)

14AWG - Cu Stranded, Solid or Fine

Cross-Sectional Area (max.)

2AWG - Cu Solid or Stranded, 4AWG - Cu Fine

Terminal Torque

45 lb-in

For Mounting On

35mm DIN-Rail per to EN 60715

Enclosure Material

Thermoplastic, UL 94V0

Degree of Protection

IP20 (finger-safe)

Location Category

Indoor

Capacity

4 Mods, DIN 43880

Application

UL Type 2 Component Assembly

Standard

UL 1449, 3

rd

edition

Agency Information

cURus, CSA, RoHS Compliant

Product Warranty

Five Years*

R

EMOTE

C

ONTACT

S

IGNALING

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.5A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for 

60/75°C Max. 1.5mm

2

/14AWG  Solid/Flexible

Remote Contact Signal Terminals
Ordering Information

Order from Catalog Numbers Above

Data Sheet: 2152

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

457

Surge Protection

Devices

Overvoltage Devices

UL DIN-Rail SPD - Low Voltage AC/DC Power 

BSPM1A_ _ _ _LV

Shown with optional remote contact signaling

Module Circuit Diagrams - 

Shown with optional remote contact

signaling

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

BSPM1A48D60LV, BSPM1A75D100LV,

BSPM1A150D200LV,

BSPM1A275D350LV, BSPM1A320D420LV,
BSPM1A385D500LV, BSPM1A440D585LV,

BSPM1A600D600LV*

Shown with optional remote contact signaling

*For remote signaling contact, add “R” suffix to the part number,

E.g., BSPM1A150D200LVR

Description

The Bussmann UL Type 2 48Vac/60Vdc, 75Vac/100Vdc,
120Vac/200Vdc, 275VAc/350Vdc, 320Vac/420Vdc,
385Vac/500Vdc, 440Vac/585Vdc and 600Vac/dc single pole,
modular surge arresters feature local, 

easy

ID™ visual 

indication and optional remote contact signaling. The unique
module locking system fixes the protection module to the base
part. Modules can be easily replaced without tools by simply
depressing the release buttons. Integrated mechanical coding
between the base and protection module ensures against
installing an incorrect replacement module.

LV Power System Arresters

The features of these single-pole devices are for use as a 
single device or in combination with other devices for AC and
DC voltage systems.

• Surge arrester according to UL 1449 3

rd

Edition, Type 2

Component Assembly helps meet UL 508A requirements*

• Proven MOV technology for reliable surge protection
• "Thermo Dynamic Control" SPD monitoring device ensures

high reliability against surge events

• Module locking system with module release button make

module replacement easy without tools

• Optional remote signaling of all protection modules make

status monitoring easy and accurate in any monitoring
scheme

• No upstream overcurrent protection necessary to make

installation easier and more economical

• Vibration and shock tested according to EN 60068-2 to 

withstand harsh environments

Optional Remote Signaling Contact

The remote signaling contact versions have a floating
changeover contact for use as a break or make contact for
easy adoption in any monitoring application.

* Except as noted in data sheets.

Data Sheet: 2056

MOV

Thermal Disconnector

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

458

Overvoltage Devices

UL DIN-Rail SPD - Low Voltage AC/DC Power 

Data Sheet: 2056

Ordering Information - All Models

SPD according to EN 61643-11

Type 2

SPD according to IEC 61643-1

Class II

Response time [tA]

_

< 25 ns

TOV characteristics

Withstand

Operating temperature range [TU]

-40°C to +80°C

Operating state/fault indication

Green (good) / Red (replace)

Number of ports

1

Cross-sectional area (min.)

1.5mm

2

/14AWG solid/flexible

Cross-sectional area (max.)

35mm

2

/1AWG stranded/25mm

2

/2AWG flexible

For mounting on

35mm DIN-Rail per EN 60715

Enclosure material

Thermoplastic, UL 94V0

Location category

Indoor

Degree of protection

IP20

Capacity

1 Mod., DIN 43880

Product Warranty

Five Years**

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.5A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for

60/75°C Max. 1.5mm

2

/14AWG Solid/Flexible

Remote Contact Signal Terminals
Ordering Information

Order from Catalog Numbers Above

Ordering Information - 48Vac/60Vdc to 275Vac/350Vdc

System Voltage

48Vac/60Vdc

75Vac/100Vdc

120Vac/200Vdc

275Vac/350Vdc

Catalog Numbers:

Without Remote Signaling

BSPM1A48D60LV

BSPM1A75D100LV

BSPM1A150D200LV

BSPM1A275D350LV

(Base + Modules)

With Remote Signaling

BSPM1A48D60LVR

BSPM1A75D100LVR

BSPM1A150D200LVR

BSPM1A275D350LVR

Replacement Modules

BPMA48D60LV

BPMA75D100LV

BPMA150D200LV

BPMA275D350LV

Specifications

Max. continuous operating AC voltage [VC]

48Vac

75Vac

150Vac

275Vac

Max. continuous operating DC voltage [VC]

60Vdc

100Vdc

200Vdc

350Vdc

Nominal discharge current (8/20 μs) [In]

10kA

10kA

15kA

20kA

Max. discharge current (8/20 μs) [Imax]

25kA

40kA

40kA

40kA

Voltage protection level [VPR]

_

< 0.3 kV

_

< 0.4kV

_

< 0.7kV

_

< 1.25kV

Voltage protection level at 5 kA [VPR]

_

< 0.25kV

_

< 0.35kV

_

< 0.55kV

_

< 1kV

Temporary overvoltage (TOV)

70V / 5 sec.

90V / 5 sec.

175V / 5 sec.

335V / 5 sec

Agency Information*

- -

UL / cUL,

UL / cUL,

UL / cUL,

CSA, KEMA

CSA, KEMA

CSA, KEMA

Ordering Information - 320Vac/420Vdc to 600Vac/dc

System Voltage

320Vac/420Vdc

385Vac/500Vdc

440Vac/585Vdc

600Vac/600Vdc

Catalog Numbers:

Without Remote Signaling

BSPM1A320D420LV

BSPM1A385D500LV

BSPM1A440D585LV

BSPM1A600D600LV

(Base + Modules)

With Remote Signaling

BSPM1A320D420LVR

BSPM1A385D500LVR

BSPM1A440D585LVR

BSPM1A600D600LVR

Replacement Modules

BPMA320D420LV

BPMA385D500LV

BPMA440D585LV

BPMA600D600LV

Specifications

Max. continuous operating AC voltage [VC]

320Vac

385Vac

440Vac

600Vac

Max. continuous operating DC voltage [VC]

420Vdc

500Vdc

585Vdc

600Vdc

Nominal discharge current (8/20 μs) [In]

20kA

20kA

20kA

15kA

Max. discharge current (8/20 μs) [Imax]

40kA

40kA

40kA

30kA

Voltage protection level [VPR]

_

< 1.5kV

_

< 1.75kV

_

< 2kV

_

< 2.5kV

Voltage protection level at 5 kA [VPR]

_

< 1.2kV

_

< 1.35kV

_

< 1.7kV

_

< 2kV

Temporary overvoltage (TOV)

335V / 5 sec.

385V / 5 sec.

580V / 5 sec.

600V / 5 sec.

Agency Information*

UL / cUL,

UL / cUL,

UL / cUL,

UL / cUL,

CSA, KEMA

CSA, KEMA

CSA, KEMA

CSA, KEMA

* Standards information not applicable to DC ratings.

** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

459

Surge Protection

Devices

Overvoltage Devices

UL DIN-Rail SPD - Low Voltage AC/DC Control 

BSPH2A_ _ _ _LV(R)

BPH2A24D24LV       BPH2A48D48LV    BPH2A60D60LV
BPH2A150D150LV   BPH2A230D230LV

Shown with optional remote contact signaling

Module Circuit Diagrams

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

Data Sheet: 2057

Shown with optional remote contact signaling

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPH2A230D230LVR

Specifications

Description

The Bussmann UL Type 3 24Vac/dc, 48Vac/dc, 60Vac/dc,
120Vac/dc and 230Vac/dc, two-pole, modular surge arresters
feature local, 

easy

ID™ visual indication and optional remote

contact signaling. The unique module locking system fixes the
protection module to the base part. Modules can be easily
replaced without tools by simply depressing the release 
buttons. Integrated mechanical coding between the base and
protection module ensures against installing an incorrect
replacement module.

LV System Arresters

The features of these two-pole devices are for use in 
coordination with other upstream SPDs in UL 508A
Applications*.

• Surge arrester according to UL 1449 3

rd

Edition, 

Type 3 Component Assembly helps meet UL 508A 
requirements

• Proven MOV and GDT hybrid technology for reliable surge

protection

• "Thermo Dynamic Control" SPD monitoring device ensures

high reliability against surge events

• Module locking system with module release button make

module replacement easy without tools

• Optional remote signaling of all protection modules make

status monitoring easy and accurate in any monitoring
scheme

• No upstream overcurrent protection necessary to make

installation easier and more economical

• Vibration and shock tested according to EN 60068-2 to 

withstand harsh environments

Optional Remote Signaling Contact

The remote signaling contact versions have a floating
changeover contact for use as a break or make contact for
easy adoption in any monitoring application.

* UL 1449 3

rd

Edition not applicable to DC voltages.

MOV

Gas Discharge Tube (single)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

460

Overvoltage Devices

UL DIN-Rail SPD - Low Voltage AC/DC Power 

Data Sheet: 2057

Ordering Information

System Voltage

24Vac/dc

48Vac/dc

60Vac/dc

120Vac/dc

230Vac/dc

Max. Continuous operating AC voltage (MCOV) [V

C

]

30Vac/dc

60Vac/dc

75Vac/dc

150Vac/dc

255Vac/dc

Catalog Numbers:

Without Remote Signaling BSPH2A24D24LV

BSPH2A48D48LV

BSPH2A60D60LV

BSPH2A150D150LV

BSPH2A230D230LV

(Base + Modules)

With Remote Signaling

BSPH2A24D24LVR BSPH2A48D48LVR BSPH2A60D60LVR BSPH2A150D150LVR BSPH2A230D230LVR

Replacement Modules

BPHA24D24LV

BPHA48D48LV

BPHA60D60LV

BPHA150D150LV

BPHA230D230LV

Specifications

Nominal AC voltage [V

o

]

24V

48V

60V

120V

230V

Max. continuous operating AC voltage [V

C

]

30V

60V

75V

150V

255V

Max. continuous operating DC voltage [V

C

]

30V

60V

75V

150V

255V

Nominal load current AC [I

L

]

25A

25A

25A

25A

25A

Nominal discharge current (8/20 μs) [I

n

]

1kA

1kA

2kA

2kA

3kA

Total discharge current (8/20 μs) [L+N-Gnd] [I

total

]

2kA

2kA

4kA

4kA

5kA

Combined impulse [U

OC

]

2kV

2kV

4kV

4kV

6kV

Combined impulse [L+N-Gnd] [U

OC

total]

4kV

4kV

8kV

8kV

10kV

Voltage protection level [L-N] [V

PR

]

_

< 180V

_

< 350V

_

< 400V

_

< 640V

_

< 1250V

Voltage protection level [L/N-Gnd] [V

PR

]

_

< 630V

_

< 730V

_

< 730V

_

< 800V

_

< 1500V

Temporary overvoltage (TOV) [L-N] 

--

--

--

--

335V / 5 sec.

Temporary overvoltage (TOV) [L/N-Gnd]

--

--

--

--

400V / 5 sec.

Temporary overvoltage (TOV) [L+N-Gnd]

--

--

--

--

1200V + V

0

/ 20

TOV characteristics [L-N]

--

--

--

--

Withstand

TOV characteristics [L/N-Gnd]

--

--

--

--

Withstand

TOV characteristics [L+N-Gnd]

--

--

--

--

Failure

SPD according to EN 61643-11

Type 3

SPD according to IEC 61643-1

Class III

Response time [L-N] [t

A

]

_

< 25 ns

Response time [L/N-Gnd] [t

A

]

_

< 100 ns

Operating temperature range [T

U

]

-40°C to +80°C

Operating state/fault indication

Green (good) / Red (replace)

Number of ports

1

Cross-sectional area (min.)

0.5mm

2

/18AWG solid/flexible

Cross-sectional area (max.)

4mm

2

/10AWG solid/2.5mm

2

/12AWG flexible

For mounting on

35mm DIN rail per EN 60715

Enclosure material

Thermoplastic, UL 94V0

Location category

Indoor

Degree of protection

IP20

Capacity

1 Mod., DIN 43880

Agency Information*

UL / cUL, CSA, KEMA

Product Warranty

Five Years**

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.5A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for

60/75°C Max. 1.5mm

2

/14AWG Solid/Flexible

Remote Contact Signal Terminals
Ordering Information

Order from Catalog Numbers Above

* Standards information not applicable to DC ratings.

** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

461

Surge Protection

Devices

Overvoltage Devices

IEC Class I DIN-Rail SPD

BSPS_ _ _ _TN, BSPS_ _ _ _TT

Description

The Bussmann IEC Class I 230V, two-pole, modular 
combined lightning, current and surge arresters feature local,

easy

ID™ visual indication and optional remote contact 

signaling. The unique module locking system fixes the 
protection module to the base part. Modules can be easily
replaced without tools by simply depressing the release 
buttons. Integrated mechanical coding between the base and
protection module ensures against installing an incorrect
replacement module.230V models are offered with MCOV
rating of 255V.

TN System Arresters

The features of these two-pole devices are for use as a 
modular combined lightning and current arrester and surge
arrester for use in single TN- systems (“2-0” circuit).

TT System Arrester

Provides a current arresting means for use in single 
TT- systems (“1-1” circuit).

Remote Signaling Contact

The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.

Remote Signal 

Contact Available

Visual Status Indication

BSPS2255TN

Shown with optional 

remote contact signaling

Shown with optional remote contact signaling

BSPS2255TT

Shown with optional 

remote contact signaling

Circuit Diagrams

Dimensions - mm

Spark Gap Trigger

Creepage Discharge Spark Gap

Data Sheet: 1163

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPS2255TNR

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

462

Overvoltage Devices

IEC Class I DIN-Rail SPD

Ordering Information

System Voltage/Poles

230V/2

230V/2

Max. Continuous operating AC voltage (MCOV) [U

C

]

255V

255V

Catalog Numbers:

Without Remote Signaling

BSPS2255TN

BSPS2255TT

With Remote Signaling

BSPS2255TNR

BSPS2255TTR

Replacement Modules:

MOV technology

(2X) BPS255IEC

(1X) BPS255IEC

Spark Gap technology

- -

(1X) BPS50NPEIEC*

Specifications

Specific energy [L+N-PE] [W/R]

625.00 kJ/ohms

- -

Lightning impulse current (10/350 μs) [L, N-PE] [I

imp

]

25kA

25/50kA Is [L-N]/[N-PE]

Specific energy [L,N-PE] [W/R]

156.25 kJ/ohms

156.25kJ/ohms/
625.00 kJ/ohms

Voltage protection level [L-PE]/[N-PE] [U

P

]

<

_ 1.5 kV/<

_ 1.5 kV

- -

Voltage protection level [L-N]/[N-PE] [U

P

]

-  -

<

_ 1.5kV/<

_ 1.5kV

Follow current extinguishing capability AC [I

fi

]

50kA rms

- -

Follow current extinguishing capability [L-N]/[N-PE] [I

fi

]

- -

50kA rms/100A rms

Temporary overvoltage (TOV) [N-PE] [U

T

]

- -

1200V/200 ms

SPD according to EN 61643-11/... IEC 61643-1

Type 1/Class I

Energy-coordinated protection effect with regard to the terminal equipment

Type 1 + Type 2

Energy-coordinated protection effect with regard to the terminal equipment (<

_ 5m)

Type 1 + Type 2 + Type 3

Nominal AC voltage [U

N

]

230V

Lightning impulse current (10/350 μs) [L+N-PE] [I

total

]

50kA

Nominal discharge current (8/20 μs) [I

n

]

25/50kA

Follow current limitation/Selectivity

no tripping of a 20A gL/gG fuse up to 50kA rms (prosp.)

Response time [t

A

]

<

_ 100 ns

Max. Backup fuse (L) up to I

K

<

_ 50kA rms

315A gL/gG

Max. Backup fuse (L) for I

K

> 50kA rms

200A gL/gG

Max. Backup fuse (L-L )

125A gL/gG

Temporary overvoltage (TOV) [L-N] [U

T

]

440V/5 sec.

TOV characteristics

withstand

Operating temperature range (parallel connection) [TU

P

]

-40°C to +80°C

Operating temperature range (series connection) [TU

S

]

-40°C to +60°C

Operating temperature range [parallel]/[continuity] [TU]

-40°C to +80°C/-40°C to +60°C

Operating state/fault indication

green (good)/red (replace)

Number of ports

1

Cross-sectional area (L, L , N, N , PE,

) [min.]

10mm

2

solid/flexible

Cross-sectional area (L, N, PE) [max.]

50mm

2

/1AWG stranded-35mm

2

/2AWG flexible

Cross-sectional area (L , N ,

) [max.]

35mm

2

/2AWG stranded-25mm

2

/4AWG flexible

For mounting on

35mm DIN Rail per EN 60715

Enclosure material

Thermoplastic, UL 94V0

Location category

Indoor

Degree of protection

IP20

Capacity

4 mods., DIN 43880

Standards Information

KEMA

Product Warranty

Five Years**

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.1A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals

60/75°C Max. 1.5mm

2

/14AWG  Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* N-PE Surge arrester for location between neutral conductor and protective conductor 

in TT systems.

** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbuss-

mann.com/surge.

Recommended Bussmann NH DIN Size Back Up Fuses

Size

NH Fuse Part Number

Size

NH Fuse Part Number

00

125NHG00B (max L-L)

02

125NHG02B (max L-L)

0

125NHG0B (max L-L)

02

200NHG02B (max L Ik >50kA)

01

125NHG01B (max L-L)

2

315NHG2B (max L _

<50kA)

1

200NHG1B (max L Ik >50kA)

03

315NHG03B (max L _

<50kA)

Data Sheet: 1163

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

463

Surge Protection

Devices

Overvoltage Devices

IEC Class I DIN-Rail SPD

BSPS_ _ _ _TNC

Remote Signal 

Contact Available

Visual Status Indication

Description

The Bussmann IEC Class I 230V, three-pole, modular 
combined lightning, current and surge arresters feature local,

easy

ID™ visual indication and optional remote contact 

signaling. The unique module locking system fixes the 
protection module to the base part. Modules can be easily
replaced without tools by simply depressing the release 
buttons. Integrated mechanical coding between the base and
protection module ensures against installing an incorrect
replacement module.

230V models are offered with a MCOV rating of 255V.

TNC System Arrester

The features of these three-pole devices are for use in 
TN-C 230/400V systems (“3-0” circuit) against surges.

Remote Signaling Contact

The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.

Shown with optional remote contact signaling

Dimensions - mm

BSPS3255TNC

Shown with optional remote contact signaling

Circuit Diagrams

Data Sheet: 1164

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPS3255TNCR

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

464

Overvoltage Devices

IEC Class I DIN-Rail SPD

Ordering Information

System Voltage/Poles

230/400V/3

Max. Continuous operating AC voltage (MCOV) [U

C

]

255V

Catalog Numbers:

Without Remote Signaling

BSPS3255TNC

With Remote Signaling

BSPS3255TNCR

Replacement Module

MOV technology

BPS255IEC

Specifications

SPD according to EN 61643-11/... IEC 61643-1

Type 1/Class I

Energy-coordinated protection effect with regard to the terminal equipment

Type 1 + Type 2

Energy-coordinated protection effect with regard to the terminal equipment (<

_ 5m)

Type 1 + Type 2 + Type 3

Nominal AC voltage [U

N

]

230/400V

Lightning impulse current (10/350 μs) [L1+L2+L3-PEN] [I

total

]

75kA

Specific energy [L1+L2+L3-PEN] [W/R]

1.40 MJ/ohms

Lightning impulse current (10/350 μs) [L-PEN] [I

imp

]

25kA

Specific energy [L-PEN] [W/R]

156.25kJ/ohms

Nominal discharge current (8/20 μs) [I

n

]

25/75kA

Voltage protection level [U

P

]

<

_ 1.5kV

Follow current extinguishing capability AC [I

fi

]

50kA rms

Follow current limitation/Selectivity

no tripping of a 20A gL/gG fuse up to 50kA rms (prosp.)

Response time [t

A

]

<

_ 100 ns

Max. Backup fuse (L) up to IK = 50kA rms

315A gL/gG

Max. Backup fuse (L) for I

K

> 50kA rms

200A gL/gG

Max. Backup fuse (L-L )

125A gL/gG

Temporary overvoltage (TOV) [U

T

]

440V/5 sec.

TOV characteristics

withstand

Operating temperature range [parallel]/[continuity] [T

U

]

-40°C to +80°C/-40°C to +60°C

Operating state/fault indication

green (good)/red (replace)

Number of ports

1

Cross-sectional area (L1, L1 , L2, L2 , L3, L3 , PEN, 

) [min.]

10mm

2

solid/flexible

Cross-sectional area (L1, L2, L3, PEN) [max.]

50mm

2

/1AWG stranded-35mm

2

/2AWG flexible

Cross-sectional area (L1 , L2 , L3 ,

) [max.]

35mm

2

/2AWG stranded-25mm

2

/4AWG flexible

Mounting

35mm DIN rail per to EN 60715

Enclosure material

Thermoplastic, UL 94V0

Location category

Indoor

Degree of protection

IP20

Capacity

6 mods., DIN 43880

Standards Information

KEMA

Product Warranty

Five Years*

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.1A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals

60/75°C Max. 1.5mm

2

/14AWG  Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Recommended Bussmann NH DIN Size Back Up Fuses

Size

NH Fuse Part Number

Size

NH Fuse Part Number

00

125NHG00B (max L-L)

02

125NHG02B (max L-L)

0

125NHG0B (max L-L)

02

200NHG02B (max L Ik >50kA)

01

125NHG01B (max L-L)

2

315NHG2B (max L _

<50kA)

1

200NHG1B (max L Ik >50kA)

03

315NHG03B (max L _

<50kA)

Data Sheet: 1164

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

465

Surge Protection

Devices

Overvoltage Devices

IEC Class I DIN-Rail SPD

BSPS_ _ _ _TNS, BSPS_ _ _ _TT

Remote Signal 

Contact Available

Visual Status Indication

Description

The Bussmann IEC Class I 230V, four-pole, modular 
combined lightning, current and surge arresters feature local,

easy

ID™ visual indication and optional remote contact 

signaling. The unique module locking system fixes the 
protection module to the base part. Modules can be easily
replaced without tools by simply depressing the release 
buttons. Integrated mechanical coding between the base and
protection module ensures against installing an incorrect
replacement module.

230V models are offered with MCOV ratings of 255V.

TNS System Arresters

The features of these four-pole devices are for use in TNS
230/400V systems (“4-0” circuit) against surges.

TT System Arrester

Provides a current arresting means  between neutral 
conductor and protective conductor in TT 230/400V systems
(“3+1” circuit) against surges.

Remote Signaling Contact

The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.

Shown with optional remote contact signaling

Dimensions - mm

BSPS4255TNS

Shown with optional 

remote contact signaling

Circuit Diagrams

BSPS4255TT

Shown with optional 

remote contact signaling

Creepage Discharge Spark Gap

Spark Gap Trigger

Data Sheet: 1165

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPS4255TTR

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

466

Overvoltage Devices

IEC Class I DIN-Rail SPD

Ordering Information

System Voltage/Poles

230/400V/4

230/400V/4

Max. Continuous operating AC voltage (MCOV) [U

C

]

255V

255V

Catalog Numbers:

Without Remote Signaling

BSPS4255TNS

BSPS4255TT

With Remote Signaling

BSPS4255TNSR

BSPS4255TTR

Replacement Modules:

MOV technology

BPS255IEC

BPS255IEC

Spark Gap technology

- -

BPS100NPEIEC*

Specifications

SPD according to EN 61643-11/... IEC 61643-1

Type 1/Class I

Energy-coordinated protection effect with regard to the terminal equipment

Type 1 + Type 2

Energy-coordinated protection effect with regard to the terminal equipment (<

_ 5m)

Type 1 + Type 2 + Type 3

Nominal AC voltage [U

N

]

230/400V

Lightning impulse current (10/350 μs) [L1+L2+L3+N-PE] [I

total

]

100kA

Specific energy [L1+L2+L3+N-PE] [W/R]

2.50MJ/ohms

Lightning impulse current (10/350 μs) [L, N-PE] [I

imp

]

25kA

TNS system specific energy [L,N-PE] [W/R]

156.25kJ/ohms

TT system specific energy [L-N]/[N-PE] [W/R]

156.25kJ/ohms/2.50kJ/ohms

Nominal discharge current (8/20 μs) [I

n

]

25/100kA

Voltage protection level [L-PE]/[N-PE] [U

P

]

<

_ 1.5kV/<

_ 1.5kV

TNS system follow current extinguishing capability AC [I

fi

]

50kA rms

TT system follow current extinguishing capability AC [I

fi

]

50kA rms/100A rms

Follow current limitation/Selectivity

No tripping of a 20A gL/gG fuse up to 50kA rms (prosp.)

Response time [t

A

]

<

_ 100 ns

Max. Backup fuse (L) up to IK <

_ 50kA rms

315A gL/gG

Max. Backup fuse (L) for IK > 50kA rms

200A gL/gG

Max. Backup fuse (L-L )

125A gL/gG

Temporary overvoltage (TOV) [L-N] [U

T

]

440V/5 sec.

Temporary overvoltage (TOV) [N-PE] [U

T

]

1200V/200mS

TOV characteristics

Withstand

Operating temperature range [parallel]/[continuity] [T

U

]

-40°C to +80°C/-40°C to +60°C

Operating state/fault indication

green (good)/red (replace)

Number of ports

1

Cross-sectional area (L1, L1 , L2, L2 , L3, L3 , N, N , PE,

) [min.]

10mm

2

solid/flexible

Cross-sectional area (L1, L2, L3, N, PE) [max.]

50mm

2

/1AWG stranded-35mm

2

/2AWG flexible

Cross-sectional area (L1 , L2 , L3 , N ,

) [max.]

35mm

2

/2AWG stranded-25mm

2

/4AWG flexible

Mounting

35mm DIN Rail per EN 60715

Enclosure material

Thermoplastic,  UL 94V0

Location category

Indoor

Degree of protection

IP20

Capacity

8 mods., DIN 43880

Agency Information

KEMA

Product Warranty

Five Years**

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.1A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals

60/75°C Max. 1.5mm

2

/14AWG  Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.

** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Recommended Bussmann NH DIN Size Back Up Fuses

Size

NH Fuse Part Number

Size

NH Fuse Part Number

00

125NHG00B (max L-L)

02

125NHG02B (max L-L)

0

125NHG0B (max L-L)

02

200NHG02B (max L Ik >50kA)

01

125NHG01B (max L-L)

2

315NHG2B (max L _

<50kA)

1

200NHG1B (max L Ik >50kA)

03

315NHG03B (max L _

<50kA)

Data Sheet: 1165

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

467

Surge Protection

Devices

Overvoltage Devices

IEC Class II DIN-Rail SPD

BSPM_ _ _ _TN, BSPG_ _ _ _NPE

Remote Signal 

Contact Available

Visual Status Indication

Description

The Bussmann IEC Class II 275, 320, 385, 440 and 600V,
one-pole, modular surge arresters feature local, 

easy

ID™

visual indication and optional remote contact signaling. The
unique module locking system fixes the protection module to
the base part. Modules can be easily replaced without tools
by simply depressing the release buttons. Integrated
mechanical coding between the base and protection module
ensures against installing an incorrect replacement module.

Class II single-pole surge arrester models are offered with
MCOV ratings of 255, 275, 320, 385, 440 and 600V.

TN System Arresters

The features of these single-pole devices are for use as a
single device or in combination with other devices.

TT System Arrester

Provides a current arresting means between neutral 
conductor and protective conductor in TT systems, this
device helps ensure fulfilling the requirements for protection
of personnel and equipment in “3+1” and “1+1” circuits.

Remote Signaling Contact

The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.

BSPM1275TN
BSPM1320TN
BSPM1385TN
BSPM1440TN
BSPM1600TN

Shown with optional remote contact signaling

Module Circuit Diagrams -

Shown with optional remote contact signaling

Dimensions - mm

Data Sheet: 1166

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPM1275TNR

MOV

Thermal Disconnector

Gas Discharge Tube (single)

BSPG1255NPE(R)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

468

Overvoltage Devices

IEC Class II DIN-Rail SPD

* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.

** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Recommended Bussmann Back Up Fuses

DIN 

TT / TN System NH Fuse Part Numbers

Fuse Size

275, 320, 385, 440V

600V

00

125NHG00B

100NHG00B-690

0

125NHG0B

100NHG0B-690

01

125NHG01B

- -

1

- -

100NHG1B-690

02

125NHG02B

- -

2

- -

100NHG2B-690

Ordering Information

System Voltage/Poles

230V/1

230V/1

230V/1

400V/1

600V/1

230V/1*

Max. Continuous operating AC voltage (MCOV) [U

C

]

275V

320V

385V

440V

600V

255V

Catalog Numbers:

Without Remote Signaling

BSPM1275TN

BSPM1320TN

BSPM1385TN

BSPM1440TN

BSPM1600TN

BSPG1255NPE

(Base + Modules)

With Remote Signaling

BSPM1275TNR

BSPM1320TNR BSPM1385TNR

BSPM1440TNR

BSPM1600TNR BSPG1255NPER

Replacement Modules

BPM275IEC

BPM320IEC

BPM385IEC

BPM440IEC

BPM600IEC

BPG255NPE

Specifications

Line system type

TN / TT

TN / TT

TN / TT

TN

TN

TT

Max. Continuous operating DC voltage [U

C

]

350V

420V

500V

585V

600V

- -

Voltage protection level [U

P

]

<

_ 1.25kV

<

_ 1.5kV

<

_ 1.75kV

<

_ 2kV

<

_ 2.5kV

<

_ 1.5kV

Voltage protection level at 5kA [U

P

]

<

_ 1kV

<

_ 1.2kV

<

_ 1.35kV

<

_ 1.7kV

<

_ 2kV

- -

Max. mains-side overcurrent protection

125A gL/gG

125A gL/gG

125A gL/gG

125A gL/gG

100A gL-gG

- -

Short-circuit withstand capability for max. 

50kArms

25kArms

25kArms

25kArms

25kA rms

- -

mains-side overcurrent protection
Temporary overvoltage (TOV) [U

T

]

335V/5 sec.

335V/5 sec.

385V/5 sec.

580V/5 sec.

600V/5 sec.

1200V/200 ms

Response time [t

A

]

<

_ 25 ns

<

_ 25 ns

<

_ 25 ns

<

_ 25 ns

<

_ 25 ns

<

_ 100 ns

Follow current extinguishing capability [I

fi

]

- -

- -

- -

- -

- -

100Arms

Lightning impulse current (10/350 μs) [I

imp

]

- -

- -

- -

- -

- -

12kA

Nominal discharge current (8/20 μs) [I

n

]

20kA

20kA

20kA

20kA

15kA

20kA

Max. Discharge current (8/20 μs) [I

max

]

40kA

40kA

40kA

40kA

30kA

40kA

Standards Information

KEMA

KEMA, CSA

KEMA, CSA

KEMA, CSA

KEMA, CSA

KEMA

Capacity

1 mod., DIN 43880

SPD according to EN 61643-11

Type 2

SPD according to IEC 61643-1

Class II

TOV characteristics

Withstand

Operating temperature range [T

U

]

-40°C to +80°C

Operating state/fault indication

Green (good) / Red (replace)

Number of ports

1

Cross-sectional area (min.)

1.5mm

2

/14AWG solid/flexible

Cross-sectional area (max.)

35mm

2

/2AWG stranded-25mm

2

/4AWG flexible

Mounting

35mm DIN Rail per EN 60715

Enclosure material

Thermoplastic, UL 94V0

Location category

Indoor

Degree of protection

IP20

Product Warranty

Five Years**

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.1A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for 

60/75°C Max. 1.5mm

2

/14AWG  Solid/Flexible

Remote Contact Signal Terminals
Ordering Information

Order from Catalog Numbers Above

Data Sheet: 1166

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

469

Surge Protection

Devices

Overvoltage Devices

IEC Class II DIN-Rail SPD

BSPM_ _ _ _TN, BSPH_ _ _ _TT

Remote Signal 

Contact Available

Visual Status Indication

Description

The Bussmann IEC Class II 230V, two-pole, modular surge
arresters feature local, 

easy

ID™ visual indication and 

optional remote contact signaling. The unique module locking
system fixes the protection module to the base part. Modules
can be easily replaced without tools by simply depressing the
release buttons. Integrated mechanical coding between the
base and protection module ensures against installing an
incorrect replacement module.230V models are offered with
MCOV ratings of 255 and 275V.

TN System Arresters

The features of these single-pole devices are for use in 
single-phase 230V TN systems (“2-0” circuit).

TT System Arrester

The features of these single-pole devices are for use in 
single-phase 230V TT and TNS systems (“1-1” circuit).

Remote Signaling Contact

The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.

Shown with optional remote contact signaling

Circuit Diagrams

Dimensions - mm

BSPM2275TN

Shown with optional remote 

contact signaling

BSPH2275TT

Shown with optional remote 

contact signaling

MOV

Thermal Disconnector

Gas Discharge Tube (single)

Data Sheet: 1167

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPM2275TNR

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

470

Overvoltage Devices

IEC Class II DIN-Rail SPD

Ordering Information

System Voltage/Poles

230V/2

230V/2

Max. continuous operating AC voltage (MCOV) [U

C

]

275V

- -

Max. Continuous operating AC voltage (MCOV) [L-N] [U

C

]

-  -

275V

Max. Continuous operating AC voltage (MCOV) [N-PE] [U

C

]

-  -

255V

Catalog Numbers:

Without Remote Signaling

BSPM2275TN

BSPH2275TT

With Remote Signaling

BSPM2275TNR

BSPH2275TTR

Replacement Modules:

MOV Technology

BPM275IEC

BPM275IEC

Spark Gap technology

- -

BPSNPEIEC*

Specifications

Lightning impulse current (10/350 μs) [N-PE] [I

imp

]

-  -

12kA

Voltage protection level [U

P

]

<

_ 1.25kV

- -

Voltage protection level at 5kA [U

P

]

<

_ 1kV

- -

Voltage protection level [L-N] [U

P

]

-  -

<

_ 1.25kV

Voltage protection level [L-N] at 5kA [U

P

]

-  -

<

_ 1kV

Voltage protection level [N-PE] [U

P

]

-  -

<

_ 1.5kV

Follow current extinguishing capability [N-PE] [I

fi

]

- -

100A rms

Response time [t

A

]

<

_ 25 ns

- -

Response time [L-N] [t

A

]

-  -

<

_ 25 ns

Response time [N-PE] [t

A

]

-  -

<

_ 100 ns

Temporary overvoltage (TOV) [U

T

]

335V/5 sec.

- -

Temporary overvoltage (TOV) [L-N] [U

T

]

- -

335V/5 sec.

Temporary overvoltage (TOV) [N-PE] [U

T

]

- -

1200V/200 ms

SPD according to EN 61643-11

Type 2

SPD according to IEC 61643-1

Class II

Nominal discharge current (8/20 μs) [I

n

]

20kA

Max. discharge current (8/20 μs) [I

max

]

40kA

Max. mains-side overcurrent protection

125A gL/gG

Short-circuit withstand capability for max. mains-side overcurrent protection

50kA rms

Nominal AC voltage [U

N

]

230V

TOV characteristics

withstand

Operating temperature range [T

U

]

-40°C to +80°C

Operating state/fault indication

green (good)/red (replace)

Number of ports

1

Cross-sectional area (min.)

1.5mm2/14AWG solid/flexible

Cross-sectional area (max.)

35mm2/2AWG stranded-25mm2/4AWG flexible

Mounting

35mm DIN rail per EN 60715

Enclosure material

Thermoplastic, UL 94V0

Location category

Indoor

Degree of protection

IP20

Capacity

2 mods., DIN 43880

Standards Information

KEMA

Product Warranty

Five Years**

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.1A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals

60/75°C Max. 1.5mm

2

/14AWG  Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.

** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Recommended Bussmann Back Up Fuses

DIN Fuse Size

NH Fuse Part Number

00

125NHG00B

0

125NHG0B

01

125NHG01B

02

125NHG02B

Data Sheet: 1167

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

471

Surge Protection

Devices

Overvoltage Devices

IEC Class II DIN-Rail SPD

BSPM_ _ _ _TNC

Description

The Bussmann IEC Class II 120/240V and 230/400V, 
three-pole, modular surge arresters feature local, 

easy

ID™

visual indication and optional remote contact signaling. The
unique module locking system fixes the protection module to
the base part. Modules can be easily replaced without tools
by simply depressing the release buttons. Integrated
mechanical coding between the base and protection module
ensures against installing an incorrect replacement module.

120V models are offered with a MCOV rating of 150V.

230V models are offered with a MCOV rating of 275 or 385V.

TNC System Arresters

The features of these three-pole devices are for use in TN-C
120/240V or 230/400V systems (“3-0” circuit) against surges.

Remote Signaling Contact

The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.

BSPM3150TNC, BSPM3275TNC, BSPM3385TNC

Shown with optional remote contact signaling

Shown with optional remote contact signaling

Circuit Diagrams

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

MOV

Thermal Disconnector

Data Sheet: 1168

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPM3150TNCR

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

472

Overvoltage Devices

IEC Class II DIN-Rail SPD

O

RDERING

I

NFORMATION

System Voltage/Poles

120V/3

230V/3

230V/3

Max. Continuous operating AC voltage (MCOV) [U

C

]

150V

275V

385V

Catalog Numbers:

Without Remote Signaling

BSPM3150TNC

BSPM3275TNC

BSPM3385TNC

With Remote Signaling

BSPM3150TNCR

BSPM3275TNCR

BSPM3385TNCR

Replacement Module

MOV technology

BPM150IEC

BPM275IEC

BPM385IEC

S

PECIFICATIONS

Nominal AC voltage [U

N

]

120/240V

230/400V

230/400V

Voltage protection level [U

P

]

_

< 0.7kV

<

_ 1.25kV

_

< 1.75kV

Voltage protection level at 5kA [U

P

]

_

< 0.55kV

<

_ 1kV

_

< 1.35kV

Short-circuit withstand capability for max. mains-side overcurrent protection

50kArms

50kArms

25kArms

Temporary overvoltage (TOV) [U

T

]

175V/5 sec

335V/5 sec.

385V/5 sec

Nominal discharge current (8/20 μs) [I

n

]

15kA

20kA

20kA

Max. Discharge current (8/20 μs) [I

max

]

40kA

SPD according to EN 61643-11

Type 2

SPD according to IEC 61643-1

Class II

Response time [t

A

]

<

_ 25 ns

Max. mains-side overcurrent protection

125A gL/gG

TOV characteristics

withstand

Operating temperature range [T

U

]

-40°C to +80°C

Operating state/fault indication

Green (good)/Red (replace)

Number of ports

1

Cross-sectional area (min.)

1.5mm

2

/14AWG solid/flexible

Cross-sectional area (max.)

35mm

2

/2AWG stranded-25mm

2

/4AWG flexible

Mounting

35mm DIN rail per EN 60715

Enclosure material

Thermoplastic, UL 94V0

Location category

Indoor

Degree of protection

IP20

Capacity

3 mods., DIN 43880

Standards Information

KEMA

Product Warranty

Five Years*

R

EMOTE

C

ONTACT

S

IGNALING

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.1A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals

60/75°C Max. 1.5mm

2

/14AWG  Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Recommended Bussmann Back Up Fuses

DIN Fuse Size

NH Fuse Part Number

00

125NHG00B

0

125NHG0B

01

125NHG01B

02

125NHG02B

Data Sheet: 1168

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

473

Surge Protection

Devices

Overvoltage Devices

IEC Class II DIN-Rail SPD

BSPH_TNS, BSPH_TT

BSPM4275TNS

Shown with  optional remote contact signaling

BSPH4275TT, BSPH4320TT

BSPH4385TT

Shown with optional remote contact signaling

Shown with optional remote contact signaling

Circuit Diagrams

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

Description

The Bussmann IEC Class II 230/400V, four-pole, modular
surge arresters feature local, 

easy

ID™ visual indication and

optional remote contact signaling. The unique module locking
system fixes the protection module to the base part. Modules
can be easily replaced without tools by simply depressing the
release buttons. Integrated mechanical coding between the
base and protection module ensures against installing an
incorrect replacement module.

These 230V models are offered with MCOV ratings of 275,
320 or 385V.

TNS System Arrester

The features of these four-pole devices are for use in TNS
230/400V systems (“4-0” circuit) against surges.

TT System Arrester

The features of these four-pole devices are for use in TT and
TN-S 230/400V systems (“3+1” circuit) against surges.

Remote Signaling Contact

The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.

MOV

Thermal Disconnector

Gas Discharge Tube (single)

Data Sheet: 1169

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPH4275TTR

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

474

Overvoltage Devices

IEC Class II DIN-Rail SPD

O

RDERING

I

NFORMATION

System Voltage/Poles

230V/4

230V/4

230V/4

230V/4

Max. continuous operating AC voltage (MCOV) [U

C

]

275V

-  -

-  -

-  -

Max. continuous operating AC voltage (MCOV) [L-N] [U

C

]

- -

275V

320V

385V

Max. continuous operating AC voltage [N-PE] [U

C

]

- -

255V

255V

255V

Catalog Numbers:

Without Remote Signaling

BSPM4275TNS BSPH4275TT

BSPH4320TT

BSPH4385TT

With Remote Signaling

BSPM4275TNSR BSPH4275TTR BSPH4320TTR BSPH4385TTR

Replacement Modules:

MOV technology

BPM275IEC

BPM275IEC

BPM320IEC

BPM385IEC

Spark Gap technology

- -

BPSNPEIEC*

BPSNPEIEC*

BPSNPEIEC*

S

PECIFICATIONS

Lightning impulse current (10/350 μs) [N-PE] [I

imp

]

- -

12kA

12kA

12kA

Voltage protection level [U

P

]

<

_ 1.25kV

- -

- -

- -

Voltage protection level at 5kA [UP]

<

_  1kV

-  -

-  -

-  -

Voltage protection level [L-N] [UP]

-  -

<

_ 1.25kV

<

_ 1.5kV

<

_ 1.75kV

Voltage protection level [L-N] at 5kA [UP]

-  -

<

_ 1kV

<

_ 1.2kV

<

_ 1.35kV

Voltage protection level [N-PE] [UP]

-  -

<

_ 1.5kV

<

_ 1.5kV

<

_ 1.5kV

Follow current extinguishing capability [N-PE] [Ifi]

- -

100Arms

100Arms

100Arms

Response time [tA]

<

_ 25 ns

- -

- -

- -

Response time [L-N] [tA]

-  -

<

_ 25 ns

<

_ 25 ns

<

_ 25 ns

Response time [N-PE] [tA]

-  -

<

_ 100 ns

<

_ 100 ns

<

_ 100 ns

Temporary overvoltage (TOV) [UT]

335V/5 sec.

- -

- -

- -

Temporary overvoltage (TOV) [L-N] [UT]

- -

335V/5 sec.

335V/5 sec.

385V/5 sec.

Temporary overvoltage (TOV) [N-PE] [UT]

- -

1200V/200 ms 1200V/200 ms 1200V/200 ms

Short-circuit withstand capability for max. 

50kArms

50kArms

25kArms

25kArms

mains-side overcurrent protection
SPD according to EN 61643-11

Type 2

SPD according to IEC 61643-1

Class II

Nominal AC voltage [UN]

230/400V

Nominal discharge current (8/20 μs) [In]

20kA

Max. discharge current (8/20 μs) [Imax]

40kA

Max. mains-side overcurrent protection

125A gL/gG

TOV characteristics

withstand

Operating temperature range [TU]

-40°C to +80°C

Operating state/fault indication

green (good)/red (replace)

Number of ports

1

Cross-sectional area (min.)

1.5mm

2

/14AWG solid/flexible

Cross-sectional area (max.)

35mm

2

/2AWG stranded-25mm

2

/4AWG flexible

Mounting

35mm DIN rail per EN 60715

Enclosure material

Thermoplastic, UL 94V0

Location category

Indoor

Degree of protection

IP20

Capacity

4 mods., DIN 43880

Standards Information

KEMA

Product Warranty

Five Years**

R

EMOTE

C

ONTACT

S

IGNALING

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.1A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals

60/75°C Max. 1.5mm

2

/14AWG  Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* N-PE Surge arrester module for location between neutral conductor and protective conductor in TT systems.

** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Recommended Bussmann Back Up Fuses

DIN Fuse Size

NH Fuse Part Number

00

125NHG00B

0

125NHG0B

01

125NHG01B

02

125NHG02B

Data Sheet: 1169

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

475

Surge Protection

Devices

Overvoltage Devices

Photovoltaic DIN-Rail Lightning SPD

BSPS_ _ _ _PV

Description

The Bussmann combined lightning current and surge arrester
(SPD Class I according to IEC 61643-1) is for use in 
photovoltaic power supply systems.
• Prewired combined lightning current and surge arrester for

use in photovoltaic generator circuits

• For use in photovoltaic installations up to 1000V U

CPV

• High lightning current discharge capacity using spark gap

technology

• Maximum system availability due to spark gap technology

with DC current extinction

Module Circuit Diagrams

Dimensions - mm

Data Sheet: 2148

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

476

Overvoltage Devices

Photovoltaic DIN-Rail Lightning SPD

Data Sheet: 2148

Ordering Information

Max. PV System Voltage

1000Vdc

Catalog Number:

BSPS31000PV

Specifications

SPD Classification according to EN 61643-11

Type 1

SPD Classification according to IEC 61643-1

Class I

Max. PV voltage [U

CPV

] of the PV generator

1000V

Max. Continuous operating DC voltage [U

max

DC]

1000V

Min. Continuous operating DC voltage  [U

min

DC]

100V

Follow current extinguishing capability DC  [I

fi

DC]

100A

Nominal discharge current (8/20 μs)   [I

n

]

100kA

Lightning impulse current (10/350 μs) [L+/L- -> PE]  [I

imp

]

50kA

Specific energy [L+/L- -> PE]  [W/R]

625.00 kJ/ohms

Lightning impulse current (10/350 μs) [L+ -> L-]  [I

imp

]

25kA

Specific energy [L+ -> L-]  [W/R]

156.25 kJ/ohms

Voltage protection level [L+ -> L-]  [U

p

]

_

< 3.3kV

Voltage protection level [(L+/L-) -> PE]  [U

p

]

_

< 4kV

Operating current  [I

IN

DC]

_

< 5mA

Response time [L+ -> L-]  [t

A

]

_

< 20 ns

Protective conductor current  [I

PE

]

_

< 1μA

Operating temperature range  [T

u

]

-40°C to +60°C

Number of ports

1

Cross-sectional area (min.)

10mm

2

/6AWG solid/flexible

Cross-sectional area (max.)

50mm

2

/2AWG stranded/ 35mm

2

/1AWG flexible

Mounting

35mm DIN rail per EN 60715

Enclosure material

Thermoplastic, UL 94V0

Place of installation

Indoor

Degree of protection

IP-20

Capacity

8 Mods., DIN 4

Product Warranty

Five Years*

* See Bussmann document 3A1502 on the web at www.cooperbussmann.com.

L+

L-

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

477

Surge Protection

Devices

Overvoltage Devices

Photovoltaic DIN-Rail SPD

BSPH2_ _ _ _PV

Description

The Bussmann modular Surge Protective Device (SPD) (with
two-step DC switching device) features 

easy

ID™ visual 

indication and optional remote contact signaling (floating
changeover contact) for use in photovoltaic systems.

This complete surge protective device is suitable for all PV
systems in accordance with UL 1449 3

rd

Edition and IEC

60364-7-712. Includes a five year limited warranty.

This prewired solution consist of a base and locking modules
that feature a combined disconnection and short-circuiting
(shunting) device with safe electrical isolation to prevent fire
damage due to DC arcs. An integrated DC fuse allows safe
module replacement without arc formation.

In case of insulation faults in the generator circuit, a reliable
and tested fault-resistant circuit prevents damage to the surge 
protective devices.

The green and red visual indicator flags show the module 
protective status (green = good, red = replace). Apart from this
visual indication, the remote signaling option features a three
terminal floating changeover contact that can be used as a
make or break contact depending on the particular monitoring
system design employed.

Remote Signal 

Contact Available

Visual Status Indication

Short-Circuit Interrupting (SCI) Technology

1. Original State

2. Disconnection Device 

Response

3. Arc Extinguishes

4. Safe Electrical Isolation

1

2

3

4

Module Circuit Diagrams

Dimensions - mm

BSPH2600PV*

Shown with optional remote contact signaling

Shown with optional remote contact signaling

Data Sheet: 2145

Fuse Open

Thermal Disconnector

MOV

Fuse Closed

Arc

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPH2600PVR

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

478

Overvoltage Devices

Photovoltaic DIN-Rail SPD

Data Sheet: 2145

Ordering Information

Nominal PV System Voltage

600Vdc

Catalog Numbers:

Without Remote Signaling

BSPH2600PV

(Base + Modules)

With Remote Signaling

BSPH2600PVR

Replacement Modules:

Left

BPH300YPV

Right

BPM300YPV

Specifications

Conformity with prEN 50539-11

Yes

SPD Classification per EN 61643-11

Type 2

SPD Classification per IEC 61643-1

Class II

Max. PV voltage [U

CPV

]

_

< 600V

Short-circuit withstand capacity [I

SCWPV

]

1000A

MCOV [U

CPV

]

700Vdc

Nominal discharge current (8/20 μs) [(DC+/DC-) --> PE] [I

n

]

12.5kA

Max. Discharge current (8/20 μs) [(DC+/DC-) --> PE] [I

max

]

25kA

Voltage protection level [U

P

]

_

< 2.5kV

Voltage protection level at 5kA [U

P

]

_

< 2kV

Response time [t

A

]

_

< 25 ns

Operating temperature range [T

U

]

-40°C to +80°C

Operating state/fault indication

Green (good) / Red (replace)

Number of ports

1

Cross-sectional area (min.)

60/75°C 1.5mm

2

/14AWG Solid/Flexible

Cross-sectional area (max.)

60/75°C 35mm

2

/2AWG Stranded/25mm

2

/4AWG Flexible

For mounting on

35 mm DIN rail per EN 60715

Enclosure material

Thermoplastic, UL 94V0

Place of installation

Indoor

Degree of protection

IP20

Capacity

2 Modules, DIN 43880

Standards Information

UL

Product Warranty

Five Years*

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.1A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals

60/75°C Max. 1.5mm

2

/14AWG Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

Typical Application Schematic

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

479

Surge Protection

Devices

Overvoltage Devices

Photovoltaic DIN-Rail SPD

BSPH_ _ _ _YPV

Description

The Bussmann three-module photovoltaic Surge Protective
Device (SPD) (with three-step DC switching device) features

easy

ID™ visual indication and optional remote contact 

signaling (floating changeover contact) for use in PV 
systems.

These complete surge protective devices are suitable for all 
PV systems in accordance with UL 1449 3

rd

Edition and 

IEC 60364-7-712. Includes a five year limited warranty.

These prewired solutions consist of a base and locking 
modules that feature a combined disconnection and 
short-circuiting (shunting) device with safe electrical isolation
to prevent fire damage due to DC arcs. An integrated DC fuse
allows safe module replacement without arc formation.

In case of insulation faults in the generator circuit, a reliable
and tested fault-resistant Y circuit prevents damage to the
surge protective devices.

The green and red visual indicator flags show the module
protective status (green = good, red = replace). Apart from
this visual indication, the remote signaling option features a
three terminal floating changeover contact that can be used
as a make or break contact depending on the particular 
monitoring system design employed.

Remote Signal 

Contact Available

Visual Status Indication

Module Circuit Diagrams

Dimensions - mm

BSPH_____YPV*

Shown with optional remote contact signaling

Shown with optional remote contact signaling

Short-Circuit Interrupting (SCI) Technology

1. Original State

2. Disconnection Device 

Response

3. Arc Extinguishes

4. Safe Electrical Isolation

1

2

3

4

Data Sheet: 2055

12

11

14

DC+/–

DC–/+

Fuse Open

Thermal Disconnector

MOV

Fuse Closed

Arc

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPH____YPVR

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

480

Overvoltage Devices

Photovoltaic DIN-Rail SPD

Data Sheet: 2055

Ordering Information

Nominal PV System Voltage

600Vdc

1000Vdc

1200Vdc

Catalog Numbers:

Without Remote Contact Signaling

BSPH3600YPV

BSPH31000YPV

BSPH31200YPV

(Base + Modules)

With Remote Contact Signaling

BSPH3600YPVR

BSPH31000YPVR

BSPH31200YPVR

Replacement Modules:

Outer (2 modules installed)

BPH300YPV

BPH500YPV

BPH600YPV

Center (1 module installed)

BPM300YPV

BPM500YPV

BPM600YPV

Specifications

Nominal PV System Voltage

600V

1000V

1200V

MCOV [U

CPV

]

700Vdc

1170Vdc

1200Vdc

Max System Discharge Current (8/20 μs) [I

max

]

40kA

40kA

30kA

Voltage Protection Level [U

P

]

<

_2.5kV

<

_4.0kV

<

_4.5kV

Voltage Protection Level at 5kA [U

P

]

<

_2.0kV

<

_3.5kV

<

_4.0kV

Integrated Fuse Breaking Capacity/Interrupting Rating

30kA / 1000Vdc

30kA / 1000Vdc

30kA / 1200Vdc

Technology

Short-Circuit Interruption (SCI) Overcurrent Protection

Operating Temperature Range [T

U

]

-40°C to +80°C

Nominal Discharge Current (8/20 μs) [(DC+/DC-) --> PE] [I

n

]

12.5kA

Response Time [t

A

]

<

_25ns

Operating State/Fault Indication

Green (good) / Red (replace)

Conductor Ratings and Cross-Sectional Area: Minimum

60/75°C 1.5mm

/ 14AWG Solid/Flexible

Maximum

60/75°C 35mm

/ 2AWG Stranded / 25mm

/ 4AWG Flexible

Mounting

35mm DIN Rail per EN 60715

Enclosure Material

UL 94V0 Thermoplastic

Degree of Protection

IP20

Capacity

3 Modules, DIN 43880

Standards Information:

UL

UL 1449 3

rd

Edition (Type 2)*

IEC

IEC 61643-11 Type 2, IEC 61643-1 Class II

Product Warranty

Five Years**

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V / 0.1A

DC Switching Capacity (Volts/Amps)

250V / 0.1A; 125V / 0.2A; 75V / 0.5A

Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals

60/75°C Max. 1.5mm

/ 14AWG Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* Does not apply to 1200Vdc.

** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Typical Application Schematics

 Equipment

Grounding

Conductor

Common

 Equipment

Grounding

Conductor

Common

 Equipment

Grounding

Conductor

Common

Application A

Two energized poles/modes

600, 1000 & 1200Vdc systems

Application B

One energized pole/mode

600Vdc & 1000Vdc systems only

Application C

One energized pole/mode

600Vdc & 1000Vdc systems only

(

Max. system discharge current 

(8/20 μs) [Imax] 25kA)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

481

Surge Protection

Devices

Photovoltaic DIN-Rail SPD

15.3

11.0

30.0

54.0

43.5

58.0

7.0

9.0

90.0

45.0

(3TE)

Description

The Bussmann three-module photovoltaic Surge Protective

Device (SPD) features 

easy

ID™ visual indication and optional

remote contact signaling (floating changeover contact) for use

in PV systems.

These complete surge protective devices are suitable for all

PV systems in accordance with UL 1449 3

rd

Edition, 

EN 50539-11 and IEC 60364-7-712. Includes a two year 

limited warranty.

These prewired solutions consist of a base and modules that

feature a disconnection device in the event of an overload.

In case of insulation faults in the generator circuit, a reliable

and tested fault-resistant Y circuit prevents damage to the

surge protective devices.

The green and red visual indicator flags show the module 

protective status (green = good, red = replace). Apart from

this visual indication, the remote signaling option features a

three terminal floating changeover contact that can be used

as a make or break contact depending on the particular 

monitoring system design employed.

Module Circuit Diagrams

12

11

14

DC+/–

DC–/+

BSPP_____YPV*

Shown with optional remote contact signaling

* For remote signaling contact, add “R” suffix to the part number.

E.g., BSPP3600YPV

R

Shown with optional

remote contact signaling

Remote Signal 

Contact

Available

Visual Status

Indication

Thermal Disconnector

MOV

Overvoltage Devices

Dimensions - mm

BSPP

_____

YPV(R)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

482

Overvoltage Devices

Wind IEC Class I DIN-Rail SPD

Ordering Information

Nominal PV System Voltage

600Vdc

1000Vdc

Catalog Numbers:

Without Remote Contact Signaling

BSPP3600YPV

BSPP31000YPV

(Base + Modules)

With Remote Contact Signaling

BSPP3600YPVR

BSPP31000YPVR

Replacement Modules:

BPP300SYPV

BPP500SYPV

Specifications

Nominal PV System Voltage [U

CPV

]

600V

1000V

MCOV [U

CPV

]

600Vdc

1000Vdc

Max System Discharge Current (8/20µs) [I

max

]

40kA

40kA

Voltage Protection Level [U

P

]

≤2.5kV

≤4.0kV

Voltage Protection Level at 5kA [U

P

]

≤2.0kV

≤3.5kV

Short-Circuit Withstand Capability [I

SCPV

]

125A

Technology

Fault Resistant Y MOV Circuit

Operating Temperature Range [T

U

]

-40°C to +80°C

Nominal Discharge Current (8/20µs) (DC+ 

DC-) (DC+/DC- 

PE) [I

n

]

20kA

Response Time [t

A

]

≤25ns

Operating State/Fault Indication

Green (good) / Red (replace)

Conductor Ratings and Cross-Sectional Area: Minimum

60/75°C 1.5mm

/ 14AWG Solid/Flexible

Maximum

60/75°C 35mm

/ 2AWG Stranded / 25mm

/ 4AWG Flexible

Mounting

35mm DIN-Rail per EN 60715

Enclosure Material

UL 94V0 Thermoplastic

Degree of Protection

IP20

Capacity

3 Modules, DIN 43880

Standards Information:

UL

UL 1449 3

rd

Edition (Type 2)

IEC

EN 50539-11, IEC 61643-11 Type 2, IEC 61643-1 Class II

Product Warranty

Two Years*

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V / 0.1A

DC Switching Capacity (Volts/Amps)

250V / 0.1A; 125V / 0.2A; 75V / 0.5A

Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals

60/75°C Max. 1.5mm

/ 14AWG Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

** BSPP31000YPV(R) 1000Vdc one energized pole/mode requires the following:

1. Use a suitable electrical insulator to keep a 10mm min. safety distance from the PV-SPD and other grounded parts in the housing.

2. No metal covers are in the area of the module release buttons as shown.

Typical Application Schematics

Application A

Two energized poles/modes

600 & 1000Vdc systems

Application B

One energized pole/mode

600Vdc & 1000Vdc systems only

Application C

One energized pole/mode

600Vdc & 1000Vdc** systems

Data Sheet: 10091

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

483

Surge Protection

Devices

Overvoltage Devices

Wind IEC Class I DIN-Rail SPD

BSPS_ _ _ _WE

Description

The Bussmann IEC Class I 400 and 690V, one-pole lightning
current arresters feature local, 

easy

ID™ visual indication and

optional remote contact signaling.

440V and 760V maximum continuous operating voltage
arresters protect installations against surges and direct 
lightning strikes.

System & Application

TNC 400V/690V: 3x BSPS1400WE(R)

TNS 400/690V: 4x BSPS1400WE(R)

IT 690V: 3x BSPS1690WER

Remote Signaling Contact

The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.

BSPS1400WE*

BSPS1690WE

Shown with optional remote contact signaling

Circuit Diagrams - 

Shown with optional remote contact 

signaling

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

Spark Gap Trigger

Creepage Discharge Spark Gap

Data Sheet: 2091

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPS1400WER

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

484

Overvoltage Devices

Wind IEC Class I DIN-Rail SPD

Ordering Information

System Voltage/Poles

400V/1

690V/1

Max. Continuous Operating AC voltage (MCOV) [U

C

]

440V

760V

Catalog Numbers:

Without Remote Signaling

BSPS1400WE

- -

With Remote Signaling

BSPS1400WER

BSPS1690WER

Specifications

Line System Type

TNC, TNS, IT

TNC, TNS, IT

Lightning impulse current (10/350 μs)  [I

imp

]

35kA

25kA

Specific Energy  [W/R]

306.25kJ/ohms

156.25kJ/ohms

Nominal Discharge Current (8/20 μs)  [I

n

]

35kA

25kA

Voltage Protection Level  [U

P

]

_

< 2.5kV

_

< 4kV

Follow Current Extinguishing Capability AC  [I

fi

] 50kA

rms

25kArms

Follow Current Limitation / Selectivity

no tripping of a 32 A gL/gG 

no tripping of a 32 A gL/gG 

fuse up to 50 kA

rms

(prosp.)

fuse up to 25 kA

rms

(prosp.)

Response Time  [t

A

]

_

< 100 ns

_

< 100 ns

Max. Backup Fuse (L) up to I

K

= 25kA

rms

(t

a

_

< 5 s)

- -

250A gL/gG

Max. Backup Fuse (L) up to I

K

> 25kA

rms

- -

100A gL/gG

Max. Backup Fuse (L) up to I

K

= 50kA

rms

(t

a

_

< 0.2 s)

500A gL/gG

- -

Max. Backup Fuse (L) up to I

K

= 50kA

rms

(t

a

_

< 5 s)

250A gL/gG

- -

Max. Backup Fuse (L) for I

K

> 50kA

rms

160A gL/gG

- -

Max. Backup Fuse (L-L )

125A gL/gG

125A gL/gG

Short-Circuit Withstand Capability for 
Max. Mains-Side Overcurrent Protection

50kA

rms

25kA

rms

Temporary Overvoltage (TOV)  [U

T

]

690V / 5 sec.

1000V / 5 sec.

Cross-Sectional Area (L, L , 

) [min.]

- -

10mm

2

solid/flexible

Cross-Sectional Area (L, L , N/PEN) [min.]

10mm

2

solid/flexible

- -

Cross-Sectional Area (L, N/PEN) [max.]

50mm

2

/1AWG stranded/35mm

2

/2AWG flexible

- -

Cross-Sectional Area (L, 

) [max.]

- -

50mm

2

/1AWG stranded/35 mm

2

/2AWG flexible

Cross-Sectional Area (L ) [max.]

35mm

2

/2AWG stranded/25mm

2

/4AWG flexible

35mm

2

/2AWG stranded/25mm

2

/4AWG flexible 

SPD According to EN 61643-11

Type 1

SPD According to IEC 61643-1

Class I

TOV Characteristics

Withstand

Operating Temperature Range (parallel connection)  [T

UP

]

-40°C to +80°C

Operating Temperature Range (series connection)  [T

US

]

-40°C to +60°C

Operating State/Fault Indication

Green (good) / Red (replace)

Number of Ports

1

Mounting

35mm DIN rail per EN 60715

Enclosure Material

Thermoplastic, UL 94V0

Place of Installation

Indoor

Degree of Protection

IP20

Capacity

2 Mods., DIN 43880

Product Warranty

Five Years*

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.5A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for Remote 

60/75°C Max. 1.5mm

2

/

Contact Signal Terminals

14AWG  Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at 

www.cooperbussmann.com/surge.

Recommended Bussmann NH DIN Size Back Up Fuses

Size

NH Fuse Part Number

000

100NHG000B-690 (max 

L) up to I

K

> 25kA

rms

00

125NHG00B-690 (max 

L-L )

01

160NHG01B-690 (max 

L) for I

K

> 50kA

rms

02

250NHG02B-690 (max 

L) up to I

K

= 25kA

rms

(t

a

_

< 5 s)

02

250NHG02B-690 (max 

L) up to I

K

= 50kA

rms

(t

a

_

< 5 s)

3

500NHG3B-690 (max 

(L) up to I

K

= 50kA

rms

(t

a

_

< 0.2 s)

Data Sheet: 2091

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

485

Surge Protection

Devices

Overvoltage Devices

Wind IEC Class II DIN-Rail SPD

BSPM_ _ _ _WE, BSPS_ _ _ _WE

Description

The Bussmann IEC Class II 75, 230, 400, 690 and 1000V, one-pole,
modular surge arresters feature local, 

easy

ID™ visual indication and

optional remote contact signaling. The unique module locking system
on the 75 to 690V arresters fixes the protection module to the base
part. Modules can be easily replaced without tools by simply
depressing the release buttons. Integrated mechanical coding
between the base and protection module ensures against installing
an incorrect replacement module.

TN System Arresters (also 1-Phase TT systems)

The features of these single-pole devices are for use as a single
device or in combination with other devices.

TT System Arrester

Provides a current arresting means between neutral conductor and
protective conductor in TT systems, this device helps ensure fulfilling
the requirements for protection of personnel and equipment in “3+1”
and “1+1” circuits.

Remote Signaling Contact

The three-pole terminal remote signaling contact versions have a
floating changeover contact for use as a break or make contact,
according to circuit concept.

BSPM175WE*

BSPM1400WE
BSPM1690WE

BSPM11000WE*

BSPG1230WE*

Module Circuit Diagrams - 

Shown with optional remote 

contact signaling

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

MOV

Thermal Disconnector

Gas Discharge Tube (single)

Shown with 

optional remote 

contact signaling

75 to 690V

Arresters

1000V Arrester

Data Sheet: 2092

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPM175WER

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

486

Overvoltage Devices

Wind IEC Class II DIN-Rail SPD

Ordering Information

System Voltage/Poles

75V/1

230V/1

400V/1

690V/1

1000V/1

Max. Continuous operating AC voltage (MCOV) [U

C

]

75V

255V

440V

600V

1000V

Catalog Numbers:

Without Remote Signaling

BSPM175WE

BSPG1230WE

BSPM1400WE

BSPM1690WE

BSPM11000WE

(Base + Modules)

With Remote Signaling

BSPM175WER

BSPG1230WER

BSPM1400WER

BSPM1690WER

BSPM11000WER

Replacement Modules

BPM75WE

BPG255NPEWE*

BPM440WE

BPM750WE

N/A

Specifications

Line System Type

TN / TT

TT

TN / TT

TN / TT

TN / TT

Max. Continuous Operating DC Voltage  [U

C

]

100V

- -

585

600V

1000V

Rated Varistor Voltage AC [U

mov

]

- -

- -

- -

750V

1000V

Nominal Discharge Current (8/20 μs)  [I

n

]

10kA

20kA

20kA

15kA

15kA

Max. Discharge Current (8/20 μs)  [I

max

]

40kA

40kA

40kA

25kA

30kA

Follow Current Extinguishing Capability  [I

fi

]

- -

100 A

rms

- -

- -

- -

Lightning Impulse Current (10/350 μs)  [I

imp

]

- -

12kA

- -

- -

- -

Voltage Protection Level  [U

P

]

_

< 0.4kV

_

< 1.5kV

_

< 2.0kV

_

< 3kV

_

< 4.2kV

Voltage Protection Level at 5kA  [U

P

]

_

< 0.35kV

- -

_

< 1.7kV

_

< 2.5kV

_

< 3.5kV

Response Time  [t

A

]

_

< 25 ns

_

< 100 ns

_

< 25 ns

_

< 25 ns

_

< 25 ns

Max. Mains-side Overcurrent Protection

125A gL/gG

- -

125A gL/gG

100A gL/gG

100A aM**

Short-Circuit Withstand Capability for 

50kA

rms

- -

25kA

rms

25kA

rms

25kA

rms

Max. Mains-side Overcurrent Protection
Temporary Overvoltage (TOV)  [U

T

]

90V / 5 sec.

1200V / 200ms

580V / 5 sec.

900V / 5 sec.

1000V / 5 sec.

Standards Information

KEMA, CSA

KEMA

KEMA, CSA

KEMA, CSA

- -

Capacity

1 Mod., DIN 43880 1 Mod., DIN 43880

1 Mod., DIN 43880 1 Mod., DIN 43880

2 Mod., DIN 43880

SPD According to EN 61643-11

Type 2

SPD According to IEC 61643-1

Class II

TOV Characteristics

Withstand

Operating Temperature Range  [T

U

]

-40°C to +80°C

Operating State/Fault Indication

Green (good) / Red (replace)

Number of Ports

1

Cross-Sectional Area (min.)

1.5mm

2

/14AWG solid/flexible

Cross-Sectional Area (max.)

35mm

2

/2AWG stranded-25mm

2

/4AWG flexible

Mounting

35mm DIN rail per EN 60715

Enclosure Material

Thermoplastic, UL 94V0

Location Category

Indoor

Degree of Protection

IP20

Product Warranty

Five Years***

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.5A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for

60/75°C Max. 1.5mm

2

/14AWG Solid/Flexible

Remote Contact Signal Terminals
Ordering Information

Order from Catalog Numbers Above

*

N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.

** 125A gL/gG @ 690Vac.
*** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Recommended Bussmann Back Up Fuses

DIN Fuse Size

NH Fuse Part Number

00

100NHG00B-690

00

125NHG00B-690

Data Sheet: 2092

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

487

Surge Protection

Devices

Overvoltage Devices

Wind IEC Class II DIN-Rail SPD

BSPM_ _ _ _WE, BSPH_ _ _ _WE

Description

The Bussmann IEC Class II 230V, two-pole, modular surge
arresters feature local, 

easy

ID™ visual indication and 

optional remote contact signaling. The unique module locking
system fixes the protection module to the base part. Modules
can be easily replaced without tools by simply depressing the
release buttons. Integrated mechanical coding between the
base and protection module ensures against installing an
incorrect replacement module.

TN System Arrester

The features of these two-pole device are for use as a single
device.

TT System Arrester

For use as a single device in a 1-phase TT system.

Remote Signaling Contact

The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.

BSPM2230WE*

BSPH2230WE*

Shown with optional remote contact signaling

Module Circuit Diagrams - 

Shown with optional remote

contact signaling

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

MOV

Thermal Disconnector

Gas Discharge Tube (single)

Data Sheet: 2093

*For remote signaling contact, add “R” suffix to the part number,
E.g., BSPM2230WER

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

488

Overvoltage Devices

Wind IEC Class II DIN-Rail SPD

Ordering Information

System Voltage/Poles

230V/2

230V/2

Max. Continuous operating AC voltage (MCOV) [U

C

]

275V

275 / 255V

Catalog Numbers:

Without Remote Signaling

BSPM2230WE

BSPH2230WE

(Base + Modules)

With Remote Signaling

BSPM2230WER

BSPH2230WER

Replacement Modules

MOV

BPM275WE

BPM275WE

Spark Gap

- -

BPSNPEWE*

Specifications

Line System Type

TN

TT

Max. Continuous Operating AC Voltage [L-N]  [U

C

]

- -

275V

Max. Continuous Operating AC Voltage [N-PE]  [U

C

]

- -

255V

Nominal Discharge Current (8/20 μs)[I

n

]

20kA

20kA

Max. Discharge Current (8/20 μs)[I

max

]

40kA

40kA

Lightning Impulse Current (10/350 μs) [N-PE]  [I

imp

]

- -

12kA

Voltage Protection Level  [U

P

]

_

< 1.25kV

- -

Voltage Protection Level at 5kA  [U

P

]

_

< 1kV

- -

Voltage Protection Level [L-N]  [U

P

]

-  -

_

< 1.25kV

Voltage Protection Level [L-N] at 5kA  [U

P

]

-  -

_

< 1kV

Voltage Protection Level [N-PE]  [U

P

]

-  -

_

< 1.5kV

Follow Current Extinguishing Capability [N-PE]  [I

fi

]

- -

100A

rms

Response Time [L-N]  [t

A

]

-  -

_

< 25 ns

Response Time [N-PE]  [t

A

]

-  -

_

< 100 ns

Response Time [t

A

]

_

< 25 ns

- -

Max. Mains-side Overcurrent Protection 

125A gL/gG

125A gL/gG

Short-circuit Withstand Capability for Max. Mains-side Overcurrent Protection

50kA

rms

50kA

rms

Temporary Overvoltage (TOV)  [U

T

]

335 V / 5 sec.

- -

Temporary Overvoltage (TOV) [L-N]  [U

T

]

- -

335V / 5 sec.

Temporary Overvoltage (TOV) [N-PE]  [U

T

]

- -

1200V / 200 ms

SPD According to EN 61643-11

Type 2

SPD According to IEC 61643-1

Class II

TOV Characteristics

Withstand

Operating Temperature Rrange  [T

U

]

-40°C to +80°C

Operating State/Fault Indication

Green (good) / Red (replace)

Number of Ports

1

Cross-sectional Area (min.)

1.5mm

2

/14AWG solid/flexible

Cross-sectional Area (max.)

35mm

2

/2AWG stranded-25mm

2

/4AWG flexible

Mounting

35mm DIN rail per EN 60715

Enclosure Material

Thermoplastic, UL 94V0

Location Category

Indoor

Degree of Protection

IP20

Capacity

2 Mods., DIN 43880

Standards Information

KEMA

Product Warranty

Five Years**

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.5A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for

60/75°C Max. 1.5mm

2

/

Remote Contact Signal Terminals

14AWG Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.

** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Recommended Bussmann Back Up Fuse

DIN Fuse Size

NH Fuse Part Number

00

125NHG00B

Data Sheet: 2093

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

489

Surge Protection

Devices

Overvoltage Devices

Wind IEC Class II DIN-Rail SPD

BSPM_ _ _ _WE

Specifications
Description

The Bussmann IEC Class II 230, 400 and 690V three-pole,
modular surge arresters feature local, 

easy

ID™ visual 

indication and optional remote contact signaling. The unique
module locking system fixes the protection module to the
base part. Modules can be easily replaced without tools by
simply depressing the release buttons. Integrated mechanical
coding between the base and protection module ensures
against installing an incorrect replacement module.

TNC System Arresters

The features of these three-pole devices are for use as a 
single device.

Remote Signaling Contact

The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.

BSPM3230WE
BSPM3400WE
BSPM3690WE

Shown with optional remote contact signaling

Module Circuit Diagrams - 

Shown with optional remote

contact signaling

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

MOV

Thermal Disconnector

Data Sheet: 2094

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

490

Overvoltage Devices

Wind IEC Class II DIN-Rail SPD

Ordering Information

System Voltage/Poles

230V/3

400V/3

690V/3

Max. Continuous operating AC voltage (MCOV) [U

C

]

275V

440V

600V

Catalog Numbers:

Without Remote Signaling

BSPM3230WE

BSPM3400WE

BSPM3690WE

(Base + Modules)

With Remote Signaling

BSPM3230WER

BSPM3400WER

BSPM3690WER

Replacement Modules

BPM275WE

BPM440WE

BPM750WE

Specifications

Line System Type

TNC

TNC

TNC

Nominal AC Voltage  [U

N

]

230/400V

400/690V

600V

Rated Varistor Voltage  [U

mov

]

275V

440V

750V

Nominal Discharge Current (8/20 μs)  [I

n

]

20kA

20kA

15kA

Max. Discharge Current (8/20 μs)  [I

max

]

40kA

40kA

25kA

Voltage Protection Level  [U

P

]

_

<1.25kV

_

< 2kV

_

<3kV

Voltage Protection Level at 5kA  [U

P

]

_

<1kV

_

< 1.7kV

_

<2.5kV

Response Time  [t

A

]

_

<25 ns

_

< 25 ns

_

<25 ns

Max. Mains-side Overcurrent Protection

125A gL/gG

125A gL/gG

100A gL/gG

Short-circuit Withstand Capability for Max. Mains-side Overcurrent Protection

50kA

rms

25kA

rms

25kA

rms

Temporary Overvoltage (TOV)  [U

T

]

335V / 5 sec.

580V / 5 sec.

900V / 5 sec.

SPD According to EN 61643-11

Type 2

SPD According to IEC 61643-1

Class II

TOV Characteristics 

Withstand

Operating Temperature Range  [T

U

]

-40°C to +80°C

Operating State/Fault Indication

Green (good) / Red (replace)

Number of Ports

1

Cross-Sectional Area (min.)

1.5mm

2

/14AWG solid/flexible

Cross-Sectional Area (max.)

35mm

2

/2AWG stranded-25mm

2

/4AWG flexible

Mounting

35mm DIN rail per EN 60715

Enclosure Material

Thermoplastic, UL 94V0

Location Category

Indoor

Degree of Protection

IP20

Capacity

3 Mods., DIN 43880

Standards Information

KEMA

Product Warranty

Five Years*

Remote Contact Signaling

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.5A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for

60/75°C Max. 1.5mm

2

/14AWG  Solid/Flexible

Remote Contact Signal Terminals
Ordering Information

Order from Catalog Numbers Above

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Recommended Bussmann Back Up Fuse

DIN Fuse Size

NH Fuse Part Number

00

100NHG00B-690
125NHG00B-690

Data Sheet: 2094

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

491

Surge Protection

Devices

Overvoltage Devices

Wind IEC Class II DIN-Rail SPD

BSPM_ _ _ _WE, BSPH_ _ _ _WE

BSPH4230WE

Shown with optional remote contact signaling

Circuit Diagrams - 

Shown with  optional remote contact 

signaling

Dimensions - mm

Remote Signal 

Contact Available

Visual Status Indication

Specifications
Description

The Bussmann IEC Class II 230/400V, four-pole, modular
surge arresters feature local, 

easy

ID™ visual indication and

optional remote contact signaling. The unique module locking
system fixes the protection module to the base part. Modules
can be easily replaced without tools by simply depressing the
release buttons. Integrated mechanical coding between the
base and protection module ensures against installing an
incorrect replacement module.

These 230V models are offered with MCOV ratings of 275V.

TNS System Arrester

The features of these four-pole devices are for use in TNS
230/400V systems (“4-0” circuit) against surges.

TT System Arrester

The features of these four-pole devices are for use in TT and
TN-S 230/400V systems (“3+1” circuit) against surges.

Remote Signaling Contact

The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.

MOV

Thermal Disconnector

Gas Discharge Tube 

(single)

Data Sheet: 2095

BSPM4230WE

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

492

Overvoltage Devices

Wind IEC Class II DIN-Rail SPD

O

RDERING

I

NFORMATION

System Voltage/Poles

230/400V/4

230/400V/4

Max. continuous operating AC voltage (MCOV) [U

C

]

275V

- -

Max. continuous operating AC voltage (MCOV) [L-N] [U

C

]

- -

275V

Max. continuous operating AC voltage [N-PE] [U

C

]

- -

255V

Catalog Numbers:

Without Remote Signaling

BSPM4230WE

BSPH4230WE

With Remote Signaling

BSPM4230WER

BSPH4230WER

Replacement Modules:

MOV technology

BPM275WE

BPM275WE

Spark Gap technology

- -

BPSNPEWE*

S

PECIFICATIONS

Line System Type

TNS

TT / TNS

Nominal AC voltage [U

N

]

230/400V

230/400V

Lightning impulse current (10/350 μs) [N-PE] [I

imp

]

- -

12kA

Voltage protection level [U

P

]

<

_ 1.25kV

- -

Voltage protection level at 5kA [U

P

]

<

_ 1kV

- -

Voltage protection level [L-N] [U

P

]

-  -

<

_ 1.25kV

Voltage protection level [L-N] at 5kA [U

P

]

-  -

<

_ 1kV

Voltage protection level [N-PE] [U

P

]

-  -

<

_ 1.5kV

Follow current extinguishing capability [N-PE] [I

fi

]

-  -

100A

rms

Response time [t

A

]

<

_ 25 ns

- -

Response time [L-N] [t

A

]

-  -

<

_ 25 ns

Response time [N-PE] [t

A

]

-  -

<

_ 100 ns

Temporary overvoltage (TOV) [U

T

]

335V / 5 sec.

- -

Temporary overvoltage (TOV) [L-N] [U

T

]

- -

335V / 5 sec.

Temporary overvoltage (TOV) [N-PE] [U

T

]

- -

1200V / 200 ms

SPD according to EN 61643-11

Type 2

SPD according to IEC 61643-1

Class II

Nominal discharge current (8/20 μs) [I

n

]

20kA

Max. discharge current (8/20 μs) [I

max

]

40kA

Max. mains-side overcurrent protection

125A gL/gG

Short-circuit withstand capability for max. mains-side overcurrent protection

50kA rms

TOV characteristics

withstand

Operating temperature range [T

U

]

-40°C to +80°C

Operating state/fault indication

green (good)/red (replace)

Number of ports

1

Cross-sectional area (min.)

1.5mm

2

/14AWG solid/flexible

Cross-sectional area (max.)

35mm

2

/2AWG stranded-25mm

2

/4AWG flexible

Mounting

35mm DIN rail per EN 60715

Enclosure material

Thermoplastic, UL 94V0

Location category

Indoor

Degree of protection

IP20

Capacity

4 Mods., DIN 43880

Standards Information

KEMA

Product Warranty

Five Years**

R

EMOTE

C

ONTACT

S

IGNALING

Remote Contact Signaling Type

Changeover Contact

AC Switching Capacity (Volts/Amps)

250V/0.1A

DC Switching Capacity (Volts/Amps)

250V/0.1A; 125V/0.2A; 75V/0.5A

Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals

60/75°C Max. 1.5mm

2

/14AWG  Solid/Flexible

Ordering Information

Order from Catalog Numbers Above

* N-PE Surge arrester module for location between neutral conductor and protective conductor in TT systems.

** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Recommended Bussmann Back Up Fuse

DIN Fuse Size

NH Fuse Part Number

00

125NHG00B

Data Sheet: 2095

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

493

Surge Protection

Devices

Surge Protection Made Simple™ for Coaxial Data Cables

UL Listed 497B DIN-Rail Mount Surge Protective Device for BNC Connector Cable
Systems

BSPD5BNCDD

BSPD5BNCDI

Protected
side

Protected
side

 100.08 

 19.00 

 35.50 

 12.70 

Circuit Diagrams

DIN-Rail Mount SPD 

for BNC Coax

Description

The Bussmann BSPD5BNCDD and BSPD5BNCDI two-stage

DIN-Rail mounted surge arresters are for protecting coaxial

cable-connected systems (such as video and camera 

systems) from potential damage. The BSPD5BNCDD features

direct (VCD) shield connection while the BSPD5BNCDI 

features indirect shield connection (VCID) to prevent leakage

pickups.

The BSPD5BNCDD and BSPD5BNCDI shielded surge

arresters are mounted on the supplied bracket with cable lug

or mounted on a rack mounted DIN-Rail with suitable 

grounding. BNC connector terminated data or video signal

cables are plugged into surge arrester with the equipment

plugged into the protected side.

Common applications include protecting outdoor video 

surveillance systems or video control centers or coaxial data

lines. For BSPD5BNCDI, the cable shield is indirectly 

grounded via a gas discharge tube to avoid being influenced

by leakage pickups.

• UL 497

B

 Listed

• Plug-in surge protective device for easy retrofitting

• The space-saving surge arrester with 

B

NC socket is mounted

on supplied rail terminal lug or standard 35mm DIN-Rail

• Integrated direct or indirect shield grounding avoids leakage

pickups

• Easily adaptable due to 

B

NC sockets

Dimensions-mm

Direct Shield

BSPD5BNCDD

Indirect Shield

BSPD5BNCDI

Gas Discharge Tube

B

i-Polar Suppressor Diode

Pluggable Earthing Contact

Decoupling Resistor

Overvoltage Devices

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

494

Overvoltage Devices

Technical Data

Catalog Number

B

SPD5

B

NCDD

B

SPD5

B

NCDI

Return loss at 300MHz

≥8d

B

≥10d

B

Capacitance shield-PG (C)

≤20pF

Voltage protection level shield-PG for In C2 (U

p

)

≤650V

Voltage protection level shield-PG at 1kV/μs C3 (U

p

)

≤600V

Nominal voltage (U

N

)

5V

Max. continuous operating DC voltage (U

C

)

6.4V

Nominal current (I

L

)

0.1A

C2 Nominal discharge current (8/20μs) shield-PG (I

n

)

10kA

C2 Nominal discharge current (8/20μs) line-shield (I

n

)

5kA

Voltage protection level line-shield for I

n

C2 (U

p

)

≤35V

Voltage protection level line-shield at 1kV/μs C3 (U

p

)

≤13V

Frequency range

0-300MHz

Insertion loss at 160MHz

≤0.4d

B

Insertion loss at 300MHz

≤3d

B

Return loss at 130MHz

≥20d

B

Impedance (Z)

50Ω

Series impedance per line

4.7Ω

Capacitance line-shield (C)

≤25pF

Operating temperature range

-40°C to +80°C

Degree of protection

IP10

For mounting on

35mm DIN-Rails per EN 60715

Connection (input / output)

B

NC Socket (female) / 

B

NC Socket (female)

Grounding

Via 35mm DIN-Rail per EN 60715

Enclosure material

Zinc die casting

Color

B

are surface

Test standards

IEC 61643-21 / EN 61643-21

Agency Information

UL 497

B

Warranty

5 Years*

Part Numbers

BSPD5BNCDD

BSPD5BNCDI

Bus Systems and Measuring, and Control Technology

Control Net

X

X

Melsec Net 2

X

X

N1 LAN

X

X

Data Networks

Arcnet

X

X

Video Systems

Video (coax)

X

X

DIN-Rail BNC SPD Applications

Direct vs. Indirect Shielding - Application Example

Apply the BSPD5BNCDD (direct shield) at the equipment 

location and apply the BSPD5BNCDI (indirect shield) near

exterior protected equipment. The indirect shield grounding at

the exterior device will help avoid picking up leakage currents

that can degrade signal quality while providing surge 

protection when needed. See illustration below for installation

locations.

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/Surge.

LPZ 0

B

LPZ 1

LPZ 2

coaxial

Video

system

IEC 62305-4

protective angle 

protected

side

BSPD5BNCDI

BSPD5BNCDD

protected

side

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

495

Surge Protection

Devices

Overvoltage Devices

Surge Protection Made Simple™ for Coaxial Data Cables

UL Listed 497B In-line Surge Protective Device for BNC Connector Cable Systems

BSPD5BNCSI

 74.00 

 300.00 APPROX 

24.00 

Circuit Diagram

In-line SPD for BNC Coax

Description

The Bussmann BSPD5BNCSI two-stage in-line surge arrester

is for protecting coaxial cable-connected systems (such as

video and camera systems) from potential damage.

The BSPD5BNCSI shielded surge arrester is plugged into

coaxial terminal equipment or connections. Common 

applications include protecting outdoor video surveillance 

systems or video control centers. The cable shield is indirectly

grounded via a gas discharge tube to avoid being influenced

by leakage pickups. The arrester input is used as a socket and

the protected output as a plug.

• UL 497

B

 Listed

• Plug-in surge protective device for easy retrofitting

• Directly plugs into terminal equipment with 

B

NC coaxial 

connections

• Integrated indirect shield grounding avoids leakage pickups

Dimensions-mm

Gas Discharge Tube

B

i-Polar Suppressor Diode

Decoupling Resistor

Capacitor

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

496

Overvoltage Devices

T

ECHNICAL

D

ATA

Catalog Number

B

SPD5

B

NCSI

Nominal voltage (U

N

)

5V

Max. continuous operating DC voltage (U

C

)

8V

C2 Nominal discharge current (8/20μs) per line (I

n

)

2.5kA

C2 Nominal discharge current (8/20μs) shield-PG (I

n

)

10kA

Voltage protection level line-shield for I

n

C2 (U

p

)

≤25V

Voltage protection level line-shield at 1kV/μs C3 (U

p

)

≤15V

Voltage protection level shield-PG at 1kV/μs C3 (U

p

)

≤600V

Insertion loss at 265MHz

≤3d

B

Return loss at 40MHz

≥20d

B

Impedance (Z)

75Ω

Series impedance per line

10Ω

Capacitance line-shield (C)

≤50pF

Operating temperature range

-40°C to +80°C

Connection (input / output)

B

NC Socket (female) / 

B

NC Plug (male)

Grounding

Via outgoing earth conductor 18AWG (0.75mm

2

)

Shield grounding

Indirectly via an integrated spark gap element

Test standards

IEC 61643-21 / EN 61643-21

Agency information

UL 497

B

Warranty

5 Years*

Part Number

BSPD5BNCSI

Bus Systems and Measuring & Control Technology

Control Net

X

Melsec Net 2

X

Data Networks

Arcnet

X

Video Systems

Video (coax)

X

In-line BNC SPD Applications

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/Surge.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

497

Surge Protection

Devices

BSPD48RJ45

 76.91 

 19.00 

 11.72 

 36.15 

Circuit Diagram

DIN-Rail Mount SPD 

for RJ45 / Ethernet Connection

Description

The Bussmann DIN-Rail mount BSPD48RJ45 Surge

Protective Device (SPD) for Ethernet cable systems with RJ

connectors is easy to install in new, or retrofitting into 

existing, installations.

The BSPD48RJ45 is installed between the patch panel and

the active component (a switch for example). The snap-in

mechanism of the supporting foot allows the SPD to be safely

grounded via the DIN-Rail. For single applications, the

BSPD48RJ45 comes with a supplied mounting bracket with

cable lug.

Fulfilling the requirements of Category 6, the BSPD48RJ45

can be universally used for all data services up to nominal

voltages of 48V. It is well suited for existing services such as

Gigabit Ethernet, ATM, ISDN, Voice over IP and Power over

Ethernet (PoE+ acc. to IEEE 802.3at up to 57V) and similar

applications in structured cabling systems according to Class

E up to 250MHz. Protection of all pairs by means of powerful

gas discharge tubes and one adapter filter matrix per pair.

• UL 497

B

 Listed

• Easy to install or retrofit for protection of all lines

• CAT 6 according to ISO/IEC 11801

• CAT 6 in the channel (Class E)

• Power over Ethernet (PoE+ according to IEEE 802.3at)

Dimensions -mm

B

alanced Gas 

Discharge Tube

B

ipolar Suppressor Diode

Inductor

Surge Protection Made Simple™ for Ethernet Data Cables

UL Listed 497B Universal DIN-Rail Mount Surge Protective Device for RJ45/Ethernet Cable
Systems

Pluggable Earthing Contact

Overvoltage Devices

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

498

Overvoltage Devices

T

ECHNICAL

D

ATA

Catalog Number

B

SPD48RJ45

Nominal voltage (U

N

)

48V

Max. continuous operating DC voltage (U

C

)

48V

Max. continuous operating AC voltage (U

C

)

34V

Max. continuous DC voltage pair-pair (PoE) (U

C

)

57V

Nominal current (I

L

)

1A

C2 Nominal discharge current (8/20μs) line-line (I

n

)

150A

C2 Nominal discharge current (8/20μs) line-PG (I

n

)

2.5kA

C2 Total nominal discharge current (8/20μs) line-PG (I

n

)

10kA

C2 nominal discharge current (8/20μs) pair-pair (PoE) (I

n

)

150A

Voltage protection level line-line for I

n

C2 (U

P

)

≤190V

Voltage protection level line-PG for I

n

C2 (U

P

)

≤600V

Voltage protection level line-line for I

n

C2 (PoE) (U

P

)

≤600V

Voltage protection level line-line at 1kV/μs C3 (U

P

)

≤180V

Voltage protection level line-PG at 1kV/μs C3 (U

P

)

≤500V

Voltage protection level pair-pair at 1kV/μs C3 (PoE) (U

P

)

≤600V

Insertion loss at 250MHz

≤3d

B

Capacitance line-line (C)

≤30pF

Capacitance line-PG (C)

≤25pF

Operating temperature range

-40°C to +80°C

Degree of protection

IP10

For mounting on

35mm DIN-Rails per EN 60715

Connection (input / output)

RJ45 socket / RJ45 socket

Pinning

1 / 2, 3 / 6, 4 / 5, 7 / 8

Grounding

Via 35mm DIN-Rails per EN 60715

Enclosure material

Zinc die casting

Color

B

are surface

Test standards

IEC 61643-21 / EN 61643-21

Agency information

UL 497

B

Warranty

5 Years*

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/Surge.

Part Number

BSPD48RJ45

Bus systems and Measuring, and Control Technology

Industrial Ethernet

X

Data Networks

ATM

X

Ethernet 10/100/1000

X

FDDI, CDDI

X

Industrial Ethernet

X

Power over Ethernet (PoE)

X

Token Ring

X

VG Any LAN

X

Video Systems

Video (2 wire)

X

DIN-Rail RJ45 SPDs Applications

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

499

Surge Protection

Devices

Overvoltage Devices

Surge Protection Made Simple™ for Twisted Pair Data Cables

UL Listed 497B DIN-Rail Mount Universal Surge Protective Device for
Measuring and Control Circuits, and Bus Systems

Four-Pole DIN-Rail Mount Universal

SPD for Data Signal Applications

Description

The Bussmann universal four-pole, DIN-Rail mounted surge

arresters provide effective protection with minimum space

requirements and are designed for stringent requirements on the

availability of measuring and control circuits, and bus systems.

To ensure safe operation, the arresters provide protection against

vibration and shock up to a 30-fold acceleration of gravity. The

function-optimized design of the devices allows quick and easy

removal of protection modules via “make-before-break” terminals

that assure continuity of data signals in the protected and 

unprotected state.

For IEC Applications

- Instruction for Surge Protective Device Use

In Zone 2 Explosive Atmospheres per ATEX.

1. When installed in potentially explosive atmospheres, the Data

Signal DIN Series shall be installed into an enclosure which

meets the requirements of a recognized type of protection, in

accordance with EN 60079-0.

2. The Data Signal DIN Series as transient suppressor. This

approval applies to the following equipment types:

B

SPD5DING

B

SPD12DING

B

SPD24DING

B

SPD48DING

B

SPD5DINLHF

B

SPD24DINLHF

Ambient and Temperature Class

• -40°C to +80°C, T4:

DEKRA 12ATEX0254 X: II 3 G Ex nA IIC T4 Gc

• Standards used for:

ATEX: EN60079-0: 2009, EN 60079-15: 2005

• UL 497

B

 Listed

• Function-optimized design for safe use and easy installation

• Four-pole and base mounts on grounded 35mm DIN-Rail

• Module removal without signal interruption via “make-before-

break” circuitry

• 0-180V 

B

SPD0180DINL automatically adjusts to system 

operating voltage and can protect data circuits of different 

voltages up to 100mA load current.

Dimensions-mm

Circuit Diagrams

1

2

3

4

3‘

4‘

Protected

1

2

Protected

3

4

BSPD5DING

BSPD12DING
BSPD24DING
BSPD48DING

BSPD0180DINL

BSPD5DINLHF

BSPD24DINLHF

1‘

i

i

i

i

2‘

3‘

4‘

1

2

3

4

U>U

N

U>U

N

Protected

B

ipolar Suppressor Diode

Decoupling Resistor

Transient 

B

locking Unit

i

Thyristor

Surge Detection

U>U

N

B

alanced Gas 

Discharge Tube

C

US

12.00

90.00

3.97

 16.09 

 71.99 

 35.51 

 49.99 

 6.70 

 45.00 

 50.49 

BSPD5DING

BSPD12DING

BSPD24DING

BSPD48DING

BSPD5DINLHF

BSPD24DINLHF

BSPD0180DINL

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

500

Overvoltage Devices

T

ECHNICAL

D

ATA

Catalog number — Prefix: 

B

SPD…

…5DING

…12DING

…24DING

…48DING …5DINLHF

…24DINLHF

…0180DINL

Nominal voltage (U

N

)

5V

12V

24V

48V

5V

24V

0-180V

Nominal current at 45°C (I

L

)

1.0A

0.75A

0.75A

0.75A

1.0A

1.0A

≤0.1A@80°C

VPL line-line for I

imp

D1 (Up)

≤29V

≤50V

≤102V

≤160V

≤25V

≤65V

≤ U

N

+ 53V

VPL line-PG for I

imp

D1 (Up)

≤27V

≤37V

≤66V

≤95V

≤550V

≤550V

-

VPL line-line at 1kV/μs C3 (Up)

≤18V

≤38V

≤90V

≤140V

≤11V

≤47V

see Note 1

VPL line-PG at 1kV/μs C3 (Up)

≤9V

≤19V

≤45V

≤70V

≤550V

≤550V

-

VPL line-line for In C2 (Up)

-

-

-

-

-

-

see Note 2

VPL line-PG for C2 / C3 / D1

-

-

-

-

-

-

≤ 550V

D1 Total lightning impulse current (10/350μs) (Iimp)

10kA

10kA

10kA

10kA

10kA

10kA

10kA

D1 Lightning impulse current (10/350μs) per line (Iimp)

2.5kA

2.5kA

2.5kA

2.5kA

2.5kA

2.5kA

2.5kA

C2 Total nominal discharge current (8/20μs) (I

n

)

20kA

20kA

20kA

20kA

20kA

20kA

20kA

C2 Nominal discharge current (8/20μs) per line (I

n

)

10kA

10kA

10kA

10kA

10kA

10kA

10kA

Series impedance per line

1.0Ω

1.8Ω

1.8Ω

1.8Ω

1.0Ω

1.0Ω

10Ω/7.5Ω typ

Frequency of the operating voltage (fU

N

)

-

-

-

-

-

-

0-400Hz

Max. continuous operating DC voltage (U

C

)

6V

15V

33V

54V

6V

33V

180V

Max. continuous operating AC voltage (U

C

)

4.2V

10.6V

23.3V

38.1V

4.2V

23.3V

127V

Permissible superimposed signal voltage (U

Signal

)

± 5V

"Nominal current at 80°C (I

L

)

100mA

(corresponds to max. short-circuit current)"
Cut-off frequency line-PG (f

G

)

1.0MHz

2.7MHz

6.8MHz

8.7MHz

100MHz

100MHz

-

Cut-off frequency line-line (U

Signal

, balanced 100Ω) (f

G

)

-

-

-

-

-

-

50MHz

Capacitance line-line (C)

≤2.7nF

≤1.0nF

≤0.5nF

≤0.35nF

≤25pF

≤25pF

≤80pF

Capacitance line-PG (C)

≤5.4nF

≤2.0nF

≤1.0nF

≤0.7nF

≤16pF

≤16pF

≤16pF

ATEX Approvals

Agency information

††

††

††

††

††

††

IEC 61643-21 Test category

D1, C2, C3

Operating temperature range

-40°C to +80°C

Degree of protection

IP20

For mounting on

35mm DIN-Rails per EN 60715

Grounding

Via base part

Color / enclosure material

Grey / Polyamide PA 6.6

Test standards

IEC 61643-21 / EN 61643-21, UL 497

B

Connection (input / output)

Screw terminal

Conductors                                                    Solid

12-28AWG (4-0.08mm

2

)

Flexible

14-28AWG (2.5-0.08mm

2

)

Terminal torque

3.5 Lb-In (0.4 N•m)

Warranty

5 Years*

0-180V SPD Application and Mode of Operation

The BSPD0180DINL surge protective device automatically

adjusts to the operating voltage (from 0 to 180 volts) of the

protected device.

When an overvoltage event occurs, the SPD voltage 

protection level adjusts itself based upon the output terminal

operating voltage of the base.

Diagram 1: Voltage Protection Level Up (V) (Line - Line)

20 V

40 V

60 V

100 V

140 V

180 V

50 V

100 V

150 V

200 V

0 V

U

N

25 V

75 V

125 V

175 V

max. [V]

U

N

 (Operating Voltage)

80 V

120 V

160 V

 U

p

C2 = U

p

 line-line for I

n

 (8/20 μs)

C3 = U

p

 line-line for 1kV/μs)

C2

C3

U

n

* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.

Note 1 - See Diagram 1 - VPL line-line graph line C3.

Note 2 - See Diagram 1 - VPL line-line graph line C2.

† DEKRA 12ATEX0254 X: II 3 G Ex nA IIC T4 Gc

†† ATEX, UL, CSA

‡ UL 497B

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

501

Surge Protection

Devices

Overvoltage Devices

Part Numbers

BSPD5DING

BSPD12DING

BSPD24DING

BSPD48DING

BSPD5DINLHF BSPD24DINLHF

BSPD0180DINL

B

US

S

YSTEMS AND

M

EASURING

AND

C

ONTROL

T

ECHNOLOGY

0-20 mA, 4-20 mA Signals

X

X (4-20mA only)

X

Binary Signals

X

X

X

X

CAN-Bus (data line only)

X

X

C-Bus (Honeywell)

X

X

Data Highway Plus

X

Device Net (data line only)

X

X

Dupline

X

E-Bus (Honeywell)

X

Fieldbus Foundation

X

X

FIPIO / FIPWAY

X

FSK

X

X

IEC-Bus (RS485)

X

X

Interbus INLINE (I/O)

X

Interbus INLINE, 

X

X

Long-distance bus
K Bus

X

LON - TP/XF 78

X

LUXMATE Bus

X

X

M Bus

X

MODBUS

X

X

MPI Bus

X

X

Procontic CS31 (RS232)

X

Procontic T200 (RS422)

X

X

PROFIBUS DP/FMS

X

X

PROFIBUS PA

X

X

PROFIBUS SIMATIC NET

X

X

PSM EG RS422 & RS485

X

X

Rackbus (RS485)

X

X

R Bus

X

X

RS 485

X

X

RS422, V11

X

X

SafetyBUS p

X

X

Securilan LON Bus

X

SIGMASYS 

X

SS97 SIN/X (RS 232)

X

SUCONET

X

X

Resistance Temp. Measuring
Ni1000, PT100, PT1000 Wire

X

NTC & PTC Thermistors
TTL

X

TTY 4–20mA

X

T

ELECOMMUNICATION

, T

ELEPHONY

a/b Wires

X

ADSL, ADSL 2+

X

ISDN S0, S2m/U2m, UKO/UPO

X

Modem M1

X

SDSL, SHDSL

X

X

Telephony Systems

X

(e.g., Siemens, HICOM, Alcatel)
T-DSL

X

Telecommunication Systems

X

(e.g., Siemens, HICOM, Alcatel)
VDSL

X

D

ATA

N

ETWORKS

V 24 (RS232 C)

X

DIN-Rail Universal 4 Wire Data Signal SPDs and Applications

Universal 4 wire data signal SPD products are specified by

communication technology. The table below contains the 

specific SPD product, by part number, and the applications to

which they are suited to be used.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

502

Overvoltage Devices

SurgePOD™ Series

Surge Protective Overvoltage Device Modules

Description

Bussmann SurgePOD surge 
protective overvoltage device
modules are board-mounted.
Upon an overvoltage condition,
their voltage clamping feature
becomes conductive, safely
shunting the surge to ground.

All SurgePOD devices are UL
1449 3

rd

Edition Recognized Type

1 SPD and contain an internal
element that safely disconnects
the device upon reaching an
overvoltage breakdown condition.

Remote contact signaling

is accomplished with an optional

Normally Open

microswitch that closes upon reaching an

overvoltage breakdown condition.

Local visual indication 

is accomplished with optional visual

indicating tabs that protrude through the device’s top upon
reaching an overvoltage breakdown condition.

The SurgePOD’s MOV substrate material may be damaged by
excessive shock or rough handling. To ensure integrity of 
finished device, do NOT install any SurgePOD devices that
are dropped or abused during assembly.

Suitability of SurgePOD devices for application to be 
determined by end user.

Catalog Number System:

SPOD

320

S

T

R

Series:

SPOD

MCOV:

150, 270, 320, 420, 510, 550

Lead Length:

S = Short - 6.87mm
L = Long - 16.76mm

Visual Indicator Tab:

T = Yes
Blank = None

Remote Contact Signaling: 

R = Yes (Normally Open)
Blank = None

Agency Information

UL 1449 3

rd

Edition Recognized Type 1 Surge Protective

Device; File E340782.

Electrical Specifications

Maximum Continuous Operating Voltage (MCOV)

150Vac to 550Vac

Short-Circuit Current Rating (SCCR)

200kA

Nominal Discharge Current (I

n

) 8/20ms

20kA

Max Discharge Current Rating (I

max

) 8/20ms

50kA

Remote Contact Signaling Microswitch

20mA@15Vdc

Pb

Data Sheet: 1170

SurgePOD

Voltage / Color Code

Specifications

150V

270V

320V

420V

510V

550V

I

n

20kA

20kA

20kA

20kA

20kA

20kA

I

max

50kA

50kA

50kA

50kA

50kA

50kA

SCCR

200kA

200kA

200kA

200kA

200kA

200kA

MCOV (V

rms

)

150V

270V

320V

420V

510V

550V

VPR

600V

900V

1200V

1500V

1500V

1500V

Nominal V

rms

*

120V

220V

277V

347V

480V

480V

* Nominal Vrms @ 50/60Hz.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

503

Surge Protection

Devices

SurgePOD™ Series

Data Sheet: 1170

Overvoltage Devices

1.687

[42.85]

2.930

 Ref

[74.43]

0.195±0.01

[4.95±0.25]

0.660

[16.76]

1.000±0.01

[25.40±0.25]

1.684 [42.77]

0.100 [2.54]

Long

Terminals

0.349 [8.87]

0.143

[3.63]

Short

Terminals

0.627±0.01

[15.92±0.25]

0.22±0.05

[5.58±1.27]

Productivity Through Protection™

Productivity Through Protection™

0.280
[7.11]

Front View

Side View

Top View

Front View

Leads for optional
remote contact signaling.

Indication tab
deployed.

0.627

±0.01

[15.92

±0.25

]

1.687

[42.85]

2x 0.037

[0.94]

A

1.375

[34.93]

0.407

[10.34]

0.126

[3.20]

2x 0.325

[8.26]

Front

Terminal Dimensions / Pad Layout - in [mm]

Dimensions - in [mm]

Tolerance is ± 0.005” [0.13mm] unless otherwise stated.

Terminal Information and Mounting

The SurgePOD surge protective overvoltage devices have nickel-plated copper
terminals for easy solder connection to printed circuit boards.

Recommended Pad Layout for Remote Contact Signaling - in [mm]

Packaging Information

• 200 units per master pack

0.195

[4.9]

2x ø 0.039

[0.99]

0.231

[5.87]

0.228

[5.79]

0.050

[1.27]

0.747

[18.97]

0.184
[4.67]

Local visual indication 
tabs exposed upon 
reaching an overvoltage
breakdown condition.

SurgePOD 
device under
normal 
operation.

Mechanical Specifications

All components are rated IP20 finger-safe in the installed state.

Environmental Specifications

Plastic Material: Polybutylene Terephthalate

Flammability Rating:

UL 94V0

Storage Temperature: -25°C to 85°C

Operating Temperature: -25°C to 85°C

Local Visual Indication Tabs (Optional)

Dimension A

MCOV Rating

Inches

mm

150

0.431

10.95

270, 320

0.479

12.17

420, 510, 550

0.526

13.36

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

504

DIN-Rail TVS Series

Overvoltage Devices

Data Sheet: 9006

Specifications
Description:

DIN-Rail mount voltage surge protection 

system for AC or DC voltage using diode or MOV technology.

Construction:

Suppressor:  

Case: 20% glass filled PES (Polyethersulfone)
Terminals: 110 Copper
Terminal Plating: Electroless tin

Holder:

Case: 15% glass filled PBT (Polybutylene 

Terephthalate)
Interface Clips: CDA 7025
Interface Clip Plating: Electroless tin

Contact Lubricant: Fluoroether grease
Box Lug: Copper
DIN-Rail Springs: Stainless steel

Ratings*:

Volts: — 12Vdc (2kA surge current)

— 24Vdc (2kA surge current)

— 48Vdc (2kA surge current)

— 120Vac (7kA-18kA surge current)

— 240Vac (7kA-18kA surge current)

* See Catalog Numbers table for all specifications pertaining to specific voltage ratings.

Agency Information:

UL Recognized (UL 1449) for AC

products, (UL 497B) for DC products, CSA Approved.

Catalog Numbers

Catalog

Voltage

SVR

Surge Current

Agency

Label

Numbers

Application

MCOV

Technology

500A, 8x20μs

Rating

Information

Color

TVS12DCD

12Vdc

14Vdc

SASD

36Vdc

2kA

UL 497B

Red

TVS24DCD

24Vdc

28Vdc

SASD

58Vdc

2kA

UL 497B

White

TVS48DCD

48Vdc

57Vdc

SASD

90Vdc

2kA

UL 497B

Black

TVS120ACD

120Vac

140Vac

SASD

330Vac

7kA

UL 1449

Blue

TVS120ACM

120Vac

140Vac

MOV

500Vac

18kA

UL 1449

Grey

TVS240ACD

240Vac

280Vac

SASD

600Vac

7kA

UL 1449

Blue

TVS240ACM

240Vac

280Vac

MOV

800Vac

18kA

UL 1449

Grey

Product Specifications:

1. All TVS devices have non-polarized electrical connections 

as shown.

2. Suppressor voltage characteristics per chart.
3. Suppressor to provide non-interrupted service.
4. Enclosure material is 94V0 flame and explosion resistant.
5. Product markings show manufacturer, part number and safety 

warnings as required.

6. Mechanical dimensions as noted.
7. Suppressor Status LED as shown.
8. AC units operate on either 50 or 60Hz.

OFF - Suppressor Non-Operational (power may be on)
GREEN - Suppressor Operational (power on)

Power Terminals

14AWG - 4AWG

Dual 10AWG

Dimensions -in 

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Accessories

Reduce Downtime
With Quick Access 
to the Right
Replacement Fuse

Section Contents                           Page

Fuse Service Kits

Supplemental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 506-507

Branch circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 506-507

Premium branch circuit . . . . . . . . . . . . . . . . . . . . . . 506-507

Large electronic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508

Small electronic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508

Electrical & electronic . . . . . . . . . . . . . . . . . . . . . . . . . . . 508

Clips clamps & rail adapters (DIN & American) . . . . . 509

Spare fuse holders, pullers, testers & cabinets

Telepower spare fuse holders . . . . . . . . . . . . . . . . . . . . 510

5TPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510

Fuse pullers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510

FT-2 & FT-3 fuse testers . . . . . . . . . . . . . . . . . . . . . . . . 510

SFC spare fuse cabinet . . . . . . . . . . . . . . . . . . . . . . . . . 510

Fuse reducers & dummy “neutrals” 

Class J fuses - LPJ, JKS . . . . . . . . . . . . . . . . . . . . . . . . 511

Class R fuses - FRN-R, LPN-RK, FRS-R

& LPS-RK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 511

Class H & K fuses - NON, REN, NOS & RES . . . . . . . . 511

Dummy fuse “neutrals” . . . . . . . . . . . . . . . . . . . . . . . . . . 511

505

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Fuse Service Kits

Glass Fuse Kit

Catalog Number: GSK-260
Kit Contents

(5) GMA-500mA

(5) MDL-6

(5) AGC-10

(5) GMA-1A

(5) MDL-7

(5) AGC-15

(5) GMA-2A

(5) MDL-8

(5) AGC-20

(5) GMA-3A

(5) MDL-10

(5) GMC-2A

(5) GMA-4A

(5) MDL-15

(5) GMC-5A

(5) GMA-5A

(5) MDL-20

(5) GMC-10A

(5) GMA-6A

(5) AGC-

1

4

(5) MDA-5

(5) GMA-10A

(5) AGC-

1

2

(5) MDA-10

(5) GMA-15A

(5) AGC-1

(5) MDA-12

(5) MDL-

1

4

(5) AGC-1

1

2

(5) MDA-15

(5) MDL-

1

2

(5) AGC-2

(5) MDA-20

(5) MDL-1

(5) AGC-2

1

2

(5) ABC-5

(5) MDL-1

1

2

(5) AGC-3

(5) ABC-10

(5) MDL-2

(5) AGC-4

(5) ABC-12

(5) MDL-2

1

2

(5) AGC-5

(5) ABC-15

(5) MDL-3

(5) AGC-6

(5) ABC-20

(5) MDL-4

(5) AGC-7

(5) MDL-5

(5) AGC-8

(1) FT-3 Fuse tester/puller
(1) 6-inch Crescent

®

wire stripper

Midget Fuse Kit

Catalog Number: MSK-45
Kit Contents

(3) FNM-1

(3) KTK-20

(3) FNM-2

(3) KTK-30

(3) FNM-5

(3) FNQ-5

(3) FNM-10

(3) FNQ-10

(3) FNM-15

(3) FNQ-15

(3) KTK-5

(3) FNQ-20

(3) KTK-10

(3) FNQ-30

(3) KTK-15

(1) FT-3 Fuse tester/puller

(1) 6-inch Crescent

®

wire stripper

Class CC Fuse Kit

Catalog Number: CCSK-45

Kit Contents

(3) LP-CC-5

(3) KTK-R-15

(3) LP-CC-10

(3) KTK-R-20

(3) LP-CC-15

(3) KTK-R-30

(3) LP-CC-20

(3) FNQ-R-

1

2

(3) LP-CC-30

(3) FNQ-R-3

(3) KTK-R-5

(3) FNQ-R-5

(3) KTK-R-10

(3) FNQ-R-10

(1) FT-3 Fuse tester/puller
(1) 6-inch Crescent

®

wire stripper

Branch Circuit

Supplemental

Fusetron

Class RK5

250/600V Fuse Kit

Catalog Number: RK5SK-39

Kit Contents

(3) FRN-R-10

(3) FRS-R-10

(3) FRN-R-15

(3) FRS-R-15

(3) FRN-R-20

(3) FRS-R-20

(3) FRN-R-25

(3) FRS-R-30

(3) FRN-R-30

(3) FRS-R-60

(3) FRN-R-60

(3) FRS-R-100

(3) FRN-R-100

(1) FP-2 Fuse puller

(1) NO.263-R (60 to 30A fuse reducer)
(1) NO.663-R (60 to 30A fuse reducer)
(1) 6-inch Crescent

®

wire stripper

Low-Peak

Class J Fuse Kit

Catalog Number: JSK-36

Kit Contents

(3) LPJ-3SP

(3) LPJ-25SP

(3) LPJ-5SP

(3) LPJ-30SP

(3) LPJ-6SP

(3) LPJ-40SP

(3) LPJ-10SP

(3) LPJ-50SP

(3) LPJ-15SP

(3) LPJ-60SP

(3) LPJ-20SP

(3) LPJ-100SP

(1) FP-2 Fuse puller
(1) 8

5

8

-inch Crescent

®

lineman’s pliers

Premium Branch Circuit

Low-Peak

Class RK1

250/600V Fuse Kit

Catalog Number: RK1SK-39

Kit Contents

(3) LPN-RK-10SP

(3) LPS-RK-10SP

(3) LPN-RK-15SP

(3) LPS-RK-15SP

(3) LPN-RK-20SP

(3) LPS-RK-20SP

(3) LPN-RK-25SP

(3) LPS-RK-30SP

(3) LPN-RK-30SP

(3) LPS-RK-60SP

(3) LPN-RK-60SP

(3) LPS-RK-100SP

(3) LPN-RK-100SP
(1) NO.263-R (60 to 30A fuse reducer)
(1) NO.663-R (60 to 30A fuse reducer)
(1) FP-2 Fuse puller
(1) 8

5

8

-inch Crescent

®

lineman’s pliers

Selection

These service kits are filled with the
most common fuse types and sizes for
the most common applications – no
need to search for the right fuse, it’s in
the kit.

Organization

The compact and sturdy carrying case
allows organizing and modifying the
fuses needed to assure a proper 
supply is kept on hand.

Accessories

All kits come with a fuse puller for the
fuses it contains. As a bonus, all kits on
this page include a free wire stripper or
lineman’s pliers.

Save Time and Money with These Fuse Service Kits

Fuse Kits and Accessories

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

506

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

507

Accessories

Fuse Service Kits

Low-Peak

Class RK1 250V

Fuse Kit

Compact kit in a sturdy nylon box
rugged enough to withstand field use.
Extra spaces and changeable 
compartments make it easy to 
customize for your particular need.

Catalog Number: LPRK-28

Service Kit Contents

(2) LPN-RK-3-

2

10

SP

(2) LPN-RK-40SP

(2) LPN-RK-6-

1

4

SP

(2) LPN-RK-50SP

(2) LPN-RK-10SP

(3) LPN-RK-60SP

(2) LPN-RK-15SP

(2) LPN-RK-100SP

(3) LPN-RK-20SP

(2) NO.263-R Reducers

(2) LPN-RK-25SP

(2) NO.1 Clip Clamps

(4) LPN-RK-30SP

(2) NO.2 Clip Clamps

(2) LPN-RK-35SP

(1) FP-2 Fuse puller

Fusetron

Class RK5

250V Fuse Kit

Compact kit in a sturdy nylon box
rugged enough to withstand field use.
Extra spaces and changeable 
compartments make it easy to 
customize for your particular need.

Catalog Number: ERK-28

Service Kit Contents

(2) FRN-R-3-

2

10

(2) FRN-R-40

(2) FRN-R-6-

1

4

(2) FRN-R-50

(2) FRN-R-10

(3) FRN-R-60

(2) FRN-R-15

(2) FRN-R-100

(3) FRN-R-20

(2) NO.263-R Reducers

(2) FRN-R-25

(2) NO.1 Clip Clamps

(4) FRN-R-30

(2) NO.2 Clip Clamps

(2) FRN-R-35

Class CC / Midget
Fuse Kit

Emergency fuse kit for replacement of

13

32

˝ x 1

1

2

˝ (Class CC and midget) fuses

in a sturdy nylon box. Cross reference
makes it easy to install the correct fuse
in any Class CC or midget application.

Kit Size:

10

7

8

˝ W x 6

5

8

˝ D x 1

3

4

˝ H

Catalog Number: NO.36

Emergency Kit Contents

(2) FNQ-R-

1

2

(2) KTK-R-1

(2) FNQ-R-1

(2) KTK-R-2

(2) FNQ-R-2

(2) KTK-R-3

(2) FNQ-R-3

(2) KTK-R-5

(2) FNQ-R-4

(2) KTK-R-6

(2) FNQ-R-5

(2) KTK-R-10

(2) FNQ-10

(2) KTK-R-15

(2) FNQ-15

(2) KTK-R-20

(2) FNQ-20

(2) KTK-R-30

(1) FP-2 Fuse puller

Supplemental/Branch
Circuit

Branch Circuit

Premium Branch Circuit

Fuse Kits and Accessories

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

508

Fuse Kits and Accessories

Fuse Service Kits

Fuse Kit 270

Small dimension fuse assortment with
270 fuses, fuse holders, fuse blocks and
fuse clips to fit most electronic 
equipment.

Ratings:

Volts: — 125V/250V

Catalog Number: NO.270

Assortment Contents

(5) MDL-

1

8

(5) AGC-

1

2

(5) GMA-1A

(5) MDL-

1

4

(5) AGC-

3

4

(5) GMA-2A

(5) MDL-

1

2

(5) AGC-1

(5) GMA-3A

(5) MDL-

3

4

(5) AGC-1-

1

2

(5) GMA-4A

(5) MDL-1

(5) AGC-2

(5) GMA-6A

(5) MDL-1-

1

2

(5) AGC-2-

1

2

(5) GMC-1A

(5) MDL-2

(5) AGC-3

(5) GMC-2A

(5) MDL-3

(5) AGC-4

(5) GMC-3A

(5) MDL-4

(5) AGC-5

(5) GMC-4A

(5) MDL-5

(5) AGC-6

(5) GMC-6A

(5) MDL-6

(5) AGC-7

(4) AGC-V-

1

2

(5) MDA-8

(5) AGC-8

(4) AGC-V-1

(5) MDA-10

(5) ABC-10

(4) AGC-V-2

(5) MDA-15

(5) ABC-15

(4) AGC-V-3

(5) MDA-20

(5) ABC-20

(4) MDL-V-

1

2

(5) MDA-30

(5) ABC-30

(4) MDL-V-1

(5) AGC-

1

8

(5) GMA-250mA

(4) MDL-V-2

(5) AGC-

1

4

(5) GMA-500mA

(4) MDL-V-3

(2) Pr. 4121 Fuse clips
(2) HHB Inline fuse holder
(1) HTB-26I panel mount fuse holder
(1) HTB-28M panel mount fuse holder
(1) S-8202-2 Two-pole fuse block

Fuse Kit 140

Small dimension fuse kit with 140
fuses, fuse holders, fuse blocks and
fuse clips to fit most electronic 
equipment.

Ratings:

Volts: — 125V/250V

Catalog Number: NO.140

Assortment Contents

(5) MDL-

1

2

(5) AGC-1-

1

2

(5) MDL-1

(5) AGC-2

(5) MDL-1-

1

2

(5) AGC-3

(5) MDQ-2

(5) MTH-4

(5) MDQ-3

(5) MTH-5

(5) MDQ-4

(5) MTH-6

(5) MDQ-5

(5) MTH-7

(5) MDQ-6

(5) MTH-8

(5) MDA-8

(5) ABC-10

(5) MDA-10

(5) ABC-15

(5) MDA-15

(5) ABC-20

(5) MDA-20

(5) ABC-30

(5) MDA-30

(2) Pr. #4121 Fuse clips

(5) AGC-

1

4

(2) HHB Inline fuse holder

(5) AGC-

1

2

(1) FP-A3 Fuse puller

(5) AGC-1

5 x 20mm Fuse Kit 220

A complete assortment of 125V and
250V 5 x 20mm fuses for the repair of
both electrical and electronic devices.

Ratings:

Volts: — 125V/250V

Catalog Number: NO.220

Assortment Contents

(5) GMA-250mA (5) GDA-6.3

(5) GMD-200mA

(5) GMA-500mA (5) GDB-630mA

(5) GMD-500mA

(5) GMA-1

(5) GDB-2

(5) GMD-1

(5) GMA-1.5

(5) GDB-3.15

(5) GMD-1.6

(5) GMA-2

(5) GDB-4

(5) GMD-2

(5) GMA-2.5

(5) GMC-500mA

(5) GMD-3

(5) GMA-3

(5) GMC-750mA

(5) GDC-250mA

(5) GMA-4

(5) GMC-1

(5) GDC-500mA

(5) GMA-5

(5) GMC-2

(5) GDC-1

(5) GMA-10

(5) GMC-2.5

(5) GDC-1.6

(5) GDA-630mA (5) GMC-3

(5) GDC-2

(5) GDA-1

(5) GMC-3.15

(5) GDC-3.15

(5) GDA-2

(5) GMC-4

(5) GDC-4

(5) GDA-3.15

(5) GMC-5

(5) GDC-5

(5) GDA-5

(5) GMC-6.3

(1) HTB-28M panel mount fuse holder
(1) FP-A3 Fuse puller

Large Electronic Fuse Kit

Small Electronic Fuse Kit

Electrical and Electronic
Fuse Kit

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

509

Accessories

Adapters for DIN and American Rails

Specifications
Description:

Bussmann DIN-Rail
adapters permit secure,
positive snap-on mounting
of Bussmann 0-30A fuse
blocks (one-, two-, or
three-pole) onto various
size rails to eliminate 
costly and time consuming
drilling, tapping, and screw
mounting. Adapters 
mechanically lock into 
mounting holes of fuse blocks in 
seconds to become an integral part of the block.
One adapter is required for one- and two-pole Bussmann
blocks. Two adapters are required for three-pole blocks.

With the exception of the 32mm DIN-Rail, all blocks with
adapters can be removed from a rail simply by pulling up its
release tab.

Use of rail end-stops on both sides of adapters is 
recommended.

Construction:

Molded from “Lexan™ 241” for high strength

and flexibility.

Catalog Numbers (For 0-30A Fuse Blocks)

Catalog

Fuse Block

Adapter

Numbers

Class

Rail Type

Size

Color

DRA-1

CC

DIN

15mm (Sym.)

Black

G

32mm (Asym.)

*H (250V)

35mm (Sym.)

DRA-2

*R (250)

American

17

64

˝ (Sym.)

Gray

M Type

(also 35mm DIN)

Package Quantities: standard—10; bulk—100 (Cat. No. BK/DRA-1 or BK/DRA-2.)
*Mounting on 15mm rails is not recommended.
NOTE—Newer Bussmann fuse blocks have elongated block-to-adapter mounting holes (old
style fuse blocks will not accept the rail adapters).

Clip Clamps and Rail Adapters (DIN & American)

TRON™ Clip-Clamps

Specifications
Description:

Clamps

for ferrule and blade-
type cartridge fuse
clips. Provide tight
contacts between fuse
holder clips and fuse
ferrules/blades.

Construction:

Phenolic knob and
plated-steel jaws.

Catalog Numbers

Catalog

Clamp Size

Numbers

Volts

Amps

NO.1

250

0-30

NO.2

250

35-60

NO.2

600

0-30

NO.4

600

35-60

NO.5

250/600

70-100

NO.6

250/600

110-200

NO.7

250/600

225-400

NO.8

250/600

450-600

Fuse Kits and Accessories

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Fuse Pullers

Specifications
Description:

Fuse pullers in various

sizes to safely and easily extract fuses
from blocks and holders.

Catalog Numbers

Ca

t

alog Numbers

Application

FP-2

13

32

˝ to 

13

16

˝ dia. fuses

FP-3

1˝ to 1 

3

4

˝ dia. fuses

FP-4

3

4

˝ to 2 

1

2

˝ dia. fuses

FP-6

0-60A T-Tron fuses

FP-A3

Glass Tube & ATC fuses

CFP-30

CUBEFuse 1-30A

CFP-60

CUBEFuse 35-60A

CFP-100

CUBEFuse 70-100A

Fuse pullers are only to be used when the associated circuit
has been de-energized.

Spare Fuse Holders

Specifications
Description:

Spare fuse holders

durably constructed using black 
thermoplastic with common mounting
using #6 screws or bolts on 5-inch 
centers. Dovetailed interlocking between
fuse holders simplifies installation and
reduces needed hardware. Common
footprint allows for any combination of
fuse holders to be mounted together.
Built-in retaining clips secure fuses.

Flammability Rating:

UL 94V0.

Catalog Numbers

Catalog
Numbers

Capacity

For Use With:

TPSFH-CW

4-position

TPC and/or TPW fuses

TPSFH-M

4-position

TPM fuses

TPSFH-LC

1-position

TPL-C series fuses

TPSFH-LB

1-position

TPL-B series fuses

TPSFH-N60

1-position

TPN (35-60A) fuses

TPSFH-N30

4-position

TPN (1-30A) fuses

TPSFH-AS

6-position

TPA & TPS fuses

TPSFH-T

10-position

GMT fuses

Spare Fuse Holders, Pullers, Testers and Cabinets

Data Sheet: 1119

SFC Spare Fuse Cabinet

Specifications
Description:

Spare fuse cabinet with

five cubic feet of storage space.
Constructed of heavy gauge steel with
durable baked ASA 61 grey enamel 
finish. Cabinet door is equipped with
locking handle for security. Mounting
holes are 16 inches on center with key
slots.

Size:

24˝ W x 30˝ H x 12˝ D

Material:

0.062 sheet steel

Catalog Numbers:

SFC-FUSE-CAB

SFC-SHELF*

*Extra shelf for fuse cabinet.

5TPH

Specifications
Description:

5-position spare fuse 

holder for midget size and Class CC
fuses (

13

32

˝ diameter) fuses. Constructed

of thermoplastic with adhesive tape on
back for easy mounting on cabinet doors.

Size:

2.98˝ W x 1.03˝ H x 0.63˝  D

Catalog Number: 5TPH

Data Sheet: 5014

FT-2 Fuse Tester

Specifications
Description:

Fuse tester for automotive,

glass tube and ferrule fuses up to 1

7

8

˝

length. Probe slides to appropriate fuse
length. Batteries are included and
replaceable.

WARNING

DO NOT

test electrical

fuses in the fuse panel.

Catalog Number: FT-2

Replacement Battery:

Rayovac 364

FT-3 Fuse Tester

Specifications
Description:

Fuse tester for 

automotive, glass tube and ferrule
fuses up to 1

1

4

˝ length. Probe slides  

to appropriate fuse length. Batteries
are included and replaceable.

WARNING

DO NOT

test electrical

fuses in the fuse panel.

Catalog Number: FT-3

FP-4

FP-A3

FP-6

FP-3

FP-2

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

510

Fuse Kits and Accessories

CFP-_ _ _A

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

511

Accessories

Fuse Reducers and Dummy “Neutrals”

Data Sheet: 1118

Fuse Reducers for Class J Fuses: 
LPJ, DFJ, JKS

Catalog Numbers

Catalog

Numbers (Pair)

Fuse

Equipment/Fuseblock

Reducer No.

Amp Size Range

Amp Size

J-63

1-30

60

J-13

1-30

100

J-16

35-60

100

J-26

35-60

200†

J-21

70-100

200†

J-41

70-100

400†

J-42

110-200

400†

J-62

110-200

600†

J-64

225-400

600†

†Not for Bolt-on Applications.

Fuse Reducers for Class R Fuses: 
FRN-R, LPN-RK, FRS-R, LPS-RK
KTN-R, KTS-R

UL Listed File E12853

Catalog Numbers

Catalog Numbers (Pairs)
Voltages

Fuse

Equipment/Fuseblock

250V

600V

Amp Size Range

Amp Size

NO.263-R

NO.663-R

1-30

60

NO.213-R

NO.216-R

1-30

100

NO.216-R

NO.616-R

35-60

100

NO.226-R

NO.626-R

35-60

200

NO.2621-R

NO.2621-R

70-100

200

NO.2641-R

NO.2641-R

70-100

400

NO.242-R

NO.642-R

110-200

400

NO.2661-R

NO.2661-R

70-100

600

NO.2662-R

NO.2662-R

110-200

600

NO.2664-R**

NO.2664-R**

225-400

600

**Single reducer only (pair not required).

Fuse Reducers for Class H & K Fuses:
NON, REN, NOS, RES

UL Listed File E12853

Catalog Numbers

Catalog Numbers. (Pairs)

Equipment/

250V

600V

Fuse

Fuseblock

Reducer

Reducer

Amp Size Range

Amp Size

NO.263

NO.663

1-30

60

NO.213

NO.216

1-30

100

NO.216

NO.616

35-60

100

NO.226

NO.626

35-60

200

NO.2621

NO.2621

70-100

200

NO.2641

NO.2641

70-100

400

NO.2642

NO.2642

110-200

400

No. 2661

No. 2661

70-100

600

Dummy Fuse “Neutrals” 
(These are not fuses)

Catalog Numbers

Fuse Equivalent

Catalog

Fuse

Numbers

Voltage

Dimension

Amp Size Range

NNB

13

32

˝ x 1

1

2

˝

NNB-R

Class CC

NNC

1

4

˝ x 1

1

4

NTN-R-30

250

R/H

1-30

NTN-R-60

250

R/H

35-60

NTN-R-100

250

R/H

70-100

NTN-R-200

250

R/H

110-200

NTN-R-400

250

R/H

225-400

NTS-R-30

600

R/H

1-30

NTS-R-60

600

R/H

35-60

NTS-R-100

600

R/H

70-100

NTS-R-200

600

R/H

110-200

NTS-R-400

600

R/H

225-400

NTS-R-600

600

R/H

450-600

Fuse Kits and Accessories

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

512

Finger-safe DIN-Rail mount fuse 
holders protect your electrical 
system & simplify installation

Compact modular 
fuse holders

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

513

Ser

vices &

A

pplication Guide

RED 

indicates

NEW 

information

Bussmann
Services & Application
Guide

Section Contents

Bussmann Services

Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 514

Custom Products . . . . . . . . . . . . . . . . . . . . . . . . . 515
Application Guide

Fuse technology . . . . . . . . . . . . . . . . . . . . . . . . . . .516-522

Motor circuit branch circuit protection . . . . . . . . . . . . . . .523

Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  524-526

Out-of-stock substitution/upgrades . . . . . . . . . . . . . . . . 526

Industrial & commercial fuse applications . . . . . . . . . . . 527

Catalog number index . . . . . . . . . . . . . . . . .  528-???

Sales support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .???

Downtime Reduction, Workplace 
Safety & Code Compliance

Services to Increase Your Productivity Through Protection

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Visit www.cooperbussmann.com

514

Services

Testing

Performance and Compliance Certification for
Components and Assemblies 

The Bussmann Paul P. Gubany Center for High Power
Technology at Bussmann is the electrical industry’s most 
comprehensive facility for testing and certifying electrical 
components and assemblies.  

OEM customers make the Gubany Center their first choice in
testing equipment such as:

• Drives, both AC and DC

• Circuit breakers

• Motor control centers

• Soft starters

• Fuses

• Power distribution panels

• Surge suppressors

• Cables 

Our technicians conduct tests to many global agency 
standards including: 

Wide Range of Capability

Built to exceed the short circuit capacity of today’s high power
electrical distribution systems, the Gubany Center performs:

• Ultra-high power testing from 200kA to 300kA at 600Vac,

three-phase

• Medium power testing from 5kA to 200kA at 600Vac, 

single- and three-phase; to 100kA at 1450Vac single-phase;
to 100kA at 1000Vdc

• Low power testing up to 5kA at 600Vac, single-phase.

Description

Catalog Number

High Power Testing

Hourly Rate

CBSV-ES-TEHP

Medium Power Testing

Hourly Rate

CBSV-ES-TEMP

Low Power Testing

Hourly Rate

CBSV-ES-TELP

Testing Catalog Numbers

To Order:

To find out more contact your local
Bussmann representative, 
or visit us online at 

www.cooperbussmann.com/services

.

• ANCE

• ANSI

• CE

• CSA

• ETL

• IEC, and

• Underwriters 

Laboratories

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

515

Ser

vices &

A

pplication Guide

Custom Products

Creating the Right Answers to Unique or Demanding
Needs

When you wish to gain a competitive edge or improve your
product's performance, have Busmann provide a custom
product that can: 

• Improve functionality and utility

• Fit unique design needs

• Reduce labor and component costs

Our Expertise Is Your Advantage

For almost 100 years, Bussmann has designed and 
manufactured products that improve electrical safety and 
performance. Whether it's modifying an existing product or
creating a new one, our experience effectively brings together
the skills to design, prototype, test, manufacture and secure
agency approvals to deliver a single component, 
sub-assembly or finished product. 

Busmann can design and manufacture products that 
integrate: 

• Fuses - with the right size and performance 

characteristics

• Fuse holders and blocks - with the requisite terminations,

mounting options and safety features

• Wire connection products - that make wiring simpler, 

safer and faster

• Molded products - that give the unique shape your 

product needs

• Power distribution products - that meet prevailing agency 

and Code requirements

In-House Testing

All electrical performance testing of your custom products
can be performed at the Bussmann Paul P. Gubany Center
for High Power Technology, an ASTA and CSA accredited,
and an ANCE Designated facility.

We're able to conduct electrical performance testing that
replicates any power system to be encountered in any 
country, covering:

• Up to 300kA and 600Vac

• Up to 100kA and 1000Vdc

And our technicians conduct tests to many global agency
standards including: 

• ANCE

• ANSI

• CE

• CSA

• ETL

• IEC, and

• Underwriters Laboratories

To Find Out More:

If you need a custom solution to a product problem, submit a
Request for Quotation to your local authorized Bussmann 
distributor or sales representative.

Services

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

516

Application Guide

Fuse Technology

Circuit Protection

The following is a basic introduction to overcurrent protection
and fuse technology. In depth information on the selection and
application of overcurrent protective devices is available in the
Bussmann publication “Selecting Protective Devices” (SPD).
This publication is available free of charge as a PDF download
at 

www.cooperbussmann.com/spd

.

Electrical distribution systems are often quite complicated.
They cannot be absolutely fail-safe. Circuits are subject to
destructive overcurrents. Harsh environments, general 
deterioration, accidental damage, damage from natural 
causes, excessive expansion, and/or overloading of the 
electrical distribution system are factors which contribute to the 
occurrence of such overcurrents. Reliable protective devices
prevent or minimize costly damage to transformers, 
conductors, motors, and the other many components and
loads that make up the complete distribution system. Reliable
circuit protection is essential to avoid the severe monetary
losses which can result from power blackouts and prolonged
downtime of facilities. It is the need for reliable protection, 
safety, and freedom from fire hazards that has made the fuse a
widely used protective device.

Overcurrents

An overcurrent is either an overload current or a short-circuit
current. The overload current is an excessive current relative to
normal operating current, but one which is confined to the 
normal conductive paths provided by the conductors and other
components and loads of the distribution system. As the name
implies, a short-circuit current is one which flows outside the
normal conducting paths.

Overloads

Overloads are most often between one and six times the 
normal current level. Usually, they are caused by harmless
temporary surge currents that occur when motors are 
started-up or transformers are energized. Such overload 
currents, or transients, are normal occurrences. Since they are
of brief duration, any temperature rise is trivial and has no
harmful effect on the circuit components. (It is important that
protective devices do not react to them.)

Continuous overloads can result from defective motors (such as
worn motor bearings), overloaded equipment, or too many loads
on one circuit. Such sustained overloads are destructive and
must be cut off by protective devices before they damage the
distribution system or system loads. However, since they are of
relatively low magnitude compared to short-circuit currents,
removal of the overload current within minutes will generally 
prevent equipment damage. A sustained overload current results
in overheating of conductors and other components and will
cause deterioration of insulation, which may eventually result in
severe damage and short-circuits if not interrupted.

Short-Circuits

Whereas overload currents occur at rather modest levels, the
short-circuit or fault current can be many hundred times larger
than the normal operating current. A high level fault may be

50,000A (or larger). If not cut off within a matter of a few 
thousandths of a second, damage and destruction can become
rampant—there can be severe insulation damage, melting of
conductors, vaporization of metal, ionization of gases, arcing,
and fires. Simultaneously, high level short-circuit currents can
develop huge magnetic-field stresses. The magnetic forces
between bus bars and other conductors can be many hun-
dreds of pounds per linear foot; even heavy bracing may not
be adequate to keep them from being warped or distorted 
beyond repair.

Fuses

The fuse is a reliable overcurrent protective device. A “fusible”
link or links encapsulated in a tube and connected to contact
terminals comprise the fundamental elements of the basic
fuse. Electrical resistance of the link is so low that it simply
acts as a conductor. However, when destructive currents occur,
the link very quickly melts and opens the circuit to protect 
conductors, and other circuit components and loads. Fuse 
characteristics are stable. Fuses do not require periodic 
maintenance or testing. Fuses have three unique performance
characteristics:

1.  Modern fuses have an extremely “high interrupting rating”—can 

withstand very high fault currents without rupturing.

2.  Properly applied, fuses prevent “blackouts.” Only the fuse nearest a fault

opens without upstream fuses (feeders or mains) being affected—fuses
thus provide “selective coordination.” (These terms are precisely defined
in subsequent pages.)

3.  Fuses provide optimum component protection by keeping fault currents

to a low value…They are said to be “current limiting.”

Voltage Rating

The voltage rating of a fuse must be at least equal to or
greater than the circuit voltage. It can be higher but never
lower. For instance, a 600V fuse can be used in a 208V circuit.

The voltage rating of a fuse is a function of its capability to
open a circuit under an overcurrent condition. Specifically, the
voltage rating determines the ability of the fuse to suppress the
internal arcing that occurs after a fuse link melts and an arc is
produced. If a fuse is used with a voltage rating lower than the
circuit voltage, arc suppression will be impaired and, under
some fault current conditions, the fuse may not clear the 
overcurrent safely. Special consideration is necessary for 
semiconductor fuse and medium voltage fuse applications,
where a fuse of a certain voltage rating is used on a lower 
voltage circuit.

Amp Rating

Every fuse has a specific amp rating. In selecting the amp 
rating of a fuse, consideration must be given to the type of load
and code requirements. The amp rating of a fuse normally
should not exceed the current carrying capacity of the circuit.
For instance, a continuous load current of 16 amperes typically
requires a conductor rated to carry 20A and a 20A fuse is the
largest that should be used. However, there are some 
specific circumstances in which the amp rating is permitted to
be greater than the current carrying capacity of the circuit. 

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

517

Ser

vices &

A

pplication Guide

Application Guide

Fuse Technology

A typical example is the motor circuit; dual-element fuses 
generally are permitted to be sized up to 175% and non-time-
delay fuses up to 300% of the motor full-load amps. As a rule,
the amp rating of a fuse and switch combination should be
selected at 125% of the continuous load current (this usually
corresponds to the circuit capacity, which is also selected at
125% of the load current). There are exceptions, such as when
the fuse-switch combination is approved for continuous 
operation in an assembly at 100% of its rating.

Interrupting Rating

A protective device must be able to withstand the destructive
energy of short-circuit currents. If a fault current exceeds the
capability of the protective device, the device may actually 
rupture, causing additional damage. Thus, it is important when
applying a fuse or circuit breaker to use one which can sustain
the largest potential short-circuit currents. The rating which
defines the capacity of a protective device to maintain its
integrity when reacting to fault currents is termed its 
“interrupting rating”. The interrupting rating of most 
branch-circuit, molded case, circuit breakers typically used in 
residential service entrance panels is 10,000A. Larger, more
expensive circuit breakers may have interrupting ratings of
14,000A or higher. In contrast, most modern, current-limiting
fuses have an interrupting rating of 200,000 or 300,000A and
are commonly used to protect the lower rated circuit breakers.
The National Electrical Code, Section 110-9, and §OSHA 29
CFR 1910.303(b)(4) require equipment intended to break 
current at fault levels to have an interrupting rating sufficient for
the current that must be interrupted.

Selective Coordination – Prevention of Blackouts

Coordination is isolation of an overloaded or faulted circuit by
the opening of only the nearest upstream protective device for
a specific overcurrent value. When only the nearest upstream
protective device of an overloaded or faulted circuit opens and
larger upstream fuses remain closed for the full range of 
overcurrents on a system, the protective devices are 
“selectively” coordinated (they discriminate).   Selective 
coordination of protective devices prevents unnecessary 
system power outages or blackouts caused by overcurrent
conditions.

This diagram shows the minimum ratios of amp ratings of Low-Peak
Yellow fuses that are required to provide “selective coordination” 
(discrimination) of upstream and downstream fuses.

It is a simple matter to selectively coordinate modern current-
limiting fuses. By maintaining a minimum ratio of fuse-amp 
ratings between an upstream and downstream fuse, selective 
coordination is assured.

Current Limitation – Component Protection

A non-current-limiting protective device, by permitting a short-
circuit current to build up to its full value, can let an immense
amount of destructive short-circuit heat energy through before
opening the circuit.

A current-limiting fuse has such a high speed of response that
it cuts off a short-circuit long before it can build up to its full
peak value, when the fault current is within the current-limiting
range of a fuse.

If a protective device cuts off a short-circuit current in less than
one-half cycle, before it reaches its total available (and highly
destructive) value, the device is a “current-limiting” device.
Most modern fuses are current-limiting. They restrict fault 
currents to such low values that a high degree of protection is
given to circuit components against even very high short-circuit
currents. They permit breakers with lower interrupting ratings to
be used when series rated. They can reduce bracing of bus
structures. They minimize the need of other components to
have high short-circuit current “withstand” ratings. If not limited,
short-circuit currents can reach levels of 30,000 or 40,000A or
higher in the first half cycle (.008 seconds, 60Hz) after the start
of a short-circuit. The heat that can be produced in circuit 
components by the immense energy of short-circuit currents
can cause severe insulation damage or even explosion. At the
same time, huge magnetic forces developed between 
conductors can crack insulators and distort and destroy 
bracing structures. Thus, it is important that a protective device
limit fault currents before they reach their full potential level.

KRP-C
1200SP

2:1 (or more)

LPS-RK
600SP

LPS-RK
200SP

2:1 (or more)

Initiation of
short-circuit 
current

Normal
load current

Areas within waveform
loops represent destructive
energy impressed upon
circuit components

Circuit breaker trips
and opens short-circuit
in about 1 cycle

Fuse opens and clearsr

short-circuit in lessr

than ⁄Ω™ cycle

Not current-limiting

Current-limiting

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

518

Application Guide

Fuse Technology

Operating Principles of Bussmann Fuses

The principles of operation of the modern, current-limiting
fuses are covered in the following paragraphs.

Non-Time-Delay Fuses

The basic component of a fuse is the link. Depending upon the
amp rating of the fuse, the single-element fuse may have one
or more links. They are electrically connected to the end
blades (or ferrules) (see Figure 1) and enclosed in a tube or
cartridge surrounded by an arc quenching filler material.
Bussmann Limitron

and T-Tron

fuses are both 

single-element fuses.

Under normal operation, when the fuse is operating at or near
its amp rating, it simply functions as a conductor. However, as
illustrated in Figure 2, if an overload current occurs and 
persists for more than a short interval of time, the temperature
of the link eventually reaches a level which causes a restricted
segment of the link to melt. As a result, a gap is formed and an
electric arc established. However, as the arc causes the link
metal to burn back, the gap becomes progressively larger.
Electrical resistance of the arc quickly reaches such a high
level that the arc cannot be sustained and is extinguished. The
fuse will have then completely cut off all current flow in the 
circuit. Suppression or quenching of the arc is accelerated by
the filler material. (See Figure 3.)

Single-element fuses of present day design have a very high
speed of response to overcurrents. They provide excellent
short-circuit component protection. However, temporary, 
harmless overloads or surge currents may cause nuisance
openings unless these fuses are oversized. They are best
used, therefore, in circuits not subject to heavy transient surge
currents and the temporary over-load of circuits with inductive
loads such as motors, transformers, solenoids, etc. Because
single-element, fast-acting fuses such as Limitron and 
T-Tron fuses have a high speed of response to short-circuit
currents, they are particularly suited for the series rating 
protection of circuit breakers with low interrupting ratings.

Whereas an overload current normally falls between one and
six times normal current, short-circuit currents are quite high.
The fuse may be subjected to short-circuit currents of 30,000
or 40kA or higher. Response of current limiting fuses to such
currents is extremely fast. The restricted sections of the fuse
link will simultaneously melt (within a matter of two or three-
thousandths of a second in the event of a high-level fault 
current).

The high total resistance of the multiple arcs, together with the
quenching effects of the filler particles, results in rapid arc 
suppression and clearing of the circuit. (Refer to Figures 4 & 5)
Short-circuit current is cut off in less than a half-cycle, long
before the short-circuit current can reach its full value (fuse
operating in its current limiting range).

Figure 2. Under sustained overload, a section of the link melts and an
arc is established.

Figure 3. The “open” single-element fuse after opening a circuit 
overload.

Figure 4. When subjected to a short-circuit current, several sections
of the fuse link melt almost instantly.

Figure 5. The “open” single-element fuse after opening a short circuit.

Figure 1. Cutaway view of typical single-element fuse.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

519

Ser

vices &

A

pplication Guide

Application Guide

Fuse Technology

Bussmann Dual-Element Fuses

There are many advantages to using these fuses. Unlike single-element fuses, the Bussmann dual-element, time-delay fuses can be sized closer to provide both high 
performance short-circuit protection and reliable overload protection in circuits subject to temporary overloads and surge currents. For ac motor loads, a single-element fuse
may need to be sized at 300% of an a.c. motor current in order to hold the starting current. However, dual-element, time delay fuses can be sized much closer to motor
loads. For instance, it is generally possible to size Fusetron Dual-Element Fuses, FRS-R and FRN-R and Low-Peak

Dual-Element Fuses, LPS-RK_SP and LPN-RK_SP, at

125% and 130% of motor full load current, respectively. Generally, the Low-Peak Dual-Element Fuses, LPJ_SP, and CUBEFuse

, TCF, can be sized at 150 to 175% of motor

full load amps. This closer fuse sizing may provide many advantages such as: (1) smaller fuse and block, holder or disconnect amp rating and physical size, (2) lower cost
due to lower amp rated devices and possibly smaller required panel space, (3) better short-circuit protection – less short-circuit current let-through energy, and (4) potential
reduction in the arc-flash hazard.

Figure 6. 

This is the LPS-RK100SP, a 100A, 600V Low-Peak, Class RK1, Dual-Element Fuse that has excellent time-delay, excellent current-limitation and a 300kA interrupting rating. Artistic 

liberty is taken to illustrate the internal portion of this fuse. The real fuse has a non-transparent tube and special small granular, arc-quenching material completely filling the internal space. 

Figure 7. 

The true dual-element fuse has distinct and separate overload element and short-

circuit element. 

Short-circuit element

Overload element

Spring

Filler quenches the arcs

Small volume of metal to vaporize

Filler material

Insulated end-caps to help prevent
accidental contact with live parts.

Figure 8. 

Overload operation: Under sustained overload conditions, the trigger spring

fractures the calibrated fusing alloy and releases the “connector”. The insets represent a model
of the overload element before and after. The calibrated fusing alloy connecting the short-circuit
element to the overload element fractures at a specific temperature due to a persistent overload
current. The coiled spring pushes the connector from the short-circuit element and the circuit is
interrupted. 

Figure 9. 

Short-circuit operation: Modern fuses are designed with minimum metal in the

restricted portions which greatly enhance their ability to have excellent current-limiting
characteristics – minimizing the short circuit let-through current. A short-circuit current causes
the restricted portions of the short-circuit element to vaporize and arcing commences. The arcs
burn back the element at the points of the arcing. Longer arcs result, which assist in reducing the 
current. Also, the special arc quenching filler material contributes to extinguishing the arcing
current. Modern fuses have many restricted portions, which results in many small arclets – all
working together to force the current to zero. 

Figure 10. 

Short-circuit operation: The special small granular, arc-quenching material plays

an important part in the interruption process. The filler assists in quenching the arcs; the filler
material absorbs the thermal energy of the arcs, fuses together and creates an insulating barrier.
This process helps in forcing the current to zero. Modern current-limiting fuses, under short-
circuit conditions, can force the current to zero and complete the interruption within a few
thousandths of a second. 

When the short-circuit current is in the current-limiting range of a fuse, it is not possible for the full available short-circuit current to flow through the fuse – it’s a matter of
physics. The small restricted portions of the short-circuit element quickly vaporize and the filler material assists in forcing the current to zero. The fuse is able to “limit” the
short-circuit current.

Overcurrent protection must be reliable and sure. Whether it is the first day of the electrical system or thirty or more years later, it is important that overcurrent protective
devices perform under overload or short-circuit conditions as intended. Modern current-limiting fuses operate by very simple, reliable principles. 

Before

After

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

520

Application Guide

Fuse Technology

Fuse Time-Current Curves

When a low level overcurrent occurs, a long interval of time will
be required for a fuse to open (melt) and clear the fault. On the
other hand, if the overcurrent is large, the fuse will open very
quickly. The opening time is a function of the magnitude of the
level of overcurrent. Overcurrent levels and the corresponding
intervals of opening times are logarithmically plotted in graph
form as shown to the right. Levels of overcurrent are scaled on
the horizontal axis; time intervals on the vertical axis. The
curve is thus called a “time-current” curve.

This particular plot reflects the characteristics of a 200A, 250V,
Low-Peak

dual-element fuse. Note that at the 1,000A 

overload level, the time interval which is required for the fuse
to open is 10 seconds. Yet, at approximately the 2,200A 
overcurrent level, the opening (melt) time of a fuse is only 0.01
seconds. It is apparent that the time intervals become shorter
as the overcurrent levels become larger. This relationship is
termed an inverse time-to-current characteristic. Time-current
curves are published or are available on most commonly used
fuses showing “minimum melt,” “average melt” and/or “total
clear” characteristics. Although upstream and downstream
fuses are easily coordinated by adhering to simple amp ratios,
these time-current curves permit close or critical analysis of 
coordination.

Better Motor Protection in Elevated Ambients

The derating of dual-element fuses based on increased 
ambient temperatures closely parallels the derating curve of
motors in elevated ambient. This unique feature allows for 
optimum protection of motors, even in high temperatures.

Affect of ambient temperature on operating characteristics of
Fusetron and Low-Peak dual-element fuses.

400

300

200

100

80

60

40

30

20

10

8

6

4

3

2

1

.8

.6

.4
.3

.2

.1

.08
.06

.04

.03

.02

.01

100

200

300

400

600

800

1,000

2,000

3,000

4,000

6,000

8,000

10,000

TIME IN SECONDS

CURRENT IN AMPS

LOW-PEAK
LPN-RK200 SP (RK1)

150

140

130

120

110

100

90

80

70

60

50

40

30

AMBIENT

PERCENT OF RATING OR

OPENING TIME

Affect on Carrying
Capacity Rating

Affect on
Opening Time

–76

°

F

(–60

°

C)

–40

°

F

(–40

°

C)

–4

°

F

(–20

°

C)

–32

°

F

(0

°

C)

68

°

F

(20

°

C)

104

°

F

(40

°

C)

140

°

F

(60

°

C)

176

°

F

(80

°

C)

212

°

F

(100

°

C)

Below is a rerating chart for single element fuses or non dual element fuses.

Ambient affect chart for non-dual-element fuses.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

521

Ser

vices &

A

pplication Guide

Application Guide

Fuse Technology

older type Class H, ONE-TIME and RENEWABLE fuses from
being installed. The use of Class R fuse holders is thus an
important safeguard. The application of Class R fuses in such
equipment as disconnect switches permits the equipment to
have a high interrupting rating. NEC

®

110-9 and §OSHA 29

CFR 1910.303(b)(4) require that protective devices have 
adequate capacity to interrupt short-circuit currents. Article
240-60(b) requires fuse holders for current-limiting fuses to
reject non-current-limiting type fuses. In the above illustration,
a grooved ring in one ferrule provides the rejection feature of
the Class R fuse in contrast to the lower interrupting rating,
non-rejection type.

Branch-Circuit Listed Fuses

Branch-circuit listed fuses are designed to prevent the 
installation of fuses that cannot provide a comparable level of
protection to equipment.

The characteristics of Branch-circuit fuses are:

1.  They must have a minimum interrupting rating of 10kA
2.  They must have a minimum voltage rating of 125V.
3.  They must be size rejecting such that a fuse of a lower 

voltage rating cannot be installed in the circuit.

4.  They must be size rejecting such that a fuse with a current 

rating higher than the fuse holder rating cannot be installed.

Better Protection Against Motor Single Phasing

When secondary single-phasing occurs, the current in the
remaining phases increases to approximately 200% rated full
load current. (Theoretically 173%, but change in efficiency and
power factor make it about 200%.) When primary single-
phasing occurs, unbalanced voltages occur on the motor circuit
causing currents to rise to 115%, and 230% of normal running
currents in delta-wye systems.

No overcurrent protective device sized only for motor branch
circuit short-circuit, ground fault protection will provide single-
phasing protection for 3-phase motors.  Single-phasing causes
are numerous including the utility system that supplies the ser-
vice losing a phase.  Single-phasing is not a serious concern
for 3-phase motors when properly protected by three properly
sized and calibrated overload protective devices.  Many solid
state motor controllers will sense and cause the motor con-
troller to open for serious unbalanced voltage situations
caused by single-phasing.  FRN-R, FRS-R, LPN-R_SP and
LPS-R_SP dual-element fuses sized for motor running over-
load protection will help to protect motors against the possible
damages of single-phasing.  In addition, additional unbalanced
voltage protection can be incorporated into motor protection
schemes, if desired.  For more information refer to the Cooper
Bussmann Selecting Protective Devices publication, section
Voltage Unbalance & Single-Phasing.

Classes of Fuses

Safety is the industry mandate. However, proper selection,
overall functional performance and reliability of a product are
factors which are not within the basic scope of listing agency
activities. In order to develop its safety test procedures, listing
agencies develop basic performance and physical 
specifications or standards for a product. In the case of fuses,
these standards have culminated in the establishment of 
distinct classes of low-voltage (600V or less) fuses; Classes
RK1, RK5, G, L, T, J, H and CC being the more important.

The fact that a particular type of fuse has, for instance, a 
classification of RK1, does not signify that it has the identical
function or performance characteristics as other RK1 fuses. In
fact, the Limitron

non-time-delay fuse and the Low-Peak 

dual-element, time-delay fuse are both classified as RK1.
Substantial differences in these two RK1 fuses usually requires
considerable difference in sizing. Dimensional specifications of
each class of fuse does serve as a uniform standard.

Class R Fuses

Class R (“R” for rejection) fuses are high performance, 

1

10

to

600A units, 250V and 600V, having a high degree of current
limitation and a short-circuit interrupting rating of 200kA or
300kA (RMS Sym.). Bussmann Class R fuses include Class
RK1 Low-Peak

and Limitron

fuses, and RK5 Fusetron fuses.

They have replaced the K1 Low-Peak and Limitron fuses and
K5 Fusetron fuses. These fuses are identical, with the 
exception of a modification in the mounting configuration called
a “rejection feature.” This feature permits Class R fuses to be
mounted in rejection type fuseclips. “R” type fuseclips prevent

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

522

Application Guide

Fuse Technology

Reliability and Maintenance of
Overcurrent Protective Devices

Whether the first day of the electrical system or years later, it
is important that overcurrent protective devices perform under
overload and fault conditions as intended.

Modern current-limiting fuses operate by very simple, reliable
principles. Fuses do not have to be maintained. By their 
inherent design, fuses do not have elements or mechanisms
to calibrate, adjust or lubricate. If and when fuses are called
upon to open on an overcurrent, installing the same type and
ampere rated fuses provides the circuit with new factory-
calibrated protection. The original design integrity can be 
maintained throughout the life of the electrical system. One
last point on fuse systems; the terminations, clips and
disconnects should be maintained as necessary.

Supplementary Overcurrent Protective
Devices for use in Motor Control
Circuits

Branch Circuit vs. Supplemental Overcurrent

Protective Devices

Branch circuit overcurrent protective devices (OCPD) can be
used everywhere OCPD are used, from protection of motors
and motor circuits and group motor circuits, to protection of
distribution and utilization equipment. Supplemental OCPD
can only be used where proper protection is already being
provided by a branch circuit device, by exception [i.e.,
430.72(A)], or if protection is not required. Supplemental
OCPD can often be used to protect motor control circuits but
they cannot be used to protect motors or motor circuits. A very
common misapplication is the use of a supplementary 
overcurrent protective device such as a UL 1077 mechanical
overcurrent device for motor branch circuit short-circuit and
ground fault protection. Supplementary OCPDs are incomplete
in testing compared to devices that are evaluated for branch
circuit protection. THIS IS A SERIOUS MISAPPLICATION
AND SAFETY CONCERN!! Caution should be taken to assure
that the proper overcurrent protective device is being used for
the application at hand. Below is a description of popular 
supplementary overcurrent protective devices.

Most supplemental overcurrent protective devices have very
low interrupting ratings. Just as any other overcurrent
protective device, supplemental OCPDs must have an 
interrupting rating equal to or greater than the available 
short-circuit current.

Supplemental fuses as listed or recognized to the

UL/CSA/ANCE Trinational 248-14 Standard

These are fuses that can have many voltages and interrupting
ratings within the same case size. Examples of supplemental
fuses are 

13

32

'' X 1 

1

2

'', 5 x 20mm, and 

1

4

'' x 1 

1

4

'' fuses.

Interrupting ratings range from 35 to 100kA.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

523

Ser

vices &

A

pplication Guide

Application Guide

Motor Circuit Branch Circuit Protection

Motor Circuits – Choice of Overcurrent Protection

Motor circuits have unique characteristics and several 
functions, such as short-circuit protection, overload protection
and automatic/ remote start/stop, that may be required.
Sometimes the comment is made that users prefer circuit
breakers because they can be reset. Let’s examine the choice
of either circuit breakers or current- limiting fuses for motor
branch circuit protection.

In the case to be examined, fuses and circuit breakers
(includes magnetic only circuit breakers which are called
MCPs or motor circuit protectors) are sized with the intent to
provide only short-circuit and ground fault protection for the
motor branch circuit protection per 430.52. Other means, such
as overload relays, provide the motor overload protection.
Typical thermal magnetic circuit breakers can only be sized for
motor branch circuit protection (typically 200% - 250% of
motor current) because if they are sized closer, the motor
starting current trips the circuit breaker’s instantaneous 
mechanism. Magnetic only circuit breakers (MCPs) are 
intentionally not provided with overload capability; they only
operate on short-circuit currents. There are some fuses such
as the FRS-R and LPS-RK fuses that can be sized close
enough for motor running overload protection or backup motor
running protection. But for the discussion in this section,
assume current-limiting fuses are sized only for motor 
short-circuit and ground fault protection.

It is important to note that in this protection level being 
discussed, a circuit breaker or fuses should only open if there
is a fault on the motor circuit. A separate overload protective
device, such as an overload relays, provides motor overload
protection per 430.32. Here are some important 
considerations:

1. OSHA regulation 1910.334(b)(2) Use of Equipment states:

Reclosing circuits after protective device operation. After a circuit is
deenergized by a circuit protective device, the circuit may not be 
manually reenergized until it has been determined that the equipment
and circuit can be safely energized. The repetitive manual reclosing of
circuit breakers or reenergizing circuits through replaced fuses is 
prohibited. NOTE: When it can be determined from the design of the 
circuit and the over-current devices involved that the automatic 
operation of a device was caused by an overload rather than a fault 
condition, no examination of the circuit or connected equipment is 
needed before the circuit is reenergized.

So the speed of reclosing a circuit breaker after a fault is not an 
advantage. The law requires that if the condition is a fault (that is the
only reason the circuit breaker or fuses should open on a motor circuit),
then the fault must be corrected prior to replacing fuses or resetting the
circuit breaker.

2. The typical level of short-circuit protection for the motor starter provided

by circuit breakers and MCPs is referred to as Type 1. This is because
most circuit breakers are not current-limiting. So, for a loadside fault,
the starter may sustain significant damage such as severe welding of
contacts and rupturing of the heater elements. Or the heater/overload
relay system may lose calibration. This is an acceptable level of 
performance per UL 508, which is the product standard for motor
starters. Current-limiting fuses can be selected that can provide Type 2
“No Damage” short-circuit protection for motor starters.

Consequently, with circuit breaker protection, after a fault condition, 

significant downtime and cost may be incurred in repairing or replacing
the starter. With properly selected fuses for Type 2 protection, after the
fault is repaired, only new fuses need to be inserted in the circuit; the
starter does not have to be repaired or replaced.

3. Circuit breakers must be periodically tested to verify they mechanical

operate and electrically tested to verify they still are properly calibrated
within specification. The circuit breaker manufacturers recommend this.
Typically circuit breakers should be mechanically operated at least every
year and electrically tested every 1 to 5 years, depending on the service
conditions. Modern current-limiting fuses do not have to be maintained
or electrically tested to verify they still will operate as intended. The 
terminations of both circuit breakers and fusible devices need to be 
periodically checked and maintained to prevent thermal damage. Plus
fuse clips should be periodically inspected and if necessary maintained.

4. After a circuit breaker interrupts a fault, it may not be suitable for further

service. UL 489, the product standard for molded case circuit breakers,
only requires a circuit breaker to interrupt two short-circuit currents at
its interrupting rating. Circuit breakers that are rated 100 amps or less
do not have to operate after only one short-circuit operation under “bus
bar” short-circuit conditions. If the fault current is high, circuit breaker
manufacturers recommend that a circuit breaker should receive a 
thorough inspection with replacement, if necessary. How does one know
a circuit breaker’s service history or what level of fault current that a 
circuit breaker interrupts? With modern current-limiting fuses, if the fuse
interrupts a fault, new factory calibrated fuses are installed in the circuit.
The original level of superior short-circuit protection can be there for the
life of the motor circuit.

5. After a fault, the electrician has to walk back to the storeroom to get new

fuses; that is if spare fuses are not stored adjacent to the equipment.
This does require some additional down time. However, if fuses opened
under fault conditions, there is a fault condition that must be remedied.
The electrician probably will be going back to the storeroom anyway for
parts to repair the fault. If properly selected current-limiting fuses are
used in the original circuit, the starter will not sustain any significant
damage or loss of overload calibration.

With circuit breaker protection on motor circuits, after a fault
condition, it may be necessary to repair or replace the starter,
so a trip to the storeroom may be necessary. And if the starter
is not significantly damaged, it may still need to be tested to
insure the let-through energy by the circuit breaker has not
caused the loss of starter overload calibration. Also, the circuit
breaker needs to be evaluated for suitability before placing it
back into service. Who is qualified for that evaluation? How
much time will that take?

In summary, resettability is not an important feature for motor
branch circuit (short-circuit) protection and resettability of the
branch circuit protective device is not a benefit for motor 
circuits. As a matter of fact, resettability of the motor branch
circuit overcurrent protective device may encourage an unsafe
practice. The function of motor branch circuit protection is fault
protection: short-circuit and ground fault protection. Faults do
not occur on a regular basis. But when a fault does occur, it is
important to have the very best protection. The best motor
branch circuit protection can be judged by (1) reliability - its
ability to retain its calibration and speed of operation over its
lifetime, (2) current-limiting protection - its ability to provide
Type 2 “No Damage” protection to the motor starter, and (3)
safety - its ability to meet a facility’s safety needs. Modern 
current-limiting fuses are superior to circuit breakers for motor
branch circuit protection.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

524

Application Guide

Glossary

Ampere (Amp)

The measurement of intensity of rate of
flow of electrons in an electric circuit. An
ampere (amp) is the amount of current
that will flow through a resistance of one
ohm under a pressure of one volt.
Ampere is often abbreviated as “A.”

Amp Rating

The current-carrying capacity of a fuse.
When a fuse is subjected to a current
above its amp rating, it will open the 
circuit after a predetermined period of
time.

Amp Squared Seconds, l

2

t

The measure of heat energy developed
within a circuit during the fuse’s 
clearing. It can be expressed as 
“melting l

2

t”, “arcing l

2

t” or the sum of

them as “Clearing l

2

t”. “l” stands for

effective let-through current (RMS),
which is squared, and “t” stands for time
of opening, in seconds.

Arcing I

2

t

Value of the I

2

t during the arcing time

under specified conditions.

Arcing Time

The amount of time from the instant 
the fuse link has melted until the 
overcurrent is interrupted, or cleared.

Breaking Capacity

(See Interrupting Rating)

Cartridge Fuse

A fuse consisting of a current 
responsive element inside a fuse tube
with terminals on both ends.

Class CC Fuses

600V, 200kA interrupting rating, branch
circuit fuses with overall dimensions of

13

32

” x 1

1

2

”. Their design incorporates a

rejection feature that allows them to be
inserted into rejection fuse holders and
fuse blocks that reject all lower voltage,
lower interrupting rat ing 

13

32

” x 1

1

2

” fuses.

They are available from 

1

10

A through

30A.

Class G Fuses

480V, 100kA interrupting rating branch
circuit fuses that are size rejecting to
eliminate overfusing. The fuse diameter
is 

13

32

˝ while the length varies from 1

5

16

˝

to 2

1

4

˝. These are available in ratings

from 1A through 60A.

Class H Fuses

250V and 600V, 10kA interrupting rating
branch circuit fuses that may be 
renewable or non-renewable. These are
available in amp ratings of 1A through
600A.

Class J Fuses

These fuses are rated to interrupt a 
minimum of 200kA AC. They are labeled
as “Current-Limiting,” are rated for
600Vac, and are not interchangeable
with other classes.

Class K Fuses

These are fuses listed as K-1, K-5, or 
K-9 fuses. Each subclass has 
designated I

2

t and lp maximums. These

are dimensionally the same as Class H
fuses, and they can have interrupting
ratings of 50kA, 100kA, or 200kA.
These fuses are current-limiting.
However, they are not marked 
“current-limiting” on their label since
they do not have a rejection feature.

Class L Fuses

These fuses are rated for 601 through
6000A, and are rated to interrupt a 
minimum of 200kA AC. They are labeled
“Current-Limiting” and are rated for
600Vac. They are intended to be bolted
into their mountings and are not 
normally used in clips. Some Class L
fuses have designed in time-delay 
features for all purpose use.

Class R Fuses

These are high performance fuses rated

1

10

-600A in 250V and 600V ratings. All

are marked “Current Limiting” on their
label and all have a minimum of 200kA
interrupting rating. They have identical
outline dimensions with the Class H
fuses but have a rejection feature which
prevents the user from mounting a fuse
of lesser capabilities (lower interrupting
capacity) when used with special Class
R Clips. Class R fuses will fit into either
rejection or non-rejection clips.

Class T Fuses

An industry class of fuses in 300V and
600V ratings from 1A through 1200A.
They are physically very small and can
be applied where space is at a 
premium. They are fast-acting fuses
with an interrupting rating of 200kA
RMS.

Classes of Fuses

The industry has developed basic 
physical specifications and electrical
performance requirements for fuses with
voltage ratings of 600V or less. These
are known as standards. If a type of
fuse meets the requirements of a 
standard, it can fall into that class.
Typical classes are K, RK1, RK5, G, L,
H, T, CC, and J.

Clearing Time

The total time between the beginning of
the overcurrent and the final opening of
the circuit at rated voltage by an 
overcurrent protective device. Clearing
time is the total of the melting time and
the arcing time.

Current Limitation

A fuse operation relating to short circuits
only. When a fuse operates in its 
current-limiting range, it will clear a short
circuit in less than 

1

2

cycle. Also, it will

limit the instantaneous peak let-through
current to a value substantially less than
that obtainable in the same circuit if that
fuse were replaced with a solid 
conductor of equal impedance.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

525

Ser

vices &

A

pplication Guide

Application Guide

Glossary

Dual Element Fuse

Fuse with a special design that utilizes
two individual elements in series inside
the fuse tube. One element, the spring
actuated trigger assembly, operates on
overloads up to 5-6 times the fuse 
current rating. The other element, the
short circuit section, operates on short
circuits up to their interrupting rating.

Electrical Load

That part of the electrical system which
actually uses the energy or does the
work required.

Fast-Acting Fuse

A fuse which opens on overload and
short  circuits very quickly. This type of
fuse is not designed to withstand 
temporary overload  currents associated
with some electrical loads.

Fuse

An overcurrent protective device with a
fusible link that operates and opens the
circuit on an overcurrent condition.

High Speed Fuses

Fuses with no intentional time-delay in
the overload range and designed to
open as quickly as possible in the 
short-circuit range. These fuses are
often used to protect solid-state devices.

Inductive Load

An electrical load which pulls a large
amount of current—an inrush current—
when first energized. After a few cycles
or seconds the current “settles down” to
the full-load running current.

Interrupting Capacity

(See Interrupting Rating)

Interrupting Rating — IR

(Breaking Capacity)

The rating which defines a fuse’s ability
to  

safely

interrupt and clear short 

circuits. This rating is much greater than
the ampere rating of a fuse. The NEC

®

defines Interrupting Rating as “The 
highest current at rated voltage that an
 overcurrent protective device is intend-
ed to interrupt under standard test 
conditions.”

Melting I

2

t

Value of the I

2

t during the melting time

of the fuse link under specified 
conditions.

Melting Time

The amount of time required to melt the
fuse link during a specified overcurrent.
(See Arcing Time and Clearing Time.)

“NEC

®

” Dimensions

These are dimensions once referenced
in the National Electrical Code. They are
common to Class H and K fuses and
provide interchangeability between 
manufacturers for fuses and fusible
equipment of given ampere and 
voltage ratings.

Ohm

The unit of measure for electric 
resistance. An ohm is the amount of
resistance that will allow one ampere to
flow under a pressure of one volt.

Ohm’s Law

The relationship between voltage, 
current, and resistance, expressed by
the equation E = IR, where E is the 
voltage in volts, I is the current in amps,
and R is the resistance in ohms.

One Time Fuses

Generic term used to describe a Class
H non-renewable cartridge fuse, with a
single element.

Overcurrent

A condition which exists on an electrical
 circuit when the normal load current is
exceeded. Overcurrents take on two
separate characteristics—overloads and
short-circuits.

Overload

Can be classified as an overcurrent
which exceeds the normal full load 
current of a circuit. Also characteristic of
this type of overcurrent is that it does
not leave the normal current carrying
path of the circuit—that is, it flows from
the source, through the conductors,
through the load, back through the 
conductors, to the source again.

Peak Let-Through Current, lp

The instantaneous value of peak current
let-through by a current-limiting fuse,
when it operates in its current-limiting
range.

Renewable Fuse (600V & below)

A fuse in which the element, typically a
zinc link, may be replaced after the fuse
has opened, and then reused. Renewable
fuses are made to Class H standards.

Resistive Load

An electrical load which is characteristic of
not having any significant inrush current.
When a resistive load is energized, the
current rises instantly to its steady-state
value, without first rising to a higher value.

RMS Current

The RMS (root-mean-square) value of
any periodic current is equal to the value
of the direct current which, flowing through
a resistance, produces the same heating
effect in the resistance as the periodic 
current does.

SCCR

See Short-Circuit Current Rating

Semiconductor Fuses

Fuses used to protect solid-state devices.
See “High Speed Fuses.”

Short-Circuit

Can be classified as an overcurrent which
exceeds the normal full load current of a
circuit by a factor many times (tens, 
hundreds or thousands greater). Also
characteristic of this type of overcurrent is
that it leaves the normal current carrying
path of the circuit—it takes a “short cut”
around the load and back to the source.

Short-Circuit Current Rating 
(SCCR)

The maximum short-circuit current an
electrical component can sustain without
the occurrence of excessive damage
when protected with an overcurrent 
protective device.

Short-Circuit Withstand Rating

Same definition as short-circuit current
rating.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

526

Application Guide

Glossary

Single-Phasing

That condition which occurs when one-
phase of a three-phase system opens,
either in a low voltage (secondary) or
high voltage (primary) distribution 
system. Primary or secondary single-
phasing can be caused by any number
of events. This condition results in
unbalanced currents in polyphase
motors and unless protective measures
are taken, causes overheating and 
failure.

Threshold Current

The symmetrical RMS available current
at the threshold of the current-limiting
range, where the fuse becomes 
current-limiting when tested to the
industry standard. This value can be
read off of a peak let-through chart
where the fuse curve intersects the A-B
line. A threshold ratio is the relationship
of the threshold current to the fuse’s
continuous current rating.

Time-Delay Fuse

A fuse with a built-in delay that allows
temporary and harmless inrush currents
to pass without opening, but is so
designed to open on sustained 
overloads and short circuits.

Total Clearing I

2

t

Total measure of heat energy developed
within a circuit during the fuse’s clearing
of a fault current. Total Clearing I

2

t is the

sum of the melting I

2

t and arcing I

2

t.

Voltage Rating

The maximum open circuit voltage in
which a fuse can be used, yet safely
interrupt an overcurrent. Exceeding the
voltage rating of a fuse impairs its ability
to clear an overload or short-circuit 
safely.

Withstand Rating

The maximum current that an 
unprotected electrical component can
sustain for a specified period of time
without the occurrence of extensive
damage.

Bussmann #             Upgrade #                                     Description                                       Data Sheet #

AGC-(AMP)         ABC-(AMP)                FAST-ACTING, 

1

4

” X 1

1

4

” FUSE                               2001

AGC-V-(AMP)     ABC-V-(AMP)             FAST-ACTING, 

1

4

” X 1

1

4

” FUSE WITH LEADS         2001

AGU-(AMP)         LP-CC-(AMP)             FAST-ACTING, 

13

32

” X 1

1

2

” FUSE                             2008

BAF-(AMP)         LP-CC-(AMP)             FAST-ACTING, 

13

32

” X 1

1

2

” FUSE                             2011

BAN-(AMP)         LP-CC-(AMP)             FAST-ACTING, 

13

32

” X 1

1

2

” FUSE                             2046

DCM-(AMP)       PVM-(AMP)               SOLAR USE - FAST-ACTING, 

13

32

” X 1

1

2

” FUSE      2153

DCM-(AMP)       KLM-(AMP)               INDUSTRIAL - FAST-ACTING, 

13

32

” X 1

1

2

” FUSE     2020

DLS-(AMP)         ECNR-(AMP)               TIME-DELAY, 250Vac, CLASS RK5                             1315

DLS-(AMP)           ECSR-(AMP)               TIME-DELAY, 600Vac, CLASS RK5                             1318

FNM-(AMP)        LP-CC-(AMP)             TIME-DELAY, 

13

32

” X 1

1

2

” FUSE                               2028

FNQ-R-(AMP)     LP-CC-(AMP)*           TIME-DELAY, 500V, 

13

32

” X 1

1

2

” FUSE                     1012

FNR-R-(AMP)     LPN-RK-(AMP)SP     TIME-DELAY, 250V, CLASS RK5 FUSES               1019/1020

FRS-R-(AMP)     LPS-RK-(AMP)SP     TIME-DELAY, 600V, CLASS RK5 FUSES               1017/1018

JKS-(AMP)         LPJ-(AMP)SP             FAST-ACTING, 600V, CLASS J FUSE                     1026/1027

KLU-(AMP)         KRP-C-(AMP)SP       TIME-DELAY, CLASS L FUSE                                 1013

KTK-(AMP)         KTK-R-(AMP)             FAST-ACTING, 600V, 

13

32

” X 1

1

2

” FUSE                   1011

KTK-R-(AMP)     LP-CC-(AMP)             FAST-ACTING, 600V, CLASS CC FUSE                  1015

KTN-R-(AMP)     LPN-RK-(AMP)SP     FAST-ACTING, 250V, CLASS RK1 FUSE                1043

KTS-R-(AMP)     LPS-RK-(AMP)SP     FAST-ACTING, 600V, CLASS RK1 FUSE                1044

KTU-(AMP)         KPR-C-(AMP)SP       FAST-ACTING, 600V, CLASS L FUSE                     1010

KWS-R-(AMP)    LPS-RK-(AMP)SP     FAST-ACTING, 600V, CLASS RK1 FUSE                1044

MDL-(AMP)        MDA-(AMP)               TIME-DELAY, 

1

4

” X 1

1

4

” FUSE                                 2004

MDL-V-(AMP)     MDA-V-(AMP)           TIME-DELAY, 

1

4

” X 1

1

4

” FUSE WITH LEADS           2004

MTH-(AMP)        ABC-(AMP)                FAST-ACTING, 

1

4

” X 1

1

4

” FUSE

NON-(AMP)        LPN-RK-(AMP)SP     GENERAL PURPOSE, 250V, CLASS H FUSES       1030

NOS-(AMP)         LPS-RK-(AMP)SP     GENERAL PURPOSE, 600V, CLASS H FUSES       1030

REN-(AMP)         LPN-RK-(AMP)SP     250V RENEWABLE FUSELINK                               1028

RES-(AMP)         LPS-RK-(AMP)SP     600V RENEWABLE FUSELINK                               1028

SL-(AMP)           S-(AMP)                     TIME-DELAY, 125V, PLUG FUSE                           1033

TL-(AMP)           T-(AMP)                     TIME-DELAY, 125V, PLUG FUSE                           1035

W-(AMP)             TL-(AMP)                   TIME-DELAY, 125V, PLUG FUSE                           1035

Out-of-Stock

Substitution/Upgrades

*Not recommended for control transformer circuits.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

527

Ser

vices &

A

pplication Guide

Application Guide

527

Industrial Fuse Applications

Industrial Applications

1. Interior Lighting

2. Computer Power

3. Switchboards

4. Motor Control Center

5. Emergency Lighting

6. UPS Backup Power Supplies

7. Transformer/Emergency Generator

8. Forklift Battery Charging Station

9. HVAC Chillers/Blowers

10. Welding Circuits

11. Plant Lighting

12. Distribution Panels

13. Disconnect Switches

14. Programmable Logic Circuits

15. Conveyor System

Commercial Applications

1. Interior Lighting

2. HVAC Blowers

3. Computer Power

4. Branch Circuits

5. Emergency Lighting

6. Load Centers

7. Disconnect/Distribution Panels

8. HVAC/Chillers

9. Switchboards/Motor Control Centers

10. UPS Backup Power Supplies

11. Elevator Control Centers

12. Transformer/Emergency Generator

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

528

FUSEFinder Quick Cross Reference Guide

Competitor
Fuse Family

Bussmann

Competitor
Fuse Family

Competitor
Fuse Family

Bussmann

Bussmann

Bussmann, the industry leader in critical circuit protection, power management and electrical safety offers an 
extensive selection of fuses and fuse blocks to meet precise overcurrent protection needs.

Whether it’s glass tube, low voltage or high speed fuse ... or fuse blocks needed for an application, you can use 
this FuseFinder Quick Cross Reference Guide to fi nd the Bussmann replacement. If you cannot fi nd a cross, 
more extensive listings are available online at 

www.cooperbussmann.com/FuseFinder

. Or contact our Application 

Engineers at 

FuseTech@cooperindustries.com

.

GMT-(AMP)A

GDC-(AMP)

GDB-(AMP)

GDC-(AMP)

S505-(AMP)

GDA-(AMP)

GDB-(AMP)

GDC-(AMP)

S505-V-(AMP)

GDA-V-(AMP)

GDB-V-(AMP)

GDC-V-(AMP)

BK/C515-(AMP)

GMA-(AMP)

GMA-V-(AMP)

GMD-V-(AMP)

GMD-(AMP)

MCRW-(AMP)

MCRW-(AMP)

MCRW-(AMP)

MCRW-(AMP)

ATC-(AMP)

MCRW-(AMP)

MCRW-(AMP)

ATM-(AMP)

MAX-(AMP)

BK/C517-(AMP)

BK/C515-(AMP)

AGA-(AMP)

AGW-(AMP)

SFE-(AMP)

AGC-(AMP)

AGC-(AMP)

MDL-(AMP)

ABC-(AMP)

MDL-V-(AMP)

AGC-V-(AMP)

GBB-(AMP)

MDA-(AMP)

ABC-V-(AMP)

MDA-V-(AMP)

MDA-(AMP)

GLD-(AMP)

GBA-(AMP)

AGX-(AMP)

AGX-(AMP)

SL-(AMP)

S-(AMP)

T-(AMP)

ABC-(AMP)

AGC-V-(AMP)

AGC-(AMP)

AGC-(AMP)

AGC-(AMP)

MDL-(AMP)

MDL-V-(AMP)

AGC-V-(AMP)

MDL-(AMP)

MDL-V-(AMP)

GMT-(AMP)A

ABS-(AMP)

ABS-(AMP)

413(AMP)

414(AMP)

417(AMP)

418(AMP)

429(AMP)

431(AMP)

5140(AMP)

5170(AMP)

523(AMP)

5HF(AMP)

5HFP(AMP)

5HT(AMP)

5MF(AMP)

5MFP(AMP)

5SF(AMP)

5ST(AMP)

6J(AMP)X

6R(AMP)D

702(AMP)

703(AMP)

81200(AMP)ST

A70P(AMP)-1 or Type 1

A70P(AMP)-4 or Type 4

A70Q(AMP)-4 or Type 4

A70QS(AMP)-14F

A70QS(AMP)-22F

A70QS[35-200]-4

A70QS[225-400]-4 or 4K

A70QS[450-600]-4K

A70QS[700-800]-4

A50P(AMP)-1

A50P(AMP)-4

A50QS(AMP)-4 or Type 4

A30QS(AMP)-1 or Type 1

A30QS[35-700]-4 or Type 4

A30QS[1000-1200]-128

A15QS[1-30]-2

A15QS[35-60]-1

A15QS[70-400]-4

A2D(AMP)R

A2K(AMP)

A3T(AMP)

A4BQ[225-600]

A4BQ[601-6000]

A4BT[601-4000]

A4BY(AMP)

A4J(AMP)

A6D(AMP)R

A6K(AMP)

A6T(AMP)

AG(AMP)

AJT(AMP)

AM10/(AMP)

AOK(AMP)

ATDR(AMP)

ATM(AMP)

ATMR(AMP)

ATQ(AMP)

ATQR(AMP)

BBC(AMP)

BDB(AMP)

BDC(AMP)

MDM-(AMP)

ABS-(AMP)

ABS-(AMP)

TR/3216FF-(AMP)

3216FF(AMP)

0603FA(AMP)

BAF-(AMP)

AGU-(AMP)

FNM-(AMP)

GDA-(AMP)

GDA-V-(AMP)

BK/S505-(AMP)A

GMA-(AMP)

GMA-V-(AMP)

GDB-(AMP)

GDC-(AMP)

KTK-(AMP)

LPS-RK-(AMP)SP

HVJ-(AMP)

HVL-(AMP)

CBS-(AMP)

FWP-(AMP)A14F

FWP-(AMP)A orB

FWP-(AMP)A or B

FWP-(AMP)A14F

FWP-(AMP)A22F

FWP-(AMP)A or B

FWP-(AMP)A or B

FWP-(AMP)A or B

FWP-(AMP)A or B

FWH-(AMP)A14F

FWH-(AMP)A or B

FWH-(AMP)A or B

FWX-(AMP)A14F

FWX-(AMP)A

FWX-(AMP)AH

FWA-(AMP)A10F

FWA-(AMP)A21F

FWA-(AMP)B

LPN-RK(AMP)SP

KTN-R(AMP)

JJN(AMP)

KRP-CL-(AMP)

KRP-C-(AMP)SP

KLU[601-4000]

KLU(AMP)

JKS(AMP)

LPS-RK(AMP)SP

KTS-R(AMP)

JJS(AMP)

SC(AMP)

LPJ(AMP)SP

LP-CC-(AMP)

ALS-(AMP)

LP-CC-(AMP)

KLM(AMP)

KTK-R(AMP)

FNQ-(AMP)

FNQ-R-(AMP)

ABC-(AMP)

GDB-(AMP)

GDC-(AMP)

BDL(AMP)

BGC(AMP)

BGX(AMP)

BLF(AMP)

BLN(AMP)

BLS(AMP)

BMA(AMP)

CBO(AMP)  [4-160A]

CCK(AMP)  [1-300A]

CCL(AMP)  [30-100A]

CCLB(AMP)  [20-250A]

CCLW(AMP)  [1-300A]

CCMR[1-30A Only]

CDNC(AMP)

CDSC(AMP)

CNL(AMP)

CNN(AMP)

DCT[1-15A]

E(AMP)FC

E(AMP)FE

E(AMP)FET

E(AMP)FM

E(AMP)FMM

E(AMP)LCT  [6-20A]

E(AMP)LET  [25-180A]

E(AMP)LMMT  [315-900A]

E(AMP)LMT  [160-450A]

E100SF(AMP)  [20-30A]

E100S(AMP)  [40-2000A]

E15S(AMP)  [35-3000A]
E15SF(AMP)  [5, 10, 15, 20, 25, 30A]

E25S(AMP)  [1000-2500A]

E25S(AMP)  [35-800A]

E25SFX(AMP)  [5-30A]

E50S(AMP)

E50SF(AMP)  [5-30A]

E70S(AMP)

ECK(AMP)  [1-300A]

ECL(AMP)  [30-100A]

ECN(AMP)

ECNR(AMP)

ECS(AMP)

ECSR(AMP)

ELR(AMP)

ENLE(AMP)

ENNE(AMP)

ERN(AMP)

ERS(AMP)

ESA(AMP)

FA(AMP)

FII(AMP)

FIIC(AMP)

FIIM(AMP)  [125-200A]

FIIM(AMP)  [80-100A]

FLA(AMP)

FLM(AMP)

FLN(AMP)

FLNR(AMP)

FLQ(AMP)

FLS(AMP)

FLSR(AMP)

GFN(AMP)

MDL-(AMP)

AGC-(AMP)

AGX-(AMP)

BAF-(AMP)

BAN-(AMP)

BBS-(AMP)

GDA-(AMP)

HBO-(AMP)

ACK-(AMP)

ACL-(AMP)

KGJ-E-(AMP)

KGJ-(AMP)

LP-CC(AMP)

CDN(AMP)

CDS(AMP)

ANL-(AMP)

ANN-(AMP)

PV-(AMP)A10F

(AMP)FC

(AMP)FE

(AMP)FET

(AMP)FM

(AMP)FMM

(AMP)LCT

(AMP)LET

(AMP)LMMT

(AMP)LMT

FWJ-(AMP)A14F

FWJ-(AMP)

FWA-(AMP)A

FWA-(AMP)A10F

FWX-(AMP)AH

FWX-(AMP)A

FWX-(AMP)14F

FWH-(AMP)

FWH-(AMP)14F

FWP-(AMP)

ACK-(AMP)

ACL-(AMP)

FRN-R-(AMP)

FRN-R-(AMP)

FRS-R-(AMP)

FRS-R-(AMP)

GLR-(AMP)

ANL-(AMP)

ANN-(AMP)

REN-(AMP)

RES-(AMP)

S-(AMP)

SA(AMP)

CGL-(AMP)

CGL-(AMP)

(AMP)M14CB

(AMP)L09CB

FNA-(AMP)

FNM-(AMP)

FRN-R-(AMP)

FRN-R-(AMP)

FNQ-(AMP)

FRS-R-(AMP)

FRS-R-(AMP)

FNA-(AMP)

0481(AMP)

211(AMP)

212(AMP)

213(AMP)

215(AMP)

216(AMP)

217(AMP)

218(AMP)

221(AMP)

226(AMP)

227(AMP)

228(AMP)

230(AMP)

235(AMP)

236(AMP)

238(AMP)

239(AMP)

251(AMP)

252(AMP)

255(AMP)  [1/16-5A]

256(AMP)

257(AMP)

275(AMP)

276(AMP)
297(AMP)[AUTOMOTIVEFUSE]

299(AMP)

2AG220

2AG230

301(AMP)

303(AMP)

307(AMP)

311(AMP)

312(AMP)

313(AMP)

314(AMP)

315(AMP)

318(AMP)

322(AMP)

323(AMP)

324(AMP)

325(AMP)

326(AMP)

334(AMP)

336(AMP)

361(AMP)

362(AMP)

3770(AMP)

3780(AMP)

3785(AMP)

3AB(AMP)

3ABP(AMP)

3AG(AMP)

3AG311(AMP)

3AG312(AMP)

3AG313(AMP)

3AG315(AMP)

3AG318(AMP)

3SB(AMP)

3SBP(AMP)

401(AMP)

411(AMP)

412(AMP)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

529

FUSEFinder Quick Cross Reference Guide

Inde

x b
y

P

ar

t Number

GGU(AMP)

GL10/(AMP)

HCLR(AMP)

HCTR(AMP)

HSJ(AMP)

IDSR[6-60A Only]

J(AMP)

JDL(AMP)

JFL(AMP)

JLLN(AMP)

JLLS(AMP)

JLS(AMP)

JTD(AMP)

KLA(AMP)  [5, 10, 15, 20, 25, 30A]

KLB(AMP)  [1-30A]

KLC(AMP)

KLDR (AMP)

KLH(AMP)  [1-30A]

KLH(AMP)  [225-600A]

KLH(AMP)  [35-200A]

KLK(AMP)

KLKR(AMP)

KLLU(AMP)

KLMR(AMP)

KLNR(AMP)

KLPC(AMP)

KLSR(AMP)

KLW(AMP)

KON(AMP)

KOS(AMP)

L(AMP)TD

L15S(AMP)  [1-30A]

L15S(AMP)  [35-60A]

L15S(AMP)  [70-400A]

L25S(AMP)  [1-30A]

L50S(AMP)  [1-30A]

L70S(AMP)  [1-30A]

LCU(AMP)

LEN(AMP)

LENRK(AMP)

LES(AMP)

LESR(AMP)

LESRK(AMP)

LGR(AMP)

LHR(AMP)

LKU(AMP)

LLNRK(AMP)

LLSRK(AMP)

MEN(AMP)

MEQ(AMP)

MJS(AMP)

MOL(AMP)

MQ(AMP)

NCL(AMP)

NCLR(AMP)

NLN(AMP)

NLS(AMP)

OT(AMP)

OTM(AMP)

OTS(AMP)

PICO

R224(AMP)

R230(AMP)

R251(AMP)T1

AGU(AMP)

KTK-(AMP)

KTK-R-(AMP)

FNQ-R-(AMP)

DFJ(AMP)

FRS-R-(AMP)ID

JKS-(AMP)

LPJ-(AMP)SP

JKS-(AMP)

JJN-(AMP)

JJS-(AMP)

JKS-(AMP)

LPJ-(AMP)SP

FWA-(AMP)A10F

FWX-(AMP)A14F

KAC-(AMP)

FNQ-R-(AMP)

FWH-(AMP)A14F

FWH-(AMP)A

FWH-(AMP)B

KTK-(AMP)

KTK-R-(AMP)

KLU-(AMP)

LP-CC-(AMP)

KTN-R-(AMP)

KRP-C-(AMP)SP

KTS-R-(AMP)

FWA-(AMP)10F

NON-(AMP)

NOS-(AMP)

KRP-C-(AMP)SP

FWA-(AMP)A10F

FWA-(AMP)A21F

FWA-(AMP)A

FWX-(AMP)A14F

FWH-(AMP)A14F

FWP-(AMP)A14F

KTU-(AMP)

FRN-R-(AMP)

LPN-RK-(AMP)SP

FRS-R-(AMP)

FRS-R-(AMP)

LPS-RK-(AMP)SP

GLR-(AMP)

HLR(AMP)

KLU-(AMP)

LPN-RK-(AMP)SP

LPS-RK-(AMP)SP

FNM-(AMP)

FNQ-(AMP)

BK/C515-(AMP)

BAF-(AMP)

MCRW-(AMP)

KTN-R-(AMP)

KTN-R-(AMP)

NON-(AMP)

NOS-(AMP)

NON(AMP)

BAF-(AMP)

NOS(AMP)

MCRW-(AMP)

TR2/C518-(AMP)A

TR/C515-(AMP)A

TR/MCRW-(AMP)

RF(AMP)

RFS(AMP)

RLN(AMP)

RLS(AMP)

SAO(AMP)

SBS(AMP)

SCL(AMP)

SCLR(AMP)

SEC(AMP)

SLC(AMP)

SLO(AMP)

SOO(AMP)

TLO(AMP)

TOO(AMP)

TR(AMP)

TRM(AMP)

TRS(AMP)

WOO(AMP)

LFJ60030(X) / (X)ID

LFJ60060(X) / (X)ID

LFJ60100(X) / (X)ID

LFJ60200(X) / (X)ID

LFJ60400(X) / (X)ID

LFJ60600(X) / (X)ID

LFR25030(X) / (X)ID

LFR25060(X) / (X)ID

LFR25100(X) / (X)ID

LFR25200(X) / (X)ID

LFR25400(X) / (X)ID

LFR25600(X) / (X)ID

LFR60030(X) / (X)ID

LFR60060(X) / (X)ID

LFR60100(X) / (X)ID

LFR60200(X) / (X)ID

LFR60400(X) / (X)ID

LFR60600(X) / (X)ID

LFH25030(X) / (X)ID

LFH25060(X) / (X)ID

LFH25100(X) / (X)ID

LFH25200(X) / (X)ID

LFH25400(X) / (X)ID

LFH25600(X) / (X)ID

LFH60030(X) / (X)ID

LFH60060(X) / (X)ID

LFH60100(X) / (X)ID

LFH60200(X) / (X)ID

LFH60400(X) / (X)ID

LFH60600(X) / (X)ID

LFPSJ30(X) / (X)ID

LFPSJ60(X) / (X)ID

LPHV

LPSC00(X) / (X)ID

LPSM00(X) / (X)ID

6030(X)J

6060(X)J

610(XX)J

620(XX)J

640(XX)J

66(XX)J

203(XX)

206(XX)

210(XX)

220(XX)

240(XX)

26(XX)

603(XX)

606(XX)

610(XX)

620(XX)

640(XX)

66(XX)

203(XX)R

206(XX)R

210(XX)R

220(XX)R

240(XX)R

26(XX)R

603(XX)R

606(XX)R

610(XX)R

620(XX)R

640(XX)R

66(XX)R

US3J(X) / (X)I

US6J(X) / (X)I

USPV

USCC(X) / (X)I

USM(X) / (X)I

(R)6J30A(X)S

(R)6J60A(X)B

R6J100A(X)B

6J200A(X)BFBD

6J400A(X)BFBD

6J600A(X)BFBD

R30A(X)(XX)

R60A(X)(XX)

R100A(X)B

R200A(X)BE

R400A(X)B

R600A(X)B

6R30A(X)(XX)

6R60A(X)(XX)

6R100A(X)B

6R200A(X)BE

6R400A(X)B

6R600A(X)B

(R)F30A(X)(XX)

(R)F60A(X)(XX)

RF100A(X)B

F200A(X)BE

RF400A(X)B

F600A(X)B

(R)6F30A(X)(XX)

(R)6F60A(X)(XX)

R6F100A(X)B

6F200A(X)BE

R6F400A(X)B

6F600A(X)B

6SJ30A(X) / (X)I

6SJ60A(X) / (X)I

6SC30A(X)-C / (X)I-C

6SM30A(X)-C / (X)I-C

REN(AMP)

RES(AMP)

REN-(AMP)

RES(AMP)

SA-(AMP)

BBS-(AMP)

KTS-R-(AMP)

KTS-R-(AMP)

SC-(AMP)

SC-(AMP)

SL-(AMP)

S-(AMP)

TL-(AMP)

T-(AMP)

FRN-R-(AMP)

FNM-(AMP)

FRS-R(AMP)

W-(AMP)

J60030-(X)CR*

J60060-(X)CR*

JM60100-(X)CR**

JM60200-(X)CR**

JM60400-(X)CR**

JM60600-(X)CR**

R25030-(X)CR*

R25060-(X)CR*

RM25100-(X)CR**

RM25200-(X)CR**

RM25400-(X)CR**

RM25600-(X)CR**

R60030-(X)CR*

R60060-(X)CR*

RM60100-(X)CR**

RM60200-(X)CR**

RM60400-(X)CR**

RM60600-(X)CR**

H25030-(X)CR*

H25060-(X)CR*

HM25100-(X)CR**

HM25200-(X)CR**

HM25400-(X)CR**

HM25600-(X)CR**

H60030-(X)CR*

H60060-(X)CR*

HM60100-(X)CR**

HM60200-(X)CR**

HM60400-(X)CR**

HM60600-(X)CR**

CH30J(X) / (X)I

CH60J(X) / (X)I

CHPV

CHCC(X)DU / (X)DIU
CHM(X)DU / CHM(X)DIU

J60030-(X)CR*

J60060-(X)CR*

JM60100-(X)CR**

JM60200-(X)CR**

JM60400-(X)CR**

JM60600-(X)CR**

H25030-(X)CR*

H25060-(X)CR*

HM25100-(X)CR**

HM25200-(X)CR**

HM25400-(X)CR**

HM25600-(X)CR**

H60030-(X)CR*

H60060-(X)CR*

HM60100-(X)CR**

HM60200-(X)CR**

HM60400-(X)CR**

HM60600-(X)CR**

R25030-(X)CR*

R25060-(X)CR*

RM25100-(X)CR**

RM25200-(X)CR**

RM25400-(X)CR**

RM25600-(X)CR**

R60030-(X)CR*

R60060-(X)CR*

RM60100-(X)CR**

RM60200-(X)CR**

RM60400-(X)CR**

RM60600-(X)CR**

CH30J(X) / (X)I

CH60J(X) / (X)I

CHPV

CHCC(X)DU / (X)DIU

CHM(X)DU / CHM(X)DIU

J60030-(X)CR*

J60060-(X)CR*

JM60100-(X)CR**

JM60200-(X)CR**

JM60400-(X)CR**

JM60600-(X)CR**

R25030-(X)CR*

R25060-(X)CR*

RM25100-(X)CR**

RM25200-(X)CR**

RM25400-(X)CR**

RM25600-(X)CR**

R60030-(X)CR*

R60060-(X)CR*

RM60100-(X)CR**

RM60200-(X)CR**

RM60400-(X)CR**

RM60600-(X)CR**

H25030-(X)CR*

H25060-(X)CR*

HM25100-(X)CR**

HM25200-(X)CR**

HM25400-(X)CR**

HM25600-(X)CR**

H60030-(X)CR*

H60060-(X)CR*

HM60100-(X)CR**

HM60200-(X)CR**

HM60400-(X)CR**

HM60600-(X)CR**

CH30J(X) / (X)I

CH60J(X) / (X)I

CHCC(X)DU / (X)DIU

CHM(X)DU / CHM(X)DIU

Data Sheets are available online at 

www.cooperbussmann.com/DatasheetsEle

.  For technical assistance, contact the Bussmann Application Engineering 

Team. Call 636-527-1270 between 8:00 AM and 5:00 PM Central Time, or e-mail 

FuseTech@cooperindustries.com

.

For customer assistance, call the Customer Satisfaction Team toll-free 855-BUSSMANN (855-287-7626) or e-mail 

BussCustSat@cooperindustries

.com

.

Competitor
Fuse Family

Bussmann

Competitor
Fuse Family

Competitor
Fuse Blocks 

1, 2, 3

Bussmann

Bussmann

Competitor
Fuse Blocks 

1, 2, 3

Bussmann

*

 

These

 B

ussmann

 

fuse

 

blocks

 

do

 

not

 

offer

 

indication

 

at

 

this

 

amperage,

 

however

 

a

 

SAMI

   

cover

 

can

 

be

 

used

 

to

 

offer

 

protection

 

against

 

accidental

 

contact

 

and

 

open

 

fuse

   

indication.

**

 

Finger-safe

 

covers

 

are

 

available

 

for

 

this

 

block

 

along

 

with

 

optional

 

open

 

fuse

 

indication.

1.

 

Some

 

competitor

 

blocks

 

are

 

adder

 

blocks

 

and/or

 

have

 

multiple

 

terminal

 

offerings

 

for

 

    

Cu/Al

 

or

 

Cu

 

only

 

conductors.

 B

ussmann

 

blocks

 

are

 

not

 

adder

 

blocks

 

below

 

100A,

  

    

and

 

all

 

blocks

 

are

 

tin

 

plated

 

aluminum

 

terminals

 

to

 

accommodate

 

both

 

Cu

 

and

    

Al

 

conductors.

2.

 

Wire

 

ranges

 

are

 

not

 

always

 

the

 

same.

 

Please

 

assure

 

wire

 

range

 

is

 

suitable

    

for

 

the

 

application.

3.

 

All

 

blocks

 

listed

 

have

 

a

 

box

 

lug

 

for

 

wire

 

termination.

 

Alternate

 

connection

 

    

types

 

are

 

available

 

in

 

the

 

30

 

and

 

60

 

amp

 

range.

 

If

 

an

 

alternate

 

type

 

is

 

    

required,

 

please

 

see

 

the

 

appropriate

 B

ussmann

 

data

 

sheet

 

for

 

part

 

number

 

    

ordering

 

information.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/FC2

530

FC2 Mobile App

FC

2

Mobile App Quickly Delivers

Fault Current Calculations in the
Palm of Your Hand

• Makes point-to-point calculations easy

• Calculate three-phase and single-phase faults

• Create and e-mail NEC

®

110.24 compliant labels and 

one-line diagrams  

• Fuse Sizing Guide assists with fuse and conductor sizing  

• Works with or without a network connection

• Available for Apple and Android mobile devices

• FC

2

also available on-line in a web-based version

Easily Calculate Available Fault
Current Anytime, Anywhere

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/FC2

531

FC2 Mobile App

Inde

x b
y

P

ar

t Number

Calculator – 

Calculate  Available Fault Current

• Select either three-phase or single-phase 

• Add components, calculate the system’s available fault 

current and review a one-line diagram

• E-mail one-line diagram at anytime 

User Guide – 

Helpful Tips

• Click “User Guide” to view helpful user tips

• Each page has explanations for performing calculations

Contact Us – 

Direct Contact to Industry Leading Support

• Click “Contact Us”

• For application inquiries, click “TECHNICAL SUPPORT” 

• For all other questions, click “CUSTOMER SERVICE”

• The FC

2

app will automatically begin an e-mail to a Bussmann support representative 

One Tool for Easy Available Fault Current Calculations

NEC

®

110.24 Label  – 

Helps Meet the Code

• Allows calculation of the maximum available fault current at 

the service equipment and provides date of calculation

• Create and e-mail a label once a calculation is complete

• Print and use label to post the maximum available fault 

current  

Fuse Sizing Guide – 

For Main, Feeder and Branch 

Circuits

• Click “Fuse Sizing” and “VIEW FUSE SIZING DIAGRAM” 

• Click each  blue “HOT SPOT” link in the one-line 

diagram for fuse and conductor sizing information

How to Use:

How to Install:

1

2

3

4

5

• Use the QR Code

with your device

to download the

mobile app

• Go to the Android or Apple App store

• Search for “Fault Current Calculator” 

make sure to select the Bussmann FC

2

icon

• Click “install” and follow the instructions 

2

1

4

3

5

OR

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

532

Index

532

Catalog Number Index

__NZ01

255

__NZ02

255

_BS

263

_D125

255

_D16

255

_D27

255

_D33

255

_LSC

263

_NHG _ _ _ B

256-258

1025

*

11 Type

438

11239

306

11240

306

11241

306

11242

306

11675-

329

11725-

329

11960

*

13195

*

13926

*

14002-

331

14004-

331

15087

436

15100-_

432

15149

424

15188-3 362

15188-4 362

15242

*

15595

*

15600

*

15602

*

15660

*

15800

430

15900

*

15968

*

160___

329, 330

162___

329, 330

163__

327-328, 329, 330

165___

329, 330

170E_ _ _ _ 201-204, 207-211

170F_ _ _ _

205-206

170H_ _ _ _

212-213

170L

*

170M_ _ _ _

145-199

170N

*

170R

*

170T

*

175GDMSJD

*

175GXQNJD

*

1976

*

1A0065

120

1A0835

*

1A1119-

96

1A1120-

96

1A1310

*

1A1360

*

1A1478

*

1A1706-_

436

1A1837

*

1A1838

*

1A1853

*

1A1907-

96

1A2294

*

1A3398-

96

1A3399-

95

1A3400-

98

1A3746

*

1A4533-

96

1A4534-

96

1A4708

*

1A4806

*

1A5018-

95

1A5600-

84

1A5601-

95

1A5602-

95

1A5603

*

1A5778

84

1A5779

84

1A5780

84

1A5940

*

1A6049

*

1A8654

*

1B0048

*

1B0049

*

1BR021

*

1BR048

*

1BS1_ _ _

141, 213

1CIF

*

2004

*

2081

*

21010

*

2127

*

2178

*

2201

*

2245

*

2322

*

24 Type

438

2429

*

2430

*

2432

*

246B9949BG

*

2487

*

2499

319

25499

*

2601

*

2604

*

2605

*

2607

*

2608

*

2610

*

2611

*

2650

*

2654

*

2698

*

270303

120

2714

*

2772

*

2778

*

2795

*

2834

*

2837

*

2838

*

2839

*

2860

*

2989

*

2992

*

2A066

*

2A8

*

2P25G 345

3356

*

3375

*

3411

*

3429

*

3434

*

3512

*

3513

*

3515

*

3519

*

3520

*

3521

*

3528

*

3531

*

3545

*

3552

*

3553

*

3554

*

3555

*

3556

*

3562

*

3569

*

3571

*

3572

*

3575

*

3576

*

3578

*

3591

*

3594

*

3595

*

3604

*

3723

321

3742

321

3743

321

3823

*

3828

320

3833

*

3835

321

3835

326

3839

*

3959

*

3998

*

39E

*

4121

*

4164

79

4164-FR

79

4178

*

4180

111

4202

*

4261

*

4287

*

4386

*

4393

320

4399

*

4402

*

4405

319

4406

319

4407

*

4408

*

4410

*

4412

*

4413

*

4421

321

4422

*

4423

*

4427

*

4428

*

4482

*

4512

*

4513

*

4514

*

4515

321

4520

320

4522

*

4525

*

4528

111

4529

111

4532

*

4535

*

4537

*

4561

*

4567

*

4574

319

4909

*

51215

*

51235

*

5591-

98

5592-

98

5623

*

5672-

98

5674-

98

5678

*

5681-

97

5682-

97

5950

*

5956-

98

5958

*

5960-

98

5961

*

5TPH

510

6125TD

*

6374

*

63A-DUMMY

*

6415

*

6417

*

6418

*

6419

*

6420

*

64200

74

6422

*

6424

*

6427

*

64300

74

64913

*

64926

*

65372

*

65398

*

68100

*

68300

74

68600

74

7 Type

438

70 Series

436

74 Type

438

75 Type

439

76 Type

439

80 Type

439

8414677

*

8588A81H

*

9078A67G04

120

9435

*

9483

*

9732

*

9789

*

9834

*

9835

*

9838

*

9841

*

9843

*

A3354705

*

A3354710

120

A3354720

*

A3354730  

120

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

* Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

533

Index

533

Catalog Number Index

A3354745  

120

A404302

*

AAO

253

ABC

91

ABCNA

108-109

ABC-V

91

ABGNA

109

ABS

*

ABU

*

ABWNA

108

AC

254

ACB

*

ACF

*

ACH

*

ACK

*

ACL

*

ACO

*

AD

254

ADL

*

ADLSJ

116

ADOSJ

116

AF

*

AFS

*

AFX

*

AGA

90

AGC

91

AGC-V

91

AGU

*

AGW

90

AGX

90

AGX-V

*

AGY

*

AL-D

279

ALS

*

ALW

*

AMG

*

AMI

*

AMWNA

108

ANL

79

ANN

79

ASZ350B3

*

AT

*

AT512 360

ATC

82

ATC-_ID

82

ATC-FHID 82

ATF

*

ATM

82

ATM-_ID

82

ATM-_LP

82

ATM-FHID

83

B221

272

B222

272

BAC_ 388, 391, 393, 395, 397

399, 402, 406, 408, 410

413-414, 419, 421, 423

BAF

75

BAN

*

BAO

253

BB1P_ _

279-280

BB3P_ _

279-280

BBS

77

BBU-EFID

*

BC (fuse blocks)

305

BC (fuses)

254

BC_(separator)

259

BCA603

304

BCC

*

BCF

*

BCPH2_PV

477-478

BD (fuses)

254

BFW

*

BG

305

BGH

*

BH- _ _ _ _

213

BH-_ xxx

141

BH-_(fuseblocks) 306

BM

305

BMA603

304

BNQ21 365

BOOR-508

413-414

BPG_NPE  

468

BPG_NPEWE 486

BPH_-D_LV 460

BPH_YPV  

478, 480

BPM_IEC

468, 470, 472, 474

BPM_UL

450, 452, 454, 456

BPM_WE   486, 488, 490, 492

BPM_YPV

478, 480

BPMA_D_LV 458

BPP_SYPV   

482

BPS_IEC 462, 

464, 

466

BPS_NPEIEC 466

BPSNPEIEC  

470, 474

BPSNPEWE 488, 

492

BQE

365

BQQ41 365

BRKT-_ 349,353

BRT

*

BRW

*

BSPD_DIN_ 499-501

BSPD48RJ45  

497-498

BSPD5BNCD_ 493-494

BSPD5BNCSI 495-496

BSPG_NPE

467-468

BSPH_TNS 473-474

BSPH_TT

469-470

BSPH_TT

473-474

BSPH_WE   487-488, 491-492

BSPH_YPV  

479-480

BSPH2A_D_LV 459-460

BSPM_ S2G 

449-450

BSPM_HLG 455-456

BSPM_S3G 451-452

BSPM_TN 467-468, 

469-470

BSPM_TNC  

471-472

BSPM_WE 485-486

487-488, 489-490, 491-492

BSPM_WYG 453-454

BSPM_WYNG

455-456

BSPM1A_D_LV 457-458

BSPM-DLG 453-454

BSPP

481-482

BSPP_YPV 481-482

BSPS_PV  

475-476

BSPS_TN

461-462

BSPS_TNC 463-464

BSPS_TNS 465-466

BSPS_TT

461-462, 465-466

BSPS_WE

483-484, 485-486

BVL-

259

C_NL

261

C002-0101-_

343

C002-0201 343

C002-0301 343

C08G_

260

C08M

261

C10G_

260

C10M_

261

C14G_

260, 262

C14M_

261, 262

C22G_

260, 262

C22M_

261, 262

C2617

*

C2791

*

C2909

*

C30BS

263

C30F

263

C30FBS

263

C4044

*

C4559

*

C515

86

C517

86

C518

86

C519

86

C520

86

C5237

*

C5268-

141

C5898

*

C60BS

263

C60F

263

C60FBS

263

C6344

*

C7018

*

C7019

*

C7021-

376

C7024-

377

CAV

108-109

CAVH

108-109

CBB

*

CBC

*

CBF

*

CBP

*

CBS

*

CBT

*

CBU

*

CCB

*

CCG

*

CCP-_

380-383

CCPB-_

384-385

CCPHM-_

381,383

CCSK-45

506

CD

254

CD100

*

CD27

*

CDB

*

CDC

*

CDN 247

CDS

247

CEO

253

CFP-_

510

CGL

248

CH10CL

*

CH10CM

*

CH14

277

CH22

277

CH30J_

277, 281

CH60J_

277, 281

CH8

274-277

CHCC

274-277

CHM

274-277

CH-PLC

278

CHPV

274-277

CIF

249

CIH

251

CIK

251

CIL

251

CJ

250

CL1

222

CM__CF

263

CP14002

*

CS_

259

CSC_

334, 335, 336, 337

338,341,343,344,351,352

CT

218-219

CUG

*

DD

254

DDNS10 343

DDP30   

338

DEO

253

DFJ

125

DG100 340

DG150 340

DG230 340

DG25 339

DG35 339

DG60 339

DIA

*

DIR-_

388, 390, 392, 394

396, 398, 402, 406, 408, 410

413-414

DIS10 338

DKNSPS-

334,349

DKSPS_ 

335, 336, 343, 349

DM20 337

DM30 337

DM50 337

DP100

336

DP150

336

DP230

336

DP25  

335, 338

DP45 335

DP60

336

DPLT-_

354

DRA-_

509

DRL_  334, 335, 336, 337, 338

339, 340, 341, 342, 343, 353

358, 359, 360, 362

DRLC-A

*

DS_

335, 336, 338, 343, 345

348, 350, 352

DS20

334

DS30 334

DS50 334

DSS_

334, 350

DTST2 343

E-6188

*

EC-_ _ _

222

ECAP_

279-280

ECL055-

105

ECL083-

106

ECL155-

107

ED

254

EET

218, 220

EF

254

EFS

254

ENA

*

ER1-_800L3PB  

418

ER1-_J3PB

418

ER1-_N3SB  

420, 422

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

* Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)

Inde

x b
y

P

ar

t Number

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

534

Index

534

ER12-_J3PB

418

ER12-_N3SB  

420,422

ER12-800L3PB  

418

ER3R-_J3PB  

418

ER3R-_N3SB  

420, 422

ER3R-800L3PB  

418

ER4-_J3JPB

418

ER4-_N3SB  

420, 422

ER4-800L3PB 418

ER4P-_J3PB  

418

ER4P-_N3SB 420, 

422

ER4P-800L3PB  

418

ER4X-_J3PB

418

ER4X-_N3SB  

420, 422

ER4X-800L3PB 418

ERK-28

507

ERS2

*

ERS30

*

ESD

253

ET

218-219

ETF

*

F01A

*

F02A

*

F02B

*

F03A

*

F03B

*

F09A

*

F09B

*

F10A

*

F15A

*

F16A

*

F520DDST 341

F520ST

341

F520STLED 341

F520T0P  

342

F60C

*

F61C

*

F62C

*

F63C

*

F64C

*

F65C

*

FA02

*

FA2A

*

FA4H

*

FBP

*

FC

*

FC_(fuse  casing)

259

FCB

*

FCC

*

FCF

28-29

FCU

*

FDM

*

FE

218, 221

FEE

218, 221

FEH

259

FF

254

FG

254

FHL

*

FHN

*

FL-

*

FL11H_

117-119

FL11K_

117-119

FL11N

*

FL11T__

117-119

FL12K__   

117-119

FL1A5

*

FL3H

*

FL3K__

117-119

FL3T__

117-119

FLB

*

FLC_ 390, 392, 394, 396, 399

FLD

*

FLF

*

FLH_ 390, 392, 394, 396, 399

FLM

*

FLN

*

FLRM 390, 392, 394, 396, 399

FLS

*

FM

218, 221

FM01A

*

FM08A

*

FM09A

*

FM09B

*

FMM

218, 221

FMX

*

FNA

78

FNM

76

FNQ

76

FNQ-R

24

FNW

*

FP-_

510

FPK_-3P

259

FRN-R

46

FRN-R-__ID

46

FRS-R

47

FRS-R-__ID

47

FT-_

510

FTI

*

FTM

*

FWA

126-129, 224-225

FWC

232-233

FWH

132-133, 228-231

FWJ

139-140, 240-241

FWK

238-239

FWL

242

FWP

136-138, 234-237

FWS

242

FWX

130-131, 226-227

GBA

78

GBB

91

GBB-V

91

GBC

*

GF

254

GFA

*

GG

254

GH

254

GKB

436

GLD

78

GLN

*

GLP

263

GLQ

80

GLR

81

GLX

*

GMA

89

GMA-V

89

GMC

89

GMC-V

89

GMD

89

GMD-V

89

GMF

81

GMQ

80

GMT-_

437

GMW

*

GRF

81

GSK-260

506

GV_

284

H07C

252

H12-_

388,390,392,394,396,398,408

H25_

294-295

H4X-_

388,390,392,394,396,398,402,4

06,408,410,413-414

H60_

296-297

H79-_

388,390,392,395,397,399,402

HAS-R

*

HBC

*

HBH

94

HBH-I

94

HBH-M

94

HBM

*

HBO

*

HBP-

*

HBS-

*

HBV-I

94

HBV-M

94

HBW-I

94

HBW-M

94

HCM

*

HEB

310-311

HEC

310

HEF

*

HEG

309

HEH

309

HEJ

310

HET

310

HEX

310

HEY

310

HEZ

310

HFA

309

HFB

308

HGA

*

HGB

*

HGC

*

HHB

308

HHC

82

HHD

82

HHF

82

HHG

82

HHL

83

HHM

83

HHT

309

HHX

83

HIF

*

HJL

316

HJM

*

HKA

*

HKL

316

HKP

313

HKQ

*

HKR

316

HKT

316

HKU

316

HKX

316

HLD

316

HLQ

80

HLQ-_

80

HLR

81

HLS

437

HLT

437

HM25100

289-293

HM25200

289-293

HM25400

289-293

HM25600

289-293

HM60100

289-293

HM60200

289-293

HM60400

289-293

HM60600

289-293

HME

309

HMF

309

HMG

309

HMH

309

HMI

309

HMJ

309

HMK

*

HMR

*

HN-1

*

HN-5

*

HPC-D

318

HPD

317

HPF

317

HPG

317

HPL

*

HPM

318

HPS

317

HPS2

318

HRE

309

HRF

309

HRG

309

HRH

309

HRI

309

HRJ

309

HRK

308

HSK

*

HTB-

314-315

HTC-140M

95

HTC-15M  

95

HTC-200M

95

HTC-210M

95

HTC-30M

*

HTC-35M

312

HTC-40M

312

HTC-45M

93

HTC-50M

93

HTC-55M

312

HTC-70M

312

HVA

111

HVB

111

HVJ

111

HVL

111

HVR

111

HVT

111

HVU

111

HVW

111

HVX

111

HWA

*

IXL70F

*

J-_ _

511

J101/J

*

J201/J

*

J301/J

*

J60__

298

J70032

243

J70100

243

JB1

*

JCA

*

JCD-

110

JCG-

112

JCH-

112

Catalog Number Index

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

* Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

535

Index

535

JCI-

110

JCK-

112-114

JCK-A-

112-114

JCK-B-

112-114

JCL-

112-114

JCL-A-

112-114

JCL-B-

112-114

JCM

*

JCN

*

JCP

*

JCQ-

110

JCR-A

112-114

JCR-B-

112-114

JCT-

110

JCU-

104

JCW-

110

JCX-

103

JCY-

103

JCZ-

104

JDN

*

JDZ-

104

JF1

*

JJN-

48

JJS-

49

JKS

36

JM60100

289-293

JM60200

289-293

JM60400

289-293

JM60600

289-293

JN_

358, 359, 360, 361

362, 363, 364

JNDN3 358

JP600

299

JPA-3

*

JSK-36

506

JT

286-287

JTN

286-287

JU

*

K07C

252

KAB

*

KAC

134

KAD

364

KAD

*

KAF

*

KAJ

*

KAL

*

KAW

*

KAX

*

KAZ

79

KBC

135

KBD

*

KBJ

*

KBR

*

KBT

*

KBY

*

KCF

74

KCH

74

KCJ

74

KCM

74

KCM-B

74

KCR

74

KCS

74

KCV

74

KCY

74

KCZ

74

KDA

74

KDB

74

KDC

74

KDD

74

KDE

74

KDF

74

KDH

74

KDJ

74

KDM

74

KDP

74

KDR

74

KDT

74

KDU

74

KDY

74

KEF

*

KEM

*

KER

*

KEW

74

KEX

74

KFH-A

74

KFM

74

KFT

74

KFZ

74

KGC

*

KGJ

*

KGJ-A

*

KGJ-E

*

KGL

*

KGO-E

*

KGS

*

KGS-A

*

KGT

*

KGX

*

KIG

74

KIT-6POLE  

413, 415

KJA

*

KLC

*

KLM

75

KLP

*

KLU

40

KMH-C

*

KPF

74

KQO

74

KQT

74

KQV

74

KQW-M

*

KRP-C__SP

38-39

KRP-CL

39

KS-19392-L36

*

KT3 364

KT4 364

KTK

75

KTK-R

25

KTN-R

44

KTN-S

*

KTS-R

45

KTS-S

*

KTU

40

KU_(terminal blocks)

375

KWN-R

*

L09C

252

L14C

252

LAA

*

LAC

*

LAG

*

LAN

*

LAR

*

LCT

215-216

LEF

*

LET

215-216

LKB

*

LKC

*

LKN

*

LKS

*

LMMT

215, 217

LMT

215, 217

LP-CC

23

LPJ__SP

35

LPJ__SPI

35

LPN-RK__SP

41-43

LPN-RK__SPI

41-43

LPRK-28

507

LPS-RK__SP

41-43

LPS-RK__SPI

41-43

LPT

*

LUG1-_

398, 408

LUG2-_

398, 408

LUG3-_

408

LUG5-_

402, 410

M09C

252

MAI

222

MAS

*

MAX-

83

MAX-__ID

83

MB-

52

MBO

*

MC_ _ _

222

MCRW

*

MDA

92

MDA-V

92

MDL

92

MDL-V

92

MDM

*

MDQ

92

MDQ-V

92

MFN

*

MIC

78

MIJ

*

MIN

78

MIS

79

MKB

*

MMT

218, 220

MSK-45

506

MT

218, 220

MT12

*

MT12-1-2  358, 359, 360, 361

363, 364, 365

MTC6 358, 

364

MTMU

*

MV055-

101

MV155-

102

N512 360

NBB

*

NBC

*

NBE

*

NC3 361

ND-1260

*

NDN1 359

NDN111 359

NDN3 358

NDN63 358

NDND1

*

NDNF1-WH

322

NDNFD1-WH

322

NDNLFD1-WH

322

NDNV4 358

NFA

*

NFT2 360

NFT3 360

NFTA Series 

353, 358, 359

360, 361, 362, 363, 365

NI

263

NITD

253

NNB

511

NNB-R

511

NNC

511

NO.1

409

NO.100

*

NO.140

508

NO.2

509

NO.201

*

NO.205

*

NO.213

511

NO.213-R 511

NO.216

511

NO.216-R  

511

NO.220

508

NO.226

511

NO.226-R  

511

NO.242-R

511

NO.2621

511

NO.2621-R

511

NO.263

511

NO.263-R

511

NO.2641

511

NO.2641-R

511

NO.2642

511

NO.2661-R

511

NO.2662-R

511

NO.2664-R

511

NO.270

508

NO.36

507

NO.4

509

NO.5

509

NO.6

509

NO.616

511

NO.616-R 511

NO.626

511

NO.626-R

511

NO.642-R

511

NO.663

511

NO.663-R

511

NO.7

509

NO.8

509

NON

37

NOS

37

NPL

*

NRA Series 

353, 358, 359

360, 361, 362, 363, 365

NSD

253

NSE3 361

NSS3 361

NTN-R-_

511

NTQ23 365

NTS-R-_

511

NUE

*

NXA

*

NXC

*

OIA

*

OJ

*

OPM-1038

282-283

OPM-NG

284-285

OSD

253

P-

51

P09C

252

Catalog Number Index

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

* Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)

Inde

x b
y

P

ar

t Number

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

536

Index

Catalog Number Index

P11C

252

P20S       

344

P25G 345

P30S

344

P65S 344

PCB

*

PCC

*

PCD

*

PCF

*

PCG

*

PCH

*

PCI-

*

PCT

437

PDB___

324, 226

PDBFS___

324-325

PLK3 364

PLU1 363

PLU3 362

PMP

268-269

POLE-_

413, 415

POLE98-_

406

PON

247

PS

268-269

PS1RPLSW

*

PSU1 363

PV-

60

PV-_01XL

63

PV-_01XL15

67-69

PV-_10_

60

PV-_14F

61

PV-_14LF

66

PV-_1XL

63-64

PV-_2XL

63-64

PV-_2XL-15

67-69

PV-_3L

63-64

PV-_3L-15 67-69

PV-_NH1

62

PVCF

57-58

PVM

56

PVS-R

59

PWR1PLP

279-280

PWR35MM   

279-280

PWR50MM

279-280

QC202/J

*

QC203/J

*

Quik-Spe c AC Safety Switch  

271

Quik-Spec Coordination

Panelboards

266-267

Quik-Spec DC Safety Switches 

270

R11C

252

R25_

294-295

R60_

296-297

RD100_

404-406, 420

RD1000_ 404-405, 

410

RD100-3-SCCR 404-405, 

408

RD1200_ 404-405, 

410, 

420

RD16_

412-414, 422

RD200_

404-405, 408, 420

RD25_

412-414, 422

RD30_

404-406, 420

RD40_

412-414, 422

RD400_

404-405, 408, 420

RD60_

404-406, 420

RD600_

404-405, 410, 420

RD63_

412-414, 422

RD80_

412-414, 422

RD800_

404-405, 410, 420

RDF100_

387, 396, 418

RDF200_

387, 398, 418

RDF30_

387-390, 418

RDF400_

387, 398, 418

RDF60_

387, 392-394, 418

RDF600_

387, 402, 418

RDF800_

387, 402, 418

REG

*

REN

*

RES

*

RFL

*

RK1SK-39

506

RK5SK-39

506

RLA

*

RLC

*

RYA

*

RYC

*

S-

51

S500

87

S500-V

87

S501

87

S501-V

87

S505

87

S505H

88

S505H-V   

88

S505-V

87

S506

88

S506-V

88

S-8001

319

S-8002

319

S-8101

319

S-8102

319

S-8201

319

S-8202

219

S-8203

319

S-8301

319

SA-

52

SAMI-

288

SB_

259

SC

34

SCV15

*

SCV20

*

SCY

307

SD_-S

63, 67

SF25H

*

SFB1030

*

SFC-_

510

SFD27

*

SFE

*

SFR

*

SFR1

*

SH1-_

388

SH2-_

388

SH4-_

406, 413-414

SH5-_

390, 392, 394 ,396

398, 408

SH6-_

410

SH7-_

402

SH-GUIDE _ 

406, 408, 410

413-414

SKA

307

SL-

50

SL_

259

SNL-7K

*

SOU

307

SOW

307

SOX

307

SOY

307

SP_

259

SPH50SP_

PN442-445

SPH50SP_

PNG442-445

SPH50SP_

SN442-445

SPH50SP_

SNG442-445

SPH50SP_

WYG 442-445

SPH50SP_

WYGN 442-445

SPH50SP_

HLG 442-445

SPH50SP_DLG

442-445

SPJ

*

SPOD_

502-503

SPP

*

SPP40SP_ DLG

446-448

SPP40SP_ PN

446-448

SPP40SP_ SN

446-448

SPP40SP_ WYG 

446-448

SRD

*

SRT-A

*

SRU

307

SRU-BC

*

SRW

307

SRX

307

SRY

307

SSD

253

SSN

307

SSU

307

SSW

307

SSX

307

SSY

307

STD

253

STI

*

STM

*

STY

307

T-

51

T30__

300-301

T60__

302-303

TB_-D

259

TB00_

259

TB100-

366-367

TB200-

368-369

TB300-

370-371

TB345-

370-371

TB400-

374

TC

51

TCF

26-27

TCF__RN

26-27

TCFH_N

32-33

TCFH_NW  32-33

TCP

*

TDC

*

TDC10

*

TDC11

*

TDC180

*

TDC600

*

TDLEJ

116

TDLSJ

116

TDMEJ

116

TDQSJ

116

TFC

*

TFF

*

TFL

*

TFLSJ

116

TFMEJ

116

TFQSJ

116

TGH

*

THLEJ

116

THMEJ

116

TI_

222

TIQ

*

TJD

*

TKLEJ

116

TKMEJ

116

TL-

50

TM2_

334, 335, 336, 337

338, 341, 343, 344, 345

354-357

TP158HC

431

TP15900

*

TP15900-4_429

TP15914

428

TPA

429

TPA-B

429

TPB

*

TPC

426

TPCDS

426

TPH

*

TPHCS-_  433

TPJ

*

TPL-_

434

TPM

427

TPMDS

427

TPN-_

435

TPS

430

TPSFH-_

510

TPW

*

TPWDS

*

TRF

*

TSH_-_

399, 402, 406, 409

411, 413, 415, 419, 421, 423

TVS_        

504

TVSS-

*

TXLEJ

116

TXMEJ

116

TXQEJ

116

UHA

*

UHC

*

UHJ

*

UHS

*

UHT

*

UHW

*

ULR

*

VFNHA

115

VKNHA

115

W-

50

WCF

30-31

WCF__RN

30-31

WDFHO

115

WDLSJ

115-116

WDOH6

115

WDOSJ

116

WER

438

WFFHO

115

WFLSJ

115-116

WFMSJ

115

WFNHO

115

WFOH6

115

WFOSJ

116

WGA

*

WHA

*

WHN

*

WIE

*

WJON6 115

WKB

*

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Pagember

* Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

537

Index

Catalog Number Index

WKFHO

115

WKH

*

WKJ

*

WKK

*

WKL

*

WKLSJ

116

WKMSJ

115-116

WKNHO

115

WKS

*

WKU

*

WKV

*

WLF

*

WMB

*

WMM

*

WMQ

*

WPQ

*

WQN

*

WQP

*

WSE

*

WSH

*

WSL

*

WSM

*

WSQ

*

WST

*

WSU

*

WTJ

*

WTK

*

WTT

*

WTZ

*

WUE

*

WUG

*

WUH

*

WUI

*

WUQ

*

WUR

*

WUU

*

WUV

*

WUW

*

WUY

*

WVA

*

WVQ

*

WVR

*

WWD

*

WWE

*

WWG

*

WWI

*

WWK

*

WWU

*

WWV

*

WWX

*

WYM

*

WZC

*

WZJ

*

WZK

*

WZX

*

XL25X

*

XL50F

*

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

Catalog

Page

Number

* Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)

Inde

x b
y

P

ar

t Number

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

538

North America

Bussmann Business Headquarters

114 Old State Road
Ellisville, Missouri 63021
Telephone:  636-527-3877
Fax:  800-544-2570
Email:  fusebox@cooperindustries.com

Bussmann Mexico

Poniente 148 #933
Col. Industrial Vallejo
Azcapotzalco C.P. 02300, 
Mexico D.F.
Telephone:  +52-5587-0211 Ext.720
01-800-8-FUSEMX (387369)
Fax:  +52-55-5567-1131
E-mail: ventasbussmannmexico@cooperindustries.com

Bussmann Transportation

10955 SW Avery St.
Tualatin, OR 97062
Telephone: 503-692-5360
Fax: 503-692-9091
E-mail: SurePower.Sales@cooperindustries.com

Bussmann Electronics

1225 F Broken Sound Parkway NW
Boca Raton, FL  33487
Telephone:  561-988-4100
Fax:  561-241-6640
E-mail: customerservice@cooperindustries.com

Asia

Cooper Electric (Shanghai) Co. Ltd.

955 Shengli Road Heqing Pudong, Shanghai 201201 
China
Telephone:  8621-2899-3888
Fax:  8621-2899-3997

Bussmann India

Bussmann, India, Pvt. Ltd.
2, EVR Street, 
Sedarpet Indl. Estate,
Pondicherry – 605 111
India
Telephone:  91-413-267-2005
Fax:  91-413-267-8182
E-mail: sales.india@cooperindustries.com

Europe

Cooper (UK) Ltd.

Melton Road
Burton-on-the-Wolds
Leicestershire LE12 5TH  
England
Telephone:  44-1509-882737
Fax:  44-1509-882786
E-mail: bule.sales@cooperindustries.com

South America

Bussmann Brazil

Bussmann do Brasil Ltda.
Rodovia Santos Dumont, km 23
13.300-000, Caixa Postal 095
Itu Sao Paulo 
Brazil
Telephone:  55-11-4024-8400
Fax:  55-11-40-24-8424

Sales Support & Manufacturing Facilities

Sales & Support

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

539

NOTES

Inde

x b
y

P

ar

t Number

Notes

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product data sheets, visit www.cooperbussmann.com/DatasheetsEle

540

Notes

Notes

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle

Th

c

o

mpara

t

iv

ca

t

al

o

g

 

numb

e

r

s s

h

ow

n

 we

r

d

e

riv

e

d

 

fr

o

m

 t

h

la

test 

availabl

publi

s

h

e

d

 

inf

o

rma

t

i

o

n

 

fr

o

m

 

vari

o

u

manufac

t

ur

e

r

s. 

Be

cau

se 

c

o

mp

et

i

to

r

s’ 

pr

o

duc

ts 

may

 

diff

e

r

 

fr

o

m

 B

u

ss

mann

 

pr

o

duc

ts, 

i

i

r

e

c

o

mm

e

nd

e

d

 t

ha

t e

ach

 

applica

t

i

o

n

 

b

ch

e

ck

e

d

 

f

o

r

 

r

e

quir

e

d

 

e

l

e

c

t

rical

 

and

 

m

e

chanical

 

charac

te

ri

st

ic

b

e

f

o

r

e s

ub

st

i

t

u

t

i

o

n

ar

mad

e. B

u

ss

mann

 

i

n

ot 

r

es

p

o

n

s

ibl

f

o

r

 

mi

s

applica

t

i

o

n

s o

f

 o

ur

 

pr

o

duc

ts.

O

v

e

rcurr

e

n

pr

ote

c

t

i

o

n

 

i

applica

t

i

o

n

 

d

e

p

e

nd

e

n

t. Co

n

s

ul

t t

h

la

test 

ca

t

al

o

g

and

 

applica

t

i

o

n

 

li

te

ra

t

ur

e, o

r

 

c

o

n

t

ac

t o

ur

 

Applica

t

i

o

n

 

E

ngin

ee

ring

 De

par

t

m

e

n

t to

ll

 

fr

ee 

a

t 8

55-

28

7-7

626 

(

8

55-

B

U

SSM

A

NN

)

.

B

u

ss

mann

 

Fu

se C

r

oss 

R

e

f

e

r

e

n

ce 

&

 

L

ow

-P

e

ak

Up

g

rad

e

Th

l

e

f

c

o

lumn

 

r

e

pr

ese

n

ts B

u

ss

mann

 

and

 

c

o

mp

et

i

to

r

s’ 

par

numb

e

r

s. 

Th

righ

c

o

lumn

 

r

e

pr

ese

n

ts t

h

e B

u

ss

mann

 

upgrad

es.

Th

e B

u

ss

mann

 

fu

se 

upgrad

e o

ff

e

r

s s

up

e

ri

o

r

 

p

e

rf

o

rmanc

e w

hil

r

e

ducing

 t

h

numb

e

r

 o

f

 S

KU

s

t

ha

n

ee

d

 to 

b

in

 sto

ck

L

ow

-P

e

ak

fu

ses 

f

e

a

t

ur

a

high

 

d

e

gr

ee o

f

 

curr

e

n

limi

t

a

t

i

o

n

, w

hich

 w

ill

 

pr

o

vid

e

t

h

b

est 

c

o

mp

o

n

e

n

pr

ote

c

t

i

o

n

 

and

 

may

 

r

e

duc

e t

h

e

arc

 

fla

s

h

 

ha

z

ard

Li

st

ing

ar

alpha-num

e

rical

 

by

fu

se 

cla

ss 

and

 

fu

se 

ca

t

al

o

g

 s

ymb

o

l

.

Thi

li

st 

i

s o

nly

 

a

 

c

o

n

so

lida

te

d

 

cr

oss 

r

e

f

e

r

e

nc

e to

so

m

e o

f

 o

ur

 

m

ost 

c

o

mm

o

n

 

pr

o

duc

ts. 

F

o

r

 

a

 

much

m

o

r

e e

x

te

n

s

iv

da

t

aba

se 

pl

e

a

se 

c

o

n

s

ul

t t

h

Pr

o

du

ct

Pr

o

fil

e

r

c

o

mp

et

i

to

r

 

cr

oss

-r

e

f

e

r

e

nc

e. 

Ju

st 

vi

s

i

t

www.

c

oo

p

e

rbu

ss

mann

.

c

o

m

 

and

 

click

 o

n

 t

h

magnifying

 

gla

ss 

ic

o

n

 

in

 t

h

upp

e

r

 

righ

c

o

rn

e

r

.

C

la

ss CC 

and

 

Mid

get

          E

xi

st

in

Fu

se                           

L

ow

-P

e

ak

Up

g

rad

e

          

A

6

Y

 

(

t

yp

e 2B

)

                            

LP-

CC

          

A

B

U

          

AGU

          

AT

D

R

          

AT

M

          

AT

M

R

          

ATQ

          B

AF

          B

A

N

          B

LF

          B

L

N

          CCM

R

          CM
          CM

F

          CNM
          CN

Q

          C

TK

          C

TK-R

          

FL

M

          

FLQ

          

F

NM

          

F

N

Q

          

GGU

          

H

C

LR

          

KLK

          

KLK-R

          

KTK

          

KTK-R

          MC

L

          MEN
          ME

Q

          MO

F

          MO

L

          O

T

M

          

TR

M

          6

JX

                                          

LP-

CC

*F

N

Q-R

 s

u

ggeste

d

 o

n

 

primary

 o

f

 co

n

t

r

o

l

 t

ran

s

f

o

rm

e

r

s.

          

ATQR

          

F

N

Q-R

                                      

F

N

Q-R

          

KL

D

R

250 

V

o

l

t C

la

ss 

R

          E

xi

st

in

Fu

se                           

L

ow

-P

e

ak

Up

g

rad

e

          

A

2D                                          

LP

N

-RK

_S

P

          

A

2D

-R

          

A

2

K

          

A

2

K-R

          

A

2

Y

 

(

t

yp

1)

          

AT-

DE

          C

HG

          C

R

N

-R

 

(

t

yp

e 3

)

          C

T

N

-R

          DEN
          D

L

N

          D

L

N

-R

          ECN
          ECN

-R

          E

R

N

          

FL

N

          

FL

N

-R

          

FR

N

          

FR

N

-R

          

FT

N

-R

          

G

DN

          

HA

C

-R

          

H

B

          

KL

N

-R

          

K

ON

          

KT

N

-R

          

L

EN

RK

          

LK

N

          

LL

N

-RK

          

L

ON

-RK

          NC

LR

          N

L

N

          NON
          N

R

N

          O

T

N

          

R

EN

          

RF

N

          

RH

N

          

RL

N

          

TR

          6

55

          660
          

1

0

K

O

T

N

          

5

0

K

O

T

N                                    

LP

N

-RK

_S

P

600 

V

o

l

t C

la

ss 

R

          E

xi

st

in

Fu

se                           

L

ow

-P

e

ak

Up

g

rad

e

          

A

6D                                          

LP

S

-RK

_S

P

          

A

6

K-R

          

A

6

X

 

(

t

yp

1)

          

AT

S

-

DE

          C

HR

          C

T

S

-R

          DES
          DES

-R

          D

L

S

          D

L

S

-R

          ECS

-R

          E

R

S

          

FL

S

          

FL

S

-R

          

FR

S

          

FR

S

-R

          

FT

S

-R

          

G

DS

          

HA

          

KL

S

-R

          

K

OS

          

KT

S

-R

          

L

ES

          

L

ES

-R

          

L

ES

-RK

          

LK

S

          

LL

S

-RK

          

L

OS

-RK

          N

L

S

          NOS
          N

R

S

          O

T

S

          

R

ES

          

RF

S

          

RH

S

          

RL

S

          SC

LR

          

TR

S

          

TR

S

-R

          6

5

6

          

1

0

K

O

T

S

          

5

0

K

O

T

S                                    

LP

S

-RK

_S

P

C

la

ss 

L

          E

xi

st

in

Fu

se                           

L

ow

-P

e

ak

Up

g

rad

e

          

A4

B

Q

                                       

KRP-

C_S

P

          

A4

B

T

          

A4

B

Y

          

A4

B

Y

 

(

t

yp

55)

          C

LA

SS 

L

          C

LF

          C

LL

          C

LU

          

HR

C

-L

          

KLLU

          

KLP

C

          

KLU

          

KTU

          

L

          

L

C

L

          

L

C

U

                                          

KRP-

C_S

P

C

la

ss 

J

          E

xi

st

in

Fu

se                           

L

ow

-P

e

ak

Up

g

rad

e

          

A4J

                                          

LPJ

_S

P

          

AJT

          C

J

          C

J

S

          

GF

8B

          

HR

C

XXJ

          

J

          

JA

          

J

C

L

          

J

D

L

          

JFL

          

JH

C

          

JK

S

          

JL

S

          

JT

D                                           

LPJ

_S

P

C

r

oss 

R

e

f

e

r

e

n

ce & 

L

o

w-P

e

ak™

 

Upgrad

e

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com

Bussmann-catalog-html.html
background image

Customer Assistance

Customer Satisfaction Team

Available to answer questions regarding Bussmann  
products & services Monday-Friday, 7:00 a.m. – 6:00 p.m. 
Central Time. Contact:

UÊ/œ‡vÀiiÊ«…œ˜i\Ênxx‡ÓnLJÇÈÓÈÊ­nxx‡ 1--  ®

UÊ/œ‡vÀiiÊv>Ý\Ênää‡x{{‡ÓxÇä

Uʇ“>ˆ\ÊLÕÃÃVÕÃÌÃ>ÌJVœœ«iÀˆ˜`ÕÃÌÀˆiðVœ“

Emergency and After-Hours Orders

 iÝÌÊvˆ}…ÌʜÕÌʜÀÊ܈ÊV>Êň«“i˜ÌÊvœÀÊ̈“i‡VÀˆÌˆV>Ê˜ii`ðÊ
ÕÃ̜“iÀÃÊ«>Þʜ˜ÞÊÃÌ>˜`>À`Ê«Àœ`ÕVÌÊ«ÀˆVi]ÊÀÕÅÊvÀiˆ}…ÌÊ

 

V…>À}iÃ]ÊEʓœ`iÃÌÊi“iÀ}i˜VÞÊÃiÀۈViÊvii°Ê*>ViÊ̅iÃiÊ

 

œÀ`iÀÃÊ̅ÀœÕ}…Ê̅iÊÕÃ̜“iÀÊ->̈Ãv>V̈œ˜Ê/i>“Ê`ÕÀˆ˜}Ê

 

Ài}Տ>ÀÊLÕȘiÃÃʅœÕÀðÊʜÀÊ>vÌiÀ‡…œÕÀÃ]ÊVœ˜Ì>VÌ\

UÊvÌiÀʅœÕÀÃÊΣ{‡™™x‡£Î{Ó

C3 – the Enhanced, Online Cooper Customer Center

*ÀœÛˆ`iÃÊÀi>Ê̈“iÊ«Àœ`ÕVÌÊ>Û>ˆ>LˆˆÌÞ]ʘiÌÊ«ÀˆVˆ˜}]ʜÀ`iÀÊ

 

ÃÌ>ÌÕÃÊEÊň«“i˜ÌÊÌÀ>VŽˆ˜}ÊvœÀ\Ê ‡ˆ˜i]Ê ÕÃÓ>˜˜]Ê

 

ÀœÕÃi‡ˆ˜`Ã]ʈ}…̈˜}]Ê*œÜiÀÊ-ÞÃÌi“ÃÊEÊ7ˆÀˆ˜}ÊiۈViðÊ

 

>ÊnÇLJ™™x‡x™xxÊvœÀʏœ}‡ˆ˜Ê>ÃÈÃÌ>˜Vi°ÊÛ>ˆ>LiÊ>Ì\

UÊÜÜܰVœœ«iÀVΰVœ“

Application Engineering

/iV…˜ˆV>Ê>ÃÈÃÌ>˜ViʈÃÊ>Û>ˆ>LiÊ̜Ê>ÊVÕÃ̜“iÀðÊ

 

Application support is available Monday-Friday,  

Ç\ääÊ>°“°ÊqÊx\ääÊ«°“°Êi˜ÌÀ>Ê/ˆ“i°Êœ˜Ì>VÌ\

UÊ/œ‡vÀiiÊ«…œ˜i\Ênxx‡ÓnLJÇÈÓÈÊ­nxx‡ 1--  ®

Uʇ“>ˆ\ÊvÕÃiÌiV…JVœœ«iÀˆ˜`ÕÃÌÀˆiðVœ“

Online Resources

6ˆÃˆÌÊÜÜܰVœœ«iÀLÕÃÓ>˜˜°Vœ“ÊvœÀÊ̅iÊvœœÜˆ˜}Ê

 

resources:

UÊ*Àœ`ÕVÌÊÃi>ÀV…ÊEÊVÀœÃÇÀiviÀi˜Vi

UÊ*Àœ`ÕVÌÊEÊÌiV…˜ˆV>Ê“>ÌiÀˆ>Ã

UÊ-œṎœ˜ÃÊVi˜ÌiÀÃÊvœÀʈ˜vœÀ“>̈œ˜Êœ˜Ê̜«ˆV>ÊˆÃÃÕiÃÊ

 

Êʈ˜VÕ`ˆ˜}Ê>ÀVÊv>Å]ÊÃiiV̈ÛiÊVœœÀ`ˆ˜>̈œ˜ÊEÊŜÀ̇VˆÀVՈÌÊ

 

  current rating

UÊ/iV…˜ˆV>Ê̜œÃ]ʏˆŽiʜÕÀÊ>ÀVÊv>ÅÊV>VՏ>̜À

UÊ7…iÀiÊ̜ʫÕÀV…>ÃiÊ ÕÃÓ>˜˜Ê«Àœ`ÕVÌ

Eaton is a registered trademark.  

All other trademarks are property  
of their respective owners.

Eaton

1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

© 2013 Eaton
All Rights Reserved
Printed in USA
Publication No.1007
August 2013

Eaton’s Bussmann Business

PO Box 14460
St. Louis, MO 63178-44602 
www.bussmann.com

Your authorized distributor is: 

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com