background image

PA N D U I T

P

A N

- N

E T

N E T W O R K S O L U T I O N S

Panduit-Pannet-html.html
background image

PANDUIT

is a Global Leader in

Innovative Cabling and Networking Solutions.

End-to-End

Network Connectivity Solutions

from the Work Area to the

Telecommunications Room

For more information visit: www.panduit.com/emea

M

INI

-C

OM

Angled

Modular Patch Panels

DP

O

E

Power Patch Panel

M

INI

-C

OM

U

LTIMATE

ID

Faceplates

TX6

10G

IG

Jack Modules

Q

UICK

N

ET

Pre-Terminated

MTP* Cassettes

*MTP is a registered trademark of US Conec Ltd.

Panduit-Pannet-html.html
background image

i

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

T

ABLE OF

C

ONTENTS

i

System Overview

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Global Services and Support  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

System Overview

Copper and Line Cards Solution

Copper and Line Cards Solution

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

CAT5e Unshielded TX Solution  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
CAT5e Shielded TX Solution  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
CAT6 

PLUS Unshielded TX Solution  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

CAT6 

PLUS Shielded TX Solution  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

TX6 10G UTP Solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
TX6 10G Shielded Solution  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Condensed Fibre Solution Line Card/Singlemode  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15
Condensed Fibre Solution Line Cards/Multimode  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-17

Modules

Modules

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

M

INI

-C

OM

TX6

PLUS Jack Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Component Labels for 

M

INI

-C

OM

TX6

PLUS Jack Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

M

INI

-C

OM

TX6

PLUS Shielded Jack Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

M

INI

-C

OM

TX5e

Jack Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

M

INI

-C

OM

TX5e

Shielded Jack Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Component Labels for 

M

INI

-C

OM

TX5e

Jack Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

I

NDUSTRIAL

N

ET

TX6

Connectors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

I

NDUSTRIAL

N

ET

TX5e

Connectors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

I

NDUSTRIAL

N

ET

TX5e

Patch Cords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

Self-Laminating Labels for IUTPCH 

I

NDUSTRIAL

N

ET

TX5e

Patch Cords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

I

NDUSTRIAL

N

ET

TX5e

LC Fibre Connectors and Patch Cords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

I

NDUSTRIAL

N

ET

Stainless Steel Faceplates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

I

NDUSTRIAL

N

ET

Ethernet Enclosure  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

M

INI

-C

OM

M

INI

-J

ACK

Category 3 Jack Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

Component Labels for 

M

INI

-C

OM

M

INI

-J

ACK

Category 3 Jack Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

M

INI

-C

OM

5-Way Binding Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

M

INI

-C

OM

3.5mm Stereo Connector Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

M

INI

-C

OM

BNC Coax Coupler Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

M

INI

-C

OM

Self-Terminating F-Type Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

M

INI

-C

OM

F-Type Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

M

INI

-C

OM

RCA 110 Punchdown Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

M

INI

-C

OM

RCA Pass-Through Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27

M

INI

-C

OM

S-Video Punchdown Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27

M

INI

-C

OM

S-Video Pass-Through Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27

M

INI

-C

OM

Module Base for D-Subminiature Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27

M

INI

-C

OM

LC Sr./Jr. Fibre Optic Adapter Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

M

INI

-C

OM

MT-RJ Fibre Optic Adapter Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

M

INI

-C

OM

ST Fibre Optic Adapter Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

M

INI

-C

OM

FC Fibre Optic Adapter Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

M

INI

-C

OM

Blank Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

Module Termination Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

Work Area Solutions (Faceplates)

Work Area Solutions

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31

M

INI

-C

OM

UK Faceplates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

UK Sloped Shuttered Faceplate Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
M

INI

-C

OM

UK Bezels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

UK Sloped Faceplates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
UK Outlet Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
25 x 50 Euro-Mode Shuttered Adopter Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
M

INI

-C

OM

German Faceplates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33

German Faceplate and Adapter Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
German Floor Box Sloped Faceplate  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
German Faceplate for Ackermann GB2 Sub Box  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
M

INI

-C

OM

German Bezels and Adapters  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34

German Faceplates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35

Panduit-Pannet-html.html
background image

ii

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

T

ABLE OF

C

ONTENTS

Work Area Solutions (Faceplates)

M

INI

-C

OM

French Faceplates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35

M

INI

-C

OM

French Faceplate Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35

French Adapter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
M

INI

-C

OM

Italian Designer Series Faceplates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

M

INI

-C

OM

Italian Classic Series Faceplates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

Italian Gewiss Adapter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Italian Vimar Adapter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
M

INI

-C

OM

Switzerland Faceplate  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37

Switzerland Faceplate  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
M

INI

-C

OM

Switzerland Bezel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37

M

INI

-C

OM

Denmark Sloped Faceplates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37

Denmark Sloped Faceplate Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Denmark adapters for 

C

LIC

LINE

and 

O

PUS

66

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37

Adapter for Legrand 

G

ALEA

and 

V

ALENA

faceplates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38

Thorsman* Perimeter Trunking Faceplates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Elko Faceplate - Sweden, Norway, Denmark and Netherlands  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Module Inserts for Bezels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Wall Board Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
M

INI

-C

OM

In-Wall Fibre Spool  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40

M

INI

-C

OM

Snap-On Modular Furniture Faceplate  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40

M

INI

-C

OM

Shuttered Surface Mount Boxes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41

M

INI

-C

OM

Surface Mount Boxes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42-43

M

INI

-C

OM

Multi-Media/Fibre Surface Mount Boxes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43

P

AN

Z

ONE

Zone Cabling Solutions

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

45

Zone Cabling Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46-47
Punchdown Consolidation Point Enclosure  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Consolidation Point Boxes and Fibre Conversion Kit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
P

AN

Z

ONE

In-floor Zone Cabling Boxes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49

P

AN

Z

ONE

In-ceiling  Zone Cabling Box  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49

P

AN

Z

ONE

Active In-ceiling Zone Cabling Box  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49

P

AN

Z

ONE

Active Wall Mount Enclosure  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50

P

AN

Z

ONE

Enclosures  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50

C

ABLE

A

CCESS

Wall Mount Cabinet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51

C

ABLE

A

CCESS

Wireless Access Point Enclosure  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51

P

ANZONE

Cable Assemblies  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51-52

Zone Cabling Solutions

Patch Panels, Copper Patch Cords and Punchdowns

Patch Panels, Copper Patch Cords and Punchdowns

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

53

Copper Connectivity System Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54-55
Component Labels for 

DP

O

E

Power Patch Panel and Power System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57

Module Termination Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
M

INI

-C

OM

Modular Faceplate Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57

Component Labels for 

M

INI

-C

OM

Modular Faceplate Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58

M

INI

-C

OM

M6 Style Modular Faceplate Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58

Component Labels for 

M

INI

-C

OM

M6 Style Modular Faceplate Patch Panels   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58

M

INI

-C

OM

High Density Modular Faceplate Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59

Component Labels for 

M

INI

-C

OM

High Density Modular Faceplate Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59

M

INI

-C

OM

Flush Mount Modular Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59

M

INI

-C

OM

Angled High Density Modular Patch Panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60

M

INI

-C

OM

Angled Modular Faceplate Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60

Component Labels for 

M

INI

-C

OM

Angled Modular Faceplate Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60

M

INI

-C

OM

Recessed Modular Faceplate Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61

Component Labels for 

M

INI

-C

OM

Recessed Modular Faceplate Patch Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61

M

INI

-C

OM

12 Port Modular Faceplate Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61

Component Labels for 

M

INI

-C

OM

12 Port Modular Faceplate Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61

M

INI

-C

OM

All Metal Shielded Modular Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62

Component Labels for 

M

INI

-C

OM

All Metal Shielded Modular Patch Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62

DP6

10G

IG

Modular Punchdown Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63

DP6

PLUS Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63

Component Labels for 

DP6

PLUS Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64

DP5e

Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64

Panduit-Pannet-html.html
background image

iii

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

T

ABLE OF

C

ONTENTS

Component Labels for 

DP5e

Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64

Self-Laminating Labels for 

TX6

PLUS Patch Cords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64

D

ATA

-P

ATCH

10/100 Base-T Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64

Component Labels for 

D

ATA

-P

ATCH

10/100 Base-T Patch Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65

D

ATA

-P

ATCH

10/100 Base-T Cable Assemblies  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65

Self-Laminating Labels for 

D

ATA

-P

ATCH

10/100 Base-T Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65

Voice Patch Panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Self-Laminating Labels for Category 5e Patch Cords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Component Labels for Voice Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Coupler Patch Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Strain Relief Bars  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
TX6

PLUS Modular Plug  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67

P

AN

-P

LUG

High Performance Modular Plugs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67

Modular Plug Termination Tools  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
TX6

10G

IG

Patch Cords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68

TX6

PLUS Category 6 Patch Cords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68

Shielded 

10G

IG

LSZH Category 6 Patch Cords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69

Self-Laminating Labels for 

TX6

PLUS Patch Cords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69

Self-Laminating Cable Marker Holders for Large Cables or Cable Bundles  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
Component Labels for Self-Laminating Cable Marker Holders for Large Cables or Cable Bundles  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Category 5e Patch Cords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Shielded Category 5e LSZH Patch Cords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Self-Laminating Labels for Category 5e Patch Cords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
GP6

PLUS Punchdown System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71

GP6

PLUS Category 6 High Density Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71

Component Labels for 

GP6

PLUS Systems  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71

GP6

PLUS Category 6 Standard Density Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72

GP6

PLUS Category 6 High Density Rack Mount Panel Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72

GP6

PLUS Category 6 Standard Density Kits Rack Mount Panel Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73

GP6

PLUS Category 6 Connecting Blocks  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73

GP6

PLUS Category 6 High Density Bases  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74

GP6

PLUS Category 6 Standard Density Bases  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74

GP6

PLUS Category 6 Standard Density Tower Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75

Jumper Troughs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
GP6

PLUS Termination Tools and Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76

GP6

PLUS Patch Connectors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76

P

AN

-P

UNCH

110 Category 5e System Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77

Punchdown Rack Mount Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
P

AN

-P

UNCH

Category 5e 19” Rack Mount Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78

P

AN

-P

UNCH

Category 5e 19” Mount Panel Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78

P

AN

-P

UNCH

110 Category 5e Tower System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79

Vertical Cable Managers for Tower Systems  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
19” Rack Mount Bracket Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
P

AN

-P

UNCH

110 Category 5e Connecting Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80

P

AN

-P

UNCH

110 Category 5e Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81

Jumper Troughs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
Punchdown Designation Label Holder  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
Component Labels for 110 Punchdown Designation Label Holders  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
GP6

PLUS Patch Cord Assemblies  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82

Self-Laminating Labels for 

GP6

PLUS Patch Cord Assemblies  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82

GIGA

-P

UNCH

1 and 2 Pair Patch Cord Assemblies  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83

Self-Laminating Labels for 

GIGA

-P

UNCH

1 and 2 Pair Patch Cord Assemblies  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83

P

AN

-P

UNCH

Punchdown Tools and Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83

P

AN

-P

UNCH

110 Patch Connectors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84

P

AN

-P

UNCH

110 Patch Cord Assemblies  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84

Self-Laminating Labels for 

G

IGA

-P

UNCH

1 and 2 Pair Patch Cord Assemblies  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84

PANDUIT

TX

5500 Category 5e UTP Copper Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85

PANDUIT

TX

5500 Category 5e FTP Copper Cable  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85

PANDUIT

TX

5500 Category 5e S/FTP Copper Cable  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85

PANDUIT

TX

6000 Category 6 UTP Copper Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86

PANDUIT

TX

6000 Category 6 FTP Copper Cable  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86

PANDUIT

TX

6000 Category 6 SFTP Copper Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86

PANDUIT

TX6

10G

IG

UTP Copper Cable  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87

PANDUIT

TX

7000

10G

IG

Category 7 600MH

Z

S-STP Copper Cable  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87

Patch Panels, Copper Patch Cords and Punchdowns (continued)

Panduit-Pannet-html.html
background image

iv

T

ABLE OF

C

ONTENTS

iv

Fibre Connectors, Enclosures and Patch Cords

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

89

Fibre Optic Connectors, Enclosures and Patch Cords Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90-91
ST* Fibre Optic Connectors - Field Polish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
ST* 

O

PTI

-C

RIMP

Fibre Optic Connectors - Pre-polished Crimp  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92

M

INI

-C

OM

ST

*

Fibre Optic Adapter Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92

LC 

O

PTI

C

AM

Fibre Optic Connectors - Pre-Polished Cam Termination  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93

SC 

O

PTI

C

AM

Fibre Optic Connectors - Pre-Polished Cam Termination  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94

SC Fibre Optic Connectors - Field Polish  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
SC Fibre Optic Adapters  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
M

INI

-C

OM

SC Fibre Optic Adapter Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96

LC Simplex Fibre Optic Connectors - Field Polish  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96
LC Duplex Fibre Optic Connectors - Field Polish  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97
LC Duplex Connectors for 900μ Buffered Fibre  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97
LC Sr/Sr Fibre Optic Adapters  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98
M

INI

-C

OM

LC Sr/Sr Fibre Optic Adapter Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98

M

INI

-C

OM

FJ

O

PTI

-C

RIMP

Keyed Duplex Jack Modules - Pre-polished Crimp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99

Replacement Ferrule Assemblies for FJ

O

PTI

-C

RIMP

Jack Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99

M

INI

-C

OM

FJ Duplex Fibre Optic Jack Modules - Field Polish  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100

M

INI

-C

OM

FJ Keyed Duplex Jack Modules - Field Polish  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100

M

INI

-C

OM

FJ 

O

PTI

-C

RIMP

Duplex Jack Modules - Pre-polished Crimp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101

Component Labels for 

M

INI

-C

OM

FJ 

O

PTI

-C

RIMP

Duplex Jack Modules - Pre-polished Crimp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101

Replacement Ferrule Assemblies for FJ Field Polish Jack Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101
FJ Duplex Fibre Optic Plugs - Field Polish  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102
FJ Keyed Duplex Fibre Optic Plugs - Field Polish  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102
FJ -SC Connectors for termination on 1.6mm Fibre Cable  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103
Replacement Ferrule Assemblies for FJ Field Polish Plugs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103
LC & SC Duplex Clips Components  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103
M

INI

-C

OM

LC Sr/Jr Fibre Optic Adapter Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104

M

INI

-C

OM

MT-RJ Fibre Optic Adapter Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104

250 Micron Fibre Build-Up Tube Kit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
M

INI

-C

OM

FC Fibre Optic Adapter Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105

M

INI

-C

OM

Blank Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105

Pre-Polished Fibre Optic Termination Kits - 

O

PTI

C

AM

and 

O

PTI

-C

RIMP

Connectors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106

Components for Pre-Polished Fibre Optic Termination Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
O

PTI

-C

RIMP

Fibre Optic Termination Kit - Pre-Polished Crimp  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107

Components for 

O

PTI

-C

RIMP

Fibre Optic Termination Kit (FJMVKIT)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107

LC Field Polish Fibre Optic Termination Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
Components for LC Field Polish Fibre Optic Termination Kit (FLPKIT)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
Field Polish Fibre Optic Termination Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Components for Field Polish Fibre Optic Termination Kit (FJKITG)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
O

PTICOM

Rack Mount Splice Enclosures  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110

O

PTICOM

Fibre Optic Rack Mount Splice Enclosures  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110

O

PTICOM

PreLoaded Trays  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111

O

PTICOM

Trays  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111

Fibre Adapter Patch Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112
O

PTICOM

Drawers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112

O

PTICOM

Pre-Terminated Trays and Drawers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113

O

PTICOM

Wall Mount Enclosures  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114

O

PTICOM

Pre-Terminated Wall Mount Enclosures  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114

O

PTICOM

Fibre Adapter Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115-116

O

PTICOM

Pre-Terminated Cassettes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116

O

PTICOM

Optical Component Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117

O

PTICOM

Splice Trays and Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117

Fibre Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118
Optical Fibre Network Saddle (Dual Capacity)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118
Optical Fibre Network Saddle  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118
Multimode 62.5/125μ or 50/125μ Patch Cords and Pigtails  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119
Self-Laminating Labels for Fibre Optic Patch Cords and Pigtails - Multimode 62.5/125μ or 50/125  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119
Multimode 62.5/125μ or 50/125μ Patch Cords and Pigtails (continued)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
Self-Laminating Labels for Fibre Optic Patch Cords and Pigtails - Multimode 62.5/125μ or 50/125 (continued) . . . . . . . . . . . . . . . . . . . . . .120
Fan-Out Cords - Multimode 62.5/125μm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121
MPO Fibre Optic Cords - Multimode 62.5/125μm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122
Self-Laminating Labels for MPO Fibre Optic Cords - Multimode 62.5/125μm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122
O

PTI

-C

ORE

10G

IG

50/125μm Patch Cords and Pigtails  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123-124

Self-Laminating Labels for Fibre Optic Patch Cords and Pigtails - 

O

PTI

-C

ORE

10G

IG

50/125μm  . . . . . . . . . . . . . . . . . . . . . . . . . . . .123-124

Singlemode 9/1.25μm Patch Cords and Pigtails  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125-126
Self-Laminating Labels for Fibre Optic Patch Cords and Pigtails - Singlemode 9/125μm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125-126
Fan-Out Cords Singlemode 9/125μm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
Fan-Out Cords Singlemode 9/125μm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127

Fibre Connectors, Enclosures and Patch Cords

Panduit-Pannet-html.html
background image

T

ABLE OF

C

ONTENTS

v

MPO Fibre Optic Cords - Singlemode 9/125μm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
Furcation Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128
250 Micron Fibre Build-Up Tube Kit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128
FJ Loopback Connector Assemblies  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128
SC Terminator  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129
L

ABEL

C

ORE

Fibre Optic Cable Indentification System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129

Fibre Connectors, Enclosures and Patch Cords (continued)

Racks and Cable Management

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

131

N

ET

F

RAME

Cable Management Rack System Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132-133

N

ET

F

RAME

Rack System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134

NetRack Management System and Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
4 Post Rack and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135
P

ATCH

R

UNNER

Vertical Cable Management Rack System Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .136-137

P

ATCH

R

UNNER

Vertical Cable Management System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138

Communication Cable Management Accessories Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Standard Cable Management Rack System Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140-141
Standard Racks and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142
Rack Mountable Troughs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142
Shelves  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143
Panel Extender Brackets  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143
Hinged Wall Brackets  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144
Filler Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144
Standard Vertical Slotted Duct  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
Angled Filler Panels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
IN-Cabinet Vertical Cable Managers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146
Communication Cable Management Kit for Cabinets  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146
N

ET

M

ANAGER

Horizontal Cable Managers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147

P

ATCH

L

INK

Horizontal Cable Managers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148

O

PEN

-A

CCESS

Cable Management  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149

O

PEN

A

CCESS

Horizontal D-rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150

Vertical D-Rings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150
Active Equipment Cable Managers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151
Bend Radius Control Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151
Bundle Retainers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151
Stackable Cable Rack Spacers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151
Waterfall Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151
Flat 

P

AN

-P

OST

Standoff  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153

O

PTICOM

HD Cross Connect System Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154-155

O

PTICOM

HD Inter-Connect System Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156

O

PTICOM

HD Fibre Distribution Equipment Racks and Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157

O

PTICOM

HD Fibre Distribution Enclosures, Splice Trays and Holders  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157

Racks and Cable Management

Grounding & Bonding

Grounding & Bonding

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

159

Grounding & Bonding System Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160-161
Grounding Kit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162
Telecommunication Rack Grounding Products  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162
Copper Lugs - One-Hole Lug Standard Barrel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163-164
Copper Lugs - One-Hole Lug Standard Barrel, 45

Angle Tongue  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165-166

Copper Lugs - One-Hole Lug Standard Barrel, 90

Angle Tongue  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167-168

Copper Lugs - Two-Hole Lug Standard Barrel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169-170
Copper Lugs - Two-Hole Lug Standard Barrel, 45

Angle Tongue  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171

Copper Lugs - Two-Hole Lug Standard Barrel, 90

Angle Tongue  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172

Copper Lugs - Two-Hole Lug Long Barrel, with Inspection Window  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173-174
Copper Lugs - Two-Hole Lug Long Barrel, with Window - 90

Angle Tongue  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177-178

Copper Splices - Butt Splices, Standard Barrel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179
Copper Splices - Butt Splices, Long Barrel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179
C-Type Taps - Thick Wall Copper Compression  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
C-Type Taps - Thin Wall Copper Compression  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
CTAP Covers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
HTAP Copper Compression Taps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181
HTAP Covers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181
Bronze Service Post Connectors - Type SP1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182
Bronze Service Post Connectors - Type SP2  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182
Bronze Service Post Connectors - Type SPF1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183

Panduit-Pannet-html.html
background image

vi

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

T

ABLE OF

C

ONTENTS

vi

^ WINDOWS is a trademark of Microsoft Corp 

Grounding & Bonding (continued)

Bronze Service Post Connectors - Type SPF2  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183
T

APER

-S

LICE

In-Line Reducer  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184

T

APER

-S

LICE

Kits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184

Bronze Grounding Clamps - U-Bolt Style . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
Bronze Grounding Pipe Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
Heavy Duty Crimp Tool - Hand Operated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186
Dies for CT-720  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186
Kits for CT-720  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187
C

ONTOUR

C

RIMP

Controlled Cycle Crimp Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187

C

ONTOUR

C

RIMP

Controlled Cycle Crimp Tools  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187

Controlled Cycle Hydraulic Crimp Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .188
Crimp Dies - CD-920  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .188
Hydraulic Crimp Tool, Dieless  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189
Ring Terminal Nylon Insulated  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190
Ring Terminal Nylon Insulated - Expanded Insulation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190
Ring Terminal Vinyl Insulated - Funnel Entry  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191
Ring Terminal Vinyl Insulated - Expanded Insulation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191
Ring Terminal Non-Insulated  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191
Common Conductor Sizes and Strandings Reference Chart  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192-193
Equivalent Tables Decimal/Inches/Millimeters  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194
Stud Size Chart  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194

Fibre Routing

F

IBER

R

UNNER

Routing Systems

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

195

12x4 

F

IBER

R

UNNER

Routing System Roadmap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196-197

Cable fills for 

F

IBER

R

UNNER

12x4 Cable Routing System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198

12x4

F

IBER

R

UNNER

Routing System Channel and Cover  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198

12x4

F

IBER

R

UNNER

Q

UIK

L

OCK

Coupler  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199

12x4 

F

IBER

R

UNNER

System Fittings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199-203

12x4 

F

IBER

R

UNNER

Mounting Brackets  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204-205

6x4 

F

IBER

R

UNNER

Routing System Roadmap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206-207

Cable fills for 

F

IBER

R

UNNER

6x4 Cable Routing System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208

6x4 

F

IBER

R

UNNER

Routing System Channel and Covers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208

6x4 

F

IBER

R

UNNER

Q

UIK

L

OCK

Coupler  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209

6x4 

F

IBER

R

UNNER

System Fittings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209-212

4x4 and 6x4 

F

IBER

R

UNNER

Mounting Brackets  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .213-215

Adapters to Other Systems  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216
4x4 

F

IBER

R

UNNER

Routing System Roadmap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218-219

Cable fills for 

F

IBER

R

UNNER

4x4 Cable Routing System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220

4x4 

F

IBER

R

UNNER

Routing System Channel and Covers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220

4x4 

F

IBER

R

UNNER

Q

UIK

L

OCK

Coupler  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221

4x4 

F

IBER

R

UNNER

System Fittings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221-226

F

IBER

R

UNNER

Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227

2x2 Routing System Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228-229
Cable fills for 

F

IBER

R

UNNER

2x2 Cable Routing System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230

2x2

F

IBER

R

UNNER

Routing System Channels and Cover  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231

2x2 

F

IBER

R

UNNER

Q

UIK

L

OCK

Coupler  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231

2x2 

F

IBER

R

UNNER

System Fittings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231

Fibre Duct

F

IBER

-D

UCT

Routing System

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

233

2x2 and 4x4 

F

IBER

-D

UCT

Routing Systems Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234-235

Cable Fills for 2x2 and 4x4 

F

IBER

-D

UCT

Routing System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236

2x2 and 4x4 

F

IBER

-D

UCT

Routing Systems  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236

F

IBER

-D

UCT

System Fittings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237-238

F

IBER

-D

UCT

Bend Radius Control Trumpet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .239

F

IBER

-D

UCT

Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .239

F

IBER

-D

UCT

Mounting Brackets  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240-241

P

ANDUCT

Type H - Hinged Cover Slotted Wall Wiring Duct  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242

P

ANDUCT

Type FL - Flexible Wiring Duct   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242

P

ANDUCT

Type G - Slotted Wall Wiring Duct  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .243

P

ANDUCT

Type G - Duct Wire Retainer  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245

P

ANDUCT

Type F - Duct Wire Retainers/Labelling Device  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245

PA

NDUCT

Type FS - Solid Wall Raceway  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246

PA

NDUCT

Type NNC - Halogen Free Metric Wiring Duct   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .247

Panduit-Pannet-html.html
background image

vii

T

ABLE OF

C

ONTENTS

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Fibre Duct (continued)

PA

NDUCT

Installation Tools  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248

PA

NDUCT

Accessories -Divider Wall  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248

PA

NDUCT

Duct Corner Strip with 25mm Bend Radius Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249

Bend Radius Control Trumpet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249

Panway Non-Metallic Surface Railway

P

ANWAY

Non-Metallic Surface Raceway

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

251

P

ANWAY

Office Furniture Raceway

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

252

Office Furniture Raceway Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253-254
Office Furniture Configurations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255-256
P

ANWAY

Office Furniture Raceway System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257

P

ANWAY

Office Furniture Raceway Fittings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257-259

Cable Fill Capabilities for Office Furniture  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .260

P

ANWAY

Cove Raceway

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

261

Cove Raceway Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .262-263
Cove Configurations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .264-265
P

ANWAY

Cove Raceway System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266

P

ANWAY

Cove Raceway Fittings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .267

Cable Fill Capabilities for Cove Raceway  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268

P

ANWAY

TG-70 Non-Metallic Surface Raceway

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

269

TG-70 Raceway Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270-271
TG-70 Configurations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272-273
P

ANWAY

TG-70 Surface Raceway System   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .274

P

ANWAY

TG-70 Raceway Fittings   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .275

P

ANWAY

TG-70 Raceway Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .276

Cable Fill Capabilities for TG-70 Raceway  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .277

P

ANWAY

T-70 & Twin-70 Non-Metallic Surface Raceway

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

279

T-70 Configurations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .282-283
Twin-70 Raceway Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .284-285
P

ANWAY

T-70 Surface Raceway System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286

P

ANWAY

T-70 Raceway Fittings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286-287

P

ANWAY

Twin-70 Surface Raceway System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .288

P

ANWAY

Twin-70 Raceway Fittings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289

P

ANWAY

T-70 & Twin-70 Raceway Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .290

Cable Fill Capabilities for T-70 Raceway  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .291
Cable Fill Capabilities for Twin-70 Raceway  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .292

P

ANWAY

T-45 Non-Metallic Surface Raceway

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

293

T-45 Raceway Roadmap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .294-295
T-45 Configurations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .296-297
P

ANWAY

T-45 Surface Raceway System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .298

P

ANWAY

Type T-45 Raceway Fittings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .299

Cable Fill Capabilities for T-45 Raceway  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300

P

ANWAY

LD Profile Non-Metallic Surface Raceway

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

301

LD2P10 Profile Raceway Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .302-303
LD2P10 Configurations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .304-305
LD Profile Raceway Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .306-307
LD Configurations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308-309
LDP Profile Raceway Roadmap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310-311
LDP Configurations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312
P

ANWAY

Type LD2P10 Multi-Channel Surface Raceway System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .313

Multi-Channel Fittings for LD2P10  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .313
P

ANWAY

LD Surface Raceway System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .314

P

ANWAY

LDP Surface Raceway System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315

P

ANWAY

LDS Surface Raceway System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .316

Method for Bending Type LDS Raceway (Low Voltage Applications)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .316
Standard Fittings for Low Voltage Applications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .317
One Inch Bend Radius Fittings for TIA/EIA Compliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318
Power Rated Fittings for Power to 600V – LDP / LDS / LD2P Raceway Only  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319
Raceway Adapters for LD Raceway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .320
Cable Fill Capabilities for LD Profile Raceway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .320

Panduit-Pannet-html.html
background image

viii

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

T

ABLE OF

C

ONTENTS

Cable Ties & Accessories

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

321

T

AK

T

Y

Hook & Loop Cable Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .322

T

AK

T

Y

Hook & Loop Cable Strips  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323

C

ONTOUR

-T

Y

Cable Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323

B

ELT

-T

Y

In-Line Cable Tie  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324

P

AN

-T

Y

Cable Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .325

P

AN

-T

Y

HALAR Cable Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326

P

AN

-T

Y

Clamp Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326

P

AN

-T

Y

Marker & Flag Cable Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327

HOT STAMPING - Custom Printed Cable Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327
D

OME

-T

OP

Barb Ty Cable Ties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .328

D

OME

-T

OP

Barb Ty Clamp Cable Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .328

D

OME

-T

OP

Barb Ty Marker & Flag Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .329

D

OME

-T

OP

Cable Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .329

Stackable Cable Spacer  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .330
Ergonomic Cable Tie Installation Tools  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .330
P

AN

-T

Y

Cable Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331-332

D

OME

-T

OP

Barb-Ty Cable Ties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .333

Parrallel Entry Cable Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .334
Hook & Loop Cable Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .335
T

AK

-T

Y

Hook & Loop Cable Tie Mounts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .336

4-Way Adhesive Backed Mounts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .336
Tie Mounts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337
Extra-Heavy Tie Mounts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337
Winged Push Mount  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337
J-M

OD

Cable Support System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .338-339

Adhesive Backed Cord Clips  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .340
C

LINCHER

Adjustable Releasable Clamp  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .340

Bevel Entry Clips  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .340
Cable Bundle Strap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .340
Latching Clips  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .341
Cable Holder  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .341
P

AN

-S

TEEL

Self-Locking Stainless Steel Cable Ties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .342

P

AN

-S

TEEL

W

AVE

-T

Y

Self-Locking Stainless Steel Cable Ties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .343

Patented Nylon 11 Selectively Coated Ties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .344
Optional Installation Tooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .344
P

AN

-W

RAP

Split Harness Wrap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .345

P

AN

-W

RAP

Installation Tool  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .345

Spiral Wrap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .345
Corrugated Loom Tubing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .346
Grommet Edging  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347
HSEC Thick Wall End Caps  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347
HSTTV Heat Shrink  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .348

Cable Ties & Accessories

Labelling and Administration

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

349

P

AN

T

HER

LS8 Hand-Held Thermal Printer and Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .350

Self-Laminating Label Cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .351
Part Number System for Wire/Cable Labelling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .351
Self-Laminating Labels for Laser/Ink Desktop Printers Supplied on 216mm x 279mm (US Letter Sheets)  . . . . . . . . . . . . . . . . . . . . . . . . .351
L

ABEL

C

ORE

Fibre Optic Cable Indentification System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .352

Self-Laminating Label Cassettes for use with 

L

ABEL

C

ORE

Fibre Optic Cable Indentification System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .352

General Component Label Cassettes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .353
U

LTIMATE

ID

Network Label Cassette  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .353

Network Component Label Cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354
E

ASY

-M

ARK

Labelling Software Version 3.0  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .355

CAD-C

ONNECT

Labelling Software  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .355

U

LTIMATE

ID

Network System Labelling Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .356

Labelling and Ådministration

TIA/EIA Standard Guide

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

357

TIA/EIA Standard Guide

Part Index

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

389-403

Part Index

Common Terms

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

371-385

Acronyms

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

386-388

Common Terms / Acronyms

Panduit-Pannet-html.html
background image

1

PANDUIT

solutions include; modular twisted pair and fibre optic connectors, zone cabling

systems, outlets, network rack systems, physical layer management systems, raceway systems,

fibre routing systems, network grounding systems, network cable ties and accessories and

network identification systems.

World-class quality

High performance and reliability

Upgradable, modular design

Support of emerging network requirements

Reduction in total cost of ownership

Designed to meet and exceed the latest
TIA/EIA  standards

S

YSTEM

O

VERVIEW

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

2

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

G

LOBAL

S

ERVICES AND

S

UPPORT

The 

PANDUIT

Network Connectivity Group offers the 

PANDUIT

Certified Designer (PCD) Programme – an

initiative designed to support the designer in providing high quality, state-of-the-art solutions in today's
rapidly evolving communications market.

PANDUIT

aims to develop a responsive and collaborative relationship with the certified designer. By

creating a relationship with our certified designers, we work together to specify best in-class cabling
solutions for each unique infrastructure application.

Specifying 

PANDUIT

products provides customers with a broad spectrum of integrated cabling components

that meet and surpass diverse national and multinational requirements. Around the world,

PANDUIT

leverages local expertise to customize our structured cabling solutions to the customer's needs.

PANDUIT

C

ERTIFIED

D

ESIGNER

P

ROGRAMME

The 

PANDUIT

Certified Installer (PCI) Programme was created to ensure that end-to-end 

PANDUIT

Cabling

Systems are installed properly and 100% tested to verify compliance with EIA/TIA industry standards. In
support of these objectives, systems installed by 

PANDUIT

Certified Installers are eligible for coverage

under the 

PANDUIT C

ERTIFICATION

P

LUS

™  

Warranty Programme.

PANDUIT

Certified Installers share our belief in providing high quality products and service.They have a

BICSI RCDD or equivalent on staff, who understands structured cabling requirements to ensure a proper
installation. In addition, theoretical and hands-on training is provided upon entrance into the PCI
Programme and repeated regularly to help 

PANDUIT

PCIs provide the best installation service in 

the industry.

The PCI Programme provides high-end design and installation companies with the training and support
required to install and maintain leading edge 

PANDUIT

Network Connectivity Solutions.What makes this

programme unique is the establishment of a global network of consistently trained, qualified
organisations to help you quickly and efficiently deploy a network infrastructure you can trust to support
your toughest applications.

PANDUIT

C

ERTIFIED

I

NSTALLER

P

ROGRAMME

The 

PACT

Programme brings together a community of best in class partners who share a vision – to

provide optimum business-focused network solutions based on a framework of open architecture,
designed specifically to support critical network applications and address unique vertical 
market considerations.

Under a traditional, vertically integrated business model, customers typically looked to one vendor to
satisfy all their requirements, from building services and network management to consultancy and
deployment. This approach not only limits choices,but also the level of product and technology innovation
available, ultimately restricting the customer's ability to compete and deliver a competitive return 
on investment.

PANDUIT

TM

is working with customers to develop application driven product solution sets, in support of

Voice over IP (VOIP), Ethernet to the home or office, and storage area networking deployment. Industry
standards help to ensure that solutions work together. However, the unified approach goes one step
further by testing the solutions for interoperability, functionality and performance, providing a further
assurance that the end-to-end system will function at an optimum level.

PACT

P

ROGRAMME

Panduit-Pannet-html.html
background image

3

The 

PANDUIT

Certified Systems Integrator (PCSI) Programme is designed to create a network of partners

who promote and design 

PANDUIT

solutions with other technologies, services and products.

This programme gives  security to end-users by offering them a single source integrator from the physical
to the application layers. PCSIs may provide additional assurance by offering the 

PANDUITC

ERTIFICATION

P

LUS

Warranty package on the systems they install.

The PCSI programme offers valuable training and certifications, presenting the Systems Integrator with
the opportunity to differentiate their services from the competition. Through this programme, Systems
Integrators can increase their scope of service,control of the network,and their value to the end user. This
exclusive programme is offered by 

PANDUIT

to first class Systems Integrators to deliver best in class

solutions to the end user.

PANDUIT 

C

ERTIFIED

S

YSTEMS

I

NTEGRATOR

P

ROGRAMME

The 

PANDUITC

ERTIFICATION

P

LUS

Warranty Programme provides a, complete product and system warranty

to guarantee high performance cabling systems that meet the demands of today and tomorrow.

The 

PANDUIT C

ERTIFICATION

P

LUS

Warranty Programme is an inclusive commitment that guarantees:

• 100% product coverage and support sponsored by 

PANDUIT

Corp.

• Warranty covering both COMPONENTS and LABOUR to repair or replace covered components 

and cable

• One point of contact for all cable and component questions
• Warranty direct from 

PANDUIT

to the end-customer

PANDUIT

ensures:

• Structuring Cabling System will support all current and all future network applications
• Structuring Cabling System will be free of defects in materials and workmanship
• Structuring Cabling System will meet or exceed applicable performance requirements defined in 

the Commercial Building Telecommunications Cabling Standards 

Ease of registration:

• Register warranty information at warranty@panduit.com using our electronic e-form process
• No minimum link requirement
• Technical staff available
• Allows freedom of cable choice

PANDUIT

SYSTEM WARRANTY

3

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

4

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

2

Fibre Connectors,

Enclosures and Patch Cords

(pages 89-129)

5

Racks and Cable

Management

(pages 131-157)

Fibre Routing

(pages 195-231)

Grounding and

Bonding

(pages 139-194)

1

2

Patch Panels,

Copper Patch Cords 

and Punchdowns

(pages 53-87)

4

3

4

3

6

7

PANDUIT

provides a wide variety of infrastructure solutions to support layouts such as these below.

To Workstation

or

Telecommunications

Room (IDF)

Telecommunications
Room

5

11

4

8

1

1

1

2

5

Panduit-Pannet-html.html
background image

5

U

LTIMATE

ID

System and

Work Area

(pages 31-43)

Cable Ties and

Accessories

(pages 321-348)

6

8

Zone Cabling

(pages 45-52)

9

Surface Raceway

(pages 251-320)

10

Labelling and

Administration

(pages 349-356)

11

Modules

(pages 19-30)

7

5

6

7

8

10

5

7

8

10

11

5

7

8

11

5

7

8

11

7

9

Workstation Area

4

5

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

6

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

NOTES

Panduit-Pannet-html.html
background image

7

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

C

OPPER AND

F

IBRE

L

INE

C

ARDS

S

OLUTION

Optimum Performance “Future Ready”

Best ROI for high bandwidth applications

High density solutions

Low installation cost

Panduit-Pannet-html.html
background image

TX

5500 CAT5e UTP cable

Part Number

Description

PUC5504LG-ED

UTP CAT5e general purpose cable. Conductors are 24 AWG construction with polyethylene insulation. 
The conductors are twisted in pairs and contained in a flame-retardant PVC jacket. Cable colour is 
Light Grey.

PUL5504DG-ED

UTP CAT5e Low Smoke Zero Halogen cable. Conductors are 24 AWG construction with polyethylene  
insulation. The conductors are twisted in pairs and contained in a flame-retardant, low smoke, halogen  
free jacket. Cable colour is Dark Grey.

M

INI

-C

OM

TX 5e UTP Module

Part Number

Description

CJ5E88TGAW*

CAT5e, 8 position, 8 wire universal module. Exceeds the CAT5e TIA/EIA 568.B.2.1 standard. Modules 
utilise patented 

G

IGA

-TX

Technology to optimise performance by reducing conductor untwist. 

Compatible with 

M

INI

-C

OM

Modular Patch Panels, Faceplate and Surface Mount Boxes. 

M

INI

-C

OM

CAT5e modules are available in 13 colours for easy identification and future move, adds and changes 
and can be clearly identified with optional labels and icons. 

(*) for module colour other than Artic White, replace "AW" with EI (Elec. Ivory), IW (Inter. White), IG (Inter. Grey), BL (Black) 
OR (Orange), RD (Red), BU (Blue), GR (Green), YL (Yellow), VL (Violet), BR (Brown), WH (White).

CAT5e Modular Plug and Termination Tool

MP588-M

P

AN

P

LUG

modular plug with tangle free latch. Terminate 24 AWG stranded cable or solid conductor 

with a max conductor insulation diameter of 1.02mm. 

M

INI

-C

OM

Modular Patch Panel & DP5e Data Punch Panel

Part Number

Description

CPP24WBL*

24 port patch panel supplied with 6 CFFP4 type snap-in faceplates which allow front access for easy  
moves, adds and changes. CPP24WBL occupies 1RU and is supplied with metric and imperial screws.

DP245E88TG

Universal 24 port patch panels specifically designed to comply with CAT5e performance requirements.  
DP5e patch panels adopt a printed circuit board design with a punch down termination system. Wiring  
scheme T568A and T568B are clearly identified on the back of the panel. Write-on area on the front of  
the panel allows clear identification for easy installation and future moves, adds and changes. 
PANDUIT

Punch Data patch panels are available in angled versions, with 24 or 48 ports.

(*) for modular panels with 32 or 48 port, replace "24" in the part number with either “32” or “48” accordingly. 
(**) for data patch panels with 48 or 96 port, replace "24" in the part number with either “48” or “96” accordingly

CAT5e UTP Patch Cords

Part Number

Description

UTPCH1M*

Enhanced CAT5e patch cords constructed with 24 AWG UTP stranded cable and enhanced modular plugs on
both ends. 

PANDUIT CAT5e patch cords exceed TIA/EIA 568-B 2.1 CAT5e standard requirements.

* For different metre lengths other than one metre replace "1" in the part number with 2 (two metres), 3 (three metres), 5 (five metres).
For patch cords with blue cable add suffix "BU" in the part number (i.e. UTPSP3MBU = 3 metres length, blue colour). Non 
standard length also available. Contact PANDUIT Customer Service for more details.

P

ATCH

L

INK

Horizontal Cable Managers

Part Number

Description

WMPH2E

2 RU horizontal cable manager with patented dual hinged cover for extra cable protection and pass 
through hole to allow cables to run from front to rear. Flexible fingers allow easy adds, moves and 
changes and help to maintain bend radius control. Mounts on a 19" rack or cabinet, front and rear.

WMPHF2E

Horizontal cable manager is as above, but front only.

WMPSE

1 RU horizontal cable manager with patented dual hinged cover for extra cable protection and pass 
through hole to allow cables to run from front to rear. Flexible fingers allow easy adds, moves and  
changes and help to maintain bend radius control. Mounts on a 19" rack or cabinet, front and rear.

WMPFSE

Horizontal cable manager is as above, but front only.

More options are available. Please contact PANDUIT Customer Service or visit www.panduit.com/emea

M

INI

-C

OM

Faceplates

Part Number

Description

CFPFS2SAW

45x45 two port faceplate kit with shutter door for dust and dirt protection.

CFPUKS2SWH

86x86 two port single gang faceplate with sloped insert and shutter doors. Provided with labels and  
label covers for easy identification.

CFPH4IW

70x114 four port horizintal faceplate. Blanks modules are available separately.

CHES3AW

55x55 three port faceplate with sloped inert. Supplied with screws, labels and label covers for easy identification.

CFPDS2SEW

77.1x50.4 two port faceplate with sloped insert and shutter door.

More faceplates are available in different types and colours. See PANDUITcatalogue for full details or contact PANDUIT

customer services.

*For termination tool, see page 30

Prime items appear in 

BOLD

.

Order number of pieces required, in multiples of Standard Package Quantity.

8

CAT5e Unshielded TX Solution

Panduit-Pannet-html.html
background image

9

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

TX

5500 CAT5e FTP CABLE

Part Number

Description

PFC5504LG-E

FTP CAT5e general purpose cable. Conductors are 24 AWG construction with polyethylene insulation. 
The conductors are twisted in pairs and wrapped in foil contained in a flame-retardant PVC jacket. 
Cable colour is Light Grey.

PFL5504DG-E

FTP CAT5e low smoke, zero halogen cable. Conductors are 24 AWG construction with polyethylene 
insulation. The conductors are twisted in pairs and wrapped in foil contained in a flame-retardant, low 
smoke, halogen free jacket. Cable colour is Dark Grey.

M

INI

-C

OM

TX-5e Shielded Module

Part Number

Description

CJS5E88TG

Category 5e 8 position, 8 wire 10G shielded jack module comes with a prefitted shield that provides a 360 
cable shield continuity maximising immunity to EMI. The wire cap optimises the termination, by reducing 
conductor untwist, for performance and repeatability. The cap is fitted with colour code information to assist 
termination to either T568A or B.

M

INI

-C

OM

Metal Patch Panel

Part Number

Description

CP16BL*

Designed specifically for shielded applications, 

PANDUIT

Metal patch panel accepts 

M

INI

-C

OM

Modules 

which snap directly into the panel.

CP24WSBL

Patch panels with strain relief bar, which provides cable management and improved bend radius protection. 
Write-on areas available for port identification. Mount to standard TIA/EIA 19" or 23" racks (optional 
extender bracket).

* for Metal Patch Panels with 24, 48, 72 or 96 ports replace “16” in the part number accordingly  (i.e.CP96BL = Metal Patch Panel 96 ports)

P

ATCH

L

INK

Horizontal Cable Managers

Part Number

Description

WMPH2E

2 RU horizontal cable manager with patented dual hinged cover for extra cable protection and pass through 
hole to allow cables to run from front to rear. Flexible fingers allow easy adds, moves and changes and help 
to maintain bend radius control. Mounts on a 19" rack or cabinet, front and rear.

WMPHF2E

Horizontal cable manager is as above but front only.

WMPSE

1 RU horizontal cable manager with patented dual hinged cover for extra cable protection and pass through 
hole to allow cables to run from front to rear. Flexible fingers allow easy adds, moves and changes and help 
to maintain bend radius control. Mounts on a 19" rack or cabinet, front and rear.

WMPFSE

Horizontal cable manager is as above but front only.

More options are available. Please contact PANDUIT Customer Service or visit www.panduit.com/emea

CAT5e Shielded Patch Cords

Part Number

Description

STPC1MBBL*

Shielded CAT5e Patch Cords with modular 

P

AN

-P

LUG

on both ends.

* For other metre lengths replace "1" in the part number with "2" (two metres), "3" (three metres), "5" (five 
metres) Non standard lengths also available. Contact PANDUIT Customer Service for more details.

CAT5e Shielded TX Solution

Panduit-Pannet-html.html
background image

TX6000 CAT6 UTP Cable

Part Number

Description

PUC6004LG-ED

UTP CAT6 general purpose cable. Conductors are 24 AWG construction with polyethylene insulation. 
The conductors are twisted in pairs and contained in a flame-retardant PVC jacket.  Accepts next 
generation application - tested to 350 MHz. Cable colour is Light Grey

PUL6004DG-ED

UTP CAT6 low smoke, zero halogen cable. Conductors are 24 AWG construction with polyethylene 
insulation. The conductors are twisted in pairs and contained in a flame-retardant, low smoke, halogen 
free jacket. Accepts next generation application. Cable colour is Dark Grey

M

INI

-C

OM

TX-6 P

LUS

Module

Part Number

Description

CJ688TG*

CAT6 

PLUS

, 8 position, 8 wire universal module. Exceeds the CAT6 TIA/EIA 568.B.2.1 standard. Utilises 

patented 

G

IGA

-TX

Technology to optimise performance by reducing conductor untwist. Compatible with 

M

INI

-C

OM

Modular Patch Panels, Faceplate and Surface Mount Boxes. 

M

INI

-C

OM

CAT6 

PLUS

modules 

are available in 13 colours for easy identification and  can be clearly identified with optional labels and icons

(*) for module colour other than Artic White, replace "AW" with EI (Elec.Ivory), IW (Inter. White), IG (Inter. Grey), BL (Black) OR 
(Orange), RD (Red), BU (Blue), GR (Green), YL (Yellow), VL (Violet), BR(Brown), WH (White)

M

INI

-C

OM

Snap-in Patch Panel

Part Number

Description

CPP24WBL

24 port patch panel supplied with 6 CFFP4 type snap-in faceplates. Allow front access for easy moves, 
adds and changes. CPP24WBL occupies 1RU and it is supplied with metric and imperial screws.

DP24688TG

48 Universal 24 port patch panels specifically designed to supply with CAT6 

PLUS

performance 

requirements. Write-on area allows for clear identification for easy installation and future moves, adds 
or changes. The 24 or 48 port panels are also available in angled versions

(*) For modular panels with 32 or 48 ports, replace “24” in the part number with either “32” or “48” accordingly.
(*) for data patch panels with 48 or 96 ports, replace “24” in the part number with either “48” or “96” accordingly.

CAT6 

PLUS

Patch Cords

Part Number

Description

UTPSP1M*

Constructed of next generation 24 AWG UTP stranded cable and enhanced modular plugs for superior 
performance plugs. Contacts are plated with gold for superior reliability. The new CAT6 

PLUS

patch cords exceed TIA/EIA 568-B 2.1 CAT6 standard.

* For different metre length other than one metre replace "1" in the part number with 2 (two metres), 3 (three metres), 5 (five 
metres). For patch cords with Blue cable add suffix "BU" in the part number (I.e. UTPSP3MBU = 3 metres length, blue colour). 
Non standard length also available. Contact PANDUIT

Customer Service for more details.

P

ATCH

-L

INK

Horizintal Cable Managers

Part Number

Description

WMPH2E

2 RU horizontal cable manager with patented dual hinged cover for extra cable protection and pass 
through hole to allow cables to run from front to rear. Flexible fingers allow easy adds, moves and 
changes and help to maintain bend radius control. Mounts on a 19" rack or cabinet, front and rear.

WMPHF2E

Horizontal cable manager is as above but only.

WMPSE

1 RU horizontal cable manager with patented dual hinged cover for extra cable protection and pass 
through hole to allow cables to run from front to rear. Flexible fingers allow easy adds, moves and 
changes and help to maintain bend radius control. Mounts on a 19" rack or cabinet, front and rear.

WMPFSE

Horizontal cable manager is as above but front only.

More options are available. Please contact PANDUIT

Customer Service or visit www.panduit.com/emea

M

INI

-C

OM

Faceplates

Part Number

Description

CFPFS2SAW

45x45 two port faceplate kit with shutter door for dust and dirt protection.

CFPUKS2SWH

86x86 two port single gang faceplate with sloped insert and shutter doors. Provided with labels and 
label covers for easy identification.

CFPH4IW

70x114 four port horizontal faceplate. Blanks modules are available separately.

CHES3AW

55x55 three port faceplate with sloped inert. Supplied with screws, labels and label covers for easy identification.

CFPDS2SEW

77.1x50.4 two port faceplate with sloped insert and shutter door.

More faceplates in different types and colours are available. See PANDUIT catalogue for full details or contact PANDUIT customer services.
*For termination tool, see page 30

10

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

CAT6 

PLUS Unshielded TX Solution

Panduit-Pannet-html.html
background image

11

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

CAT6 

PLUS

Modular Plug and Termination Tool

Part Number

Description

SP688-C

The 

TX6

PLUS

Modular Plug employs an Integral Pair Manager that locks conductors into place at 

the centre of the plug range. The new plug also features an integral strain relief and boot to maintain 
the proper bend radius on the patch cable to improve installed performance and lengthen the life of the 
patch cord. Sold in a bag of 100 pieces.

MPT5-8

MPT5-8 terminates both CAT5e and CAT6 

PLUS

plug types.

TX 6000 category 6 FTP Cable

Part Number

Description

PFC6004LG-ED

FTP CAT6 general purpose cable. Conductors are 24 AWG construction with polyethylene insulation. 
The conductors are twisted in pairs and wrapped in foil contained in a flame-retardant PVC jacket. 
Accepts next generation application - tested to 350 MHz. Cable colour is Light Grey.

PFL6004DG-ED

FTP CAT6 low smoke, zero halogen cable. Conductors are 24 AWG construction with polyethylene 
insulation. The conductors are twisted in pairs and wrapped in foil contained in a flame-retardant, low 
smoke, halogen free jacket. Accepts next generation applications. Cable colour is Dark Grey.

M

INI

-C

OM

TX-6

PLUS Shielded Module

Part Number

Description

CJS688TG

CAT6 

PLUS

jack module, 8 position, 8 wire with one piece shield. Exceed CAT6 TIA/EIA 568.B.2.1 

standard. Utilises patented 

G

IGA

-TX

Technology to optimise performance by reducing conductor 

untwist. Can be clearly identified with optional labels and icons. Compatible with 

M

INI

-C

OM

Metal 

Modular Patch Panels, Faceplates and Surface Mount Boxes.

M

INI

-C

OM

Metal Patch Panel

Part Number

Description

CP16BL*

Designed specifically for shielded applications, 

PANDUIT

Metal patch panel accept 

M

INI

-C

OM

Modules 

for STP applications, which snap directly into the panel.

CP24WSBL**

Patch panels with strain relief bar, which provides cable management and improved bend radius 
protection. Write-On areas available for port identification. Mount to standard TIA/EIA 19" or 23" racks 
(with optional extender bracket).

* for Metal Patch Panels with 24, 48, 72 or 96 ports replace 16 in the part number accordingly. (i.e.CP96BL = Metal Patch Panel 96 ports)

P

ATCH

-L

INK

Horizintal Cable Managers

Part Number

Description

WMPH2E

2 RU horizontal cable manager with patented dual hinged cover for extra cable protection and pass 
through hole to allow cables to run from front to rear. Flexible fingers allow easy adds, moves and 
changes and help to maintain bend radius control. Mounts on a 19" rack or cabinet, front and rear.

WMPHF2E

Horizontal cable manager is as above but mounts on a 19" rack or cabinet, front only.

WMPSE

1 RU horizontal cable manager with patented dual hinged cover for extra cable protection and pass 
through hole to allow  cables to run from front to rear. Flexible fingers allow easy adds, moves and 
changes and help to maintain bend radius control. Mounts on a 19" rack or cabinet, front and rear.

WMPFSE

Horizontal cable manager is as above but front only.

CAT6 Shielded Patch Cords

Part Number

Description

STP6X1MBBL*

Shielded Patch Cords for use with Mini-Com

TX-6

Shielded Modules. Patented tangle free latch 

prevents snags and provides easy release, saving time on frequent moves, adds and changes.

* For other metre length replace 1 in the part number with 2 (two metres), 3 (three metres), 5 (five metres). Non standard length 
also available. Contact PANDUIT Customer Service for more details.

CAT6 

PLUS Shielded TX Solution

Panduit-Pannet-html.html
background image

TX6 

10G

IG

Cable

Part Number

Description

PUL6X04WH-E

The UTP 10G Low Smoke Zero Halogen cable has a unique construction that suppresses Alien Crosstalk in 
a cable bundle, an important parameter of 10G Ethernet transmissions.The conductors are of a 23 AWG 
construction with polyethylene insulation. The cable colour is white and it comes supplied on 305m reels.

TX6 10G

IG

J

ACK

M

ODULE

Part Number

Description

CJ6X88TG**

8 position, 8 wire 10G jack module comes with a wire cap that optimises the termination, by reducing 
conductor untwist, for performance and repeatability. The cap is fitted with colour code information to 
assist termination to either T568A or B. 

** Substitute for different module colours:

WH = White

IW = Off White

AW = Artic white

RD = Red

EI = Electric Ivory

BU = Blue

IG = International Grey

GR = Green

BR = Brown

YL = Yellow

OR = Orange

VL = Violet

BL = Black

M

INI

-C

OM

P

ATCH

P

ANELS

Part Number

Description

These standard 19” rack mount panels accept the 

M

INI

-C

OM

™ modules which simply snap into place.

CPP24WBL

24 Port panel supplied with 6 CFFPL4 snap in faceplates.

CPP48WBL

48 Port panel supplied with12 CFFPL4 snap in faceplates

CPPL24WBL

24 Port panel supplied with labels and 6 CFFPL4 snap in faceplates.

CPPL48WBL

48 Port panel supplied with labels and 12 CFFPL4 snap in faceplates

Flat - DP6 

10G

IG

Punchdown Patch Panels

Part Number

Description

DP246X88TG

24 port flat punchdown panel

DP486X88TG

48 port flat punchdown panel 

Angled - DP6 

10G

IG

Punchdown Patch Panels

Part Number

Description

DPA246X88TG

24 port angled punchdown panel 

DPA486X88TG

48 port angled punchdown panel 

TX6 

10G

IG

Patchcords

Part Number

Description

UTP6X**M

The 10G UTP patchcords have been optimised to provide superior performance matching to the 10G 
jack module delivering high end system channel performance. The patchcords are supplied with white 
cable as standard

Add BU to the end of the part number for Blue patchcords i.e. UTP6X2.5MBU for a 2.5m blue patchcord.

** Substitute for different lengths from the following standard parts 0.5m, 1m, 1.5m, 2m, 2.5m, 3m, 5m and 7m.

12

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

TX6 10G UTP Solution

Panduit-Pannet-html.html
background image

13

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

TX6 

10G

IG

Cable

Part Number

Description

PSC7004LG-ED

FTP 10G General purpose PIMF cable. The conductors are of a 23 AWG construction with polyethylene
insulation. The conductors are twisted pairs with each pair in a metal foil and contained in a flame 
retardant PVC jacket. The cable colour is Light Grey and comes supplied on 500m reels.

PSL7004DG-ED

FTP 10G General purpose PIMF cable. The conductors are of a 23 AWG construction with polyethylene
insulation. The conductors are twisted pairs with each pair in a metal foil and contained in a flame 
retardant PVC jacket. The cable colour is Light Grey and comes supplied on 500m reels..

M

INI

-C

OM

Shielded Module

Part Number

Description

CJS6X88TG

8 position, 8 wire 10G shielded jack module comes with a prefitted shield that provides a 360 cable 
shield continuity maximising immunity to EMI. The wire cap optimises the termination, by reducing 
conductor untwist, for performance and repeatability. The cap is fitted with colour code information to 
assist termination to either T568A or B. 

M

INI

-C

OM

Metal Patch Panel

Part Number

Description

The 

M

INI

-C

OM

panels are specifically designed for shielded applications. The 

M

INI

-C

OM

modules 

simply snap into place.

CP16BL

16 Port, 1RU black panel

CP24BL

24 Port, 1RU black panel

CP48BL

48 Port, 1RU black panel

CP72BL

72 Port, 1RU black panel

CP96BL

96 Port, 1RU black panel

10G Shielded Patchcords

Part Number

Description

STP6X**MBBL

The 10G patchcords have been optimised to provide superior performance matching to the 10G jack 
module delivering high end system channel performance.

The pathccords are offered in coloured cable with black boots. For other cable colours replace the suffix with BU (Blue), 
GR (Green), RD (Red) and YL (Yellow).
** The patchcords are available in the following lengths, 1m, 1.5m, 2m, 2.5m, 3m, 5m and 7m. i.e. for a 2.5m cord with blue 
cable the part number is STP6X2.5MBBU

TX6 10G Shielded Solution

Panduit-Pannet-html.html
background image

14

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

O

PTI

J

ACK

Fibre Connectors

Part Number

Description

FJJGS9CBU

O

PTI

-J

ACK

small form factor, duplex singlemode 9/125 optical connector, field polish, accept 900n 

tight buffer and 3.0mm jacketed fibre. Includes a dust cup for superior protection. Blue housing and 
boots simplify singlemode identification

FJEPGS9CBU

O

PTI

-P

LUG

small form factor, duplex singlemode 9/125 optical plug, field polish, accept 900n tight 

buffer and 3mm jacketed fibre. Includes a dust cup for superior protection. Blue housing and boots 
simplify singlemode identification

FSCSBU

SC Fibre Optic connector singlemode, field polish, accept 900n tight buffer and 3.0mm jacketed fibre. 
Includes a dust cup for superior protection. Blue housing and boots simplify singlemode identification

FSTSABU

ST Fibre Optic connector singlemode, field polish, accept 900n tight buffer and 3.0mm jacketed fibre. 
Includes a dust cup for superior protection. Blue housing and boots simplify singlemode identification

FLCDSBU

LC duplex fibre optic connectorsingle mode 9/125. Terminate 1.6mm or 2.0mm jacketed cable and 
900n tight buffered fibre. Field polish termination. Blue housing and boots simplify singlemode identification

FLCSSBU

LC simplex fibre optic connector singlemode 9/125. Terminate 1.6mm or 2.0mm jacketed cable and 
900n tight buffered fibre. Field polish termination. Blue housing and boots simplify singlemode identification

Adapter Modules

Part Number

Description

CMSBUSCZ

SC simplex fibre adapter module with zirconia split sleeve for singlemode applications. Available in 
different colours.

CMDBUSCZ

SC duplex fibre adapter module with zirconia split sleeve for singlemode applications. Available in 
different colours.

CMDJLCZ

LC fibre adapter module with zirconia split sleeve for singlemode applications. Available in different colours.

CMDSLCZ

LC fibre adapter module supplied with Sr/Sr mini duplex singlemode with zirconia split sleeve. Available
in different colours.

CMSTZ

ST fibre adapter module supplied with zirconia split sleeve for singlemode applications. Available in 
different colours.

CMFCZ

FC fibre adapter module with zirconia split sleeve for singlemode applications. Available in different colours.

CMMJ

MTRJ fibre adapter module mounts on all 

M

INI

-C

OM

faceplates and boxes. Available in different colours.

FASSLCZBU-L

LC simplex singlemode fibre adapter Sr/Sr with zirconia split sleeves (adapter only).

FADSLCZBU-L

LC duplex singlemode fibre adapter Sr/Sr with zirconia split sleeves (adapter only).

FASSCZBU-L

SC simplex singlemode fibre adapter with zirconia split sleeves (adapter only).

FADSCZBU-L

SC duplex singlemode fibre adapter with zirconia split sleeves (adapter only).

FADJLCZBU-L

LC duplex singlemode fibre adapter Sr/Jr mini with zirconia split sleeves  (adapter only).

FASJLCZBU-L

LC simplex singlemode fibre adapter Sr/Jr with zirconia ceramic split sleeves (adapter only).

Fibre Patch Cords

Part Number

Description

OM3

O

PTI

-C

ORE

10 GIG multimode 50/125n Fibre Optic Patch Cords and Pigtails. Available in different 

lengths and types.

OM2

Fibre optic multimode and single patch cords and pigtails. Available in different lengths and types.

For more information on part numbers and prices please contact PANDUIT

Customer Services. Non standard lengths available.

Termination Kits

Part Number

Description

FJKITG

Standard fibre optic termination kit for field polish termination.

FJMVKIT

O

PTI

-J

ACK

pre-polished connectors termination kit with visual fault locator. Easy crimp and 100% 

guarantee of correct termination.

*For termination tool, see page 30

Condensed Fibre Solution Line Card / Singlemode

Panduit-Pannet-html.html
background image

15

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Fibre Adapters Panels

Part Number

Description

FAP6WBUDSC

Preloaded with 6 SC simplex multimode/singlemode adapters. Snaps quickly and simply in front of panel for 
ease of access to the back.

FAP8WST

Preloaded with 8 ST multimode/singlemode adapters. Snaps quickly and simply in front of panel for ease of 
access to the back.

FAP6WEIDSC

Preloaded with 6 SC duplex multimode/singlemode adapters. Snaps quickly and simply in front of panel for 
ease of access to the back.

FAP12EWST

Preloaded with 12 ST multimode/singlemode adapters. Snaps quickly and simply in front of panel for ease of 
access to the back.

FAP6WBUDLCZ

Preloaded with 6 LC duplex singlemode adapters. Snaps quickly and simply in front of panel for ease of 
access to the back.

FAP6WFC

Preloaded with 6 FC simplex multimode/singlemode adapters. Snaps quickly and simply in front of panel for 
ease of access to the back.

More Fibre Adapter Panels are available. Contact PANDUIT

Customer Services for more information.

Fibre Adapter Patch Panels

Part Number

Description

CFAPPBL1

Mounts on the front of FMT1. Accepts 4 fibre adapter panels.

CFAPPBL2

Mounts on the front of FMT2. Accepts 8 fibre adapter panels.

Fibre Mount Trays & Drawers

Part Number

Description

FMT's

Fibre mount trays available in 1 and 2 RU. Accept up to 4 fibre splice trays. Mount on 19" rack. Use front 
panel CFAPPBL1 or CFAPPBL2.

FMD's

Slide out drawers available in 1 and 2 RU. Accept up to 4 fibre splice trays. Mount on 19" rack. Accept up to 
8 fibre adapter panels.

FT1W's

Preloaded fibre trays available with 12 ST, 24ST, & 12 Duplex SC. Empty version with 24 modular ports is available.

Wall Mount Enclosure

Part Number

Description

FWME's

Wall mount enclosures for building to building connections, terminates outside plants to IFC cable. Small & 
secure can be virtually mounted anywhere. Available in 12, 24 or 48 ports. Preloaded version available.

Fibre Rack Mount Enclosures

Part Number

Description

FRME's

Mount on 19" rack to support up to 144 Sc, 96 ST or 144 FJ termination. Hold up to 3 splice trays and 12 
Fibre Adapter panels

HD Fibre Distribution System

Part Number

Description

TRENB's

One-piece welded construction racks to be used with 

O

PTI

-C

OM

HD enclosures. Optimise space and 

reduce global cost of installation. 

O

PTI

-C

OM

fibre optic distribution encloser provides a complete fibre 

management system. Different models available.

F

IBER

R

UNNER

Part Number

Description

FR's

F

IBER

R

UNNER

is the ultimate 

PANDUIT

fibre routing system. Developed to protect and segregate fibre cable 

running to and from telecommunication rooms and equipment rooms. Allows for a clean and tidy work 
environment, implement easy moves, adds and changes. A unique 

Q

UIK

L

OCK

coupler allows channels to snap 

together in less then 5 seconds reducing time and cost of installation. Full range available in 2x2, 4x4, 6x4 
and 12x4.

SA-FRVD01

F

IBER

R

UNNER

Installation Training DVD.

FRLT

F

IBER

R

UNNER

Layout tool v2.0 for easy design and configuration of 

PANDUIT 's F

IBER

R

UNNER

and 

F

IBRE

-D

UCT

Routing System in structured cabling design.

Condensed Fibre Solution Line Card / Singlemode

Panduit-Pannet-html.html
background image

16

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

O

PTI

P

LUG

Jack Connectors

Part Number

Description

FJJGM5CEI

O

PTI

-J

ACK

small form factor, duplex multi mode 62.5/125 or 50/125 connector, pot & polish, accept 

900n tight buffer and 3.0mm jacketed fibre. Includes a dust cup for superior protection. Ivory housing 
and boots simplify multi mode identification. Available in different colours

FJEPGM5CEI

O

PTI

-P

LUG

small form factor, duplex multi mode 62.5/125 or 50/125 fibre optic plug, pot & polish, 

accept 900n tight buffer and 3.0mm jacketed fibre. Includes two dust cups for superior protection.
Ivory housing and boots simplify multi mode identification. Available in different colours

FJJSMM5CEI

O

PTI

-J

ACK

small form factor, duplex multi mode 62.5/125 mechanical crimp connector, pre-polished, 

accepts 900n tight buffer and 3.0mm jacketed fibre. Exclusive crimp termination guarantees superior 
perfomance while reducing installation costs. Available in different colours

FJJSMM50CEI

O

PTI

-J

ACK

small form factor, duplex multi mode 50/125 mechanical crimp connector, pre-polished, 

accept 900n tight buffer and 3.0mm jacketed fibre. Exclusive crimp termination guarantees superior 
perfomance while reducing installation costs. Available in different colours

FJGCCEI

Adapter to mate two FJ duplex fibre optic multimode or single mode plugs. Not for use in Mini-Com surface 
mount boxes

Fibre Optic Connectors

Part Number

Description

FSCMM

SC fibre mechanical crimp connector multimode 62.5/125, factory pre-polished for a superior 
performance and lower installation costs. Available in red and black boots.

FSCMM50

SC fibre mechanical crimp connector multimode 50/125, factory pre-polished for a superior 
performance and lower installation costs. Available in red and black boots.

FSTMM

ST fibre mechanical crimp connector multimode 62.5/125, factory pre-polished for a superior performance 
and lower installation costs. Available in red and black boots. 

FSTMM50

ST fibre mechanical crimp connector multimode  50/125, factory pre-polished for a superior 
performance and lower installation costs. Available in red and black boots. 

FLCSMEI

LC simplex fibre optic connector multimode 62.5/125 or 50/125. Terminate 1.6mm or 2.0mm jacketed 
cable and 900n tight buffered fibre. Field polish termination.

FLCDMEI

LC duplex fibre optic connector multimode 62.5/125 or 50/125. Terminate 1.6mm or 2.0mm jacketed cable 
and 900n tight buffered fibre. Field polish termination.

More connectors can be ordered to fit different applications and needs. See Panduit catalogue or visit www.panduit.com for more information

Adapter Modules

Part Number

Description

CMDEISC

Module supplied with one SC multimode duplex fibre adapter with phosphor bronze split sleeves. 
Available in different colours.

CMSEISC

Module supplied with one SC multimode simplex fibre adapter with phosphor bronze split sleeves. 
Available in different colours.

CMDSLC

Module supplied with one LC Sr/Sr multimode duplex fibre optic adapter with phosphor bronze split 
sleeves. Available in different colours.

CMDJLC

Module supplied with one LC Sr/Jr multimode duplex fibre optic adapter with phosphor bronze split 
sleeves. Available in different colours.

CMDJLC

Module supplied with one LC Sr/Jr multimode duplex fibre optic adapter with phosphor bronze split 
sleeves. Available in different colours.

CMDBUSC

Module supplied with one SC duplex fibre adapter with phosphor bronze split sleeve - blue adapter -  
Available in different colour.

CMFC

Module supplied with one FC multimode fibre optic adapter with phosphor bronze split sleeves. 
Available in different colours.

CMBA

Module supplied with industry standard 75 or 50 Ohm BNC coupler. Available in different colours.

CMFSR

Module supplied with industry standard 75 Ohm self terminating F-Type coupler. Available in different colours.

CMBIW-X

Blank module compatible with Mini-com modular patch panels, faceplates and mount boxes. One 
position, reserves space for the future.

More adapter modules can be ordered to fit different applications and needs. See Panduit catalogue or visit www.panduit.com

Fibre Patch Cords

Part Number

Description

OM3 

O

PTI

-C

ORE

10 G

IG

multimode 50/125n Fibre Optic Patch Cords and Pigtails. Available in different length 

and types.

OM2

Fibre optic multimode and single patch cords and pigtails. Available in different length and types.

For more information contact Panduit Customer Services or visit www.panduit.com - Non standard lengths available.

Condensed Fibre Solution Line Cards / Multimode

Panduit-Pannet-html.html
background image

17

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Fibre Adapter Panels

Part Number

Description

FAP6WBUDSC

Preloaded with 6 SC duplex multimode/singlemode adapters. Snaps quickly and simply in front of 
panel for ease of access to the rear.

FAP8WST

Preloaded with 8 ST multimode/singlemode adapters. Snaps quickly and simply in front of panel for 
ease of access to the rear.

FAP6WEIDSC

Preloaded with 6 SC duplex multimode/singlemode adapters. Snaps quickly and simply in front of 
panel for ease of access to the rear.

FAF12WAGSCZ

Preloaded with 12 SC APC simplex multimode adapters. Snaps quickly and simply in front of panel for 
ease of access to the rear

FAP6WEIDLC

Preloaded with 6 LC duplex multimode adapters. Snaps quickly and simply in front of panel for ease of
access to the rear.

More Fibre Adapter Panels are available. For more information contact Panduit Customer Services or visit www.panduit.com

Fibre Adapter Patch Panels

Part Number

Description

CFAPPBL1

Mounts on the front of FMT1. Accepts 4 fibre adapter panels.

CFAPPBL2

Mounts on the front of FMT2. Accepts 8 fibre adapter panels.

Fibre Mount Trays & Drawers

Part Number

Description

FMT's

Fibre mount trays available in 1 and 2 RU. Accept up to 4 fibre splice trays. Mount on 19" rack. Use 
front panel CFAPPBL1 or CFAPPBL2.

FMD's

Slide out drawers available in 1 and 2 RU. Accept up to 4 fibre splice trays. Mount on 19" rack. Accept 
up to 8 fibre adapter panels.

FT1W's

Preloaded fibre trays and available with 12 ST, 24ST, 12 Duplex SC. Empy version with 24 modular 
ports is available.

Wall Mount Enclosure

Part Number

Description

FWME's 

Wall mount enclosures for building to building connections, terminates outside plants to IFC cable. Small and 
secure can be virtually mounted anywhere. Available in 12, 24 or 48 ports. Preloaded version available

Fibre Rack Mount Enclosures

Part Number

Description

FRME's

Mount on 19" rack to support up to 144 Sc, 96 ST or 144 FJ termination. Hold up to 3 splice trays and 
12 Fibre Adapter panels.

HD Fibre Distribution System / Fibre Runner

Part Number

Description

FR's

F

IBER

R

UNNER

is the ultimate Panduit fibre routing system. Developed to protect and segregate fibre 

cable running to and from telecommunication rooms and  equipment rooms. Allows for a clean and tidy
work invironment, implement easy moves, adds and changes. A unique QuikLock coupler allows 
channels to snap together in less then 5 second reducing time and cost of installation. Full range 
available in 2x2, 4x4, 6x4 and 12x4.

SA-FRVD01

F

IBER

R

UNNER

Installation Training DVD.  Play on multi region DVD player or region 1 player

FRLT

F

IBER

R

UNNER

Layout tool v2.0 for easy design and configuration of Panduit's 

F

IBER

R

UNNER

and 

F

IBER

-D

UCT

Routing System in structured cabling design

Termination kits

Part Number

Description

FJKITG

Standard fibre optic termination kit and consumable for field polish connectors

FJMVKIT

Opti-Jack Pre-Polished connectors' termination kit with Visual Fault Locator. Easy crimp and 100% 
guarantee of correct termination. 

FVFLKIT

Visual fault locator kit included FVFL ( visulal fault lacator ) and FVFLPC ( patch cord ) 

FVFL

Visual fault locator.

FVFLPC

Patch cord to connect FVFL to fibre connector. 

FLPKIT-W

Standard fibre optic termination kit and consumable for field polish LC connectors. Includes FHSCT
heat shrink curing tool 240 volts.  

Condensed Fibre Solution Line Cards / Multi mode

Panduit-Pannet-html.html
background image

18

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

NOTES

Panduit-Pannet-html.html
background image

19

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

M

ODULES

The

PANDUIT

Network Connectivity Group offers solutions for copper, fibre and audio video

cabling applications.

M

INI

-C

OM

modules exceed the latest TIA/EIA-568-B requirements for

maximum performance and reliability and are designed for fast moves, adds and changes.

Multiple module colours allow colour-coding for network segregation to accommodate your 

specific network strategy.

Copper modules include 

TX6

PLUS

,

TX5e

and Category 3 jack modules. Fibre optic adapter

modules include LC, SC, ST*, MT-RJ and FC versions. Audio video adapters are also available for

BNC, F-Type Connectors, RCA and S-Video applications.

*ST is a registered trademark of Lucent Technologies

Modules are interchangeable within 

PANDUIT

M

INI

-C

OM

outlets, boxes and patch panels

Copper TX Style Jack Modules feature 

G

IGA

-TX

Technology which optimises performance by
reducing conductor untwists along with reducing
installation expense. TX Style Jack Modules utilise a
forward motion termination, placing no impact on
critical internal components for maximum reliability

Punchdown and pass-through versions are available
for both RCA and S-Video modules

Fibre adapters are available with phosphor bronze or
zirconia ceramic split sleeves for use with
multimode or singlemode connectors and
patch cords

Panduit-Pannet-html.html
background image

20

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

Component Labels for M

INI

-C

OM

TX6

PLUS Jack Modules

M

INI

-C

OM

TX6

PLUS Jack Module

• Exceeds TIA/EIA-568-B.2-1 Category 6 and ISO11801 2nd

Edition Class E standard

• Each jack is 100% tested to ensure NEXT and RL

performance and is individually serialised for traceability

• Utilises patent-pending enhanced 

G

IGA

-TX

Technology

for jack terminations which optimises performance by
maintaining cable pair geometry and eliminating
conductor untwist

• No punchdown tool required; termination tool (EGJT)

ensures conductors are fully terminated by utilising a
smooth forward motion without impact on critical internal
components for maximum reliability

• Can be re-terminated a minimum of 10 times
• Off White termination cap designates Category 6 

PLUS

performance and provides a positive strain relief, helps
control cable bend radius and securely retains wires 

• Terminates 4 pair, 22 – 24 AWG, 100 ohm, solid or

stranded twisted pair cable 

• Termination cap is colour coded for T568A and T568B 

wiring schemes

• Accepts 6 and 8 position modular plugs without damage
• Can be clearly identified with optional labels and icons

‡ For other colours replace suffix IW (Off White) with EI (Electric Ivory), WH (White), IG (International Grey),
BL (Black), OR (Orange), RD (Red), BU (Blue), GR (Green), YL (Yellow) or VL (Violet).
Termination tool available on page 30.
To ensure optimal performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 PLUS components.

Compatible with 

M

INI

-C

OM

Modular Patch Panels, Faceplates and Surface Mount Boxes

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CJ688TGIW

Category 6, 8 position, 8 wire
universal module.

1

Off  White

1

50

Suggested Label Solutions for TIA/EIA-606-A Compliance

Module

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

All TX6

PLUS

Modules

C138X019FJJ

C138X019FJC

M

INI

-C

OM

TX6

PLUS Shielded Jack Module

• Exceeds TIA/EIA-568-B.2-1 Category 6 and ISO11801 2nd

Edition Class E standard

• Each jack is 100% tested to ensure NEXT and return loss

performance and is individually serialised for traceability

• Utilises patent-pending enhanced 

G

IGA

-TX

Technology 

for jack terminations which optimises performance 
by maintaining cable pair geometry and eliminating
conductor untwist

• No punchdown tool required; termination tool (EGJT)

ensures conductors are fully terminated by utilising a
smooth forward motion without impact on critical internal
components for maximum reliability

• Can be re-terminated a minimum of 10 times

• Off White termination cap designates Category 6

performance and provides a positive strain relief, helps
control cable bend radius and securely retains wires 

• Terminates 4 pair, 22 – 24 AWG, 100 ohm, solid or

stranded shielded twisted pair cable 

• Termination cap is colour coded for T568A and T568B

wiring schemes

• Integral shield with optional 4.75mm grounding tab

provides conductive path for grounding

• Accepts 6 and 8 position modular plugs without damage
• Can be clearly identified with optional labels and icons 

Termination tool available on page 30.
Shield grounding requires proper installation of shielded jack module and the use of shielded patch cords
and cable.
To ensure optimal performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 PLUS

components. Compatible with 

M

INI

-C

OM

Modular Patch Panels, Faceplates and Surface Mount Boxes.

Part Number

Part Description

No. of

Module
Spaces

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CJS688TG

Category 6, 8 position, 8 wire universal shielded module with
integral shield.

1

1

50

Panduit-Pannet-html.html
background image

21

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

M

INI

-C

OM

TX5e

Jack Module

• Exceeds TIA/EIA-568-B.2 Category 5e and ISO11801 2nd

Edition Class D standards

• Utilises patent-pending enhanced 

G

IGA

-TX

Technology

for jack terminations which optimises performance by
maintaining cable pair geometry and eliminating
conductor untwist

• No punchdown tool required; termination tool (EGJT)

ensures conductors are fully terminated by utilising a
smooth forward motion without impact on critical internal
components for maximum reliability

• Can be re-terminated a minimum of 10 times

• Red termination cap designates Category 5e performance

and provides a positive strain relief, helps control cable
bend radius and securely retains wires 

• Terminates 4 pair, 22 – 24 AWG, 100 ohm, solid or

stranded twisted pair cable 

• Termination cap is colour coded for T568A and T568B

wiring schemes

• Accepts 6 and 8 position modular plugs without damage
• Can be clearly identified with optional labels and icons

‡ For other colours replace suffix IW (Off White) with EI (Electric Ivory), WH (White), IG (International Grey),
BL (Black), OR (Orange), RD (Red), BU (Blue), GR (Green), YL (Yellow) or VL (Violet).
Termination tool available on page 30.
Compatible with 

M

INI

-C

OM

Modular Patch Panels, Faceplates and Surface Mount boxes.

Part Number

Part Description

No. of

Module
Spaces Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CJ5E88TGIW

Category 5e, 8 position, 8 wire universal
module.

1

Off

White

1

50

M

INI

-C

OM

TX5e

Shielded Jack Module

• Exceeds TIA/EIA-568-B.2 Category 5e and ISO11801 2nd

Edition Class D standards

• Each jack is 100% tested to ensure NEXT and return loss

performance and is individually serialised for traceability

• Utilises patent-pending enhanced 

G

IGA

-TX

Technology 

for jack terminations which optimises performance 
by maintaining cable pair geometry and eliminating
conductor untwist

• No punchdown tool required; termination tool (EGJT)

ensures conductors are fully terminated by utilising a
smooth forward motion without impact on critical internal
components for maximum reliability

• Can be re-terminated a minimum of 10 times

• Red termination cap designates Category 5e performance

and provides a positive strain relief, helps control cable
bend radius and securely retains wires 

• Terminates 4 pair, 22 – 24 AWG, 100 ohm, solid or

stranded shielded twisted pair cable 

• Termination cap is colour coded for T568A and T568B 

wiring schemes

• Integral shield with optional 4.75mm grounding tab

provides conductive path for grounding

• Accepts 6 and 8 position modular plugs without damage
• Can be clearly identified with optional labels and icons

Termination tool available on page 30.
Shield grounding requires proper installation of shielded jack module and the use of shielded 
patch cords and cable.
Compatible with

M

INI

-C

OM

Modular Patch Panels, Faceplates and Surface Mount Boxes.

Part Number

Part Description

No. of

Module
Spaces

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CJS5E88TG

Category 5e, 8 position, 8 wire shielded module with
integral shield.

1

1

50

Panduit-Pannet-html.html
background image

22

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 end www.panduit.com

Component Labels for M

INI

-C

OM

TX5e

Jack Modules

Suggested Label Solutions for TIA/EIA-606-A Compliance

Module

Part Number

Label for

P

ANTHER

LS8

Hand-Held Therman Printer

All 

TX5e

Modules

C138X019FJJ

C138X019FJC

I

NDUSTRIAL

N

ET

TX5e

Connectors

• IP67 sealed Industrial Ethernet Connectors
• Exceeds TIA/EIA-568-B.2 standard and ISO 11801 2nd

Edition, Category 5e standards

• Shielded and unshielded versions available
• Utilises 

PANDUIT

patented 

G

IGA

-TX

termination

technique for consistent, reliable terminations

• Bulkhead anti-rotation washer eliminates the potential for

module rotation

• Gasket and seal made of inert, chemically 

resistant material

• Connector components are made of high temperature 

rated material

• Tethered caps maintain IP67 seal during 

unmated connection

• Meets the specifications of the TIA and Open DeviceNet

Vendor Association (ODVA) joint draft for Sealed
Ethernet/IP RJ45 connectors 

• Compatible with leading switch manufacturers’ equipment 
• Jack module terminates 4-pair 24 to 22 AWG solid twisted

pair cable

• Plug terminated 24 gauge stranded or solid conductor with

maximum conductor insulation diameter of 1mm

IAECJ688TG

EGJT

MPI588T

CJI5E88T

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

I

NDUSTRIAL

N

ET

TX5e

Jack

CJI5E88T

Category 5e, 8 position, 8 wire industrial connector with
protective cover.

1

10

I

NDUSTRIAL

N

ET

TX5e

Plug

MPI588T

Category 5e industrial plug with protective cover.

1

10

I

NDUSTRIAL

N

ET

TX5e

Shielded Jack

CJSI5E88T

Category 5e, 8 position, 8 wire shielded industrial connector with
protective cover.

1

10

I

NDUSTRIAL

N

ET

TX5e

Shielded Plug

MPSI588T

Category 5e shielded industrial plug with protective cover.

1

10

Termination Tool

CGJT

Terminates 

G

IGA

-TX

style jack modules.

1

50

I

NDUSTRIAL

N

ET

TX6

Connectors

• IP67 sealed Industrial Ethernet Connectors
• Meets TIA/EIA-568-B.2 standard and ISO 11801 2nd

Edition, Category 6 standards

• Utilises 

PANDUIT

patented 

G

IGA

-TX

termination      

technique for consistent, reliable terminations

• Bulkhead anti-rotation washer eliminates the potential for

module rotation

• Gasket and seal made of inert, chemically resistant material
• Connector components are made of high temperature 

rated material

• Tethered caps maintain IP67 seal during 

unmated connection

• Meets the specifications of the TIA and Open DeviceNet

Vendor Association (ODVA) joint draft for Sealed Ethernet/IP
RJ45 connectors 

• Compatible with leading switch manufacturers’ equipment 
• Jack module terminates 4-pair 24 to 22 AWG solid twisted

pair cable

• Plug terminated 24 gauge stranded or solid conductor with

maximum conductor insulation diameter of 1mm

• UTP only

Part Number

Description

Std.

Pkg.

Qty

Std.
Ctn.
Qty.

I

NDUSTRIAL

N

ET

TX6

Jack

IAECJ688TG

Industrial Bulkhead Jack Category 6 IP67. 

1

10

Termination Tool

EGJT

Terminates Enhanced 

G

IGA

TX

style jack.

1

50

Panduit-Pannet-html.html
background image

23

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Self-Laminating Labels for IUTPCH I

NDUSTRIAL

N

ET

TX5e

Patch cords

IUTPCH*BL

Part Number

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.

Part Description

IUTPCH3BL

Category 5e UTP Patch Cord with 

I

NDUSTRIAL

N

ET

TX5e

Modular Plugs on both ends — with tethered caps.

10

1

Length*

3 ft.

IUTPCHNC3BL

Category 5e UTP Patch Cord with 

I

NDUSTRIAL

N

ET

TX5e

Modular Plugs on both ends — without tethered caps.**

10

1

3 ft.

ISTPCH1MBL

Category 5e STP Patch Cord with 

I

NDUSTRIAL

N

ET

TX5e

Modular Plugs on both ends — with tethered caps.

10

1

1M

ISTPCHNC1MBL

Category 5e STP Patch Cord with 

I

NDUSTRIAL

N

ET

TX5e

Modular Plugs on both ends — without tethered caps.**

10

1

1M

I

NDUSTRIAL

N

ET

TX5e

Patch cords

*Additional lengths:

Patch cords are available in 3, 5, 7, 10, 15 and 20 foot lengths. To order lengths other than 3 feet, substitute

the 3 in the part number (IUTPCH3BL) with the desired length (IUTPCH5BL for 5 foot length). Shielded patch cords are available 
in 1, 2, 3 and 5 metre lengths. To order lengths other than 1 metre, substitute the 1 in the part number (ISTPCH1MBL) with the 
desired length (ISTPCH3MBL for 3 metre length). Contact Customer Service for additional lengths. See back cover for phone 
number. **

I

NDUSTRIAL

N

ET

TX5e

Plug Tethered Cap available separately: Part Number IAEPTC.

IUTPCHNC*BL

For complete labelling solutions and product information, reference the Labelling and Administration section 
on pages 349-356 and www.panduit.com

Suggested Label Solutions for TIA /EIA-606-A Compliance

Laser/Ink Jet Desktop 

Printer Label

S100X150YAJ

S100X150VAC

P

ANTHER

LS8

Hand-Held Thermal Printer

• Bulkhead provides IP67 seal when mated to an IP67 plug

I

NDUSTRIAL

N

ET

Patch Cords are pre-terminated and 

provide IP67 seal when mated to IP67 bulkhead jacks

• Patch cords built with 62.5

—

m, multimode, industrial-grade 

jacketed fibre cable

• Ideal for daisy-chaining hardened industrial switches 

between IP66 rated enclosures

• Pigtails are ideal for routing fibre through conduit
• Patch cords are 100% factory tested for insertion loss
• Insertion loss data recorded for every multimode patch 

cord providing lifetime traceability to QC number, labelled 
on each patch cord

I

NDUSTRIAL

N

ET

TX5e

LC Fibre Connectors and Patch Cords

Part Number

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.

Part Description

IAEF617P-7PM1*

Industrial Ethernet Duplex Multimode 62.5

—

m LC to LC Patch Cord.

10

1

IAEF617P-NM1**

Industrial Ethernet Duplex Multimode 62.5

—

m LC to Pigtail.

10

1

IAEF7JMA‡

Industrial Ethernet LC Fibre Adapter Bulkhead.

10

1

‡Bulkhead includes duplex multimode LC adapter with phosphor bronze split sleeve.
*Available in 1, 2, 3, 10, and 20 metre lengths.
**Contact Customer Service for pigtail lengths and/or discreet length patch cords with LC fibre interface. 
See inside back cover for phone number.

IAEF617P-7PM1

IAEF7JMA

Panduit-Pannet-html.html
background image

24

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

I

NDUSTRIAL

N

ET

Ethernet Enclosure

• IP66 rated when used with one of the required gland 

plate options

• Accommodates populated or unpopulated gland plates

(sold separately — see table)

• 35mm DIN rail equipped for mounting of a 

hardened Industrial Ethernet switch and power supply:
Length 375mm

• Power supply included (115/230V to 24V DC) with built-in

circuit breaker (installation required)

• Vibration mitigating back plate for improved switch integrity
• Four welded mounting flanges for convenient and 

secure installation

• Optional fan/filter kit available for enclosures in 

high temperature environments; enclosure is IP54 
rated when the fan/filter kit is installed

• Enclosure supplied with a cable routing accessory 

kit for copper

• Optional fibre routing kit available for the addition 

of fibre uplinks (sold separately — see table)

• Enclosure latches are lockout capable and will

accommodate shackle diameters 7.94mm or smaller;

PANDUIT

lock part number PSL-3. For complete

lockout/tagout solutions and product information, 
refer to the 

PANDUIT

Lockout/Tagout Products 

Catalogue, SA-IDCB06, at www.panduit.com

Part Number

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.‡

Part Description

IAEIP66

Industrial Ethernet Enclosure. Accepts one gland plate
(required to achieve IP66 rating). Supplied with power supply
(115/230V to 24V d.c.) and accessories kit. 
Dimensions 470mm x 470mm x 203mm 

1

1

IAECGP

Industrial Ethernet Connector Gland Plate. Fully populated
with 14 bulkhead fittings, 14 internal enclosure patchcords
(IUEJGY) for 12 downlink ports and two copper uplink ports.

1

1

IAEBGP

Industrial Ethernet Blank Gland Plate. Use knock out tool
IEKO30 to customise plate hole placement of part CJI5E88T

I

NDUSTRIAL

N

ET

TX5e

Jack.

1

1

IAEFK54

Industrial Ethernet Fan/Filter Kit, 24V d.c. powered. 
Includes DIN rail mount thermostat. IP54 rated when
fan/filter kit is installed.

1

1

IAEPCBH

Industrial Ethernet Internal Enclosure Patch Cords/Bulkhead
Assembly. RJ45 Plug to 

I

NDUSTRIAL

N

ET

TX5e

Jack

Module. UTP, solid wire, 381mm in length. Used to connect
switch to gland mounted bulkhead.

10

1

IEKO30

Standard NEMA 30.5mm Knock Out Tool required to
customize unpopulated gland plate.

1

1

IAEFKSC

Industrial Ethernet Enclosure Fibre Uplink Kit.
Accommodates two fibre uplinks to switch. Includes all 
parts to maintain IP67 rating and SC to MT/RJ patchcord 
to terminate SC uplink to the MT/RJ port on switch.

1

1

IAEFKSP

Industrial Ethernet Enclosure Fibre Uplink Kit.
Accommodates two fibre uplinks to switch. Includes all 
parts to maintain IP67 rating, splice tray and pigtail to
terminate MT/RJ port on switch.

1

1

2b

3

2a

1

5b

6

5a

4

IAEIP66

CIFP1S

• Accept 

I

NDUSTRIAL

N

ET

TX5e

Jacks

(CJI5E88T or CJSI5E88T)

• Impact resistant for 

industrial environments

• Rear gasket provides tight seal
• IP67 seal is achieved when used 

with 

I

NDUSTRIAL

N

ET

connectivity

I

NDUSTRIAL

N

ET

Stainless Steel Faceplates

CIFP2S-2G

Part Number

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.‡

Part Description

CIFP1S

Vertical faceplate accepts one 

I

NDUSTRIAL

N

ET

TX5e

Jack.

10

1

CIFP2S-2G

Double gang, vertical faceplate accepts two 

I

NDUSTRIAL

N

ET

TX5e

Jacks.

10

1

"

Standard NEMA Knockout

Panduit-Pannet-html.html
background image

25

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

M

INI

-C

OM

M

INI

-J

ACK

Category 3 Jack Modules

• Patented lead frame termination style twists are maintained

to within 12mm

• No punchdown tool required, optional termination tool 

(CJT-X) ensures conductors are fully terminated

• Termination cap provides excellent strain relief, helps 

control cable bend radius and securely retains wires

• Clear, removable termination cap provides 

easy troubleshooting

• Terminates 4-pair 24 to 22 AWG 100 ohm solid 

unshielded twisted pair cable

• Accepts 6 and 8 position modular plugs without damage
• White coloured module base designates Category 

3 performance

• Can be clearly identified with optional labels and icons
• Compatible with 

M

INI

-C

OM

modular patch panels, 

faceplates and surface mount boxes

‡ For other colours replace suffix AW (Arctic White) with EI (Electric Ivory), WH (White), IG (International Grey) 
or BL (Black).

CJ88

CJ66U

CJ64

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CJ88AW

Category 3, 8 position, 8 wire universal module.
Termination cap is colour coded for T568A and
T568B wiring schemes.

1

Arctic
White

1

50

CJ66AW

Category 3, 6 position, 6 wire module.

1

Arctic
White

1

50

CJ64AW

Category 3, 6 position, 4 wire module.

1

Arctic
White

1

50

Component Labels for M

INI

-C

OM

M

INI

-J

ACK

Category 3 Jack Modules

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

Suggested Label Solutions for TIA/EIA-606-A Compliance

Module

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Therman Printer

All Cat 3 Modules

C138X019FJJ

C138X019FJC

M

INI

-C

OM

5-Way Binding Post Module

• Allows for easy installation of speaker wires, along with the ability

to reconfigure speaker locations with greater ease

• Accepts a variety of termination ends, including bare speaker wire

and banana plugs

• Gold plated and large metal contact area facilitates improved 

signal transmission

• Red or black strip available around collar of binding post clearly

designates right or left speaker connection

• Compatible with 

M

INI

-C

OM

modular patch panels, faceplates and

non-shuttered surface mount boxes

‡ For other colours, replace suffix IW (Off White) with EI (Electic Ivory) or WH (White).

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMBPRIW

Module supplied with one 5-way binding post
with red strip.

1

Off

White

1

10

CMBPBIW

Module supplied with one 5-way binding post
with black strip.

1

Off

White

1

10

M

INI

-C

OM

3.5mm Stereo Connector Module

• Solder-type termination accepts 22 AWG stereo wire or smaller

• Connector accepts male plug found on typical stereo headsets

• Insulation resistance of the connector exceeds 100m ohms at 

DC 500V

• Rated for DC 12V, 1A

• Compatible with 

M

INI

-C

OM

modular patch panels, faceplates and

surface mount boxes

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CM35MSSIW

Connector module supplied with one 3.5mm
stereo headset connector.

1

Off

White

1

10

‡ For other colours, replace suffix IW (Off White) with EI (Electic Ivory) or WH (White).

CMRPR

CMRPR

Panduit-Pannet-html.html
background image

26

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

M

INI

-C

OM

RCA 110 Punchdown Modules

• Terminate 24 to 22 AWG solid or stranded conductors
• Utilise Category 5 or higher network cable facilitating a

common, easy and cost effective cabling installation. 
Only 2 of the 8 network cable conductors need to be 
terminated per cable.

• Includes wire retention cap
• Compatible with 

M

INI

-C

OM

modular patch panels, 

faceplates and surface mount boxes

‡ For other colours replace suffix IW (Off White) with EI (Electric Ivory), WH (White), IG (International Grey) 
or BL (Black).

M

INI

-C

OM

BNC Coax Coupler Modules

• Accept BNC plugs
• Available in 50 and 75 ohm versions

• Compatible with 

M

INI

-C

OM

modular patch panels, 

faceplates and surface mount boxes

‡ For other colours replace suffix AW (Arctic White) with EI (Electric Ivory), WH (White), IG (International Grey) or
BL (Black).

M

INI

-C

OM

Self-Terminating F-Type Module

• Eliminates need for termination cap on connector
• Automatically puts 75 ohm load on cable run when cable 

is disconnected

• Reduces noise and interference on the line
• Compatible with 

M

INI

-C

OM

modular patch panels, 

faceplates and surface mount boxes

‡ For other colours replace suffix AW (Arctic White) with EI (Electric Ivory), WH (White), IG (International Grey) 
or BL (Black).

M

INI

-C

OM

F-Type Module

• Perfect for use in CATV applications

• Compatible with 

M

INI

-C

OM

modular patch panels, 

faceplates and surface mount boxes

‡ For other colours replace suffix AW (Arctic White) with EI (Electric Ivory), WH (White), IG (International Grey) or
BL (Black).

CJRR

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMBA75AW

Module supplied with industry standard 75 ohm
BNC coupler.

1

Arctic
White

1

10

CMBAAW

Module supplied with industry standard 50 ohm
BNC coupler.

1

Arctic
White

1

10

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMFSRAW

Module supplied with 75 ohm self-terminating 
F-Type coupler.

1

Arctic
White

1

10

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMFBAAW

Module supplied with 75 ohm industry standard
F-Type bulkhead coupler.

1

Arctic
White

1

10

Part Number

Part Description

No. of

Module
Spaces Colour‡

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CJRRIW

Module supplied with one RCA connector with
red insert.

1

Off

White

1

10

CJRYIW

Module supplied with one RCA connector with
yellow insert.

1

Off

White

1

10

CJRWIW

Module supplied with one RCA connector with
white insert.

1

Off

White

1

10

Panduit-Pannet-html.html
background image

27

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

M

INI

-C

OM

RCA Pass through Module

• Supplied with one RCA coupler

• Compatible with 

M

INI

-C

OM

modular patch panels, 

faceplates and surface mount boxes

‡ For other colours replace suffix AW (Arctic White) with EL (Electric Ivory), WH (White), IG (International Grey) 
or BL (Black).

M

INI

-C

OM

S-Video Pass-through Module

• Supplied with one 4 pin mini din coupler

• Compatible with 

M

INI

-C

OM

modular patch panels, 

faceplates and surface mount boxes

‡ For other colours replace suffix AW (Arctic White) with EI (Electric Ivory), WH (White), IG (International Grey) 
or BL (Black).

M

INI

-C

OM

S-Video Punchdown Module

• Terminates 24 to 22 AWG solid or stranded conductors
• Utilises Category 5 or higher network cable facilitating a

common, easy and cost effective cabling installation. 
Only 4 of the 8 network cable conductors needs to be 
terminated per cable

• Includes wire retention cap
• Compatible with 

M

INI

-C

OM

modular patch panels, 

faceplates and surface mount boxes

‡ For other colours replace suffix IW (Off White) with EI (Electric Ivory), WH (White), IG (International Grey) or 
BL (Black)
Optional punchdown termination tool available on page XX.

M

INI

-C

OM

Module Base for D-Subminiature Connectors

• Accepts 9 pin or 15 pin high density connector, male or

female, solder or crimp type

• Compatible with select 

M

INI

-C

OM

modular patch panels,

faceplates and surface mount boxes

‡ For other colours replace suffix AW (Arctic White) with EI (Electric Ivory), WH (White), IG (International Grey) 
or BL (Black).

CMRPR

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMRPRAW

Module supplied with one RCA pass-through
coupler with red insert

1

Arctic
White

1

10

CMRPYAW

Module supplied with one RCA pass-through
coupler with white insert.

1

Arctic
White

1

10

CMRPWAW

Module supplied with one RCA pass-through
coupler with white insert.

1

Arctic
White

1

10

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CJSVIW

Module supplied with one SVHS connector.

1

Off

White

1

10

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMSVCAW

Module insert supplied with one S-Video 
pass-through coupler.

1

Arctic
White

1

10

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMDBAW-X

Two position module base which accepts 
9 pin and 15 pin high density D-subminiature
connectors.

2

Arctic
White

10

100

Panduit-Pannet-html.html
background image

28

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

• TIA/EIA-604 FOCIS-10 compatible adapters
• Exceed TIA/EIA-568-B.3 requirements 
• Small form factor (SFF) duplex adapter design fits into

single module space

• Compatible with 

M

INI

-C

OM

products for

complete modularity

• Sr./Jr. (Senior/Junior) adapter modules are designed to

accept FOCIS-10 compatible senior LC connectors at
either end and FOCIS-10 junior LC connectors at the
inside end for inside the wall applications

• Choice of phosphor bronze or zirconia ceramic split sleeves to

fit specific network requirements; zirconia ceramic split sleeves
are required for singlemode applications

• Every adapter is laser marked with Q.C. number to assure

100% traceability

M

INI

-C

OM

LC Duplex Adapter Modules are commonly

used with 

M

INI

-C

OM

Faceplates and Surface Mount

Boxes

• LC Simplex and Duplex Adapters are also available

separately on page 98, and in patch panels or fibre adapter
panels to provide a complete LC system solution

M

INI

-C

OM

LC Sr./Jr. Fibre Optic Adapter Modules

CMDJLCZ

CMDJAQLC

CMDJLC

‡ For other colours replace suffix EI (Electric Ivory) or BU (Blue) with EI (Electric Ivory), BU (Blue), BL (Black),
IW (Off White), or AW (Arctic White). 

10G

IG

Adapters are available in black modules only.

Part Number

Part Description

No. of

Module
Spaces

Module

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

LC Sr./Jr. Multimode Fibre Optic Adapter Modules (Electric Ivory adapters)

CMDJLCEI

Module supplied with one LC Sr./Jr. SFF duplex
multimode fibre optic adapter (EI) with phosphor
bronze split sleeves.

1

Electric

Ivory

1

10

LC Sr./Jr. 10G

IG

Multimode Fibre Optic Adapter Modules (Aqua adapters)

CMDJAQLCBL

Module supplied with one LC Sr./Jr. 

10G

IG

SFF duplex multimode fibre optic adapter (AQ)
with phosphor bronze split sleeves.

1

Black

1

10

CMDJAQLCZBL

Module supplied with one LC Sr./Jr. 

10G

IG

SFF duplex multimode fibre optic adapter (AQ)
with zirconia ceramic split sleeves.

1

Black

1

10

LC Sr./Jr. Singlemode Fibre Optic Adapter Modules (Blue adapters)

CMDJLCZBU

Module supplied with one LC Sr./Jr. SFF duplex
singlemode fibre optic adapter (BU) with
zirconia ceramic split sleeves.

1

Blue

1

10

M

INI

-C

OM

MT-RJ Fibre Optic Adapter Modules

• TIA/EIA-604 FOCIS-12 compliant adapter
• Exceed TIA/EIA-568-B.3 requirements
• Compatible with 

M

INI

-C

OM

products for 

complete modularity

• Designed for multimode MT-RJ connectors and patch

cords

M

INI

-C

OM

MT-RJ Duplex Adapter Modules are 

commonly used with 

M

INI

-C

OM

Faceplates and 

Surface Mount Boxes

‡ For other colours replace suffix EI (Electric Ivory) with BL (Black), BU (Blue), IW (Off White), or AW (Arctic White).

Part Number

Part Description

No. of

Module
Spaces

Module

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMMJEI

MT-RJ multimode duplex fibre optic
adapter module.

1

Electric

Ivory

1

10

Panduit-Pannet-html.html
background image

29

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

M

INI

-C

OM

ST Fibre Optic Adapter Modules

• TIA/EIA-604 FOCIS-2 compatible adapters
• Exceed TIA/EIA-568-B.3 requirements
• Compatible with 

M

INI

-C

OM

products for 

complete modularity

• Choice of phosphor bronze or zirconia ceramic split sleeves

to fit specific network requirements; zirconia ceramic split
sleeves are required for singlemode applications

M

INI

-C

OM

ST Simplex Adapter Modules are commonly

used with 

M

INI

-C

OM

Patch Panels

• ST Simplex Adapters are also available in patch panels 

or fibre adapter panels to provide a complete ST
system solution

CMSTZ

‡ For other colours replace suffix EI (Electric Ivory) or BU (Blue) with EI (Electric Ivory), BU (Blue), BL (Black),
IW (Off White), or AW (Arctic White).

Part Number

Part Description

No. of

Module
Spaces

Module

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

ST Multimode Fibre Optic Adapter Modules

CMSTEI

Module supplied with one ST multimode fibre
optic adapter with phosphor bronze split sleeve.

1

Electric

Ivory

1

10

ST Singlemode Fibre Optic Adapter Modules

CMSTZBU

Module supplied with one ST singlemode fibre
optic adapter with zirconia ceramic split sleeve.

1

Blue

1

10

M

INI

-C

OM

FC Fibre Optic Adapter Modules

• TIA/EIA-604 FOCIS-4 compliant adapters
• Exceed TIA/EIA-568-B.3 requirements
• Compatible with 

M

INI

-C

OM

products for

complete modularity

• Choice of phosphor bronze or zirconia ceramic split sleeves to

fit specific network requirements; zirconia ceramic split sleeves
are required for singlemode applications

M

INI

-C

OM

FC Simplex Adapter Modules are commonly

used with 

M

INI

-C

OM

Patch Panels

• FC Simplex Adapters are also available in patch panels 

and fibre adapter panels to provide a complete FC 
system solution

CMFC

‡ For other colours replace suffix EI (Electric Ivory) or BU (Blue) with BL (Black), IW (Off White), or
AW (Arctic White).

Part Number

Part Description

No. of

Module
Spaces

Module

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FC Multimode Fibre Optic Adapter Modules

CMFCEI

Module supplied with one FC multimode fibre
optic adapter with phosphor bronze split sleeve.

1

Electric

Ivory

1

10

FC Singlemode Fibre Optic Adapter Modules

CMFCZBU

Module supplied with one FC singlemode fibre
optic adapter with zirconia ceramic split sleeve.

1

Blue

1

10

Panduit-Pannet-html.html
background image

30

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

M

INI

-C

OM

Blank Module

• Seals off openings in outlet to prevent tampering
• Compatible with 

M

INI

-C

OM

Modular Patch Panels,

Faceplates and Surface Mount Boxes

‡ For other colours replace suffix IW (Off White) with EI (Electric Ivory), WH (White), IG (International ) or 
BL (Black).

Part Number

Part Description

No. of

Module
Spaces Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMBIW-X

One position, reserves space for future use.

1

Off

White

10

50

Module Termination Tools

CGJT

CJT-X

CJAST

CWST

AVPDB

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

EGJT

Terminates Enhanced 

G

IGA

-

TX

style jack.

1

50

CGJT

Terminates 

G

IGA

-TX

Style Jack Modules.

1

50

CJT-X

Terminates 

M

INI

-C

OM

M

INI

-J

ACK

Jack  Modules.

10

50

CWST

Copper wire snipping tool, cuts conductors flush for
improved performance.

1

CJAST

Adjustable, single handed cable jacket stripping tool, strips outer jacket
of 4-pair UTP and ScTP cable.

1

AVPDB

Audio/Video Punchdown Base used to assist in terminating 

M

INI

-C

OM

S-Video and RCA punchdown modules.

1

50

EGJT

Panduit-Pannet-html.html
background image

31

W

ORK

A

REA

O

UTLET

S

OLUTIONS

The 

PANDUIT

Network Connectivity Group offers the market's most complete selection of

communications outlets as part of the 

P

AN

-N

ET

Network System offering. Count on

PANDUIT

to streamline and support your entire infrastructure.

Work Area Outlet products provide a broad range of solutions that are easily installed  and offer

absolute modularity. All products provide an aesthetically pleasing solution that will

compliment all types of work areas (office, schools, factories, etc.).

Completely modular, accepting all 

M

INI

-C

OM

Modules

for copper and  fibre applications

Superior design provides lower profile, higher density
outlet products, creating a cost effective solution for
easy moves, adds and changes

Outlet solutions consist of a variety of faceplate styles
and sizes

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

32

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

UK Sloped Shuttered Faceplate Kits

• Individual modules snap in and out of 

provided insert

• Single or double gang configurations

• Excellent for copper and fibre applications

• Shutters protect modules when not in use

Supplied with mounting screws, labels and label holder.

M

INI

-C

OM

UK Bezels

• Individual modules snap in and out

• Module inserts are front releasable

• Single or double gang configurations

• Accept all 1/2 size module inserts

Supplied with mounting screws, labels and label holder.

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

U.K. 86 x 86mm Single Gang Bezel

CBUKAW

86 x 86mm single gang bezel accepts one 1/2 size
module insert.

Arctic White

1

10

CBUKIW

Off White

1

10

U.K. 86 x 146mm Double Gang Bezel

CBUKAW-2G

86 x 146mm double gang bezel accepts two 1/2 size
module inserts.

Arctic White

1

10

CBUKIW-2G

Off White

1

10

CBUKWH-2G

White

1

10

M

INI

-C

OM

UK Faceplates

CFPUKS2S

CFPUKS4S-2G

CBUK

CBUK-2G

UK Sloped Faceplates

• Economical one piece design

• Excellent for copper and fibre applications

• High density, low profile solution

• Minimal depth required behind the faceplate

CFPUKS2B

CFPUKS3

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

2 Module Space, U.K. 86 x 86mm Single Gang Faceplate Kit

CFPUKS2SAW

86 x 86mm single gang bezel and one 1/2 size
sloped shuttered module insert. Depth to rear of
modules: 18.0mm

Arctic White

1

10

CFPUKS2SIW

Off White

1

10

CFPUKS2SWH

White

1

10

4 Module Space, U.K. 86 x 146mm Double Gang Faceplate Kit

CFPUKS4SAW-2G

86 x 146mm double gang bezel and two 1/2 size
sloped shuttered module insert. Depth to rear of
modules: 18.0mm

Arctic White

1

10

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

2 Module Space, U.K. 86 x 86mm Single Gang Sloped Faceplate

CFPUKS2BAW

86 x 86mm single gang faceplate holds up to two
M

INI

-C

OM

Connector Modules. Supplied with

mounting screws and CMB blank module. Depth to
rear of modules: 12.7mm

Arctic White

1

10

CFPUKS2BIW

Off White

1

10

CFPUKS2BWH

White

1

10

3 Module Space, U.K. 86 x 86mm Single Gang Sloped Faceplate

CFPUKS3AW

86 x 86mm single gang faceplate holds up to three
M

INI

-C

OM

Connector Modules. Supplied with

mounting screws. Depth to rear of modules: 12.7mm

Arctic White

1

10

CFPUKS3IW

Off White

1

10

Panduit-Pannet-html.html
background image

33

UK Outlet Accessories

• Inserts accept all 

M

INI

-C

OM

single 

position modules

• Excellent for copper and fibre applications

• Mounts to standard LJU6C openings with

22.3mm x 36.9mm dimensions

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

1 Module Space, U.K. LJU6C Unshuttered Module

CM6CAW-X

Unshuttered module snaps into standard UK LJU6C
floor box mounting plates, faceplates and patch
panels and holds a single 

M

INI

-C

OM

Connector

Module. Depth to rear of modules: 29.0 mm

Arctic White

10

50

1 Module Space, U.K. LJU6C Shuttered Module

CM6CSAW-X

Shuttered module snaps into standard UK LJU6C
floor box mounting plates, faceplates and patch
panels and holds a single 

M

INI

-C

OM

Connector

Module. Depth to rear of modules: 29.0 mm

Arctic White

10

50

CM6CAW

CM6CSAW

25 x 50 Euro-Mode Shuttered Adopter Module

• Accepts all 

PANDUIT

M

INI

-C

OM

Modules

STP and UTP (Category 5e and Category 6)

• Shutter door keeps connectors free from any

dust and dirt

• Suitable for both copper and fibre applications

• Dimensions: 25 x 50mm - 

Colour: Arctic White (AW)

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

25 x 50 Euro-Mode Shuttered Adopter Module

CM6CESAW-X

Euro-mode Adopter 25mm x 50mm Accepts all 
M

INI

-C

OM

modules

Arctic White

10

50

CM6CESAW

German Faceplate and Adapter Kits

• Individual modules snap in and out

• 2 or 3 module space solutions available

• Excellent for fully shielded copper cabling and

fibre applications

• Adapter kit fits inside 80 x 80mm standard

frame and 

PANDUIT frame (FCFP)

• Front releasable inserts provided

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

3 Module Space, German 80 x 80mm Faceplate Kit

CFPE3AW

80 x 80mm bezel and one 50 x 50mm three module
space sloped faceplate. Supplied with mounting
screws, metal mounting plate, label and label holder.
Depth to rear of modules: 16mm

Arctic White

1

10

CFPE3IW

Off White

1

10

CFPE3PW

Polar White

1

10

2 Module Space, German 50 x 50mm Faceplate Kits

CFPAGF2AW

50 x 50mm adapter and one 1/2 size flat module
insert. Supplied with mounting screws and metal
mounting plate. Depth to rear of modules: 32mm

Arctic White

1

10

CFPAGF2IW

Off White

1

10

CFPAGF2PW

Polar White

1

10

CFPAGS2AW

50 x 50mm adapter and one 1/2 size sloped module
insert. Supplied with mounting screws and metal
mounting plate. Depth to rear of modules: 23.6mm

Arctic White

1

10

CFPAGS2IW

Off White

1

10

CFPAGS2PW

Polar White

1

10

CFPAGS2SAW

50 x 50mm adapter and one 1/2 size sloped
shuttered module insert. Supplied with mounting
screws and metal mounting plate. Depth to rear of
modules: 23.6mm

Arctic White

1

10

CFPAGS2SIW

Off White

1

10

CFPAGS2SPW

Polar White

1

10

M

INI

-C

OM

German Faceplates

CFPE3

CFPAGF2

++no other colours are available as standard part

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

34

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

German Floor Box Sloped Faceplate

• Individual modules snap in and out

• Highest density, 100% modular, floor box 

faceplate available

• Excellent for fully shielded copper cabling and

fibre applications

• One part provides a variety of different 

configurations with built in score lines to break
away plastic as needed

• Can be used with a variety of German 

floor boxes

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

3 Module Space, German Floor Box Sloped Faceplate

CFPGFB3BL

Floor box sloped faceplate holds up to three 
M

INI

-C

OM

Connector Modules. Supplied with label

and label holder. Depth to rear of modules: 18mm

Black

1

10

M

INI

-C

OM

German Bezels and Adapters

• Bezel accepts all 50 x 50mm faceplates 

and adapters

• Adapter accepts all 1/2 size module inserts

• Adapter allows front access to connectors 

and cables

• Adapter fits most local 80 x 80mm 

bezels (contact customer service for 
specific applications)

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

German 80 x 80mm Bezel

FCFPAW

80 x 80mm bezel accepts all 50 x 50mm faceplates and
adapters shown in this section.

Arctic White

1

10

FCFPIW

Off White

1

10

FCFPPW

Polar White

1

10

German 50 x 50 Adapter

CBAGAW

50 x 50mm adapter accepts one 1/2 size module insert
and mounts into 80 x 80mm bezel. Supplied with
mounting screws, metal mounting plate and label holder.

Arctic White

1

10

CBAGIW

Off White

1

10

CFPGFB3

FCFP

CBAG

German Faceplate for Ackermann GB2 Sub Box

• Designed to fit into the Ackermann Floor 

Box 30354-A and 30354-B

• Complete modularity - accepts all 

PANDUIT

M

INI

-C

OM

Modules STP and UTP (category

5e and Category 6)

• A sloped profile help cables to jeep 

optimum bend radius control for maximum
network performance

• Shutters doors located on each port help to

maintain contacts clear from dust and dirt 

• Available in two different versions, 3, 6 or 9

ports, according to the density required 
labels and label covers, placed right in
direction of the ports, allows clear and 
durable identification

• Built-in score line instantly convert faceplate

from 6 ports to a 3 port density

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

German Faceplate for Ackermann GB2 Sub Box

CFPGAS3SBL

M

INI

-C

OM

3 position sloped faceplate for use with

Ackermann sub box 30354-A

M

INI

-C

OM

6 position sloped faceplate for use with

Ackermann sub box 30354-A

Black

Black

1

1

10

10

CFPGAS6SBL

M

INI

-C

OM

9 position sloped faceplate for use with

Ackermann sub box 3055A+B

CFP6AS9SBL

Black

1

10

CFP6AS9SBL

CFPGAS3SBL

Panduit-Pannet-html.html
background image

35

M

INI

-C

OM

French Faceplate Kits

• Module inserts are front releasable

• Accept all 1/2 size module inserts

• Excellent for copper and fibre applications

• Can be mounted horizontally or vertically

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

2 Module Space, French 45 x 45mm Faceplate Kits

CFPFF2AW

45 x 45mm adapter and one 1/2 size flat module insert.
Depth to rear of modules: 26mm

Arctic White

1

10

CFPFS1SAW

French adapter 45 x 45. Accepts all 

M

INI

-C

OM

modules

Artic White

1

10

CFPFS2AW

45 x 45mm adapter and one 1/2 size sloped module
insert. Depth to rear of modules: 19mm

Arctic White

1

10

2 Module Space, French 45 x 45mm Faceplate Kit with STP Connectors

CS2FPAW

45 x 45mm adapter with one 1/2 size sloped shuttered
insert and two CJS588.

Arctic White

1

10

2 Module Space, French 45 x 45mm Faceplate Kit with UTP Connectors

C2FPAW

45 x 45mm adapter with one 1/2 sloped shuttered insert
and two CJ588.

Arctic White

1

10

M

INI

-C

OM

French Faceplates

French Adapter

• Module insers are front releasable

• Accept all 1/2 size module inserts

• Excellent for copper and fibre applications

• Can be mounted horizontally or vertically

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

French 45 x 45mm Adapter

CBFAW

45 x 45mm adapter accepts one 1/2 size module insert.

Arctic White

1

10

CBF

CFPFF2

CS2FP

C2FP

German Faceplates

• Individual modules snap in and out

• 100% modular

• Excellent for fully shielded copper cabling and

fibre applications

• Shuttered and unshuttered versions available

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

3 Module Space, German 55 x 55mm Sloped Faceplate

CHES3AW

55 x 55mm sloped faceplate holds up to three 
M

INI

-C

OM

Connector Modules. Supplied with mounting

screws, metal mounting plate, label and label holder. 
Depth to rear of modules: 26mm

Arctic White

1

10

CHES3IW

Off White

1

10

CHES3PW

Polar White

1

10

CHES3

CFPFS2SAW

45 x 45mm adapter and one 1/2 size sloped shuttered
module insert. Depth to rear of modules: 19mm

Arctic White

1

10

Standard Colour:

PW

Polar White

Black

BL

SG

Silk Grey

Colour shown

Colours shown are approximate 

is approximate. 

Other colours available:

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

WH

White

IW

Int. White

AW

Arctic White

Panduit-Pannet-html.html
background image

36

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

M

INI

-C

OM

Italian Classic Series Faceplates

• Compliments modern office workspace

• Individual modules snap in and out

Part Number

Part Description

Colour

2 Module Space Horizontal Single Gang Faceplate

70 x 114mm horizontal faceplate holds up to two 
M

INI

-C

OM

Connector Modules. Supplied with mounting

screws. Fixing centre: 83.5mm screws. Depth to rear of
Modules: 29mm

Arctic White

1

10

CFPH2BL

Black

1

10

CFPH2IW

Off White

1

10

CFPH2WH

White

1

10

2 Module Space - Horizontal

CFPH4AW

70 x 114mm horizontal faceplate holds up to four 
M

INI

-C

OM

Connector Modules. Supplied with mounting

screws. Fixing centre: 83.5mm screws. Depth to rear of
Modules: 29mm

Arctic White

1

10

CFPH4BL

Black

1

10

CFPH4IW

Off White

1

10

CFPH4WH

White

1

10

M

INI

-C

OM

Italian Designer Series Faceplates

CFPH2

CFPH4

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CFPH2AW

Italian Vimar Adapter

• Individual modules snap in and out 

• Quick and easy installation

• Same faceplate frame for data outlets as

electrical outlets

• Adapters are front releasable

• Highest density, 100% modular solution

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CVIA1GY-X
CVIA1WH-X

Adapter holds on one 

M

INI

-C

OM

Module in a Vimar IDEA

Series Faceplate.

Arctic
White

10

50

Italian Gewiss Adapter

• Individual modules snap in and out 

• Same faceplate frame for data outlets as

electrical outlets

• Highest density, 100% modular solution

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Adapter for GEW.55 Faceplate Frame 70 x 50mm

CGAGY-X

Adapter holds on one 

M

INI

-C

OM

Module in a Gewiss

Playbus Series Faceplate.

Grey

10

50

4 Module Space Horizontal Single Gang Faceplate

CFPH4AW

70 x 114mm horizontal faceplate holds up to four 
M

INI

-C

OM

Connector Modules. Supplied with mounting

screws. Fixing centre: 83.5mm screws. Depth to rear of
Modules: 29mm

Arctic White

1

10

CFPH4BL

Black

1

10

CFPH4IW

Off White

1

10

CFPH4WH

White

1

10

4 Module Space Horizontal with icon slots and label/label cover

CFPHSL4AW

70 x 114mm horizontal faceplate holds up to four 
M

INI

-C

OM

Connector Modules. Supplied with mounting

screws. Fixing centre: 83.5mm screws. Depth to rear of
Modules: 29mm

Arctic White

1

10

CFPHSL4IW

Black

1

10

CFPHSL4PW

Off White

1

10

CFPHS2

CFPHS2

Panduit-Pannet-html.html
background image

37

Switzerland Faceplate

• Individual modules snap in and out

• Highest density, 100% modular solution of 

its design

• Excellent for copper and fibre applications

• Releasable from front side

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

3 Module Space, Switzerland 37.5 x 63mm Faceplate

CFPCH3AW

37.5 x 63mm faceplate holds up to three 

M

INI

-C

OM

Connector Modules. Depth to rear of Modules: 28.6mm

Arctic White

1

10

M

INI

-C

OM

Switzerland Bezel

• Inserts are front releasable

• Accepts all 1/2 size module inserts

• Excellent for copper and fibre applications

• Can be mounted horizontally or vertically

• Fits standard Swiss outlet boxes

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Switzerland 64mm Diameter Bezel

CBCHAW

64mm diameter bezel accepts one 1/2 size module insert. Arctic White

1

10

M

INI

-C

OM

Switzerland Faceplate

M

INI

-C

OM

Denmark Sloped Faceplates

Denmark Sloped Faceplate Kits

• Individual modules snap in and out

• Inserts are front releasable

• Sloped design protects cable bend radius

• Excellent for copper and fibre applications

• High strength mounting method

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

2 Module Space, Denmark Unshuttered Faceplate Kit

CFPDS2SG

Denmark 77.1 x 50.4mm faceplate with one sloped 1/2
size module insert holds up to two Mini-Com Connector
Modules. Depth to rear of modules: 17mm

Silk Grey

1

10

CFPDS2WH

White

1

10

2 Module Space, Denmark Shuttered Faceplate Kit

CFPDS2SSG

Denmark 77.1 x 50.4mm faceplate with one sloped
shuttered 1/2 size module insert holds up to two Mini-Com
Connector Modules. Depth to rear of modules: 17mm

Silk Grey

1

10

CFPDS2SWH

White

1

10

CFPDS2

CFPDS2S

O

PUS

66

Denmark adapters for 

C

LIC

LINE

and 

O

PUS

66

• Individual modules snap in and out

• Inserts are front releasable

• Sloped design protects cable bend radius

• Excellent for copper and fibre applications

• High strength mounting method

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

2 Module Space, Denmark Unshuttered Faceplate Kit

CHLK66S2S

C

LIC

’L

INE

Adapter

EW or NG

1

10

CHLKCLS2S

EW or NG

1

10

C

LIC

LINE

O

PUS

66

Adapter

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

38

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

• Easily mounted on both 

G

ALEA

and 

V

ALENA

faceplates

• Allows for all 

PANDUIT

UTP and 

FTP modules to become part of the 
network infrastructure

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CGVA2BL

G

ALEA

and 

V

ALENA

Adapter

Arctic White

1

10

Adapter for legrand 

G

ALEA

V

ALENA

faceplates

• Design to be used with Thorsman Perimeter

Trunking

• Can be clearly identified with label and label

cover

• Individual modules snap in and out

• One piece snap on mounting

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Thorsman Perimeter Trunking Faceplates

CFPTS4AW

Sloped faceplate holds up to four 

M

INI

-C

OM

Modules.

To be used with Thorsman Plastic trunking. Depth to
rear of module (copper): 11.43mm

Arctic White

1

10

European 

White

1

10

Thorsman* Perimeter Trunking Faceplates

CFPTS4

CGVA2BL

Sloped faceplate holds up to four 

M

INI

-C

OM

Modules.

To be used with Thorsman Plastic or metal trunking.
Depth to rear of module (copper): 11.43mm

CFPTS4EW

CFTSL4AW

CFTSL4EW

Polar White

1

10

European

White

1

10

• Design to be used with Elko faceplate frame

• Can be clearly identified with label and 

label cover

• Individual modules snap in and out

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Elko Faceplate

CES3AW

Sloped faceplate holds up to four 

M

INI

-C

OM

Modules. To be used with Elko faceplate frame.
Includes back plate, label/label cover and screws 
for mounting.

Arctic 
White

1

10

Elko Faceplate – Sweden, Norway, Denmark and Netherlands

CES3AW

Panduit-Pannet-html.html
background image

39

Module Inserts for Bezels

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

2 Module Space, 1/2 Size, Sloped Module Insert

CHS2AW-X

Sloped module insert accepts up to two 

M

INI

-C

OM

Modules and accommodates up to 1/2 of a single gang
bezel. Depth to rear of modules: 16.5mm

Arctic White

10

50

CHS2BL-X

Black

10

50

CHS2IW-X

Off White

10

50

CHS2PW-X

Polar White

10

50

CHS2WH-X

White

10

50

2 Module Space, 1/2 Size, Sloped Module Insert with Protective Shutters

CHS2SAW-X

Sloped module insert with protective shutters accepts up
to two 

M

INI

-C

OM

Modules and accommodates up to 1/2

of a single gang bezel. Shutters are spring loaded and
rotate out of the way for cable connections. Depth to rear
modules: 16.5mm

Arctic White

10

50

CHS2SBL-X

Black

10

50

CHS2SIW-X

Off White

10

50

CHS2SPW-X

Polar White

10

50

CHS2SWH-X

White

10

50

2 Module Space, 1/2 Size, Flat Module Insert

CHF2AW-X

Flat module insert accepts up to two 

M

INI

-C

OM

Modules

and accommodates up to 1/2 of a single gang bezel.
Depth to rear of modules: 25.4mm

Arctic White

10

50

CHF2BL-X

Black

10

50

CHF2IW-X

Off White

10

50

CHF2PW-X

Polar White

10

50

CHF2WH-X

White

10

50

2 Module Space, 1/2 Size, Sloped, Recessed Module Insert

CHSR2AW-X

Accepts up to two 

M

INI

-C

OM

Modules and accommodates

up to 1/2 of a single gang bezel. Depth to rear of 
modules: 28.6mm

Arctic White

10

50

CHSR2BL-X

Black

10

50

CHSR2IW-X

Off White

10

50

CHSR2PW-X

Polar White

10

50

CHSR2WH-X

White

10

50

2 Module Space, 1/3 Size Flat Module Insert

CHF2MAW-X

Flat insert accepts up to two 

M

INI

-C

OM

Modules and

accommodates 1/3 of a single gang bezel. Twelve ports
maximum in a double gang bezel. Depth to rear of
modules: 25.4mm

Arctic White

10

50

CHF2MBL-X

Black

10

50

CHF2MIW-X

Off White

10

50

CHF2MPW-X

Polar White 10

CHF2MWH-X

White

10

50

CHS2

CHS2S

CHF2

CHS2R

CHF2M

Wall Board Adapters

• Provide a mounting surface for single or double gang faceplates

MWBA1

MWBA-2G

Adapters supplied with mounting screws.

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

MWBA1

An alternative for single gang in-wall box in communication
applications. Mounting hole spacing of 83.5mm.

1

10

MWBA-2G

An alternative for double gang in-wall boxes in communication
applications. Mounting hole spacing of 83.5mm.

1

10

50

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

40

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

M

INI

-C

OM

In-Wall Fibre Spool

• 35mm internal bend radius

• Cable entry/exit from rear, top and bottom

helps maintain external bend radius

• Stores up to 12 meters of unjacketed fibre

cable or 2 meters of jacketed fibre cable

• 93mm depth from rear of faceplate, not for use

with in-wall boxes or in shallow walls

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Two Module In-Wall Fibre Spool

CFS2AW

Two piece fibre spool for use with most M

INI

-C

OM

faceplates, bezels and inserts.

Arctic White

1

10

CFS2BL

Black

1

10

CFS2IW

Off White

1

10

CFS2WH

White

1

10

M

INI

-C

OM

Snap-On Modular Furniture Faceplate

• Accept 

M

INI

-C

OM

Modules for Copper and

Fibre applications

• High density design; accepts up to 4 snap-in

M

INI

-C

OM

Modules

Faceplate snaps into 

"industry standard"

opening with panel cutout specified. Consult factory for specific 

furniture manufacturer’s opening sizes for solutions for other sizes.

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

4 Module Space Modular Furniture Snap-On Faceplate

CFFP4BL

Faceplate snaps into knockouts found on modular
furniture. Holds four standard connecto modules. 
Depth to rear of modules: 25mm

Black

1

10

2 Module Space Angled Modular Furniture Snap-On Faceplate

CFFPA2BL

Furniture snaps into knockouts found on modular
furniture. Holds two standard connector modules. 
Depth to rear modules: 15mm

Black

1

10

Standards: TIA/EIA-568-A
requires a minimum 1 metre

slack and a fibre spool for 
in-wall installations.

CFFP4BL

CFFPA2BL

CFFPL4

CFFPL4BL

Faceplate snaps into industry standard knockouts found
on modular furniture. Accepts up to four 

M

INI

-C

OM

Modules.  Supplied with write-on label and label cover.

Black

1

10

Snap-On Modular Furniture Faceplate Extender

MFFPEBL

For use when depth inside modular furniture base is
limited.  Extends plate approximately 1/2" (12.7mm).
Accepts CFFPL4 and CFFP4 modular faceplates.

Black

1

10

MFFPE

CFFPHM4

4 Module Space Herman Miller

n

Furniture Snap-On Faceplate

CFFPHM4BL

Faceplate snaps into knockouts found on Herman
Miller

n

furniture such as Action Office Series 2 and 3

and Ethospace Baseline. Accepts up to four
M

INI

-C

OM

Modules.

Black

1

10

4 Module Space Herman Miller

n

Ethospace Beltline Furniture Snap-On Faceplate

CFFPEBSL4BL

Sloped faceplate snaps into knockouts found on Herman
Miller

n

furniture such as Ethospace Beltline. Accepts up to

four 

M

INI

-C

OM

Modules. Supplied with write-on label

and label cover and icon slots.

Black

1

10

CFFPEBSL4

Panduit-Pannet-html.html
background image

41

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

M

INI

-C

OM

Shuttered Surface Mount Boxes

• Accept 

M

INI

-C

OM

Modules for STP and UTP, FJ

Fibre

Optic Jack Modules and other flush modules, which snap
in and out for easy moves, adds and changes

• Clear shuttered doors are spring-loaded to stay closed to

prevent dust from entering module opening; doors can be
collapsed to insert plug into module

• Cable entry from side, rear and base knockouts 
• Mount easily with supplied mounting screws, adhesive 

tape or optional magnet (CSBM-X)

• Optional icons available
• Optional adhesive labels available

‡ For other colours replace suffix IW (Off White) with EI (Electric Ivory), WH (White), IG (International Grey)
or BL (Black).
*Raceway does not enter box.

Part Number

Part Description

Colour

Used with
P

AN

-W

AY

Raceway

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CBXS1IW-A

Shuttered surface mount box accepts one
M

INI

-C

OM

Module.  .62"H x 1.64"W x

2.47"L (15.75mm x 41.66mm x 62.73mm).

Off

White

LD5/LDP5*

1

10

CBXS2IW-A

Shuttered surface mount box accepts two
M

INI

-C

OM

Modules. .94"H x 2.40"W x

2.5"L (23.88mm x 60.96mm x 63.50mm).

Off

White

LD5/LDP5*

1

10

CBXS3IW-A

Shuttered surface mount box accepts three
M

INI

-C

OM

Modules. .94"H x 3.62"W x

3.31"L (23.88mm x 92.00mm x 84.00mm).

Off

White

LD5/LDP5

1

10

CBXS4IW-A

Shuttered surface mount box accepts four
M

INI

-C

OM

Modules.  .94"H x 4.65"W x

3.28"L (23.88mm x 118.11mm x 83.31mm).

Off

White

LD3/LDP3
LD5/LDP5

1

10

CBXS6IW-A

Shuttered surface mount box accepts six
M

INI

-C

OM

Modules.  .94"H x 6.7"W x

3.28"L (23.88mm x 170.18mm x 83.31mm).

Off

White

LD3/LDP3
LD5/LDP5

1

10

CBXSD6IW-A

Deep shuttered surface mount box accepts
six 

M

INI

-C

OM

Modules (includes cable

routing bridge). 1.16"H x 7.58"W x 3.86"L
(29.60mm x 192.50mm x 98.00mm).

Off

White

LD5/LDP5

LD10/LDP10

1

10

CBXS1

CBXS2

CBXS3

CBXS4

CBXS6

CBXSD6

Panduit-Pannet-html.html
background image

LD3,

LDP3,

LDS3*

LD3, LDP3,

LD5*, LDP5

42

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

M

INI

-C

OM

Surface Mount Boxes

• Cable entry from side and rear knockouts and from

opening in base

• Accept 

M

INI

-C

OM

Modules including Category 5e,

Category 6, Fibre Optic and Coax cables found on page
20-21 and pages 25-29 

• Surface box screw covers found on page 43 can be used

in place of clear label holders on boxes with label/label
cover feature 

• Mount easily with supplied mounting screws, adhesive 

tape or optional magnet (CSBM-X)

• Combination label holder/screw cover for custom

identification (4 module space and greater not 
including CBXC4)

• Can be clearly identified with labels found on 

pages 349 - 356

CBX1

CBXJ2

CBX2

CBXC4

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

1 Module Space Surface Mount Box

CFS2AW

Surface mount box holds one

M

INI

-C

OM

Module. Supplied with adhesive backing.
22.8mm H x 25.5mm W x 47.7mm L

Arctic White

1

10

2 Module Space Surface Mount Box

CBXJ2AW-A

Surface mount box holds up to two
M

INI

-C

OM

Modules. Supplied with adhesive

backing. 23.1mm H x 45mm W x 62mm L

Arctic White

1

10

Can be

used with

P

ANWAY

Trunking

LD3, LDP3,

LD5, LDP5

2 Module Space Surface Mount Box

CBX2AW-A

Surface mount box holds up to two
M

INI

-C

OM

Modules. Supplied with adhesive

backing. 27mm H x 50mm W x 93mm L

Arctic White

1

10

LD3, LDP3,

LD5, LDP5

4 Module Space Low Profile Surface Mount Box

CBXC4AW-A

Surface mount box holds up to four
M

INI

-C

OM

Modules. Supplied with mounting

screws with adhesive backing. 23mm H x
80mm W x 80mm L

Arctic White

1

10

LD3, LD5, 

4 Module Space Surface Mount Box

CBXC4AW-A

Surface mount box holds up to four
M

INI

-C

OM

Modules. Provides slots that

accept cable ties for strain relief. Provides
bend radius control. Supplied with mounting
screws with adhesive backing. 22.8mm H x
74mm W x 114mm L

Arctic White

1

10

‡ Other colours available. See page 42.
*Trunking does not enter box.

CBX4

Standard Colour:

PW

Polar White

Black

BL

SG

Silk Grey

Colour shown

Colours shown are approximate 

is approximate. 

Other colours available:

WH

White

IW

Int. White

AW

Arctic White

Panduit-Pannet-html.html
background image

43

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

LD3, LD5,

LD10

LD3, LD10

M

INI

-C

OM

Surface Mount Boxes (Continued)

CBXD6

CBXJ2

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

6 Module Space Surface Mount Box

CBXD6AW-A

Surface mount box holds up to six
M

INI

-C

OM

Modules. Provides slots 

that accept cable ties for strain relief.
Provides bend radius control. Supplied
with mounting screws, adhesive backing
and label holder/screw cover. 26.3mm H
x 125.7mm W x 96.2mm L

Arctic White

1

10

12 Module Space Surface Mount Box

CBX12AW-A

Surface mount box holds up to twelve
M

INI

-C

OM

Modules. Supplied with mounting

screws, adhesive backing and label
holder/screw cover. 26mm H x 145mm 
W x 138mm L

Arctic White

1

10

Can be

used with

P

ANWAY

Trunking

‡ Other colours available. See page 42.
*Trunking does not enter box.

M

INI

-C

OM

Multi-Media/Fibre Surface Mount Boxes

• Accepts 

M

INI

-C

OM

Modules including Category 5e,

Category 6, Fibre Optic cables and Coax cables found on
pages 20-21 and 25-29

• Slots accept cable ties for cable management
• Mounts easily with screws or adhesive tape
• Tamper resistant screw for added security
• Unique fibre spool design secures cable in place
• Splicing capacity available
• Built-in fibre spool stores up to 24 meters of buffered fibre

optic cable

• Cable entry from side and rear knockouts and from

opening in bottom of base

• Surface box screw covers can be used in place of clear

label holders

• Fibre Box Expander upgrades CBXF6 to accept twelve

connector modules

• Can be clearly identified with labels found on 

pages 349-356

LD3, LD5, 

LD3, LD5,

LD10

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

6 Module Multi-Media/Fibre Boxes

CBXF6AW-A

Surface mount box holds up to sixe
M

INI

-C

OM

Modules. 25mm H x 

120mm W x 170mm L

Arctic White

1

10

12 Module Space Multi-Media/Fibre Boxes

CBXF12AW-A

Surface mount box holds up to twelve
M

INI

-C

OM

Modules. 46mm H x 120mm 

W x 170mm L

Arctic White

1

10

Can be

used with

P

ANWAY

Trunking

‡ Other colours available. See page 42.
*Trunking does not enter box.

CBXF6

CBXF12

CBXF6KIT

LD3, LD5,

LD10

Fibre Box Expander

CBXF6KITAW

Includes bridge, deep cover and tamper
resistant screw. Used to convert CBXF6 
into CBXF12

Arctic White

1

10

Panduit-Pannet-html.html
background image

44

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

NOTES

Panduit-Pannet-html.html
background image

45

P

AN

Z

ONE

Z

ONE

C

ABLING

S

OLUTIONS

PANDUIT

provides a complete line of Zone Cabling products for workspace environments,

including open office architecture and industrial applications. Each zone cabling product serves as

a high capacity main cable distribution point for a particular zone, feeding workstation outlets

with short cable runs for voice, data and video connections.

Active and Passive Zone Cabling provides the potential to reduce long term maintenance costs by

facilitating easy moves, adds and changes. Active Zone Cabling, where network electronics are

deployed in a zone, can solve communications room congestion problems and provide the

optimum hardware solution by extending the backbone.

PANDUIT

Zone Cabling products

accommodate multi-media solutions and can be used in floor,ceiling and wall mount applications.

Provide flexibility to reconfigure offices to meet
frequently changing organisational requirements

Provide the ability to make moves, adds and changes
quickly and easily

Reduce network downtime when changes
are required

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

46

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

1

2

3

Consolidation Point

Enclosures

(page 48)

P

AN

Z

ONE

Cable Assemblies

(page 51)

P

AN

Z

ONE

In-Ceiling

Zone Cabling Boxes

(page 49-50)

Zone Cabling Roadmap

6

6

3

1

2

Horizontal Cable

To
Telecommunications Room

Panduit-Pannet-html.html
background image

47

P

AN

Z

ONE

Enclosure & Doors

(page 50)

P

AN

Z

ONE

In-floor

Zone Cabling Boxes

(page 49)

4

5

4

5

3

To
Telecommunications
Room

M

INI

-C

OM

Faceplates (pages 32-

37) & Surface Mount Boxes

(pages 42-43)

5

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

48

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Punchdown Consolidation Point Enclosure

• Includes 

T

AK

-T

Y

Hook & Loop Cable Ties, grommets and

a choice of punchdown bases

• UL2043 approved for use in air-handling spaces

• Follows TIA/EIA-568-B standard
• Mounts to wall above and below ceiling

WMCPESGBL

Consolidation Point Boxes and Fibre Conversion Kit

• UL2043 approved for use in air-handling spaces
• Supports 

M

INI

-C

OM

Modules

• Supplied with cable management accessories

• Suitable for wall mount and under floor applications
• Optional fibre conversion kit available for use in both boxes

CUFMB24BL

CUFB48BL

CUFF-KIT

Part Number

Part Description

Std.

Pkg.

Qty.

WMCPESGBL

Fully assembled aluminium enclosure, which includes 24 port/4-pair
standard density 

G

IGA

-P

UNCH

Category 6 base and 

T

AK

-T

Y

Hook &

Loop Cable Ties. Dimensions: 86.36mmH x 240.54mm W x 335.79mm L

1

WMCPEPPBL

Fully assembled aluminum enclosure, which includes 110 pair 
P

AN

-P

UNCH

base and 

T

AK

-T

Y

Hook & Loop Cable Ties. Dimensions:

87.38mm H x 240.54mm W x 335.79mm L

1

WMCPEBL

Aluminium enclosure with 

T

AK

-T

Y

Hook & Loop Cable Ties. Dimensions:

87.38mm H x 240.54mm W x 335.79mm L

1

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CUFMB24BL

24 Port Aluminium Under Floor Consolidation Point Box includes
pre-printed numbered labels with writable surface on back when
pre-numbered labels are not applicable. Dimensions: 
42.92mm H x 275.59mm W x 271.02mm L

1

CUFB48BL

48 Port Under Floor Consolidation Point Box made of 16 gauge
rugged steel for long term durability. Dimensions: 
41.40mm H x 254.0mm W x 377.95mm L

1

CUFF-KIT

Optional fibre conversion kit to be used with CUFB48BL and
CUFMB24BL.  Kit includes: 4 

PANDUIT

P

AN

-T

Y

Cable Ties, 4

wire saddles, 2 adhesive fibre spools, 2 support brackets to hold
fibre cable, 1 grounding lug, 1 laser warning label,1 fibre warning
label and 2 rubber grommets.

1

10

Panduit-Pannet-html.html
background image

49

P

AN

Z

ONE

In-floor Zone Cabling Boxes

• Accepts all flat 

M

INI

-C

OM

Patch Panels

• UL2043 approved for use in air-handling spaces
• Work with standard 610mm x 610mm raised floor panels

• Meets NEC standards
• Plenum rated foam kit and mounting bracket included

^ One rack space = 44.45mm

CIFZC11

CICZC2X2

CICZCBRKT

P

AN

Z

ONE

In-ceiling Zone Cabling Box

• UL2043 approved for use in air-handling spaces
• Meets NEC standards
• Plenum rated foam kit included

• Optional bracket (CICZCBRKT) allows zone cabling box to

accept all 

M

INI

-C

OM

patch panels

^ One rack space = 44.45mm

P

AN

Z

ONE

Active In-ceiling Zone Cabling Box

• Designed to accept up to 3 RU of active electronics as

deep as 393.7mm and up to 6 RU of 482.6mm standard
passive connectivity

• AC power ready (receptacle not included)
• UL2043 approved for use in air-handling spaces

• Meets NEC standards
• 11kg door weight capacity
• Includes doorplate, equipment mounting bracket, plenum

rated foam kit and 9 CFM fan (fan provides in excess of
100 air changes per hour)

^ One rack space = 44.45mm

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

CIFZC4

Fully assembled In-floor Zone Cabling Box which requires 152.4mm
minimum access floor.  Accepts up to 4 RU of 19" standard patch
panels.  Dimensions: 609.60mm L x 609.60mm W x 101.60mm D

4

1

CIFZC8

Fully assembled In-floor Zone Cabling Box which requires 203.2mm
minimum access floor.  Accepts up to 8 RU of 19" standard patch
panels.  Dimensions: 609.60mm L x 609.60mm W x 152.40mm D

8

1

CIFZC11

Fully assembled In-floor Zone Cabling Box which requires 355.6mm
minimum access floor.  Accepts up to 11 RU of 19" standard patch
panels.  Dimensions: 609.60mm L x 609.60mm W x 304.80mm D

11

1

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CICZC2X2

Fully assembled In-ceiling Zone Cabling Box.  Accepts up
to six 100 pair punchdown bases.  With optional brackets
(CICZCBRKT) this box also accepts up to 9 RU of
482.6mm standard patch panels.  Mounts in 2x2, 2x4,
and 2x6 ceiling panels.  Dimensions: 609.60mm L x
609.60mm W x 304.80mm D

1

CICZCBRKT

In-ceiling zone cabling bracket designed to accept up 
to 9 RU of 482.6mm standard patch panels and mounts
inside an in-ceiling zone cabling box (CICZC2X2), 
sold separately.

9

1

10

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

CICZC2X2A

Fully assembled In-ceiling Zone Cabling Box. Mounts in 2x2, 2x4
and 2x6 ceiling panels.  Dimensions: 596.90mm L x 596.90mm W 
x 308.10mm D

9

1

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

50

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

Z

ONE

Enclosures

• Can be directly mounted to a wall, recessed into a wall or

used in under floor applications

• Include grommet edging, labels and 

T

AK

-T

Y

Hook & Loop

Cable Ties

• Option of flat cover or hinged lockable door 

(each sold separately)

• Accommodate up to four 100 pair punchdown bases or

optional patch panel bracket (PZBPPB) can be used 
to accommodate up to 2 RU of standard 482.60mm 
patch panels

• Conduit knockouts of 44.45mm - 50.8mm are available on

top and bottom, Side conduit knockouts of 38mm are
available on the sides

PZB4 with PZB4-HC

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

P

AN

Z

ONE

Enclosure

PZB4

Enclosure can be mounted directly to wall, recessed into a wall or used
in under floor applications.  Hinged door or flat cover sold separately.
Dimensions: 635.00mm H x 368.30mm W x 118.11mm D

1

PZB4-HC

Hinged door to be used with 

P

AN

Z

ONE

Enclosure (PZB4) when

mounting to a wall or under floor.  Reversible door can hinge from
either side and includes lock with tab release.

1

PZB4-FC

Flat cover to be used with 

P

AN

Z

ONE

Enclosure (PZB4) when

mounting to wall or under floor.  Cover includes four screw slots 
and screws.

1

Optional

P

AN

Z

ONE

Bracket

PZBPPB

P

AN

Z

ONE

Patch Panel Bracket accommodates up to 2RU of standard

482.6mm patch panels.  Includes one pair of brackets.

1

10

P

AN

Z

ONE

Active Wall Mount Enclosure

• Includes lockable door for tamper resistance; optional

cooling fan and lock set are available

• Door can be assembled to hinge on either the right or left

side, which allows easy access when the enclosure is
mounted in a corner

• Accommodates 3RU of 482.6mm standard patch panels

and 3RU of active equipment (Maximum allowable depth 
of active equipment is 444.5mm)

• Designed to accommodate Cisco, APC hardware and

select cooling fans

• For fibre backbone applications, use 

M

INI

-C

OM

TM

Surface

Mount Box (CBXF6) for fibre demarcation

• Includes low penetration air vents on both sides to keep

falling water and debris out of the enclosure while allowing
air to circulate

• Raceway knockouts on all sides accommodate 

PANDUIT

T-70 and larger Raceways

• Includes grommet edging for raceway knockouts and 

T

AK

-T

Y

Hook & Loop cable ties for cable management

• Conduit can be used for cables entering and exiting the

box; ten knockouts for cable access (44.45mm or 50.8mm
conduit), and six knockouts for power applications (12.7mm
or 19.05mm conduit)

• Conduit knockouts also allow power to be run to a standard 

electrical box inside the enclosure, which is required for
active equipment applications

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

PZAEWM3

P

AN

Z

ONE

Active Wall Mount Enclosure can be mounted directly to a

wall. Dimensions: (977.9mm x 709.2mm x 218.7mm).

1

0

PZAEFAN

Optional cooling fan for applications where additional cooling
is required.

1

0

PZAELOCK

Optional keyed lock set; includes 2 locks and 2 keys for each lock

1

10

Panduit-Pannet-html.html
background image

51

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

Z

ONE

Cable Assemblies

P

AN

Z

ONE

cable Category 6 Solid UTP and SFTP

Assemblies for use in Zone Cabling applications

• Available in plug to jack module and plug to 

plug configurations

• Available in PVC and LSZH jacket material
• T568B wiring

UJPBU

UPBU

Part Number

Part Description

Length

Cable

Colour

Std.

Pkg.

Qty.

M

Plug to Plug UTP Cable Assemblies

PVC

UPBU5M

PVC Category 6 UTP Solid Cable with TX6
Plus Modular plugs on each end.

5

Blue

1

UPBU7M

7

Blue

1

UPBU8M

8

Blue

1

C

ABLE

A

CCESS

Wall Mount Cabinet

• Innovative cable routing allows easy cable installation in to

the cabinet without threading cables through an opening.

• Multiple Access Points provide easy access to inside of

cabinet during cable installation and maintenance

• Slack manager allows the standardisation of a single patch

cord length while keeping the cabinet organised and
manageable.

• Robust design and locking access doors provide 

security protection

• Vented design and optional fan provides climate control for

various switches and power supplies 

• Adjustable rails mount at 25.4mm increments with rack

space identification for easy location of rack spaces

• Meets GR-1089 Grounding and Bonding specification when

used with grounding kit

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

NC24S

C

ABLE ACCESS

with solid door

NC24W

C

ABLE ACCESS

with window door

NCFK

C

ABLE ACCESS

fan kit

NCGK

C

ABLE ACCESS

grounding kit

NCSD

C

ABLE ACCESS

solid duct

NCSM12

12 RU slack manager

UPBU10M

10

Blue

1

UPBU30M

30

Blue

1

UPBU40M

40

Blue

1

P

AN

Z

ONE

Wireless Access Point Enclosure

• Lockable enclosure protects against tampering and theft

and reduces TCO

• WAP mounting in base of enclosure eliminates movement

of active equipment when door is opened for improved
network reliability

• Attached door with knockouts allows multiple antenna

configurations to support IEEE 802.11a, b and g standards
and reduces installation time 

• Included connectivity accessory kit provides 2-position

surface mount box, 5e jack, 5e patch cord and grounding
cable to simplify installation and reduce inventory 

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

PZWIFIE

Wall Mountable Wireless Access Point Enclosure

1

PZWIFICB

Converts PZWIFIE to Ceiling Mountable Enclosure

1

Panduit-Pannet-html.html
background image

F6JBP5ZIB3MBL

F6JBP5ZIB5MBL

F6JBP5ZIB7MBL

F6JBP5ZIB8MBL

F6JBP5ZIB10MBL

F6JBP5ZIB20MBL

F6JBP5ZIB30MBL

52

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Part Number

Part Description

Length

Cable

Colour

Std.

Pkg.

Qty.

M

Plug to Jack UTP Cable Assemblies

PVC

UJBU3MBL

PVC Category 6 UTP Solid Cable with 

TX6

PLUS Modular Plug on one end and a black
PANDUIT

M

INI

-C

OM

TX6

PLUS Jack on

the other end

3

Blue

1

UJBU5MBL

5

Blue

1

UJBU7MBL

7

Blue

1

UJBU10MBL

10

Blue

1

UJBU15MBL

15

Blue

1

UJBU20MBL

20

Blue

1

UJLBU3MBL

LSZH Category 6 UTP Solid Cable with
TX6

PLUS Modular plug on one end and a

black 

M

INI

-C

OM

TX6

PLUS Jack on the

other end

3

Blue

1

UJLBU5MBL

5

Blue

1

UJLBU7MBL

7

Blue

1

UJLBU10MBL

10

Blue

1

UJLBU15MBL

15

Blue

1

UJLBU20MBL

20

Blue

1

Plug to Jack UTP Cable Assemblies

LSZH

P

AN

Z

ONE

Cable Assemblies

STPCTG3MBBL

LSZH Category 6 SFTP Stranded Cable with
TX6

PLUS Modular plugs with black boots

on each end

3

Grey

1

STPCTG5MBBL

5

Grey

1

STPCTG7MBBL

7

Grey

1

STPCTG8MBBL

8

Grey

1

STPCTG10MBBL

10

Grey

1

STPCTG30MBBL

30

Grey

1

Plug to Plug SFTP Stranded Cable Assemblies

LSZH

STPCTG40MBBL

40

Grey

1

LSZH Category 6 SFTP Stranded Cable
26AWG with 

TX6

PLUS Modular plugs on

one end a black 

M

INI

-C

OM

TX6

PLUS

Jack on the other end

3

Grey

1

5

Grey

1

7

Grey

1

8

Grey

1

10

Grey

1

20

Grey

1

Plug to Jack SFTP Stranded Cable Assemblies

LSZH

30

Grey

1

UPBU20

Non-Plenum Category 6 UTP Solid Cable
with 

TX6

PLUS Modular Plug on each end.

6.1

Blue

1

UPBU50

15.2

Blue

1

UPBU40M

40

Blue

1

UPBU100

30.5

Blue

1

PVC

Plug to Plug UTP Cable Assemblies

UPLBU5M

LSZH Category 6 UTP Solid Cable with TX6
Plus Modular plugs on each end

5

Blue

1

UPLBU7M

7

Blue

1

UPLBU8M

8

Blue

1

UPLBU10M

10

Blue

1

UPLBU30M

30

Blue

1

UPLBU40M

40

Blue

1

LSZH

Part Number

Part Description

Length

Cable

Colour

Std.

Pkg.

Qty.

M

Part Number

Part Description

Length

Cable

Colour

Std.

Pkg.

Qty.

M

Panduit-Pannet-html.html
background image

53

The PANDUIT

Network Connectivity Group offers solutions for all twisted pair copper cabling 

applications. Systems are designed to exceed the latest industry standards, providing assurance of

network reliability. The 

PANDUIT

solution will support emerging technologies, including Voice

over IP and Gigabit Ethernet.

The 

TX6

PLUS

Copper Connectivity System includes the 

M

INI

-C

OM

TX6

PLUS

Modules,

DP6

PLUS

Patch Panels,

TX6

PLUS

Category 6 Patch Cords,

GP6

PLUS

Punchdown System and 

TX6

PLUS

Modular Plugs.

PANDUIT

also offers solutions for reliable Category 5e performance with the

M

INI

-C

OM

TX5e

Jack Modules,

DP5e

Patch Panels, Category 5e Patch Cords,

P

AN

-P

UNCH

Punchdown System and 

P

AN

-P

LUG

Modular Plugs.

PANDUIT

solutions are designed with the

flexibility to support your growing and changing network requirements.

Modular system eases installation and moves,
adds and changes

High density conserves valuable rack space

Backwards compatibility supports 
existing infrastructure

Products support worldwide applications

Continual investment in research & development

P

ATCH

P

ANELS

, C

OPPER

P

ATCH

C

ORDS

,

P

UNCHDOWN AND CABLE

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

54

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

1

3

4

2

Punchdown

Patch Panels

(page 63)

Punchdown Rack Mount

Panels

(page 78)

M

INI

-C

OM

Jack Modules 

(pages 20 - 21)

M

INI

-C

OM

Modular Patch

Panels

(page 62)

Copper Connectivity System

5

5

5

Horizontal Cabling

Horizontal Cabling

Patch
Cords

Equipment
Cords

Patch Panels

Patch Panels

To

Work

Area

Interconnection
Configuration

Cross-Connection
Configuration

Telecommunications
Room

To Active Equipment Rack

To Active Equipment Rack

2

3

4

1

2

3

4

1

Complete Solutions for both Category 5e and Category 6

Panduit-Pannet-html.html
background image

55

5

1

5

1

Consolidation
Point

To
Telecommunications
Room

Basic
Configuration

Consolidation
Point
Configuration

Work Area

Horizontal Cabling

Horizontal Cabling

5

Patch Cords

(pages 68 - 70)

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

56

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

DPoE

Power Patch Panel and Power System

• Power Patch Panesl are fully compliant with IEEE 802.3af

and Cisco Inline Power specifications   

• RJ45 terminations with LEDs on front of panel to indicate

port powering or port status 

• 110 punchdown terminations on rear of panel achieve

highest density solution compared to traditional midspan
hubs and terminate to outlets to supply data and power 

• 2 RJ45 terminations on rear of panel offer network

management connections

• Terminates 4 pair 22-24 AWG 100 ohm solid and stranded

unshielded twisted pair cable

• DPOEPWRB120 Power Supply design minimises space

consumption and allows for flexible placement inside rack 

• Power Systems low profile design offers a combination of

high-power and small size for the enterprise data centre,
embedded applications or telecommunications needs 

• 48 Volt Power via 3 hot swappable rectifiers (ordered

separately – must use DPoEPWRR500 or DPoEPWR1250
in any combination) supply a minimum of 500 watts to a
maximum of 3,750 watts depending upon configuration 

• 14 fuse slots allow for 14 individual DPoE24U1X Power

Patch Panels to be connected to a single chassis

^ One rack space = 44.45mm
Power Supply and Power System requires proper A.C. country specific power cord (Cord-A for Australia, Cord-E
for Europe, Cord-S for United States or Cord-U for United Kingdom) must be ordered separately.

DPOE24UIX

DPOEPWRB120

DPOEPWRCU

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Power Patch Panel

DPOE24U1X

24 port Power Over Ethernet (PoE) power patch panel
supports 10/100 ethernet connectivity.

1

1

Power Supply

DPOEPWRB120

DPoE

120 Watt Power Supply. Suitable for single power

patch panel installations with low power needs or a mixture
of active and passive devices.

1

Power Systems

DPOEPWRCU

DPoE

Power System Unmanaged Chassis: Utilised for

supplying power to single and multiple power patch panels
when equipped with the appropriate 

DPoE

Power Rectifiers.

1

1

DPOEPWRCM

DPoE

Power System Managed Chassis: Utilised for

supplying power to single and multiple power patch panels
when equipped with the appropriate 

DPoE

Power

Rectifiers. This chassis is meant to be used with a separate
battery backup storage system to form the heart of a
universal power distribution system.

1

1

DPOEPWRR500

DPoE

500 Watt Power Rectifier supplies power for multiple

power patch panels. A combination of 3 of these rectifiers will
support 4 to 7 panels. Used with DPOEPWRC*.

1

DPOEPWRR1250

DPoE

1250 Watt Power Rectifier supplies power for

multiple power patch panels. A combination of 3 of these
rectifiers will support up to 14 panels. Used
with DPOEPWRC*.

1

DPOEPWRNIC

DPoE

Network Interface Card. Upgrade to the 

DPoE

Power System Unmanaged Chassis, allowing control of
additional power system parameters.

1

Panduit-Pannet-html.html
background image

57

For technical assistance please call 

PANDUIT

Component Labels for 

DPoE

Power Patch Panel and Power System

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Panel

Part Number

Laser/Ink Jet Desktop Printer Label

P

ANTHER

LS8 Handheld 

Thermal Printer

All Patch
Panels on 
this Page

C379X030FJJ

C379X030FJC

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

M

INI

-C

OM

Modular Faceplate Patch Panels

• Allow front access to installed modules for easy moves,

adds and changes

• Accept 

M

INI

-C

OM

Modules for UTP (including Category

5e and Category 6), Fibre Optic and Coax, which snap in
and out for easy moves, adds and changes

• Label versions available for easy port identification,

replacement label / label covers available

• Mount to standard TIA/EIA 19” or  23” 

racks with optional extender bracket

CPPL24WBL

CPPL48WBL

CPP24WBL

CPP48WBL

C4PPLK

^ One rack space is 44.45mm
M6 and #12-24 mounting screws included.
* The TIA/EIA-606-A Standard states that all labels shall be mechanically generated, write on labels are not 
standard compliant.

Part Number

Part Description

No. of 

Rack 

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

M

INI

-C

OM

Modular Patch Panels with Labels

CPPL24WBL

24 port patch panel with labels, supplied with 6
CFFPL4 type snap-in faceplates.

1

1

10

CPPL48WBL

48 port patch panel with labels, supplied with 12
CFFPL4 type snap-in faceplates.

2

1

10

M

INI

-C

OM

Modular Patch Panels

CPP24WBL

24 port patch panel supplied with 6 CFFP4 type 
snap-in faceplates.

1

1

10

CPP48WBL

48 port patch panel supplied with 12 CFFP4 type
snap-in faceplates.

2

1

10

Replacement Labels for 

M

INI

-C

OM

Modular Patch Panels

C4PPLK*

Replacement label / label cover kit for 

M

INI

-C

OM

Modular Patch Panels with Label / Label Covers
(CPPL24WRBL, CPPL48WRBL, CPPL24WBL,
CPPL48WBL) and 

M

INI

-C

OM

Modular Furniture

Faceplates (CFFPL4, CFPHSL4, CFFPEBSL4). Each
kit contains 6 labels and 6 clear label covers per bag.

1

10

CGJT

CJT-X

CJAST

CWST

AVPDB

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CGJT

Terminates 

G

IGA

-TX

Style Jack Modules

1

50

CJT-X

Terminates 

MI

NI

-C

OM

M

INI

-J

ACK

Jack Modules

10

50

CWST

Copper wire snipping tool, cuts conductors flush for improved
performance.

1

CJAST

Adjustable, single handed stripping tool, strips outer jacket of 4-pair
UTP and ScTP cable.

1

AVPDB

Audio Video Punchdown Base used to assist in terminating 

MI

NI

-C

OM

S-Video and RCA punchdown modules

1

50

Module Termination Tools

Panduit-Pannet-html.html
background image

58

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Component Labels for 

M

INI

-C

OM

Modular Faceplate Patch Panels

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com
‡For non-adhesive labelling solution, do not remove liner from label.

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Panel

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

CPPL24WBL
CPPL48WBL

C261X035Y1J

C261X035Y1C

CPP24WBL
CPP48WBL

C125X030FJJ

C125X030FJC

Component Labels for 

M

INI

-C

OM

M6 Style Modular Faceplate Patch Panels

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com
‡For non-adhesive labelling solution, do not remove liner from label.

M

INI

-C

OM

M6 Style Modular Faceplate Patch Panels

• Allow front access to installed modules for easy moves,

adds and changes

• Accept 

M

INI

-C

OM

Modules for UTP (including Category

5e and Category 6), Fibre Optic and Coax, which snap in
and out for easy moves, adds and changes

• Include pre-printed numbered labels with writable surface

on back when pre-numbered labels are not applicable

• Mount to standard TIA/EIA 19” or 23” racks with optional

extender bracket

CPPL24M6BL

CPPL48M6BL

C6PPLK1-24

C6PPLK25-48

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included.
* The TIA/EIA-606-A Standard states that all labels shall be mechanically generated, write-on labels are not 
standard compliant.

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Panel

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

CPPL24M6BL
CPPL48M6BL

C261X035Y1J

C261X035Y1C

Part Number

Part Description

No. of 

Rack 

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

M

INI

-C

OM

Modular 6 Port Faceplate Patch Panel

CPPL24M6BL

24 port patch panel, supplied with 4 CFPLM6BL
snap-in faceplates.

1

1

10

CPPL48M6BL

48 port patch panel, supplied with 8 CFPLM6BL
snap-in faceplates.

2

1

10

Replacement Labels for 

M

INI

-C

OM

Modular Patch Panels

C6PPLK1-24*

Replacement labels for 

M

INI

-C

OM

Modular 6 port

Faceplate Patch Panels with Label / Label Covers
(CPPL24M6BL). Labels are pre-printed 1-24 on one
side and write on area on reverse side.

1

10

C6PPLK25-48*

Replacement labels for 

M

INI

-C

OM

Modular 6 port

Faceplate Patch Panels with Label / Label Covers
(CPPL**M6BL). Labels are pre-printed 25-48 on one
side and write on area on reverse side.

1

10

Panduit-Pannet-html.html
background image

Suggested Label Solutions for TIA/EIA-6060A Compliance

Patch Panel

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

CPPL72WBL

C282X030Y1J

C282X030Y1C

• Accept 

M

INI

-C

OM

Modules for UTP (including Category

5e and Category 6), Fibre Optic and Coax, which snap in
and out for easy moves, adds and changes

• Mount to standard TIA/EIA 19” rack or 23” racks with

optional extender bracket

CPP48HDWBL

CPPL72WBL

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included.

For complete labelling solutions and product information, reference the Labelling and Administration section on
page 349-356 and www.panduit.com
‡For non-adhesive labelling solution do not remove liner from label.

Component Labels for 

M

INI

-C

OM

High Density Modular Faceplate Patch Panels

Part Number

Part Description

No. of 

Rack 

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CPP48HDWBL

48 port patch panel supplied with 6 eight snap-in
faceplates. Ports are pre-printed 1 - 48 on 
patch panel

1

1

10

CPPL72WBL

72 port patch panel with labels, supplied with 6
twelve port front removable snap-in faceplates. 
Pre-printed numbered labels include a writable
surface on back when pre-numbered labels are 
not applicable.

2

1

10

M

INI

-C

OM

Flush Mount Modular Patch Panels

• Flush mount design provides a solution for non-shielded 

installations that do not require all metal patch panels

• Rear mounted faceplates allow modules to be flush with front of

patch panel

• Accept 

M

INI

-C

OM

Modules for UTP (including Category 5e and

Category 6), Fibre Optic and Coax, which snap in and out for easy
moves, adds and changes

• Pre-printed numbers above each port for easy identification

• White write-on areas for port and/or panel identification

• Mount to standard TIA/EIA 19” rack or 23” racks with optional

extender bracket

• Angled patch panels eliminate the need for horizontal 

cable managers

• Compatible with 

PANDUIT

P

ATCH

R

UNNER

Cable 

Management System

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included.

Part Number

Part Description

No. of Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CPPA24FMWBL

Angled 24 port flush mount patch panel, supplied
with 6 four port rear mounted faceplates.

1

1

10

CPPA48FMWBL

Angled 48 port flush mount patch panel, supplied
with 6 eight port rear mounted faceplates.

2

1

10

CPPA24FMWBL

CPPA48FMWBL

59

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

M

INI

-C

OM

High Density Modular Faceplate Patch Panels

Panduit-Pannet-html.html
background image

60

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

M

INI

-C

OM

Angled Modular Faceplate Patch Panels

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com
‡For non-adhesive labelling solution do not remove liner from label.

Component Labels for 

M

INI

-C

OM

Angled Modular Faceplate Patch Panels

• Angled design allows cable to flow to each side of the rack

and eliminates the need for horizontal cable managers by
enabling patch cords to be routed directly into vertical
cable managers

• Allow labelling scheme and port identification to be visible

at all times

• Allow front access to installed modules for easy moves,

adds and changes

• Accept 

M

INI

-C

OM

Modules for UTP (including Category 5e

and Category 6), Fibre Optic and Coax, which snap in and
out for easy moves, adds and changes

• Mount to standard TIA/EIA 19” rack or 23” racks with

optional extender bracket

• Compatible with 

P

ATCH

R

UNNER

Network Cable

Management System

CPPLA24WBL

CPPLA48WBL

CPPLA72WBL

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included.

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Panel

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

CPPLA24WBL
CPPLA48WBL

C261X035Y1J

C261X035Y1C

CPPLA72WBL

C282X030Y1J

C282X030Y1C

M

INI

-C

OM

Angled High Density Modular Patch Panel

• Quadruple Patch Panel Density
• Angled Patch Panel eliminates need for horizontal 

cable manager

• High Density Patch Panel provide 48 port in one 

rack space

• Result is 48 ports in one rack space vs. 24 ports in two

rack spaces 

• Allows port identification to be visible at all times
• Accept 

M

INI

-C

OM

Modules for UTP (including Category 5e

and Category 6), Fibre Optic and Coax, which snap in and
out for easy moves, adds and changes

• Mount to standard TIA/EIA 19” rack or 23” racks with

optional extender bracket

• Vertical cable managers in the 

PANDUIT

P

ATCH

R

UNNER

Cable Management System utilise moulded cable 
management fingers and integral bend radius control
These features coupled with Angled Patch Panels provide
the ultimate high density cable management system

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included.

Part Number

Part Description

No. of Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CPPA48HDWBL 48 port angled patch panel supplied with 6 eight

port snap-in faceplates. Ports are pre-printed 1 - 48
on patch panel.

1

1

10

Part Number

Part Description

No. of 

Rack 

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CPPLA24WBL

24 port angled patch panel with labels, supplied with
6 CFFPL4 type front removable snap-in faceplates.

1

1

10

CPPLA48WBL

48 port angled patch panel with labels, supplied with
12 CFFPL4 type front removable snap-in faceplates.

2

1

10

CPPLA72WBL

72 port angled patch panel with labels, supplied with
6 twelve port front removable snap-in faceplates. 
Pre-printed numbered labels include a writable
surface on back when pre-numbered labels are 
not applicable.

2

1

10

Panduit-Pannet-html.html
background image

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com
‡For non-adhesive labelling solution do not remove liner from label.

Component Labels for 

M

INI

-C

OM

Recessed Modular Faceplate

Patch Panels

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

Component Labels for 

M

INI

-C

OM

12 Port Modular Faceplate Patch Panels

• 75mm recessed feature eliminates patch cord interference

with cabinet doors and improves bend radius protection

• Release snap feature on faceplate allows front access to

installed modules for easy adds, moves and changes

• Accept 

M

INI

-C

OM

Modules for UTP (including Category

5e and Category 6), Fibre Optic and Coax, which snap in
and out for easy moves, adds and changes

• Label patch panels available for easy port identification,

replacement label / label covers available

• Mount to standard TIA/EIA 19” or 23” racks with optional

extender bracket

CPPL24WRBL

CPPL48WRBL

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included.

M

INI

-C

OM

12 Port Modular Faceplate Patch Panels

• Accept 

M

INI

-C

OM

Modules for UTP (including Category

5e and Category 6), Fibre Optic and Coax, which snap in
and out for easy moves adds, and changes

• Mount directly onto wall
• Modular design for easy cabling revisions

CWPP12WBL

CPP12WBL

WB89D

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Panel

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

CPPL24WRBL
CPPL48WRBL

C261X035Y1J

C261X035Y1C

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Panel

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

CWPP12WBL
CPP12WBL

C125X030FJJ

C125X030FJC

Part Number

Part Description

No. of Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CPPL24WRBL

24 port recessed patch panel with labels, supplied
with 6 CFFPL4 type front removable snap-in
faceplates. Designed for use with racks and cabinets.

1

1

10

CPPL48WRBL

48 port recessed patch panel with labels, supplied
with 12 CFFPL4 type front removable snap-in
faceplates. Designed for use with racks and cabinets.

2

1

10

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CWPP12WBL

12 port patch panel supplied with 3 CFFP4 snap-in faceplates.

1

10

CPP12WBL

12 port patch panel supplied with 3 CFFP4 snap-in faceplates.
Mounts to standard 89D bracket (WB89D).

1

10

WB89D

Wall mount bracket accepts 12 port snap-in faceplate patch panel.
Can also be used to mount industry standard 66 blocks.

1

10

61

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

M

INI

-C

OM

Recessed Modular Faceplate Patch Panels

Panduit-Pannet-html.html
background image

62

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Suggested Labels Solutions for TIA/EIA-606-A Compliance

Patch Panel

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer Label

CP16BL

C061X030FJJ

C061X030FJC

CP24BL
CP48BL
CP72BL
CP96BL
CP16WSBL
CP24WSBL
CP48WSBL

M

INI

-C

OM

All Metal Shielded Modular Patch Panels

Component Labels for 

M

INI

-C

OM

All Metal Shielded Modular Patch Panels

• Accept 

M

INI

-C

OM

Modules for grounded 

shielded applications

• Provide write-on areas for port identification
• Not recommended in applications where moves, adds and

changes are frequent

• Mount to standard TIA/EIA 19” rack or 23” racks with

optional extender bracket

• For non-shielded applications use 

M

INI

-C

OM

Modular

Patch Panels found on pages 57 - 61

CP16BL

CP24BL

CP48BL

CP72BL

CP24WSBL

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included.
Each patch panel includes the CPT tool to ease removal of 

M

INI

-C

OM

Shielded Jack Modules.

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

CP48WSBL

PGK

PGK96

PGKE

PGKE96

CP16WSBL

CP96BL

Part Number

Part Description

No. of 

Rack 

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

M

INI

-C

OM

All Metal Modular Patch Panels

CP16BL

16 port all metal modular patch panel.

1

1

10

CP24BL

24 port all metal modular patch panel.

1

1

10

CP48BL

48 port all metal modular patch panel.

2

1

10

CP72BL

72 port all metal modular patch panel. Rear cable
management is required to prevent twisting.

2

1

10

CP96BL

96 port all metal modular patch panel.

4

1

10

M

INI

-C

OM

All Metal Modular Patch Panels with Strain Relief Bar

CP16WSBL

16 port all metal modular patch panel with strain relief
bar.

1

1

10

CP24WSBL

24 port all metal modular patch panel with strain relief
bar.

1

1

10

CP48WSBL

48 port all metal modular patch panel with strain relief
bar.

2

1

10

Grounding Kits for All Metal Modular Patch Panel

PGK

Attaches CP**BL panel to grounding bus for use with
painted racks in shielded applications. Insulated #12
AWG stranded copper wire 200mm long

1

10

PGK96

Attaches CP**BL panel to grounding bus for use with
painted racks in shielded applications. Insulated #12
AWG stranded copper wire 2400mm long. Lug
installed on one end with additional lug included to cut
and crimp to desired length.

1

10

PGKE

Attaches CP**WSBL panel to grounding bus when
used with painted racks in shielded applications.
Insultated #10 AWG stranded copper wire 200mm
long.

1

10

PGKE96

Attaches CP**WSBL panel to grounding bus for use
with painted racks in shielded applications. Insulated
#10 AWG stranded copper wire 2400mm long. Lug
installed on one end with additional lug included to cut
and crimp to desired length.

1

10

C252X030FJJ

C252X030FJC

Panduit-Pannet-html.html
background image

Part Number

Part Description

No. of Rack

Spaces

^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

DP246X88TG

24 port Augmented Category 6, 10Gb/s patch
panel with 24 RJ45  8 position, 8 wire ports

1

1

50

DP486X88TG

48 port Augmented Category 6, 10Gb/s patch
panel with 48 RJ45  8 position, 8 wire ports

2

1

50

DPA246X88TG

24 port Augmented Category 6, 10Gb/s patch
panel with 24 RJ45  8 position, 8 wire ports

1

1

50

DPA486X88TG

48 port Augmented Category 6, 10Gb/s patch
panel with 48 RJ45  8 position, 8 wire ports

2

1

50

^One rack space = 44.45mm
Includes #12-24 and metric M6 bonding screws to mount and ground the patch panel to the rack.
Replacement punchdown modules available in standard colour (Black) – part number DRJ6X88TGBL.

DP246X88TG

DPA246X88TG

DP6

PLUS

Patch Panels

• Exceeds TIA/EIA-568-B.2-1 Category 6 and ISO11801 2nd

Edition Class E standards

• Each port is 100% tested to ensure NEXT and return 

loss performance and is individually serialised to 
support traceability

• Utilises 110 punchdown termination on back panel
• Each port contains a universal label that is colour coded for

T568A and T568B wiring schemes

• Angled patch panels facilitate proper bend radius control

and minimise the need for horizontal cable managers

• Terminates 4 pair, 22 – 24 AWG, 100 ohm, solid or

stranded twisted pair cable 

• Mount to standard EIA 19" rack or 23" racks with optional

extender bracket

• Write-on areas for port and panel identification available
• Can be clearly identified with labels and icons

DP12688TG

DP24688TG

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included.
89D Wall Mount Bracket available on page 61.
Replaceable punchdown modules available in standard colour (Black) – part number DRJ688TGBL.

DP48688TG

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

DP6

Plus Flat Patch Panels

DP12688TG

12 port, Category 6, patch panel with 12 RJ45, 8
position, 8 wire ports. Mounts to 89D wall 
mount bracket.

1

10

DP24688TG

24 port, Category 6, patch panel with 24 RJ45, 8
position, 8 wire ports.

1

1

10

DP48688TG

48 port, Category 6, patch panel with 48 RJ45, 8
position, 8 wire ports.

2

1

10

DP6

Plus Angled Patch Panels

DPA24688TG

24 port, Category 6, patch panel with 24 RJ45, 8
position, 8 wire ports.

1

1

10

DPA48688TG

48 port, Category 6, patch panel with 48 RJ45, 8
position, 8 wire ports.

2

1

10

DPA48688TG

63

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

DP6

10G

IG

Modular Punchdown Patch Panels

Panduit-Pannet-html.html
background image

64

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Component Labels for 

DP6

PLUS

Patch Panels

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Panel

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

All Patch Panels 
on this Page

C379X030FJJ

C379X030FJC

Suggested Label Solutions for TIA/EIA-606-A Compliance

All Patch 
Panels on 
this Page

C379X030FJJ

C379X030FJC

DP5e

Patch Panels

• Exceeds TIA/EIA-568-B.2 Category 5e and ISO11801 2nd

Edition Class D standards

• Angled patch panels facilitate proper bend radius control

and minimise the need for horizontal cable managers

• Utilises 110 punchdown termination on back panel
• Removable connector packs
• Integral cable tie mounts for improved cable management
• Mount to standard EIA 19" rack or 23" racks with optional

extender brackets 

• Write-on areas for port and panel identification

available with optional covers (DPLT and DPLF)

• Can be clearly identified with labels and icons
• Each port has a universal label colour-coded for T568A

and T568B wiring schemes

• Terminate with PDT110 Punchdown Tool
• Terminates 4 pair, 22 – 24 AWG, 100 ohm, solid and

stranded, unshielded twisted pair cable

DP125E88TG

^ One rack space = 44.45mm.
M6 and #12-24 mounting screws included.
Replaceable punchdown modules available in standard colour (Black) – part number DRJ5E88TGBL.

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

DP5e

Flat Patch Panels

DP125E88TG

12 port, Category 5e, patch panel with 12 RJ45, 
8 position, 8 wire ports. Mounts to 89D Wall 
Mount Bracket.

1

10

DP245E88TG

24 port, Category 5e, patch panel with 24 RJ45, 8
position, 8 wire ports.

1

1

10

DP485E88TG

48 port, Category 5e, patch panel with 48 RJ45, 8
position, 8 wire ports.

2

1

10

DP5e

Angled Patch Panels

DPA245E88TG

24 port, Category 5e, patch panel with 24 RJ45, 8
position, 8 wire ports.

1

1

10

DPA485E88TG

48 port, Category 5e, patch panel with 48 RJ45, 8
position, 8 wire ports.

2

1

10

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

DPA485E88TG

Component Labels for 

DP5e

Patch Panels

DP245E88TG

DP485E88TG

Patch Panel

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Themal Printer

D

ATA

-P

ATCH

10/100 Base-T Patch Panels

• Consists of female telco 50 pin/25 pair connectors with

VELCRO fasteners wired per RJ21 industry standard for
backward compatibility

• Each port is wired for 10/100 Base-T Ethernet utilising pins

1, 2, 3 and 6

• Category 5 Powersum rated (in the channel) when used

with 

PANDUIT

Category 5 25 pair cable assemblies

• Does not require use of a punchdown tool
• Mount to standard TIA/EIA 19” rack or 23” racks with

optional extender bracket

• Write-on areas for port and panel identification available

with optional covers (DPLT and DPLF)

• Can be clearly identified with labels and icons

DP24584TV25

DP48584TV25

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included.
VELCRO is a registered trademark of Velcro Industries B.V.

Part Number

Part Description

No. of 

Rack 

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

DP24584TV25

24 port patch panel.

1

1

10

DP48584TV25

48 port patch panel.

2

1

10

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

Panduit-Pannet-html.html
background image

Voice Patch Panel

• Consists of single female telco 50 pin / 25 pair connector

with VELCRO fasteners wired for common active 
voice equipment

• 24 RJ45 ports with pins 4 and 5 active in each port
• VELCRO screw connector accommodates 180, 110 or 90

degree patch cord connectors on back of patch panel

• Does not require use of a punchdown tool
• Mounts to standard TIA/EIA 19” rack or 23” racks with

optional extender bracket

• Write-on areas available for port identification
• Can be clearly identified with optional labels and icons

Part Number

Part Description

No. of 

Rack 

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

VP24382TV25

24 RJ45 port patch panel with pins 4 and 5 active in each
port and one female RJ21 connector on back of panel.

1

1

10

D

ATA

-P

ATCH

10/100 Base-T Cable Assemblies

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com
*All UTPCH8 parts on this page.

Self-Laminating Labels for 

D

ATA

-P

ATCH

10/100 Base-T Cable Assemblies

• Category 5 Powersum rated 25 pair 
• Connectorised Cable Assemblies are enhanced 

performance patch cords featuring 25 pair Powersum
Category 5 solid cable with Category 5 25 pair plugs on
either end

• System also includes Category 5 Powersum rated 25 pair

Hydra with Category 5, 25 pair male connectors on one
end and 12 Pan-Plug modular plugs terminated to 
the 10/100 Base-T Ethernet pins (1, 2, 3 and 6) on the
other end

• All cords are 100% factory tested for wiring sequence 

and continuity

Cable lengths of 2m, 3m and 5m are also available. Replace 8 in part number with desired lengths. For example:
UTPCH3MSR25 is a 3 metre straight and right 25 pair Connectorised Cable Assembly.

UTPCH8

UTPCH812PP25

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Panel

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

All UTPCH8*

S100X400FAJ

S100X400VAC

Part Number

Part Description

Length 

(M)

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

UTPCH8SR25

Straight, 110 right orientation.

2.4

1

10

UTPCH8SL25

Straight, 110 left orientation.

2.4

1

10

UTPCH8L25

Both 110 left orientation.

2.4

1

10

UTPCH8R25

Both 110 right orientation.

2.4

1

10

UTPCH8LR25

110 left 110 right.

2.4

1

10

UTPCH812PP25

12 Pan-Plug Modular Plugs, straight

2.4

1

10

65

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included.
VELCRO us a registered trademark of Velco Industries B.V.

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

Component Labels for 

D

ATA

-P

ATCH

10/100 Base-T Patch Panels

Suggested Label Solutions for  TIA/EIA-606-A Compliance

Patch Panel

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

DP24584TV25
DP48584TV25

C379X030FJJ

C379X030FJC

Panduit-Pannet-html.html
background image

66

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

SRBM19BL

Strain Relief Bars

Component Labels for Voice Patch Panels

• Mounts to standard TIA/EIA 19” rack
• Ideal for high density patch panels to support excess cable
• Includes radius edge at rear to provide optimal bend 

radius control

• Includes 

T

AK

-T

Y

Hook & Loop Cable Ties (6 pieces per

manager bar) to support 6 bundles of cables (up to 12
cables each) – 24,48 or 72 cables in up to 2RU

Coupler Patch Panels

• Mount to standard TIA/EIA (482.60mm) rack or

(584.20mm) racks with optional extender bracket

• Include write-on areas for panel identification
• Include pre-printed numbers for port identification

CP245E88BL

CP48BNCBL

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included.

#12-24 mounting screws included.

Part Number

Part Description

No. of 

Rack 

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CPKC24BL

24 port patch panel with 24 pre-installed RJ45
keystone couplers. Complies with Category 5e
channel performance requirements

1

1

10

CP48BNCBL

48 port patch panel with 48 pre-installed 75 ohm 
BNC couplers

1

1

10

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

SRB19BL

Cable strain relief bar extends 50mm off back of rack to support cables
in punchdown or modular applications.

1

10

SRBS19BL-X Cable strain relief bar supports cables in punchdown or modular

applications.

10

0

Part Number

Part Description

No. of 

Rack 

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

VP50384KBL

Voice Patch Panel 568A Category 3, 50 port, 8 pins
with 4 active (3,4,5, and 6). Black colour

1

1

10

Strain Relief Bars

1

10

^ One rack space = 44.45mm

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Panel

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

VP24382TV25

C379x030FJJ

C379X030FJC

Panduit-Pannet-html.html
background image

P

AN

-P

LUG

High Performance Modular Plugs

• Patented tangle free plug latch prevents snags and 

provides easy release saving time on frequent moves,
adds and changes

• Meets FCC Part 68 and exceeds IEC 

60603-7 specifications

• Used in UTPCH series patch cords providing Category 

5e performance

• Simplified termination due to a unique process which

requires no loading bar. Guide ramp facilitates easy 
conductor insertion and termination

• Contacts plated with 1.27 microns of gold
• Terminates 24 gauge stranded or solid conductor with max

conductor insulation diameter of 1mm

• Patented tangle free latch prevents snags and provides

easy release saving time on frequent moves, adds 
and changes

• Meets FCC Part 68 and exceeds IEC60603-7 specifications
• Used in UTPSP series patch cords providing Category 

6 performance

• Slender strain relief boot provides easy access in high 

density applications

• Integral pair manager optimises performance and 

consistency by reducing untwist at plug

• Contacts plated with 1.27 microns of gold
• Terminates 24 gauge stranded conductor with max. 

conductor insulation diameter of 1mm

To ensure optimal performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 

PLUS components.

Modular Plug Termination Tools

• WPT-8 arranges all eight conductors in the proper

sequence and provides proper gauge length for trimming
conductors for MP588

• MPT5-8 required for modular plug termination

WPT-8

MPT5-8

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

SP688-C

8 position, 8 wire modular plug featuring tangle free latch. 
MPT5-8 crimp tool required for termination.

100 1000

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

MP588-C

8 position, 8 wire modular plug featuring tangle free latch.  
MPT5-8 crimp tool required for termination.

100 1000

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Wire Prep Tool

WPT-8

Separates and holds conductors in position prior to insertion into
modular plug for termination. For use with 

P

AN

-P

LUG

Modular Plug

(MP588) only.

1

10

Modular Plug Installation Tools

MPT5-8

Crimp tool for TX6

PLUS and 

P

AN

-P

LUG

Modular Plugs.

1

67

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

TX6

PLUS

Modular Plug

Panduit-Pannet-html.html
background image

68

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

TX6

PLUS

Category 6 Patch Cords

• Exceeds TIA/EIA-568-B.2-1 Category 6 standard
• ETL tested and approved for Category 6 

component compliance

• Plug performance in centre of TIA/EIA component range,

ensuring interoperability and optimal performance

• Constructed of Category 6 24 AWG UTP stranded cable

and TX6

PLUS Modular Plugs for superior performance

• Plug contacts plated with 1.27 microns of gold for 

improved durability

• Patented tangle free latch prevents snags and provides

easy release, saving time on frequent moves, adds 
and changes

• Slender strain relief boot provides easy access in high 

density applications

• Integral pair manager optimises performance and 

consistency by reducing untwist at plug

• Labels on patch cords provide identification of performance

level, length and quality control number

• Each patch cord is 100% performance tested
• Offered in a variety of lengths and colours to meet 

individual length and colour coding requirements

‡For additional standard cable colours available from stock, add suffix BL (Black), BU (Blue), GR (Green), 
RD (Red), or YL (Yellow) VL (Violet) or OR (Orange)to end of part number. 
*Non-standard lengths available to order are 6, 7, 8, 9, 10, 15, 20, 25, 30, 35, 40m. Typical shipping lead time is
20 working days from receipt of order and minimum order quantity is 10 (1 carton each) for these lengths. 
To ensure optimal performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 PLUS 

components. These products are also available in LSZH material add on an L to the part number as follows 
UTPSPL1M for a 1m LSZH patch cord.

Part Number

Part Description

Cable

Colour

Length

(M)*

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

UTPSP1M

UTP stranded patch cord with TX-6

PLUS Category

6 Modular Plug on each end for use in a Category 
6 channel

Off

White

1

1

10

UTPSP2M

Category 6 patch cord with TX-6

PLUS Modular

Plug on both ends

Off

White

2

1

10

UTPSP3M

Category 6 patch cord with TX-6

PLUS Modular

Plug on both ends

Off

White

3

1

10

UTPSP4M

Category 6 patch cord with TX-6

PLUS Modular

Plug on both ends

Off

White

4

1

10

UTPSP5M

Category 6 patch cord with TX-6

PLUS Modular

Plug on both ends

Off

White

5

1

10

Part Number

Part Description

Length

M

Cable

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

UTP6X1M

1m

Off

White

1

10

UTP6X1.5M

1.5m

Off

White

1

10

UTP6X2M

Augmented Category 6 10Gb/s Patch Cord with

TX6

PLUS

Modular Plug on both ends

2m

Off

White

1

10

UTP6X2.5M

2.5m

Off

White

1

10

UTP6X3M

3m

Off

White

1

10

UTP6X5M

5m

Off

White

1

10

NOTE: All patch cords constructed of 24AWG solid copper cable.

For standard cable colour other than Off White, add suffix BU (Blue) to end of part number.

TX6

10G

IG

Patch Cords

• Plug performance in centre of TIA/EIA component range,

ensuring interoperability and optimal performance

• Plug contacts plated with 1.27 microns of gold for 

improved durability

• Patented tangle free latch prevents snags and provides

easy release, saving time on frequent moves, adds 
and changes

• Slender strain relief boot provides easy access in high 

density applications

• Integral pair manager optimises performance and 

consistency by reducing untwist at plug

• Labels on patch cords provide identification of performance

level, length and quality control number

• Each patch cord is 100% performance tested

Panduit-Pannet-html.html
background image

Self-Laminating Labels for 

TX6

PLUS

Patch Cords

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com
*All UTPSP parts on this page.

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Cord

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

All UTPSP*

S100X125FAJ

S100X125VAC

Self-Laminating Cable Marker Holders for Large Cables or Cable Bundles

• Quick and easy TIA/606A compliance for a wide range of

cables and cable bundles

• Can be applied as a wrap-around marker (parallel to cable)

or flag marker 45º or 90º to cable

• Attach with 

PANDUIT

Intermediate or Standard 

Cross-Section Cable Ties

• Can also be used with 

PANDUIT

8.4mm and 12.5mm

width 

T

AK

-T

Y

Hook and Loop Cable Ties in the 90º 

flag application

Order number of packages required in multiples of Std. Pkg. Qty.

SLCT-WH

SLCT-OR

Part Number

Part Description

Width 

Height 

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

SLCT-WH

White, self-laminating cable marker holder, 25
tags/pkg

76.20

33.30

1

4

SLCT-OR

Orange, self-laminating cable marker holder, 25
tags/pkg

76.20

33.30

1

4

SLCT-YL

Yellow, self-laminating cable marker holder, 25
tags/pkg

76.20

33.30

1

4

SLCT-IG

Grey, self-laminating cable marker holder, 25
tags/pkg

76.20

33.30

1

4

• Exceeds TIA/EIA 568-B.2 Category 6 standard
• ETL tested and approved for category 6 

component compliance

• Plug performance in centre of TIA /EIA component range

ensuring interoperability and optimal performance

• Constructed of 24 AWG shielded cable and TX6 

modular plugs

• Plugs contact are plated with 1.27 microns of gold

• Patented tangle free latch prevents snags and provide

easy release, saving time on moves, adds and changes

• Slender strain relief boot provides easy access in high 

density applications

• Labels on patch cords provide identification of performance

level, length and quality control number

Part Number

Part Description

Length

Metre

Cable

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

STP6X1MIG

Category 6 

10G

IG

Shielded Patch cords with 

P

AN

-P

LUG

Modular Plug with black boots on 

each end

1

Grey

1

10

STP6X2MIG

2

Grey

1

10

STP6X3MIG

3

Grey

1

10

STP6X5MIG

5

Grey

1

10

69

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Shielded 

10G

IG

LSZH Category 6 Patch Cords 

For additional standard colours available from stock, replace suffix (IG) with BL (Black) BU (Blue), GR (Green),

RD (Red), YL (Yellow), VL (Violet), or OR (Orange), at the end of the part number

Panduit-Pannet-html.html
background image

70

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Category 5e Patch Cords

• Exceeds TIA/EIA-568-B.2 Category 5e standard
• Patented tangle free latch prevents snags and provides

easy release, saving time on frequent moves, adds 
and changes

• Exceeds FCC Part 68 and IEC 60603-7 specifications

• Constructed of Category 5e 24 AWG UTP stranded cable

and 

P

AN

-P

LUG

Modular Plug for superior performance

• Plug contacts plated with 1.27 microns of gold for 

improved durability

‡For additional standard cable colours available from stock, add suffix BL (Black), BU (Blue), GR (Green), 
RD (Red) or YL (Yellow) VL (Violet) or OR (Orange) to end of part number. Minimum order quantity is 10 (1 carton
each) for these colours.

Part Number

Part Description

Length

(M)

Cable

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

UTPCH1M

1

Off

White

1

10

UTPCH1.5M

1.5

Off

White

1

10

UTPCH2M

Category 5e UTP stranded patch cord with 

P

AN

-P

LUG

modular plugs on both ends.

2

Off

White

1

10

UTPCH2.5M

2.5

Off

White

1

10

UTPCH3M

3

Off

White

1

10

UTPCH5M

5

Off

White

1

10

Part Number

Part Description

Length

Metre

Cable

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

STPC1MBBL

Category 5e Shielded Patch cords with 

P

AN

-P

LUG

Modular Plug with black boots on

each end

1

Grey

1

10

STPC2MBBL

2

Grey

1

10

STPC3MBBL

3

Grey

1

10

STPC5MBBL

5

Grey

1

10

Shielded Category 5e LSZH Patch Cords

• Exceeds TIA/EIA-568-B.2 Category 5e standard
• Constructed of Category 5e 24 AWG LSZL UTP

stranded cable and 

P

AN

-P

LUG

Modular Plug for 

superior performance

• Patented tangle free latch prevents snags and provides

easy release, saving time on moves, adds and changes

• Plug contacts plated with 1.27 microns 

of gold 

Component Labels for Self-Laminating Cable Marker Holders for Large
Cables or Cable Bundles

Suggested Label Solutions for TIA/EIA-606-A Compliance

Cable

Marker Holder

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

All SLCT*

C200X100FJJ

C200X100FJC

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com
*All SLCT parts on the previous page.

Panduit-Pannet-html.html
background image

GP6

PLUS

Category 6 High Density Kits

GP6

PLUS

Punchdown System

• Exceed TIA/EIA-568-B.2-1 Category 6 standard
• Ideal for use in cross connects and consolidation 

point applications

• Provides pre-packaged components necessary 

for termination

• Kit includes required quantity of bases and 4-pair 

connecting blocks, label holders and labels

• Highly visible colour-coded wiring slots ease wiring

• Exceeds TIA/EIA-568-B.2-1

Category 6 standard

• Increases wiring capacity by 44% over

standard 110 systems

• Accommodates round and crescent cable
• Uses industry standard 110 contacts and

assembly methods

GPKBW144

GPKBW432

Cable requirement : terminates most 22-26 AWG solid or stranded IWC wire with a 1.27mm OD, either PVC or
LSZH rated.
Termination tool available on page 30.
To ensure optimal performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 

PLUS components.

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

GPKBW144

144-pair (36 port) high density field termination kit with legs.

1

10

GPKBW432

432-pair (108 port) high density field termination kit with legs.

1

10

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com
*All UTPCH parts on the previous page.

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Cord

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

All UTPCH*

S100X125FAJ

S100X125VAC

Component Labels for 

GP6

PLUS

Systems

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com
‡For non-adhesive labelling solution, do not remove liner from label.

Suggested Label Solutions for TIA/EIA-606-A Compliance

Punchdown System

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

GPKBW144
GPKBW432

C788X050Y1J

C788X050Y1C

71

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Self-Laminating Labels for Category 5e Patch Cords

Panduit-Pannet-html.html
background image

72

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

GP6

PLUS

Category 6 Standard Density Kits

• Exceed TIA/EIA-568-B.2-1 Category 6 standard
• Ideal for use in cross connects and consolidation 

point applications

• Provides pre-packaged components necessary 

for termination

• Kit includes required quantity of bases and 4-pair 

connecting blocks, label holders and labels

• Highly visible colour-coded wiring slots ease wiring

GPKBW24

GPKBW72

Cable requirement : terminates most 22-26 AWG solid or stranded IWC wire with a 1.27mm OD, either PVC or
LSZH rated.
Termination tool available on page 76.
To ensure optimal performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 PLUS components.

For complete labelling solutions and product information, reference the Labelling and Administration section 
on pages 349-356 and www.panduit.com

GP6

PLUS

Category 6 High Density Rack Mount Panel Kits

• Exceed TIA/EIA-568-B.2-1 Category 6 standard
• Ideal for use in cross connects and consolidation 

point applications

• Provides pre-packaged components necessary 

for termination

• Includes required quantity of bases and 4-pair connecting

blocks, label holders and labels.

• Highly visible colour-coded wiring slots ease wiring
• Mount to standard TIA/EIA (482.6mm) racks

GPB2884R2

GPB2884R4WJ

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included.
Termination tool available in page 76.
Cable requirement : terminates most 22-26 AWG solid or stranded IWC wire with a 1.27mm OD, either PVC or
LSZH rated.
To ensure optimal performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 

PLUS components.
For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

GPKBW24

96-pair (24 port) base field termination kit with legs.

1

10

GPKBW72

288-pair (72 port) base field termination kit with legs.

1

10

Part Number

Part Description

No. of 

Rack 

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

GPB2884R2

Two 144-pair (36 port) bases premounted to a panel
with 4-pair connector kit included.

2

1

10

GPB2884R4WJ Two 144-pair (36 port) bases and jumper troughs

premounted to a panel with 4-pair connector kit
included.

4

1

10

Panduit-Pannet-html.html
background image

GPB484R2

GPB484R4WJ

• Exceed TIA/EIA-568-B.2-1 Category 6 standard
• Ideal for use in cross connects and consolidation 

point applications

• Provides pre-packaged components necessary 

for termination

• Includes required quantity of bases and 4-pair connecting

blocks, label holders and labels

• Highly visible colour-coded wiring slots ease wiring
• Mount to standard TIA/EIA (482.6mm) racks

^ One rack space = 44.45mm
M6 and #12-24 mounting screws included
Termination tool available on page 76.
Cable requirement: terminates most 22-26 AWG solid or stranded IWC wire with a 1.27mm max OD, either 
PVC or LSZH rated.
To ensure performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 PLUS components.

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

GP6

PLUS

Category 6 Connecting Blocks

• Exceed TIA/EIA-568-B.2-1 Category 6 standard
• Available in 4 or 5 pair connection blocks
• Highly visible colour-coded wiring slots ease wiring
• Can be terminated with single or multiple position 

punchdown tools

• Can be utilised with discrete wires or 

GP6

PLUS

patch

cord connector

• Constructed of UL 94V-0 high impact 

polycarbonate material

• Patented single piece robust construction
• Optional four pair retaining clip (GPRC4) available which

provides added conductor retention and minimises errors
during moves, adds and changes

GPCB5

Termination tool available on page 76
Cable requirement: terminates most 22-26 AWG solid or stranded IWC wire with a 1.27mm max OD, either PVC
or LSZH rated.
To ensure optimal performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 components.

GPCB4

Part Number

Part Description

No. of 

Rack 

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

GPB484R2

Two 96-pair (24 port) bases premounted to panel
with 4-pair connector kit included.

2

1

10

GPB484R4WJ

Two 96-pair (24 port) bases and jumper 
troughs premounted to panel with 4-pair 
connector kit included.

4

1

10

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

4-Pair Connecting Block

GPCB4-X

4-Pair Connecting Block

10

1000

GPCB4-C

4-Pair Connecting Block

100 1000

5-Pair Connecting Block

GPCB5-X

5-Pair Connecting Block

10

1000

GPCB5-C

5-Pair Connecting Block

100 1000

73

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

GP6

PLUS

Category 6 Standard Density Rack Mount Panel Kits

Panduit-Pannet-html.html
background image

74

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

GP6

PLUS

Category 6 High Density Bases

• Exceed TIA/EIA-568-B.2-1 Category 6 standard
• Ideal for use in cross connects and consolidation 

point applications

• Highly visible colour-coded wiring slots eases wiring

• Sturdy one piece design
• Available with or without mounting legs for a variety of

mounting options

• Multiple mounting holes available

GPB144-X

GPBW144-X

GPB432-X

Termination tool available on page 76.
For rack mount applications see page 78
Cable requirement: terminates most 22-26 AWG solid or stranded IWC wire with a 1.27mm max OD, either PVC or
LSZH rated.
To ensure optimal performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 

PLUS components.

GPBW432-X

GP6

PLUS

Category 6 Standard Density Bases

• Exceed TIA/EIA-568-B.2-1 Category 6 standard
• Ideal for use in cross connects and consolidation 

point applications

• Highly visible colour-coded wiring slots ease wiring

• Sturdy one piece design
• Available with or without mounting legs for a variety of

mounting options

• Multiple mounting holes available

GPB24-X

GPBW24-X

GPB72-X

GPBW72-X

Termination tool available on page 76.
For rack mount applications see page 78.
Cable requirement: terminates most 22-26 AWG solid or stranded IWC wire with a 1.27mm max OD, either PVC or
LSZH rated.
To ensure optimal performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 

PLUS components.

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

144-Pair (36 Port) Base

GPB144-X

Positions and holds UTP wire for termination with Category 6
connecting blocks.

10

144-Pair (36 Port) Base - With Legs

GPBW144-X

Positions and holds UTP wire for termination with Category 6
connecting blocks, includes mounting legs.

10

432-Pair (108 Port) Base

GPB432-X

Positions and holds UTP wire for termination with Category 6
connecting blocks.

10

432-Pair (108 Port) Base - With Legs

GPBW432-X

Positions and holds UTP wire for termination with Category 6
connecting blocks, includes mounting legs.

10

Part Number

Part Description

Std.

Pkg.

Qty.

96-Pair (24 Port) Base

GPB24-X

Positions and holds UTP wire for termination with Category 6 connecting
blocks.

10

96-Pair (24 Port) Base - With Legs

GPBW24-X

Positions and holds UTP wire for termination with Category 6 connecting
blocks, includes mounting legs.

10

288-Pair (72 Port) Base

GPB72-X

Positions and holds UTP wire for termination with Category 6 connecting
blocks.

10

288-Pair (72 Port) Base - With Legs

GPBW72-X

Positions and holds UTP wire for termination with Category 6 connecting
blocks, includes mounting legs.

10

Panduit-Pannet-html.html
background image

Termination tool available on page 76.
Cable requirement: terminates most 22-26 AWG solid or stranded IWC wire with a 1.27mm max OD, either PVC
or LSZH rated.
To ensure optimal performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 

PLUS components.
For labelling solutions, reference chart on pages 349-356.

Jumper Troughs

• Available with or without legs for a variety of 

mounting options

• Unique finger design maintains cable bend radius

• Provides optimum cable management when used with

GP6

PLUS

and 

P

AN

-P

UNCH

Bases

• Ideal for use in cross connects, consolidation point and wall

mount applications

• Tower provides vertical feeder cable management

• Supplied with tower, bases, 4-pair connecting blocks, label

and label holders

Part Number

Part Description

Std.

Pkg.

Qty.

GPKT724

288-pair (72 port) standard density GP6 PLUS Tower Kit.

1

Part Number

Part Description

Std.

Pkg.

Qty.

P110JTW-X

Jumper trough with legs

10

P110JT-X

Jumper trough

10

75

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

GP6

PLUS

Standard Density Tower Kits

Panduit-Pannet-html.html
background image

76

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

GP6

PLUS

Termination Tools and Accessories

GPDTM

GPST

GP6

PLUS

Patch Connectors

• Field terminable
• Cable clamp on cover facilitates easier wiring
• IDCs provide reliable, gas-tight connections
• Strain relief reduces stress on cable
• Contain two piece, snap together housing

• Polarised to prevent reverse installation to connector block
• Clear polycarbonate cover keeps conductors visible 

after termination

• Cover also provides proper wiring sequence

• Terminates wires on both cable and cross-connect sides of

110 connecting blocks

• Reversible blade provides option of terminating without 

cutting wire

• Five pair punchdown tool seats 4 or 5 pair 

connecting blocks

GPC5E1-X

GPC5E2-X

To ensure optimal performance, 

PANDUIT

recommends use with other 

PANDUIT

Category 6 

PLUS components.

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

4-Pair Punchdown Tool

GPDTM

Inserts and cuts off up to 4-pairs at a time, for use with 

GP6

PLUS

system only.

1

10

4-Pair Replacement Head Assembly

GPDTMH

Replacement head assembly for 

GP6

PLUS

4-pair Punchdown Tool.

1

10

4-Pair Replacement Blade

GPDTMB

Replacement blade for 

GP6

PLUS

4-pair Punchdown Tool.

1

10

Single Wire Punchdown Tool

GPST

Inserts and cuts off one wire at a time, for use with 

GP6

PLUS

system only.

1

Single Wire Replacement Blade

GPSTB

Replacement blade for GP6

PLUS

Single Wire Punchdown Tool.

1

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

GPC5E1-X

Terminates 1 pair 24 AWG solid or stranded cable.

10

100

GPC5E2-X

Terminates 2 pair 24 AWG solid or stranded cable.

10

100

Panduit-Pannet-html.html
background image

77

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-P

UNCH

110 Category 5e System Kits

• Exceed TIA/EIA-568-B.2 Category 5e standard
• Field terminable
• Ideal for use in cross connects and consolidation 

point applications

• Provide pre-packaged components necessary 

for termination

• Includes required quantity of bases and connecting blocks,

label holders and labels

• Available in 100 or 300 pair bases with 3, 4 or 5-pair 

connecting blocks

100 Pair

300 Pair

It is common practice to completely fill each 25-pair wire strip with connecting blocks. Each kit contains the 
adequate number of connecting blocks to do so. Example: P110KB1004 includes five 4-pair and one 5-pair 
connecting block per 25-pair wiring strip for a total of twenty 4-pair and four 5-pair connecting blocks as well as
two label holders and two white designation labels.

Termination tool available on page 83.
Cable requirement: terminates most 22-26 AWG solid of stranded IWC wire with a 1.27mm max OD, either PVC
or LSZH rated.

Component Quantity per 

P

AN

-P

UNCH

110 Category 5e Kits

Bases

Connecting Blocks

Label Holders

Labels

P110BW300

Part Number

P110BW100

P110CB3

P110CB4

P110CB5

P110LH

DSL110

P110KB1004

1

20

4

2

2

P110KB1005

1

20

2

2

1

P110KB3004

60

12

6

6

1

P110KB3005

60

6

6

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

100 Pair Termination Kits

P110KB1004

Field terminated. Includes a base, 4-pair connector kit with five 4-pair
connectors and one 5-pair connector per row of 25 pairs, two-label
holders, and two white designation labels.

1

10

P110KB1005

Field terminated. Includes a base, 5-pair connector kit with five 5-pair
connectors per row of 25 pairs, two-label holders, and two white
designation labels.

1

10

300 Pair Termination Kits

P110KB3004

Field terminated. Includes a base, 4-pair connector kit with five 4-pair
connectors and one 5-pair connector per row of 25 pairs, two-label
holders, and two white designation labels.

1

10

P110KB3005

Field terminated. Includes a base, 5-pair connector kit with five 5-pair
connectors per row of 25 pairs, two-label holders, and two white
designation labels.

1

10

Panduit-Pannet-html.html
background image

78

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Punchdown Rack Mount Panels

• Accept punchdown bases for rack mount applications

P110B100R2B

P110B100R4B

P110B100R2

P110B100R4WJ

^ One rack space = 44.45mm
Includes mounting screws

P

AN

-P

UNCH

Category 5e 19” Rack Mount Panels

• Exceeds TIA/EIA-568-B.2 Category 5e standard
• Ideal for use in cross connects and consolidation 

point applications

• Mount to standard TIA/EIA 19” racks

• Exclusive deeper channel to facilitate TIA/EIA Category 5e

cabling installations

• Ideal for use in cross connects and consolidation 

point applications

^ One rack space = 44.45mm
Includes mounting screws.
Termination tool available on page 83.
For connecting blocks see page 80.
For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

P110B1004R2

P110B1004R4WJ

P

AN

-P

UNCH

Category 5e 19” Rack Mount Panel Kits

• Exceed TIA/EIA-568-B.2 Category 5e standard
• Field terminable
• Ideal for use in cross connects and consolidation

point applications

• Provide pre-packaged components necessary

for termination

• Includes required quantity of bases and connecting blocks,

label holders and labels

• Available with 4 or 5-pair connecting blocks

^ One rack space = 44.45mm
Includes mounting screws.
Termination tool available on page 83.

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Rack Mount Panel Kit with Bases and Connecting Blocks

P110B1004R2

Two 100 pair bases premounted to panel. 4-pair
connector kit included with five 4-pair connectors and
one 5-pair connector per row of 25 pairs.

2

1

10

P110B1005R2

Two 100 pair bases premounted to panel. 5-pair
connector kit included with five 5-pair connectors per
row of 25 pairs.

2

1

10

Rack Mount Panel Kit with Bases, Connecting Blocks and Jumper Troughs

P110B1004R4WJ

Two 100 pair bases and jumper troughs premounted
to 19”  rack mount panel. 4-pair connector kit included
with five 4-pair connectors and one 5-pair connector
per row of 25 pairs.

4

1

10

P110B1005R4WJ

Two 100 pair bases and jumper troughs premounted
to 19” rack mount panel with 5-pair connector kit
included with five 5-pair connectors per row of 
25 pairs.

4

1

10

Part Number

Part Description

No. of Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

P110B100R2

Two 100 pair bases premounted to panel.

2

1

10

P110B100R4WJ

Two 100 pair bases with jumper troughs
premounted to panel.

4

1

10

Part Number

Part Description

No. of Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

P110B100R2B

Panel accepts up to 2 RU of punchdown bases.

2

1

10

P110B100R4B

Panel accepts up to 4 RU of punchdown bases.

4

1

10

Panduit-Pannet-html.html
background image

79

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-P

UNCH

110 Category 5e Tower System

• Provides a complete cross-connect system
• Designed for wall mount applications
• Available in 300 and 900 pair configurations with 3, 4 or 

5-pair connecting blocks

• Supplied jumper troughs provide horizontal 

cable management

• Tower provides vertical feeder cable management

P110KT300

Each tower system contains adequate connecting blocks to complete each 25-pair wiring strip. Example:
P110KT3004 includes five 4-pair and one 5-pair connecting block per 25-pair wiring strip for a total of sixty 4-pair
and twelve 5-pair connecting blocks.

GP6

PLUS

system can be installed on individual towers, not recommended for use with 

GP6

PLUS

high 

density bases.
Termination tool available on page 83.
Cable requirement: terminates most 22-26 AWG solid or stranded IWC wire with a 1.27mm OD, either PVC or
LSZH rated.
For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

Vertical Cable Managers for Tower Systems

• Finger design allows for easy changes
• Can be mounted between towers
• Compatible with 

GP6

PLUS

or 110 Tower Systems

• Designed for wall mount or 19” rack 

mount applications

• Facilitates vertical cable management
• Rugged, all metal construction

P110VCM300

P110VCM

P110VCM900

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Vertical Cable Manager For Use With 300 Pair Tower System

P110VCM300 Mounts adjacent to 300 pair tower system.

Black

1

Vertical Cable Manager For Use With 900 Pair Tower System

P110VCM900 Mounts adjacent to 900 pair tower system.

Black

1

Vertical Cable Manager For Use With Backboard Mounting

P110VCM

Mounts to plywood backboard and adjacent to bases and jumper
troughs. White metal backboard and large D-rings, designed for
wall mount vertical or horizontal cable management.

White

1

Part Number

Part Description

Std.

Pkg.

Qty.

P

AN

-P

UNCH

300 Pair Tower Kits

P110KT3004

Convenient packaging includes all of the components required to completely
wire a 110 base.

1

P110KT3005

1

P

AN

-P

UNCH

900 Pair Tower Kits

P110KT9004

Convenient packaging includes all of the components required to completely
wire a 110 base.

1

P110KT9005

1

P

AN

-P

UNCH

Towers

P110T300

300 pair tower. Components sold separately.

1

P110T900

900 pair tower. Components sold separately.

1

Panduit-Pannet-html.html
background image

80

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

19” Rack Mount Bracket Kits

• Used to attach Tower Systems and Vertical Cable

Managers to 19”

• Use two towers side by side or a tower and a vertical wire

manager side by side

• Includes brackets and mounting screws

P

AN

-P

UNCH

110 Category 5e Connecting Blocks

• Exceeds TIA/EIA-568-B.2 Category 5e standard
• Available in 3, 4 or 5 pair connection blocks
• Dual IDC terminates UTP cable on 110 base and UTP

cable or 110 patch cords for cross connecting

• Highly visible colour-coded wiring slots ease wiring
• Can be used with single or multiple punchdown tools

• Can be utilised with discreet wires or 

P

AN

-P

UNCH

patch

cord connector

• Constructed of UL 94V-0 high impact 

polycarbonate material

• Patented single piece robust construction

P110CB3

P110CB5

P110CB4

Termination tool available on page 83.
Cable requirement: terminates most 22-26 AWG solid or stranded IWC wire with a 1.27mm max OD, either PVC
or LSZH rated.

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

3-Pair 110 Connecting Blocks

P110CB3-X

3-pair connecting block.

10

1000

P110CB3-C

100 1000

4-Pair 110 Connecting Blocks

P110CB4-X

4-pair connecting block.

10

1000

P110CB4-C

100 1000

5-Pair 110 Connecting Blocks

P110CB5-X

5-pair connecting block.

10

1000

P110CB5-C

100 1000

Part Number

Part Description

Std.

Pkg.

Qty.

P110TB300

Kit for 300-pair tower or vertical wire management.

1

P110TB900

Kit for 900-pair tower or vertical wire management.

1

Panduit-Pannet-html.html
background image

81

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-P

UNCH

110 Category 5e Bases

• Exclusive deeper channel to facilitate TIA/EIA Category 5e

cabling installations

• Ideal for use in cross connects and consolidation point

applications

• Available with or without legs for various mounting options
• Sturdy one piece design
• Highly visible colour coded wiring strip

P110BW100-X

P110BW300-X

P110B100-X

P110B300-X

Cable requirement: terminates most 22-26 AWG solid or stranded IWC wire with a 1.27mm max OD, either PVC
or LSZH rated.

Jumper Troughs

• Available with or without legs for a variety of 

mounting options

• Unique finger design maintains cable bend radius

• Provides optimum cable management when used with

GP6

PLUS

and 

P

AN

-P

UNCH

Bases

Punchdown Designation Label Holder

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

P110LH

Label holder snaps into standard and high density 110 bases

6

60

Part Number

Part Description

Std.

Pkg.

Qty.

P110JTW-X

Jumper trough with legs

10

P110JT-X

Jumper trough

10

Part Number

Part Description

Std.

Pkg.

Qty.

100 Pair Base - With Legs

P110BW100-X

Positions and holds UTP cable for termination with 

P

AN

-P

UNCH

110

Connecting Blocks. Legs allow cables to be routed behind bases.

10

300 Pair Base - With Legs

P110BW300-X

Positions and holds UTP cable for termination with 

P

AN

-P

UNCH

110

Connecting Blocks. Legs allow cables to be routed behind bases.

10

100 Pair Base

P110B100-X

Positions and holds UTP cable for termination with 

P

AN

-P

UNCH

110

Connecting Blocks. For frame or rack mount wiring behind bases.

10

300 Pair Base 

P110B300-X

Positions and holds UTP cable for termination with 

P

AN

-P

UNCH

110

Connecting Blocks. For frame or rack mount wiring behind bases.

10

Panduit-Pannet-html.html
background image

82

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com
‡For non-adhesive labelling solution, do not remove liner from label.

Component Labels for 110 Punchdown Designation Label Holders

Suggested Label Solutions for TIA/EIA-606-A Compliance

Punchdown System

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

P110LH

C750X050Y1J

C750X050Y1C

Self-Laminating Labels for 

GP6

PLUS

Patch Cord Assemblies

GP6

PLUS

Patch Cord Assemblies

GPPC4IG*B

GPPC4IG*A

GPPC4IG

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Cord

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

All GPPC4IG*

S100X125FAJ

S100X125VAC

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

Part Number

Part Description

Length

M

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

GPPC4IG2M

One 4 pair 

GP6

PLUS

Connector on each end.

2

1

10

GPPC4IG2MA

One 4 pair 

GP6

PLUS

Connector wired to a RJ45 

P

AN

-P

LUG

568A Wiring.

2

1

10

GPPC4IG3MA

3

1

10

GPPC4IG2MB

One 4 pair 

GP6

PLUS

Connector wired to a RJ45 

P

AN

-P

LUG

568B Wiring.

2

1

10

GPPC4IG3MB

3

1

10

Panduit-Pannet-html.html
background image

83

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-P

UNCH

Punchdown Tools and Accessories

Self-Laminating Labels for 

G

IGA

-P

UNCH

1 and 2 Pair

Patch Cord Assemblies

• Terminate wires on both cable and cross-connect sides of

110 connecting blocks

• Reversible blade provides option of terminating without 

cutting wire

• Five pair punchdown tool seats 3, 4 or 5-pair connecting

blocks onto 110 base

PDT110M

PDT110

G

IGA

-P

UNCH

1 and 2 Pair Patch Cord Assemblies

• Factory assembled patch cord assembly
• Ideal for use in cross connect applications

• Available in a variety of lengths

GPPC2IG

GPPC1IG

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Cord

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

All GPPC*

S100X125FAJ

S100X125VAC

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

5-Pair Punchdown Tool

PDT110M

5-pair punchdown tool, can terminate up to 5 pairs at a time.

1

10

Replacement Blade

PDH110M

Replacement head assembly for 5-pair punchdown tool.

1

10

Replacement Head Assembly

PDB110M

Replacement blade for 5-pair punchdown tool.

1

10

Single Punchdown Tool

PDT110

Punchdown tool and blade for 110 style IDCs.

1

Replacement Blade

PDTH110

Replacement blade for single pair punchdown tool.

1

Part Number

Part Description

Length

M

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

GPPC1IG2M

One 1 pair 

G

IGA

-P

UNCH

Connector on each end. Meets

Category 5e performance requirements.

2

1

10

GPPC1IG3M

3

1

10

GPPC2IG2M

One 2 pair 

G

IGA

-P

UNCH

Connector on each end. Meets

Category 5e performance requirements.

2

1

10

Panduit-Pannet-html.html
background image

84

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

-P

UNCH

110 Patch Cord Assemblies

Self-Laminating Labels for 

G

IGA

-P

UNCH

1 and 2 Pair

Patch Cord Assemblies

For other lengths replace last number in part number with desired metre length 0.5, 1, 1.5, 2, 3, 5 or 6.

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

• Factory assembled patch cord assembly
• Ideal for use in cross connect applications

• Available in a variety of lengths

P

AN

-P

UNCH

110 Patch Connectors

• Contains two piece, snap together housing
• Field terminable
• Cable clamp on cover provides easier wiring
• IDC’s provide reliable gas-tight connections

• Strain relief reduces stress on cable
• Polarised to prevent reverse installation to connector block
• Clear polycarbonate cover keeps conductors visible 

after termination

P110PC1-X

P110PC2-X

P110PC3-X

P110PC4-X

P110PC4

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Cord

Part Number

Laser/Ink Jet Desktop

Printer Label

P

ANTHER

LS8

Hand-Held Thermal Printer

P110PC1&2

S100X125FAJ

S100X125VAC

S100X150FAJ

S100X150VAC

Part Number

Part Description

Length

M

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

P110PC1IG.5M

1-pair 110 connector on each end. Meets Category 3
performance requirements.

.5

1

10

P110PC1IG1M

1

1

10

P110PC1IG1.5M

1.5

1

10

P110PC1IG2M

2

1

10

P110PC1IG3M

3

1

10

P110PC1IG5M

5

1

10

P110PC1IG6M

6

1

10

P110PC2IG.5M

2-pair 110 connector on each end. Meets Category 5
performance requirements.

.5

1

10

P110PC2IG1M

1

1

10

P110PC2IG1.5M

1.5

1

10

P110PC2IG2M

2

1

10

P110PC2IG3M

3

1

10

P110PC2IG5M

5

1

10

P110PC4IG1M

4-pair 110 connector on each end. Meets Category 5e
performance requirements.

1

1

10

P110PC4IG2M

2

1

10

P110PC4IG3M

3

1

10

P110PC4IG5M

5

1

10

P110PC4IG1MA

4-pair 110 connector to 

P

AN

-P

LUG

RJ45 modular 

plug - T568A wired. Meets Category 5e performance
requirements.

1

1

10

P110PC4IG2MA

2

1

10

P110PC4IG3MA

3

1

10

P110PC4IG5MA

5

1

10

P110PC4IG1MB

4-pair 110 connector to 

P

AN

-P

LUG

RJ45 modular 

plug - T568B wired. Meets Category 5e performance
requirements.

1

1

10

P110PC4IG2MB

2

1

10

P110PC4IG3MB

3

1

10

P110PC4IG5MB

5

1

10

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

P110PC1-X

Terminates 1 pair, 24 AWG solid or stranded cable.

10

100

P110PC2-X

Terminates 2 pairs, 24 AWG solid or stranded cable.

10

100

P110PC3-X

Terminates 3 pairs, 24 AWG solid or stranded cable.

10

100

P110PC4-X

Terminates 4 pairs, 24 AWG solid or stranded cable.

10

100

Panduit-Pannet-html.html
background image

85

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Cable

Colour

Cable

Length

Metre

Std.

Pkg.

Qty.

Std.

Plt.

Qty.

PANDUIT

TX

5500

Category 5e UTP Copper Cable

• Category 5e UTP Cable constructed with 24 AWG copper

conductors with Polyethylene insulation

• 4 twisted pairs are laid into a flame retardant PVC or 

LSZH jacket

• Exceeds ISO/IEC 11801 2nd Edition Class D and TIA/EIA-

568-B.2 standards

• Cable is placed in 305m boxes

Part Number

Part Description

PVC

PUC5504LG-E

4 Pairs 24AWG UTP copper cable with PVC
outer jacket

Light
Grey

LSZH

PUL5504WH-E

4 Pairs 24AWG UTP copper cable with LSZH
outer jacket

White

305

305

1 box

1 box

20

boxes

20

boxes

PANDUIT TX

5500

Category 5e FTP Copper Cable

• Category 5e FTP Cable constructed with 24 AWG copper

conductors with Polyethylene insulation

• 4 twisted pairs are wrapped in foil and covered by an over-

all metal braid

• Outer jacket is constructed with flame retardent PVC or

LSZH material

• Exceeds ISO/IEC 11801 2nd Edition Class D and TIA/EIA-

568-B.2 standards

• Cable is placed on 500m Reels

Cable

Colour

Cable

Length

Metre

Std.

Pkg.

Qty.

Std.

Plt.

Qty.

Part Number

Part Description

PVC

PFC5504LG-ED

4 Pairs 24AWG FTP copper cable with PVC
outer jacket

Light
Grey

LSZH

PFL5504DG-ED

4 Pairs 24AWG FTP copper cable with LSZH
outer jacket

Dark
Grey

500

500

1 reel

1 reel

20

boxes

20

boxes

PANDUIT TX

5500

Category 5e S/FTP Copper Cable

• Category 5e FTP Cable constructed with 24 AWG copper

conductors with Polyethylene insulation

• 4 twisted pairs are wrapped in foil and covered by an over-

all metal braid

• Outer jacket is constructed with flame retardent PVC or

LSZH material

• Exceeds ISO/IEC 11801 2nd Edition Class D and TIA/EIA-

568-B.2 standards

• Cable is placed on 500m Reels

Cable

Colour

Cable

Length

Metre

Std.

Pkg.

Qty.

Std.

Plt.

Qty.

Part Number

Part Description

PVC

PSFC5504LG-ED

4 Pairs 24AWG SFTP copper cable with PVC
outer jacket

Light
Grey

LSZH

PSFL5504DG-ED

4 Pairs 24AWG SFTP copper cable with
LSZH outer jacket

Dark
Grey

500

500

1 reel

1 reel

20

boxes

20

boxes

Panduit-Pannet-html.html
background image

86

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

PANDUIT

TX

6000

Category 6 FTP Copper Cable

• Category 6 FTP Cable constructed with 24 AWG copper

conductors with Polyethylene insulation

• 4 twisted pairs are wrapped in foil, separated by a spline,

and laid into a flame retardant PVC or LSZH jacket

• Exceeds ISO/IEC 11801 2nd Edition Class E and TIA/EIA-

568-B.2-1 standards

• Cable is placed on 500m Reels

Cable

Colour

Cable

Length

Metre

Std.

Pkg.

Qty.

Std.

Plt.

Qty.

Part Number

Part Description

PVC

PFC6004LG-ED

4 Pairs 24 AWG FTP copper cable with PVC
outer jacket

Light
Grey

LSZH

PFL6004DG-ED

4 Pairs 24 AWG FTP copper cable with
LSZH outer jacket

Dark
Grey

500

500

1 reel

1 reel

6

reels

6

reels

PANDUIT TX

6000

Category 6 SFTP Copper Cable

• Category 6 SFTP Cable constructed with 24 AWG copper

conductors with Polyethylene insulation

• 4 twisted pairs are wrapped in foil, covered by a metal

braid and separated by a spline

• Cable outer jacket is constructed with a flame retardant

PVC or LSZH material  

• Exceeds ISO/IEC 11801 2nd Edition Class E and TIA/EIA-

568-B.2-1 standards

• Cable is placed on 500m Reels

Cable

Colour

Cable

Length

Metre

Std.

Pkg.

Qty.

Std.

Plt.

Qty.

Part Number

Part Description

PVC

PSFC6004LG-ED

4 Pairs 24 AWG SFTP copper cable with
PVC PVC outer jacket

Grey

500

1 reel

6

reels

PSFL6004DG-ED

4 Pairs 24 AWG SFTP copper cable with
LSZH outer jacket

Dark
Grey

500

1 reel

6

reels

LSZH

PANDUIT

TX

6000

Category 6 UTP Copper Cable

• Category 6 UTP Cable constructed with 23 AWG copper

conductors with Polyethylene insulation

• 4 twisted pairs are wrapped in foil, separated by a spline,

and laid into a flame retardant PVC or LSZH jacket

• Exceeds ISO/IEC 11801 2nd Edition Class E and TIA/EIA-

568-B.2-1 standards

• Cable is placed on 500m Reels

Cable

Colour

Cable

Length

Metre

Std.

Pkg.

Qty.

Std.

Plt.

Qty.

Part Number

Part Description

PVC

PFC6004LG-ED

4 Pairs 23 AWG FTP copper cable with PVC
outer jacket

Light
Grey

LSZH

PFL6004DG-ED

4 Pairs 23 AWG FTP copper cable with
LSZH outer jacket

Dark
Grey

500

500

1 reel

1 reel

6

reels

6

reels

Panduit-Pannet-html.html
background image

87

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

PANDUIT T

X

6

10

GIG

UTP Copper Cable

• The 

10G

IG

UTP Cable is constructed with 23 AWG copper

conductors with Polyethylene insulation

• 4 twisted pairs are separated by a spline and an additional

wire separates cables from each other improving ANEXT

• Meets or exceeds ISO/IEC 11801-2nd Edition Class E and

TIA/EIA-568-B.2-1 standards

• Cable is placed on 305 metre reels
• Cable outer jacket is constructed with a flame retardant

LSZH material

Cable

Colour

Cable

Length

Metre

Std.

Pkg.

Qty.

Std.

Plt.

Qty.

Part Number

Part Description

LSZH

PUL6X04WH-E

4 Pairs 23 AWG UTP copper cable with
LSZH outer jacket

White

305

1 reel

-

PANDUIT TX

7000 10

GIG

Category 7 600 

MH

z

S-STP Copper Cable

• Category 7 S-STP Cable constructed with 23 AWG copper

conductors with Polyethylene insulation

• 4 twisted pairs are individually wrapped in foil
• Cable outer jacket is constructed with a flame retardant

LSZH material  

• Meets or exceeds ISO/IEC 11801 2nd Edition Class E and

TIA/EIA-568-B.2-1 standards

• Cable is placed on 500m Reels

Cable

Colour

Cable

Length

Metre

Std.

Pkg.

Qty.

Std.

Plt.

Qty.

Part Number

Part Description

LSZH

PSFL6004DG-ED

4 Pairs 23 AWG S-STP copper cable with
LSZH outer jacket

Dark
Grey

500

1 reel

6

reels

Panduit-Pannet-html.html
background image

88

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

NOTES

Panduit-Pannet-html.html
background image

89

F

IBRE

C

ONNECTORS

, E

NCLOSURES

A

ND

P

ATCH

C

ORDS

PANDUIT

offers a full line of innovative fibre connectivity products that meet the most demanding

industry requirements for data and telecommunication applications.

PANDUIT

fibre systems provide

modular solutions for applications including LANs, Public Networks, Storage Area Networks,

Fibre-to-the-desk and 10Gb/s Ethernet. End-to-end high performance solutions are available for 

central offices, data centers, telecommunication rooms, workstations, and entrance facilities.

The 

PANDUIT

fibre system includes a diverse selection of connectors, adapter modules, adapter

panels, enclosures, patch cords, cable assemblies and accessories for both singlemode and

multimode applications. These fibre system components provide the greatest value by assuring

reliability and providing the foundation for future network growth. Achieve total fibre integration

now and for the future by installing 

PANDUIT

fibre end-to-end system solutions.

Adaptable system design provides flexibility for
current and future network growth

Modular high-density design maximises valuable

space and simplifies system updates

Compatible with 

M

INI

-C

OM

products for 

complete modularity

Fast, easy field installation of system components at
the lowest installed cost 

Creates a complete fibre management system that
effectively manages fibre optic connectivity

Complete line of fibre connectivity to fit your specific
network strategy

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

90

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

1

2

3

Fibre Optic Enclosures, Trays, Fibre

Adapter Panels and

Pre-terminated Cassettes

(pages 106-117)

Fibre Optic Connectors,

FJ

Jack Modules and Plugs

SC, ST*, LC, FJ

(pages 95 - 97)

Fibre Optic Adapters

SC, LC

(pages 95 - 98)

Fibre Optic Connectors, Enclosures and Patch Cords Roadmap

3

Wall Mount
Enclosure

Rack Mount

Enclosure

5

6

Fibre

Adapter

Panel

3

3

4

To Workstation or

Telecommunication

Room (IDF)

* ST is a registered trademark of Lucent Technologies

Fibre Optic
Patch Cord

Panduit-Pannet-html.html
background image

91

4

5

6

Fibre Routing

(pages 195-231)

Fibre Optic Patch Cords

and Cable Assemblies

(pages 118-127)

Workstation

Area

Fibre-to-the-Desk

M

INI

-C

OM

TM

FJ

Duplex Jack Module in

M

INI

-C

OM

TM

Sloped Faceplate

(Recommended at Workstation Outlet)

Fibre Optic
Patch Cord

FJ Jack Module

FJ Jack

Module

1

4

Fibre Optic
Patch Cord

1

Racks and Cable Management

(pages 131-157)

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

92

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

*ST is a registered trademark of Lucent Technologies

ST*

O

PTI

-C

RIMP

Fibre Optic Connectors - Pre-polished Crimp

• FOCIS-2 TIA/EIA-568-B.3 compatible connector
• Insertion loss: 0.3dB typical (62.5/125m), 0.35dB typical

(50/125m)

• Return loss: >20dB
• Pre-polished mechanical crimp termination eliminates 

polishing and adhesive, reducing installation time by 50%
over field polish ST connectors

• Mechanical crimp cable retention consistently provides

higher than industry standard cable retention

• ST

O

PTI

-C

RIMP

connectors and crimp tool allow visual 

verification of optimal continuity during crimp termination
with the FVFLKIT Visual Fault Locator Kit (included in
FJMVKIT Termination Kit)

• Each connector includes connector body/ferrule assembly

with pre-polished fibre stub, spring, bayonet, crimp sleeve,
one boot for 900m buffered fibre, one boot for 3mm 
jacketed cable and one dust cap

• Fibre cable type: tight-buffered only
• Fibre cable size: 3.0mm jacketed cable or 900μm 

tight-buffered fibre

• Ferrule type: 2.5mm zirconia ceramic 

(highest durability for repeated matings)

• Use 

O

PTI

-C

RIMP

Termination Kit (FJMVKIT) on page 107

FSTMMBL

FSTMMRD

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FSTMMBL

ST* 

O

PTI

-C

RIMP

62.5/125μm multimode fibre optic connector

Black

1

10

FSTMMRD

Red

1

10

FSTMM50BL

ST* 

O

PTI

-C

RIMP

50/125μm multimode fibre optic connector

Black

1

10

FSTMM50RD

Red

1

10

OPTICAM

ST* Fibre Optic Connectors - Field Polish

• FOCIS-2 TIA/EIA-568-B.3 compatible connector
• Insertion loss: 0.15dB typical (multimode), 0.20dB typical

(singlemode)

• Return loss: >20dB (multimode), >40dB (singlemode)
• Each connector includes metal connector body/ferrule

assembly, spring, metal bayonet, crimp sleeve, one boot
for 900μm buffered fibre, one boot for 3mm jacketed cable
and one dust cap

• Fibre cable type: tight-buffered recommended
• Fibre cable size: 3.0mm jacketed cable or 900μm 

buffered fibre

• Ferrule type: 2.5mm zirconia ceramic 

(highest durability for repeated matings)

• Field polish termination — 

PANDUIT

recommends 

anaerobic adhesive on page 109

• Use Field Polish Termination Kit (FJKITG) on page 109

FSTMABL

FSTMARD

FSTSABU

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FSTMABL

ST* multimode fibre optic connector — 62.5/125μm or
50/125μm fibre.

Black

1

10

FSTMARD

Red

1

10

FSTSABU

ST* singlemode fibre optic connector.

Blue

1

10

M

INI

-C

OM

ST* Fibre Optic Adapter Modules

• FOCIS-2 TIA/EIA-568-B.3 compatible adapter
• Compatible with 

M

INI

-C

OM

products for 

complete modularity

• Can be used with multimode or singlemode connectors and

patch cords

M

INI

-C

OM

ST* Simplex Adapter Modules are commonly

used with 

M

INI

-C

OM

Patch Panels

• Choice of phosphor bronze or zirconia ceramic split sleeves

to fit specific network requirements; zirconia ceramic split
sleeves are required for singlemode performance

• ST* Simplex Adapters are also available in patch panels 

or fibre adapter panels to provide a complete ST* 
system solution

CMSTZ

‡ For other colours replace suffix AW (Arctic White) or BU (Blue) with BL (Black), IW (Off White), or 
EI (Electric Ivory).*ST is a registered trademark of Lucent Technologies

Part Number

Part Description

No. of

Module
Spaces

Module

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMSTAW

Module supplied with one ST* multimode fibre
optic adapter with phosphor bronze split sleeve.

1

Arctic
White

1

10

CMSTZBU

Module supplied with one ST* singlemode fibre
optic adapter with zirconia ceramic split sleeve.

1

Blue

1

10

Panduit-Pannet-html.html
background image

93

LC 

O

PTI

C

AM

Fibre Optic Connectors 

Pre-Polished Cam Termination

• TIA/EIA-604 FOCIS-10 compatible connectors
• Exceed TIA/EIA-568-B.3 requirements
• Insertion loss: .40dB typical (multimode and singlemode)
• Return loss: >20dB (multimode), >50dB (singlemode) 
• Spring-loaded “Senior” rear pivot latch LC connector  
• Quick installation, greater than 50% faster than

conventional epoxy connectors, with high
performance/yield

• Cam termination design allows multiple field

fibre re-terminations 

• Factory pre-polished fibre endface simplifies termination

method over standard field polish connectors

• No consumable materials required
• Non-optical disconnect maintains data transmission under

tensile loads for jacketed cable

• Mechanical crimp cable retention consistently provides

higher than industry standard cable retention

• Cam activated fibre and buffer clamp mechanisms provide

superior fibre and buffer retention — less sensitivity to fibre
tensile loading

• No separate clamps, tools or steps are required to secure

both the fibre and the buffer

• Fibre cable type: tight-buffered only
• Fibre cable size: 900μm tight-buffered fibre with included

boot(s); 1.6mm – 2.0mm and 3.0mm jacketed cable with
available 

O

PTI

C

AM

1.6mm/2.0mm and 3.0mm Boot(s) —

10 per package

• Ferrule type: 1.25mm zirconia ceramic (highest durability 

for repeated matings)

• Available visual fault locator integrated into the termination

tool (OCTT) to simplify tooling and termination 

• Use one of the Pre-Polished Termination Kits on

page 106

FLCDMCXAQ

FLCDMC6BL

FLCSSCBU

FLCCLIPBL-L

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

LC 

O

PTI

C

AM

10G

IG

50/125μm Multimode Fibre Optic Connectors

FLCSMCXAQ

LC 

O

PTI

C

AM

10G

IG

50/125μm multimode simplex fibre

optic connector for 900μm tight-buffered fibre installation.

Aqua

1

10

FLCDMCXAQ

LC 

O

PTI

C

AM

10G

IG

50/125μm multimode duplex fibre

optic connector for 900μm tight-buffered fibre installation.

Aqua

1

10

LC 

O

PTI

C

AM

50/125μm Multimode Fibre Optic Connectors

FLCSMC5BL

LC 

O

PTI

C

AM

50/125μm multimode simplex fibre optic

connector for 900μm tight-buffered fibre installation.

Black

1

10

FLCDMC5BL

LC 

O

PTI

C

AM

50/125μm multimode duplex fibre optic

connector for 900μm tight-buffered fibre installation.

Black

1

10

LC 

O

PTI

C

AM

62.5/125μm Multimode Fibre Optic Connectors

FLCSMC6BL

LC 

O

PTI

C

AM

62.5/125μm multimode simplex fibre optic

connector for 900μm tight-buffered fibre installation.

Black

1

10

FLCDMC6BL

LC 

O

PTI

C

AM

62.5/125μm multimode duplex fibre optic

connector for 900μm tight-buffered fibre installation.

Black

1

10

LC

O

PTI

C

AM

Singlemode Fibre Optic Connectors

FLCSSCBU

LC 

O

PTI

C

AM

singlemode simplex fibre optic connector for

900μm tight-buffered fibre installation.

Blue

1

10

FLCDSCBU

LC 

O

PTI

C

AM

singlemode duplex fibre optic connector for

900μm tight-buffered fibre installation.

Blue

1

10

O

PTI

C

AM

1.6/2.0mm Boots 

FXCBT2AQ-X

O

PTI

C

AM

10G

IG

1.6/2.0mm boot.

Aqua

10

100

FMCBT2BL-X

O

PTI

C

AM

multimode 1.6/2.0mm boot.

Black

10

100

FSCBT2BU-X

O

PTI

C

AM

singlemode 1.6/2.0mm boot.

Blue

10

100

O

PTI

C

AM

3.0mm Boots

FXCBT3AQ-X

O

PTI

C

AM

10G

IG

3.0mm boot.

Aqua

10

100

FMCBT3BL-X

O

PTI

C

AM

multimode 3.0mm boot.

Black

10

100

FSCBT3BU-X

O

PTI

C

AM

singlemode 3.0mm boot.

Blue

10

100

LC 

O

PTI

C

AM

Duplex Clip

FLCCLIPBL-L

LC 

O

PTI

C

AM

duplex clip for duplexing two simplex LC

O

PTI

C

AM

multimode or singlemode connectors.

Black

50

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

94

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

FSCMCXAQ

FSCDMC6BL

FSCSCBU

FSCCLIP-L

SC 

O

PTI

C

AM

Fibre Optic Connectors – Pre-Polished

Cam Termination

• TIA/EIA-604 FOCIS-3 compliant connectors
• Exceed TIA/EIA-568-B.3 requirements
• Insertion loss: .40dB typical (multimode and singlemode)
• Return loss: >20dB (multimode), >50dB (singlemode) 
• Quick installation, greater than 50% faster than

conventional epoxy connectors, with high
performance/yield

• Cam termination design allows multiple field

fibre re-terminations 

• Factory pre-polished fibre endface simplifies termination

method over standard field polish connectors

• No consumable materials required; user friendly
• Non-optical disconnect maintains data transmission under

tensile loads for jacketed cable

• Mechanical crimp cable retention consistently provides

higher than industry standard cable retention

• Cam activated fibre and buffer clamp mechanisms provide

superior fibre and buffer retention — less sensitivity to fibre
tensile loading

• No separate clamps, tools or steps are required to secure

both the fibre and the buffer

• Fibre cable type: tight-buffered only
• Fibre cable size: 900μm tight-buffered fibre with included

boot(s); 1.6mm – 2.0mm and 3.0mm jacketed cable with
available 

O

PTI

C

AM

1.6mm/2.0mm and 3.0mm Boot(s) —

10 per package

• Ferrule type: 2.5mm zirconia ceramic (highest durability

for repeated matings)

• Available visual fault locator is integrated into the

termination tool (OCTT) to simplify tooling and termination 

• Use one of the Pre-Polished Termination Kits on

page 106

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

SC 

O

PTI

C

AM

10G

IG

50/125μm Multimode Fibre Optic Connectors

FSCMCXAQ

SC 

O

PTI

C

AM

10G

IG

50/125μm multimode simplex fibre

optic connector for 900μm tight-buffered fibre installation.

Aqua

1

10

FSCDMCXAQ

SC 

O

PTI

C

AM

10G

IG

50/125μm multimode duplex fibre

optic connector for 900μm tight-buffered fibre installation.

Aqua

1

10

SC 

O

PTI

C

AM

50/125μm Multimode Fibre Optic Connectors

FSCMC5BL

SC 

O

PTI

C

AM

50/125μm multimode simplex fibre optic

connector for 900μm tight-buffered fibre installation.

Black

1

10

FSCDMC5BL

SC 

O

PTI

C

AM

50/125μm multimode duplex fibre optic

connector for 900μm tight-buffered fibre installation.

Black

1

10

SC 

O

PTI

C

AM

62.5/125μm Multimode Fibre Optic Connectors

FSCMC6BL

SC 

O

PTI

C

AM

62.5/125μm multimode simplex fibre optic

connector for 900μm tight-buffered fibre installation.

Black

1

10

FSCMPC6BL

SC 

O

PTI

C

AM

polymer 62.5/125μm multimode

simplex fibre optic connector for 900μm tight-buffered
fibre installation.

Black

1

10

FSCDMC6BL

SC 

O

PTI

C

AM

62.5/125μm multimode duplex fibre optic

connector for 900μm tight-buffered fibre installation.

Black

1

10

SC 

O

PTI

C

AM

Singlemode Fibre Optic Connectors

FSCSCBU

SC 

O

PTI

C

AM

singlemode simplex fibre optic connector

for 900μm tight-buffered fibre installation.

Blue

1

10

O

PTI

C

AM

1.6/2.0mm Boots

FXCBT2AQ-X

O

PTI

C

AM

10G

IG

1.6/2.0mm boot.

Aqua

10

100

FMCBT2BL-X

O

PTI

C

AM

multimode 1.6/2.0mm boot.

Black

10

100

FSCBT2BU-X

O

PTI

C

AM

singlemode 1.6/2.0mm boot.

Blue

10

100

O

PTI

C

AM

3.0mm Boots

FXCBT3AQ-X

O

PTI

C

AM

10G

IG

3.0mm boot.

Aqua

10

100

FMCBT3BL-X

O

PTI

C

AM

multimode 3.0mm boot.

Black

10

100

FSCBT3BU-X

O

PTI

C

AM

singlemode 3.0mm boot.

Blue

10

100

SC Duplex Clip 

FSCCLIP-L

SC duplex clip for duplexing two simplex 

PANDUIT

SC

multimode or singlemode connectors.

Black

50

Panduit-Pannet-html.html
background image

95

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

SC Fibre Optic Adapters

• FOCIS-3 TIA/EIA-568-B.3 compliant adapter
• Integrated retention clip automatically adjusts for FOCIS-3

compliant panel thickness variations, creating a snug fit to
reduce rattles; no metal clips to become bent or damaged

• Improved protective cap fully surrounds split 

sleeve opening

• Choice of phosphor bronze or zirconia ceramic split sleeves

to fit specific network requirements; zirconia ceramic split
sleeves are recommended for singlemode performance

• Short flange design for improved modularity and higher

density usage

• Adapters can be used with multimode or singlemode 

connectors and patch cords

• QC number and split sleeve material laser marked on every

adapter assures 100% manufacturer traceability and quick
and easy identification of split sleeve material

• SC Simplex and Duplex Adapters are also available in 

M

INI

-C

OM

modules on page 9, and in patch panels or fibre

adapter panels to provide a complete SC system solution

FADSCEI-L

FASSCZBU-L

Part Number

Part Description

Adapter

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FADSCEI-L

SC duplex fibre optic adapter with phosphor bronze 
split sleeves.

Electric

Ivory

50

100

FADSCZBU-L

SC duplex fibre optic adapter with zirconia ceramic 
split sleeves.

Blue

50

100

FASSCEI-L

SC simplex fibre optic adapter with phosphor bronze 
split sleeves.

Electric

Ivory

50

100

FASSCZBU-L

SC simplex fibre optic adapter with zirconia ceramic 
split sleeves.

Blue

50

100

SC Fibre Optic Connectors - Field Polish

• FOCIS-3 TIA/EIA-568-B.3 compliant connector
• Insertion loss: 0.10dB typical (multimode), 0.15dB 

(singlemode)

• Return loss: >20dB (multimode), >40dB (singlemode)
• Non-optical disconnect maintains data transmission under

tensile loads (jacketed cable only)

• Free floating housing ensures complete latching even 

when inserted by the boot, beneficial in high density 
spacing applications

• Pre-assembled inner housing simplifies assembly

• Each connector includes inner housing assembly, outer

housing, crimp sleeve, one boot for 900m buffered fibre,
one boot for 3mm jacketed cable and one dust cap

• Fibre cable type: tight-buffered recommended
• Fibre cable size: 3.0mm jacketed cable or 900μm 

buffered fibre

• Ferrule type: 2.5mm zirconia ceramic 

(highest durability for repeated matings)

• Field polish termination — 

PANDUIT

recommends 

anaerobic adhesive on page 109

• Use Field Polish Termination Kit (FJKITG) on page 109

To comply with industry standards the connector housing is blue for all singlemode connectors, and electric ivory
for all multimode connectors.

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FSCMBL

SC multimode fibre optic connector — 62.5/125μm or 
50/125μm fibre

Black

1

10

FSCMRD

Red

1

10

FSCSBU

SC singlemode fibre optic connector.

Blue

1

10

FSCM2.0BL

SC multimode simplex fibre optic connector for 1.6mm –
2.0mm jacketed cable or 900μm buffered fibre installation.

Black

1

10

FSCM2.0RD

SC multimode simplex fibre optic connector for 1.6mm –
2.0mm jacketed cable or 900μm buffered fibre installation.

Red

1

10

FSCDM

SC multimode duplex fibre optic connector for 3.0mm
jacketed cable installation.

Red &

Black

1

10

FSCS2.0BU

SC singlemode simplex fibre optic connector for 1.6mm –
2.0mm jacketed cable or 900μm buffered fibre installation.

Blue

1

10

FSCCLIP-L

SC 

10G

IG

Multimode Fibre Optic Adapters

FASSCAQ-L

SC 

10G

IG

simplex multimode fibre optic

adapter with phosphor bronze split sleeve.

Aqua

1

10

FASSCZAQ-L

SC 

10G

IG

simplex multimode fibre optic

adapter with zirconia ceramic split sleeve.

Aqua

1

10

FADSCAQ-L

SC 

10G

IG

duplex multimode fibre optic

adapter with phosphor bronze split sleeves.

Aqua

1

10

FADSCZAQ-L

SC 

10G

IG

duplex multimode fibre optic

adapter with zirconia ceramic split sleeves.

Aqua

1

10

FSCMBL

FSCMRD

FSCSBU

SC APC Singlemode Fibre Optic Adapters

FASSCZAG-L

SC APC simplex singlemode fibre optic adapter
with zirconia ceramic split sleeve.

Green

50

100

FADSCZAG-L

SC APC duplex singlemode fibre optic adapter
with zirconia ceramic split sleeves.

Green

50

100

Panduit-Pannet-html.html
background image

96

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

LC Simplex Fibre Optic Connectors - Field Polish

• FOCIS-10 TIA/EIA-568-B.3 compatible connector
• Non-optical disconnect maintains data transmission under

tensile loads (jacketed cable only)

• Each connector includes connector body/ferrule 

assemblies, crimp sleeve, one boot for 900m buffered fibre,
one boot for 1.6mm or 2.0mm jacketed cable and dust cap

• Fibre cable type: Tight-buffered recommended

• Fibre cable size: 1.6mm  or 2.0mm jacketed cable or

900μm buffered fibre

• Ferrule type: 1.25mm zirconia ceramic 

(highest durability for repeated matings)

• Field polish termination — 

PANDUIT

recommends 

anaerobic adhesive on page 109

• Use LC Field Polish Termination Kit (FLPKIT)

FLCSMEI

FLCSSBU

Part Number

Part Description

C

o

lo

u

r

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FLCSMEI

LC multimode simplex fibre optic connector — 62.5/125μm or
50/125μm fibre.

Electric

Ivory

1

10

FLCSSBU

LC singlemode simplex fibre optic connector.

Blue

1

10

M

INI

-C

OM

SC Fibre Optic Adapter Modules

• FOCIS-3 TIA/EIA-568-B.3 compliant adapter
• Compatible with 

M

INI

-C

OM

products for 

complete modularity

• Improved protective cap fully surrounds split 

sleeve opening

• Can be used with multimode or singlemode connectors and

patch cords

• Choice of phosphor bronze or zirconia ceramic split sleeves

to fit specific network requirements; zirconia ceramic split
sleeves are recommended for singlemode performance

• QC number and split sleeve material laser marked on

every adapter assures 100% traceability and quick and
easy identification of split sleeve material

M

INI

-C

OM

SC Simplex Adapter Modules are commonly

used with 

M

INI

-C

OM

Patch Panels

M

INI

-C

OM

SC Simplex Adapter Modules are commonly

used with 

M

INI

-C

OM

Surface Mount Boxes

• SC Simplex and Duplex Adapters are also available 

separately, and in patch panels or fibre adapter panels to
provide a complete SC system solution

CMDEISC

CMSBUSCZ

‡ For other colours, replace suffix AW (Arctic White) or BU (Blue) with BL (Black), IW (Off White), or 
EI (Electric Ivory).

Part Number

Part Description

No. of

Module
Spaces

Module

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMDEISCAW

Module supplied with one SC duplex fibre optic
adapter with phosphor bronze split sleeves.

2

Arctic
White

1

10

CMDBUSCZBU

Module supplied with one SC duplex fibre optic
adapter with zirconia ceramic split sleeves.

2

Blue

1

10

CMSEISCAW

Module supplied with one SC simplex fibre optic
adapter with phosphor bronze split sleeve.

1

Arctic
White

1

10

CMSBUSCZBU

Module supplied with one SC simplex fibre optic
adapter with zirconia ceramic split sleeve.

1

Blue

1

10

See page 28 in the Modules section for 

M

INI

-C

OM

LC Sr./Jr. Fibre optic

adapter modules 

Panduit-Pannet-html.html
background image

97

LC Duplex Fibre Optic Connectors - Field Polish

• FOCIS-10 TIA/EIA-568-B.3 compatible connector
• Non-optical disconnect maintains data transmission under

tensile loads (jacketed cable only)

• Each duplex connector includes two connector body/ferrule

assemblies, two crimp sleeves, two boots for 1.6mm or 2.0
jacketed cable, two dust caps and one duplexing clip

• Fibre cable type: Tight-buffered recommended

• Fibre cable size: 1.6mm  or 2.0mm jacketed cable
• Ferrule type: 1.25mm zirconia ceramic 

(highest durability for repeated matings)

• Field polish termination — 

PANDUIT

recommends 

anaerobic adhesive on page 109

• Use LC Field Polish Termination Kit (FLPKIT)

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FLCDMEI

LC multimode duplex fibre optic connector — 62.5/125μm or
50/125μm fibre.

Electric

Ivory

1

10

FLCDSBU

LC singlemode duplex fibre optic connector.

Blue

1

10

LC Duplex Connectors for 900μm Buffered Fibre

• Include 900μm boots for installation onto 900μm 

buffered fibre

• Designed for Field Polishing installation

• Require use of LC Field Polish Termination Kit (FLPKIT-W)

FLCDM900EI

Part Number

Part Description

Colour

Std. Pkg.

Qty.

FLCDM900EI

LC multimode duplex fibre optic connector for 900μm
buffered fibre installation

Electric

Ivory

1

FLCDS900BU

LC singlemode duplex fibre optic connector for 900μm
buffered fibre installation.

Blue

1

FLCDMEI

FLCDSBU

FLCDS900BU

FLCCLIP-L

LC duplex clip for duplexing two simplex 

PANDUIT

LC

field polish multimode or singlemode connectors.

White

50

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

98

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

M

INI

-C

OM

LC Sr./Sr. Fibre Optic Adapter Modules

• FOCIS-10 TIA/EIA-568-B.3 compatible adapter
• Mini-duplex adapter design fits into single module space
• Compatible with 

M

INI

-C

OM

products for 

complete modularity

• Sr./Sr. (Senior/Senior) adapter modules have a FOCIS-10

senior adapter interface at each end

• Accepts all FOCIS-10 compatible LC connectors

• Choice of phosphor bronze or zirconia ceramic split sleeves

to fit specific network requirements, zirconia ceramic split
sleeves are required for singlemode performance

M

INI

-C

OM

LC Duplex Adapter Modules are 

commonly used with 

M

INI

-C

OM

Faceplates and 

Surface Mount Boxes

• LC Simplex and Duplex Adapters are also available 

separately, and in patch panels or fibre adapter panels 
to provide a complete LC systems solution

CMDSLC

CMDSLCZ

‡ For other colours replace suffix AW (Arctic White) or BU (Blue) with BL (Black), IW (Off White) or 
EI (Electric Ivory).

Part Number

Part Description

No. of

Module
Spaces

Module

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMDSLCAW

Module supplied with one LC Sr./Sr. mini duplex
multimode fibre optic adapter with phosphor
bronze split sleeves.

1

Arctic
White

1

10

CMDSLCZBU

Module supplied with one LC Sr./Sr. mini duplex
singlemode fibre optic adapter with zirconia
ceramic split sleeves.

1

Blue

1

10

LC Sr./Sr. Fibre Optic Adapters

• TIA/EIA-604 FOCIS-10 compatible adapters
• Exceed TIA/EIA-568-B.3 requirements 
• Mini duplex adapter design fits into simplex SC 

adapter opening

• Sr./Sr. (Senior/Senior) adapters have a FOCIS-10 senior

adapter interface at each end 

• Accepts FOCIS-10 compatible senior LC connectors

• Choice of phosphor bronze or zirconia ceramic split sleeves

to fit specific network requirements; zirconia ceramic split
sleeves are required for singlemode applications

• LC Simplex and Duplex Adapters are also available in

patch panels or fibre adapter panels to provide a complete
LC system solution 

• LC Duplex Adapters are also available in 

M

INI

-C

OM

Modules on page 100

FASSLCZBU-L

FADSLCEI-L

FADSLCAQ-L

Part Number

Part Description

Adapter

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

LC Sr./Sr. Multimode Fibre Optic Adapters

FADSLCEI-L

LC Sr./Sr. SFF duplex multimode fibre optic adapter with
phosphor bronze split sleeves.

Electric

Ivory

50

100

LC Sr./Sr. 

10G

IG

Multimode Fibre Optic Adapters

FASSLCZAQ-L

LC Sr./Sr. 

10G

IG

SFF simplex multimode fibre optic

adapter with zirconia ceramic split sleeve.

Aqua

1

10

FADSLCAQ-L

LC Sr./Sr. 

10G

IG

SFF duplex multimode fibre optic

adapter with phosphor bronze split sleeves.

Aqua

1

10

FADSLCZAQ-L

LC Sr./Sr. 

10G

IG

SFF duplex multimode fibre optic

adapter with zirconia ceramic split sleeves.

Aqua

1

10

LC Sr./Sr. Singlemode Fibre Optic Adapters

FADSLCZBU-L

LC Sr./Sr. SFF duplex singlemode fibre optic adapter with
zirconia ceramic split sleeves.

Blue

50

100

FASSLCZBU-L

LC Sr./Sr. SFF simplex singlemode fibre optic adapter
with zirconia ceramic split sleeve.

Blue

50

100

Panduit-Pannet-html.html
background image

99

*ST is a registered trademark of Lucent Technologies

M

INI

-C

OM

FJ 

O

PTI

-C

RIMP

Keyed Duplex Jack Modules - 

Pre-polished Crimp

• Includes all of the same features as the 

FJ O

PTI

-C

RIMP

Jack Modules (listed on page ) with the added benefit of
mechanical network security

• Insertion loss: 0.3dB typical (62.5/125μm), 0.35dB typical

(50/125μm)

• Return loss: >20dB (multimode)
• Mechanical keyed configurations prevent unintentional

insertion into segregated network ports

• Colour-coded for network identification
• Corresponding FJ Keyed Plugs found on page 102

FJJSMM5CWBL

FJJSMM5CXRD

Replacement Ferrule Assemblies for FJ 

O

PTI

-C

RIMP

Jack Modules

• Eliminates the need to purchase complete FJ 

O

PTI

-C

RIMP

Jack Modules or FJ 

O

PTI

-C

RIMP

Keyed Jack Modules if 

necessary to re-terminate

• Includes ten ferrule assemblies, crimp sleeves and 

dust caps

• Dust caps are colour-coded: clear for 62.5/125μm and

orange for 50/125μm

FJJSMM

FJJSMM5CYOR

FJJSMM5CZYL

Can be clearly identified with labels; For complete labelling solutions and product information, reference the
Labelling and Administration section on page 349-356 and www.panduit.com

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FJJSMM5CWBL

FJ 

O

PTI

-C

RIMP

62.5/125μm keyed (W)

multimode duplex fibre optic jack module
with phosphor bronze split sleeves.

1

Black

1

10

FJJSMM5CXRD

FJ 

O

PTI

-C

RIMP

62.5/125μm keyed (X)

multimode duplex fibre optic jack module
with phosphor bronze split sleeves.

1

Red

1

10

FJJSMM5CYOR

FJ 

O

PTI

-C

RIMP

62.5/125μm keyed (Y)

multimode duplex fibre optic jack module
with phosphor bronze split sleeves.

1

Orange

1

10

FJJSMM5CZYL

FJ 

O

PTI

-C

RIMP

62.5/125μm keyed (Z)

multimode duplex fibre optic jack module
with phosphor bronze split sleeves.

1

Yellow

1

10

FJJSMM50CWBL

FJ 

O

PTI

-C

RIMP

50/125μm keyed (W)

multimode duplex fibre optic jack module
with phosphor bronze split sleeves.

1

Black

1

10

FJJSMM50CXRD

FJ 

O

PTI

-C

RIMP

50/125μm keyed (X)

multimode duplex fibre optic jack module
with phosphor bronze split sleeves.

1

Red

1

10

FJJSMM50CYOR

FJ 

O

PTI

-C

RIMP

50/125μm keyed (Y)

multimode duplex fibre optic jack module
with phosphor bronze split sleeves.

1

Orange

1

10

FJJSMM50CZYL

FJ 

O

PTI

-C

RIMP

50/125μm keyed (Z)

multimode duplex fibre optic jack module
with phosphor bronze split sleeves.

1

Yellow

1

10

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FJJSMMFRL-X

Replacement ferrule assembly, crimp sleeve and clear dust cap for
FJ 

O

PTI

-C

RIMP

62.5/125μm multimode duplex jack module.

10

50

FJJSMM50FRL-X

Replacement ferrule assembly, crimp sleeve and orange dust cap
for FJ 

O

PTI

-C

RIMP

50/125μm multimode duplex jack module.

10

50

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

100

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

M

INI

-C

OM

FJ Duplex Fibre Optic Jack Modules – Field Polish

• FOCIS-6TIA/EIA-568-B.3 compliant connector
• Insertion loss: .1dB typical (multimode), .2dB typical 

(singlemode)

• Return loss: .20dB (multimode), .40dB (singlemode)
• RJ45 small form factor duplex jack module — double the

port density in one module space

• Non-optical disconnect maintains data transmission under

tensile loads

M

INI

-C

OM

module snaps into or out of all 

M

INI

-C

OM

telecommunications room products and work area outlets

• Each duplex jack module includes housing, cover, two 

ferrule assemblies, two crimp sleeves, one boot for 900μm
buffered fibre, one boot for 3mm jacketed cable, and one
dust cap

• Can be clearly identified with labels below
• Fibre cable type: tight-buffered recommended
• Fibre cable size:3.0mm jacketed cable or 900μm 

buffered fibre

• Ferrule type: 2.5mm zirconia ceramic 

(highest durability for repeated matings)

• Corresponding FJ Plugs found on page 102
• Field polish termination — 

PANDUIT

recommends 

anaerobic adhesive on page 109

• Use field Polish Termination Kit (FJKTG) on page 109

FJJGS9C

To comply with industry standards, the housing, cover and boots are blue for singlemode jack modules and
electric ivory for multimode jack modules.
‡For other colours replace suffix EI (Electric Ivory) or BU (Blue) with BL (Black), IW (Off White), or 
AW (Arctic White).  
Can be clearly identified with labels; For complete labelling solutions and product information, reference the
Labelling and Administration section on pages 349-356 and www.panduit.com

FJJGM5C

M

INI

-C

OM

FJ Keyed Duplex Jack Modules – Field Polish

• Includes all of the same features as the FJ Jack Modules

(listed on page 54) with the added benefit of mechanical
network security

• Insertion loss: 0.1dB typical (multimode)

• Return loss: >20dB (multimode)
• Mechanical keyed configurations prevent unintentional

insertion into segregated network ports

• Colour-coded for network identification

FJJGM5CWBL

FJJGM5CXRD 

FJJGM5CYOR

FJJGM5CZYL

Can be clearly identified with labels; For complete labelling solutions and product information, reference the
Labelling and Administration section on pages 349-356 and www.panduit.com

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FJJGM5CEI

FJ multimode duplex fibre optic jack module
with phosphor bronze split sleeves —
62.5/125μm or 50/125μm fibre.

1

Electric

Ivory

1

10

FJJGS9CBU

FJ singlemode duplex fibre optic jack module
with zirconia ceramic split sleeves.

1

Blue

1

10

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FJJGM5CWBL

FJ keyed (W) multimode duplex fibre optic
jack module with phosphor bronze split
sleeves — 62.5/125μm or 50/125μm fibre.

1

Black

1

10

FJJGM5CXRD

FJ keyed (X) multimode duplex fibre optic
jack module with phosphor bronze split
sleeves — 62.5/125μm or 50/125μm fibre.

1

Red

1

10

FJJGM5CYOR

FJ keyed (Y) multimode duplex fibre optic
jack module with phosphor bronze split
sleeves — 62.5/125μm or 50/125μm fibre.

1

Orange

1

10

FJJGM5CZYL

FJ keyed (Z) multimode duplex fibre optic
jack module with phosphor bronze split
sleeves — 62.5/125μm or 50/125μm fibre.

1

Yellow

1

10

Panduit-Pannet-html.html
background image

101

101

M

INI

-C

OM

FJ

O

PTI

-C

RIMP

Duplex Jack Modules – Pre-polished Crimp

• FOCIS-6 TIA/EIA-568-B.3 compliant connector
• Insertion loss: 0.3dB typical (62.5/125μm), 0.35dB typical

(50/125μm)

• Return loss: >20dB
• Pre-polished mechanical crimp termination eliminates 

polishing and adhesive, reducing installation time by 70%
over field polish FJ jack modules

• Non-optical disconnect maintains data transmission under

tensile loads

• Mechanical crimp cable retention consistently provides

higher than industry standard cable retention

FJ O

PTI

-C

RIMP

jack modules and crimp tool allow visual 

verification of optimal continuity during crimp termination
with the FVFLKIT Visual Fault Locator Kit (included in
FJMVKIT Termination Kit)

• RJ-45 small form factor duplex jack module — double the

port density in one module space

M

INI

-C

OM

TM

module snaps into or out of all 

M

INI

-C

OM

TM

closet products and work area outlets

• Each duplex jack module includes housing, cover, two 

ferrule assemblies with pre-polished fibre stubs, two crimp
sleeves, one boot for 900m buffered fibre, one boot for
3mm jacketed cable, and one dust cap

• Can be clearly identified with labels shown below
• Fibre cable type: tight-buffered only
• Fibre cable size: 3.0mm jacketed cable or 900μm 

tight-buffered fibre

• Ferrule type: 2.5mm zirconia ceramic 

(highest durability for repeated matings)

• Corresponding FJ Plugs found on page 102
• Use Opti-Crimp Termination Kit (FJMVKIT) on page 107

FJJSMM

‡ For other colours, replace suffix AW (Arctic White) with BL (Black), BU (Blue), IW (Off White) or 
EI (Electric Ivory).

Component Labels for 

M

INI

-C

OM

TM

FJ 

O

PTI

-C

RIMP

Duplex Jack

Modules 

Pre-polished Crimp

For complete labelling solutions and product information, reference the Labelling and Administration section on
pages 349-356 and www.panduit.com

Suggested Label Solutions for TIA/EIA 606-A Compliance

Jack Module 
Part Number

Laser/Ink Jet Desktop Printer Label

P

ANTHER

LS8 

Hand-Held Thermal Printer

All 

M

INI

-C

OM

TM

Jack Modules

C138X019FJJ

C138X019FJC

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FJJSMM5CAW

FJ Opti-Crimp 62.5/125μm multimode
duplex fibre optic jack module with
phosphor bronze split sleeves.

1

Arctic
White

1

10

FJJSMM50CAW

FJ Opti-Crimp 50/125μm multimode duplex
fibre optic jack module with phosphor
bronze split sleeves.

1

Arctic
White

1

10

Replacement Ferrule Assemblies for FJ Field Polish Jack Modules

• Eliminates the need to purchase complete FJ Field Polish

Jack Modules or FJ Field Polish Keyed Jack Modules if
necessary to re-terminate

• Includes ten ferrule assemblies, crimp sleeves and 

dust caps

FJJ

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FJJ9FRL-X

Replacement ferrule assembly, crimp sleeve and dust cap for FJ field
polish singlemode duplex jack module

10

50

FJJFRL-X

Replacement ferrule assembly, crimp sleeve and dust cap for FJ field
polish multimode duplex jack module — 62.5/125μm or 50/125μm fibre.

10

50

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

102

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

FJ Duplex Fibre Optic Plugs – Field Polish

• FOCIS-6 TIA/EIA-568-B.3 compliant connector
• Insertion loss: .1dB typical (multimode), .2dB typical 

(singlemode)

• Return loss: >20dB (multimode), >40dB (singlemode)
• RJ45 small form factor duplex plug
• Non-optical disconnect maintains data transmission under

tensile loads

• Each duplex plug includes housing, insert, two ferrule

assemblies, two crimp sleeves, one boot for 3mm jacketed
cable, and two dust caps

• Fibre cable type: tight-buffered recommended
• Fibre cable size: 3.0mm jacketed cable
• Ferrule type: 2.5mm zirconia ceramic 

(highest durabilty for repeated matings)

• Corresponding FJ 

O

PTI

-

CRIMP

Jack Modules found 

on page 99  and FJ Field Polish Jack Modules found 
on page 109

• Field polish termination — 

PANDUIT

recommends an

anaerobic adhesive on page 109

• Use Field Polish Termination Kit (FJKITG) on page 109

FJEPGS9CBU

FJEPGM5CEI

FJGCCEI

FJ Keyed Duplex Fibre Optic Plugs – Field Polish

• Includes all of the same features as the FJ Plugs 

(listed above) with the added benefit of mechanical 
network security

• Insertion loss: 0.1dB typical (multimode)
• Return loss: >20dB (multimode)
• Mechanical keyed configurations prevent unintentional

insertion into segregated network ports

• Colour-coded for network identification
• Universal keyed plug available
• Corresponding FJ 

O

PTI

-C

RIMP

Keyed Jack Modules

found on page XX and FJ Field Polish Keyed Jack
Modules found on page 109

FJEPGM5CWBL

FJEPGM5CXRD

FJEPGM5CYOR

To comply with industry standards, the housing, insert and boot are blue for singlemode plugs and electric ivory
for multimode plugs.

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FJEPGM5CAW

FJ multimode duplex fibre optic plug — 62.5/125μm or
50/125μm fibre.

Arctic
White

1

10

FJEPGS9CBU

FJ singlemode duplex fibre optic plug.

Blue

1

10

FJGCCEI

Adapter to mate two FJ Duplex Fibre Optic Multimode or
Singlemode Plugs.  Used for the calibration of test cables
and equipment and for FJ plug-to-plug cross connects.
Includes two dust caps.  (Not for use in 

M

INI

-C

OM

Surface Mount Boxes).

Electric

Ivory

1

10

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FJEPGM5CWBL

FJ universal keyed (W) multimode duplex fibre optic plug
— 62.5/125μm or 50/125μm fibre.

Black

1

10

FJEPGM5CXRD

FJ universal keyed (X) multimode duplex fibre optic plug
— 62.5/125μm or 50/125μm fibre.

Red

1

10

FJEPGM5CYOR

FJ universal keyed (Y) multimode duplex fibre optic plug
— 62.5/125μm or 50/125μm fibre.

Orange

1

10

FJEPGM5CZYL

FJ universal keyed (Z) multimode duplex fibre optic plug
— 62.5/125μm or 50/125μm fibre.

Yellow

1

10

FJEPGM5CQWH

FJ universal keyed (Q) multimode duplex fibre optic plug
for universal use for testing purposes — 62.5/125μm or
50/125μm fibre.

White

1

10

FJEPGM2.0CEI

FJ

multimode duplex fibre optic plug for 1.6mm –

2.0mm jacketed cable installation.

Electric

Ivory

1

10

FJEPGS2.0CBU

FJ

singlemode duplex fibre optic plug for 1.6mm –

2.0mm jacketed cable installation.

Blue

1

10

Panduit-Pannet-html.html
background image

103

Replacement Ferrule Assemblies for FJ Field Polish Plugs

• Eliminates the need to purchase complete FJ Field Polish

Plugs or FJ Field Polish Keyed Plugs if necessary to 
re-terminate

• Includes ten ferrule assemblies, crimp sleeves and 

dust caps

• Ferrule housing moulded in blue for singlemode and 

electric ivory for multimode per industry standard

FJEPFRL-X

FJEP9FRL-X

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FJJ9FRL-X

Replacement ferrule assembly, crimp sleeve and dust cap for FJ field
polish singlemode duplex jack module

10

50

FJJFRL-X

Replacement ferrule assembly, crimp sleeve and dust cap for FJ field
polish multimode duplex jack module — 62.5/125μm or 50/125μm fibre.

10

50

LC & SC Duplex Clips Components

• LC and SC Duplex clips allow simplex connectors to be

coupled into a duplex solution

• One piece duplex clips have integrated polarity markers to

allow quick cable identification and polarity changes

• One pack of LC Duplex clips can duplex 100 Simplex LC

connectors

• One pack of SC Duplex clips can duplex 100 Simplex SC

connectors

FLCCLIP-L

FSCCLIP-L

Part Number

Part Description

Std.

Pkg.

Qty.

Colour

FLCCLIP-L

LC duplex clip for duplexing two simplex 

PANDUIT

LC multimode

or singlemode connectors

50

White

FSCCLIP-L

SC duplex clip for duplexing two simplex 

PANDUIT SC multimode

or singlemode connectors

50

Black

FJ – SC Connectors for termination on 1.6mm Fibre Cable

• Include attached crimp sleeve and heat shrink tubing for

bundling up the diameter of the 1.6mm -2.0mm jacketed
cable to a 3mm diameter

• Additional tools required for termination onto 1.6mm –

2.0mm jacketed cable only:

• FLPT crimp tool crimps smaller diameter crimp sleeve onto

1.6mm - 2.0mm cable

• FHSCT-W (230VAC/50Hz) or FHSCT (110VAC/60Hz) Heat

Shrink Curing Tool

• The above tools are included in the FLPKIT-W

(Termination Kit for LC Connectors)

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FSCM2.0BL

MM (62.5/125 micron or 50/125 micron w/black boots

1

10

FSCM2.0RD

MM (62.5/125 micron or 50/125 micron w/red boots

1

10

FSCS2.0BU

SM (9/125 micron)

1

10

FJJGM2.0CEI

MM (62.5/125 micron or 50/125 micron)

1

10

FJJGS2.0CBU

SM (9/125 micron)

1

10

FJEPGM2.0CEI

MM (62.5/125 micron or 50/125 micron) 

1

10

FJEPGS2.0CBU

SM (9/125 micron)

1

10

FSCMM2.0BL

62.5/125 micron w/black boots 

1

10

FSCMM2.0RD

62.5/125 micron w/red boots 

1

10

FSCMM502.0RD

50/125 micron w/red boots 

1

10

FSCMM502.0BL

50/125 micron w/black boots 

1

10

FJEPFRL-X

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

104

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

M

INI

-C

OM

LC Sr./Jr. Fibre Optic Adapter Modules

• FOCIS-10 TIA/EIA-568-B.3 compatible adapter
• Mini-duplex adapter design fits into single module space
• Compatible with 

M

INI

-C

OM

products for 

complete modularity

• Sr./Jr. (Senior/Junior) adapter modules have a FOCIS-10

senior adapter interface at the front and a FOCIS-10 junior
adapter interface at the back

• Both ends accept all FOCIS-10 compatible LC connectors
• Junior end also accepts fixed ferrule LC connectors

CMDJLC

CMDJLCZ

‡ For other colours replace suffix AW (Arctic White) or BU (Blue) with BL (Black), IW (Off White), or 
EI (Electric Ivory).

M

INI

-C

OM

MT-RJ Fibre Optic Adapter Modules

• FOCIS-12 TIA/EIA-568-B.3 compliant adapter
• Compatible with 

M

INI

-C

OM

products for 

complete modularity

• Can be used with multimode connectors and patch cords

M

INI

-C

OM

MT-RJ Duplex Adapter Modules are 

commonly used with 

M

INI

-C

OM

Faceplates and 

Surface Mount Boxes

CMMJ

‡ For other colours replace suffix EI (Electric Ivory) with BL (Black), BU (Blue), IW (Off White), or WH (White).

Part Number

Part Description

No. of

Module
Spaces

Module

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMDJLCAW

Module supplied with one LC Sr./Jr. mini duplex
multimode fibre optic adapter with phosphor
bronze split sleeves.

1

Arctic
White

1

10

CMDJLCZBU

Module supplied with one LC Sr./Jr. mini duplex
singlemode fibre optic adapter with zirconia
ceramic split sleeves.

1

Blue

1

10

Part Number

Part Description

No. of

Module
Spaces

Module

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMMJEI

MT-RJ multimode duplex fibre optic 
adapter module.

1

Electric

Ivory

1

10

250 Micron Fibre Build-Up Tube Kit

• Includes 100 build-up tubes and supplemental instructions

for terminating 

PANDUIT

Field Polish or 

O

PTI

-C

RIMP

Fibre Optic Connectors onto 250μm coated fibre

• Used with 900μm boots included with connectors and the

current fibre optic termination kit

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

F250BT-C

250 micron fibre build-up tube kit; includes 100 build-up tubes and
supplemental installation instructions.

100

Panduit-Pannet-html.html
background image

105

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

M

INI

-C

OM

FC Fibre Optic Adapter Modules

• FOCIS-4 TIA/EIA-568-B.3 compliant adapter
• Compatible with 

M

INI

-C

OM

products for 

complete modularity

• Can be used with multimode or singlemode connectors and

patch cords

• Choice of phosphor bronze or zirconia ceramic split sleeves

to fit specific network requirements; zirconia ceramic split
sleeves are required for singlemode performance

M

INI

-C

OM

FC Simplex Adapter Modules are commonly

used with 

M

INI

-C

OM

Patch Panels

• FC Simplex Adapters are also available in patch panels

and fibre adapter panels to provide a complete FC system
solution.

CMFC

‡ For other colours replace suffix EI (Electric Ivory) or BU (Blue) with BL (Black), IW (Off White), or WH (White).

M

INI

-C

OM

Blank Module

• Seals off openings in outlet to prevent tampering

• Compatible with 

M

INI

-C

OM

modular patch panels, 

faceplates and surface mount boxes

‡ For other colours replace suffix AW (Arctic White) with EI (Electric Ivory), WH (White), IG (International Grey) or
BL (Black).

Part Number

Part Description

No. of

Module
Spaces

Module

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMFCEI

Module supplied with one FC multimode fibre
optic adapter with phosphor bronze split sleeve.

1

Electric

Ivory

1

10

CMFCZBU

Module supplied with one FC singlemode fibre
optic adapter with zirconia ceramic split sleeve.

1

Blue

1

10

Part Number

Part Description

No. of

Module
Spaces

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMBAW-X

One position, reserves space for future use.

1

Arctic
White

10

50

Panduit-Pannet-html.html
background image

106

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

FPPKIT

Components for Pre-Polished Fibre Optic Termination Kits

OCTT

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Stripping Tools (included in FPPKIT and FSTLSKIT)

CST115

Fibre cable jacket stripper.

1

FALC

Alcohol bottle. (contents not included)

1

10

FBFSP

Fibre buffer stripper.

1

10

FSCDVR

Screwdriver.

1

50

FGLS

Safety glasses.

1

10

FTWZR

Tweezers.

1

10

FWBTL

Alcohol bottle. (contents not included)

1

10

FKS

Fibre Kevlar shears.

1

10

FWRKMAT

Fibre safe workmat.

1

10

Pre-Polished Termination Tools (included in FPPKIT and FPPTTKIT)

FCRP5

Crimp tool (hex sizes: .048” = 1.21mm, .100” = 2.5mm, .128” = 3.25mm,
.151” = 3.8mm, .190” = 4.83mm)

1

FJQCVR

Fibre cleaver tool.

1

10

OCTT

O

PTI

C

AM

termination tool; includes batteries, pouch and 2 saddles for each

available 

O

PTI

C

AM

Connector.

1

FVFLPC-2.5SM

Patch cord for all 

O

PTI

C

AM

2.5mm ferrule connectors.

1

10

FVFLPC-1.25SM

Patch cord for all 

O

PTI

C

AM

1.25mm ferrule connectors.

1

10

FVFLPC

Patch cord for all 

O

PTI

C

AM

Connectors (1 meter long).

1

10

Pre-Polished Consumables (included in FPPKIT and FPPRKIT)

FWP-C

Cloth wipes.

100

1000

FSWB-C

Cleaning swabs.

100

1000

FST

Safety stickers for fibre scraps.

1

10

PFX-0

Permanent marking pen, fine tip, black ink.

12

144

Replacement Parts

FJQCVRB

Replacement blade for FJQCVR.

1

10

CD-FCRP5

Die set for FCRP5 tool.

1

Pre-Polished Fibre Optic Termination Kits 

O

PTI

C

AM

and

O

PTI

-C

RIMP

Connectors

• For 

PANDUIT

O

PTI

C

AM

and 

O

PTI

-C

RIMP

Pre-Polished

Connector termination 

• No adhesive or electricity required for termination
• Visual fault locator integrated into 

O

PTI

C

AM

Termination

Tool (OCTT) to simplify tooling and termination

O

PTI

C

AM

Termination Tool (OCTT) can be used for visual

verification of optimal continuity between the field fibre and
the pre-polished fibre stub during 

O

PTI

-C

RIMP

termination

with longer patch cord (FVFLPC); FCRP5 tool must be
used for mechanical crimp termination

• Modular kits are available if other or previous termination

kits or tools are already available

Part Number

Part Description

Std.

Pkg.

Qty.

Pre-Polished Termination Kit 

Terminates 

O

PTI

C

AM

and 

O

PTI

-C

RIMP

Connectors

FPPKIT

Tools and consumables necessary for termination of all 

PANDUIT pre-polished

connectors —

O

PTI

C

AM

and 

O

PTI

-C

RIMP

connectors.

1

Pre-Polished Conversion Kit 

Converts 

O

PTI

-C

RIMP

Termination Kit for

O

PTI

C

AM

Termination

FPPKIT-CV

Converts existing FJMVKIT or FJMKIT to FPPKIT; includes tools required for
termination of 

PANDUIT O

PTI

C

AM

Pre-Polished Connectors, in addition to those

included in the FJMVKIT or FJMKIT — OCTT Tool, FVFLPC-2.5SM and
FVFLPC-1.25SM Patch Cords.

1

Stripping Tools Kit

FSTLSKIT

Basic stripping tools kit; stripping tools that are included in all 

PANDUIT fibre optic

termination kits — FPPKIT, FJMVKIT, FLPKIT and FJKITG.

1

Pre-Polished Termination Tools Kit

FPPTTKIT

Tools required for termination of all 

PANDUIT O

PTI

C

AM

and 

O

PTI

-C

RIMP

Pre-Polished Connectors.

1

Pre-Polished Consumables Refurbishment Kit

FPPRKIT

Pre-polished consumables kit; includes the same quantities that are included in FPPKIT.

1

Refer to component table below for for items included in kits.  

Panduit-Pannet-html.html
background image

107

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

O

PTI

-C

RIMP

Fibre Optic Termination Kit – Pre-polished Crimp

• For 

PANDUIT

pre-polished crimp connector termination 

• No adhesive or electricity required for termination
• Includes FVFLKIT Visual Fault Locator Kit that provides

visual verification of optimal continuity between the field
fibre and the pre-polished fibre stub during 
crimp termination

• Includes non-consumable and consumable components
• Also includes stripping templates for 

PANDUIT

O

PTI

-C

RIMP

connectors and FJ 

O

PTI

-C

RIMP

duplex jack modules

FJMVKIT

Components for 

O

PTI

-C

RIMP

Fibre Optic Termination Kit (FJMVKIT)

FVFLKIT

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Non-Consumables

CST115

Plier nose wire stripper. 

1

FALC

Alcohol bottle (contents not included)

1

10

FBFSP

Fibre buffer stripper

1

10

FGLS

Safety glasses

1

10

FJQCVR

Fibre cleaver tool

1

10

FKC

Fibre cable strength member scissors

1

10

FSCDVR

Screwdriver

1

50

FCRP5

Universal crimp tool

1

FVFLKIT

Visual fault locator kit (includes visual fault locator, belt holster, patch
cord, case, batteries and instructions)

1

1

Consumables

FST

Safety stickers for fibre scraps

1

10

FWP-C

Cloth wipes

100 1000

PFX-0

Permanent marking pen, fine tip.

12

144

Replacement Parts

FJQCVRB

Replacement blade for FJQCVR

1

10

CD-FCRP5

FCRP5 die set

1

FVFL

Visual fault locator (includes batteries and instructions)

1

FVFLPC

Patch cord for FVFL visual fault locator (1 metre long)

1

10

Part Number

Part Description

Std.

Pkg.

Qty.

FJMVKIT

Includes all tools and consumables necessary for termination of SC, ST and
FJ Opti-Crimp multimode connectors and jack modules (also includes
FVFLKIT Visual Fault Locator Kit).

1

Additional Components Required for Terminating SC 

O

PTI

-C

RIMP

Connectors

onto 1.6mm – 2.0mm Jacketed Cable (Select only one Heat Shrink Curing Tool)

FLPT

Crimp tool required for 1.6mm/2.0mm jacketed cable termination.

1

FHSCT

Heat shrink curing tool (110VAC, 60Hz) required for 1.6mm/2.0mm
jacketed cable termination.

1

FHSCT-W

Heat shrink curing tool (230VAC, 50Hz) required for 1.6mm/2.0mm
jacketed cable termination.

1

Panduit-Pannet-html.html
background image

108

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

LC Field Polish Fibre Optic Termination Kits

• For

PANDUIT

LC Connector (1.25mm ferrule) field

polish termination 

• Fast acting adhesive

• Kit provides consumables for terminating up to 100

PANDUIT

LC Connectors

• Also includes stripping template for 

PANDUIT

LC

Connectors (field polish termination)

Components for LC Field Polish Fibre Optic
Termination Kit (FLPKIT)

Part Number

Part Description

Std.

Pkg.

Qty.

LC Field Polish Termination Kits 

FLPKIT

Tools and consumables necessary for termination of LC 1.25mm ferrule
field polish multimode and singlemode connectors; includes FHSCT Heat
Shrink Curing Tool – 110VAC, 60Hz.

1

FLPKIT-W

Tools and consumables necessary for termination of LC 1.25mm ferrule
field polish multimode and singlemode connectors; includes FHSCT-W
Heat Shrink Curing Tool – 230VAC, 50Hz.

1

Refurbishment Kit for FLPKIT and FLPKIT-W

FLPKIT-RFB

Consumables refurbishment kit; includes all of the same consumable
items as the FLPKIT and FLPKIT-W LC Field Polish Termination Kits.

1

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Tools

CST115

Fibre cable jacket stripper.

1

FALC

Alcohol bottle. (contents not included)

1

10

FBFSP

Fibre buffer stripper.

1

10

FBFSPM

Miller fibre buffer stripper.

1

10

FLPT

Crimp tool required for 1.6mm/2.0mm jacketed cable termination.

1

FHSCT

Heat shrink curing tool (110VAC, 60Hz) required for
1.6mm/2.0mm jacketed cable termination.

1

FKS

Fibre Kevlar shears.

1

10

FSCRIBE

Carbide scribe.

1

10

FSCRBLD

Replacement blade for carbide scribe.

1

10

FGLS

Safety glasses.

1

10

FLCPAD

Polishing pad and plate (85 durometer).

1

10

FLCPK

LC polishing puck (1.25mm ferrule).

1

FSCDVR

Screwdriver.

1

50

FSCOPE

Fibre inspection microscope (200X).

1

FLCASCP

1.25mm adapter for FSCOPE.

1

FTWZR

Tweezers.

1

10

FWBTL

Water bottle. (contents not included)

1

10

FPWIRE

Piano wire.

1

10

FWRKMAT

Fibre safe workmat.

1

10

Consumables

FJPMR

Primer (50ml).

1

10

FJPXY

Anaerobic adhesive (10ml).

1

10

FPP5-L

5μm polishing paper (AL2O3).

50

250

FPF1-V

Polishing film - 1μm diamond.

5

50

FLCFPLF-X

0.05μm lapping film.

10

FSWB-C

Cleaning swabs.

100

1000

FST

Safety stickers for fibre scraps.

1

10

FSYR-X

Syringes with needle tips.

10

50

FWP-C

Cloth wipes.

100

1000

PFX-0

Permanent marking pen, fine tip, black ink.

12

144

FLPKIT

Panduit-Pannet-html.html
background image

109

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Field Polish Fibre Optic Termination Kit

PANDUIT

field polish connector termination

• Fast acting adhesive; no electricity required for termination
• Kit provides consumables for terminating up to 100 field

polish connectors

• Includes non-consumable and consumable components
• Also includes stripping templates for 

PANDUIT

field polish

connectors and FJ Duplex Jack Modules and Plugs

FJKITG

Components for Field Polish Fibre Optic Termination Kit (FJKITG)

^Not included in FJKITG or FJKITG-RFB.

Part Number

Part Description

Std.

Pkg.

Qty.

Field Polish Termination Kit

FJKITG

Includes tools and consumables necessary for termination of 2.5mm ferrule
field polish multimode connectors (FJ Duplex Jack Modules and Plugs, ST*,
SC).  Also terminates 2.5mm ferrule singlemode connectors with singlemode
polishing cloth, film and slurry (purchased separately).

1

Refurbishment Kit for FJKITG

FJKITG-RFB

Consumables refurbishment kit.  Includes all of the same consumable items
in the same quantites as FJKITG.

1

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Non-Consumables

CST115

Plier nose wire stripper. 

1

FALC

Alcohol bottle. (contents not included)

1

10

FBFSP

Fibre buffer stripper

1

10

FBFSPM^

Miller fibre cable buffer stripper

1

10

FCRP5

Universal crimp tool

1

FCVR

Fibre cleaver

1

10

FGLS

Safety glasses

1

10

FJPKGU

Universal polishing puck

1

10

FKC

Fibre cable strength member scissors

1

10

FPAD

Fibre polishing pad

1

10

FSCDVR

Screwdriver

1

50

FSCP

Fibre inspection microscope

1

FTWZR

Tweezers

1

10

FWBTL

Water bottle

1

10

Consumables

FJPMR

Primer (50ml)

1

10

FJPXY

Anaerobic adhesive (10ml)

1

10

FPP1-L

1m polishing paper (AL 2 0 3)

50

250

FPP5-L

5m polishing paper (AL 2 0 3)

50

250

FSWB-C

Cleaning swabs

100 1000

FST

Safety stickers for fibre scraps

1

10

FSYR-X

Syringes with needle tips

10

50

FWP-C

Cloth wipes

100 1000

PFX-0

Permanent marking pen, fine tip.

12

144

Additional Components for Singlemode SC and ST* Connectors and Singlemode
FJ Jack Modules and Plugs

FPCL-Q^

Singlemode polishing cloth (not included in FJKITG)

25

250

FPF1-V^

Singlemode polishing film - 1m diamond (not included in FJKITG)

5

50

FPSL^

Singlemode polishing slurry (not included in FJKITG)

1

10

Panduit-Pannet-html.html
background image

110

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

O

PTICOM

Rack Mount Splice Enclosures

• Can be mounted to any standard EIA 482.6mm or

584.2mm rack or cabinet

• Include fibre optic cable routing accessory kit and label

• Top, bottom and side cable entry

• Accept 

O

PTICOM

Fibre Adapter Panels

FRME1

FRME2

FRME3

FRME4

FRME48AIBL

FRME48AINSBL

O

PTICOM

Fibre Optic Rack Mount Splice Enclosures

• Can be mounted to any standard EIA 19” or 23” rack 

or cabinet

• Built-in slack manager for easy storage of slack fibre

• Accept FST6 splice tray

• Include fibre optic cable routing accessory kit and label

FRME72SBL

FRME144SBL

^One rack space = 44.45mm
Optional locks available for Rack Mount Enclosures.
Fibre optic cable routing accessory kits contain various cable management components such as 

PANDUIT

cable

ties, strain relief, moulded grommet(s), saddle clips/spools and fibre caution labels.
All product colour is black.

^One rack space = 44.45mm
Optional locks available.
Fibre optic cable routing accessory kits contain various cable management components such as 

PANDUIT

cable

ties, strain relief, moulded grommet(s), saddle clips/spools and fibre caution labels.
All product colour is black.

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Opticom Fibre Optic Rack Mount Enclosures

FRME1

Accepts up to (3) FAP or FMP adapter panels. Support up to
(24) ST*, (36) SC or (36) FJ fibre optic terminations. 
Includes a slide out / tilt down drawer for easy access. 
Dimensions 44.2mm H x 292.1mm D x 482.6mm W

1

1

FRME2

Accepts up to (6) FAP or FMP adapter panels. Support up to
(48) ST*, (72) SC or (72) FJ fibre optic terminations. 
Includes a slide out / tilt down drawer for easy access. 
Dimensions 87.6mm H x 295.9mm D x 482.6mm W

2

1

FRME3

Accepts up to (9) FAP or FMP adapter panels. Support up to
(72) ST*, (108) SC or (108) FJ fibre optic terminations.
Dimensions 132.8mm H x 295.1mm D x 482.6mm W

3

1

FRME4

Accepts up to (12) FAP or FMP adapter panels, (1) splice
tray holder (FST24H3) and (3) splice trays (FST24). Support
up to (96) ST*, (144) SC or (144) FJ fibre optic terminations. 
Dimensions 175.3mm H x 295.9mm D x 482.6mm W

4

1

Opticom Rack and Under-Floor Mount Enclosures

FRME48AIBL

Includes (24) shuttered angled inserts. Can be hung from the
side of wire cable tray.
Dimensions 130mm H x 146mm D x 482.6mm W

3

1

FRME48AINSBL

Includes (24) angled inserts. Can be hung from the side of
wire cable tray.
Dimensions 130mm H x 147mm D x 482.6mm W

3

1

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

FRME72SBL

Opticom Fibre Optic Splice Enclosure. Holds up to (6) splice
trays (FST6).
Includes a slide out drawer for easy access. 
Dimensions 87.6mm H x 298.9mm D x 482.6mm W.

2

1

FRME144SBL

Opticom Fibre Optic Splice Enclosure. Holds up to (12)
splice trays (FST6).
Dimensions 173.5mm H x 298.9mm D x 482.6mm W.

4

1

Panduit-Pannet-html.html
background image

111

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

O

PTICOM

PreLoaded Trays

• Factory installed adapters

• Removable patch panel allows rear access from front 

of unit

• Can be mounted flush to any standard EIA 19” or 23” rack

or cabinet

• Mount flush or 50.8mm recessed on 19” rack 

or cabinet

• Include fibre optic cable routing accessory kit

O

PTICOM

Trays

• Removable rear tray cover provides easy access to splices

and cable storage

• Side and rear cable entry

• Can be mounted to standard EIA 19” rack or cabinet

• Include fibre optic cable routing accessory kit

^One rack space = 44.45mm
Fibre Optic Cable Routing Accessory Kit contains various fibre optic cable management components such as

PANDUIT

cable ties, adhesive backed mounts, innerduct pieces and grommet edging.

All product colour is black.

FT1W24ST

FMT2

All product colour is black.

Part Number

Part Description

No. of Rack

Spaces

Std.

Pkg.

Qty.

FT1W12DSC

Includes (12) port blue duplex SC adapters with phosphor
bronze split sleeves. 
Dimensions 44.5mm H x 203.4mm D x 482.6mm W

1

1

FT1W12ST

Includes (12) port ST* adapters with phosphor bronze split
sleeves. Dimensions 44.5mm H x 203.4mm D x 482.6mm W

1

1

FT1W24ST

Includes (24) port ST* adapters with phosphor bronze split
sleeves. Dimensions 44.5mm H x 203.4mm D x 482.6mm W

1

1

FT124MC

Will accept up to (24) port 

M

INI

-C

OM

modules. No adapters

included. Dimensions 44.5m H x 203.4mm D x 482.9mm W

1

1

Part Number

Part Description

No. of Rack

Spaces^

Std.

Pkg.

Qty.

FMT1

Mounts behind modular patch panels, such as CFAPPBL and
accepts up to (1) splice tray holder (FSTHE) and (2) splice 
trays (FST6).
Dimensions 44.9mm H x 283.4mm D x 482.6mm W

1

1

FMT2

Mounts behind module patch panels such as CFAPPBL2 and
accepts up to (1) splice tray holder (FSTHE) and (4) splice 
trays (FST6)
Dimensions 88.29mm H x 283.36mm D x 482.60mm W

2

1

Panduit-Pannet-html.html
background image

112

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

O

PTICOM

Drawers

• Drawer slides out for easy front access
• Accept 

O

PTICOM

Fibre Adapter Panels

• Rear tray capacity for splice tray installation
• Can be mounted to EIA 19” rack or cabinet
• Removable rear tray provides easy access to splices and

cable storage

• Include fibre optic routing accessory kit
• Patented front bend radius control clips
• Side and rear cable entry

^One rack space = 44.45mm
Fibre optic cable routing accessory kits contain various cable management components such as 

PANDUIT

cable

ties, strain relief, moulded grommet(s), saddle clips / spools and fibre caution labels.
All product colour is black.

FMD2

Fibre Adapter Patch Panels

• Can be mounted to any EIA 19” rack or cabinet
• Mount to Opticom Trays

• Accept Opticom Fibre Adapter Panels.

All product colour is black.

CFAPPBL1

CFAPPBL2

Part Number

Part Description

No. of Rack

Spaces

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CFAPPBL1

Accepts up to (4) FAP or FMP Adapter Panels.
Dimensions 1.72H x 19W (33mm x 482mm)

1

1

10

CFAPPBL2

Accepts up to (8) FAP or FMP Adapter Panels.
Dimensions 3.47H x 19W (88mm x 482mm)

2

1

10

Part Number

Part Description

No. of Rack

Spaces^

Std.

Pkg.

Qty.

FMD1

Slide out drawer accepts up to (4) FAP or FMP Adapter Panels,
(1) splice tray holder (FSTHE) and (2) splice trays (FST6).
Supports up to (32) ST, (48) SC or (48) FJ fibre optic
terminations.
Dimensions 44.45mm H x 504.19mm W x 389.38mm D.

1

1

FMD2

Slide out drawer accepts up to (8) FAP or FMP Adapter Panels,
(1) splice tray holder (FSTHE) and (4) splice trays (FST6).
Supports up to (64) ST, (96) SC or (96) FJ fibre optic
terminations.
Dimensions 88.30mm H x 504.19mm W x 391.16mm D.

2

1

Panduit-Pannet-html.html
background image

113

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

O

PTICOM

Pre-Terminated Trays and Drawers

• Simplify installation process
• Factory terminated with 2 metres 900μm jacketed cable

(62.5/125μm)

• Factory assembled and tested connectors

• Include splice trays that accommodate mechanical or

fusion splices

• Can be mounted to standard EIA 19” rack or cabinet

FMT24STMP

FMD24STMP

Part Number

Part Description

No. of Rack

Spaces^

Std.

Pkg.

Qty.

Pre-Terminated Trays

FMT24STMP

Assembled with (24) ST Pigtails, (1) CFAPPBL1, (4)
FAP6WST, (1) splice tray holder (FSTHE) and (2) splice
trays (FST6).
Dimensions 44.5mm H x 482.6mm W x 284.0mm D

1

1

FMT24SCMP

Assembled with (24) SC Pigtails, (1) CFAPPBL1, (4)
FAP3WDSC, (1) splice tray holder (FSTHE) and (2) splice
trays (FST6).
Dimensions 44.5mm H x 482.6mm W x 284.0mm D

1

1

FMT24FJMP

Assembled with (12) FJ duplex Pigtails, (1) CFAPPBL1, (2)
FMP6, (2) FAPB, (1) splice tray holder (FSTHE) and (2)
splice trays (FST6).
Dimensions 44.5mm H x 482.6mm W x 284.0mm D

1

1

FMT48STMP

Assembled with (48) ST Pigtails, (1) CFAPPBL2, (8)
FAP6WST, (1) splice tray holder (FSTHE) and (4) splice
trays (FST6).
Dimensions 88.9mm H x 482.6mm W x 284.0mm D

2

1

FMT48SCMP

Assembled with (48) SC Pigtails, (1) CFAPPBL2, (4)
FAP3BUDSC, (1) splice tray holder (FSTHE) and (4) splice
trays (FST6).
Dimensions 88.9mm H x 482.6mm W x 284.0mm D

2

1

FMT48FJMP

Assembled with (24) duplex FJ Pigtails, (1) CFAPPBL2, (4)
FMP6, (4) FAPB, (1) splice tray holder (FSTHE) and (4)
splice trays (FST6).
Dimensions 88.9mm H x 482.6mm W x 284.0mm D

2

1

Pre-Terminated Drawers

FMD24STMP

Assembled with (24) ST* Pigtails,(4) FAP6WST, (1) FSTHE
and (2) FST6 splice trays.
Dimensions 44.5mm H x 482.6mm W x 389.5mm D

1

1

FMD24FJMP

Assembled with (12) duplex FJ

TM

Pigtails, (2) FMP6, (2)

FAPB, (1) splice tray holder (FSTHE) and (2) splice 
trays (FST6) .
Dimensions 44.5mm H x 482.6mm W x 389.5mm D 

1

1

FMD48STMP

Assembled with (48) ST* Pigtails, (8) FAP6WST, (1)  splice
tray holder (FSTHE) and (4) splice trays (FST6) .
Dimensions 88.9mm H x 482.6mm W x 389.5mm D 

2

1

FMD48SCMP

Assembled with (48) SC Pigtails, (8) FAP3BUDSC, (1)
splice tray holder (FSTHE) and (4) splice trays (FST6). 
Dimensions 88.9mm H x 482.6mm W x 389.5mm D 

2

1

FMD48FJMP

Assembled with (24) duplex FJ

TM

Pigtails, (4) FMP6, (4)

FAPB, (1) splice tray holder (FSTHE) and (4) splice 
trays (FST6).
Dimensions 88.9mm H x 482.6mm W x 389.5mm D 

2

1

Panduit-Pannet-html.html
background image

114

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

O

PTICOM

Wall Mount Enclosures

• Include fibre optic cable routing accessory kit and label
• Separate doors for service and users sides with optional**

keyed locks for added security

• Accept 

O

PTICOM

Fibre Adapter Panels

• Compact design allows installation in tight areas

**Use enclosure lock part number FELU for user side or FELS for service side. 
Fibre Optic Cable Routing Accessory Kit containts various fibre optic cable management components such as

PANDUIT

cable ties, cable tie brackets, clips and grounding lugs. 

All product colour is black.

O

PTICOM

Pre-Terminated Wall Mount Enclosures

• Simplify installation process
• Factory terminated connectors with 2 metres 900μm 

jacketed cable (62.5/125μm)

• Include splice trays that accommodate mechanical or

fusion splices

All product colour is black.

FWME2

FWME4

FWME8

FWME12STMP

Part Number

Part Description

Std.

Pkg.

Qty.

FWME2

Accepts up to (2) FAP or FMP panels, (1) splice tray holder (FSTHS) and (2)
splice trays (FSTK). Supports up to (16) ST, (24) SC or (24) FJ fibre optic
terminations.
Dimensions 304.8mm H x 258.6mm W x 58.9mm D

1

FWME4

Accepts up to (4) FAP or FMP panels, (1) splice tray holder (FSTHS) and (4)
splice trays (FSTK). Supports up to (32) ST, (48) SC or (48) FJ fibre optic
terminations.
Dimensions 409.2mm H x 311.2mm W x 89.4mm D

1

FWME8

Accepts up to (8) FAP or FMP panels, (2) splice tray holders (FSTHS) and
(8) splice trays (FSTK). Supports up to (64) ST, (96) SC or (96) FJ fibre optic
terminations.
Dimensions 409.2mm H x 514.2mm W x 89.4mm D

1

Part Number

Part Description

Std.

Pkg.

Qty.

FWME12STMP

Assembled with (12) ST Pigtails, (2) FAP3WST, (1) FSTHS and (2)
FSTK. Dimensions 305mm W x 254mm H x 57mm D.

1

Panduit-Pannet-html.html
background image

115

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

O

PTICOM

Fibre Adapter Panels

• Snap quickly into the front of all 

O

PTICOM

Fibre Optic Enclosures

• Singlemode SC APC Adapters, 

M

INI

-

COM

SC APC Adapter modules and 

O

PTICOM

SC APC Fibre Adapter Panels are

manufactured in APC Green with zirconia ceramic split sleeves

FAP3WEIDSC

FAP6WST

FAP6WFCZ

FMP6WMTRJ

FAP6WEISC

FMP6**

FAP6WSTA

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Multi-Media Modular Panel

FMP6

Unloaded panel accepts up to (6) 

M

INI

-C

OM

Modules for Fibre

Optic, UTP, ScTP and Coax applications. Customise your
installation for multi-media applications requiring integration of fibre
optic and copper cables.

1

10

Simplex SC Fibre Adapter Panels

FAP6WEISC

Loaded with (6) electric ivory SC simplex adapters with phosphor
bronze split sleeves.

1

10

FAP6WBUSCZ

Loaded with (6) blue SC simplex adapters with ceramic sleeves.

1

10

Duplex SC Fibre Adapter Panels

FAP2WEIDSC

Loaded with (2) electric ivory SC duplex adapters with phosphor
bronze split sleeves.

1

10

FAP3WEIDSC

Loaded with (3) electric ivory SC duplex adapters with phosphor
bronze split sleeves.

1

10

FAP3WEIDSCA

Loaded with (3) electric ivory angled SC duplex adapters with
phosphor bronze split sleeves.

1

10

FAP4WEIDSC

Loaded with (4) electric ivory SC duplex adapters with phosphor
bronze split sleeves.

1

10

FAP6WEIDSC

Loaded with (6) electric ivory SC simplex adapters with phosphor
bronze split sleeves.

1

10

FAP2WBUDSCZ

Loaded with (2) blue SC duplex adapters with ceramic sleeves.

1

10

FAP3WBUDSCZ

Loaded with (3) blue SC duplex adapters with ceramic sleeves.

1

10

FAP4WBUDSCZ

Loaded with (4) blue SC duplex adapters with ceramic sleeves.

1

10

FAP6WBUDSCZ

Loaded with (6) blue SC duplex adapters with ceramic sleeves.

1

10

Simplex LC Fibre Adapter Panels

FAP12WBUDLCZ

Loaded with (12) blue LC duplex adapters with ceramic split sleeves.

1

10

Duplex LC Fibre Adapter Panels

FAP6WEIDLC

Loaded with (6) electric ivory LC duplex adapters with phosphor
bronze split sleeves.

1

10

FAP6WBUDLCZ

Loaded with (6) blue LC duplex adapters with ceramic sleeves.

1

10

Simplex ST* Fibre Adapter Panels

FAP6WST

Loaded with (6) ST* adapters with phosphor bronze split sleeves.

1

10

FAP6WSTA

Loaded with (6) angled ST* adapters with phosphor bronze split
sleeves.

1

10

FAP8WST

Loaded with (8) ST* adapters with phosphor bronze split sleeves.

1

10

FAP6WSTZ

Loaded with (6) ST* adapters with ceramic sleeves.

1

10

FAP8WSTZ

Loaded with (8) ST* adapters with ceramic sleeves.

1

10

FASSCZAG-L

SC APC Adapter simplex

1

10

FADSCZAG-L

SC APC Apapter duplex 

1

10

CMSAGSCZBL

SC APC Adapter Module simplex

1

10

CMDAGSCZBL

SA APC Adapter Module duplex

1

10

SC Adapters in APC Green

FAP6WAGSCZ

SC APC Fibre Adapter Panel 6 port simplex

1

10

FAP12WAGSCZ

SC APC Fibre Adapter Panel 12 port simplex 

1

10

FAP2WAGDSCZ

SC APC Fibre Adapter Panel 2 port duplex 

1

10

FAP3WAGDSCZ

SC APC Fibre Adapter Panel 3 port duplex

1

10

FAP4WAGSCZ

SC APC Fibre Adapter Panel 4 port duplex 

1

10

FAP2WAGDSCZ

SC APC Fibre Adapter Panel 6 port duplex 

1

10

FAP6WBUDSCZ

FAP6WAGDSCZ

Panduit-Pannet-html.html
background image

116

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

**Adapters not included

O

PTICOM

Pre-Terminated Cassettes

• Utilise same footprint as Fibre Adapter Panels to fit in any

O

PTICOM

Enclosure

• Factory assembled and tested connectors

• Insertion loss/return loss data provided
• Eliminate field connector terminations
• Significantly reduces installation time and labour

FC6STMFCM

FC8FJMFCS

MPO Cassettes used with MPO Fibre Optic Cords.
All product colour is black.

Simplex FC Fibre Adapter Panels

FAP6WFC

Loaded with (6) FC adapters with phosphor bronze split sleeves.

1

10

FAP6WFCZ

Loaded with (6) FC adapters with ceramic sleeves.

1

10

MT-RJ Fibre Adapter Panels

FMP6WMTRJ

Loaded with (6) electric ivory MT-RJ adapters.

1

10

FMP6WMTRJBL

Loaded with (6) black MT-RJ adapters.

1

10

Blank Fibre Adapter Panel

FAPB

Blank adapter panel - reserves space for future use.

1

10

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Opticom Pre-Terminated Cassettes with Multi-fibre Connectors
“Plug-N-Play” system - no splicing required Multimode MPO Cassettes

FC6STMFCM

Moulded fibre cassette with (6) front mounted ST* connectors to
rear mounted MPO 62.5/125μm

1

10

FC6SCMFCM

Moulded fibre cassette with (3) front mounted duplex SC
connectors to rear mounted MPO 62.5/125μm.

1

10

FC12SCMFCM

Moulded fibre cassette with (6) front mounted duplex SC
connectors to rear mounted MPO 62.5/125μm.

1

10

FC8FJMFCM

Moulded fibre cassette with (4) front mounted FJ connectors to rear
mounted MPO 62.5/125μm

1

10

Singlemode MPO Cassettes

FC6STMFCS

Moulded fibre cassette with (6) front mounted ST* connectors to
rear mounted MPO 9/125μm

1

10

FC6SCMFCS

Moulded fibre cassette with (3) front mounted duplex SC
connectors to rear mounted MPO 9/125μm.

1

10

FC12SCMFCS

Moulded fibre cassette with (6) front mounted duplex SC
connectors to rear mounted MPO 9/125μm.

1

10

FC8FJMFCS

Moulded fibre cassette with (4) front mounted FJ connectors to rear
mounted MPO 9/125μm

1

10

Opticom Pre-Terminated Cassettes with 5 metre Pigtail
Multimode Pigtail Cassettes

FC6STMP5

Moulded fibre cassette with (6) front mounted ST* connectors to
rear pigtail 62.5/125μm

1

10

FC6SCMP5

Moulded fibre cassette with (3) front mounted duplex SC
connectors (6 fibres) to rear pigtail 62.5/125μm.

1

10

FC8FJMP5

Moulded fibre cassette with (4) front mounted FJ connectors (8
fibres) to rear pigtail 62.5/125μm

1

10

FC12SCMP5

Moulded fibre cassette with (6) front mounted duplex SC
connectors (12 fibres) to rear pigtail 62.5/125μm.

1

10

Singlemode Pigtail Cassettes

FC6STSP5

Moulded fibre cassette with (6) front mounted ST* connectors to
rear pigtail 9/125μm

1

10

FC6SCSP5

Moulded fibre cassette with (3) front mounted duplex SC
connectors (6 fibres) to rear pigtail 9/125μm.

1

10

FC8FJSP5

Moulded fibre cassette with (4) front mounted FJ connectors (8
fibres) to rear pigtail 9/125μm

1

10

FC12SCSP5

Moulded fibre cassette with 6 front mounted duplex SC connectors
(12 fibres) to rear pigtail 9/125μm.

1

10

Panduit-Pannet-html.html
background image

117

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

O

PTICOM

Optical Component Module

• Provides instant access to monitor valuable optical circuits

without disconnecting or interrupting service

• Simplifies testing and troubleshooting

• Helps manage reliable service for customers
• Compatible with 

O

PTICOM

Enclosures

F6B-2-4JAKBBAA

O

PTICOM

Splice Trays and Holders

For use with either mechanical or fusion splices. 
Complete kit includes:

• Mechanical and fusion adhesive backed splice holders

(each splice holder holds 6 splices)

• Cable ties to help manage incoming and outgoing cable
• PVC tubing to protect buffered fibre upon exit or entry 

into tray

• One splice tray with protective cover.

FST24H3

FST24

FST6H4

FST6

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

F6B-2-4JAKBBAA

O

PTICOM

90/10 Wideband Singlemode Optical Splitter

Cassette, singlemode SC/UPC, monitors 2 singlemode fibre
cables, ports: 4 Front - 2 Rear.

1

10

F6B-2-4JAHBBAA

O

PTICOM

90/10 Wideband Singlemode Optical Splitter

Cassette, singlemode SC/UPC, monitors 2 singlemode fibre
cables, ports: 6 Front.

1

10

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Splice Tray Kit - For Trays, Drawers, Splice Enclosures, FWME4 and FWME8

FST6

Accommodates up to (12) mechanical or fusion splices. For use with
FSTHE or FST6H4 stacking unit. 
Dimensions 10.2mm H x 113.8mm W x 201.6mm L

1

10

Splice Tray Stacking Unit - For Trays and Drawers

FSTHE

FSTHED

FST24S

Holds and secures up to (4) splice trays (FST6). Can be mounted with
the use of adhesive strips or mounting screws included. Splice trays
held in place with 

PANDUIT

T

AK

-T

Y

Cable Ties. For use with FMT1,

FMT2, FMD1 or FMD2.
Dimensions 45mm H x 116mm W x 205mm L

1

10

FST6H4

Holds and secures up to (4) splice trays (FST6) with built in fibre
spooling. Mounts with existing hardware. Splice trays held in place
with 

PANDUIT T

AK

-T

Y

Cable Ties. 

Dimensions 80.77mm H x 117.60mm W x 201.42mm L

1

Splice Tray Kit - For FRME4

FST24

Accommodates up to (24) mechanical or fusion splices, or (144)
ribbon fusion splices. For use with FST24H3. 
Dimensions 9.5mm H x 298.5mm W x 111.4mm L

1

10

Holds and secures up to 4 FST24S splice tray. It’s used with FMT’s
Trays and FMD’s Drawers

Splice tray holds up to 24 mechanical or fusion splice

1

10

1

10

Splice Tray Stacking Unit - For FWME4 and FWME8

FSTHS

FSTK

Splice Tray Stacking Unit - For FRME4

FST24H3

Holds and secures up to (3) splice trays (FST24) with built in fibre
spooling. Mounting hardware included. Splice trays held in place with
PANDUIT T

AK

-T

Y

Cable Ties. 

Dimensions 52.6mm H x 295.0mm W x 115.8mm L

1

10

Splice Tray Kit - For FWME2

FSTK

Accommodates up to (6) mechanical or fusion splices. For use with
FSTHS stacking unit.
Dimensions 9.8mm H x 87mm W x 169mm L

1

10

Splice Tray Stacking Unit - For FRME2

FSTHS

Holds and secures up to (2) splice trays (FSTK) with built in fibre
spooling. Mounts with existing hardware. Splice tray held in place with
PANDUIT T

AK

-T

Y

Cable Ties. 

Dimensions 41mm H x 89mm W x 165mm L

1

10

Panduit-Pannet-html.html
background image

118

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Optical Fibre Network Saddle (Dual Capacity)

• Smooth rounded edges eliminates potential for snagging and stress on cable

• Accepts two bundles

Optical Fibre Network Saddle

• Use in pre-drilled 4mm holes in panels up to 2.2mm thick

• Smooth rounded edges eliminates potential for snagging

and stress on cable

Fibre Accessories

• Locks can be installed on 

O

PTICOM

Enclosure for added security

FEL

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FEL

Fibre enclosure lock for splice enclosures.

1

10

FELS

Fibre enclosure lock for service side.

1

10

FELU

Fibre enclosure lock for user side.

1

10

Part Number

Max. Bundle

Dia.*

Material

Mounting Method

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

VWSDC-C

26.9 

Nylon 6.6

Push Mount

Natural 

100

500

Part Number

Max. Bundle

Dia. 

Material

Mounting Method

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

VWS106-C

26.9

Nylon 6.6

Push Mount

Natural

100

500

Panduit-Pannet-html.html
background image

119

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Multimode 62.5/125μm or 50/125μm Patch Cords and Pigtails

• Designed and tested to pass all TIA/EIA-568-B.3 

performance requirements

• Insertion loss per connection: 0.10dB typical; 0.30dB maximum

• 100% factory tested for insertion loss

• Insertion loss data recorded for every multimode patch cord

• Lifetime traceability of test data to a QC number on each 

patch cord

• SC Duplex Patch Cords include SC Duplex Clips to 

maintain polarity

• Highest quality flame retardant fibre optic cable with tight buffered

coating on each optical fibre

• 62.5/125μm patch cord part numbers use F6 prefix; change to F5

prefix for 50/125μm patch cords

To order 50/125μm fibre optic patch cords, substitute the F6 in the part number (F6 D3-3M1) with F5 (F5 D3-3M1).
^Additional lengths and availability: Patch cords are available in 1, 2, 3, 5 and 10 metre lengths, and pigtails are available in 
1, 2 and 3 metre lengths. To order lengths other than 1 metre, substitute the 1 suffix in the part number (F6D3-3M 1) with the
desired length (F6D3-3M 2 for 2 metre length). Patch cords in 1, 2 and 3 metre lengths, and pigtails in 1 metre lengths are
stock items. 

F6D3-3M

F6S3-3M

F6B3-NM

F6E10-10M

F6B10-NM

F6D2-2M

F6S2-2M

F6D6P-6PM

F6D6J-NM

Self-Laminating Labels for Fibre Optic Patch Cords and Pigtails –
Multimode 62.5/125μm or 50/125μm

For complete labelling solutions and product information, reference the Labelling and Administration section on 
pages 349-356 and www.panduit.com
**All part number configurations on this page.

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Cord 

Part Number

Laser/Ink Jet Desktop Printer Label

P

ANTHER

LS8 

Hand-Held Thermal Printer

F6E10-NM

S100X160FAJ and NWSLC-2

S100X160VAC

F6S**-**M

S100X160FAJ and NWSLC-3

S100X160VAC

F6D**-**M

S100X225FAJ and NWSLC-7

S100X225VAC

F6D6P-6PM
F6D6J-NM

Part Number

Part Description

Length (M)

Additional

Lengths^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

SC to SC - Multimode Duplex Patch Cords - 3mm Jacketed Cable

F6D3-3M1

SC to SC multimode duplex patch cord, 3mm jacketed cable 
(two SC connectors on each end) - 62.5/125μm.

1

1

10

SC to SC - Multimode Simplex Patch Cords - 3mm Jacketed Cable

F6S3-3M1

SC to SC multimode simplex patch cord, 3mm jacketed cable 
(one SC connector on each end) - 62.5/125μm.

1

1

10

SC to Pigtail - Multimode Simplex Pigtails - 900μm Buffered Fibre

F6B3-NM1

SC to pigtail multimode simplex pigtail, 900μm buffered fibre 
(one SC connector on one end and open on the other end) - 62.5/125μm.

1

1

10

LC to LC - Multimode Duplex Patch Cords - 1.6mm Jacketed Cable

F6E10-10M1

LC to LC multimode duplex patch cord, 1.6mm jacketed cable 
(one duplex LC connector on each end) - 62.5/125μm.

1

1

10

LC to Pigtail - Multimode Simplex Pigtails - 900μm Buffered Fibre

F6B10-NM1

LC to pigtail multimode simplex pigtail, 900μm buffered fibre 
(one LC connector on one end and open on the other end) - 62.5/125μm.

1

1

10

ST* to ST* - Multimode Duplex Patch Cords - 3mm Jacketed Cable

F6D2-2M1

ST* to ST* multimode duplex patch cord, 3mm jacketed cable 
(two ST* connectors on each end) - 62.5/125μm.

1

1

10

ST* to ST* - Multimode Simplex Patch Cords - 3mm Jacketed Cable

F6S2-2M1

ST* to ST* multimode simplex patch cord, 3mm jacketed cable 
(one ST* connector on each end) - 62.5/125μm.

1

1

10

FJ Plug to FJ Plug - Multimode Duplex Patch Cords - 3mm Jacketed Cable

F6D6P-6PM1

FJ plug to FJ plug multimode duplex patch cord, 3mm jacketed cable 
(one FJ plug on each) - 62.5/125μm.

1

1

10

FJ Jack Module to Pigtail - Multimode Duplex Pigtails - 3mm Jacketed Cable

F6D6J-NM1

FJ jack module to pigtail multimode duplex patch cord, 3mm jacketed cable
(one FJ jack module on one end and open on the other end) - 62.5/125μm.

1

1

10

Panduit-Pannet-html.html
background image

120

Order number of pieces required, in multiples of Standard Package Quantity.

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.

Length (M)

Additional

Lengths^

Part Description

Part Number

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Cord 

Part Number

Laser/Ink Jet Desktop Printer Label

P

ANTHER

LS8 

Hand-Held Thermal Printer

F6D6P**-3M

S100X225FAJ and NWSLC-7

S100X225VAC

F6D2-3M
F6E3-10M
F6D6P-2M

*ST is a registered trademark
of Lucent Technologies

To order 50/125m fibre optic patch cords, substitute the F6 in the part number (F6 D3-3M1) with F5 (F5 D3-3M1).
^Additional lengths and availability: Patch cords are available in 1, 2, 3, 5 and 10 metre lengths, and pigtails are available in 
1, 2 and 3 metre lengths. To order lengths other than 1 metre, substitute the 1 suffix in the part number (F6D3-3M 1) with the
desired length (F6D3-3M 2 for 2 metre length). Patch cords in 1, 2 and 3 metre lengths, and pigtails in 1 metre lengths are
stock items.

F6B6J-NM

F6D6PW-3M

F6D6PX-3M

F6D6PY-3M

F6D6PZ-3M

F6D6PQ-3M

F6D2-3M

F6E3-10M

F6D6P-3M

F6D6P-2M

Self-Laminating Labels for Fibre Optic Patch Cords and Pigtails –
Multimode 62.5/125μm or 50/125μm

For complete labelling solutions and product information, reference the Labelling and Administration section on pages 349-356 
and www.panduit.com
** All F6D6P*-3M parts on this page.

FJ Jack Module to Pigtail – Multimode Duplex Pigtails – 900μm Buffered Fibre

F6B6J-NM1

FJ jack module to pigtail multimode duplex pigtail, 900μm buffered fibre (one
FJ jack module on one end and open on the other end) - 62.5/125μm.

1

1

10

FJ Plug (Keyed W) to SC – Multimode Duplex Patch Cords, 3mm Jacketed Cable

F6D6PW-3M1

FJ plug (keyed W - black) to SC multimode duplex patch cord, 3mm
jacketed cable (one keyed FJ plug on one end and two SC connectors on
the other end) - 62.5/125μm.

1

1

10

FJ Plug (Keyed X) to SC – Multimode Duplex Patch Cords – 3mm Jacketed Cable

F6D6PX-3M1

FJ plug (keyed X - red) to SC multimode duplex patch cord, 3mm jacketed
cable (one keyed FJ plug on one end and two SC connectors on the other
end) - 62.5/125μm.

1

1

10

FJ Plug (Keyed Y) to SC – Multimode Duplex Patch Cords – 3mm Jacketed Cable

F6D6PY-3M1

FJ plug (keyed Y - orange) to SC multimode duplex patch cord, 3mm
jacketed cable (one keyed FJ plug on one end and two SC connectors on
the other end) 62.5/125μm.

1

1

10

FJ Plug (Keyed Z) to SC – Multimode Duplex Patch Cords – 3mm Jacketed Cable

F6D6PZ-3M1

FJ plug (keyed Z - yellow) to SC multimode duplex patch cord, 3mm
jacketed cable (one keyed FJ plug on one end and two SC connectors on
the other end) 62.5/125μm.

1

1

10

FJ Plug (Keyed Q) to SC – Multimode Duplex Patch Cords – 3mm Jacketed Cable

F6D6PQ-3M1

FJ plug (universal keyed Q - white) to SC multimode duplex patch cord,
3mm jacketed cable (one keyed FJ plug on one end and two SC connectors
on the other end) - 62.5/125μm.

1

1

10

ST* to SC – Multimode Duplex Patch Cords – 3mm Jacketed Cable

F6D2-3M1

ST* to SC multimode duplex patch cord, 3mm jacketed cable (two ST*
connectors on one end and two SC connectors on the other end) -
62.5/125μm.

1

1

10

SC to LC – Multimode Duplex Patch Cords – 1.6mm Jacketed Cable

F6E3-10M1

SC to LC multimode duplex patch cord, 1.6mm jacketed cable (one duplex
SC connector on one end and one duplex LC connector on the other end) -
62.5/125μm.

1

1

10

FJ Plug to SC – Multimode Duplex Patch Cords – 3mm Jacketed Cable

F6D6P-3M1

FJ plug to SC multimode duplex patch cord, 3mm jacketed cable (one FJ
plug on one end and two SC connectors on the other end) - 62.5/125μm.

1

1

10

FJ Plug to ST* – Multimode Duplex Patch Cords – 3mm Jacketed Cable

F6D6P-2M1

FJ plug to ST* multimode duplex patch cord, 3mm jacketed cable (one FJ
plug on one end and two ST* connectors on the other end) - 62.5/125μm.

1

1

10

120

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Multimode 62.5/125μm or 50/125μm Patch Cords and Pigtails

(continued)

Panduit-Pannet-html.html
background image

121

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Fan-Out Cords – Multimode 62.5/125μm

^Patch cords available in 1, 2, 3 and 10 metre lengths.  To order lengths other than 1 metre, substitute 1 suffix
with 2, 3 or 10.

F612D3-NM

Part Number

Part Description

Length

(M)

^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Distribution Fibre Optic Cords - Six ST* Connectors to Pigtails

F66D2-NM1

ST* to pigtail six strand fibre optic cable (six ST* connectors
on one end and open on the other end on distribution cable) -
62.5/125μm.

1

1

10

Distribution Fibre Optic Cords - Six SC Connectors to Pigtails

F66D3-NM1

SC to pigtail six strand fibre optic cable (six SC connectors on
one end and open on the other end on distribution cable) -
62.5/125μm.

1

1

10

Distribution Fibre Optic Cords - Four FJ Jack Modules to Pigtails

F68D6J-NM1

FJ jack module to pigtail eight strand fibre optic cable (four FJ
jack modules on one end and open on the other end on
distribution cable) - 62.5/125μm.

1

1

10

Distribution Fibre Optic Cords - Twelve SC Connectors to Pigtails

F612D3-NM1

SC to pigtail twelve strand fibre optic cable (twelve SC
connectors on one end and open on the other end on
distribution cable) - 62.5/125μm.

1

1

10

Panduit-Pannet-html.html
background image

122

Order number of pieces required, in multiples of

Prime items appear in 

BOLD

.

MPO Fibre Optic Cords – Multimode 62.5/125μm

^Patch cords available in 1, 2, 3 and 10 metre lengths. To order lengths other than 1 metre, substitute 1 suffix with
2, 3 or 10.

F64D5-5M

F612D3-5M

*ST is a registered trademark of Lucent Technologies

Self-Laminating Labels for MPO Fibre Optic Cords –
Multimode 62.5/125μm

For complete labelling solutions and product information, For complete labelling solutions and product information,
reference the Labelling and Administration section on pages 349-356 www.panduit.com

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Cord

Part Number

Laser/Ink Jet Desktop Printer Label

P

ANTHER

LS8 

Hand-Held Thermal Printer

All MPO Fibre
Optic Cords
on this page

S100X160FAJ and NWSLC-3

S100X160VAC

Part Number

Part Description

Length 

(M)^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Four Strand Fibre Optic Cable – MPO to MPO

F64D5-5M1

MPO to MPO four strand fibre optic cable (one MPO
connector on each end on ribbon distribution cable) -
62.5/125μm.

1

1

10

Six Strand Fibre Optic Cable – MPO to MPO

F66D5-5M1

MPO to MPO six strand fibre optic cable (one MPO
connector on each end on ribbon distribution cable) -
62.5/125μm.

1

1

10

Eight Strand Fibre Optic Cable – MPO to MPO

F68D5-5M1

MPO to MPO eight strand fibre optic cable (one MPO
connector on each end on ribbon distribution cable) -
62.5/125μm.

1

1

10

Twelve Strand Fibre Optic Cable – MPO to MPO

F612D5-5M1

MPO to MPO twelve strand fibre optic cable (one MPO
connector on each end on ribbon distribution cable) -
62.5/125μm.

1

1

10

Six Strand Fibre Optic Cable – Six ST* Connectors to MPO

F66D2-5M1

ST* to MPO six strand fibre optic cable (six ST*
connectors on one end and one MPO connector on the
other end on ribbon distribution cable) - 62.5/125μm.

1

1

10

Six Strand Fibre Optic Cable – Six SC Connectors to MPO

F66D3-5M1

SC to MPO six strand fibre optic cable (six SC connectors
on one end and one MPO connector on the other end on
ribbon distribution cable) - 62.5/125μm.

1

1

10

Twelve Strand Fibre Optic Cable – Twelve SC Connectors to MPO

F612D3-5M1

SC to MPO twelve strand fibre optic cable (twelve SC
connectors on one end and one MPO connector on the
other end on ribbon distribution cable) - 62.5/125μm.

1

1

10

Eight Strand Fibre Optic Cable – Four FJ Jack Modules to MPO

F68D6J-5M1

FJ jack to MPO eight strand fibre optic cable (four FJ jack
modules on one end and one MPO connector on the other
end on ribbon distribution cable) - 62.5/125μm.

1

1

10

Panduit-Pannet-html.html
background image

123

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

O

PTI

-C

ORE

10

G

IG

50/125μm Patch Cords and Pigtails

• Patch cords are certified to support network transmission speeds 

up to 10 Gigabits per second for link lengths up to 300 metres 
with an 850nm source per IEEE 802.3ae 10GbE Standards

• Meets or exceeds TIA/EIA-568-B.3 performance requirements

• Insertion loss per connection: 0.10dB typical; 0.30dB maximum

• Backward compatible for use with all 50/125μm 

system requirements

• 100% factory tested and inspected for optimum performance

• Insertion loss data recorded for every multimode patch cord

• Lifetime traceablity of test data to a QC number on each 

patch code

• SC Duplex Patch Cords include SC Duplex Clips to 

maintain polarity

• Highest quality flame retardant fibre optic cable with tight-buffered 

coating on each optical fibre

If standard 50m performance (orange cable) is preferred, see pages XX-XX.
^Additional lengths and availability: Patch cords are available in 1, 2, 3, 5 and 10 metre lengths, and pigtails are available in 
1, 2 and 3 metre lengths. To order lengths other than 1 metre, substitute the 1 suffix in the part number (FXD3-3M 1) with the
desired length (FXD3-3M 2 for 2 metre length). Patch cords in 1, 2 and 3 metre lengths, and pigtails in 1 metre lengths are
stock items.

FXD3-3M

FXB3-NM

FXE10-10M

FXB10-NM

FXD6J-NM

FXD6P-6PM

Self-Laminating Labels for Fibre Optic Patch Cords and Pigtails –
O

PTI

-C

ORE

10G

IG

50/125μm

For complete labelling solutions and product information, For complete labelling solutions and product information, reference 
the Labelling and Administration section on pages 349-356 and www.panduit.com

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Cord 

Part Number

Laser/Ink Jet Desktop Printer Label

P

ANTHER

LS8 

Hand-Held Thermal Printer

FXD3-3M

S100X225FAJ and NWSLC-7

S100X225VAC

FXE10-10M

FXD6P-6PM

FXD6J-NM

Part Number

Part Description

Length (M)

Additional

Lengths^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

SC to SC - 10GbE Multimode Duplex Patch Cords - 3mm Jacketed Cable

FXD3-3M1

SC to SC multimode duplex patch cord, 10GbE, 3mm jacketed cable 
(two SC connectors on each end) - 50/125μm.

1

1

10

SC to Pigtail - 10GbE Multimode Simplex Pigtails - 900μm Buffered Fibre

FXB3-NM1

SC to pigtail multimode simplex pigtail, 10GbE, 900μm buffered fibre 
(one SC connector on one end and open on the other end) - 50/125μm.

1

1

10

LC to LC - 10GbE Multimode Duplex Patch Cords - 1.6mm Jacketed Cable

FXE10-10M1

LC to LC multimode duplex patch cord, 10GbE, 1.6mm jacketed cable
(one duplex LC connector on each end) - 50/125μm.

1

1

10

LC to Pigtail - 10GbE Multimode Simplex Pigtails - 900μm Buffered Fibre

FXB10-NM1

LC to pigtail multimode simplex pigtail, 10GbE, 900μm buffered fibre 
(one LC connector on one end and open on the other end) - 50/125μm.

1

1

10

FJ Plug to FJ Plug - 10GbE Multimode Duplex Patch Cords - 3mm Jacketed Cable

FXD6P-6PM1

FJ plug to FJ plug multimode duplex patch cord, 10GbE, 3mm jacketed
cable (one FJ plug on each end) - 50/125μm.

1

1

10

FJ Jack Module to Pigtail - 10GbE Multimode Duplex Patch Cords - 3mm Jacketed Cable

FXD6J-NM1

FJ jack module to pigtail multimode duplex pigtail, 10GbE, 3mm jacketed cable 
(one FJ jack module on one end and open on the other end) - 50/125μm.

1

1

10

Panduit-Pannet-html.html
background image

124

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.

Length (M)

Additional

Lengths^

Part Description

Part Number

FXB6J-NM

FXE3-10M

FXD6PQ-3M

FXD6PZ-3M

FXD6PY-3M

FXD6PX-3M

FXD6PW-3M

O

PTI

-C

ORE

10

G

IG

50/125μm Patch Cords and Pigtails (continued)

If standard 50m performance (orange cable) is preferred, see pages XX-XX.
^Additional lengths and availability: Patch cords are available in 1, 2, 3, 5 and 10 metre lengths, and pigtails are available in 
1, 2 and 3 metre lengths. To order lengths other than 1 metre, substitute the 1 suffix in the part number (FXD3-3M 1) with the
desired length (FXD3-3M 2 for 2 metre length). Patch cords in 1, 2 and 3 metre lengths, and pigtails in 1 metre lengths are
stock items.

Self-Laminating Labels for Fibre Optic Patch Cords and Pigtails –
O

PTI

-C

ORE

10G

IG

50/125μm

For complete labelling solutions and product information, For complete labelling solutions and product information, reference 
the Labelling and Administration section on pages 349-356 and www.panduit.com

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Cord 

Part Number

Laser/Ink Jet Desktop Printer Label

P

ANTHER

LS8 

Hand-Held Thermal Printer

All FX Parts on
this page

S100X225FAJ and NWSLC-7

S100X225VAC

FXD6P-3M

FJ Jack Module to Pigtail – 10GbE Multimode Duplex Patch Cords – 900μm Buffered Fibre

FXB6J-NM1

FJ jack module to pigtail multimode duplex pigtail, 10GbE, 900μm
buffered fibre (one FJ jack module on one end and open on the other
end) - 50/125μm.

1

1

10

FJ Plug (Keyed W) to SC – 10GbE Multimode Duplex Patch Cords – 3mm Jacketed Cable

FXD6PW-3M1

FJ plug (keyed W - black) to SC multimode duplex patch cord, 10GbE,
3mm jacketed cable (one keyed FJ plug on one end and two SC
connectors on the other end) - 50/125μm.

1

1

10

FJ Plug (Keyed X) to SC – 10GbE Multimode Duplex Patch Cords – 3mm Jacketed Cable

FXD6PX-3M1

FJ plug (keyed X - red) to SC multimode duplex patch cord, 10GbE, 3mm
jacketed cable (one keyed FJ plug on one end and two SC connectors on
the other end) - 50/125μm.

1

1

10

FJ Plug (Keyed Y) to SC – 10GbE Multimode Duplex Patch Cords – 3mm Jacketed Cable

FXD6PY-3M1

FJ plug (keyed Y - orange) to SC multimode duplex patch cord, 10GbE,
3mm jacketed cable (one keyed FJ plug on one end and two SC
connectors on the other end) - 50/125μm.

1

1

10

FJ Plug (Keyed Z) to SC – 10GbE Multimode Duplex Patch Cords – 3mm Jacketed Cable

FXD6PZ-3M1

FJ plug (keyed Z - yellow) to SC multimode duplex patch cord, 10GbE,
3mm jacketed cable (one keyed FJ plug on one end and two SC
connectors on the other end) - 50/125μm.

1

1

10

FJ Plug (Keyed Q) to SC – 10GbE Multimode Duplex Patch Cords – 3mm Jacketed Cable

FXD6PQ-3M1

FJ plug (universal keyed Q - white) to SC multimode duplex patch cord,
10GbE, 3mm jacketed cable (one keyed FJ plug on one end and two SC
connectors on the other end) - 50/125μm.

1

1

10

SC to LC – 10GbE Multimode Duplex Patch Cords – 1.6mm Jacketed Cable

FXE3-10M1

SC to LC multimode duplex patch cord, 10GbE, 1.6mm jacketed cable
(two SC connectors on one end and one duplex LC connector on the
other end) - 50/125μm.

1

1

10

FJ Plug to SC – 10GbE Multimode Duplex Patch Cords – 3mm Jacketed Cable

FXD6P-3M1

FJ plug to SC multimode duplex patch cord, 10GbE, 3mm jacketed cable
(one FJ plug on one end and two SC connectors on the other end) -
50/125μm.

1

1

10

Panduit-Pannet-html.html
background image

125

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Singlemode 9/125μm Patch Cords and Pigtails

• Passes all TIA/EIA-568-B.3 performance requirements

• 100% factory inspected end face geometry in compliance with

Telcordia GR-326-CORE, Issue 3

• Typical insertion loss per connection: 0.25dB

• UPC polished (55dB minimum return loss)

• 100% factory tested and inspected for insertion loss and 

return loss

• Insertion loss and return loss data recorded for every singlemode

patch cord

• Lifetime traceability of test data to a QC number on each 

patch cord

• Highest quality flame retardant fibre optic cable with tight-buffered

coating on each optical fibre

^Additional lengths and availability: Patch cords are available in 1, 2, 3, 5, 10, 12, 15, 25 and 30 metre lengths, and pigtails
are available in 1, 2 and 3 metre lengths. To order lengths other than 1 metre, substitute the 1 suffix in the part number 
(F9D3-3M 1) with the desired length (F9D3-3M 2 for 2 metre length). 
Not available in 12, 15, 25 or 30 metre lengths.

F9B3-NM

F9E10-10M

F9F10-10M

F9B10-NM

F9D2-2M

F9S2-2M

Self-Laminating Labels for Fibre Optic Patch Cords and Pigtails –
Singlemode 9/125μm

For complete labelling solutions and product information,For complete labelling solutions and product information, reference 
the Labelling and Administration section on pages 349-356 and www.panduit.com
**All part number configurations on this page.

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Cord 

Part Number

Laser/Ink Jet Desktop Printer Label

P

ANTHER

LS8 

Hand-Held Thermal Printer

F9F10-NM

S100X160FAJ and NWSLC-2

S100X160VAC

F9S**-**M

S100X160FAJ and NWSLC-3

S100X160VAC

F9D**-**M

S100X225FAJ and NWSLC-7

S100X225VAC

F9D**-**M

Part Number

Part Description

Length (M)

Additional

Lengths^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

SC to SC - Singlemode Duplex Patch Cords - 3mm Jacketed Cable

F9D3-3M1

SC to SC singlemode duplex patch cord (two SC connectors on each end) -
9/125μm.

1

1

10

SC to SC - Singlemode Simplex Patch Cords - 3mm Jacketed Cable

F9S3-3M1

SC to SC singlemode simplex patch cord (one SC connector on each end) -
9/125μm.

1

1

10

SC to Pigtail - Singlemode Simplex Pigtails - 900μm Buffered Fibre

F9B3-NM1

SC to pigtail singlemode simplex pigtail, 900μm buffered fibre (one SC
connector on one end and open on the other end) 9/125μm.

1

1

10

LC to LC - Singlemode Duplex Patch Cords - 1.6mm Jacketed Cable

F9E10-10M1

LC to LC singlemode duplex patch cord, 1.6mm jacketed cable (one duplex
LC connector on each end) - 9/125μm.

1

1

10

LC to LC - Singlemode Simplex Patch Cords - 1.6mm Jacketed Cable

F9F10-10M1

LC to LC singlemode simplex patch cord, 1.6mm jacketed cable (one LC
connector on each end) - 9/125μm.

1

1

10

LC to Pigtail - Singlemode Simplex Pigtails - 900μm Buffered Fibre

F9B10-NM1

LC to pigtail singlemode simplex pigtail, 900m buffered fibre (one LC
connector on one end and open on the other end) 9/125μm.

1

1

10

ST* to ST* - Singlemode Duplex Patch Cords - 3mm Jacketed Cable

F9D2-2M1

ST* to ST* singlemode duplex patch cord (two ST* connectors on each end)
- 9/125μm.

1

1

10

ST* to ST* - Singlemode Simplex Patch Cords - 3mm Jacketed Cable

F9S2-2M1

ST* to ST* singlemode simplex patch cord (one ST* connector on each end)
- 9/125μm.

1

1

10

Panduit-Pannet-html.html
background image

126

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.

Length (M)

Additional

Lengths^

Part Description

Part Number

*ST is a registered trademark of Lucent Technologies

F9B2-NM

^Additional lengths and availability: Patch cords are available in 1, 2, 3, 5, 10, 12, 15, 25 and 30 metre lengths, and pigtails
are available in 1, 2 and 3 metre lengths. To order lengths other than 1 metre, substitute the 1 suffix in the part number 
(F9D3-3M 1) with the desired length (F9D3-3M 2 for 2 metre length). Patch cords in 1, 2 and 3 metre lengths, and pigtails in
1 metre lengths are stock items.
Not available in 12, 15, 25 & 30m lengths 

Singlemode 9/125μm Patch Cords and Pigtails (continued)

F9D6P-6PM

F9D6J-NM

F9B6J-NM

F9D2-3M

F9S2-3M

F9E3-10M

F9F3-10M

F9D6P-3M

Self-Laminating Labels for Fibre Optic Patch Cords and Pigtails –
Singlemode 9/125μm

For complete labelling solutions and product information, For complete labelling solutions and product information, reference 
the Labelling and Administration section on pages 349-356 and www.panduit.com

Suggested Label Solutions for TIA/EIA-606-A Compliance

Patch Cord 

Part Number

Laser/Ink Jet Desktop 

Printer Label

P

ANTHER

LS8 

Hand-Held Thermal Printer

F9F3-10M

S100X160FAJ and NWSLC-2

S100X160VAC

F9S2-3M

S100X160FAJ and NWSLC-3

S100X160VAC

F9D6P-6PM

S100X160FAJ and NWSLC-7

S100X160VAC

F9D6J-NM

F9D2-3M

F9E3-10M

ST* to Pigtail – Singlemode Simplex Pigtails – 900μm Buffered Fibre

F9B2-NM1

ST* to pigtail singlemode simplex pigtail, 900μm buffered fibre (one ST*
connector on one end and open on the other end) 9/125μm.

1

1

10

FJ Plug to FJ Plug – Singlemode Duplex Patch Cords – 3mm Jacketed Cable

F9D6P-6PM1

FJ plug to FJ plug singlemode duplex patch cord (one FJ plug on each end)
- 9/125μm.

1

1

10

FJ Jack Module to Pigtail – Singlemode Duplex Patch Cords – 3mm Jacketed Cable

F9D6J-NM1

FJ jack module to FJ jack module singlemode duplex patch cord (one FJ
jack module on each end) - 9/125μm.

1

1

10

FJ Jack Module to Pigtail – Singlemode Duplex Pigtails – 900m Buffered Fibre

F9B6J-NM1

FJ jack module to pigtail singlemode duplex pigtail, 900m buffered fibre (one
FJ jack module on one end and open on the other end) 9/125μm.

1

1

10

ST* to SC – Singlemode Duplex Patch Cords – 3mm Jacketed Cable

F9D2-3M1

ST* to SC singlemode duplex patch cord (two ST* connectors on one end
and two SC connectors on the other end) - 9/125μm.

1

1

10

ST to SC – Singlemode Simplex Patch Cords – 3mm Jacketed Cable

F9S2-3M1

ST* to SC singlemode simplex patch cord, 3mm jacketed cable (one ST*
connector on one end and one SC connector on the other end) - 9/125μm.

1

1

10

SC to LC – Singlemode Duplex Patch Cords – 1.6mm Jacketed Cable

F9E3-10M1

SC to LC singlemode duplex patch cord, 1.6mm jacketed cable (one duplex
SC connector on one end and one duplex LC connector on the other end) -
9/125μm.

1

1

10

SC to LC – Singlemode Simplex Patch Cords – 1.6mm Jacketed Cable

F9F3-10M1

SC to LC singlemode simplex patch cord, 1.6mm jacketed cable (one SC
connector on one end and one LC connector on the other end) - 9/125μm.

1

1

10

FJ Plug to SC – Singlemode Duplex Patch Cords – 3mm Jacketed Cable

F9D6P-3M1

FJ plug to SC singlemode duplex patch cord (one FJ plug on one end and
two SC connectors on the other end) - 9/125μm.

1

1

10

Panduit-Pannet-html.html
background image

127

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

*ST is a registered trademark of Lucent Technologies

Fan-Out Cords Singlemode 9/125μm

^Patch cords available in 1, 2, 3 and 10 metre lengths.  To order lengths other than 1 metre, substitute 1 suffix
with 2, 3, or 10.

Part Number

Part Description

Length

(M)^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Distribution Fibre Optic Cords – Six ST* Connectors to Pigtails

F96D2-NM1

ST* to pigtail six strand fibre optic cable (six ST* connectors
on one end and open on the other end on distribution cable) -
9/125μm.

1

1

10

Distribution Fibre Optic Cords – Six SC Connectors to Pigtails

F96D3-NM1

SC to pigtail six strand fibre optic cable (six SC connectors on
one end and open on the other end on distribution cable)

1

1

10

Distribution Fibre Optic Cords – Four FJ

TM

Jack Modules to Pigtails

F98D6J-NM1

FJ jack module to pigtail eight strand fibre optic cable (four
FJ) jack modules on one end and open on the other end on
distribution cable) - 9/125μm.

1

1

10

Distribution Fibre Optic Cords – Twelve SC Connectors to Pigtails

F912D3-NM1

SC to pigtail twelve strand fibre optic cable (twelve SC
connectors on one end and open on the other end on
distribution cable) - 9/125μm.

1

1

10

MPO Fibre Optic Cords – Singlemode 9/125μm

F94D5-5M

F96D3-5M

MPOs utilise standard APC polish. SC utilise standard UPC polish.
^Patch cords available in 1, 2, 3 and 10 metre lengths. To order lengths other than 1 metre, substitute 1 suffix with
2, 3 or 10.

Part Number

Part Description

Length

(M)^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Four Strand Fibre Optic Cable – MPO to MPO

F94D5-5M1

MPO to MPO four strand fibre optic cable (one MPO
connector on each end on ribbon distribution cable) –
9/125μm.

1

1

10

Six Strand Fibre Optic Cable – MPO to MPO

F96D5-5M1

MPO to MPO six strand fibre optic cable (one MPO
connector on each end on ribbon distribution cable) –
9/125μm.

1

1

10

Eight Strand Fibre Optic Cable – MPO to MPO

F98D5-5M1

MPO to MPO eight strand fibre optic cable (one MPO
connector on each end on ribbon distribution cable) –
9/125μm.

1

1

10

Twelve Strand Fibre Optic Cable – MPO to MPO

F912D5-5M1

MPO to MPO twelve strand fibre optic cable (one MPO
connector on each end on ribbon distribution cable) –
9/125μm.

1

1

10

Six Strand Fibre Optic Cable – Six ST* Connectors to MPO

F96D2-5M1

ST* to MPO six strand fibre optic cable (six ST*
connectors on each end and one MPO connector on the
other end on ribbon distribution cable) – 9/125μm.

1

1

10

Six Strand Fibre Optic Cable – Six SC Connectors to MPO

F96D3-5M1

SC to MPO six strand fibre optic cable (six SC connectors
on each end and one MPO connector on the other end on
ribbon distribution cable) – 9/125μm.

1

1

10

Twelve Strand Fibre Optic Cable – Twelve SC Connectors to MPO

F912D3-5M1

SC to MPO twelve strand fibre optic cable (twelve SC
connectors on one end and one MPO connector on the
other end on ribbon distribution cable) – 9/125μm.

1

1

10

Eight Strand Fibre Optic Cable – Four FJ Jack Modules to MPO

F98D6J-5M1

FJ jack module to MPO eight strand fibre optic cable (four
FJ jack modules on one end and one MPO connector on
the other end on ribbon distribution cable) – 9/125μm.

1

1

10

Panduit-Pannet-html.html
background image

128

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Furcation Kits

• Used to build up 900μm fibre to 3mm jacketed fibre to

strengthen and protect the fibre

• Kits include furcation tubing with strength members and

heat shrink

• Length: 1 metre

FJ Loopback Connector Assemblies

• FJ Jack Module ports can be tested using the FJ Loopback
• Each FJ Loopback includes and FJ Plug
• All FJ Loopback Connector Assemblies share the 

same performance as our singlemode and multimode
patch cords

• Available in multimode (62.5/125μm) and singlemode

(9/125μm) using 3mm tight-buffered jacketed cable

• Network interfaces are simulated via the FJ Loopback by

sending the transmit signal to the receive signal

• Tests both links (duplex) simultaneously at a single port
• Allows source and metre to remain at one location

FLB-6P-6S-PA

FLB-6P-9S-UA

FK2BJ

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FK2BJ

Build up 900μm fibre to 3mm jacketed fibre. For two fibres.

1

10

FK4BJ

Build up 900μm fibre to 3mm jacketed fibre. For four fibres.

1

10

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FLB-6P-6S-PA

FJ Multimode Loopback with FJ Duplex Plug with PC polish.

1

10

FLB-6P-9S-UA

FJ Singlemode Loopback with FJ Duplex Plug with UPC polish.

1

10

250 Micron Fibre Build-Up Tube Kit

• Includes 100 build-up tubes and supplemental instructions for 

terminating 

PANDUIT

Field Polish or 

O

PTI

-C

RIMP

Fibre Optic

Connectors onto 250μm coated fibre

• Used with 900μm boots included with connectors and the current

fibre optic termination kit

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

F250BT-C

250 micron fibre build-up tube kit; includes 100 build-up tubes and
supplemental installation instructions.

100

0

Panduit-Pannet-html.html
background image

129

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

SC Terminator

• Singlemode SC/UPC Optical Terminator for both 1310nm

and 1550nm 

• Terminates unused ports to reduce back reflectance to

improve network performance

• Return loss: 55dB min (UPC)
• FOCIS-3 compliant
• Meets/exceeds EIA/TIA-568-B.3

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FTRM-SC1

SC/UPC Singlemode Fibre Optic Terminator (1310/1550nm).

1

10

L

ABEL

C

ORE

Fibre Optic Cable Identification System

• Made of flexible PVC material
• Provides a larget labelling surface on small cables allowing

legends to be clearly seen

• Locate on straight section of cable at least 2 from fibre boot

* Order number of sleeves required.
For installation instructions please refer to page 352 in the Labelling and Administration section.

Part Number

Part Description

Std.

Pkg.

Qty.*

Std.
Ctn.
Qty.

NWSLC-2

Cable identification sleeve, 2mm cable, yellow.

100 1000

NWSLC-3

Cable identification sleeve, 3mm cable, orange.

100 1000

NWSLC-7

Cable identification sleeve for 3mm duplex fibre cable, white.

100 1000

Panduit-Pannet-html.html
background image

130

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

NOTES

Panduit-Pannet-html.html
background image

131

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

R

ACKS AND

C

ABLE

M

ANAGEMENT

PANDUIT

is a world leader in high quality racks and cable management solutions for

telecommunication equipment rooms and premises wiring applications. As the demand for system

performance increases, it becomes essential to protect and manage cables in order to maintain

system reliability.

PANDUIT

continues to provide innovative products that create the ultimate

solutions for managing, protecting and showcasing your network.

PANDUIT

offers a wide variety of racks and cable management products that organise and protect

your network as it expands while maintaining a professional appearance.Features such as integral

bend radius control and cable retainers contribute to make the 

N

ET

M

ANAGER

horizontal cable

manager the new standard. Integral bend radius control and large capacity options contribute to

make the 

P

ATCH

R

UNNER

Vertical Cable Manager the solution that maximises density in minimal

floor space. The 

N

ET

F

RAME

Rack System provides a heavy-duty solution with a large selection of

accessories that allow it to be used in a variety of applications.

PANDUIT

provides all of the options

necessary to handle the most demanding installations while providing the flexibility to facilitate

system upgrades now and in the future.

Multiple options allow user to configure system to
their preferences

Integral bend radius control helps protect cable from
being pinched, crushed or strained 

Easy access to cable pathways simplifies moves, adds
and changes while allowing the user to maintain an
organised system

Modular design allows for use with all

P

AN

-N

ET

products to provide an aesthetically

pleasing solution

• Easy field installation of components provides the

lowest installed cost

Panduit-Pannet-html.html
background image

132

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Footprint for 

N

ET

F

RAME

Rack 

N

ET

F

RAME

Cable Management Rack System Roadmap

(50.8mm)

Rack Height 
(2184.4mm)

(721.4mm)

Front of Rack

(152.4mm)

(279.4mm)

NFR84

Panduit-Pannet-html.html
background image

133

N

ET

F

RAME

Rack — 7'

NFR84 (page 132)

2

4

5

1

7

8

9

3

6

1

Fibre Spool Kit
NFSK (page134)

3

Hinged Door (1 each)
NFD484 (page 134)

D-ring Kit (8 each), 4x6 — 
Capacity: 275 cables (.187 dia)
NFDR4X6K (page 134)

2

4x5 Duct with Cover —
Capacity: 240 cables (.187 dia)
NFVD4X584 (page134)

4

N

ET

F

RAME

Shelf

NFSHLF19X18 (page 134)

6

Vertical Slack Manager
NFVSM (page134)

8

Ladder Rack Support Bracket
NFLRB (page134)

7

End Panel
NFEP (page 134)

9

5

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

134

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

N

ET

F

RAME

Rack System

• Rack is UL listed for 682kg load rating to accommodate

large networking equipment

• Pass through holes on front and side of channels provide

convenient patching front to back or between rack

• Heavy duty shelves available to accommodate 

network equipment

• Deep vertical channel design provides distribution 

cable pathway

• Top channel provides pathway for ladder rack

• Compatible with horizontal cable management panels,

Opticom Fibre Optic Enclosures and 

M

INI

-C

OM

Rack 

Mount Products

• Easy field installations
• Multiple vertical cable management options are simple 

to install and allow users to configure system to 
their preferences

• Optional full length hinged metal door provides easy

access to vertical pathway

^One rack space = 44.45mm
All product colour is black.

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

N

ET

F

RAME

Rack

NFR84

NetFrame Rack, 2133.6mm H

45

1

N

ET

F

RAME

Rack Accessories

NFD484

Hinged door 101.6mm x 2133.6mm

45

1

NFDR4X6K

D-ring kit (8) 101.6mm x 152.4mm

1

NFVD4X584

NetFrame duct accessory, front only. Dimensions
100mm W x 125mm D x 2133mm H

45

1

NFSK

Fibre spool kit, 1 spool with hardware.

1

10

NFSHLF19X25

NetFrame shelf 19” mount x 635mm deep

1

1

NFSHLF19X18

NetFrame shelf 19” mount x 457.2mm deep

1

1

NFVSM

Vertical slack manager, front only.

1

NFEP

End panel

1

NFLRB

Ladder rack support bracket

1

NetRack Cable Management System and Accessories

• Modular System with 19" or 23" EIA rack mounting
• Base rack includes 23” width (19" mounting) to allow user

to stay within the footprint of a 600m floor tile in stand-
alone and bayed configurations

• Optimised for use in data centres to support active equip-

ment and manage network cabling.

• Vertical cable management options include plastic vertical

d-rings and slotted duct

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

DR84

NetRack Cable Management Rack System 19”  
or 23” x 2133.6mm

1

DRD284

50.8mm x 2133.6mm hinged metal door

1

CMVDR1-8

50.8mm x 127mm vertical d-ring kit

8

WMPVFM45

Front only, slotted duct 101.6mm x 127mm

1

Panduit-Pannet-html.html
background image

135

4 Post Rack and Accessories

• Rack features 19” or 23” EIA mounting
• Adjustable rear mounting rails provide a mounting depth of

304.8mm to 787.40mm

• Rack space identification stamped into rails at each 

rack space

• Base can be setup 610mm x 610mm for raised 

floor applications

• Top waterfall
• Multiple holes on top cross braces accommodate up to

381mm ladder rack 454.5kg load rating

• Two vertical cable management options

All product colour is black.

NF4PR84

NF4PDR2X6K

NF4PSHLF19

NF4PVD2X5

NF4PR84 Rack Footprint

Part Number

Part Description

No. of

Rack

Spaces

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

4 Post Rack

NF4PR84

4 post rack, 2134mm

45

1

4 Post Rack Accessories

NF4PDR2X6K

4 post rack d-ring kit (8) 50.8mm x 152.4mm.

1

10

NF4PVD2X5

4 post rack, 2 x 5 vertical duct accessory, front only.
Dimensions 50.8mm x 127mm x 177.8mm

45

1

NF4PSHLF19

4 post rack shelf 19” (482.60mm)
Dimensions 43.1mm H x 482.60mm W x 815.30mm D

1

1

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

136

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Footprint for Standard Equipment Rack with NCMV12 and NCMVF12

P

ATCH

R

UNNER

Vertical Cable Management Rack System Roadmap

(2129mm)

NCMVF12

(2129mm)

NCMV12

Panduit-Pannet-html.html
background image

137

Standard Equipment Rack — 19" x 2133.60mm
CMR19X84 (page 142)

1

1

Managers with Front Doors
NCMV12 — 304.8mm Wide (page 136)

2b

Rear Door
NCMV8RD — 203.20mm Wide (page 137)

3

Managers with Front Doors
NCMV8 — 203.2mm Wide (page 137)

2a

Angled Patch Panel
CPPLA48WBL — 2RU, 48 Port (page 60)

4

End Panel
PREP (page 138)

5

2b

3

2a

4

5

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

138

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

ATCH

R

UNNER

Vertical Cable Management System

• Moulded cable management fingers with integral bend

radius control supports cable as it transitions from patch
panel to vertical pathway without the need for horizontal
cable managers

• Finger spacing aligns with the rack spaces simplifying 

cable routing

• Four modular cable management spools organise and

manage slack for 8 and 12 product allowing standarisation
of patch cord lengths

• Dual hinged full length door optional
• Angled modular patch panel provides optimal patch cord

bend radius control

• Rack spacing identification and load rating of 364kg 

provided when mounted to 

PANDUIT

Standard 

Equipment Rack

All product colour is black.

PRVF12

Capacity Chart

Part Number

Description

Front

4.74mm Dia. Cable

Back

PRV12

PRVF12

PRV8

PRVF8

PRV6

PRVF6

304.8mm wide front/back

304.8mm wide front

203.2mm wide front/back

203.2mm wide front

152.4mm wide front/back

152.4mm wide front/back

960

960

640

N/A

320

N/A

250

N/A

480

480

380

380

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

P

ATCH

R

UNNER

Vertical Managers - Manages cable on front and rear of rack

PRV6

Vertical cable manager. 152.4mm x 2139.6mmH

1

PRV8

Vertical cable manager. 203.2mm x 2139.6mmH

1

PRV12

Vertical cable manager. 304.8mm x 2139.6mmH

1

P

ATCH

R

UNNER

Vertical Managers - Manages cable on front of rack only

PRVF6

Vertical cable manager, front only. 152.4mm x  2139.6mmH

1

PRVF8

Vertical cable manager, front only. 203.2mm x 2139.6mmH

1

PRVF12

Vertical cable manager, front only. 304.8mm x 2139.6mmH

1

P

ATCH

R

UNNER

Accessories

PRSP7

177.8mm Dia. PatchRunner Spool

1

10

PREP

PatchRunner End Panel

1

10

P

ATCH

R

UNNER

- Additional Doors

PRD6

Dual hinged door. 152.4mmW

1

PRD8

Dual hinged door. 203.2mmW

1

PRD12

Dual hinged door. 304.8mmW

1

Panduit-Pannet-html.html
background image

139

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

4 space Stackable Cable Rack Spacers
CRS4-125-X (page 152)

9

10

1

1 space Stackable Cable Rack Spacers
CRS1-125-X (page 152)

2

Waterfall Kit
CMW-KIT (page 152)

3

Waterfall Base
CMWB (page 152)

4

Threaded Rod Cover
TRC18FR-X8 (page 214)

5

1" = 25.4mm Vertical D-ring
CMVDR1 (page 150)

6

1" = 50.8mm Short Vertical D-ring
CMVDR1S (page 150)

7

Centre Mounted Vertical D-ring
CMVDRC (page 150)

8

50.8mm Vertical D-ring
CMVDR2 (page 150)

9

50.8mm Short Vertical D-ring
CMVDR2S (page 150)

10

6

7

Communication Cable Management Accessories Roadmap

8

5

1

4

2

3

Panduit-Pannet-html.html
background image

140

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Footprint for Standard Rack

with 4x5 Vertical Managers

Footprint for Standard Rack

with 6x8 Vertical Managers

Standard Cable Management Rack System Roadmap

(2108.2mm)

WMPVF45

(2108.2mm)

WMPV45

53.8mm

TYP

53.8mm

TYP

177.8mm
WMPV45

with

WMPVCB

222.25mm
WMPV6X8

with

WMPVCB

Panduit-Pannet-html.html
background image

141

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Standard Equipment Rack 
CMR19X84 (page 142)

1

1

Standard Vertical Cable Managers
WMPV45 (page 140)

2a

Standard Vertical Cable Managers
WMPV6X8 (page 145)

2b

Centre Bracket Kit (4 brackets included) —
Use when mounting between racks
WMPVCB (page 145)

3

3

2b

Standard Equipment Rack

Spacing Identification

Panduit-Pannet-html.html
background image

142

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Standard Racks and Accessories

• Can be used with all 

PANDUIT

cable management and

patch panel products in addition to any industry standard
19" or 23" components

• Aluminium racks feature individually printed rack 

space numbering

• Aluminium racks equipped with pre-installed hardware for

quick assembly

• Double-sided #12-24 EIA universal mounting hole spacing
• #12-24 mounting screws included, qty 25
• 363kg load rating for 2133.6mm racks

^One rack space = 44.45mm
All product colour is black.

CMR19X84

CMLT19

CMUT19

Part Number

Part Description

No. of Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Standard Channel Racks

CMR19X84

19" standard rack 2133.6mm aluminium.

45

1

CMR19X84S

Standard EIA 19" rack 2133.6mm, steel.

45

1

CMR23X84

23" standard rack, 2133.6mm, aluminium.

45

1

CMR19X47

19" standard rack 1194mm aluminium.

24

1

CMR19X26

19" standard rack, 660mm aluminium

13

1

S1224-C

Package of 100 12-24 mounting screws

100 1000

Rack Mount Troughs

CMLT19

Lower trough mounts to the bottom of a 19" rack. Provides
bend radius control and additional facility for routing cable
from one rack to another.

4

1

CMUT19

Upper trough mounts to the top of a 19" rack. Provides
bend radius control and additional facility for routing cable
from one rack to another.

2

1

Rack Mountable Troughs

• Provide pathways to route cable from one side of a rack 

to the other or between racks (when bayed together)

• Offer greater flexibility when configuring network layout
• Integral waterfalls protect cable from crushing, ensuring

system reliability 

• Mount to channels of standard EIA 19” racks to create 

‘in-rack’ pathway

• Allow easy moves, adds and changes
• Eliminates need to route underfloor or overhead cables

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CRTW

Rack Top Trough with Waterfall

1

CMT4

Bottom Cable Management Trough

1

CRTW

CMT4

Panduit-Pannet-html.html
background image

143

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

SRM19CMV3

SRM19MPK2

SRM23MK2

Shelves

• Options with load ratings up to 90kg suitable for use with

lightweight and heavyweight active and passive equipment

• Options for standard (20 wide) or compact 

(16.5 wide) keyboards

• Slide out mouse pad integral to all keyboard shelves

SRM19FM2

^One rack space = 44.45mm
All product colour is black.

Panel Extender Brackets

• Allows for mounting 19" product on 23" EIA racks 

or cabinets

• Offset bracket design maintains flush mounting of panels

• Mounting hardware included

PEB1

PEB2

All product colour is black.

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Rack Mount Shelves

SRM19FM1

Front mount shelf, steel. 
Dimensions 43.9mm H x 482.7mm W x 384.8mm D, 1 RU
Load rating 13.5kg.

1

1

SRM19FM2

Front mount shelf, steel. 
Dimensions 88.4mm H x 482.65mm W x 384.8mm D, 2 RU
Load rating 22.7kg.

2

1

SRM19CMV3

Cantilevered shelf, vented, aluminium. 
Dimensions 132.8mm H x 488.7mm W x 316.2mm D, 3 RU
Load rating 90kg.

3

1

SRM19CM3

Cantilevered shelf, aluminium. 
Dimensions 132.8mm H x 488.7mm W x 316.2mm D, 3 RU
Load rating 90kg.

3

1

Keyboard Shelves

SRM19MPK2

Rack mount shelf with pivotting keyboard tray and mousepad,
aluminium. Dimensions 87.17mm H x 431.8mm W x 609.6mm D

2

1

SRM19MK2

Rack mount shelf with keyboard tray, aluminium. 
Dimensions 87.17mm H x 431.8mm W x 469.33mm D

2

1

SRM23MK2

Rack mount shelf with pivotting keyboard tray and mousepad,
aluminium. 
Dimensions 87.17mm H x 533.4mm W x 469.33mm D

2

1

Part Number

Part Description

No. of

Rack

Spaces

Std.

Pkg.

Qty.

PEB1

Converts horizontal panels.

1

1

PEB2

Converts horizontal panels.

2

1

PEB22

Converts rack from 23" to 19"

22

1

PEB44

Converts rack from 23" to 19"

44

1

Panduit-Pannet-html.html
background image

144

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Hinged Wall Brackets

• Mount to wall or standard EIA 19" racks
• Integral cable tie slots manage cable slack
• EIA hole spacing
• Hinge allows easy access to cabling
• Opening on base allows for cable access through wall

• Stackable for larger installations
• Includes white write-on labelling area
• Accepts #12-24 EIA universal mounting hole spacing
• Quick release hinged design for fast moves, adds 

and changes

WBH1

WBH2

WBH3

WBH4

WBH4E

^One rack space = 44.45mm
All product colour is black.

Filler Panels

• Filler panels reserve rack space for future use and help

keep installations manageable by acting as a divider

• Mounts to standard EIA 19" racks or cabinets

• Stackable
• Includes #12-24 mounting screws

DPFP1

DPFP2

DPFP4

DPFP8

^One rack space = 44.45mm
All product colour is black

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

152mm Deep Wall Brackets

WBH1

Hinged wall bracket, 1RU. 
Dimensions 44.5mm H x 507.9mm W x 155.8mm D

1

1

WBH2

Hinged wall bracket, 2RU. Dimensions 88.9mm H x 507.9mm W x
155.8mm D. Load rating 9 kgs

2

1

WBH3

Hinged wall bracket, 3RU. 
Dimensions 133.4mm H x 507.9mm W x 155.8mm D.

3

1

WBH4

Hinged wall bracket, 4RU. Dimensions 177.8mm H x 507.9mm W x
155.8mm D. Load rating 18 kgs

4

1

381mm Deep Wall Brackets

WBH2E

Hinged wall bracket, 2RU. Dimensions 88.9mm H x 518.7mm W x
401.5mm D. Load rating 9 kgs

2

1

WBH4E

Hinged wall bracket, 4RU. Dimensions 177.8mm H x 518.7mm W x
401.5mm D. Load rating 18 kgs

4

1

WBH6E

Hinged wall bracket, 6RU. Dimensions 266.7mm H x 518.7mm W x
401.5mm D. Load rating 27 kgs

6

1

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

DPFP1

Filler panel, 1RU. Dimensions 43.7mm H x 482.6mm W

1

1

10

DPFP2

Filler panel, 2RU. Dimensions 88.1mm x 482.6mm

2

1

10

DPFP4

Filler panel, 4RU. Dimensions 177.0mm H x 482.6mm W

4

1

10

DPFP8

Filler panel, 8RU. Dimensions 354.8mm H x 482.6mm W

8

1

10

Panduit-Pannet-html.html
background image

145

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Standard Vertical Slotted Duct

• Standard bracket allows side mounting WMPVCB kit option

allows mounting to adjacent racks

• Duct finger progression equivalent to one rack space

(44.45mm), allowing clear pathway between horizontal and
vertical cable management when finger is removed

• Organises cables on front and rear of 

telecommunication racks

• Rear mount options for use with standard 3 channel racks
• Front mount options for standard deep channel racks

• Covers are easily removable so cables are accessible for

quick revisions

• Panel supplied as side mount version
• Supplied with mounting brackets, screws and covers
• Cables pass through holes for front to rear cabling
• Wire retainer holds cable in place when cover is removed

^One rack space = 44.45mm
All product colour is black.

WMPVCB

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Rear Mount - Manages Cables on Front and Rear of Rack

WMPV3X5

Includes duct on front and rear. 
Dimensions 76.2mm W x 127mm D x 2108.2mm H

45

1

WMPV20

Includes duct on front and rear. 
Dimensions 102mm W x 127mm D x 889mm H

20

1

WMPV45

Includes duct on front and rear. 
Dimensions 102mm W x 127mm D x 2108.2mm H

45

1

WMPV50

Includes duct on front and rear. 
Dimensions 102mm W x 127mm D x 2413mm H

50

1

WMPVHC45

Includes duct on front and rear. 
Dimensions 152mm W x 203.2mm D x 2108.2mm H

45

1

WMPV6X8

Includes duct on front and rear. 
Dimensions 152.4mm W x 203.2mm D x 2108.2mm H

45

1

Rear Mount - Manages Cables on Front of Rack Only

WMPVF3X5

Includes duct on front only. 
Dimensions 76.2mm W x 127mm D x 2108.2mm H

45

1

WMPVF20

Includes duct on front only. 
Dimensions 102mm W x 127mm D x 889mm H

20

1

WMPVF45

Includes duct on front only. 
Dimensions 102mm W x 127mm D x 2108.2mm H

45

1

WMPVHCF45

Includes duct on front only. 
Dimensions 152mm W x 203.2mm D x 2108.2mm H

45

1

WMPVF6X8

Includes duct on front only. 
Dimensions 152mm W x 203.2mm D x 2108.2mm H

45

1

Centre Mount Kit

WMPVCB

Bracket kit to mount vertical cable managers to and between
two adjacent racks. Includes four brackets. Not for use with
WMPV3X5, WMPVF3X5, WMPVFM45, and WMPVFMHC45.

1

Front Mount - Manages Cables on Front of Rack Only

WMPVFM45

Includes duct on front only. 
Dimensions 102mm W x 127mm D x 2108.2mm H

45

1

WMPVFMHC45

Includes duct on front only. 
Dimensions 152mm W x 152mm D x 1208mm H

45

1

Angled Filler Panels

• Aesthetic design provides a clean and consistent look when used with 

PANDUIT

Angled Patch Panels

^ One rack space = 1.75” (44.45mm)

Part Number

Part Description

No. of Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CPAF1BL

Covers one open rack space in standard EIA
19” rack.

1

1

10

CPAF2BL

Covers two open rack spaces in standard EIA
19” rack.

2

1

10

Panduit-Pannet-html.html
background image

146

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

IN-Cabinet Vertical Cable Managers

• For managing cable within cabinets 685mm or wider
• Easy to install to cabinet vertical mounting rails

• Two mounting bracket options to facilitate mounting to 

various cabinet configurations

• Covers included

^One rack space = 44.45mm
All product colour is black.

SIDE

MOUNT

BRACKET

FRONT

MOUNT

BRACKET

CWMPV2318

CWMPV3440

CWMPHF1

Communication Cable Management Kit for Cabinets

• Kit of cable management accessories specifically designed for use in a network cabinet or enclosure

*Order the number of kits required

 

36.36

121.92

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Side Mount Vertical Panels - Front Only

CWMPV3440

Duct with side mount bracket, cage nut and screws. Dimensions
76mm W x 102mm D x 1829mm H. 4.75mm Dia cable capacity = 96

40

1

CWMPV3418

Duct with side mount bracket, cage nut and screws. Dimensions
76mm W x 102mm D x 813mm H. 4.75mm Dia cable capacity = 96

18

1

CWMPV2440

Duct with side mount bracket, cage nut and screws. Dimensions
51mm W x 102mm D x 1829mm H. 4.75mm Dia cable capacity = 60

40

1

CWMPV2418

Duct with side mount bracket, cage nut and screws. Dimensions
51mm W x 102mm D x 813mm H. 4.75mm Dia cable capacity = 60

18

1

Front Mount Vertical Panels - Front Only

CWMPV2340

Duct with front mount bracket. Dimensions 51mm W x 76mm D x
829mm H. 4.75mm Dia cable capacity = 48

40

1

CWMPV2318

Duct with front mount bracket. Dimensions 51mm W x 76mm D x
813mm H 4.75mm Dia. cable capacity = 48 

18

1

CWMPV3340

Duct with front mount bracket. Dimensions 76mm W x 76mm D x
1829mm H. 4.75mm Dia cable capacity = 72

40

1

CWMPV3318

Duct with front mount bracket. Dimensions 76mm W x 76mm D x
813mm H. 4.75mm Dia cable capacity = 72

18

1

Front Mount Horizontal Panels

CWMPH1

19" Horizontal wire management panel with duct front and back.
Dimensions 43.7mm H x 144.8mm D x 482.6mm W .187 Dia. cable
capacity = 24 front, 36 back

1

1

CWMPHF1

19" Horizontal wire management panel with duct front only.
Dimensions 43.7mm H x 40.6mm D x 482.6mm W .187 Dia. cable
capacity = 24 front

1

1

Part Number

Part Description

Std.

Pkg.

Qty.*

Std.
Ctn.
Qty.

CCMKIT1

Kit includes the following:
24 Nylon Cable Ties
12 Adhesive Backed Cable Tie Mounts
1 Roll (4.5m) 8.38mm. 

TAK-TY

Cable Ties 

8 Flat Pan-Post Standoffs for use with Std. Nylon Cable Ties
4 Vertical Wire Saddles
6 Push Style Cable Tie Mounts

1

100

CCMKIT2

Kit includes the following:
1 Roll (4.5m) 0.75. 

T

AK

-T

Y

Cable Ties

12 Nylon Cable Ties
6 Adhesive Backed Cable Tie Mounts
6 Adhesive Backed Mounts for 0.75 

T

AK

-T

Y

Cable Ties 

6 Screw Mounts for 0.75 

T

AK

-T

Y

Cable Ties

4 Vertical Wire Saddles
6 Flat Pan-Post Standoffs for use with 0.75 

T

AK

-T

Y

Cable Ties

1

100

Panduit-Pannet-html.html
background image

147

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

N

ET

M

ANAGER

Horizontal Cable Managers

• Removable front cover hinges 180° up or down
• Built-in cable retainers
• Integral bend radius control throughout all cable pathways

• Pass through holes allow front to rear cabling
• Mounts to 19” EIA rack or cabinet

NCMH2

^One rack space = 44.45mm
All product colour is black.

NCMHF1

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

NetManager Panels

NCMHF1

Horizontal cable manager, front only, 38mm x 76.2mm.
Total width 482.6mm

1

1

NCMHF2

Horizontal cable manager, front only, 76.2mm x 76.2mm.
Total width 482.6mm

2

1

NCMH2

Horizontal cable manager, front, 76.2mm x 76.2mm, rear
50.8mm x 127mm. Snap-on rear cover.

2

1

Replacement Covers 

NCMH1-RFC Replacement front cover for 1RU horizontal cable manager.

1

1

10

NCMH2-RFC Replacement front cover for 2RU horizontal cable manager.

2

1

10

Panduit-Pannet-html.html
background image

148

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

WMP1E

WMPH2E

WMPFSE

WMPLFSE

WMPHF2E

P

ATCH

L

INK

Horizontal Cable Managers

• Patented dual hinged cover allows cable access without

removing cover

• Pass through holes allow front to rear cabling
• Flexible front fingers allow easy moves, adds and changes

of patch cords

• Flexible rear fingers allows access for cable termination of

patch panel

• Rear pathway allows cable routing around rack channels

into vertical cable management

• Mounts to 19” EIA standard rack or cabinet

O2 Rack Space Panels: 72 Category 5e, 24 AWG, 4 pair UTP cables per side

WMPSE

Part Number

Part Description

No. of

Rack

Spaces

Std.

Pkg.

Qty.

19” Manager, Front and Rear, 1 RU

WMPLSE

Includes 38.1mm x 76.2mm front, 25.4mm x 127mm rear duct
and mounting screws. Total width 19" (482.6mm).

1

1

WMPSE

One rack space horizontal cable manager, duct and cover;
38.1mm x 76.2mm on front and 25.4mm x 101.6mm on rear.
Includes 2 strain relief clips and mounting screws.

1

1

19” Manager, Front and Rear, 2 RU

WMP1E

Includes 76.2mm x 76.2mm front and 50.8mm x 127mm rear
duct with cover. Includes 2 strain relief clips and mounting
screws.

2

1

WMPH2E

Includes 76.2mm x 76.2mm duct on front, 50.8mm x 127mm
duct on rear, 2 bend radius control clips, 2 strain relief clips,
mounting screws, wire retainers and front and rear covers. Total
width 512.7mm

2

1

19” Manager, Front Only, 1 RU

WMPFSE

One rack space horizontal cable manager, duct and cover,
38.1mm x 76.2mm on front only. Includes mounting screws.

1

1

WMPLFSE

Includes 38.1mm x 76.2mm front duct and mounting screws.
Total width 482.6mm.

1

1

19” Manager, Front Only, 2 RU

WMPF1E

Two rack space horizontal cable manager, duct and cover,
88.9mm x 81.5mm on front only. Includes 3 wire retainers and
mounting screws.

2

1

WMPHF2E

Includes 76.2mm x 76.2mm duct on front, 2 bend radius control
clips, mounting screws, 3 wire retainers and front cover. Total
width 512.7mm

2

1

Panduit-Pannet-html.html
background image

149

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

CMPH2W

CMPH2

CMPHF1

CMPHHF1

CMPHF2

CMPHH2

CMPH123

CMPH223

CMPHF123

CMPHF223

O

PEN

-A

CCESS

Cable Management

• Unique snap on D-rings for complete flexibility
• Mounts to standard EIA standard 19” or 23” racks and cabi-

nets

• Pass through holes allow front to rear cabling

• Patented cable manager ring
• Optional snap-on cover
• Flexible material allows D-ring arm to rotate allowing entire

cable bundle to be inserted and removed

^One rack space = 44.45mm
All product colour is black.
See horizontal D-rings for cable capacities (page XXX).

CMPH1W

CMPH1

Part Number

Part Description

No. of

Rack

Spaces^

Std.
Pkg.
Qty.

19” Manager, Front and Rear, 1RU

CMPH1W

Includes pre-assembled D-rings on front and rear with cover.
Front D-ring size 38mm x 76mm
Read D-ring size 38mm x 127mm

1

1

CMPH1

Includes pre-assembled D-rings on front and rear.
Front D-ring size 38mm x 76mm
Read D-ring size 38mm x 127mm

1

1

19” Manager, Front and Rear, 2RU

CMPH2W

Includes pre-assembled D-rings on front and rear, cover and
bend radius control clips.
Front D-ring size 76mm x 76mm
Read D-ring size 76mm x 76mm

2

1

CMPH2

Includes pre-assembled D-rings on front and rear.
Front D-ring size 76mm x 76mm
Read D-ring size 76mm x 127mm

2

1

19” Manager, Front Only, 1RU

CMPHF1

Includes pre-assembled D-rings on front.
Front D-ring size 38mm x 76mm.

1

1

CMPHHF1

Includes pre-assembled D-rings on front only.
Front D-ring size 38mm x 127mm

1

1

19” Manager, Front Only, 2RU

CMPHF2

Includes pre-assembled D-rings on front.
Front D-ring size 76mm x 76mm.

2

1

CMPHH2

Includes pre-assembled D-rings on front
Front D-ring size 76mm x 127mm

2

1

Optional Covers

CMPH1C

Replacement cover for 1 RU D-ring panels.
Total width 19.5” (495mm)

1

1

CMPH2C

Replacement cover for 2 RU D-ring panels.
Total width 19.5” (495mm)

2

1

23” Manager, Front and Rear

CMPH123

Includes pre-assembled D-rings on front and rear.
Front D-ring size 38mm x 76mm
Read D-ring size 38mm x 127mm

1

1

CMPH223

Horizontal panel - D-rings front and rear.

2

1

23” Manager, Front Only

CMPHF123

Includes pre-assembled D-rings on front.
Front D-ring size 38mm x 76mm.

1

1

CMPHF223

Includes pre-assembled D-rings on front.
Front D-ring size 76mm x 76mm.

2

1

Panduit-Pannet-html.html
background image

150

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

O

PEN

-A

CCESS

Horizontal D-rings

• Patented cable manager ring
• D-rings are designed to snap into 

O

PEN

-A

CCESS

panels only

• Flexible material allows arm to rotate so entire cable bun-

dle can be inserted and removed

All product colour is black.

All product colour is black.

CMDRH1

CMDRHD1

CMDRHD2

CMDRH2

Vertical D-rings

• Patented Cable Manager Ring
• Standard EIA hole spacing allows product to be mounted to

any standard rack

• Flexible material allows arm to rotate 90° so entire cable

bundle can be inserted and removed

• Rounded edges prevent damage to cable insulation
• 6mm mounting hole allows for a variety of screws to secure

the D-ring to a surface

• Creates a structured pathway and allows for open access

CMVDR1

CMVDR1S

CMVDR2

CMVDR2S

CMVDRC

Part Number

Part Description

Cable Capacity

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

UTP

(.187) 

ScTP

(.250) 

Fibre

(3mm) 

CMDRH1

Horizontal D-ring
Outside dimensions 38mm x 76mm

40

24

100

1

10

CMDRHD1

Horizontal High Capacity D-ring
Outside dimensions 38mm x 127mm

52

32

132

1

10

CMDRH2

Horizontal D-ring
Outside dimensions 76mm x 76mm

96

48

252

1

10

CMDRHD2

Horizontal D-ring
Outside dimensions 76mm x 127mm

192

96

504

1

10

Part Number

Part Description

Cable Capacity

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

UTP

(.187) 

ScTP

(.250) 

Fibre

(3mm) 

CMVDR1

Vertical D-ring
Outside dimensions 145mm L x 52mm W

96

48

252

1

10

CMVDR1S

Vertical D-ring
Outside dimensions 82mm L x 52mm W

52

32

132

1

10

CMVDR2

Vertical D-ring
Outside dimensions 145mm L x 83mm W

192

96

504

1

10

CMVDR2S

Vertical D-ring
Outside dimensions 625mm L x 75mm W

96

48

252

1

10

CMVDRC

Centre mounted vertical D-ring for routing
cables between two adjacent racks.
(Requires 8.25 spacing between the centre
lines of the adjacent rack’s mounting holes).
Outside dimensions 143mm L x 222mm W

400

200

1000

1

10

Panduit-Pannet-html.html
background image

151

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Active Equipment Cable Managers

• Options for use with active equipment that have cards

(blades) oriented horizontally or vertically

• Integral bend radius control supports patch cables as they

go to and from cards

• CMBRC5/5E patented bend radius control clip
• Finger spacing helps keep patch cables aligned with cards
• Mounts to EIA standard rack or cabinet

CMBRC5

CMBRC5E

NCMHAEF4

^One rack space = 44.45mm
All product colour is black.

Bend Radius Control Accessories

• Enhances cable management on racks and cabinets

WMSRC1

WMSRC2

Bundle Retainers

• Bundle retainer supports cable in vertical or 

horizontal configurations

• Spring fingers with large lead-in facilitates insertion of 

cable bundles

• The BR.5 and BR.75 can be joined together to allow for

wire breakouts

BR2-1.3  

All product colour is black.

All product colour is black.

CMBRC1

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

BR2-1.3

Bundle Retainer. Standard EIA hole spacing for mounting. Maximum
bundle capacity: 50.8mm.

1

10

BR2-1.3-A

Bundle Retainer. Adhesive base and standard EIA hole spacing
provides mounting options. Maximum bundle capacity: 50.8mm.

1

10

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Bend Radius Control Clips

CMBRC1

1 RU cable management bend radius clip kit.

1

10

CMBRC1E

1 RU extended cable management bend radius control clip kit.

1

10

CMSRC2

Provides cable bend radius control and facilitates patch cable routing to
and from horizontal cable management panels. Mounts directly to 19”
or 23” EIA standard communication racks or 
cabinets (2 RU).

1

10

Strain Relief Clips

WMSRC1

Strain relief clip, 25.4mm. Mounts to rear of rack adjacent to 
horizontal panels

1

10

WMSRC2

Strain relief clip, 50.8mm. Mounts to rear of rack adjacent to 
horizontal panels.

1

10

Part Number

Part Description

No. of

Rack

Spaces^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Vertical Managers for Horizontal Patching

CMBRC5

Cable management bend radius clip. Dimensions
222.25mm H x 83.8mm D x 26.2mm W Capacity: 24
cables (4.75mm Dia) per rack space

5

1

10

CMBRC5E

Cable management bend radius clip. Dimensions
222.25mm H x 127.0mm D x 26.2mm W Capacity: 48
cables (4.75mm Dia) per rack space

5

1

10

Horizontal Manager with Hinged Cover for Vertical Patching

NCMHAEF2

Horizontal active equipment manager for vertical cards
(blades). Dimensions 88.99mm H x 204.3mm D x
488.9mm W

2

1

NCMHAEF4

Horizontal active equipment manager for vertical cards
(blades). Dimensions 176.9mm H x 204.3mm D x
488.9mm W

4

1

Panduit-Pannet-html.html
background image

152

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Waterfall Accessories

• Product available as a kit (includes base, 2 wings and

cable ties) or purchased separately

• Easy to install waterfall kit maintains bend radius control in

both vertical and horizontal directions to provide a 
TIA/EIA-568-B compliant installation

• Base attaches to either the rung or stringer on most 

standard ladder racks for a variety of 
installations/configurations

• Modular components allow user to custom configure each

location where cable management is required

CMW-KIT

CMWB

CMWW

Stackable Cable Rack Spacers

• Separate and support cable and prevent pinch points

between the bottom row of cable and the rung as a 
result of the weight of multiple cable layers applied 
on top of each other

• Maximise rack space by stacking products for maximum

cable capacity

• Provide an alternative to lacing cord by allowing user to

secure cable to spacer to prevent movement of cable

• Provide attractive installations
• Mounts to ladder rack with standard cross section 

cable ties

CRS6-X

CRS1-X

CRS4-125-X

CRS1-125-X

For white, include suffix of 10. For example: CMW-KIT10

All product colour is black.

Part Number

Part Description

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CMW-KIT

Cable management waterfall kit. Includes CMWB, 2 CMWW
and cable ties.

Black

1

10

CMWB

Cable management waterfall base. Used to maintain
44.45mm bend radius control vertically when transferring
cable off of ladder rack. Mounts to ladder rack rung or
stringer with standard cross section cable ties (included).

Black

1

10

CMWW

Cable management waterfall wing. Used in conjunction wit
hCMWB to maintain 25.4mm bend radius control horizontally
when transferring cable off ladder rack.

Black

1

10

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Stackable Cable Rack Spacers 0.8 OD Cable

CRS6-X

Six space Stackable Cable Rack Spacer. Accepts cable up to 0.8
diameter.

10

100

CRS1-X

One space Stackable Cable Rack Spacer. Use with CRS6 to fill width
of ladder rack. Accepts cable up to 0.8 diameter.

10

100

Stackable Cable Rack Spacers 1.25 OD Cable

CRS4-125-X

Four space Stackable Cable Rack Spacer. Accepts cable up to 1.25
diameter.

10

100

CRS1-125-X

One space Stackable Cable Rack Spacer. Use with CRS4 to fill width
of ladder rack. Accepts cable up to 1.25 diameter.

10

100

Panduit-Pannet-html.html
background image

153

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Flat 

P

AN

-P

OST

Standoff

• Standard EIA hold spacing allows product to be mounted

with user supplied screws up to 6mm diameter

• Organise cables in standard cabinets and racks

• Use where space is limited

PPF2SV-S25-V

PPF2SV-S25-V69

PPF2S-S25-V

PPF2S-S25-V69

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Flat Pan-Post Standoff for 

T

AK

-T

Y

Hook and Loop Cable Ties

PPF2SV-S25-V

Nylon 6.6 Flat Pan-Post Standoff. Use with 

T

AK

-T

Y

Hook and

Loop Cable Ties

5

100

PPF2SV-S25-V69

Flame Retardant Nylon 6.6 Pan-Post Standoff. Use with 

T

AK

-T

Y

Hook & Loop Cable Ties. Material meets UL94V-0 specifications

5

100

Flat Pan-Post Standoff for Nylon Cable Ties

PPF2S-S25-V

Nylon 6.6 Flat Pan-Post Standoff. Use with miniature, intermediate
and standard cross section cable ties.

5

100

PPF2S-S25-V69

Flame Retardant Nylon 6.6 Flat Use with miniature, intermediate
and standard cross section cable ties. Material meets UL94V-0
specifications

5

100

Panduit-Pannet-html.html
background image

154

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

O

PTICOM

HD Cross Connect System Roadmap

Footprint for 

O

PTICOM

HD Rack, Slack Manager and End Panel

Front view

Rear view

Single Rack with

End Cap

Panduit-Pannet-html.html
background image

155

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

TRENBSW2384 

— 

23" Seismic 

Telecommunication Rack (page157)

HDFE288SC or HDFE288LC 

(pre-loaded with connectors)

HDFE18FAP or HDFE18FAPBL

(Modular) — 228.6mm Rack Mount
Fibre Enclosure (page 158)

TREC24L, TREC24R —
Telecommunications Rack End Cap
(page 157)

HDFE144SC or HDFE144LC 
(pre-loaded with connectors)
HDFE9FAPBL or HDFE9FAP (Modular)
— 3 RU Rack Mount Fibre Enclosure-
For top rack location only (page 158)

1

4

2

3

4

1

2

3

O

PTICOM

HD Cross Connect System Roadmap

• High density fibre distribution system for use in multi-rack line ups providing horizontal pathways from rack to rack. 

Ideal for multi-rack applications with up to 1584 fibre terminations per rack

Panduit-Pannet-html.html
background image

156

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

O

PTICOM

HD Inter-Connect System Roadmap

TRENBS2384 (Shown), TRENBS1984 –
Telecommunications Rack (page 157)

HDFE288SC or HDFE288LC 
(pre-loaded with connectors)
HDFE18FAP or HDFE18FAPBL
(Modular) – 228.6mm Rack Mount
Fibre Enclosure (page 158)

TREC –  Telecommunications Rack End
Cap (page 157)

HDFE144SC or HDFE144LC 
(pre-loaded with connectors)
HDFE9FAPBL or HDFE9FAP (Modular) 
– 3 RU Rack Mount Fibre Enclosure
(page 158)

TRVSM6 – 152.40mm Wide Vertical
Slack Manager 

1

4

2

3

5

4

1

2

5

3

6

• High density fibre distribution system with optimized bend radius control, and provisions for vertical slack management

TRT23LF, TRT19LF – Lower front only
trough (page 157)

6

Panduit-Pannet-html.html
background image

157

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

O

PTICOM

HD Fibre Distribution Equipment Racks and Accessories

• Rack and cable management system for high density 

fibre distribution

• System offerings include Zone 4 Seismic, NEBS and 

GR-449 Issue 2 compliance

• TRENB racks meet EIA-310-D (except inside clearance)

• Cross-connect routing system accommodates up to1,584

2mm dia fibre patch cords per rack 

• Inter-connect routing system accommodates up to 1,584

2mm dia fibre patch cords per rack

^ One rack space = 1.75in. (44.45mm) Capacities based on Telcordia GR-447-CORE 50% fill calculation.
Fill capacity of Lower and Mezzanine Troughs = 616 (front) 522 rear  (3mm Jacketed Fibres).
Fill capacity of Front Only Lower and Mezzanine Troughs = 616 (3mm Jacketed Fibres).
Fill capacity of Rear Trough = 252 (3mm Jacketed Fibres).

Part Number

Part Description

No. of

Rack

Spaces

^

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

O

PTICOM

HD Cross

-

Connect Fibre Distribution System

TRENBSW2384

23" WECO Enhanced Network Bay Seismic
Telecommunication Rack. GR 449 Issue 2 and NEBS
compliant. 247.65mmD x 660.4mmW x 2133.6mmH

44

1

TRENBW2384

23" WECO Enhanced Network Bay Telecommunication
Rack, Zone 4 Seismic.
247.65mmD x 660.4mmW x 2133.6mmH

44

1

HDFDF2384W

6 level rear trough fibre routing system for multi-rack
line-ups. Kit includes all components for one 23"
WECO rack. GR 449 Issue 2 and NEBS compliant.

1

TREC24L

Telecommunication rack left end cap. Mounts to end of
rack line-up. Enclosed area can be used for routing
power, voice or data lines. GR 449 Issue 2 and NEBS
compliant. 609.6mmD x 68.5mmW x 2133.6mmH

1

TREC24R

Telecommunication rack right end cap. Mounts to end
of rack line-up. Enclosed area can be used for routing
power, voice or data lines. GR 449 Issue 2 and NEBS
compliant. 609.6mmD x 68.5mmW x 2133.6mmH

1

O

PTICOM

HD Inter

-

Connect Fibre Distribution System

TRENBS1984

19" EIA Enhanced Network Bay Zone 4 Seismic 
Telecommunication Rack.  
247.65mmD x 660.4mmW x 2133.6mmH

44

1

TRENBS2384

23" EIA Enhanced Network Bay Zone 4 Seismic
Telecommunication Rack. 
247.65mmD x 660.4mmW x 2133.6mmH

44

1

TRVSM4

Telecommunication rack interbay vertical slack manager.
Includes lower guard box and vertical D-Rings for rear
cable management. 76.3mm spools on front provide
3801mm bend radius control when slacking fibre jumpers.
457.2mmD x 101.6mmW x 2133.6mmH

1

TRT19LF

Cable routing trough used for routing cables between
19" racks.

5

1

TRT23LF

Cable routing trough used for routing cables between
23" racks.

5

1

TREC

Telecommunication rack end cap. Mounts to end of rack
line-up. Enclosed area can be used for routing power, voice
or data lines. 457.2mmD x 101.6mmW x 2133.6mmH

1

TRRG236

Telecommunication rack 152.4mm deep rear guard box
for 23" racks. Used to extend rear profile of 23" rack to
match end panel and vertical slack manager. 

1

O

PTICOM

HD Accessories 

TRAKS

Seismic Telecommunication Equipment Rack Anchor Kit

1

10

TRTA19

Telecommunication rack top angle for 19" rack.

1

TRTA23

Telecommunication rack top angle for 23" rack.

1

TRFG19

Telecommunication rack front bottom guard rail for 19"
rack. Used to extend the front surface of rack to match
vertical slack manager and lower trough projection.

1

TRFG23

Telecommunication rack front bottom guard rail for 23"
rack. Used to extend the front surface of rack to match
vertical slack manager and lower trough projection.

1

TRENBS2384

TREC

TRT19LF

TRENBS1984

Panduit-Pannet-html.html
background image

158

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

O

PTICOM

HD Fibre Distribution Enclosures, Splice Trays and Holders

• Complies with GR-449 Issue 2 and NEBS 

(including GR-1089 and GR-63-Seismic Zone 4)

• Includes fibre optic cable routing kits (grommets, cable ties,

saddle clips, spools, strain relief and ID/caution labels for
various cable management solutions

• Patented fanning guides with retainer strips protect cables

as they transition into the vertical channel while
maintaining a 38.1mm bend radius

• Fully retractable top cover and removable front covers

provide easy access to connectors 

• Can be mounted to any standard EIA/WECO 19" or 23"

rack or cabinet 

• Removable connector mounting plate for increased 

cabling access

^ One rack space = 44.45mm

HDFE9FAPBL

HDFE18FAPBL

HDFE9FAP

HDFE288LC

FST24S

FSTHDH9

HDCRT

Part Number

Part Description

Colour

No. of

Rack

Spaces^

Std.

Pkg.

Qty

O

PTICOM

HD

Rack Mount Fibre Optic Enclosures

HDFE9FAPBL

Holds up to 9 FMP or FAP panels. 
133.4mmH x 419.1mmW x 444.5mmD

Black

3

1

HDFE18FAPBL

Holds up to 18 FMP or FAP panels. 
228.6mmH x 419.1mmW x 444.5mmD

Black

6

1

HDFE9FAP

Holds up to 9 FMP or FAP panels. 
133.4mmH x 419.1mmW x 444.5mmD

Off

White

3

1

HDFE18FAP

Holds up to 18 FMP or FAP panels. 
228.6mmH x 419.1mmW x 444.5mm

Off

White

6

1

HDFE144LC

Loaded with 144 LC singlemode simplex adapters.
PANDUIT

part number FASJLCZBU.

133.4mmH x 419.1mmW x 444.5mmD

Off

White

3

1

HDFE288LC

Loaded with 288 LC singlemode simplex adapters.
PANDUIT

part number FASJLCZBU. 

228.6mmH x 419.1mmW x 444.5mmD

Off

White

6

1

HDFE144SC

Loaded with 144 SC singlemode simplex adapters. 
Holds up to 9 FMP or FAP panels. 
133.4mmH x 419.1mmW x 444.5mmD

Off

White

3

1

HDFE288SC

Loaded with 288 SC singlemode simplex adapters.
PANDUIT

part number FASSCZBU.

228.6mmH x 419.1mmW x 444.5mmD

Off

White

6

1

HDFE108ST

Loaded with 108 ST singlemode simplex adapters.
PANDUIT

part number CMSTZBU. 

133.4mmH x 419.1mmW x 444.5mmD

Off

White

3

1

HDFE216ST

Loaded with 216 ST singlemode simplex adapters.
PANDUIT

part number CMSTZBU. 

228.6mmH x 419.1mmW x 444.5mmD

Off

White

6

1

O

PTICOM

HD

Splice Trays and Holders

FSTHDH9BL

Holds and secures up to 9 FST24S splice trays. Installs
in place of existing back door of HDFE18FAPBL.

Black

1

FSTHDH9

Holds and secures up to 9 FST24S splice trays.
Installs in place of existing back door of HDFE18FAP.

Off

White

1

FSTHED

Holds and secures up to 4 FST24S splice trays with
built in fibre spooling. Mounting hardware included.
Splice trays held in place with 

PANDUIT

T

AK

-T

Y

Cable Ties. For use with FMT1, FMT2, FMD1, FMD2,
FRME3, FRME4 and all 3RU 

O

PTICOM

HD

Enclosures. 44.5mmH x 330.2mmW x 177.8mmD

Off

White

1

FST24S

Accommodates up to 24 mechanical or fusion splices.
For use with FSTHDH9(BL) or FSTHED.
9.4mmH x 266.7mmW x 116.84mmD

Off

White

1

O

PTICOM

HD

Connector Removal Tool

HDCRT

Tool provides additional means for inserting and
removing connectors to minimize adjacent connector
disturbance. Comes with swappable jaws for LC
(simplex and duplex) and SC (simplex) connectivity,
LED light for working in dark areas and a carrying
case for storage and transportation.

1

Panduit-Pannet-html.html
background image

159

For AWG to mm

2

conversion tables see page 192 - 194

G

ROUNDING

& B

ONDING

The industry’s most reliable line of connectors.

PANDUIT

pioneered the testing of copper

compression connectors by Telcordia to the Network Equipment Building Systems (NEBS) Level 3

requirements. Level 3 is the most stringent level of the NEBS performance criteria.

Compression connectors tested by Telcordia and meet

NEBS Level 3

All  

PANDUIT

connectors have been designed for easy

installation and for maximum durability

A broad variety of mechanical, pipe, rod and tap 

ground connectors are available to meet network
grounding applications

PANDUIT

offers a variety of copper compression taps

for grounding needs: extruded heavy wall “Type C”
CTAPS, Stamped and Formed “Type F” CTAPS, and
extruded “Type H” HTAPS, all in a wide range of run/tap
conductor combinations

P

AN

-T

ERM

Ring Terminals are available in nylon, vinyl

and non-insulated versions and can be used in a vari-
ety of power and grounding applications

Crimping tools enable fast and proper product installa-

tion at a lower installed cost

Telcordia testing of copper compression connectors to NEBS Level 3 Criteria provides assurance these

products will meet or exceed installation requirements.Telcordia serves as the testing agency for the

Telecommunication Industry. Telcordia's evaluation represents an objective third party analysis of

copper compression connector, features function and performance. This confirms compliance of

PANDUIT

grounding products with globally recognised criteria.

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

160

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see page 192 - 194

Grounding & Bonding System Roadmap

Building
Network
Ground

Vertical
Equalizer

Main Building
Grounding Bus Bar

PGK96 Kit
PGKE96 Kit
(see page E8

)

Modular
Patch
Panel

Equipment

1

2

3

7

*

4

8

*

9

*

6

10

*

7

*

8

*

9

*

7

8

*

9

*

6

Equipment

Panduit-Pannet-html.html
background image

161

For AWG to mm

2

conversion tables see page 192 - 194

TRGB231 Rack Ground Bar –
Rack Mount (page 162)

TRGB19 Rack round Bar –                
Channel Mount (page 162)

Two Hole, Long Barrel Lugs with Inspection
Window (pages 169-178)

Compression Connectors Taps
(page 181)

Clear Covers (page 181)

TRGK672 Rack Ground Kit 
(page 162)

TRGKJ1024 Rack Ground Kit
(page 162)

TRGKJ4120 Rack Ground Kit
(page 162)

TRGKE696 Rack Ground Kit 
(page 162)

Insulated & Non-Insulated Ring Terminals
(pages 190-191)

3

7

*

1

2

Telecommunications rack

N

ET

F

RAME

rack

* Included in a kit

1

2

3

4

5

6

7

8

9

10

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

162

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see pages 192-194

Telecommunication Rack Grounding Products

• Provides protection for active equipment against stray electrical emissions

TRGB19

TRGB231

*Also mounts to standard EIA racks and 

N

ET

F

RAME

racks.

TRGK672

TRGB23

TRGKJ1024

TRGKJ4120

TRGKE696

Grounding Kit

• Grounds modules to another ground wire in shielded applications

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

CJSGK-X

Kit used to ground 

Giga-TX

Style Jack Modules to another ground

wire in shielded applications.

10

100

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

TRGB19

Ground Bar, 279.4mm long, mounts to the top channel of the 19"
Telecommunication Equipment Rack and is used as a grounding bus.
Tinned copper, #6-32 and 1/4-20 threaded screw holes.  
Includes hardware.

1

10

TRGB23

Ground Bar, 381mm long, mounts to the top of the 23"
Telecommunication Equipment Rack and is used as a grounding bus.
Tinned copper, #6-32 and 1/4-20 threaded screw holes.  
Includes hardware.

1

10

TRGB191*

Ground Bar, 432.6mm long, 1 RU, mounts to vertical channels of the
19” Telecommunication Equipment Rack and is used as a grounding
bus.  Tinned copper, #6-32 and 1/4-20 threaded screw holes.  
Includes hardware.

1

10

TRGB231*

Ground Bar, 584.2mm long, 1 RU, mounts to vertical channels of the
Telecommunication Equipment Rack and is used as a grounding bus.
Tinned copper, #6-32 and 1/4-20 threaded screw holes.  
Includes hardware.

1

0

TRGK672*

Ground kit used to ground individual rack to building network ground. 
#6 AWG insulated stranded copper 1828.8mm long. Includes external
lock washers, 1/4-20 screws, H-TAP, black cover and anti-oxidizing
paste. Accomodates building network ground wire from #1/0-#6 AWG.

1

10

TRGKE696

Ground kit mounts to vertical channel of the rack and is used as a
connection between equipment jumpers and rack ground bar. #6
tinned solid copper wire 2438.4mm long. Includes #12-24 screws, 
cable clamps,1/4-20 screws, external lock washers and 
anti-oxidizing paste.

1

10

TRGKJ1024

Equipment ground jumper kit used to ground equipment to
TRGKE696. #10 AWG insulated stranded copper 609.6mm long.  
Includes H-TAP, black cover and anti-oxidizing paste.

1

10

TRGKJ4120

Equipment ground jumper kit used to ground equipment to the
building network ground, TRGKE696, or directly to the rack. Cable is
#4 AWG insulated stranded copper 3048mm long. Includes #12-24
screws, cable clamps, HTAP, black cover and anti-oxidizing paste.
Accommodates building network ground wire from #1/0-#6 AWG.

1

10

Panduit-Pannet-html.html
background image

163

For AWG to mm

2

conversion tables see pages 192-194

Part Number System For Compression Connectors

H = 45° Angle
F = 90° Angle
No Letter = Straight

1 = 1
2 = 2
3 = 3
5 = 5
6 = 6
X = 10
E = 20
Q = 25
L =  50

A

=

15.88mm

B =

19.05mm

C =

22.2mm

D =

25.4mm

E =

31.75mm

No Letter = 31.75mm
AD = 15.9mm to 25.4mm
(Slotted)

10 =  #10
14 =  6.35mm
56 =  7.95mm
38 =  9.54mm
12 =  12.7mm
58 =  15.9mm
34 =  19.05mm
00 =  Blank Tongue

LCD

2/0

38

D

X

Part Designation

Conductor

Size

Bolt Hole Size

Designation

2 Bolt

Hole Spacing *

Tongue Angle

Std. Pkg.

Size

*

LCA, LCC and LCD Styles Only

Ex: LCD Lug, Copper Two Hole Standard Barrel

For Use With Copper Cables Only

*UL Listed and CSA Certified with code, locomotive and class K & M weld cables.
‡Contact

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

Type LCA

Copper Lugs 

One-Hole Lug Standard Barrel

INSPECTION

WINDOW

A

W

LCA products continued 

on next page

• Colour coded to show proper die number and colour
• Tested by Telcordia and meets NEBS level 3

• UL Listed per 486A up to 35KV**
• Inspection window to visually assure full cable insertion

Part Number

Copper Conductor

Size

*

Die Colour

& No. 

Bolt Hole

Size

Length (A) Width (W)

Std.

Pkq.

Qty.

mm

mm

mm

LCA10-10-L

#14 – #10 AWG STR, 

#12 – #10 AWG SOL

4.83

27.2

9.7

50

LCA10-14-L

6.35

29.4

10.7

50

LCA10-56-L

7.92

32.5

13.7

50

LCA10-38-L

9.53

35.1

14.2

50

LCA8-10-L

#8 AWG

Red P21

4.83

31.75

10.4

50

LCA8-14-L

6.35

34.04

12.2

50

LCA8-56-L

7.92

37.08

14.2

50

LCA8-38-L

9.53

39.62

15.2

50

LCA6-10-L

#6 AWG

Blue P24

4.83

38.61

11.4

50

LCA6-14-L

6.35

40.89

12.2

50

LCA6-56-L

7.92

43.94

14.2

50

LCA6-38-L

9.53

46.48

15.7

50

LCA4-10-L

#4 – #3 AWG STR,

#2 AWG SOL

Grey P29

4.83

39.1

14

50

LCA4-14-L

6.35

41.4

14

50

LCA4-56-L

7.92

44.4

14

50

LCA4-38-L

9.53

47.0

15.7

50

LCA2-14-Q

#2 AWG

Brown P33

6.35

45.0

15.2

25

LCA2-56-Q

7.92

48.3

16.8

25

LCA2-38-Q

9.53

50.0

16.8

25

LCA2-12-Q

12.7

56.1

19

25

LCA1-14-E

#1 AWG

Green P37

6.35

45.5

17.8

20

LCA1-56-E

7.92

48.8

17.8

20

LCA1-38-E

9.53

50.5

17.8

20

LCA1-12-E

12.7

56.4

20

20

LCA1/0-14-X

1/0 AWG

Pink P42

6.35

49.5

19.3

10

LCA1/0-56-X

7.92

50.8

19.3

10

LCA1/0-38-X

9.53

52.8

19.3

10

LCA1/0-12-X

12.7

58.7

20.3

10

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

164

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see pages 192-194

For Use With Copper Cables Only

Type LCA

*UL Listed and CSA Certified with code, locomotive and class K & M weld cables.
‡Contact

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

Copper Lugs 

One-Hole Lug Standard Barrel (continued)

INSPECTION

WINDOW

A

W

mm

mm

mm

Std.

Pkq.

Qty.

Width (W)

Length (A)

Bolt Hole

Size

Die Colour

& No. 

Copper Conductor

Size

*

Part Number

LCA2/0-14-X

2/0 AWG

Black P45

6.35

53.1

21.6

10

LCA2/0-56-X

7.92

53.1

21.6

10

LCA2/0-38-X

9.53

54.6

21.6

10

LCA2/0-12-X

12.7

61.0

21.6

10

LCA3/0-14-X

3/0 AWG

Orange P50

6.35

57.9

24.4

10

LCA3/0-56-X

7.92

57.9

24.4

10

LCA3/0-38-X

9.53

59.4

24.4

10

LCA3/0-12-X

12.7

65.8

24.4

10

LCA4/0-14-X

4/0 AWG

Purple P54

6.35

59.9

26.9

10

LCA4/0-56-X

7.92

60.5

26.9

10

LCA4/0-38-X

9.53

62.2

26.9

10

LCA4/0-12-X

12.7

68.1

26.9

10

LCA250-14-X

250 kcmil

Yellow P62

6.35

62.7

29.7

10

LCA250-56-X

7.92

63.0

29.7

10

LCA250-38-X

9.53

64.8

29.7

10

LCA250-12-X

12.7

70.6

29.7

10

LCA300-56-X

300 kcmil

White P66

7.92

74.7

30.2

10

LCA300-38-X

9.53

74.7

30.2

10

LCA300-12-X

12.7

77.5

30.2

10

LCA300-58-X

15.88

82.8

30.2

10

LCA300-78-X

22.22

94.0

30.2

10

LCA350-38-X

350 kcmil

Red P71

9.53

75.7

32.5

10

LCA350-12-X

12.7

78.5

32.5

10

LCA350-58-X

15.9

83.8

32.5

10

LCA350-78-X

22.22

95.0

32.5

10

LCA400-38-6

400 kcmil

Blue P76

9.53

81.8

35.3

6

LCA400-12-6

12.7

81.8

35.3

6

LCA400-58-6

15.88

87.1

35.3

6

LCA400-78-6

22.22

92.0

35.3

6

LCA500-38-6

500 kcmil

Brown P87

9.53

86.1

39.1

6

LCA500-12-6

12.7

90.2

39.1

6

LCA500-58-6

15.88

95.5

39.1

6

LCA500-34-6

19.05

99.1

39.1

6

LCA500-78-6

22.2

105.4

39.1

6

LCA500-1-6

25.4

108.5

39.1

6

LCA600-12-6

600 kcmil

Green P94

12.7

106.7

43.2

6

LCA600-58-6

15.88

106.7

43.2

6

LCA600-78-6

22.22

106.7

43.2

6

Panduit-Pannet-html.html
background image

165

For AWG to mm

2

conversion tables see pages 192-194

For Use With Copper Cables Only

Type LCA-H

*UL Listed with code, locomotive and class K & M weld cables.
‡Contact

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

INSPECTION

WINDOW

W

45   5˚

+

_

A

Copper Lugs 

One-Hole Lug Standard Barrel, 45

°

Angle Tongue

• Colour coded to show proper die number and colour
• Tested by Telcordia and meets NEBS level 3  

• UL Listed per 486A up to 35KV**
• Inspection window to visually assure full cable insertion

LCA-H product listing continued on the following page

Part Number

Copper Conductor

Size*

Die Colour 

& No.

Bolt Hole

Size

Length (A) Width (W)

Std.

Pkg.

Qty.

mm

mm

mm

LCA10-14H-L

#14—#10 AWG STR,

#12–#10 AWG SOL

6.35

26.7

10.7

50

LCA8-10H-L

#8 AWG

Red P21

4.83

27.9

10.4

50

LCA8-14H-L

6.35

30.2

12.2

50

LCA8-56H-L

7.92

33.0

14.2

50

LCA8-38H-L

9.53

35.6

15.2

50

LCA6-10H-L

#6 AWG

Blue P24

4.83

32.8

11.4

50

LCA6-14H-L

6.35

35.1

11.4

50

LCA6-56H-L

7.92

37.8

14.2

50

LCA6-38H-L

9.53

40.4

15.7

50

LCA4-10H-L

#4 – #3 AWG STR,

#2 AWG SOL

Grey P29

4.83

33.3

14.0

50

LCA4-14H-L

6.35

35.6

14.0

50

LCA4-56H-L

7.92

38.6

14.0

50

LCA4-38H-L

9.53

40.9

15.7

50

LCA2-14H-Q

#2 AWG

Brown P33

6.35

37.8

15.2

25

LCA2-56H-Q

7.92

40.9

16.8

25

LCA2-38H-Q

9.53

42.7

16.8

25

LCA2-12H-Q

12.7

48.3

19.0

25

LCA1-14H-E

#1 AWG

Green P37

6.35

38.1

17.8

20

LCA1-56H-E

7.92

41.1

17.8

20

LCA1-38H-E

9.53

43.2

17.8

20

LCA1-12H-E

12.7

49

19.0

20

LCA1/0-14H-X

1/0 AWG

Pink P42

6.35

41.4

19.3

10

LCA1/0-56H-X

7.92

42.9

19.3

10

LCA1/0-38H-X

9.53

44.7

19.3

10

LCA1/0-12H-X

12.7

50.8

20.3

10

LCA2/0-14H-X

2/0 AWG

Black P45

6.35

45

21.6

10

LCA2/0-56H-X

7.92

45

21.6

10

LCA2/0-38H-X

9.53

46.5

21.6

10

LCA2/0-12H-X

12.7

52.8

21.6

10

LCA3/0-14H-X

3/0 AWG

Orange P50

6.35

48.3

24.4

10

LCA3/0-56H-X

7.92

48.3

24.4

10

LCA3/0-38H-X

9.53

49.8

24.4

10

LCA3/0-12H-X

12.7

56.1

24.4

10

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

166

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see pages 192-194

For Use With Copper Cables Only

Type LCA-H

INSPECTION

WINDOW

W

45   5˚

+

_

A

*UL Listed with code, locomotive and class K & M weld cables.
‡Contact

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

Copper Lugs 

One-Hole Lug Standard Barrel, 45

°

Angle Tongue

(continued)

mm

mm

mm

Std.

Pkg.

Qty.

Width (W)

Length (A)

Bolt Hole

Size

Die Colour 

& No.

Copper Conductor

Size*

Part Number

LCA4/0-14H-X

4/0 AWG

Purple P54

6.35

50

26.9

10

LCA4/0-56H-X

7.92

50.3

26.9

10

LCA4/0-38H-X

9.53

52.1

26.9

10

LCA4/0-12H-X

12.7

57.9

26.9

10

LCA250-14H-X

250 kcmil

Yellow P62

6.35

52.1

29.7

10

LCA250-56H-X

7.92

52.3

29.7

10

LCA250-38H-X

9.53

54.1

29.7

10

LCA250-12H-X

12.7

59.9

29.7

10

LCA300-56H-X

300 kcmil

White P66

7.92

64.7

30.2

10

LCA300-38H-X

9.53

64.7

30.2

10

LCA300-12H-X

12.7

68.6

30.2

10

LCA300-58H-X

15.9

72.9

30.2

10

LCA300-78H-X

22.2

84.1

30.2

10

LCA350-38H-X

350 kcmil

Red P71

9.53

65.8

32.5

10

LCA350-12H-X

12.7

68.6

32.5

10

LCA350-58H-X

15.9

73.9

32.5

10

LCA350-78H-X

22.2

85.1

32.5

10

LCA400-38H-6

400 kcmil

Blue P76

9.53

72.4

35.3

6

LCA400-12H-6

12.7

72.4

35.3

6

LCA400-58H-6

15.9

77.7

35.3

6

LCA400-78H-6

22.2

87.6

35.3

6

LCA500-38H-6

500 kcmil

Brown P87

9.53

74.7

39.1

6

LCA500-12H-6

12.7

78.7

39.1

6

LCA500-58H-6

15.9

84.1

39.1

6

LCA500-34H-6

19.1

87.6

39.1

6

LCA500-78H-6

22.2

94

39.1

6

LCA500-1H-6

25.4

97

39.1

6

LCA600-12H-6

600 kmcil

Green P94

12.7

95.5

43.2

6

LCA600-58H-6

15.9

95.5

43.2

6

LCA600-78H-6

22.2

95.5

43.2

6

Panduit-Pannet-html.html
background image

167

For AWG to mm

2

conversion tables see pages 192-194

For Use With Copper Cables Only

Type LCA-F

W

INSPECTION
WINDOW

90   5˚

+

_

A

Copper Lugs 

One-Hole Lug Standard Barrel, 90

°

Angle Tongue

• Colour coded to show proper die number and colour
• Tested by Telcordia and meets NEBS level 3

• UL Listed per 486A up to 35KV**
• Inspection window to visually assure full cable insertion

*UL Listed with code, locomotive and class K & M weld cables.
‡Contact

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

LCA-F product listing continued on the following page

Part Number

Copper Conductor

Size

*

Die Colour &

No.

Bolt Hole

Size

Length (A) Width (W)

Std.

Pkg.

Qty.

mm

mm

mm

LCA10-14F-L

#14–#10 AWG STR,

#12-#10 AWG SOL

6.35

23.9

10.7

50

LCA8-10F-L

#8 AWG

Red P21

4.83

22.9

10.4

50

LCA8-14F-L

6.35

25.1

12.2

50

LCA8-56F-L

7.92

28.2

14.2

50

LCA8-38F-L

9.53

30.7

15.2

50

LCA6-10F-L

#6 AWG

Blue P24

4.83

23.9

11.4

50

LCA6-14F-L

6.35

26.2

11.4

50

LCA6-56F-L

7.92

29.2

14.2

50

LCA6-38F-L

9.53

31.8

15.7

50

LCA4-10F-L

#4 – #3 AWG STR,

#2 AWG SOL

Grey P29

4.83

26.2

14.0

50

LCA4-14F-L

6.35

28.4

14.0

50

LCA4-56F-L

7.92

31.5

14.0

50

LCA4-38F-L

9.53

34

15.7

50

LCA2-14F-Q

#2 AWG

Brown P33

6.35

31.5

15.2

25

LCA2-56F-Q

7.92

34.5

16.8

25

LCA2-38F-Q

9.53

36.6

16.8

25

LCA2-12F-Q

12.7

42.4

19.0

25

LCA1-14F-E

#1 AWG

Green P37

6.35

33.3

17.8

20

LCA1-56F-E

7.92

36.6

17.8

20

LCA1-38F-E

9.53

38.4

17.8

20

LCA1-12F-E

12.7

44.4

19.0

20

LCA1/0-14F-X

1/0 AWG

Pink P42

6.35

36.8

19.3

10

LCA1/0-56F-X

7.92

38.4

19.3

10

LCA1/0-38F-X

9.53

40.1

19.3

10

LCA1/0-12F-X

12.7

46.2

20.3

10

LCA2/0-14F-X

2/0 AWG

Black P45

6.35

40.9

21.6

10

LCA2/0-56F-X

7.92

40.4

21.6

10

LCA2/0-38F-X

9.53

42.2

21.6

10

LCA2/0-12F-X

12.7

48.5

21.6

10

LCA3/0-14F-X

3/0 AWG

Orange P50

6.35

42.4

24.4

10

LCA3/0-56F-X

7.92

42.4

24.4

10

LCA3/0-38F-X

9.53

43.9

24.4

10

LCA3/0-12F-X

12.7

50.3

24.4

10

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

168

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see pages 192-194

Type LCA-F

For Use With Copper Cables Only

*UL Listed with code, locomotive and class K & M weld cables.
‡Contact

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

Copper Lugs 

One-Hole Lug Standard Barrel, 90

°

Angle

Tongue (continued)

W

INSPECTION
WINDOW

90   5˚

+

_

A

mm

mm

mm

Std.

Pkg.

Qty.

Width (W)

Length (A)

Bolt Hole

Size

Die Colour &

No.

Copper Conductor

Size

*

Part Number

LCA4/0-14F-X

4/0 AWG

Purple P54

6.35

44.4

26.9

10

LCA4/0-56F-X

7.92

45

26.9

10

LCA4/0-38F-X

9.53

46.7

26.9

10

LCA4/0-12F-X

12.7

52.6

26.9

10

LCA250-14F-X

250 kcmil

Yellow P62

6.35

46.2

29.7

10

LCA250-56F-X

7.92

46.5

29.7

10

LCA250-38F-X

9.53

48.3

29.7

10

LCA250-12F-X

12.7

54.1

29.7

10

LCA300-56F-X

300 kcmil

White P66

7.92

52.6

30.2

10

LCA300-38F-X

9.53

52.6

30.2

10

LCA300-12F-X

12.7

55.4

30.2

10

LCA300-58F-X

15.9

61

30.2

10

LCA300-78F-X

22.2

71.9

30.2

10

LCA350-38F-X

350 kcmil

Red P71

9.53

54.1

32.5

10

LCA350-12F-X

12.7

56.9

32.5

10

LCA350-58F-X

15.9

62.2

32.5

10

LCA350-78F-X

22.2

73.4

32.5

10

LCA400-38F-6

400 kcmil

Blue P76

9.53

60.2

35.3

6

LCA400-12F-6

12.7

60.2

35.3

6

LCA400-78F-6

22.2

75.4

35.3

6

LCA500-38F-6

500 kcmil

Brown P87

9.53

58.9

39.1

6

LCA500-12F-6

12.7

63

39.1

6

LCA500-34F-6

19.1

71.9

39.1

6

LCA500-78F-6

22.2

76.5

39.1

6

LCA500-1F-6

25.4

81.3

39.1

6

LCA600-12F-6

600 kcmil

Green P94

12.7

81.5

43.2

6

LCA600-78F-6

22.2

81.5

43.2

6

Panduit-Pannet-html.html
background image

169

For AWG to mm

2

conversion tables see pages 192-194

For Use With Copper Cables Only

Type LCD

Copper Lugs 

Two-Hole Lug Standard Barrel

• Colour coded to show proper die number and colour
• Tested by Telcordia and meets NEBS level 3

• UL Listed per 486A up to 35KV**
• Inspection window to visually assure full cable insertion

INSPECTION

WINDOW

A

HOLE

SPACING

INSPECTION

WINDOW

A

HOLE

SPACING

*UL Listed and CSA Certified with code, locomotive and class K & M weld cables.
‡Contact

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

NEMA hole sizes and spacing

LCD product listing continued on the following page

Part Number

Copper

Conductor

Size

Die

Colour

& No. 

Bolt Hole

Size

Length

(A)

Width (W)

Mounting

Hole Spacing

Std.

Pkg.

Qty.

mm

mm

mm

mm

LCD10-10A-L

#14 – #10

AWG STR

#12 – #10

AWG SOL

4.83

42.9

9.7

16

50

LCD10-14A-L

6.35

45.2

10.7

16

50

LCD10-14B-L

6.35

48.5

10.7

19

50

LCD10-14D-L

6.35

54.9

10.7

25.4

50

LCD10-38D-L

9.53

60.5

14.2

25.4

50

LCD8-10A-L

#8 AWG

Red
P21

4.83

47.8

10.4

16

50

LCD8-14A-L

6.35

50.0

12.2

16

50

LCD8-14B-L

6.35

53.1

12.2

19

50

LCD8-14D-L

6.35

59.4

12.2

25.4

50

LCD8-38D-L

9.53

65.0

15.2

25.4

50

LCD8-38AD-L

10.3

65.0

15.7

16

50

LCD6-10A-L

#6 AWG

Blue

P24

4.83

54.6

11.7

16

50

LCD6-14A-L

6.35

56.9

12.2

16

50

LCD6-14B-L

6.35

59.9

12.2

19

50

LCD6-14D-L

6.35

66.3

12.2

25.4

50

LCD6-56D-L

7.92

69.3

14.2

25.4

50

LCD6-38D-L

9.53

71.9

15.7

25.4

50

LCD6-38AD-L

10.3

71.9

15.7

16

50

LCD4-10A-L

#4 – #3 AWG

STR, #2

AWG SOL

Grey

P29

4.83

55.1

14.0

16

50

LCD4-10B-L

4.83

58.2

14.0

19

50

LCD4-14A-L

6.35

57.4

14.0

16

50

LCD4-14B-L

6.35

60.5

14.0

19

50

LCD4-14D-L

6.35

66.8

14.0

25.4

50

LCD4-38D-L

9.53

72.4

15.7

25.4

50

LCD4-38AD-L

10.3

72.3

15.7

16

50

LCD2-14A-Q

#2 AWG

Brown

P33

6.35

61.0

15.2

16

25

LCD2-14B-Q

6.35

64.0

15.2

19

25

LCD2-14D-Q

6.35

70.4

15.2

25.4

25

LCD2-56B-Q

7.92

67.3

16.8

19

25

LCD2-38D-Q

9.53

76.2

16.8

25.4

25

LCD2-38AD-Q

10.3

76.2

16.8

16

25

LCD2-12-Q

12.7

105.2

19.0

44.4

25

LCD1-14A-E

#1 AWG

Green

P37

6.35

61.5

17.8

16

20

LCD1-14B-E

6.35

64.5

17.8

19

20

LCD1-56C-E

7.92

70.9

17.8

22.4

20

LCD1-38D-E

9.53

75.9

17.8

25.4

20

LCD1-38AD-E

16

75.9

17.8

16

20

LCD1-12-E

12.7

105.7

19.0

44.4

20

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

170

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see pages 192-194

For Use With Copper Cables Only

Type LCD

INSPECTION

WINDOW

A

HOLE

SPACING

*UL Listed and CSA Certified with code, locomotive and class K & M weld cables.
‡Contact

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

NEMA hole sizes and spacing

Copper Lugs 

Two-Hole Lug Standard Barrel (continued)

INSPECTION

WINDOW

A

HOLE

SPACING

mm

mm

mm

mm

Std.

Pkg.

Qty.

Mounting

Hole Spacing

Width (W)

Length

(A)

Bolt Hole

Size

Die

Colour

& No. 

Copper

Conductor

Size

Part Number

LCD1/0-14A-X

1/0 AWG

Pink

P42

6.35

65.3

19.3

16

10

LCD1/0-14B-X

6.35

68.6

19.3

19

10

LCD1/0-56C-X

7.92

73.2

19.3

22.4

10

LCD1/0-38D-X

9.53

78.2

19.3

25.4

10

LCD1/0-38AD-X

10.3

78.2

19.3

16

10

LCD1/0-12-X

12.7

107.9

20.3

44.4

10

LCD2/0-14A-X

2/0 AWG

Black

P45

6.35

68.6

21.6

16

10

LCD2/0-14B-X

6.35

71.9

21.6

19

10

LCD2/0-56C-X

7.92

74.9

21.6

22.4

10

LCD2/0-38D-X

9.53

79.8

21.6

25.4

10

LCD2/0-12-X

12.7

109.2

21.6

44.4

10

LCD3/0-14B-X

3/0 AWG

Orange

P50

6.35

76.7

24.4

19

10

LCD3/0-56D-X

7.92

83.1

24.4

25.4

10

LCD3/0-38D-X

9.53

84.6

24.4

25.4

10

LCD3/0-12-X

12.7

114.0

24.4

44.4

10

LCD4/0-14B-X

4/0 AWG

Purple

P54

6.35

78.7

26.9

19

10

LCD4/0-38D-X

9.53

87.4

26.9

25.4

10

LCD4/0-12-X

12.7

116.3

26.9

44.4

10

LCD250-38D-X

250 kcmil

Yellow

P62

9.53

89.9

29.7

25.4

10

LCD250-12-X

12.7

118.9

29.7

44.4

10

LCD300-38D-X

300 kcmil

White

P66

9.53

95.0

30.2

25.4

10

LCD300-12-X

12.7

125.0

30.2

44.4

10

LCD350-14B-X

350 kcmil

Red
P71

6.35

83.8

32.5

19

10

LCD350-38D-X

9.53

96.0

32.5

25.4

10

LCD350-12E-X

12.7

110.0

32.5

31.8

10

LCD350-12-X

12.7

126.0

32.5

44.4

10

LCD400-38D-6

400 kcmil

Blue

P76

9.53

98.0

35.3

25.4

6

LCD400-12-6

12.7

128.0

35.3

44.4

6

LCD500-14B-6

500 kcmil

Brown

P87

6.35

94.2

39.1

19

6

LCD500-38D-6

9.53

106.4

39.1

25.4

6

LCD500-12E-6

12.7

120.4

39.1

31.8

6

LCD500-12-6

12.7

136.4

39.1

44.4

6

LCD600-38D-6

600 kcmil

Green

P94

9.53

107.7

43.2

25.4

6

LCD600-12-6

12.7

137.7

43.2

44.4

6

LCD750-12-6

750 kcmil

Black

P106

12.7

143.5

48.0

44.4

6

LCD1000-12-3

1000 kcmil

White

P125

12.7

146.6

55.1

44.4

3

Panduit-Pannet-html.html
background image

171

For Use With Copper Cables Only

Type LCD-H

W

INSPECTION

WINDOW

45   5˚

+

_

HOLE

SPACING

• Colour coded to show

proper die number
and colour 

• Tested by Telcordia and

meets NEBS level 3

• UL Listed per 486A up

to 35KV**

• Inspection window to

visually assure full
cable insertion

Copper Lugs 

Two-Hole Lug Standard Barrel 

45

°

Angle Tongue

*UL Listed and CSA Certified with code, locomotive and class K & M weld cables.
‡Contact

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

◆ 

NEMA hole sizes and spacing

Part Number

Copper

Conductor

Size

*

Die

Colour
& No.

Bolt Hole

Size

Length

(A)

Width

(W)

Mounting Hole

Spacing

Std.

Pkg.

Qty.

mm

mm

mm

mm

LCD10-10AH-L

#14 – #10

AWG STR

#12 – #10

AWG SOL

4.83

40.4

9.7

16

50

LCD10-14AH-L

6.35

42.4

10.7

16

50

LCD10-38DH-L

9.53

57.9

14.2

25.4

50

LCD8-10AH-L

#8 AWG

Red

P21b

4.83

43.9

10.4

16

50

LCD8-14AH-L

6.35

46.0

12.2

16

50

LCD8-14BH-L

6.35

49.3

12.2

19

50

LCD8-14DH-L

6.35

55.6

12.2

25.4

50

LCD8-38DH-L

9.53

61.0

15.7

25.4

50

LCD6-10AH-L

#6 AWG

Blue

P24

4.83

48.8

11.7

16

50

LCD6-14AH-L

6.35

50.8

12.2

16

50

LCD6-14BH-L

6.35

54.1

12.2

19

50

LCD6-14DH-L

6.35

60.5

12.2

25.4

50

LCD6-56DH-L

7.92

63.2

14.2

25.4

50

LCD6-38DH-L

9.53

65.8

15.7

25.4

50

LCD4-14AH-L

#4 – #3 AWG

STR, #2

AWG SOL

Grey

P29

6.35

51.6

14.0

16

50

LCD4-14BH-L

6.35

54.6

14.0

19

50

LCD4-14DH-L

6.35

61.0

14.0

25.4

50

LCD4-38DH-L

9.53

66.5

15.7

25.4

50

LCD2-14AH-Q

#2 AWG

Brown

P33

6.35

53.6

15.2

16

25

LCD2-14BH-Q

6.35

56.9

15.2

19

25

LCD2-14DH-Q

6.35

63.2

15.2

25.4

25

LCD2-56BH-Q

7.92

59.9

16.8

19

25

LCD2-38DH-Q

9.53

68.8

16.8

25.4

25

LCD2-12H-Q

12.7

97.5

19.0

44.4

25

LCD1-14AH-E

#1 AWG

Green

P37

6.35

53.8

17.8

16

20

LCD1-14BH-E

6.35

57.2

17.8

19

20

LCD1-56CH-E

7.92

63.5

17.8

22.4

20

LCD1-38DH-E

9.53

68.6

17.8

25.4

20

LCD1-12H-E

12.7

98.3

19.0

44.4

20

LCD1/0-14AH-X

1/0 AWG

Pink

P42

6.35

57.4

19.3

16

10

LCD1/0-14BH-X

6.35

60.5

19.3

19

10

LCD1/0-56CH-X

7.92

65.0

19.3

22.4

10

LCD1/0-38DH-X

9.53

99.8

19.3

25.4

10

LCD1/0-12H-X

12.7

99.8

20.3

44.4

10

LCD2/0-14AH-X

2/0 AWG

Black

P45

6.35

60.7

21.6

16

10

LCD2/0-14BH-X

6.35

64.0

21.6

19

10

LCD2/0-56CH-X

7.92

67.1

21.6

22.4

10

LCD2/0-38DH-X

9.53

71.9

21.6

25.4

10

LCD2/0-12H-X

12.7

101.3

21.6

44.4

10

LCD3/0-14BH-X

3/0 AWG

Orange

P50

6.35

67.3

24.4

19

10

LCD3/0-56DH-X

7.92

73.7

24.4

25.4

10

LCD3/0-38DH-X

9.53

75.2

24.4

25.4

10

LCD3/0-12H-X

12.7

104.6

24.4

44.4

10

LCD4/0-14BH-X

4/0 AWG

Purple

P54

6.35

69.1

26.9

19

10

LCD4/0-38DH-X

9.53

77.5

26.9

25.4

10

LCD4/0-12H-X

12.7

106.4

26.9

44.4

10

LCD250-38DH-X

250 kcmil

Yellow

P62

9.53

79.5

29.7

25.4

10

LCD250-12H-X

12.7

108.5

29.7

44.4

10

For AWG to mm

2

conversion tables see pages 192-194

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

172

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For Use With Copper Cables Only

Type LCD-F

Copper Lugs 

Two-Hole Lug Standard Barrel, 90

°

Angle Tongue

• Colour coded to show

proper die number
and colour 

• Tested by Telcordia and

meets NEBS level 3

• UL Listed per 486A

up to 35KV**

• Inspection window to

visually assure full
cable insertion

*UL Listed with code, locomotive and class K & M weld cables.
‡Contact

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

NEMA hole sizes and spacing.

INSPECTION
WINDOW

90   5˚

+

_

W

HOLE

SPACING

Part Number

Copper

Conductor

Size

*

Die

Colour
& No.

Bolt Hole

Size

Length

(A)

Width

(W)

Mounting Hole

Spacing

Std.

Pkg.

Qty.

mm

mm

mm

mm

LCD10-10AF-L

#14 – #10

AWG STR

#12 – #10

AWG SOL

4.83

37.3

9.7

16

50

LCD10-14AF-L

6.35

39.6

10.7

16

50

LCD10-38DF-L

9.53

54.9

14.2

25.4

50

LCD8-10AF-L

#8 AWG

Red
P21

4.83

38.9

10.4

16

50

LCD8-14AF-L

6.35

41.1

12.2

16

50

LCD8-14BF-L

6.35

44.2

12.2

19

50

LCD8-14DF-L

6.35

50.5

12.2

25.4

50

LCD8-38DF-L

9.53

56.1

15.7

25.4

50

LCD6-10AF-L

#6 AWG

Blue

P24

4.83

39.9

11.7

16

50

LCD6-14AF-L

6.35

42.2

12.2

16

50

LCD6-14BF-L

6.35

45.2

12.2

19

50

LCD6-14DF-L

6.35

51.6

12.2

25.4

50

LCD6-56DF-L

7.92

54.6

14.2

25.4

50

LCD6-38DF-L

9.53

57.2

15.7

25.4

50

LCD4-14AF-L

#4 – #3 AWG

STR #2

AWG SOL

Grey

P29

6.35

44.2

14.0

16

50

LCD4-14BF-L

6.35

47.5

14.0

19

50

LCD4-14DF-L

6.35

53.8

14.0

25.4

50

LCD4-38DF-L

9.53

59.4

15.7

25.4

50

LCD2-14AF-Q

#2 AWG

Brown

P33

6.35

47.2

15.2

16

25

LCD2-14BF-Q

6.35

50.5

15.2

19

25

LCD2-14DF-Q

6.35

56.9

15.2

25.4

25

LCD2-56BF-Q

7.92

53.6

16.8

19

25

LCD2-38DF-Q

9.53

62.7

16.8

25.4

25

LCD2-12F-Q

12.7

91.7

19.0

44.4

25

LCD1-14AF-E

#1 AWG

Green

P37

6.35

49.3

17.8

16

20

LCD1-14BF-E

6.35

52.3

17.8

19

20

LCD1-56CF-E

7.92

58.7

17.8

22.4

20

LCD1-38DF-E

9.53

63.8

17.8

25.4

20

LCD1-12F-E

12.7

93.5

19.0

44.4

20

LCD1/0-14AF-X

1/0 AWG

Pink

P42

6.35

52.8

19.3

16

10

LCD1/0-14BF-X

6.35

55.9

19.3

19

10

LCD1/0-56CF-X

7.92

60.5

19.3

22.4

10

LCD1/0-38DF-X

9.53

65.5

19.3

25.4

10

LCD1/0-12F-X

12.7

95.3

20.3

44.4

10

LCD2/0-14AF-X

2/0 AWG

Black

P45

6.35

56.4

21.6

16

10

LCD2/0-14BF-X

6.35

59.4

21.6

19

10

LCD2/0-56CF-X

7.92

62.7

21.6

22.4

10

LCD2/0-38DF-X

9.53

67.7

21.6

25.4

10

LCD2/0-12F-X

12.7

97.0

21.6

44.4

10

LCD3/0-14BF-X

3/0 AWG

Orange

P50

6.35

61.5

24.4

19

10

LCD3/0-56DF-X

7.92

67.8

24.4

25.4

10

LCD3/0-38DF-X

9.53

69.3

24.4

25.4

10

LCD3/0-12F-X

12.7

98.8

24.4

44.4

10

LCD4/0-14BF-X

4/0 AWG

Purple

P54

6.35

63.5

26.9

19

10

LCD4/0-38DF-X

9.53

72.1

26.9

25.4

10

LCD4/0-12F-X

12.7

101.1

26.9

44.4

10

LCD250-38DF-X

250 kcmil

Yellow

P62

9.53

73.7

29.7

25.4

10

LCD250-12F-X

12.7

102.6

29.7

44.4

10

For AWG to mm

2

conversion tables see pages 192-194

Panduit-Pannet-html.html
background image

173

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

For AWG to mm

2

conversion tables see pages 192-194

For Use With Copper Cables Only

One-Piece

Construction

A

INSPECTION

WINDOW

HOLE

SPACING

*UL Listed with code, locomotive
and class K & M weld cables.
‡ Contact 

PANDUIT

for flex cable

tie selection.
**Consult cable manufacturer for
voltage stress relief instructions
with applications greater than
2000 volts.

NEMA hole sizes and spacing.

Copper Lugs 

Two-Hole Lug, Long Barrel, with Inspection Window

• Colour coded to show

proper die number
and colour

• UL Listed per 486A up

to 35KV**

• Tested by Telcordia and

meets NEBS level 3

• Inspection window to

visually assure full
cable insertion

Type LCC-W

LCC-W product listing continued on the following page

Part Number

Copper

Conductor

Size

*

Die

Colour

& No. 

Bolt Hole

Size

Length

(A)

Width

(W)

Mounting Hole

Spacing

Std.

Pkg.

Qty.

mm

mm

mm

mm

LCC10-14AW-L

#14 – #10

AWG STR

#12 – #10

AWG SOL

6.35

49.0

10.7

16

50

LCC10-14BW-L

6.35

52.3

10.7

19

50

LCC8-10AW-L

#8 AWG

Red
P21

4.83

51.3

10.4

16

50

LCC8-10BW-L

4.83

54.4

10.4

19

50

LCC8-14AW-L

6.35

53.3

12.2

16

50

LCC8-14BW-L

6.35

56.6

12.2

19

50

LCC8-14DW-L

6.35

63.0

12.2

25.4

50

LCC8-38DW-L

9.53

68.6

15.2

25.4

50

LCC6-10AW-L

#6 AWG

Blue

P24

4.83

61.0

11.7

16

50

LCC6-10BW-L

4.83

64.0

11.7

19

50

LCC6-14AW-L

6.35

63.2

12.2

16

50

LCC6-14BW-L

6.35

66.3

12.2

19

50

LCC6-14DW-L

6.35

72.6

12.2

25.4

50

LCC6-56BW-L

7.92

69.3

14.2

19

50

LCC6-38BW-L

9.53

71.9

15.7

19

50

LCC6-38CW-L

9.53

75.2

15.7

22.4

50

LCC6-38DW-L

9.53

78.2

15.7

25.4

50

LCC4-10AW-L

#4 – #3 AWG

STR, #2

AWG SOL

Grey

P29

4.83

61.0

14.0

16

50

LCC4-10BW-L

4.83

64.3

14.0

19

50

LCC4-14AW-L

6.35

63.5

14.0

16

50

LCC4-14BW-L

6.35

66.8

14.0

19

50

LCC4-38DW-L

9.53

78.5

15.7

25.4

50

LCC2-10AW-Q

#2 AWG

Brown

P33

4.83

62.3

15.2

16

25

LCC2-10BW-Q

4.83

68.3

15.2

19

25

LCC2-14AW-Q

6.35

67.8

15.2

16

25

LCC2-14BW-Q

6.35

70.9

15.2

19

25

LCC2-14DW-Q

6.35

77.2

15.2

25.4

25

LCC2-56BW-Q

7.92

74.2

16.8

19

25

LCC2-56CW-Q

7.92

77.2

16.8

22.4

25

LCC2-38BW-Q

9.53

75.9

16.8

19

25

LCC2-38CW-Q

9.53

79.2

16.8

22.4

25

LCC2-38DW-Q

9.53

82.3

16.8

25.4

25

LCC2-38W-Q

9.53

101.3

16.8

44.4

25

LCC2-12W-Q

12.7

112.0

19.0

44.4

25

LCC1-14AW-E

#1 AWG

Green

P37

6.35

73.4

17.8

16

20

LCC1-14BW-E

6.35

76.5

17.8

19

20

LCC1-56BW-E

7.92

79.8

17.8

19

20

LCC1-56CW-E

7.92

82.8

17.8

22.4

20

LCC1-38DW-E

9.53

87.9

17.8

25.4

20

LCC1-12W-E

12.7

117.6

19.0

44.4

20

LCC1/0-14AW-X

1/0 AWG

Pink

P42

6.35

78.0

19.3

16

10

LCC1/0-14BW-X

6.35

81.0

19.3

19

10

LCC1/0-14DW-X

6.35

87.4

19.3

25.4

10

LCC1/0-38DW-X

9.53

90.7

19.3

25.4

10

LCC1/0-38W-X

9.53

109.7

19.3

44.4

10

LCC1/0-12DW-X

12.7

97.5

20.3

25.4

10

LCC1/0-12W-X

12.7

120.4

20.3

44.4

10

Panduit-Pannet-html.html
background image

174

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see pages 192-194

For Use With Copper Cables Only

One-Piece Construction

A

INSPECTION

WINDOW

HOLE

SPACING

*UL Listed with code, locomotive and class K & M weld cables.
‡ Contact 

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

NEMA hole sizes and spacing

.

Copper Lugs 

Two-Hole Lug, Long Barrel, with Inspection Window

(continued)

Type LCC-W

mm

mm

mm

mm

Std.

Pkg.

Qty.

Mounting Hole

Spacing

Width

(W)

Length

(A)

Bolt Hole

Size

Die

Colour

& No. 

Copper

Conductor

Size

*

Part Number

LCC2/0-14AW-X

2/0 AWG

Black

P45

6.35

82.0

21.6

16

10

LCC2/0-14BW-X

6.35

85.3

21.6

19

10

LCC2/0-56DW-X

7.92

91.7

21.6

25.4

10

LCC2/0-38DW-X

9.53

93.2

21.6

25.4

10

LCC2/0-12DW-X

12.7

99.6

21.6

25.4

10

LCC2/0-12W-X

12.7

122.7

21.6

44.4

10

LCC3/0-14BW-X

3/0 AWG

Orange

P50

6.35

86.1

24.4

19

10

LCC3/0-56DW-X

7.92

92.5

24.4

25.4

10

LCC3/0-38DW-X

9.53

94.0

24.4

25.4

10

LCC3/0-12W-X

12.7

123.7

24.4

44.4

10

LCC3/0-12DW-X

12.7

100.3

24.4

25.4

10

LCC4/0-14AW-X

4/0 AWG

Purple

P54

6.35

85.1

26.9

16

10

LCC4/0-14BW-X

6.35

88.4

26.9

19

10

LCC4/0-56DW-X

7.92

95.0

26.9

25.4

10

LCC4/0-38DW-X

9.53

96.8

26.9

25.4

10

LCC4/0-38W-X

9.53

115.8

26.9

44.4

10

LCC4/0-12W-X

12.7

125.7

26.9

44.4

10

LCC4/0-12DW-X

12.7

102.6

26.9

25.4

10

LCC250-56DW-X

250 kcmil

Yellow

P62

7.92

97.0

29.7

25.4

10

LCC250-38DW-X

9.53

98.8

29.7

25.4

10

LCC250-12W-X

12.7

127.8

29.7

44.4

10

LCC250-12DW-X

12.7

104.6

29.7

25.4

10

LCC300-38DW-X

300 kcmil

White

P66

9.53

115.3

30.2

25.4

10

LCC300-12W-X

12.7

145.3

30.2

44.4

10

LCC350-14BW-X

350 kcmil

Red
P71

6.35

104.1

32.5

19

10

LCC350-12W-X

12.7

146.3

32.5

44.4

10

LCC400-14BW-6

400 kcmil

Blue

P76

6.35

106.2

35.3

19

6

LCC400-38DW-6

9.53

118.4

35.3

25.4

6

LCC400-12W-6

12.7

148.3

32.5

44.4

6

LCC500-14BW-6

500 kcmil

Brown

P87

6.35

113.3

39.1

19

6

LCC500-38DW-6

9.53

125.5

39.1

25.4

6

LCC500-12W-6

12.7

155.4

39.1

44.4

6

LCC600-38DW-6

600 kcmil

Green

P94

9.53

131.6

43.2

25.4

6

LCC600-12W-6

12.7

161.5

43.2

44.4

6

LCC750-38DW-6

750 kcmil

Black

P106

9.53

145.0

48.0

25.4

6

LCC750-12W-6

12.7

168.9

48.0

44.4

6

LCC800-12W-6

800 kcmil

Orange

P107

12.7

171.2

49.5

44.4

6

LCC1000-38DW-3

1000 kcmil

White

P125

9.53

151.1

55.1

25.4

3

LCC1000-12W-3

12.7

175.0

55.1

44.4

3

Panduit-Pannet-html.html
background image

175

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

For AWG to mm

2

conversion tables see pages 192-194

For Use With Copper Cables Only

Type LCC-WH

*UL Listed and CSA Certified with code, locomotive and class K & M weld cables.
‡ Contact 

PANDUIT

for flex cable die selection. 

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

Copper Lugs -Two Hole Lug, Long Barrel, With Window -
45

°

Angle Tongue

• Colour coded to show

proper die number
and colour

• UL Listed per 486A up

to 35KV**

• Tested by Telcordia and

meets NEBS level 3

• Inspection window to

visually assure full
cable insertion

W

HOLE

SPACING

INSPECTION

WINDOW

T

L

B

45˚

LCC-WH product listing continued on the following page

Part Number

Copper

Conductor

Size

*

Die

Colour
& No.

Bolt Hole

Size

Length

(A)

Width

(W)

Mounting Hole

Spacing

Std.

Pkg.

Qty.

mm

mm

mm

mm

LCC10-14AWH-L

#14 – #10

AWG STR

#12 – #10

AWG SOL

6.35

45.2

10.7

16

50

LCC10-14BWH-L

6.35

48.3

10.7

19

50

LCC8-10AWH-L

#8 AWG

Red

P21b

4.83

46.2

10.4

16

50

LCC8-10BWH-L

4.83

49.5

10.4

19

50

LCC8-14AWH-L

6.35

48.5

12.2

16

50

LCC8-14BWH-L

6.35

51.6

12.2

19

50

LCC8-14DWH-L

6.35

57.9

12.2

25.4

50

LCC8-38DWH-L

9.53

63.2

15.2

25.4

50

LCC6-10AWH-L

#6 AWG

Blue

P24

4.83

53.1

11.7

16

50

LCC6-10BWH-L

4.83

56.4

11.7

19

50

LCC6-14AWH-L

6.35

55.4

12.2

16

50

LCC6-14BWH-L

6.35

58.7

12.2

19

50

LCC6-14DWH-L

6.35

65.0

12.2

25.4

50

LCC6-56BWH-L

7.92

61.5

14.2

19

50

LCC6-38BWH-L

9.53

64.0

15.7

19

50

LCC6-38CWH-L

9.53

67.1

15.7

22.4

50

LCC6-38DWH-L

9.53

70.4

15.7

25.4

50

LCC4-10AWH-L

#4 – #3 AWG

STR, #2

AWG SOL

Grey

P29

4.83

53.6

14.0

16

50

LCC4-10BWH-L

4.83

53.6

14.0

19

50

LCC4-14AWH-L

6.35

55.9

14.0

16

50

LCC4-14BWH-L

6.35

56.6

14.0

19

50

LCC4-38DWH-L

9.53

70.9

15.7

25.4

50

LCC2-10AWH-Q

#2 AWG

Brown

P33

4.83

56.1

15.2

16

25

LCC2-10BWH-Q

4.83

59.2

15.2

19

25

LCC2-14AWH-Q

6.35

58.7

15.2

16

25

LCC2-14BWH-Q

6.35

59.2

15.2

19

25

LCC2-14DWH-Q

6.35

68.1

15.2

25.4

25

LCC2-56BWH-Q

7.92

64.8

16.8

19

25

LCC2-56CWH-Q

7.92

68.1

16.8

22.4

25

LCC2-38BWH-Q

9.53

66.8

16.8

19

25

LCC2-38CWH-Q

9.53

69.9

16.8

22.4

25

LCC2-38DWH-Q

9.53

73.2

16.8

25.4

25

LCC2-38WH-Q

9.53

92.2

16.8

19

25

LCC2-12WH-Q

12.7

102.4

19.0

44.4

25

LCC1-14AWH-E

#1 AWG

Green

P37

6.35

102.4

17.8

16

20

LCC1-14BWH-E

6.35

65.5

17.8

19

20

LCC1-56BWH-E

7.92

68.8

17.8

19

20

LCC1-56CWH-E

7.92

71.9

17.8

22.4

20

LCC1-38DWH-E

9.53

77.2

17.8

25.4

20

LCC1-12WH-E

12.7

106.7

19.0

44.4

20

Panduit-Pannet-html.html
background image

176

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see pages 192-194

For Use With Copper Cables Only

Type LCC-WH

*UL Listed and CSA Certified with code, locomotive and class K & M weld cables.
‡ Contact 

PANDUIT

for flex cable die selection. 

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

Copper Lugs -Two Hole Lug, Long Barrel, With Window
45

°

Angle Tongue (continued)

W

HOLE

SPACING

INSPECTION

WINDOW

T

L

B

mm

mm

mm

mm

Std.

Pkg.

Qty.

Mounting Hole

Spacing

Width

(W)

Length

(A)

Bolt Hole

Size

Die

Colour
& No.

Copper

Conductor

Size

*

Part Number

LCC1/0-14AWH-X

1/0 AWG

Pink

P42

6.35

66.3

19.3

16

10

LCC1/0-14BWH-X

6.35

69.3

19.3

19

10

LCC1/0-14DWH-X

6.35

75.7

19.3

25.4

10

LCC1/0-38DWH-X

9.53

79.0

19.3

25.4

10

LCC1/0-38WH-X

9.53

98.0

19.3

44.4

10

LCC1/0-12DWH-X

12.7

85.6

20.3

25.4

10

LCC1/0-12WH-X

12.7

108.7

20.3

44.4

10

LCC2/0-14AWH-X

2/0 AWG

Black

P45

6.35

70.1

21.6

16

10

LCC2/0-14BWH-X

6.35

73.2

21.6

19

10

LCC2/0-56DWH-X

7.92

79.5

21.6

25.4

10

LCC2/0-38DWH-X

9.53

81.3

21.6

25.4

10

LCC2/0-12DWH-X

12.7

87.6

21.6

25.4

10

LCC2/0-12WH-X

12.7

110.7

21.6

44.4

10

LCC3/0-14BWH-X

3/0 AWG

Orange

P50

6.35

73.9

24.4

19

10

LCC3/0-56DWH-X

7.92

80.3

24.4

25.4

10

LCC3/0-38DWH-X

9.53

81.8

24.4

25.4

10

LCC3/0-12DWH-X

12.7

88.1

24.4

25.4

10

LCC3/0-12WH-X

12.7

111.3

24.4

44.4

10

LCC4/0-14BWH-X

4/0 AWG

Purple

P54

6.35

75.7

26.9

19

10

LCC4/0-56DWH-X

7.92

92.3

26.9

25.4

10

LCC4/0-38DWH-X

9.53

84.1

26.9

25.4

10

LCC4/0-38WH-X

9.53

103.1

26.9

44.4

10

LCC4/0-12DWH-X

12.7

103.1

26.9

25.4

10

LCC4/0-12WH-X

12.7

113.0

26.9

44.4

10

LCC250-56DWH-X

250 kcmil

Yellow

P62

7.92

84.1

29.7

25.4

10

LCC250-38DWH-X

9.53

85.6

29.7

25.4

10

LCC250-12DWH-X

12.7

91.7

29.7

25.4

10

LCC250-12WH-X

12.7

114.8

29.7

44.4

10

LCC300-38DWH-X

300 kcmil

White

P66

9.53

99.8

30.2

25.4

10

LCC300-12WH-X

12.7

129.8

30.2

44.4

10

LCC350-14BWH-X

350 kcmil

Red
P71

6.35

88.4

32.5

19

10

LCC350-38DWH-X

9.53

100.6

32.5

25.4

10

LCC350-12WH-X

12.7

130.6

32.5

44.4

10

LCC400-14BWH-6

400 kcmil

Blue 76

6.35

91.2

35.3

19

6

LCC400-38DWH-6

9.53

103.4

35.3

25.4

6

LCC400-12WH-6

12.7

133.1

35.3

44.4

6

LCC500-14BWH-6

500 kcmil

Brown

P87

6.35

96.5

39.1

19

6

LCC500-38DWH-6

9.53

109.0

39.1

5.4

6

LCC500-12WH-6

12.7

138.7

39.1

44.4

6

LCC600-38DWH-6

600 kcmil

Green

P94

9.53

113.5

43.2

25.4

6

LCC600-12WH-6

12.7

143.5

43.2

44.4

6

Panduit-Pannet-html.html
background image

177

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

For AWG to mm

2

conversion tables see pages 192-194

For Use With Copper Cables Only

Type LCC-WF

*UL Listed and CSA Certified with code, locomotive and class K & M weld cables.
‡Contact

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

INS
WIN

W

HOLE

SPACING

T

B

L

90˚

Copper Lugs - Two-Hole Lug, Long Barrel with Window -
90

°

Angle Tongue

• Colour coded to

show proper die
number and colour

• UL Listed per 486A

up to 35KV**

• Tested by Telcordia

and meets NEBS
level 3

• Inspection window to

visually assure full
cable insertion

LCC-WF product listing continued on the following page

Part Number

Copper

Conductor

Size

*

Die

Colour
& No.

Bolt Hole

Size

Length

(A)

Width

(W)

Mounting Hole

Spacing

Std.

Pkg.

Qty.

mm

mm

mm

mm

LCC10-14AWF-L

#14 – #10

AWG STR

#12 – #10

AWG SOL

6.35

39.9

10.7

16

50

LCC10-14BWF-L

6.35

42.9

10.7

19

50

LCC8-10AWF-L

#8 AWG

Red

P21b

4.83

38.9

10.4

16

50

LCC8-10BWF-L

4.83

41.9

10.4

19

50

LCC8-14AWF-L

6.35

40.9

12.2

16

50

LCC8-14BWF-L

6.35

44.2

12.2

19

50

LCC8-14DWF-L

6.35

50.5

12.2

25.4

50

LCC8-38DWF-L

9.53

56.1

15.2

25.4

50

LCC6-10AWF-L

#6 AWG

Blue

P24

4.83

39.9

11.7

16

50

LCC6-10BWF-L

4.83

42.9

11.7

19

50

LCC6-14AWF-L

6.35

42.2

12.2

16

50

LCC6-14BWF-L

6.35

45.2

12.2

19

50

LCC6-14DWF-L

6.35

51.6

12.2

25.4

50

LCC6-56BWF-L

7.92

48.3

14.2

19

50

LCC6-38BWF-L

9.53

50.8

15.7

19

50

LCC6-38CWF-L

9.53

54.1

15.7

22.4

50

LCC6-38DWF-L

9.53

57.2

15.7

25.4

50

LCC4-10AWF-L

#4 – #3 AWG

STR, #2

AWG SOL

Grey

P29

4.83

41.9

14.0

16

50

LCC4-10BWF-L

4.83

45.2

14.0

19

50

LCC4-14AWF-L

6.35

44.2

14.0

16

50

LCC4-14BWF-L

6.35

47.5

14.0

19

50

LCC4-38DWF-L

9.53

59.4

15.7

25.4

50

LCC2-10AWF-Q

#2 AWG

Brown

P33

4.83

44.7

15.2

16

25

LCC2-10BWF-Q

4.83

48.0

15.2

19

25

LCC2-14AWF-Q

6.35

47.2

15.2

16

25

LCC2-14BWF-Q

6.35

50.5

15.2

19

25

LCC2-14DWF-Q

6.35

56.9

15.2

25.4

25

LCC2-56BWF-Q

7.92

53.6

16.8

19

25

LCC2-56CWF-Q

7.92

56.9

16.8

22.4

25

LCC2-38BWF-Q

9.53

55.6

16.8

19

25

LCC2-38CWF-Q

9.53

58.7

16.8

22.4

25

LCC2-38DWF-Q

9.53

62.0

16.8

25.4

25

LCC2-38WF-Q

9.53

81.0

16.8

44.4

25

LCC2-12WF-Q

12.7

91.7

19.0

44.4

25

LCC1-14AWF-E

#1 AWG

Green

P37

6.35

49.3

17.8

16

20

LCC1-14BWF-E

6.35

52.3

17.8

19

20

LCC1-56BWF-E

7.92

55.6

17.8

19

20

LCC1-56CWF-E

7.92

58.7

17.8

22.4

20

LCC1-38DWF-E

9.53

63.8

17.8

25.4

20

LCC1-12WF-E

12.7

93.5

19.0

44.4

20

Panduit-Pannet-html.html
background image

178

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see pages 192-194

For Use With Copper Cables Only

Type LCC

*UL Listed and CSA Certified with code, locomotive and class K & M weld cables.
‡Contact

PANDUIT

for flex cable die selection.

**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

INS
WIN

W

HOLE

SPACING

T

B

L

90˚

Copper Lugs - Two-Hole Lug, Long Barrel with Window -
90

°

Angle Tongue (continued)

mm

mm

mm

mm

Std.

Pkg.

Qty.

Mounting Hole

Spacing

Width

(W)

Length

(A)

Bolt Hole

Size

Die

Colour
& No.

Copper

Conductor

Size

*

Part Number

LCC1/0-14AWF-X

1/0 AWG

Pink

P42

6.35

52.8

19.3

16

10

LCC1/0-14BWF-X

6.35

55.9

19.3

19

10

LCC1/0-14DWF-X

6.35

62.2

19.3

25.4

10

LCC1/0-38DWF-X

9.53

65.5

19.3

25.4

10

LCC1/0-38WF-X

9.53

84.6

19.3

44.4

10

LCC1/0-12DWF-X

12.7

72.4

20.3

25.4

10

LCC1/0-12WF-X

12.7

95.3

20.3

44.4

10

LCC2/0-14AWF-X

2/0 AWG

Black

P45

6.35

56.4

21.6

16

10

LCC2/0-14BWF-X

6.35

59.4

21.6

19

10

LCC2/0-56DWF-X

7.92

65.8

21.6

25.4

10

LCC2/0-38DWF-X

9.53

67.7

21.6

25.4

10

LCC2/0-12DWF-X

12.7

73.9

21.6

25.4

10

LCC2/0-12WF-X

12.7

97.0

21.6

44.4

10

LCC3/0-14BWF-X

3/0 AWG

Orange

P50

6.35

61.5

24.4

19

10

LCC3/0-56DWF-X

7.92

67.8

24.4

25.4

10

LCC3/0-38DWF-X

9.53

69.3

24.4

25.4

10

LCC3/0-12DWF-X

12.7

75.7

24.4

25.4

10

LCC3/0-12WF-X

12.7

98.8

24.4

44.4

10

LCC4/0-14BWF-X

4/0 AWG

Purple

P54

6.35

63.5

26.9

19

10

LCC4/0-56DWF-X

7.92

70.4

26.9

25.4

10

LCC4/0-38DWF-X

9.53

72.1

26.9

25.4

10

LCC4/0-38WF-X

9.53

91.2

26.9

44.4

10

LCC4/0-12DWF-X

12.7

78.0

26.9

25.4

10

LCC4/0-12WF-X

12.7

101.1

26.9

44.4

10

LCC250-56DWF-X

250 kcmil

Yellow

P62

7.92

71.9

29.7

25.4

10

LCC250-38DWF-X

9.53

73.7

29.7

25.4

10

LCC250-12DWF-X

12.7

79.5

29.7

25.4

10

LCC250-12WF-X

12.7

102.6

29.7

44.4

10

LCC300-38DWF-X

300 kcmil

White

P66

9.53

73.2

30.2

25.4

10

LCC300-12WF-X

12.7

103.1

30.2

44.4

10

LCC350-14BWF-X

350 kcmil

Red
P71

6.35

62.5

32.5

19

10

LCC350-38DWF-X

9.53

74.7

32.5

25.4

10

LCC350-12WF-X

12.7

104.6

32.5

44.4

10

LCC400-14BWF-6

400 kcmil

Blue

P76

6.35

64.5

35.3

19

6

LCC400-38DWF-6

9.53

76.7

35.3

25.4

6

LCC400-12WF-6

12.7

106.7

35.3

44.4

6

LCC500-14BWF-6

500 kcmil

Brown

P87

6.35

67.3

39.1

19

6

LCC500-38DWF-6

9.53

79.5

39.1

25.4

6

LCC500-12WF-6

12.7

109.5

39.1

44.4

6

LCC600-38DWF-6

600 kcmil

Green

P94

9.53

82.8

43.2

25.4

6

LCC600-12WF-6

12.7

112.8

43.2

44.4

6

Panduit-Pannet-html.html
background image

179

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

For AWG to mm

2

conversion tables see pages 192-194

Copper Splices - Butt Splices, Standard Barrel

• Colour coded to show proper

die number and colour for code
cable

• UL Listed and CSA Certified

with code cables

• UL Listed per 486A up to

35KV**

*U.L. Listed and CSA Certified with code, locomotive and class K & M weld cables.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

For Use With Copper Cables Only

Type SCS

Copper Splices - Butt Splices, Long Barrel

• Colour coded to show proper

die number and colour for code
cable

• UL Listed and CSA Certified

with code cables

• UL Listed per 486A up to

35KV**

*U.L. Listed and CSA Certified with code, locomotive and class K & M weld cables.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts.

For Use With Copper Cables Only

Type SCL

O.D.

L

O.D.

L

Part Number

Copper Conductor Size

*

Die Colour &

No.

Barrel

Length

(A)

Std.

Pkg.

Qty.

I.D.

O.D.

mm

SCS8-L

#8 AWG

Red P21

.18

.27

38.1

50

SCS6-L

#6 AWG

Blue P24

.22

.31

44.4

50

SCS4-L

#4 – #3 AWG STR, 

#2 AWG SOL

Grey P29

.28

.38

44.4

50

SCS2-Q

#2 AWG

Brown P33

.31

.42

47.5

25

SCS1-E

#1 AWG

Green P37

.36

.47

47.5

20

SCS1/0-X

1/0 AWG

Pink P42

.39

.52

47.5

10

SCS2/0-X

2/0 AWG

Black P45

.45

.58

50.8

10

SCS3/0-X

3/0 AWG

Orange P50

.51

.64

53.8

10

SCS4/0-X

4/0 AWG

Purple P54

.56

.71

53.8

10

SCS250-X

250 kcmil

Yellow P62

.63

.77

57.2

10

SCS300-X

300 kcmil

White P66

.65

.81

57.2

10

SCS350-X

350 kcmil

Red P71

.70

.87

60.2

10

SCS400-6

400 kcmil

Blue P76

.76

.95

63.5

6

SCS500-6

500 kcmil

Brown P87

.84

1.05

72.9

6

SCS600-6

600 kcmil

Green P94

.92

1.18

72.9

6

SCS750-6

750 kcmil

Black P106

1.03

1.29

85.6

6

SCS1000-3

1000 kcmil

White P125

1.17

1.50

98.3

3

Part Number

Copper Conductor Size

*

Die Colour &

No.

Barrel

Length

(A)

Std.

Pkg.

Qty.

I.D.

O.D.

mm

SCL8-L

#8 AWG

Red P21

.18

.27

57.2

50

SCL6-L

#6 AWG

Blue P24

.22

.31

60.5

50

SCL4-L

#4 – #3 AWG STR, 

#2 AWG SOL

Grey P29

.28

.38

60.5

50

SCL2-Q

#2 AWG

Brown P33

.31

.42

66.5

25

SCL1-E

#1 AWG

Green P37

.36

.47

72.9

20

SCL1/0-X

1/0 AWG

Pink P42

.39

.52

72.9

10

SCL2/0-X

2/0 AWG

Black P45

.45

.58

79.5

10

SCL3/0-X

3/0 AWG

Orange P50

.51

.64

79.2

10

SCL4/0-X

4/0 AWG

Purple P54

.57

.71

85.6

10

SCL250-X

250 kcmil

Yellow P62

.63

.77

85.9

10

SCL300-X

300 kcmil

White P66

.65

.81

104.6

10

SCL350-X

350 kcmil

Red P71

.70

.88

104.6

10

SCL400-6

400 kcmil

Blue P76

.76

.95

111.0

6

SCL500-6

500 kcmil

Brown P87

.84

1.06

117.3

6

SCL600-6

600 kcmil

Green P94

.92

1.19

139.7

6

SCL750-6

750 kcmil

Black P106

1.03

1.30

149.1

6

SCL1000-3

1000 kcmil

White P125

1.17

1.50

155.4

3

Panduit-Pannet-html.html
background image

180

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see pages 192-194

C-Type Taps - Thick Wall Copper Compression

• For tapping into unbroken

continuous main, as a wire
joint or 2-way splice

• UL Listed per 467 for

grounding and bonding,
acceptable for direct burial in
earth or concrete

For Copper-to-Copper Connections

Type CTAP

H

C-Type Taps - Thin Wall Copper Compression

• For stranded copper cable

applications only

• For copper-to-copper tapping

splicing or pigtailing

• Colour coded to show proper

crimp die number and die
colour

• Rated for 600V applications

Type CTAPF

For Copper-To- Copper 

Connections

Q

A

CTAP Covers

• Protect CTAP connection from environment and act

as insulation

• Tapered drains

• Double locking latches
• Made of durable, weather-resistant black polypropylene

L

W

H

CTAPF10-16-C available with square, not flared ends.

Part Number

Copper Conductor Size

Die

Number

Height

(H)

Std.

Pkg.

Qty.

Run

Tap

mm

CTAP4-8-L

#6 – #4 SOL or STR

#8 SOL or STR

PBG

18.5

50

CTAP4-6-L

#6 STR, #4 SOL or STR

#6 SOL or STR

PBG

19.3

50

CTAP4-4-L

#4 SOL or STR

#4 STR

PBG

20.6

50

CTAP2-4-Q

#2 SOL or STR

#8 – #4 SOL or STR

PC

24.4

25

CTAP2-2-X

#2 SOL or STR

#2 SOL or STR

PC

26.7

10

CTAP2/0-2-X

1/0 – 2/0 STR

#8 – #2 SOL or STR

PO

33.5

10

CTAP2/0-2/0-X

1/0 – 2/0 STR

1/0 – 2/0 STR

PO

34.8

10

CTAP4/0-2-X

3/0 – 4/0 STR

#6 – #2 SOL or STR

PD3

42.2

10

CTAP4/0-2/0-X

3/0 – 4/0 STR

1/0 – 2/0 STR

PD3

39.9

10

CTAP4/0-4/0-X

3/0 – 4/0 STR

3/0 – 4/0 STR

PD3

39.9

10

Part Number

Copper Conductor Size (STR)

No. of

Ribs

Inside

Diameter

(Q)

Length

(A)

Std.

Pkg.

Qty.

Run

Tap

mm

mm

CTAPF10-16-C

#14 AWG #12 AWG

#10 AWG

#16 AWG – #14 AWG
#16 AWG – #12 AWG

#14 AWG

0

4.8

10.4

100

CTAPF8-12-C

#10 AWG #8 AWG

#10 AWG #12 AWG

0

6.6

17.0

100

CTAPF6-12-C

#8 AWG #6 AWG

#10 AWG – #8 AWG

#12 AWG – #10 AWG

0

8.1

17.0

100

CTAPF4-12-C

#6 AWG

#5 AWG, #4 AWG

#8 AWG – #6 AWG

#12 AWG – #8 AWG

1

10.21

31.8

100

CTAPF3-12-C

#5 AWG, #4 AWG #3

AWG

#6 AWG – #5 AWG

#12 AWG – #6 AWG

1

11.7

31.8

100

CTAPF2-12-C

#4, #3, #2

#4 AWG #5 AWG 

#12 AWG – #6 AWG

1

13.0

31.8

100

CTAPF1-12-C

#3 AWG 
#2 AWG 
#1 AWG

#4 AWG – #3 AWG 
#5 AWG – #4 AWG

#12 AWG – #5 AWG

2

14.5

46.2

100

CTAPF1/0-12-L

#2 AWG 
#1 AWG 

1/0 AWG

#4 AWG – #2 AWG 
#4 AWG – #3 AWG

#12 AWG – #4 AWG

2

16.0

46.2

50

CTAPF2/0-12-Q

#1 AWG 

1/0 AWG 
2/0 AWG

#2 AWG – #1 AWG 
#3 AWG – #2 AWG

#12 AWG – #3 AWG

2

18.0

46.2

25

CTAPF3/0-12-Q

1/0 AWG 
2/0 AWG 
3/0 AWG

#1 AWG – 1/0 AWG 

#2 AWG – #1 AWG

#12 AWG – #2 AWG

2

20.6

46.2

25

Part Number

For PANDUIT

C-Type Taps

Length

(A)

Width 

(W)

Height

(H)

Std.

Pkg.

Qty.

mm

mm

mm

TAPC2-2/0-X

CTAP2-2, CTAP2-4, 

CTAP4-4, CTAP4-6

117.4

40.6

56.4

10

TAPC3/0-4/0-5

CTAP4/0-4/0

143.5

43.7

60.5

5

Panduit-Pannet-html.html
background image

181

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

For AWG to mm

2

conversion tables see pages 192-194

HTAP Copper Compression Taps

• For making parallel and multiple tap connections on code

and flex cables

• Made of high-conductivity, electro-tin plated copper
• Especially suited for low-resistance, low-voltage

drop grounding

• Accommodate a wide range of conductor combinations

from #14 AWG to 1000 kcmil

• Colour coded to show proper die number and colour
• Crimp with 

PANDUIT

CT-930, CT-930CH, and CT-940CH

crimp tools

*CD-940-DA adapter required for use with die with CT-940 tools.
**Purple CD-930H-250 die with adapter can be used in place of purple CD-940H-250 die.

HTAP Covers

• Protect HTAP connection from environment and act as insulation
• High impact, hard shell protection for HTAP applications using #14 AWG to 1000 kcmil conductors
• Made from high density, flame retardant clear polycarbonate material for maximum protection, durability, and length of life

Use

PANDUIT

low-profile series cable ties to secure cover.

Type HTCT

Type CLRCVR

H

L

W

Part Number

Main

Die Colour &

Part No.

Thickness

mm

Width  Height

Std.

Pkg.

Qty.

mm

mm

HTCT8-8-1

8-14 (8-14) code size 

(flex cable)

Green,

CD-920H-8*

15.24mm

10.2

17.5

1

HTCT6-6-1

6-10 (6-10) code size 

(flex cable)

Orange,

CD-920H-6*

15.49mm

10.2

25.1

1

HTCT2-2-1

2-6 (2-8) code size 

(flex cable)

Brown,

CD-920H-2*

19.30mm

15.5

31.8

1

HTCT250-8-1

250-2 (4/0-2) code size

(flex cable)

Purple,

CD-930H-250**

23.4mm

24.4

48.8

1

HTCT250-2-1

250-2 (4/0-2) code size

(flex cable)

Purple,

CD-930H-250**

23.4mm

24.4

48.8

1

HTCT250-250-1

250-2 (4/0-2) code size

(flex cable)

Purple,

CD-930H-250**

22.86mm

22.6

48.8

1

HTCT500-250-1

500-4/0 (350-4/0) code

size (flex cable)

Brown,

CD-940H-500

25.4mm

31.8

77

1

HTCT500-500-1

500-250 (350-4/0) code

size (flex cable

Brown,

CD-940H-500

26.67mm

31.5

62.0

1

HTCT750-4/0-1

750-350 (550-500 code

size (flex cable)

Yellow, 

CD-940H-750

25.4mm

37.8

95.3

1

HTCT750-750-1

750-500 (550-500 code

size (flex cable)

Yellow, 

CD-940H-750

32.0mm

37.1

80.3

1

HTCT1000-250-1

1000-750 (777-500) code

size (flex cable)

Yellow, 

CD-940H-1000

25.4mm

40.4

95.3

1

HTCT1000-1000-1

1000-750 (750-500) code

size (flex cable)

White,

CD-940H-1000

25.4mm

43.2

83.8

1

Part Number

For PANDUIT

H-Type Taps

Length

Width 

Height

Std.

Pkg.

Qty.

mm

mm

mm

CLRCVR1-1

HTCT8-8-1,

HTCT6-6-1

95.5

27.9

22.9

1

CLRCVR2-1

HTCT2-2-1

113.8

35.8

33

1

CLRCVR3-1

HTCT250-8-1,

HTCT250-2-1

123.2

42.2

38.1

1

CLRCVR4-1

HTCT250-250-1

123.2

54.9

38.1

1

Panduit-Pannet-html.html
background image

182

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see 

pages 192-194

Bronze Service Post Connectors

• Male - one cable
• For grounding one conductor to steel structures, bus bars

or transformers

• For tapping from bus bar

• Made from hard drawn copper rod
• UL Listed per 467 for grounding and bonding, acceptable

for direct burial in earth and concrete

Bronze Service Post Connectors

• Male - two cables
• For grounding two conductors

to steel structures, bus bars or transformers

• For tapping from

bus bar

• Made from hard drawn copper rod
• UL Listed per 467 for grounding and bonding, acceptable

for direct burial in earth and concrete

Type SP1

Type SP2

V

V

A

Part Number

Conductor Size Range

(V)

Wire Diameter

Range mm

Stud Size

mm

Nut Hex

mm

Length  (A)

Std.

Pkg.

Qty.

mm

SP1-8-C

#12 SOL – #8 STR

2.06mm - 3.71mm

6.35mm - 50.8mm

12.7mm

16.0

100

SP1-8L-C

#12 SOL – #8 STR

2.06mm - 3.71mm

6.35mm - 50.8mm

12.7mm

16.0

100

SP1-7-C

#8 SOL – #7 STR

3.25mm - 4.17mm

6.35mm - 50.8mm

17.5mm

22.4

100

SP1-7L-C

#8 SOL – #7 STR

3.25mm - 4.17mm

6.35mm - 50.8mm

17.5mm

22.4

100

SP1-4-C

#10 SOL – #4 STR

2.59mm - 5.89mm

7.93mm - 457.2mm

19.05mm

23.9

100

SP1-4L-C

#10 SOL – #4 STR

2.59mm - 5.89mm

7.93mm - 457.2mm

19.05mm

23.9

100

SP1-3-C

#6 SOL – #3 STR

4.12mm - 6.60mm

9.53mm - 406.4mm

20.6mm

26.9

100

SP1-3L-C

#6 SOL – #3 STR

4.12mm - 6.60mm

9.53mm - 406.4mm

20.6mm

26.9

100

SP1-2-C

#4 STR – #2 STR

5.89mm - 7.41mm

9.53mm - 406.4mm

22.3mm

26.9

100

SP1-2L-C

#4 STR – #2 STR

5.89mm - 7.41mm

9.53mm - 406.4mm

22.3mm

26.9

100

SP1-1/0-L

#6 SOL – 1/0 STR

4.11mm - 9.53mm

12.7mm - 330.2mm

25.4mm

33.3

50

SP1-1/0L-L

#6 SOL – 1/0 STR

4.11mm - 9.53mm

12.7mm - 330.2mm

25.4mm

33.3

50

SP1-2/0-Q

#1 SOL – 2/0 STR

7.34mm - 10.6mm

12.7mm - 330.2mm

28.7mm

36.6

25

SP1-2/0L-Q

#1 SOL – 2/0 STR

7.34mm - 10.6mm

12.7mm - 330.2mm

28.7mm

36.6

25

SP1-4/0-Q

3/0 SOL – 4/0 STR

10.41mm - 13.41mm

15.9mm - 279.4mm

35mm

42.9

25

SP1-4/0L-Q

3/0 SOL – 4/0 STR

10.41mm - 13.41mm

15.9mm - 279.4mm

35mm

42.9

25

SP1-350-12

4/0 STR – 350 kcmil

13.41mm - 17.32mm

15.9mm - 279.4mm

38.1mm

50.8

12

SP1-350L-12

4/0 STR – 350 kcmil

13.41mm - 17.32mm

15.9mm - 279.4mm

38.1mm

50.8

12

SP1-500-12

250 kcmil – 500 kcmil

14.61mm - 20.70mm

19.05mm - 254mm

45.9mm

58.7

12

SP1-500L-12

250 kcmil – 500 kcmil

14.61mm - 20.70mm

19.05mm - 254mm

45.9mm

58.7

12

Part Number Conductor Size Range (V)

Wire Diameter

Range mm

Stud Size

mm

Nut Hex

mm

Length (A)

Std.

Pkg.

Qty.

mm

SP2-8-C

#12 SOL - #8 STR

2.06mm - 3.71mm

6.35mm - 50.8mm

12.7mm

19.0

100

SP2-8L-C

#12 SOL - #8 STR

2.06mm - 3.71mm

6.35mm - 50.8mm

12.7mm

19.0

100

SP2-7-C

#10 SOL - #7 STR

2.59mm - 4.2mm

6.35mm - 50.8mm

17.5mm

25.4

100

SP2-7L-C

#10 SOL - #7 STR

2.59mm - 4.2mm

6.35mm - 50.8mm

17.5mm

25.4

100

SP2-4-C

#10 SOL - #4 STR

2.59mm - 5.89mm

7.9mm - 457.2mm

19.05mm

29.5

100

SP2-4L-C

#10 SOL - #4 STR

2.59mm - 5.89mm

7.9mm - 457.2mm

19.05mm

29.5

100

SP2-3-C

#10 SOL - #3 STR

2.59mm - 6.6mm

9.5mm - 406.4mm

20.6mm

27.7

100

SP2-3L-C

#10 SOL - #3 STR

2.59mm - 6.6mm

9.5mm - 406.4mm

20.6mm

27.7

100

SP2-2-C

#10 SOL - #2 STR

2.59mm - 6.4mm

9.5mm - 406.4mm

22.4mm

35.1

100

SP2-2L-C

#10 SOL - #2 STR

2.59mm - 6.4mm

9.5mm - 406.4mm

22.4mm

32.5

100

SP2-1/0-L

#2 SOL - 1/0 STR

6.55mm - 9.5mm

12.7mm - 330mm

25.4mm

42.9

50

SP2-1/0L-L

#2 SOL - 1/0 STR

6.55mm - 9.5mm

12.7mm - 330mm

25.4mm

42.9

50

SP2-2/0-Q

#2 SOL - 2/0 STR

6.55mm  - 106.4mm 12.7mm - 330mm

28.7mm

47.8

25

SP2-2/0L-Q

#2 SOL - 2/0 STR

6.55mm  - 106.4mm 12.7mm - 330mm

28.7mm

47.8

25

SP2-4/0-Q

#1 SOL - 4/0 STR

7.34mm - 13.4mm 15.9mm - 279.4mm 35.1mm

57.2

25

SP2-4/0L-Q

#1 SOL - 4/0 STR

7.34mm - 13.4mm 15.9mm - 279.4mm 35.1mm

57.2

25

SP2-350-12

#1 STR - 350 kcmil

8.43mm - 17.3mm 15.9mm - 279.4mm 38.1mm

68.3

12

SP2-350L-12

#1 STR - 350 kcmil

8.43mm - 17.3mm 15.9mm - 279.4mm 38.1mm

68.3

12

SP2-500-12

#3/0 STR - 500 kcmil

11.19mm - 20.7mm 19.05mm - 254mm

46mm

81.0

12

SP2-500L-12

#3/0 STR - 500 kcmil

11.19mm - 20.7mm 19.05mm - 254mm

46mm

81.0

12

Panduit-Pannet-html.html
background image

183

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

For AWG to mm

2

conversion tables see pages 192-194

Bronze Service Post Connectors

• Female - one cable
• For connecting one conductor to external studs

• For grounding to steel structures, bus bars

or transformers

Bronze Service Post Connectors

• Female - two cables
• For connecting two conductors to external threaded studs

• For grounding to steel structures, bus bars or transformers

Type SPF1

Type SPF2

A

V

V

A

Part Number

Conductor Size Range

(V)

Wire Diameter Range

mm

Stud Size

mm

Nut Hex

mm

Length

(A)

Std.

Pkg.

Qty.

mm

SPF1-8-C

#12 SOL – #8 STR

2.06mm - 3.71mm

6.35mm - 50.8mm

12.7mm

23.1

100

SPF1-7-C

#10 SOL – #7 STR

2.59mm - 4.2mm

6.35mm - 50.8mm

17.5mm

28.7

100

SPF1-4-C

#8 SOL – #4 STR

3.25mm - 5.89mm

7.93mm - 457.2mm 19.05mm

36.6

100

SPF1-3-C

#6 STR – #3 STR

4.7mm - 6.60mm

9.53mm - 406.4mm 20.06mm

38.1

100

SPF1-2-C

#6 STR – #2 STR

4.7mm - 7.42mm

9.53mm - 406.4mm

22.3mm

41.4

100

SPF1-1/0-L

#2 SOL – 1/0 STR

6.55mm - 9.5mm

12.7mm - 330.2mm

25.4mm

47.8

50

SPF1-2/0-Q

#1 SOL – 2/0 STR

7.34mm - 10.6mm

12.7mm - 330.2mm

28.7mm

52.3

25

SPF1-4/0-Q

1/0 STR – 4/0 STR

9.5mm - 13.41mm

15.9mm - 279.4mm

35mm

60.5

25

SPF1-350-12

4/0 STR – 350 kcmil

13.41mm - 17.32mm

15.9mm - 279.4mm

38.1mm

66.8

12

SPF1-500-12

300 kcmil – 500 kcmil

16.10mm - 20.7mm

19.05mm - 254mm

45.9mm

79.5

12

Part Number

Conductor Size Range

(V)

Wire Diameter

Range mm

Stud Size

mm

Nut Hex

mm

Length

(A)

Std.

Pkg.

Qty.

mm

SPF2-8-C

#12 SOL – #8 STR

2.06mm - 3.71mm

6.35mm - 50.8mm

12.7mm

28.7

100

SPF2-7-C

#10 SOL – #7 STR

2.59mm - 4.2mm

6.35mm - 50.8mm

17.5mm

36.6

100

SPF2-4-C

#10 SOL – #4 STR

2.59mm - 5.89mm

7.93mm - 457.2mm

19.05mm

39.6

100

SPF2-3-C

#10 SOL – #3 STR

2.59mm - 6.60mm

9.53mm - 406.4mm

20.06mm

41.4

100

SPF2-2-C

#10 SOL – #2 STR

2.59mm - 7.42mm

9.53mm - 406.4mm

22.3mm

49.3

100

SPF2-1/0-L

#2 SOL – 1/0 STR

6.50mm - 9.5mm

12.7mm - 330.2mm

25.4mm

54.1

50

SPF2-2/0-Q

#2 SOL – 2/0 STR

6.55mm - 10.6mm

12.7mm - 330.2mm

28.7mm

58.7

25

SPF2-4/0-Q

#1 SOL – 4/0 STR

7.34mm - 13.41mm

15.9mm - 279.4mm

35mm

63.5

25

SPF2-350-12

#1 STR – 350 kcmil

8.43mm -17.32mm

15.9mm - 279.4mm

38.1mm

68.3

12

SPF2-500-12

3/0 STR – 500 kcmil

119mm - 20.7mm

19.05mm - 254mm

45.9mm

84.1

12

Panduit-Pannet-html.html
background image

184

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

• Includes all components in

one package for complete
electrical connection

• Clear PVC heat shrink

sleeves pre-cut to length
to insulate reducing splice

• Clear PVC allows easy

visual inspection of
installed reducing splice

• UL and CSA Certified up

to 600 volts when used
with

PANDUIT

reducing

splices

• Low temperature

requirement allows
application with low
temperature heat gun

• UL 224 VW-1 flame rating,

excellent flame retardant
capability

• UL Recognized

temperature rating of
150°C, high temperature
insulating property

Type RSCK

Type RSC

T

APER

-S

PLICE

In-Line Reducer

• Manufactured from seamless, high conductivity

copper tubing

• Colour coded for identification of wire size & type,

proper crimp die selection and crimp location

• UL Listed per 486A up to 35 KV*** and 90°C 

temperature rated

• Inspection window in each barrel to visually assure full

cable insertion

• Internally beveled wire entry for easy 

cable insertion

• Electro-tin plated to inhibit corrosion

** Consult cable mfg. for voltage stress relief instructions with applications greater than 2000 volts.

L

B

FROM

B

TO

Part Number

Length (A)

Conductor

Size Reduce

From

Die Colour &

Die Index No.

Conductor

Size Reduce

To

Die Colour &

Die Index No.

Std.

Pkg.

Qty.

mm

RSC4-6-L

64.5

4 AWG

Grey P29

6 AWG

Blue P24

50

RSC2-6-Q

66.5

2 AWG

Brown P33

6 AWG

Blue P24

25

RSC2-4-Q

63.5

2 AWG

Brown P33

4 AWG

Grey P29

25

RSC1/0-6-X

71.4

1/0 AWG

Pink P42

6 AWG

Blue P24

10

RSC1/0-4-X

68.6

1/0 AWG

Pink P42

4 AWG

Grey P29

10

RSC2/0-6-X

75.9

2/0 AWG

Black P45

6 AWG

Blue P24

10

RSC2/0-4-X

73.2

2/0 AWG

Black P45

4 AWG

Grey P29

10

RSC4/0-6-X

82.3

4/0 AWG

Purple P54

6 AWG

Blue P24

10

RSC4/0-4-X

79.2

4/0 AWG

Purple P54

4 AWG

Grey P29

10

RSC750-4/0-6

118.36

750 kcmil

Black P106

4/0 AWG

Purple P54

6

RSC750-X4/0-6

115.3

750 kcmil

Black P106

4/0 Flex

Yellow P62

6

RSC750-X350-6

113.0

750 kcmil

Black P106

350 Flex

Blue P76

6

RSCX750-4/0-3

128.0

750 Flex

Orange P107

4/0 AWG

Purple P54

3

RSCX750-750-3

114.3

750 Flex

Orange P107

750 kcmil

Black P106

3

Part Number

Kit Contents

Std.

Pkg.

Qty.

RSCK4-6-1

1 pc.  RSC4-6-L copper compression in-line reducing splice
1 pc.  HSTTPN50-713-Q crystal clear PVC heat shrink 12.7mm x 181mm long

1

RSCK2-6-1

1 pc.  RSC2-6-Q copper compression in-line reducing splice
1 pc.  HSTTPN62-750-Q crystal clear PVC heat shrink 15.9mm x 190.5mm long

1

RSCK2-4-1

1 pc.  RSC2-4-Q copper compression in-line reducing splice
1 pc.  HSTTPN62-750-Q crystal clear PVC heat shrink 15.9mm x 190.5mm long

1

RSCK1/0-6-1

1 pc.  RSC1/0-6-X copper compression in-line reducing splice
1 pc.  HSTTPN75-775-Q crystal clear PVC heat shrink 15.9mm x 196.9mm long
1 pc.  HSTTPN50-438-L crystal clear PVC heat shrink 12.7mm x 111.1mm long

1

RSCK1/0-4-1

1 pc.  RSC1/0-4-X copper compression in-line reducing splice
1 pc.  HSTTPN75-775-Q crystal clear PVC heat shrink 15.9mm x 196.9mm long
1 pc.  HSTTPN50-438-L crystal clear PVC heat shrink 12.7mm x 111.1mm long

1

RSCK2/0-6-1

1 pc.  RSC2/0-6-X copper compression in-line reducing splice
1 pc.  HSTTPN75-775-Q crystal clear PVC heat shrink 15.9mm x 196.9mm long
1 pc.  HSTTPN50-438-L crystal clear PVC heat shrink 12.7mm x 111.1mm long

1

RSCK2/0-4-1

1 pc.  RSC2/0-4-X copper compression in-line reducing splice
1 pc.  HSTTPN75-775-Q crystal clear PVC heat shrink 15.9mm x 196.9mm long
1 pc.  HSTTPN50-438-L crystal clear PVC heat shrink 12.7mm x 111.1mm long

1

RSCK4/0-6-1

1 pc.  RSC4/0-6-X copper compression in-line reducing splice
1 pc.  HSTTPN100-775-Q crystal clear PVC heat shrink 25.4mm x 196.9mm long
1 pc.  HSTTPN50-438-L crystal clear PVC heat shrink 12.7mm x 111.1mm long

1

RSCK4/0-4-1

1 pc.  RSC4/0-4-X copper compression in-line reducing splice
1 pc.  HSTTPN100-775-Q crystal clear PVC heat shrink 25.4mm x 196.9mm long
1 pc.  HSTTPN50-438-L crystal clear PVC heat shrink 12.7mm x 111.1mm long

1

RSCK750-4/0-1

1 pc.  RSC750-4/0-6 copper compression in-line reducing splice
1 pc.  HSTTPN150-925-X crystal clear PVC heat shrink 38.1mm x 235mm long
1 pc.  HSTTPN100-775-Q crystal clear PVC heat shrink 25.4mm x 196.9mm long

1

RSCK750-X4/0-1

1 pc.  RSC750-X4/0-6 copper compression in-line reducing splice
1 pc.  HSTTPN150-925-X crystal clear PVC heat shrink 38.1mm x 235mm long

1

RSCK750-X350-1

1 pc.  RSC750-X350-6 copper compression in-line reducing splice
1 pc.  HSTTPN150-925-X crystal clear PVC heat shrink 38.1mm x 235mm long

1

RSCKX750-4/0-1

1 pc.  RSCX750-4/0-3 copper compression in-line reducing splice
1 pc.  HSTTPN200-950-X crystal clear PVC heat shrink 50.8mm x241.3mm long
1 pc.  HSTTPN100-775-Q crystal clear PVC heat shrink 25.4mm x196.9mm long

1

RSCKX750-750-1

1 pc.  RSCX750-750-3 copper compression in-line reducing splice
1 pc.  HSTTPN200-950-X crystal clear PVC heat shrink 50.8mm x 241.3mm

1

T

APER

-S

PLICE

Kits

Panduit-Pannet-html.html
background image

185

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

For AWG to mm

2

conversion tables see pages 192-194

Bronze Grounding Clamps – U-Bolt Style

• Joins copper cable parallel or at a right angle to a rod, tube or pipe

A

Type GPL

Type KP

Bronze Grounding Pipe Clamps

• Grounds copper conductors to water pipe or copper tube
• Cast from high strength bronze

• Screws plated for corrosion resistance
• CSA Certified and UL Listed per UL 467 for

ground and bonding

L

W

Part Number

Accommodates

Conductor Size Range

Wire Diameter

Range mm

Length (A)

Std.

Pkg.

Qty.

Rod

IPS

mm

GPL-4-Q

5/8 or 3/4

9.5mm

#8 SOL – #4 STR

3.25mm - 5.89mm

50.8

25

GPL-5-Q

5/8 or 3/4

9.5mm

#4 SOL – 2/0 STR

5.18mm - 10.6mm

50.8

25

GPL-6-Q

5/8 or 3/4

9.5mm

2/0 SOL – 250 kcmil

9.3mm - 14.6mm

50.8

25

GPL-8-Q

7/8 or 1

#8 SOL – #4 STR

3.25mm - 5.89mm

60.5

25

GPL-9-Q

7/8 or 1

#4 SOL – 2/0 STR

5.18mm - 10.6mm

60.5

25

GPL-10-Q

7/8 or 1

2/0 SOL – 250 kcmil

9.3mm - 14.6mm

60.5

25

GPL-14-X

25.4mm

#8 SOL – #4 STR

3.25mm - 5.89mm

66.8

10

GPL-15-X

25.4mm

#4 SOL – 2/0 STR

5.18mm - 10.6mm

66.8

10

GPL-16-X

25.4mm

2/0 SOL – 250 kcmil

9.3mm - 14.6mm

66.8

10

GPL-20-X

31.8mm

#8 SOL – #4 STR

3.25mm - 5.89mm

76.2

10

GPL-21-X

31.8mm

#4 SOL – 2/0 STR

5.18mm - 10.6mm

76.2

10

GPL-22-X

31.8mm

2/0 SOL – 250 kcmil

9.3mm - 14.6mm

76.2

10

GPL-26-X

38.1mm

#8 SOL – #4 STR

3.25mm - 5.89mm

82.6

10

GPL-27-X

38.1mm

#4 SOL – 2/0 STR

5.18mm - 10.6mm

82.6

10

GPL-28-X

38.1mm

2/0 SOL – 250 kcmil

9.3mm - 14.6mm

82.6

10

GPL-32-3

50.8mm

#8 SOL – #4 STR

3.25mm - 5.89mm

95.3

3

GPL-33-3

50.8mm

#4 SOL – 2/0 STR

5.18mm - 10.6mm

95.3

3

GPL-34-3

50.8mm

2/0 SOL – 250 kcmil

9.3mm - 14.6mm

95.3

3

GPL-39-3

63.5mm

#4 SOL – 2/0 STR

5.18mm - 10.6mm

107.9

3

GPL-40-3

63.5mm

2/0 SOL – 250 kcmil

9.3mm - 14.6mm

107.9

3

GPL-44-1

76.2mm

#8 SOL – #4 STR

3.25mm - 5.89mm

120.6

1

GPL-45-1

76.2mm

#4 SOL – 2/0 STR

5.18mm - 10.6mm

120.6

1

GPL-46-1

76.2mm

2/0 SOL – 250 kcmil

9.3mm - 14.6mm

120.6

1

GPL-51-1

88.9mm

#4 SOL – 2/0 STR

5.18mm - 10.6mm

133.4

1

GPL-52-1

88.9mm

2/0 SOL – 250 kcmil

9.3mm - 14.6mm

133.4

1

GPL-57-1

101.6mm

#4 SOL – 2/0 STR

5.18mm - 10.6mm

146.0

1

GPL-58-1

101.6mm

2/0 SOL – 250 kcmil

9.3mm - 14.6mm

146.0

1

Part Number

Water Pipe Range

mm

Conductor Range Tap

Wire Diameter

Range mm

Length

Width 

Std.

Pkg.

Qty.

mm

mm

KP1-C

12.7mm - 25.4mm

#10 SOL - #2 STR

2.59mm - 7.42mm

57.9

16.8

100

KP2-L

31.8mm - 50.8mm

#10 SOL - #2 STR

2.59mm - 7.42mm

90.9

18.5

50

12.7mm or 19.05mm

12.7mm or 19.05mm

12.7mm or 19.05mm

Panduit-Pannet-html.html
background image

186

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see pages 192-194

Heavy Duty Crimp Tool - Hand Operated 

• Available with or without control cycle feature
• Develops 6 tons of crimping force
• Cushioned grips

• Fast die change-over uses single retention screw
• Colour coded crimp dies
• Embosses die index number on crimp connector

CT-720 shown with CC-720

controlled cycle mechanism

(standard with CT-720-7CC &

CT-720-3CC kit)

Dies for CT-720

• Colour coded
• Embosses die index number on

properly installed crimps

Part Number

Part Description

Std.

Pkg.

Qty.

CT-720

Manual crimping tool for UL Listed or Recognized and CSA Certified
terminations of 

PANDUIT

P

AN

-L

UG

copper compression lugs and

splices for #8 AWG – 500 kcmil copper code conductor and aluminium
compression lugs and splices for #6 AWG – 350 kcmil copper and
aluminum code conductors.  Provides UL Listed terminations of

PANDUIT P

AN

-T

ERM

#8 – #2 AWG vinyl insulated terminals.

Colour coded CD-720 crimp dies, carrying/storage case and controlled-
cycle mechanism must be purchased separately.

Specifications:
Output:  6.09 tonnes
Weight:  3.5kg
Length:  660.4mm
Handle span:  1473.2mm  (open), 63.5mm (closed)
Warranty:  90 days

1

CC-720

Optional control cycle mechanism only.  
Total weight of tool with CC-720 is 3.75kg

1

Part Number

Used to Install PANDUIT

Compression Connector Sizes:

Copper

Std.

Pkg.

Qty.

CD-720-1

#8 – #2 AWG

1

CD-720-2

#1 – 3/0 AWG

1

CD-720-3

4/0 – 250 kcmil

1

CD-720-4

300 kcmil

1

CD-720-5

350 kcmil

1

CD-720-6

400 kcmil

1

CD-720-7

500 kcmil

1

CD-720PV8-2

#8 - #2 AWG vinyl insulated 

P

AN

-T

ERM

terminals

1

Panduit-Pannet-html.html
background image

187

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

For AWG to mm

2

conversion tables see pages 192-194

Kits for CT-720

Includes tool, crimp dies and

carrying case

C

ONTOUR

C

RIMP

Controlled-Cycle Crimp Tools

• Specifically designed for the installation of 

P

AN

-T

ERM

terminals, disconnects and splices

• Ergonomically designed to reduce stress in hand and wrist

CT-1550

CT-1551

CT-1570

C

ONTOUR

C

RIMP

Controlled Cycle Crimp Tool

• Ergonomically designed to dramatically reduce stress in

hand and wrist

• Controlled cycle crimp mechanism assures a full crimp

cycle for reliable terminations

• Built-in ratchet device is releasable for added safety
• Emergency mid-cycle release

CT-1700

Part Number

Part Description

Kit Contents

Std.

Pkg.

Qty.

CT-720-7

Basic tool kit with seven dies.

Includes:

• Seven dies (CD-720-1 – 7) for

installing #8 AWG – 500 kcmil
copper compression connectors

• Carrying/storage case (C-720)

1

CT-720-7CC

Controlled cycle tool kit with seven
dies.  Controlled cycle mechanism
factory installed on crimping tool.

Includes:

• Seven dies (CD-720-1 – 7) for

installing #8 AWG – 500 kcmil
copper compression connectors

• Carrying/storage case (C-720)

1

CT-720-3

Basic tool kit with three dies.

Includes:

• Three dies (CD-720-1 – 3) for

installing #8 AWG – 250 kcmil
copper compression connectors

• Carrying/storage case (C-720)

1

CT-720-3CC

Controlled cycle tool kit with three
dies.  Controlled cycle mechanism
factory installed on crimping tool.

Includes:

• Three dies (CD-720-1 – 3) for

installing #8 AWG – 250 kcmil
copper compression connectors

• Carrying/storage case (C-720)

1

C-720

Steel carrying case for CT-720
crimping tool.

1

Part Number

Part Description

Std.

Pkg.

Qty.

CT-1700

Crimps

PANDUIT

#8 – #2 AWG non-insulated tubular terminals 

(S series), #8 – #1 AWG copper lugs and splices, #6 – #4 AWG
aluminum lugs and splices, and CTAPF copper taps for #14 – #3 AWG.
Includes 5 position, colour coded rotating die.

1

CT-1701

Crimps

PANDUIT

#10 – #2 AWG non-insulated large gauge ring

terminal (P series). Crimps #8 – #1 AWG copper lugs and splices, and #6
– #4 AWG aluminum lugs and splices, and #14 – #3 AWG CTAPF copper
taps.   Includes 5 position rotating die.

1

Part Number

Part Description

Std.

Pkg.

Qty.

CT-1550

Crimps

PANDUIT

#22 – #10 AWG nylon and vinyl insulated terminals,

splices and disconnects.  The CT-1550 has the red/blue pocket closest to
the pivot which provides a reduced crimp effort for those who make
red/blue terminations.

1

CT-1551

Crimps

PANDUIT

#22 – #10 AWG nylon and vinyl insulated terminals,

splices and disconnects. The CT-1551 has the yellow pocket closest to
the pivot which provides a reduced crimp effort for those who make
yellow terminations.

1

CT-1570

Crimps

PANDUIT

#22 – #10 AWG and .5-6.0 mm non-insulated

terminals and disconnects. Crimps  

PANDUIT

#22 – #10 AWG and 

.5-6.0 mm non-insulated splices, and #10 AWG compression lugs.

1

Panduit-Pannet-html.html
background image

188

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see pages 192-194

Controlled Cycle Hydraulic Crimp Tool

• Generates 14 tons of crimping force
• Two-stage rapid ram advance; connectors can be held in

die set while conductor is inserted 

• Audible “click” when cycle is complete

• Fast die changeover
• Tool head rotates for ease of installation
• Recalibration capability for quality control programs

Crimp Dies - CD-920

• Colour coded 2-piece die sets
• Interchangeable on CT-920, CT-2920, CT-930, CT-920CH,

CT-930CH, CT-940CH with CD-940-DA adapter

• Embossed die index number when crimped with

PANDUIT

tool

Part Number

Part Description

Std.

Pkg.

Qty.

CT-930

Terminates 

PANDUIT

P

AN

-L

UG

Compression Connectors:

• Copper compression lugs and splices for #8 AWG – 750 kcmil code

conductor

• Copper compression lugs and splices for #8 AWG – 600 kcmil flex

conductor

• Copper compression CTAPF taps for #10 AWG – 3/0 AWG code

conductor

• Copper compression CTAP taps for #8 AWG – 4/0 AWG code conductor

• Copper compression HTCT taps for #14 AWG – 250 kcmil code

conductor, #14 AWG – 4/0 AWG flex conductor

• Aluminum compression lugs and splices for #6 AWG – 600 kcmil code

conductor

• Aluminum compression HTAPS for #14 AWG – 500 kcmil code conductor

PANDUIT P

AN

-T

ERM

Tubular Terminals for #8 AWG – 250 kcmil code

conductor

Specifications:
Output:  14.22 tonnes
Jaw Opening:  41.91mm
Weight:  7.5kg
Length:  635mm
Handle Span:  190.5mm (open), 152.4mm (closed)
Warranty:  5 years

CT-930 includes:
• Tool
• Plastic tool case with die storage

1

Part Number

Used to Install PANDUIT

Compression Lug & Splice Sizes

Std.

Pkg.

Qty.

Copper

Conductor Size

Code

Copper

Die Colour & No.

Aluminium

Conductor Size

Code

Aluminium

Die Colour & No.

CD-920-8

#8 AWG

Red P21

1

CD-920-6

#6 AWG

Blue P24

1

CD-920-4

#4 AWG

Grey P29

#6 AWG

Grey P29

1

CD-920-2

#2 AWG

Brown P33

1

CD-920-1

#1 AWG

Green P37

#4 AWG

Green P37

1

CD-920-1/0

1/0 AWG

Pink P42

#2 AWG

Pink P42

1

CD-920-2/0

2/0 AWG

Black P45

#1 AWG

Gold P45

1

CD-920-3/0

3/0 AWG

Orange P50

1/0 AWG

Tan P50

1

CD-920-4/0

4/0 AWG

Purple P54

2/0 AWG

Olive P54

1

CD-920-250

250 kcmil

Yellow P62

3/0 AWG

Ruby P62

1

CD-920-300

300 kcmil

White P66

4/0 AWG

White P66

1

CD-920-350

350 kcmil

Red P71

250 kcmil

Red P71

1

CD-920-400

400 kcmil

Blue P76

300 kcmil

Blue P76

1

CD-920-500

500 kcmil

Brown P87

350 kcmil

Brown P87

1

CD-920-600

600 kcmil

Green P94

400 kcmil

Green P94

1

CD-920-500A

500 kcmil flex, 600

kcmil flex

Pink P99

500 kcmil

Pink P99

1

CD-920-750

750 kcmil

Black P106

600 kcmil

Black P106

1

Panduit-Pannet-html.html
background image

189

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

For AWG to mm

2

conversion tables see pages 192-194

Hydraulic Crimp Tool, Dieless 

• Generates 6.2 tons of crimping force
• 2-stage hydraulic pump
• No need to fully retract indenters

• Light weight and portable
• Wire range taking capability

Part Number

Part Description

Std.

Pkg.

Qty.

CT-980

Manual hydraulic

UNI-DIE

dieless crimping tool provides UL Listed or

Recognised and CSA Certified terminations of 

PANDUIT

P

AN

-L

UG

copper compression lugs and splices for #4 AWG – 750 kcmil copper
code conductor.  Terminates 

P

AN

-L

UG

aluminium compression lugs and

splices for #6 AWG – 500 kcmil copper and aluminium code conductor
(not UL or CSA).

Specifications

:

Output:  6.3 tonnes
Jaw opening:  37.08mm
Weight:  4.77kg
Length:  330mm
Height:  304.8mm
Width:  16.2mm
Handle span:  381mm (open), 146.05mm (closed)
Warranty:  5 years

CT-980 includes:
• Tool
• Plastic tool case

1

Panduit-Pannet-html.html
background image

190

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For AWG to mm

2

conversion tables see pages 192-194

Ring Terminal Nylon Insulated

• Metal insulation grip sleeve for high vibration or conductor

strain environments

• Colour-coded insulation sleeve identifies wire range by

using industry standard colours. Provides quick visual
identification of intended range of wires

W

A

Ring Terminal Nylon Insulated - Expanded Insulation

• Expanded wire entry allows for large O.D. wire insulation

or multiple wire crimps within one wire barrel

• Metal insulation grip sleeve for high vibration or conductor

strain environments

• Colour-coded insulation sleeve identifies wire range by

using industry standard colours. Provides quick visual
identification of intended range of wires

• Colour: Yellow

The following installation tool may be used: CT-100 only.

W

A

The following installation tools may be used: CT-100, CT-600, CT-1550 and CT-1551. 
CT-1550 and CT-1551 can be found on page 29.

Part Number

Wire Range

Colour

Stud Size

mm

Length (A) Width (W)

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

PN18-12R-C

22-18 AWG

Red

12.7mm

34.3

18.3

100

500

PN14-12R-L

16-14 AWG

Blue

12.7mm

34.3

18.3

50

500

PN10-10R-L

12-10 AWG

Yellow

#10

27.4

9.7

50

500

PN10-14R-L

12-10 AWG

Yellow

6.35mm

31.2

13.2

50

500

PN10-56R-L

12-10 AWG

Yellow

7.9mm

31.2

13.2

50

500

PN10-38R-L

12-10 AWG

Yellow

9.5mm

33.3

14.7

50

500

PN10-12R-L

12-10 AWG

Yellow

12.7mm

37.3

18.3

50

500

Part Number

Wire Range

Stud Size

mm

Length (A)

Width (W)

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

PN10-10RX-L

12-10 AWG

#10

28.7

9.40

50

500

PN10-14RX-L

12-10 AWG

6.35mm

32.3

13.2

50

500

PN10-56RX-L

12-10 AWG

7.9mm

32.3

13.2

50

500

PN10-38RX-L

12-10 AWG

9.5mm

34.3

14.7

50

500

Panduit-Pannet-html.html
background image

191

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

For AWG to mm

2

conversion tables see pages 192-194

Ring Terminal Vinyl Insulated - Funnel Entry

• Funnel entry speeds wire insertion for faster assembly

and lower installed costs

• Insulation support provides strain relief of the terminal

and helps to prevent wire damage if wire is subject to a 
bending application

• Industry standard colour coding to indicate wire range
• Brazed seam assures a reliable crimp

The following installation tools may be used:  CT-100, CT-600, CT-1550 and CT-1551. 
CT-1550 and CT-1551 can be found on page 29.

W

A

Ring Terminal Vinyl Insulated - Expanded Insulation

• Expanded wire entry allows for large O.D. wire insulation or

multiple wire crimps within one wire barrel

• Industry standard colour coding to indicate wire range

• Brazed seam assures a reliable crimp
• Insulation support
• Colour:  Yellow

The following installation tool may be used: CT-100 only.

W

A

Ring Terminal Non-Insulated

• Brazed seam assures a reliable crimp
• Internally bevelled for easy wire insertion

• Extended length is easier to crimp and assures good 

quality wire contact

The following installation tools may be used: CT-100, CT-200, CT-600 and CT-1570. 
CT-1570 can be found on page 29.

A

W

Part Number

Wire Range

Colour

Stud Size

mm

Length (A) Width (W)

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

PV18-12R-C

22-18 AWG

Red

12.7mm

36.1

18.3

100

500

PV14-12R-L

16-14 AWG

Blue

12.7mm

36.1

18.3

50

500

PV10-10R-L

12-10 AWG

Yellow

#10

26.7

7.87

50

500

PV10-14R-L

12-10 AWG

Yellow

6.35mm

31.2

13.2

50

500

PV10-56R-L

12-10 AWG

Yellow

7.9mm

31.2

13.2

50

500

PV10-38R-L

12-10 AWG

Yellow

9.5mm

33.3

14.7

50

500

PV10-12R-L

12-10 AWG

Yellow

12.7mm

37.1

18.3

50

500

Part Number

Wire Range

Stud Size

mm

Length (A)

Width (W)

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

PV10-10RX-L

12-10 AWG

#10

27.9

7.90

50

500

PV10-14RX-L

12-10 AWG

6.35mm

32.8

13.2

50

500

PV10-56RX-L

12-10 AWG

7.9mm

32.8

13.2

50

500

PV10-38RX-L

12-10 AWG

9.5mm

35.3

14.7

50

500

Part Number

Wire Range

Stud Size

Length (A)

Width (W)

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

P18-12R-C

22-18 AWG

12.7mm

30.5

18.3

100

1000

P14-12R-L

16-14 AWG

12.7mm

30.5

18.3

50

500

P10-10R-L

12-10 AWG

#10

20.6

9.70

50

500

P10-14R-L

12-10 AWG

6.35mm

24.4

13.2

50

500

P10-56R-L

12-10 AWG

7.9mm

24.4

13.2

50

500

P10-38R-L

12-10 AWG

9.5mm

26.4

14.7

50

500

P10-12R-L

12-10 AWG

12.7mm

30.5

18.3

50

500

Panduit-Pannet-html.html
background image

1

.036

.81

.005

92

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

.002

.25

97

.002

.36

159

.005

.53

250

.016

.41

256

.006

.48

278

.004

.51

304

.003

.58

384

AWG

Metric

mm

2

Conductor

mm

In.

Diameter

Individual Strands

mm

Circ.

MILS

Diameter

Overall Conductor Size

Area

.05

.05

.13

.41

.16

.10

.08

25

41

10

1

7

19

41

.010

.014

.021

.016

.019

.020

.023

In.

AWG

Conductor

Metric

mm

2

0.05

0.06

26

1.0

No. of

Strands

mm

Individual Strands

Diameter

.25

1.13

.20

.43

.29

.16

.25

.010

.044

.008

.017

.011

.006

.010

In.

mm

In.

1.30

1.13

1.30

1.30

1.47

1.50

1.50

Overall Conductor Size

Diameter

.051

.044

.051

.051

.058

.059

.059

1841

1979

1984

2006

2426

2580

2600

Circ.

MILS

Area

.006

.58

397

.020

.51

400

.008

.61

448

.005

.61

475

.003

.65

484

.002

.65

496

.004

.65

496

.16

.51

.20

.13

.07

.05

.10

10

1

7

19

65

128

32

.023

.020

.024

.024

.026

.026

.026

24

16

1

105

*7

30

21

189

7

1.30

.13

.51

.25

.30

.10

.52

.051

.005

.020

.010

.012

.004

.020

1.30

1.50

1.52

1.70

1.60

1.90

1.60

.051

.059

.060

.067

.063

.075

.063

2601

2625

2828

2906

2930

2930

2934

1.5

0.25

.006

.65

556

.16

14

.026

1

1.38

.054

1.38

.054

2952

.025

.64

625

.006

.76

635

.005

.76

650

.010

.76

700

.006

.79

754

.004

.80

744

.002

.80

752

1

16

26

7

19

48

194

.025

.030

.030

.030

.031

.031

.031

14

19

1

32

7

19

65

*26

.16

.36

1.63

.25

.64

.25

.67

.006

.014

.064

.010

.025

.010

.026

1.85

1.85

1.63

1.85

1.85

2.20

2.10

.073

.073

.064

.073

.073

.087

.083

3786

3831

4096

4100

4481

4844

4871

.003

.80

760

.011

.80

791

.008

.80

820

.006

.80

833

.012

.90

977

.008

.90

992

.031

.80

992

.07

.27

.21

.16

.30

.20

.80

100

7

12

21

7

16

1

.031

.031

.031

.031

.035

.035

.031

0.38

2.5

35

315

1

19

*65

165

1

.30

.10

1.78

.45

.25

.16

2.06

.012

.004

.070

.018

.010

.006

.081

2.20

2.20

1.78

2.36

2.41

2.41

2.06

.087

.087

.070

.093

.095

.095

.081

4883

4883

4911

6088

6500

6549

6561

12

0.5

.010

.89

1000

.25

*10

.035

*7

.81

0.32

2.44

.096

7168

.64

.16

.13

.25

.16

.10

.05

45

19

1

*41

*7

50

7

.032

1024

.91

1025

.006

.91

1032

.013

.97

1111

.008

.94

1216

41

26

*7

19

.032

.036

.038

.037

.30

2.26

.10

.52

.40

.012

.089

.004

.020

.016

3.10

2.26

3.00

2.70

2.92

.122

.089

.118

.106

.115

7812

7917

7921

7963

9354

.015

1.10

1485

.008

1.20

1488

.039

1.00

1550

.010

1.19

1600

.040

1.02

1600

.005

1.19

1625

.006

1.19

1627

.37

.20

1.00

.25

1.02

.13

.16

7

24

1

*16

1

65

41

.043

.047

.039

.047

.040

.047

.047

20

10

49

*7

1

*105

84

756

1

.36

.98

2.59

.25

.30

.10

2.76

.014

.039

.102

.010

.012

.004

.109

2.95

2.95

2.59

2.95

3.50

3.70

2.76

.116

.116

.102

.116

.138

.146

.109

9880

10376

10404

10500

11718

11718

11807

6.0

18

.016

1.22

1770

.40

*7

.048

7

1.05

0.41

3.20

.126

11962

.81

.13

.16

.32

.20

56

1

511

19

37

.010

1.24

1900

.25

19

.049

19

.64

0.25

3.30

.130

12063

22

0.75

4.0

This chart details the different conductors commonly used in the industry. For
each size, either AWG or Metric, various stranding options are listed. Typically the
higher stranding is used in applications requiring greater conductor flexibility. 

AWG to Metric Wire Crosses

AWG

Metric (mm

2

)

26-22

0.1-0.5

22-18

0.5-1.0

16-24

1.5-2.5

12-10

4.0-6.0

Common Conductor Sizes and Strandings Reference Chart

No. of

Strands

No. of

Strands

Panduit-Pannet-html.html
background image

3/0

70

1/0

50

1

35

3

5

6

7

10

8

4/0

250

kcmil

150

185

240

300

93

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

.042

3.21

11840

.109

2.77

11840

.0432

3.3

13000

.1144

2.91

13090

.1285

3.25

16510

.0486

3.7

16510

.054

4.12

19740

AWG

Metric

mm

2

Conductor

mm

In.

Diameter

Individual Strands

mm

Circ.

MILS

Diameter

Overall Conductor Size

Area

.107

2.77

1.1

2.91

3.26

1.23

1.37

7

1

7

1

1

7

7

.126

.109

.13

.114

.128

.146

.162

In.

AWG

Conductor

Metric

mm

2

6

9

120

No. of

Strands

mm

19

37

19

37

37

37

37

Individual Strands

Diameter

2.57

1.83

2.89

2.06

2.07

2.29

2.47

.101

.072

.1055

.081

.0822

.09

.0973

In.

mm

In.

12.8

12.5

13.4

14.4

14.6

16

17.3

Overall Conductor Size

Diameter

.505

.504

.528

.567

.575

.63

.681

187500

187500

211600

237.8

kcmil

250

kcmil

300

kcmil

350

kcmil

Circ.

MILS

Area

.141

3.58

19740

.0545

4.15

20520

.1443

3.67

20520

.0612

4.66

26240

.162

4.11

26240

.008

5.13

31580

.0688

5.24

33090

3.58

1.38

3.67

1.55

4.11

1.73

1.75

1

7

1

7

1

7

7

.141

.164

.144

.184

.162

.204

.206

500

kcmil

37

37

37

61

37

61

61

2.54

2.64

2.9

2.26

2.95

2.3

2.51

1

.104

.114

.089

.1162

.0905

.099

17.8

18.5

20.3

20.3

20.7

20.7

22.6

.7

.728

.798

.801

.813

.814

.891

365.1

kcmil

400

kcmil

473.6

kcmil

473.6

kcmil

500

kcmil

500

kcmil

592.1

kcmil

400

16

.0772

5.88

41740

1.96

7

.232

61

2.52

.0992

22.7

.893

600

kcmil

.085

6.48

49340

.052

6.6

49340

.0867

6.61

52620

.0974

7.42

66300

.1

7.62

69070

.001

7.75

69070

.0064

8.43

83690

7

19

7

7

7

19

19

.255

.026

.026

.292

.300

.305

.332

1000
kcmil

2.72

2.82

2.31

2.9

2.91

2.38

3.25

.1071

.1109

.0908

.114

.1145

.0938

.128

24.5

25.4

25.4

26.1

26.2

26.2

28.3

.964

.998

.998

1.026

1.031

1.032

1.152

700

kcmil

750

kcmil

750

kcmil

798.4

kcmil

800

kcmil

800

kcmil

986.8

kcmil

.073

9.27

98680

.0745

9.46

105000

.0837

10.6

133100

.086

10.9

138100

.094

11.9

167800

.0673

12

167800

1.85

1.59

2.13

2.18

2.59

1.71

19

19

19

19

19

36

.365

.373

.419

.43

.47

.471

625

91

91

2.66

2.97

.1048

.117

29.3

32.7

1.153

1.287

1000
kcmil

1233.7

kcmil

2.16

1.32

2.2

2.47

2.54

1.55

1.5

61

61

91

61

61

91

61

Common Conductor Sizes and Strandings Reference Chart (continued)

500

800

kcmil

750

kcmil

600

kcmil

400

kcmil

350

kcmil

300

kcmil

95

25

2

2/0

700

kcmil

4

This chart details the different conductors commonly used in the industry. For
each size, either AWG or Metric, various stranding options are listed. Typically the
higher stranding is used in applications requiring greater conductor flexibility. 

AWG to Metric Wire Crosses

AWG

Metric (mm

2

)

26-22

0.1-0.5

22-18

0.5-1.0

16-24

1.5-2.5

12-10

4.0-6.0

No. of

Strands

Panduit-Pannet-html.html
background image

194

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Equivalent Tables
Decimal/Inches/Millimeters

1/64

1/32

3/64

1/16

5/64

3/32

7/64

1/8

9/64

5/32

11/64

3/16

13/64

7/32

15/64

1/4

.0156

0,396

0.312

0,792

.468

1,189

.0625

1,588

.0781

1,984

.0937

2,380

.1093

2,779

.125

3,175

.1406

3,571

.1562

3,968

.1718

4,366

.1875

4,763

.2031

5,159

.2187

5,555

.2343

5,954

.25

6,350

17/64

9/32

19/64

5/16

21/64

11/32

23/64

3/8

25/64

13/32

27/64

7/16

29/64

15/32

31/64

1/2

.2656

6,746

.2812

7,143

.2968

7,541

.3125

7,938

.3281

8,337

.3437

8,730

.3593

9,129

.375

9,525

.3906

9,921

.4062

10,317

.4218

10,716

.4375

11,113

.4531

11,509

.4687

11,905

.4843

12,304

.5

12,700

33/64

17/32

35/64

9/16

37/64

19/32

39/64

5/8

41/64

21/32

43/64

11/16

45/64

23/32

47/64

3/4

.5156

13,100

.5312

13,492

.5468

13,891

.5625

14,288

.5781

14,684

.5937

15,080

.6093

15,479

.625

15,875

.6406

16,271

.6562

16,667

.6718

17,066

.6875

17,463

.7031

17,859

.7187

18,255

.7343

18,654

.75

19,050

49/64

25/32

51/64

13/16

53/64

27/32

55/64

7/8

57/64

29/32

59/64

15/16

61/64

31/32

63/64

1

.7656

19,446

.7812

14,842

.7968

20,241

.8125

20,637

.8281

21,034

.8437

21,480

.8593

21,828

.875

22,225

.8906

22,620

.9062

23,017

.9218

23,416

.9375

23,810

.9531

24,208

.9687

24,605

.9843

25,001

1.

25,400

Stud Size Chart (Inches)

Standard Stud Size

Stud Size Decimal
Equivalent

Stud Size Designation in
PANDUIT™ Part Number

Terminal Hole Diameter

#2

.086”

.090”

2

#4

.112”

.118”

4

#5

.127”

.127”

5

#6

.138”

.146”

6

#8

.164”

.173”

8

#10

.190”

.204”

10

1/4”

.250”

.270”

14

5/16”

.312”

.343”

56

3/8”

.375”

.392”*

.406”**

38

7/16”

.438”

.456”

76

Standard Stud Size

Stud Size Decimal
Equivalent

Stud Size Designation in
PANDUIT™ Part Number

Terminal Hole Diameter

1/2”

.500”

.531”

12

5/8”

.625”

.656”

58

3/4”

.750”

.810”

34

7/8”

.875”

.906”

78

1”

1.00”

1031”

1

*Terminal Stud.
**Power Connector Stud.

Panduit-Pannet-html.html
background image

195

F

IBER

R

UNNER

R

OUTING

S

YSTEMS

The

PANDUIT

Network Connectivity Group provides innovative solutions for routing fibre optic  and

high performance copper cabling to and between equipment racks within a telecommunications room

or service provider facility. Routing products such as the 

F

IBER

R

UNNER

Routing System are 

critical factors in your ability to quickly install,easily  implement moves, adds and changes and maintain

the integrity of your fibre  and copper cabling plant in order to maximise long-term performance.

Robust, large capacity 12x4 and 6x4 systems for use
with large cable counts and 4x4 and 2x2 systems for
use with smaller cable counts

Hinged channel cover and split fitting covers protect
cabling and provide access for future cabling
revisions and additions

No bolts need to be tightened and no tools are
required when installing the 

Q

UIK

L

OCK

coupler

Q

UIK

L

OCK

couplers and brackets take less than five

seconds to make a mechanically secure connection  

Q

UIK

L

OCK

brackets attach system components to

ladder rack, strut, equipment racks, walls and raised
floor pedestals

Fittings provide minimum 50.8mm bend radius to
protect against signal loss due to excessive
cable bends

Multiple spillout options provide versatility to
make transitions to various equipment and
rack configurations

Compatible with 

PANDUIT F

IBRE

-D

UCT

4x4 and 2x2

Routing Systems, cable management products
and racks

The 

F

IBER

R

UNNER

12x4, 6x4, 4x4 and 2x2 Routing Systems are comprised of channel, fittings and

brackets designed to segregate, route and protect fibre optic and high performance copper cabling.

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

196

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Under-Floor Pedestal

Q

UIK

L

OCK

Bracket for 

12x4 System

Adjustable Ladder

Q

UIK

L

OCK

Bracket

for 12x4 System

Centre Support 

Q

UIK

L

OCK

Bracket 

for 12x4 System

Existing Threaded

Rod 

Q

UIK

L

OCK

Bracket for 

12x4 System

New Threaded Rod

Q

UIK

L

OCK

Bracket 

for 12x4 System

1

2

8

9

19

11

20

5

3

4

6

16

17

10

14

12x4 

Routing System Roadmap

12x4 

F

IBER

R

UNNER

Mounting Brackets

7

Panduit-Pannet-html.html
background image

197

Top Support

Adjustable 'C'

Q

UIK

L

OCK

Bracket 

for 12x4 System

Trapeze 

Q

UIK

L

OCK

Bracket for 

12x4 System

22

12

15

21

10

18

13

12x4 

F

IBER

R

UNNER

Channel (see page 198)

12x4 Snap-On Hinged Cover (see page 199)

12x4

Q

UIK

L

OCK

Coupler (see page 204-205)

12x4 Horizontal Right Angle Fitting and Optional 
lit Cover (see page 199)

12x4 Horizontal 45° Angle Fitting and Optional
Split Cover (see page 199)

12x4 Horizontal Tee Fitting and Optional Split
Cover (see page 199)

12x4 Four Way Cross Fitting and Optional Split
Cover (see page 200)

12x4 Four Way Cross Fitting with 6x4 Exits and
Optional Split Cover (see page 200)

3-Sided BRC Trumpet Spillout for 12x4 Exit 
(see page 200)

12x4 End Cap Fitting (see page 201)

12x4 Vertical Tee Fitting (see page 201)

3 Port Spillout to 1.5" (38mm) Inside Diameter
Corrugated Tubing (see page 201)

3-Sided BRC Trumpet Spillout for 6x4 Exit 
(see page 201)

Spill-Over Junction and Optional Cover for 
12x4 System (see page 202)

12x4 Inside Vertical 45° Angle Fitting (see page 202)

12x4 Outside Vertical 45° Angle Fitting and
Optional Split Cover (see page 202)

12x4 Outside Vertical Right Angle Fitting with
Optional Split Cover (see page 202)

Reducer from 12x4 to 6x4 

F

IBER

R

UNNER

Channel

and Optional Split Cover (see page 203)

Y-Reducer from 12x4 to two 6x4 Exits with
Optional Split Cover (see page 203)

12x4 to 6x4 Transition Right Reducer Fitting and
Optional Split Cover (see page 203)

12x4 to 6x4 Transition Left Reducer Fitting and
Optional Split Cover (see page 203)

1

2

3

4

5

6

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

12x4 Horizontal Tee with 6x4 Exits and Optional
Split Cover (see page 199)

7

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

198

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

MAX

9816

DIAMETER

1.6mm

12x4 

F

IBER

R

UNNER

Routing System Channel and Cover

• Robust, large capacity 12x4 system ideal for use with large

cable counts

• Multiple spillout options provide versatility to mate to 

various equipment and rack configurations

• QuikLock couplers and brackets reduce system installation

time dramatically

• Channel, covers, fittings and other non-metallic system

components made from V-0 flame class rated material

• UL Listed
• Compatible with all sizes of 

PANDUIT

F

IBER

R

UNNER

and 

PANDUIT F

IBRE

-D

UCT

routing systems, cable 

management products and racks

• Compliant with the applicable tests in Telcordia 

GR-63-CORE Network Equipment Building 
Systems (NEBS)

For other colour replace suffix YL (Yellow) with OR (Orange) and BL (Black)
Order number of metres required, in multiples of standard increments.
Order number of cable retainers required, in multiples of Standard Package Quantity.

FR12X4

FRHC12

FRCR12BL-X

The maximum amounts may vary according to the cable fill installation methods, straightness
of cables, etc.

SPEC= 40% cablefill — the recommended design in cable
capacity. Leaves room for future moves, adds and changes.

MAX= 60% cablefill — the maximum cable quantity
based on cable interweaving and packing factors.

System Type

F

IBER

R

UNNER

12x4 System

Area 

mm

2

32903

SPEC

4162

MAX

6243

SPEC

1865

MAX

2798

SPEC

107

MAX

161

SPEC

552

MAX

827

DIAMETER

2.0mm

DIAMETER

3.0mm

DIAMETER

12.5mm

DIAMETER

5.5mm

Fibre Cable

Data Grade

Cables

24 AWG UTP/CM

CAT5e 4 pr

112.7 mm

341.9 mm

32903 mm

2

Channel cutting instructions: 

For optimum results, use a plastic cutting saw blade for clean, burr-free cuts.

Recommend: Carbide 80T or 100T; 2.29mm thickness, 3.2mm kerf.

Cable Fills for 

F

IBER

R

UNNER

12x4 Cable Routing System

12x4 

F

IBER

R

UNNER

Routing System

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

12x4 

F

IBER

R

UNNER

Channel

FR12X4YL6

Used to carry the cables horizontally throughout the system. Accepts
cable retainers FRCR12BL-X or hinged cover FRHC12YL6. Use
QuikLock coupler FRBC12X4YL to attach channel and/or fittings.

6

12

12x4 Snap-On Hinged Cover

FRHC12YL6

Optional snap-on hinged cover for channel FR12X4YL6. Can be folded
down for height restricted areas.

6

12

Cable Retainer for 12x4 System

FRCR12BL-X Cable retainer holds cable in the channel when cover is not used. 

Install anywhere on channel, near the coupler or every 457mm. 
Black colour only.

10

100

SPEC

6544

FR12X4

Panduit-Pannet-html.html
background image

199

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

FRRA12X4

FRRASC12

FRH4512X4

FRH45SC12

FRT12X4

FRBC12X4

12x4 

F

IBER

R

UNNER

Q

UIK

L

OCK

Coupler

• Pre-assembled to provide fast mechanical assembly 

of components

• No tools required for installation, bolts loosen for 

component disassembly

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

12x4 

F

IBER

R

UNNER

System Fittings

• Minimum 50mm bend radius control fittings
• Protects against signal loss and performance degradation
• Fittings assemble using FRBC couplers

• Optional split covers snap onto each fitting
• Covers feature 19mm gap to allow cable to be laid in

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

12x4 QuikLock Coupler

FRBC12X4YL

Pre-assembled coupler quickly joins 2 sections of channel and/or
fittings. Mechanically attaches without tightening bolts. Bolts release
using 3/8 nut driver to allow coupler to be removed if necessary.

1

5

Part Number

Part Description

Couplers
Required

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

12x4 Horizontal Right Angle Fitting

FRRA12X4YL

Attaches to 12x4 channel and/or fitting to create a 90°
horizontal turn from a straight horizontal run. Accepts
optional split cover FRRASC12YL.

(2 pcs.)

FRBC12X4YL

1

0

Split Cover for 12x4 Horizontal Right Angle Fitting

FRRASC12YL

Optional split cover for the horizontal right angle fitting
FRRA12X4YL. Snap-on feature allows cover to be
installed and removed with no tools required. Creates
radiused 19mm opening for easy access to add or
remove cables.

1

5

12x4 Horizontal 45° Angle Fitting

FRH4512X4YL

Attaches to 12x4 channel and/or fitting to create a 45°
horizontal turn from a straight horizontal run. Accepts
optional split cover FRH45SC12YL

(2 pcs.)

FRBC12X4YL

1

0

Split Cover for 12x4 Horizontal 45° Angle Fitting

FRH45SC12YL

Optional split cover for the horizontal 45° angle fitting
FRH4512X4YL. Snap-on feature allows cover to be
installed and removed with no tools required. Creates
radiused 19mm opening for easy access to add or
removes cables.

1

5

12x4 Horizontal Tee Fitting

FRT12X4YL

Attaches to 12x4 channel and/or fittings to create a 90°
horizontal branch with a 12x4 exit from straight
horizontal run. Accepts optional split cover FRTSC12YL.

(3 pcs.)

FRBC12X4YL

1

0

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

200

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For other colour replace suffix YL (Yellow) with OR (Orange).

FRFWCSC12

FRFWC12X4W6

FRFWCSC12W6

FRTR12X4

12x4 

F

IBER

R

UNNER

System Fittings (continued)

FRT12X4W6

FRTSC12W6

FRFWC12X4

FRTSC12

Part Number

Part Description

Couplers
Required

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Split Cover for 12x4 Horizontal Tee Fitting

FRTSC12YL

Optional split cover for the horizontal tee fitting
FRT12X4YL. Snap-on feature allows cover to be
installed and removed with no tools required. Creates
radiused 19mm opening for easy access to add or
remove cables.

1

5

12x4 Horizontal Tee with 6x4 Exit

FRT12X4W6YL

Attaches to 12x4 channel and/or fittings to create a 90°
horizontal branch with a 6x4 exit from straight
horizontal run. Accepts optional split cover
FRTSC12W6YL.

(2 pcs.)

FRBC12X4YL

(1 pc.)

FRBC6X4YL

1

Split Cover for 12x4 Horizontal Tee with 6x4 Exit

FRTSC12W6YL

Optional split cover for the horizontal tee with 6x4 exit
fitting FRT12X4W6YL. Snap-on feature allows cover to
be installed and removed with no tools required.
Creates radiused 19mm opening for easy access to
add or remove fibre cables.

1

5

12x4 Four Way Cross Fitting

FRFWC12X4YL

Attaches to 12x4 channel and/or fittings to create a
horizontal four way cross intersection with two 12x4
exits. Accepts optional split cover FRFWCSC12YL.

(4 pcs.)

FRBC12X4YL

1

Split Cover for 12x4 Four Way Cross Fitting

FRFWCSC12YL

Optional split cover for the four way cross fitting
FRFWC12X4YL. Snap-on feature allows cover to be
installed and removed with no tools required. Creates
radiused (19mm) opening for easy access to add or
remove cables.

1

5

12x4 Four Way Cross Fitting with 6x4 Exits

FRFWC12X4W6YL

Attaches to 12x4 channel and/or fittings to create a
horizontal four way cross intersection with two 6x4
exits. Accepts optional split cover FRFWCSC12W6YL.

(2 pcs.)

FRBC12X4YL

(2 pcs.)

FRBC6X4YL

1

Split Cover for 12x4 Four Way Cross Fitting with 6x4 Exits

FRFWCSC12W6YL

Optional split cover for the four way cross fitting
FRFWC12X4W6YL. Snap-on feature allows cover to
be installed and removed with no tools required.
Creates radiused (19mm) opening for easy access to
add or remove cables.

1

5

3-Sided BRC Trumpet Spillout for 12x4 Exit

FRTR12X4YL

Used to limit the bend of the fibre cable to 50.4mm
when exiting from the 12x4 channel or a 12x4
horizontal tee fitting.

(1 pc.)

FRBC12X4YL

1

5

Panduit-Pannet-html.html
background image

201

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

FREC12X4

FRVT12X4

FR1.5IDE

FRIDT6X4

FRTR6X4

FRSP

FRSP12C

FRSP4

12x4 

F

IBER

R

UNNER

System Fittings (continued)

Part Number

Part Description

Couplers
Required

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

12x4 End Cap Fitting

FREC12X4YL

Used for closing off open ends of the channel or fittings.
No coupler required, push-on installation.

1

5

12x4 Vertical Tee Fitting

FRVT12X4YL

Attaches to 12x4 channel and/or fittings to create a 90°
vertical drop from a horizontal run. Hinged door
included. Requires coupler to attach FRIDT6X4YL or
FRTR6X4YL to vertical exit. Accepts optional snap-on
cover FRHC12YL6 in conjunction with channel.

(2 pcs.)

FRBC12X4YL

(1 pc.)

FRBC6X4YL

1

0

1 Port Spillout Side Exit to 38mm Inside Diameter Corrugated Tubing

FR1.5IDEYL

Used to route cable into 38mm diameter split corrugated
tubing directly through a hole cut in the side wall of the
4x4, 6x4 and 12x4 

F

IBER

R

UNNER

channel or 4x4 

F

IBER

-D

UCT

channel. Provides 25.4mm bend radius

control at the exit. Securely holds split corrugated tubing
to ensure system integrity and easy access to add or
remove cables. Includes drilling template.

1

5

3 Port Spillout to 38mm Inside Diameter Corrugated Tubing

FRIDT6X4YL

Used to route cable into 3 separate pieces of 38mm
diameter split corrugated tubing. Used with
FRVT12X4YL or any 6x4 fitting. Securely holds
corrugated split tubing to ensure system integrity and
easy access to add or remove cables.

(1 pc.)

FRBC6X4YL

1

5

3-Sided BRC Trumpet Spillout for 6x4 Exit

FRTR6X4YL

Used to limit the bend of the fibre cable to 50.8mm when
exiting from 6x4 channel, 6x4 horizontal tee fitting, or
6x4 exit or 12x4 vertical tee.

(1 pc.)

FRBC6X4YL

1

5

Spill-Over Junction with 2x2 Exit

FRSPYL

Assembles onto 4x4, 6x4 or 12x4 

F

IBER

R

UNNER

channel spilling over the side into a 2x2 vertical channel,
fitting or corrugated tube. Mounts directly to existing
installation with no alteration required. Mounting
hardware provided for secure attachment.

1

0

Spill-Over Junction Cover for 12x4 System

FRSP12CYL

Used to fully enclose 12x4 channel in conjunction with
the spill-over junction FRSPYL. Cover snaps onto the
channel base. Hinged feature allows easy access to add
or remove cables.

1

5

Spill-Over Junction with 4x4 Exit

FRSP4YL

Assembles onto 4x4, 6x4, or 12x4 

F

IBER

R

UNNER

channel spilling over the side into a 4x4 vertical exit.
Requires coupler to attach 4x4 

F

IBER

R

UNNER

channel

and fittings to vertical exit. Mounts directly to existing
installation with no alteration required. Mounting
hardware provided for secure attachment.

(1) FRBC4X4YL

1

0

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

202

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

FROVRA12X4

FROVRASC12

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

12x4 

F

IBER

R

UNNER

System Fittings (continued)

FTR2X2

FIDT2X2

FRIV4512X4

FROV4512X4

FROV45SC12

FRSP412C

Part Number

Part Description

Couplers
Required

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Spill-Over Junction Cover for 12x4 System

FRSP412CYL

Used to fully enclose 12x4 channel in conjunction with
the spill-over junction FRSP4YL. Cover snaps onto the
channel base. Hinged feature allows easy access to add
or remove cables.

1

5

3-Sided BRC Trumpet Spillout for 2x2 Exit

FTR2X2YL

Used to limit the bend of the fibre cable to 50mm when
exiting from a 

F

IBER

R

UNNER

spill-over fitting FRSPYL

or from 2x2 

F

IBER

-D

UCT

channel.

1

5

1-Port Spillout to 38mm Inside Diameter Corrugated Tubing

FIDT2X2YL

Used to route cable into one piece of 38.1mm diameter
split corrugated tubing. Used with 

F

IBER

R

UNNER

spill-over fitting FRSPYL, 2x2 

F

IBER

-D

UCT

fittings and

the 2x2 

F

IBER

R

UNNER

hinged channel. Securely holds

split corrugated tubing to ensure system integrity and
easy access to add or remove cables.

1

5

12x4 Inside Vertical 45° Angle Fitting

FRIV4512X4YL

Attaches to 12x4 channel and/or fitting to create a 45°
upward angle from a straight horizontal run. Used with
outside vertical 45° angle fitting FROV4512X4YL to
change level of a straight horizontal run. Includes split
cover.

(2 pcs.)

FRBC12X4YL

1

12x4 Outside Vertical 45° Angle Fitting

FROV4512X4YL

Attaches to 12x4 channel and/or fitting to create a 45°
downward angle from a straight horizontal run. Used
with inside vertical 45° angle fitting FRIV4512X4YL to
change level of a horizontal run. Accepts optional split
cover FROV45SC12YL.

(2 pcs.)

FRBC12X4YL

1

Split Cover for 12x4 Outside Vertical 45° Angle Fitting

FROV45SC12YL

Optional split cover for the outside vertical 45° angle
fitting FROV4512X4YL. Snap-on feature allows cover to
be installed and removed with no tools required. Creates
radiused 19mm opening for easy access to add or
remove cables.

1

5

12x4 Outside Vertical Right Angle Fitting

FROVRA12X4YL

Attaches to 12x4 channel and/or fittings to create a 90°
vertical turn down from a straight horizontal run. Accepts
optional split cover FROVRASC12YL.

(2 pcs.)

FRBC12X4YL

1

Split Cover for 12x4 Outside Vertical Right Angle Fitting

FROVRASC12YL

Optional split cover for the outside vertical right angle
fitting FROVRA12X4YL. Snap-on feature allows cover to
be installed and removed with no tools required. Creates
radiused 19mm opening for easy access to add or
remove cables.

1

5

RFRIV4512.eps

Panduit-Pannet-html.html
background image

203

FRRF126

FRRF126SC

FRY126

FRY126SC

FRRF126R

FRRF126RSC

FRRF126L

FRRF126LSC

12x4 

F

IBER

R

UNNER

System Fittings (continued)

For other colour replace YL (Yellow) with OR (Orange) or BL (Black)

Part Number

Part Description

Couplers
Required

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

12x4 to 6x4 

F

IBER

R

UNNER

Reducer Fitting

FRRF126YL

Attaches any 12x4 

F

IBER

R

UNNER

fitting or channel to

any 6x4 

F

IBER

R

UNNER

fitting or channel. Accepts split

cover FRRF126SCYL.

(1 pc.)

FRBC12X4YL

(1 pc.)

FRBC6X4YL

1

0

Split Cover for 12x4 to 6x4 

F

IBER

R

UNNER

Reducer Fitting

FRRF126SCYL

Optional split cover for the reducer fitting FRRF126YL.
Snap-on feature allows cover to be installed and
removed with no tools required. Creates radiused 19mm
opening for easy access to add or remove cables.

1

5

Y-Reducer from 12x4 to two 6x4 Exits

FRY126YL

Attaches any 12x4 

F

IBER

R

UNNER

fitting or channel to

two 6x4 

F

IBER

R

UNNER

channels. Accepts split cover

FRY126SCYL.

(1 pc.)

FRBC12X4YL

(2 pcs.)

FRBC6X4YL

1

0

Split Cover for Y-Reducer from 12x4 to two 6x4 Exits

FRY126SCYL

Optional split cover for the Y-reducer fitting FRY126YL.
Snap-on feature allows cover to be installed and
removed with no tools required. Creates radiused 19mm
opening for easy access to add or remove fibre cables.

1

5

12x4 to 6x4 Transition Right Reducer Fitting

FRRF126RYL

Attaches any 12x4 

F

IBER

R

UNNER

fitting or channel to

any 6x4 

F

IBER

R

UNNER

fitting or channel while

transitioning to the right. Accepts split cover
FRRF126RSCYL.

(1 pc.)

FRBC12X4YL

(1 pc.)

FRBC6X4YL

1

0

Split Cover for 12x4 to 6x4 Transition Right Reducer Fitting

FRRF126RSCYL

Optional split cover for the transition right reducer fitting
FRRF126RYL. Snap-on feature allows cover to be
installed and removed with no tools required. Creates
radiused 19mm opening for easy access to add or
remove fibre cables.

1

5

12x4 to 6x4 Transition Left Reducer Fitting

FRRF126LYL

Attaches any 12x4 

F

IBER

R

UNNER

fitting or channel to

any 6x4 

F

IBER

R

UNNER

fitting or channel while

transitioning to the left. Accepts split cover
FRRF126LSCYL.

(1 pc.)

FRBC12X5YL

(1 pc.)

FRBC6X4YL

1

0

Split Cover for 12x4 to 6x4 Transition Left Reducer Fitting

FRRF126LSCYL

Optional split cover for the transition left reducer fitting
FRRF126LYL. Snap-on feature allows cover to be
installed and removed with no tools required. Creates
radiused 19mm opening for easy access to add or
remove cables.

1

5

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

204

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

FR12TRBE58

FR12TRBE58M

FR12TRBN58

FR12TRBN58M

FR12USB

FR12ACB12
FR12ACB58

FR12ACB12M
FR12ACB58M

FR12CS12
FR12CS58

FR12CS12M
FR12CS58M

FR12ALB

FR12TB12
FR12TB58

FR12TB12M
FR12TB58M

12x4 

F

IBER

R

UNNER

Mounting Brackets

Part Number

Part Description

For

Threaded

Rod Size

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Existing Threaded Rod 

Q

UIK

L

OCK

Bracket for 12x4 System

FR12TRBE58

Used to support the 12x4 system from existing
threaded rod installations. Bracket is secured to
threaded rod with two split nuts. The pre-assembled
slide clamps enable fast assembly to channel. Use
11.1mm nut driver on slide clamps.

5/8"

1

0

FR12TRBE58M

16 mm

1

0

New Threaded Rod 

Q

UIK

L

OCK

Bracket for 12x4 System

FR12TRBN58

Used to support the 12x4 system from new threaded
rod installations. Bracket is secured to threaded rod
with two split nuts. The pre-assembled slide clamps
enable fast assembly to channel. Use 7/16” = 11.1mm
nut driver on slide clamps.

5/8"

1

0

FR12TRBN58M

16 mm

1

0

Under-Floor Pedestal 

Q

UIK

L

OCK

Bracket for 12x4 System

FR12USB

1

0

Adjustable Ladder 

Q

UIK

L

OCK

Bracket for 12x4 System

FR12ALB

Used to support the 12x4 system attaching to any
9.5mm x 38.1mm or 9.5mm x 50.8mm ladder rack rail.
Adjustable to 9 incremental positions from 101mm to
304mm above or below the ladder rack. No threaded
rod required. The pre-assembled slide clamps enable
fast assembly to channel. Use 11.1mm nut driver on
slide clamps.

1

0

centre Support 

Q

UIK

L

OCK

Bracket for 12x4 System

FR12CS12

Used to support the 12x4 system from below with new
threaded rod. Bracket is secured to threaded rod with
two nuts. The pre-assembled slide clamps enable fast
assembly to channel. Use 11.1mm nut driver on slide
clamps. Also can be secured directly to the top 
of cabinets.

1/2"

1

0

FR12CS58

1/8"

1

0

FR12CS12M

12 mm

1

0

FR12CS58M

16 mm

1

0

Top Support Adjustable "C"

Q

UIK

L

OCK

Bracket for 12x4 System

FR12ACB12

Used to support the 12x4 system from any new
threaded rod extending down directly from the ceiling,
grid or ladder rack system. Two position height
adjustments to accommodate system with or without
hinged cover. Bracket is secured to threaded rod with
two nuts. The pre-assembled slide clamps enable fast
assembly to channel. Use 11.1mm nut driver on 
slide clamps.

1/2"

1

0

FR12ACB58

5/8"

1

0

FR12ACB12M

12 mm

1

0

FR12ACB58M

16 mm

1

0

Trapeze 

Q

UIK

L

OCK

Bracket for 12x4 System

FR12TB12

Used to support the 12x4 system by spanning two
threaded rod drops. Can be installed from above or
below. Bracket is secured to each threaded rod with
two nuts. The pre-assembled slide clamps enable fast
assembly to channel. Use 11.1mm nut driver on 
slide clamps. 

1/2"

1

0

FR12TB58

5/8"

1

0

FR12TB12M

12 mm

1

0

FR12TB58M

16 mm

1

0

Used to support the 12x4 system by attaching to 
under-floor pedestals. (Contains all necessary hardware.)
Use on pedestals up to 50.8mm diameter. 
The pre-assembled slide clamps enable fast assembly to
channel. Use 11.1mm nut driver on slide clamps.

Panduit-Pannet-html.html
background image

205

F2PCLB12
F2PCLB58

F2PCLB12M
F2PCLB58M

FR12BS-L

FLB12X15
FLB58X15
FLB12X20
FLB58X20

FRSTRCLIP

FRSLNKT12
FRSLNKT58

FRSLNKT12M
FRSLNKT58M

FRTBKT-X

FEIAB58

12x4 

F

IBER

R

UNNER

Mounting Brackets (continued)

Part Number

Part Description

For

Threaded

Rod Size

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

EIA/TIA Threaded Rod Mounting Bracket

FEIAB58

Bracket consists of two identical components that clamp onto the
crossmembers of standard EIA/TIA racks and are secured with
standard hex nuts and split lockwashers (included) tightened
onto a length of 5/8 diameter threaded rod (not included). The
threaded rod is positioned in the centre of the brackets providing
a vertical threaded rod stud to mount 

F

IBER

R

UNNER

and 

F

IBER

-D

UCT

threaded rod mounting brackets onto.

5/8"

1

10

Two Piece Ladder Rack Bracket for Attaching Threaded Rod 
to 38.1mm - 50.8mm Ladder Rack

F2PCLB12

Two piece bracket attaches to 9.5mm wide x 38.1mm or 9.5mm
wide by 50.8mm ladder rack rail. Bracket halves slide into
position and clamp together on the ladder rack rail, which allows
for a one-handed assembly of the threaded rod (not included).
Contains bracket and hardware for attaching bracket to 
ladder rack.

1/2"

1

10

F2PCLB58

5/8"

1

10

F2PCLB12M

12 mm

1

10

F2PCLB58M

16 mm

1

10

Self Tapping Screws for 12x4 Brackets

FR12BS-L

Self tapping screws allow selected 12x4 fittings to be fastened
directly to mounting brackets for additional support. Screws tap
directly into those 12x4 fittings that have plastic bosses. Those
part numbers are FRRA12X4YL, FRH4512X4YL, FRT12X4YL,
FRT12X4W6YL, FRFWC12X4YL, FRFWC12X4W6YL,
FRVT12X4YL, FRRF126RYL and FRF126LYL.

50

500

Bracket for Attaching Threaded Rod to 38.1mm Ladder Rack

FLB12X15

Bracket attaches to 9.5mm x 38.1mm ladder rack rail. Bracket
accepts threaded rod (not included). Contains bracket and
hardware for attaching bracket to ladder rack.

1/2"

1

10

FLB58X15

5/8"

1

10

Bracket for Attaching Threaded Rod to 50.8mm Ladder Rack

FLB12X20

Bracket attaches to 9.5mm wide x 50.8mm ladder rack rail.
Bracket accepts threaded rod (not included). Contains bracket
and hardware for attaching bracket to ladder rack.

1/2"

1

10

FLB58X20

5/8"

1

10

Strut Clip Kit

FRSTRCLIP

Strut mounting clip assembly allows 

F

IBER

R

UNNER

channel to

be attached directly to standard 41.3mm wide strut structures.
Contains all hardware for assembly. Bolts release with 11.1mm
nut driver.

1

10

Split Locking Nut Kit

FRSLNKT12

Used to secure 

F

IBER

R

UNNER

mounting brackets anywhere

along pre-installed threaded rod. Split nuts are opened, placed in
desired position, closed and tightened.

1/2"

1

10

FRSLNKT58

5/8"

1

10

FRSLNKT12M

12 mm

1

10

FRSLNKT58M

16 mm

1

10

1/4 T-Bolt Kit

FRTBKT-X

T-bolts can be used for additional attachment when securing

F

IBER

R

UNNER

channel to mounting brackets. For example, a 

T-bolt can be inserted through a 12x4 mounting bracket and
positioned within the centre rib structure on the underside of
12x4 channel. By tightening the nut, the 12x4 channel is more
securely fastened to the mounting bracket.

10

100

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

206

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

New Threaded Rod

Q

UIK

L

OCK

Bracket for

6x4 and 4x4 Systems

Under-Floor Pedestal

Q

UIK

L

OCK

Bracket for

6x4 and 4x4 Systems

Adjustable Ladder

Q

UIK

L

OCK

Bracket for

6x4 and 4x4 Systems

Existing Threaded Rod

Q

UIK

L

OCK

Bracket for

6x4 and 4x4 Systems

17

16

8

20

4

1

3

6

5

2

19

12

10

7

18

6x4                       Routing System Roadmap

4x4 and 6x4 

F

IBER

R

UNNER

Mounting Brackets

Panduit-Pannet-html.html
background image

207

Top Support

Adjustable 'C'

Q

UIK

L

OCK

Bracket

for 6x4 and

4x4 Systems

Centre Support

Q

UIK

L

OCK

Bracket for

6x4 and 4x4 Systems

14

13

11

15

9

6x4 

F

IBER

R

UNNER

Channel (see page 208)

6x4 Snap-On Hinged Cover (see page 208)

6x4 Split Hinged Cover (see page 208)

6x4 

Q

UIK

L

OCK

Coupler (see page 209)

6x4 Horizontal Right Angle Fitting and Optional
Split Cover (see page 209)

6x4 Horizontal 45° Angle Fitting and Optional
Split Cover (see page 209)

6x4 Horizontal Tee Fitting and Optional
Split Cover (see page 209)

6x4 Four Way Cross Fitting and Optional Split Cover
(see page 210)

3-Sided BRC Trumpet Spillout for 6x4 Exit 
(see page 210)

6x4 End Cap Fitting (see page 210)

6x4 

Q

UIK

L

OCK

™ 

Vertical Tee Fitting (see page 210)

3-Sided Vertical Tee Trumpet Spillout (see page 210)

Low Profile Reducer 4x4 to 2x2 for Vertical Tee 
(see page 210)

Spill-Over Junction and Optional Cover for 
6x4 System (see page 211)

3-Sided BRC Trumpet Spillout for 2x2 Exit 
(see page 211)

6x4 Inside Vertical 45° Angle Fitting (see page 211)

6x4 Outside Vertical 45° Angle Fitting and
Optional Split Cover (see page 211)

6x4 to 4x4 

F

IBER

R

UNNER

Reducer Fitting and

Optional Split Cover (see page 212)

6x4 

F

IBER

R

UNNER

Fitting to 4x4 

F

IBER

-D

UCT

Channel Reducer Fitting (see page 212)

NOTE: Additional 6x4 and 4x4 bracket applications, see pages 142-143

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

19

20

6x4 Outside Vertical Right Angle Fitting and
Optional Split Cover (see page 212)

18

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

208

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

6x4 

F

IBER

R

UNNER

Routing System Channel and Covers

• Robust, large capacity 6x4 system ideal for use with large

cable counts

• Multiple spillout options provide versatility to mate to 

various equipment and rack configurations

Q

UIK

L

OCK

couplers and brackets reduce system 

installation time dramatically

• Channel, covers, fittings and other non-metallic system

components made from V-0 flame class rated material

• UL Listed
• Compatible with all sizes of 

PANDUIT

F

IBER

R

UNNER

and 

PANDUIT

Fibre-Duct routing systems, cable 

management products and racks

• Compliant with the applicable tests in Telcordia 

GR-63-CORE Network Equipment Building 
Systems (NEBS)

For other colour replace YL (Yellow) with OR (Orange) or BL (Black)
Order length required, in standard length increments.
Order number of cable retainers required, in multiples of Standard Package Quantity.

FR6X4

FRHC6

FRCR6BL-X

FRSHC6

112.7mm

167.3mm

A=15354mm

2

Channel cutting instructions: For optimum results, use FRCUT Miter box and saw. For larger quantities
use a plastic cutting saw blade for clean, burr-free cuts. Recommend: Carbide 80T or 100T; 2.29mm
thickness, 3.2 mm.

The maximum amounts may vary according to the cable fill installation methods, 
straightness of cables, etc.

SPEC= 40% cablefill — the recommended design in cable
capacity. Leaves room for future moves, adds and changes.

Cable Fills for 

F

IBER

R

UNNER

6x4 Cable Routing System

6x4 

F

IBER

R

UNNER

Routing System

SPEC

3054

MAX

4581

DIAMETER

1.6mm

System Type

F

IBER

R

UNNER

6x4 System

Area 

mm

2

15354

SPEC

1942

MAX

2913

SPEC

871

MAX

1306

SPEC

50

MAX

75

SPEC

257

MAX

386

DIAMETER

2.0mm

DIAMETER

3.0mm

DIAMETER

12.5mm

DIAMETER

5.5mm

Fibre Cable

Data Grade

Cables

24 AWG UTP/CM

CAT5e 4 pr

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

6x4 FiberRunner Channel

FR6X4YL6

Used to carry the cables horizontally throughout the system. Accepts
hinged cable retainers FRCR6BL-X, hinged cover FRHC6YL6 or split
hinged cover FRSHC6YL6. Use QuikLock coupler FRBC6X4YL to
attach channel and/or fittings.

6

36

6x4 Snap-On Hinged Cover

FRHC6YL6

Optional snap-on hinged cover for channel FR6X4YL6. Hinge feature
enables positioning of cover at angles between 30° and 90°.

6

36

6x4 Split Hinged Cover

FRSHC6YL6

Optional split hinged cover for the channel FR6X4YL6. Creates
radiused 19mm opening for easy access to add or remove cables.
Snap-on hinge feature enables positioning of cover at angles between
30° and 90°.

6

36

Cable Retainer for 6x4 System

FRCR6BL-X

Cable retainer holds cable in the channel when cover is not used.
Install anywhere on channel, near the coupler or every 457mm. 
Black colour only.

10

100

Panduit-Pannet-html.html
background image

209

6x4 

F

IBER

R

UNNER

Q

UIK

L

OCK

Coupler

• Pre-assembled to provide fast mechanical assembly 

of components

• No tools required for installation, bolts loosen for 

component disassembly

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

FRBC6X4

FRRA6X4

FRRASC6

FRH456X4

FRH45SC6

FRT6X4

FRTSC6

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

6x4 

F

IBER

R

UNNER

System Fittings

• Minimum 50.8mm bend radius control fittings
• Protects against signal loss and performance degradation
• Fittings assemble using FRBC couplers

• Optional split covers snap onto each fitting
• Covers feature 19mm gap to allow cable to be laid in

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FRBC6X4YL

Pre-assembled coupler quickly joins 2 sections of channel and/or
fittings. Mechanically attaches without tightening bolts. Bolts release
using 9.5mm nut driver to allow coupler to be removed if necessary.

1

5

Part Number

Part Description

Couplers 
Required

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

6x4 Horizontal Right Angle Fitting

FRRA6X4YL

Attaches to 6x4 channel base and/or fittings to create a 90°
horizontal turn from a straight horizontal run. Accepts
optional split cover FRRASC6YL.

(2 pcs.)

FRBC6X4YL

1

5

Split Cover for 6x4 Horizontal Right Angle Fitting

FRRASC6YL

Optional split cover for the horizontal right angle fitting
FRRA6X4YL. Snap-on feature allows cover to be installed
and removed with no tools required. Creates radiused 19mm
opening for easy access to add or remove cables.

1

5

6x4 Horizontal 45° Angle Fitting

FRH456X4YL

Attaches to 6x4 channel and/or fittings to create a 45°
horizontral turn from a straight horizontal run. Accepts
optional split cover FRH45SC6YL.

(2 pcs.)

FRBC6X4YL

1

5

Split Cover for 6x4 Horizontal 45° Angle Fitting

FRH45SC6YL

Optional split cover for the horizontal 45° angle fitting
FRH456X4YL. Snap-on feature allows cover to be installed
and removed with no tools required. Creates radiused 19mm
opening for easy access to add or remove cables.

1

5

6x4 Horizontal Tee Fitting

FRT6X4YL

Attaches to 6x4 channel and/or fittings to create a 90°
horizontal branch from straight horizontal runs. Accepts
optional split cover FRTSC6YL.

(3 pcs.)

FRBC6X4YL

1

5

Split Cover for 6x4 Horizontal Tee Fitting

FRTSC6YL

Optional split cover for the horizontal tee fitting FRT6X4YL.
Snap-on feature allows cover to be installed and removed
with no tools required. Creates radiused 19mm opening for
easy access to add or remove cables.

1

5

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

210

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

FRFWC6X4

FRFWCSC6

FRTR6X4

FREC6X4

FRVT6X4

FR1.5IDE

FIDT4X4BL

FTR4X4

FRLPR42BL

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

6x4 

F

IBER

R

UNNER

System Fittings (continued)

Part Number

Part Description

Couplers 
Required

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

6x4 Four Way Cross Fitting

FRFWC6X4YL

Attaches to 6x4 channel and/or fittings to create a horizontal
four way cross intersection. 
Accepts optional split cover FRFWCSC6YL.

(4 pcs.)

FRBC6X4YL

1

5

Split Cover for 6x4 Four Way Cross Fitting

FRFWCSC6YL

Optional split cover for the four way cross fitting
FRFWC6X4YL. Snap-on feature allows cover to be installed
and removed with no tools required. Creates radiused 19mm
opening for easy access to add or remove cables.

1

5

3-Sided BRC Trumpet Spillout for 6x4 Exit

FRTR6X4YL

Used to limit the bend of the fibre cable to 50.8mm when
exiting from 6x4 channel, 6x4 horizontal tee fitting, or 6x4
exit or 12x4 vertical tee.

(1 pc.)

FRBC6X4YL

1

5

6x4 End Cap Fitting

FREC6X4YL

Used for closing off open ends of the channel or fittings. No
coupler required, push-on installation.

1

5

6x4 QuikLock Vertical Tee Fitting

FRVT6X4YL

Attaches to 6x4 channel and/or fittings to create a 90°
vertical drop from a straight horizontal run. Hinged door
included. Accepts FIDT4X4BL, FTR4X4YL, S4X4YL6,
E4X4YL6 directly. Accepts optional snap-on cover
FRHC6YL6 in conjunction with channel.

(2 pcs.)

FRBC6X4YL

1

5

1 Port Spillout Side Exit to 38mm Inside Diameter Corrugated Tubing

FR1.5IDEYL

Used to route cable into 38mm diameter split corrugated
tubing directly through a hole cut in the side wall of the 4x4,
6x4 and 12x4 

F

IBER

R

UNNER

channel or 4x4 

F

IBER

-D

UCT

channel. Provides 25.4mm bend radius control at the exit.
Securely holds split corrugated tubing to ensure system
integrity and easy access to add or remove cables. Includes
drilling template.

1

5

2-Port Spillout to 38mm Inside Diameter Corrugated Tubing

FIDT4X4BL

Used to route cable into one or two pieces of 38mm
diameter split corrugated tubing. Used with FRVT6X4YL,
FRVT4X4YL or FVT4X4YL. Securely holds corrugated split
tubing to ensure system integrity and easy access to add or
remove cables. Black colour only.

1

5

3-Sided Vertical Tee Trumpet Spillout

FTR4X4YL

Used to limit the bend raidus of the cable to 50.8mm when
exiting from a 4x4 or 6x4 

F

IBER

R

UNNER

vertical tee fitting

and 4x4 

F

IBER

-D

UCT

fittings.

1

5

Low Profile Reducer 4x4 to 2x2 for Vertical Tee

FRLPR42BL

Assembled into the 6x4 vertical tee FRVT6X4YL or 4x4
vertical tee FRVT4X4YL with an audible snap, the
FRLPR42BL allows for the transition to 2x2 

F

IBER

-D

UCT

channel with minimal space required. No tools required for
assembly. Black colour only.

1

5

Panduit-Pannet-html.html
background image

211

FRDDS6X4

FRDDSHC6

FRSP

FRSP6C

FRSP4

FRSP46C

FTR2X2

FIDT2X2

FRIV456X4

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

6x4 

F

IBER

R

UNNER

System Fittings (continued)

Part Number

Part Description

Couplers 
Required

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

6x4 Dual Downspout Fitting

FRDDS6X4YL

Attaches to 6x4 channel and/or fittings to create two 90 4x4
downward transitions from a horizontal run. Downspouts are
positioned 600mm apart to provide drops into cable
entrances on multiple cabinet line-ups. The fitting maintains a
50.8mm bend radius control throughout the transition to the
vertical downspouts. Includes two snap-on throat covers for
the dual downspouts. Accepts optional cover FRDDSHC6YL.

(2)

FRBC6X4YL

(2)

FRBC4X4YL

1

Cover for 6x4 Dual Downspout Fitting

FRDDSHC6YL

Used to fully enclose the 6x4 dual downspout fitting
FRDDS6X4YL. Cover is attached to the fitting base with
three hinge clips. The hinge clips allow the hinged cover to
rotate to a fully closed position and an open position greater
than 90.

1

5

Spill-Over Junction with 2x2 Exit

FRSPYL

Assembles onto 4x4, 6x4 or 12x4 

F

IBER

R

UNNER

channel

spilling over the side into a 2x2 vertical channel, fitting or
corrugated tube. Mounts directly to existing installation with
no alteration required. Mounting hardware provided for
secure attachment.

1

Spill-Over Junction Cover for 6x4 System

FRSP6CYL

Used to fully enclose 6x4 channel in conjunction with the
spill-over junction FRSPYL. Cover snaps on to the channel
base. Hinged feature allows easy access to add or remove
cables.

1

5

Spill-Over Junction with 4x4 Exit

FRSP4YL

Assembles onto 4x4, 6x4, or 12x4 

F

IBER

R

UNNER

channel

spilling over the side into a 4x4 vertical exit. Requires
coupler to attach 4x4 

F

IBER

R

UNNER

channel and fittings to

vertical exit. Mounts directly to existing installation with 
no alteration required. Mounting hardware provided for
secure attachment.

(1)

FRBC4X4YL

1

Spill-Over Junction Cover for 6x4 System

FRSP46CYL

Used to fully enclose the 6x4 channel in conjunction with the
spill-over junction FRSP4YL. Cover snaps onto the channel
base. Hinged feature allows easy access to add or remove
cables.

1

5

3-Sided BRC Trumpet Spillout for 2x2 Exit

FTR2X2YL

Used to limit the bend of the fibre cable to 50mm when
exiting from a 

F

IBER

R

UNNER

spill-over fitting FRSPYL or

from 2x2 

F

IBER

-D

UCT

channel.

1

5

1-Port Spillout to 38mm Inside Diameter Corrugated Tubing

FIDT2X2YL

Used to route cable into one piece of 38.1mm diameter split
corrugated tubing. Used with 

F

IBER

R

UNNER

spill-over fitting

FRSPYL, 2x2 Fibre-Duct fittings and the 2x2 

F

IBER

R

UNNER

hinged channel. Securely holds split corrugated tubing to
ensure system integrity and easy access to add or 
remove cables.

1

5

6x4 Inside Vertical 45° Angle Fitting

FRIV456X4YL

Attaches to 6x4 channel and/or fitting to create a 45° upward
angle from a straight horizontal run. Used with outside
vertical 45° angle fitting FROV456X4YL to change level of a
straight horizontal run. Includes split cover.

(2 pcs.)

FRBC6X4YL

1

5

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

212

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

FROV456X4

FROV45SC6

FROVRA6X4

FROVRASC6

FRUPS6X4

FRRF6FR4

FRRF6FR4SC

FRRF64

FITF6X4

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

6x4 

F

IBER

R

UNNER

System Fittings (continued)

Part Number

Part Description

Couplers 
Required

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

6x4 Outside Vertical 45° Angle Fitting

FROV456X4YL

Attaches to 6x4 channel and/or fitting to create a 45°
downward angle from a straight horizontal run. Used with
inside vertical 45° angle fitting FRIV456X4YL to change level
of a straight horizontal run. Accepts optional split cover
FROV45SC6YL.

(2 pcs.)

FRBC6X4YL

1

5

Split Cover for 6x4 Outside Vertical 45° Angle Fitting

FROV45SC6YL

Optional split cover for the outside vertical 45° angle fitting
FROV456X4YL. Snap-on feature allows cover to be installed
and removed with no tools required. Creates radiused 19mm
opening for easy access to add or remove cables.

1

5

6x4 Outside Vertical Right Angle Fitting

FROVRA6X4YL

Attaches to 6x4 channel and/or fittings to create a 90°
vertical turn from a straight horizontal run. Accepts optional
split cover FROVRASC6YL.

(2 pcs.)

FRBC6X4YL

1

5

Split Cover for 6x4 Outside Vertical Right Angle Fitting

FROVRASC6YL

Optional split cover for the outside vertical right angle fitting
FROVRA6X4YL. Snap-on feature allows cover to be
installed and removed with no tools required. Creates
radiused 19mm opening for easy access to add or remove
fibre cables.

1

5

6x4 Up Spout Fitting

FRUPS6X4YL

Allows cable to be directed upward out of the channel
deployed directly below racks and cabinets in underfloor
installations. Snaps directly onto the channel and can be
positioned to allow cables to be laid in. 25.4mm top bezel
included. Other fittings can be installed for specific
applications including FTR4X4YL and FIDT4X4BL.

1

5

6x4 to 4x4 

F

IBER

R

UNNER

Reducer Fitting

FRRF6FR4YL

Attaches any 6x4 

F

IBER

R

UNNER

fitting to channel to any 

4x4 

F

IBER

R

UNNER

fitting or channel. Accepts split cover

FRRF6FR4SCYL.

(1 pc.)

FRBC6X4YL

(1 pc.)

FRBC4X4YL

1

5

Split Cover for 6x4 to 4x4 

F

IBER

R

UNNER

Reducer Fitting

FRRF6FR4SCYL

Optional split cover for the 6x4 

F

IBER

R

UNNER

to 4x4

F

IBER

R

UNNER

reducer fitting FRRF6FR4YL. Snap-on

feature allows cover to be installed and removed with no
tools required. Creates radiused 19mm opening for easy
access to add or remove cables,

1

5

6x4 

F

IBER

R

UNNER

System to 4x4 

F

IBER

-D

UCT

Reducer Fitting

FRRF64YL

Attaches any 6x4 

F

IBER

R

UNNER

fitting or channel to the

4x4 

F

IBER

-D

UCT

channel S4X4YL6 or E4X4YL6. Includes

solid cover.

(1 pc.)

FRBC6X4YL

1

5

Innerduct Transition Fitting

FITF6X4

Metal fitting attaches to end of channel or fitting to transition
up to four pieces of 38mm inside diameter inner duct.
Hardware is included for installation. Black colour only.

1

10

Panduit-Pannet-html.html
background image

213

FR6TRBE12

FR6TRBE58

FR6TRBE12M 

R6TRBE58M

FR6TRBN12
FR6TRBN58

FR6TRBN12M
FR6TRBN58M

FR6USB

FR6ALB

FR6CS12
FR6CS58

FR6CS12M
FR6CS58M

FR6ACB12
FR6ACB58

FR6ACB12M
FR6ACB58M

4x4 and 6x4 

F

IBER

R

UNNER

Mounting Brackets

Part Number

Part Description

For Threaded 

Rod Size

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Existing Threaded Rod 

Q

UIK

L

OCK

Bracket for 6x4 and 4x4 Systems

FR6TRBE12

Used to support the 6x4 and 4x4 systems from existing
threaded rod installations. Bracket is secured to
threaded rod with two split nuts. The pre-assembled
slide clamps enable fast assembly to channel. Use
11.11mm nut driver on slide clamps.

1/2"

1

10

FR6TRBE58

5/8"

1

10

FR6TRBE12M

12 mm

1

10

FR6TRBE58M

16 mm

1

10

New Threaded Rod 

Q

UIK

L

OCK

Bracket for 6x4 and 4x4 Systems

FR6TRBN12

Used to support the 6x4 and 4x4 systems from any
new threaded rod installations. Bracket is secured to
threaded rod with two nuts. The pre-assembled slide
clamps enable fast assembly to channel. Use 11.11mm
nut driver on slide clamps.

1/2"

1

10

FR6TRBN58

5/8"

1

10

FR6TRBN12M

12 mm

1

10

FR6TRBN58M

16 mm

1

10

Under-Floor Pedestal 

Q

UIK

L

OCK

Bracket for 6x4 and 4x4 Systems

FR6USB

Used to support the 6x4 and 4x4 systems by attaching
to under-floor pedestals. (Contains all necessary
hardware.) Use on pedestals up to 25.4mm in diameter.
The pre-assembled slide clamps enable fast assembly
to channel. Use 11.11mm nut driver on slide clamps.

1

10

Adjustable Ladder 

Q

UIK

L

OCK

Bracket for 6x4 and 4x4 Systems

FR6ALB

Used to support the 6x4 and 4x4 systems attaching to
any 9.5mm x 38.1mm or 9.5mm x 50.8mm ladder rack
rail. Adjustable to 9 incremental positions from 101mm
to 304mm above or below the ladder rack. No threaded
rod required. The pre-assembled slide clamps enable
fast assembly to channel. Use 11.11mm nut driver on
slide clamps.

1

10

Centre Support 

Q

UIK

L

OCK

Bracket for 6x4 and 4x4 Systems

FR6CS12

Used to support the 6x4 and 4x4 systems from below
with new threaded rod. Bracket is secured to threaded
rod with two nuts. The pre-assembled slide clamps
enable fast assembly to channel. Use 11.11mm nut
driver on slide clamps. Also can be secured directly to
the top of cabinets.

1/2"

1

10

FR6CS58

5/8"

1

10

FR6CS12M

12 mm

1

10

FR6CS58M

16 mm

1

10

Top Support Adjustable "C" 

Q

UIK

L

OCK

Bracket for 6x4 and 4x4 Systems

FR6ACB12

Used to support the 6x4 and 4x4 systems from any
new threaded rod extending down directly from the
ceiling, grid or ladder rack system. Two position height
adjustments to accommodate system with or without
hinged cover. Bracket is secured to threaded rod with
two nuts. The pre-assembled slide clamps enable fast
assembly to channel. Use 11.11mm nut driver on 
slide clamps.

1/2"

1

FR6ACB58

5/8"

1

FR6ACB12M

12 mm

1

FR6ACB58M

16 mm

1

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

214

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

FLB12X20
FLB58X20

TR1-12-X
TR1-58-X

TRC18FR-X8

FR6LRB

FR6LB

F2PCLB12
F2PCLB58

F2PCLB12M
F2PCLB58M

FLB12X15
FLB58X15

FR6TB38
FR6TB12

FR6TB38M
FR6TB12M

4x4 and 6x4 

F

IBER

R

UNNER

Mounting Brackets (continued)

Part Number

Part Description

For Threaded 

Rod Size

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Trapeze 

Q

UIK

L

OCK

Bracket for 6x4 and 4x4 Systems

FR6TB38

Used to support the 6x4 and 4x4 systems by spanning
two threaded rod drops. Can be installed from above or
below. Bracket is secured to each threaded rod with 2
nuts. The pre-assembled slide clamps enable fast
assembly to channel. Use 11.11mm nut driver on 
slide clamps.

3/8"

1

10

FR6TB12

1/2"

1

10

FR6TB38M

10 mm

1

10

FR6TB12M

12 mm

1

10

Two Piece Ladder Rack Bracket for Attaching Threaded Rod 
to 38.1mm - 50.8mm Ladder Rack

F2PCLB12

Two piece bracket attaches to 9.5mm wide x 38.1mm
or 9.5mm wide by 50.8mm ladder rack rail. Bracket
halves slide into position and clamp together on the
ladder rack rail, which allows for a one-handed
assembly of the threaded rod (not included). Contains
bracket and hardware for attaching bracket to 
ladder rack.

1/2"

1

10

F2PCLB58

5/8"

1

10

F2PCLB12M

12 mm

1

10

F2PCLB58M

16 mm

1

10

Bracket for Attaching Threaded Rod to 38.1mm Ladder Rack

FLB12X15

Bracket attaches to 9.5mm x 38.1mm ladder rack rail.
Bracket accepts threaded rod (not included). Contains
bracket and hardware for attaching bracket to 
ladder rack.

1/2"

1

10

FLB58X15

5/8"

1

10

Bracket for Attaching Threaded Rod to 50.8mm Ladder Rack

FLB12X20

Bracket attaches to 9.5mm wide x 50.8mm ladder rack
rail. Bracket accepts threaded rod (not included).
Contains bracket and hardware for attaching bracket to
ladder rack.

1/2"

1

10

FLB58X20

5/8"

1

10

Threaded Rod in 305mm Lengths

TR1-12-X

Threaded rod can be used with various mounting
brackets. Length = 305mm

1/2"

10

50

TR1-58-X

5/8"

10

50

Threaded Rod Cover

TRC18FR-X8

Used to protect cabling from threaded rod.  Vertical slit
allows easy installation.  Material meets UL94V-0
specifications.  For indoor use only.

1/2" to 5/8"

10

100

Ladder Rack 

Q

UIK

L

OCK

Bracket for 6x4 and 4x4 Systems

FR6LRB

Used to support the 6x4 and 4x4 systems attaching
directly to any 9.5mm x 38.1mm or 9.5mm x 50.8mm
ladder rack rail. No threaded rod required. The pre-
assembled slide clamps enable fast assembly to
channel. Use 11.11mm nut driver on slide clamps.

1

10

"L" Wall Mount 

Q

UIK

L

OCK

Bracket for 6x4 and 4x4 Systems

FR6LB

Used to support the 6x4 and 4x4 systems attaching to
a wall or the front or back of an equipment rack. The
pre-assembled slide clamps enable fast assembly to
channel. Use 11.11mm nut driver on slide clamps.

1

10

Panduit-Pannet-html.html
background image

215

FR6RMBEIA

FEIAB58

FRRMBNF58

FR6ACAB

FRSTRCLIP

FRBB6-X

FRSLNKT12
FRSLNKT58

FRSLNKT12M
FRSLNKT58M

FTRB12
FTRB58

4x4 and 6x4 

F

IBER

R

UNNER

Mounting Brackets (continued)

Part Number

Part Description

For Threaded 

Rod Size

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

EIA/TIA Rack Mount 

Q

UIK

L

OCK

Bracket for 6x4 and 4x4 Systems

FR6RMBEIA

Used to support the 6x4 and 4x4 systems attaching to
the top of an equipment rack. Contains hardware to
mount to the top of EIA/TIA equipment racks. No
threaded rod required. The pre-assembled slide clamps
enable fast assembly to channel. Use 11.11mm nut
driver on slide clamps.

1

10

EIA/TIA Threaded Rod Mounting Bracket

FEIAB58

Bracket consists of two identical components that
clamp onto the crossmembers of standard EIA/TIA
racks and are secured with standard hex nuts and split
lockwashers (included) tightened onto a length of 5/8
diameter threaded rod (not included). The threaded rod
is positioned in the centre of the brackets providing a
vertical threaded rod stud to mount 

F

IBER

R

UNNER

and

F

IBER

-D

UCT

threaded rod mounting brackets onto.

5/8"

1

10

NetFrame Rack Mount 

Q

UIK

L

OCK

Bracket for 6x4 and 4x4 Systems

FRRMBNF58

Used to support the 6x4 and 4x4 systems attaching to
the top of 

N

ET

F

RAME

rack. (Contains all necessary

mounting hardware.) Bracket accepts 5/8 threaded rod.

5/8"

1

0

Adjustable Cabinet 

Q

UIK

L

OCK

Bracket for 6x4 and 4x4 Systems

FR6ACAB

Used to support the 6x4 and 4x4 systems attaching to
the top of cabinets. Adjustable from 108mm to 235mm
allowing rund to be levelled over uneven cabinet
heights. Also allows spillouts such as the vertical tee to
be positioned directly over cable inlets on cabinet tops.
Bracket is secured to the cabinet frame with through
bolts (not included). The pre-assembled slide clamps
enable fast assembly to channel. Use 11.11mm nut
driver on slide clamps.

1

0

Strut Metal Framing Bracket

FTRB12

Bracket attaches to strut metal framing. Contains
bracket and hardware for attaching threaded rod to
metal framing.

1/2"

1

10

FTRB58

5/8"

1

10

Strut Clip Kit

FRSTRCLIP

Strut mounting clip assembly allows 

F

IBER

R

UNNER

channel to be attached directly to standard 41.3mm
wide strut structures. Contains all hardware for
assembly. Bolts release with 11.1mm nut driver.

1

10

Snap Bracket Clip

FRBB6-X

Snap bracket enables the 6x4 

F

IBER

R

UNNER

channel

to be quickly and securely mounted. Contains all
hardware for assembly to any 

F

IBER

R

UNNER

6x4 and

4x4 bracket.

10

100

Split Locking Nut Kit

FRSLNKT12

Used to secure 

F

IBER

R

UNNER

mounting brackets

anywhere along pre-installed threaded rod. Split nuts
are opened, placed in desired position, closed 
and tightened.

1/2"

1

10

FRSLNKT58

5/8"

1

10

FRSLNKT12M

12 mm

1

10

FRSLNKT58M

16 mm

1

10

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

216

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

FRADC12X4BL

FRADC6X4

FRADC4X4BL

FRTYT68

FRWBS68

FADC4X4

FTDNS4X4

Adapters to Other Systems

*FiberGuide is a registered trademark of ADC Telecommunications, Inc.
**Lightguide is a trademark of the Hellerman Tyton Corporation.
***Lightpaths is a registered trademark of Warren & Brown Technologies Pty Ltd.

Part Number

Part Description

Couplers 
Required

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

Adapter from 12x4 

F

IBER

R

UNNER

System to ADC 12x4 FiberGuide*

FRADC12X4BL

Fitting that transitions from ADC’s 12x4 FiberGuide* System
to 12x4 

F

IBER

R

UNNER

System. Fitting has a black finish

and is made from metal. Attachment hardware is included.

(1 pc.)

FRBC12X4YL

1

5

Adapter from 6x4 

F

IBER

R

UNNER

System to ADC 6x4 FiberGuide*

FRADC6X4YL

Fitting that transitions from ADC’s 6x4 FiberGuide* System
to 6x4 

F

IBER

R

UNNER

System. Bolts release using 9.5mm

nut driver to allow coupler to be removed, if necessary.

1

5

Adapter from 4x4 

F

IBER

R

UNNER

System to ADC 4x4 FiberGuide*

FRADC4X4BL

Fitting that transitions from ADC’s 4x4 FiberGuide* System
to 4x4 

F

IBER

R

UNNER

System. Fitting has a black finish and

is made from metal. Attachment hardware is included.

(1 pc.)

FRBC4X4YL

1

5

Adapter from 6x4 

F

IBER

R

UNNER

System to Tyton 8x4 Lightguide**

FRTYT68

Fitting that transitions from Tyton 8x4 Lightguide** System to
6x4 

F

IBER

R

UNNER

System. Fitting has a black finish and is

made from metal. Attachment hardware is included.

(1 pc.)

FRBC6X4YL

1

5

Adapter from 6x4 

F

IBER

R

UNNER

System to Warren & Brown 8x4 Lightpaths***

FRWBS68

Fitting that transitions from Warren & Brown 8x4 Lightpaths
*** System to 6x4 

F

IBER

R

UNNER

System. Fitting has a

black finish and is made from metal. Attachment hardware is
included.

(1 pc.)

FRBC6X4YL

1

5

Adapter from 4x4 

F

IBER

-D

UCT

System to ADC 4x4 FiberGuide*

FADC4X4

Fitting that transitions from ADC’s 4x4 Fibre-Guide* Fibre
Cable Management System to 4x4 

F

IBER

-D

UCT

System.

Fitting has a black finish and is made from metal. Attachment
hardware is included.

1

10

Adapter from 4x4 

F

IBER

-D

UCT

System to Various 4x4 Systems

FTDNS4X4YL

Fitting that transitions from various 4x4 systems to 4x4 

F

IBER

-D

UCT

System. Attachment hardware is included.

1

5

Panduit-Pannet-html.html
background image

217

Notes

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

218

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Ladder Rack 

Q

UIK

L

OCK

Bracket for 6x4 and

4x4 Systems

Trapeze 

Q

UIK

L

OCK

Bracket for 6x4 and

4x4 Systems

Bracket for attaching

Threaded Rod to

Ladder Rack

"L" Wall Mount 

Q

UIK

L

OCK

Bracket for 6x4 and

4x4 Systems

22

8

17

18

3

19

4

10

7

6

21

2

13

20

4x4 

Routing System Roadmap

16

1

4x4 and 6x4 

F

IBER

R

UNNER

Mounting Brackets

5

Panduit-Pannet-html.html
background image

219

EIA Rack Mount 

Q

UIK

L

OCK

Bracket for 6x4 and

4x4 System

15

9

14

12

4x4 

F

IBER

R

UNNER

Channel (see page 220)

4x4 Snap-On Hinged Cover (see page 220)

4x4 Split Hinged Cover (see page 220)

4x4 

Q

UIK

L

OCK

Coupler (see page 221)

4x4 Horizontal Right Angle Fitting and
Optional Split Cover (see page 221)

4x4 Horizontal 45° Angle Fitting and Optional
Split Cover (see page 221)

4x4 Horizontal Tee Fitting and Optional Split
Cover (see page 222) 

4x4 Four Way Cross Fitting and Optional Split
cover (see page 222)

3-Sided BRC Trumpet Spill-Out for 4x4

F

IBER

R

UNNER

Exit (see page 222)

4x4 End Cap Fitting (see page 222)

4x4 

Q

UIK

L

OCK

Vertical Tee Fitting 

(see page 222)

2-Port Spillout to 1.5" (38mm) Inside Diameter
Corrugated Tubing (see page 223)

3-Sided Vertical Tee Trumpet Spillout
(see page 223)

Low Profile Reducer 4x4 to 2x2 for Vertical
Tee (see page 223)

Spill-Over Junction and Optional Cover
for 4x4 System (see page 224)

3-Sided BRC Trumpet Spillout for 2x2 Exit
(see page 224)

4x4 Inside Vertical 45° Angle Fitting
(see page 224)

4x4 Outside Vertical 45° Angle Fitting and
Optional Split Cover (see page 225)

4x4 Outside Vertical Right Angle Fitting and
Optional Split Cover (see page 225)

6x4 to 4x4 

F

IBER

R

UNNER

Reducer Fitting and

Optional Split Cover (see page 225)

4x4 

F

IBER

R

UNNER

System to 2x2 

F

IBER

-D

UCT

Reducer Fitting with Cover (see page 226)

4x4 

F

IBER

R

UNNER

System to 4x4 

F

IBER

-D

UCT

Reducer Fitting with Cover (see page 225)

1

2

3

4

5

6

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

NOTE: Additional 6x4 and 4x4 bracket applications, see pages 130-131

7

11

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

220

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

4x4 

F

IBER

R

UNNER

Routing System Channel and Covers

• Robust 4x4 system ideal for use with smaller cable counts
• Multiple spillout options provide versatility to mate to

various equipment and rack configurations

• QuikLock couplers and brackets reduce system installation

time dramatically

• Channel, covers, fittings and other non-metallic system

components made from V-0 flame class rated material

• UL Listed
• Compatible with all sizes of 

PANDUIT

F

IBER

R

UNNER

and

PANDUIT F

IBER

-D

UCT

routing systems, cable

management products and racks

• Compliant with the applicable tests in Telcordia 

GR-63-CORE Network Equipment Building 
Systems (NEBS)

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)
Order length required, in multiples of standard length increments.
Order number of Cable Retainers required, in multiples of Standard Package Quantity.

FR4X4

FRHC4

FRSHC4

FRCR4BL-X

112.7mm

128.3mm

11354mm

2

Cable Fills for 

F

IBER

R

UNNER

4x4 Cable Routing System

4x4 

F

IBER

R

UNNER

Routing System

SPEC

2258

MAX

3388

DIAMETER

1.6mm

The maximum amounts may vary according to the cable fill installation methods,
straightness of cables, etc.

SPEC= 40% cablefill — the recommended design in cable
capacity. Leaves room for future moves, adds and changes.

MAX= 60% cablefill — the maximum cable quantity
based on cable interweaving and packing factors.

System Type

F

IBER

R

UNNER

4x4 System

Area 

mm

2

11354

SPEC

1436

MAX

2154

SPEC

644

MAX

966

SPEC

37

MAX

56

SPEC

190

MAX

286

DIAMETER

2.0mm

DIAMETER

3.0mm

DIAMETER

12.5mm

DIAMETER

5.5mm

Fibre Cable

Data Grade

Cables

24 AWG UTP/CM

CAT5e 4 pr

Channel cutting instructions: For optimum results, use FRCUT miter box and saw. For larger quantities
use a plastic cutting saw blade for clean, burr-free cuts. Recommend: Carbide 80T or 100T; .090"
thickness, 3.2mm.

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

4x4 

F

IBER

R

UNNER

Channel

FR4X4YL6

Used to carry the cables horizontally throughout the system. Accepts
hinged cable retainers FRCR4BL-X, hinged cover FRHC4YL6 or split
hinged cover FRSHC4YL6. Use QuikLock couplers FRBC4X4YL to
attach channel and/or fittings.

6

36

4x4 Snap-On Hinged Cover

FRHC4YL6

Optional snap-on hinged cover for channel FR4X4YL6. Hinge feature
enables positioning of cover at angles between 30° to 90°.

6

36

4x4 Split Hinged Cover

FRSHC4YL6

Optional split hinged cover for the channel FR4X4YL6. Creates
radiused 19mm opening for easy access to add or remove cables.
Snap-on hinge feature enables positioning of cover at angles between
30° and 90°.

6

36

Cable Retainer for 4x4 System

FRCR4BL-X

Cable retainer holds cable in the channel when cover is not used.
Install anywhere on channel, near the coupler of every 457mm. Black
colour only.

10

100

Panduit-Pannet-html.html
background image

221

4x4 F

IBER

R

UNNER

Q

UIK

L

OCK

Coupler

• Pre-assembled to provide fast mechanical assembly 

of components

• No tools required for installation, bolts loosen for 

component disassembly

FRBC4X4

FRRA4X4

FRRASC4

FRH454X4

FRH45SC4

FRT4X4

4x4 

F

IBER

R

UNNER

System Fittings

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

• Minimum 50.8mm bend radius control fittings
• Protects against signal loss and performance degradation
• Fittings assemble using FRBC couplers

• Optional split covers snap onto each fitting
• Covers feature 19mm gap to allow cable to be laid in

Part Number

Part Description

Std.

Pkg.

Qty.

Std.

Ctn. Qty.

FRBC4X4YL

Pre-assembled coupler quickly joins 2 sections of channel
and/or fittings. Mechanically attaches without tightening bolts.
Bolts release using 3/8" nut driver to allow coupler to be
removed if necessary.

1

5

Part Number

Part Description

Couplers 
Required

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

4x4 Horizontal Right Angle Fitting

FRRA4X4YL

Attaches to 4x4 channel and/or fitting to create a 90°
horizontal turn from a straight horizontal run. Accepts
optional split cover FRRASC4YL.

(2 pcs.)

FRBC4X4YL

1

5

Split Cover for 4x4 Horizontal Right Angle Fitting

FRRASC4YL

Optional split cover for the horizontal right angle fitting
FRRA4X4YL. Snap-on feature allows cover to be
installed and removed with no tools required. Creates
radiused 19mm opening for easy access to add or
remove cables.

1

5

4x4 Horizontal 45° Angle Fitting

FRH454X4YL

Attaches to 4x4 channel and/or fittings to create a 45°
horizontal turn from a straight horizontal run. Accepts
optional split cover FRH45SC4YL.

(2 pcs.)

FRBC4X4YL

1

5

Split Cover for 4x4 Horizontal 45° Angle Fitting

FRH45SC4YL

Optional split cover for the horizontal 45° angle fitting
FRH454X4YL. Snap-on feature allows cover to be
installed and removed with no tools required. Creates
radiused 19mm opening for easy access to add or
remove fibre cables.

1

5

4x4 Horizontal Tee Fitting

FRT4X4YL

Attaches to 4x4 channel and/or fittings to create a 90°
horizontal branch from straight horizontal runs. Accepts
optional split cover FRTSC4YL.

(3 pcs.)

FRBC4X4YL

1

5

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

222

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

FREC4X4

FRVT4X4

FR1.5IDE

FRTSC4

FRFWC4X4

FRFWCSC4

FRTR4X4

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

4x4 

F

IBER

R

UNNER

System Fittings (continued)

Part Number

Part Description

Couplers 
Required

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

Split Cover for 4x4 Horizontal Tee Fitting

FRTSC4YL

Optional split cover for the horizontal tee fitting
FRT4X4YL. Snap-on feature allows cover to be
installed and removed with no tools required. Creates
radiused 19mm opening for easy access to add or
remove cables.

1

5

4x4 Four Way Cross Fitting

FRFWC4X4YL

Attaches to 4x4 channel and/or fittings to create a
horizontal four way cross intersection. Accepts optional
split cover FRFWCSC4YL.

(4 pcs.)

FRBC4X4YL

1

5

Split Cover for 4x4 Four Way Cross Fitting

FRFWCSC4YL

Optional split cover for the four way cross fitting
FRFWC4X4YL. Snap-on feature allows cover to be
installed and removed with no tools required. Creates
radiused 19mm opening for easy access to add or
remove cables.

1

5

3-Sided BRC Trumpet Spill-Out for 4x4 

F

IBER

R

UNNER

Exit

FRTR4X4YL

Used to limit the bend of the fibre cable to 50.8mm
when exiting from 4x4 

F

IBER

R

UNNER

channel or a

F

IBER

R

UNNER

horizontal tee fitting.

(1 pc.)

FRBC4X4YL

1

5

4x4 End Cap Fitting

FREC4X4YL

Used for closing off open ends of the channel or
fittings. No coupler required, push-on installation.

1

5

4x4 

Q

UIK

L

OCK

Vertical Tee Fitting

FRVT4X4YL

Attaches to 4x4 channel and/or fittings to create a 90°
vertical drop from a horizontal run. Hinged door
included. Accepts FTR4X4YL, FIDT4X4BL, S4X4YL6 or
E4X4YL6 directly. Accepts optional snap-on cover
FRHC4YL6 in conjunction with channel.

(2 pcs.)

FRBC4X4YL

1

5

1 Port Spillout Side Exit to 38mm Inside Diameter Corrugated Tubing

FR1.5IDEYL

Used to route cable into 38mm diameter split
corrugated tubing directly through a hole cut in the side
wall of the 4x4, 6x4 and 12x4 

F

IBER

R

UNNER

channel

or 4x4 

F

IBER

-D

UCT

channel. Provides 25.4mm bend

radius control at the exit. Securely holds split
corrugated tubing to ensure system integrity and 
easy access to add or remove cables. Includes 
drilling template.

1

5

Panduit-Pannet-html.html
background image

223

FRIDT4X4

FIDT4X4BL

FTR4X4

FRLPR42BL

FRSP

FRSP4C

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

4x4 

F

IBER

R

UNNER

System Fittings (continued)

Part Number

Part Description

Couplers 
Required

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

2 Port Spillout to 38mm Inside Diameter Corrugated Tubing

FRIDT4X4YL

Used to route cable into one or two pieces of 38mm
diameter split corrugated tubing. Requires coupler to be
used with 4x4 

F

IBER

R

UNNER

fitting. Used with and

4x4 

F

IBER

R

UNNER

fitting. Securely holds corrugated

split tubing to ensure system integrity and easy access
to add or remove cables.

(1 pc.)

FRBC4X4YL

1

5

2-Port Spillout to 38mm Inside Diameter Corrugated Tubing

FIDT4X4BL

Used to route cable into one or two pieces of 38mm
diameter split corrugated tubing. Used with
FRVT6X4YL, FRVT4X4YL or FVT4X4YL. Securely
holds corrugated split tubing to ensure system integrity
and easy access to add or remove cables. Black 
colour only.

1

5

3-Sided Vertical Tee Trumpet Spillout

FTR4X4YL

Used to limit the bend raidus of the cable to 50.8mm
when exiting from a 4x4 or 6x4 

F

IBER

R

UNNER

vertical

tee fitting and 4x4 

F

IBER

-D

UCT

fittings.

1

5

Low Profile Reducer 4x4 to 2x2 for Vertical Tee

FRLPR42BL

Assembled into the 6x4 vertical tee FRVT6X4YL or 4x4
vertical tee FRVT4X4YL with an audible snap, the
FRLPR42BL allows for the transition to 2x2 

F

IBER

-D

UCT

channel with minimal space required. No

tools required for assembly. Black colour only.

1

5

Spill-Over Junction with 2x2 Exit

FRSPYL

Assembles onto 4x4, 6x4 or 12x4 

F

IBER

R

UNNER

channel spilling over the side into a 2x2 vertical
channel, fitting or corrugated tube. Mounts directly to
existing installation with no alteration required.
Mounting hardware provided for secure attachment.

1

Spill-Over Junction Cover for 4x4 System

FRSP4CYL

Used to fully enclose 4x4 channel in conjunction with
the spill-over junction FRSPYL. Cover snaps onto the
channel base. Hinged feature allows easy access to
add or remove cables.

1

5

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

224

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

FTR2X2

FIDT2X2

FRIV454X4

FROV454X4

FRSP4

FRSP44C

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

4x4 

F

IBER

R

UNNER

System Fittings (continued)

Part Number

Part Description

Couplers 
Required

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

Spill-Over Junction with 4x4 Exit

FRSP4YL

Assembles onto 4x4, 6x4, or 12x4 

F

IBER

R

UNNER

channel spilling over the side into a 4x4 vertical exit.
Requires coupler to attach 4x4 

F

IBER

R

UNNER

channel

and fittings to vertical exit. Mounts directly to existing
installation with no alteration required. Mounting
hardware provided for secure attachment.

(1) 

FRBC4X4YL

1

Spill-Over Junction Cover for 4x4 System

FRSP44CYL

Used to fully enclose the 4x4 channel in conjunction
with the spill-over junction FRSP4YL. Cover snaps onto
the channel base. Hinged feature allows easy access
to add or remove cables.

1

5

3-Sided BRC Trumpet Spillout for 2x2 Exit

FTR2X2YL

Used to limit the bend of the fibre cable to 50mm when
exiting from a 

F

IBER

R

UNNER

spill-over fitting FRSPYL

or from 2x2 

F

IBER

-D

UCT

channel.

1

5

1-Port Spillout to 38mm Inside Diameter Corrugated Tubing

FIDT2X2YL

Used to route cable into one piece of 38.1mm diameter
split corrugated tubing. Used with 

F

IBER

R

UNNER

spill-over fitting FRSPYL, 2x2 

F

IBER

-D

UCT

fittings and

the 2x2 

F

IBER

R

UNNER

hinged channel. Securely holds

split corrugated tubing to ensure system integrity and
easy access to add or remove cables.

1

5

4x4 Inside Vertical 45° Angle Fitting

FRIV454X4YL

Attaches to 4x4 channel and/or fitting to create a 45°
upward angle from a straight horizontal run. Used with
outside vertical 45° angle fitting FROV454X4YL to
change level of a straight horizontal run. Includes 
split cover.

(2 pcs.)

FRBC4X4YL

1

5

4x4 Outside Vertical 45° Angle Fitting

FROV454X4YL

Attaches to 4x4 channel and/or fitting to create a 45°
upward angle from a straight horizontal run. Used with
outside vertical 45° angle fitting FRIV454X4YL to
change level of a straight horizontal run. Accepts
optional split cover FROV45SC4YL.

(2 pcs.)

FRBC4X4YL

1

5

Panduit-Pannet-html.html
background image

225

FROVRA4X4

FROVRASC4

FRUPS4X4

FRRF6FR4

FRRF6FR4SC

FROV45SC4

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

4x4 

F

IBER

R

UNNER

System Fittings (continued)

Part Number

Part Description

Couplers 
Required

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

Split Cover for 4x4 Outside Vertical 45° Angle Fitting

FROV45SC4YL

Optional split cover for the outside vertical 45° angle
fitting FROV454X4YL. Snap-on feature allows cover to
be installed and removed with no tools required.
Creates radiused 19mm opening for easy access to
add and remove cables.

1

5

4x4 Outside Vertical Right Angle Fitting

FROVRA4X4YL

Attaches to 4x4 channel and/or fittings to create a 90°
vertical turn down from a straight horizontal run.
Accepts optional split cover FROVRASC4YL.

(2 pcs.)

FRBC4X4YL

1

5

Split Cover for 4x4 Outside Vertical Right Angle Fitting

FROVRASC4YL

Optional split cover for the outside vertical right angle
fitting FROVRA4X4YL. Snap-on feature allows cover to
be installed and removed with no tools required.
Creates radiused 19mm opening for easy access to
add or remove cables.

1

5

4x4 Up Spout Fitting

FRUPS4X4YL

Allows cable to be directed upward out of the channel
deployed directly below racks and cabinets in
underfloor installations. Snaps directly onto the channel
and can be positioned to allow cables to be laid in. A
25.4mm top bezel is included. Other fittings can be
installed for specific applications including FTR4X4YL
and FIDT4X4BL.

1

5

6x4 to 4x4 

F

IBER

R

UNNER

Reducer Fitting

FRRF6FR4YL

Attaches any 6x4 

F

IBER

R

UNNER

fitting to channel to

any 4x4 

F

IBER

R

UNNER

fitting or channel. Accepts split

cover FRRF6FR4SCYL.

(1 pc.)

FRBC6X4YL

(1 pc.)

FRBC4X4YL

1

5

Split Cover for 6x4 to 4x4 

F

IBER

R

UNNER

Reducer Fitting

FRRF6FR4SCYL

Optional split cover for the 6x4 

F

IBER

R

UNNER

to 4x4

F

IBER

R

UNNER

reducer fitting FRRF6FR4YL. Snap-on

feature allows cover to be installed and removed with
no tools required. Creates radiused 19mm opening for
easy access to add or remove cables,

1

5

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

226

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black)

FRRF4FD2

FRRF4FD4

4x4 

F

IBER

R

UNNER

System Fittings (continued)

Std. 
Ctn. 
Qty.

Std. 

Pkg. 

Qty.

Couplers 
Required

Part Description

Part Number

4x4 

F

IBER

R

UNNER

to 2x2 

F

IBER

-D

UCT

Reducer Fitting with Cover

FRRF4FD2YL

Attaches any 4x4 

F

IBER

R

UNNER

fitting or channel to

the 2x2 

F

IBER

-D

UCT

channel, S2X2YL6 or E2X2YL6.

Includes solid cover.

(1 pc.)

FRBC4X4YL

1

5

4x4 

F

IBER

R

UNNER

to 4x4 

F

IBER

-D

UCT

Reducer Fitting with Cover

FRRF4FD4YL

Attaches any 4x4 

F

IBER

R

UNNER

fitting or channel to

the 4x4 

F

IBER

-D

UCT

channel, S4X4YL6 or E4X4YL6.

Includes solid cover.

(1 pc.)

FRBC4X4YL

1

5

Panduit-Pannet-html.html
background image

227

F

IBER

R

UNNER

Accessories

FRCUT

FR38DR

FR716DR

FR38BIT 

FR716BIT

FRUIB-X

FR516DR

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Mitre Box and Saw

FRCUT

Used to cut 2x2, 4x4 and 6x4 

F

IBER

R

UNNER

channel and hinged

cover, 4x4 

F

IBER

-D

UCT

channel and cover and 2x2 

F

IBER

-D

UCT

channel and cover.

1

3/8 Nut Driver

FR38DR

Used to disassemble 4x4, 6x4 and 12x4 

F

IBER

R

UNNER

couplers 

when required.

1

10

5/16 Nut Driver

FR516DR

Used to disassemble 2x2 

F

IBER

R

UNNER

couplers when required.

1

10

7/16 Nut Driver

FR716DR

Used to assemble 

Q

UIK

L

OCK

bracket slide clamps

1

10

3/8 Nut Driver Bit

FR38BIT

Nonmagnetic nut driver bit for power tools. Shank is 6.35mm hex. 
Used to disassemble 4x4, 6x4 and 12x4 

F

IBER

R

UNNER

couplers 

when required.

1

10

7/16 Nut Driver Bit

FR716BIT

Nonmagnetic nut driver bit for power tools. Shank is 6.35mm hex. Used
to assemble 

Q

UIK

L

OCK

bracket slide clamps.

1

10

Universal Innerduct Bracket

FRUIB-X

Used to secure any size corrugated tubing or inner-duct to any surface
including equipment racks and channel or fittings. Two 6.3mm holes
must be drilled through to secure brackets.

10

100

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

228

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Strut Metal Framing

Bracket

New Threaded Rod

Bracket for 

F

IBER

-D

UCT

System

Bracket for

Attaching Threaded

Rod to 1 1/2"

Ladder Rack

Under-Floor

Pedestal Bracket for 

F

IBER

-D

UCT

System

Top Rail of Rack
Support Bracket

4

3

2

18

9

11

16

3

1

5

7

12

13

2x2

Routing System Roadmap

Two Piece Ladder Rack

Bracket for Attaching

Threaded Rod to 1 1/2"-

2" Ladder Rack

Existing Threaded Rod

Bracket for 

F

IBER

-D

UCT

System

"L" Wall Mount Bracket
for 

F

IBER

-D

UCT

System

14

F

IBER

-D

UCT

Mounting Brackets

Panduit-Pannet-html.html
background image

229

Ladder Rack Bracket

for 

F

IBER

-D

UCT

System

Adjustable "Z"

Bracket 

15

10

8

17

2x2 

F

IBER

R

UNNER

Hinged Channel 

2x2 

F

IBER

R

UNNER

Hinged Slotted Channel 

2x2 

F

IBER

R

UNNER

Hinged Snap-On Cover

2x2 

Q

UIK

L

OCK

Coupler

2x2 Horizontal Right Angle Fitting                

2x2 Horizontal Tee Fitting

2x2 Four Way Cross Fitting

2x2 End Cap Fitting

2x2 Vertical Tee Fitting

1-Port Spillout to 1.5" (38mm) Inside
Diameter Corrugated Tubing

2x2 Inside Vertical 45° Angle Fitting 

2x2 Outside 45° Angle Fitting

2x2 Inside Vertical Right Angle Fitting

2x2 Outside Vertical Right Angle Fitting

4x4 

F

IBER

-D

UCT

to 2x2 

F

IBER

-D

UCT

Reducer Fitting 

4x4 

F

IBER

R

UNNER

to 2x2 

F

IBER

-D

UCT

Reducer Fitting

2x2 Hinged Channel 1" Bend Radius
Control Fitting

2

3

4

5

6

7

8

9

10

12

14

15

16

17

18

3-Sided BRC Trumpet Spillout for 2x2 Exit

11

1

13

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

230

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

2x2 

F

IBER

R

UNNER

Routing System Channels and Cover

• 2x2 system ideal for use with smaller cable counts
• Multiple spillout options provide versatility to mate to 

various equipment and rack configurations

• QuikLock couplers reduce system installation 

time dramatically

• Channel, covers, fittings and other non-metallic system

components made from V-0 flame class rated material

• UL Listed

• Compatible with all sizes of 

PANDUIT

F

IBER

R

UNNER

and 

PANDUIT F

IBER

-D

UCT

routing systems, cable 

management products and racks

• 2x2 

F

IBER

R

UNNER

Hinged and Slotted Channels can be

used with 2x2 Fibre-Duct fittings (see pages XX and XX)
and brackets (see page XX-XX)

• Compliant with the applicable tests in Telcordia 

GR-63-CORE Network Equipment Building Systems

For other colour replace suffix YL (Yellow) with OR (Orange) and BL (Black)
Order number of metres required, in multiples of standard length increments.

HS2X2

H2X2

HC2

50.8

55.1

2193 mm

2

Channel cutting instructions: For optimum results, use FRCUT miter box and saw. For larger
quantities use a plastic cutting saw blade for clean, burr-free cuts. Recommend: Carbide 80T
or 100T; 2.29mm thickness, 3.2mm.

The maximum amounts may vary according to the cable fill installation 
methods, straightness of cables, etc.

SPEC= 40% cablefill — the recommended design in cable
capacity. Leaves room for future moves, adds and changes.

MAX= 60% cablefill — the maximum cable quantity
based on cable interweaving and packing factors.

Cable Fills for 

F

IBER

R

UNNER

2x2 Cable Routing System

2x2

F

IBER

R

UNNER

Routing System

SPEC

436

MAX

654

DIAMETER

1.6mm

System Type

F

IBER

R

UNNER

2x2 System

Area 

mm

2

2193

SPEC

277

MAX

416

SPEC

124

MAX

186

SPEC

7

MAX

10

SPEC

36

MAX

55

DIAMETER

2.0mm

DIAMETER

3.0mm

DIAMETER

12.5mm

DIAMETER

5.5mm

Fibre Cable

Data Grade

Cables

24 AWG UTP/CM

CAT5e 4 pr

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

2x2 

F

IBER

R

UNNER

Hinged Channel

HS2X2YL6NM

Used to carry the cables throughout the system. Accepts hinged
cover HC2YL6. Use 

Q

UIK

L

OCK

coupler FBC2X2YL to attach

channel and/or fittings.

6

120

2x2 

F

IBER

R

UNNER

Hinged Slotted Channel

H2X2YL6

Used to carry the cables vertically to the front or the sides of
equipment racks throughout the system. Accepts hinged cover
HC2YL6. Extra supports required when used in horizontal
applications. Use 

Q

UIK

L

OCK

coupler FBC2X2YL to attach

channel and/or fittings.

6

120

2x2 Snap-On Hinged Cover

HC2YL6

Optional snap-on cover for hinged channel HS2X2YL6 or
H2X2YL6. The innovative cover can hinge open to 90° from either
side of the channel and be removed completely if desired.

6

120

Panduit-Pannet-html.html
background image

231

2x2 

F

IBER

R

UNNER

Q

UIK

L

OCK

Coupler

• Pre-assembled to provide fast mechanical assembly 

of components

• No tools required for installation, bolts loosen for 

component disassembly

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black) 

FBC2X2

2x2 

F

IBER

R

UNNER

System Fittings

For other colour replace suffix YL (Yellow) with OR (Orange) or BL (Black) 

FHDEC2X2

FVTHD2X2

FIDT2X2

TRC2HDBL

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

FBC2X2YL

Pre-assembled coupler quickly joins two sections of hinged
channel and/or fittings. Mechanically attaches without tightening
bolts. Bolts release using 7.9mm nut driver to allow coupler to be
removed if necessary.

1

5

Part Number

Part Description

Couplers 
Required

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

2x2 End Cap Fitting

FHDEC2X2YL

Used for closing off open ends of the hinged
channel or fittings. No coupler required. Push-on
installation.

1

5

2x2 Vertical Tee Fitting

FVTHD2X2YL

Attaches to 2x2 channel to create a 90° vertical drop
from a horizontal run. Hinged door included. Accepts
channel cover in conjunction with channel. Use

Q

UIK

L

OCK

coupler FBC2X2YL with HS2X2YL6 or

H2X2YL6 channels. Use snap rivets NR2WH-L or
bolts F14PN-L with S2X2YL6 or E2X2YL6 channels.
Also accepts FIDT2X2YL.

(2 pcs.)

FBC2X2YL

1

5

1-Port Spillout to 38mm Inside Diameter Corrugated Tubing

FIDT2X2YL

Used to route cable into one piece of 38.1mm
diameter split corrugated tubing. Used with

F

IBER

R

UNNER

spill-over fitting FRSPYL, 2x2 

F

IBER

-D

UCT

fittings and the 2x2 

F

IBER

R

UNNER

hinged channel. Securely holds split corrugated
tubing to ensure system integrity and easy access to
add or remove cables.

1

5

2x2 

F

IBER

R

UNNER

Bend Radius Control Trumpet

TRC2HDBL

Bend radius control trumpet for exiting at the
sidewall of 2 wall heights of Type H Hinged Cover
Wiring Duct channels. Black colour only.

1

10

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

232

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Notes

Panduit-Pannet-html.html
background image

233

The 2x2 and 4x4 

F

IBER

-D

UCT

Routing Systems are comprised of channel, fittings and brackets

designed to segregate, route and protect fibre optic and copper cabling to and between racks

within the telecommunications room.

Two system sizes available: 4x4 and 2x2

Minimum 50.8mm bend radius fittings protect
against signal loss due to excessive cable bends

Optimized for use with 

P

AN

-N

ET

Network

Connectivity System

Snap-on non-slip covers 

Compatible with 

PANDUIT F

IBER

R

UNNER

12x4, 6x4,

4x4 and 2x2 Routing Systems

F

IBER

-D

UCT

R

OUTING

S

YSTEM

The 

PANDUIT

Network Connectivity Group provides leading solutions for cable routing. These

routing products are compatible with our cable management solutions increasing your ability to

maintain an orderly and clean work environment, implement quick and easy moves, adds and

changes and maintain the integrity of your fibre and copper cabling plant in order to maximise

long term performance.

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

23

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Strut Metal Framing

Bracket

Existing Threaded

Rod Bracket for

F

IBER

-D

UCT

System

New Threaded Rod

Bracket for 

F

IBER

-D

UCT

System

Adjustable "Z"

Bracket 

Bracket for Attaching

Threaded Rod to 

1 1/2" Ladder Rack

Under-Floor Pedestal

Bracket for 

F

IBER

-D

UCT

System

Top Rail of Rack

Support Bracket

2x2 and 4x4  F

IBER

-D

UCT

Routing Systems Roadmap

Ladder Rack

Bracket for

F

IBER

-D

UCT

System

"L" Wall Mount

Bracket for

F

IBER

-D

UCT

System

14

13

12

1

5

15

12

1

8

16

15

11

10

9

8

7

6

4

3

2

9

15

2

13

8

11

8

10

12

15

F

IBER

-D

UCT

Mounting Brackets

10

16

Panduit-Pannet-html.html
background image

23

Coupler Fitting (see page 237)

End Cap Fitting (see page 237)

Four Way Cross Fitting (see page 237)

Inside Vertical Right Angle (see page 238)

Inside Vertical 45° Angle (see page 238)

Outside Vertical 45° Angle (see page 238)

Horizontal Tee Fitting (see page 237)

Vertical Tee Fitting (see page 237)

Right Angle Fitting (see page 238)

Reducer Fitting (see page 238)

Mounting Kit for New Thd. Rod Assembly (see page 240)

Bracket for Attaching Threaded Rod to Ladder Rack (see page 240)

Ladder Rack Bracket (see page 241)

F

IBER

-D

UCT

Channel (see page 242)

F

IBER

-D

UCT

Slotted Channel (see page 243)

Outside Vertical Right Angle (see page 238)

2

3

4

5

6

7

8

9

10

12

14

15

16

11

1

13

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

23

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

2x2 and 4x4 F

IBER

-D

UCT

Routing Systems 

• Channel, covers, fittings and other non-metallic system

components made from V-0 flame class rated material

• Snap on non-slip covers

• UL Listed
• Compatible with 

PANDUIT

F

IBER

R

UNNER

2x2, 4x4, 6x4 

and 12x4 Routing Systems

NOTE: Available with mounting holes. To order, delete NM from the part number.
For fastest installation use NR2WH-L or NR4BL-L Snap Rivets.
For other colour replace suffix YL (Yellow) with OR (Orange).
Order number length required, in multiples of standard length increments.

28

99

57.1mm

2580mm

2

53.3mm

System Type

F

IBER

-D

UCT

2x2 System

Area

mm

2

2580

SPEC

326

MAX

490

SPEC

146

MAX

219

SPEC

8

MAX

13

SPEC

43

MAX

65

DIAMETER

2.0mm

DIAMETER

3.0mm

DIAMETER

12.5mm

DIAMETER

5.5mm

Fibre Cable

Data Grade

Cables

24 AWG UTP/CM

CAT5e 4 pr

F

IBER

-D

UCT

4x4 System

10322

1306

1959

585

878

34

50

173

260

107.9mm

10322mm

2

The maximum amounts may vary according to the cable fill installation methods,
straightness of cables, etc.

SPEC= 40% cablefill —

the recommended design in cable

capacity. Leaves room for future moves, adds and changes.

MAX= 60% cablefill —

the maximum cable quantity

based on cable interweaving and packing factors.

Cable Fills for 2x2 and 4x4 F

IBER

-D

UCT

Routing System

903

DIAMETER

1.6mm

Channel cutting instructions: 

For optimum results, use FRCUT miter box and saw. For larger

quantities use a plastic cutting saw blade for clean, burr-free cuts. Recommend: Carbide 80T or 100T;
2.29mm thickness, 3.2mm kerf.

S2x2
S4x4

E2x2
E4x4

Part Number

Part Description

System Size

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

F

IBER

-D

UCT

Channel

L

Used to carry the cables throughout the 

F

IBER

-D

UCT

routing system. Accepts cover C2YL6.

Cover sold separately.

2x2

6

120

L

Used to carry the cables throughout the 

F

IBER

-D

UCT

routing system. Accepts cover C4YL6.

Cover sold separately.

4x4

6

60

F

IBER

-D

UCT

Slotted Channel

L

Used to carry the cables vertically to the front or the
back of equipment racks throughout the system.
Accepts cover C2YL6. Extra supports required
when used in horizontal applications. 
Cover sold separately.

2x2

6

120

L

Used to carry the cables vertically to the front or the
back of equipment racks throughout the system.
Accepts cover C4YL6. Extra supports required
when used in horizontal applications. 
Cover sold separately.

4x4

6

60

F

IBER

-D

UCT

Cover

L

Cover for 

F

IBER

-D

UCT

channel and 

F

IBER

-D

UCT

slotted channel. Non-slip cover design incorporates
integral high friction lining to inhibit cover movement.

2x2

6

120

L

Cover for 

F

IBER

-D

UCT

channel and 

F

IBER

-D

UCT

slotted channel. Non-slip cover design incorporates
integral high friction lining to inhibit cover movement.

4x4

6

120

Panduit-Pannet-html.html
background image

23

F

IBER

-D

UCT

System Fittings

FCF2X2
FCF4X4

FRA2X2
FRA4X4

FFWC2X2
FFWC4X4

FT2X2
FT4X4

FEC2X2
FEC4X4

FVTHD2X2

FVT4X4

FIDT2X2

FIDT4X4BL

FTR4X4

For other colour replace suffix YL (Yellow) with OR (Orange).
Fittings include 7.9mm assembly holes for fast mechanical fastening.

Part Number

Part Description

System Size

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Coupler Fitting

L

Used to join two sections of duct together. 

F

IBER

-D

UCT

coupler is not required at each fitting

connection.

2x2

1

5

L

4x4

1

5

Horizontal Right Angle Fitting

L

Attaches to channel to create a 90° horizontal turn
from a straight horizontal run. Cover included.

2x2

1

5

L

4x4

1

5

Horizontal Tee Fitting

L

Attaches to channel to create a 90° horizontal
branch from a straight horizontal run. 
Cover included.

2x2

1

5

L

4x4

1

5

Four Way Cross Fitting

L

Attaches to channel to create a horizontal four way
cross intersection. Cover included.

2x2

1

5

L

4x4

1

5

End Cap Fitting

L

4x4

1

5

2x2 Vertical Tee Fitting

D

L

Attaches to 2x2 channel to create a 90° vertical
drop from a horizontal run. Hinged door included.
Accepts channel cover in conjunction with channel.
Use

Q

UIK

L

OCK

coupler FBC2X2YL with

HS2X2YL6 or H2X2YL6 channels.Use snap rivets
NR2WH-L or bolts F14PN-L with S2X2YL6 or
E2X2YL6 channels. Also accepts FIDT2X2YL.

2x2

1

5

Vertical Tee Fitting

L

Attaches to channel to create a 90° vertical drop
from a horizontal run. Accepts FIDT4X4BL,
FTR4X4YL, S4X4YL6 or E4X4YL6 directly.

4x4

1

5

1-Port Spillout to 38mm Inside Diameter Corrugated Tubing

D

L

Used to route cable into one piece of 38.1mm
diameter split corrugated tubing. Used with

F

IBER

R

UNNER

spill-over fitting FRSPYL, 2x2 

F

IBER

-D

UCT

fittings and the 2x2 

F

IBER

R

UNNER

hinged channel. Securely holds split corrugated
tubing to ensure system integrity and easy access
to add or remove cables.

2x2

1

5

2-Port Spillout to 38mm Inside Diameter Corrugated Tubing

D

BL

Used to route cable into one or two pieces of 38mm
diameter split corrugated tubing. Used with
FRVT6X4YL, FRVT4X4YL or FVT4X4YL. Securely
holds corrugated split tubing to ensure system
integrity and easy access to add or remove cables.
Black colour only.

4x4

1

5

3-Sided Vertical Tee Trumpet Spillout

L

Used to limit the bend raidus of the cable to
50.8mm when exiting from a 4x4 or 6x4

F

IBER

R

UNNER

vertical tee fitting and 4x4 

F

IBER

-D

UCT

fittings.

4x4

1

5

L

Used for closing off open ends of the channel. No
coupler required, push-on installation.

2x2

1

5

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

238

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

For other colour replace suffix YL (Yellow) with OR (Orange).
Fittings include 7.9mm assembly holes for fast mechanical fastening.

F

IBER

-D

UCT

System Fittings (continued)

FTR2X2

FIV452X2
FIV454X4

FOV452X2
FOV454X4

FIVRA2X2
FIVRA4X4

FOVRA2X2
FOVRA4X4

FRF42

FRF4544BL

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.

System Size

Part Description

Part Number

3-Sided BRC Trumpet Spillout for 2x2 Exit

L

Used to limit the bend of the fibre cable to 50mm
when exiting from a 

F

IBER

R

UNNER

spill-over fitting

FRSPYL or from 2x2 

F

IBER

-D

UCT

channel.

2x2

1

5

Inside Vertical 45° Angle Fitting

L

Attaches to channel to create a 45° upward angle
from a straight horizontal run. Used with outside
vertical 45° angle fitting FOV452X2YL or
FOV454X4YL to change level of straight horizontal
runs. Cover included.

2x2

1

5

L

4x4

1

5

Outside Vertical 45° Angle Fitting

O

L

Attaches to channel to create a 45° downward angle
from a straight horizontal run. Used with inside
vertical 45° angle fitting FIV452X2YL or
FIV454X4YL to change level of straight horizontal
runs. Cover included.

2x2

1

5

O

L

4x4

1

5

Inside Vertical Right Angle Fitting

L

Attaches to channel to create a 90° upward angle
from a straight horizontal run. Used with outside
vertical 90° angle fitting FOVRA2X2YL or
FOVRA4X4YL to change level of straight horizontal
runs. Cover included.

2x2

1

5

L

4x4

1

5

Outside Vertical Right Angle Fitting

O

L

Attaches to channel to create a 90° downward angle
from a straight horizontal run. Used with inside
vertical 90° angle fitting FIVRA2X2YL or
FIVRA4X4YL to change level of straight horizontal
runs. Cover included.

2x2

1

5

O

L

4x4

1

5

4x4 to 2x2 F

IBER

-D

UCT

Reducer Fitting

L

Joins any 4x4 

F

IBER

-D

UCT

fitting to the 2x2 

F

IBER

-D

UCT

channel, S2X2YL6 or E2X2YL6.

Includes cover.

2x2
4x4

1

5

4x4 F

IBER

-D

UCT

Channel to 4x5 Standard Vertical Slotted Duct Fitting

BL

Connects 4x4 

F

IBER

-D

UCT

channel to 4x5

standard vertical slotted duct. Hardware for
attaching is included. Black colour only.

4x4

1

5

Panduit-Pannet-html.html
background image

239

F

IBER

-D

UCT

Bend Radius Control Trumpet

• Provides method to transition cabling into rack system
• Maintains 25.4mm bend radius control

F

IBER

-D

UCT

Accessories

TRC2BL

TRC4BL

FITF2X2

NR2
NR4

F14PWN-L

F14PN-L

FBB

FITF4X4A

FITF4X4B

Part Number

Part Description

System Size

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

TRC2BL

Bend radius control trumpet for exiting at the sidewall
of 50.8mm wall heights of Type G or Type FS Wiring
Duct channels

2x2

1

10

TRC4BL

Bend radius control trumpet for exiting at the sidewall
of 100mm wall heights of Type G or Type FS Wiring
Duct channels

4x4

1

10

Part Number

Part Description

System Size

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Innerduct Transition Fitting - 2x2 Size

Provides transition from 2x2 

F

IBER

-D

UCT

Routing

System to 19mm or 25.4mm inner duct.

2x2

1

10

Innerduct Transition Fitting - 4x4 Size

Provides transition from 4x4 

F

IBER

-D

UCT

Routing

System to two pieces of 25.4mm inner duct.

4x4

1

10

Innerduct Transition Fitting - 4x4 Size

B

Provides transition from 4x4 

F

IBER

-D

UCT

Routing

System to two pieces of 31.8mm inner duct.

4x4

1

10

Snap Rivets

L

Snap rivet fastens channel and fittings together for
added strength and rigidity. Snap rivet mounts flush
to surfaces.

2x2

50

500

BL L

4x4

50

500

Plastic Bolts and Nuts

L

6.35mm plastic bolts and wing nuts fastens channel
and fittings together for added strength and rigidity.

2x2
4x4

50

500

L

6.35mm plastic bolts and hex nuts fastens channel
and fittings together for added strength and rigidity.

2x2
4x4

50

500

Snap Bracket Clip

BB

Snap bracket enables the 

F

IBER

-D

UCT

channel to

be quickly and securely mounted. Contains all
hardware for assembly to any 

F

IBER

-D

UCT

bracket.

2x2

10

100

BB

4x4

10

100

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

2 0

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

F

IBER

-D

UCT

Mounting Brackets

FTRBE12/FTRBE12M

FTRBE58

FTRBN12/FTRBN12M

FTRBN58

FUSB

FLB12X15
FLB58X15
FLB12X20
FLB58X20

FLRB

FLB

FTRB12
FTRB58

FZBA1.5X4

Part Number

Part Description

For Threaded 

Rod Size

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Existing Threaded Rod Bracket for F

IBER

-D

UCT

System

B

Used for supporting the 2x2 and 4x4 

F

IBER

-D

UCT

Systems from existing threaded rod installations.
Bracket is secured to threaded rod with two split
nuts. Contains hardware for attaching to threaded
rods and hardware for mounting channel to bracket.

1/2”

1

10

B

5/8”

1

10

B

12mm

1

10

New Threaded Rod Bracket for F

IBER

-D

UCT

System

B

Used for supporting the 2x2 and 4x4 

F

IBER

-D

UCT

Systems from new threaded rod installations.
Bracket is secured to threaded rod with two nuts.
Contains hardware for attaching to threaded rods
and hardware for mounting channel to bracket.

1/2”

1

10

B

5/8”

1

10

B

12mm

1

10

Under-Floor Pedestal for F

IBER

-D

UCT

System

B

Used to support the 2x2 and 4x4 

F

IBER

-D

UCT

Systems by attaching to under floor pedestal (not
included). Use on pedestals up to 25.4mm in
diameter. Bracket contains hardware to attach to
pedestal and hardware for mounting channel 
to bracket.

1

10

Bracket for Attaching Threaded Rod to 38.1mm Ladder Rack

LB

Bracket attaches to 9.5mm x 38.1mm ladder rack
rail. Bracket accepts threaded rod (not included).
Contains bracket and hardware for attaching
bracket to ladder rack.

1/2”

1

10

LB

5/8”

1

10

Bracket for Attaching Threaded Rod to 50.8mm Ladder Rack

LB

Bracket attaches to 9.5mm wide x 50.8mm ladder
rack rail. Bracket accepts threaded rod (not
included). Contains bracket and hardware for
attaching bracket to ladder rack.

1/2”

1

10

LB

5/8”

1

10

Ladder Rack Bracket for F

IBER

-D

UCT

System

L B

Used to support the 2x2 and 4x4 

F

IBER

-D

UCT

Systems attaching directly to any 9.5mm x 38.1mm
or 9.5mm x 50.8mm ladder rack rail. No threaded
rod required. Contains hardware for mounting
channel to bracket.

1

10

"L" Wall Mount Bracket for F

IBER

-D

UCT

System

LB

Used to support 2x2 and 4x4 

F

IBER

-D

UCT

Systems

by attaching to a wall or the front or back of an
equipment rack. Contains hardware for mounting
channel to bracket.

1

10

Strut Metal Framing Bracket

B

Bracket attaches to strut metal framing. Contains
bracket and hardware for attaching threaded rod to
metal framing.

1/2”

1

10

B

5/8”

1

10

Adjustable "Z" Bracket

B

Bracket used to offset 

F

IBER

-D

UCT

System from

mounting surface, adjustable from 38.1mm to
101mm. Typically used on the front of an 
equipment rack.

1

10

Panduit-Pannet-html.html
background image

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.

For Threaded 

Rod Size

Part Description

Part Number

2

F

IBER

-D

UCT

Mounting Brackets (continued)

FMRB

FEIAB58

F2PCLB12
F2PCLB58

F2PCLB12M
F2PCLB58M

FRSLNKT12
FRSLNKT58

FRSLNKT12M
FRSLNKT58M

Top Rail of Rack Support Bracket

B

Bracket attaches to top rail of equipment rack for
added support in a vertical direction. Contains
hardware for attaching bracket to an EIA/TIA rack
and for mounting channel to bracket.

1

10

EIA/TIA Threaded Rod Mounting Bracket

B

Bracket consists of two identical components that
clamp onto the crossmembers of standard EIA/TIA
racks and are secured with standard hex nuts and
split lockwashers (included) tightened onto a length
of 15.9mm diameter threaded rod (not included).
The threaded rod is positioned in the centre of the
brackets providing a vertical threaded rod stud to
mount

F

IBER

R

UNNER

and

F

IBER

-D

UCT

threaded

rod mounting brackets onto.

5/8”

1

10

Two Piece Ladder Rack Bracket for Attaching Threaded Rod to 38.1mm - 50.8mm
Ladder Rack

LB

Two piece bracket attaches to 9.5mm wide x
38.1mm or 9.5mm wide by 50.8mm ladder rack rail.
Bracket halves slide into position and clamp
together on the ladder rack rail, which allows for a
one-handed assembly of the threaded rod (not
included). Contains bracket and hardware for
attaching bracket to ladder rack.

1/2”

1

10

LB

5/8”

1

10

LB

12 mm

1

10

LB

16 mm

1

10

Split Locking Nut Kit

L

Used to secure 

F

IBER

R

UNNER

mounting brackets

anywhere along pre-installed threaded rod. Split
nuts are opened, placed in desired position, closed
and tightened.

1/2”

1

10

L

5/8”

1

10

L

12 mm

1

10

L

16 mm

1

10

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

2 2

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

ANDUCT

Type H - Hinged Cover Slotted Wall Wiring Duct

Specifications

• Made of rigid PVC
• UL Recognised continuous use temperature: 50C°
• UL94 flammability rating of V-0
• Provided with mounting holes

Features & Benefits

• Integrated hinged cover design allows easy access to

wiring without hassle of removing and reinstalling cover

• Dual-sided hinge can open up to 100 from either sidewall

of duct base for easy access to channel

• Cover retention flanges prevent cover from sliding when

installed on duct base

• Double scoreline saves installation time and lowers

installed cost

• Restricted slot design retains wire in slot for fast, easy wire

installation or removal

For other colours replace BL (Black) with LG (Light Grey).
Order length required or Standard Carton Quantity.

P

ANDUCT

Type FL - Flexible Wiring Duct

Specifications

• Low smoke, halogen free, polypropylene material
• UL94 flammability rating of V-2
• UL Recognised continuous use temperature: 90C°
• Factory applied adhesive tape provided for easy mounting

Features & Benefits

• The flexibility of Type FL duct allows it to be used in 

applications where conventional rigid PVC duct cannot

• One piece design with enclosing fingers simplifies insertion

and removal of wiring

Available in GR (RAL 7032 Grey/Green) only.

Part Number

Duct Size (W x H) 

Cover Part Number

Length

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

H2X2BL6

55.1 x 50.3

HC2BL6

1800mm

6

120

H4X4BL6

108.0 x 104.1

HC4BL6

1800mm

6

60

Part Number

Duct Sixe (WXH)

Length

Std.

Pkg.

Qty.

mm

mm

FL12X12GR-A

12.5 x 12.5

500

112

FL25X25GR-A

25.0 x 25.0

500

70

FL50X50GR-A

50.0 x 50.0

500

32

Panduit-Pannet-html.html
background image

2 3

P

ANDUCT

Type G - Slotted Wall Wiring Duct 

Specifications

• Made of rigid PVC
• Rated for continuous use temperatures up to 50C°
• UL Flammability Rating: 94V-0
• Provided with mounting holes

Features & Benefits

• Wide finger design provides greater rigidity and larger 

slot width

PANDUIT

exclusive rounded edges will not cut or abrade

wiring insulation

• Non-slip cover will not slip when installed on duct base
• Flush cover design holds more wires than traditional 

duct designs

• Double scoreline saves installation time and lowers

installed cost

• Specially formulated lead free material eliminates health

concerns associated with PVC that contains lead

• Restricted slot design retains wire in slot for fast, easy wire

installation or removal

Colour Shown LG (Light Grey). Selected sizes also available in WH (White) and BL (Black).
Order number of feet required, in multiples of 1800mm or Standard Carton Quantity.

Part Number

Duct Size W x H

Slot Width

Cover Part

Number

Length

mm

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

G.5X.5LG6

17.5 x 15.2

5.1

C.5LG6

1800mm

6

120

G.5X1LG6

17.5 x 26.9

5.1

C.5LG6

1800mm

6

120

G.5X4LG6

17.5 x 104.1

7.9

C.5LG6

1800mm

6

60

G.75X.75LG6

23.6 x 20.8

7.9

C.75LG6

1800mm

6

120

G.75X1LG6

23.6 x 26.9

7.9

C.75LG6

1800mm

6

120

G.75X1.5LG6

23.6 x 39.9

7.9

C.75LG6

1800mm

6

120

G.75X2LG6

23.6 x 51.6

7.9

C.75LG6

1800mm

6

120

G1X1LG6

32.0 x 28.4

7.9

C1LG6

1800mm

6

120

G1X1.5LG6

32.0 x 41.1

7.9

C1LG6

1800mm

6

120

G1X2LG6

32.0 x 53.8

7.9

C1LG6

1800mm

6

120

G1X3LG6

32.0 x 79.2

7.9

C1LG6

1800mm

6

120

G1X4LG6

32.0 x 104.1

7.9

C1LG6

1800mm

6

60

G1.5X1LG6

44.5 x 28.4

7.9

C1.5LG6

1800mm

6

120

G1.5X1.5LG6

44.5 x 41.1

7.9

C1.5LG6

1800mm

6

120

G1.5X2LG6

44.5 x 53.8

7.9

C1.5LG6

1800mm

6

120

G1.5X3LG6

44.5 x 79.2

7.9

C1.5LG6

1800mm

6

120

G1.5X4LG6

44.5 x 104.1

7.9

C1.5LG6

1800mm

6

60

G2X1LG6

57.2 x 28.4

7.9

C2LG6

1800mm

6

120

G2X1.5LG6

57.2 x 41.1

7.9

C2LG6

1800mm

6

120

G2X2LG6

57.2 x 53.8

7.9

C2LG6

1800mm

6

120

G2X3LG6

57.2 x 79.2

7.9

C2LG6

1800mm

6

60

G2X4LG6

57.2 x 104.1

7.9

C2LG6

1800mm

6

60

G2X5LG6

57.2 x 129.5

9.5

C2LG6

1800mm

6

60

G2.5X3LG6

69.9 x 79.2

7.9

C2.5LG6

1800mm

6

120

G3X1LG6

82.6 x 28.4

7.9

C3LG6

1800mm

6

120

G3X2LG6

82.6 x 53.8

7.9

C3LG6

1800mm

6

120

G3X3LG6

82.6 x 79.2

7.9

C3LG6

1800mm

6

60

G3X4LG6

82.6 x 104.1

7.9

C3LG6

1800mm

6

60

G3X5LG6

82.6 x 129.5

9.5

C3LG6

1800mm

6

60

G4X1.5LG6

108.0 x 41.1

7.9

C4LG6

1800mm

6

120

G4X2LG6

108.0 x 53.8

7.9

C4LG6

1800mm

6

60

G4X3LG6

108.0 x 79.2

7.9

C4LG6

1800mm

6

60

G4X4LG6

108.0 x 104.1

7.9

C4LG6

1800mm

6

60

G4X5LG6

108.0 x 129.5

9.5

C4LG6

1800mm

6

60

G6X4LG6

158.8 x 105.4

7.9

C6LG6

1800mm

6

60

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

2

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

ANDUCT

Type F - Slotted Wall Wiring Duct 

Specifications

• Made of rigid PVC
• UL Recognised continuous use temperature: 50C°
• UL94 flammability rating of V-0
• Provided with mounting holes

Features & Benefits

• Narrow finger design provides closer spacing for use with

higher density applications

PANDUIT

exclusive rounded edges will not cut hands or

abrade wiring insulation

• Non-slip cover will not slide easily when installed on 

duct base

• Flush cover design holds more wires than traditional 

duct designs

• Double scoreline saves installation time and lowers

installed cost

• Specially formulated lead free material eliminates health

concerns associated with PVC that contains lead

• Restricted slot design retains wire in slot for fast, easy wire

installation or removal

For other colours replace LG (Light Grey) with WH (White).
Order length required, in multiples of 1800mm or Standard Carton Quantity.

Part Number

Duct Size W x H

Slot Width

Cover Part

Number

Length

mm

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

F.5X.5LG6

17.5 x 15.2

5.1

C.5LG6

1800mm

6

120

F.5X1LG6

17.5 x 26.9

5.0

C.5LG6

1800mm

6

120

F.75X.75LG6

23.6 x 20.8

5.0

C.75LG6

1800mm

6

120

F.75X1.5LG6

23.6 x 39.9

5.0

C.75LG6

1800mm

6

120

F1X1LG6

32.0 x 28.4

5.0

C1LG6

1800mm

6

120

F1X1.5LG6

32.0 x 41.1

5.0

C1LG6

1800mm

6

120

F1X2LG6

32.0 x 53.8

5.0

C1LG6

1800mm

6

120

F1X3LG6

32.0 x 79.2

5.0

C1LG6

1800mm

6

120

F1X4LG6

32.0 x 104.1

5.0

C1LG6

1800mm

6

60

F1.5X1LG6

44.5 x 28.4

5.0

C1.5LG6

1800mm

6

120

F1.5X1.5LG6

44.5 x 41.1

5.0

C1.5LG6

1800mm

6

120

F1.5X2LG6

44.5 x 53.8

5.0

C1.5LG6

1800mm

6

120

F1.5X3LG6

44.5 x 79.2

5.0

C1.5LG6

1800mm

6

120

F1.5X4LG6

44.5 x 104.1

5.0

C1.5LG6

1800mm

6

60

F2X1LG6

57.2 x 28.4

5.0

C2LG6

1800mm

6

120

F2X1.5LG6

57.2 x 41.1

5.0

C2LG6

1800mm

6

120

F2X2LG6

57.2 x 53.8

5.0

C2LG6

1800mm

6

120

F2X3LG6

57.2 x 79.2

5.0

C2LG6

1800mm

6

60

F2X4LG6

57.2 x 104.1

5.0

C2LG6

1800mm

6

60

F2X5LG6

57.2 x 129.5

5.0

C2LG6

1800mm

6

60

F3X1LG6

82.6 x 28.4

5.0

C3LG6

1800mm

6

120

F3X2LG6

82.6 x 53.8

5.0

C3LG6

1800mm

6

120

F3X3LG6

82.6 x 79.2

5.0

C3LG6

1800mm

6

60

F3X4LG6

82.6 x 104.1

5.0

C3LG6

1800mm

6

60

F3X5LG6

82.6 x 129.5

5.0

C3LG6

1800mm

6

60

F4X2LG6

108.0 x 53.8

5.0

C4LG6

1800mm

6

60

F4X3LG6

108.0 x 79.2

5.0

C4LG6

1800mm

6

60

F4X4LG6

108.0 x 104.1

5.0

C4LG6

1800mm

6

60

F4X5LG6

108.0 x 129.5

5.0

C4LG6

1800mm

6

60

Panduit-Pannet-html.html
background image

2

P

ANDUCT

Type G Duct Wire Retainer

P

ANDUCT

Type F Duct Wire Retainers/Labelling Device

• For use with Type F Duct to contain wiring when cover 

is removed

• Can also be used as a labelling device

• FWR-C works with all Type F Duct sizes

Full length for use with 100mm wide duct. For smaller widths, break off segments at scorelines.

Part Number

Material

For Duct Width

For Duct Height

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

WR2-C

ABS

50.8

50.8 - 101.6

100

1000

WR3-C

ABS

76.2

50.8 - 101.6

100

1000

WR4-C

ABS

101.6

50.8 - 101.6

100

1000

WR5-C

ABS

Use with: 3X5, 4X5 or 6X4

Type G Duct

Use with: 3X5, 4X5 or 6X4

Type G Duct

100

1000

Part Number

Material

For Duct Width

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

FWR-C

RIGID PVC

37.0 - 76.2

100

1000

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

• Snaps into slots of Type G Duct to contain wiring whencover is removed

Panduit-Pannet-html.html
background image

2

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

ANDUCT

Type FS - Solid Wall Raceway 

Specifications

• Made of rigid PVC
• UL Recognised continuous use temperature: 50C°
• UL94 flammability rating of V-0
• Supplied without mounting holes

Features & Benefits

• Non-slip cover will not slide easily when installed on 

duct base

• Flush cover design holds more wires than traditional 

duct designs

• Base scoreline allows full wire carrying capacity at wiring

duct junctions such as “T”s and corners

• Specially formulated lead free material eliminates health

concerns associated with PVC which contains lead

Colour Shown LG (Light Grey). Selected sizes also available in WH (White) and BL (Black).
Order length required or Standard Carton Quantity.

Part Number

Duct Size W x H

Cover Part Number

Length

mm

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

FS.5X.5LG6NM

17.5 x 15.2

C.5LG6

1800mm

6

120

FS.5X1LG6NM

17.5 x 26.9

C.5LG6

1800mm

6

120

FS.75X.75LG6NM

23.6 x 20.8

C.75LG6

1800mm

6

120

FS1X1LG6NM

32.0 x 28.4

C1LG6

1800mm

6

120

FS1X1.5LG6NM

32.0 x 41.1

C1LG6

1800mm

6

120

FS1X2LG6NM

32.0 x 53.8

C1LG6

1800mm

6

120

FS1X3LG6NM

32.0 x 79.2

C1LG6

1800mm

6

120

FS1.5X1LG6NM

44.5 x 28.4

C1.5LG6

1800mm

6

120

FS1.5X1.5LG6NM

44.5 x 41.1

C1.5LG6

1800mm

6

120

FS1.5X2LG6NM

44.5 x 53.8

C1.5LG6

1800mm

6

120

FS1.5X3LG6NM

44.5 x 79.2

C1.5LG6

1800mm

6

120

FS2X1LG6NM

57.2 x 28.4

C2LG6

1800mm

6

120

FS2X1.5LG6NM

57.2 x 41.1

C2LG6

1800mm

6

120

FS2X2LG6NM

57.2 x 53.8

C2LG6

1800mm

6

120

FS2X3LG6NM

57.2 x 79.2

C2LG6

1800mm

6

60

FS3X1LG6NM

82.6 x 28.4

C3LG6

1800mm

6

120

FS3X2LG6NM

82.6 x 53.8

C3LG6

1800mm

6

120

FS3X3LG6NM

82.6 x 79.2

C3LG6

1800mm

6

60

FS3X4LG6NM

82.6 x 104.1

C3LG6

1800mm

6

60

FS3X5LG6NM

82.6 x 129.5

C3LG6

1800mm

6

60

FS4X2LG6NM

108.0 x 53.8

C4LG6

1800mm

6

60

FS4X3LG6NM

108.0 x 79.2

C4LG6

1800mm

6

60

FS4X4LG6NM

108.0 x 104.1

C4LG6

1800mm

6

60

FS4X5LG6NM

108.0 x 129.5

C4LG6

1800mm

6

60

FS6X4LG6NM

158.8 x 105.4

C6LG6

1800mm

6

60

Panduit-Pannet-html.html
background image

2

P

ANDUCT

Type NNC - Halogen Free Metric Wiring Duct

Specifications

• Made of halogen free material
• UL Recognised continuous use temperature: 65C°
• Heat deflection temperature 264 psi of 102C°

per ASTM D 648

• UL94 flammability rating of V-0
• Provided with mounting holes

Features & Benefits

• Halogen free material eliminates safety and environmental

concerns associated with halogenated materials

• Suitable for applications in elevated 

temperature environments

PANDUIT

exclusive rounded edges will not cut hands or

adbrade wiring insultation

• Non-slip cover will not slide easily when installed on 

duct base

• Double scoreline saves installation time and lowers

installed cost

• Restricted slot design retains wire in slot for fast, easy wire

installation or removal

Available in LG (Light Grey) only.
DO NOT allow cutting, tapping or cleaning fluids that contain hydrocarbons to come in contact with Type NNC
Wiring Duct.
Order by total number of metres required, in Standard Carton Quantity

Part Number

Duct Size W x H

Length

Std. Ctn.

Qty.

mm

M

M

NNC25X50LG2

24.6 x 47.8

2

20

NNC37X37LG2

37.1 x 35.8

2

20

NNC37X50LG2

37.1 x 47.8

2

20

NNC37X75LG2

37.1 x 72.4

2

20

NNC50X50LG2

49.5 x 47.8

2

20

NNC50X75LG2

49.5 x 72.4

2

10

NNC75X75LG2

74.7 x 72.4

2

10

NNC100X50LG2

99.6 x 47.8

2

10

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

2 8

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

ANDUCT

Installation Tools

• DCT easily cuts any 

P

ANDUCT

duct & cover

• DNT-100 notches sidewalls to bottom scoreline for tees 

and corner junctions

• TNR installs and removes 

P

ANDUCT

Nylon Rivets (NR1)

quickly and easily

• DFCT easily removes duct fingers in tight places

DCT

Always use approved safety goggles when using any tools.

P

ANDUCT

Accessories - Divider Wall

• Wiring duct divider wall can be mounted inside any type of

P

ANDUCT

PVC wiring duct to create multiple channels

• Simply install the divider wall base when mounting the 

duct and snap the divider wall onto the mounting base
accessory (shown below)

• Both versions snap onto DB-C mounting base
• Divider wall heights 50mm and greater have a scoreline

feature allowing sections to be removed leaving a 
smooth edge

NOTE: Use of 4 mounting bases per every 1800mm of divider wall is recommeded,
For ordering divider wall, order total length required in standard lengths or Standard Package Quantity.

DNT-100

TNR

NR1-C

DFCT

D1H6   D1.5H6   

D2H6   D3H6   D4H6

SD2H6   SD3H6   SD4H6

DB-C

Part Number

Used with Anchors

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Panduct Divider Wall Mounting Base

DB-C

PANDUIT

NR1 or #8 or #10 screw

100

1000

Part Number

Part Description

Std.

Pkg.

Qty.

P

ANDUCT

Duct Cutting Tool (For use with all duct/raceway types)

DCT

Hand held duct cutting tool.

1

Replacement Blade Kit (Includes Blade and Nylon Insert)

DCT-BLD

Replacement blade and nylon insert.

1

Replacement Nylon Insert

DCT-RI

Replacement nylon insert.

5

P

ANDUCT

Duct Cutting Tool (For use with all duct/raceway types)

DNT-100

Hand held sidewall notching tool.

1

P

ANDUCT

Nylon Rivet Installation Tool

TNR

Hand held nylon rivet installation tool.

1

P

ANDUCT

Nylon Rivets

NR1-C

Nylon rivet for use with TNR rivet tool.

100

P

ANDUCT

Duct Finger Cutting Tool (For use with type G, F, and PE duct)

DFCT

Hand held duct finger cutting tool.

1

Part Number

For Nominal Duct Height

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

Divider Wall For use with Type AC, BC, & ASC Panel Trunking

D1H6

25

6

120

D1.5H6

37

6

120

D2H6

50

6

120

D3H6

75

6

120

D4H6

100

6

120

Panduct Slotted Divider Wall

SD2H6

50

6

120

SD3H6

75

6

120

SD4H6

100

6

120

Panduit-Pannet-html.html
background image

2 9

P

ANDUCT

Duct Corner Strip with 25mm Bend Radius Control

• Creates a strong rigid corner at wiring duct junctions
• 25mm bend radius on inside corner protects sensitive 

data cabling

• Available in five pre-cut sizes and 1800mm lengths that can

be cut-to-size to meet any size requirement

• Easy to install two piece design
• Compatible with all styles of 

PANDUIT

Wiring Duct

For other colours replace LG (Light Grey) with BL (Black) or WH (White).
CSPC available in LG (Light Grey) only.
Order number of metres required, or Standard Package Quantity.

Bend Radius Control Trumpet

• Available for 50.8mm and 101.60mm wall height Type G

Slotted Wall Wiring Duct and Type FS Solid Wall Raceway

• New style TRC2HDBL is available for 50.8mm wall height

Type H Hinged Cover Wiring Duct

• Provides method to transition cabling from wall mounted

hardware to wiring duct channel

• Maintains complete 25.4mm bend radius control

Available in BL (Black) only

TRC4BL

TRC2HDBL

TRC2BL

Part Number

Part Description

Material

For Duct

Height

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

1800mm lengths for use with all Types of PVC Wiring Duct

CSC1LG6

Cut-to-size 1800mm corner strip with
a 25mm bend radius.

PVC

All sizes (Cut

to duct height)

6

120

Pre-cut Pieces for use with all Types of PVC Wiring Duct

CSPC1LG-Q

25mm bend radius corner strip 
pre-cut for 25.4mm wall height

PVC

25.4

25

250

CSPC1.5LG-Q

25mm bend radius corner strip 
pre-cut for 38.1mm wall height

PVC

38.1

25

250

CSPC2LG-Q

25mm bend radius corner strip 
pre-cut for 50.8mm wall height

PVC

50.8

25

250

CSPC3LG-Q

25mm bend radius corner strip 
pre-cut for 76.2mm wall height

PVC

76.2

25

250

CSPC4LG-Q

25mm bend radius corner strip 
pre-cut for 101.6mm wall height

PVC

101.6

25

250

Part Number

Part Description

Material

For Duct

Height

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

TRC2BL

Bend radius control trumpet for exiting at the
sidewall of 50.8mm wall heights of Type G or
Type FS Wiring Duct channels

ABS

50.8

1

10

TRC4BL

Bend radius control trumpet for exiting at the
sidewall of 101.6mm wall heights of Type G or
Type FS Wiring Duct channels

ABS

101.6

1

10

TRC2HDBL

Bend radius control trumpet for exiting at the
sidewall of 50.8mm wall heights of Type H
Hinged Cover Wiring Duct channels. Black
colour only.

ABS

50.8

1

10

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

2 0

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Notes

Panduit-Pannet-html.html
background image

251

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

N

ON

-M

ETALLIC

S

URFACE

R

ACEWAY

P

AN

-W

AY

Non-Metallic Surface Raceways provide maximum flexibility for routing, protecting,

concealing and terminating high performance copper, voice, video, fibre optic and power cabling.

PANDUIT

surface raceways are designed with attention to function and aesthetics to blend with

any décor.

PANDUIT

surface raceway systems include transition fittings that facilitate seamless

integration of one 

PANDUIT

surface raceway system to another.

PANDUIT

Surface Raceway

Systems work with all 

PANDUIT M

INI

-C

OM

Modules for complete connectivity possibilites.

Aesthetically pleasing

Lightweight

Tamper resistant

Bend radius control

Resists dents and conceals scratches and chips

Ease of modifications and additions

Lowest installed cost

PANDUIT

surface raceway provides a variety of choices when selecting data and electrical

terminations. All 

PANDUIT

surface raceways include a full complement of fittings that are

designed to maintain the proper bend radius control required for high performance copper and

fibre optic cabling systems. All of the raceways accept either NEMA 70mm standard screw-on

faceplates or superior 

P

AN

-W

AY

Snap-on Faceplates.

PANDUIT

surface raceway systems work

with all 

PANDUIT M

INI

-C

OM

Modules, for complete connectivity possibilities.

Panduit-Pannet-html.html
background image

252

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

-W

AY

O

FFICE

F

URNITURE

R

ACEWAY

P

AN

-W

AY

Office Furniture Raceway is a one-piece single channel system designed to route data

cabling along the top of office furniture partitions. Outlets can be positioned at any point along

the partition at desk level or in the corner at the intersection of two partitions. Office Furniture

Raceway has a tamper resistant closure design, which protects sensitive cabling from accidental

damage and discourages unauthorised access, yet the system is accessible by a qualified installer

for moves, adds and changes.

Designed for desktop terminations which utilise
the typically unused area of the cubicle

Fittings meet TIA/EIA bend radius requirements
preventing cable performance degradation, yet
maintain original aesthetic "squared corner"
styling of furniture

Designed to work with major office furniture
manufacturers panels (such as Steelcase, Herman
Miller and others) 

Robust design includes a one-piece hinge and
tamper resistant closure design which increases
product stability and reduces inadvertent or
unauthorised access to data cabling

Designed for use with 

PANDUIT

connectivity; also

accepts common manufacturers’ connectivity with
use of a NEMA standard 70mm faceplate or
module frame

The system includes a full complement of fittings, accessories, and termination options.

P

AN

-W

AY

Office Furniture Raceway is available in four popular colours to blend with most office

furniture systems and creates a virtually invisible cost effective routing solution.

Panduit-Pannet-html.html
background image

253

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Office Furniture Raceway Roadmap

C

T

M

P

See exploded
view 2

J

K

V

S

N

D

1

L

O

R

Q

F

A

B

E

H

See exploded
view 1

U

G

NOTE: Office Furniture Raceway is designed to blend with its environment. Shown in White on Office Grey Slate furniture for illustration purposes only.

Panduit-Pannet-html.html
background image

254

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

O

V

U

T

S

R

Q

P

N

M

L

B

C

D

E

F

G

H

J

K

A

1

OFR20**6 — Office Furniture Raceway  

OFVR5**6 — Vertical Raceway

OFR20CP**8 — Communication Pole 

OFR20OFCR70**4 — Four Cubicle
Drop Fitting

OFR20OFCR70**2 — Two Cubicle
Drop Fitting

OFCR70EC** — End Cap Fitting

OFR20SO** — Spill Over Fitting

OFR20DMB** — Desk Mount Box 

OFR20MPT** — Mid Panel Tee Fitting 

OFR20T** — Tee Fitting

OFR20CR** — Cross Fitting

OFR20IC**  — Inside Corner Fitting 

OFR20OC** — Outside Corner Fitting 

OFR20CC** — Coupler Fitting 

OFR20EC** — End Cap Fitting 

OFR20OFCR70**1 — One Cubicle
Drop Fitting

OF70FV4** — Vertical Sloped
Communication Snap-on Faceplate 

OFR20WE** — Wall Entrance Fitting 

OF70FH4** — Horizontal Sloped
Communication Snap-on Faceplate 

OFCR70**6 — Corner Raceway Base 

OFCRC70**6 — Corner Raceway Cover 

OFR20RA** — Right Angle Fitting

Panduit-Pannet-html.html
background image

255

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

A.

OFR20OFCR70**4 = Four Cubicle Drop Fitting.

B.

OFCR70**6 = Corner Raceway Base.

C.

OFCR70EC = End Cap Fitting.

D.

OF70FV4 = Vertical Sloped Communication 
Snap-on Faceplate.

E.

M

INI

-C

OM

Modules.

F.

OFCRC70**6 = Corner Raceway Cover.

Components Required

See page

Office Furniture Configurations

Exploded view 1

258

257

258 

259 

19 - 30

257

A

B

C

D

E

F

Panduit-Pannet-html.html
background image

256

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

A.

OFR20SO** = Spill Over Fitting.

B.

OFVR5**6 = Vertical Raceway.

C.

OFR20DMB = Desk Mount Box.

D.

M

INI

-C

OM

Modules.

E.

OF70FH4** = Horizontal Sloped Communication
Snap-on Faceplate.

Components Required

See page

Office Furniture Configurations (continued)

Exploded view 2

258 

257 

258 

19-30 

259 

A

B

C

D

E

Panduit-Pannet-html.html
background image

257

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

Office Furniture Raceway System

• UL listed in accordance with UL-5C requirements for Class

2 Communication Cable Management Systems

• Maintains bend radius control throughout the entire Office

Furniture Raceway system as required by TIA/EIA-568-B
and 569-B

• Faceplates are compliant with the labelling requirements of

the TIA/EIA-606-A standard 

• Robust design and tamper resistant closure increases

product stability and prevents damage to cabling during
and after installation

• Product supplied with adhesive backing for fast and easy

installation

• Creates a virtually invisible solution for routing data cables

on panels from all common manufacturers with a top cap
width between 47.75mm and 58.42mm

• Designed for use with 

P

AN

-N

ET

Connectivity, also accepts

all common manufacturers’ connectivity with use of a
NEMA standard 70mm faceplate or module frame

OFR20

Office Beige (OB)

‡ For other colours, replace OB (Office Beige) with OS (Office Slate), OG (Office Grey) or MT (Medium Tone).
Order number of feet required in multiples of standard carton quantity.

P

AN

-W

AY

Office Furniture Raceway Fittings 

• Office Furniture Raceway fittings have been designed to maintain the TIA/EIA required 25.4mm minimum bend radius for

high performance copper and fibre optic cabling systems

47.7mm

43.4mm

OFFICE FURNITURE RACEWAY

Internal Area = 1490.31mm

2

Office Slate (OG)

Office Grey (OS)

Medium Tone (MT)

OFCR70

OFCRC70

OFR20CP

OFVR5

Part Number

Part Description

Raceway 

Size

Colour

Length

(ft)

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

OFR20OB6

Office Furniture Raceway. One
piece single channel low voltage
raceway with adhesive tape backing
for data cable routing along top of
modular furniture partitions. Available
in 1800mm lengths.

47.7mm x
43.4mmm

Office
Beige

1800 6

48

‡ For other colours, replace OB (Office Beige) with OS (Office Slate), OG (Office Grey) or MT (Medium Tone).
** Computer printable labels found on pages 349 - 356.

Part Number

Part Description

Labels

Required

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

OFCR70OB6

Office Furniture Corner Raceway Base. Used to
terminate low voltage data cabling in the corner
at the intersection of modular office furniture
panels. Accepts 70mm standard faceplates.
Available in 1800mm lengths.

Office
Beige

6

48

OFCRC70OB6

Office Furniture Corner Raceway Cover.
Available in 1800mm lengths.

Office
Beige

6

48

OFVR5OB6

Office Furniture Vertical Raceway. One piece
single channel raceway used to connect
OFR20**6 to desk mount box (OFR20DMB**)
and must be used with OFR20SO** or
OFR20DSO**. Available in 1800mm lengths.

Office
Beige

6

120

OFR20CPOB8

Communication Pole. Allows for data cable entry
into Office Furniture Raceway from suspended
ceiling. 2438.4mm pole allows maximum
2133.6mm distance from top of furniture
partition to ceiling. Must be used with
OFR20MPT**. NOTE: Not intended for use at
intersection of furniture panels.

Office
Beige

1

0

Panduit-Pannet-html.html
background image

258

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

-W

AY

Office Furniture Raceway Fittings (continued)

OFR20OFCR70**4

OFR20OFCR70**2

OFR20OFCR70**1

OFRCR70EC

OFR20SO

OFR20DSO

OFR20DMB

OFR20MPT

‡ For other colours, replace OB (Office Beige) with OS (Office Slate), OG (Office Grey) or MT (Medium Tone).
** Computer printable labels found on pages 349 - 356.

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.

Colour

Labels

Required

Part Description

Part Number

OFR20OFCR70OB4

Four Cubicle Drop Fitting. Allows the transition
from Office Furniture Raceway run horizontally
along partition wall to Office Furniture Corner
Raceway mounted vertically in four cubicles at
the intersection of partitions. Fitting maintains
25.4mm minimum bend radius of cabling.
Supplied with adhesive tape.

Office
Beige

1

10

OFR20OFCR70OB2

Two Cubicle Drop Fitting. Allows the transition
from Office Furniture Raceway run horizontally
along partition wall to Office Furniture Corner
Raceway mounted vertically in two cubicles at
the intersection of partitions. Fitting maintains
25.4mm minimum bend radius of cabling.
Supplied with adhesive tape.

Office
Beige

1

10

OFR20OFCR70OB1

One Cubicle Drop Fitting. Allows the transition
from Office Furniture Raceway run horizontally
along partition wall to Office Furniture Corner
Raceway mounted vertically in one cubicle at
the intersection of partitions. Fitting maintains
25.4mm minimum bend radius of cabling.
Supplied with adhesive tape.

Office
Beige

1

10

OFCR70ECOB

Corner Raceway End Cap Fitting. Opening
allows cord passage through fitting such as
monitor and keyboard cables. Supplied with
adhesive tape.

Office
Beige

1

10

OFR20SOOB

Spill-over Fitting. Allows transition from Office
Furniture Raceway run horizontally along
partition wall to Office Furniture Vertical
Raceway in one location. Adjustable fitting
maintains 25.4mm minimum bend radius of
cabling and works with various panel widths
between 47.7mm - 58.42mm. Supplied with
adhesive tape.

Office
Beige

1

10

OFR20DSOOB

Double Spill-Over Fitting. Fitting is used to spill
over both sides of the furniture partitions at the
same location. Incorporates a built-in, yet
removable end cap that eliminates the need
for additional raceway and fittings to terminate
the pathway.

Office
Beige

1

10

OFR20DMBOB

Desk Mount Box. Box accepts Office Furniture
Snap-on Faceplates as well as 70mm NEMA
standard screw-on faceplates. Designed for use
with OFVR5**6 raceway and OFR20SO**,
OFR20DSO** spill over fittings. Supplied with
adhesive tape.

Office
Beige

1

10

OFR20MPTOB

Mid-panel Tee Fitting. Used to connect
communication pole to Office Furniture Raceway
run horizontally along partition wall. Supplied
with adhesive tape.
NOTE: Not intended for use at intersection of
furniture panels.

Office
Beige

1

10

Panduit-Pannet-html.html
background image

259

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

‡ For other colours, replace OB (Office Beige) with OS (Office Slate), OG (Office Grey) or MT (Medium Tone).
** Computer printable labels found on pages 349 - 356.

P

AN

-W

AY

Office Furniture Raceway Fittings (continued)

OFR20WE

OFR20RA

OFR20T

OFR20CR

OFR20IC

OFR20OC

OFR20CC

OFR20EC

OF70FH2

OF70FV2

OF70FH4

OF70FV4

T70SDB-X

OFR20LC

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.

Colour

Labels

Required

Part Description

Part Number

OFR20WEOB

Wall Entrance Fitting. Allows entry from wall to
Office Furniture Raceway run horizontally along
partition walls. Fitting includes bend radius
protection and trim plate to cover wall opening.
Requires minimum wall opening of 114.3mmW x
76.2mmH. Supplied with adhesive tape.

Office
Beige

1

10

OFR20RAOB

Right Angle Fitting. Used to join sections of
Office Furniture Raceway at 90° flat junction.
Supplied with adhesive tape.

Office
Beige

1

10

OFR20TOB

Tee Fitting. Used to create an undivided tee
junction between sections of Office Furniture
Raceway. Supplied with adhesive tape.

Office
Beige

1

10

OFR20CROB

Cross Fitting. Used to join sections of Office
Furniture Raceway at four corners. Supplied
with adhesive tape.

Office
Beige

1

10

OFR20ICOB

Inside Corner Fitting. Used to join sections of
Office Furniture Raceway at inside corner.
Supplied with adhesive tape.

Office
Beige

1

10

OFR20OCOB

Outside Corner Fitting. Used to join sections of
Office Furniture Raceway at outside corner.
Supplied with adhesive tape.

Office
Beige

1

10

OFR20CCOB-X

Coupler Fitting. For use with Office
Furniture Raceway.

Office
Beige

10

100

OFR20LCOB

Long Coupler Fitting. Used to bridge Office
Furniture Raceway between panel sections. Can
also be used to fill void left by Spill-over Fitting,
when furniture partitions are reconfigured.

Office
Beige

1

10

OFR20ECOB

End Cap Fitting. Used to terminate Office
Furniture Raceway. Supplied with adhesive
tape.

Office
Beige

1

10

OF70FH2OB**

Snap-on Single Gang Horizontal Sloped
Communication Faceplate. Accepts up to two

M

INI

-C

OM

modules (not included). 

No additional mounting hardware required. 
TIA/EIA-606-A compliant.

1-One

Port

1-Two

Port

Office
Beige

1

10

OF70FV2OB**

Snap-on Single Gang Vertical Sloped
Communication Faceplate. Accepts up to two

M

INI

-C

OM

modules (not included). 

No additional mounting hardware required. 
TIA/EIA-606-A compliant.

1-One

Port

1-Two

Port

Office
Beige

1

10

OF70FH4OB**

Snap-on Single Gang Horizontal Sloped
Communication Faceplate. Accepts up to four

M

INI

-C

OM

modules (not included). 

No additional mounting hardware required. 
TIA/EIA-606-A compliant.

1-One

Port

1-Four

Port

Office
Beige

1

10

OF70FV4OB**

Snap-on Single Gang Vertical Sloped
Communication Faceplate. Accepts up to four

M

INI

-C

OM

modules (not included). 

No additional mounting hardware required.
TIA/EIA-606-A compliant.

1-One

Port

2-Two

Port

Office
Beige

1

10

T70SDB-X

Standard Faceplate Bracket. Used to mount
NEMA standard 70mm single gang screw-on
electrical/communication faceplates only.

Grey

10

Panduit-Pannet-html.html
background image

260

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Cable Fill Capacities for Office Furniture

This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary
according to the cable installation methods, straightness of cables, etc.

Cable fill #1:

Open Channel 

without Devices

A = 1490.32mm

2

SPEC = 40% cable fill — 

The recommended design in cable

capacity,  leaves room for future moves, adds and changes.

MAX for Data = 60% cable fill — 

The maximum cable

quantity based on cable interweaving and packing factors.

MAX for Power cable fill — 

The maximum of electrical

cables based on UL temperature rise test.

CR-SR-Cove-Wirefill1

Raceway Type & Configuration

Fill

Area

(mm

2

)

Data Grade Cable

Data Grade Cable

Audio/Video Cable

Fibre Optic Cable 

24 AWG/UTP CM

24 AWG/UTP CM

RG6

2 Strand

Cat 5e (4pr)

Cat 6 (4pr)

DIA. = 5.51mm

DIA. = 6.35mm

DIA. = 6.99mm

DIA. = 4.4mm

FILL

FILL

FILL

FILL

SPEC

MAX

SPEC

MAX

SPEC

MAX

SPEC

MAX

(40%)

(60%)

(40%)

(60%)

(40%)

(60%)

(40%)

(60%)

1.

OFR20:  No Devices.

1490.32

24

37

18

28

15

23

38

57

Panduit-Pannet-html.html
background image

261

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

C

OVE

R

ACEWAY

P

AN

-W

AY

Cove Raceway is a full line of NEC and TIA/EIA compliant raceway, which has the 

appearance of architectural moulding; that allows you to route, conceal, protect and terminate cop-

per, voice, video, fibre optic or power cabling.This offering adds elegance to any room or work area by 

softening the horizontal angles between the wall and ceiling or the vertical angles between 

two walls.

UL & CSA rated 600V

Bend radius control is maintained throughout the
entire system as required by TIA/EIA-568-B and 569-B

Product mounts high out of reach for increased
tamper resistance

Divided channel system allows for routing and
terminations of both power and data cabling

Raceway and fitting covers may be painted to match

any décor

P

AN

-W

AY

Cove Raceway includes a full complement of fittings and transitions easily to other

PANDUIT

raceway such as LD, LDP, LD2P10,T-45 and T-70.

Panduit-Pannet-html.html
background image

262

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Cove Raceway Roadmap

A

B

1

2

L

M

P

3

See exploded
view 3

See exploded
view 4

See exploded
view 2

See exploded
view 1

C

D

E

F

G

H

J

K

N

O

U

T

D

V

U

Q

R

S

4

D

K

D

Panduit-Pannet-html.html
background image

263

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

H

J

K

L

M

N

P

Q

R

S

T

U

V

O

1

1

2

3

3

4

4

A

B

C

D

E

F

G

WCM35BIW, WCM35CIW – 
Cove Raceway Base and Cover 

WCM35DW – Cove Raceway 
Divider Wall

T70DW – T-70 Raceway Divider Wall 

T70B**, T70C** – T-70 Raceway
Base and Cover

WCM35TR10IW – Cove Raceway
Low Profile Transition Fitting for
LD/LDP10 Raceway

JBP1** – Power Rated Single Gang
Two-Piece Box

CPG** – Single Gang Rectangular
Electrical/Communication 
Screw-on Faceplate

WCM35ICIW – Cove Raceway Inside
Corner Fitting

ERU20** – 20A Rectangular Outlet 

WCM35TRIW – Cove Raceway
Transition Fitting for T-45 and LD
Series Raceways

WCM35ECIW – Cove Raceway 
End Cap

LDP10** – LDP10 Raceway 

T45B**, T45C** – T-45 Raceway
Base and Cover

T45DW– T-45 Raceway Divider Wall 

JBP2FS** – 

F

AST

-S

NAP

Double

Gang Power Rated Surface Mount
Outlet Box

WCM35CCIW – Cove Raceway
Cover Coupler Fitting 

WCM35TR70IW – Cove Raceway
Low Profile Transition Fitting for 
T-70 Raceway

UIT70FH2** – 

U

LTIMATE

ID

Horizontal Snap-on Faceplate

UIT70FV4** – 

U

LTIMATE

ID

Sloped

Vertical Snap-on Faceplate 

T70EC** – T70 Raceway End Cap
Fitting

WCM35DBFIW – Cove Raceway
Device Box and Faceplate Adapter 

WCM35TI – Cove Raceway Tee
Fitting Insert

FP2RC – Double Gang Rectangular
Electrical and Communication
Faceplate

WCM35TIW – Cove Raceway Tee
Fitting

WCM35OCIW – Cove Raceway
Outside Corner Fitting

T70WC2** – T-70

W

ORKSTATION

O

UTLET

C

ENTER

Offset Box for

Snap-on Faceplates

UIT70FH4** – 

U

LTIMATE

ID

Horizontal Snap-on Faceplate 

T70PG** – Single Gang Rectangular
Electrical/Communication Snap-on
Faceplate

Panduit-Pannet-html.html
background image

264

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Cove Configurations

A.

WCM35TR10 = Cove Raceway Low Profile Transition  
Fitting for LD/LDP10 Raceway.

B.

JBP1 = Power Rated Single Gang Two-Piece Box.

C.

ERU20 = 20A Rectangular Electrical Outlet
(screws included).

D.

CPG = Screw-on Single Gang Rectangular Faceplate.

Components Required

Exploded view 1

Exploded view 2

A

C

B

A.

WCM35TR = Cove Raceway Transition Fitting.

B.

JBP2FS = 

F

AST

-S

NAP

Double Gang Power Rated 

Surface Mount Outlet Box.

C.

M

INI

-C

OM

Modules.

D.

T70PG = Single Gang Rectangular 
Electrical/Communication Snap-on Faceplate.

E.

UIT70FV4 = 

U

LTIMATE

ID

Sloped Vertical  

Snap-on Faceplate.

F.

ERU20 = 20A Rectangular Electrical Outlet 
(screws included).

Components Required

A

E

D

C

D

B

F

Panduit-Pannet-html.html
background image

265

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Cove Configurations (continued)

Exploded view 3

A.

WCM35DBF = Cove Raceway Device Box and
Faceplate Adapter.

B.

FP2RC = 

P

AN

-W

AY

Classic Series Faceplates for

Power and Communication. 

C.

M

INI

-C

OM

Modules.

D.

ERU20 = 20A Rectangular Electrical Outlet 
(screws included).

Components Required

C

Exploded view 4

A

C

A.

WCM35DBF = Cove Raceway Device Box and
Faceplate Adapter.

B.

M

INI

-C

OM

Modules.

C.

UIT70FH4 = 

U

LTIMATE

ID

Horizontal 

Snap-on Faceplate. 

Components Required

A

A

B

A

B

D

Panduit-Pannet-html.html
background image

266

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

-W

AY

Cove Raceway System

• UL & CSA rated 600V; meets UL5A and CSA C22.2 

No. 62.1-03 standards

• Bend radius control is maintained throughout the entire

Cove Raceway System as required by TIA/EIA-568-B 
and 569-B

• Tamper resistant

• Transitions to 

PANDUIT

T-70

T-45, and LD 

Profile Raceways

• Cove raceway and fittings may be painted to blend with 

any decor

• Supplied with pre-punched mounting holes

WCM35BIW8

WCM35CIW8

‡ All parts available in IW (Off White) only except for WCM35DW8 which is available in Grey only.
Order number of feet required in multiples of standard carton quantity.
Order raceway base and cover separately.

Part Number

Part Description

Raceway

Size

Colour

Length

(ft)

Std. 
Ctn. 
Qty.

Cove Raceway Base 

WCM35BIW8

Cove Raceway Base is available in 203.2mm
lengths and is used for mounting in the
horizontal corner between the ceiling and
wall or vertical corner between walls.

88.9 x

88.9mm

Off

White

8

64

Cove Raceway Cover

WCM35CIW8

Cove Raceway Cover available in 
203.2mm lengths.

Off

White

8

64

Cove Raceway Divider Wall

WCM35DW8

Cove Raceway Divider Wall. Snaps onto rails
in Cove Raceway Base to create separate
channels. Must use wire retainers to ensure
channel separation per UL/CSA. Available in
203.2mm lengths.

Grey

8

64

WCM35DW8

88.9mm

88.9mm

COVE RACEWAY

Internal Area = 4129.02mm

2

Panduit-Pannet-html.html
background image

267

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

Cove Raceway Fittings

• Cove raceway fittings are designed to maintain the TIA/EIA-568-B and 569-B required minimum bend radius for high 

performance copper and fiber optic cabling systems

‡ All parts available in IW (Off White) only except WCM35WR-X and WCM35TI which are available in Grey only.

Part Number

Part Description

Colour

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

WCM35CCIW-X

Cover Coupler Fittings. Used to join two pieces of Cove
Raceway Cover together.

Off

White

10

100

WCM35ICIW

Inside Corner Fitting. Used to join Cove Raceway at inside
corners. Maintains a minimum 25.4mm bend radius 
of cabling.

Off

White

1

10

WCM35OCIW

Outside Corner Fitting. Used to join Cove Raceway at
outside corners. Maintains a minimum 25.4mm bend radius
of cabling.

Off

White

1

10

WCM35TIW

Tee Fitting. Used to join sections of Cove Raceway to
form a “tee” junction.  Maintains a minimum 25.4mm bend
radius of cabling.

Off

White

1

10

WCM35TI

Tee Fitting Insert. Mounts inside Cove Raceway tee fitting
to maintain channel separation at tee junctions. Maintains
a minimum 25.4mm bend radius of cabling.

Grey

1

10

WCM35ECIW

End Cap Fitting. Used to terminate or enter Cove
Raceway. Includes breakouts for 12.70mm and 
19.05mm conduit.

Off

White

1

10

WCM35TRIW

Transition Fitting. Used to transition from Cove Raceway
to 

P

AN

-W

AY

T-45 Raceway or LD Series Raceways.

Off

White

1

10

WCM35TR5IW

Low Profile Transition Fitting. Used to transition from Cove
Raceway to LD/LDP5.

Off

White

1

10

WCM35TR10IW

Low Profile Transition Fitting. Used to transition from Cove
Raceway to LD/LDP10.

Off

White

1

10

WCM35TR70IW

Low Profile Transition Fitting. Used to transition from Cove
Raceway to T-70.

Off

White

1

10

WCM35DBFIW

Device Box and Faceplate Adapter. Used in Cove
Raceway to install single or double gang power and/or
data devices in-line. Will accept snap-on or screw-on
single gang faceplate or screw-on double gang faceplate.
NOTE: Will accept GFCI or TVSS outlets in single gang
configuration only. 

Off

White

1

10

WCM35BFIW

Backfeed Fitting. Inserts allow cable entry and exit through
the back of the raceway and conduit. Breakouts include
12.7mm, 19.05mm and 25.4mm.

Off

White

1

10

WCM35WR-X

Wire Retainer. Holds wires in place. Will not interfere with
cover installation.

Grey

10

0

WCM35CCIW-X

WCM35ICIW

WCM35OCIW

WCM35TIW

WCM35TI

WCM35ECIW

WCM35TRIW

WCM35BFIW

WCM35WR-X

WCM35TR5IW

WCM35TR10IW

WCM35TR70IW

WCM35DBFIW

Panduit-Pannet-html.html
background image

268

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Cable Fill Capacities for Cove Raceway

This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to
the cable installation methods, straightness of cables, etc.

Cable fill #1:

Open channel

without Devices.

A = 3484mm

2

Cable fill #2:

Open channel

with Wire Retainer.

Cable fill #3:

Divided channel

(power and data) with

Wire Retainer and Divider Wall.

3A = 1548mm

2

SPEC = 40% cable fill — 

The recommended design in cable capacity, 

leaves room for future moves, adds, and changes.

MAX for Data = 60% cable fill — 

The maximum cable quantity

based on cable interweaving and packing factors.

MAX for Power cable fill — 

The maximum of electrical cables

based on  UL temperature rise test.

Cable fill #4:

Divided Channel

(power and data) with Device Box

and Faceplate.

A = 1032.27mm

2

Cable fill #5:

Divided Channel

(power and data) with Low Profile

Transition Insert.

A = 1161.29 mm

2

CR-SR-Cove-Wirefill1

Raceway Type & Configuration

Fill

Area

mm

2

Electrical Cables 

Data Grade Cable Data Grade Cable

Audio/Video

Fibre Optic Cable 

14 AWG 12 AWG 10 AWG

24 AWG/UTP CM

24 AWG/UTP CM

RG6

2 Strand

THHN/T90

Cat 5e (4pr)

Cat 6 (4pr)

2.7mm

3mm

3.9mm

DIA. = 5.5mm

DIA. = 6.35mm

DIA. = 7mm

DIA. = 4.4mm

FILL

FILL

FILL

FILL

FILL

MAX

MAX

MAX

SPEC

MAX

SPEC

MAX

SPEC

MAX

SPEC

MAX

(UL Temp Rise Test)

(40%)

(60%)

(40%)

(60%)

(40%)

(60%)

(40%)

(60%)

1.

WCM35: No Devices.

3484

50

40

30

58

87

44

66

29

43

89

134

2. 

WCM35: Using Wire Retainer –
No Devices.

3225.8

50

40

30

54

81

41

61

26

40

83

124

3A.

WCM35: Power and data using Wire
Retainer and Divider Wall.

1548

25

38

19

28

13

19

39

58

3B.

1548

30

25

20

13

19

22

4A.

WCM35: Power and data using DBF.

1032.27

17

25

13

19

10

16

26

35

4B.

903.22

25

25

20

5A.

WCM35: Power and data using
Low Profile Transition Insert.

1161.29

25

25

20

19

29

14

22

12

18

29

44

5B.

25

38

19

28

13

19

39

58

A = 3225.8mm

2

3A = 1548mm

2

A = 903.22mm

2

A = 1548.38 mm

2

1548.38

Panduit-Pannet-html.html
background image

269

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

TG-70 N

ON

-M

ETALLIC

S

URFACE

R

ACEWAY

P

AN

-W

AY

TG-70 Non-Metallic Surface Raceway is a multi-channel raceway, which provides a

solution for routing copper, fibre optic and/or power cabling when maximum cable capacity

is required.

Large raceway channel provides maximum capacity

Fittings maintain 40mm bend radius control

Multi-channel two-piece design

Aesthetically pleasing

Lightweight

Tamper resistant

The TG-70 Raceway System consists of raceway base and cover, fittings, termination hardware and

accessories.

P

AN

-W

AY

TG-70 Raceway can mount NEMA standard screw-on faceplates or superior

P

AN

-W

AY

Snap-On Faceplates directly to the channel. Fittings for TG-70 are available to transition to

P

AN

-W

AY

T-45 and LD Raceway.

Panduit-Pannet-html.html
background image

270

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

TG-70 Raceway Roadmap

A

D

F

A

1

B

2

G

D

F

E

C

H

J

K

L

O

M

N

P

T

S

R

Q

See exploded

view 1

See exploded
view 2

See exploded

view 3

See exploded

view 4

Panduit-Pannet-html.html
background image

271

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

TG-70** — TG-70 Raceway
Base and Cover

TGEC** — TG-70  End Cap 

TGTR** — TG-70 
Transition Fitting

JBP2FS** — 

F

AST

-S

NAP

Double

Gang Power Rated Surface
Mount Box

T70PG** —Single Gang
Rectangular Electrical/
Communication 
Snap-on Faceplate

ERU20** — 20A Rectangular
Electrical Outlet

TG70BC** — TG-70 
Base Couplers

T70CC** — T-70 
Cover Couplers

TGOC** — TG-70 Outside
Corner Fitting

TGBF** — TG-70 
Backfeed Fitting

TGIC** — TG-70 Inside 
Corner Fitting

TG70HB3-X  — TG-70 
Hanging Box with Divider Wall 

TGRA** — TG-70 Right 
Angle Fitting

CPG** — Single Gang 
Rectangular Power and
Communication Faceplate

T70FV2** — Vertical 
Sloped Communication  
Snap-on Faceplate

T70DB-X — T-70 
Device Bracket 

TGT** — TG-70 Tee Fitting

TGEE** — TG-70 Entrance 
End Fitting

TGDW — TG-70 Raceway
Divider Wall

LD2P10** — Raceway 

TGTD — TG Tee Divider

A

1

B

2

G

D

F

E

C

H

J

K

L

O

M

N

UIT70FH4** — 

U

LTIMATE

ID

Sloped Horizontal 
Snap-on Faceplate

P

T

S

R

Q

1

Panduit-Pannet-html.html
background image

272

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

A.

T70FV2 = Vertical Sloped Communication 
Snap-on Faceplate.

B.

M

INI

-C

OM

Modules.

C.

T70PG = Single Gang Rectangular Electrical/
Communication Snap-on Faceplate.

D.

ERU20 = 20A Rectangular Electrical Outlet
(screws included).

E.

JBP2FS = 

F

AST

-S

NAP

Double Gang Power Rated 

Surface Mount Outlet Box.

Components Required

TG-70 Configurations

A.

T70PG = Single Gang Rectangular Electrical
Communication Faceplate.

B.

ERU20 = 20A Rectangular Electrical Outlet
(screws included).

C.

TG70HB3 = TG-70 3-Sided Hanging Box.

Components Required

Exploded view 1

Exploded view 2

A

B

C

A

B

C

D

E

Panduit-Pannet-html.html
background image

273

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

A.

CPG = Single Gang Rectangular Screw-on Faceplate
(screws included).

B.

M

INI

-C

OM

Modules. 

C.

T70DB = T70 Device Bracket. 

Components Required

TG-70 Configurations (continued)

A.

UIT70FH4 = 

U

LTIMATE

ID

Sloped Horizontal 

Snap-on Faceplate — 4 Port.

B.

M

INI

-C

OM

Modules.

Components Required

Exploded view 4

Exploded view 3

A

B

A

B

C

Panduit-Pannet-html.html
background image

274

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

-W

AY

TG-70 Surface Raceway System

• UL & CSA rated 600V; meets UL5A and CSA C22.2 

No. 62.1-03 standards

• Large cable capacity with aesthetically pleasing design
• Tamper resistant

• Compatible with NEMA standard faceplates or 

P

AN

-W

AY

Classic Series Snap-on Faceplates

• Transitions to 

PANDUIT

T-45 and LD Profile Raceway

• Supplied with pre-punched mounting holes

‡ For other colours replace IW (Off White) with EI (Electric Ivory).
Order number of feet required in multiples of standard carton quantity.

Part Number

Part Description

Raceway Size

Colour

Length

mm

Std. 
Ctn. 
Qty.

TG-70 Raceway Base and Cover — PACKAGED TOGETHER

TG70IW8

TG-70 Raceway Base and Cover in
2438.4mm and 3048mm lengths. Supplied
with pre-punched mounting holes.

135mm x 

68mm

Off

White 

2438.4

32

TG70IW10

3048

40

T-70/TG-70/Twin-70 Raceway Cover

T70CIW8

T-70, TG-70, TE-70 or Twin-70 Raceway
Cover in 2438.4mm and 3048mm lengths.

Off

White 

2438.4

96

T70CIW10

3048

120

TG Raceway Divider Wall

TGDW8

TG Raceway Divider Wall.  Snaps onto rails
in TG Raceway Base to create separate
channels. Must use wire retainers to ensure
channel separation per UL/CSA.  Available
in 2438.4mm and 3048mm lengths.

Grey 

2438.4

64

TGDW10

3048

80

TG70 

T70C

TGDW

TG-70

Internal Area = 6999.98mm

2

68mm

135mm

Panduit-Pannet-html.html
background image

275

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

TG-70 Raceway Fittings

• TG-70 fittings are designed to exceed the TIA/EIA-568-B and 569-B required minimum bend radius for high performance

copper and fibre optic cabling systems

‡ For other colours replace IW (Off White) with EI (Electric Ivory).

TGEC

TGEE

T70CC

TG70BC

TGSOC

TGT

TGOC

TGTD

TGIC

TGTR

TGSIC

TGRA

TGBF

TGBFI

Part Number

Part Description

Colour

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

T70CCIW-X

Cover Coupler Fitting. Used to join sections of cover together.

Off

White 

10

100

TG70BCIW-X

Base Coupler Fitting. Each piece includes 2 base coupler
halves for joining sections of TG-70 Base together.

Off

White 

10

TGRAIW

Right Angle Fitting. Used to join sections of TG Raceway at
90° flat junctions.

Off

White 

1

10

TGICIW

Inside Corner Fitting. Used to join sections of TG Raceway at
inside corners. Fittings adjust from 85° to 135° to adapt to
non-square corners.

Off

White 

1

TGSICIW

Inside Corner Fitting – Non-adjustable. Used to join sections
of TG Raceway at inside corners.

Off

White

1

10

TGOCIW

Outside Corner Fitting. Used to join sections of TG Raceway
at outside corners. Fittings adjust from 85° to 135° to adapt to
non-square corners.

Off

White 

1

TGSOCIW

Outside Corner Fitting – Non-adjustable. Used to join sections
of TG Raceway at outside corners.

Off

White

1

10

TGTIW

Tee Fitting. Used to join sections of TG Raceway at
tee intersections.

Off

White 

1

5

TGTD

Tee Divider Insert. Mounts inside TGT Tee Fitting to maintain
channel separation in TG Raceway at tee intersections.

Grey

1

5

TGECIW

End Cap. Used to terminate or allow entry to TG Raceway.
Two knockouts each for 16mm and 25.4mm conduit.

Off

White 

1

10

TGEEIW

Entrance End Fitting. Accepts large conduit, 50.8mm in line 

or

at a right angle. Maintains a 40mm bend radius with a
removable insert and channel separation.

Off

White 

1

10

TGTRIW

Transition Fitting from TG to T-45. Provides a tee transition
from TG Raceway to T-45 and LD series size 5 and 10. Use
with RF5X3 Reducer Fitting to transition to LD series size 3.

Off

White 

1

10

TGBFIW

Backfeed Fitting. Features breakouts to enter through the
bottom of the fitting and maintains bend radius control with a
removable, bend radius insert and channel separation.

Off

White 

1

10

TGBFI

Backfeed Fitting Insert. Removable and maintains bend
radius control.

Off

White

1

10

Panduit-Pannet-html.html
background image

276

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

-W

AY

TG-70 Raceway Accessories

• TG-70 accessories consist of device mounting brackets, standard faceplate brackets for data, wire retainers, and fibre spool

brackets. The three-sided hanging box is used to mount NEMA standard single gang outlet and communications devices

Part Number

Part Description

Colour

Std. 

Pkg.

Qty.

Std.
Ctn. 
Qty.

T70DB-X

Device Mounting Bracket. Used to mount NEMA
standard single gang electrical outlets and
communication devices with either screw-on or snap-on
single gang faceplates. Can be used with T-70, Twin-
70, and TG-70 Raceways.

Grey

10

T70SDB-X

Standard Faceplate Bracket. Used to mount NEMA
standard 70mm single gang screw-on
electrical/communication faceplates only.

Grey

10

TG70HB3-X

Three-sided Hanging Box. Mounts standard electrical
outlets or communication devices with either NEMA
standard single gang screw-on or

PANDUIT

Snap-on

Faceplates. When used with TGDW Divider Wall, box
separates and fully encloses device to provide
cabling separation.

Grey

10

TG70HB3GFCI-X

GFCI Three-sided Hanging Box. Accepts single gang
U.S. GFCI (ground fault circuit interrupter) standard
electrical devices. Provides increased internal area for
connections and excess wire.

Grey

10

TG70WR-X

Wire Retainer. Holds wires in place during installation.

Grey

10

100

TGFSB

Fiber Spool Bracket. Each piece consists of two halves
that snap into base of TG Raceway. Provides method
to contain one meter or more of fibre slack and acts as
a strain relief while maintaining a minimum 32mm bend
radius. Bracket separation can be adjusted to fit the
length of slack required.

Grey

1

10

T70DB-X

T70SDB-X

TG70HB3-X

TG70HB3GFCI-X

TG70WR-X

TGFSB

TGFSB installed in

TG-70 Raceway

Panduit-Pannet-html.html
background image

277

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

A = 6510mm

2

Cable Fill Capacities for TG-70 Raceway

This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to
the cable installation methods, straightness of cables, etc.

Cable fill #1:

With Data only

using Screw-on Faceplates

and devices.

Cable fill #2:

With Data only

using Snap-on Faceplates

and Wire Retainer.

Cable fill #3:

With Wire Retainer.

A =  7000mm

2

Cable fill #4:

Divided (see 5A

and 5B for power and

data applications).

A = 2038.71mm

2

Cable fill #5:

With Power and data

using Snap-on Faceplates and

3-Sided Power Box.

MAX for Data = 60% cable fill — 

The maximum cable quantity

based on cable interweaving and packing factors.

MAX for Power cable fill — 

The maximum number of electrical

cables based on UL temperature rise test.

CR-SR-TG70-Wirefill1

Raceway Type & Configuration

Fill

Area

mm

2

Electrical Cables 

Data Grade Cable Data Grade Cable

Audio/Video

Fibre Optic Cable 

14 AWG 12 AWG 10 AWG

24 AWG/UTP CM

24 AWG/UTP CM

RG6

2 Strand

THHN/T90

Cat 5e (4pr)

Cat 6 (4pr)

.105

.122

.153

DIA. = .217

DIA. = .250

DIA. = .275

DIA. = .175

FILL

FILL

FILL

FILL

FILL

MAX

MAX

MAX

SPEC

MAX

SPEC

MAX

SPEC

MAX

SPEC

MAX

(UL Temp Rise Test)

(40%)

(60%)

(40%)

(60%)

(40%)

(60%)

(40%)

(60%)

1.

TG70: Data only using Screw-on
Faceplates and Devices.

6510

92

138

82

123

53

80

164

247

2.

TG70: Data only using Snap-on
Faceplates and Wire Retainer.

6890.31

97

146

87

130

56

85

174

261

3.

TG70: Wire Retainer without devices.

7000

40

40

38

99

148

88

132

57

86

177

265

4A.

TG70: Divided power and data (A).

2038.71

28

28

26

28

43

25

38

17

25

51

77

4B.

TG70: Divided power and data (B).

4645.15

65

98

58

88

38

57

117

176

5A.

TG70: Power and data using Snap-on
Faceplates and 3 Sided Power Box (A).

1987.10

28

28

26

28

42

25

37

16

24

50

75

5B.

TG70: Power and data using Snap-on
Faceplates and 3 Sided Power Box (B).

3600

51

76

45

68

30

44

91

136

SPEC = 40% cable fill — 

The recommended design in cable capacity,

leaves room for future moves, adds, and changes.

A = 6890.31mm

2

A = 4645.15mm

2

A = 1987.10mm

2

A = 3600mm

2

Panduit-Pannet-html.html
background image

278

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Notes

Panduit-Pannet-html.html
background image

279

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

T-70 & T

WIN

-70 N

ON

-M

ETALLIC

S

URFACE

R

ACEWAY

P

AN

-W

AY

T-70 and Twin-70 Non-Metallic Surface Raceways are multi-channel raceways which

provide solutions for routing copper, fibre optic and/or power cabling along fixed perimeter walls.

T-70 features the 

W

ORKSTATION

O

UTLET

C

ENTER

Offset Box which provides an offset solution to

maximise channel capacity and outlet density. Twin-70 offers two totally independent channels

maintained throughout the system for independent access to power, copper and fibre optic cabling.

Aesthetically pleasing

Lightweight

Tamper resistant

Fittings maintain 25.4mm bend radius control

T-70 utilises a single channel with snap-in divider
wall to provide multi-channel capability

Twin-70 utilises two independent channels and
covers to provide multi-channel capability

The T-70 and Twin-70 raceway systems consist of raceway base and cover, fittings, termination

hardware and accessories.

P

AN

-W

AY

T-70 and Twin-70 raceway can mount NEMA standard 

screw-on faceplates or superior 

P

AN

-W

AY

Snap-on Faceplates directly to the channel. Fittings for

T-70 and Twin-70 are available to transition to T-70,Twin-70,T-45 and LD raceways.

Panduit-Pannet-html.html
background image

280

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

T-70 Raceway Roadmap

J

S

A

B

2

R

C

N

S

O

J

D

F

E

T

K

H

M

1

L

See exploded
view 1

See exploded

view 2

See exploded

view 4

G

J

S

K

See exploded

view 3

Q

P

Panduit-Pannet-html.html
background image

281

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

T70B**,  T70C** — T-70 Base 
and Cover

T70EC** — T-70 End Cap Fitting

T70TR** — T-70 
Transition Fitting

T70T** — T-70 Tee Fitting 
T70TD — T-70 Tee Divider

T70OC** — T-70 Outside
Corner Fitting

T70CC** — T-70 Cover 
Coupler Fitting

T70WC2** — T-70 Workstation
Outlet Center Offset box for 
Snap-On Faceplates

T70IC** — T-70 Inside 
Corner Fitting

T70PG** — Single 
Gang Rectangular 
Electrical Communication
Snap-On Faceplate

T70EE** — T-70 Entrance 
End Fitting

JBP2FS** — 

F

AST

-S

NAP

Double Gang Power Rated
Surface Mount Outlet Box

T70FV2** — Vertical 
Sloped Communication 
Snap-On Faceplate

T70DB-X — T-70 
Device Bracket

CPG** — Single 
Gang Rectangular 
Screw-On Faceplate

T70BC** — T-70 Base 
Coupler Fitting

ERU20** — 20A Rectangular
Electrical Outlet

UIT70FH2** — 

U

LTIMATE

ID

Sloped Horizontal 
Snap-On Faceplate

T70HB3-X — Three Sided
Hanging Box

T70DW — T-70 Divider Wall 

LD2P10** — LD2P10 Raceway

T70RA** — T-70 Right 
Angle Fitting

A

1

B

2

G

D

F

E

C

H

J

K

L

O

M

N

P

T

S

Q

1

T70BF** — T-70 Backfeed Fitting 

R

Panduit-Pannet-html.html
background image

282

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

T-70 Configurations

A

A.

T70WC2 = T-70 

W

ORKSTATION

O

UTLET

C

ENTER

Offset Box 

for Snap-on Faceplates.

B.

ERU20 = 20A Rectangular Electrical Outlet 
(screws included).

C.

M

INI

-C

OM

Modules.

D.

T70PG = Single Gang Rectangular Electrical/
Communication Snap-on Faceplate.

E.

UIT70FH2 = 

U

LTIMATE

ID

Sloped Horizontal Snap-on 

Faceplate — Two Port.

Components Required

A.

T70PG = Single Gang Rectangular Electrical/
Communication Snap-on Faceplate.

B.

ERU20 = 20A Rectangular Electrical Outlet 
(screws included).

C.

T70HB3-X = Three-Sided Hanging Box.

Components Required

Exploded view 1

Exploded view 2

B

C

D

E

A

B

C

Panduit-Pannet-html.html
background image

283

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

T-70 Configurations (continued)

A.

UIT70FH2 = 

U

LTIMATE

ID

Sloped Horizontal Snap-on 

Faceplate — Two Port.

B.

M

INI

-C

OM

Modules.

Components Required

A.

CPG = Single Gang Rectangular Screw-on Faceplates

(screws included).

B.

M

INI

-C

OM

Modules.

C.

T70DB-X = T-70 Device Bracket.

Exploded view 4

Exploded view 3

Components Required

A

B

A

B

C

Panduit-Pannet-html.html
background image

284

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Twin-70 Raceway Roadmap

C

F

A

B

2

G

1

D

F

E

C

K

H

S

M

L

R

Q

P

C

F

S

O

A

J

N

3

Panduit-Pannet-html.html
background image

285

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

T702EC** — Twin-70 
End Cap Fitting

T702TRL** — Twin-70
Transition Fitting

T70PG** — Single Gang
Rectangular Electrical/
Communication 
Snap-On Faceplate

T70FV2** — Vertical 
Sloped Communication 
Snap-On Faceplate

ERU20** — 20A Rectangular
Electrical Outlet

T702OC** — Twin-70 
Outside Corner Fitting

T702BC** — Twin-70 
Base Coupler Fitting

T70CC** — T-70 Cover 
Coupler Fitting

T702TR** — Twin-70 
Transition Fitting

T70RA** — T-70 Right 
Angle Fitting

T70EC** — T-70 End 
Cap Fitting

UIT70FH4** — 

U

LTIMATE

ID

Sloped Horizontal  
Snap-On Faceplate

T702RA** — Twin-70 
Right Angle Fitting

JBP2FS** — 

F

AST

-S

NAP

Double Gang Power Rated
Surface Mount Outlet Box 

T70DB-X** — T-70 
Device Mounting Bracket

T702T** — Twin-70 Tee Fitting 

T45B**, T45C** — T-45
Raceway Base and Cover 

T70B**, T70C** — T-70
Raceway Base and Cover 

T702IC** — Twin-70 
Inside Corner Fitting

A

B

3

G

D

F

E

C

H

J

K

L

O

M

N

P

S

Q

2

T702EE** — Twin-70 
Entrance End Fitting

R

T702B**, T70C** — T702
Raceway Base and Cover

1

Panduit-Pannet-html.html
background image

286

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

-W

AY

T-70 Surface Raceway System

• UL & CSA rated 600V; meets UL5A and CSA C22.2 

No. 62.1-03 standards

• Large cable capacity with aesthetically pleasing design
• Tamper resistant

• Compatible with NEMA standard 70mm faceplates or 

P

AN

-W

AY

Classic Series Snap-on Faceplates

• Transitions to 

PANDUIT

T-45 and LD Profile Raceways

• Supplied with pre-punched mounting holes

‡ For other colours replace IW (Off White) with EI (Electric Ivory), WH (White) or IG (International Grey...in
2488.4mm. lengths ONLY).
Order raceway base and cover separately.
Order number of feet required in multiples of standard carton quantity.

Part Number

Part Description

Raceway Size

Colour

Length

mm

Std. 
Ctn. 
Qty.

T-70 Raceway Base

T70BIW8

T-70 Raceway Base in 2438.4mm and
3048mm lengths. Supplied with 
pre-punched mounting holes.

103.4mm x

44.9mm 

Off

White 

2438.4

48

T70BIW10

3048

60

T-70/TG-70/Twin-70 Raceway Cover

T70CIW8

T-70, TG-70, TE-70 or Twin-70 Raceway
Cover in 2438.4mm and 3048mm lengths.

Off

White 

2438.4

96

T70CIW10

3048

120

T-70/Twin-70 Raceway Divider Wall

T70DW8

T-70/Twin-70 Raceway Divider Wall.
Snaps onto rails in T-70/Twin-70 Raceway
base to create separate channels. Must
use wire retainers to ensure channel
separation per UL/CSA. Available in
2438.4mm and 3048mm lengths.

Grey

2438.4

96

T70DW10

3048

120

T70B

T70C

T70DW

P

AN

-W

AY

T-70 Raceway Fittings

• T-70 fittings are designed to maintain the TIA/EIA 568-B and 569-B required minimum bend radius for high performance

copper and fibre optic cabling systems

T70BC

T70RA

T70IC

T70CC

Part Number

Part Description

Colour

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

T70CCIW-X

Cover Coupler Fitting. Used to join sections of
cover together.

Off

White 

10

100

T70BCIW-X

Base Coupler Fitting. Used to join sections of T-70
Raceway Base together.

Off

White 

10

T70RAIW

Right Angle Fitting. Used to join sections of T-70 Raceway
at right angles.

Off

White 

1

10

T70ICIW

Inside Corner Fitting. Used to join sections of T-70
Raceway at inside corners.

Off

White 

1

10

‡ For other colours replace IW (Off White) with EI (Electric Ivory), IG (International Grey), WH (White) or 
IG (International Grey).

Panduit-Pannet-html.html
background image

287

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

T-70 Raceway Fittings (continued)

T70BF

T70WC2

T70TRI

T70WC

T70BFI

T70EE

T70TR

T70TRC

T70TD

T70EC

T70WM40TR

T70OC

T70T

Std. 
Ctn. 
Qty.

Std. 

Pkg. 

Qty.

Colour

Part Description

Part Number

‡ For other colours replace IW (Off White) with EI (Electric Ivory), IG (International Grey), WH (White) or 
IG (International Grey).
* Wiremold is a registered trademark of the Wiremold Co.

T70OCIW

Outside Corner Fitting. Used to join sections of T-70
Raceway at outside corners.

Off

White 

1

10

T70TIW

Tee Fitting. Used to join sections of T-70 Raceway at
tee intersections.

Off

White 

1

10

T70TD

Raceway Divider Inserts (power & data applications).
Separates power and data within tee fitting when divider
wall is placed in top position.

Grey 1

10

T70ECIW

End Cap Fitting. Used to terminate or allow entry to T-70
Raceway with conduit breakouts of 12.7mm

Off

White 

1

10

T70EEIW

Entrance End Fitting. Conduit breakouts of 12.7mm,  19.05mm,
25.4mm, and 31.75mm which allows entry from ceiling or wall.

Off

White 

1

10

T70TRIW

Transition Fitting. Used to transition to any LD Profile or 
T-45 Raceway while maintaining channel separation.
Fitting includes bend radius insert.

Off

White 

1

10

T70TRCIW

Transition Fitting Cover. Used to transition to any LD
Profile or T-45 Raceway.

Off

White 

1

10

T70TRI

Divided Insert for T-70 to LD2P10. Maintains channel
separation within T70TR fitting.

Grey 1

10

T70WM40TRIW

Wiremold* to T-70 Transition Fitting. In-line transition fitting
from Wiremold G4000 to T-70 Raceway.

Off

White 

1

10

T70BFIW

Backfeed Fitting. Allows cable entry through the back of
the T-70 Raceway.

Off

White 

1

10

T70BFI

Backfeed Fitting Insert. Bend radius insert to be used
with T70BF.

Grey

1

10

T70WCIW

W

ORKSTATION

O

UTLET

C

ENTER

Offset Box for Screw-on

Faceplates. Two-piece box & bracket accept any NEMA
standard screw-on faceplate.

Off

White 

1

10

T70WC2IW

W

ORKSTATION

O

UTLET

C

ENTER

Offset Box for 

P

AN

-

W

AY

Snap-on Faceplates. Two-piece box & bracket accept any
standard electrical outlet. Accepts any 

P

AN

-W

AY

™ Snap-

on Electrical/Communication Faceplates.

Off

White 

1

10

Panduit-Pannet-html.html
background image

288

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

-W

AY

Twin-70 Surface Raceway System

• UL & CSA rated 600V; meets UL5A and CSA C22.2 

No. 62.1-03 standards

• Separate channels allow independent access to power and

communication cabling throughout the entire system

• Transitions to 

PANDUIT

T-70, T-45 and LD

Profile Raceways

• Compatible with NEMA standard 70mm faceplates or 

P

AN

-W

AY

Classic Series Snap-on Faceplates

• Tamper resistant
• Supplied with pre-punched mounting holes

‡ For other colours replace IW (Off White) with EI (Electric Ivory) or WH (White).

600mm of cover needed for every 300mm of Twin-70 Base.

Order number of feet required in multiples of standard carton quantity.

Part Number

Part Description

Raceway Size

Colour

Length

mm

Std. 
Ctn. 
Qty.

Twin-70 Raceway Base

T702BIW8

Twin-70 Raceway Base in 2438.4mm 
and 3048mm lengths. Supplied with 
pre-punched mounting holes.

183.64mm x

44.9mm

Off

White 

2438.4

24

T702BIW10

3048

30

T-70/TG-70/Twin-70 Raceway Cover

T70CIW8

T-70, TG-70, TE-70 or Twin-70 Raceway
Cover in 2438.4mm and 3048mm lengths.

Off

White 

2438.4

96

T70CIW10

3048

120

T-70 Raceway Divider Wall

T70DW8

T-70/Twin-70 Raceway Divider Wall.
Snaps onto rails in T-70/Twin-70 Raceway
base to create separate channels. Must
use wire retainers to ensure channel
separation per UL/CSA. Available in
2438.4mm and 3048mm lengths.

Grey

2438.4

96

T70DW10

3048

120

T702B 

T70C

T70DW

Panduit-Pannet-html.html
background image

289

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

Twin-70 Raceway Fittings

• Twin-70 fittings are designed to maintain the TIA/EIA-568-B and 569-B required minimum bend radius for high performance

copper and fibre optic cabling systems

‡ For other colours replace IW (Off White) with EI (Electric Ivory) or WH (White). T702TRI available in Grey only.

T702BC

T70CC

T702IC

T702OC

T702TR

T702RA

T702TRI

T702TRL

T702EE

T702T

T702EC

Part Number

Part Description

Colour

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

T70CCIW-X

Cover Coupler Fitting. Used to join sections of cover together.

Off

White 

10

100

T702BCIW-X

Base Coupler Fitting. Used for joining sections of Twin-70
Base together.

Off

White 

10

T702RAIW

Right Angle Fitting. Used to join sections of Twin-70 Raceway
at 90° flat junctions.

Off

White 

1

10

T702ICIW

Inside Corner Fitting. Used to join sections of Twin-70
Raceway at inside corners.

Off

White 

1

10

T702OCIW

Outside Corner Fitting. Used to join sections of Twin-70
Raceway at outside corners.

Off

White 

1

10

T702TIW

Tee Fitting. Used to join sections of Twin-70 Raceway at
tee intersections.

Off

White 

1

5

T702ECIW

End Cap Fitting. Conduit breakouts of 12.7mm for entry into
raceway channel.

Off

White 

1

10

T702EEIW

Entrance End Fitting. Conduit breakouts of 12.7mm, 25.4mm,
and 38.1mm for entry from ceiling or wall.

Off

White 

1

5

T702TRIW

Transition Fitting. Used to transition to T-70 Raceway.

Off

White 

1

5

T702TRLIW

Transition Fitting. Used to transition to any LD Profile or
T-45 Raceway.

Off

White 

1

5

T702TRI

Transition Divider Insert for T702 to T-70 or T702 to LD
Profile. Maintains channel separation within T702TR or
T702TRL fittings.

Grey

1

10

Panduit-Pannet-html.html
background image

290

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

-W

AY

T-70 & Twin-70 Raceway Accessories

• T-70 and Twin-70 accessories consist of device mounting brackets, snap-on device brackets, hanging boxes and three

sided hanging boxes used to mount NEMA standard single gang electrical outlets and or communication devices

Part Number

Part Description

Colour

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

T70DB-X

Device Mounting Bracket. Used to mount NEMA
standard single gang electrical outlets and
communication devices with either screw-on or 
snap-on single gang faceplates. Can be used with 
T-70, Twin-70 and TG-70 Raceways.

Grey

10

T70SDB-X

Standard Faceplate Bracket. Used to mount NEMA
standard 70mm single gang screw-on
electrical/communication faceplates only.

Grey

10

T70HB-X

Hanging Box. Used to mount NEMA standard single
gang electrical outlets and devices with either screw-
on or snap-on single gang faceplates when there are
communications cables in the raceway. For use in T-70
and Twin-70 Raceway only.

Grey

10

T70HB3-X

Three-sided Hanging Box. Used to mount NEMA
standard single gang electrical outlets and devices with
either screw-on or snap-on single gang faceplates
when there are communications cables in the raceway.
Box is low profile for increased channel capacity and
does not require breakout removal. For use with T-70
& Twin-70 Raceway only.

Grey

10

T70HB3GFCI-X

T70 GFCI Three-sided Hanging Box. Accepts single
gang U.S. GFCI (ground fault circuit interrupter)
standard electrical devices. Provides increased internal
area for connections and excess wire.

Grey

10

T70WR-X

Wire Retainer. Holds wires in place during installation.

Grey

10

100

T70S-X

Spacer Plate. Used to mount the CBX4 Surface Mount
Box onto the T70DB-X or T70HB-X / T70HB3-X.

10

T70FSB

Fibre Spool Bracket. Each piece consists of two halves
that snap into base of T-70 or Twin-70 Raceway.
Provides method to contain one meter or more of fibre
slack and acts as a strain relief while maintaining a
minimum 30mm bend radius. Bracket separation can
be adjusted to fit the length of slack required.

Grey

1

10

T70DB-X

T70SDB-X

T70HB-X

T70HB3-X

T70HB3GFCI-X

T70WR-X

T70FSB

T70S-X

Use the T70FSB with T-70 or Twin-70
Raceway to contain 1m or more of fibre slack
while maintaining a 30mm cable bend radius.
Brackets are adjustable for slack length.

Use T70S-X Spacer Plate for
mounting the CBX4 Surface Mount
Box on T-70 or T702.

Panduit-Pannet-html.html
background image

291

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Cable Fill Capacities for T-70 Raceway

This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to
the cable installation methods, straightness of cables, etc.

Cable fill #1:

Raceway with

no devices.

A = 3322mm

2

Cable fill #2:

Power and data using

Three-Sided Hanging Box and

Device Bracket.

A = 554.84mm

2

Cable fill #3:

Data only using

Vertical Sloped Screw-on

Communication Faceplates.

A = 2367.74mm

2

Cable fill #4:

Data only using

Horizontal Sloped Snap-on

Communication Faceplates.

A = 3038.70mm

2

Cable fill #5:

Power and data using the 

W

ORKSTATION

O

UTLET

C

ENTER

Offset Box.

A = 587.10mm

2

A = 2070.96mm

2

SPEC = 40% cable fill — 

The recommended design in cable capacity,

leaves room for future moves, adds and changes.

MAX for Data = 60% cable fill — 

The maximum cable quantity

based on cable interweaving and packing factors.

MAX for Power cable fill — 

The maximum of electrical cables

based on UL temperature rise test.

a

b

a

b

A = 1110mm

2

CR-SR-T70-Wire Fill1

Raceway Type & Configuration

Fill

Area

mm

2

Electrical Cables 

Data Grade Cable Data Grade Cable

Audio/Video

Fibre Optic Cable 

14 AWG 12 AWG 10 AWG

24 AWG/UTP CM

24 AWG/UTP CM

RG6

2 Strand

THHN/T90

Cat 5e (4pr)

Cat 6 (4pr)

2.7mm 3.0mm 3.8mm

DIA. = 5.5mm

DIA. = 6.35mm

DIA. = 6.9mm

DIA. = 4.4mm

FILL

FILL

FILL

FILL

FILL

MAX

MAX

MAX

SPEC

MAX

SPEC

MAX

SPEC

MAX

SPEC

MAX

(UL Temp Rise Test)

(40%)

(60%)

(40%)

(60%)

(40%)

(60%)

(40%)

(60%)

1.

T-70: No devices.

3322

24

20

15

55

83

41

62

27

41

86

129

2a.

T-70: Power and data using the Three-
Sided Hanging Box and Device Bracket.

554.84

14

11

7

9

14

7

10

5

7

14

21

2b.

1110

19

28

14

21

9

14

29

43

3.

T-70: Data only (Screw-on Faceplates).

39

59

29

44

19

29

67

101

4.

T-70: Data only (Snap-on Faceplates).

3038.70

50

76

38

57

25

37

83

125

5a.

T-70: Power and data using the

W

ORKSTATION

O

UTLET

C

ENTER

Offset Box.

587.10

14

11

7

9

14

7

11

5

7

15

23

5b.

33

50

25

38

17

25

52

78

2367.74

2070.96

Panduit-Pannet-html.html
background image

292

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Cable Fill Capacities for Twin-70 Raceway

This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to
the cable installation methods, straightness of cables, etc.

Cable fill #1:

Power and data

with no devices.

A = 1322.58mm

2

A = 922.58mm

2

SPEC = 40% cable fill — 

The recommended design in cable capacity,

leaves room for future moves, adds, and changes.

MAX for Data = 60% cable fill — 

The maximum cable quantity

based on cable interweaving and packing factors.

MAX for Power cable fill — 

The maximum of electrical cables

based on UL temperature rise test.

b

a

A = 2006.45mm

2

A =  2141.93mm

2

A = 2670.96

2

A = 1503.22mm

2

A = 2961.28

2

Cable fill #2:

One Twin-70

Channel with no devices.

Cable fill #3:

Data only using

Vertical Sloped Screw-on

Communication Faceplates.

Cable fill #4:

Power using

Device Bracket and NEMA stan-

dard 70mm Screw-on faceplates.

Cable fill #5:

Data only using

Horizontal Sloped Snap-on

Communication Faceplates.

Cable fill #6:

20A TVSS

Rectangular Outlet using

Device Bracket and Snap-on

Electrical/Communication Faceplate.

CR-SR-Tw70-Wire Fill1

Raceway Type & Configuration

Fill

Area

mm

2

Electrical Cables 

Data Grade Cable Data Grade Cable Audio/Video Fibre Optic Cable 

14 AWG 12 AWG 10 AWG

24 AWG/UTP CM

24 AWG/UTP CM

RG6

2 Strand

THHN/T90

Cat 5e (4pr)

Cat 6 (4pr)

2.7mm 3.0mm 3.8mm

DIA. = 5.5mm

DIA. = 6.35mm

DIA. = 6.9mm

DIA. = 4.4mm

FILL

FILL

FILL

FILL

FILL

MAX

MAX

MAX

SPEC

MAX

SPEC

MAX

SPEC MAX

SPEC

MAX

(UL Temp Rise Test)

(40%)

(60%)

(40%)

(60%)

(40%) (60%)

(40%)

(60%)

1a.

Twin-70: Power and data, without
devices.

1322.58

22

33

16

25

18

27

34

51

1b.

922.58

15

23

11

17

12

19

24

36

2.

Twin-70: One channel (no devices).

2961.28

49

74

37

56

24

36

76

115

3.

Twin-70: Data only (Screw-on Faceplate). 2006.45

33

50

25

38

16

25

52

78

4.

Twin-70: Power only (Screw-on Faceplate). 2141.93

15

13

13

35

53

27

40

18

26

55

83

5.

Twin-70: Data only (Snap-on Faceplate).

2670.96

44

67

33

50

22

33

69

103

6.

Twin-70: TVSS Power (Snap-on Faceplate). 1503.22

16

16

14

25

37

18

28

12

18

39

58

Panduit-Pannet-html.html
background image

293

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

T-45 N

ON

-M

ETALLIC

S

URFACE

R

ACEWAY

P

AN

-W

AY

T-45 Non-Metallic Surface Raceway is a multi-channel raceway, which provides a solution

for routing copper, fibre optic and/or power cabling along fixed perimeter walls. T-45 Surface

Raceway terminates using the T-45 Hinged Data and Power Brackets, T-45 Offset Box and select

P

AN

-W

AY

Surface Mount Outlet Boxes.

Multi-directional cover hinge allows cable installation
from either side

Hinged data and power brackets provide easy access
for terminating outlets

Aesthetically pleasing

Lightweight

Tamper resistant

Fittings maintain 25.4mm bend radius control

P

AN

-W

AY

T-45 Surface Raceway accepts NEMA standard screw-on faceplates for superior 

P

AN

-W

AY

Snap-on Faceplates when terminating with the T-45 Offset Box and Surface Mount Outlet Boxes.

Fittings for T-45 are available to transition to 

P

AN

-W

AY

LD Series Raceways.

Panduit-Pannet-html.html
background image

294

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

T-45 Raceway Roadmap

L

M

A

E

F

D

R

M

C

B

R

G

S

1

P

See exploded

view 1

See exploded

view 2

See exploded

view 4

J

R

H

See exploded

view 3

R

Q

2

O

N

K

Panduit-Pannet-html.html
background image

295

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

CPG** — Single Gang
Rectangular  Electrical/
Communication 
Screw-on Faceplate

T70PG** — Single Gang
Rectangular Electrical/
Communication 
Snap-On Faceplate

T45WC2** — T-45 Offset Box
for Snap-On Faceplates

UIT70FH4** — 

U

LTIMATE

ID

Sloped Horizontal 
Snap-On Faceplate

T45RA** — T-45 Right 
Angle Fitting

T45HEGB** — T-45 
Electrical Bracket

T45EE** — T-45 Entrance 
End Fitting

T45IC** — T-45 Inside 
Corner Fitting

T45WC** — T-45 Offset Box for
Screw-On Faceplates/Receptacles

J

K

L

O

M

N

P

S

Q

ERU20** — 20A Rectangular
Electrical Outlet

R

T45B**, T45C** — 
T-45 Raceway

T45EC** — T-45 End Cap Fitting

T45T**and T45TD — T-45 Tee
Fitting and Divider

JBP2FS** — 

F

AST

-S

NAP

Double

Gang Power Rated Surface
Mount Outlet Box

UIT70FV2** — 

U

LTIMATE

ID

Sloped Vertical 
Snap-On Faceplate

T45OC** — T-45 Outside
Corner Fitting

T45RLD** — T-45 
Reducer Fitting

JBP1** — Power Rated Single
Gang Two-Piece Box

T45HDB** — T-45 Snap-On
Hinged Data Bracket 

T45DW** — T-45 
Divider Wall

LDP10** — LDP Raceway 

A

1

B

2

G

D

F

E

C

H

1

Panduit-Pannet-html.html
background image

296

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

T-45 Configurations

A.

T70PG = Single Gang Rectangular Electrical/
Communication Snap-on Faceplate.

B.

ERU20 = 20A Rectangular Electrical Outlet
(screws included).

C.

T45WC = T-45 Offset Box for Screw-on 
Faceplates/Receptacles. 

Components Required

A.

T45HDB = T-45 Snap-on Hinged Data Bracket.

B.

M

INI

-C

OM

Modules.

Components Required

Exploded view 1

Exploded view 2

A

B

A

C

B

Panduit-Pannet-html.html
background image

297

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

A.

UIT70FH4 = 

U

LTIMATE

ID

Sloped Horizontal 

Faceplates — 4 Port.

B.

M

INI

-C

OM

Modules.

C.

T45WC2 = T-45 Offset Box for Snap-on Faceplates.

Components Required

A.

T45HEGB = T-45 Electrical Bracket for 
Rectangular Outlet.

B.

ERU20 = 20A Rectangular Electrical Outlet
(screws included).

Components Required

T-45 Configurations (continued)

Exploded view 3

Exploded view 4

A

C

B

A

B

Panduit-Pannet-html.html
background image

298

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

T-45

Internal Area = 1367.74mm

2

31.75mm

60.45mm

T45B

T45C

T45DW

P

AN

-W

AY

T-45 Surface Raceway System

• UL & CSA rated 600V; meets UL5A and CSA C22.2 

No. 62.1-03 standards

• Hinged cover allows easy access from either side
• Optional factory applied adhesive backing 

speeds installation

• Supplied with pre-punched mounting holes
• Tamper resistant
• Terminates using the T-45 Hinged Data and Power

Brackets, Offset Box, or Surface Mount Outlet 
Box solutions

‡ For other colours replace IW (Off White) with EI (Electric Ivory). 
Order base and cover separately
Order number of feet required in multiples of standard carton quantity.

Part Number

Part Description

Raceway Size

Colour

Length

mm

Std. 
Ctn. 
Qty.

T-45 Raceway Base with adhesive

T45BIW10-A

60.45 x 31.75

3048

200

T-45 Raceway Base without Adhesive

T45BIW8

T-45 Raceway Base in 2438.4mm and
3048mm lengths. Supplied with pre-
punched mounting holes.

Off

White 

2438.4

160

T45BIW10

3048

200

T-45 Raceway Cover

T45CIW8

T-45 Raceway Cover in 2438.4mm and
3048mm lengths. Can be hinged open
on either side of T-45 Base.

Off

White 

2438.4

160

T45CIW10

3048

200

T-45 Raceway Divider Wall

T45DW8

T-45 Divider Wall. Snaps onto rails in 
T-45 Raceway Base to create separate
channels. Must use wire retainers to ensure
channel separation per UL/CSA.  Available
in 2438.4mm and 3048mm lengths.

Grey

2438.4

160

T45DW10

3048

200

T45BIW8-A

T-45 Raceway Base in 2438.4mm and
3048mm lengths with adhesive. 
Supplied with pre-punched 
mounting holes.

60.45 x 31.75

Off

White 

2438.4

160

Panduit-Pannet-html.html
background image

299

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

Type T-45 Raceway Fittings

• T-45 fittings are designed to maintain the TIA/EIA-568-B and 569-B required minimum bend radius for high performance

copper and fibre optic cabling systems

‡ For other colours replace IW (Off White) with EI (Electric Ivory). T45TD, T45TRI, and T45WR-X available in
Grey only. 

T45T

T45TD

T45EC

T45EE

T45RLD

T45TRI

T45HDB

T45HEB

T45HEGB

T45WR-X

T45WC

T45WC2

T45CC

T45RA

T45IC

T45OC

Part Number

Part Description

Colour

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

T45CCIW-X

Cover Coupler Fitting. Used to join two pieces of T-45 
Cover together.

Off

White 

10

100

T45RAIW

Right Angle Fitting. Used to join sections of T-45 Raceway at
90° flat junction.

Off

White 

1

10

T45ICIW

Inside Corner Fitting. Used to join T-45 Raceway at 
inside corner.

Off

White 

1

10

T45OCIW

Outside Corner Fitting. Used to join T-45 Raceway at 90°
outside corner.

Off

White

1

10

T45TIW

Tee Fitting. Used to join T-45 Raceway at tee intersections.

Off

White 

1

10

T45TD

Divided Insert. Used to separate power and data within
the T45T.

Grey

1

10

T45ECIW

End Cap Fitting. Used to terminate T-45 Raceway.

Off

White 

1

10

T45EEIW

Entrance End Fitting. With knockouts for 12.7mm, 19.05mm
25.4mm and 31.75mm conduit which allows entry from ceiling
or wall.

Off

White 

1

10

T45RLDIW

Reducer Fitting. Reduces from T-45 to LD10 Profile
Raceway.

Off

White 

1

10

T45TRI

Provides bend radius control at transition from T-70 to T-45
when used with T70TR.

Grey

1

10

T45HDBIW

Snap-on Hinged Data Bracket. Used for mounting 
M

INI

-C

OM

and FJ

Modules vertically inline within T-45

Raceway and can be hinged opened on either side of
T-45 Base.

Off

White 

1

10

T45HEBIW

Electrical Bracket and Box. Used for mounting standard
duplex electrical outlets.

Off

White 

1

10

T45HEGBIW

Electrical Bracket and Box. Used for mounting standard
rectangular style electrical outlets.

Off

White 

1

10

T45WR-X

Wire Retainers. Used to hold wires in place 
during installation.

Grey 10

100

T45WCIW

Offset Box. Allows for the mounting of any standard electrical
or communication outlet offset from the raceway channel. 
Box accepts any NEMA standard screw-on faceplate or 
P

AN

-W

AY

Electrical Snap-on Faceplates.

Off

White 

1

10

T45WC2IW

Offset Box. Box accepts any 

P

AN

-W

AY

Communication

Snap-on Faceplates.

Off

White 

1

10

Panduit-Pannet-html.html
background image

300

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Cable fill #4:

Power and data using

a Wire Retainer and Divider Walls.

A = 283.87mm

2

Cable fill #5:

Power and data using the Offset Box.

B = 438.71mm

2

C = 283.87mm

2

A = 264.52mm

2

B = 683.87mm

2

Cable Fill Capacities for T-45 Raceway

This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according
to the cable installation methods, straightness of cables, etc.

Cable fill #1:

T-45 with no devices.

A = 1374.19mm

2

Cable fill #2:

T-45 with wire retain-

er.

A = 1109.68mm

2

Cable fill #3:

Power and data using

a Wire Retainer and Divider Wall.

B = 774.19mm

2

SPEC = 40% cable fill — 

The recommended design in cable capacity,

leaves room for future moves, adds, and changes.

MAX for Data = 60% cable fill — 

The maximum cable quantity

based on cable interweaving and packing factors.

MAX for Power cable fill — 

The maximum of electrical cables

based on UL temperature rise test.

A = 283.87mm

2

Cable fill #8:

Power and data Using

Electrical Bracket/Box and Hinged

Data Bracket.

A = 141.93mm

2

Cable fill #7:

Power and data using Hinged

Data Bracket with Divider Insert.

Cable fill #6:

Data only using

Hinged Data Bracket.

A = 1290.32mm

2

A = 335.48mm

2

B = 774.19mm

2

B = 322.58mm

2

CR-SR-T45-Wire Fill1

Raceway Type & Configuration

Fill

Area

mm

2

Electrical Cables 

Data Grade Cable Data Grade Cable Audio/Video

Fibre Optic Cable 

14 AWG 12 AWG 10 AWG

24 AWG/UTP CM

24 AWG/UTP CM

RG6

2 Strand

THHN/T90

Cat 5e (4pr)

Cat 6 (4pr)

2.7mm 3.0mm 3.8mm

DIA. = 5.5mm

DIA. = 6.35mm

DIA. = 6.9mm

DIA. = 4.4mm

FILL

FILL

FILL

FILL

FILL

MAX

MAX

MAX

SPEC

MAX

SPEC

MAX

SPEC

MAX

SPEC

MAX

(UL Temp Rise Test)

(40%)

(60%)

(40%)

(60%)

(40%) (60%)

(40%)

(60%)

1.

T-45: No devices.

1374.19

36

27

25

22

34

17

26

11

17

35

53

2.

T-45: No devices with wire retainer.

1109.68

36

27

25

18

27

14

21

9

14

28

42

3A.

T-45: Power and data with wire retainer 
& divider wall (2 channels).

12

11

8

4

7

3

5

2

3

7

10

3B.

774.19

12

19

9

14

6

10

16

29

4A.

T-45: Power and data with wire retainer 
& two divider walls (3 channels).

283.87

12

11

8

4

7

3

5

2

3

7

10

4B.

438.71

7

11

5

8

4

5

11

16

4C.

283.87

4

7

3

5

2

3

7

10

5A.

T-45: Power and data using the

W

ORKSTATION

O

UTLET

C

ENTER

Offset

Box.

264.52

12

11

8

4

6

3

5

2

3

6

10

5B.

683.87

11

17

8

12

6

8

17

26

6.

T-45: Data only using data bracket.

1290.32

21

32

16

24

11

16

33

49

7A.

T-45 Power and data using Hinged Data
Bracket with Divider Insert.

335.48

12

11

8

3

4

7B.

774.19

12

18

9

14

6

10

16

24

8A.

T-45: Power and data using Electrical
Bracket and Box.

141.93

9

7

4

1

2

8B.

332.58

5

8

4

6

3

4

8

12

283.87

Panduit-Pannet-html.html
background image

301

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

LD P

ROFILE

N

ON

-M

ETALLIC

S

URFACE

R

ACEWAY

P

AN

-W

AY

LD Profile Raceway is available in single and multi-channel styles to provide a solution for

routing copper, fibre optic and power cabling along fixed perimeter walls.

LD2P10 features one-piece multi-channel design
for both power and data applications

LDP features one-piece single channel design 
and a tamper resistant latch for power OR 
data applications

LD features one-piece single channel design for
data routing

LDS features one-piece single channel tamper
resistant design with maximum security for
power OR data applications

P

AN

-W

AY

LD Profile Raceways include a full complement of fittings for standard, bend radius

control, power rated and multi-channel use, and transition easily to other 

PANDUIT

raceway such

as Cove,TG-70,T-70,Twin-70 and T-45.

Panduit-Pannet-html.html
background image

302

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

LD2P10 Profile Raceway Roadmap

A

F

D

E

C

B

S

1

K

See exploded
view 1

See exploded

view 3

G

J

H

R

See exploded

view 2

E

L

M

E

N

P

Q

O

Panduit-Pannet-html.html
background image

303

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

CPG**-2G — Double 
Gang Rectangular 
Screw-On Faceplate

CPG** — Single 
Gang Rectangular 
Screw-On Faceplate

CFX10** — Power Rated 
Coupler Fitting

JBP1D** — Single Gang 
Two-Piece Deep Box

JBD1 — Single Gang 
Pass Through Divider 
for LD2P10 Raceway

UICFPSE2** — 

U

LTIMATE

ID™

2 Position Executive 
Sloped Faceplate

EEFX** — Power Rated/1"
Bend Radius Entrance 
End Fitting

ICFX10** — Power Rated 
Inside Corner Fitting

JBP1** — Power Rated Single
Gang Two-Piece Box

J

K

L

O

M

N

P

S

Q

RAFX10** — Power Rated 
Right Angle Fitting

R

LD2P10 Raceway

JBP2S** — Power Rated
Double Gang Three-Piece
Divided Box

FP2RC** —Double Gang
Rectangular Electrical & 2
Communication Insert
Faceplate

ERU20** — 20 A Rectangular
Electrical Outlet

OCFX10** — 1" Bend Radius
Outside Corner Fitting

JBD2 —Double Gang Pass
Through and Divider for
LD2P10 Raceway

JBP2D** —Power Rated Double
Gang Two-Piece Deep Box 

ECFX10** — Power Rated 
End Cap Fitting

TFXD10** — 1" Bend Radius
Tee Fitting

C

1

D

B

F

H

G

E

A

Panduit-Pannet-html.html
background image

304

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

LD2P10 Configurations

A.

M

INI

-C

OM

Modules.

B.

FP2RC = Double Gang Rectangular Electrical and Two 
Communication Insert Faceplate (screws included).

C.

ERU20 = 20A Rectangular Electrical Outlet
(screws included).

D.

JBP2S = Power Rated Double Gang Three-Piece
Divided Box (screws included).

Components Required

Exploded view 1

A

B

C

D

A

B

C

D

E

A.

JBD2 = Double Gang Pass Through Divider for
LD2P10 Raceway.

B.

JBP2D = Power Rated Double Gang Two-Piece
Deep Box.

C.

ERU20 = 20A Rectangular Electrical Outlet
(screws included).

D.

M

INI

-C

OM

Connectivity.

E.

CPG2G = Double Gang Rectangular Screw-On 
Faceplate (screws included).

Components Required

Exploded view 2

Panduit-Pannet-html.html
background image

305

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

LD2P10 Configurations (continued)

A.

UICFPSE2 = 

U

LTIMATE

ID

Two-Position Executive

Sloped Faceplate.

B.

M

INI

-C

OM

Modules.

C.

JBP1D = Power Rated Single Gang Two-Piece 
Deep Box (screws included).

D. 

JBD1 = Single Gang Pass Through Divider for 
LD2P10 Raceway.

Components Required

Exploded view 3

A

B

C

D

Panduit-Pannet-html.html
background image

306

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

LD Profile Raceway Roadmap

A

F

E

D

B

O

H

See exploded

view 1

See exploded

view 2

N

M

L

K

J

G

C

2

1

Panduit-Pannet-html.html
background image

307

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

ICF10** — Inside 
Corner Fitting

JB1FS** — 

F

AST

-S

NAP

Single Gang Surface 
Mount Outlet Box

UIT70FV4** — 

U

LTIMATE

ID

Sloped Vertical  Snap-On
Faceplates 4 Position

RAF10** — Right Angle Fitting 

DCF10** — Drop
Ceiling/Entrance End Fitting

JBP2FS** — 

F

AST

-S

NAP

Double Gang Power Rated
Surface Mount Outlet Box

UIT70FV2** — 

U

LTIMATE

ID

Sloped Vertical Snap-On
Faceplates 2 Position

H

J

K

N

L

M

O

LD10 Raceway

TF10** — Tee Fitting 

RF10X5** — Reducer Fitting 

JBX3510** — Single Gang
Two-Piece Snap-Together Box

CPG** — Single 
Gang Rectangular 
Screw-On Faceplate

CF10** — Coupler Fitting

OCF10** — Outside 
Corner Fitting

LD5 Raceway

ECF10** — End Cap Fitting

B

1

C

A

E

G

F

D

2

Panduit-Pannet-html.html
background image

308

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

LD Configurations

A. 

CPG = Single Gang Rectangular Screw-on
Faceplate (screws included).

B.

M

INI

-C

OM

Modules.

C.

JBX3510 = Single Gang Two-Piece Snap 
Together Box.

Components Required

Exploded view 1

A

B

C

Panduit-Pannet-html.html
background image

309

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

LD Configurations (continued)

A.

UIT70FV2 = 

U

LTIMATE

ID

Sloped Vertical 

Snap-on Faceplate — Two Port.

B.

M

INI

-C

OM

Modules.

C.

JBP2FS = 

F

AST

-S

NAP

Double Gang Power Rated

Surface Mount Outlet Box.

Components Required

Exploded view 2

A

B

C

Panduit-Pannet-html.html
background image

310

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

LDP Profile Raceway Roadmap

A

G

B

O

K

See exploded

view 1

See exploded

view 2

N

E

D

C

2

F

L

F

M

J

H

E

D

F

1

Panduit-Pannet-html.html
background image

311

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

CFX10** — Power Rated/1"
Bend Radius Coupler Fitting 

JBP2** — Power Rated Double
Gang Two-Piece Box

CPG**-2G — Double 
Gang Rectangular 
Screw-On Faceplates

RAFX10** — Power 
Rated Right Angle Fitting

DCEFX** — Power Rated/1"
Bend Radius Drop Ceiling
Entrance End Fitting

RAEFX** — Power Rated/1" 
Bend Radius Right Angle
Entrance End Fitting

ICFX10** — Power Rated 
Inside Corner Fitting

H

J

K

N

L

M

O

LDP10 Raceway 

TFX10** — Power Rated/1"
Bend Radius Tee Fitting 

RFX105** — Power Rated/1"
Bend Radius Reducer Fitting

JBP1** — Power Rated Single
Gang Two-Piece Box

CPG** — Single 
Gang Rectangular 
Screw-On Faceplate

OCFC10** — Power Rated
Outside Corner Fitting

ERU20** — 20 A
Rectangular Electrical Outlet

LDP5 Raceway

ECFX10** — Power Rated/1"
Bend Radius End Cap Fitting

B

1

C

A

E

G

F

D

2

Panduit-Pannet-html.html
background image

312

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

LDP Configurations

A.

CPG = Single Gang Rectangular Screw-on
Faceplate (screws included).

B.

ERU20 = 20A Rectangular Electrical Outlet 
(screws included).

C.

JBP1 = Power Rated Single Gang Two-Piece Box
(screws included).

Components Required

A.

CPG**2G = Double Gang Rectangular Screw-on
Faceplate (screws included).

B.

ERU20 = 20A Rectangular Electrical Outlet
(screws included).

C.

JBP2 = Power Rated Double Gang Two-Piece Box
(screws included).

Components Required

Exploded view 1

Exploded view 2

A

B

C

A

B

C

Panduit-Pannet-html.html
background image

313

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

Type LD2P10 Multi-Channel Surface Raceway System

• UL & CSA rated 600V; meets UL5A and CSA C22.2 

No. 62.1-03 standards

• Routes power & data together 
• One-piece hinged design allows cables to be laid in  
• Tamper resistant 

• Factory applied adhesive backing speeds installation 
• FT-4 Rated for Canada
• Terminates using JBP1D, JBP2D, JBP2FS, or JBP2S 

surface mount outlet box solutions

‡ For other colours replace IW (Off White) with EI (Electric Ivory), IG (International Grey), or WH (White).
LD2P Raceway requires screw mounting if it is being used for power cabling applications.
Order number of feet required in multiples of standard length increments.

Part Number

Part Description

Raceway

Size

Colour

Length

mm

Std. 
Ctn. 
Qty.

LD2P10IW8-A

Two channel tamper resistant one-piece
latching surface raceway. Supplied 
with pre-applied adhesive backed 
tape. Available in 2438.4mm and 
3048mm lengths.

38.4mm x

21.8mm

Off

White 

2438.4

160

LD2P10IW10-A

3048

200

LD2P10

CFX10

RAFX10

ICFX10

OCFX10

TFXD10

ECFX10

EEFX

277.41mm

2

258.06mm

2

21.8mm

38.4mm

Multi-Channel Fittings for LD2P10

• Multi-channel fittings for LD2P10 are designed to maintain the TIA/EIA-568-B and 569-B required minimum bend radius for

high performance copper and fibre optic cabling systems

Part Number

Part Description

Colour

Std. 

Pkg. 

Qty.

CFX10IW-X

Coupler Fitting for use with LD10, LDP10 and LD2P10 Raceway.

Off

White 

10

RAFX10IW-X

Right Angle Fitting for use with LDP10 and LD2P10 Raceway.

Off

White 

10

ICFX10IW-X

Inside Corner Fitting for use with LDP10 and LD2P10 Raceway.

Off

White 

10

OCFX10IW-X

Outside Corner Fitting for use with LDP10 and
LD2P10 Raceway.

Off

White 

10

TFXD10IW-X

Tee Fitting with divided insert to maintain separation of power
and data cabling. For use with LD2P10 Raceway.

Off

White 

10

ECFX10IW-X

End Cap Fitting for use with LDP10 and LD2P10 Raceway.

Off

White 

10

EEFXIW

Entrance End Fitting for LD2P10 Raceway. Breakouts for
12.7mm, 19.05mm and 25.4mm diameter conduit.

Off

White 

1

‡ For other colours replace IW (Off White) with EI (Electric Ivory), IG (International Grey) or WH (White).

Panduit-Pannet-html.html
background image

314

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

-W

AY

LD Surface Raceway System

• For routing data and low voltage cabling
• One-piece hinged design allows cables to be laid in  
• Factory applied adhesive backing speeds installation 

• FT-4 Rated for Canada
• Terminates using surface mount outlet box solutions or

M

INI

-C

OM

Surface Mount Boxes

‡ For other colours replace IW (Off White) with EI (Electric Ivory), IG (International Grey) or WH (White).
Order number of feet required in multiples of standard length increments.

Part Number

Part Description

Raceway

Size

Colour

Length

mm

Std.
Ctn.
Qty.

LD3 — Surface Raceway

LD3IW6-A

One-piece latching surface raceway. Supplied
with pre-applied adhesive backed tape.
Available in 1828.8mm, 2438.4mm and
3048mm lengths.

19.6mm x

11.7mm

Off

White 

1828.8

120

LD3IW8-A

2438.4

160

LD3IW10-A

3048

200

LD5 — Surface Raceway

LD5IW6-A

One-piece latching surface raceway. Supplied
with pre-applied adhesive backed tape.
Available in 1828.8mm, 2438.4mm and
3048mm lengths.

25.7mm x

15.24mm

Off

White 

1828.8

120

LD5IW8-A

2438.4

160

LD5IW10-A

3048

200

LD10 — Surface Raceway

LD10IW6-A

One-piece latching surface raceway. Supplied
with pre-applied adhesive backed tape.
Available in 1828.8mm, 2438.4mm and
3048mm lengths.

38.1mm x

23.9mm

Off

White 

1828.8

120

LD10IW8-A

2438.4

160

LD10IW10-A

3048

200

LD3

LD5

LD10

245.16mm

2

135.48mm

2

Panduit-Pannet-html.html
background image

315

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

AY

LDP Surface Raceway System

• UL & CSA rated 600V; meets UL5A and CSA C22.2 No.

62.1-03 standards

• One-piece hinged design allows cables to be laid in  
• Tamper resistant  

• Factory applied adhesive backing speeds installation 
• FT-4 Rated for Canada
• Terminates using surface mount outlet box solutions or

M

INI

-C

OM

Surface Mount Boxes

‡ For other colours replace IW (Off White) with EI (Electric Ivory), IG (International Grey) or WH (White).
LDP Raceway requires screw mounting for power cabling applications.
Order number of feet required in multiples of standard length increments. 

Part Number

Part Description

Raceway

Size

Colour

Length

mm

Std. 
Ctn. 
Qty.

LDP3 — Surface Raceway

LDP3IW8-A

Tamper resistant one-piece latching
surface raceway. Supplied with pre-applied
adhesive backed tape. Available in
2438.4mm and 3048mm lengths.

19.6mm x

11.7mm

Off

White 

2438.4

160

LDP3IW10-A

3048

200

LDP5 — Surface Raceway

LDP5IW8-A

Tamper resistant one-piece latching
surface raceway. Supplied with pre-applied
adhesive backed tape. Available in
2438.4mm and 3048mm lengths.

25.4mm x

15.24mm

Off

White 

2438.4

160

LDP5IW10-A

3048

200

LDP10 — Surface Raceway

LDP10IW8-A

Tamper resistant one-piece latching
surface raceway. Supplied with pre-applied
adhesive backed tape. Available in
2438.4mm and 3048mm lengths.

38.4mm x

21.8mm

Off

White 

2438.4

160

LDP10IW10-A

3048

200

LDP10

LDP5

LDP3

LDP10

Internal Area = 632.25mm

2

LDP5

Internal Area = 245.16mm

2

LDP3

Internal Area = 135.48mm

2

Panduit-Pannet-html.html
background image

316

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

-W

AY

LDS Surface Raceway System

• UL & CSA rated 600V; meets UL5A and CSA C22.2 

No. 62.1-03 standards

• Tamper resistant non-hinged design
• Factory applied adhesive backing speeds installation
• FT-4 Rated for Canada 

• Type LDS is 

the only non-metallic raceway that is 

bendable

in low voltage applications to route around and

over obstructions

• LDS Raceway requires screw mounting using the LMD

mounting straps for power cabling installations

• Terminates using surface mount outlet box solutions or

M

INI

-C

OM

Surface Mount Boxes

‡ For other colours replace IW (Off White) with EI (Electric Ivory), IG (International Grey) or WH (White). 
Order number of feet required in multiples of standard length increments.

Part Number

Part Description

Raceway Size

Colour

Length

mm

Std. 
Ctn. 
Qty.

LDS3 — Surface Raceway

LDS3IW10-A

Tamper resistant one-piece surface
raceway. Supplied with pre-applied
adhesive backed tape.  Available in
3048mm lengths.

19.6mm x

10.4mm

Off

White 

3048

200

LDS5 — Surface Raceway

LDS5IW10-A

Tamper resistant one-piece surface
raceway. Supplied with pre-applied
adhesive backed tape.  Available in
3048mm lengths.

25.7mm x

13.97

Off

White 

3048

200

Mounting Straps

LMD3IW-Q

For use with LDS3 Raceway.

Size 3

Off

White 

100

LMD5IW-Q

For use with LDS5 Raceway.

Size 5

Off

White 

100

LDS3

LDS5

LMD3
LMD5

135.48mm

2

245.16mm

2

Method for Bending Type LDS Raceway (Low Voltage Applications)

STEP 1:

Slide 457.2mm to 762mm section of LDS

Raceway into PVC pipe heating blanket.
* (Recommended blanket designed for bending
12.7mm to 38.1mm PVC conduit.)

STEP 2:

Allow section to heat approximately

2-3 minutes. Raceway will be soft and pliable,
but should not stretch. (Time will vary with
blanket temperature and raceway size.)

STEP 3:

Remove raceway section from blanket

and hold in desired position until the raceway
cools. Install mounting straps immediately.

*Heating blanket not offered by 

PANDUIT

.

Panduit-Pannet-html.html
background image

317

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Standard Fittings for Low Voltage Applications

‡ For other colours replace IW (Off White) with EI (Electric Ivory), IG (International Grey), or WH (White).

Part Number

Part Description

Colour

Std. 

Pkg. 

Qty.

CF3IW-E

Coupler Fitting for use with LD3 Raceway.

Off

White 

20

CF5IW-E

Coupler Fitting for use with LD5 Raceway.

Off

White 

20

CF10IW-X

Coupler Fitting for use with LD10 Raceway.

Off

White 

10

RAF3IW-E

Right Angle Fitting for use with LD3 Raceway.

Off

White 

20

RAF5IW-E

Right Angle Fitting for use with LD5 Raceway.

Off

White 

20

RAF10IW-X

Right Angle Fitting for use with LD10 Raceway.

Off

White 

10

ICF3IW-E

Inside Corner Fitting for use with LD3 Raceway.

Off

White 

20

ICF5IW-E

Inside Corner Fitting for use with LD5 Raceway.

Off

White 

20

ICF10IW-X

Inside Corner Fitting for use with LD10 Raceway.

Off

White 

10

OCF3IW-E

Outside Corner Fitting for use with LD3 Raceway.

Off

White 

20

OCF5IW-E

Outside Corner Fitting for use with LD5 Raceway.

Off

White 

20

OCF10IW-X

Outside Corner Fitting for use with LD10 Raceway.

Off

White 

10

TF3IW-E

Tee Fitting for use with LD3 Raceway.

Off

White 

20

TF5IW-E

Tee Fitting for use with LD5 Raceway.

Off

White 

20

TF10IW-X

Tee Fitting for use with LD10 Raceway.

Off

White 

10

ECF3IW-E

End Cap Fitting for use with LD3 Raceway.

Off

White 

ECF5IW-E

End Cap Fitting for use with LD5 Raceway.

Off

White 

ECF10IW-X

End Cap Fitting for use with LD10 Raceway.

Off

White 

CRFC5IW-X

Four Way Cross Fitting for use with LD5, LDP5 and LDS5
Raceway.

Off

White 

10

DCF3IW-X

Drop Ceiling/Entrance End Fitting for use with LD3 Raceway.

Off

White 

10

DCF5IW-X

Drop Ceiling/Entrance End Fitting for use with LD5 Raceway.

Off

White 

10

DCF10IW-X

Drop Ceiling/Entrance End Fitting for use with LD10 Raceway.

Off

White 

10

FBA5IW-X

Fire Box Adapter for use with LD5/LDP5 and LD10/LDP10 Profile
Raceway. 

NOTE:  For low voltage applications only.

Off

White

10

FBA10IW-X

Fire Box Adapter for use with LD5/LDP5 and LD10/LDP10 Profile
Raceway. 

NOTE:  For low voltage applications only.

Off

White

10

RF5X3IW-E

Reducer Fitting for LD Raceway from size 5 to size 3. For use with
LD5 and LD3 Raceway.

Off

White 

20

RF10X3IW-X

Reducer Fitting for LD Raceway from size 10 to size 3. For use with
LD3 and LD10 Raceway.

Off

White 

10

RF10X5IW-X

Reducer Fitting for LD Raceway from size 10 to size 5. For use with
LD5 and LD10 Raceway.

Off

White 

10

CF

RAF

ICF

OCF

TF

ECF

CRFC

DCF

FBA

RF

Panduit-Pannet-html.html
background image

318

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

CFX

RAFC

ICFC

OCFX

TFC

CRFC5

ECFX

DCEFX

RAEFX

RFX

One Inch Bend Radius Fittings for TIA/EIA Compliance

• One inch bend radius fittings are designed to maintain the TIA/EIA-568-B and 569-B required minimum bend radius for

high performance copper and fibre optic cabling systems

‡ For other colours replace IW (Off White) with EI (Electric Ivory), IG (International Grey), or WH (White).

Part Number

Part Description

Colour

Std. 

Pkg. 

Qty.

CFX3IW-X

Coupler Fitting for use with LD3, LDP3 and LDS3 Raceway.

Off

White 

10

CFX5IW-X

Coupler Fitting for use with LD5, LDP5 and LDS5 Raceway.

Off

White 

10

CFX10IW-X

Coupler Fitting for use with LD10, LDP10 and LD2P10 Raceway.

Off

White 

10

RAFC3IW-X

Right Angle Fitting for use with LD3, LDP3 and LDS3 Raceway.

Off

White 

10

RAFC5IW-X

Right Angle Fitting for use with LD5, LDP5 and LDS5 Raceway.

Off

White 

10

RAFC10IW-X

Right Angle Fitting for use with LD10 and LDP10 Raceway.

Off

White 

10

ICFC3IW-X

Inside Corner Fitting for use with LD3, LDP3 and LDS3 Raceway.

Off

White 

10

ICFC5IW-X

Inside Corner Fitting for use with LD5, LDP5 and LDS5 Raceway.

Off

White 

10

ICFC10IW-X

Inside Corner Fitting for use with LD10 and LDP10 Raceway.

Off

White 

10

OCFX3IW-X

Outside Corner Fitting for use with LDP3 and LDS3 Raceway.

Off

White 

10

OCFX5IW-X

Outside Corner Fitting for use with LDP5 and LDS5 Raceway.

Off

White 

10

OCFX10IW-X

Outside Corner Fitting for use with LDP10 and LD2P10 Raceway.

Off

White 

10

TFC3IW-X

Tee Fitting for use with LD3, LDP3 and LDS3 Raceway.

Off

White 

10

TFC5IW-X

Tee Fitting for use with LD5, LDP5 and LDS5 Raceway.

Off

White 

10

TFC10IW-X

Tee Fitting for use with LD10 and LDP10 Raceway.

Off

White 

10

CRFC5IW-X

Four Way Cross Fitting for use with LD5, LDP5 and LDS5
Raceway.

Off

White 

10

ECFX3IW-X

End Cap Fitting for use with LDP3 and LDS3 Raceway.

Off

White 

10

ECFX5IW-X

End Cap Fitting for use with LDP5 and LDS5 Raceway.

Off

White 

10

ECFX10IW-X

End Cap Fitting for use with LDP10 and LD2P10 Raceway.

Off

White 

10

DCEFXIW-X

Drop Ceiling/Entrance End Fitting for use with LD3, LDP3, LDS3,
LD5, LDP5, LDS5, LD10 and LDP10 Raceway. Use CA3 or CA5
adapters for LD3 or LD5 Profile Raceway.

Off

White 

10

RAEFXIW-X

Right Angle/Entrance End Fitting for use with LD3, LDP3, LDS3,
LD5, LDP5, LDS5, LD10 and LDP10 Raceways. CA3 or CA5
adapters for LD3 or LD5 Profile Raceway.

Off

White 

10

RFX53IW-X

Reducer Fitting for use with LD3, LDP3, LDS3, LD5, LDP5 and
LDS5 Raceway.

Off

White 

10

RFX103IW-X

Reducer Fitting for use with LD3, LDP3, LDS3, LD10 and
LDP10 Raceway.

Off

White 

10

RFX105IW-X

Reducer Fitting for use with LD5, LDP5, LDS5, LD10 and
LDP10 Raceway.

Off

White 

10

Panduit-Pannet-html.html
background image

319

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Power Rated Fittings for Power to 600V —  LDP / LDS / LD2P
Raceway Only

Part Number

Part Description

Colour

Std. 

Pkg. 

Qty.

CFX3IW-X

Coupler Fitting for use with LD3, LDP3 and LDS3 Raceway.

Off

White 

10

CFX5IW-X

Coupler Fitting for use with LD5, LDP5 and LDS5 Raceway.

Off

White 

10

CFX10IW-X

Coupler Fitting for use with LD10, LDP10 and LD2P10 Raceway.

Off

White 

10

RAFX3IW-X

Right Angle Fitting for use with LDP3 and LDS3 Raceway.

Off

White 

10

RAFX5IW-X

Right Angle Fitting for use with LDP5 and LDS5 Raceway.

Off

White 

10

RAFX10IW-X

Right Angle Fitting for use with LDP10 and LD2P10 Raceway.

Off

White 

10

ICFX3IW-X

Inside Corner Fitting for use with LDP3 and LDS3 Raceway.

Off

White 

10

ICFX5IW-X

Inside Corner Fitting for use with LDP5 and LDS5 Raceway.

Off

White 

10

ICFX10IW-X

Inside Corner Fitting for use with LDP10 and LD2P10 Raceway.

Off

White 

10

OCFC3IW-X

Outside Corner Fitting for use with LDP3 and LDS3 Raceway.

Off

White 

10

OCFC5IW-X

Outside Corner Fitting for use with LDP5 and LDS5 Raceway.

Off

White 

10

OCFC10IW-X

Outside Corner Fitting for use with LDP10 Raceway only.

Off

White 

10

TFX3IW-X

Tee Fitting for use with LDP3 and LDS3 Raceway.

Off

White 

10

TFX5IW-X

Tee Fitting for use with LDP5 and LDS5 Raceway.

Off

White 

10

TFX10IW-X

Tee Fitting for use with LDP10 Raceway only.

Off

White 

10

CRFX5IW-X

Four Way Cross Fitting for use with LD5, LDP5 and LDS5
Raceway.

Off

White 

10

ECFX3IW-X

End Cap Fitting for use with LDP3 and LDS3 Raceway.

Off

White 

10

ECFX5IW-X

End Cap Fitting for use with LDP5 and LDS5 Raceway.

Off

White 

10

ECFX10IW-X

End Cap Fitting for use with LDP10 and LD2P10 Raceway.

Off

White 

10

DCEFXIW-X

Drop Ceiling/Entrance End Fitting for use with LD3, LDP3, LDS3,
LD5, LDP5, LDS5, LD10 and LDP10 Raceway. Use CA3 or CA5
adapters for LD3 or LD5 Profile Raceway.

Off

White 

10

RAEFXIW-X

Right Angle/Entrance End Fitting for use with LD3, LDP3, LDS3,
LD5, LDP5, LDS5, LD10 and LDP10 Raceways. CA3 or CA5
adapters for LD3 or LD5 Profile Raceway.

Off

White 

10

RFX53IW-X

Reducer Fitting for use with LD3, LDP3, LDS3, LD5, LDP5 and
LDS5 Raceway.

Off

White 

10

RFX103IW-X

Reducer Fitting for use with LD3, LDP3, LDS3, LD10 and
LDP10 Raceway.

Off

White 

10

RFX105IW-X

Reducer Fitting for use with LD5, LDP5, LDS5, LD10 and
LDP10 Raceway.

Off

White 

10

‡ For other colours replace IW (Off White) with EI (Electric Ivory), IG (International Grey), or WH (White).

ICFX

OCFC

TFX

CRFX

ECFX

DCEFX

RAEFX

RFX

CFX

RAFX

Panduit-Pannet-html.html
background image

320

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Raceway Adapters for LD Raceway

• Fits into universal breakout of DCEFX or RAEFX fittings 
• For use with Types LD3, LDP3 and LDS3 and LD5, LDP5 

and LDS5 Raceways

‡ For other colours replace IW (Off White) with EI (Electric Ivory), IG (International Grey), or WH (White).

Part Number

Part Description

Colour

Std. 

Pkg. 

Qty.

Std. 
Ctn. 
Qty.

CA3IW-X

Fits into universal breakout of DCEFX or RAEFX fittings. For
use LD3, LDP3 and LDS3 Raceway.

Off

White 

10

50

CA5IW-X

Fits into universal breakout of DCEFX or RAEFX fittings. For
use LD5, LDP5 and LDS5 Raceway.

Off

White 

10

50

Cable Fill Capacities for LD Profile Raceway

This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according
to the cable installation methods, straightness of cables, etc.

LD2P10 — Left

277.41mm

2

SPEC = 40% cable fill — 

The recommended design in cable capacity,

leaves room for future moves, adds and changes.

MAX for Data = 60% cable fill — 

The maximum cable quantity

based on cable interweaving and packing factors.

MAX for Power cable fill — 

The maximum of electrical cables

based on UL temperature rise test.

LDP210 — Right

322.58mm

2

LD3

135.48mm

2

LD5

245.16mm

2

LD10

645.16mm

2

LDS3

135.48mm

2

LDS5

245.16mm

2

Raceway Type & Configuration

Fill Area

mm

2

Electrical Cables 

Data Grade Cable Data Grade Cable

Audio/Video

Fibre Optic Cable 

14 AWG 12 AWG 10 AWG

24 AWG/UTP CM

24 AWG/UTP CM

RG6

2 Strand

THHN/T90

Cat 5e (4pr)

Cat 6 (4pr)

2.7mm 3.0mm 3.8mm

DIA. = 5.5mm

DIA. = 6.35mm

DIA. = 6.9mm

DIA. = 4.4mm

FILL

FILL

FILL

FILL

FILL

MAX

MAX

MAX

SPEC

MAX

SPEC

MAX

SPEC

MAX

SPEC

MAX

(UL Temp Rise Test)

(40%)

(60%)

(40%)

(60%)

(40%)

(60%)

(40%)

(60%)

LD3

135.48

2

3

1

2

1

2

4

5

LD5

245.16

4

6

3

4

2

3

6

9

LD10

645.16

10

16

8

12

5

8

16

24

LDP3

135.48

9

7

4

2

3

1

2

1

2

3

5

LDP5

245.16

14

12

8

4

6

3

4

2

3

6

9

LDP10

645.16

18

18

16

10

15

7

11

5

8

16

16

LD2P10-Left Channel.

277.41

14

11

8

4

6

3

5

2

3

7

11

LD2P10-Right Channel.

322.58

5

8

4

6

3

4

8

12

LDS3

135.48

9

6

4

2

3

1

2

1

2

3

5

LDS5

245.16

10

8

5

4

6

3

4

2

3

6

9

CA3
CA5

LDP3

135.48mm

2

LDP5

245.16mm

2

LDP10

645.16mm

2

Panduit-Pannet-html.html
background image

321

C

ABLE

T

IES

& A

CCESSORIES

PANDUIT

is a leading global producer of  communication products, including cable ties and

cable management accessories. We continually provide new cable tie and accessory designs to

meet the application challenges encountered by our customers while providing the lowest

installed cost.

PANDUIT

offers unique products to meet customer needs:

T

AK

-T

Y

Hook & Loop Cable Ties - prevent over-tensioning of high performance cables

C

ONTOUR

-T

Y

Cable Ties - low profile head and smooth, round edges 

B

ELT

-T

Y

In-Line Cable Ties - head design prevents protrusion of cut-off tie 

T

AK

-T

Y

Hook & Loop Cable Tie Mounts - designed to secure bundles of 

communications  wiring 

J-M

OD

Cable Support System - versatile solution for communication cable management

P

AN

-S

TEEL

Self-Locking Stainless Steel Ties - feature the highest tensile strength, quickest

lock up and lowest installation time, with fully rounded edges for added protection and safety

P

AN

-W

RAP

Split Harness Wrap - engineered for flexibility and maximum protection of wires

and cables

Please refer to catalogue “Cable Tie and Wiring Accessories” for information on the complete 

PANDUIT

line of cable ties and cable management accessories.

Hook & Loop cable ties are releasable and reusable;
ideal for communications applications

Parallel entry ties are designed to eliminate
protrusion of cut-off tie 

Nylon cable ties offered in the largest selection of

styles, sizes and colours

Select cable tie sizes are available in HALAR

s

,

Tefzel

n

, Acetal and Polypropylene to meet your

application needs

Full line of accessories specifically designed to route
and secure communication cable 

Stainless steel cable ties withstand virtually 
any environment

•  Complete line of abrasion protection and heat

shrink products

s

HALAR is the registered trademark for Ausimont, Inc. Fluoropolymer

n

Tefzel is the registered trademark for E.I. DuPont Co. Fluoropolymer

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

322

Prime items appear in 

BOLD

.

T

AK

-T

Y

Hook & Loop Cable Ties

• Material has hooks on one side and loops on the other 

so it adheres to itself

• Releasable and reusable hundreds of times and no

installation tool needed

• No risk of over-tensioning and damaging high 

performance cabling

• No waste since excess can be wrapped around bundle
• A variety of colours are available for HLM, HLS and 

HLT styles

• HLSP and HLTP (black and maroon) are unique Hook &

Loop style ties that are UL Listed (File #E56854) for use in
air handling spaces, per NEC, Section 300-22(c) and (d),
and are UL94V-2 flame rated     

• HLM series may be used with ABM3H, ABM4H and TMEH

mounts  (see pages 336 and 337)

• HLT series may be used with TMEH mount
• All styles may be used with ABMT mount (see page 336)

Note:

Minimum 50mm overlap required to achieve loop 
tensile rating (HLC, HLT, HLS and HLM series); and 
UL Listed Rated Load (HLSP / HLTP series)

HLT / HLTP

+ Also available in Black (-X0), which has an 80N minimum loop tensile strength

HLS / HLSP / HLM

HLTP / HLSP Only

HLC

Part Number

Length

Width

Max. Bundle

Dia.

Min. Loop

Tensile Str.

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

N

Cinch Ties - Provide extra strength and bundle tightness  

HLC3S-X0

305

19.1

76

222

10

100

HLC5S-X0

457

19.1

127

222

10

100

Loop Ties - Slot allows for pre-wrapping of bundles  

HLT2I-X0

203

12.7

49

178

10

100

HLT3I-X0

305

12.7

81

178

10

100

Strip Ties - Rolls perforated in convenient 152.4mm, 304.8mm, and 457.2mm strips  

HLTP2I-X12

203

12.7

49

178

10

100

HLTP3I-X12

305

12.7

81

178

10

100

Strip Ties - Rolls perforated in convenient 152.4mm, 304.8mm, and 457.2mm strips  

HLS1.5S-X0

152

19.1

38

222

10

100

HLS3S-X0

305

19.1

81

222

10

100

HLS5S-X0

457

19.1

127

222

10

100

UL Listed Loop Ties+

HLSP1.5S-X12

152

19.1

38

222

10

100

HLSP3S-X12

305

19.1

81

222

10

100

HLSP5S-X12

457

19.1

127

222

10

100

15' & 75' Rolls - Can be cut to desired length, eliminating waste  

HLM-15R0

4,572

8.4

Various

80

1

10

HLS-15R0

4,572

19.1

Various

222

1

10

HLS-75R0

22,860

19.1

Various

222

1

10

Panduit-Pannet-html.html
background image

323

T

AK

-T

APE

Hook & Loop Strips

• Hook & Loop fastener for general 

purpose bundling

• Thin and flexible to quickly wrap 

around bundle

• Adjustable, releasable and reusable
• Large continuous roll you can cut to size

with Telco snips, scissors or 

PANDUIT

cutter (included with TTS-35RX0 only)

• Wide 19.05mm black strap spreads out

bundling forces over large area

• May be used with ABMT mount 

(see page 336)          

• Handy, reusable plastic case (TTS20)

keeps material clean

Note

:   Minimum 50.8mm overlap required

to achieve loop tensile rating

Std. Pkg. Qty. of TTS-35RX0 denotes 1 package of ten 35' rolls

TTS-20R0

C

ONTOUR

-T

Y

Cable Ties

• Low profile head and smooth, round edges, prevent 

cable damage

• Unique design avoids abrasion to cables
• Parallel entry limits exposure to sharp edges to protect

adjacent cables and workers’ arms and hands

• Reliable locking mechanism provides consistent strength

and lasting performance

• Outside serrations on strap prevent pinching the 

cable jacket

• Five cross sections available including the new 

Heavy-Standard size

• All cable tie cross sections have a curved tip that is easier

to pick up from flat surfaces, allows faster initial threading
and speeds installation  

• Material: Nylon 6.6  (see Material Selection Guide for 

additional sizes, materials and colours available)

Part Number

Length

Width

Max. Bundle

Dia.

Min. Loop

Tensile Str.

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

M

mm

mm

N

TTS-20R0

6

19.1

Various

178

1

10

TTS-35RX0

11

19.1

Various

178

1

10

Part Number

Length 

Width 

Max.

Bundle Dia. 

Min. Loop

Tensile Str.

Tool

Bulk
Pkg.

Qty.

Bulk

Ctn.

Qty.

mm

mm

mm

N

Miniature Cross Section

CBR1M-M

104

2.5

25

80

GTS, GS2B, PTS, 

PPTS, STS2

1000 50000

CBR1.5M-M

142

2.5

38

80

1000 50000

CBR2M-M

183

2.5

51

80

1000 25000

Intermediate Cross Section

CBR1.5I-M

150

3.6

38

178

GTS, GS2B, PTS, 

PPTS, STS2

1000 25000

CBR3I-M

264

3.6

76

178

1000 10000

CBR4I-M

345

3.6

102

178

1000 10000

Standard Cross Section

CBR2S-M

193

4.8

51

222

GTS, GS2B, GTH,

GS4H, PTS, PPTS,

STS2, STH2

1000 10000

CBR3S-M

274

4.8

76

222

1000

5000

CBR4S-M

356

4.8

102

222

1000

5000

Heavy-Standard Cross Section

CBR2HS-D

203

6.4

51

378

GTH, GS4H, GS4EH,

STH2, ST2EH

500

5000

Light-Heavy Cross Section

CBR4LH-TL

371

7.6

102

534

GTH, GS4H, GS4EH,

PPTEH, STH2, ST2EH  

250

2500

CBR6LH-C

531

7.6

152

534

100

2000

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

324

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

B

ELT

-T

Y

In-Line Cable Tie

• Head design prevents protrusion of cut-off to protect 

adjacent cables and workers’ arms and hands

• Low profile head prevents snags and reduces overall 

bundle size

• Fully rounded edges on head and strap prevent sharp

edges from coming in contact with cable insulation

• Exclusively designed tip assures positive grip during

threading of tie

• All cable tie cross sections smaller than Light-Heavy have

a curved tip that is easier to pick up from flat surfaces,
allows faster initial threading and speeds installation  

• Material: Nylon 6.6  (see Material Selection Guide for 

additional sizes, materials and colours available)

Parallel-entry cable tie that threads like a belt (180° entry) 

Part Number

Length

Width

Max. Bundle

Dia.

Min. Loop

Tensile Str.

Tool

Bulk
Pkg.

Qty.

Bulk

Ctn.

Qty.

mm

mm

mm

N

Miniature Cross Section

ILT1M-M

122

2.5

28

80

GTS, GS2B, PTS, 

PPTS, STS2

1000 50000

Intermediate Cross Section

ILT1.5I-M

137

3.6

35

133

GTS, GS2B, PTS, 

PPTS, STS2

1000 25000

Standard Cross Section

ILT2S-M

211

4.8

48

222

GTS, GS2B, GTH, GS4H,

PTS, PPTS, STS2, STH2  

1000 10000

ILT3S-M

292

4.8

76

222

1000 5000

ILT4S-M

373

4.8

102

222

1000 5000

Light-Heavy Cross Section

ILT4LH-TL

376

7.6

102

534

GTH, GS4H, GS4EH,

PPTEH, STH2, ST2EH

250

2500

ILT6LH-C

538

7.6

152

534

100

2000

Panduit-Pannet-html.html
background image

325

• Versatile cable ties that can be used in 

countless applications

• One piece construction for consistent performance 

and reliability

• Tie bundle diameters up to (330mm) or join together 

for larger diameters

• All cable tie cross sections smaller than Light-Heavy have

a curved tip that is easier to pick up from flat surfaces,
allows faster initial threading and speeds installation

• High strength and low thread force
• Material: Nylon 6.6  (see Material Selection Guide for 

additional sizes, materials and colours available)

P

AN

-T

Y

Cable Ties

Part Number

Length

Width

Max. Bundle

Dia.

Min. Loop

Tensile Str.

Tool

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

N

Miniature Cross Section

PLT1M-C

99

2.5

22

80

GTS, GS2B, PTS, 

PPTS, STS2

100

1000

PLT1.5M-C

142

2.5

32

80

100

1000

PLT2M-C

203

2.5

51

80

100

1000

Intermediate Cross Section

PLT1.5I-C

142

3.6

35

178

GTS, GS2B, PTS, 

PPTS, STS2

100

1000

PLT2I-C

203

3.6

51

178

100

1000

PLT2.5I-C

246

3.7

64

178

100

1000

PLT3I-C

290

3.7

76

178

100

1000

PLT4I-C

368

3.7

102

178

100

1000

Standard Cross Section

PLT1S-C

122

4.8

25

222

GTS, GS2B, GTH, GS4H,

PTS, PPTS, STS2, STH2

100

1000

PLT1.5S-C

157

4.8

38

222

100

1000

PLT2S-C

188

4.8

48

222

100

1000

PLT2.5S-C

249

4.8

64

222

100

1000

PLT3S-C

292

4.8

76

222

100

1000

PLT4S-C

368

4.8

102

222

100

1000

PLT4.5S-C

394

4.8

114

222

100

1000

PLT5S-C

445

4.8

127

222

100

500

Light-Heavy Cross Section

PLT6LH-L

556

7.6

152

534

GTH, GS4H, GS4EH, PPTEH,

STH2, ST2EH

50

500

PLT7LH-L

627

7.6

178

534

50

500

PLT9LH-L

775

7.6

229

534

50

500

PLT10LH-L

871

7.6

262

534

50

1000

Heavy Cross Section

PLT2H-L

206

7.6

51

534

GTH, GS4H, GS4EH, PPTEH,

STH2, ST2EH  

50

500

PLT2.5H-L

251

7.6

64

534

50

500

PLT3H-L

290

7.6

76

534

50

500

PLT4H-L

368

7.6

102

534

50

500

PLT5H-L

450

8.9

127

778

50

500

PLT6H-L

530

8.9

152

778

50

500

PLT8H-L

779

8.9

229

778

50

500

PLT13H-Q

1100

8.9

330

778

25

500

Extra-Heavy Cross Section

PLT5EH-Q

511

12.7

127

1112

GS4EH, PPTEH, ST2EH

25

250

PLT6EH-Q

564

12.7

152

1112

25

250

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

326

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

-T

Y

Clamp Ties  

• Used to secure a wire bundle to another 

surface such as a control panel, wall 
or ceiling

• Design allows for bundling before or after

screwing clamp in place

• All cable tie cross sections have a curved tip

that is easier to pick up from flat surfaces,
allows faster initial threading and 
speeds installation

• Material: Nylon 6.6  (see Material Selection

Guide for additional sizes, materials and 
colours available)

P

AN

-T

Y

HALAR

s

Cable Ties

• Commonly accepted solution for bundling qualified cable

without conduit in air handling space applications

• Applications include nuclear plants, chemical 

environments, telecommunications equipment, aerospace,
and high and low temperature environments

• Low smoke density rating and an excellent flammability 

rating of UL94V-0

• Distinctive maroon colour identifies material

HALAR cable ties are UL Listed and UL Recognized as:  

Suitable For Use In Air Handling

Spaces per NEC, Section 300-22 (c) and (d)

s

HALAR is the registered trademark for Ausimont Inc. Fluoropolymer

Part Number

Length

Width

Max. Bundle

Dia.

Min. Loop

Tensile Str.

Tool

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

N

Miniature Cross Section

PLT1M-C702

102

2.5

22

80

GTS, GS2B, PTS, 

PPTS, STS2

100

1000

Standard Cross Section

PLT2S-C702

188

4.8

48

222

GTS, GS2B, GTH, GS4H,

PTS, PPTS, STS2, STH2

100

1000

PLT3S-C702

295

4.8

76

222

100

1000

Part Number

Length

Width

Max. Bundle

Dia.

Min. Loop

Tensile Str.

Metric
Screw

Size

Tool

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

N

Miniature Cross Section

PLC1M-S4-C

110

2.5

20

80

M2.5

GTS, GS2B, PTS, PPTS, STS2

100

1000

Intermediate Cross Section

PLC1.5I-S8-C

156

3.4

32

178

M4

GTS, GS2B, PTS, PPTS, STS2

100

1000

Standard Cross Section

PLC2S-S6-C

201

4.8

47

222

M3

GTS, GS2B, GTH, GS4H, PTS, 

PPTS, STS2, STH2

100

1000

PLC2S-S10-C

201

4.8

47

222

M5

100

1000

PLC3S-S10-C

305

4.8

76

222

M5

100

1000

PLC4S-S10-C

381

4.8

102

222

M5

100

1000

Heavy Cross Section

PLC2H-S25-L

228

7.6

51

534

M6

GTH, GS4H, GS4EH, PPTEH, STH2, ST2EH

50

500

PLC4H-S25-L

384

7.6

102

534

M6

50

500

Panduit-Pannet-html.html
background image

327

P

AN

-T

Y

Marker & Flag Cable Ties

• Used to fasten and identify bundles at

the same time

• May be marked with 

PANDUIT

Marker

Pens or Computer Printable Labels

• Custom imprinting with text, symbols or

trademarks available using 

PANDUIT

Custom Hot Stamping Service

• All cable tie cross sections have a

curved tip that is easier to pick up 
from flat surfaces, allows faster initial
threading and speeds installation 

• Material: Nylon 6.6  (see Material

Selection Guide for additional sizes,
materials and colours available)

HOT STAMPING

— 

Custom Printed Cable Ties

PANDUIT offers a custom service to suit your unique 
application requirements.  A wide variety of information 
can be imprinted on 

PANDUIT cable ties, marker ties and 

marker plates.

Printing is done utilising a durable “Hot Stamping” process 
that is an economical and convenient way to permanently 
mark cable ties.

Customize with a wide variety of choices:

• Seven basic text colours

• Special logos can be imprinted with camera-ready artwork

supplied by the customer

• Alphanumeric and sequential numbering for serialisation

• Minimum Order:  5,000 pcs. per Part Number / Message

Part Number

Length

Width

Max. Bundle

Dia.

Min. Loop

Tensile Str.

Write-On

Area

Tool

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

N

mm

Miniature Cross Section

PLF1M-C

109

2.5

22

80

7.9 x 19.1

GTS, GS2B, PTS, PPTS, STS2

100

1000

PLF1MA-C

130

2.5

22

80

19.1 x 26.4

100

1000

PLF1MB-C

101

2.5

19

80

7.9 x 23.4

100

1000

PLM1M-C

99

2.5

19

80

6.6 x 24.1

100

1000

PLM2M-C

203

2.5

51

80

6.6 x 24.1

100

1000

Standard Cross Section

PLM2S-C

188

4.7

45

222

11.1 x 22.1

GTS, GS2B, GTH, GS4H, PTS, PPTS,

STS2, STH2

100

1000

PLM4S-C

371

4.7

102

222

11.1 x 50.8

100

1000

PL2M2S-L

188

4.7

45

222

22.1 x 27.2

50

500

PL3M2S-L

188

4.7

45

222

22.1 x 45.5

50

500

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

328

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

D

OME

-T

OP

Barb Ty Clamp Cable Ties

• Used to secure a wire bundle to another 

surface such as a control panel, wall
or ceiling

• Design allows for bundling before or after

screwing clamp in place

• All cable tie cross sections smaller than 

Light-Heavy have a curved tip that is easier
to pick up from flat surfaces, allows faster 
initial threading and speeds installation  

• Material:  Nylon 6.6  (see Material Selection

Guide for additional sizes, materials and 
colours available)

D

OME

-T

OP

Barb Ty Cable Ties

D

OME

-T

OP

head features unique patented design with

round, smooth edges

• Stainless steel locking barb provides consistent 

performance, reliability and infinite adjustability through 
its entire bundle range

• High strength and low thread force

• All cable tie cross sections smaller than Light-Heavy have a

curved tip that is easier to pick up from flat surfaces, allows
faster initial threading and speeds installation

• Material: Nylon 6.6  (see Material Selection Guide for

additional sizes, materials and colours available)

Part Number

Length

Width

Max. Bundle

Dia.

Min. Loop

Tensile Str.

Tool

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

N

Miniature Cross Section

BT1M-C

102

2.4

23

80

GTS, GS2B, PTS, 

PPTS, STS2

100

1000

BT1.5M-C

160

2.4

38

80

100

1000

BT2M-C

201

2.4

51

80

100

1000

BT4M-C

361

2.4

102

80

100

1000

Intermediate Cross Section

BT1.5I-C

155

3.6

38

178

GTS, GS2B, PTS, 

PPTS, STS2

100

1000

BT2I-C

203

3.6

51

178

100

1000

BT3I-C

288

3.6

76

178

100

1000

BT4I-C

363

3.6

102

178

100

1000

Standard Cross Section

BT2S-C

203

4.7

51

222

GTS, GS2B, GTH, GS4H,

PTS, PPTS, STS2, STH2

100

1000

BT3S-C

305

4.7

76

222

100

1000

BT4S-C

384

4.7

102

222

100

1000

Light-Heavy Cross Section

BT2LH-L

221

7.0

51

534

GTH, GS4H, GS4EH, PPTEH,

STH2, ST2EH

50

500

BT3LH-L

300

7.0

76

534

50

500

BT4LH-L

378

7.0

102

534

50

500

BT6LH-L

538

7.0

152

534

50

500

BT7LH-L

620

7.0

178

534

50

500

BT8LH-L

699

7.0

203

534

50

500

BT9LH-L

780

7.0

229

534

50

500

Part Number

Length

Width

Max. Bundle

Dia.

Min. Loop

Tensile Str.

Metric
Screw

Size

Tool

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

N

Miniature Cross Section

BC1M-S4-M

117

2.4

23

80

M2.5

GTS, GS2B, PTS, PPTS, STS2

1000 50000

BC2M-S4-M

211

2.4

51

80

M2.5

1000 25000

Intermediate Cross Section

BC1.5I-S8-M

168

3.6

38

178

M4

GTS, GS2B, PTS, PPTS, STS2

1000 25000

Standard Cross Section

BC2S-S10-D

216

4.7

51

222

M5

GTS, GS2B, GTH, GS4H, PTS, 

PPTS, STS2, STH2  

500

10000

BC4S-S10-C

396

4.7

102

222

M5

100

1000

Light-Heavy Cross Section

BC4LH-S25-L

394

7.0

102

534

M6

GTH, GS4H, GS4EH, PPTEH, 

STH2, ST2EH

50

500

Panduit-Pannet-html.html
background image

329

D

URA

-T

Y

Cable Ties

• Ideal for all outdoor messenger strand applications 

including telephone, cable TV, traffic signals and 
outside plant power services

• Double stainless steel, type 302, locking barb
• High tensile strength and high impact resistance

• Excellent chemical and moisture resistance
• Meets Telcordia TR-TSY-000789
• May be used with Stackable Cable Spacer, SACS50-T100,

shown below (see page 330 for part information)

• Material:  Weather Resistant Acetal strap body and head

D

OME

-T

OP

Barb Ty Marker & Flag Ties

• Used to fasten and identify bundles at the same time
• May be marked with 

PANDUIT

Marker Pens or Computer

Printable Labels

• Custom imprinting with text, symbols or trademarks 

available using 

PANDUIT

Custom Hot Stamping Service

• All cable tie cross sections have a curved tip that is easier

to pick up from flat surfaces, allows faster initial threading
and speeds installation  

• Material:  Nylon 6.6  (see Material Selection Guide for 

additional sizes, materials and colours available)

Part Number

Length

Width

Max. Bundle

Dia.

Min. Loop

Tensile Str.

Write-On

Area

Tool

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

N

mm

Miniature Cross Section

BM1M-C

107

2.4

23

80

7.4 x 27.7

GTS, GS2B, PTS, PPTS, STS2

100

1000

BM2M-C

201

2.4

51

80

7.4 x 27.7

100

1000

BF1M-C

116

2.4

23

80

9.1 x 20.6

100

1000

BF2M-C

211

2.4

51

80

9.1 x 20.6

100

1000

Standard Cross Section

BM2S-C

203

4.7

51

222

12.4 x 23.1

GTS, GS2B, GTH, GS4H, PTS, PPTS,

STS2, STH2

100

1000

BM4S-C

384

4.7

102

222

12.7 x 54.1

100

1000

B2M2S-D

203

4.7

51

222

29.2 x 23.1

500

2500

B3M2S-TL

203

4.7

51

222

46.0 x 23.1

250

2500

B4M2S-TL

203

4.7

51

222

62.7 x 23.1

250

2500

Part Number

Length

Strap

Width

Max. Bundle

Dia.

Min. Loop

Tensile Str.

Tool

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

N

Extra-Heavy Cross Section

DT4EH-L0

343

12.7

98

1112

GTH, GS4EH, ST2EH

50

1000

DT8EH-Q0

686

12.7

203

1112

25

500

Part Number

Description

Length 

Strap

Width 

Min. Loop

Tensile Str. 

Tool

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

M

mm

N

Strapping, Heads and Kit

DTREH-LR0

50' reel of strapping

15

12.7

1112

GTH, GS4EH,

ST2EH

1

20

DTHEH-Q0

Bag of 25 cable tie heads

25

500

DTKEH-0

Kit containing 50' reel of
strapping and 25 cable tie
heads

15

12.7

1112

GTH, GS4EH,

ST2EH

1

20

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

330

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Stackable Cable Spacer

• Manufactured from Black Weather

Resistant Polypropylene

• For use with 

D

URA

-T

Y

Cable Ties (see

page 9) or 

P

AN

-S

TEEL

Metal Locking

Ties (see page 23)

• For indoor/outdoor use

• Each spacer snaps into another 

to increase spacer heights by 
1/2" increments

• Designed to be used in parallel and 

perpendicular applications

Ergonomic Cable Tie Installation Tools

• Lightweight, ergonomic design is 

comfortable to use and reduces 
operator fatigue

• Exceeds industry standards for tool 

operation to provide high reliability for
maximum tool life

• Narrow nose improves visibility and

access to bundles in confined areas

• Flush cut-off protects adjacent cables

and workers’ arms and hands

• Tension adjustment conveniently located

at the rear of the tool to help quickly and
easily change and confirm tension 
settings to improve installer productivity

PANDUIT

ergonomic cable tie installation tools reduce worker fatigue, increase

productivity and provide the lowest total installed cost. These tools automatically and
consistently control tension and cut-off of the cable tie during installation.

Part Number

Length

Width

Bulk
Pkg.

Qty.

Bulk

Ctn.

Qty.

mm

mm

SACS50-T100

52.8

29.5

200

2000

Part Number

Description

Std.

Pkg.

Qty.

GTS

Installs Subminiature, Miniature, Intermediate and Standard cross section
cable ties.  Qualified Product Listed per Mil. Std. MS90387-1 and Mil.
Spec. MIL-T-81306A.

Colour identification:  black trigger handle  
Body:  grey plastic housing with black selector knob 
Weight:  8.8 oz. (249g)

1

GTH

Installs Standard, Heavy-Standard, Light-Heavy and Heavy cross section
cable ties. 

Colour identification:  red trigger handle  
Body:  grey plastic housing with red selector knob 
Weight:  11.2 oz. (318g)

1

Panduit-Pannet-html.html
background image

331

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

PLT

Part Description

PLT

= Locking Tie

PRT

= Releasable Tie

PLC

= Locking Clamp

PLF

= Locking Flag

PLM

= Locking Marker

PANDUIT

Mil Spec

Material - Colour

Suffix*

Suffix**

Heat Stabilized Nylon 6.6 - Black . . . . . . . . . . .30  . . . . . . . .N/A
Heat Stabilized Nylon 6.6 - Natural  . . . . . . . . .39  . . . . . . . .N/A
Nylon 6.6 - Fluorescent Orange  . . . . . . . . . . . .53  . . . . . . . .N/A
Nylon 6.6 - Fluorescent Yellow . . . . . . . . . . . . .54  . . . . . . . .N/A
Nylon 6.6 - Fluorescent Green  . . . . . . . . . . . . .55  . . . . . . . .N/A
Nylon 6.6 - Fluorescent Pink  . . . . . . . . . . . . . .59  . . . . . . . .N/A
Flame Retardant Nylon 6.6 - Ivory  . . . . . . . . . .69  . . . . . . . .N/A
TEFZEL

n

- Aqua Blue  . . . . . . . . . . . . . . . . . . . .76  . . . . . . . .N/A

Weather Resistant Polypropylene - Black  . . .100  . . . . . . . .N/A
Natural Polypropylene - Green . . . . . . . . . . . .109  . . . . . . . .N/A
Nylon 12 - Black  . . . . . . . . . . . . . . . . . . . . . . .120  . . . . . . . .N/A
Heat Stabilized WR Nylon 6.6 - Black  . . . . . .300  . . . . . . . .N/A
HALAR

- Maroon  . . . . . . . . . . . . . . . . . . . . . .702  . . . . . . . .N/A

PANDUIT 

Mil Spec

Material - Colour

Suffix*

Suffix**

Nylon 6.6 - Natural (See Note)  . . . . . . . . . . . . .

3

 . . . . . . . . . .9

Weather Resistant Nylon 6.6 - Black  . . . . . . . . .0  . . . . . . . .N/A
WR Nylon 6.6 - Black (Meets Mil. Spec.) . . . . .00  . . . . . . . . . .0
Nylon 6.6 - Brown . . . . . . . . . . . . . . . . . . . . . . . .1  . . . . . . . . . .1
Nylon 6.6 - Red  . . . . . . . . . . . . . . . . . . . . . . . . .2  . . . . . . . . . .2
Nylon 6.6 - Orange . . . . . . . . . . . . . . . . . . . . . . .3  . . . . . . . . . .3
Nylon 6.6 - Yellow . . . . . . . . . . . . . . . . . . . . . . . .4  . . . . . . . . . .4
Nylon 6.6 - Green . . . . . . . . . . . . . . . . . . . . . . . .5  . . . . . . . . . .5
Nylon 6.6 - Blue  . . . . . . . . . . . . . . . . . . . . . . . . .6  . . . . . . . . . .6
Nylon 6.6 - Purple  . . . . . . . . . . . . . . . . . . . . . . .7  . . . . . . . . . .7
Nylon 6.6 - Grey  . . . . . . . . . . . . . . . . . . . . . . . . .8  . . . . . . . . . .8
Nylon 6.6 - White  . . . . . . . . . . . . . . . . . . . . . . .10  . . . . . . . .N/A
Nylon 6.6 - Telephone Grey  . . . . . . . . . . . . . . .14  . . . . . . . .N/A
Nylon 6.6 - Black  . . . . . . . . . . . . . . . . . . . . . . .20  . . . . . . . .N/A

Material / Colour Chart

Colour

See chart
below for 
colours and
materials
available

C

Package Size

=  25

L

=    50

C

= 100

TL

= 250

D

= 500

M

= 1000

S

Cross Section

SM = Subminiature
M

= Miniature

I

= Intermediate

S

= Standard

LH = Light-Heavy
H

= Heavy

EH = Extra-Heavy

2

Size

Approx.
Maximum
Bundle 
Dia. (In)

* Note:

3

denotes 

PANDUIT standard Natural Nylon 6.6 (no suffix required in part number)

** Note: Mil. Spec. colour suffix per SAE AS33671 and AS33681 (formerly MS3367 and MS3368)

P

AN

-T

Y

Cable Ties

Part Number System (Example of PLT2S-C)

Screw Hole Size

(Clamp Ties Only)
-S4 =   #4 (M2.5)
-S6 =   #6 (M3)
-S8 = #8 

(M4)

-S10 = #10 (M5)
-S25 =  1/4 (M6)

Part Number Availability List

Standard Packaging

Bulk Packaging

Part Number

Natural 

Nylon 6.6

Colour / Material Suffix

Part Number

Natural 

Nylon 6.6

Colour / Material Suffix

PLC1M-S4-C

3

0

PLC1M-S4-M

3

0,30

PLC1.5I-S8-C

3

0

PLC1.5I-S8-M

3

0,30

PLC2S-S6-C

3

0

PLC2S-S6-M

3

0

PLC2S-S10-C

3

0,14

PLC2S-S10-M

3

0,20,30

PLC3S-S10-C

3

0

PLC3S-S10-M

3

0

PLC4S-S10-C

3

0

PLC4S-S10-M

3

0,30

PLC2H-S25-L

3

PLC2H-S25-TL

3

0

PLC4H-S25-L

3

0

PLC4H-S25-TL

3

0,30

PLF1M-C

3

0

PLF1M-M

3

0,2,3,4,6,10,69

PLF1MA-C

3

3,4

PLF1MA-M

3

0,2,3,4,5,6,10

PLF1MB-C

3

PLF1MB-M

3

PLM1M-C

3

0

PLM1M-M

3

0,1,2,3,4,5,6,7,8,10,69

PLM2M-C

3

PLM2M-M

3

0,4,6

PLM2S-C

3

0

PLM2S-D

3

0,2,3,4,5,6,8

PLM4S-C

3

PLM4S-D

3

0,2,4,6

Panduit-Pannet-html.html
background image

332

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Colour / Material Suffix

Natural 

Nylon 6.6

Part Number

Colour / Material Suffix

Natural 

Nylon 6.6

Part Number

Bulk Packaging

Standard Packaging

PL2M2S-L

3

PL2M2S-D

3

0,4,10

PL3M2S-L

3

PL3M2S-D

3

0,4

PLP1.5I-C

3

PLP1.5I-M

3

0,30

PLP1S-M

3

0,30

PLP1.5S-M

3

PLP2S-C

3

PLP2S-M

3

0,30

PLT.6SM-C

3

0

PLT.6SM-M

3

0,30

PLT.7M-C

3

PLT.7M-M

3

0,30

PLT1M-C

3

0,00,1,2,3,4,5,6,7,8,10,14,30,
76,702

PLT1M-M

3

0,00,1,2,3,4,5,6,7,8,10,14,20,
30,53,54,55,59,69,76,100,109
,120,300,702

PLT1M-XMR

3

0,1,2,3,4,5,6,7,8,10,30

PLT1.5M-C

3

0

PLT1.5M-M

3

0,00,2,4,5,6,8,10,14,20,30

PLT1.5M-XMR

3

0,30

PLT2M-C

3

0

PLT2M-M

3

0,1,2,3,4,5,6,7,8,10,20,30,69

PLT1.5I-C

3

0,1,2,3,4,5,6,7,8,10,20,30

PLT1.5I-M

3

0,00,1,2,3,4,5,6,7,8,10,20,30,
69,100,109,120,300

PLT2I-C

3

0,14,30,76

PLT2I-M

3

0,00,1,2,3,4,5,6,7,8,10,14,20,
30,53,54,55,59,69,76,300

PLT2.5I-C

3

0

PLT2.5I-M

3

0,20

PLT3I-C

3

0,14

PLT3I-M

3

0,2,3,4,5,6,8,10,14,20,30

PLT4I-C

3

0,14

PLT4I-M

3

0,2,5,6,14,20,30

PLT1S-C

3

0

PLT1S-M

3

0,30,38,300

PLT1.5S-C

3

0

PLT1.5S-M

3

0,30

PLT2S-C

3

0,00,1,2,3,4,5,6,7,8,10,20,30,
76,102

PLT2S-M

3

0,00,1,2,3,4,5,6,7,8,10,20,30,
38,39,53,54,55,59,69,76,100,
109,120,300,702

PLT2.5S-C

3

0

PLT2.5S-M

3

0,30

PLT3S-C

3

0,00,2,30,76,702

PLT3S-M

3

0,00,1,2,3,4,5,6,7,8,10,20,30,
53,54,55,59,76,100,109,702

PLT4S-C

3

0,00,2,3,4,5,6,8,20,30,76

PLT4S-M

3

0,00,1,2,3,4,5,6,7,8,10,14,20,
30,69,76,100,109,120,300

PLT4.5S-C

3

0

PLT4.5S-M

3

0

PLT5S-C

3

0

PLT5S-M

3

0,2,3,4,5,6,8,30

PLT6LH-L

3

0

PLT6LH-C

3

0

PLT7LH-L

3

0

PLT7LH-C

3

0,30

PLT8LH-L

3

0

PLT8LH-C

3

0,120

PLT8LH-Q

0

PLT9LH-L

3

0

PLT9LH-C

3

0,30

PLT10LH-L

3

PLT10LH-C

3

PLT2H-L

3

0

PLT2H-TL

3

0,2,4,6,30,100,109,300

PLT2.5H-L

3

0

PLT2.5H-TL

3

0

PLT3H-L

3

0,76

PLT3H-TL

3

0,30,76,100,109

PLT4H-L

3

0,00,76

PLT4H-TL

3

0,00,2,3,4,5,6,10,20,30,69,76,
100,109,120,300

PLT4H-C

3

0

PLT5H-L

3

0

PLT5H-C

3

0,30

PLT6H-L

3

0

PLT6H-C

3

0,30

PLT8H-Q

0

PLT8H-C

3

0,00,30

PLT8H-L

3

0

PLT13H-Q

3

0

PLT13H-C

3

0,3

PLT2EH-Q

0

PLT2EH-C

3

0

PLT3EH-NB-C

0

PLT5EH-Q

3

0

PLT5EH-C

3

0

PLT5EH-NB-C

0

PLT6EH-Q

3

0

PLT6EH-C

3

0

PLT6EH-NB-C

0

PLT8EH-Q

0

PLT8EH-C

3

0

P

AN

-T

Y

Cable Ties (continued)

Part Number Availability List

Panduit-Pannet-html.html
background image

333

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

PANDUIT

Mil Spec

Material - Colour

Suffix*

Suffix**

Nylon 6.6 - Blue  . . . . . . . . . . . . . . . . . . . . . . . . .6  . . . . . . . . . .6
Nylon 6.6 - Purple  . . . . . . . . . . . . . . . . . . . . . . .7  . . . . . . . . . .7
Nylon 6.6 - Grey  . . . . . . . . . . . . . . . . . . . . . . . . .8  . . . . . . . . . .8
Nylon 6.6 - White  . . . . . . . . . . . . . . . . . . . . . . .10  . . . . . . . .N/A
Nylon 6.6 - Telephone Grey  . . . . . . . . . . . . . . .14  . . . . . . . .N/A
Nylon 6.6 - Black  . . . . . . . . . . . . . . . . . . . . . . .20  . . . . . . . .N/A
Heat Stabilized Nylon 6.6 - Black . . . . . . . . . . .30  . . . . . . . .N/A
Heat Stabilized Nylon 6.6 - Natural  . . . . . . . . .39  . . . . . . . .N/A

PANDUIT 

Mil Spec

Material - Colour

Suffix*

Suffix**

Nylon 6.6 - Natural (See Note)  . . . . . . . . . . . . .

3

 . . . . . . . . . .9

Weather Resistant Nylon 6.6 - Black  . . . . . . . . .0  . . . . . . . .N/A
Nylon 6.6 - Brown . . . . . . . . . . . . . . . . . . . . . . . .1  . . . . . . . . . .1
Nylon 6.6 - Red  . . . . . . . . . . . . . . . . . . . . . . . . .2  . . . . . . . . . .2
Nylon 6.6 - Orange . . . . . . . . . . . . . . . . . . . . . . .3  . . . . . . . . . .3
Nylon 6.6 - Yellow . . . . . . . . . . . . . . . . . . . . . . . .4  . . . . . . . . . .4
Nylon 6.6 - Green . . . . . . . . . . . . . . . . . . . . . . . .5  . . . . . . . . . .5

Material / Colour Chart

Colour

See chart
below for 
colours and
materials
available

C

Package Size

Q  =  25
L

=    50

C

= 100

TL = 250
D

= 500

M

= 1000

LR = 50’ Reel
0

=  DT Kit

M

Cross Section

M

= Miniature

I

= Intermediate

S

= Standard

LH

= Light-Heavy

EH

= Extra-Heavy

1

Size

Approx.
Maximum
Bundle 
Dia. (In)

BT

Part Description

BT

= Barb Ty

BC

= Barb Ty Clamp

BF

= Barb Ty Flag

BM

= Barb Ty Marker

DT

D

URA

-T

Y

D

OME

-T

OP

Barb Ty Cable Ties

Part Number System (Example of BT1M-C)

N/A = Not applicable to military specified parts

Screw Hole Size

(Clamp Ties Only)

-S4 = #4 (M2.5)
-S6 = #6 (M3)
-S8 = #8 (M4)
-S10= #10 (M5)
-S25= 1/4 (M6)

*  Note:

3

denotes 

PANDUIT standard Natural Nylon 6.6 (no suffix required in part number)

**Note:

Mil. Spec. colour suffix per SAE AS33671 and AS33681(formerly MS3367 and MS3368)

^ D

URA

-T

Y

Weather Resistant Acetal strap body and head

Standard Packaging

Bulk Packaging

Part Number

Natural 

Nylon 6.6

Colour / Material Suffix

Part Number

Natural 

Nylon 6.6

Colour / Material Suffix

BC1M-S4-M

3

0

BC2M-S4-M

3

0

BC1.5I-S8-M

3

0

BC2S-S10-C

3

0

BC2S-S10-D

3

0

BC3S-S10-D

3

0

BC4S-S10-C

3

0

BC4S-S10-D

3

0,30

BC4LH-S25-L

3

0

BC4LH-S25-TL

3

0

BF1M-C

3

BF1M-M

3

0

BF2M-C

3

BF2M-M

3

0

BM1M-C

3

BM1M-M

3

0

BM2M-C

3

BM2M-M

3

0

BM2S-C

3

BM2S-D

3

0

BM4S-C

3

BM4S-D

3

0

BT1M-C

3

0,30

BT1M-M

3

0,1,2,3,4,5,6,7,8,10,30,39

BT1.5M-C

3

0

BT1.5M-M

3

0,30

BT2M-C

3

0

BT2M-M

3

0,2,3,4,5,6,8,30

BT4M-C

3

0

BT4M-M

3

0

BT1.5I-C

3

0

BT1.5I-M

3

0,1,2,3,4,5,6,7,8,10,30,39

BT2I-C

3

0

BT2I-M

3

0,30

BT3I-C

3

0

BT3I-M

3

0,14,30

BT4I-C

3

0

BT4I-M

3

0,14

BT2S-C

3

0

BT2S-M

3

0,1,2,3,4,5,6,7,8,10,20,30,39

BT3S-C

3

0,2

BT3S-M

3

0,30,39

BT4S-C

3

0

BT4S-M

3

0,2,3,4,5,6,7,8,10,30,39

BT2LH-L

3

0

BT2LH-TL

3

0

BT3LH-L

3

0

BT3LH-TL

3

0

BT4LH-L

3

0

BT4LH-TL

3

0,30,39 

BT5LH-L

3

0

BT5LH-C

3

0

BT6LH-L

3

0

BT6LH-C

3

0

BT7LH-L

3

0

BT7LH-C

3

0

BT8LH-L

3

0

BT8LH-C

3

0

BT9LH-L

3

0

BT9LH-C

3

0

BW1.5I-D

3

BW2S-D

3

0

B2M2S-D

3

0

B3M2S-TL

3

0

B4M2S-TL

3

0

^DTHEH-Q

0

^DTKEH-0

0

^DTREH-LR

0

^DT4EH-L

0

^DT8EH-Q

0

Panduit-Pannet-html.html
background image

334

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Colour

See chart below for 
colours and materials
available

M

Package Size

C = 100
TL = 250
D = 500
M = 1000

M

Cross Section

M

= Miniature

I

= Intermediate

S

= Standard

HS = Heavy-Standard
LH = Light-Heavy

1

Size

Approx.
Maximum
Bundle 
Dia. (In)

ILT

Part Description

CBR = 

C

ONTOUR

-T

Y

ILT

B

ELT

-T

Y

In-Line Tie

PANDUIT

Mil Spec

Material - Colour

Suffix*

Suffix**

Nylon 6.6 - Natural (See Note)  . . . . . . . . . . . . .

3

 . . . . . . . . . .9

Weather Resistant Nylon 6.6 - Black  . . . . . . . . .0  . . . . . . . .N/A

*  Note:

3

denotes 

PANDUIT standard Natural Nylon 6.6 (no suffix required in part number)

**Note:

Mil. Spec. colour suffix per SAE AS33671 and AS33681(formerly MS3367 and MS3368)

Parallel Entry Cable Ties

Part Number System (Example of ILT1M-M)

Material / Colour Chart

Standard Packaging

Bulk Packaging

Part Number

Natural 

Nylon 6.6

Colour / Material Suffix

Part Number

Natural 

Nylon 6.6

Colour / Material Suffix

CBR1M-M

3

0

CBR1.5M-M

3

0

CBR2M-M

3

0

CBR1.5I-M

3

0

CBR3I-M

3

0

CBR4I-M

3

0

CBR2S-M

3

0

CBR3S-M

3

0

CBR4S-M

3

0

CBR2HS-D

3

0

CBR4LH-TL

3

0

CBR6LH-C

3

0

ILT1M-M

3

0

ILT1.5I-M

3

0

ILT2S-C

3

0

ILT2S-M

3

0

ILT3S-C

3

0

ILT3S-M

3

0

ILT4S-C

3

0

ILT4S-M

3

0

ILT4LH-TL

3

0

ILT6LH-C

3

0

Panduit-Pannet-html.html
background image

335

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

0

Colour

See chart
below for 
colours and
materials
available

X

Package Size

X = 

3048mm

15R

= 4572mm Roll

20R

= 6096mm Roll

35RX = 10668mm Roll
75R

= 22860mm Roll

S

Cross Section

I = Intermediate
S = Standard

3

Size

Approx.
Maximum
Bundle 
Dia. (In)

HLC

Part Description

HL

= Hook & Loop

HLC

= H & L Cinch Tie

HLT

= H & L Tie

HLTP

= H & L Tie Plenum

HLS

= H & L Strip

HLSP = H & L Strip Plenum
HLM

= H & L Roll Miniature

GCTC = Grommet Cinch Tie - Centre Mount
GCTE = Grommet Cinch Tie - End Mount
TTS

T

AK

-T

APE

Standard

Colour

Suffix

Black  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0
Red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Orange  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Yellow  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Green  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Colour

Suffix

Blue  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Grey  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
White  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Maroon  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Hook & Loop Cable Ties

Part Number System (Example of HLC3S-X0)

Material / Colour Chart

HLSP and HLTP are unique Hook & Loop style ties that are UL Listed for use in air handling spaces, per NEC, Section 300-22 (c)
and (d) and are UL94V-2 flame rated.  Available in Black (-X0) and Maroon (-X12)

Part Number Availability List

Standard Packaging

Part Number

Colour / Material Suffix

HLC3S-X

0

HLC5S-X

0

HLM-15R

0,2,3,4,5,6,8,10

HLS-15R

0,2,3,4,5,6,8,10

HLS-75R

0,2,3,4,5,6,8,10

HLS1.5S-X

0,2,3,4,5,6,8,10

HLS3S-X

0,2,3,4,5,6,8,10

HLS5S-X

0,2,3,4,5,6,8,10

HLT2I-X

0,2,3,4,5,6,8,10

HLT3I-X

0,2,3,4,5,6,8,10

HLSP1.5S-X

0,12

HLSP3S-X

0,12

HLSP5S-X

0,12

HLTP2I-X

0,12

HLTP3I-X

0,12

TTS-20R

0

TTS-35R

0

Panduit-Pannet-html.html
background image

336

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

T

AK

-T

Y

Hook & Loop Cable Tie Mounts

• For use with 

T

AK

-T

Y

Hook & Loop Cable Ties 

(see page 332)

• For indoor use only

• Dimensions are 27.9mm x 27.9mm x 8.6mm
• Unique cradle design provides maximum stability for 

cable bundle

4-Way Adhesive Backed Mounts

• Allows cable tie entry from all four sides
• Available in multiple sizes and colours to match 

application requirements

• Does not require secondary fastener
• Produced 2-up, 4-up, or with tear tabs for fast and easy

liner removal to speed installation

* Flame retardant products are manufactured from a material that is rated UL94V-0.

‡Cable Tie Cross Section Sizes:  M = Miniature, I = Intermediate, S = Standard, HS = Heavy-Standard, 
LH = Light-Heavy, H = Heavy, HLM = Miniature 

T

AK

-T

Y

Hook & Loop Ties.

Part Number

Material

Colour

Mounting

Method

Max. Static

Load

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

g

Adhesive Backed

ABMT-A-C

Nylon 6.6

Natural

Rubber

Adhesive

174

100 1000

ABMT-A-C20

Nylon 6.6

Black

174

100 1000

Screw Mount

ABMT-S6-C

Nylon 6.6

Natural

#6 (M3)

Screw

100 1000

ABMT-S6-C20

Nylon 6.6

Black

#6 (M3)

Screw

100 1000

ABMT-S6-C60

*

Flame Retardant 

Nylon 6.6

Black

#6 (M3)

Screw

100 1000

ABMT-S6-C69

*

Flame Retardant 

Nylon 6.6

Natural

#6 (M3)

Screw

100 1000

Part Number

Used With

Cable

Ties

Length

Width

Material

Colour

Max. Static

Load

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

g

Rubber Adhesive 

For indoor use only

ABM1M-A-C

M

12.7

12.7

Nylon 6.6

White

59

100

500

ABMM-A-C

M, I

19.1

19.1

ABS

White

136

100

500

ABM2S-A-C

M, I, S

25.4

25.4

ABS

White

227

100

500

ABM2S-A-C14

M, I, S

25.4

25.4

ABS

Grey

227

100

500

ABM2S-A-C15

M, I, S

25.4

25.4

ABS

Ivory

227

100

500

ABM100-A-C

M, I, S

25.4

25.4

Nylon 6.6

White

227

100 1000

ABM100-A-C15

M, I, S

25.4

25.4

Nylon 6.6

Ivory

227

100 1000

ABM3H-A-L

M, I, S,

HS, LH, 

H, & HLM

38.1

38.1

Nylon 6.6

White

508

50

500

ABM4H-A-L

M, I, S,

HS, LH, 

H, & HLM

50.8

50.8

Nylon 6.6

White

907

50

500

Acrylic Adhesive 

For indoor/outdoor and high temperature applications

ABM100-AT-C0

M, I, S

25.4

25.4

Weather

Resistant

Nylon 6.6

Black

227

100 1000

Panduit-Pannet-html.html
background image

337

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

• Manufactured from Natural Nylon 6.6
• For indoor use only

• Unique cradle design provides maximum stability for

cable bundle

• Installed with screw or rivet

Tie Mounts

• Manufactured from weather resistant black material
• For use with 

PANDUIT

Extra-Heavy Cross Section Ties

(see page 325) and HLM/HLT style 

T

AK

-T

Y

Hook &

Loop Cable Ties (see page 322)

• For indoor/outdoor use

• Dimensions are 42.0mm x 19.0mm x 15.0mm
• Unique cradle design provides maximum stability for 

cable bundle

Extra-Heavy Tie Mounts

• Manufactured from Natural Nylon 6.6
• For indoor use only

• Mounting Method:  Push Barb
• Use in pre-drilled 6.4mm holes with a maximum panel

thickness of 2.7mm

Winged Push Mount

‡Cable Tie Cross Section Sizes: M = Miniature, I = Intermediate, S = Standard, HS = Heavy Standard, 
LH = Light-Heavy.

‡Cable Tie Cross Section Sizes: M = Miniature, I = Intermediate, S = Standard.

Part Number

Used With Cable

Ties

Length

Width

Height

Mounting

Method

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

TM1S4-C

M

13.0

8.0

5.8

#4 (M2.5)

Screw

100

500

TM1S6-C

M

13.0

8.0

5.8

#6 (M3)

Screw

100

500

TM2S6-C

M, I, S

16.1

10.8

7.0

#6 (M3)

Screw

100

500

TM2S8-C

M, I, S

16.1

10.8

7.0

#8 (M4)

Screw

100

500

TM3S8-C

M, I, S, LH

22.2

15.8

9.5

#8 (M4)

Screw

100

500

TM3S10-C

M, I, S, LH

22.2

15.8

9.5

#10 (M5)

Screw

100

500

TM3S25-C

M, I, S, LH

22.2

15.8

9.5

1/4 (M6)

Screw

100

500

Part Number

Material

Mounting Method

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

TMEH-S8-Q0

Weather Resistant Nylon 6.6

#8 (M4) Screw

25

250

TMEH-S10-Q0

Weather Resistant Nylon 6.6

#10 (M5) Screw

25

250

TMEH-S25-Q0

Weather Resistant Nylon 6.6

1/4 (M6) Screw

25

250

TMEH-S10-C100

Weather Resistant Polypropylene

#10 (M5) Screw

100

500

Part Number

Used With Cable Ties

Length

Width

Height

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

PWMS-H25-C

M, I, S

19.1

9.4

15.5

100

1000

Panduit-Pannet-html.html
background image

338

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

JMJH2W-X20

JMJH2-X20

JMCB-X

JMCMB25-1-X

JMCMB25-3-X

• Modular design allows flexibility to assemble system in

multiple configurations

• Unique chaining bracket design creates a strong metal

backbone and allows expansion of the system without
disturbance of an existing installation

• Brackets allow for attachment to ceilings, beams, threaded

rods, and drop wires to meet requirements of a variety 
of applications

• Manufactured from materials that meet UL 2043 and are

suitable for use in air handling spaces

• Complete horizontal and vertical bend radius control
• Cables do not come in contact with metal

J-M

OD

Cable Support System

** Not for use with chaining brackets.
* Suitable for use in air handling spaces per UL 2043.

Part Number

Part Description

Material

*

Max. Static

Load

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Kg.

J Hook with maximum 50.8mm bundle capacity

JMJH2W-X20

J Hook for wall mount applications only.
Two 1/4" (M6) mounting holes for user
supplied screws.

Nylon

13.61

10

50

JMJH2-X20

J Hook with snap lock attachments for
use with all brackets listed below.

Nylon

13.61

10

50

Chaining Bracket

JMCB-X

Chaining bracket to extend 

J-Mod

capacity one level.  Capacity: 3 levels
maximum.  For use with all single-level
mounting brackets listed below.

Galvanized

Steel

54.45

10

50

Ceiling Mount Brackets

JMCMB25-1-X

Single-level ceiling mount bracket with
one 6.35mm (M6) mounting hole.

Galvanized

Steel

81.65

10

50

JMCMB25-3-X

**

Three-level ceiling mount bracket with
one 6.35mm (M6) mounting hole.
Maximum capacity of 6 J Hooks.

Galvanized

Steel

81.65

10

50

Panduit-Pannet-html.html
background image

339

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

J-M

OD

Cable Support System (continued)

JMDWB-1-X

JMDWB-3-X

JMTRB38-1-X

JMTRB38-3-X

JMSBCB87-1-X

JMSBCB87-3-X

** Not for use with chaining brackets.
* Suitable for use in air handling spaces per UL 2043.

Kg.

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.

Max. Static

Load

Material

*

Part Description

Part Number

Drop Wire Brackets

JMDWB-1-X

Single-level drop wire bracket.
Attaches to #12 wire or 6.35mm plain
rod. Maximum capacity of 1 J Hook 
per level.

Galvanized

Steel

9.07

10

50

JMDWB-3-X

**

Three-level drop wire bracket.
Attaches to #12 wire or 6.35mm 
plain rod. Maximum capacity of 1 J
Hook for each of 3 levels.

Galvanized

Steel

18.14

10

50

Threaded Rod Brackets

JMTRB38-1-X

Single-level threaded rod bracket.
Accepts 6.35mm – 9.5mm 
threaded rod.

Galvanized

Steel

81.65

10

50

JMTRB38-3-X

**

Three-level threaded rod bracket.
Accepts 6.35mm – 9.5mm threaded
rod. Maximum capacity of 6 J Hooks.

Galvanized

Steel

81.65

10

50

Screw-On Beam Clamp Brackets

JMSBCB87-1-X

Single-level screw-on beam clamp
bracket for use with flanges up to 
22.2mm thick.

Galvanized

Steel

81.65

10

50

JMSBCB87-3-X

** Three-level screw-on beam clamp

bracket for use with flanges up to
22.2mm thick.  Maximum capacity of 6
J Hooks.

Galvanized

Steel

81.65

10

50

Panduit-Pannet-html.html
background image

340

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Adhesive Backed Cord Clips

• Manufactured from Natural Nylon 6.6
• For indoor use only

• Mounting Method:  Rubber Adhesive
• Cables are easily snapped into or out of the clips

Bevel Entry Clips

• Manufactured from Natural Nylon 6.6
• For indoor use only
• Mounting Method:  Rubber Adhesive

• Three sizes to hold cable or cable bundles
• Beveled entry makes it easy to insert cable bundle

• Manufactured from TELCO Grey Polypropylene
• For indoor use only
• Dimensions are 25.4mm x 25.4mm

• Bundle Range: 4.8mm – 17.5mm diameter
• Adjustable clamp designed to contain various cable 

bundle diameters

C

LINCHER

Adjustable Releasable Clamp

Cable Bundle Strap

• For indoor use only
• Mounting Method: M6 Screw
• Dimensions are 122.6mm x 25.4mm x 64.5mm

• Bundle Range: Up to 38.7cm2
• Rounded edges prevent damage to cable jackets

* Flame retardant products are manufactured from a material that is rated UL94V-0.

Part Number

Max. Bundle

Dia.

Length

Width

Max. Static

Load

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

g

ACC19-A-C

4.8

16.0

19.3

91

100

500

ACC38-A-C

9.6

25.4

25.4

227

100

500

ACC62-A-C

15.7

31.7

28.6

318

100

500

Part Number

Mounting Method

Max. Static Load

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

g

ARC.68-A-Q14

Rubber Adhesive

227

25

250

ARC.68-S6-Q14

#6 (M3) Screw

25

250

Part Number

Max. Bundle

Dia.

Length

Width

Max. Static

Load

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

g

BEC38-A-L

9.6

37.1

31.5

411

50

500

BEC62-A-L

15.7

37.1

31.5

411

50

500

BEC75-A-L

19.0

37.1

37.8

493

50

500

Part Number

Material

Colour

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

WBS6-Q

ABS

Natural

25

125

WBS6-Q60 *

Flame Retardant Nylon 6.6

Black

25

125

Panduit-Pannet-html.html
background image

341

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Latching Clips

• Manufactured from Nylon 6.6
• For indoor use only
• Secures cords and cables

• Adhesive products have a large mounting base for high

bonding strength

• Available in 6 sizes with releasable latch

Cable Holder

• Manufactured from TELCO Grey Nylon 6.6
• For indoor use only
• Dimensions are 63.5mm x 26.0mm x 15.9mm
• Bundle Range: Up to 52.3mm x 9.9mm

• Low profile design holds cords and cables
• Convenient releasable latch allows easy addition and

removal of cables

• Adhesive product has a large mounting base for high 

bonding strength

* Mounting Method:  Rubber Adhesive.
** Push mount products require 6.4mm diameter hole in panels up to 2.7mm thick.

Part Number

Max. Bundle

Dia.

Length

Width

Colour

Max. Static

Load

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

mm

g

Adhesive Backed*

LWC19-A-C

4.8

21.6

15.5

Natural  

113

100 1000

LWC19-A-C14

4.8

21.6

15.5

Grey

113

100 1000

LWC25-A-C

6.4

22.2

25.4

Natural  

204

100 1000

LWC25-A-C14

6.4

22.2

25.4

Grey

204

100 1000

LWC38-A-C

9.6

25.4

25.4

Natural  

227

100 1000

LWC38-A-C14

9.6

25.4

25.4

Grey

227

100 1000

LWC50-A-L

12.7

32.0

25.4

Natural  

272

50

500

LWC50-A-L14

12.7

32.0

25.4

Grey

272

50

500

LWC75-A-L

19.1

37.6

31.5

Natural  

417

50

500

LWC75-A-L14

19.1

37.6

31.5

Grey

417

50

500

LWC100-A-L

25.4

56.1

50.0

Natural  

1020

50

500

LWC100-A-L14

25.4

56.1

50.0

Grey

1020

50

500

Push Mount**

LWC19-H25-C

4.8

21.6

12.8

Natural   

100 1000

LWC19-H25-C14

4.8

21.6

12.8

Grey

100 1000

LWC25-H25-C

6.4

21.8

14.7

Natural   

100 1000

LWC25-H25-C14

6.4

21.8

14.7

Grey

100 1000

LWC38-H25-C

9.6

23.9

14.7

Natural   

100 1000

LWC38-H25-C14

9.6

23.9

14.7

Grey

100 1000

LWC50-H25-L

12.7

31.8

19.3

Natural   

50

500

LWC50-H25-L14

12.7

31.8

19.3

Grey

50

500

LWC75-H25-L

19.1

36.8

22.1

Natural   

50

500

LWC75-H25-L14

19.1

36.8

22.1

Grey

50

500

LWC100-H25-L

25.4

48.0

25.4

Natural   

50

500

LWC100-H25-L14

25.4

48.0

25.4

Grey

50

500

Part Number

Mounting Method

Max. Static Load

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

g

CH105-A-C14

Adhesive Backed

581

100 1000

CH105-S6-C14

#6 (M3) Screw

100 1000

Panduit-Pannet-html.html
background image

342

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Part Number

Max.

Bundle Dia. 

Length 

Min. Loop

Tensile Str. 

Min. Bundle

Diameter 

Width

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

N

mm

mm

AISI 304 Stainless Steel 

For General Purpose

Standard Cross Section

MLT1S-CP

25

127

890

12.7

4.6

100

500

MLT2S-CP

51

201

100

500

MLT2.7S-CP

69

259

100

500

MLT4S-CP

102

362

100

500

MLT6S-CP

152

521

100

500

MLT8S-CP

203

679

100

500

NEW! Light-Heavy Cross Section

MLT2LH-LP

51

201

1112

12.7

6.4

50

250

MLT4LH-LP

102

362

50

250

MLT6LH-LP

152

521

50

250

MLT8LH-LP

203

679

50

250

Heavy Cross Section

MLT2H-LP

51

201

2000

12.7

7.9

50

250

MLT4H-LP

102

362

50

250

MLT6H-LP

152

521

50

250

MLT8H-LP

203

679

50

250

AISI 316 Stainless Steel

For Superior Corrosion Resistance

Standard Cross Section

MLT1S-CP316

25

127

890

12.7

4.6

100

500

MLT2S-CP316

51

201

100

500

MLT4S-CP316

102

362

100

500

MLT6S-CP316

152

521

100

500

MLT8S-CP316

203

679

100

500

NEW! Light-Heavy Cross Section

MLT2LH-LP316

51

201

1112

12.7

6.4

50

250

MLT4LH-LP316

102

362

50

250

MLT6LH-LP316

152

521

12.7

50

250

MLT8LH-LP316

203

679

50

250

Heavy Cross Section

MLT2H-LP316

51

201

2000

12.7

7.9

50

250

MLT4H-LP316

102

362

50

250

MLT6H-LP316

152

521

50

250

MLT8H-LP316

203

679

50

250

P

AN

-S

TEEL

Self-Locking Stainless Steel Cable Ties

• Strong, durable method of bundling and fastening
• Can be used in virtually all indoor, outdoor and 

underground (including direct burial) applications

• Well suited for network bundling of data and power cables

• Fully rounded edges and exclusive lead-in design
• Provides ultimate support for network cables

Product Specifications

• Material: Type 304 or 316

stainless steel

• Temperature range: -112°F 

(-80°C) to 1000°F (538°C)

• Water absorption:  none
• Flammability: non-flammable
• Ultraviolet resistance:

excellent

• Chemical resistance: excellent
• Radiation resistance:  

2 x 108 rads

• Loop tensile strength range:

890-2000N 
(see chart for sizes)

• Fully rounded edges and

smooth surfaces

• Estimated outdoor service life

of 40 years

MLT general purpose tie

available in three cross

sections

Panduit-Pannet-html.html
background image

343

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Part Number

Max.

Bundle Dia. 

Length

Min. Loop

Tensile Str. 

Min. Bundle

Diameter 

Width 

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

N

mm

mm

AISI 304 Stainless Steel 

For Superior Grip on Rigid Bundles

NEW! Standard Cross Section

MLT2.7WS-LP

69

259

890

51

4.6

50

250

MLT4WS-LP

102

362

50

250

MLT6WS-LP

152

521

50

250

MLT8WS-LP

203

679

50

250

NEW! Light-Heavy Cross Section

MLT2.7WLH-LP

69

259

1112

51

6.4

50

250

MLT4WLH-LP

102

362

50

250

MLT6WLH-LP

152

521

50

250

MLT8WLH-LP

203

679

50

250

Heavy Cross Section

MLT2.7WH-LP

69

259

2000

51

7.9

50

250

MLT4WH-LP

102

362

50

250

MLT6WH-LP

152

521

50

250

MLT8WH-LP

203

679

50

250

AISI 316 Stainless Steel - For Superior Grip on Rigid Bundles

NEW! Standard Cross Section

MLT2.7WS-LP316

69

259

890

51

4.6

50

250

MLT4WS-LP316

102

362

50

250

MLT6WS-LP316

152

521

50

250

MLT8WS-LP316

203

679

50

250

NEW! Light-Heavy Cross Section

MLT2.7WLH-LP316

69

259

1112

51

6.4

50

250

MLT4WLH-LP316

102

362

50

250

MLT6WLH-LP316

152

521

50

250

MLT8WLH-LP316

203

679

50

250

Heavy Cross Section

MLT2.7WH-LP316

69

259

2000

51

7.9

50

250

MLT4WH-LP316

102

362

50

250

MLT6WH-LP316

152

521

50

250

MLT8WH-LP316

203

679

50

250

P

AN

-S

TEEL

W

AVE

-T

Y

Self-Locking Stainless Steel Cable Ties

• Patented wave-form spring maintains greater installed 

tension on non-resilient objects

• Loop tensile strength of 890-2000 N provides superior

strength for increased performance and reliability on most
bundling applications

W

AVE

-T

Y

Stainless Steel Tie 

for superior grip

GS4MT Installation tool

Panduit-Pannet-html.html
background image

344

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Patented Nylon 11 Selectively Coated Ties

• For communication and electrical cables

• Strength of steel, the protection of nylon; the nylon coating

provides protection for the cables

Optional Installation Tooling

• Complete line of manual and pneumatic installation tools

speed installation

• Side entry of cable ties into the tools means quick and

easy installation

• Automatic tension and cut-off capabilities available on

select models

• High reliability, low maintenance, long life

Tool

MLT Cross Section

MLT Usage

per Year

Operation

GS4MT

Standard, Light

Heavy, Heavy

Under 50,000

Hand; tool controlled tension and cut-off

PPTMT

Standard, Light

Heavy, Heavy

Over 50,000

Pneumatic; tool controlled tension 

and cut-off

ST2MT

Standard, Light

Heavy, Heavy

Under 10,000

Hand; manual controlled tension

twist cut-off

HTMT

Standard, Light

Heavy, Heavy

Under 10,000

Hand; manual controlled tension no cut-off

Part Number

Max.

Bundle Dia.

Length

Min. Loop

Tensile Str. 

Min. Bundle

Diameter 

Width 

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

N

mm

mm

MLTC2H-LP316

51

201

1112

12.7

7.9

50

250

MLTC4H-LP316

102

362

50

250

MLTC6H-LP316

152

521

50

250

MLTC8H-LP316

203

679

50

250

Panduit-Pannet-html.html
background image

345

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

P

AN

-W

RAP

Split Harness Wrap

• Patent pending slot pattern provides improved flexibility

and abrasion protection in any application

• Large overlap accommodates a wide range of 

bundle diameters

• Unique wall design provides for easy cable breakouts

• Innovative design maintains uniform bundle protection in

dynamic applications

• Packaged on a reel for easy handling and dispensing 

of product

Spiral Wrap

• Bundle Range: 9.5mm – 101.6mm
• Allows breakouts of single/multiple cables
• Harness multiple cables into a single manageable bundle
• Provides protection for cables
• Colour code cable bundles 

• Reusable
• Installation tool supplied in each package
• Packaged on a 30.5M reel for easy handling and 

dispensing of product

* Order number of reels required.
** Flame retardant products are manufactured from a material that is rated UL94V-0.
Contact Customer Service for additional sizes and materials available.

P

AN

-W

RAP

Installation Tool

• Patent pending installation tool with 180° opening allows

easy loading of maximum bundle diameters to speed
installation, providing the lowest installed cost

** Order number of tools required.

‡ Diameter can be further reduced with the use of cable ties.
* Order number of reels required.

Part Number

Nominal

I.D.

Min.

Bundle

Dia.

Max.

Bundle

Dia.

Material

Colour

Length Per

Reel

Std.

Pkg.

Qty.*

mm

mm

mm

M

PW50F-T

12.7

10.9

14.0

Polyethylene

Natural

61.1

1

PW75F-C

19.1

14.0

20.6

Polyethylene

Natural

30.5

1

PW50F-T20

12.7

10.9

14.0

Polyethylene

Black

61.1

1

PW75F-C20

19.1

14.0

20.6

Polyethylene

Black

30.5

1

Part Number

Colour

For Use With

Std. Pkg.

Qty.

**

PWT50

White

PW50F

1

PWT75

White

PW75F

1

PWT100

White

PW100F

1

PWT150

White

PW150F

1

Part Number

Material

Colour

Std.

Pkg.

Qty.*

T50F-C

Polyethylene

Natural

1

T50F-C0

Weather Resistant Polyethylene

Black

1

T50F-C1

Polyethylene

Brown

1

T50F-C2

Polyethylene

Red

1

T50F-C3

Polyethylene

Orange

1

T50F-C4

Polyethylene

Yellow

1

T50F-C5

Polyethylene

Green

1

T50F-C6

Polyethylene

Blue

1

T50F-C7

Polyethylene

Purple

1

T50F-C8

Polyethylene

Grey

1

T50F-C10

Polyethylene

White

1

T50F-C16

Polyethylene

Pink

1

T50FR-C **

Flame Retardant Polyethylene 

Natural

1

T50FR-C20 **

Flame Retardant Polyethylene 

Black

1

Panduit-Pannet-html.html
background image

346

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Corrugated Loom Tubing

• Manufactured from Polyethylene
• For indoor use only
• Protects and reduces the risk of damage to cabling

• Packaged on a reel for easy handling and dispensing 

of product

* Order number of reels required.
Contact Customer Service for additional sizes, materials, colours and bulk packaging.

Part Number

Colour

Inside

Diameter

Outside

Diameter

Length Per

Reel

Std.

Pkg.
Qty*

mm

mm

M

Corrugated Loom Tubing 

Slit Wall

CLT25F-C3

Orange

6.7

9.9

30.5

1

CLT38F-C3

Orange

10.5

14.2

30.5

1

CLT50F-C3

Orange

12.8

17.0

30.5

1

CLT75F-C3

Orange

19.3

23.7

30.5

1

CLT100F-C3

Orange

23.2

27.7

30.5

1

CLT125F-L3

Orange

32.8

38.1

15.2

1

CLT150F-X3

Orange

39.1

47.2

3.0

1

CLT188F-X3

Orange

47.8

55.1

3.0

1

CLT25F-C20

Black

6.7

9.9

30.5

1

CLT38F-C20

Black

10.5

14.2

30.5

1

CLT50F-C20

Black

12.8

17.0

30.5

1

CLT75F-C20

Black

19.3

23.8

30.5

1

CLT100F-C20

Black

23.2

27.7

30.5

1

CLT125F-L20

Black

32.8

38.1

15.2

1

CLT150F-T20

Black

39.1

47.2

61.0

1

CLT150F-X20

Black

39.1

47.2

3.0

1

CLT150F-X4

Yellow

39.1

47.2

3.0

1

CLT188F-X4

Yellow

47.8

55.1

3.0

1

Corrugated Loom Tubing 

Solid Wall

CLTS25F-C3

Orange

6.7

9.9

30.5

1

CLTS38F-C3

Orange

10.5

14.1

30.5

1

CLTS50F-C3

Orange

12.8

17.0

30.5

1

CLTS75F-C3

Orange

19.3

23.7

30.5

1

CLTS100F-C3

Orange

23.2

27.7

30.5

1

CLTS125F-L3

Orange

32.8

38.1

15.2

1

CLTS25F-C

Black

6.7

9.9

30.5

1

CLTS38F-C

Black

10.5

14.1

30.5

1

CLTS50F-C

Black

12.8

17.0

30.5

1

CLTS75F-C

Black

19.3

23.7

30.5

1

CLTS100F-C

Black

23.2

27.7

30.5

1

CLTS125F-L

Black

32.8

38.1

15.2

1

Panduit-Pannet-html.html
background image

347

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Grommet Edging

• Use slotted wall product on irregularly shaped 

and round panel holes

• Use solid wall product on straight panels
• Adhesive ensures product stays in place

• Provided in 0.8mm thick material making it 

highly flexible

• General purpose material for use up to 50°C
• Packaged on a 30.5M reel for easy handling 

and dispensing of product

• Manufactured from Black Cross-Linked Polyolefin
• Adhesive lined inner wall seals and provides excellent 

protection against moisture

• Shrink ratio of 3:1

• Temperature range of -55°C to 105°C
• Voltage rating of 600V

HSEC Thick Wall End Caps

* Order the number of reels required.
** Flame retardant products are manufactured from a material that is rated UL94V-0.

Part Number

Width

Height

Material

Colour

Panel Thickness

Range

Std.

Pkg.

Qty.*

mm

mm

mm

Adhesive Lined Grommet Edging 

Slotted Wall

GEE62F-A-C

3.3

4.1

Polyethylene

Natural

.9 – 1.6

1

GEE62F-A-C0

3.3

4.1

Weather Resistant Polyethylene

Black

.9 – 1.6

1

GEE99F-A-C

4.3

4.7

Polyethylene

Natural

1.6 – 2.5

1

GEE99F-A-C0

4.3

4.7

Weather Resistant Polyethylene

Black

1.6 – 2.5

1

GEE144F-A-C

5.4

5.6

Polyethylene

Natural

2.5 – 3.7

1

GEE144F-A-C0

5.4

5.6

Weather Resistant Polyethylene

Black

2.5 – 3.7

1

Adhesive Lined Grommet Edging 

Solid Wall

GES62F-A-C

3.3

4.1

Polyethylene

Natural

.9 – 1.6

1

GES62F-A-C0

3.3

4.1

Weather Resistant Polyethylene

Black

.9 – 1.6

1

GES99F-A-C

4.3

4.7

Polyethylene

Natural

1.6 – 2.5

1

GES99F-A-C0

4.3

4.7

Weather Resistant Polyethylene

Black

1.6 – 2.5

1

GES144F-A-C

5.4

5.6

Polyethylene

Natural

2.5 – 3.7

1

GES144F-A-C0

5.4

5.6

Weather Resistant Polyethylene

Black

2.5 – 3.7

1

Flame Retardant Grommet Edging 

Slotted Wall**

GEE36FR-C

2.7

3.0

Polyethylene

Natural

.7 – .9

1

GEE62FR-C

3.3

4.1

.9 – 1.6

1

GEE99FR-C

4.3

3.9

1.6 – 2.5

1

GEE144FR-C

5.4

5.9

2.5 – 3.7

1

Flame Retardant Grommet Edging 

Solid Wall**

GES36FR-C

2.7

3.0

Polyethylene

Natural

.7 – .9

1

GES62FR-C

3.3

4.1

.9 – 1.6

1

GES99FR-C

4.3

3.9

1.6 – 2.5

1

GES144FR-C

5.4

5.9

2.5 – 3.7

1

Part Number

Min. Expanded

I.D.

Max. Recovered

I.D.

Copper Conductor Size Range

Cap

Length

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

mm

mm

AWG / kcmil

mm2

mm

HSEC0.5-X

11.9

4.6

#8 - #4 AWG

10 to 25

35.1

10

100

HSEC0.8-X

20.1

7.6

#4 - #3/0 AWG

25 to 95

54.1

10

100

HSEC1.0-X

25.9

11.4

#2 - #4/0 AWG

35 to 95

82.0

10

100

HSEC1.5-5

40.1

17.3

#250 - #500 MCM

120 to 240

98.0

5

50

HSEC2.0-5

57.2

22.1

#600 - #1000

MCM

300 to 500

140.2

5

50

HSEC4.0-2

105.2

45.2

#1500 - #2000

MCM

720 to 1000

175.3

2

10

Panduit-Pannet-html.html
background image

348

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

HSTTV Heat Shrink

• Manufactured from Flame Retardant Black 

Cross-Linked Polyolefin

• 6"L (152.4mm) pieces
• For dry locations
• Fast shrink time

• Shrink ratio of  2:1
• Temperature range of -67°F to 257°F (-55°C to 125°C)
• Voltage of 600V
• UL VW-1 Recognized, CSA Certified
• Mil Spec AMS-DTL-23053/5 Class 3

Maximum UL Temperature Range is 125°C.
Contact Customer Service for additional sizes and materials available.

Part Number

Nominal

Diameter /

Size

Min. Expanded I.D.

Max. Recovered

I.D.

Std. Pkg.

Qty.

(pieces)

Std. Ctn.

Qty.

(packages)

mm

mm

HSTTV05-Y

1.2mm

1.3

.5

26

10

HSTTV06-Y

1.6mm

1.5

.8

26

10

HSTTV09-Y

2.4mm

2.3

1.3

24

10

HSTTV12-Y

3.2mm

3.3

1.5

20

10

HSTTV19-Y

4.8mm

4.8

2.3

18

10

HSTTV25-Y

6.4mm

6.4

3.3

14

10

HSTTV38-Y

9.5mm

9.7

4.8

12

10

HSTTV50-Y

12.7mm

12.7

6.4

10

10

HSTTV75-Y

19.0mm

19.1

9.7

8

10

HSTTV100-Y

25.4mm

25.4

12.7

6

10

Panduit-Pannet-html.html
background image

349

L

ABELLING AND

A

DMINISTRATION

A world leader in network connectivity identification solutions,

PANDUIT

designs and 

manufactures labelling products, software and printers to assist you with TIA/EIA-606-A

compliance. For recommended product information and labelling solutions, please refer to

the following sections in this catalogue: Fibre Connectors, Enclosures & Patch Cords,

Modules, Patch Panels and Copper Patchcords & Punchdown.

PANDUIT

Network Connectivity Identification Solutions include a full line of TIA/EIA-606-A

standard compliant labelling products. Properly identifying your network allows moves, adds,

changes, trouble shooting and repairs to be accomplished faster and more efficiently. For detailed

information on 

PANDUIT

Identification Products, please visit www.panduit.com/emea.

The TIA/EIA-606-A standard states:

Size, colour and contrast of all labels should be
selected to ensure that the identifiers are easily read

Labels should be visible during the installation of
and normal maintenance of the infrastucture

Labels should be resistant to the environmental
conditions at the point of installation (such as
moisture or heat) and should have a design 
life equal to or greater than that of the 
labeled component

To maximise legibility, all labels shall be printed or
generated by a mechanical device

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Panduit-Pannet-html.html
background image

350

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P

AN

T

HER

LS8 Hand-Held Thermal Transfer Printer and Accessories

LS8

LS8-KIT

• Compact, rugged design includes reverse feeding and advanced

cut-to-length capability in order to minimise label waste 

• Includes large backlit display, adjustable cutter and USB interface

• 203 dpi thermal transfer printer creates crisp, clear legends with

superior legibility

• Used to print a wide variety of wire and cable labels, component

labels and continuous tapes up to 25.4mm wide 

• Powered by 6 AA alkaline batteries

• Easy loading 

P1

cassettes with automatic label recognition

includes both label materials and ribbon

• Advanced functions include serialisation, barcode printing, vertical

and horizontal lines, rotated or vertical text, variety of font
sizes/styles and a symbol library containing electrical, data
communications and facility identification symbols

*Cannot be used to charge batteries.

Part Number

Part Description

Std.

Pkg.

Qty.

LS8

Includes LS8 printer, 1 cassette of S100X150VAC self-laminating
labels, 6 AA alkaline batteries and quick reference card.

1

LS8-KIT

Includes LS8 printer, 1 cassette of S100X150VAC self-laminating
labels, 6 AA alkaline batteries, hard carrying case, LS8-PCKIT,
LS8-IB, LS8-WS and quick reference card.

1

LS8-AC E/U

100-240 V AC adapter with E-Europlug or U-UK plug.

1

LS8-PCKIT

Includes USB cable and PC interface software for importing data,
system upgrades or printing from a computer.

1

LS8-CASE

Hard carrying case.

1

LS8-CLN

Cleaning cassette.

1

LS8-IB

Protective impact bumper.

1

LS8-WS

Wrist strap.

1

Panduit-Pannet-html.html
background image

351

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

*Order number of labels required in multiples of Std. Pkg. Qty.

Part Number

Part Description

Width

Length

Print-On

Height

Min. Cable

Diameter

Max. Cable

Diameter

Std.

Pkg.

Qty.*

Std.
Ctn.
Qty.

mm

mm

mm

mm

mm

S100X125FAJ

White self-laminating polyolefin labels

25.40

31.75

12.70

3.05

5.08

5040

3024

S100X150FAJ

White self-laminating polyolefin labels

25.40

38.10

12.70

3.05

5.08

5040

3024

S100X160FAJ

White self-laminating polyolefin labels

25.40

40.64

20.32

2.79

6.86

5040

3024

S100X225FAJ

White self-laminating polyolefin labels

25.40

57.15

19.05

6.10

14.22

1008

6048

S100X400FAJ

White self-laminating polyolefin labels

25.40

101.60

25.40

7.87

17.78

1008

6048

S200X225FAJ

White self-laminating polyolefin labels

50.80

57.15

19.05

6.10

14.22

1008

6048

S200X400FAJ

White self-laminating polyolefin labels

50.80

101.60

25.40

7.87

17.78

1008

6048

Self-Laminating Label Cassettes

Order number of cassettes required.

Part 
Number

Description

Width

White print-on, vinyl label for                
18 – 14 AWG wires, 450/cassette.

S050X075VAC

• Labels offer crisp, clear legends with superior legibility

• Self-laminating labels for wire/cable labelling include a coloured print-on area and clear overlaminate to 

protect the legend for clear and durable identification

• Labels are available in a large range of wire/cable sizes

mm

12.70

Length

mm

19.05

Print-On

Height

mm

6.35

Min. Cable

O.D.

mm

2.02

Max. Cable

O.D.

mm

4.04

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

1

10

White print-on, vinyl label for                
12 – 10 AWG wires, 225/cassette.

S050X125VAC

12.70

31.75

9.65

3.07

7.03

1

10

White print-on, vinyl label for Category 5/
Category 5e/Category 6 cables,
200/cassette.

S050X150VAC

12.70

38.10

12.70

4.04

8.09

1

10

White print-on, vinyl label for                
18 – 14 AWG wires, 350/cassette.

S100X075VAC

25.40

19.05

6.35

2.02

4.04

1

10

White print-on, vinyl label for                
12 – 10 AWG wires, 225/cassette.

S100X125VAC

25.40

31.75

9.65

3.07

7.03

1

10

White print-on, vinyl label for Category 5/
Category 5e/Category 6 cables,
200/cassette.

S100X150VAC

25.40

38.10

12.70

4.04

8.09

1

10

White print-on, vinyl label for 8 – 4 AWG
wires, 125/cassette.

S100X225VAC

25.40

57.15

19.05

6.06

12.13

1

10

White print-on, vinyl label for 2 – 1 AWG
wires, 75/cassette.

S100X400VAC

25.40

101.60

25.40

8.09

24.26

1

10

White print-on, vinyl label for 1/0 – 250
MCM wires, 50/cassette.

S100X650VAC

25.40

165.10

38.10

12.13

40.43

1

10

Self-Laminating Labels for Laser/Ink Jet Desktop Printers Supplied on 
216mm x 279mm (US letter sheets)

Part Number System for Wire/Cable Labelling

S = Self-Laminating

Wire/Cable Label

Print Method

C =

P1

Cassette

VA = Vinyl

S

0

5

0

X

0

7

5

V

A

C

Width

(In.)

Label Type

“X”

Length

(In.)

Material

Panduit-Pannet-html.html
background image

352

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

L

ABEL

C

ORE

Fibre Optic Cable Identification System

• Provides a larger labelling surface on small fibre cables and allows legends to be clearly seen

• Sleeve is made of flexible PVC material

• Locate sleeve on straight section of cable at least 50.8mm from fibre boot

Apply 

L

ABEL

C

ORE

sleeve to cable

Wrap self-laminating 

label around

L

ABEL

C

ORE

sleeve

L

ABEL

C

ORE

sleeves

labelled and installed

Part 
Number

Description

Std.
Ctn.
Qty.

Std.

Pkg.

Qty.

Yellow, cable identification sleeve, 2mm simplex cable.

100

1000

NWSLC-2Y

White, cable identification sleeve, 3mm duplex fibre cable.

100

1000

NWSLC-7Y

Orange, cable identification sleeve, 3mm simplex cable.

100

1000

NWSLC-3Y

Order number of sleeves required.

Self-Laminating Label Cassettes for Use with L

ABEL

C

ORE

Fibre Optic 

Cable Identification System

Part 
Number

Description

Width

White print-on, self-laminating vinyl label
175/cassette. For use with NWSLC-2Y
and NWSLC-3Y.

S100X160VAC

mm

25.40

Length

mm

40.64

Print-On

Height

mm

20.32

Min. Cable

O.D.

mm

6.35

Max. Cable

O.D.

mm

6.35

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

1

10

White print-on, self-laminating vinyl label
125/cassette. For use with NWSLC-7Y.

S100X220VAC

25.40

55.88

27.94

12.19

12.19

1

10

Order number of cassettes required.

Non-Laminated Label Cassettes

Part 
Number

Description

Width

White, vinyl cloth label for 18 – 14 AWG wires,
125/cassette cables. 

N050X075CBC

mm

12.70

Length

mm

19.05

Min. Cable

O.D.

mm

6.10

Max. Cable

O.D.

mm

12.95

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

1

10

Order number of cassettes required.

White, vinyl cloth label for Category 5/Category
5e/Category 6 cables, 75/cassette.

N050X150CBC

12.70

38.10

12.19

25.91

1

10

White, vinyl cloth label for 8 – 4 AWG wires, 50/cas-
sette.

N100X175CBC

25.40

44.45

14.22

30.23

1

10

White, vinyl cloth label for 12 – 10 AWG wires, 75/cas-
sette.

N100X125CBC

25.40

31.75

10.16

21.59

1

10

• Labels offer crisp, clear legends with superior legibility

• Use as a wrap around label or flag style marker for wire/cable labels

• Labels are perforated so they can be used as full-size or half-size markers

• Available in vinyl cloth material for long-term or temporary labelling

Panduit-Pannet-html.html
background image

353

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

General Component Label Cassettes

Part 
Number

Description

Width

White, polyester label, 750/cassette.

C060X020YJC

mm

15.24

Height

mm

5.08

1

10

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Order number of cassettes required.

• Labels offer crisp, clear legends with superior legibility

• Multi-purpose labels for identifying flat surfaces such as components, control panels, circuit boards

and general labelling

• Available in polyester and vinyl cloth materials

White, polyester label, 500/cassette.

C100X025YJC

25.40

6.35

1

10

White, vinyl cloth label, 175/cassette.

C100X050CBC

25.40

12.70

1

10

White, polyester label, 500/cassette.

C100X050YJC

25.40

12.70

1

10

White, polyester label, 250/cassette.

C150X075YJC

38.10

19.05

1

10

White, vinyl cloth label, 50/cassette.

C200X050CBC

50.80

12.70

1

10

White, polyester label, 200/cassette.

C200X050YJC

50.80

12.70

1

10

White, polyester label, 200/cassette.

C200X100YJC

50.80

25.40

1

10

U

LTIMATE

ID

Network Label Cassette

• Label cassettes designed for use with 

U

LTIMATE

ID™ faceplates, patch panels, marker ties, modular furniture

faceplates, surface mount boxes and components

• Labels assist in compliance with TIA/EIA-606-A labelling standard

• Available in non-adhesive polyester material

Part 
Number

Description

Height

White, non-adhesive polyester label cassette.

UILS8BW

mm

6.0

Length

m

7.6

1

10

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Order number of cassettes required.
For complete 

U

LTIMATE

ID

Network Labelling System product information visit www.panduit.com.

Panduit-Pannet-html.html
background image

354

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

• Labels offer crisp, clear legends with superior legibility

• Use for identifying patch panels, faceplates, punchdown blocks and other network systems hardware

• Die-cut labels designed to provide maximum aesthetic quality and appearance

• Available in polyolefin and non-adhesive polyester materials

Network Component Label Cassettes

Part 
Number*

Description

Width

White, polyolefin label, 500/cassette, one port identifier. 

C061X030FJC

mm

15.49

Height

mm

7.62

1

10

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

Order number of cassettes required.
*To find the suggested label solutions for a specific network component, refer to the 

P

AN

-N

ET

Network Solutions catalogue 

available online at http://www.panduit.com/ncg1 and search by network component part number using the find function. 

White, polyolefin label, 200/cassette, two port identifier. 

C125X030FJC

31.75

7.62

1

10

White, polyolefin label, 200/cassette, module. 

C138X019FJC

35.05

4.83

1

10

White, polyolefin label, 150/cassette, three port identifier. 

C188X030FJC

47.75

7.62

1

10

White, non-adhesive polyester label, 100/cassette, single
gang faceplate. 

C195X040Y1C

49.53

10.16

1

10

White, polyolefin label, 150/cassette, SLCT.

C200X100FJC

50.80

25.40

1

10

White, polyolefin label, 125/cassette, four port identifier. 

C252X030FJC

64.01

7.62

1

10

White, polyolefin label, 125/cassette, four port identifier. 

C261X030FJC

66.29

7.62

1

10

White, non-adhesive polyester label, 75/cassette, four 
port identifier. 

C261X035Y1C

66.29

8.89

1

10

White, non-adhesive polyester label, 75/cassette, four 
port identifier. 

C282X030Y1C

71.63

7.62

1

10

White, non-adhesive polyester label, 150/cassette, double
gang faceplate. 

C288X040Y1C

73.15

10.16

1

10

White, polyolefin label, 100/cassette, five port identifier. 

C315X030FJC

80.01

7.62

1

10

White, polyolefin label, 75/cassette, six port identifier. 

C379X030FJC

96.27

7.62

1

10

White, non-adhesive polyester label, 30/cassette, 
110 block. 

C750X050Y1C

190.50

12.70

1

10

White, non-adhesive polyester label, 50/cassette, six 
port identifier. 

C390X030Y1C

99.06

7.62

1

10

White, non-adhesive polyester label, 30/cassette, 
GP6

system. 

C788X050Y1C

200.15

12.70

1

10

Panduit-Pannet-html.html
background image

355

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

E

ASY

-M

ARK

Labelling Software Version 3.0 simplifies

label creation for the specific needs of your applications

• Intuitive interview process allows automatic generation of

compliant labels and signs 

• Software selects and formats the optimum label for your 

specific project

WYSIWYG

(What You See Is What You Get) user

interface, alpha/numeric serialisation, data import, symbol
import

E

ASY

-M

ARK

Labelling Software Version 3.0 is part 

of a complete line of innovative identification solutions 
from 

PANDUIT

• Supports most WINDOWS^ fonts drivers for standard

thermal transfer, dot matrix, laser and ink jet, including

PANDUIT

thermal transfer printers

E

ASY

-M

ARK

Labelling Software Version 3.1 available in

French, German, Italian, Spanish and Portugese 

System Requirements:

• WINDOWS^ 98, 2000, NT4.x or XP; processor with 64MB

hard drive space and 40MB RAM

E

ASY

-M

ARK

Labelling Software Version 3.0

^WINDOWS and EXCEL are registered trademarks of Microsoft Corp. in the United States and/or other countries.

CAD-C

ONNECT

Labelling Software

• Generates labels quickly and easily directly from an electronic

CAD file

• Eliminates steps and time spent manually copying CAD

identifiers into labelling software

• Program combines the power of an innovative wizard

interview and 

E

ASY

-M

ARK

Labelling Software to capture

and organise identifiers from electronic CAD files to
automatically create and print labels 

• Compatible with AutoCAD* 2000i and Visio^ 2002 or newer

versions of CAD 

• Exports to alternative formats such as EXCEL (XLS) or

Text (CSV) files for future use and documentation

System Requirements:

• WINDOWS^ 98, Me, 2000, NT4.x and XP; minimum 486

processor; minimum 32MB RAM; 64MB hard drive space

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

PROG-CCCD

CAD-C

ONNECT

labelling software, including 

E

ASY

-M

ARK

labelling

software version 3.0, supplied on CD-ROM.

1

10

*AutoCAD is a registered trademark of Autodesk, Inc.
^Visio and WINDOWS are registered trademarks of Microsoft Corp. in the United States and/or other countries.

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

PROG-EMCD3

E

ASY

-M

ARK

labelling software version 3.0 supplied on CD-ROM.

1

10

Panduit-Pannet-html.html
background image

356

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

U

LTIMATE

ID

Network System Labelling Software

U

LTIMATE

ID

software is part of a complete system for

identification designed to efficiently support TIA/EIA-606-A
standard labelling requirements; reference pages 357 - 369
for a complete system overview

• Fast and easy creation of labels for 

U

LTIMATE

ID

Network Labelling System patch panels, faceplates, 
surface mount boxes, and marker ties

• Create alpha and numeric serialisations
• ODBC (Open Data-Base Connectivity) allows importing

of information from electronic databases such as EXCEL^
and ACCESS^ directly onto the label formats

U

LTIMATE

ID

System formats are preloaded and ready

to use

• On-line help function files, including the TIA/EIA-606-A

Labelling Compliance Brochure that assists in
understanding the TIA/EIA-606-A standard

• Easy to install and supplied on CD-ROM
• Image library that includes commonly used symbols for fax,

data and voice

• Automatically aligns legends with ports on patch panels

and faceplates

• Vertical line function enables users to separate legends
• Automatic font sizing
• Supports most WINDOWS^ printer drivers and is

compatible with standard desktop laser and ink jet printers

System Requirements:

• WINDOWS^ 95, 98, Me, 2000, NT 4.x, and XP; minimum

486 processor; minimum 10MB of RAM; 30 MB hard
drive space

^ WINDOWS, EXCEL and ACCESS are registered trademarks of Microsoft Corp. in the United States and
other countries.

Part Number

Part Description

Std.

Pkg.

Qty.

Std.
Ctn.
Qty.

UISW

U

LTIMATE

ID

labelling software supplied on CD-ROM.

1

10

Panduit-Pannet-html.html
background image

357

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

357

Patch cords in telecommunications room are
recommended not to exceed 16' (5 metres).

Work area cables are recommended not to exceed     

5 metres.

Work Area

TIA/EIA Standard Guide

TIA/EIA-568-B

Purpose ................................................. 357
Horizontal Cabling ..................................357
Backbone Cabling .................................. 358
Work Area  ..............................................358

Open Office Cabling

Multi-User Telecom Outlet....................... 359
Horizontal Distances .............................. 359
Consolidation Point Connector................ 359
Telecommunications Room .................... 360
Media: UTP Cabling ............................... 360
Media: Optical Fibre ............................... 361

Cabling Transmission Performance and
Test Requirements

Permanent Link....................................... 362
Channel.................................................. 362

Centralised Optical Fibre Cabling Guidelines

Pull-Through........................................... 363
Interconnect or Splice............................. 363

TIA/EIA-569-A

...................................

364-365

TIA/EIA-606-A

...................................

366-368

TIA/EIA-607

.......................................

369

Bibliography of References

................ 369

The information contained within this section contains portions of the TIA/EIA-568-B, TIA/EIA-569-A, TIA/EIA-606-A,
TIA/EIA-607 standards published by the Telecommunications Industry Association (TIA).*

"For further information on how to obtain TIA standards please go to http://global.ihs.com or contact Global
Engineering Documents at +1 303-397-7956"

TIA/EIA-568-B Commercial Building Telecommunications Cabling

Standard

Purpose

This standard specifies a generic telecommunications cabling system for commercial buildings that will support
a multi-product, multi-vendor environment. The purpose of this standard is to enable the planning and
installation of a structured cabling system for commercial buildings. This standard establishes performance and
technical criteria for various cabling system configurations for accessing and connecting their respective
elements. When applying specific applications to these cabling systems, the user is cautioned to consult
application standards, regulations, equipment vendors, and system and service suppliers for applicability,
limitations, and ancillary requirements.

Horizontal Cabling

Shall be star topology:

Each work area telecommunications
outlet/connector shall be connected to a
horizontal interconnect or cross-connect in a
telecommunications room via the horizontal
cable. Horizontal cabling shall contain no more
than one transition point or consolidation point
between the horizontal cross-connect and
telecommunications outlet.

Work

Area

Work

Area

Work

Area

Work

Area

Closet

The maximum total length including patch cords and work area cables is 100 metres.

Telecommunications Room

• One outlet/connector shall be a four-pair 100-ohm cable, 

Category 3 or higher (Category 5e or Category 6 recommended)

• Second outlet/connector(s) shall be a minimum of one of the following: 

1) four-pair 100-ohm Category 5e cable or Category 6
2) two-fibre multimode optical fibre cable, either 62.5/125mm or 50/125mm

A minimum of two outlets are required for each individual work area.

Panduit-Pannet-html.html
background image

358

Order number of pieces required, in multiples of Standard Package Quantity.

358

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Backbone Cabling

The function of the backbone cabling
is to provide interconnections
between telecommunications rooms,
equipment rooms, main terminal
space and entrance facilities in the
telecommunications cabling system
structure. Backbone cabling also
includes cabling between buildings.

Main

Cross-Connect

Shall be hierarchical
star topology:

Recognised backbone cables are:
a) 100-ohm twisted-pair cable (Category 3, 5e and 6)
b) multimode optical fibre cable, either 62.5/125μm or

50/125μm

c) singlemode optical fibre cable

Intermediate Cross-

Connect (Optional)

Telecommunications

Room

Telecommunications

Room

Maximum distance between main cross-connect and telecommunications room:
• 100-ohm twisted-pair (voice only) = 800 metres
• Category 3 100-ohm twisted-pair (appl. to 16 MHz) = 100 metres*
• Category 5e 100-ohm twisted-pair (appl. to 100 MHz) = 100 metres*
• Category 6 100-ohm twisted-pair (appl. to 100 MHz) = 100 metres*
• Multimode Fibre (62.5/125μm or 50/125μm = 2000 metres
• Multimode Fibre (850mm laser optimised 50/125μm = 300 metres
• Singlemode Fibre = 3000 metres

*Includes equipment patch cords at both ends.

Work Area

The Work Area is the location where the
work station equipment interfaces with the
telecommunications outlet/connector in the
cabling system. The work station equipment
can be any of a number of devices including
but not limited to telephones, data terminals
and computers.

Design for easy moves, adds
and changes.

Application specific
electrical components
shall be placed external
to the faceplate.

Telecommunications

Room

Telecommunications

Room

Panduit-Pannet-html.html
background image

359

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

359

Open Office Cabling

Provides two additional cabling options for open office environments. A multi-user telecom
outlet assembly (MUTOA) and consolidation point (CP).

Multi-User Telecom Outlet Assembly
(MUTOA)

• Horizontal cables are terminated in a

common location

• The work area cables shall be connected

directly to work station equipment without any
additional intermediate connections

• Shall serve no more than 12 work areas
• Shall be permanently mounted, not in

ceiling spaces

Horizontal Distances for 
Copper Links

Allows for the Work Area cable to extend up to 
22 metres. As compensation for this increased 
work area cable length, the horizontal cable length 
must be reduced by the formulas shown below.

C = (102 - H)/1.2

W = C - 5 <= 22 metres

Where W is the work area cable length, H is the
horizontal cable length, and C is the total combined
length of work area cable, patch cords, and equipment
cable. The table summarises these formulas.

Horizontal Distances for Fibre Optical Links

Any combination of horizontal cables, work area cables, patch
cords and equipment cables is acceptable as long as total length
does not exceed 100 metres.

Consolidation Point Connector

• Interconnection point within horizontal cabling
• Work area outlet is retained
• Serve no more than 12 work areas
• No more than one allowed in each horizontal run
• Should be located at least 15 metres from the

telecommunications room

Maximum
Length of

Horizontal Cable

H

metres

Maximum Length of

Work Area Cable

W

metres

Maximum Length of

Work Area Cable
Patch Cords and

Equipment Cable

C

metres

90

85

80

75

70

5

9

13

17

22

10

14

18

22

27

NOTE: The formulas and table above assume that the total length of the
telecommunications closet patch cords is 16' (5 metres).

Panduit-Pannet-html.html
background image

360

Order number of pieces required, in multiples of Standard Package Quantity.

360

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Media: UTP Cabling

Recognised Categories of UTP cabling are as follows:

Category 6: Requirements specified up to 250 MHz
Category 5e: Requirements specified up to 100 MHz
Category 3: Requirements specified up to 16 MHz

Horizontal Cabling:

• Cable specified is 22 or 24 AWG solid 4-pair

unshielded twisted-pair

• Overall shield (referred to as screened twisted-pair

cable -  ScTP) is also allowed

Cable shall be terminated to an 8 position modular jack.

Pin/Pair Assignment: T568A

Pin/Pair Assignment: T568B (Optional)

Pair 3

Pair 1

Pair 2

Pair 4

1

8

7

6

5

4

3

2

G

O

Pair 2

Pair 1

Pair 3

Pair 4

1

8

7

6

5

4

3

2

O

G

Telecommunications Room

The primary function of the
telecommunications room is the
termination of horizontal and
backbone cables to compatible
connecting hardware.

Cable Management Precautions:

• Avoid cable stress/tension
• Use appropriate cable routing  

and dressing fixtures

• Cables should not be routed 

in tightly circled bundles

• All connections between horizontal and backbone 

cables shall be cross-connects

• Shall be designed according to TIA/EIA-569-B

Interconnection

Cross-Connection

Common Equipment

Equipment Cord

Connecting Hardware

Patch Cord

Horizontal Cable

Work Area Outlet

Use 

T

AK

-T

Y

™ Hook & Loop

cable ties in the telecommunications

room. (See page xx)

Installer

Tip

Panduit-Pannet-html.html
background image

361

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

361

Media: UTP Cabling Practices

Minimum bend radius under no load
shall be four times the cable diameter

Maximum cable diameter for  
Category 5e cable is 6.35mm

.25" X 4 = 25.4mm

• Maintain pair twists as close as possible to the point of termination
• Untwisting shall not exceed 13mm for Category 5 cables

or higher

• Untwisting shall not exceed 25mm for Category 3 cables
• Maximum pulling tension = 110N
• Strip back jacket only as far as required for proper termination

Patch Cords

• Patch cords should be of stranded construction

• Patch cords require the same transmission  

requirements as horizontal cable with the 
exception of attenuation (20% more attenuation is 
allowed for stranded cable)

• Cross-connect jumpers and cables used for patch cords should be 

of the same performance category or higher as the horizontal  
cables to which they connect

Media: Optical Fibre
Optical fibre cabling for horizontal and
backbone applications:

• Horizontal:

Two-fibre multimode optical fibre cable, either 62.5/125μm
or 50/125μm

• Backbone:

Multimode, optical fibre cable, either 62.5/125mm or 50/125mm, 
or singlemode optical fibre cable

Inside Plant Cabling Practices:

• 2- and 4-fibre cables intended for horizontal or centralised cabling shall

support a bend radius of 25mm under no-load conditions.
Maximum pulling tension = 222N

Optical fibre patch cords:

• Must be two-fibre cable of an indoor

construction, with the same fibre type as the
optical fibre cabling

Panduit-Pannet-html.html
background image

362

Order number of pieces required, in multiples of Standard Package Quantity.

362

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Cabling Transmission Performance and Test Requirements

Specifies the electrical characteristics of field test instruments, test methods, and minimum
transmission requirements for 100-ohm twisted-pair cabling.

Applicable to:

• 100-ohm four-pair UTP and ScTP cabling only
• Horizontal cable only

Permanent Link

• Used to verify the performance of permanently

installed cabling

• Includes cable and connecting hardware only
• Limited to 90 metres

Test Parameters

The primary field test parameters are:

a) Wire map
b) Length
c ) Insertion loss
d) Near-end crosstalk (NEXT) loss*
e) Power sum near-end crosstalk (PSNEXT) loss
f ) Equal-level far-end crosstalk (ELFEXT)
g) Power sum equal-level far-end crosstalk

(PSELFEXT)

h) Return loss
i ) Propagation delay 
j ) Delay skew

Channel

• Includes cable, connecting hardware and patch

cords

• Defines entire channel
• Limited to 100 metres
• The total length of equipment cords, patch

cords or jumpers and work area cords shall not
exceed 10 m

*Near End Cross-Talk is defined as the coupling on one pair when another pair is transmitting.

Panduit-Pannet-html.html
background image

363

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

363

Centralised Optical Fibre Cabling Guidelines

• Centralised cabling design shall allow for

migration (in part or in total) of the pull-through, 
interconnect, or splice implementation to a
cross-connection implementation 

• Centralised cabling design shall allow for the 

addition and removal of horizontal and intrabuilding
backbone fibres

Pull-Through

• The layout of both rack-mount and wall-mount 

termination hardware should accommodate 
modular growth in an orderly manner

• The specifications of ANSI/TIA/EIA-569-A shall 

be followed

• Centralised cabling shall support the labelling 

requirements of ANSI/TIA/EIA-606-A

• Continuous sheath cables pulled from a centralised  

cross-connect through the telecommunications
room to the work area

• Length from the centralised cross-connect to the 

work area is limited to 90 metres

Interconnect or Splice

• Provide interconnection or splice in the 

telecommunications room

• Length from the centralised cross-connect to the  

work area is limited to 300 metres

• The intrabuilding backbone fibre count should be

sized to deliver present and future applications to 
the maximum work area density within the area 
served by the telecommunications room 

• Generally, two fibres are required for each 

application delivered to a work area

Provides guidelines for implementing a centralised optical fibre cabling system. 
It offers three alternatives to installing a cross-connect in the telecommunications room. 
These three alternatives are Pull-Through, Interconnect or Splice.

Panduit-Pannet-html.html
background image

364

Order number of pieces required, in multiples of Standard Package Quantity.

364

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

TIA/EIA 569-A Commercial Building Standard for

Telecommunications Pathways and Spaces 

Purpose

This standard specifies the design and construction practices in support of telecommunications media and
equipment. Standards are given for spaces and pathways into and through which telecommunications
equipment and media are installed within and between commercial buildings. 

General Guidelines

• Perimeter raceways are often installed at baseboard, chair-rail, or ceiling height and may contain work area

outlets. When outlets are provided, the outlet height must comply with ADA requirements where applicable. 

• Surface raceway may be used as a distribution system within and between rooms. The raceway may extend 

from building pathways to furniture pathways to connect furniture partitions or furniture systems. 

• Surface raceway consists of base, cover and related fittings that mount directly on walls at appropriate work 

levels to provide a continuous perimeter pathway. Telecommunication outlets are located along the raceway
and may be moved or added after initial installation if desired.

• Multi-channel raceway provides a separate perimeter pathway for different cable systems. Separate channels

are maintained for each cable system throughout the routing scheme by a divider-wall, either pre-configured or
modular.

Separation between Telecommunications and Power Cables

Co-installation of telecommunications cable and power cable is governed by the applicable electrical code for
safety. Recommended separation examples of electrically conductive telecommunications cable from branch
circuits are as follows:

• Separation from power conductors
• Separation and barriers within raceways
• Separation within outlet boxes or compartments

(Articles 388.70 and 800-52 of the 2002 NEC require a physical barrier between power and
telecommunication cables). 

Bend Radius Control

Surface raceway shall incorporate a bend radius of not less than 25.4mm under a condition of maximum fill.

Pathway Sizing

For planning perimeter pathways, the maximum fill shall be 40 percent. A maximum fill of 60 percent is allowed
to accommodate unplanned additions after initial installation. The practical raceway capacity for
telecommunication cabling will deviate depending on the cable-bending radius. The fill capacities of surface
raceways may approach 60% when appropriate bend radius is provided. Factors that affect fill capacity
(raceway usable area, fittings, terminations, etc.) are discussed on the following page.

Panduit-Pannet-html.html
background image

365

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

365

Raceway Internal Area

Cable Area

Pathway Sizing 

(continued)

The following guidelines can be used to provide cable fill quantities when specifying 

P

AN

W

AY

™ Surface

Raceway Systems.

Example:

Find the SPEC and MAX cable quantities for LDP3 (internal area = 135.48mm

2

) when routing

Category 5e UTP cabling (dia = 5.5mm)

Note 1: New installations of perimeter raceway systems should be sized using a cable fill based on 40%
of the raceway usable internal cross-sectional area. A maximum cable fill approaching 60% of the
raceway usable cross-sectional area may be attained if the pathway provides the appropriate bend
radius for the radius of the cable being routed. 

Note 2: Power cable fill capacities of non-metallic surface raceways are determined by the UL 5A
temperature test. The published power wire fill capacity tables indicate the maximum number of power
conductors that can be placed into the raceway channel or indicated configuration.

PANDUIT ™ Quick Wire Fill Capacities reference only the usable area for each system configuration.

NOTE:  The information provided above is intended for use only as a guideline.  Please refer to the specified document for detailed
descriptions or standards information.

Initially one may think...

RACEWAY AREA

# of Cables that

But in reality this is impossible... Why?

CABLE(S) AREA

fit in the Channel

Consider this...

=

• Cable placed into the channel leave

some unusable area depending on the 
diameter of the cable and shape of the
raceway channel. Commonly referred to
as the “packing factor.”

• If the cables being routed require a 

25.4mm bend radius and the fittings 
have a smaller radius even less internal
area is available for cables.

• Termination devices

placed within the
surface raceway also
reduce the available
internal area within

the channel.*

• Add in other real world

considerations, such as,
interwoven/crossed
cables and the usable
area becomes

even less.

The Packing Factor

= Unusable

Area

= Unusable

Area

1" Bend Radius
Fitting

Fitting w/o
1" Bend Radius

h

w

Area in Open Channel

Area w/devices installed

= Area for Cables

TIA/EIA 569-A Commercial Building Standard for

Telecommunications Pathways and Spaces (continued)

SPEC 

= X 

40%

Raceway Internal Area

Cable Area

MAX 

= X 

60%

SPEC

: The cable quantity to be used when

specifying a new raceway. This quantity leaves
room for adding cabling in the future.

MAX: 

The maximum cable quantity that will

fit into the raceway (considering factors
previously mentioned).^

^If the bend radius of the cable cannot be realised with the fittings of the system this value cannot be attained.

CABLE AREA

= TII

2

= 3.14 (5.5/2)

238.38mm

2

SPEC = 135.48mm

/ 238.38mm

2  

X 10.2mm

= 57.9

2 Cables

MAX = 135.48mm

2

/238.38mm

X 15.24mm

= 86.61

3 Cables

1. Determine Cable Area:

2. Determine SPEC Quantity:

3. Determine MAX Quantity:

Panduit-Pannet-html.html
background image

366

Order number of pieces required, in multiples of Standard Package Quantity.

366

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

TIA/EIA-606-A

Administration Standard for

Commercial Telecommunications Infrastructure

Purpose:

The TIA/EIA-606-A standard establishes guidelines for owners, end users, manufacturers, consultants,
contractors, designers, installers, and facilities administrators involved in the administration of the
telecommunications infrastructure. This standard includes requirements for identifiers, records, and 

labelling

.

Classes of Administration

Four classes of administration are specified in the standard to accommodate the varying degrees of complexity
present in telecommunications infrastructures. The specifications for each class include requirements for
identifiers, records and labelling. 

Identifiers

An identifier is a unique designation used to refer to each element of the infrastructure.

Records

A collection of detailed information related to a specific element of the telecommunications
infrastructure.

Labelling 

A label is a physical representation of an identifier that is attached to the element identified. The
size, colour, and contrast of all labels should be selected to ensure that the identifiers are easily
read. Labels should be visible during the installation of and normal maintenance of the
infrastructure. Labels should be resistant to the environmental conditions at the point of installation
(such as moisture or heat), and should have a design life equal to or greater than that of the 
labeled component. 

To maximise legibility, all labels shall be printed or generated by a

mechanical device.

Class 1

addresses the needs of a premises that is served by a single equipment room (ER). This 

equipment room is the only telecommunications space (TS) administered.

Required in class 1 administration are identifiers for the TS, each telecommunications grounding busbar (TGB),
the telecommunications main grounding busbar (TMGB), and all elements of the horizontal links 

(Patch Panel 

Ports, IDC (Punch Down Block) Connectors, Copper Four-Pair Horizontal Cable, Fibre Cable, Outlets, & 
other Connectors).

Class 2

provides for the needs of a single building with one or more telecommunication spaces.

Required in Class 2 administration are all identifiers required in Class 1 plus building backbone cable identifier,
building backbone pair or optical fibre identifier, and firestopping location identifier.

Class 3

addresses the needs of a campus, including its buildings, and outside plant elements.

Required in Class 3 administration are all identifiers required in Class 1 & 2 plus building identifiers, campus
backbone identifiers, campus backbone pair or optical fibre identifiers.

Class 4

addresses the needs of a multi-site system.

Required in Class 4 administration are all identifiers required in Class 1, 2 & 3 plus campus or site identifier.

Panduit-Pannet-html.html
background image

367

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

367

In the TS, each patch panel port 

shall be labelled

with the an portion of the identifier.

This requirement may be met by labelling a patch panel with the a portion of the
identifier, and each port with the n portion where:

a = one or two alpha characters uniquely identifying a single patch panel, or a

group of patch panels with sequentially numbered ports

n = two to four numeric characters designating the port on a patch panel in

the TS

EXAMPLE:

"B07" = patch panel B, position 07 

In the TS, each section of an IDC connector (punch-down block) terminating a four-pair
cable 

shall be labelled

with the an portion of the identifier. This requirement may be

met by labelling an IDC connector or group of IDC connectors with the a portion of the
identifier, and the section of an IDC connector terminating a four-pair cable labelled
with the n portion where:

a = one or two alpha characters uniquely identifying an IDC connector, or a

group of IDC connectors, serving as part of the horizontal cross-connect

n = two to four numeric characters designating the section of an IDC

connector on which a four-pair horizontal cable is terminated in the TS

EXAMPLE:

"B04" = IDC block B, position 04 

Each end of a horizontal cable 

shall be labelled

within 300mm of the end of the cable

jacket with the horizontal link identifier, which shall be visible on the exposed part of the
cable jacket. This shall include each cable in the TS, at the work area, and at a CP
(consolidation point), if present. A horizontal link identifier shall have a format of
fs-an where:

f = numeric character(s) identifying the floor of the building occupied by the TS

s = alpha character(s) uniquely identifying the TS on floor f, or the building

area in which the space is located

a = one or two alpha characters uniquely identifying a single patch panel, a

group of patch panels with sequentially numbered ports, an IDC
connector, or a group of IDC connectors, serving as part of the horizontal
cross-connect

n = two to four numeric characters designating the port on a patch panel in

the TS, or the section of an IDC connector on which a four-pair horizontal
cable is terminated in the TS

EXAMPLE:

"1A-AO4" = cable origination point first floor, closet A, rack A, position 04

Patch Panel Ports

IDC (Punch Down Block) Connector

Copper Four-Pair Horizontal Cable

TIA/EIA-606-A Administration Standard for

Commercial Telecommunications Infrastructure (continued)

Panduit-Pannet-html.html
background image

368

Order number of pieces required, in multiples of Standard Package Quantity.

368

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

TIA/EIA-606-A Administration Standard for

Commercial Telecommunications Infrastructure (continued)

Each end of a horizontal cable (a pair of optical fibres in a cable) shall be labelled
within 300mm of the end of the cable jacket with the horizontal link identifier, which
shall be visible on the exposed part of the cable jacket. This shall include each cable in
the TS, at the work area, and at a CP (consolidation point), if present. A
horizontal link identifier shall have a format of fs-an where:

f = numeric character(s) identifying the floor of the building occupied by the TS

s = alpha character(s) uniquely identifying the TS on floor f, or the building area

in which the space is located

a = one or two alpha characters uniquely identifying a single patch panel, or a

group of patch panels with sequentially numbered ports

n = two to four numeric characters designating the port on a patch panel in the TS

EXAMPLE:

"1D-D003" = cable origination point first floor, closet D, rack D, position 003

In the work area, each individual telecommunications outlet/connector shall be labelled
with the horizontal link identifier. The labelling shall appear on the connector, faceplate,
or MUTOA, in a way that clearly identifies the individual connector associated with the
particular identifier. A horizontal link identifier shall have a format of fs-an where:

f = numeric character(s) identifying the floor of the building occupied by the TS

s = alpha character(s) uniquely identifying the TS on floor f, or the building area

in which the space is located

a = one or two alpha characters uniquely identifying a single patch panel, a

group of patch panels with sequentially numbered ports, an IDC connector,
or a group of IDC connectors, serving as part of the horizontal cross-connect

n = two to four numeric characters designating the port on a patch panel in the TS

EXAMPLE:

"1A-B07" = origination point first floor, closet A, rack B, position 07

In the work area, each individual telecommunications outlet/connector shall be labelled
with the horizontal link identifier. The labelling shall appear on the connector, faceplate,
or MUTOA, in a way that clearly identifies the individual connector associated with the
particular identifier. A horizontal link identifier shall have a format of fs-an where:

f = numeric character(s) identifying the floor of the building occupied by the TS

s = alpha character(s) uniquely identifying the TS on floor f, or the building area

in which the space is located 

a = one or two alpha characters uniquely identifying a single patch panel, a

group of patch panels with sequentially numbered ports, an IDC connector,
or a group of IDC connectors, serving as part of the horizontal cross-connect

n = two to four numeric characters designating the port on a patch panel in the TS

EXAMPLE:

"1A-B07" = origination point first floor, closet A, rack B, position 07

Connectors

Outlets

Fibre Cable

Panduit-Pannet-html.html
background image

369

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

369

TIA/EIA-607 Commercial Building and Bonding Requirement 

for Telecommunications

Purpose

Requires a separate network grounding system that joins the power grounding system at the service entrance.

ANSI/TIA/EIA-568-B.1, 

Commercial Building Telecommunications Cabling

Standard —Part 1: General Requirements

ANSI/TIA/EIA-568-B.2, 

Commercial Building Telecommunications Cabling

Standard —Part 2: Balanced Twisted-Pair Cabling Components

—Addendum 1: Transmission Performance Specifications for

4-pair 100 W Category 6 Cabling

ANSI/TIA/EIA-568-B.3, 

Optical Fibre Cabling Components Standard

ANSI/TIA/EIA-569-A, 

Commercial Building Standard for

Telecommunications Pathways and Spaces

ANSI/TIA/EIA-606-A, 

Administration Standard for the Telecommunications

Infrastructure of Commercial Buildings

ANSI/TIA/EIA-607, 

Commercial Building Grounding and Bonding

Requirements for Telecommunications

For further information on how to obtain TIA standards please go to http://global.ihs.com

Bibliography of References

Panduit-Pannet-html.html
background image

370

Order number of pieces required, in multiples of Standard Package Quantity.

370

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

NOTES

Panduit-Pannet-html.html
background image

371

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

371

Common Terms

Access Floor

A floor which is raised by a system of pedestals and/or stringers to support removable floor panels to provide access
to the space below. The same concept as a ceiling that consists of removable panels.

Access Code 

The digits that a telephone user must dial to obtain access to a specific service connection via a particular out going
line. The 8 or 9 dialed on a hotel or company telephone is a good example.

Access Control 

The process in which a network or any of the components within it controls using entity (person, programme, etc.)
access. The most common form of access control is the use of user identification numbers and passwords.

Access Network

A "sub-network" which is implemented to provide simple access to a more complex network.  The access
network often allows communication between a limited, local, group of users and also additional access to a wider
area population.

Access Provider

A company that provides customers access to the Internet.

Address

The unique identifier for a network device (computer, printer, hub, switch, etc) within a network, used to identify the
source and receiver of a message.

American Wire Gauge (AWG)

A standardised method of specifying the size of wires. For example home wiring is carried out using AWG #14 or #12
whereas telecommunication wire is normally AWG #22, #24 or #26. The AWG number refers to the number if times the
copper is drawn through a die to reduce its diameter. Ie: 24 AWG is drawn twenty four times. Therefore the larger the
AWG number, the smaller the diameter of the wire.

Analogue Transmission

Use of voltage amplitude or frequency variations to transmit signals. Derived from the term "analogous" meaning   
similar to something. In voice, video, or imaging, the sine wave of the transmitted signal is the same as that of the
original signal.  Voice and data signals that are not digitally switched.

Application Layer 

The name of the layer within the OSI seven layer network architecture model which performs the functions necessary
to ensure the proper interaction between a computer application programme and all other network and system
software so that the desired bus end result is achieved.

Asynchronous Transmission 

The movement of binary bits across a transmission medium where the transmitter and receiver have no common time 
reference. During asynchronous transmission it is common to place controlling start and stop bits (framing) around
each individual encoded character.

Asynchronous Transmission Mode (ATM)

A technology used for Broadband Integrated Services Digital Network (BISDN). A high-speed cell switched technology
that transmits broadband signals in fixed length 53 byte cells.

Attenuation

The loss of the strength of the signal as it is transmitted from output to input measured in dBs. Lower the dB values
indicate less signal loss thus better signal transmission. 

Attenuation to Crosstalk Ratio (ACR)

A calculation that accounts for the loss of signal strength and noise coupling between the pairs on Unshielded Twisted
Pair (UTP) cable. It is determined by subtracting the attenuation dB value from the crosstalk dB value.

Autotest

A function of field test devices that allows the device to automatically run all of the required tests in a
sequential manner.

Panduit-Pannet-html.html
background image

372

Order number of pieces required, in multiples of Standard Package Quantity.

372

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Backbone Cabling

The components (cable and connecting hardware) that provide connections between entrance facilities, equipment
rooms, and telecommunications rooms.

Balanced Transmission Line 

A line having conductors with equal resistance per unit length and equal capacitance and inductance between each 
conductor and ground. 

Balun

Balanced/Unbalanced. An impedance matching device, which converts, unbalanced signal transmission to balanced.
Matches coax to twisted pair.

Bandwidth

The portion of a spectrum of frequencies, which can be effectively used to transmit information, expressed in Hz. 

Baseband  Signal

Any transmission, analog or digital, where the signal travels from the transmitter to the receiver at the original frequency.

Baseband Transmission

A transmission technique in which the total available bandwidth is dedicated to a single communications channel.
Only one single message can be transmitted at a time.

Basic Link

A link test configuration that consists of up to 90 metres of horizontal cable with a connector on each end and up to 2
metres of test equipment cord on each end.

Baud Rate 

The signaling rate of a transmission medium. A 2400 baud line carries 2400 signal changes per second.  This number
may or may not be equal to the bit rate depending on whether or not one signal change equals one bit.

Bend Radius

Indicates the minimum radius that a cable may be bent  before disrupting the signal carrying capabilities of the cable.

Binary Code 

An encoding technique in which a logical pattern of  zeros and ones is used to represent "real world" information.

Bit Error Rate (BER)

The ratio of bits received in error to the total number of bits transmitted in a digital signal transmission.

Bits per Second (BPS)

A measure of the transmission speed of a signal transmission system.  May not be the same as baud rate depending
on how the encoding of logical ones and zeros is performed.

BNC Connector 

A specific type of connector used for coaxial cable connection that requires a twist-lock type of connection.

Bonding

A continuous electrical path formed by permanently joining metallic components together to safely conduct any 
electrical current imposed and to limit any potential differences between the metal components.

Bridge

A general term used to describe electronic devices, which interconnect segments of the same logical network, or to
connect separate LANs. 

Bridge Tap 

An undefined length of wire connected between the normal end points of a circuit, which introduces an unwanted 
modification of the transmission path characteristics.

Broadband Transmission 

The transmission of multiple signals at the same time over the same physical medium, sharing the entire bandwidth of
the medium. Signals are divided, usually by frequency divisions.

Panduit-Pannet-html.html
background image

373

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

373

Buffer Coating

A thin thermoplastic coating applied to the acrylate layer of optical fibre to provide strength and protection against 
environmental hazards.

Buffer Tube

A loose fitting cover for loose tube constructed optical fibre cables to provide protection and isolation.

Bus Topology 

The physical layout of a LAN whereby connection between devices is accomplished by connecting all devices to a 
single transmission medium (wire, fibre, etc.). 

Byte 

A set of eight bits. May also be referred to as an octet. A general term, computer and data communications devices
often use 8 bit bytes which do not have any "real world" equivalent.

Cable 

A collection of metallic wires or optical fibres surrounded by an insulator through which electric current or light can
be passed.

Campus

Buildings and grounds having legal contiguous interconnection.

Capacitance

The tendency of an electronic component or conductor to store electrical energy.

Carrier Sense Multiple Access with Collision Detection (CSMA/CD)

An access method used in LAN technology, which allows devices to contend for network access.  A device, which has
data to transmit monitors the line (carrier sense) and transmits data when it determines the medium is free (no 
transmissions from other stations).  Since more than one device may attempt to transmit at the same time, this
process can result in collisions.  If a collision is detected (collision detect) during transmission, the transmitting device
(all transmitting devices) cease transmission and wait a period of time and then try again (multiple access).  This
access method with a randomised exponential back off is the medium access method specified in the IEEE 802.3
(Ethernet) LAN specification.

Central Office (CO)

The access provider's facility where customers lines are terminated and where the switching equipment to 
interconnect the lines is located.

Central Processing Unit (CPU)

A combination of the logic processor and timing control used as the basis of a digital computer.  Commonly used to
mean "computer".

Centralised Cabling

Based upon TIA/EIA TSB72 and incorporated into TIA/EIA-568-B.3. Allows optical fibre cabling to extend up to 300
metres from the work area outlet to a centralised cross-connect by using an interconnect or splice in the 
telecommunications room. Also allows cables to be pulled through the telecommunications room to a centralised
cross-connect up to 90 metres from the work area outlet.

Centralised Processing 

The method whereby data from various locations is moved to a single point for computer based processing.  The
opposite to distributed processing.

Channel

1) A data communications path such as a wire, a fibre optic conductor or a broadcast frequency.  2) TIA/EIA- 568-B.1
defines a channel as up to 90 metres of horizontal cable with connectors at the work area outlet and 
telecommunications room, plus up to 10 metres of patch cords and equipment cords at the work area outlet and in the 
equipment room for a maximum length of 100 metres.

Characteristic Impedance 

The termination impedance of a balanced transmission line which will minimise end to end reflections.

Panduit-Pannet-html.html
background image

374

Order number of pieces required, in multiples of Standard Package Quantity.

374

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Circuit

A physical electrical or optical path along which electrons or light flows.  

Circuit Switching 

The process whereby a circuit is switched into place at the inception of a telephone call, or computer data transfer
session, and then maintained in place until the communications is discontinued. 

Client

The hardware (workstation) or software which requests the computational services of a specific server.

Clock 

(Or clocking signal) A transmission signal, of precisely defined frequency or pulse rate, used to synchronize a data 
transmitter and receiver.

Coaxial Cable 

An unbalanced cable where an inner conductor and an outer grounded shield are positioned about a common axis.
This type of cable has good noise immunity. 

Collision

In an IEEE 802.3 (Ethernet) network the presence of two or more transmissions on the channel at the same time is 
considered to be a collision.

Collision Detection

A method used in LAN technology to detect the presence of two or more signals on the channel at the same time. In
Baseband systems this process is simply a matter of determining the total energy level of the signal.  One signal one
energy level, two signals, twice the energy level. In an Ethernet network once a collision is detected all transmission is
ceased and retransmitted after a random period of time.

Collocation

The process whereby equipment from multiple access providers is located at the same place usually to
facilitate maintenance.

Common Carrier 

1) A communications service supplier that is regulated in the public interest by the F.C.C. Examples include AT&T,
Sprint, and MCI.  2) A communications service supplier that is rated and regulated (in the public interest) by a Federal,
State or Local Utilities Commission.

Common Mode Noise

The transient (unwanted) voltage that appears between each signal conductor to ground. Caused by electrostatic or 
electromagnetic induction.

Communications Plenum Cable (CMP) 

Cable that has an outer jacket that is rated for low smoke/ low flame tolerance and can be installed in areas in which 
conditioned air is circulated.

Communications Riser Cable (CMR) 

Cable that has an outer jacket that has fire resistant characteristics to prevent the carrying of fire from floor to floor
and therefore can be installed in vertical runs in multi-story buildings.

Communications Server 

An intelligent device providing communications services for a population of users. Heavily used in local area networks
to provide access to wide area services.

Community Antenna Television (CATV)

A television distribution service utilising a broadband cable based transmission. Otherwise known as "Cable TV".

Compatibility

Equipment components that can be used interchangeably with each other.

Panduit-Pannet-html.html
background image

375

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

375

Compression

Any technique, which is used to reduce the number of bits, required to define information during transmission.

Concentrator

1) An analogue or digital device, which serves to reduce the number of trunks required. 2) A device, which gathers,
messages from many lines and outputs them on to one line usually at a higher speed.  Function is similar to that
of a Multiplexer.

Congestion

The condition, in a packet switched network, when node transmission buffers are full and no more incoming packets
can be accepted.

Connecting Hardware

A device providing mechanical cable terminations. 

Connectivity

The state which allows the transfer of electrical signals from source to destination.

Connector

A mechanical attachment at the end of a conductor or optical fibre which facilitates their connection to a device.

Connecting (plug), duplex; optical fibre

A remateable device that terminates two fibres and mates with a duplex receptacle. 

Consolidation Point

A location that provides the interconnection between horizontal cables extending from building pathways to horizontal
cables extending into furniture pathways.

Core

The centre portion of an optical fibre through which the light is propagated.

Coupler

A device which is utilised to connect two other devices.

Cross-Connect

A location that provides for the termination and interconnection or cross-connection for backbone and 
horizontal cables.

Cross-Connection

A connection scheme that utilises patch cords or jumper wires to connect cabling runs, subsystems, and equipment.

Cross Talk 

The undesirable coupling of signal from one conductor or pair to another. Measured in dB.

Customer Premises Equipment (CPE) 

The equipment which is installed at a customer site to interface with and connect to the common carrier's
external facilities.

Data

Any representation such as characters or bits etc to which meaning may be assigned.

Data Link 

Any serial data communications transmission path between two devices.

Data Link Layer

The layer of the OSI model that assembles messages and coordinates their flow through bridges.

Panduit-Pannet-html.html
background image

376

Order number of pieces required, in multiples of Standard Package Quantity.

376

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Data Network

Any network of interconnected devices constructed and used for, the transfer of data between the devices.

Data Rate 

A measure of transmission speed. Normally specified in bits per second.

Data Stream 

The flow of individual data bits being transmitted through a communications channel to accomplish the transfer 
of information.

Data Transfer Rate 

The average flow per unit time of information from source to destination.  The rate may be measured in terms of bits,
bytes, blocks, frames, packets, etc., per second, minute, hour, etc.

Data/Voice Multiplexor (DVM) 

A device used to combine voice and data signals on the same transmission line.

Decibel (dB) 

A unit of measure of relative power. The unit used to describe levels of attenuation.

Demarcation Point 

The point that defines the boundary for the end of the customer premises and the beginning of the public network.

Digital Signal

A signal that is transmitted in binary code. The data is encoded into a series of bits (0,1) transmitted across the cable
and deciphered at the receiver.

Distributed Processing 

The positioning of interconnected computers such that the application based "work to be done" is performed at the
best physical and/or functional points throughout a network.

Drop

An available service point. Often used to describe the wiring (in a network) which is unique to a particular user.

Drop Cable 

In local area network technology the cable used to connect a device to interface to the backbone network.

Effective Bandwidth 

The maximum bit transmission rate through a specific medium.

EIA/TIA 568-B

A standard for commercial building wiring. Its purpose is to provide a generic telecommunications wiring system to
support multi-product, multi-vendor installations. Topics covered include: media, topology, cable length & performance,
installation practices, and lab and field testing.

Electromagnetic Interference (EMI) 

Electromagnetic energy, which leaks from/into, any transmission medium that causes unwanted signals on the cable,
device, or equipment. 

Encryption

The mathematical process whereby the data in a message is modified to protect it from access to anyone other than
the intended receiver.

Enterprise Networking 

Information access in a multi vendor environment between a corporation's internal resources and suppliers, customers
and other strategic partners.

Panduit-Pannet-html.html
background image

377

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

377

Entrance Facility

The point which public and private network service cables enter a building and are terminated in an entrance room 
or space.

Equal Level Far End Crosstalk (ELFEXT) 

A measure of unwanted signal coupling between pairs of a UTP cable measured at the end opposite the signal 
transmitter, relative to the received signal, accounts for the attenuation of the signal across the cable.

Equipment Room (Telecommunications)

An environmentally controlled centralsed space for telecommunications equipment that usually houses a main or 
intermediate cross-connect.

Error Control 

The facilities within a transmission system or network which ensure the reliable transfer of data.

Error Correction 

The mechanism used to correct detected errors in a transmission. Correction is normally achieved by retransmissions
of data. 

Error Detection 

The process whereby transmission errors are detected by using simple parity checks or more complex cyclic 
redundancy checks.

Ethernet

The LAN method developed by Xerox, DEC, and Intel. Uses the CSMA/CD physical access method.  Originally
in 1979, special 50 ohm co-axial cable and 10 million bit per second digital transmission was specified.  Over
the years it has evolved to Gigabit transmissions over UTP and optical fibre.  Specified under the auspices of
IEEE 802.3 committee. 

Extended LAN 

A local area network, which has had its dimensions, extended by the use of bridges.

Facsimile (FAX) 

A process of transmitting text, graphics, etc via communications lines to a remote point where a hard copy is 
reproduced. Transmission may be Analogue or Digital.

Far-end Cross Talk (FEXT) 

A measure of unwanted signal coupling between pairs of a UTP cable measured at the end opposite the signal 
transmitter.

Federal Communications Commission (FCC)

A board of five individuals appointed by the President of the United States and charged with the task of regulating (for
the public good) communications within the U.S.

Fibre Data Distribution Interface (FDDI) 

An interface to a Fibre Optic Distribution Bus which utilises the IEEE 802.8 specifications. 

Fibre Loss 

The energy loss in a light signal caused by transmission through a fibre optic medium.

Fibre Optics 

A transmission medium which is constructed using fine glass fibres and through which information (data) is transferred
using light waves created by a laser or light emitting diode.

File Server 

A device in a LAN (or any other network) which services the filing needs of other computers, where network 
information is stored and retrieved.

Fire Stop

A device or material that is installed in architectural barriers to prevent passage of flame, smoke, water, or gases
through the rated barrier.

Panduit-Pannet-html.html
background image

378

Order number of pieces required, in multiples of Standard Package Quantity.

378

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Floor Distributor

International expression for horizontal cross-connect.

Frame

A data unit that contains data and control information to transfer data between devices on a network and is defined by
the data link layer (point to point) protocol.

Frame Relay 

A service transfers data link layer transmission frames from defined source to defined destination. 

Frequency

The rate, in Hertz, at which a signal pattern is repeated.

Frequency Band 

A specified range of available frequencies.

Full Duplex Transmission (FDX) 

Bi-directional transmission.  Transmission in both directions at the same time.

Fusion Splice

A method of splicing optical fibres together by applying heat, usually from a laser, to melt and fuse the ends of the
fibres together to form a permanent bond.

Gateway 

The hardware or software products, which create, access from one TOTAL environment to another.  (The term is often
used to describe a device that interconnects networks at ANY level.) 

Gigabit Ethernet 

A carrier sense multiple access with collision detection LAN standard developed by the IEEE 802 committee that 
operates at a data rate up to 1 gigabit per second.

Gender (Connector) 

Connectors are assigned gender to describe their physical type.  Connectors which have pins are considered to be
male and those that have sockets are considered to be female.

Graded Index Fibre

An optical fibre design in which the refractive index of the core is lower on the outer layer of the core and gradually 
increases as it moves through the layers to the centre of the core.  This allows the light to travel faster on the outer layers
of the core than in the centre.  This reduces modal dispersion and increases the fibre bandwidth.

Ground

A circuit connection to the earth.

Half Duplex (HDX) 

The process whereby a device can receive or transmit but never do both at the same time.

Hard Wired 

Describes a connection between two or more devices, which is direct and permanent.

Header

The controlling information in a transmission frame, which precedes the data, field. May be abbreviated to HDR.

Hertz 

A measure of frequency. The same as cycles per second.

Horizontal Cabling

The cabling and components that extend from the horizontal cross-connect in the Telecommunications Room to the 
termination point at the Work Area outlet.

Panduit-Pannet-html.html
background image

379

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

379

Horizontal Cross-connect

A termination point, such as a patch panel or punch down block, located in the Telecommunications Room that allows
for equipment and backbone cabling to be connected to horizontal cabling with patch cords or jumper wires.
Sometimes referred to as Floor Distributor.

Hub

A device from which a number of transmission links radiate.  The network so formed has the same configuration as a
star topology.

Hybrid Network 

1) A network that combines analogue and digital signalling. 2) A network that combines local and global connection. 
3) A network which consists of more than one architecture. 4.) Any combination of the previous definitions.

Identifier

An item of information that links a specific element of the telecommunications infrastructure with its 
corresponding record.

IEEE (IEEE) 

Institute of Electrical and Electronic Engineers. A United States professional membership organisation active in the
creation and promotion and support of specifications and standards. IEEE Computer Society. 5855 Naples Plaza,
Suite 301, Long Beach, CA 90803.

IEEE 802.3 

The specification for the physical layer in a LAN, which uses CSMA/CD as it's access method, a bus configuration and
baseband transmission. Based on original DIX Ethernet specifications.

IEEE 802.5 

The specification for the physical layer in a LAN which uses token passing as it's access method, a ring configuration
and (normally) baseband transmission. Used in IBM's implementation of ring technology.

IEEE 802.6 

The specification for a Metropolitan area network.

IEEE 802.8 

The specification for a fibre distribution bus using token passing as its access method. 

Impedance 

The combined effect of the electrical resistance, capacitance and inductance of a transmission medium. Expressed
in ohms.

Infrastructure (Telecommunications)

The Telecommunications components, excluding the equipment, that together provides the fundamental support for
the distribution of all information within a building or campus.

Insertion Loss

Loss resulting from the insertion of a device such as a coupler, connector, or splice in a transmission line.

Integrated Service Digital Network (ISDN)  

A type of network which transfers all information from source to destination in a digital form.  The network is generally
formed using a combination of circuit and packet switched facilities. 

Inter Exchange Carrier 

1. (IEC) Any common carrier who is licensed by either the FCC of a state utility commission to carry transmissions
between "local" telephone areas. Examples, currently, are AT&T Long Lines, MCI, US Sprint etc. 2. (IXC) Same as 1.

Panduit-Pannet-html.html
background image

380

Order number of pieces required, in multiples of Standard Package Quantity.

380

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Interbuilding Backbone

A backbone cabling system providing communications between more than one building.

Interconnection

A connection scheme that provides for connecting of a cable to another cable or to an equipment cable without 
utilising patch cords or jumper wires.

Intermediate Cross-connect

The connection point between  a backbone cable extending from the Main Cross-connect and the backbone cable
extending from the horizontal cross-connect. Sometimes referred to as the Building Distributor.

Intrabuilding Backbone

A backbone cabling system providing communications within a building.

Interference

Noise or other distortion during the transmission of data which may cause errors.

Internetwork

A single logical network formed by connecting two or more dissimilar networks.

Interoperability

The process whereby computational devices can operate interactively with each other across a network without data 
conversion or human intervention.

Jitter

Temporary effects caused by instability in transmission systems.

Jumper 

A cable or wire used to establish a temporary circuit connection.

Laser

Light Amplification by Stimulated Emission of Radiation. A device which emits light at a single frequency with all 
radiation "in phase". The emitted light may also be referred to as "coherent" light.

Light Emitting Diode (LED) 

A solid state device which radiates light at a single frequency. Abbreviated to LED.

Link

A transmission path that includes the cable and connecting hardware. Does not include equipment, work area cables, 
equipment cables, or patch cables. 

Local Area Network (LAN) 

An interconnecting network where distances are relatively short, speeds are high and reliability is excellent.

Local Exchange Carrier (LEC) 

The local regulated provider of public switched telecommunication services.

Longitudinal Conversion Loss (LCL) 

A measure of circuit balance. A measure of the differential voltage induced on a conductor pair as a result of 
subjecting that pair to longitudinal voltage.

Loose Tube Fibre

An optical fibre cable construction in which the buffer coating of the fibre is loosely placed around the fibre and filled
with water blocking gel.  Designed for outside plant use.

Loss

Reduction of transmission signal strength.

Panduit-Pannet-html.html
background image

381

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

381

Main Cross-connect

A connection point between entrance cables, equipment cables, interbuilding backbone cables, and intrabuilding
backbone cables.  Sometimes referred to as Campus Distributor.

Manchester Encodation 

A transmission encodation scheme where binary ones are represented by positive transitions within a time period and
binary zeros are represented by negative transitions.  This scheme is useful in high speed transmission over short distance
and is utilised in DIX Ethernet, IEEE 802.3, and many other baseband LAN implementations.

Medium

Any physical substance which is used for the transmission of signals.

Megabit

One million bits.

Megabyte 

One "computer million" (1.048576 million) eight bit bytes.

Megahertz

One million hertz or one million cycles per second.

Mode

A path of light.

Modem

A device which is used to process a digital signal so that it can be transmitted on an analogue transmission line. 
The word is derived from a contraction of the words modulator and demodulator. Modems may use amplitude,
frequency, or phase shift, modulation.

Modular Jack

A female telecommunications interface connector as specified in IEC 603-7 and FCC Part 68 Subpart F.

Modular Plug

A male telecommunications interface connector as specified in IEC 603-7 and FCC Part 68 Subpart F.

Multimedia

Applications that communicate information by more than one means or cabling media.

Multimode Optical Fibre

An optical fibre that allows many bound modes to propagate in the core.

Multiplexing

The combining of two or more communications channels into a common, high-capacity channel from which the 
original signals may be individually recovered.

Multi-user Telecommunications Outlet Assembly

A grouping in one location of several telecommunications outlet/connectors.

Multi-user Telecommunications Outlet Assembly (MUTOA) 

A group of telecommunications outlets located in one housing assembly to provide a common Work Area outlet for up
to twelve work areas in open office applications.  Work Area equipment cords are routed from the MUTOA directly to
the Work Area equipment.

Near End Crosstalk (NEXT) 

Unwanted coupling of signals between pairs of twisted pair cables measured at the source (near) end of a 
transmission link. 

Panduit-Pannet-html.html
background image

382

Order number of pieces required, in multiples of Standard Package Quantity.

382

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Network

An interconnected group of devices utilising a method or architecture, which eliminates the need for having every
device directly, connected to every other device.

Network Interface Card (NIC) 

A circuit card that is installed in equipment  to provide the means to connect the equipment to the network 
communications channel.

Noise

Portions of a signal in a transmission medium, which are the result of external influences and are NOT part of the 
original transmission.

Nominal Velocity of Propagation (NVP) 

The coefficient used to determine the speed of transmission through a medium relative to the speed of light.

Open Office

An office area with division provided by furniture, movable partitions, or other temporary needs rather than building 
permanent structural walls.

Optical Fibre 

Any glass or plastic fibre that is manufacture for the transmission of light signals.

OSI Model

Seven-layer model developed by the International Organization for Standardization (ISO) to create an open systems 
networking environment.

Outlet (Telecommunications)

A fixed connecting device where the horizontal cable is terminated and provides an interface to the work area cabling.

Packet

A predefined unit of data, which is moved from source to destination through a specific packet, switched network.

Patch Cord

A length of cable with connectors on both ends, used to join telecommunications links at a cross-connect.

Patch Panel

Connecting hardware that provides a means to connect horizontal or backbone cables to an arrangement of fixed 
connectors that may be accessed using patch cords or equipment cords to form cross connections or 
interconnections.

Pathway

The physical vertical and horizontal route of the communications cable in a structured cabling system.

Peripheral Device

Equipment that is connected external to and controlled by a computer. Examples are printers, CD Rom drives, 
scanners, and modems.

Permanent Link

Cabling and connecting hardware that extends from the horizontal cross connect to the work area outlet.  May not
exceed 90 metres.

Physical Layer 

The layer in a layered network architecture, such as the ISO OSI seven level structure for example, which is 
responsible for the actual transmission of bits across a medium.  Typical specifications include RS 232-C and the
physical layer signalling specified in IEEE 802.3. May also be referred to as the physical level.

Panduit-Pannet-html.html
background image

383

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

383

Plenum

A compartment or chamber to which one or more air ducts are connected and that forms part of the air
distribution system.

Power Sum

Used to specify a combination crosstalk from multiple sources. In a four-pair cable, it is a combination of crosstalk
from the other three pairs.

Premises Wiring

A generic term that includes interbuilding, intrabuilding, and horizontal cabling that is owned by a single tenant
or landlord.

Private Branch Exchange (PBX) 

A device that allows private local voice and other voice related services to be switched over a network.

Propagation Delay

The amount of time that passes between when a signal is transmitted and when it is received at the opposite end of
the cabling.

Protocol

A set of rules and procedures governing the formatting of messages and the timing of their exchange between devices
on a network covering addressing, transmitting, receiving, and verifying.

Pull Strength

The rated strength of a cable and of the force that can be exerted on it during installation.

Raceway

Any enclosed channel designed for housing wires, cables, or busbar.

Receiver (Optical)

An optoelectronic circuit that converts an optical signal to an electrical serial logic signal.

Record

A collection of detailed information related to a specific element of the telecommunications infrastructure.

Redundant Circuits 

Transmission paths that are available if the "primary" circuit fails or is otherwise unavailable.

Regional Bell Operating Company (RBOC) 

Each of the seven regional based holding companies which where created by the break-up of the AT&T monopoly and
are responsible for all local telephone services and operate in a variety of other communications related markets.

Report

A presentation of a collection of information from the various records.

Return Loss

A measure of the signal reflections occurring along a channel or link and is related to various electrical mismatches
along the cabling, expressed in dB.

Ring Topology 

The network structure whereby connection between devices is accomplished by arranging them in a physical ring.
This is the structure used by IBM in its token passing ring implementation of local area network technology.

Router

A devices which performs routing functions. Such a device may alter physical, data link and network level protocols to
effect interconnection between dissimilar network types.

Service Provider (SP) 

A company that provides connection to a part of the Internet, or other services such as application 
programming interfaces.

Panduit-Pannet-html.html
background image

384

Order number of pieces required, in multiples of Standard Package Quantity.

384

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

Screened Twisted Pair Cabling (ScTP)

A balanced twisted pair cable surrounded by a metallic braid, foil, or both and bound in a single cable sheath.

Shielded Twisted Pair (STP) 

A cable surrounded by a metallic braid, foil, or both and bound in a single plastic sheath containing balanced twisted
pair conductors that are individually shielded.

Signal to Noise Ratio

The ratio between the detected signal power and noise in a receiver, expressed in dB.

Simplex Transmission 

Unidirectional transmission. One direction only.

Single Mode Fibre 

A fibre optic transmission medium designed to carry light waves at a single frequency.

Skew

The time delay between any two transmitted signals.

Software

A set of computer instructions stored in computer memory and used to direct the CPU to execute a specific task(s).

Space (Telecommunications)

An area used for housing the installation and termination of telecommunications equipment and cable, e.g., common 
equipment rooms, equipment rooms, common telecommunications rooms, telecommunications rooms, work areas,
and maintenance holes/handholes.

Standard

A collection of requirements that encompasses properties of components and systems that are intended to ensure an
accepted degree of functionality and longevity.

Star Topology 

The network structure where all devices are connected through a single switching point. 

Step Index Optical Fibre 

A fibre, which has a constant refractive index at its core but a different refractive index as the outer cladding, is
approached. This design minimises losses at the core/cladding interface and is preferred for single mode long 
distance transmission.

Switching

The process whereby a connection is transferred from one circuit to another by interconnecting the two circuits.

Synchronous Optical Network  (Sonet) 

A Bellcore optical transmission network operating at T3 speeds.

T1 Carrier 

A specialized digital (AT&T) transmission system operating at a total speed of 1.544 Million bits per second using 
specific time division multiplexing techniques. A T1 carrier can support 24 voice circuits.

T3 Carrier 

A specialized digital (AT&T) transmission system operating at a total speed of 44.736 million bits per second using
specific time division multiplexing techniques. A T3 carrier can support 672 voice circuits.

Telecommunications

A general term for voice and/or data communication, which is implemented using coded signals over a medium.

Panduit-Pannet-html.html
background image

385

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

385

Telecommunications Industry Association (TIA) 

An organisation that sets standards for cabling, pathways, spaces, grounding, bonding, administration, field testing
and other aspects of the telecommunications industry.

Telecommunications Room

An enclosed space for housing telecommunications equipment, cable terminations, and cross-connect cabling used to
serve work areas on the same floor. Typical location for the horizontal cross-connect.

Throughput

The amount of data transferred between two points in a given amount of time.

Tight Buffer

A cable construction which provides each optical fibre with a tight buffer of protective thermoplastic coating to a 
diameter of 900 microns.

Time Domain Reflectometer (TDR) 

A device that sends a signal down a cable, and then measures the magnitude and amount of time required for the
reflection of that signal to return. Often used to measure the length of cables and to locate faults.

Token Ring 

A LAN configuration wherein a physical ring structure is used and device access is controlled by a rotating token.

Topology

The physical arrangement of devices in a network regardless of their logical relationships. Examples are; star, 
ring, bus.

Transceiver

1) In the IEEE 802.3 sense the attachment device which connects the controller interface to the transmission cable.
Under IEEE 802.3 this device contains the carrier sense logic, the transmit/receive logic and the collision detect logic.
2)  Any device which performs and transmission and reception function.

Transients 

Short duration transmission signals interruptions.

Transition Point

A location in the horizontal cabling subsystem where flat undercarpet cabling connects to round cabling.

Transmission 

The transfer of information from one point to another using one of many physical methods and one of many media.

Transmission Medium 

Any material which is used to carry a representation (electrical, optical etc.) of information.

Unshielded Twisted Pair 

A twisted pair transmission medium, which has no outer shielding.  While this reduces the noise elimination of the 
conductors it improves the maximum transmission speeds attainable.

Virtual Circuit 

A connection, which "appears" and "performs" as if a physical connection exists between source and destination even
if one does not.

Virtual Network

A network that is programmed, not hardwired, to meet a customers specifications.  Created on as needed basis.  May
be referred to as Virtual Private Network (VPN).

Wavelength

Length of a sine wave measured from one point on a wave to the corresponding point on the next wave, such as from
peak to peak. Wavelength of light is usually measured in nanometers.

Wavelength Division Multiplexing (WDM)

Modulates a series of data streams using a different wavelength of light for each stream and simultaneously transports the
multiple wavelengths over a single fibre.  Increases the information carrying capacity of fibre optic transmission systems.
Also referred to as Dense Wavelength Division Multiplexing (DWDM).

Work Area (WA) 

A building space where the occupants interact with telecommunications terminal equipment.

Panduit-Pannet-html.html
background image

386

Order number of pieces required, in multiples of Standard Package Quantity.

386

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

AC

Alternating Current

A-D or A/D

Analogue to Digital conversion

ACR

Attenuation to Crosstalk Ratio

ANSI

American National Standards Institute

ATM

Asynchronous Transfer Mode

AWG

American Wire Gauge

BAS

Building Automation Systems

DSL

Digital Subscriber Line

DTE

Data Terminal Equipment

EIA

Electronics Industry Association

ELFEXT

Equal Level Far End Crosstalk

EMC

Electromagnetic Compatibility

EMI

Electromagnetic Interference

EMT

Electrical Metallic Tubing

ESD

Electrostatic Discharge

FCC

Federal Communications System

FDDI

Fibre Distribution Data Interface

FDM

Frequency Division Multiplexing

FEXT

Far End Crosstalk

FOCIS

Fibre Optic Connector Interface Standard

FOTP

Fibre Optic Test Procedure

GHz

Gigahertz

Gnd

Ground

HVAC

Heating, Ventilation, Air Conditioning

Hz

Hertz

IBCS

Intelligent Building Cabling System

IC

Intermediate Cross Connect

IDC

Insulation Displacement Connector

Acronyms

Panduit-Pannet-html.html
background image

387

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

387

IEEE

Institute of Electrical and Electronic Engineers

ISDN

Integrated Services Digital Network

ISO

International Organisation for Standardisation

ITU

International Telecommunications Union

LEC

Local Exchange Carrier

LED

Light Emitting Diode

MAC

1) Media Access Control
2) Moves, Adds, and Changes

MC

Main Cross-connect

MHz

Megahertz

MM

Multimode 

MUTO

Multi-user Telecommunications  Outlet

MUX

Multiplexer

NEXT

Near End Crosstalk

NIC

Network Interface Card

NVP

Nominal Velocity of Propagation

OEM

Original Equipment Manufacturer

OSP

Outside Plant cable

OTDR

Optical Time Delay Reflectometer

PBX

Private Branch Exchange

PCM

Pulse Code Modulation

POP

Point of Presence

PVC

Polyvinyl Chloride

RFI

Radio Frequency Interference

RFQ

Request for Quote

ScTP

Screened Twisted Pair cable

SM

Singlemode

SNR

Signal to Noise Ratio

Panduit-Pannet-html.html
background image

Order number of pieces required, in multiples of Standard Package Quantity.

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

SONET

Synchronous Optical Network

SP

Service Provider

STP

Shielded Twisted Pair

TBB

Telecommunications Bonding Backbone

TDM

Time Division Multiplexing

TGB

Telecommunications Grounding Busbar

TIA

Telecommunications Industry Association

TMGB

Telecommunications Main Grounding Busbar

TR

Telecommunications Room

UL

Underwriters Laboratory

UPS

Uninterruptible Power Supply

USOC

Universal Service Order Code

VCSEL

Vertical Cavity Surface Emitting Laser

WDM

Wave Division Multiplexing

WP

Waterproof Outlet

388

Panduit-Pannet-html.html
background image

389

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

A

ABM100-A-C  . . . . . . . . . . . . . . . . . . .336
ABM100-A-C15  . . . . . . . . . . . . . . . . .336
ABM100-AT-C0  . . . . . . . . . . . . . . . . .336
ABM1M-A-C  . . . . . . . . . . . . . . . . . . .336
ABM2S-A-C . . . . . . . . . . . . . . . . . . . .336
ABM2S-A-C14 . . . . . . . . . . . . . . . . . .336
ABM2S-A-C15 . . . . . . . . . . . . . . . . . .336
ABM3H-A-L  . . . . . . . . . . . . . . . . . . . .336
ABM4H-A-L  . . . . . . . . . . . . . . . . . . . .336
ABMM-A-C  . . . . . . . . . . . . . . . . . . . .336
ABMT-A-C  . . . . . . . . . . . . . . . . . . . . .336
ABMT-A-C20  . . . . . . . . . . . . . . . . . . .336
ABMT-S6-C  . . . . . . . . . . . . . . . . . . . .336
ABMT-S6-C20  . . . . . . . . . . . . . . . . . .336
ABMT-S6-C60  . . . . . . . . . . . . . . . . . .336
ABMT-S6-C69  . . . . . . . . . . . . . . . . . .336
ACC19-A-C  . . . . . . . . . . . . . . . . . . . .340
ACC38-A-C  . . . . . . . . . . . . . . . . . . . .340
ARC.68-A-Q14  . . . . . . . . . . . . . . . . .340
ARC.68-S6-Q14  . . . . . . . . . . . . . . . .340
AVPDB  . . . . . . . . . . . . . . . . . . . . . .30,57

B

B2M2S-D . . . . . . . . . . . . . . . . . . . . . .329
B2M2S-D . . . . . . . . . . . . . . . . . . . . . .333
B3M2S-TL  . . . . . . . . . . . . . . . . . . . . .329
B3M2S-TL  . . . . . . . . . . . . . . . . . . . . .333
B4M2S-TL  . . . . . . . . . . . . . . . . . . . . .329
B4M2S-TL  . . . . . . . . . . . . . . . . . . . . .333
BC1.5I-S8-M  . . . . . . . . . . . . . . .328,333
BC1M-S4-M  . . . . . . . . . . . . . . . .328,333
BC2M-S4-M  . . . . . . . . . . . . . . . .328,333
BC2S-S10-C  . . . . . . . . . . . . . . . . . . .333
BC2S-S10-D  . . . . . . . . . . . . . . .328,333
BC4LH-S25-L . . . . . . . . . . . . . . .328,333
BC4S-S10-C  . . . . . . . . . . . . . . . . . . .333
BC4S-S10-D  . . . . . . . . . . . . . . .328,333
BEC38-A-L  . . . . . . . . . . . . . . . . . . . .340
BEC62-A-L  . . . . . . . . . . . . . . . . . . . .340
BEC75-A-L  . . . . . . . . . . . . . . . . . . . .340
BF1M-C  . . . . . . . . . . . . . . . . . . .329,333
BF1M-M  . . . . . . . . . . . . . . . . . . . . . .333
BF2M-C  . . . . . . . . . . . . . . . . . . .329,333
BF2M-M  . . . . . . . . . . . . . . . . . . . . . .333
BM1M-C  . . . . . . . . . . . . . . . . . . .329,333
BM1M-M  . . . . . . . . . . . . . . . . . . . . . .333
BM2M-C  . . . . . . . . . . . . . . . . . . .329,333
BM2M-M  . . . . . . . . . . . . . . . . . . . . . .333
BM2S-C  . . . . . . . . . . . . . . . . . . .329,333
BM2S-D . . . . . . . . . . . . . . . . . . . . . . .333
BM4S-C  . . . . . . . . . . . . . . . . . . .329,333
BM4S-D . . . . . . . . . . . . . . . . . . . . . . .333
BR2-1.3  . . . . . . . . . . . . . . . . . . . . . . .151
BR2-1.3-A  . . . . . . . . . . . . . . . . . . . . .151
BT1.5I-C . . . . . . . . . . . . . . . . . . .328,333
BT1.5I-M  . . . . . . . . . . . . . . . . . . . . . .333
BT1.5M-C . . . . . . . . . . . . . . . . . .328,333
BT1.5M-C . . . . . . . . . . . . . . . . . .328,333
BT1.5M-M  . . . . . . . . . . . . . . . . . . . . .333
BT1M-C  . . . . . . . . . . . . . . . . . . .328,333
BT1M-M  . . . . . . . . . . . . . . . . . . . . . .333
BT2.I-M  . . . . . . . . . . . . . . . . . . . . . . .333
BT2I-C  . . . . . . . . . . . . . . . . . . . .328,333
BT2LH-L . . . . . . . . . . . . . . . . . . .328,333
BT2LH-TL  . . . . . . . . . . . . . . . . . . . . .333
BT2M-C  . . . . . . . . . . . . . . . . . . .328,333
BT2M-M  . . . . . . . . . . . . . . . . . . . . . .333

BT2S-C  . . . . . . . . . . . . . . . . . . .328,333
BT2S-M  . . . . . . . . . . . . . . . . . . . . . . .333
BT3I-C  . . . . . . . . . . . . . . . . . . . .328,333
BT3I-M  . . . . . . . . . . . . . . . . . . . . . . .333
BT3LH-L . . . . . . . . . . . . . . . . . . .328,333
BT3LH-TL  . . . . . . . . . . . . . . . . . . . . .333
BT3S-C  . . . . . . . . . . . . . . . . . . .328,333
BT3S-M  . . . . . . . . . . . . . . . . . . . . . . .333
BT4I-C  . . . . . . . . . . . . . . . . . . . .328,333
BT4I-M  . . . . . . . . . . . . . . . . . . . . . . .333
BT4LH-L . . . . . . . . . . . . . . . . . . .328,333
BT4M-C  . . . . . . . . . . . . . . . . . . .328,333
BT4M-M  . . . . . . . . . . . . . . . . . . . . . .333
BT4RLH-TL  . . . . . . . . . . . . . . . . . . . .333
BT4S-C  . . . . . . . . . . . . . . . . . . .328,333
BT4S-M  . . . . . . . . . . . . . . . . . . . . . . .333
BT5LH-C  . . . . . . . . . . . . . . . . . . . . . .333
BT6LH-C  . . . . . . . . . . . . . . . . . . . . . .333
BT6LH-L . . . . . . . . . . . . . . . . . . .328,333
BT7LH-C  . . . . . . . . . . . . . . . . . . . . . .333
BT7LH-L . . . . . . . . . . . . . . . . . . .328,333
BT8LH-C  . . . . . . . . . . . . . . . . . . . . . .333
BT8LH-L . . . . . . . . . . . . . . . . . . .328,333
BT9LH-C  . . . . . . . . . . . . . . . . . . . . . .333
BT9LH-L . . . . . . . . . . . . . . . . . . .328,333
BW1.5I-D . . . . . . . . . . . . . . . . . . . . . .333
BW2S-D  . . . . . . . . . . . . . . . . . . . . . .333

C

CA3IW-X  . . . . . . . . . . . . . . . . . . . . . .320
CA5IW-X  . . . . . . . . . . . . . . . . . . . . . .320
C0125X030FJC . . . . . . . . . . . . . . . . .354
C060X020YJC  . . . . . . . . . . . . . . . . .353
C061X030FJC . . . . . . . . . . . . . . . . . .354
C100X025YJC  . . . . . . . . . . . . . . . . .353
C100X050CBC  . . . . . . . . . . . . . . . . .353
C100X050YJC  . . . . . . . . . . . . . . . . .353
C138X019FJC . . . . . . . . . . . . . . . . . . .20
C138X019FJC . . . . . . . . . . . . . . . . . . .25
C138X019FJC . . . . . . . . . . . . . . . . . .354
C138X019FJJ  . . . . . . . . . . . . . . . .20,22
C138X019FJJ  . . . . . . . . . . . . . . . . . . .25
C150X075YJC  . . . . . . . . . . . . . . . . .353
C188X019FJC . . . . . . . . . . . . . . . . . .354
C195X040Y1C  . . . . . . . . . . . . . . . . .354
C200X050CBC  . . . . . . . . . . . . . . . . .353
C200X050YJC  . . . . . . . . . . . . . . . . .353
C200X100FJC . . . . . . . . . . . . . . . . . .354
C200X100YJC  . . . . . . . . . . . . . . . . .353
C252X030FJC . . . . . . . . . . . . . . . . . .354
C261X030FJC . . . . . . . . . . . . . . . . . .354
C261X035Y1C  . . . . . . . . . . . . . . . . .354
C282X030Y1C  . . . . . . . . . . . . . . . . .354
C288X040Y1C  . . . . . . . . . . . . . . . . .354
C2FP  . . . . . . . . . . . . . . . . . . . . . . . . . .35
C2FPAW  . . . . . . . . . . . . . . . . . . . . . . .35
C2YL6  . . . . . . . . . . . . . . . . . . . . . . . .236
C315X030FJC . . . . . . . . . . . . . . . . . .354
C379X030FJC . . . . . . . . . . . . . . . . . .354
C390X030Y1C  . . . . . . . . . . . . . . . . .354
C4PPLK  . . . . . . . . . . . . . . . . . . . . . . .57
C4YL6  . . . . . . . . . . . . . . . . . . . . . . . .236
C6PPLK1-24  . . . . . . . . . . . . . . . . . . . .58
C6PPLK25-48  . . . . . . . . . . . . . . . . . . .58
C750X050Y1C  . . . . . . . . . . . . . . . . .354
C788X050Y1C  . . . . . . . . . . . . . . . . .354
CBAG  . . . . . . . . . . . . . . . . . . . . . . . . .34
CBAGAW  . . . . . . . . . . . . . . . . . . . . . .34

CBAGIW  . . . . . . . . . . . . . . . . . . . . . . .34
CBCHAW  . . . . . . . . . . . . . . . . . . . . . .37
CBF  . . . . . . . . . . . . . . . . . . . . . . . . . . .35
CBFAW  . . . . . . . . . . . . . . . . . . . . . . . .35
CBR1.5I-M  . . . . . . . . . . . . . . . . .323,334
CBR1.5M-M  . . . . . . . . . . . . . . . .323,334
CBR1M-M  . . . . . . . . . . . . . . . . .323,334
CBR2HS-D . . . . . . . . . . . . . . . . .323,334
CBR2M-M  . . . . . . . . . . . . . . . . .323,334
CBR2S-M  . . . . . . . . . . . . . . . . . .323,334
CBR3I-M  . . . . . . . . . . . . . . . . . .323,334
CBR3S-M  . . . . . . . . . . . . . . . . . .323,334
CBR4I-M  . . . . . . . . . . . . . . . . . .323,334
CBR4LH-TL  . . . . . . . . . . . . . . . .323,334
CBR4S-M  . . . . . . . . . . . . . . . . . .323,334
CBR6LH-C  . . . . . . . . . . . . . . . . . . . .324
CBR6LH-TL . . . . . . . . . . . . . . . . . . . .323
CBUK  . . . . . . . . . . . . . . . . . . . . . . . . .32
CBUK-2G  . . . . . . . . . . . . . . . . . . . . . .32
CBUKAW . . . . . . . . . . . . . . . . . . . . . . .32
CBUKAW-2G . . . . . . . . . . . . . . . . . . . .32
CBUKIW  . . . . . . . . . . . . . . . . . . . . . . .32
CBUKIW-2G  . . . . . . . . . . . . . . . . . . . .32
CBUKWH-2G  . . . . . . . . . . . . . . . . . . .32
CBX1 . . . . . . . . . . . . . . . . . . . . . . . . . .42
CBX12AW-A  . . . . . . . . . . . . . . . . . . . .43
CBX2 . . . . . . . . . . . . . . . . . . . . . . . . . .42
CBX2AW-A  . . . . . . . . . . . . . . . . . . . . .42
CBX4 . . . . . . . . . . . . . . . . . . . . . . . . . .42
CBXC4  . . . . . . . . . . . . . . . . . . . . . . . .42
CBXC4AW-A  . . . . . . . . . . . . . . . . . . . .42
CBXD6AW-A  . . . . . . . . . . . . . . . . . . . .43
CBXF12AW-A  . . . . . . . . . . . . . . . . . . .43
CBXF6AW-A  . . . . . . . . . . . . . . . . . . . .43
CBXF6KITAW-A  . . . . . . . . . . . . . . . . .43
CBXJ2  . . . . . . . . . . . . . . . . . . . . . . . . .42
CBXJ2AW-A  . . . . . . . . . . . . . . . . . . . .42
CBXS1IW-A  . . . . . . . . . . . . . . . . . . . .41
CBXS2IW-A  . . . . . . . . . . . . . . . . . . . .41
CBXS3IW-A  . . . . . . . . . . . . . . . . . . . .41
CBXS4IW-A  . . . . . . . . . . . . . . . . . . . .41
CBXS6IW-A  . . . . . . . . . . . . . . . . . . . .41
CBXSD6IW-A  . . . . . . . . . . . . . . . . . . .41
CC-720    . . . . . . . . . . . . . . . . . . . . . .186
CCMKIT1  . . . . . . . . . . . . . . . . . . . . .146
CCMKIT2  . . . . . . . . . . . . . . . . . . . . .146
CD-720-1    . . . . . . . . . . . . . . . . . . . .186
CD-720-2    . . . . . . . . . . . . . . . . . . . .186
CD-720-3    . . . . . . . . . . . . . . . . . . . .186
CD-720-4    . . . . . . . . . . . . . . . . . . . .186
CD-720-5    . . . . . . . . . . . . . . . . . . . .186
CD-720-6    . . . . . . . . . . . . . . . . . . . .186
CD-720-7    . . . . . . . . . . . . . . . . . . . .186
CD-720PV8-2    . . . . . . . . . . . . . . . . .186
CD-920-1    . . . . . . . . . . . . . . . . . . . .188
CD-920-1/0    . . . . . . . . . . . . . . . . . . .188
CD-920-2    . . . . . . . . . . . . . . . . . . . .188
CD-920-2/0    . . . . . . . . . . . . . . . . . . .188
CD-920-250    . . . . . . . . . . . . . . . . . .188
CD-920-3/0    . . . . . . . . . . . . . . . . . . .188
CD-920-300    . . . . . . . . . . . . . . . . . .188
CD-920-350    . . . . . . . . . . . . . . . . . .188
CD-920-4    . . . . . . . . . . . . . . . . . . . .188
CD-920-4/0    . . . . . . . . . . . . . . . . . . .188
CD-920-400    . . . . . . . . . . . . . . . . . .188
CD-920-500    . . . . . . . . . . . . . . . . . .188
CD-920-500A

 . . . . . . . . . . . . . . . . .188

CD-920-6   . . . . . . . . . . . . . . . . . . . . .188

Panduit-Pannet-html.html
background image

390

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

390

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

CD-920-600    . . . . . . . . . . . . . . . . . .188
CD-920-750    . . . . . . . . . . . . . . . . . .188
CD-920-8    . . . . . . . . . . . . . . . . . . . .188
CD-FCRP5  . . . . . . . . . . . . . . . . .106,107
CES3AW  . . . . . . . . . . . . . . . . . . . . . . .38
CF10IW-E    . . . . . . . . . . . . . . . . . . . .317
CF3IW-E    . . . . . . . . . . . . . . . . . . . . .317
CF5IW-E    . . . . . . . . . . . . . . . . . . . . .317
CFAPPBL1  . . . . . . . . . . . . . . .15,17,112
CFAPPBL2  . . . . . . . . . . . . . . . . . .15,112
CFFP4BL  . . . . . . . . . . . . . . . . . . . . . .40
CFFPA2BL  . . . . . . . . . . . . . . . . . . . . .40
CFFPEBSL4BL  . . . . . . . . . . . . . . . . . .40
CFFPHM4BL . . . . . . . . . . . . . . . . . . . .40
CFFPL4BL  . . . . . . . . . . . . . . . . . . . . .40
CFP6AS9SBL  . . . . . . . . . . . . . . . . . . .34
CFPAGF2  . . . . . . . . . . . . . . . . . . . . . .33
CFPAGF2AW  . . . . . . . . . . . . . . . . . . .33
CFPAGF2IW  . . . . . . . . . . . . . . . . . . . .33
CFPAGF2PW  . . . . . . . . . . . . . . . . . . .33
CFPAGS2AW  . . . . . . . . . . . . . . . . . . .33
CFPAGS2IW  . . . . . . . . . . . . . . . . . . . .33
CFPAGS2PW  . . . . . . . . . . . . . . . . . . .33
CFPAGS2SAW  . . . . . . . . . . . . . . . . . .33
CFPAGS2SIW  . . . . . . . . . . . . . . . . . . .33
CFPAGS2SPW  . . . . . . . . . . . . . . . . . .33
CFPCH3AW  . . . . . . . . . . . . . . . . . . . .37
CFPDS2  . . . . . . . . . . . . . . . . . . . . . . .37
CFPDS2S  . . . . . . . . . . . . . . . . . . . . . .37
CFPDS2SEW . . . . . . . . . . . . . . . . . .8,10
CFPDS2SG . . . . . . . . . . . . . . . . . . . . .37
CFPDS2SSG  . . . . . . . . . . . . . . . . . . .37
CFPDS2SWH  . . . . . . . . . . . . . . . . . . .37
CFPDS2WH  . . . . . . . . . . . . . . . . . . . .37
CFPE3 . . . . . . . . . . . . . . . . . . . . . . . . .33
CFPE3AW  . . . . . . . . . . . . . . . . . . . . . .33
CFPE3IW  . . . . . . . . . . . . . . . . . . . . . .33
CFPE3PW . . . . . . . . . . . . . . . . . . . . . .33
CFPFF2 . . . . . . . . . . . . . . . . . . . . . . . .35
CFPFF2AW  . . . . . . . . . . . . . . . . . . . . .35
CFPFS1SAW  . . . . . . . . . . . . . . . . . . .35
CFPFS2AW . . . . . . . . . . . . . . . . . . . . .35
CFPFS2SAW  . . . . . . . . . . . . . . .8,10,35
CFPGAS3SBL . . . . . . . . . . . . . . . . . . .34
CFPGAS6SBL . . . . . . . . . . . . . . . . . . .34
CFPGFB3  . . . . . . . . . . . . . . . . . . . . . .34
CFPGFB3BL  . . . . . . . . . . . . . . . . . . . .34
CFPH2  . . . . . . . . . . . . . . . . . . . . . . . .36
CFPH2AW . . . . . . . . . . . . . . . . . . . . . .36
CFPH2BL  . . . . . . . . . . . . . . . . . . . . . .36
CFPH2IW  . . . . . . . . . . . . . . . . . . . . . .36
CFPH2WH  . . . . . . . . . . . . . . . . . . . . .36
CFPH4  . . . . . . . . . . . . . . . . . . . . . . . .36
CFPH4AW . . . . . . . . . . . . . . . . . . . . . .36
CFPH4AW . . . . . . . . . . . . . . . . . . . . . .36
CFPH4BL  . . . . . . . . . . . . . . . . . . . . . .36
CFPH4IW  . . . . . . . . . . . . . . . . . .8,10,36
CFPH4WH  . . . . . . . . . . . . . . . . . . . . .36
CFPHS2  . . . . . . . . . . . . . . . . . . . . . . .36
CFPHSL4AIW  . . . . . . . . . . . . . . . . . . .36
CFPHSL4AW  . . . . . . . . . . . . . . . . . . .36
CFPHSL4AW  . . . . . . . . . . . . . . . . . . .36
CFPTS4  . . . . . . . . . . . . . . . . . . . . . . .38
CFPTS4AW . . . . . . . . . . . . . . . . . . . . .38
CFPTS4EW . . . . . . . . . . . . . . . . . . . . .38
CFPUKS2B  . . . . . . . . . . . . . . . . . . . . .32
CFPUKS2BAW  . . . . . . . . . . . . . . . . . .32
CFPUKS2BIW . . . . . . . . . . . . . . . . . . .32

CFPUKS2BWH  . . . . . . . . . . . . . . . . . .32
CFPUKS2S  . . . . . . . . . . . . . . . . . . . . .32
CFPUKS2SAW  . . . . . . . . . . . . . . . . . .32
CFPUKS2SIW . . . . . . . . . . . . . . . . . . .32
CFPUKS2SWH  . . . . . . . . . . . . . .8,10,32
CFPUKS3  . . . . . . . . . . . . . . . . . . . . . .32
CFPUKS3AW  . . . . . . . . . . . . . . . . . . .32
CFPUKS3IW  . . . . . . . . . . . . . . . . . . . .32
CFPUKS4S-2G  . . . . . . . . . . . . . . . . . .32
CFPUKS4SAW-2G  . . . . . . . . . . . . . . .32
CFS2AW  . . . . . . . . . . . . . . . . . . . .40,42
CFS2BL . . . . . . . . . . . . . . . . . . . . . . . .40
CFS2IW . . . . . . . . . . . . . . . . . . . . . . . .40
CFS2WH  . . . . . . . . . . . . . . . . . . . . . . .40
CFTSL4AW  . . . . . . . . . . . . . . . . . . . . .38
CFTSL4EW  . . . . . . . . . . . . . . . . . . . . .38
CFX10IW-X    . . . . . . . . . . . . . . .318,319
CFX3IW-X    . . . . . . . . . . . . . . . .318,319
CFX5IW-X    . . . . . . . . . . . . . . . .318,319
CGAGY-X  . . . . . . . . . . . . . . . . . . . . . .36
CGJT . . . . . . . . . . . . . . . . . . . . .22,30,57
CGVA2BL  . . . . . . . . . . . . . . . . . . . . . .38
CH105-A-C14  . . . . . . . . . . . . . . . . . .341
CH105-S6-C14  . . . . . . . . . . . . . . . . .341
CHES3  . . . . . . . . . . . . . . . . . . . . . . . .35
CHES3AW . . . . . . . . . . . . . . . . . .8,10,35
CHES3IW  . . . . . . . . . . . . . . . . . . . . . .35
CHES3PW  . . . . . . . . . . . . . . . . . . . . .35
CHF2 . . . . . . . . . . . . . . . . . . . . . . . . . .39
CHF2AW-X  . . . . . . . . . . . . . . . . . . . . .39
CHF2BL-X . . . . . . . . . . . . . . . . . . . . . .39
CHF2IW-X  . . . . . . . . . . . . . . . . . . . . . .39
CHF2M  . . . . . . . . . . . . . . . . . . . . . . . .39
CHF2MAW-X . . . . . . . . . . . . . . . . . . . .39
CHF2MBL-X  . . . . . . . . . . . . . . . . . . . .39
CHF2MIW-X  . . . . . . . . . . . . . . . . . . . .39
CHF2MPW-X  . . . . . . . . . . . . . . . . . . .39
CHF2MWH-X  . . . . . . . . . . . . . . . . . . .39
CHF2PW-X  . . . . . . . . . . . . . . . . . . . . .39
CHF2WH-X  . . . . . . . . . . . . . . . . . . . . .39
CHLK66S2S  . . . . . . . . . . . . . . . . . . . .37
CHLKCLS2S  . . . . . . . . . . . . . . . . . . . .37
CHS2 . . . . . . . . . . . . . . . . . . . . . . . . . .39
CHS2AW-X  . . . . . . . . . . . . . . . . . . . . .39
CHS2BL-X . . . . . . . . . . . . . . . . . . . . . .39
CHS2IW-X . . . . . . . . . . . . . . . . . . . . . .39
CHS2PW-X  . . . . . . . . . . . . . . . . . . . . .39
CHS2R  . . . . . . . . . . . . . . . . . . . . . . . .39
CHS2S  . . . . . . . . . . . . . . . . . . . . . . . .39
CHS2SAW-X  . . . . . . . . . . . . . . . . . . . .39
CHS2SBL-X  . . . . . . . . . . . . . . . . . . . .39
CHS2SIW-X  . . . . . . . . . . . . . . . . . . . .39
CHS2SWH-X . . . . . . . . . . . . . . . . . . . .39
CHS2WH-X  . . . . . . . . . . . . . . . . . . . . .39
CHSR2AW-X . . . . . . . . . . . . . . . . . . . .39
CHSR2BL-X  . . . . . . . . . . . . . . . . . . . .39
CHSR2IW-X  . . . . . . . . . . . . . . . . . . . .39
CHSR2PW-X . . . . . . . . . . . . . . . . . . . .39
CHSR2WH-X  . . . . . . . . . . . . . . . . . . .39
CICZC2X2 . . . . . . . . . . . . . . . . . . . . . .49
CICZC2X2A  . . . . . . . . . . . . . . . . . . . .49
CICZCBRKT  . . . . . . . . . . . . . . . . . . . .49
CIFP1S  . . . . . . . . . . . . . . . . . . . . . . . .24
CIFP2S-2G  . . . . . . . . . . . . . . . . . . . . .24
CIFZC11  . . . . . . . . . . . . . . . . . . . . . . .49
CIFZC4  . . . . . . . . . . . . . . . . . . . . . . . .49
CIFZC8  . . . . . . . . . . . . . . . . . . . . . . . .49
CJ5E88TGAW . . . . . . . . . . . . . . . . . . . .8

CJ5E88TGIW  . . . . . . . . . . . . . . . . . . .20
CJ64AW  . . . . . . . . . . . . . . . . . . . . . . .25
CJ66AW  . . . . . . . . . . . . . . . . . . . . . . .25
CJ688TG . . . . . . . . . . . . . . . . . . . . . . .10
CJ688TGIW  . . . . . . . . . . . . . . . . . . . .20
CJ6X88TG . . . . . . . . . . . . . . . . . . . . . .11
CJ88AW  . . . . . . . . . . . . . . . . . . . . . . .25
CJAST  . . . . . . . . . . . . . . . . . . . . . .30,57
CJI5E88T  . . . . . . . . . . . . . . . . . . . . . .22
CJRRIW  . . . . . . . . . . . . . . . . . . . . . . .26
CJRWIW  . . . . . . . . . . . . . . . . . . . . . . .26
CJRYIW  . . . . . . . . . . . . . . . . . . . . . . .26
CJS5E88TG  . . . . . . . . . . . . . . . . . . .9,20
CJS688TG  . . . . . . . . . . . . . . . . . . .11,20
CJS6X88TG  . . . . . . . . . . . . . . . . . . . .13
CJSGK-X    . . . . . . . . . . . . . . . . . . . .162
CJSI5E88T  . . . . . . . . . . . . . . . . . . . . .22
CJSVIW . . . . . . . . . . . . . . . . . . . . . . . .27
CJT-X  . . . . . . . . . . . . . . . . . . . . . . .30,57
CLRCVR1-1    . . . . . . . . . . . . . . . . . .181
CLRCVR2-1    . . . . . . . . . . . . . . . . . .181
CLRCVR3-1    . . . . . . . . . . . . . . . . . .181
CLRCVR4-1    . . . . . . . . . . . . . . . . . .181
CLT100F-C20  . . . . . . . . . . . . . . . . . .346
CLT100F-C3  . . . . . . . . . . . . . . . . . . .346
CLT125F-L20  . . . . . . . . . . . . . . . . . .346
CLT125F-L3  . . . . . . . . . . . . . . . . . . .346
CLT150F-T20  . . . . . . . . . . . . . . . . . .346
CLT150F-X20  . . . . . . . . . . . . . . . . . .346
CLT150F-X3  . . . . . . . . . . . . . . . . . . .346
CLT150F-X4  . . . . . . . . . . . . . . . . . . .346
CLT188F-X3  . . . . . . . . . . . . . . . . . . .346
CLT188F-X4  . . . . . . . . . . . . . . . . . . .346
CLT25F-C20  . . . . . . . . . . . . . . . . . . .346
CLT25F-C3  . . . . . . . . . . . . . . . . . . . .346
CLT38F-C20  . . . . . . . . . . . . . . . . . . .346
CLT38F-C3  . . . . . . . . . . . . . . . . . . . .346
CLT50F-C20  . . . . . . . . . . . . . . . . . . .346
CLT50F-C3  . . . . . . . . . . . . . . . . . . . .346
CLT75F-C20  . . . . . . . . . . . . . . . . . . .346
CLT75F-C3  . . . . . . . . . . . . . . . . . . . .346
CLTS100F-C  . . . . . . . . . . . . . . . . . . .346
CLTS100F-C3  . . . . . . . . . . . . . . . . . .346
CLTS125F-L  . . . . . . . . . . . . . . . . . . .346
CLTS125F-L3  . . . . . . . . . . . . . . . . . .346
CLTS25F-C  . . . . . . . . . . . . . . . . . . . .346
CLTS25F-C3  . . . . . . . . . . . . . . . . . . .346
CLTS38F-C  . . . . . . . . . . . . . . . . . . . .346
CLTS38F-C3  . . . . . . . . . . . . . . . . . . .346
CLTS50F-C  . . . . . . . . . . . . . . . . . . . .346
CLTS50F-C3  . . . . . . . . . . . . . . . . . . .346
CLTS75F-C  . . . . . . . . . . . . . . . . . . . .346
CLTS75F-C3  . . . . . . . . . . . . . . . . . . .346
CM35MSSIW  . . . . . . . . . . . . . . . . . . .25
CM6CAW  . . . . . . . . . . . . . . . . . . . . . .33
CM6CAW-X . . . . . . . . . . . . . . . . . . . . .33
CM6CESAW  . . . . . . . . . . . . . . . . . . . .33
CM6CESAW-X  . . . . . . . . . . . . . . . . . .33
CM6CSAW  . . . . . . . . . . . . . . . . . . . . .33
CM6CSAW-X  . . . . . . . . . . . . . . . . . . .33
CMBA  . . . . . . . . . . . . . . . . . . . . . . . . .16
CMBA75AW  . . . . . . . . . . . . . . . . . . . .26
CMBAAW  . . . . . . . . . . . . . . . . . . . . . .26
CMBAW-X  . . . . . . . . . . . . . . . . . . . . .105
CMBIW-X  . . . . . . . . . . . . . . . . . . . .16,30
CMBPBI  . . . . . . . . . . . . . . . . . . . . . . .25
CMBPBIW  . . . . . . . . . . . . . . . . . . . . . .25
CMBPRIW . . . . . . . . . . . . . . . . . . . . . .25

Panduit-Pannet-html.html
background image

391

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

CMBRC1  . . . . . . . . . . . . . . . . . . . . . .151
CMBRC1E . . . . . . . . . . . . . . . . . . . . .151
CMBRC5  . . . . . . . . . . . . . . . . . . . . . .151
CMBRC5E . . . . . . . . . . . . . . . . . . . . .151
CMDAGSCZBL  . . . . . . . . . . . . . . . . .115
CMDBAW-X  . . . . . . . . . . . . . . . . . . . .27
CMDBUSC  . . . . . . . . . . . . . . . . . . . . .16
CMDBUSCZ  . . . . . . . . . . . . . . . . . . . .14
CMDBUSCZBU . . . . . . . . . . . . . . . . . .96
CMDEISC  . . . . . . . . . . . . . . . . . . . . . .16
CMDEISCAW  . . . . . . . . . . . . . . . . . .104
CMDJAQLCZBL  . . . . . . . . . . . . . . . . .28
CMDJLC  . . . . . . . . . . . . . . . . . . . . . . .16
CMDJLCZ  . . . . . . . . . . . . . . . . . . . . . .14
CMDJLCZ  . . . . . . . . . . . . . . . . . . . . . .14
CMDJLCZBU  . . . . . . . . . . . . . . . .28,104
CMDRH1 . . . . . . . . . . . . . . . . . . . . . .150
CMDRH2 . . . . . . . . . . . . . . . . . . . . . .150
CMDRHD1  . . . . . . . . . . . . . . . . . . . .150
CMDRHD2  . . . . . . . . . . . . . . . . . . . .150
CMDSLC  . . . . . . . . . . . . . . . . . . . . . . .16
CMDSLCAW  . . . . . . . . . . . . . . . . . . . .98
CMDSLCZ . . . . . . . . . . . . . . . . . . . . . .14
CMDSLCZBU  . . . . . . . . . . . . . . . . . . .98
CMFBAAW  . . . . . . . . . . . . . . . . . . . . .26
CMFC  . . . . . . . . . . . . . . . . . . . . . . . . .16
CMFCEI  . . . . . . . . . . . . . . . . . . . . . .105
CMFCZ  . . . . . . . . . . . . . . . . . . . . . . . .14
CMFCZBU  . . . . . . . . . . . . . . . . . .29,105
CMFSR  . . . . . . . . . . . . . . . . . . . . . . . .16
CMFSRAW  . . . . . . . . . . . . . . . . . . . . .26
CMLT19 . . . . . . . . . . . . . . . . . . . . . . .142
CMMJ  . . . . . . . . . . . . . . . . . . . . . . . . .14
CMMJEI  . . . . . . . . . . . . . . . . . . . .28,104
CMPH1  . . . . . . . . . . . . . . . . . . . . . . .149
CMPH123  . . . . . . . . . . . . . . . . . . . . .149
CMPH1C  . . . . . . . . . . . . . . . . . . . . . .149
CMPH1W  . . . . . . . . . . . . . . . . . . . . .149
CMPH2  . . . . . . . . . . . . . . . . . . . . . . .149
CMPH223  . . . . . . . . . . . . . . . . . . . . .149
CMPH2C  . . . . . . . . . . . . . . . . . . . . . .149
CMPH2W  . . . . . . . . . . . . . . . . . . . . .149
CMPHF1  . . . . . . . . . . . . . . . . . . . . . .149
CMPHF123  . . . . . . . . . . . . . . . . . . . .149
CMPHF2  . . . . . . . . . . . . . . . . . . . . . .149
CMPHF223  . . . . . . . . . . . . . . . . . . . .149
CMPHH2  . . . . . . . . . . . . . . . . . . . . . .149
CMPHHF1 . . . . . . . . . . . . . . . . . . . . .149
CMR19X26  . . . . . . . . . . . . . . . . . . . .142
CMR19X47  . . . . . . . . . . . . . . . . . . . .142
CMR19X84  . . . . . . . . . . . . . . . . . . . .142
CMR19X84    . . . . . . . . . . . . . . . . . . .137
CMR19X84S  . . . . . . . . . . . . . . . . . . .142
CMR23X84  . . . . . . . . . . . . . . . . . . . .142
CMRPRAW  . . . . . . . . . . . . . . . . . . . . .27
CMRPWAW . . . . . . . . . . . . . . . . . . . . .27
CMRPYAW  . . . . . . . . . . . . . . . . . . . . .27
CMSAGSCZBL  . . . . . . . . . . . . . . . . .115
CMSBUSCZ  . . . . . . . . . . . . . . . . . . . .14
CMSBUSCZBU  . . . . . . . . . . . . . . . . . .96
CMSEISC  . . . . . . . . . . . . . . . . . . . . . .16
CMSEISCAW  . . . . . . . . . . . . . . . . . . .96
CMSRC2  . . . . . . . . . . . . . . . . . . . . . .151
CMSTAW . . . . . . . . . . . . . . . . . . . . . . .92
CMSTZ  . . . . . . . . . . . . . . . . . . . . . . . .14
CMSTZBU . . . . . . . . . . . . . . . . . . . . . .92
CMSVCAW  . . . . . . . . . . . . . . . . . . . . .27
CMT4    . . . . . . . . . . . . . . . . . . . . . . .142

CMUT19  . . . . . . . . . . . . . . . . . . . . . .142
CMVDR1  . . . . . . . . . . . . . . . . . . . . . .150
CMVDR1-8  . . . . . . . . . . . . . . . . . . . .134
CMVDR1S . . . . . . . . . . . . . . . . . . . . .150
CMVDR2  . . . . . . . . . . . . . . . . . . . . . .150
CMVDR2S . . . . . . . . . . . . . . . . . . . . .150
CMVDRC  . . . . . . . . . . . . . . . . . . . . .150
CMWB . . . . . . . . . . . . . . . . . . . . . . . .152
CMW-KIT  . . . . . . . . . . . . . . . . . . . . .152
CMWW  . . . . . . . . . . . . . . . . . . . . . . .152
CP16BL  . . . . . . . . . . . . . . . . .9,11,13,62
CP16WSBL  . . . . . . . . . . . . . . . . . .26,62
CP24BL  . . . . . . . . . . . . . . . . . . . . .13,62
CP24WSBL  . . . . . . . . . . . . . . . . 9,11,62
CP48BL  . . . . . . . . . . . . . . . . . . . . .13,62
CP48BNCBL  . . . . . . . . . . . . . . . . . 30,66
CP48WSBL  . . . . . . . . . . . . . . . . . . 26,62
CP72BL  . . . . . . . . . . . . . . . . . . . . .13,62
CP96BL  . . . . . . . . . . . . . . . . . . . . .13,62
CPAF1BL

 . . . . . . . . . . . . . . . . . . . .145

CPAF2BL

 . . . . . . . . . . . . . . . . . . . .145

CPG    . . . . . . . . . . . . . . . . . . . . . . . .263
CPKC24BL  . . . . . . . . . . . . . . . . . . . . .66
CPP12WBL  . . . . . . . . . . . . . . . . . . . . .61
CPP24WBL  . . . . . . . . . . . 9,10,11,57,58
CPP48HDWBL  . . . . . . . . . . . . . . . . . .59
CPP48WBL  . . . . . . . . . . . . . . . . . . 57,58
CPPA24FMWBL  . . . . . . . . . . . . . . . . .59
CPPA48FMWBL  . . . . . . . . . . . . . . . . .59
CPPA48HDWBL  . . . . . . . . . . . . . . . . .60
CPPL24M6BL  . . . . . . . . . . . . . . . .58,57
CPPL24WBL  . . . . . . . . . . . . . . 12,57,58
CPPL24WRBL  . . . . . . . . . . . . . . . . . .61
CPPL48M6BL  . . . . . . . . . . . . . . . . . . .58
CPPL48WBL  . . . . . . . . . . . . . . .12,57,58
CPPL48WRBL  . . . . . . . . . . . . . . . . . .61
CPPL72WBL  . . . . . . . . . . . . . . . . . . . .59
CPPLA24WBL . . . . . . . . . . . . . . . . . . .60
CPPLA48WBL . . . . . . . . . . . . . . . . . . .60
CPPLA48WBL  . . . . . . . . . . . . . . . . .137
CPPLA72WBL . . . . . . . . . . . . . . . . . . .60
CRFC5IW-X    . . . . . . . . . . . . . . .317,318
CRFX5IW-X    . . . . . . . . . . . . . . . . . .319
CRS1-125-X . . . . . . . . . . . . . . . .139,152
CRS1-X  . . . . . . . . . . . . . . . . . . . . . . .152
CRS4-125-X . . . . . . . . . . . . . . . .139,152
CRS6-X  . . . . . . . . . . . . . . . . . . . . . . .152
CRTW    . . . . . . . . . . . . . . . . . . . . . . .142
CS2FP . . . . . . . . . . . . . . . . . . . . . . . . .35
CS2FPAW  . . . . . . . . . . . . . . . . . . . . . .35
CSC1LG6  . . . . . . . . . . . . . . . . . . . . .249
CSPC1.5LG-Q  . . . . . . . . . . . . . . . . .249
CSPC1LG-Q  . . . . . . . . . . . . . . . . . . .249
CSPC2LG-Q  . . . . . . . . . . . . . . . . . . .249
CSPC3LG-Q  . . . . . . . . . . . . . . . . . . .249
CSPC4LG-Q  . . . . . . . . . . . . . . . . . . .249
CST115  . . . . . . . . . . . .106,107,108,109
CT-1550    . . . . . . . . . . . . . . . . . . . . .187
CT-1551    . . . . . . . . . . . . . . . . . . . . .187
CT-1570    . . . . . . . . . . . . . . . . . . . . .187
CT-1700    . . . . . . . . . . . . . . . . . . . . .187
CT-1701    . . . . . . . . . . . . . . . . . . . . .187
CT-720    . . . . . . . . . . . . . . . . . . . . . .186
CT-720    . . . . . . . . . . . . . . . . . . . . . .187
CT-720-3    . . . . . . . . . . . . . . . . . . . . .187
CT-720-3CC    . . . . . . . . . . . . . . . . . .187
CT-720-7    . . . . . . . . . . . . . . . . . . . . .187
CT-720-7    . . . . . . . . . . . . . . . . . . . . .187

CT-720-7CC    . . . . . . . . . . . . . . . . . .187
CT-930    . . . . . . . . . . . . . . . . . . . . . .188
CT-980    . . . . . . . . . . . . . . . . . . . . . .189
CTAP2/0-2-X    . . . . . . . . . . . . . . . . . .180
CTAP2/0-2-X    . . . . . . . . . . . . . . . . . .180
CTAP2-2-X    . . . . . . . . . . . . . . . . . . .180
CTAP2-4-Q    . . . . . . . . . . . . . . . . . . .180
CTAP4/0-2/0-X    . . . . . . . . . . . . . . . .180
CTAP4/0-2-X    . . . . . . . . . . . . . . . . . .180
CTAP4/0-4/0-X    . . . . . . . . . . . . . . . .180
CTAP4-4-L

 . . . . . . . . . . . . . . . . . . .180

CTAP4-6-L

 . . . . . . . . . . . . . . . . . . .180

CTAP4-8-L

 . . . . . . . . . . . . . . . . . . .180

CTAPF1/0-12-L  . . . . . . . . . . . . . . . .180
CTAPF10-16-C    . . . . . . . . . . . . . . . .180
CTAPF1-12-C    . . . . . . . . . . . . . . . . .180
CTAPF2/0-12-Q    . . . . . . . . . . . . . . .180
CTAPF2-12-C    . . . . . . . . . . . . . . . . .180
CTAPF3/0-12-Q    . . . . . . . . . . . . . . .180
CTAPF3-12-C    . . . . . . . . . . . . . . . . .180
CTAPF4-12-C    . . . . . . . . . . . . . . . . .180
CTAPF6-12-C    . . . . . . . . . . . . . . . . .180
CTAPF8-12-C    . . . . . . . . . . . . . . . . .180
CUFB48BL  . . . . . . . . . . . . . . . . . . . . .48
CUFF-KIT  . . . . . . . . . . . . . . . . . . . . . .48
CUFMB24BL  . . . . . . . . . . . . . . . . . . . .48
CVIA1GY-X  . . . . . . . . . . . . . . . . . . . . .36
CVIA1WH-X  . . . . . . . . . . . . . . . . . . . .36
CWMPH1  . . . . . . . . . . . . . . . . . . . . .146
CWMPHF1  . . . . . . . . . . . . . . . . . . . .146
CWMPV2318  . . . . . . . . . . . . . . . . . .146
CWMPV2340  . . . . . . . . . . . . . . . . . .146
CWMPV2418  . . . . . . . . . . . . . . . . . .146
CWMPV2440  . . . . . . . . . . . . . . . . . .146
CWMPV3318  . . . . . . . . . . . . . . . . . .146
CWMPV3340  . . . . . . . . . . . . . . . . . .146
CWMPV3418  . . . . . . . . . . . . . . . . . .146
CWMPV3440  . . . . . . . . . . . . . . . . . .146
CWPP12WBL  . . . . . . . . . . . . . . . . . . .61
CWST . . . . . . . . . . . . . . . . . . . . . . .30,57

D

D1H6  . . . . . . . . . . . . . . . . . . . . . . . . .248
D1.5H6  . . . . . . . . . . . . . . . . . . . . . . .248
D2H6  . . . . . . . . . . . . . . . . . . . . . . . . .248
D3H6  . . . . . . . . . . . . . . . . . . . . . . . . .248
D4H6  . . . . . . . . . . . . . . . . . . . . . . . . .248
DB-C  . . . . . . . . . . . . . . . . . . . . . . . . .248
DCEFXIW-X  . . . . . . . . . . . . . . . .318,319
DCF10IW-X  . . . . . . . . . . . . . . . . . . . .317
DCF3IW-X  . . . . . . . . . . . . . . . . . . . . .317
DCF5IW-X  . . . . . . . . . . . . . . . . . . . . .317
DCT . . . . . . . . . . . . . . . . . . . . . . . . . .248
DCT-BLD . . . . . . . . . . . . . . . . . . . . . .248
DCT-RI  . . . . . . . . . . . . . . . . . . . . . . .248
DFCT . . . . . . . . . . . . . . . . . . . . . . . . .248
DNT-100  . . . . . . . . . . . . . . . . . . . . . .248
DP125E88TG  . . . . . . . . . . . . . . . . . . .64
DP12688TG  . . . . . . . . . . . . . . . . . . . .63
DP24584TV25  . . . . . . . . . . . . . . . .64,65
DP245E88TG . . . . . . . . . . . . . . . . . .8,64
DP24688TG  . . . . . . . . . . . . . . . . . . . .10
DP24688TG  . . . . . . . . . . . . . . . . . . . .63
DP246X88TG  . . . . . . . . . . . . . . . . . . .12
DP48584TV25  . . . . . . . . . . . . . . . .64,65
DP485E88TG  . . . . . . . . . . . . . . . . . . .64
DP48688TG  . . . . . . . . . . . . . . . . . . . .63
DP486X88TG  . . . . . . . . . . . . . . . . . . .12

Panduit-Pannet-html.html
background image

392

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

392

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

DP486X88TG  . . . . . . . . . . . . . . . . . . .63
DPA245E88TG  . . . . . . . . . . . . . . . . . .64
DPA24688TG  . . . . . . . . . . . . . . . . . . .63
DPA246X88TG  . . . . . . . . . . . . . . . . . .12
DPA246X88TG  . . . . . . . . . . . . . . . . . .63
DPA485E88TG  . . . . . . . . . . . . . . . . . .64
DPA48688TG  . . . . . . . . . . . . . . . . . . .63
DPA486X88TG  . . . . . . . . . . . . . . . . . .12
DPA486X88TG  . . . . . . . . . . . . . . . . . .63
DPFP1 . . . . . . . . . . . . . . . . . . . . . . . .144
DPFP2 . . . . . . . . . . . . . . . . . . . . . . . .144
DPFP4 . . . . . . . . . . . . . . . . . . . . . . . .144
DPFP8 . . . . . . . . . . . . . . . . . . . . . . . .144
DPOE24U1X  . . . . . . . . . . . . . . . . . . . .56
DPOEPWRCM  . . . . . . . . . . . . . . . . . .56
DPOEPWRCU  . . . . . . . . . . . . . . . . . .56
DPOEPWRNIC  . . . . . . . . . . . . . . . . . .56
DPOEPWRR1250  . . . . . . . . . . . . . . . .56
DPOEPWRR500  . . . . . . . . . . . . . . . . .56
DR84  . . . . . . . . . . . . . . . . . . . . . . . . .134
DRD284  . . . . . . . . . . . . . . . . . . . . . .134
DT4EH-L  . . . . . . . . . . . . . . . . . . . . . .333
DT4EH-L0  . . . . . . . . . . . . . . . . . . . . .329
DT8EH-Q  . . . . . . . . . . . . . . . . . . . . .333
DT8EH-Q0  . . . . . . . . . . . . . . . . . . . .329
DTHEH-0 . . . . . . . . . . . . . . . . . . . . . .329
DTHEH-Q  . . . . . . . . . . . . . . . . . . . . .333
DTHEH-Q0  . . . . . . . . . . . . . . . . . . . .329
DTREH-LR  . . . . . . . . . . . . . . . . . . . .333
DTREH-LR0  . . . . . . . . . . . . . . . . . . .329

E

E2X2YL6  . . . . . . . . . . . . . . . . . . . . . .236
E4X4YL6  . . . . . . . . . . . . . . . . . . . . . .236
ECF10IW-X  . . . . . . . . . . . . . . . . . . . .317
ECF3IW-E  . . . . . . . . . . . . . . . . . . . . .317
ECF5IW-E  . . . . . . . . . . . . . . . . . . . . .317
ECFX10IW-X . . . . . . . . . . . .313,318,319
ECFX3IW-X  . . . . . . . . . . . . . . . .318,319
ECFX5IW-X  . . . . . . . . . . . . . . . .318,319
EEFXIW  . . . . . . . . . . . . . . . . . . . . . .313
EGJT  . . . . . . . . . . . . . . . . . . . . . . . . . .30
ERU20 . . . . . . . . . . . . . . . . . . . . . . . .263

F

F.5X.5LG6  . . . . . . . . . . . . . . . . . . . . .244
F.5X1LG6  . . . . . . . . . . . . . . . . . . . . .244
F.75X.75LG6  . . . . . . . . . . . . . . . . . . .244
F.75X1.5LG6  . . . . . . . . . . . . . . . . . . .244
F1.5X1.5LG6 . . . . . . . . . . . . . . . . . . .244
F1.5X1LG6  . . . . . . . . . . . . . . . . . . . .244
F1.5X2LG6  . . . . . . . . . . . . . . . . . . . .244
F1.5X3LG6  . . . . . . . . . . . . . . . . . . . .244
F1.5X4LG6  . . . . . . . . . . . . . . . . . . . .244
F14PN-L  . . . . . . . . . . . . . . . . . . . . . .244
F14PWN-L  . . . . . . . . . . . . . . . . . . . .244
F1X1.5LG6  . . . . . . . . . . . . . . . . . . . .244
F1X1LG6 . . . . . . . . . . . . . . . . . . . . . .244
F1X2LG6 . . . . . . . . . . . . . . . . . . . . . .244
F1X3LG6 . . . . . . . . . . . . . . . . . . . . . .244
F1X4LG6 . . . . . . . . . . . . . . . . . . . . . .244
F250BT-C . . . . . . . . . . . . . . . . . .104,128
F2PCLB12 . . . . . . . . . . . . . .205,214,241
F2PCLB12M  . . . . . . . . . . . .205,214,241
F2PCLB58 . . . . . . . . . . . . . .205,214,241
F2PCLB58M  . . . . . . . . . . . .205,214,241
F2X1.5LG6  . . . . . . . . . . . . . . . . . . . .244
F2X1LG6 . . . . . . . . . . . . . . . . . . . . . .244

F2X2LG6 . . . . . . . . . . . . . . . . . . . . . .244
F2X3LG6 . . . . . . . . . . . . . . . . . . . . . .244
F2X4LG6 . . . . . . . . . . . . . . . . . . . . . .244
F2X5LG6 . . . . . . . . . . . . . . . . . . . . . .244
F3X1LG6 . . . . . . . . . . . . . . . . . . . . . .244
F3X2LG6 . . . . . . . . . . . . . . . . . . . . . .244
F3X3LG6 . . . . . . . . . . . . . . . . . . . . . .244
F3X4LG6 . . . . . . . . . . . . . . . . . . . . . .244
F3X5LG6 . . . . . . . . . . . . . . . . . . . . . .244
F4X2LG6 . . . . . . . . . . . . . . . . . . . . . .244
F4X3LG6 . . . . . . . . . . . . . . . . . . . . . .244
F4X4LG6 . . . . . . . . . . . . . . . . . . . . . .244
F4X5LG6 . . . . . . . . . . . . . . . . . . . . . .244
F612D3-5M1  . . . . . . . . . . . . . . . . . . .122
F612D3-NM1 . . . . . . . . . . . . . . . . . . .121
F612D5-5M1  . . . . . . . . . . . . . . . . . . .122
F64D5-5M1  . . . . . . . . . . . . . . . . . . . .122
F66D2-5M1  . . . . . . . . . . . . . . . . . . . .122
F66D2-NM1 . . . . . . . . . . . . . . . . . . . .121
F66D3-5M1  . . . . . . . . . . . . . . . . . . . .122
F66D5-5M1  . . . . . . . . . . . . . . . . . . . .122
F68D5-5M1  . . . . . . . . . . . . . . . . . . . .122
F68D6J-5M1  . . . . . . . . . . . . . . . . . . .122
F68D6J-NM1 . . . . . . . . . . . . . . . . . . .121
F6B10-NM1  . . . . . . . . . . . . . . . . . . . .119
F6B-2-4JAHBBAA  . . . . . . . . . . . . . . .117
F6B-2-4JAKBBAA  . . . . . . . . . . . . . . .117
F6B3-NM1  . . . . . . . . . . . . . . . . . . . . .119
F6B6J-NM1  . . . . . . . . . . . . . . . . . . . .120
F6D2-2M1  . . . . . . . . . . . . . . . . . . . . .119
F6D2-3M  . . . . . . . . . . . . . . . . . . . . . .120
F6D2-3M1  . . . . . . . . . . . . . . . . . . . . .120
F6D3-3M1  . . . . . . . . . . . . . . . . . . . . .119
F6D6J-NM1  . . . . . . . . . . . . . . . . . . . .119
F6D6P**-3M  . . . . . . . . . . . . . . . . . . .120
F6D6P-2M . . . . . . . . . . . . . . . . . . . . .120
F6D6P-2M1 . . . . . . . . . . . . . . . . . . . .120
F6D6P-3M1 . . . . . . . . . . . . . . . . . . . .120
F6D6P-6PM1 . . . . . . . . . . . . . . . . . . .119
F6D6PQ-3M1  . . . . . . . . . . . . . . . . . .120
F6D6PW-3M1  . . . . . . . . . . . . . . . . . .120
F6D6PX-3M1  . . . . . . . . . . . . . . . . . .120
F6D6PY-3M1 . . . . . . . . . . . . . . . . . . .120
F6D6PZ-3M1 . . . . . . . . . . . . . . . . . . .120
F6E10-10M1  . . . . . . . . . . . . . . . . . . .119
F6E3-10M  . . . . . . . . . . . . . . . . . . . . .120
F6JBP5ZIB10MBL  . . . . . . . . . . . . . . .52
F6JBP5ZIB20MBL  . . . . . . . . . . . . . . .52
F6JBP5ZIB30MBL  . . . . . . . . . . . . . . .52
F6JBP5ZIB3MBL  . . . . . . . . . . . . . . . .52
F6JBP5ZIB5MBL  . . . . . . . . . . . . . . . .52
F6JBP5ZIB7MBL  . . . . . . . . . . . . . . . .52
F6JBP5ZIB8MBL  . . . . . . . . . . . . . . . .52
F6S2-2M1  . . . . . . . . . . . . . . . . . . . . .119
F6S3-3M1  . . . . . . . . . . . . . . . . . . . . .119
F912D3-5M1  . . . . . . . . . . . . . . . . . . .127
F912D3-NM1 . . . . . . . . . . . . . . . . . . .127
F912D5-5M1  . . . . . . . . . . . . . . . . . . .127
F94D5-5M1  . . . . . . . . . . . . . . . . . . . .127
F96D2-5M1  . . . . . . . . . . . . . . . . . . . .127
F96D2-NM1 . . . . . . . . . . . . . . . . . . . .127
F96D3-5M1  . . . . . . . . . . . . . . . . . . . .127
F96D3-NM1 . . . . . . . . . . . . . . . . . . . .127
F96D5-5M1  . . . . . . . . . . . . . . . . . . . .127
F98D5-5M1  . . . . . . . . . . . . . . . . . . . .127
F98D6J-5M1  . . . . . . . . . . . . . . . . . . .127
F98D6J-NM1 . . . . . . . . . . . . . . . . . . .127
F9B10-NM1 . . . . . . . . . . . . . . . . . . . .125

F9B2-NM1 . . . . . . . . . . . . . . . . . . . . .126
F9B3-NM1 . . . . . . . . . . . . . . . . . . . . .125
F9B6J-NM1  . . . . . . . . . . . . . . . . . . . .126
F9D2-2M1  . . . . . . . . . . . . . . . . . . . . .126
F9D2-3M  . . . . . . . . . . . . . . . . . . . . . .126
F9D2-3M1  . . . . . . . . . . . . . . . . . . . . .126
F9D3-3M1  . . . . . . . . . . . . . . . . . . . . .126
F9D6J-NM . . . . . . . . . . . . . . . . . . . . .126
F9D6J-NM1 . . . . . . . . . . . . . . . . . . . .126
F9D6P-3M1 . . . . . . . . . . . . . . . . . . . .126
F9D6P-6PM  . . . . . . . . . . . . . . . . . . .126
F9D6P-6PM1  . . . . . . . . . . . . . . . . . .126
F9E10-10M1  . . . . . . . . . . . . . . . . . . .125
F9E3-10M  . . . . . . . . . . . . . . . . . . . . .126
F9E3-10M1  . . . . . . . . . . . . . . . . . . . .126
F9F10-10M1  . . . . . . . . . . . . . . . . . . .125
F9F10-NM  . . . . . . . . . . . . . . . . .125,126
F9F3-10M  . . . . . . . . . . . . . . . . . . . . .126
F9F3-10M1  . . . . . . . . . . . . . . . . . . . .126
F9S2-2M1  . . . . . . . . . . . . . . . . . . . . .125
F9S2-3M  . . . . . . . . . . . . . . . . . . . . . .126
F9S2-3M1  . . . . . . . . . . . . . . . . . . . . .126
F9S3-3M1  . . . . . . . . . . . . . . . . . . . . .126
FADC4X4  . . . . . . . . . . . . . . . . . . . . .216
FADJLCZBU-L  . . . . . . . . . . . . . . . . . .14
FADSCAQ-L  . . . . . . . . . . . . . . . . . . . .95
FADSCEI-L  . . . . . . . . . . . . . . . . . . . . .95
FADSCZAG-L  . . . . . . . . . . . . . . . . . . .95
FADSCZAQ-L  . . . . . . . . . . . . . . . .95,115
FADSCZBU-L . . . . . . . . . . . . . . . . .14,95
FADSLCEI-L . . . . . . . . . . . . . . . . . .97,98
FADSLCZAQ-L  . . . . . . . . . . . . . . . . . .98
FADSLCZBU-L  . . . . . . . . . . . . .14,97,98
FAF12WAGSCZ  . . . . . . . . . . . . . . 15,17
FALC  . . . . . . . . . . . . . .106,107,108,109
FAP12WBUDLCZ  . . . . . . . . . . . . . . .115
FAP12WBULCZ  . . . . . . . . . . . . . . . .115
FAP2WAGDSCZ  . . . . . . . . . . . . . . . .115
FAP2WAGSCZ  . . . . . . . . . . . . . . . . .115
FAP2WBUDSCZ  . . . . . . . . . . . . . . . .115
FAP2WEIDSC  . . . . . . . . . . . . . . . . . .115
FAP3WAGSCZ  . . . . . . . . . . . . . . . . .115
FAP3WBUDSCZ  . . . . . . . . . . . . . . . .115
FAP3WEIDSC  . . . . . . . . . . . . . . . . . .115
FAP3WEIDSCA  . . . . . . . . . . . . . . . . .115
FAP4WAGSCZ  . . . . . . . . . . . . . . . . .115
FAP4WBUDSCZ  . . . . . . . . . . . . . . . .115
FAP4WEIDSC  . . . . . . . . . . . . . . . . . .115
FAP6WAGSCZ  . . . . . . . . . . . . . . . . .115
FAP6WBUDLCZ  . . . . . . . . . . . . . . . .115
FAP6WBUDSC  . . . . . . . . . . . . . . . 15,17
FAP6WBUDSCZ  . . . . . . . . . . . . . . . .115
FAP6WBUSCZ  . . . . . . . . . . . . . . . . .115
FAP6WEIDLC  . . . . . . . . . . . . . . . . . .115
FAP6WEIDSC  . . . . . . . . . . . . . . . . . .115
FAP6WEIDSC  . . . . . . . . . . . . . . . . 15,17
FAP6WEISC  . . . . . . . . . . . . . . . . . . .115
FAP6WFC  . . . . . . . . . . . . . . . . . .15,116
FAP6WFCZ  . . . . . . . . . . . . . . . . . . . .116
FAP6WST  . . . . . . . . . . . . . . . . . . . . .115
FAP6WSTA  . . . . . . . . . . . . . . . . . . . .115
FAP6WSTZ  . . . . . . . . . . . . . . . . . . . .115
FAP8WST  . . . . . . . . . . . . . . . . . . . . .115
FAP8WSTZ  . . . . . . . . . . . . . . . . . . . .115
FAPB  . . . . . . . . . . . . . . . . . . . . . . . . .116
FASJLCZBU-L . . . . . . . . . . . . . . . . . . .14
FASSCAQ-L  . . . . . . . . . . . . . . . . . . . .95
FASSCAQ-L  . . . . . . . . . . . . . . . . . . . .95

Panduit-Pannet-html.html
background image

393

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

FASSCEI-L  . . . . . . . . . . . . . . . . . . . . .95
FASSCZAG-L  . . . . . . . . . . . . . . . .95,115
FASSCZAQ-L  . . . . . . . . . . . . . . . . . . .95
FASSCZBU-L  . . . . . . . . . . . . . . . . 14,95
FASSLCZAQ-L  . . . . . . . . . . . . . . . . . .98
FASSLCZBU-L  . . . . . . . . . . . . . 14,97,98
FBA10IW-X  . . . . . . . . . . . . . . . . . . . .317
FBA5IW-X  . . . . . . . . . . . . . . . . . . . . .317
FBB2-X  . . . . . . . . . . . . . . . . . . . . . . .239
FBB4-X  . . . . . . . . . . . . . . . . . . . . . . .239
FBC2X2YL  . . . . . . . . . . . . . . . . . . . .231
FBFSP  . . . . . . . . . . . . .106,107,108,109
FBFSPM . . . . . . . . . . . . . . . . . . .108,109
FC12SCMFCM  . . . . . . . . . . . . . . . . .116
FC12SCMFCS  . . . . . . . . . . . . . . . . .116
FC12SCMP5  . . . . . . . . . . . . . . . . . . .116
FC12SCSP5  . . . . . . . . . . . . . . . . . . .116
FC6SCMFCM  . . . . . . . . . . . . . . . . . .116
FC6SCMFCS  . . . . . . . . . . . . . . . . . .116
FC6SCMP5  . . . . . . . . . . . . . . . . . . . .116
FC6SCSP5  . . . . . . . . . . . . . . . . . . . .116
FC6STMFCM  . . . . . . . . . . . . . . . . . .116
FC6STMFCS  . . . . . . . . . . . . . . . . . . .116
FC6STMP5  . . . . . . . . . . . . . . . . . . . .116
FC6STSP5  . . . . . . . . . . . . . . . . . . . .116
FC8FJMFCM  . . . . . . . . . . . . . . . . . . .116
FC8FJMFCS  . . . . . . . . . . . . . . . . . . .116
FC8FJMP5  . . . . . . . . . . . . . . . . . . . .116
FC8FJSP5  . . . . . . . . . . . . . . . . . . . . .116
FCF2X2YL  . . . . . . . . . . . . . . . . . . . .237
FCF4X4YL  . . . . . . . . . . . . . . . . . . . .237
FCFP . . . . . . . . . . . . . . . . . . . . . . . . . .34
FCFPAW  . . . . . . . . . . . . . . . . . . . . . . .34
FCFPIW  . . . . . . . . . . . . . . . . . . . . . . .34
FCFPPW  . . . . . . . . . . . . . . . . . . . . . . .34
FCRP5  . . . . . . . . . . . . . . . .106,107,109
FCVR  . . . . . . . . . . . . . . . . . . . . . . . .109
FEC2X2YL  . . . . . . . . . . . . . . . . . . . .237
FEC4X4YL  . . . . . . . . . . . . . . . . . . . .237
FEIAB58  . . . . . . . . . . . . . . .205,215,241
FEL  . . . . . . . . . . . . . . . . . . . . . . . . . .118
FELS  . . . . . . . . . . . . . . . . . . . . . . . . .118
FELU  . . . . . . . . . . . . . . . . . . . . . . . . .118
FFWC2X2YL  . . . . . . . . . . . . . . . . . . .237
FFWC4X4YL  . . . . . . . . . . . . . . . . . . .237
FGLS  . . . . . . . . . . . . . .106,107,108,109
FHDEC2X2YL  . . . . . . . . . . . . . . . . . .231
FHSCT  . . . . . . . . . . . . . . . . . . . .107,108
FHSCT-W  . . . . . . . . . . . . . . . . . . . . .107
FIDT2X2YL  . . . . . .202,211,224,231,237
FIDT4X4BL  . . . . . . . . . . . . .210,223,237
FITF2X2  . . . . . . . . . . . . . . . . . . . . . .239
FITF4X4A  . . . . . . . . . . . . . . . . . . . . .239
FITF4X4B  . . . . . . . . . . . . . . . . . . . . .239
FITF6X4  . . . . . . . . . . . . . . . . . . . . . .212
FIV452X2YL  . . . . . . . . . . . . . . . . . . .238
FIV454X4YL  . . . . . . . . . . . . . . . . . . .238
FIVRA2X2YL . . . . . . . . . . . . . . . . . . .238
FIVRA4X4YL . . . . . . . . . . . . . . . . . . .238
FJEPGM2.0CEI  . . . . . . . . . . . . .102,103
FJEPGM5CAW  . . . . . . . . . . . . . . . . .102
FJEPGM5CEI  . . . . . . . . . . . . . . . . . . .16
FJEPGM5CQWH  . . . . . . . . . . . . . . .102
FJEPGM5CWBL  . . . . . . . . . . . . . . . .102
FJEPGM5CXRD  . . . . . . . . . . . . . . . .102
FJEPGM5CYOR  . . . . . . . . . . . . . . . .102
FJEPGM5CZYL  . . . . . . . . . . . . . . . .102
FJEPGS2.0CBU . . . . . . . . . . . . .102,103

FJEPGS9CBU  . . . . . . . . . . . . . . .14,102
FJGCCEI  . . . . . . . . . . . . . . . . . . .16,102
FJJ9FRL-X  . . . . . . . . . . . . . . . . .101,103
FJJFRL-X  . . . . . . . . . . . . . . . . . .101,103
FJJGM2.0CEI  . . . . . . . . . . . . . . . . . .103
FJJGM5CEI  . . . . . . . . . . . . . . . . .16,100
FJJGM5CWBL  . . . . . . . . . . . . . . . . .100
FJJGM5CXRD  . . . . . . . . . . . . . . . . .100
FJJGM5CYOR  . . . . . . . . . . . . . . . . .100
FJJGM5CZYL  . . . . . . . . . . . . . . . . . .100
FJJGS2.0CBU . . . . . . . . . . . . . . . . . .103
FJJGS9CBU . . . . . . . . . . . . . . . . .14,100
FJJSMM50CAW  . . . . . . . . . . . . . . . .101
FJJSMM50CEI  . . . . . . . . . . . . . . . . . .16
FJJSMM50CWBL  . . . . . . . . . . . . . . . .99
FJJSMM50CXRD  . . . . . . . . . . . . . . . .99
FJJSMM50CYOR  . . . . . . . . . . . . . . . .99
FJJSMM50CZYL . . . . . . . . . . . . . . . . .99
FJJSMM50FRL-X  . . . . . . . . . . . . . . . .99
FJJSMM5CAW  . . . . . . . . . . . . . . . . .101
FJJSMM5CEI  . . . . . . . . . . . . . . . . . . .16
FJJSMM5CWBL  . . . . . . . . . . . . . . . . .99
FJJSMM5CXRD  . . . . . . . . . . . . . . . . .99
FJJSMM5CYOR  . . . . . . . . . . . . . . . . .99
FJJSMM5CZYL . . . . . . . . . . . . . . . . . .99
FJJSMMFRL-X  . . . . . . . . . . . . . . . . . .99
FJKITG  . . . . . . . . . . . . . . . . . .14,17,109
FJKITG-RFB  . . . . . . . . . . . . . . . . . . .109
FJMVKIT  . . . . . . . . . . . . . . . . .14,17,107
FJPKGU  . . . . . . . . . . . . . . . . . . . . . .107
FJPMR  . . . . . . . . . . . . . . . . . . . . . . .108
FJPXY  . . . . . . . . . . . . . . . . . . . .108,109
FJQCVR . . . . . . . . . . . . . . . . . . .106,107
FJQCVRB  . . . . . . . . . . . . . . . . .106,107
FK2BJ  . . . . . . . . . . . . . . . . . . . . . . . .128
FK4BJ  . . . . . . . . . . . . . . . . . . . . . . . .128
FKC  . . . . . . . . . . . . . . . . . . . . . .107,109
FKS  . . . . . . . . . . . . . . . . . . . . . .106,108
FL12X12GR-A . . . . . . . . . . . . . . . . . .242
FL25X25GR-A . . . . . . . . . . . . . . . . . .242
FL50X50GR-A . . . . . . . . . . . . . . . . . .242
FLB  . . . . . . . . . . . . . . . . . . . . . . . . . .240
FLB12X15  . . . . . . . . . . . . . .205,214,240
FLB12X20  . . . . . . . . . . . . . .205,214,240
FLB58X15  . . . . . . . . . . . . . .205,214,240
FLB58X20  . . . . . . . . . . . . . .205,214,240
FLB-6P-6S-PA . . . . . . . . . . . . . . . . . .128
FLB-6P-9S-UA  . . . . . . . . . . . . . . . . .128
FLCASCP  . . . . . . . . . . . . . . . . . . . . .108
FLCCLIPBL-L  . . . . . . . . . . . . . . . . . . .93
FLCCLIP-L  . . . . . . . . . . . . . . . . . .97,103
FLCDM900EI  . . . . . . . . . . . . . . . . . . .97
FLCDMC6BL . . . . . . . . . . . . . . . . . . . .93
FLCDMCXAQ  . . . . . . . . . . . . . . . . . . .93
FLCDMEI  . . . . . . . . . . . . . . . . . . . .16,97
FLCDS900BU  . . . . . . . . . . . . . . . . . . .97
FLCDSBU  . . . . . . . . . . . . . . . . . . . 14,97
FLCDSCBU . . . . . . . . . . . . . . . . . . . . .93
FLCFPLF-X  . . . . . . . . . . . . . . . . . . . .108
FLCPAD  . . . . . . . . . . . . . . . . . . . . . .108
FLCPK . . . . . . . . . . . . . . . . . . . . . . . .108
FLCSMC5BL  . . . . . . . . . . . . . . . . . . . .93
FLCSMC6BL  . . . . . . . . . . . . . . . . . . . .93
FLCSMCXAQ  . . . . . . . . . . . . . . . . . . .93
FLCSMEI  . . . . . . . . . . . . . . . . . . . .16,97
FLCSSBU . . . . . . . . . . . . . . . . . . . .14,96
FLCSSCBU  . . . . . . . . . . . . . . . . . . . . .93
FLPKIT  . . . . . . . . . . . . . . . . . . . . . . .108

FLPKIT-RFB  . . . . . . . . . . . . . . . . . . .108
FLPKIT-W . . . . . . . . . . . . . . . . . . .17,108
FLPT  . . . . . . . . . . . . . . . . . . . . .107,108
FLRB  . . . . . . . . . . . . . . . . . . . . . . . . .240
FMCBT2BL-X  . . . . . . . . . . . . . . . . 93,94
FMCBT3BL-X  . . . . . . . . . . . . . . . . 93,94
FMD1 . . . . . . . . . . . . . . . . . . . . . . . . .112
FMD2 . . . . . . . . . . . . . . . . . . . . . . . . .112
FMD's  . . . . . . . . . . . . . . . . . . . . . . 15,17
FMP6  . . . . . . . . . . . . . . . . . . . . . . . . .115
FMD24FJMP  . . . . . . . . . . . . . . . . . . .113
FMD24STMP . . . . . . . . . . . . . . . . . . .113
FMD48FJMP  . . . . . . . . . . . . . . . . . . .113
FMD48SCMP  . . . . . . . . . . . . . . . . . .113
FMD48STMP . . . . . . . . . . . . . . . . . . .113
FMP6WMTRJ  . . . . . . . . . . . . . . . . . .116
FMP6WMTRJBL  . . . . . . . . . . . . . . . .116
FMRB  . . . . . . . . . . . . . . . . . . . . . . . .241
FMT1  . . . . . . . . . . . . . . . . . . . . . . . . .111
FMT2  . . . . . . . . . . . . . . . . . . . . . . . . .111
FMT24FJMP  . . . . . . . . . . . . . . . . . . .113
FMT24SCMP . . . . . . . . . . . . . . . . . . .113
FMT24STMP  . . . . . . . . . . . . . . . . . . .113
FMT48FJMP  . . . . . . . . . . . . . . . . . . .113
FMT48SCMP . . . . . . . . . . . . . . . . . . .113
FMT48STMP  . . . . . . . . . . . . . . . . . . .113
FMT's  . . . . . . . . . . . . . . . . . . . . . . 15,17
FOV452X2YL  . . . . . . . . . . . . . . . . . .238
FOV454X4YL  . . . . . . . . . . . . . . . . . .238
FOVRA2X2YL  . . . . . . . . . . . . . . . . . .238
FOVRA4X4YL  . . . . . . . . . . . . . . . . . .238
FPAD  . . . . . . . . . . . . . . . . . . . . . . . . .109
FPCL-Q  . . . . . . . . . . . . . . . . . . . . . . .109
FPF1-V . . . . . . . . . . . . . . . . . . . .108,109
FPP1-L  . . . . . . . . . . . . . . . . . . . . . . .109
FPP5-L  . . . . . . . . . . . . . . . . . . . .108,109
FPPKIT  . . . . . . . . . . . . . . . . . . . . . . .106
FPPKIT-CV  . . . . . . . . . . . . . . . . . . . .106
FPPRKIT  . . . . . . . . . . . . . . . . . . . . . .106
FPPTTKIT  . . . . . . . . . . . . . . . . . . . . .106
FPSL  . . . . . . . . . . . . . . . . . . . . . . . . .109
FPWIRE  . . . . . . . . . . . . . . . . . . . . . .108
FR1.5IDEYL  . . . . . . . . . . . .201,210,222
FR12ACB12  . . . . . . . . . . . . . . . . . . .204
FR12ACB12M  . . . . . . . . . . . . . . . . . .204
FR12ACB58  . . . . . . . . . . . . . . . . . . .204
FR12ACB58M  . . . . . . . . . . . . . . . . . .204
FR12ALB . . . . . . . . . . . . . . . . . . . . . .204
FR12BS-L  . . . . . . . . . . . . . . . . .204,205
FR12CS12  . . . . . . . . . . . . . . . . . . . .204
FR12CS12M  . . . . . . . . . . . . . . . . . . .204
FR12CS58  . . . . . . . . . . . . . . . . . . . .204
FR12CS58M  . . . . . . . . . . . . . . . . . . .204
FR12TB12 . . . . . . . . . . . . . . . . . . . . .204
FR12TB12M  . . . . . . . . . . . . . . . . . . .204
FR12TB58 . . . . . . . . . . . . . . . . . . . . .204
FR12TB58M  . . . . . . . . . . . . . . . . . . .204
FR12TRBE58  . . . . . . . . . . . . . . . . . .204
FR12TRBE58M . . . . . . . . . . . . . . . . .204
FR12TRBN58  . . . . . . . . . . . . . . . . . .204
FR12TRBN58M . . . . . . . . . . . . . . . . .204
FR12USB  . . . . . . . . . . . . . . . . . . . . .204
FR12X4YL6 . . . . . . . . . . . . . . . . . . . .198
FR38BIT  . . . . . . . . . . . . . . . . . . . . . .227
FR38DR  . . . . . . . . . . . . . . . . . . . . . .227
FR4X4YL6 . . . . . . . . . . . . . . . . . . . . .220
FR6ACAB  . . . . . . . . . . . . . . . . . . . . .215
FR6ACB12  . . . . . . . . . . . . . . . . . . . .213

Panduit-Pannet-html.html
background image

394

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

394

FR6ACB12M  . . . . . . . . . . . . . . . . . . .213
FR6ACB58  . . . . . . . . . . . . . . . . . . . .213
FR6ACB58M  . . . . . . . . . . . . . . . . . . .213
FR6ALB . . . . . . . . . . . . . . . . . . . . . . .213
FR6CS12  . . . . . . . . . . . . . . . . . . . . .213
FR6CS12M  . . . . . . . . . . . . . . . . . . . .213
FR6CS58  . . . . . . . . . . . . . . . . . . . . .213
FR6CS58M  . . . . . . . . . . . . . . . . . . . .213
FR6LB  . . . . . . . . . . . . . . . . . . . . . . . .214
FR6LRB  . . . . . . . . . . . . . . . . . . . . . .214
FR6RMBEIA  . . . . . . . . . . . . . . . . . . .215
FR6TB12 . . . . . . . . . . . . . . . . . . . . . .214
FR6TB12M  . . . . . . . . . . . . . . . . . . . .214
FR6TB38 . . . . . . . . . . . . . . . . . . . . . .214
FR6TB38M  . . . . . . . . . . . . . . . . . . . .214
FR6TRBE12  . . . . . . . . . . . . . . . . . . .213
FR6TRBE12M . . . . . . . . . . . . . . . . . .213
FR6TRBE58  . . . . . . . . . . . . . . . . . . .213
FR6TRBE58M . . . . . . . . . . . . . . . . . .213
FR6TRBN12  . . . . . . . . . . . . . . . . . . .213
FR6TRBN12M . . . . . . . . . . . . . . . . . .213
FR6TRBN58  . . . . . . . . . . . . . . . . . . .213
FR6TRBN58M . . . . . . . . . . . . . . . . . .213
FR6USB  . . . . . . . . . . . . . . . . . . . . . .213
FR6X4YL6 . . . . . . . . . . . . . . . . . . . . .208
FR716BIT  . . . . . . . . . . . . . . . . . . . . .227
FR716DR  . . . . . . . . . . . . . . . . . . . . .227
FRA2X2YL  . . . . . . . . . . . . . . . . . . . .237
FRA4X4YL  . . . . . . . . . . . . . . . . . . . .237
FRADC12X4BL  . . . . . . . . . . . . . . . . .216
FRADC4X4BL  . . . . . . . . . . . . . . . . . .216
FRADC6X4YL  . . . . . . . . . . . . . . . . . .216
FRBB6-X  . . . . . . . . . . . . . . . . . . . . . .215
FRBC12X4YL  . . . . . . . . . . . . . . . . . .199
FRBC4X4YL  . . . . . . . . . . . . . . . . . . .221
FRBC6X4YL  . . . . . . . . . . . . . . . . . . .209
FRCR12BL-X  . . . . . . . . . . . . . . . . . .198
FRCR4BL-X  . . . . . . . . . . . . . . . . . . .220
FRCR6BL-X  . . . . . . . . . . . . . . . . . . .208
FRCUT  . . . . . . . . . . . . . . . . . . . . . . .227
FRDDS6X4YL  . . . . . . . . . . . . . . . . . .211
FRDDSHC6YL  . . . . . . . . . . . . . . . . .211
FREC12X4YL  . . . . . . . . . . . . . . . . . .201
FREC4X4YL  . . . . . . . . . . . . . . . . . . .222
FREC6X4YL  . . . . . . . . . . . . . . . . . . .210
FRF42YL . . . . . . . . . . . . . . . . . . . . . .238
FRF4544BL . . . . . . . . . . . . . . . . . . . .238
FRFWC12X4W6YL  . . . . . . . . . . . . . .200
FRFWC12X4YL  . . . . . . . . . . . . . . . .200
FRFWC4X4YL  . . . . . . . . . . . . . . . . .222
FRFWC6X4YL  . . . . . . . . . . . . . . . . .210
FRFWCSC12W6YL  . . . . . . . . . . . . .200
FRFWCSC12YL  . . . . . . . . . . . . . . . .200
FRFWCSC4YL  . . . . . . . . . . . . . . . . .222
FRFWCSC6YL  . . . . . . . . . . . . . . . . .210
FRH4512X4YL  . . . . . . . . . . . . . . . . .199
FRH454X4YL  . . . . . . . . . . . . . . . . . .221
FRH456X4YL  . . . . . . . . . . . . . . . . . .209
FRH45SC12YL  . . . . . . . . . . . . . . . . .199
FRH45SC4YL  . . . . . . . . . . . . . . . . . .221
FRH45SC6YL  . . . . . . . . . . . . . . . . . .209
FRHC12YL6  . . . . . . . . . . . . . . . . . . .198
FRHC4YL6  . . . . . . . . . . . . . . . . . . . .220
FRHC6YL6  . . . . . . . . . . . . . . . . . . . .208
FRIDT4X4YL . . . . . . . . . . . . . . . . . . .223
FRIDT6X4YL . . . . . . . . . . . . . . . . . . .201
FRIV4512X4YL  . . . . . . . . . . . . . . . . .202
FRIV454X4YL  . . . . . . . . . . . . . . . . . .224

FRIV456X4YL  . . . . . . . . . . . . . . . . . .211
FRLPR42BL  . . . . . . . . . . . . . . . .210,223
FRLT  . . . . . . . . . . . . . . . . . . . . . . . 15,17
FRME1  . . . . . . . . . . . . . . . . . . . . . . .110
FRME144SBL  . . . . . . . . . . . . . . . . . .110
FRME2  . . . . . . . . . . . . . . . . . . . . . . .110
FRME3  . . . . . . . . . . . . . . . . . . . . . . .110
FRME4  . . . . . . . . . . . . . . . . . . . . . . .110
FRME48AIBL  . . . . . . . . . . . . . . . . . .110
FRME48AINSBL  . . . . . . . . . . . . . . . .110
FRME72SBL  . . . . . . . . . . . . . . . . . . .110
FRME's  . . . . . . . . . . . . . . . . . . . . . 15,17
FROV4512X4YL  . . . . . . . . . . . . . . . .202
FROV454X4YL  . . . . . . . . . . . . . . . . .224
FROV456X4YL  . . . . . . . . . . . . . . . . .212
FROV45SC12YL . . . . . . . . . . . . . . . .202
FROV45SC4YL . . . . . . . . . . . . . . . . .225
FROV45SC6YL . . . . . . . . . . . . . . . . .212
FROVRA12X4YL  . . . . . . . . . . . . . . .202
FROVRA4X4YL  . . . . . . . . . . . . . . . .225
FROVRA6X4YL  . . . . . . . . . . . . . . . .212
FROVRASC12YL  . . . . . . . . . . . . . . .202
FROVRASC4YL  . . . . . . . . . . . . . . . .225
FROVRASC6YL  . . . . . . . . . . . . . . . .212
FRRA12X4YL  . . . . . . . . . . . . . . . . . .199
FRRA4X4YL  . . . . . . . . . . . . . . . . . . .221
FRRA6X4YL  . . . . . . . . . . . . . . . . . . . .20
FRRASC12YL  . . . . . . . . . . . . . . . . . .199
FRRASC4YL  . . . . . . . . . . . . . . . . . . .221
FRRASC6YL  . . . . . . . . . . . . . . . . . . .209
FRRF126LSCYL  . . . . . . . . . . . . . . . .203
FRRF126LYLYL  . . . . . . . . . . . . . . . .203
FRRF126RSCYL . . . . . . . . . . . . . . . .203
FRRF126RYL  . . . . . . . . . . . . . . . . . .203
FRRF126SCYL  . . . . . . . . . . . . . . . . .203
FRRF126YL  . . . . . . . . . . . . . . . . . . .203
FRRF4FD2YL  . . . . . . . . . . . . . . . . . .226
FRRF4FD4YL  . . . . . . . . . . . . . . . . . .226
FRRF64YL  . . . . . . . . . . . . . . . . . . . .212
FRRF6FR4SCYL  . . . . . . . . . . . .212,225
FRRF6FR4YL  . . . . . . . . . . . . . .212,225
FRRMBNF58 . . . . . . . . . . . . . . . . . . .215
FR's . . . . . . . . . . . . . . . . . . . . . . . . 15,17
FRSHC4YL6  . . . . . . . . . . . . . . . . . . .220
FRSHC6YL6  . . . . . . . . . . . . . . . . . . .208
FRSLNKT12  . . . . . . . . . . . .205,215,241
FRSLNKT12M . . . . . . . . . . .205,215,241
FRSLNKT58  . . . . . . . . . . . .205,215,241
FRSLNKT58M  . . . . . . . . . . . . . .205,215
FRSP12CYL  . . . . . . . . . . . . . . . . . . .201
FRSP412CYL  . . . . . . . . . . . . . . . . . .202
FRSP44CYL  . . . . . . . . . . . . . . . . . . .224
FRSP46CYL  . . . . . . . . . . . . . . . . . . .211
FRSP4CYL  . . . . . . . . . . . . . . . . . . . .223
FRSP4YL  . . . . . . . . . . . . . .201,211,224
FRSP6CYL  . . . . . . . . . . . . . . . . . . . .211
FRSPYL  . . . . . . . . . . . . . . .201,211,223
FRSTRCLIP  . . . . . . . . . . . . . . . .205,215
FRT12X4W6YL  . . . . . . . . . . . . . . . . .200
FRT12X4YL  . . . . . . . . . . . . . . . . . . .199
FRT4X4YL  . . . . . . . . . . . . . . . . . . . .221
FRT6X4YL  . . . . . . . . . . . . . . . . . . . .209
FRTR12X4YL  . . . . . . . . . . . . . . . . . .200
FRTR4X4YL  . . . . . . . . . . . . . . . . . . .222
FRTR6X4YL  . . . . . . . . . . . . . . . .201,210
FRTSC12W6YL  . . . . . . . . . . . . . . . .200
FRTSC12YL  . . . . . . . . . . . . . . . . . . .200
FRTSC4YL  . . . . . . . . . . . . . . . . . . . .222

FRTSC6YL  . . . . . . . . . . . . . . . . . . . .133
FRTYT68 . . . . . . . . . . . . . . . . . . . . . .216
FRUIB-X  . . . . . . . . . . . . . . . . . . . . . .227
FRUPS4X4YL  . . . . . . . . . . . . . . . . . .225
FRUPS6X4YL  . . . . . . . . . . . . . . . . . .212
FRVT12X4YL  . . . . . . . . . . . . . . . . . .201
FRVT4X4YL  . . . . . . . . . . . . . . . . . . .222
FRVT6X4YL  . . . . . . . . . . . . . . . . . . .210
FRWBS68  . . . . . . . . . . . . . . . . . . . . .216
FRY126SCYL  . . . . . . . . . . . . . . . . . .203
FRY126YL . . . . . . . . . . . . . . . . . . . . .203
FS.5X.5LG6NM . . . . . . . . . . . . . . . . .246
FS.5X1LG6NM  . . . . . . . . . . . . . . . . .246
FS.75X.75LG6NM . . . . . . . . . . . . . . .246
FS1.5X1.5LG6NM . . . . . . . . . . . . . . .246
FS1.5X1LG6NM  . . . . . . . . . . . . . . . .246
FS1.5X2LG6NM  . . . . . . . . . . . . . . . .246
FS1.5X3LG6NM  . . . . . . . . . . . . . . . .246
FS1X1.5LG6NM  . . . . . . . . . . . . . . . .246
FS1X1LG6NM . . . . . . . . . . . . . . . . . .246
FS1X2LG6NM . . . . . . . . . . . . . . . . . .246
FS1X3LG6NM . . . . . . . . . . . . . . . . . .246
FS2X1.5LG6NM  . . . . . . . . . . . . . . . .246
FS2X1LG6NM . . . . . . . . . . . . . . . . . .246
FS2X2LG6NM . . . . . . . . . . . . . . . . . .246
FS2X3LG6NM . . . . . . . . . . . . . . . . . .246
FS3X1LG6NM . . . . . . . . . . . . . . . . . .246
FS3X2LG6NM . . . . . . . . . . . . . . . . . .246
FS3X3LG6NM . . . . . . . . . . . . . . . . . .246
FS3X4LG6NM . . . . . . . . . . . . . . . . . .246
FS3X5LG6NM . . . . . . . . . . . . . . . . . .246
FS4X2LG6NM . . . . . . . . . . . . . . . . . .246
FS4X3LG6NM . . . . . . . . . . . . . . . . . .246
FS4X4LG6NM . . . . . . . . . . . . . . . . . .246
FS4X5LG6NM . . . . . . . . . . . . . . . . . .246
FS6X4LG6NM . . . . . . . . . . . . . . . . . .246
FSCBT2BU-X  . . . . . . . . . . . . . . . . 93,94
FSCBT3BU-X  . . . . . . . . . . . . . . . . 93,94
FSCCLIP-L . . . . . . . . . . . . . . . . . .94,103
FSCDM  . . . . . . . . . . . . . . . . . . . . . . . .95
FSCDMC5BL  . . . . . . . . . . . . . . . . . . .94
FSCDMC6BL  . . . . . . . . . . . . . . . . . . .94
FSCDMCXAQ  . . . . . . . . . . . . . . . . . . .94
FSCDVR  . . . . . . . . . . .106,107,108,109
FSCM2.0BL  . . . . . . . . . . . . . . . . .95,103
FSCM2.0RD . . . . . . . . . . . . . . . . .95,103
FSCMBL  . . . . . . . . . . . . . . . . . . . . . . .95
FSCMC5BL  . . . . . . . . . . . . . . . . . . . . .94
FSCMC6BL  . . . . . . . . . . . . . . . . . . . . .94
FSCMCXAQ  . . . . . . . . . . . . . . . . . . . .94
FSCMM  . . . . . . . . . . . . . . . . . . . . . . . .16
FSCMM2.0BL  . . . . . . . . . . . . . . . . . .103
FSCMM2.0RD . . . . . . . . . . . . . . . . . .103
FSCMM50  . . . . . . . . . . . . . . . . . . . . . .16
FSCMM50BL . . . . . . . . . . . . . . . . . . . .16
FSCMM50RD  . . . . . . . . . . . . . . . . . . .16
FSCMM502.0BL  . . . . . . . . . . . . . . . .103
FSCMM502.0RD . . . . . . . . . . . . . . . .103
FSCMMBL . . . . . . . . . . . . . . . . . . . . . .95
FSCMMBL . . . . . . . . . . . . . . . . . . . . . .95
FSCMMRD  . . . . . . . . . . . . . . . . . . . . .95
FSCMRD . . . . . . . . . . . . . . . . . . . . . . .95
FSCOPE  . . . . . . . . . . . . . . . . . . . . . .108
FSCP . . . . . . . . . . . . . . . . . . . . . . . . .109
FSCRBLD  . . . . . . . . . . . . . . . . . . . . .108
FSCRIBE . . . . . . . . . . . . . . . . . . . . . .108
FSCS2.0BU  . . . . . . . . . . . . . . . . .95,103
FSCSBU . . . . . . . . . . . . . . . . . . . . .14,95

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

Panduit-Pannet-html.html
background image

395

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

FSCSCBU  . . . . . . . . . . . . . . . . . . . . . .94
FST  . . . . . . . . . . . . . . .106,107,108,109
FST24  . . . . . . . . . . . . . . . . . . . . . . . .116
FST24H3  . . . . . . . . . . . . . . . . . . . . . .116
FST24S  . . . . . . . . . . . . . . . . . . .117,158
FST6  . . . . . . . . . . . . . . . . . . . . . . . . .116
FST6H4  . . . . . . . . . . . . . . . . . . . . . . .116
FSTHDH9  . . . . . . . . . . . . . . . . . . . . .158
FSTHDH9BL  . . . . . . . . . . . . . . . . . . .158
FSTHE . . . . . . . . . . . . . . . . . . . . . . . .116
FSTHED  . . . . . . . . . . . . . . . . . . .117,158
FSTHS . . . . . . . . . . . . . . . . . . . . . . . .116
FSTK  . . . . . . . . . . . . . . . . . . . . . . . . .116
FSTLSKIT  . . . . . . . . . . . . . . . . . . . . .106
FSTMABL  . . . . . . . . . . . . . . . . . . . . . .92
FSTMARD . . . . . . . . . . . . . . . . . . . . . .92
FSTMM  . . . . . . . . . . . . . . . . . . . . . . . .16
FSTMM50  . . . . . . . . . . . . . . . . . . . . . .16
FSTMM50BL  . . . . . . . . . . . . . . . . . . . .92
FSTMM50RD  . . . . . . . . . . . . . . . . . . .92
FSTMMBL  . . . . . . . . . . . . . . . . . . . . . .92
FSTMMRD  . . . . . . . . . . . . . . . . . . . . .92
FSTSABU  . . . . . . . . . . . . . . . . . . . 14,92
FSWB-C  . . . . . . . . . . . . . . .106,108,109
FSYR-X  . . . . . . . . . . . . . . . . . . .108,109
FT124MC . . . . . . . . . . . . . . . . . . . . . .111
FT1W12DSC  . . . . . . . . . . . . . . . . . . .111
FT1W12ST  . . . . . . . . . . . . . . . . . . . .111
FT1W24ST  . . . . . . . . . . . . . . . . . . . .111
FT1W's  . . . . . . . . . . . . . . . . . . . . . 15,17
FT2X2YL  . . . . . . . . . . . . . . . . . . . . . .237
FT4X4YL  . . . . . . . . . . . . . . . . . . . . . .237
FTDNS4X4YL  . . . . . . . . . . . . . . . . . .216
FTR2X2YL  . . . . . . . . . .202,211,224,238
FTR4X4YL  . . . . . . . . . . . . .210,223,237
FTRB12  . . . . . . . . . . . . . . . . . . .215,240
FTRB58  . . . . . . . . . . . . . . . . . . .215,240
FTRBE12  . . . . . . . . . . . . . . . . . . . . .240
FTRBE12M  . . . . . . . . . . . . . . . . . . . .240
FTRBE58  . . . . . . . . . . . . . . . . . . . . .240
FTRBN12  . . . . . . . . . . . . . . . . . . . . .240
FTRBN12M  . . . . . . . . . . . . . . . . . . . .240
FTRBN58  . . . . . . . . . . . . . . . . . . . . .240
FTRM-SC1  . . . . . . . . . . . . . . . . . . . .129
FTWZR  . . . . . . . . . . . . . . . .106,108,109
FUSB . . . . . . . . . . . . . . . . . . . . . . . . .240
FVFL  . . . . . . . . . . . . . . . . . . . . . .17,107
FVFLKIT . . . . . . . . . . . . . . . . . . . .17,107
FVFLPC  . . . . . . . . . . . . . . . .17,106,107
FVFLPC-1.25SM . . . . . . . . . . . . . . . .106
FVFLPC-2.5SM . . . . . . . . . . . . . . . . .106
FVT4X4YL . . . . . . . . . . . . . . . . . . . . .237
FVTHD2X2YL  . . . . . . . . . . . . . .231,237
FWBTL  . . . . . . . . . . . . . . . .106,108,109
FWME12STMP  . . . . . . . . . . . . . . . . .114
FWME2  . . . . . . . . . . . . . . . . . . . . . . .114
FWME4  . . . . . . . . . . . . . . . . . . . . . . .114
FWME8  . . . . . . . . . . . . . . . . . . . . . . .114
FWME's . . . . . . . . . . . . . . . . . . . . . 15,17
FWP-C  . . . . . . . . . . . . .106,107,108,109
FWR-C  . . . . . . . . . . . . . . . . . . . . . . .245
FWRKMAT  . . . . . . . . . . . . . . . . .106,108
FXB3-NM1  . . . . . . . . . . . . . . . . . . . .123
FXB6J-NM1 . . . . . . . . . . . . . . . . . . . .124
FXCBT2AQ-X  . . . . . . . . . . . . . . . . 93,94
FXD3-3M . . . . . . . . . . . . . . . . . . . . . .123
FXD3-3M1 . . . . . . . . . . . . . . . . . . . . .123
FXD6J-NM  . . . . . . . . . . . . . . . . . . . .123

FXD6J-NM1  . . . . . . . . . . . . . . . . . . .123
FXD6P-3M1  . . . . . . . . . . . . . . . . . . .124
FXD6P-6PM  . . . . . . . . . . . . . . . . . . .123
FXD6P-6PM1  . . . . . . . . . . . . . . . . . .123
FXD6PQ-3M1  . . . . . . . . . . . . . . . . . .124
FXD6PW-3M1  . . . . . . . . . . . . . . . . . .124
FXD6PX-3M1  . . . . . . . . . . . . . . . . . .124
FXD6PY-3M1  . . . . . . . . . . . . . . . . . .124
FXD6PZ-3M1  . . . . . . . . . . . . . . . . . .124
FXE10-10M  . . . . . . . . . . . . . . . . . . . .123
FXE10-10M1  . . . . . . . . . . . . . . . . . . .123
FXE3-10M1  . . . . . . . . . . . . . . . .123,124
FZBA1.5X4  . . . . . . . . . . . . . . . . . . . .240

G

G.5X.5LG6  . . . . . . . . . . . . . . . . . . . .243
G.5X1LG6  . . . . . . . . . . . . . . . . . . . . .243
G.5X4LG6  . . . . . . . . . . . . . . . . . . . . .243
G.75X.75LG6  . . . . . . . . . . . . . . . . . .243
G.75X1.5LG6  . . . . . . . . . . . . . . . . . .243
G.75X1LG6  . . . . . . . . . . . . . . . . . . . .243
G.75X2LG6  . . . . . . . . . . . . . . . . . . . .243
G1.5X1.5LG6  . . . . . . . . . . . . . . . . . .243
G1.5X1LG6  . . . . . . . . . . . . . . . . . . . .243
G1.5X2LG6  . . . . . . . . . . . . . . . . . . . .243
G1.5X3LG6  . . . . . . . . . . . . . . . . . . . .243
G1.5X4LG6  . . . . . . . . . . . . . . . . . . . .243
G1X1.5LG6  . . . . . . . . . . . . . . . . . . . .243
G1X1LG6  . . . . . . . . . . . . . . . . . . . . .243
G1X2LG6  . . . . . . . . . . . . . . . . . . . . .243
G1X3LG6  . . . . . . . . . . . . . . . . . . . . .243
G1X4LG6  . . . . . . . . . . . . . . . . . . . . .243
G2.5X3LG6  . . . . . . . . . . . . . . . . . . . .243
G2X1.5LG6  . . . . . . . . . . . . . . . . . . . .243
G2X1LG6  . . . . . . . . . . . . . . . . . . . . .243
G2X2LG6  . . . . . . . . . . . . . . . . . . . . .243
G2X3LG6  . . . . . . . . . . . . . . . . . . . . .243
G2X4LG6  . . . . . . . . . . . . . . . . . . . . .243
G2X5LG6  . . . . . . . . . . . . . . . . . . . . .243
G3X1LG6  . . . . . . . . . . . . . . . . . . . . .243
G3X2LG6  . . . . . . . . . . . . . . . . . . . . .243
G3X3LG6  . . . . . . . . . . . . . . . . . . . . .243
G3X4LG6  . . . . . . . . . . . . . . . . . . . . .243
G3X5LG6  . . . . . . . . . . . . . . . . . . . . .243
G4X1.5LG6  . . . . . . . . . . . . . . . . . . . .243
G4X2LG6  . . . . . . . . . . . . . . . . . . . . .243
G4X3LG6  . . . . . . . . . . . . . . . . . . . . .243
G4X4LG6  . . . . . . . . . . . . . . . . . . . . .243
G4X5LG6  . . . . . . . . . . . . . . . . . . . . .243
G6X4LG6  . . . . . . . . . . . . . . . . . . . . .243
GEE144F-A-C  . . . . . . . . . . . . . . . . . .347
GEE144F-A-C0  . . . . . . . . . . . . . . . . .347
GEE144FR-C  . . . . . . . . . . . . . . . . . .347
GEE36FR-C  . . . . . . . . . . . . . . . . . . .347
GEE62F-A-C  . . . . . . . . . . . . . . . . . . .347
GEE62F-A-C0  . . . . . . . . . . . . . . . . . .347
GEE62FR-C  . . . . . . . . . . . . . . . . . . .347
GEE99F-A-C  . . . . . . . . . . . . . . . . . . .347
GEE99F-A-C0  . . . . . . . . . . . . . . . . . .347
GEE99FR-C  . . . . . . . . . . . . . . . . . . .347
GES144F-A-C  . . . . . . . . . . . . . . . . . .347
GES144F-A-C0  . . . . . . . . . . . . . . . . .347
GES144FR-C  . . . . . . . . . . . . . . . . . .347
GES36FR-C  . . . . . . . . . . . . . . . . . . .347
GES62F-A-C  . . . . . . . . . . . . . . . . . . .347
GES62F-A-C0  . . . . . . . . . . . . . . . . . .347
GES62FR-C  . . . . . . . . . . . . . . . . . . .347
GES99F-A-C  . . . . . . . . . . . . . . . . . . .347

GES99F-A-C0  . . . . . . . . . . . . . . . . . .347
GES99FR-C  . . . . . . . . . . . . . . . . . . .347
GPB144-X  . . . . . . . . . . . . . . . . . . . . . .74
GPB24-X  . . . . . . . . . . . . . . . . . . . . . . .74
GPB2884R2  . . . . . . . . . . . . . . . . . 72,73
GPB2884R4WJ  . . . . . . . . . . . . . . .72,73
GPB432-X  . . . . . . . . . . . . . . . . . . . . . .74
GPB72-X  . . . . . . . . . . . . . . . . . . . . . . .74
GPBW144-X  . . . . . . . . . . . . . . . . . . . .74
GPBW24-X  . . . . . . . . . . . . . . . . . . . . .74
GPBW432-X  . . . . . . . . . . . . . . . . . . . .74
GPBW72-X  . . . . . . . . . . . . . . . . . . . . .74
GPC5E1-X  . . . . . . . . . . . . . . . . . . . . .76
GPC5E2-X  . . . . . . . . . . . . . . . . . . . . .76
GPCB4-C  . . . . . . . . . . . . . . . . . . . . . .73
GPCB4-X  . . . . . . . . . . . . . . . . . . . . . .73
GPCB5-C  . . . . . . . . . . . . . . . . . . . . . .73
GPCB5-X  . . . . . . . . . . . . . . . . . . . . . .73
GPDTM  . . . . . . . . . . . . . . . . . . . . . . . .76
GPDTMB . . . . . . . . . . . . . . . . . . . . . . .76
GPDTMH . . . . . . . . . . . . . . . . . . . . . . .76
GPKBW144   . . . . . . . . . . . . . . . . . . . .71
GPKBW24 . . . . . . . . . . . . . . . . . . . . . .72
GPKBW432 . . . . . . . . . . . . . . . . . . . . .71
GPKBW72 . . . . . . . . . . . . . . . . . . . . . .72
GPKT724  . . . . . . . . . . . . . . . . . . . . . .74
GPL-10-Q  . . . . . . . . . . . . . . . . . . . . .185
GPL-14-X  . . . . . . . . . . . . . . . . . . . . .185
GPL-15-X  . . . . . . . . . . . . . . . . . . . . .185
GPL-16-X  . . . . . . . . . . . . . . . . . . . . .185
GPL-20-X  . . . . . . . . . . . . . . . . . . . . .185
GPL-21-X  . . . . . . . . . . . . . . . . . . . . .185
GPL-22-X  . . . . . . . . . . . . . . . . . . . . .185
GPL-26-X  . . . . . . . . . . . . . . . . . . . . .185
GPL-27-X  . . . . . . . . . . . . . . . . . . . . .185
GPL-28-X  . . . . . . . . . . . . . . . . . . . . .185
GPL-32-3 . . . . . . . . . . . . . . . . . . . . . .185
GPL-33-3 . . . . . . . . . . . . . . . . . . . . . .185
GPL-34-3 . . . . . . . . . . . . . . . . . . . . . .185
GPL-39-3 . . . . . . . . . . . . . . . . . . . . . .185
GPL-40-3 . . . . . . . . . . . . . . . . . . . . . .185
GPL-44-1 . . . . . . . . . . . . . . . . . . . . . .185
GPL-45-1 . . . . . . . . . . . . . . . . . . . . . .185
GPL-46-1 . . . . . . . . . . . . . . . . . . . . . .185
GPL-4-Q  . . . . . . . . . . . . . . . . . . . . . .185
GPL-4-Q  . . . . . . . . . . . . . . . . . . . . . .185
GPL-51-1 . . . . . . . . . . . . . . . . . . . . . .185
GPL-52-1 . . . . . . . . . . . . . . . . . . . . . .185
GPL-57-1 . . . . . . . . . . . . . . . . . . . . . .185
GPL-58-1 . . . . . . . . . . . . . . . . . . . . . .185
GPL-5-Q  . . . . . . . . . . . . . . . . . . . . . .185
GPL-6-Q  . . . . . . . . . . . . . . . . . . . . . .185
GPL-8-Q  . . . . . . . . . . . . . . . . . . . . . .185
GPL-9-Q  . . . . . . . . . . . . . . . . . . . . . .185
GPPC1IG2M  . . . . . . . . . . . . . . . . . . . .83
GPPC1IG3M  . . . . . . . . . . . . . . . . . . . .83
GPPC2IG2M  . . . . . . . . . . . . . . . . . . . .83
GPPC4IG2M  . . . . . . . . . . . . . . . . . . . .82
GPPC4IG2MA . . . . . . . . . . . . . . . . . . .82
GPPC4IG2MB . . . . . . . . . . . . . . . . . . .82
GPPC4IG3MA . . . . . . . . . . . . . . . . . . .82
GPPC4IG3MB . . . . . . . . . . . . . . . . . . .82
GPST  . . . . . . . . . . . . . . . . . . . . . . . . .76
GPSTB  . . . . . . . . . . . . . . . . . . . . . . . .76
GS4MT  . . . . . . . . . . . . . . . . . . . . . . .344
GTH . . . . . . . . . . . . . . . . . . . . . . . . . .330
GTS . . . . . . . . . . . . . . . . . . . . . . . . . .330

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

Panduit-Pannet-html.html
background image

396

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

H

H2X2BL6 . . . . . . . . . . . . . . . . . . . . . .242
H2X2YL6 . . . . . . . . . . . . . . . . . . . . . .230
H4X4BL6 . . . . . . . . . . . . . . . . . . . . . .242
HC2YL6 . . . . . . . . . . . . . . . . . . . . . . .230
HDCRT

 . . . . . . . . . . . . . . . . . . . . .158

HDFE108ST

 . . . . . . . . . . . . . . . . .158

HDFE144LC  . . . . . . . . . . . .155,156,158
HDFE144SC  . . . . . . . . . . . .155,156,158
HDFE18FAP

 . . . . . . . . . .155,156,158

HDFE18FAPBL

 . . . . . . . .155,156,158

HDFE216ST

 . . . . . . . . . . . . . . . . .158

HDFE288SC     . . . . . . . . . .155,156,158
HDFE9FAP  . . . . . . . . . . . . .155,156,158
HDFE9FAPBL  . . . . . . . . . . .155,156,158
HLC3S-X     . . . . . . . . . . . . . . . . . . . .335
HLC3S-X0     . . . . . . . . . . . . . . . . . . .322
HLC5S-X     . . . . . . . . . . . . . . . . . . . .335
HLC5S-X0     . . . . . . . . . . . . . . . . . . .322
HLM-15R      . . . . . . . . . . . . . . . . . . .335
HLS1.5S-X      . . . . . . . . . . . . . . . . . .335
HLS1.5S-X0      . . . . . . . . . . . . . . . . .322
HLS-15R      . . . . . . . . . . . . . . . . . . . .335
HLS-15R0      . . . . . . . . . . . . . . . . . . .322
HLS3S-X      . . . . . . . . . . . . . . . . . . . .335
HLS5S-X      . . . . . . . . . . . . . . . . . . . .335
HLS-75R0      . . . . . . . . . . . . . . . . . . .322
HLS-7R      . . . . . . . . . . . . . . . . . . . . .335
HLSP1.5S-X      . . . . . . . . . . . . . . . . .335
HLSP1.5S-X12      . . . . . . . . . . . . . . .322
HLSP3S-X12      . . . . . . . . . . . . . . . .322
HLSP5S-X      . . . . . . . . . . . . . . . . . .335
HLSP5S-X12      . . . . . . . . . . . . . . . .322
HLT2I-X     . . . . . . . . . . . . . . . . . . . . .335
HLT2I-X0     . . . . . . . . . . . . . . . . . . . .322
HLT3I-X     . . . . . . . . . . . . . . . . . . . . .335
HLT3I-X0     . . . . . . . . . . . . . . . . . . . .322
HLTP2I-X      . . . . . . . . . . . . . . . . . . .335
HLTP2I-X12      . . . . . . . . . . . . . . . . .322
HLTP3I-X      . . . . . . . . . . . . . . . . . . .335
HLTP3I-X12      . . . . . . . . . . . . . . . . .322
HS2X2YL6NM . . . . . . . . . . . . . . . . . .230
HSEC0.5-X  . . . . . . . . . . . . . . . . . . . .347
HSEC0.8-X  . . . . . . . . . . . . . . . . . . . .347
HSEC1.0-X  . . . . . . . . . . . . . . . . . . . .347
HSEC1.2.0-5-X  . . . . . . . . . . . . . . . . .347
HSEC1.5-5-X  . . . . . . . . . . . . . . . . . .347
HSEC2.0-5-X  . . . . . . . . . . . . . . . . . .347
HSEC4.0-2-X  . . . . . . . . . . . . . . . . . .347
HSTTV05-Y . . . . . . . . . . . . . . . . . . . .348
HSTTV06-Y . . . . . . . . . . . . . . . . . . . .348
HSTTV09-Y . . . . . . . . . . . . . . . . . . . .348
HSTTV100-Y . . . . . . . . . . . . . . . . . . .348
HSTTV12-Y . . . . . . . . . . . . . . . . . . . .348
HSTTV19-Y . . . . . . . . . . . . . . . . . . . .348
HSTTV25-Y . . . . . . . . . . . . . . . . . . . .348
HSTTV30-Y . . . . . . . . . . . . . . . . . . . .348
HSTTV38-Y . . . . . . . . . . . . . . . . . . . .348
HSTTV75-Y . . . . . . . . . . . . . . . . . . . .348
HTCT1000-1000-1      . . . . . . . . . . . .181
HTCT1000-250-1      . . . . . . . . . . . . .181
HTCT2-2-1      . . . . . . . . . . . . . . . . . .181
HTCT250-2-1      . . . . . . . . . . . . . . . .181
HTCT250-250-1      . . . . . . . . . . . . . .181
HTCT250-8-1      . . . . . . . . . . . . . . . .181
HTCT500-250-1      . . . . . . . . . . . . . .181
HTCT500-500-1      . . . . . . . . . . . . . .181
HTCT6-6-1      . . . . . . . . . . . . . . . . . .181

HTCT750-4/0-1      . . . . . . . . . . . . . . .181
HTCT750-750-1      . . . . . . . . . . . . . .181
HTCT8-8-1      . . . . . . . . . . . . . . . . . .181
HTMT

 . . . . . . . . . . . . . . . . . . . . . .344

I

IAEBGP . . . . . . . . . . . . . . . . . . . . . . . .24
IAEF617P-NMI  . . . . . . . . . . . . . . . . . .23
IAEF617P-NMI  . . . . . . . . . . . . . . . . . .23
IAEF7JMA  . . . . . . . . . . . . . . . . . . . . . .23
IAEFK54  . . . . . . . . . . . . . . . . . . . . . . .24
IAEFKSC . . . . . . . . . . . . . . . . . . . . . . .24
IAEFKSP  . . . . . . . . . . . . . . . . . . . . . . .24
IAEIP66  . . . . . . . . . . . . . . . . . . . . . . . .24
IAEOGP  . . . . . . . . . . . . . . . . . . . . . . .24
IAEPCBH  . . . . . . . . . . . . . . . . . . . . . .24
ICF10IW-X  . . . . . . . . . . . . . . . . . . . .317
ICF3IW-E  . . . . . . . . . . . . . . . . . . . . .317
ICF5IW-E  . . . . . . . . . . . . . . . . . . . . .317
ICFC10IW-X  . . . . . . . . . . . . . . . . . . .318
ICFC3IW-X  . . . . . . . . . . . . . . . . . . . .318
ICFC5IW-X  . . . . . . . . . . . . . . . . . . . .318
ICFX10IW-X  . . . . . . . . . . . . . . . . . . .319
ICFX3IW-X  . . . . . . . . . . . . . . . . . . . .319
ICFX5IW-X  . . . . . . . . . . . . . . . . . . . .319
IEKO30  . . . . . . . . . . . . . . . . . . . . . . . .24
ILT1.5I-M  . . . . . . . . . . . . . . . . . .324,334
ILT1M-M  . . . . . . . . . . . . . . . . . . .324,334
ILT2S-C  . . . . . . . . . . . . . . . . . . . . . . .334
ILT2S-M  . . . . . . . . . . . . . . . . . . .324,334
ILT3S-C  . . . . . . . . . . . . . . . . . . . . . . .334
ILT3S-M  . . . . . . . . . . . . . . . . . . .324,334
ILT4LH-TL  . . . . . . . . . . . . . . . . .324,334
ILT4S-C  . . . . . . . . . . . . . . . . . . . . . . .334
ILT4S-M  . . . . . . . . . . . . . . . . . . .324,334
ILT6LH-C  . . . . . . . . . . . . . . . . . .324,334
ISTPCH3MBL  . . . . . . . . . . . . . . . . . . .23
ISTPCHC1MBL  . . . . . . . . . . . . . . . . . .23
ISTPCHNC1MBL  . . . . . . . . . . . . . . . .23

J

JMCB-X . . . . . . . . . . . . . . . . . . . . . . .338
JMCMB25-1-X . . . . . . . . . . . . . . . . . .338
JMCMB25-3-X . . . . . . . . . . . . . . . . . .338
JMDWB-1-X  . . . . . . . . . . . . . . . . . . .339
JMDWB-3-X  . . . . . . . . . . . . . . . . . . .339
JMJH2W-X20  . . . . . . . . . . . . . . . . . .338
JMJH2-X20  . . . . . . . . . . . . . . . . . . . .338
JMSBCB87-1-X . . . . . . . . . . . . . . . . .339
JMSBCB87-3-X . . . . . . . . . . . . . . . . .339
JMTRB38-1-X  . . . . . . . . . . . . . . . . . .339
JMTRB38-3-X  . . . . . . . . . . . . . . . . . .339

K

KP1-C  . . . . . . . . . . . . . . . . . . . . . . . .185
KP2-L  . . . . . . . . . . . . . . . . . . . . . . . .185

L

LCA1/0-12F-X  . . . . . . . . . . . . . . . . . .167
LCA1/0-12H-X . . . . . . . . . . . . . . . . . .165
LCA1/0-12-X  . . . . . . . . . . . . . . . . . . .163
LCA1/0-14F-X  . . . . . . . . . . . . . . . . . .167
LCA1/0-14H-X . . . . . . . . . . . . . . . . . .165
LCA1/0-14-X  . . . . . . . . . . . . . . . . . . .163
LCA1/0-38F-X  . . . . . . . . . . . . . . . . . .167
LCA1/0-38H-X . . . . . . . . . . . . . . . . . .165
LCA1/0-38-X  . . . . . . . . . . . . . . . . . . .163
LCA1/0-56F-X  . . . . . . . . . . . . . . . . . .167

LCA1/0-56H-X . . . . . . . . . . . . . . . . . .165
LCA1/0-56-X  . . . . . . . . . . . . . . . . . . .163
LCA10-10-L . . . . . . . . . . . . . . . . . . . .163
LCA10-14F-L . . . . . . . . . . . . . . . . . . .167
LCA10-14H-L  . . . . . . . . . . . . . . . . . .165
LCA10-14-L . . . . . . . . . . . . . . . . . . . .163
LCA10-38-L . . . . . . . . . . . . . . . . . . . .163
LCA10-56-L . . . . . . . . . . . . . . . . . . . .163
LCA1-12-E  . . . . . . . . . . . . . . . . . . . .163
LCA1-12F-Q  . . . . . . . . . . . . . . . . . . .167
LCA1-12H-E  . . . . . . . . . . . . . . . . . . .165
LCA1-14-E  . . . . . . . . . . . . . . . . . . . .163
LCA1-14F-Q  . . . . . . . . . . . . . . . . . . .167
LCA1-14H-E  . . . . . . . . . . . . . . . . . . .165
LCA1-38-E  . . . . . . . . . . . . . . . . . . . .163
LCA1-38F-Q  . . . . . . . . . . . . . . . . . . .167
LCA1-38H-E  . . . . . . . . . . . . . . . . . . .165
LCA1-56-E  . . . . . . . . . . . . . . . . . . . .163
LCA1-56F-Q  . . . . . . . . . . . . . . . . . . .167
LCA1-56H-E  . . . . . . . . . . . . . . . . . . .165
LCA2/0-12F-X  . . . . . . . . . . . . . . . . . .167
LCA2/0-12H-X . . . . . . . . . . . . . . . . . .165
LCA2/0-12-X  . . . . . . . . . . . . . . . . . . .164
LCA2/0-14F-X  . . . . . . . . . . . . . . . . . .167
LCA2/0-14H-X . . . . . . . . . . . . . . . . . .165
LCA2/0-14-X  . . . . . . . . . . . . . . . . . . .164
LCA2/0-38F-X  . . . . . . . . . . . . . . . . . .167
LCA2/0-38H-X . . . . . . . . . . . . . . . . . .165
LCA2/0-38-X  . . . . . . . . . . . . . . . . . . .164
LCA2/0-56F-X  . . . . . . . . . . . . . . . . . .167
LCA2/0-56H-X . . . . . . . . . . . . . . . . . .165
LCA2/0-56-X  . . . . . . . . . . . . . . . . . . .164
LCA2-12F-Q  . . . . . . . . . . . . . . . . . . .167
LCA2-12H-Q  . . . . . . . . . . . . . . . . . . .165
LCA2-12-Q  . . . . . . . . . . . . . . . . . . . .163
LCA2-14F-Q  . . . . . . . . . . . . . . . . . . .167
LCA2-14H-Q  . . . . . . . . . . . . . . . . . . .165
LCA2-14-Q  . . . . . . . . . . . . . . . . . . . .163
LCA2-38F-Q  . . . . . . . . . . . . . . . . . . .167
LCA2-38H-Q  . . . . . . . . . . . . . . . . . . .165
LCA2-38-Q  . . . . . . . . . . . . . . . . . . . .163
LCA250-12F-X  . . . . . . . . . . . . . . . . .168
LCA250-12H-X  . . . . . . . . . . . . . . . . .166
LCA250-12-X  . . . . . . . . . . . . . . . . . .164
LCA250-14F-X  . . . . . . . . . . . . . . . . .168
LCA250-14H-X  . . . . . . . . . . . . . . . . .166
LCA250-14-X  . . . . . . . . . . . . . . . . . .164
LCA250-38F-X  . . . . . . . . . . . . . . . . .168
LCA250-38H-X  . . . . . . . . . . . . . . . . .166
LCA250-38-X  . . . . . . . . . . . . . . . . . .164
LCA250-56F-X  . . . . . . . . . . . . . . . . .168
LCA250-56H-X  . . . . . . . . . . . . . . . . .166
LCA250-56-X  . . . . . . . . . . . . . . . . . .164
LCA2-56F-Q  . . . . . . . . . . . . . . . . . . .167
LCA2-56H-Q  . . . . . . . . . . . . . . . . . . .165
LCA2-56-Q  . . . . . . . . . . . . . . . . . . . .163
LCA3/0-12F-X  . . . . . . . . . . . . . . . . . .167
LCA3/0-12H-X . . . . . . . . . . . . . . . . . .165
LCA3/0-12-X  . . . . . . . . . . . . . . . . . . .164
LCA3/0-14F-X  . . . . . . . . . . . . . . . . . .167
LCA3/0-14H-X . . . . . . . . . . . . . . . . . .165
LCA3/0-14-X  . . . . . . . . . . . . . . . . . . .164
LCA3/0-38F-X  . . . . . . . . . . . . . . . . . .167
LCA3/0-38H-X . . . . . . . . . . . . . . . . . .165
LCA3/0-38-X  . . . . . . . . . . . . . . . . . . .164
LCA3/0-56F-X  . . . . . . . . . . . . . . . . . .167
LCA3/0-56H-X . . . . . . . . . . . . . . . . . .165
LCA3/0-56-X  . . . . . . . . . . . . . . . . . . .164

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

Panduit-Pannet-html.html
background image

397

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

LCA300-12F-X  . . . . . . . . . . . . . . . . .168
LCA300-12H-X  . . . . . . . . . . . . . . . . .166
LCA300-12-X  . . . . . . . . . . . . . . . . . .164
LCA300-38F-X  . . . . . . . . . . . . . . . . .168
LCA300-38H-X  . . . . . . . . . . . . . . . . .166
LCA300-38-X  . . . . . . . . . . . . . . . . . .164
LCA300-56F-X  . . . . . . . . . . . . . . . . .168
LCA300-56H-X  . . . . . . . . . . . . . . . . .166
LCA300-56-X  . . . . . . . . . . . . . . . . . .164
LCA300-58F-X  . . . . . . . . . . . . . . . . .168
LCA300-58H-X  . . . . . . . . . . . . . . . . .166
LCA300-58-X  . . . . . . . . . . . . . . . . . .164
LCA300-78F-X  . . . . . . . . . . . . . . . . .168
LCA300-78H-X  . . . . . . . . . . . . . . . . .166
LCA300-78-X  . . . . . . . . . . . . . . . . . .164
LCA350-12F-X  . . . . . . . . . . . . . . . . .168
LCA350-12H-X  . . . . . . . . . . . . . . . . .166
LCA350-12-X  . . . . . . . . . . . . . . . . . .164
LCA350-38F-X  . . . . . . . . . . . . . . . . .168
LCA350-38H-X  . . . . . . . . . . . . . . . . .166
LCA350-38-X  . . . . . . . . . . . . . . . . . .164
LCA350-58F-X  . . . . . . . . . . . . . . . . .168
LCA350-58H-X  . . . . . . . . . . . . . . . . .166
LCA350-58-X  . . . . . . . . . . . . . . . . . .164
LCA350-78F-X  . . . . . . . . . . . . . . . . .168
LCA350-78H-X  . . . . . . . . . . . . . . . . .166
LCA350-78-X  . . . . . . . . . . . . . . . . . .164
LCA4/0-12F-X  . . . . . . . . . . . . . . . . . .168
LCA4/0-12H-X . . . . . . . . . . . . . . . . . .166
LCA4/0-12-X  . . . . . . . . . . . . . . . . . . .164
LCA4/0-14F-X  . . . . . . . . . . . . . . . . . .168
LCA4/0-14H-X . . . . . . . . . . . . . . . . . .166
LCA4/0-14-X  . . . . . . . . . . . . . . . . . . .164
LCA4/0-38F-X  . . . . . . . . . . . . . . . . . .168
LCA4/0-38H-X . . . . . . . . . . . . . . . . . .166
LCA4/0-38-X  . . . . . . . . . . . . . . . . . . .164
LCA4/0-56F-X  . . . . . . . . . . . . . . . . . .168
LCA4/0-56H-X . . . . . . . . . . . . . . . . . .166
LCA4/0-56-X  . . . . . . . . . . . . . . . . . . .164
LCA400-12-6 . . . . . . . . . . . . . . . . . . .164
LCA400-12F-6 . . . . . . . . . . . . . . . . . .168
LCA400-12H-X  . . . . . . . . . . . . . . . . .166
LCA400-38-6 . . . . . . . . . . . . . . . . . . .164
LCA400-38F-6 . . . . . . . . . . . . . . . . . .168
LCA400-38H-X  . . . . . . . . . . . . . . . . .166
LCA400-58-6 . . . . . . . . . . . . . . . . . . .164
LCA400-58H-X  . . . . . . . . . . . . . . . . .166
LCA400-78-6 . . . . . . . . . . . . . . . . . . .164
LCA400-78F-6 . . . . . . . . . . . . . . . . . .168
LCA400-78H-X  . . . . . . . . . . . . . . . . .166
LCA4-10F-L . . . . . . . . . . . . . . . . . . . .167
LCA4-10H-L  . . . . . . . . . . . . . . . . . . .165
LCA4-10-L . . . . . . . . . . . . . . . . . . . . .163
LCA4-14F-L . . . . . . . . . . . . . . . . . . . .167
LCA4-14H-L  . . . . . . . . . . . . . . . . . . .165
LCA4-14-L . . . . . . . . . . . . . . . . . . . . .163
LCA4-38F-L . . . . . . . . . . . . . . . . . . . .167
LCA4-38H-L  . . . . . . . . . . . . . . . . . . .165
LCA4-38-L . . . . . . . . . . . . . . . . . . . . .163
LCA4-56F-L . . . . . . . . . . . . . . . . . . . .167
LCA4-56H-L  . . . . . . . . . . . . . . . . . . .165
LCA4-56-L . . . . . . . . . . . . . . . . . . . . .163
LCA500-12-6 . . . . . . . . . . . . . . . . . . .164
LCA500-12F-6 . . . . . . . . . . . . . . . . . .168
LCA500-12H-X  . . . . . . . . . . . . . . . . .166
LCA500-1-6 . . . . . . . . . . . . . . . . . . . .164
LCA500-1F-6 . . . . . . . . . . . . . . . . . . .168
LCA500-1H-6  . . . . . . . . . . . . . . . . . .166

LCA500-34-6 . . . . . . . . . . . . . . . . . . .164
LCA500-34F-6 . . . . . . . . . . . . . . . . . .168
LCA500-38-6 . . . . . . . . . . . . . . . . . . .164
LCA500-38F-6 . . . . . . . . . . . . . . . . . .168
LCA500-38H-X  . . . . . . . . . . . . . . . . .166
LCA500-58-6 . . . . . . . . . . . . . . . . . . .164
LCA500-58H-X  . . . . . . . . . . . . . . . . .166
LCA500-78-6 . . . . . . . . . . . . . . . . . . .164
LCA500-78F-6 . . . . . . . . . . . . . . . . . .168
LCA500-78H-X  . . . . . . . . . . . . . . . . .166
LCA600-12-6 . . . . . . . . . . . . . . . . . . .164
LCA600-12-6 . . . . . . . . . . . . . . . . . . .164
LCA600-12F-6 . . . . . . . . . . . . . . . . . .168
LCA600-12H-6  . . . . . . . . . . . . . . . . .166
LCA600-58-6 . . . . . . . . . . . . . . . . . . .164
LCA600-58H-6  . . . . . . . . . . . . . . . . .166
LCA600-78-6 . . . . . . . . . . . . . . . . . . .164
LCA600-78F-6 . . . . . . . . . . . . . . . . . .168
LCA600-78H-6  . . . . . . . . . . . . . . . . .166
LCA6-10F-L . . . . . . . . . . . . . . . . . . . .167
LCA6-10H-L  . . . . . . . . . . . . . . . . . . .165
LCA6-10-L . . . . . . . . . . . . . . . . . . . . .163
LCA6-14F-L . . . . . . . . . . . . . . . . . . . .167
LCA6-14H-L  . . . . . . . . . . . . . . . . . . .165
LCA6-14-L . . . . . . . . . . . . . . . . . . . . .163
LCA6-38F-L . . . . . . . . . . . . . . . . . . . .167
LCA6-38H-L  . . . . . . . . . . . . . . . . . . .165
LCA6-38-L . . . . . . . . . . . . . . . . . . . . .163
LCA6-56F-L . . . . . . . . . . . . . . . . . . . .167
LCA6-56H-L  . . . . . . . . . . . . . . . . . . .165
LCA6-56-L . . . . . . . . . . . . . . . . . . . . .163
LCA8-10F-L . . . . . . . . . . . . . . . . . . . .167
LCA8-10H-L  . . . . . . . . . . . . . . . . . . .165
LCA8-10-L . . . . . . . . . . . . . . . . . . . . .163
LCA8-14F-L . . . . . . . . . . . . . . . . . . . .167
LCA8-14H-L  . . . . . . . . . . . . . . . . . . .165
LCA8-14-L . . . . . . . . . . . . . . . . . . . . .163
LCA8-38F-L . . . . . . . . . . . . . . . . . . . .167
LCA8-38H-L  . . . . . . . . . . . . . . . . . . .165
LCA8-38-L . . . . . . . . . . . . . . . . . . . . .163
LCA8-56F-L . . . . . . . . . . . . . . . . . . . .167
LCA8-56H-L  . . . . . . . . . . . . . . . . . . .165
LCA8-56-L . . . . . . . . . . . . . . . . . . . . .163
LCC1/0-12AW-X  . . . . . . . . . . . . . . . .173
LCC1/0-12DW-X  . . . . . . . . . . . . . . . .173
LCC1/0-14AW-X  . . . . . . . . . . . . . . . .173
LCC1/0-14BW-X  . . . . . . . . . . . . . . . .173
LCC1/0-14DW-X  . . . . . . . . . . . . . . . .173
LCC1/0-38DW-X  . . . . . . . . . . . . . . . .173
LCC1/0-38W-X  . . . . . . . . . . . . . . . . .173
LCC1000-12W-3  . . . . . . . . . . . . . . . .174
LCC1000-38DW-3 . . . . . . . . . . . . . . .174
LCC10-14AWH-L  . . . . . . . . . . . . . . .175
LCC10-14AW-L  . . . . . . . . . . . . . . . . .173
LCC10-14BWH-L  . . . . . . . . . . . . . . .175
LCC10-14BW-L  . . . . . . . . . . . . . . . . .173
LCC1-12W-E  . . . . . . . . . . . . . . . . . . .173
LCC1-14AW-E . . . . . . . . . . . . . . . . . .173
LCC1-14BW-E  . . . . . . . . . . . . . . . . .173
LCC1-38DW-E  . . . . . . . . . . . . . . . . .173
LCC1-56BW-E  . . . . . . . . . . . . . . . . .173
LCC1-56CW-E  . . . . . . . . . . . . . . . . .173
LCC2/0-12DW-X  . . . . . . . . . . . . . . . .174
LCC2/0-12W-X  . . . . . . . . . . . . . . . . .174
LCC2/0-14AW-X  . . . . . . . . . . . . . . . .174
LCC2/0-14BW-X  . . . . . . . . . . . . . . . .174
LCC2/0-38DW-X  . . . . . . . . . . . . . . . .174
LCC2/0-56DW-X  . . . . . . . . . . . . . . . .174

LCC2-10AW-Q  . . . . . . . . . . . . . . . . .173
LCC2-10AW-Q  . . . . . . . . . . . . . . . . .173
LCC2-10BW-Q  . . . . . . . . . . . . . . . . .173
LCC2-12W-Q  . . . . . . . . . . . . . . . . . .173
LCC2-14AW-Q  . . . . . . . . . . . . . . . . .173
LCC2-14BW-Q  . . . . . . . . . . . . . . . . .173
LCC2-14DW-Q  . . . . . . . . . . . . . . . . .173
LCC2-38BW-Q  . . . . . . . . . . . . . . . . .173
LCC2-38CW-Q  . . . . . . . . . . . . . . . . .173
LCC2-38DW-Q  . . . . . . . . . . . . . . . . .173
LCC2-38W-Q  . . . . . . . . . . . . . . . . . .173
LCC250-12DW-X  . . . . . . . . . . . . . . .174
LCC250-12W-X  . . . . . . . . . . . . . . . . .174
LCC250-38DW-X  . . . . . . . . . . . . . . .174
LCC250-56DW-X  . . . . . . . . . . . . . . .174
LCC2-56BW-Q  . . . . . . . . . . . . . . . . .173
LCC2-56CW-Q  . . . . . . . . . . . . . . . . .173
LCC3/0-12DW-X  . . . . . . . . . . . . . . . .174
LCC3/0-12W-X  . . . . . . . . . . . . . . . . .174
LCC3/0-14AW-X  . . . . . . . . . . . . . . . .174
LCC3/0-14BW-X  . . . . . . . . . . . . . . . .174
LCC3/0-38DW-X  . . . . . . . . . . . . . . . .174
LCC3/0-56DW-X  . . . . . . . . . . . . . . . .174
LCC300-12W-X  . . . . . . . . . . . . . . . . .174
LCC300-38DW-X  . . . . . . . . . . . . . . .174
LCC350-12W-X  . . . . . . . . . . . . . . . . .174
LCC350-14BW-X  . . . . . . . . . . . . . . .174
LCC4/0-12DW-X  . . . . . . . . . . . . . . . .174
LCC4/0-12W-X  . . . . . . . . . . . . . . . . .174
LCC4/0-14AW-X  . . . . . . . . . . . . . . . .174
LCC4/0-14BW-X  . . . . . . . . . . . . . . . .174
LCC4/0-38DW-X  . . . . . . . . . . . . . . . .174
LCC4/0-38W-X  . . . . . . . . . . . . . . . . .174
LCC4/0-56DW-X  . . . . . . . . . . . . . . . .174
LCC400-12W-6  . . . . . . . . . . . . . . . . .174
LCC400-14BW-6  . . . . . . . . . . . . . . . .174
LCC400-38DW-6 . . . . . . . . . . . . . . . .174
LCC4-10AW-L  . . . . . . . . . . . . . . . . . .173
LCC4-10BW-L  . . . . . . . . . . . . . . . . . .173
LCC4-14AW-L  . . . . . . . . . . . . . . . . . .173
LCC4-14BW-L  . . . . . . . . . . . . . . . . . .173
LCC4-38DW-L . . . . . . . . . . . . . . . . . .173
LCC500-12W-6  . . . . . . . . . . . . . . . . .174
LCC500-14BW-6  . . . . . . . . . . . . . . . .174
LCC500-38DBW-6  . . . . . . . . . . . . . .174
LCC600-12W-6  . . . . . . . . . . . . . . . . .174
LCC600-38DBW-6  . . . . . . . . . . . . . .174
LCC6-10AWH-L  . . . . . . . . . . . . . . . .175
LCC6-10AW-L  . . . . . . . . . . . . . . . . . .173
LCC6-10BWH-L  . . . . . . . . . . . . . . . .175
LCC6-10BW-L  . . . . . . . . . . . . . . . . . .173
LCC6-14AWH-L  . . . . . . . . . . . . . . . .175
LCC6-14AW-L  . . . . . . . . . . . . . . . . . .173
LCC6-14AW-L  . . . . . . . . . . . . . . . . . .173
LCC6-14BW-L  . . . . . . . . . . . . . . . . . .173
LCC6-14DW-L . . . . . . . . . . . . . . . . . .173
LCC6-38BW-L  . . . . . . . . . . . . . . . . . .173
LCC6-38CW-L . . . . . . . . . . . . . . . . . .173
LCC6-38DW-L . . . . . . . . . . . . . . . . . .173
LCC6-56BW-L  . . . . . . . . . . . . . . . . . .173
LCC750-12W-6  . . . . . . . . . . . . . . . . .174
LCC750-38DBW-6  . . . . . . . . . . . . . .174
LCC800-12W-6  . . . . . . . . . . . . . . . . .174
LCC8-10AWH-L  . . . . . . . . . . . . . . . .175
LCC8-10AW-L  . . . . . . . . . . . . . . . . . .173
LCC8-10BWH-L  . . . . . . . . . . . . . . . .175
LCC8-10BW-L  . . . . . . . . . . . . . . . . . .173
LCC8-14AWH-L  . . . . . . . . . . . . . . . .175

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

Panduit-Pannet-html.html
background image

398

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

LCC8-14AW-L  . . . . . . . . . . . . . . . . . .173
LCC8-14BWH-L  . . . . . . . . . . . . . . . .175
LCC8-14BW-L  . . . . . . . . . . . . . . . . . .173
LCC8-14DWH-L  . . . . . . . . . . . . . . . .175
LCC8-14DW-L . . . . . . . . . . . . . . . . . .173
LCC8-38DWH-L  . . . . . . . . . . . . . . . .175
LCC8-38DW-L . . . . . . . . . . . . . . . . . .173
LCD1/0-12F-X  . . . . . . . . . . . . . . . . . .172
LCD1/0-12H-X . . . . . . . . . . . . . . . . . .171
LCD1/0-12X  . . . . . . . . . . . . . . . . . . .170
LCD1/0-14AF-X . . . . . . . . . . . . . . . . .172
LCD1/0-14AF-X . . . . . . . . . . . . . . . . .172
LCD1/0-14AH-X  . . . . . . . . . . . . . . . .171
LCD1/0-14A-X . . . . . . . . . . . . . . . . . .170
LCD1/0-14BF-X . . . . . . . . . . . . . . . . .172
LCD1/0-14BH-X  . . . . . . . . . . . . . . . .171
LCD1/0-14BX  . . . . . . . . . . . . . . . . . .170
LCD1/0-38DF-X  . . . . . . . . . . . . . . . .172
LCD1/0-38DH-X  . . . . . . . . . . . . . . . .171
LCD1/0-38DX  . . . . . . . . . . . . . . . . . .170
LCD1/0-56CF-X  . . . . . . . . . . . . . . . .172
LCD1/0-56CH-X  . . . . . . . . . . . . . . . .171
LCD1/0-56C-X . . . . . . . . . . . . . . . . . .170
LCD1000-12-3 . . . . . . . . . . . . . . . . . .170
LCD10-10AF-L  . . . . . . . . . . . . . . . . .172
LCD10-10AH-L  . . . . . . . . . . . . . . . . .171
LCD10-10A-L  . . . . . . . . . . . . . . . . . .169
LCD10-14AF-L  . . . . . . . . . . . . . . . . .172
LCD10-14AH-L  . . . . . . . . . . . . . . . . .171
LCD10-14A-L  . . . . . . . . . . . . . . . . . .169
LCD10-14B-L  . . . . . . . . . . . . . . . . . .169
LCD10-14D-L  . . . . . . . . . . . . . . . . . .169
LCD10-38AH-L  . . . . . . . . . . . . . . . . .171
LCD10-38DF-L  . . . . . . . . . . . . . . . . .172
LCD10-38D-L  . . . . . . . . . . . . . . . . . .169
LCD1-12-E  . . . . . . . . . . . . . . . . . . . .169
LCD1-12F-E  . . . . . . . . . . . . . . . . . . .172
LCD1-12H-E  . . . . . . . . . . . . . . . . . . .171
LCD1-14A-E  . . . . . . . . . . . . . . . . . . .169
LCD1-14AF-E  . . . . . . . . . . . . . . . . . .172
LCD1-14AH-E  . . . . . . . . . . . . . . . . . .171
LCD1-14B-E  . . . . . . . . . . . . . . . . . . .169
LCD1-14BF-E  . . . . . . . . . . . . . . . . . .172
LCD1-14BH-E  . . . . . . . . . . . . . . . . . .171
LCD1-14CAF-E  . . . . . . . . . . . . . . . . .172
LCD1-14DF-E  . . . . . . . . . . . . . . . . . .172
LCD1-38AD-E  . . . . . . . . . . . . . . . . . .169
LCD1-38D-E  . . . . . . . . . . . . . . . . . . .169
LCD1-38DH-E  . . . . . . . . . . . . . . . . . .171
LCD1-56C-E  . . . . . . . . . . . . . . . . . . .169
LCD1-56CH-E  . . . . . . . . . . . . . . . . . .171
LCD2/0-12F-X  . . . . . . . . . . . . . . . . . .172
LCD2/0-12H-X . . . . . . . . . . . . . . . . . .171
LCD2/0-12-X  . . . . . . . . . . . . . . . . . . .170
LCD2/0-14AF-X . . . . . . . . . . . . . . . . .172
LCD2/0-14AF-X . . . . . . . . . . . . . . . . .172
LCD2/0-14AH-X  . . . . . . . . . . . . . . . .171
LCD2/0-14A-X . . . . . . . . . . . . . . . . . .170
LCD2/0-14BF-X . . . . . . . . . . . . . . . . .172
LCD2/0-14BH-X  . . . . . . . . . . . . . . . .171
LCD2/0-14B-X . . . . . . . . . . . . . . . . . .170
LCD2/0-38DF-X  . . . . . . . . . . . . . . . .172
LCD2/0-38DH-X  . . . . . . . . . . . . . . . .171
LCD2/0-38D-X . . . . . . . . . . . . . . . . . .170
LCD2/0-56CF-X  . . . . . . . . . . . . . . . .172
LCD2/0-56CH-X  . . . . . . . . . . . . . . . .171
LCD2/0-56C-X . . . . . . . . . . . . . . . . . .170
LCD2-12F-Q  . . . . . . . . . . . . . . . . . . .172

LCD2-12H-Q  . . . . . . . . . . . . . . . . . . .171
LCD2-12-Q  . . . . . . . . . . . . . . . . . . . .169
LCD2-14AF-Q  . . . . . . . . . . . . . . . . . .172
LCD2-14AH-Q . . . . . . . . . . . . . . . . . .171
LCD2-14A-Q  . . . . . . . . . . . . . . . . . . .169
LCD2-14BF-Q  . . . . . . . . . . . . . . . . . .172
LCD2-14BH-Q . . . . . . . . . . . . . . . . . .171
LCD2-14B-Q  . . . . . . . . . . . . . . . . . . .169
LCD2-14DF-Q  . . . . . . . . . . . . . . . . . .172
LCD2-14DH-Q . . . . . . . . . . . . . . . . . .171
LCD2-14D-Q  . . . . . . . . . . . . . . . . . . .169
LCD2-38AD-Q . . . . . . . . . . . . . . . . . .169
LCD2-38DF-Q  . . . . . . . . . . . . . . . . . .172
LCD2-38DH-Q . . . . . . . . . . . . . . . . . .171
LCD2-38D-Q  . . . . . . . . . . . . . . . . . . .169
LCD250-12D-X  . . . . . . . . . . . . . . . . .170
LCD250-12F-X  . . . . . . . . . . . . . . . . .172
LCD250-12H-X  . . . . . . . . . . . . . . . . .171
LCD250-38DF-X  . . . . . . . . . . . . . . . .172
LCD250-38DH-X  . . . . . . . . . . . . . . . .171
LCD250-38D-X  . . . . . . . . . . . . . . . . .170
LCD2-56BF-Q  . . . . . . . . . . . . . . . . . .172
LCD2-56BH-Q . . . . . . . . . . . . . . . . . .171
LCD2-56B-Q  . . . . . . . . . . . . . . . . . . .169
LCD3/0-12F-X  . . . . . . . . . . . . . . . . . .172
LCD3/0-12H-X . . . . . . . . . . . . . . . . . .171
LCD3/0-12-X  . . . . . . . . . . . . . . . . . . .170
LCD3/0-14AF-X . . . . . . . . . . . . . . . . .172
LCD3/0-14AF-X . . . . . . . . . . . . . . . . .172
LCD3/0-14AH-X  . . . . . . . . . . . . . . . .171
LCD3/0-14A-X . . . . . . . . . . . . . . . . . .170
LCD3/0-14BF-X . . . . . . . . . . . . . . . . .172
LCD3/0-14BH-X  . . . . . . . . . . . . . . . .171
LCD3/0-14B-X . . . . . . . . . . . . . . . . . .170
LCD3/0-38DF-X  . . . . . . . . . . . . . . . .172
LCD3/0-38DH-X  . . . . . . . . . . . . . . . .171
LCD3/0-38D-X . . . . . . . . . . . . . . . . . .170
LCD3/0-56CF-X  . . . . . . . . . . . . . . . .172
LCD3/0-56CH-X  . . . . . . . . . . . . . . . .171
LCD3/0-56C-X . . . . . . . . . . . . . . . . . .170
LCD300-12D-X  . . . . . . . . . . . . . . . . .170
LCD300-38D-X  . . . . . . . . . . . . . . . . .170
LCD350-14B-X  . . . . . . . . . . . . . . . . .170
LCD350-38D-X  . . . . . . . . . . . . . . . . .170
LCD4/0-12F-X  . . . . . . . . . . . . . . . . . .172
LCD4/0-12H-X . . . . . . . . . . . . . . . . . .171
LCD4/0-12-X  . . . . . . . . . . . . . . . . . . .170
LCD4/0-14A-X . . . . . . . . . . . . . . . . . .170
LCD4/0-14BF-X . . . . . . . . . . . . . . . . .172
LCD4/0-14BH-X  . . . . . . . . . . . . . . . .171
LCD4/0-14B-X . . . . . . . . . . . . . . . . . .170
LCD4/0-38DF-X  . . . . . . . . . . . . . . . .172
LCD4/0-38DH-X  . . . . . . . . . . . . . . . .171
LCD4/0-38D-X . . . . . . . . . . . . . . . . . .170
LCD4/0-56C-X . . . . . . . . . . . . . . . . . .170
LCD400-12-6 . . . . . . . . . . . . . . . . . . .170
LCD400-38D-6  . . . . . . . . . . . . . . . . .170
LCD4-10AF-L  . . . . . . . . . . . . . . . . . .172
LCD4-10A-L  . . . . . . . . . . . . . . . . . . .169
LCD4-14AF-L  . . . . . . . . . . . . . . . . . .172
LCD4-14AH-L  . . . . . . . . . . . . . . . . . .171
LCD4-14A-L  . . . . . . . . . . . . . . . . . . .169
LCD4-14BF-L  . . . . . . . . . . . . . . . . . .172
LCD4-14BH-L  . . . . . . . . . . . . . . . . . .171
LCD4-14B-L  . . . . . . . . . . . . . . . . . . .169
LCD4-14DF-L  . . . . . . . . . . . . . . . . . .172
LCD4-14DH-L  . . . . . . . . . . . . . . . . . .171
LCD4-14D-L  . . . . . . . . . . . . . . . . . . .169

LCD4-38AD-L  . . . . . . . . . . . . . . . . . .169
LCD4-38DF-L  . . . . . . . . . . . . . . . . . .172
LCD4-38D-L  . . . . . . . . . . . . . . . . . . .169
LCD4-38D-L  . . . . . . . . . . . . . . . . . . .169
LCD500-12-6 . . . . . . . . . . . . . . . . . . .170
LCD500-12E-6  . . . . . . . . . . . . . . . . .170
LCD500-14B-6  . . . . . . . . . . . . . . . . .170
LCD500-38D-6  . . . . . . . . . . . . . . . . .170
LCD600-12-6 . . . . . . . . . . . . . . . . . . .170
LCD600-38D-6  . . . . . . . . . . . . . . . . .170
LCD6-10AF-L  . . . . . . . . . . . . . . . . . .172
LCD6-10AH-L  . . . . . . . . . . . . . . . . . .171
LCD6-10A-L  . . . . . . . . . . . . . . . . . . .169
LCD6-14AF-L  . . . . . . . . . . . . . . . . . .172
LCD6-14AH-L  . . . . . . . . . . . . . . . . . .171
LCD6-14A-L  . . . . . . . . . . . . . . . . . . .169
LCD6-14BF-L  . . . . . . . . . . . . . . . . . .172
LCD6-14BH-L  . . . . . . . . . . . . . . . . . .171
LCD6-14B-L  . . . . . . . . . . . . . . . . . . .169
LCD6-14DF-L  . . . . . . . . . . . . . . . . . .172
LCD6-14DH-L  . . . . . . . . . . . . . . . . . .171
LCD6-14D-L  . . . . . . . . . . . . . . . . . . .169
LCD6-38AD-L  . . . . . . . . . . . . . . . . . .169
LCD6-38DF-L  . . . . . . . . . . . . . . . . . .172
LCD6-38DH-L  . . . . . . . . . . . . . . . . . .171
LCD6-38D-L  . . . . . . . . . . . . . . . . . . .169
LCD6-56DF-L  . . . . . . . . . . . . . . . . . .172
LCD6-56DH-L  . . . . . . . . . . . . . . . . . .171
LCD6-56D-L  . . . . . . . . . . . . . . . . . . .169
LCD750-12-6 . . . . . . . . . . . . . . . . . . .170
LCD8-10AF-L  . . . . . . . . . . . . . . . . . .172
LCD8-10AH-L  . . . . . . . . . . . . . . . . . .171
LCD8-10A-L  . . . . . . . . . . . . . . . . . . .169
LCD8-14AF-L  . . . . . . . . . . . . . . . . . .172
LCD8-14AH-L  . . . . . . . . . . . . . . . . . .171
LCD8-14A-L  . . . . . . . . . . . . . . . . . . .169
LCD8-14BF-L  . . . . . . . . . . . . . . . . . .172
LCD8-14BH-L  . . . . . . . . . . . . . . . . . .171
LCD8-14B-L  . . . . . . . . . . . . . . . . . . .169
LCD8-14DF-L  . . . . . . . . . . . . . . . . . .172
LCD8-14DH-L  . . . . . . . . . . . . . . . . . .171
LCD8-14D-L  . . . . . . . . . . . . . . . . . . .169
LCD8-38AD-L  . . . . . . . . . . . . . . . . . .169
LCD8-38DF-L  . . . . . . . . . . . . . . . . . .172
LCD8-38DH-L  . . . . . . . . . . . . . . . . . .171
LCD8-38D-L  . . . . . . . . . . . . . . . . . . .169
LD2P10  . . . . . . . . . . . . . . . . . . .303,313
LD2P10IW8-A  . . . . . . . . . . . . . . . . . .313
LD2P10IW10-A  . . . . . . . . . . . . . . . . .313
LD3IW6-A  . . . . . . . . . . . . . . . . . . . . .314
LD3IW8-A  . . . . . . . . . . . . . . . . . . . . .314
LD3IW10-A  . . . . . . . . . . . . . . . . . . . .314
LD5IW6-A  . . . . . . . . . . . . . . . . . . . . .314
LD5IW8-A  . . . . . . . . . . . . . . . . . . . . .314
LD5IW10-A  . . . . . . . . . . . . . . . . . . . .314
LD10IW6-A  . . . . . . . . . . . . . . . . . . . .314
LD10IW8-A  . . . . . . . . . . . . . . . . . . . .314
LD10IW10-A  . . . . . . . . . . . . . . . . . . .314
LDP3IW8-A  . . . . . . . . . . . . . . . . . . . .315
LDP3IW10-A  . . . . . . . . . . . . . . . . . . .315
LDP5IW8-A  . . . . . . . . . . . . . . . . . . . .315
LDP5IW10-A  . . . . . . . . . . . . . . . . . . .315
LDP10IW8-A  . . . . . . . . . . . . . . . . . . .315
LDP10IW10-A  . . . . . . . . . . . . . . . . . .315
LDS3IW10-A  . . . . . . . . . . . . . . . . . . .316
LDS5IW10-A  . . . . . . . . . . . . . . . . . . .316
LMD3IW-Q  . . . . . . . . . . . . . . . . . . . .316
LMD5IW-Q  . . . . . . . . . . . . . . . . . . . .316

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

Panduit-Pannet-html.html
background image

399

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

LS8  . . . . . . . . . . . . . . . . . . . . . . . . . .350
LS8-AC E/U . . . . . . . . . . . . . . . . . . . .350
LS8-CASE . . . . . . . . . . . . . . . . . . . . .350
LS8-CLN  . . . . . . . . . . . . . . . . . . . . . .350
LS8-IB  . . . . . . . . . . . . . . . . . . . . . . . .350
LS8-KIT  . . . . . . . . . . . . . . . . . . . . . . .350
LS8-PCKIT  . . . . . . . . . . . . . . . . . . . .350
LS8-WS . . . . . . . . . . . . . . . . . . . . . . .350

M

MFFPEBL  . . . . . . . . . . . . . . . . . . . . . .40
MLT1S-CP . . . . . . . . . . . . . . . . . . . . .342
MLT1S-CP316 . . . . . . . . . . . . . . . . . .342
MLT2.7S-CP  . . . . . . . . . . . . . . . . . . .342
MLT2.7WH-LP . . . . . . . . . . . . . . . . . .343
MLT2.7WH-LP316 . . . . . . . . . . . . . . .343
MLT2.7WLH-LP . . . . . . . . . . . . . . . . .343
MLT2.7WLH-LP316 . . . . . . . . . . . . . .343
MLT2.7WS-LP  . . . . . . . . . . . . . . . . . .343
MLT2.7WS-LP316  . . . . . . . . . . . . . . .343
MLT2H-LP  . . . . . . . . . . . . . . . . . . . . .342
MLT2H-LP316  . . . . . . . . . . . . . . . . . .342
MLT2LH-LP  . . . . . . . . . . . . . . . . . . . .342
MLT2LH-LP316  . . . . . . . . . . . . . . . . .342
MLT2S-CP . . . . . . . . . . . . . . . . . . . . .342
MLT2S-CP316 . . . . . . . . . . . . . . . . . .342
MLT4H-LP  . . . . . . . . . . . . . . . . . . . . .342
MLT4H-LP316  . . . . . . . . . . . . . . . . . .342
MLT4LH-LP  . . . . . . . . . . . . . . . . . . . .342
MLT4LH-LP316  . . . . . . . . . . . . . . . . .342
MLT4S-CP . . . . . . . . . . . . . . . . . . . . .342
MLT4S-CP316 . . . . . . . . . . . . . . . . . .342
MLT4WH-LP  . . . . . . . . . . . . . . . . . . .343
MLT4WH-LP316  . . . . . . . . . . . . . . . .343
MLT4WLH-LP  . . . . . . . . . . . . . . . . . .343
MLT4WS-LH316  . . . . . . . . . . . . . . . .343
MLT4WS-LP  . . . . . . . . . . . . . . . . . . .343
MLT4WS-LP316  . . . . . . . . . . . . . . . .343
MLT6H-LP  . . . . . . . . . . . . . . . . . . . . .342
MLT6H-LP316  . . . . . . . . . . . . . . . . . .342
MLT6LH-LP  . . . . . . . . . . . . . . . . . . . .342
MLT6LH-LP316  . . . . . . . . . . . . . . . . .342
MLT6S-CP . . . . . . . . . . . . . . . . . . . . .342
MLT6S-CP316 . . . . . . . . . . . . . . . . . .342
MLT6WH-LP  . . . . . . . . . . . . . . . . . . .343
MLT6WH-LP316  . . . . . . . . . . . . . . . .343
MLT6WLH-LP  . . . . . . . . . . . . . . . . . .343
MLT6WS-LH316  . . . . . . . . . . . . . . . .343
MLT6WS-LP  . . . . . . . . . . . . . . . . . . .343
MLT6WS-LP316  . . . . . . . . . . . . . . . .343
MLT8H-LP  . . . . . . . . . . . . . . . . . . . . .342
MLT8H-LP316  . . . . . . . . . . . . . . . . . .342
MLT8LH-LP  . . . . . . . . . . . . . . . . . . . .342
MLT8LH-LP316  . . . . . . . . . . . . . . . . .342
MLT8S-CP . . . . . . . . . . . . . . . . . . . . .342
MLT8S-CP316 . . . . . . . . . . . . . . . . . .342
MLT8WH-LP  . . . . . . . . . . . . . . . . . . .343
MLT8WH-LP316  . . . . . . . . . . . . . . . .343
MLT8WLH-LP  . . . . . . . . . . . . . . . . . .343
MLT8WS-LH316  . . . . . . . . . . . . . . . .343
MLT8WS-LP  . . . . . . . . . . . . . . . . . . .343
MLT8WS-LP316  . . . . . . . . . . . . . . . .343
MLTC2H-LP316  . . . . . . . . . . . . . . . .344
MLTC4H-LP316  . . . . . . . . . . . . . . . .344
MLTC6H-LP316  . . . . . . . . . . . . . . . .344
MLTC8H-LP316  . . . . . . . . . . . . . . . .344
MP588-C  . . . . . . . . . . . . . . . . . . . . . . .67
MP588-M . . . . . . . . . . . . . . . . . . . . . . . .8

MPI588T  . . . . . . . . . . . . . . . . . . . . . . .22
MPSI588T  . . . . . . . . . . . . . . . . . . . . . .22
MPT5-8  . . . . . . . . . . . . . . . . . . .

11,67

MWBA1  . . . . . . . . . . . . . . . . . . . . . . . .39
MWBA-2G  . . . . . . . . . . . . . . . . . . . . . .39

N

N050X0150CBC         . . . . . . . . . . . .352
N050X075CBC         . . . . . . . . . . . . .352
N100X125CBC         . . . . . . . . . . . . .352
N100X175CBC         . . . . . . . . . . . . .352
NC24S . . . . . . . . . . . . . . . . . . . . . . . . .51
NC24W  . . . . . . . . . . . . . . . . . . . . . . . .51
NCFK  . . . . . . . . . . . . . . . . . . . . . . . . .51
NCGK  . . . . . . . . . . . . . . . . . . . . . . . . .51
NCMH1-RFC . . . . . . . . . . . . . . . . . . .147
NCMH2-RFC . . . . . . . . . . . . . . . . . . .147
NCMH2  . . . . . . . . . . . . . . . . . . . . . . .147
NCMHAEF2  . . . . . . . . . . . . . . . .151,154
NCMHAEF4  . . . . . . . . . . . . . . . .151,154
NCMHF1  . . . . . . . . . . . . . . . . . . . . . .147
NCMHF2  . . . . . . . . . . . . . . . . . . . . . .147
NCMV12  . . . . . . . . . . . . . . . . . . . . . .137
NCMV8  . . . . . . . . . . . . . . . . . . . . . . .137
NCMV8RD        . . . . . . . . . . . . . . . . .137
NCMVEP

 . . . . . . . . . . . . . . . . . .137

NCSD  . . . . . . . . . . . . . . . . . . . . . . . . .51
NCSM12  . . . . . . . . . . . . . . . . . . . . . . .51
NF4PDR2X6K  . . . . . . . . . . . . . . . . . .135
NF4PR84  . . . . . . . . . . . . . . . . . . . . .135
NF4PSHLF19  . . . . . . . . . . . . . . . . . .135
NF4PVD2X5  . . . . . . . . . . . . . . . . . . .135
NFD484 . . . . . . . . . . . . . . . . . . . . . . .135
NFDR4X6K  . . . . . . . . . . . . . . . . . . . .135
NFEP . . . . . . . . . . . . . . . . . . . . . . . . .134
NFEP

 . . . . . . . . . . . . . . . . . . . . .132

NFLRB  . . . . . . . . . . . . . . . . . . . . . . .134
NFLRB      . . . . . . . . . . . . . . . . . . . . .132
NFR84 . . . . . . . . . . . . . . . . . . . . . . . .134
NFSHLF19X18  . . . . . . . . . . . . . . . . .134
NFSHLF19X18  . . . . . . . . . . . . . . . . .132
NFSHLF19X25  . . . . . . . . . . . . . . . . .134
NFSK . . . . . . . . . . . . . . . . . . . . . . . . .134
NFVD4X584  . . . . . . . . . . . . . . . . . . .132
NFVSM       . . . . . . . . . . . . . . . . . . . .132
NNC100X50LG2  . . . . . . . . . . . . . . . .247
NNC25X50LG2  . . . . . . . . . . . . . . . . .247
NNC37X37LG2  . . . . . . . . . . . . . . . . .247
NNC37X50LG2  . . . . . . . . . . . . . . . . .247
NNC37X75LG2  . . . . . . . . . . . . . . . . .247
NNC50X50LG2  . . . . . . . . . . . . . . . . .247
NNC50X75LG2  . . . . . . . . . . . . . . . . .247
NNC75X75LG2  . . . . . . . . . . . . . . . . .247
NR1-C  . . . . . . . . . . . . . . . . . . . . . . . .248
NR2WH-L  . . . . . . . . . . . . . . . . . . . . .239
NR4BL-L  . . . . . . . . . . . . . . . . . . . . . .239
NWSLC-2  . . . . . . . . . . . . . . . . . . . . .128
NWSLC-2Y  . . . . . . . . . . . . . . . . . . . .352
NWSLC-3  . . . . . . . . . . . . . . . . . . . . .128
NWSLC-3Y  . . . . . . . . . . . . . . . . . . . .352
NWSLC-7  . . . . . . . . . . . . . . . . . . . . .128
NWSLC-7Y  . . . . . . . . . . . . . . . . . . . .352

O

OCF10IW-X . . . . . . . . . . . . . . . . . . . .317
OCF3IW-E . . . . . . . . . . . . . . . . . . . . .317
OCF5IW-E . . . . . . . . . . . . . . . . . . . . .317
OCFC10IW-X  . . . . . . . . . . . . . . .313,319

OCFC3IW-X  . . . . . . . . . . . . . . . . . . .319
OCFC5IW-X  . . . . . . . . . . . . . . . . . . .319
OCFX10IW-X  . . . . . . . . . . . . . . . . . .318
OCFX3IW-X  . . . . . . . . . . . . . . . . . . .318
OCFX5IW-X  . . . . . . . . . . . . . . . . . . .318
OCTT  . . . . . . . . . . . . . . . . . . . . . . . .106
OF70FH2OB  . . . . . . . . . . . . . . . . . . .259
OF70FH4OB  . . . . . . . . . . . . . . . . . . .259
OF70FV2OB  . . . . . . . . . . . . . . . . . . .259
OF70FV4OB  . . . . . . . . . . . . . . . . . . .259
OFCR70ECOB  . . . . . . . . . . . . . . . . .258
OFCR70OB6 . . . . . . . . . . . . . . . . . . .257
OFCRC70OB6  . . . . . . . . . . . . . . . . .257
OFR20CCOB-X . . . . . . . . . . . . . . . . .259
OFR20CPOB8  . . . . . . . . . . . . . . . . .257
OFR20CROB  . . . . . . . . . . . . . . . . . .259
OFR20DMOB  . . . . . . . . . . . . . . . . . .258
OFR20DSOOB  . . . . . . . . . . . . . . . . .258
OFR20ECOB  . . . . . . . . . . . . . . . . . .259
OFR20ICOB  . . . . . . . . . . . . . . . . . . .259
OFR20LCOB . . . . . . . . . . . . . . . . . . .259
OFR20MPTOB  . . . . . . . . . . . . . . . . .258
OFR20OB6  . . . . . . . . . . . . . . . . . . . .257
OFR20OCOB  . . . . . . . . . . . . . . . . . .259
OFR20OFCR70OB1  . . . . . . . . . . . . .258
OFR20OFCR70OB2  . . . . . . . . . . . . .258
OFR20OFCR70OB4  . . . . . . . . . . . . .258
OFR20RAOB  . . . . . . . . . . . . . . . . . .259
OFR20SOOB  . . . . . . . . . . . . . . . . . .258
OFR20TOB  . . . . . . . . . . . . . . . . . . . .259
OFR20WEOB  . . . . . . . . . . . . . . . . . .259
OFVR5OB6  . . . . . . . . . . . . . . . . . . . .257
OM2  . . . . . . . . . . . . . . . . . . . . . . . .14,16
OM3  . . . . . . . . . . . . . . . . . . . . . . . .14,16

P

P10-10R-L . . . . . . . . . . . . . . . . . . . . .192
P10-12R-L . . . . . . . . . . . . . . . . . . . . .192
P10-14R-L . . . . . . . . . . . . . . . . . . . . .192
P10-38R-L . . . . . . . . . . . . . . . . . . . . .192
P10-56R-L . . . . . . . . . . . . . . . . . . . . .192
P110B1004R2  . . . . . . . . . . . . . . . . . . .78
P110B1004R4WJ  . . . . . . . . . . . . . . . .78
P110B1005R2  . . . . . . . . . . . . . . . . . . .78
P110B1005R4WJ  . . . . . . . . . . . . . . . .78
P110B100R2  . . . . . . . . . . . . . . . . . . . .78
P110B100R2B . . . . . . . . . . . . . . . . . . .78
P110B100R4B . . . . . . . . . . . . . . . . . . .78
P110B100R4WJ  . . . . . . . . . . . . . . . . .78
P110B100-X  . . . . . . . . . . . . . . . . . . . .81
P110B300-X  . . . . . . . . . . . . . . . . . . . .81
P110BW100-X . . . . . . . . . . . . . . . . . . .81
P110BW300-X . . . . . . . . . . . . . . . . . . .81
P110CB3-C  . . . . . . . . . . . . . . . . . . . . .80
P110CB3-X  . . . . . . . . . . . . . . . . . . . . .80
P110CB4-C  . . . . . . . . . . . . . . . . . . . . .80
P110CB4-X   . . . . . . . . . . . . . . . . . . . .80
P110CB5-C  . . . . . . . . . . . . . . . . . . . . .80
P110CB5-X  . . . . . . . . . . . . . . . . . . . . .80
P110JTW-X  . . . . . . . . . . . . . . . . . 75,81
P110JT-X  . . . . . . . . . . . . . . . . .

75,81

P110KB1004  . . . . . . . . . . . . . . . . . . . .77
P110KB1005  . . . . . . . . . . . . . . . . . . . .77
P110KB3004  . . . . . . . . . . . . . . . . . . . .77
P110KB3005  . . . . . . . . . . . . . . . . . . . .77
P110KT3004  . . . . . . . . . . . . . . . . . . . .79
P110KT3005  . . . . . . . . . . . . . . . . . . . .79
P110KT9004   . . . . . . . . . . . . . . . . . . .79

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

Panduit-Pannet-html.html
background image

400

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

P110KT9005  . . . . . . . . . . . . . . . . . . . .79
P110LH . . . . . . . . . . . . . . . . . .

81,82

P110PC1IG.5M  . . . . . . . . . . . . . . . . . .84
P110PC1IG1.5M  . . . . . . . . . . . . . . . . .84
P110PC1IG1M  . . . . . . . . . . . . . . . . . .84
P110PC1IG2M  . . . . . . . . . . . . . . . . . .84
P110PC1IG3M  . . . . . . . . . . . . . . . . . .84
P110PC1IG5M  . . . . . . . . . . . . . . . . . .84
P110PC1IG6M  . . . . . . . . . . . . . . . . . .84
P110PC1-X  . . . . . . . . . . . . . . . . . . . . .84
P110PC2IG.5M  . . . . . . . . . . . . . . . . . .84
P110PC2IG1.5M  . . . . . . . . . . . . . . . . .84
P110PC2IG1M  . . . . . . . . . . . . . . . . . .84
P110PC2IG2M  . . . . . . . . . . . . . . . . . .84
P110PC2IG3M  . . . . . . . . . . . . . . . . . .84
P110PC2IG5M  . . . . . . . . . . . . . . . . . .84
P110PC2-X  . . . . . . . . . . . . . . . . . . . . .84
P110PC3-X  . . . . . . . . . . . . . . . . . . . . .84
P110PC4IG1M  . . . . . . . . . . . . . . . . . .84
P110PC4IG1MA  . . . . . . . . . . . . . . . . .84
P110PC4IG1MB  . . . . . . . . . . . . . . . . .84
P110PC4IG2M  . . . . . . . . . . . . . . . . . .84
P110PC4IG2MA  . . . . . . . . . . . . . . . . .84
P110PC4IG2MB  . . . . . . . . . . . . . . . . .84
P110PC4IG3M  . . . . . . . . . . . . . . . . . .84
P110PC4IG3MA  . . . . . . . . . . . . . . . . .84
P110PC4IG3MB  . . . . . . . . . . . . . . . . .84
P110PC4IG5M  . . . . . . . . . . . . . . . . . .84
P110PC4IG5MA  . . . . . . . . . . . . . . . . .84
P110PC4IG5MB  . . . . . . . . . . . . . . . . .84
P110PC4-X  . . . . . . . . . . . . . . . . . . . . .84
P110T300  . . . . . . . . . . . . . . . . . . . . . .79
P110T900  . . . . . . . . . . . . . . . . . . . . . .79
P110TB300  . . . . . . . . . . . . . . . . . . . . .80
P110TB900  . . . . . . . . . . . . . . . . . . . . .80
P110VCM  . . . . . . . . . . . . . . . . . . . . . .79
P110VCM300  . . . . . . . . . . . . . . . . . . .79
P110VCM900  . . . . . . . . . . . . . . . . . . .79
P14-12R-L . . . . . . . . . . . . . . . . . . . . .192
P18-12R-C  . . . . . . . . . . . . . . . . . . . .192
PDB110M  . . . . . . . . . . . . . . . . . . . . . .83
PDH110M  . . . . . . . . . . . . . . . . . . . . . .83
PDT110  . . . . . . . . . . . . . . . . . . . . . . . .83
PDT110M  . . . . . . . . . . . . . . . . . . . . . .83
PDTH110 . . . . . . . . . . . . . . . . . . . . . . .83
PEB1  . . . . . . . . . . . . . . . . . . . . . . . . .143
PEB2  . . . . . . . . . . . . . . . . . . . . . . . . .143
PEB22  . . . . . . . . . . . . . . . . . . . . . . . .143
PEB44  . . . . . . . . . . . . . . . . . . . . . . . .143
PFC5504LG-E . . . . . . . . . . . . . . . . . . . .9
PFC5504LG-ED  . . . . . . . . . . . . . . . . .85
PFC6004LG-ED . . . . . . . . . . . .

11,86

PFL5504DG-E . . . . . . . . . . . . . . . . . . . .9
PFL5504DG-ED  . . . . . . . . . . . . . . . . .85
PFL6004DG-ED . . . . . . . . . . . .

11,86

PFX-0  . . . . . . . . . . . . . .106,107,108,109
PGK . . . . . . . . . . . . . . . . . . . . . . . . . . .62
PGK96 . . . . . . . . . . . . . . . . . . . . . . . . .62
PGKE  . . . . . . . . . . . . . . . . . . . . . . . . .62
PGKE96  . . . . . . . . . . . . . . . . . . . . . . .62
PL2M2S-D . . . . . . . . . . . . . . . . . . . . .332
PL2M2S-L  . . . . . . . . . . . . . . . . .327,332
PL3M2S-D . . . . . . . . . . . . . . . . . . . . .332
PL3M2S-L  . . . . . . . . . . . . . . . . .327,332
PLC1.5I-S8-C . . . . . . . . . . . . . . .326,331
PLC1M-S4-C  . . . . . . . . . . . . . . .326,331
PLC2H-S25-L . . . . . . . . . . . . . . .326,331
PLC2S-S10-C  . . . . . . . . . . . . . .326,331

PLC2S-S6-C  . . . . . . . . . . . . . . .326,331
PLC3S-S10-C  . . . . . . . . . . . . . .326,331
PLC4H-S25-L . . . . . . . . . . . . . . .326,331
PLC4S-S10-C  . . . . . . . . . . . . . .326,331
PLF1MB-C  . . . . . . . . . . . . . . . . .327,331
PLF1M-C  . . . . . . . . . . . . . . . . . .327,331
PLM1M-C  . . . . . . . . . . . . . . . . . .327,331
PLM2M-C  . . . . . . . . . . . . . . . . . .327,331
PLM2S-C  . . . . . . . . . . . . . . . . . .327,331
PLM4S-C  . . . . . . . . . . . . . . . . . .327,331
PLP1.5I-C  . . . . . . . . . . . . . . . . . . . . .332
PLP1.5I-M  . . . . . . . . . . . . . . . . . . . . .332
PLP1.5S-M  . . . . . . . . . . . . . . . . . . . .332
PLP1S-M . . . . . . . . . . . . . . . . . . . . . .332
PLP2S-C  . . . . . . . . . . . . . . . . . . . . . .332
PLP2S-M . . . . . . . . . . . . . . . . . . . . . .332
PLT.1SM-M  . . . . . . . . . . . . . . . . . . . .332
PLT.6SM-C  . . . . . . . . . . . . . . . . . . . .332
PLT.6SM-M  . . . . . . . . . . . . . . . . . . . .332
PLT.7M-C  . . . . . . . . . . . . . . . . . . . . .332
PLT.7SM-M  . . . . . . . . . . . . . . . . . . . .332
PLT1.5I-C  . . . . . . . . . . . . . . . . . .325,332
PLT1.5I-M  . . . . . . . . . . . . . . . . . . . . .332
PLT1.5M-C  . . . . . . . . . . . . . . . . .325,332
PLT1.5M-M  . . . . . . . . . . . . . . . . . . . .332
PLT1.5M-XMR . . . . . . . . . . . . . . . . . .332
PLT1.5S-C  . . . . . . . . . . . . . . . . .325,332
PLT1.5S-M  . . . . . . . . . . . . . . . . . . . .332
PLT10LH-C  . . . . . . . . . . . . . . . . . . . .332
PLT10LH-L  . . . . . . . . . . . . . . . . .325,332
PLT13H-C  . . . . . . . . . . . . . . . . . . . . .332
PLT13H-Q  . . . . . . . . . . . . . . . . .325,332
PLT1M-C  . . . . . . . . . . . . . . . . . .325,332
PLT1M-C702  . . . . . . . . . . . . . . . . . . .326
PLT1M-XMR  . . . . . . . . . . . . . . . . . . .332
PLT1S-C . . . . . . . . . . . . . . . . . . .325,332
PLT1S-M  . . . . . . . . . . . . . . . . . . . . . .332
PLT2.5H-L  . . . . . . . . . . . . . . . . .325,332
PLT2.5H-TL  . . . . . . . . . . . . . . . . . . . .332
PLT2.5I-C  . . . . . . . . . . . . . . . . . . . . .325
PLT2.5I-M  . . . . . . . . . . . . . . . . . . . . .332
PLT2.5S-C  . . . . . . . . . . . . . . . . .325,332
PLT2.5S-M  . . . . . . . . . . . . . . . . . . . .332
PLT2EH-C  . . . . . . . . . . . . . . . . . . . . .332
PLT2H-TL  . . . . . . . . . . . . . . . . . . . . .332
PLT2I-C  . . . . . . . . . . . . . . . . . . .325,332
PLT2I-M . . . . . . . . . . . . . . . . . . . . . . .332
PLT2M-C  . . . . . . . . . . . . . . . . . .325,332
PLT2M-M . . . . . . . . . . . . . . . . . . . . . .332
PLT2S-C . . . . . . . . . . . . . . . . . . .325,332
PLT2S-C702  . . . . . . . . . . . . . . . . . . .326
PLT2S-M  . . . . . . . . . . . . . . . . . . . . . .332
PLT3EH-NB-C  . . . . . . . . . . . . . . . . . .332
PLT3H-L  . . . . . . . . . . . . . . . . . . .325,332
PLT3H-TL  . . . . . . . . . . . . . . . . . . . . .332
PLT3I-C  . . . . . . . . . . . . . . . . . . .325,332
PLT3I-M . . . . . . . . . . . . . . . . . . . . . . .332
PLT3S-C . . . . . . . . . . . . . . . . . . .325,332
PLT3S-C702  . . . . . . . . . . . . . . . . . . .326
PLT3S-M  . . . . . . . . . . . . . . . . . . . . . .332
PLT4H-L  . . . . . . . . . . . . . . . . . . .325,332
PLT4H-TL  . . . . . . . . . . . . . . . . . . . . .332
PLT4I-C  . . . . . . . . . . . . . . . . . . .325,332
PLT4I-M . . . . . . . . . . . . . . . . . . . . . . .332
PLT4S-C . . . . . . . . . . . . . . . . . . .325,332
PLT4S-M  . . . . . . . . . . . . . . . . . . . . . .332
PLT5EH-C  . . . . . . . . . . . . . . . . . . . . .332
PLT5EH-NB-C  . . . . . . . . . . . . . . . . . .332

PLT5EH-Q  . . . . . . . . . . . . . . . . .325,332
PLT5H-C  . . . . . . . . . . . . . . . . . . . . . .332
PLT5S-C . . . . . . . . . . . . . . . . . . .325,332
PLT5S-M  . . . . . . . . . . . . . . . . . . . . . .332
PLT6EH-C  . . . . . . . . . . . . . . . . . . . . .332
PLT6EH-NB-C  . . . . . . . . . . . . . . . . . .332
PLT6EH-NB-C  . . . . . . . . . . . . . . . . . .332
PLT6EH-Q  . . . . . . . . . . . . . . . . .325,332
PLT6H-C  . . . . . . . . . . . . . . . . . . . . . .332
PLT6H-L  . . . . . . . . . . . . . . . . . . .325,332
PLT6LH-C  . . . . . . . . . . . . . . . . . . . . .332
PLT6LH-L  . . . . . . . . . . . . . . . . . .325,332
PLT7LH-C  . . . . . . . . . . . . . . . . . . . . .332
PLT7LH-L  . . . . . . . . . . . . . . . . . .325,332
PLT8EH-C  . . . . . . . . . . . . . . . . . . . . .332
PLT8H-C  . . . . . . . . . . . . . . . . . . . . . .332
PLT8H-L  . . . . . . . . . . . . . . . . . . .325,332
PLT8LH-C  . . . . . . . . . . . . . . . . . . . . .332
PLT9LH-C  . . . . . . . . . . . . . . . . . . . . .332
PLT9LH-L  . . . . . . . . . . . . . . . . . .325,332
PN10-10R-L  . . . . . . . . . . . . . . . . . . .191
PN10-10RX-L  . . . . . . . . . . . . . . . . . .191
PN10-12R-L  . . . . . . . . . . . . . . . . . . .191
PN10-14R-L  . . . . . . . . . . . . . . . . . . .191
PN10-14RX-L  . . . . . . . . . . . . . . . . . .191
PN10-38R-L  . . . . . . . . . . . . . . . . . . .191
PN10-38RX-L  . . . . . . . . . . . . . . . . . .191
PN10-56R-L  . . . . . . . . . . . . . . . . . . .191
PN10-56RX-L  . . . . . . . . . . . . . . . . . .191
PN14-12R-L  . . . . . . . . . . . . . . . . . . .191
PN18-12R-C  . . . . . . . . . . . . . . . . . . .191
PPF2S-S25-V  . . . . . . . . . . . . . . . . . .153
PPF2S-S25-V69  . . . . . . . . . . . . . . . .153
PPF2SV-S25-V  . . . . . . . . . . . . . . . . .153
PPF2SV-S25-V69  . . . . . . . . . . . . . . .153
PRD12 . . . . . . . . . . . . . . . . . . . . . . . .138
PRD6 . . . . . . . . . . . . . . . . . . . . . . . . .138
PRD8 . . . . . . . . . . . . . . . . . . . . . . . . .138
PREP  . . . . . . . . . . . . . . . . . . . . . . . .138
PROG-CCCD  . . . . . . . . . . . . . . . . . .355
PROG-EMCD3  . . . . . . . . . . . . . . . . .355
PRSP7  . . . . . . . . . . . . . . . . . . . . . . .138
PRV12  . . . . . . . . . . . . . . . . . . . . . . . .138
PRV6  . . . . . . . . . . . . . . . . . . . . . . . . .138
PRV8  . . . . . . . . . . . . . . . . . . . . . . . . .138
PRVF12 . . . . . . . . . . . . . . . . . . . . . . .138
PRVF6 . . . . . . . . . . . . . . . . . . . . . . . .138
PRVF8 . . . . . . . . . . . . . . . . . . . . . . . .138
PSC7004LG-ED  . . . . . . . . . . . . . . . . .13
PSFC5504LG-ED  . . . . . . . . . . . . . . . .85
PSFL5504DG-ED  . . . . . . . . . . . . . . . .85
PSL7004DG-ED  . . . . . . . . . . . . . . . . .13
PUC5504LG-E  . . . . . . . . . . . . . . . . . .85
PUC5504LG-ED  . . . . . . . . . . . . . . . . . .8
PUL5504DG-ED  . . . . . . . . . . . . . . . . . .8
PUL5504WH-E  . . . . . . . . . . . . . . . . . .85
PUL6X04WH-E  . . . . . . . . . . . .

12,86

PV10-10R-L  . . . . . . . . . . . . . . . . . . .192
PV10-10RX-L  . . . . . . . . . . . . . . . . . .192
PV10-12R-L  . . . . . . . . . . . . . . . . . . .192
PV10-14R-L  . . . . . . . . . . . . . . . . . . .192
PV10-14RX-L  . . . . . . . . . . . . . . . . . .192
PV10-38R-L  . . . . . . . . . . . . . . . . . . .192
PV10-38RX-L  . . . . . . . . . . . . . . . . . .192
PV10-56R-L  . . . . . . . . . . . . . . . . . . .192
PV10-56RX-L  . . . . . . . . . . . . . . . . . .192
PV14-12R-L  . . . . . . . . . . . . . . . . . . .192
PV18-12R-C  . . . . . . . . . . . . . . . . . . .192

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

Panduit-Pannet-html.html
background image

401

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

PW50F-T . . . . . . . . . . . . . . . . . . . . . .345
PW50F-T20 . . . . . . . . . . . . . . . . . . . .345
PW75F-C  . . . . . . . . . . . . . . . . . . . . .345
PW75F-C20  . . . . . . . . . . . . . . . . . . .345
PWMS-H25-C  . . . . . . . . . . . . . . . . . .337
PWT100  . . . . . . . . . . . . . . . . . . . . . .345
PWT150  . . . . . . . . . . . . . . . . . . . . . .345
PWT50  . . . . . . . . . . . . . . . . . . . . . . .345
PWT75  . . . . . . . . . . . . . . . . . . . . . . .345
PZAEFAN  . . . . . . . . . . . . . . . . . . . . . .50
PZAELOCK  . . . . . . . . . . . . . . . . . . . . .50
PZAEWM3  . . . . . . . . . . . . . . . . . . . . .50
PZB4  . . . . . . . . . . . . . . . . . . . . . . . . . .50
PZB4-FC  . . . . . . . . . . . . . . . . . . . . . . .50
PZB4-HC . . . . . . . . . . . . . . . . . . . . . . .50
PZBPPB  . . . . . . . . . . . . . . . . . . . . . . .50
PZWIFICB  . . . . . . . . . . . . . . . . . . . . . .51
PZWIFIE  . . . . . . . . . . . . . . . . . . . . . . .51

R

RAEFXIW-X  . . . . . . . . . . . . . . . .318,319
RAF10IW-X  . . . . . . . . . . . . . . . .313,317
RAF3IW-E  . . . . . . . . . . . . . . . . . . . . .317
RAF5IW-E  . . . . . . . . . . . . . . . . . . . . .317
RAFC10IW-X  . . . . . . . . . . . . . . . . . .318
RAFC3IW-X  . . . . . . . . . . . . . . . . . . .318
RAFC5IW-X  . . . . . . . . . . . . . . . . . . .318
RAFX10IW-X . . . . . . . . . . . . . . . . . . .319
RAFX3IW-X . . . . . . . . . . . . . . . . . . . .319
RAFX5IW-X . . . . . . . . . . . . . . . . . . . .319
REC24L  . . . . . . . . . . . . . . . . . . .154,157
RF10X3IW-X  . . . . . . . . . . . . . . . . . . .317
RF10X5IW-X  . . . . . . . . . . . . . . . . . . .317
RF5X3IW-E  . . . . . . . . . . . . . . . . . . . .317
RFX103W-X  . . . . . . . . . . . . . . . .318,319
RFX105W-X  . . . . . . . . . . . . . . . .318,319
RFX53IW-X  . . . . . . . . . . . . . . . .318,319
RSC1/0-4-X . . . . . . . . . . . . . . . . . . . .184
RSC1/0-6-X . . . . . . . . . . . . . . . . . . . .184
RSC2/0-4-X . . . . . . . . . . . . . . . . . . . .184
RSC2/0-6-X . . . . . . . . . . . . . . . . . . . .184
RSC2-4-Q  . . . . . . . . . . . . . . . . . . . . .184
RSC2-6-Q  . . . . . . . . . . . . . . . . . . . . .184
RSC4/0-4-X . . . . . . . . . . . . . . . . . . . .184
RSC4/0-6-X . . . . . . . . . . . . . . . . . . . .184
RSC4-6-L  . . . . . . . . . . . . . . . . . . . . .184
RSC750-4/0-6  . . . . . . . . . . . . . . . . . .184
RSC750-X350-6  . . . . . . . . . . . . . . . .184
RSC750-X4/0-6 . . . . . . . . . . . . . . . . .184
RSCK1/0-4-1 . . . . . . . . . . . . . . . . . . .184
RSCK1/0-6-1 . . . . . . . . . . . . . . . . . . .184
RSCK2/0-4-1 . . . . . . . . . . . . . . . . . . .184
RSCK2/0-6-1 . . . . . . . . . . . . . . . . . . .184
RSCK2-4-1  . . . . . . . . . . . . . . . . . . . .184
RSCK2-6-1  . . . . . . . . . . . . . . . . . . . .184
RSCK4/0-4-1 . . . . . . . . . . . . . . . . . . .184
RSCK4/0-6-1 . . . . . . . . . . . . . . . . . . .184
RSCK4-6-1  . . . . . . . . . . . . . . . . . . . .184
RSCK750-4/0-1 . . . . . . . . . . . . . . . . .184
RSCK750-X350-1  . . . . . . . . . . . . . . .184
RSCK750-X4/0-1  . . . . . . . . . . . . . . .184
RSCKX750-4/0-1  . . . . . . . . . . . . . . .184
RSCKX750-750-1  . . . . . . . . . . . . . . .184
RSCX750-4/0-3 . . . . . . . . . . . . . . . . .184
RSCX750-750-3  . . . . . . . . . . . . . . . .184

S

S050X0125VAC   . . . . . . . . . . . . . . . .351

S050X0150VAC   . . . . . . . . . . . . . . . .351
S050X075VAC   . . . . . . . . . . . . . . . . .351
S100X0125VAC   . . . . . . . . . . . . . . . .351
S100X0150VAC   . . . . . . . . . . . . . . . .351
S100X0160VAC   . . . . . . . . . . . . . . . .352
S100X0220VAC   . . . . . . . . . . . . . . . .352
S100X0225VAC   . . . . . . . . . . . . . . . .351
S100X0400VAC   . . . . . . . . . . . . . . . .351
S100X0650VAC   . . . . . . . . . . . . . . . .351
S100X075VAC   . . . . . . . . . . . . . . . . .351
S100X125FAJ  . . . . . . . . . . . . . . . . . .351
S100X150FAJ  . . . . . . . . . . . . . . . . . .351
S100X150YAC  . . . . . . . . . . . . . . . . . .23
S100X150YAJ  . . . . . . . . . . . . . . . . . . .23
S100X160FAJ  . . . . . . . . . . . . . . . . . .351
S100X225FAJ  . . . . . . . . . . . . . . . . . .351
S100X400FAJ  . . . . . . . . . . . . . . . . . .351
S1224-C   . . . . . . . . . . . . . . . . . . . . . .142
S200X225FAJ  . . . . . . . . . . . . . . . . . .351
S200X400FAJ  . . . . . . . . . . . . . . . . . .351
S2X2YL6NM  . . . . . . . . . . . . . . . . . . .236
S4X4YL6NM  . . . . . . . . . . . . . . . . . . .236
SACS50-T100  . . . . . . . . . . . . . . . . . .330
SA-FRVD01  . . . . . . . . . . . . . . .

15,17

SCL1/0-X . . . . . . . . . . . . . . . . . . . . . .179
SCL1000-3  . . . . . . . . . . . . . . . . . . . .179
SCL1-E  . . . . . . . . . . . . . . . . . . . . . . .179
SCL2/0-X . . . . . . . . . . . . . . . . . . . . . .179
SCL250-X  . . . . . . . . . . . . . . . . . . . . .179
SCL2-Q  . . . . . . . . . . . . . . . . . . . . . . .179
SCL3/0-X . . . . . . . . . . . . . . . . . . . . . .179
SCL350-X  . . . . . . . . . . . . . . . . . . . . .179
SCL4/0-X . . . . . . . . . . . . . . . . . . . . . .179
SCL400-6  . . . . . . . . . . . . . . . . . . . . .179
SCL400-X  . . . . . . . . . . . . . . . . . . . . .179
SCL4-L  . . . . . . . . . . . . . . . . . . . . . . .179
SCL500-6  . . . . . . . . . . . . . . . . . . . . .179
SCL600-6  . . . . . . . . . . . . . . . . . . . . .179
SCL6-L  . . . . . . . . . . . . . . . . . . . . . . .179
SCL750-6  . . . . . . . . . . . . . . . . . . . . .179
SCL8-L  . . . . . . . . . . . . . . . . . . . . . . .179
SCS1/0-X  . . . . . . . . . . . . . . . . . . . . .179
SCS1000-3  . . . . . . . . . . . . . . . . . . . .179
SCS1-E  . . . . . . . . . . . . . . . . . . . . . . .179
SCS2/0-X  . . . . . . . . . . . . . . . . . . . . .179
SCS250-X  . . . . . . . . . . . . . . . . . . . . .179
SCS2-Q . . . . . . . . . . . . . . . . . . . . . . .179
SCS3/0-X  . . . . . . . . . . . . . . . . . . . . .179
SCS300-X  . . . . . . . . . . . . . . . . . . . . .179
SCS350-X  . . . . . . . . . . . . . . . . . . . . .179
SCS4/0-X  . . . . . . . . . . . . . . . . . . . . .179
SCS400-6  . . . . . . . . . . . . . . . . . . . . .179
SCS4-L  . . . . . . . . . . . . . . . . . . . . . . .179
SCS500-6  . . . . . . . . . . . . . . . . . . . . .179
SCS600-6  . . . . . . . . . . . . . . . . . . . . .179
SCS6-L  . . . . . . . . . . . . . . . . . . . . . . .179
SCS750-6  . . . . . . . . . . . . . . . . . . . . .179
SCS8-L  . . . . . . . . . . . . . . . . . . . . . . .179
SD2H6 . . . . . . . . . . . . . . . . . . . . . . . .248
SD3H6 . . . . . . . . . . . . . . . . . . . . . . . .248
SD4H6 . . . . . . . . . . . . . . . . . . . . . . . .248
SLCT-IG   . . . . . . . . . . . . . . . . . . . . . . .69
SLCT-OR . . . . . . . . . . . . . . . . . . . . . . .69
SLCT-WH  . . . . . . . . . . . . . . . . . . . . . .69
SLCT-YL  . . . . . . . . . . . . . . . . . . . . . . .69
SP1-1/0-L  . . . . . . . . . . . . . . . . . . . . .182
SP1-1/0-L-L . . . . . . . . . . . . . . . . . . . .182
SP1-2/0L-Q  . . . . . . . . . . . . . . . . . . . .182

SP1-2/0-Q  . . . . . . . . . . . . . . . . . . . . .182
SP1-2-C  . . . . . . . . . . . . . . . . . . . . . .182
SP1-2L-C  . . . . . . . . . . . . . . . . . . . . .182
SP1-350-12  . . . . . . . . . . . . . . . . . . . .182
SP1-350L-12  . . . . . . . . . . . . . . . . . . .182
SP1-3-C  . . . . . . . . . . . . . . . . . . . . . .182
SP1-3L-C  . . . . . . . . . . . . . . . . . . . . .182
SP1-4/0L-Q  . . . . . . . . . . . . . . . . . . . .182
SP1-4/0-Q  . . . . . . . . . . . . . . . . . . . . .182
SP1-4-C  . . . . . . . . . . . . . . . . . . . . . .182
SP1-4L-C  . . . . . . . . . . . . . . . . . . . . .182
SP1-500-12  . . . . . . . . . . . . . . . . . . . .182
SP1-500L-12  . . . . . . . . . . . . . . . . . . .182
SP1-7-C  . . . . . . . . . . . . . . . . . . . . . .182
SP1-7L-C  . . . . . . . . . . . . . . . . . . . . .182
SP1-8-C  . . . . . . . . . . . . . . . . . . . . . .182
SP1-8L-C  . . . . . . . . . . . . . . . . . . . . .182
SP2-1/0-L  . . . . . . . . . . . . . . . . . . . . .182
SP2-1/0L-L  . . . . . . . . . . . . . . . . . . . .182
SP2-2/0L-Q  . . . . . . . . . . . . . . . . . . . .182
SP2-2/0-Q  . . . . . . . . . . . . . . . . . . . . .182
SP2-2-C  . . . . . . . . . . . . . . . . . . . . . .182
SP2-2L-C  . . . . . . . . . . . . . . . . . . . . .182
SP2-350-12  . . . . . . . . . . . . . . . . . . . .182
SP2-350L-12  . . . . . . . . . . . . . . . . . . .182
SP2-3-C  . . . . . . . . . . . . . . . . . . . . . .182
SP2-3L-C  . . . . . . . . . . . . . . . . . . . . .182
SP2-4/0L-Q  . . . . . . . . . . . . . . . . . . . .182
SP2-4/0-Q  . . . . . . . . . . . . . . . . . . . . .182
SP2-4-C  . . . . . . . . . . . . . . . . . . . . . .182
SP2-4L-C  . . . . . . . . . . . . . . . . . . . . .182
SP2-500-12  . . . . . . . . . . . . . . . . . . . .182
SP2-500L-12  . . . . . . . . . . . . . . . . . . .182
SP2-7-C  . . . . . . . . . . . . . . . . . . . . . .182
SP2-7L-C  . . . . . . . . . . . . . . . . . . . . .182
SP2-8-C  . . . . . . . . . . . . . . . . . . . . . .182
SP2-8L-C  . . . . . . . . . . . . . . . . . . . . .182
SP688-C  . . . . . . . . . . . . . . . . .

11,67

SRB19BL  . . . . . . . . . . . . . . . . . . . . . .66
SRBM19BL  . . . . . . . . . . . . . . . . . . . . .66
SRBS19BL-X  . . . . . . . . . . . . . . . . . . .66
SRM19CM3 . . . . . . . . . . . . . . . . . . . .143
SRM19CMV3  . . . . . . . . . . . . . . . . . .143
SRM19FM1  . . . . . . . . . . . . . . . . . . . .143
SRM19FM2  . . . . . . . . . . . . . . . . . . . .143
SRM19MK2 . . . . . . . . . . . . . . . . . . . .143
SRM19MPK2  . . . . . . . . . . . . . . . . . .143
SRM23MK2 . . . . . . . . . . . . . . . . . . . .143
STP6X**MBBLL  . . . . . . . . . . . . . . . . .13
STP6X1MBBL  . . . . . . . . . . . . . . . . . . .11
STP6X1MIG  . . . . . . . . . . . . . . . . . . . .69
STP6X2MIG  . . . . . . . . . . . . . . . . . . . .69
STP6X3MIG  . . . . . . . . . . . . . . . . . . . .69
STP6X5MIG  . . . . . . . . . . . . . . . . . . . .69
STPC1MBBL  . . . . . . . . . . . . . . .

9,70

STPC1MBBL . . . . . . . . . . . . . . . . . . . .70
STPC2MBBL . . . . . . . . . . . . . . . . . . . .70
STPC3MBBL . . . . . . . . . . . . . . . . . . . .70
STPC5MBBL . . . . . . . . . . . . . . . . . . . .70
STPCTG10MBBL  . . . . . . . . . . . . . . . .52
STPCTG30MBBL  . . . . . . . . . . . . . . . .52
STPCTG3MBBL  . . . . . . . . . . . . . . . . .52
STPCTG5MBBL  . . . . . . . . . . . . . . . . .52
STPCTG7MBBL  . . . . . . . . . . . . . . . . .52
STPCTG8MBBL  . . . . . . . . . . . . . . . . .52

T

T450CIW   . . . . . . . . . . . . . . . . . . . . .299

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

Panduit-Pannet-html.html
background image

402

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in 

BOLD

.

T45B    . . . . . . . . . . . . . . . . . . . . . . . .263
T45BIW10    . . . . . . . . . . . . . . . . . . . .298
T45BIW10-A  . . . . . . . . . . . . . . . . . .298
T45BIW8   . . . . . . . . . . . . . . . . . . . . .298
T45BIW8-A  . . . . . . . . . . . . . . . . . . .298
T45C    . . . . . . . . . . . . . . . . . . . . . . . .263
T45CCIW-X   . . . . . . . . . . . . . . . . . . .299
T45CIW10   . . . . . . . . . . . . . . . . . . . .298
T45CIW8    . . . . . . . . . . . . . . . . . . . . .298
T45DW    . . . . . . . . . . . . . . . . . . . . . .263
T45DW10   . . . . . . . . . . . . . . . . . . . . .298
T45DW8   . . . . . . . . . . . . . . . . . . . . . .298
T45ECIW   . . . . . . . . . . . . . . . . . . . . .299
T45EEIW   . . . . . . . . . . . . . . . . . . . . .299
T45HDBIW   . . . . . . . . . . . . . . . . . . . .299
T45HEBIW   . . . . . . . . . . . . . . . . . . . .299
T45HEGIW   . . . . . . . . . . . . . . . .299,295
T45ICIW   . . . . . . . . . . . . . . . . . . . . . .299
T45RAIW   . . . . . . . . . . . . . . . . . . . . .299
T45RLDIW   . . . . . . . . . . . . . . . . . . . .299
T45RLDIW   . . . . . . . . . . . . . . . . . . . .299
T45TD   . . . . . . . . . . . . . . . . . . . . . . .299
T45TIW   . . . . . . . . . . . . . . . . . . . . . .299
T45TRI   . . . . . . . . . . . . . . . . . . . . . . .299
T45WC2IW  . . . . . . . . . . . . . . . . . . . .299
T45WCIW  . . . . . . . . . . . . . . . . . . . . .299
T45WR-X   . . . . . . . . . . . . . . . . . . . . .299
T50-C1   . . . . . . . . . . . . . . . . . . . . . . .345
T50F-C   . . . . . . . . . . . . . . . . . . . . . . .345
T50F-C0   . . . . . . . . . . . . . . . . . . . . . .345
T50F-C10   . . . . . . . . . . . . . . . . . . . . .345
T50F-C2   . . . . . . . . . . . . . . . . . . . . . .345
T50F-C2 16  . . . . . . . . . . . . . . . . . . . .345
T50F-C3   . . . . . . . . . . . . . . . . . . . . . .345
T50F-C4   . . . . . . . . . . . . . . . . . . . . . .345
T50F-C5   . . . . . . . . . . . . . . . . . . . . . .345
T50F-C6   . . . . . . . . . . . . . . . . . . . . . .345
T50F-C7   . . . . . . . . . . . . . . . . . . . . . .345
T50F-C8   . . . . . . . . . . . . . . . . . . . . . .345
T50FR-C   . . . . . . . . . . . . . . . . . . . . .345
T50FR-C20   . . . . . . . . . . . . . . . . . . .345
T70    . . . . . . . . . . . . . . . . . . . . . . . . .263
T702BCIW-X    . . . . . . . . . . . . . . . . . .289
T702BIW10    . . . . . . . . . . . . . . . . . . .288
T702BIW8    . . . . . . . . . . . . . . . . . . . .288
T702ECIW    . . . . . . . . . . . . . . . . . . .289
T702EEIW   . . . . . . . . . . . . . . . . . . . .289
T702ICIW    . . . . . . . . . . . . . . . . . . . .289
T702OCIW    . . . . . . . . . . . . . . . . . . .289
T702RAIW    . . . . . . . . . . . . . . . . . . .289
T702TIW    . . . . . . . . . . . . . . . . . . . . .289
T702TRI    . . . . . . . . . . . . . . . . . . . . .289
T702TRIW   . . . . . . . . . . . . . . . . . . . .289
T702TRLIW    . . . . . . . . . . . . . . .285,287
T70B    . . . . . . . . . . . . . . . . . . . .263,281
T70BCIW-X    . . . . . . . . . . . . . . . . . . .286
T70BFI    . . . . . . . . . . . . . . . . . . . . . .287
T70BFIW    . . . . . . . . . . . . . . . . . . . . .287
T70BIW10    . . . . . . . . . . . . . . . . . . . .286
T70BIW8    . . . . . . . . . . . . . . . . . . . . .286
T70C    . . . . . . . . . . . . . . . . . . . .263,281
T70CCIW-X   . . . . . . . . . . . .275,286,289
T70CIW10    . . . . . . . . . . . . . . . .274,288
T70CIW8    . . . . . . . . . . . . . . . . .274,288
T70CIW8    . . . . . . . . . . . . . . . . . . . . .286
T70DB-X    . . . . . . . . . . . . .276,,281,290
T70DW    . . . . . . . . . . . . . . . . . . .263,281
T70DW10    . . . . . . . . . . . . . . . . . . . .286

T70DW8    . . . . . . . . . . . . . . . . . . . . .286
T70EC    . . . . . . . . . . . . . . . . . . . . . . .263
T70ECIW    . . . . . . . . . . . . . . . . . . . .287
T70EEIW   . . . . . . . . . . . . . . . . . . . . .287
T70FSB    . . . . . . . . . . . . . . . . . . . . . .290
T70HB3GFCI-X   . . . . . . . . . . . . . . . .290
T70HB3-X    . . . . . . . . . . . . . . . . . . . .290
T70HB-X    . . . . . . . . . . . . . . . . . . . . .290
T70ICIW    . . . . . . . . . . . . . . . . . . . . .286
T70OCIW    . . . . . . . . . . . . . . . . . . . .287
T70PG   . . . . . . . . . . . . . . . . . . .263, 281
T70RAIW    . . . . . . . . . . . . . . . . . . . .286
T70SDB-X    . . . . . . . . . . . . . . . .259,290
T70S-X    . . . . . . . . . . . . . . . . . . . . . .290
T70TD    . . . . . . . . . . . . . . . . . . . . . . .287
T70TIW    . . . . . . . . . . . . . . . . . . . . . .287
T70TRCIW    . . . . . . . . . . . . . . . . . . .287
T70TRI    . . . . . . . . . . . . . . . . . . . . . .287
T70W2CIW    . . . . . . . . . . . . . . .281,287
T70WC2    . . . . . . . . . . . . . . . . . .263,281
T70WCIW    . . . . . . . . . . . . . . . . . . . .287
T70WM40TRIW    . . . . . . . . . . . . . . .287
T70WR-X    . . . . . . . . . . . . . . . . . . . .290
TAPC2-2/0-X    . . . . . . . . . . . . . . . . . .180
TF3IW-E    . . . . . . . . . . . . . . . . . . . . .317
TF5IW-E    . . . . . . . . . . . . . . . . . . . . .317
TF10IW-X    . . . . . . . . . . . . . . . . . . . .317
TFC3IW-X    . . . . . . . . . . . . . . . . . . . .318
TFC5IW-X    . . . . . . . . . . . . . . . . . . . .318
TFC10IW-X    . . . . . . . . . . . . . . . . . . .318
TFX3IW-X    . . . . . . . . . . . . . . . . . . . .319
TFX5IW-X    . . . . . . . . . . . . . . . . . . . .319
TFX10IW-X    . . . . . . . . . . . . . . . . . . .319
TFXD10IW-X   . . . . . . . . . . . . . . . . . .313
TG70BCIW-X    . . . . . . . . . . . . . . . . .275
TG70HB3GFCI-X    . . . . . . . . . . . . . .276
TG70HB3-X    . . . . . . . . . . . . . . . . . .276
TG70IW10   . . . . . . . . . . . . . . . . . . . .274
TG70IW8   . . . . . . . . . . . . . . . . . . . . .274
TG70WR-X    . . . . . . . . . . . . . . . . . . .276
TGBFI    . . . . . . . . . . . . . . . . . . . . . . .275
TGBFIW    . . . . . . . . . . . . . . . . . . . . .275
TGDW10    . . . . . . . . . . . . . . . . . . . . .274
TGDW8    . . . . . . . . . . . . . . . . . . . . . .274
TGECIW    . . . . . . . . . . . . . . . . . . . . .275
TGEEIW    . . . . . . . . . . . . . . . . . . . . .275
TGFSB    . . . . . . . . . . . . . . . . . . . . . .276
TGICIW    . . . . . . . . . . . . . . . . . . . . . .275
TGOCIW    . . . . . . . . . . . . . . . . . . . . .275
TGRAIW    . . . . . . . . . . . . . . . . . . . . .275
TGSICIW   . . . . . . . . . . . . . . . . . . . . .275
TGSOCIW    . . . . . . . . . . . . . . . . . . . .275
TGTD    . . . . . . . . . . . . . . . . . . . . . . .275
TGTIW    . . . . . . . . . . . . . . . . . . . . . .275
TGTRIW    . . . . . . . . . . . . . . . . . . . . .275
TM1S4-C   . . . . . . . . . . . . . . . . . . . . .337
TM1S6-C   . . . . . . . . . . . . . . . . . . . . .337
TM2S6-C   . . . . . . . . . . . . . . . . . . . . .337
TM2S8-C   . . . . . . . . . . . . . . . . . . . . .337
TM3S10-C   . . . . . . . . . . . . . . . . . . . .337
TM3S25-C   . . . . . . . . . . . . . . . . . . . .337
TM3S8-C   . . . . . . . . . . . . . . . . . . . . .337
TM3S8-C   . . . . . . . . . . . . . . . . . . . . .337
TMEH-S10-C100   . . . . . . . . . . . . . . .337
TMEH-S10-Q0   . . . . . . . . . . . . . . . . .337
TMEH-S25-Q0   . . . . . . . . . . . . . . . . .337
TMEH-S8-Q0   . . . . . . . . . . . . . . . . . .337
TNR . . . . . . . . . . . . . . . . . . . . . . . . . .248

TR1-12-X . . . . . . . . . . . . . . . . . . . . . .214
TR1-58-X . . . . . . . . . . . . . . . . . . . . . .214
TRAKS    . . . . . . . . . . . . . . . . . . . . . .157
TRC18FR-X8  . . . . . . . . . . . . . . .139,214
TRC2BL  . . . . . . . . . . . . . . . . . . . . . .239
TRC2HDBL  . . . . . . . . . . . . . . . . . . . .231
TRC4BL  . . . . . . . . . . . . . . . . . . . . . .239
TREC    . . . . . . . . . . . . . . . . . . . .156,157
TREC24R . . . . . . . . . . . . . . . . . .154,157
TRENB's  . . . . . . . . . . . . . . . . . . . . . . .15
TRENBS1984 . . . . . . . . . . . . . . .156,157
TRENBS2384    . . . . . . . . . . . . .156,157
TRENBSW2384  . . . . . . . . .154,156,157
TRENBW2384    . . . . . . . . . . . . . . . .157
TRFG19  . . . . . . . . . . . . . . . . . . . . . .157
TRFG23  . . . . . . . . . . . . . . . . . . . . . .157
TRGB19    . . . . . . . . . . . . . . . . . .161,162
TRGB191    . . . . . . . . . . . . . . . . . . . .162
TRGB23    . . . . . . . . . . . . . . . . . . . . .162
TRGB231    . . . . . . . . . . . . . . . . .161,162
TRGK672     . . . . . . . . . . . . . . . .161,162
TRGKE696      . . . . . . . . . . . . . .161,172
TRGKJ1024      . . . . . . . . . . . . . .161,162
TRGKJ4120      . . . . . . . . . . . . . .161,162
TRRG236    . . . . . . . . . . . . . . . . . . . .157
TRT19LF    . . . . . . . . . . . . . . . . . . . . .157
TRT23LF    . . . . . . . . . . . . . . . . . . . . .157
TRTA19  . . . . . . . . . . . . . . . . . . . . . . .157
TRTA23  . . . . . . . . . . . . . . . . . . . . . . .157
TRVSM4    . . . . . . . . . . . . . . . . . . . . .157

U

UILS8BW  . . . . . . . . . . . . . . . . . . . . .353
UISW . . . . . . . . . . . . . . . . . . . . . . . . .356
UIT70FH2  . . . . . . . . . . . . . . . . . . . . .263
UIT70FH4  . . . . . . . . . . . . . . . . . . . . .263
UIT70FV4  . . . . . . . . . . . . . . . . . . . . .263
UJBU10MBL  . . . . . . . . . . . . . . . . . . . .52
UJBU15MBL  . . . . . . . . . . . . . . . . . . . .52
UJBU20MBL  . . . . . . . . . . . . . . . . . . . .52
UJBU3MBL  . . . . . . . . . . . . . . . . . . . . .52
UJBU5MBL  . . . . . . . . . . . . . . . . . . . . .52
UJBU7MBL  . . . . . . . . . . . . . . . . . . . . .52
UJLBU10MBL  . . . . . . . . . . . . . . . . . . .52
UJLBU15MBL  . . . . . . . . . . . . . . . . . . .52
UJLBU20MBL  . . . . . . . . . . . . . . . . . . .52
UJLBU3MBL  . . . . . . . . . . . . . . . . . . . .52
UJLBU5MBL  . . . . . . . . . . . . . . . . . . . .52
UJLBU7MBL  . . . . . . . . . . . . . . . . . . . .52
UPBU100  . . . . . . . . . . . . . . . . . . . . . .52
UPBU10M  . . . . . . . . . . . . . . . . . . . . . .51
UPBU20  . . . . . . . . . . . . . . . . . . . . . . .52
UPBU30M  . . . . . . . . . . . . . . . . . . . . . .51
UPBU40M  . . . . . . . . . . . . . . . . . . .51,52
UPBU50  . . . . . . . . . . . . . . . . . . . . . . .52
UPBU5M  . . . . . . . . . . . . . . . . . . . . . . .51
UPBU7M  . . . . . . . . . . . . . . . . . . . . . . .51
UPBU8M  . . . . . . . . . . . . . . . . . . . . . . .51
UPLBU10M  . . . . . . . . . . . . . . . . . . . . .52
UPLBU30M  . . . . . . . . . . . . . . . . . . . . .52
UPLBU40M  . . . . . . . . . . . . . . . . . . . . .52
UPLBU5M  . . . . . . . . . . . . . . . . . . . . . .52
UPLBU7M  . . . . . . . . . . . . . . . . . . . . . .52
UPLBU8M  . . . . . . . . . . . . . . . . . . . . . .52
UTP6X**M . . . . . . . . . . . . . . . . . . . . . .12
UTP6X1.5M . . . . . . . . . . . . . . . . . . . . .68
UTP6X1M  . . . . . . . . . . . . . . . . . . . . . .68
UTP6X2M  . . . . . . . . . . . . . . . . . . . . . .68

Part Number

Page

Number

Part Number

Page

Number

Part Number

Page

Number

Panduit-Pannet-html.html
background image

403

For technical assistance please call 

PANDUIT

customer services. The number can be found on the inside back cover.

UTP6X3M  . . . . . . . . . . . . . . . . . . . . . .68
UTP6X5M  . . . . . . . . . . . . . . . . . . . . . .68
UTPCH1.5M  . . . . . . . . . . . . . . . . . . . .70
UTPCH1M . . . . . . . . . . . . . . . . . . . . 8,70
UTPCH2.5M  . . . . . . . . . . . . . . . . . . . .70
UTPCH2M . . . . . . . . . . . . . . . . . . . . . .70
UTPCH3M . . . . . . . . . . . . . . . . . . . . . .70
UTPCH5M . . . . . . . . . . . . . . . . . . . . . .70
UTPCH8  . . . . . . . . . . . . . . . . . . . . . . .64
UTPCH812PP25  . . . . . . . . . . . . . . . . .65
UTPCH8L25  . . . . . . . . . . . . . . . . . . . .65
UTPCH8LR25  . . . . . . . . . . . . . . . . . . .65
UTPCH8R25  . . . . . . . . . . . . . . . . . . . .65
UTPCH8SL25  . . . . . . . . . . . . . . . . . . .65
UTPCH8SR25 . . . . . . . . . . . . . . . . . . .65
UTPSP1M  . . . . . . . . . . . . . . . . . . . . . .68
UTPSP2M  . . . . . . . . . . . . . . . . . . . . . .68
UTPSP3M  . . . . . . . . . . . . . . . . . . . . . .68
UTPSP4M  . . . . . . . . . . . . . . . . . . . . . .68
UTPSP5M  . . . . . . . . . . . . . . . . . . . . . .68

V

VP24382TV25 . . . . . . . . . . . . . . . . . . .66
VP50384KBL . . . . . . . . . . . . . . . . . . . .66
VWS106-C  . . . . . . . . . . . . . . . . . . . .118
VWSDC-C  . . . . . . . . . . . . . . . . . . . . .118
VWSDC-C  . . . . . . . . . . . . . . . . . . . . . .66

W

WB89D  . . . . . . . . . . . . . . . . . . . . . . . .61
WBH1  . . . . . . . . . . . . . . . . . . . . . . . .144
WBH2  . . . . . . . . . . . . . . . . . . . . . . . .144
WBH2E  . . . . . . . . . . . . . . . . . . . . . . .144
WBH3  . . . . . . . . . . . . . . . . . . . . . . . .144
WBH4  . . . . . . . . . . . . . . . . . . . . . . . .144
WBH4E  . . . . . . . . . . . . . . . . . . . . . . .144
WBH6E  . . . . . . . . . . . . . . . . . . . . . . .144
WBS6-Q  . . . . . . . . . . . . . . . . . . . . . .340
WBS6-Q60   . . . . . . . . . . . . . . . . . . . .340
WCM35BIW  . . . . . . . . . . . . . . . . . . .263
WCM35BIW8  . . . . . . . . . . . . . . . . . .266
WCM35CCIW  . . . . . . . . . . . . . . . . . .267
WCM35CIW  . . . . . . . . . . . . . . . . . . .267
WCM35CIW8  . . . . . . . . . . . . . . . . . .266
WCM35DBFIW  . . . . . . . . . . . . . . . . .267
WCM35DW8  . . . . . . . . . . . . . . . . . . .266
WCM35ECIW  . . . . . . . . . . . . . .263, 267
WCM35IW8 . . . . . . . . . . . . . . . . . . . .266
WCM35OCIW  . . . . . . . . . . . . . . . . . .267
WCM35TI  . . . . . . . . . . . . . . . . . . . . .267
WCM35TIW . . . . . . . . . . . . . . . . . . . .267
WCM35TR10IW  . . . . . . . . . . . . . . . .267
WCM35TR70IW  . . . . . . . . . . . . . . . .267
WMCPEBL  . . . . . . . . . . . . . . . . . . . . .48
WMCPEPPBL  . . . . . . . . . . . . . . . . . . .48
WMCPESGBL . . . . . . . . . . . . . . . . . . .48
WMP1E  . . . . . . . . . . . . . . . . . . . . . . .148
WMPF1E . . . . . . . . . . . . . . . . . . . . . .148
WMPFSE  . . . . . . . . . . . . . . . . . . . .8,148
WMPH2E . . . . . . . . . . . . . . . . . 8,9,10,11
WMPHF2E  . . . . . . . . . . . .8,9,10,11,148
WMPLFSE  . . . . . . . . . . . . . . . . . . . .148
WMPLSE . . . . . . . . . . . . . . . . . . . . . .148
WMPSE  . . . . . . . . . . . . . . .8,9,10,11,148
WMPV20  . . . . . . . . . . . . . . . . . . . . . .145
WMPV3X5 . . . . . . . . . . . . . . . . . . . . .145
WMPV45  . . . . . . . . . . . . . . . . . .141,145
WMPV50  . . . . . . . . . . . . . . . . . . . . . .145

WMPV6X8 . . . . . . . . . . . . . . . . . . . . .145
WMPVCB  . . . . . . . . . . . . . . . . . . . . .141
WMPVF20 . . . . . . . . . . . . . . . . . . . . .145
WMPVF3X5  . . . . . . . . . . . . . . . . . . .145
WMPVF45 . . . . . . . . . . . . . . . . . . . . .145
WMPVF6X8  . . . . . . . . . . . . . . . .141,145
WMPVFM45 . . . . . . . . . . . . . . . .134,145
WMPVFMHC45 . . . . . . . . . . . . . . . . .145
WMPVHC45  . . . . . . . . . . . . . . . . . . .145
WMPVHCF45  . . . . . . . . . . . . . . . . . .145
WMSRC1  . . . . . . . . . . . . . . . . . . . . .151
WMSRC2  . . . . . . . . . . . . . . . . . . . . .151
WPT-8  . . . . . . . . . . . . . . . . . . . . . . . . .67
WR2-C  . . . . . . . . . . . . . . . . . . . . . . .245
WR3-C  . . . . . . . . . . . . . . . . . . . . . . .245
WR4-C  . . . . . . . . . . . . . . . . . . . . . . .245
WR5-C  . . . . . . . . . . . . . . . . . . . . . . .245

Part Number

Page

Number

Panduit-Pannet-html.html
background image

PANDUIT Europe Ltd.

London, UK

cs-emea@panduit.com

Phone: 44 20 8601 7200

PANDUIT Australia Pty. Ltd.

Victoria, Australia

cs-aus@panduit.com

Phone: 61 3 9794 9020

PANDUIT Singapore Pte. Ltd.

Republic of Singapore

cs-ap@panduit.com

Phone: 65 6379 6700

PANDUIT Japan

Tokyo, Japan

cs-japan@panduit.com

Phone: 81 3 3767 7011

PANDUIT Latin America

Jalisco, Mexico

cs-la@panduit.com

Phone: 11 52 33 3777 6000

PANDUIT Canada

Markham, Ontario

cs-cdn@panduit.com

Phone: 800 777 3300

PANDUIT

Corp.

Tinley Park, Illinois 1 60477 3091

For more information

Visit us at www.panduit.com/emea

Contact Customer Service by email: cs-emea@panduit.com

or by phone: +44 (0) 20 8601 7219

© 2006 

PANDUIT Corp.

ALL RIGHTS RESERVED

Printed in the EU

 

W O R L D W I D E   H E A D Q U A R T E R S

cs-emea@panduit.com 
or by phone +44(0)208 7601 7219

www.panduit.com/emea