background image

Interface Module type (European style, American style, horn terminals)

  

.

  

.

  

.

Modular structure, easy to maintain and replace   

Plug structure easy to install , flexible and convenient

Can be installed in 35mm standard rail

  

    

.

  

    

.

  

.

Compact output modules can be used in combination with 

different front adapter       

Plug type can greatly improve the replacement efficiency 

of relay , save maintenance costs   

Can be installed in 35mm standard rail

DM72 - DBK -   51  -   50   - YY - 00AH

Represents general specification

Represents the note of specific function 

Represents the input number 

Represents the output number  

Represents type of input terminal blocks  

Represents the type of the base

DM7 2 - RMM - 0 8 - PN - 1 - YY - 00 AH

Represents the output mode of relay module

Represents the signal input mode

Represents the quantity of relay 

Represents the specifications of the relay modular

Represents the type of the base 

Represents general specification

Represents the note of specific function 

Relay Module type (European style, American style, horn terminals)   

Y

1

3

PCB

4

5

1

1

2

1

1

3

2

4

2

2

PN

P

N

MT

FC

SI

OM

(

1-XXP

)

RMM

RMUS

RMS

RME

RM

F

DM

45 50 72 100 108 

PCB

I

DBK

D-SUB

DBJ

D-SUB

DM 

45 50 72 100 108 

PCB

Represents the note of specific function 

Y

I

Represents the note of specific function 

Y

L

LED

(

1-XXP

)

Y

1

3

PCB

4

PCB

5

(

1-XXP

)

(1 means pluggable terminal blocks,3 means PCB screwless terminal blocks,4 means PCB screw terminal blocks,5 means barrier terminal blocks)

(PN means high low potential input way, p means high potential input, N means low potential input, MT means Mitsubishi system, FC means Fanuc system, SI means Siemens system, OM means Omron system )

(I means horn socket)

(1 means 1 NO,2 means 1NC 1 NO,3 means 2 NO,4 means 2 NO 2 NC)

(

1-XXP

)

(RMM  microminiature relay RMUS  subminiature relay, RMS midget relay, RME solid-state relay, RM normal relay, F means fuse)

(

DM means module, 45 50 72 100 108 means PCB width.

)

(L means LED lighting)

(1 means pluggable terminal blocks,3 means PCB screwless terminal blocks,4 means PCB screw terminal blocks,5 means barrier terminal blocks)

(

1-XXP

)

(

1-XXP

)

(I means horn socket ,DBK means D-SUB male connector, DBJ means D-SUB female connector)

(

DM means module, 45 50 72 100 108 means PCB width.

)

NC  2

L/W/H

Rated Voltage/Current

NO  2

130/87/64

24V  1A

DM72-RM-08-PN-4-44-00AH

NC  2

L/W/H

Rated Voltage/Current

NO  2

326.5/87/64

24V  2A

DM72-RM-16-MT-4-4C-00AH

DM72-RM-18-FC-4-4C-00AH

L/W/H

NO  2

292/87/64

24V  2A

Rated Voltage/Current

NC  2

DM72-RM-22-MT-4-11-00AH

NC  2

L/W/H

Rated Voltage/Current

NO  2

270/87/64

24V  2A

K1_1

K1_2

K3_1

K5_1

K5_2

K2_2

K7

X1

X2

X3

X4

X5

1

2

3

13 14

X6

231 233 235 237 239 241 243 245 247 249

YA1

100 100 101 101 102 102 103 103

301

329

402 403 405 409 411 413 505 605

331 333 335 337 339 341 401

309 313 314 315 317 319 325

22P

8P

14P

YA8

NC  1

L/W/H

NO 1

78.5/87/64

Rated Voltage/Current

24V   0.5A

DM72-RM-04-P-2-44-00AH

+

-

12

NC

14

NO

P

O

W
E

R

K1

X2

-

1

2

4

+

K2

K4

X1

X3

11

C

22

NC

24

NO

21

C

42

NC

44

NO

41

C

P

O

W
E

R

K1

X2

-

1

2

+

12

NC

K2

X1

X3

14

NO

11

C

22

NC

24

NO

21

C

NC  1

L/W/H

NO  1

45/87/64

Rated Voltage/Current

24V   0.2A

DM72-RM-02-P-2-44-00AH

DM72-RM-04-P-4-44-00AH

L/W/H

NO  2

90/87/64

24V  0.5A

Rated Voltage/Current

NC  2

P

O

W
E

R

K1

11
C

X2

-

1

2

4

+

K2

K4

X1

X3

12

NC

14
NO

111

C

21
C

122
NC

124

NO

22
NC

24

NO

121
 C

41

C

142
NC

144

NO

42

NC

44
NO

141

 C

112
NC

114
NO

DM72-RM-01-PN-4-44-00AH

NC  2

L/W/H

NO  2

22.5/77.5/64

Rated Voltage/Current

24V   0.1A

POWER

C

NO

NC

NO

X1

NC

+

-

X2

C

K1

NC  1

L/W/H

Rated Voltage/Current

24V   0.1A

22.5/77.5/64

NO  1

DM72-RM-01-PN-2-44-00AH

C

N0

K1

X2

-

+

NC

X1

POWER

RELAY MODULE

   

   

       

   

   

       

.

   

       

.

   

.

Compact output modules can be used in combination 

with different front adapter       

Plug type can greatly improve the replacement 

efficiency of relay , save maintenance costs   

Can be installed in 35mm standard rail

X1

X2

X3

KA1

1

13

14

KA2

2

KA16

16

23

24

163

164

+

+

+

DM72-RMUS-16-N-1-44-00AH

L/W/H

NO  1

90/87/64

24V  2A

Rated Voltage/Current

NC  -

NC  2

L/W/H

Rated Voltage/Current

NO  2

45/87/64

24V  0.2A

DM72-RM-02-P-4-44-00AH

X3

X1

K2

+

2

1

-

X2

112

NC

122

NC

12

NC

22

NC

11

C

21

C

114

NO

124

NO

14

NO

24

NO

111

C

121

C

K1

P

O

W
E

R

8

1

2

8

1

4

8

2

2

8

2

4

8

2

1

8

1

1

2

1

2

2

1

4

2

2

2

2

2

4

2

2

1

2

1

1

1

1

2

1

1

4

1

2

2

1

2

4

1

2

1

1

1

1

X1

8

KA8

2

KA2

1

KA1

+

+

-

-

-

+

~
~

-

+

~
~

-

+

~
~

X2

E24

K18 0V K17

A01

(E24)

B25

A25

(E24)

B24

A24

B23

B16

A23

A16

B14

B02

A14

A02

(N24)

(0V)

B01

A01

1

8

1

1

1

8

1

4

1

8

1

2

1

8

2

4

1

8

2

1

1

8

2

2

B01 A02

KA18

B02 A03

A13 B13 A14 B14

XT1

XT3

XT2

KA16

1

7

1

1

1

7

1

4

1

7

1

2

1

7

2

4

1

7

2

1

1

7

2

2

KA1

KA17

0V

1

1

1

1

1

4

1

1

2

1

2

4

1

2

1

1

2

2

1

4

1

1

1

4

1

4

1

4

1

2

1

4

2

4

1

4

2

1

1

4

2

2

XT1

A04

B05B04

B06

(24V)

(0V)

B02

A02

KA16

0V

KA15

0V

1

5

1

1

1

5

1

4

1

5

1

2

1

5

2

4

1

5

2

1

1

5

2

2

XT3

XT2

A06

B06

B05

B04

A04

B20

A20

B01

A01

KA15

JP2
JP4

JP1
JP3

A19 A20

0V24V

1

6

1

1

1

6

1

4

1

6

1

2

1

6

2

4

1

6

2

1

1

6

2

2

0V

XT4

0V

KA1

KA16

1

2

2

1

2

1

1

2

4

1

1

2

1

1

4

1

1

1

KA14

1

4

1

1

1

4

1

4

1

4

1

2

1

4

2

4

1

4

2

1

1

4

2

2

11
C

12

NC

14
NO

111

C

112
NC

114
NO

21
C

12

NC

14
NO

121

C

122
NC

124
NO

161

C

162
NC

164
NO

321

C

322
NC

324
NO

DM72-RM-08-P-4-44-00AH

NC  2

L/W/H

Rated Voltage/Current

NO  2

169/87.5/64

24V   1A

NC

112

NO

114

P

O

W
E

R

K1

C

11

X2

-

1

2

8

+

K2

K8

X1

X3

NC

12

NO

14

C

111

C

21

NC

122

NO

124

NC

22

NO

24

 C

121

C

81

NC

182

NO

184

NC

82

NO

84

 C

181

DM72-RM-16-P-1-44-00AH

NC  -

L/W/H

NO  1

186/87/48

Rated Voltage/Current

24V   2A

+

-

NO

164

NO

14

P

O

W
E

R

K1

X2

-

1

2

16

+

K2

K16

X1

X3

C

11

NO

24

 C

21

 C

161

DM72-RM-16-P-1-4I-00AH

NC  -

L/W/H

NO  1

186/87/48

Rated Voltage/ Current

24V    2A

NC

164

NC

14

20

18

19

17

P

O

W
E

R

K1

X2

-

1

2

16

+

K2

K16

X1

X3

C

11

NC

24

 C

21

 C

161

1

2

3

4

17

18

19

20

X1

NO  1

134.5/87/64

24V   1A

NC  1

L/W/H

Rated Voltage/Current

DM72-RM-08-P-2-44-00AH

+

-

NC

12

NO

14

P

O

W
E

R

K1

X2

-

1

2

8

+

K2

K8

X1

X3

C

11

NC

22

NO

24

 C

21

NC

82

NO

84

 C

81

NC  1

L/W/H

NO  1

Rated Voltage/Current

24V   1.5A

270/87/64

DM72-RM-16-P-2-44-00AH

+

-

NC

12

NO

14

P

O

W
E

R

K1

X2

-

1

2

16

+

K2

K16

X1

X3

C

11

NC

22

NO

24

 C

21

NC

162

NO

164

 C

161

NC  1

L/W/H

NO  1

Rated Voltage/Current

24V   1A

135/8764

DM72-RM-08-P-2-4I-00AH

13

11

9

10

12

14

112

NC

114

NO

P

O

W
E

R

K1

X2

-

1

2

8

+

K2

K8

X1

X3

111

C

122

NC

124

NO

121

C

182

NC

184

NO

181

C

1

2

3

4

5

6

7

8

9

10

11

12

13

14

X1

DM72-RM-16-P-2-4I-00AH

L/W/H

Rated Voltage/Current

270/87/64

24V    2A

NC  1

NO  1

1

2

3

4

5

6

7

8

19

20

X1

+

-

NC

172

NO

174

P

O

W
E

R

K1

X2

-

3

1 2

19

20

4

18

+

K2

K16

X1

X3

C

171

NC

182

NO

184

 C

181

NC

322

NO

324

 C

321

NC  2

L/W/H

NO  2

326.5/87/64

Rated Voltage/Current

24V   2A

DM72-RM-16-P-4-4I-00AH

172

NC

182

NC

322

NC

12

NC

22

NC

162

NC

11

C

21

C

161

C

174

NO

184

NO

324

NO

14

NO

24

NO

164

NO

171

C

181

C

321

C

20

- +

1

2

-

+

X3

X1

X2

19

X1

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

18

K16

4

K2

3

K1

POWER

DM72-RM-08-P-4-4I-00AH

NC  2

L/W/H

Rated Voltage/Current

NO  2

168.5/87/64

24V   2A

1

2

3

4

5

6

7

8

15

16

X1

X2

K16

+

16

2

1

-

X1

X3

P

O

W
E

R

K1

DM108-RM-32-P-1-4I-00AH

L/W/H

224/122.2/48

NC  -

Rated Voltage/Current

NO  1

24V  2.5A

 321

NC

39

- +

38 40

-

+

P

O

W

E

R

K1

1

 12

NO

11

C

36

35

34

33

37

 322

NO

21

C

 22

NO

32

K32

2

K2

X3

X1

X2

X1

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

DM72-RMS-08-P-1-4I-00AH

NC  -

L/W/H

NO  1

90/87/51

Rated Voltage/Current

24V  1A

14
NO

4

10

11
C

24
NO

21
C

84
NO

81
NC

K2

X2

K1

X1

K8

20

1 2

19

P

O

W
E

R

X3

3

-

+

- +

X1

1

2

3

4

5

6

7

8

9

10

19

20

DM72-RMS-08-P-1-44-00AH

NC  -

L/W/H

NO  1

90/87/51

Rated Voltage/Current

24V    1A

+

-

P

O

W
E

R

14
NO

1

2

8

11
C

24
NO

21
C

84
NO

81
NC

K2

X2

K1

X1

K8

X3

Brief Introduction

Founded in 1990, DEGSON Electronics Co., Ltd. is one of the largest manufactures of terminal blocks and 

industrial electrical connection products in Asia. As a High-tech enterprise, DEGSON owns the first UL and

VDE

  

authorized

 

laboratory

 

in

 

Asia.

 

DEGSON

 

products

 

have

 

been

 

approved

 

by                                           

The company has been granted ISO9001 , ISO14001 and ISO80079-34 management system certificates.

DEGSON products are very popular in China, 

 

Germany, UK,

 

 

Italy,

 

Spain,

 

Poland, 

 

Russia,  India,  Turkey, 

 

Brazil, 

 

USA, 

 

Japan, 

 

Korea, 

 

South 

 

Africa , etc.,totally

 

more than

 

70

 

countries

 

and

 

areas.

 

DEGSON

 

provide

 

excellent

 

products

 

and

 

service

 

for

 

the

 

customers

 

all

 

over

 

the

 

world,

 

especially

 

in

 

Industrial

 

Automation, 

Instrument,

  

Elevator,

  

Electric

 

Power, Rail

 

Transport,

 

New

 

Energy,

 

Lighting,

 

Telecommunication,

 

Power 

Supply, Security, Ship-building and so on.

DEGSON fulfill the sales network all

 

over

 

the

 

world

 

and

 

set

 

up

 

marketing

 

centers

 

in Germany

 

and

 

Shanghai, 

China.  Pragmatic,  Sincerity,  Responsibility,  Innovation,  Harmonious,  Development,

  

Rule

  

and

  

Win-win.

 

In accordance

 

with

 

these

 

spirits

 

of

 

enterprise

 

for

 

26

 

years,

 

 DEGSON  will  keep  providing  more  speedy, 

comprehensive and professional local service to our customer.  

   

DEGSON 1990

UL

  

VDE

 

ISO9001

ISO14001

ISO80079-34

DEGSON 

   

 

70

DEGSON 

   

     

 

 

26

 

DEGSON

 

       

RELAY MODULE-CE-html.html
background image

6

1 2

7

3

8

5

4

9

X1

X2

02 03 04 05

06 07 08 09

X1

1

2

3

4

5

6

7

8

9

01

DM45-DBK-10-9-4Y-00AH

Rated Voltage

L/W/H

125V    DC

Rated Current

2.5A

54/45/42

1

2

X1

X2

4

6

8

7

5

3

N

1

2

3

4

5

6

6

7

N-1

N

N-3

N-2

N-1

N-3

N-2

DM45-I-50-50-4Y-00AH

Rated Voltage

L/W/H

60V    DC

Rated Current

1A

54/45/50

1

2

X1

X2

4

6

8

7

5

3

N

1

2

3

4

5

6

7

8

N-1

N

N-3

N-2

N-1

N-3

N-2

60V    DC

54/45/50

1A

Rated Voltage

L/W/H

Rated Current

DM45-I-12-10-3Y-00AH

01

01

X1

X2

02

02

03

03

04

04

05

05

06

06

07

07

08

08

09

09

10

10

11

11

12

12

13

13

14

14

15

15

16

16

17

17

18

18

19

19

20

20

Rated Voltage

L/W/H

24V    DC

110/57/43

Rated Current

1A

DM50-I-20-20-5Y-00AH

X1

X2

X3

01

X1

02 03 04 05 06 07 08 09 10

18 19 20 21 22 23 24 25 26 27 28

11 12 13 14 15 16 17

29 30 31 32 33 34

21 22 23 24 25 26 27

28 29 30 31 32 33 34

11 12 13 14 15 16 17 18 19 20
01 02 03 04 05 06 07 08 09 10

21 22 23 24 25 26 27

28 29 30 31 32 33 34

11 12 13 14 15 16 17 18 19 20

01 02 03 04 05 06 07 08 09 10

Rated Voltage

L/W/H

24V    DC

110/57/42

Rated Current

1A

DM50-I-34-34-5Y-00AH

A2

A1

A3

A4

A5

A6

A7

A8

B2

B1

B3

B4

B5

B6

B7

B8

X1

CH1-

X2

CH2- CH3- CH4- CH5- CH6- CH7- CH8-

CH1+ CH2+ CH3+ CH4+ CH5+ CH6+ CH7+ CH8+

Rated Voltage

L/W/H

60V    DC

45/90/68

Rated Current

1A

DM72 -I-16-16-4Y-00AH

DM50-I-26-26-4Y-00AH

Rated Voltage

L/W/H

24V   DC

110/57/43

Rated Current

1A

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

26

25

24

23

22

19 20 21

18

17

14 1516

13

12

11

10

9

6 7 8

13

12

11

5

4

3

2

1

26

25

24

18

17

16

15

14

1

X1

5

4

1 2 3

X2

X2

X1

13

12

11

5

4

3

2

1

26

25

24

18

17

16

15

14

DM50-I-10-10-4Y-00AH

Rated Voltage

L/W/H

24V    DC

Rated Current

1A

65/57/42.5

1

6

0V

2

7

R00 R01

3

8

R02 R03

4

9

R04 R05

5

R06 R07

X2

X1

10

24V

X1

X2

1

6

1

2

7

3

8

5

4

9

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

X1

DM50-DBK-10-9-4Y-00AH

Rated Voltage

L/W/H

24V    DC

Rated Current

1A

66/57/30

X1

X2

14

1

1

14 15 16 17 18 19 20 21 22 23 24 25

X1

2

3

4

5

6

7

8

9 10 11 12 13

15 16 17 18 19 20 21 22 23 24 25

2 3 4 5 6

8 9 10 11 12 13

7

14

1

2

3

4

5

6

7

8

9 10 11 12 13

15 16 17 18 19 20 21 22 23 24 25

DM50-DBK-26-25-4Y-00AH

Rated Voltage

L/W/H

Rated Current

1A

110/57/42.5

24V    DC

50

49

48

6

5

4

3

2

X2

1

50

49

48

6

5

4

3

2

X1

1

DM72-DBJ-51-50-4Y-00AH

L/W/H

L/W/H

/

101/87/63

56/87/63

/

DM72-DBK-21-20-4Y-00AH

L/W/H

L/W/H

L/W/H

89.5/87/51

79/87/51

112/87/51

1

X1

2

3

4

5

6

48 49 50

1

X2

2

3

4

5

6

48 49 50

DM72-RMS-16-P-1-4I-00AH

NC  -

L/W/H

NO  1

180/87/51

24V   2A

Rated Voltage/Current

P

O

W
E

R

K1

 12NO

 22NO

 162NO

 11C

 12C

 116C

X3

2

1

19

20

K16

K2

+

+

--

16

4

3

-

X1

X2

X1

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

DM49-RM-8-P-1-44-00AH

NC  -

L/W/H

Rated Voltage/Current

24V   1A

134/49/48

NO  1

NO

84

NO

14

P

O

W
E

R

K1

X2

-

1

2

8

+

K2

K8

X1

X3

C

11

NO

24

 C

21

 C

81

DM72-RM-16-P-4-44-00AH

NC  2

L/W/H

NO  2

Rated Voltage/Current

24V  1.5A

326.5/87/64

P

O

W
E

R

K1

X2

-

3

4

18

+

K2

K16

X1

X3

DM108-RM-32-P-2-4I-00AH

L/W/H

NO  1

303/122.2/64

24V  2.5A

Rated Voltage/Current

NC  1

39

- +

38 40

-

+

P

O

W

E

R

K1

1

NC

COM

36

35

34

33

NO

COM

NC

NO COM

NC

NO COM

NC

32

K32

37

5

K3

3

K2

X3

X1

X2

NO

X1

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

DM108-I-16-16-4F-00AH

Rated Voltage

L/W/H

24V    DC

Rated Current

1A

61/126/71

8+

8-

SH

7+

7-

SH

6+

6-

SH

5+

5-

SH

4+

4-

3+

3-

2+

2-

SH

SH

SH

SH

1+

1-

X2

15

16

13

14

11

12

9

10

3

5

7

8

6

4

X1

2

1

DM108-RMS-16-P-2-44-00AH

NC1

L/W/H

NO  1

161.5/122/62.2

Rated Voltage/Current

24V  2A

X2

16C

K16

 15NC

 16NC

 15NO

 16NO

15C

K15

2NC 2NO 2C

K2

1NC1NO

+

+

--

16

15

2

1

-

X1

X3

1C

K1

P

O

W
E

R

NC  -

L/W/H

NO  1

123.5/90/87

Rated Voltage/Current

24V  1A

DM72-RME-08-P-1-44-00AH

1113101214

X2

TB1

2

2

24 23

8

8

13

14

1

1

84 83

0V24V

X1

TB2

TB8

9

1

2

8

X2

TB1

1

1

1

KA2

KA8

1

1

4

1

1

2

1

4

1

2

1

1

1

2

1

1

2

4

1

2

2

2

4

2

2

2

1

1

8

1

1

8

4

1

8

2

8

4

8

2

8

1

TB2

0V

X1

TB8

0V

KA1

DM72-RMM-08-P-4-44-00AH

NC  2

L/W/H

NO  2

Rated Voltage/Current

24V  1A

168.8/77/59

35

37

36

35

20 21

36

18

37

19

X1

4

3

2

1

37

36

4

3

2

3

2

1

1

X2

X1

DM45-DBK-38-37-3Y-00AH

Rated Voltage

L/W/H

125V    DC

157/45/45

Rated Current

2.5A

/

L/W/H

/

/

76/74/52

/

DM72-I-16-20-1Y-00AH

X4

X3

X2

20#

19#

2#

1#

F

E

D

C

B

A

8

9

7

6

5

4

3

2

S

1

0

V

N

C

2

4

V

0

1

+

8

9

A

B

C

D

E

F

-

0

1

2

3

4

5

6

7

X1

1F

1E

1D

1C

2#

1#

14#

13#

CN4

2#

1#

17

13

16

12

15

11

14

10

14#

13#

CN5

2#

1#

1B

1A

19

18

14#

13#

CN3

2#

1#

F

B

E

A

D

9

C

8

14#

13#

39#

40#

CN2

2#

1#

-

+

7

3

6

2

5

1

4

0

F

E

D

C

B

A

9

8

7

6

5

4

3

2

1

0

1F

1E

1D

1C

1B

1A

19

18

17

16

15

14

13

12

11

10

X1

/

L/W/H

/

/

90/87/52

/

DM72-I-40-40-1I-00AH

Rated Voltage

L/W/H

Rated Current

24V   DC

65/57/43

10A

DM50-I-8-10-1Y-00AH

8

7

6

910

3

2

1

45

X1

N

10

5

9

4

8

3

7

07

06

05

04

03

02

01

00

P

1

X1

2

6

172

NC

182

NC

322

NC

11

C

21

C

161

C

171

C

181

C

321

C

174

NO

184

NO

324

NO

12

NC

22

NC

162

NC

14

NO

24

NO

164

NO

INTERFACE MODULE

  

  

  

  Modular structure, easy to maintain and  replace. 

  Plug structure easy to install ,  flexible and 

    

 

convenient.

  Can be installed in 35mm standard  rail.

DM72-RMUS-32-P-1-4I-00AH

NC  -

L/W/H

NO  1

Rated Voltage/Current

202/90/58

24V   2.5A

X1

1

2

3

4

5

6

45

46

3

14

13

KA8

10

84

83

X2

B0+ B0-

1,2 11,12

KA9

15

94

93

KA32

46

324

323

X2

B1+ B1-

13,14 23,24

X1

X3

X4

KA1

DM50-RMUS-08-P-1-4I-00AH

NC  -

L/W/H

Rated Voltage/Current

NO  1

65/57/43

24V   1A

KA6

KA5

KA7

KA3

KA2

KA1

KA4

KA8

2

1

+24V

0

5

6

7

0V

3

3

7

2

8

9

5

10

4

4

6

1

X2

X1

0V

7

6

5

4

3

2

1

X1

+24V 0

10

9

8

6 7

5

4

3

X2

1 2

1

11

14

KA2

2

KA8

8

9

11

1310

12

14

X2

X3

12

21

2422

81

0V24V

X1

8482

KA1

DM72-RM-08-P-2-44-00AH

NO  1

135/77/59

24V    1A

NC  1

L/W/H

Rated Voltage/Current

DM72-RM-08-P-1-4I-00AH

NC  -

L/W/H

NO  1

Rated Voltage/Current

24V   1A

56/90/58

X2

1

14

13

KA2

2

24

23

KA8

8

84

83

9

11

13

10

12

14

0V24V

X1

X2

X3

KA1

1

2

3

4

5

6

13

14

DM50-RMUS-16-P-1-4I-00AH

NC  -

L/W/H

Rated Voltage/Current

NO  1

110/54/43

24V   1A

C13

C12

24V

C15

C14

C11

C10

C9

C8

C7

C6

C5

C4

C3

C2

C1

C0

13

12

0V

15

14

11

10

9

8

7

6

5

4

3

2

1

X2

0

15

14

111213

20

19

161718

X1

5

4

1 2 3

10

9

6 7 8

0V

24V

C2

X1

C13

C11

KA15

KA12

KA9

KA10

KA11

KA14

KA16

KA13

KA7

KA4

KA1

KA2

KA3

KA6

KA8

KA5

C15

C14

C12

C10

C7

C8

C9

C6

C5

C4

C3

C0

C1

20

19

10

9

11

15

18

11

14

13

12

10

7

8

9

13

17

16

15

14

8

12

6

5

4

3

0

1

2

3

7

6

5

4

1

2

X2

DM50-RME-08-N-1-44-00AH

NC  -

L/W/H

NO  1

Rated Voltage/Current

24V   2A

110/54/41.6

DM50-RME-04-P-1-44-00AH

NC  -

L/W/H

NO  1

Rated Voltage/Current

24V   1A

65.5/57/30.5

X2

X1

C3 3

0V

3

2

1

X1

0V

0

2

C2

1

C1

X2

C0 0

0

0V

3

3

C3

2

2

C2

1

1

C1

0V

0

C0

DM72-I-50-50-4Y-00AH

L/W/H

L/W/H

L/W/H

56/87/51

44.5/87/51

67/87/51

63

61

59

64

62

60

63

61

59

10

8

6

4

2

9

7

5

3

1

1

64

62

60

10

8

6

4

2

X2

9

7

5

3

X1

1

DM72-DBJ-26-26-4Y-00AH

L/W/H

L/W/H

L/W/H

57/87/51

45/87/51

79.5/87/51

1

X1

2

3

4

5

6

48 49 50

1

X2

2

3

4

5

6

48 49 50

DM108-DBK-38-37-4Y-00AH

L/W/H

L/W/H

57/87/51

45/87/51

L/W/H

79.5/87/51

1

X1

2

3

4

5

6

48 49 50

1

X2

2

3

4

5

6

48 49 50

+24V

7

6

5

4

3

2

1

+24V

0

X1

7

7

C7

6

6

C6

X2

X1

0

+24V

2

2

C2

1

1

C1

+24V

0

C0

DM50-RMUS-08-P-1-44-00AH

NC  -

L/W/H

Rated Voltage/Current

24V   1A

65.5/57/30.5

NO  1

KA5

KA7

X2

KA6

KA3

KA2

KA1

KA4

C0

KA4

2

1

X1 0V

0

4

5

6

7

3

2

1

0

3

4

5

6

7

C1

0

0V

X1

1 2 3 4 5 6 7

0

C0

X2

1 2 3 C1 5 6 7

THR &SMD Terminal Blocks

Din Rail Terminal Blocks

American Terminal Blocks

OEM/ODM

Transformer Terminal Blocks 

Din Rail Terminal Blocks

American Terminal Blocks

European  Terminal Blocks

Euro Terminal Block

ISO9001 ISO14001

Keep Connecting

TRANSFORMER 

TERMINAL BLOCKS 

      IC-14-02
Edition:T78

EU 15-CE01

1585

Add: No.1585. Xiaolin Road. Cixi.

        Ningbo China          

P.C.: 315321

Te l :  +86-574-63504333  

Fax: +86-574-63512345 

E-mail: sale@degson.com

www.degson.com

ISO9001 ISO14001 ISO80079-34

RM 16-CE01

RELAY  MODULE