DATA SHEET
Ametherm, Inc
. 3111 N. Deer Run Road #4 Carson City, NV 89701
Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670
www.ametherm.com
Part Number: SL08 33001-P
Ordering Different Lead Types:
For example: to order an inside kinked lead use part number SL08 33001-P
-A
Electrical
Specifications:
Mechanical
Specifications:
CSA File #: CA 118061
Revision Date: March 19, 2003
Inside Kinked Leads
Use
-A
after Ametherm’s part #
Outside Kinked Leads
Not Available
Resistance @ 25°C
33.0
Ω
±
20%
Max Steady State Current Up to 65°C
1.3 A
Max Recommended Energy Rating (Joules)
8.0 J
Actual Failure Point of Instantaneous Energy (Joules)
16.0 J
Resistance @ 100% of Max Current
0.750
Ω
Resistance @ 50% of Max Current
1.50
Ω
Body Temperature @ 100% Current Rating
112 °C
Dissipation Constant
9.30mW/°C
Thermal Time Constant
29 seconds
Material Type
“G”
Max Recommended Voltage
265Vrms
D
8.0
±
0.5 mm
T
4.0
±
0.5 mm
Lead Diameter
0.6
±
0.1 mm
S
5.08 +0.6 mm /
-0.1 mm
L
12.7
±
1.0 mm
Coating Run Down
Above the Kink
3.50
±
0.3 mm
B
5.0
±
0.50 mm
C
2.8
±
0.3 mm
L
OUTSIDE
KINKED LEADS
S
STRAIGHT
LEADS
B
INSIDE
KINKED LEADS
S
S
D
D
D
C
T