background image

                         

 

DATA SHEET

 

Ametherm, Inc

.  3111 N. Deer Run Road #4 Carson City, NV  89701 

Telephone: (800) 808-2434   (775) 884-2434     Fax:  (775) 884-0670

 

www.ametherm.com 

 

Part Number: SL22 10007

 

 

Ordering Different Lead Types:

 

 

 
 

For example: to order an inside kinked lead use part number SL22 10007-

A

 

 

 

     

 
 

 

 
 
 

 
 
 
 

 

Electrical 

Specifications: 

      

 

Mechanical 

Specifications: 

 

 
 
 
 
 
 
 
 

UL File Number:  #E209153 

 

 

 

 

 

       Revision Date: March 19, 2003 

Inside Kinked Leads 

Use 

-A

 after Ametherm’s part # 

Outside Kinked Leads 

Use 

-B

 after Ametherm’s part # 

Resistance @ 25°C 

10.0 

 

±

 20% 

Max Steady State Current Up to 65

°

7.0 A 

Max Recommended Voltage 

265 Vrms 

Max Recommended Energy Rating (Joules) 

90.0 J 

Actual Failure Point of Instantaneous Energy (Joules) 

200.0 J 

Resistance @ 100% of Max Current 

0.122 

 

Resistance @ 50% of Max Current 

0.242 

 

Body Temperature @ 100% Current Rating 

172 °C 

Dissipation Constant 

32.4mW/°C 

Thermal Time Constant 

122 seconds 

Material Type 

“H” 

Max Recommended Capacitance @ 120/240/440 VAC 

6000

µ

F/1500

µ

F/

450

µ

20.0 

±

 1.0 mm 

5.0 

±

 0.5 mm 

Lead Diameter 

1.0 

±

 0.1 mm 

7.5 

±

 0.80 mm 

38.0 

±

 9.0 mm 

Straight Leads 
Coating Run Down 

5.0 

±

 1.0 mm 

9.35 

±

 0.85 mm 

3.82 

±

 1.0 mm 

L

OUTSIDE

KINKED LEADS

S

STRAIGHT

LEADS

B

INSIDE

KINKED LEADS

S

S

D

D

D

C

T