background image

CATALOG

Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved.

313948AE1/13Original  © 2013

ADC, AirES, AMP, AMP NETCONNECT, AMPINNERGY, AMPMODU, AMP-TWIST, Compact Building, 

CopperTen,  Express  Exit,  FiberGuide,  FL2000,  HighBand,  KRONE,  LightCrimp  PLUS,  

LSA-PLUS, MPO Optimate, MRJ21,  MT-RJ SECURE, NETCONNECT, NETpodium, OMX, OPTIMATE, 

Pro-Crimper, Quareo, Quick-Fit, RapidReel, RealFlex, RJ45, Sigma-Link, SlimLine, Snap-Fit, TracerLight, TrueNet, Tyco, Ultim8, TE Connectivity, 

TE connectivity (logo), Tyco Electronics, and TE (logo) are trademarks. 

 

While TE Connectivity has made every reasonable effort to ensure the accuracy of the information in this document, TE Connectivity does 

not guarantee that it is error-free, nor does TE Connectivity make any other representation, warranty or guarantee that the information is 

accurate, correct, reliable or current. TE Connectivity reserves the right to make any adjustments to the information contained herein at 

any time without notice. TE Connectivity expressly disclaims all implied warranties regarding the information contained herein, including, 

but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are 

for  reference  purposes  only  and  are  subject  to  change  without  notice.  Specifications  are  subject  to  change  without  notice.  Consult 

TE Connectivity for the latest dimensions and design specifications.

1st Edition

TE Connectivity Enterprise Networks

Product Catalog

Featuring AMP NETCONNECT

and TrueNet product brands

Contact us:

Greensboro, NC 
USA 27409-8420
Tel: 1-800-553-0938 
Fax: 1-717-986-7406

www.te.com/EnterpriseNetworks

Ent

erprise Netw

orks Pr

oduct Ca

talog

          1s

t E
dition          

w

w

w

.te

.c

om/Ent

erpriseNetw

orks

Sc0_Cover_TOC_v1_COMBINED.indd   4

12/18/12   12:49 PM

Tyco-catalog-AMP-2013-html.html
background image

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

TE Connectivity Enterprise Networks

Warranty

IT’S STANDARD EQUIPMENT

This coverage is automatically part of the package when*:

•  TE Connectivity products are specifi ed end-to-end

•  A TE Connectivity authorized Network Design & Installation (ND&I) contractor registers the network project with TE

•  That ND&I performs the actual installation in accordance with TE requirements

WHO’S COVERED

Unlike most systems suppliers, TE provides warranty coverage directly to the end user. Many suppliers provide coverage to the 
installers, who then provide coverage to the customer. But with TE warranties, there are no middlemen. The warranties are between 
you and TE Connectivity.

For more information, please visit: www.te.com/aboutus/pdf/tc.pdf
Or call: 1-800-553-0938
Outside the U.S., please contact your local TE product sales offi

  ce.

People & Products to Answer the Cabling Challenge.

Network communications infrastructure implementations are complicated regardless of the business you're in. You need the right 
resources, products and services to achieve the high performance, fl exible environment your business and end users demand. AT 
TE Connectivity, we off er custom network infrastructure cabling products and solutions that can help you now and for years to 
come. Our in-depth technical expertise combined with our more than 70 years in the industry has made us the leading provider of 
premise cabling solutions. TE has one of the most diverse and complete product sets for a wide range of network needs including 
power, data, voice, video, IP and more.

More than just the technology you need, TE helps ensure the solutions are eff ectively and effi

  ciently installed by working with our 

distributors and customers in a hands-on design process. You get the solutions you need when and where you need them and 
have them installed through our network of certifi ed installation contractors.

Optimize your network performance, increase productivity and benefi t from a more immediate return on your infrastructure 
investment with TE Enterprise Networks solutions that are engineered smarter, faster and better.

*Some conditions may apply. Contact TE customer service for more information at 800-553-0938.

25 Year System Performance Coverage*

We are confi dent that your TE Connectivity (TE) Enterprise Network cabling system will keep performing to 
current TIA/EIA industry standards. If the registered system ever fails to meet those standards within 25 years 
of the date of installation, we’ll provide the reasonable parts and labor to replace or repair the TE product.

25 Year Component Coverage*

TE Connectivity also off ers a 25 Year Component Warranty to protect individual TE cabling system 
components. If a component fails within 25 years of the date of installation, we’ll provide the reasonable parts to 
replace or repair the registered TE product.

Sc0_Cover_TOC_v1_COMBINED.indd   5

12/18/12   12:50 PM

Tyco-catalog-AMP-2013-html.html
background image

I

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TE Connectivity Enterprise Networks

Table of Contents

FIBER .......................................................................................................................................................... 1-1

  Fiber Cable Assemblies ..........................................................................................................................................1-3
  Fiber Optic Cables and Field Terminated Connectors ..........................................................................1-18
  Fiber Enclosures  ........................................................................................................................................................1-53
  Storage Area Management (SAN Fiber Channel Management) .....................................................1-103
  Optical LAN Solution Supporting PON Technologies ...........................................................................1-106
  Fiber Optic Accessories and Tooling ...............................................................................................................1-124
  Fiber Optic Test Equipment .................................................................................................................................1-139
  Fiber Solution Reference Guide .........................................................................................................................1-142

SECURE NETWORK SOLUTIONS ....................................................................................................... 2-1

  Fiber Products .............................................................................................................................................................2-3
  Copper Products ........................................................................................................................................................2-17

COPPER ..................................................................................................................................................... 3-1

  Category 6A Products.............................................................................................................................................3-3
  Category 6 Products ................................................................................................................................................3-16
  Category 5e Products ..............................................................................................................................................3-32
  Copper Trunk Solutions  .........................................................................................................................................3-51
  Specialty Products .....................................................................................................................................................3-63
  Copper Accessories ..................................................................................................................................................3-101
  Copper Tooling  ...........................................................................................................................................................3-115
  Copper Solution Reference Guide ....................................................................................................................3-128

WORK AREA OUTLETS......................................................................................................................... 4-1

  Faceplates and Outlets ...........................................................................................................................................4-3
  Inserts ...............................................................................................................................................................................4-21

MANAGED CONNECTIVITY ................................................................................................................. 5-1

  ICM ......................................................................................................................................................................................5-3
  Quareo ..............................................................................................................................................................................5-7

CABLE MANAGEMENT .......................................................................................................................... 6-1

  Fiber Cable Raceway FiberGuide ......................................................................................................................6-3
  Equipment Racks  ......................................................................................................................................................6-18
  Horizontal and Vertical Cable Management ................................................................................................6-19
  Cable Management Accessories  ......................................................................................................................6-21

SUPPLEMENTARY SOLUTIONS .......................................................................................................... 7-1

  (Distributed Antenna Systems (DAS); Broadcast Products; Undercarpet Cabling; 
  Pre-Manufactured, Modular Power System; Residential Products)

TECHNICAL REFERENCE ..................................................................................................................... 8-1

INDEX  ........................................................................................................................................................ 9-1

  INDEX – PRODUCT NAME ....................................................................................................................................9-3
  INDEX – PART NUMBER ........................................................................................................................................9-15

Sc0_Cover_TOC_v1.indd   1

12/11/12   4:17 PM

Tyco-catalog-AMP-2013-html.html
background image

III

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Technology is everywhere we turn. Even the simplest action—making a phone 
call, connecting to the Internet, turning on a light, pushing the brake pedal in a 
car—sends power and data through hundreds of connections. We rely on these 
connections to work flawlessly every day. But what if they did something more? 
What if they could make technology faster, more efficient and smarter? At  
TE Connectivity (TE), our goal is to find innovative ways to solve our customers’ 
toughest connectivity challenges and help them make even bigger innovations 
possible. We believe “Every Connection Counts” and live it each day.

From education, healthcare and financial institutions, to hospitality, government and 
corporate organizations, every transaction, communication and facility operation 
is being accomplished with an ever-increasing number of devices and applications 
that connect to a data center, central office or communication closet. These 
organizations need to maintain and manage more connections than ever before 
throughout the physical layer infrastructure of the network. In the data center, the 
growing number of applications, virtual servers, storage devices and high-density 
switches also is requiring more connections in physical layer cross-connects 
between servers and switches. All of these connections—from the desktop to the 
data center—yield a much more complex physical layer. Today’s office networks 
are complex, media-rich environments. The addition of IP-based networks, wireless 
technology, video distribution systems and preparing for applications that could 
approach 10 – 40 – 100 GbE has become the new normal. 

TE’s Enterprise Networks portfolio supports data transmission at speeds of up to 
100 Gbps. Many of the world’s most complex networks run applications over TE 
products selected from our AMP NETCONNECT, KRONE and ADC TrueNet brands. 
TE offers best-in-class copper and fiber technology that helps network managers 
anticipate change, provide complete protection and support the bandwidth 
demands of their critical business applications now and in the future.

In a World Where Everything is Connected, Every Connection Counts.

Sc0_Cover_TOC_v1.indd   3

12/11/12   4:17 PM

Tyco-catalog-AMP-2013-html.html
background image

1-1

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Fiber Cable Assemblies ..................................................................................1-3

  Fiber Trunk Solutions ...................................................................................1-3

  Fiber Optic Patch Cords ..........................................................................1-14

Fiber Optic Cables and Field Terminated Connectors ................1-18

Fiber Enclosures ..............................................................................................1-53

  Q3000 ..............................................................................................................1-53

  RMG ....................................................................................................................1-55

  TFP ......................................................................................................................1-62

  Optical Distribution Frame Solutions .............................................. 1-72

  WMG ................................................................................................................. 1-90

  FL2000 .............................................................................................................1-93

  OMX ................................................................................................................. .1-101

Storage Area Management  
(SAN Fiber Channel Management) .....................................................1-103

Optical LAN Solution Supporting PON Technologies ..............1-106

Fiber Optic Accessories and Tooling ................................................. 1-124

Fiber Optic Test Equipment .................................................................... 1-139

Fiber Solution Reference Guide ............................................................ 1-142

Fiber Products

Sc1_Fiber_01_CableAssem_v1.indd   1

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

1-2

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

For decades, TE has been a leading global fiber infrastructure 
provider. TE fiber connectivity solutions assure smooth integration  
of new equipment for all networks, as well as long-term reliability  
and flexibility that are so critical for your business.

Optical fiber is the backbone of the world's global information 
infrastructure — the conduit enabling society's ever-increasing 
reliance on high-speed, media-rich communications. TE is 
a pioneer in optical communications technologies, making 
optical fiber more reliable, better performing, easier and 
more cost effective to install. With over seven decades of 
research, development and real-world deployment experience 
with our legacy brands including AMP, Raychem, ADC and 
Bell Laboratories, fiber is in our DNA. TE’s innovative fiber 
infrastructure solutions can help provide peak performance with 
solution-specific density, modularity and functionality. Due to 
the demands of today’s internet and mobile network boom, the 
amount of data transmitted at the enterprise business level is 
rapidly climbing as networks need to support more devices and 
advanced applications than ever before. Fiber counts are on the 
rise and TE solutions help you build a migration path to get from 
10GbE to 40 and 100GbE in a simple and cost-effective manner. 
TE's fiber product line can help you achieve a higher level of 
network understanding, manageability and security.

Sc1_Fiber_01_CableAssem_v1.indd   2

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

1-3

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber

Fiber Cable Assemblies 

Fiber Trunk Solutions

TE Connectivity's plug-and-play microcable trunk assemblies are round 12-fiber
optical trunk cables pre-terminated with a high-density MPO connector on both ends.
They can be used in conjuction with any of the other plug-and-play connectivity
products to rapidly deploy fiber into a data center or Local Area Network (LAN).
The microcable assemblies can simply be plugged into any plug-and-play cassette
or fiber enclosure which eliminates the need for on-site fiber termination.

FEATURES

• 

Available in OM3, OM4 and singlemode glass types

• 

Round design eliminates preferential bend issues which results in increased
density and greater manageability

• 

Compatible with FiberGuide optical raceway system to add increased
protection and manageability

• 

Pulling socks and stealth pulling eye protect MPO connectors during installation

• 

Factory terminated and tested

MPO Microcable Trunk Assembles 

Part Number

OM4 MPO Microcable Trunk Assemblies

  OM4 MPO-MPO, 12-fiber 3 mm interconnect, plenum (OFNP) rated

MPA-NCNCJ40xxxF-yy

  OM4 MPO-MPO, 24-fiber backbone (2x12) with 3 mm interconnect subunits, OFNP/OFNP

MPA-NCNCD40xxxF-yy

OM3 MPO Microcable Trunk Assemblies

  OM3 MPO-MPO, 12-fiber 3 mm interconnect, plenum (OFNP) rated

MPA-NCNCJ30xxxF-yy

  OM3 MPO-MPO, 24-fiber backbone (2 x 12) with 3 mm interconnect subunits, OFNR/OFNP

MPA-NCNCD30xxxF-yy

OM2 MPO Microcable Trunk Assemblies

  OM2 MPO-MPO, 12-fiber 3 mm interconnect, plenum (OFNP) rated 

MPA-NCNCJ20xxxF-yy

  OM2 MPO-MPO, 24 (2 x 12) with 3 mm interconnect subunits, OFNR/OFNP

MPA-NCNCD20xxxF-yy

OM1 MPO Microcable Trunk Assemblies

  OM1 MPO-MPO, 12-fiber 3 mm interconnect, plenum (OFNP) rated

MPA-NCNCJ10xxxF-yy

  OM1 MPO-MPO, 24-fiber backbone (2 x 12) 3 mm interconnect subunits, OFNR/OFNP

MPA-NCNCD10xxxF-yy

Singlemode Microcable Trunk Assemblies

  OS2 Single Mode, 12-fiber, 12-fiber 3 mm interconnect, plenum (OFNP) rated

MPA-NCNCJ50xxxF-yy

   OS2 Single Mode, 24-fiber, 24 (2 x 12) Fiber backbone with 3 mm interconnect subunits,  

plenum (OFNP) rated

MPA-NCNCD50xxxF-yy

ORDERING INFORMATION

Note: xxx denotes length in feet of overall trunk, 001=1 foot, 010=10 feet, 100=100 feet
Note: yy denotes breakout definition for each end 
SS=Standard, AA=TFP to TFP, AB=TFP to ODF, BB=ODF to ODF, FF=RMG to RMG, NN=No breakout 
for 12-fiber interconnect cable 

SAM MPO Cable Assemblies

Sc1_Fiber_01_CableAssem_v1.indd   3

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-4

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

OM4 High Fiber Count Trunks

Part Number

 24-fiber, MPO-MPO (no pins) 3 mm round, OFNP rated

MPA-NCNCD40xxxF-yy

 24-fiber, MPO-MPO (no pins) 3 mm dual zip, OFNP rated

MPA-NCNCZ40xxxF-yy

 48-fiber, MPO-MPO (no pins) 3mm round, OFNP rated

MPA-NCNC440xxxF-yy

 72-fiber, MPO-MPO (no pins) 3 mm round, OFNP rated

MPA-NCNC740xxxF-yy

 96-fiber, MPO-MPO (no pins) 3 mm round, OFNP rated

MPA-NCNC940xxxF-yy

OM3 High Fiber Count Trunks

 24-fiber, MPO-MPO (no pins) 3 mm round, OFNP rated

MPA-NCNCD30xxxF-yy

 24-fiber, MPO-MPO (no pins) 3 mm dual zip, OFNP rated

MPA-NCNCZ30xxxF-yy

 48-fiber, MPO-MPO (no pins) 3 mm round, OFNP rated

MPA-NCNC430xxxF-yy

 72-fiber, MPO-MPO (no pins) 3 mm round, OFNP rated

MPA-NCNC730xxxF-yy

 96-fiber, MPO-MPO (no pins) 3 mm round, OFNP rated

MPA-NCNC930xxxF-yy

Singlemode High Fiber Count Trunks

 24-fiber, MPO-MPO (no pins) 3 mm round, OFNP rated

MPA-NCNCD50xxxF-yy

 24-fiber, MPO-MPO (no pins) 3 mm dual zip, OFNP rated

MPA-NCNCZ50xxxF-yy

 48-fiber, MPO-MPO (no pins) 3 mm round, OFNP rated

MPA-NCNC450xxxF-yy

 72-fiber, MPO-MPO (no pins) 3 mm round, OFNP rated

MPA-NCNC750xxxF-yy

 96-fiber, MPO-MPO (no pins) 3 mm round, OFNP rated

MPA-NCNC950xxxF-yy

TE’s TrueNet high fiber count plug-and-play trunks provide the backbone
cabling for the TrueNet Plug-and-Play system. These high count trunk
cables come pre-terminated with a high-density MPO connectors on both
ends and provide an easy and efficient way to pull large numbers of fibers
at one time to help in the rapid deployment of the TrueNet Plug-and-
Play system either in the data center or Local Area Network (LAN). Each
trunk has custom breakouts designed to work with the TE TrueNet Plug-
and-Play connectivity. The TrueNet high fiber count trunks can simply be
plugged into any plug-and-play cassette in the optical distribution frame
or fiber enclosure which eliminates the need for on-site fiber termination
and preparation.

FEATURES

• 

Construction of rugged loose-tube fiber cable

• 

Ship with a pulling sock on one end to aid with installation

• 

Cable assemblies contain OFNP flame rated cable

• 

Breakouts specifically designed to work with TE TrueNet plug-and-play connectivity

TE’s TrueNet High Fiber Count Plug-and-Play Trunks

ORDERING INFORMATION

Note: xxx denotes length in feet of overall trunk, 001=1 foot, 010=10 feet, 100=100 feet 
Note: yy denotes breakout definition for each end 
SS=Standard, AA=TFP to TFP, AB=TFP to ODF, BB=ODF to ODF, FF=RMG to RMG

Sc1_Fiber_01_CableAssem_v1.indd   4

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-5

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

OM4 High Fiber Count Trunks

Part Number

  MPO pinned - LC; 18" breakout; 3 m length

MPA-PCLCJ40003M-18

  MPO pinned - LC; 18" breakout; 4 m length

MPA-PCLCJ40004M-18

  MPO pinned - LC; 18" breakout; 5 m length

MPA-PCLCJ40005M-18

  MPO pinned - SC; 18" breakout; 3 m length

MPA-PCSCJ40003M-18

  MPO pinned - SC; 18" breakout; 4 m length

MPA-PCSCJ40004M-18

  MPO pinned - SC; 18" breakout; 5 m length

MPA-PCSCJ40005M-18

OM3 High Fiber Count Trunks

  MPO pinned - LC; 18" breakout; 3 m length

MPA-PCLCJ30003M-18

  MPO pinned - LC; 18" breakout; 4 m length

MPA-PCLCJ30004M-18

  MPO pinned - LC; 18" breakout; 5 m length

MPA-PCLCJ30005M-18

  MPO pinned - SC; 18" breakout; 3 m length

MPA-PCSCJ30003M-18

  MPO pinned - SC; 18" breakout; 4 m length

MPA-PCSCJ30004M-18

  MPO pinned - SC; 18" breakout; 5 m length

MPA-PCSCJ30005M-18

Singlemode High Fiber Count Trunks

  MPO pinned - LC/UPC; 18" breakout; 3 m length

MPA-PCLCJ50003M-18

  MPO pinned - LC/UPC; 18" breakout; 4 m length

MPA-PCLCJ50004M-18

  MPO pinned - LC/UPC; 18" breakout; 5 m length

MPA-PCLCJ50005M-18

  MPO pinned - SC/UPC; 18" breakout; 3 m length

MPA-PCSCJ50003M-18

  MPO pinned - SC/UPC; 18" breakout; 4 m length

MPA-PCSCJ50004M-18

  MPO pinned - SC/UPC; 18" breakout; 5 m length

MPA-PCSCJ50005M-18

TE’s TrueNet 12-fiber plug-and-play array cables provide a convenient and efficient
method to connect active equipment into the network. These 12-fiber round 3 mm
cables contain a pre-terminated high-density MPO pinned connector on one end
and either LC or SC connectors on the other. The TrueNet 12-fiber plug-and-play
array cable assemblies can simply be plugged into any plug-and-play cassette
in the optical distribution frame or fiber enclosure which eliminates the need for
on-site fiber termination and preparation.

TE’s TrueNet High Fiber Count Plug-and-Play Array Cables

ORDERING INFORMATION

FEATURES

• 

Round design with outer diameter of 3 mm eliminates preferential bend issues which
results in increased density and greater manageability

• 

Each LC or SC leg is clearly labeled and identified

• 

Custom lengths available upon request

• 

Standard breakout length is 18 inches, which is optimum to connect to active equipment

Sc1_Fiber_01_CableAssem_v1.indd   5

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-6

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Trunk Configurator

Part Number

MP__ – __ __ __ __ __ __ __ __ __ __ __ – __ __

OM1

J1

12-Fiber 3mm Interconnect, OFNP

11

12-Fiber backbone, 1x12F, 3mm 

Interconnect Subunit, OFN

D1

24 Fiber backbone, 2x12F, 3mm 

Interconnect Subunits, OFNP

OM3

J3

12-Fiber 3mm Interconnect, OFNP

13

12-Fiber backbone, 1x12F, 3mm 

Interconnect Subunit, OFNP

D3

D3 24 Fiber backbone, 2x12F, 

3mm Interconnect Subunits, OFNP

M3

24 Fiber backbone, 1x12F, 3.8mm 

Interconnect Subunits, OFNP

OM4

J4

12-Fiber 3mm Interconnect, OFNP

14

12-Fiber backbone, 1x12F, 3mm 

Interconnect Subunit, OFNP

D4

24 Fiber backbone, 2x12F, 3mm 

Interconnect Subunits, OFNP

M4

24 Fiber backbone, 1x12F, 3.8mm 

Interconnect Subunits, OFNP

Single-mode

J5

12-Fiber 3mm Interconnect, OFNP

15

12-Fiber backbone, 1x12F, 3mm 

Interconnect Subunit, OFNP

D5

 24 Fiber backbone, 2x12F, 3mm 

Interconnect Subunits, OFNP

M5

24 Fiber backbone, 1x12F, 3.8mm 

Interconnect Subunits, OFNP

* Higher fiber counts available upon request

OM2

J2

12-Fiber 3mm Interconnect, OFNP

12

12-Fiber backbone, 1x12F, 3mm 

Interconnect Subunit, OFNP

D2

24 Fiber backbone, 2x12F, 3mm 

Interconnect Subunits, OFNP

Breakout Length (L2 & L3)

L2

L3

A

TFP

30.50"

B

NGF

13.75"

C

Customer length

18"

F

RMG

25"

N

No breakout

NA

S

Standard

36"

U

Customer length

79"

XX

Custom

10"-99"

Cable Jacket Color

0

Standard

C

Blue

N

Orange

G

Green

W

Brown

S

Slate

R

Red

Y

Yellow

V

Violet

P

Rose

A

Aqua

Cable Type

Use charts below

Assembly Length

001

Shortest possible length

999

Longest possible length

Unit of Measure

F

Feet

M

Meters

Performance/Polarity

C

Standard Performance Polarity C

A

 Standard Performance Poloarity A

B

Standard Performance Polarity B

T

OPTIMATE Polarity A

E

OPTIMATE Polarity C

F

OPTIMATE Polarity B

Connector A Type

N

12-Fiber MPO w/o pins

P

12-Fiber MPO w/pins

C

12-Fiber MPO Secure w/o pins

E

12-Fiber MPO Secure w/pins

1

24 Fiber MPO w/o pins

2

24 Fiber MPO w/ pins

A

24 Fiber MPO Secure w/pins

H

24 Fiber MPO Secure w/o pins

Connector B Type

N

12-Fiber MPO w/o pins

P

12-Fiber MPO w/pins

C

12-Fiber MPO Secure w/o pins

E

12-Fiber MPO Secure w/pins

1

24 Fiber MPO w/pins

2

24 Fiber MPO w/o pins

A

24 Fiber MPO Secure w/pins

H

24 Fiber MPO Secure w/o pins

L

LC Duplex

S

SC Duplex

T

ST Dual

F

FC Dual

M

MT-RJ plug w/o pins

8

LC Duplex Secure

9

MT-RJ plug Secure w/o pins

7

LC/APC Duplex

6

SC/APC Duplex

W

MT-RJ plug w/pins

0

Stub/pigtail

Connector A Color

C

Non-secure

W

Brown

0

Red

S

Slate

B

Blue

V

Violet

G

Green

P

Rose

Y

Yellow

A

Aqua

N

Orange

Connector B Color

C

Non-secure

W

Brown

0

Red

S

Slate

B

Blue

V

Violet

G

Green

P

Rose

Y

Yellow

A

Aqua

N

Orange

Sc1_Fiber_01_CableAssem_v1.indd   6

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-7

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

OM4

J4

12-Fiber 3mm Interconnect, OFNP

14

12-Fiber backbone, 1x12F, 3mm 

Interconnect Subunit, OFNP

D4

24 Fiber backbone, 2x12F, 3mm 

Interconnect Subunits, OFNP

M4

24 Fiber backbone, 1x12F, 3.8mm 

Interconnect Subunits, OFNP

Figure 3

12-fiber MPO to MPO assembly on 12-fiber backbone cable with 1x12 
fiber 3 mm interconnect subunit, or 24 fiber MPO to MPO assembly on 
24 fiber backbone cable with 1x24 fiber 3.8 mm interconnect subunit.

Figure 4  

MPO to MPO on backbone cable with 12-fiber 3 mm 
interconnect subunits. Fiber counts range from 12 to 144.

Figure 1

12-fiber MPO to MPO assembly on 3 mm interconnect cable or  
24 Fiber MPO to MPO assembly on 3.8 mm interconnect cable

Figure 2 

MPO to MPO assembly on 24 fiber 3 mm interconnect zipcord cable.

Cable Assembly Configuration

Figure 5

MPO to LC, SC, ST, FC, or MT-RJ. Fiber counts from 12 to 144 fibers.

Sc1_Fiber_01_CableAssem_v1.indd   7

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-8

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Assembly Length

Measured from tip of connector A ferrule to tip of connector B ferrule. The unit 
of measure is dependent on the selection in position 12. Each pair of subunits 
beyond the first two will be 2" longer on each end of the assembly, as shown 
(this allows a smaller pulling sock to be used).

Breakout Length

Choose the breakout length for each end. An entry of BF will result in 13.75" on 
the left and 25" on the right. The breakout length is defined from the end of the 
heat shrink transition to the tip of the connector ferrule as shown. The 7” section 
of exposed subunit shown here will exist on assemblies with any connector other 
than MPOs selected for connector B, and is non-configurable. Each pair of subunits 
beyond the first two will be 2" longer on each end of the assembly, as shown 
(this allows a smaller pulling sock to be used).

Sc1_Fiber_01_CableAssem_v1.indd   8

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-9

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Description

Connector A 

Fiber Number

Fiber Color

Connector B 

Fiber Number

Polarity A (Straight Through) 
with Standard Performance

1

Blue

1

2

Orange

2

3

Green

3

4

Brown

4

5

Slate

5

6

White

6

7

Red

7

8

Black

8

9

Yellow

9

10

Violet

10

11

Rose

11

12

Aqua

12

Polarity B (Reversed)  
with Standard Performance

1

Blue

12

2

Orange

11

3

Green

10

4

Brown

9

5

Slate

8

6

White

7

7

Red

6

8

Black

5

9

Yellow

4

10

Violet

3

11

Rose

2

12

Aqua

1

Polarity C (Pairs Flipped) 
with Standard Performance

1

Blue

2

2

Orange

1

3

Green

4

4

Brown

3

5

Slate

6

6

White

5

7

Red

8

8

Black

7

9

Yellow

10

10

Violet

9

11

Rose

12

12

Aqua

11

MPO to MPO Polarity for Cable Assemblies

Sc1_Fiber_01_CableAssem_v1.indd   9

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-10

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Connector B

Description

Connector A 

Fiber Number

Fiber Color

Fiber Number

Pair

Duplex  

Position

Polarity A  
(Straight  
Through)  
with  
Standard  
Performance

1

Blue

1

1

A

2

Orange

2

B

3

Green

3

2

A

4

Brown

4

B

5

Slate

5

3

A

6

White

6

B

7

Red

7

4

A

8

Black

8

B

9

Yellow

9

5

A

10

Violet

10

B

11

Rose

11

6

A

12

Aqua

12

B

Polarity C  
(Pairs  
Flipped) 
with  
Standard  
Performance

1

Blue

2

1

B

2

Orange

1

A

3

Green

4

2

B

4

Brown

3

A

5

Slate

6

3

B

6

White

5

A

7

Red

8

4

B

8

Black

7

A

9

Yellow

10

5

B

10

Violet

9

A

11

Rose

12

6

B

12

Aqua

11

A

Polarity for MPO to MT-RJ, LC, SC, ST, or FC

Polarity A must be chosen when connector B is a simplex connector (FC, ST, LC/APC, or SC/APC). 
OPTIMATE performance can only be chosen when connector B is MPO, LC, or SC. 

Sc1_Fiber_01_CableAssem_v1.indd   10

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-11

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Singlemode MPO

OS2

Connector

12F MPO

24F MPO

Insertion Loss
(dB Maximum)

1310 nm

0.50

0.75

1550 nm

0.50

0.75

Return Loss
(dB Minimum)

1310 nm

55

55

1550 nm

55

55

Multimode 12 and 24 Fiber MPO

OM1 (Table 1 of 2)

Assembly Length 

(meters)

20 m

>20 to 

40

>40 to 

60

>60 to 

80

>80 to 

100

>100 to 

120

>120 to 

140

>140 to 

160

Insertion Loss
(dB Maximum)

850 nm

0.50

0.57

0.63

0.70

0.76

0.83

0.89

0.96

1300 nm 

0.50

0.53

0.55

0.57

0.60

0.62

0.65

0.67

Return Loss
(dB Minimum)

850 nm

20

20

20

20

20

20

20

20

1300 nm

20

20

20

20

20

20

20

20

Multimode 12 and 24 Fiber MPO

OM1 (Table 2 of 2)

Assembly Length

(meters)

>160 to 

180

>180 to 

200

>200 to 

220

>220 to 

240

>240 to 

260

>260 to 

280

>280 to 

305

Insertion Loss
(dB Maximum)

850 nm

1.02

1.08

1.15

1.21

1.28

1.34

1.41

1300 nm

0.70

0.72

0.74

0.77

0.79

0.82

0.84

Return Loss
(dB Minimum)

850 nm

20

20

20

20

20

20

20

1300 nm

20

20

20

20

20

20

20

Multimode 12 and 24 Fiber MPO

OM2, OM3 and OM4 (Table 1 of 2)

Assembly Length

(meters)

20 m

>20 to 

40

>40 to 

60

>60 to 

80

>80 to 

100

>100 to 

120

>120 to 

140

>140 to 

160

Insertion Loss
(dB Maximum)

850 nm

0.50

0.57

0.63

0.70

0.76

0.83

0.89

0.96

1300 nm

0.50

0.53

0.55

0.57

0.60

0.62

0.65

0.67

Return Loss
(dB Minimum)

850 nm

23

23

23

23

23

23

23

23

1300 nm

23

23

23

23

23

23

23

23

Multimode 12 and 24 Fiber MPO

OM2, OM3, and OM4 (Table 2 of 2)

Assembly Length

(meters)

>160 to 

180

>180 to 

200

>200 to 

220

>220 to 

240

>240 to 

260

>260 to 

280

>280 to 

305

Insertion Loss
(dB Maximum)

850 nm

1.02

1.08

1.15

1.21

1.28

1.34

1.41

1300 nm

0.70

0.72

0.74

0.77

0.79

0.82

0.84

Return Loss
(dB Minimum)

850 nm

23

23

23

23

23

23

23

1300 nm

23

23

23

23

23

23

23

ASSEMBLY PERFORMANCE

Sc1_Fiber_01_CableAssem_v1.indd   11

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-12

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

ASSEMBLY PERFORMANCE

Multimode 12-fiber MPO OPTIMATE

OM3 and OM4 (Table 1 of 2)

Assembly Length

(meters)

20 m

>20 to 

40

>40 to 

60

>60 to 

80

>80 to 

100

>100 to 

120

>120 to 

140

>140 to 

160

Insertion Loss
(dB Maximum)

850 nm

0.35

0.42

0.48

0.55

0.61

0.68

0.74

0.81

Return Loss
(dB Minimum)

850 nm

28

28

28

28

28

28

28

28

Multimode 12-fiber MPO OPTIMATE

OM3 and OM4 (Table 2 of 2)

Assembly Length

(meters)

>160 to 

180

>180 to 

200

>200 to 

220

>220 to 

240

>240 to 

260

>260 to 

280

>280 to 

305

Insertion Loss
(dB Maximum)

850 nm

0.87

0.93

1.00

1.06

1.13

1.19

1.26

Return Loss
(dB Minimum)

850 nm

28

28

28

28

28

28

28

Multimode LC, SC, ST, and FC

OM1, OM2, OM3, and OM4 (Table 1 of 2)

Assembly Length

(meters)

20 m

>20 to 

40

>40 to 

60

>60 to 

80

>80 to 

100

>100 to 

120

>120 to 

140

>140 to 

160

Insertion Loss
(dB Maximum)

850 nm

0.35

0.42

0.48

0.55

0.61

0.68

0.74

0.81

1300 nm

0.35

0.38

0.40

0.42

0.45

0.47

0.50

0.52

Return Loss
(dB Minimum)

850 nm

20

20

20

20

20

20

20

20

1300 nm

20

20

20

20

20

20

20

20

Multimode LC, SC, ST, and FC

OM1, OM2, OM3, and OM4 (Table 2 of 2)

Assembly Length

(meters)

>160 to 

180

>180 to 

200

>200 to 

220

>220 to 

240

>240 to 

260

>260 to 

280

>280 to 

305

Insertion Loss
(dB Maximum)

850 nm

0.87

0.93

1.00

1.06

1.13

1.19

1.26

1300 nm

0.55

0.57

0.59

0.62

0.64

0.67

0.69

Return Loss
(dB Minimum)

850 nm

20

20

20

20

20

20

20

1300 nm

20

20

20

20

20

20

20

Sc1_Fiber_01_CableAssem_v1.indd   12

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-13

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Multimode LC, SC OPTIMATE

OM3, and OM4 (Table 1 of 2)

Assembly Length

(meters)

20 m

>20 to 

40

>40 to 

60

>60 to 

80

>80 to 

100

>100 to 

120

>120 to 

140

>140 to 

160

Insertion Loss
(dB Maximum)

850 nm

0.15

0.22

0.28

0.35

0.41

0.48

0.54

0.61

1300 nm

0.15

0.18

0.20

0.22

0.25

0.27

0.30

0.32

Return Loss
(dB Minimum)

850 nm

35

35

35

35

35

35

35

35

1300 nm

35

35

35

35

35

35

35

35

Multimode LC, SC OPTIMATE

OM3, and OM4 (Table 2 of 2)

Assembly Length

(meters)

>160 to 

180

>180 to 

200

>200 to 

220

>220 to 

240

>240 to 

260

>260 to 

280

>280 to 

305

Insertion Loss
(dB Maximum)

850 nm

0.67

0.73

0.80

0.86

0.93

0.99

1.06

1300 nm

0.35

0.37

0.39

0.39

0.44

0.44

0.49

Return Loss
(dB Minimum)

850 nm

35

35

35

35

35

35

35

1300 nm

35

35

35

35

35

35

35

Multimode MT-RJ

OM1, OM2, OM3, and OM4 (Table 1 of 2)

Assembly Length

(meters)

20 m

>20 to 

40

>40 to 

60

>60 to 

80

>80 to 

100

>100 to 

120

>120 to 

140

>140 to 

160

Insertion Loss
(dB Maximum)

850 nm

0.50

0.57

0.63

0.70

0.76

0.83

0.89

0.96

1300 nm

0.50

0.53

0.55

0.57

0.60

0.62

0.65

0.67

Return Loss
(dB Minimum)

850 nm

20

20

20

20

20

20

20

20

1300 nm

20

20

20

20

20

20

20

20

Multimode MT-RJ

OM1, OM2, OM3, and OM4 (Table 2 of 2)

Assembly Length

(meters)

>160 to 

180

>180 to 

200

>200 to 

220

>220 to 

240

>240 to 

260

>260 to 

280

>280 to 

305

Insertion Loss
(dB Maximum)

850 nm

1.02

1.08

1.15

1.21

1.28

1.34

1.41

1300 nm

0.70

0.72

0.74

0.77

0.79

0.82

0.84

Return Loss
(dB Minimum)

850 nm

20

20

20

20

20

20

20

1300 nm

20

20

20

20

20

20

20

Singlemode

Connector

LC, SC, 

ST, FC

MT-RJ

LC APC

SC APC,

FC APC

Insertion Loss
(dB Maximum)

1310 nm

0.30

0.50

0.20

0.30

1550 nm

0.30

0.50

0.20

0.30

Return Loss
(dB Minimum)

1310 nm

55

26

65

65

1550 nm

55

26

65

65

ASSEMBLY PERFORMANCE

Sc1_Fiber_01_CableAssem_v1.indd   13

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-14

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Optic Patch Cords 

As an integral part of the fiber product portfolio, TE Connectivity's fiber optic patch 
cords are essential to meet the needs of high-speed data networks. These patch 
cords can be used throughout the network in cross-connect, test or equipment areas 
to link optical equipment and are available in build to order lengths and components. 

FEATURES

• 

Fiber connector types available in multimode and singlemode include 
LC, SC, MTRJ, ST, and FC connectors featuring ceramic ferrules

• 

SECURE connectors available for LC and MTRJ

• 

Build to order configurations for any length fiber cable assembly

• 

Cable assemblies available in OFNP or OFNR ratings

• 

All patch cords are shipped with insertion loss tests for individual cords

• 

Factory terminated and tested

Sc1_Fiber_01_CableAssem_v1.indd   14

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-15

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Patch Cord Configurator

ORDERING INFORMATION

Part Number

PAT- __ __ __ __ – __ __ __ __ __ __ __ __ __

Connector A Color/Keying

C

Standard

B

Secure Blue

N

Secure Orange

G

Secure Green

W

Secure Brown

S

Secure Slate

R

Secure Red

Y

Secure Yellow

V

Secure Violet

P

Secure Rose

A

Secure Aqua

Connector B Color/Keying

C

None/Pigtails

0

None

B

Secure Blue

N

Secure Orange

G

Secure Green

W

Secure Brown

S

Secure Slate

R

Secure Red

Y

Secure Yellow

V

Secure Violet

P

Secure Rose

A

Secure Aqua

U

Universal

Cable Jacket Color

0

Standard

B

Blue

N

Orange

G

Green

W

Brown

S

Slate

R

Red

Y

Yellow

V

Violet

P

Rose

A

Aqua

Cable Jacket Material

P

Plenum

R

Riser

0

900 

µ

Fiber Type

1

OM1

2

OM2

3

OM3

4

OM4

5

OS2

Cable Type

A

1.6mm Zipcord

B

1.8mm Zipcord

C

2.0mm Zipcord

D

3.0mm Zipcoard

E

900

µ

F

2.0mm Simplex

Assembly Length

001

Shortest possible length

999

Longest possible length

Unit of Measure

F

Feet

M

Meters

Polarity

BLANK

Standard A to B Duplex

S

Straight A to A

Connector A Type

L

LC

S

SC

T

ST

F

FC

M

MTRJ w/o pins

W

MTRJ w/pins

3

LC Optimate Duplex

4

SC Optimate Duplex

5

FC APC

6

SC APC

7

LC APC

8

LC Secure Duplex

9

MT-RJ Secure Plug

Connector B Type

0

None

C

None/Pigtails

L

LC

S

SC

T

ST

F

FC

M

MTRJ w/o pins

W

MTRJ w/pins

3

LC Optimate Duplex

4

SC Optimate Duplex

5

FC APC

6

SC APC

7

LC APC

8

LC Secure Duplex

9

MT-RJ Secure Plug

Sc1_Fiber_01_CableAssem_v1.indd   15

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-16

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Description 

Part Number

OM3 and OM4 (50/125 

μ

m) Multimode

OM3 and OM4 (50/125 

μ

m) multimode LC cable assemblies

   OM3 2.0 mm zipcord LC-LC connectors

PAT-LCLC-P30CxxxM

   OM3 2.0 mm zipcord LC-SC connectors

PAT-LCSC-P30CxxxM

   OM3 2.0 mm zipcord LC-ST connectors

PAT-LCTC-P30CxxxM

   OM4 2.0 mm zipcord LC-LC connectors

PAT-LCLC-P40CxxxM

OM3 and OM4 (50/125 

μ

m) multimode MTRJ cable assemblies

   OM3 1.8 mm zipcord LC-MTRJ connectors

PAT-LCMC-P30BxxxM

   OM3 1.8 mm zipcord SC-MTRJ connectors

PAT-SCMC-P30BxxxM

OM3 and OM4 (50/125 

μ

m) multimode SC cable assemblies

   OM3 2.0 mm zipcord SC-SC connectors

PAT-SCSC-P30CxxxM

   OM4 2.0 mm zipcord SC-SC connectors

PAT-SCSC-P40CxxxM

   OM3 2.0 mm zipcord SC-ST connectors

PAT-SCTC-P30CxxxM

OM3 and OM4 (50/125 

μ

m) multimode ST cable assemblies

   OM3 2.0 mm zipcord ST-ST connectors

PAT-TCTC-P30CxxxM

OM2 (50/125 

μ

m) Multimode

OM2 (50/125 

μ

m) multimode LC cable assemblies

   OM2 2.0 mm LC-LC connectors

PAT-LCLC-P20CxxxM

   OM2 2.0 mm zipcord LC-SC connectors

PAT-LCSC-P20CxxxM

   OM2 2.0 mm zipcord LC-ST connectors

PAT-LCTC-P20CxxxM

OM2 (50/125 

μ

m) multimode MTRJ cable assemblies 

   OM2 1.8 mm zipcord LC-MTRJ connectors

PAT-LCMC-P20BxxxM

   OM2 1.8 mm zipcord SC-MTRJ connectors

PAT-SCMC-P20BxxxM

OM2(50/125 

μ

m) multimode SC cable assemblies

   OM2 2.0 mm zipcord SC-SC connectors

PAT-SCSC-P20CxxxM

   OM2 2.0 mm zipcord SC-ST connectors

PAT-SCTC-P20CxxxM

OM2 (50/125 

μ

m) multimode ST cable assemblies

   OM3 2.0 mm zipcord ST-ST connectors

PAT-TCTC-P30CxxxM

OM1 (62.5/125 

μ

m) Multimode

OM1 (62.5/125 

μ

m) multimode LC cable assemblies

   OM1 2.0 mm zipcord LC-LC connectors

PAT-LCLC-P10CxxxM

   OM1 2.0 mm zipcord LC-SC connectors

PAT-LCSC-P10CxxxM

   OM1 2.0 mm zipcord LC-ST connectors

PAT-LCTC-P10CxxxM

OM1 (62.5/125 

μ

m) multimode MTRJ cable assemblies

   OM1 1.8 mm zipcord LC-MTRJ connectors

PAT-LCMC-P10BxxxM

   OM2 1.8 mm zipcord SC-MTRJ connectors

PAT-SCMC-P10BxxxM

OM1 (62.5/125 

μ

m) multimode SC cable assemblies

   OM1 2.0 mm zipcord SC-SC connectors

PAT-SCSC-P10CxxxM

   OM1 2.0 mm zipcord SC-ST connectors

PAT-SCTC-P10CxxxM

OM1 (62.5/125 

μ

m ) multimode ST cable assemblies

   OM1 2.0 mm zipcord ST-ST connectors

PAT-TCTC-P10CxxxM

Singlemode

Singlemode LC cable assemblies

   OS2 2.0 mm zipcord LC-LC connectors

PAT-LCLC-PS0CxxxM

   OS2 2.0 mm zipcord LC-SC connectors

PAT-LCSC-PS0CxxxM

   OS2 2.0 mm zipcord LC-ST connectors

PAT-LCTC-PS0CxxxM

Singlemode MTRJ cable assemblies 

   OS2 1.8 mm zipcord LC-MTRJ connectors

PAT-LCMC-PS0BxxxM

   OS2 1.8 mm zipcord SC-MTRJ connectors

PAT-SCMC-PS0BxxxM

Singlemode SC cable assemblies

   OS2 2.0 mm zipcord SC-SC connectors

PAT-SCSC-PS0CxxxM

   OS2 2.0 mm zipcord SC-ST connectors

PAT-SCTC-PS0CxxxM

Singlemode ST cable assemblies

   OS2 2.0 mm zipcord ST-ST connectors

PAT-TCTC-PS0CxxxM

xxx = length in meters or feet

ORDERING INFORMATION

Sc1_Fiber_01_CableAssem_v1.indd   16

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Cable Assemblies 

1-17

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

ASSEMBLY PERFORMANCE

Multimode LC, SC, ST, and FC

(OM1, OM2, OM3, and OM4)

Assembly Length (meters)

20 m

>20 to 

40

>40 to 

60

>60 to 

80

>80 to 

100

Insertion Loss
(dB Maximum)

850 nm

0.35

0.42

0.48

0.55

0.61

1300 nm

.35

.38

.40

.42

.45

Return Loss
(dB Minimum)

850 nm

20

20

20

20

20

1300 nm

20

20

.01

20

20

Multimode LC, SC OPTIMATE

(OM3, and OM4)

Assembly Length (meters)

20 m

>20 to 

40

>40 to 

60

>60 to 

80

>80 to 

100

Insertion Loss
(dB Maximum)

850 nm

0.15

0.22

0.28

0.35

0.41

1300 nm

0.15

0.18

0.20

0.22

0.25

Return Loss
(dB Minimum)

850 nm

35

35

35

35

35

1300 nm

35

35

35

35

35

Multimode MT-RJ

Assembly Length (meters)

20 m

>20 to 

40

>40 to 

60

>60 to 

80

>80 to 

100

Insertion Loss
(dB Maximum)

850 nm

0.50

0.57

0.63

0.70

0.76

1300 nm

0.50

0.53

0.55

0.57

0.60

Return Loss
(dB Minimum)

850 nm

20

20

20

20

20

1300 nm

20

20

20

20

20

Singlemode

Connector

LC, SC, ST, FC

MT-RJ

LC APC

SC APC, FC APC

Insertion Loss
(dB Maximum)

1310 nm

0.30

0.50

0.20

0.30

1550 nm

0.30

0.50

0.20

0.30

Return Loss
(dB Minimum)

1310 nm

55

26

65

65

1550 nm

55

26

65

65

Sc1_Fiber_01_CableAssem_v1.indd   17

12/11/12   4:25 PM

Tyco-catalog-AMP-2013-html.html
background image

1-18

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber

Fiber Optic Cables and Field Terminated Connectors

Fiber Optic Cables and Field Terminated Connectors  

TE Connectivity's fi ber optic solutions off er a complete family of high-performance 
singlemode and multimode cables including indoor/outdoor cables, compact building 
cables, armored versions and patch cord pigtail cables. All cable is produced by 
highly automated manufacturing processes and each fi ber is tested to specifi cations 
after cabling to ensure consistent quality and dependability.

All multimode fi bers exceed IEEE 802.3z standards for Gigabit Ethernet performance. 
Fiber cable solutions also support IEEE 802.3ae standards for 300 meter 10 Gbps 
applications as well as 550 meter 10 Gbps applications. Advanced construction 
techniques simplify termination and allow faster installation. Each fi ber cable off ers 
low attenuation for optimum signal reliability while off ering excellent crush, cut and 
abrasion resistance.

TE Optical Fiber Cables are tested and designed to be the most recent applicable 
industry standards for premise cabling, network and telecommunications 
applications, including:

FEATURES

• 

Fiber optic cables contain fi bers for use in optical fi ber applications including: local 
area networks (LANs), wide area networks (WANs), fi ber to the curb (FTTC), fi ber 
to the home (FTTH), fi ber to the desk (FTTD) and others.

• 

TE Connectivity's optical fi ber system is a high-performance cabling system 
designed to meet or exceed the requirements of 10 Gigabit Ethernet application. 

• 

Optical fi ber cables are tested and designed to the most recent applicable industry 
standards for premise cabling, network and telecommunications applications.

• 

TE Connectivity's LightCrimp PLUS connectors off er easy installation with no epoxy 
or polishing required. Simply strip, cleave and crimp.

IEEE 802.3

Ethernet

Fast Ethernet

Gigabit Ethernet

10 Gigabit Ethernet

FDDI

ATM

Fibre Channel

Token Ring

ANSI/TIA-568

ISO 11801

ICEA-596

ICEA-640

ICEA-696

IEC 793-1

IEC 794-1

Telecordia GR-409-CORE Telecordia GR-20-CORE

Sc1_Fiber_02_CablesConnectors_v1.indd   18

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-19

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Zipcord

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Figure B

Multimode Optical Fiber
Interconnect Cable 

• 

Suitable for direct termination with
epoxy/polish, LightCrimp, LightCrimp
PLUS, and MT-RJ jacks for use
in pigtails, and patch cords

• 

Simplex and zipcord cables are
additionally suitable for use in
internal equipment connections

• 

Aramid yarn reinforcement

• 

UL and cUL listed OFNR (riser)
or OFNP (plenum)

• 

Outer jacket color: aqua

• 

Hybrid cables and other jacket
colors are available

• 

OS2 singlemode fi bers conform to
IEC 60793-2-10 B1.3 specifi cations
for low water peak OS2 fi bers

• 

See customer specifi cation 114-92001
at www.te.com/EnterpriseNetworks
for additional information

 OM3 and OM4 (50/125

µ

m) Multimode

Optical Fiber Interconnect Cable

Fiber
Tight
Buffering (900m)

Aramid Strength
Members

Outer Jacket

DuaLAN

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

QuadLAN

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Simplex

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Part Number

Cable Type

Fiber 

Count

Unit Count

Units (Fibers/Unit)

Figure

OM3
Riser (OFNR)

OM3
Plenum (OFNP)

OM4
Riser (OFNR)

OM4
Plenum (OFNP)

Simplex (2.0 mm)

1

1 (1)

3-1553406-9

3-1553407-9

4-1553406-9

4-1553407-9

Simplex (2.9 mm)

1

1 (1)

A

3-1553408-9

3-1553409-9

4-1553408-9

4-1553409-9

Zipcord (2.0 mm)

2

2 (1)

3-1553410-9

3-1553411-9

4-1553410-9

4-1553411-9

Zipcord (2.9 mm)

2

2 (1)

B

3-1553412-9

3-1553413-9

4-1553412-9

4-1553413-9

Dual (2.9 mm)

2

1 (2)

C

3-1553414-9

3-1553415-9

4-1553414-9

4-1553415-9

Dual (4.8 mm)

2

1 (2)

3-1553416-9

3-1553417-9

4-1553416-9

4-1553417-9

Quad (4.8 mm)

4

1 (4)

D

3-1553418-9

3-1553419-9

4-1553418-9

4-1553419-9

Figure A

Figure C

Figure D

ORDERING INFORMATION

Sc1_Fiber_02_CablesConnectors_v1.indd   19

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-20

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Part Number

Cable Type

Fiber Count

Unit Count Units (Fibers/Unit)

Figure

Riser (OFNR)

Plenum (OFNP)

Simplex (2.0 mm)

1

1 (1)

 1-1553406-2

 1-1553407-2

Simplex (2.9 mm)

1

1 (1)

A

 1-1553408-2

 1-1553409-2

Zipcord (2.0 mm)

2

2 (1)

 1-1553410-2

 1-1553411-2

Zipcord (2.9 mm)

2

2 (1)

B

 1-1553412-2

 1-1553413-2

Dual (2.9 mm)

2

1 (2)

C

 1-1553414-2

 1-1553415-2

Dual (4.8 mm)

2

1 (2)

 1-1553416-2

 1-1553417-2

Quad (4.8 mm)

4

1 (4)

D

 1-1553418-2

 1-1553419-2

ORDERING INFORMATION

50/125

µ

m OM2 Multimode Optical Fiber Interconnect Cable

Part Number

Cable Type

Fiber Count

Unit Count Units  (Fibers/Unit)

Figure

Riser (OFNR)

Plenum (OFNP)

Simplex (2.0 mm)

1

1 (1)

 1-1553406-1

 1-1553407-1

Simplex (2.9 mm)

1

1 (1)

A

 1-1553408-1

 1-1553409-1

Zipcord (2.0 mm)

2

2 (1)

 1-1553410-1

 1-1553411-1

Zipcord (2.9 mm)

2

2 (1)

B

 1-1553412-1

 1-1553413-1

Dual (2.9 mm)

2

1 (2)

C

 1-1553414-1

 1-1553415-1

Dual (4.8 mm)

2

1 (2)

 1-1553416-1

 1-1553417-1

Quad (4.8 mm)

4

1 (4)

D

 1-1553418-1

 1-1553419-1

ORDERING INFORMATION

 62.5/125

µ

m OM1 Multimode Optical Fiber Interconnect Cable

Zipcord

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Figure B

Simplex

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Figure A

Fiber
Tight
Buffering (900m)

Aramid Strength
Members

Outer Jacket

DuaLAN

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Fiber
Tight
Buffering (900m)

Aramid Strength
Members

Outer Jacket

Figure C

Figure D

QuadLAN

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Zipcord

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Figure B

Simplex

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Figure A

Figure D

QuadLAN

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Figure C

Fiber
Tight
Buffering (900m)

Aramid Strength
Members

Outer Jacket

DuaLAN

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Fiber
Tight
Buffering (900m)

Aramid Strength
Members

Outer Jacket

Sc1_Fiber_02_CablesConnectors_v1.indd   20

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-21

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Simplex

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Figure A

Figure D

QuadLAN

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Figure C

Fiber
Tight
Buffering (900m)

Aramid Strength
Members

Outer Jacket

DuaLAN

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Fiber
Tight
Buffering (900m)

Aramid Strength
Members

Outer Jacket

Figure B

Zipcord

Fiber

Tight
Buffering (900µm)

Aramid Strength
Members

Outer Jacket

Cable Type/Jacket Diameter

Fiber Count

Unit Count Units (Fibers/Unit)

Figure

Riser (OFNR)

Plenum (OFNP)

Simplex (2.0 mm)

1

1 (1)

 7-1553406-3

 7-1553407-3

Simplex (2.9 mm)

1

1 (1)

A

 7-1553408-3

 7-1553409-3

Zipcord (2.0 mm)

2

2 (1)

 7-1553410-3

 7-1553411-3

Zipcord (2.9 mm)

2

2 (1)

B

 7-1553412-3

 7-1553413-3

Dual (2.9 mm)

2

1 (2)

C

 7-1553414-3

 7-1553415-3

Dual (4.8 mm)

2

1 (2)

 7-1553416-3

 7-1553417-3

Quad (4.8 mm)

4

1 (4)

D

 7-1553418-3

 7-1553419-3

ORDERING INFORMATION

OS2 Singlemode Optical Fiber Interconnect Cable

Sc1_Fiber_02_CablesConnectors_v1.indd   21

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-22

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Multimode Optical Fiber Distribution Cable

• 

Suitable for horizontal and in-building backbone
cabling and for direct termination with epoxy/polish,
LightCrimp, LightCrimp PLUS and MT-RJ jacks

• 

Strippable 900

µ

m tight buff er coating allows

for easy connectorization

• 

TIA color-coded fi bers for easy identifi cation

• 

UL and cUL listed OFNR (riser) or OFNP (plenum)

• 

Outer jacket color: aqua

• 

Hybrid cables and other jacket colors are available

• 

OS1 singlemode fi bers conform to IEC 60793-2-
10B1.3 specifi cations for low water peak OS1 fi bers

• 

See customer specifi cation 114-92000 at:
www.te.com/EnterpriseNetworks
for additional information

Horizontal Distribution

Fibers

Tight Buffering (900µm)

Strength Members

Outer Jacket

Backbone Distribution

Fibers

Tight Buffering (900µm)

Strength Members

Outer Jacket

Binder

Dielectric Central
Strength Member

Protective Jacket

12-Fiber Cable Cross Section

72-Fiber Cable Cross Section

Figure A

Figure C

Figure B

OM3 and OM4 (50/125

µ

m) Multimode Optical Fiber Distribution Cable

Part Number

Fiber Count

Unit Count

Unit (Fibers/Unit)

Figure

OM3
Riser (OFNR)

OM3
Plenum (OFNP)

OM4
Riser (OFNR)

OM4
Plenum (OFNP)

6

1 (6)

A

3-1553307-9

3-1553308-9

4-1553307-9

4-1553308-9

8

1 (8)

3-1553309-9

3-1553310-9

4-1553309-9

4-1553310-9

12

1 (12)

3-1553311-9

3-1553312-9

4-1553311-9

4-1553312-9

24

1 (24)

3-1553313-9

3-1553314-9

4-1553313-9

4-1553314-9

2 (12)

B

3-1553315-9

3-1553316-9

4-1553315-9

4-1553316-9

4 (6)

3-1553317-9

3-1553318-9

4-1553317-9

4-1553318-9

36

6 (6)

3-1553319-9

3-1553320-9

4-1553319-9

4-1553320-9

48

4 (12)

C

3-1553321-9

3-1553322-9

4-1553321-9

4-1553322-9

72

6 (12)

3-1553323-9

3-1553324-9

4-1553323-9

4-1553324-9

96

8 (12)

3-1553325-9

3-1553326-9

4-1553325-9

4-1553326-9

144

12 (12)

3-1553327-9

3-1553328-9

4-1553327-9

4-1553328-9

ORDERING INFORMATION

Sc1_Fiber_02_CablesConnectors_v1.indd   22

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-23

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

ORDERING INFORMATION

Part Number

Fiber 
Count

Unit Count Unit 

(Fibers/Unit)

Figure

Riser 
(OFNR)

Plenum 
(OFNP)

6

1 (6)

A

1-1553307-1

1-1553308-1

8

1 (8)

1-1553309-1

1-1553310-1

12

1 (12)

1-1553311-1

1-1553312-1

24

1 (24)

1-1553313-1

1-1553314-1

2 (12)

B

1-1553315-1

1-1553316-1

4 (6)

1-1553317-1

1-1553318-1

36

6 (6)

1-1553319-1

1-1553320-1

48

4 (12)

C

1-1553321-1

1-1553322-1

72

6 (12)

1-1553323-1

1-1553324-1

96

8 (12)

1-1553325-1

1-1553326-1

144

12 (12)

1-1553327-1

1-1553328-1

ORDERING INFORMATION

62.5/125

µ

m OM1 Multimode Optical Fiber Interconnect Cable

12-Fiber Cable Cross Section

72-Fiber Cable Cross Section

Figure A

Figure C

Figure B

Horizontal Distribution

Fibers

Tight Buffering (900µm)

Strength Members

Outer Jacket

Backbone Distribution

Fibers

Tight Buffering (900µm)

Strength Members

Outer Jacket

Binder

Dielectric Central
Strength Member

Protective Jacket

50/125

µ

m OM2 Multimode Optical Fiber Interconnect Cable

Part Number

Fiber Count

Unit Count Unit

 (Fibers/Unit)

Figure

Riser (OFNR)

Plenum (OFNP)

6

1 (6)

A

1-1553307-2

1-1553308-2

8

1 (8)

1-1553309-2

1-1553310-2

12

1 (12)

1-1553311-2

1-1553312-2

24

1 (24)

1-1553313-2

1-1553314-2

2 (12)

B

1-1553315-2

1-1553316-2

4 (6)

1-1553317-2

1-1553318-2

36

6 (6)

1-1553319-2

1-1553320-2

48

4 (12)

C

1-1553321-2

1-1553322-2

72

6 (12)

1-1553323-2

1-1553324-2

96

8 (12)

1-1553325-2

1-1553326-2

144

12 (12)

1-1553327-2

1-1553328-2

12-Fiber Cable Cross Section

72-Fiber Cable Cross Section

ORDERING INFORMATION

Figure A

Horizontal Distribution

Fibers

Tight Buffering (900µm)

Strength Members

Outer Jacket

Figure B

Figure C

Backbone Distribution

Fibers

Tight Buffering (900µm)

Strength Members

Outer Jacket

Binder

Dielectric Central
Strength Member

Protective Jacket

Sc1_Fiber_02_CablesConnectors_v1.indd   23

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-24

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

OS2 Singlemode Optical Fiber Interconnect Cable

12-Fiber Cable Cross Section

72-Fiber Cable Cross Section

Figure A

Figure C

Figure B

Fiber Count

Unit Count Unit (Fibers/Unit)

Figure

Riser (OFNR)

Plenum (OFNP)

6

1 (6)

A

7-1553307-3

7-1553308-3

8

1 (8)

7-1553309-3

7-1553310-3

12

1 (12)

7-1553311-3

7-1553312-3

24

1 (24)

7-1553313-3

7-1553314-3

2 (12)

B

7-1553315-3

7-1553316-3

4 (6)

7-1553317-3

7-1553318-3

36

6 (6)

7-1553319-3

7-1553320-3

48

4 (12)

C

7-1553321-3

7-1553322-3

72

6 (12)

7-1553323-3

7-1553324-3

96

8 (12)

7-1553325-3

7-1553326-3

144

12 (12)

7-1553327-3

7-1553328-3

ORDERING INFORMATION

Backbone Distribution

Fibers

Tight Buffering (900µm)

Strength Members

Outer Jacket

Binder

Dielectric Central
Strength Member

Protective Jacket

Horizontal Distribution

Fibers

Tight Buffering (900µm)

Strength Members

Outer Jacket

Sc1_Fiber_02_CablesConnectors_v1.indd   24

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-25

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

ORDERING INFORMATION

Multimode Interlocking Armor Optical Fiber Distribution Cable

• 

Robust construction provides extra protection for optical fi bers

• 

Interlocking armor enhances fl exibility

• 

Lightweight aluminum armor simplifi es handling

• 

Installer-friendly plenum rated over-jacketing makes cable pulls easier

• 

Outer/over jacketing color: aqua (OM3 and OM4); orange (OM2 and OM1);
yellow (singlemode)

• 

Hybrid cables and other jacket colors are available

• 

Pending local codes, may eliminate the need for innerduct

• 

OFCP (plenum) rated

• 

TIA color-coded fi bers

• 

Strippable 900

µ

m tight buff er coating allows for easy connectorization

• 

Indoor/Outdoor and specialty versions available

Fiber 
Count

Unit Count Units 

(Fibers/Unit)

UL/NEC 
Ratings

OM4
(50/125

µ

m)

(aqua)

OM3
(50/125

µ

m)

(aqua)

OM2 
(50/125

µ

m) 

(orange)

OM1 
(62.5/125

µ

m) 

(orange)

OS1 
Singlemode 
(yellow)

6

1 (6)

Plenum (OFCP)

7-1777121-7

3-1777121-7

2-1777121-7

1-1777121-7

4-1777121-7

12

1 (12)

Plenum (OFCP)

7-1777117-7

3-1777117-7

2-1777117-7

1-1777117-7

4-1777117-7

24

1 (24)

Plenum (OFCP)

4-1553420-9

3-1553420-9

1-1553420-2

1-1553420-1

7-1553420-3

2(12)

Plenum (OFCP)

7-1777122-7

3-1777122-7

2-1777122-7

1-1777122-7

4-1777122-7

48

4 (12)

Plenum (OFCP)

7-1777123-7

3-1777123-7

2-1777123-7

1-1777123-7

4-1777123-7

72

6 (12)

Plenum (OFCP)

7-1777124-7

3-1777124-7

2-1777124-7

1-1777124-7

4-1777124-7

 

  

Sc1_Fiber_02_CablesConnectors_v1.indd   25

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-26

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Multimode Optical Fiber Indoor/Outdoor Cable

• 

Suitable for in-building and inter-building backbone cabling

• 

Can eliminate the need for a transition point and splicing when entering
buildings – go directly from outdoors into building riser or plenum spaces

• 

Water-blocked buff er tube for water penetration protection

• 

Flame-retardant UV-protected jacket for harsh outdoor environments

• 

All-dielectric construction

• 

UL and cUL listed OFNR (riser) or OFNP (plenum)

• 

Single loose tube cables:

– TIA color-coded fi bers for easy identifi cation

– Water-blocked buff er tube for water penetration protection

– Small diameter single tube construction saves space inside ducts

• 

Stranded loose tube cables:

– Outer jacket color is black for all fi ber types

– Hybrid cables and other jacket colors are available

– Reverse oscillating lay construction for easy midspan access

– Dry water blocking technology

– TIA color-coded fi bers in TIA color-coded tubes for easy identifi cation

• 

See customer specifi cation 114-92002 at:
www.te.com/EnterpriseNetworks for additional information

OM3 and OM4 (50/125

µ

m) Multimode Optical Fiber Indoor/Outdoor Cable

Indoor/Outdoor CLT

(CampusLink)

Fibers

Water-blocked Buffer Tube

Outer Jacket

Strength Members

Part Number

Cable Type

 Fiber 
Count

Unit Count

Unit (Fibers/Unit)

Figure

OM3

(50/125

µ

m)

Riser (OFNR)

OM3

(50/125

µ

m)

Plenum (OFNP)

OM4

(50/125

µ

m)

Riser (OFNR)

OM4

(50/125

µ

m)

Plenum (OFNP)

Single Loose Tube

6

1 (6)

A

6-1553342-4

6-1553343-4

6-1553342-5

6-1553343-5

8

1 (8)

6-1553344-4

6-1553345-4

6-1553344-5

6-1553345-5

12

1 (12)

B

6-1553346-4

6-1553347-4

6-1553346-5

6-1553347-5

Stranded Loose Tube

24

2 (12)

6-1553348-4

6-1553349-4

6-1553348-5

6-1553349-5

36

 3 (12)

6-1553350-4

6-1553351-4

6-1553350-5

6-1553351-5

48

4 (12)

C

6-1553352-4

6-1553353-4

6-1553352-5

6-1553353-5

72

6 (12)

6-1553354-4

6-1553355-4

6-1553354-5

6-1553355-5

96

 8 (12)

6-1553356-4

6-1553357-4

6-1553356-5

6-1553357-5

144

12 (12)

6-1553358-4

6-1553359-4

6-1553358-5

6-1553359-5

Indoor/Outdoor SLT

(FirstLink)

Fibers

Water-Blocking Outer
Strength Members

Outer Jacket

Flame Barrier Tapes

Water-Blocked Buffer Tube

Dielectric Central
Strength Member

12-Fiber Cable Cross Section

144-Fiber Cable Cross Section

Figure A

Figure C

Figure B

ORDERING INFORMATION

Sc1_Fiber_02_CablesConnectors_v1.indd   26

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-27

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Part Number

Cable Type

 Fiber 
Count

Unit Count

Unit (Fibers/Unit)

Figure

OM3

(50/125

µ

m) 

Riser (OFNR)

OM3

(50/125

µ

m) 

Plenum (OFNP)

OM4

(50/125

µ

m) 

Riser (OFNR)

OM4

(50/125

µ

m) 

Plenum (OFNP)

Single Loose Tube

6

1 (6)

A

6-1553342-4

6-1553343-4

6-1553342-5

6-1553343-5

8

1 (8)

6-1553344-4

6-1553345-4

6-1553344-5

6-1553345-5

12

1 (12)

B

6-1553346-4

6-1553347-4

6-1553346-5

6-1553347-5

Stranded Loose Tube

24

2 (12)

6-1553348-4

6-1553349-4

6-1553348-5

6-1553349-5

36

 3 (12)

6-1553350-4

6-1553351-4

6-1553350-5

6-1553351-5

48

4 (12)

C

6-1553352-4

6-1553353-4

6-1553352-5

6-1553353-5

72

6 (12)

6-1553354-4

6-1553355-4

6-1553354-5

6-1553355-5

96

 8 (12)

6-1553356-4

6-1553357-4

6-1553356-5

6-1553357-5

144

12 (12)

6-1553358-4

6-1553359-4

6-1553358-5

6-1553359-5

ORDERING INFORMATION

ORDERING INFORMATION

Cable 
Type

Fiber 

Count

Unit Count  

Units  

(Fibers/Unit) Figure

OM2  
(50/125

µ

m) 

Riser (OFNR)

OM2  
(50/125

µ

m) 

Plenum 
(OFNP)

OM1  
(62.5/125

µ

m) 

Riser (OFNR)

OM1  
(62.5/125

µ

m) 

Plenum 
(OFNP)

OS2  
Singlemode 
Riser (OFNR)

OS2  
Singlemode 
Plenum (OFNP)

Single 
Loose 
Tube

6

1 (6)

A

6-1553342-2

6-1553343-2

6-1553342-1

6-1553343-1

6-1553342-3

6-1553343-3

8

1 (8)

6-1553344-2

6-1553345-2

6-1553344-1

6-1553345-1

6-1553344-3

6-1553345-3

Standard 
Loose 
Tubet

12

1 (12)

B

6-1553346-2

6-1553347-2

6-1553346-1

6-1553347-1

6-1553346-3

6-1553347-3

24

2 (12)

6-1553348-2

6-1553349-2

6-1553348-1

6-1553349-1

6-1553348-3

6-1553349-3

36

3 (12)

6-1553350-2

6-1553351-2

6-1553350-1

6-1553351-1

6-1553350-3

6-1553351-3

48

4 (12)

C

6-1553352-2

6-1553353-2

6-1553352-1

6-1553353-1

6-1553352-3

6-1553353-3

72

6 (12)

6-1553354-2

6-1553355-2

6-1553354-1

6-1553355-1

6-1553354-3

6-1553355-3

96

8 (12)

6-1553356-2

6-1553357-2

6-1553356-1

6-1553357-1

6-1553356-3

6-1553357-3

144

12 (12)

6-1553358-2

6-1553359-2

6-1553358-1

6-1553359-1

6-1553358-3

6-1553359-3

 

  

OM2, OM1 and Singlemode Optical Fiber Indoor/Outdoor Cable

Sc1_Fiber_02_CablesConnectors_v1.indd   27

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-28

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Figure A

Dielectric SLT

Fibers

Water-Blocking Outer
Strength Members

Outer Jacket

Water-Blocking Materials

Dielectric Central
Strength Member

Buffer Tubes

Multimode Optical Fiber Outside Plant (OSP) Cable

• 

Suitable for inter-building backbone cabling (aerial, duct or direct burial)

• 

Dry water-blocking technology

• 

UV-protected jacket for harsh outdoor environment

• 

Low friction jacket for ease of pulling through ducts

• 

All-dielectric construction

• 

Outer jacket color is black

• 

See customer specifi cation 114-92003 at:
www.te.com/EnterpriseNetworks for additional information

• 

Single loose tube cables:

– TIA color-coded fi bers for easy identifi cation

– Small diameter single tube construction saves space inside ducts

• 

Stranded loose tube cables:

– Reverse oscillating lay construction for easy midspan access

– TIA color-coded fi bers and buff er tubes for easy identifi cation

Indoor/Outdoor CLT

(CampusLink)

Fibers

Water-blocked Buffer Tube

Outer Jacket

Strength Members

12-Fiber Cable Cross Section

144-Fiber Cable Cross Section

ORDERING INFORMATION

Fiber Count     Unit Count Units (Fibers/Unit)

Figure

OM4
(50/125

µ

m) 

OM3
(50/125

µ

m)

OM2 
(50/125

µ

m)

OM1 
(62.5/125

µ

m)

OS2 
Singlemode

4

1 (4)

6-1553386-5

6-1553386-4

6-1553386-2

6-1553386-1

6-1553386-3

6

1 (6)

6-1553387-5

6-1553387-4

6-1553387-2

6-1553387-1

6-1553387-3

8

1 (8)

6-1553388-5

6-1553388-4

6-1553388-2

6-1553388-1

6-1553388-3

12

1 (12)

6-1553389-5

6-1553389-4

6-1553389-2

6-1553389-1

6-1553389-3

24

2 (12)

6-1553390-5

6-1553390-4

6-1553390-2

6-1553390-1

6-1553390-3

36

3 (12)

6-1553391-5

6-1553391-4

6-1553391-2

6-1553391-1

6-1553391-3

48

4 (12)

6-1553392-5

6-1553392-4

6-1553392-2

6-1553392-1

6-1553392-3

72

6 (12)

6-1553393-5

6-1553393-4

6-1553393-2

6-1553393-1

6-1553393-3

96

8 (12)

6-1553394-5

6-1553394-4

6-1553394-2

6-1553394-1

6-1553394-3

144

12 (12)

A

6-1553395-5

6-1553395-4

6-1553395-2

6-1553395-1

6-1553395-3

  

Sc1_Fiber_02_CablesConnectors_v1.indd   28

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-29

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Count     Unit Count Units (Fibers/Unit)

Figure

OM4
(50/125

µ

m) 

OM3
(50/125

µ

m)

OM2 
(50/125

µ

m)

OM1 
(62.5/125

µ

m)

OS2 
Singlemode

4

1 (4)

6-1553386-5

6-1553386-4

6-1553386-2

6-1553386-1

6-1553386-3

6

1 (6)

6-1553387-5

6-1553387-4

6-1553387-2

6-1553387-1

6-1553387-3

8

1 (8)

6-1553388-5

6-1553388-4

6-1553388-2

6-1553388-1

6-1553388-3

12

1 (12)

6-1553389-5

6-1553389-4

6-1553389-2

6-1553389-1

6-1553389-3

24

2 (12)

6-1553390-5

6-1553390-4

6-1553390-2

6-1553390-1

6-1553390-3

36

3 (12)

6-1553391-5

6-1553391-4

6-1553391-2

6-1553391-1

6-1553391-3

48

4 (12)

6-1553392-5

6-1553392-4

6-1553392-2

6-1553392-1

6-1553392-3

72

6 (12)

6-1553393-5

6-1553393-4

6-1553393-2

6-1553393-1

6-1553393-3

96

8 (12)

6-1553394-5

6-1553394-4

6-1553394-2

6-1553394-1

6-1553394-3

144

12 (12)

A

6-1553395-5

6-1553395-4

6-1553395-2

6-1553395-1

6-1553395-3

  

Armored SLT

(Single Armor/Single Jacket)

Fibers

Outer Strength Members

Outer Jacket

Water-Blocking Materials

Dielectric Central
Strength Member

Water-blocked Buffer Tubes

Corrugated Armor

Multimode Optical Fiber Outside Plant Armored (OSPA) Cable

• 

Suitable for inter-building backbone cabling (aerial, duct or direct buried)

• 

Dry water-blocking technology

• 

UV-protected jacket for harsh outdoor environment

• 

Low friction jacket for ease of pulling through ducts

• 

Corrugated steel tape armor for rugged environments and rodent protection

• 

Outer jacket color is black for all fi ber types

• 

See customer specifi cation 114-92003 at:
www.te.com/EnterpriseNetworks for additional information

• 

Single loose tube cables:

– TIA color-coded fi bers for easy identifi cation

– Small diameter single tube construction saves space inside ducts

• 

Stranded loose tube cables:

– TIA color-coded fi bers and buff er tubes for easy identifi cation

– Reverse oscillating lay construction for easy midspan access

– Hybrid cables (with singlemode and multimode fi bers)

are available to provide a built-in migration path for future
applications that will require singlemode fi bers

Armored CLT

Fibers

Water-Blocking Outer

Strength Member s

Outer Jacket

Strength

Member s

Water-blocked Buffer Tube

Corrugated Armor

12-Fiber Cable Cross Section

144-Fiber Cable Cross Section

Figure A

Figure B

ORDERING INFORMATION

Cable Type

Fiber 

Count    

Unit Count Units 

(Fibers/Unit)

Figure

OM4
(50/125

µ

m) 

OM3
(50/125

µ

m)

OM2 
(50/125

µ

m)

OM1 
(62.5/125

µ

m)

OS2 
Singlemode

Single 
Loose Tube

4

1 (4)

6-1553396-5

6-1553396-4

6-1553396-2

6-1553396-1

6-1553396-3

6

1 (6)

A

6-1553397-5

6-1553397-4

6-1553397-2

6-1553397-1

6-1553397-3

8

1 (8)

6-1553398-5

6-1553398-4

6-1553398-2

6-1553398-1

6-1553398-3

12

1 (12)

6-1553399-5

6-1553399-4

6-1553399-2

6-1553399-1

6-1553399-3

Stranded 
Loose Tube

24

2 (12)

6-1553400-5

6-1553400-4

6-1553400-2

6-1553400-1

6-1553400-3

36

3 (12)

6-1553401-5

6-1553401-4

6-1553401-2

6-1553401-1

6-1553401-3

48

4 (12)

B

6-1553402-5

6-1553402-4

6-1553402-2

6-1553402-1

6-1553402-3

72

6 (12)

6-1553403-5

6-1553403-4

6-1553403-2

6-1553403-1

6-1553403-3

96

8 (12)

6-1553404-5

6-1553404-4

6-1553404-2

6-1553404-1

6-1553404-3

144

12 (12)

6-1553405-5

6-1553405-4

6-1553405-2

6-1553405-1

6-1553405-3

  

Sc1_Fiber_02_CablesConnectors_v1.indd   29

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-30

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Type

Gigabit Ethernet 
@ 850 nm

Gigabit Ethernet 
@ 1300 nm

Gigabit Ethernet  
@ 1310 nm

10 Gigabit Ethernet 
@ 850 nm

10 Gigabit Ethernet 
@ 1300 nm

10 Gigabit Ethernet 
@1310 nm

OM4  
(850 nm LO 50 

µ

m)  

Multimode

>800 m

550 m

550 m

300 m

OM3  
(850 nm LO 50 

µ

m)  

Multimode

800 m

550 m

300 m

300 m

OM2 (50/125 

µ

m)  

Multimode

550 m

550 m

82 m

300 m

OM1 (62.5/125 

µ

m) 

Multimode

300 m

550 m

33 m

300 m

Singlemode

5000 m

10000 m

Multimode Optical Fiber Performance

Cable Type

Fiber Type

Maximum  

Attenuation

dB/km

Maximum  

Attenuation

dB/km

OFL Bandwidth

MHz-km

Laser Bandwidth

MHz-km

850 nm

1300 nm 1310 nm

1550 nm

850 nm

1300 nm 850 nm

1300 nm

OM3 and OM4 indoor,  
Indoor/Outdoor, and OSP  
Loose Tube Cables

OM3 Multimode

3.2

1.2

1500

500

2000

OM4 Multimode

3.2

1.2

3500

500

4700

OM2 (50/125

µ

m) Indoor Cables

OM2 Multimode

3.5

1.5

500

500

OM2 (50/125

µ

m)  

Indoor/Outdoor and  
OSP Loose Tube Cables

OM2 Multimode

3.5

1.5

500

500

OM1 (62.5/125

µ

m) Indoor Cables

OM1 Multimode

3.5

1.2

200

500

OM1 (62.5/125

µ

m)  

Indoor/Outdoor and OSP  
Loose Tube Cables

OM1 Multimode

3.5

1.2

200

500

Singlemode Indoor Cables

Singlemode

0.5

0.5

Singlemode Indoor/Outdoor  
and OSP Loose Tube Cables

Singlemode

0.4

0.4

Multimode (850/1300 nm) and Singlemode (1310/1550 nm)
Optical Fiber Cable Performance Specifications

Sc1_Fiber_02_CablesConnectors_v1.indd   30

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-31

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Cable Type

Condition

Riser

Plenum

Interconnect (Tight Buffered) Cables

Storage

-40° C to +65° C (-40° F to +149° F)

-40° C to +65° C (-40° F to +149° F)

Operating

-20° C to +50° C (-4° F to +122° F)

-20° C to +50° C (-4° F to +122° F)

Installation

-20° C to +50° C (-4° F to +122° F)

-20° C to +50° C (-4° F to +122° F)

Indoor, Distribution (Tight Buffered) Cables

Storage

-40° C to +70° C (-40° F to +158° F)

-40° C to +70° C (-40° F to +158° F)

Operating

-20° C to +70° C (-4° F to +158° F)

0° C to +70° C (32° F to +158° F)

Installation

-10° C to +60° C (14° F to +140° F)

0° C to +60° C (32° F to +140° F)

Indoor/Outdoor Cables

Storage

-40° C to +70° C (-40° F to +160° F)

-40° C to +70° C (-40° F to +160° F)

Operating

-40° C to +70° C (-40° F to +160° F)

-40° C to +70° C (-40° F to +160° F)

Installation

-20° C to +60° C (-4° F to +140° F)

0° C to +60° C (-32° F to +140° F)

Stranded Cables

OSP (Loose Tube) Cables

Storage

-40° C to +70° C (-40° F to +158° F)

Operating

-40° C to +70° C (-40° F to +158° F)

Installation

-30° C to +60° C (-22° F to +140° F)

Optical Fiber Cable Temperature Ranges

Optical Fiber Cable Technical Information

Cable Type

Fiber 

Count

Unit Count

Units 

(Fibers/Unit)

Diameter mm (in)

Weight 

kg/km 
(lb/kft) 

Tensile Load N (lbf)        

Bending Radius mm (in)

Installation

Long Term

Installation

Long Term 

Outside Plant, 
Single Loose Tube

4

1 (4)

8.3 (0.33)

50 (34)

2670 (600)

890 (200)

176 (6.9)

88 (3.5)

6

1 (6)

8.3 (0.33)

50 (34)

2670 (600)

890 (200)

176 (6.9)

88 (3.5)

8

1 (8)

8.3 (0.33)

50 (34)

2670 (600)

890 (200)

176 (6.9)

88 (3.5)

12

1 (12)

8.3 (0.33) 

50 (34)

2670 (600)

890 (200)

176 (6.9)

88 (3.5)

Outside Plant, 
Stranded Loose 
Tube

24

2 (12)

11.0 (0.43)

100 (67)

2670 (600)

890 (200)

242 (9.5)

121 (4.8)

36

3 (12)

11.0 (0.43)

93 (62)

2670 (600)

890 (200)

242 (9.5)

121 (4.8)

48

4 (12)

11.0 (0.43)

97 (65)

2670 (600)

890 (200)

242 (9.5)

121 (4.8)

72

6 (12)

11.9 (0.47)

130 (87)

2670 (600)

890 (200)

252 (9.9)

126 (5.0)

96

8 (12)

13.6 (0.53)

158 (106)

2670 (600)

890 (200)

287 (11.3)

144 (5.6)

144

12 (12)

17.6 (0.69)

252 (169)

2670 (600)

890 (200)

364 (14.3)

182 (7.2)

Outside Plant, 
Armored Single 
Loose Tube

4

1 (4)

10.9 (0.43)

140 (94)

2670 (600)

890 (200)

244 (9.6)

122 (4.8)

6

1 (6)

10.9 (0.43)

140 (94)

2670 (600)

890 (200)

244 (9.6)

122 (4.8)

8

1 (8)

10.9 (0.43)

140 (94)

2670 (600)

890 (200)

244 (9.6)

122 (4.8)

12

1 (12)

10.9 (0.43)

140 (94)

2670 (600)

890 (200)

244 (9.6)

122 (4.8)

Outside Plant, 
Armored Stranded 
Loose Tube

24

2 (12)

13.8 (0.55)

214 (144)

2670 (600)

890 (200)

315 (12.4)

158 (6.2)

36

3 (12)

13.8 (0.55)

218 (146)

2670 (600)

890 (200)

315 (12.4)

158 (6.2)

48

4 (12)

13.8 (0.55)

223 (150)

2670 (600)

890 (200)

315 (12.4)

158 (6.2)

72

6 (12)

14.8 (0.58)

265 (178)

2670 (600)

890 (200)

335 (13.2)

167 (6.6)

96

8 (12)

16.7 (0.69)

307 (206)

2670 (600)

890 (200)

378 (14.9)

189 (7.4)

144

12 (12)

21.4 (0.84)

498 (335)

2670 (600)

890 (200)

455 (17.9)

228 (9)

Sc1_Fiber_02_CablesConnectors_v1.indd   31

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-32

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Optical Fiber Cable Technical Information (Continued)

Cable Type

Fiber 

Count

Unit Count

Units  

(Fibers/Unit)

UL/NEC 

Ratings

Diameter  
mm (in)

Weight kg/km  
(lb/kft) 

Tensile Load N (lbf)        

Bending Radius mm (in)

Installation Long Term Installation Long Term 

Interconnect, 
Simplex

1

1 (1)

OFNR

2.0 (0.08)

5 (3)

40 (9)

12 (3)

50 (1.97)

25 (0.98)

OFNP

2.0 (0.08)

6 (4)

40 (9)

12 (3)

50 (1.97)

25 (0.98)

OFNR

2.9 (0.11)

8 (5)

100 (22)

30 (7)

58 (2.3)

29 (1.1)

OFNP

2.9 (0.11)

9 (6)

100 (22)

30 (7)

58 (2.3)

29 (1.1)

Interconnect, 
Zipcord

2

2 (1)

OFNR

2.0 (0.08) x 4.1 (0.16)

8 (5)

40 (9)

12 (3)

50 (1.97)

25 (0.98)

OFNP

2.0 (0.08) x 4.1 (0.16)

10 (7)

40 (9)

12 (3)

50 (1.97)

25 (0.98)

OFNR

2.9  (0.11) x 5.9 (0.23)

15 (10)

100 (22)   

30 (7)

58 (2.3)

29 (1.1)

OFNP

2.9 (0.11) x 5.9 (0.23)

15 (10)

100 (22)

30 (7)

58 (2.3)

29 (1.1)

Interconnect, 
Dual

2

1 (2)

OFNR

2.9 (0.11)

7 (5)

100 (22)

30 (7)

57 (2.2)

29 (1.1)

OFNP

2.9 (0.11)

9 (6)

100 (22)

30 (7)

57 (2.2)

29 (1.1)

OFNR

4.8 (0.3)

20 (13)

100 (22)

30 (7)

96 (3.8)

48 (1.9)

OFNP

4.8 (0.3)

30 (20)

100 (22)

30 (7)

96 (3.8)

48 (1.9)

Interconnect, 
Quad

4

1 (4)

OFNR

4.8 (0.3)

25 (17)

100 (22)

30 (7)

96 (3.8)

48 (1.9)

OFNP

4.8 (0.3)

30 (20)

100 (22)

30 (7)

96 (3.8)

48 (1.9)

Distribution

6

1 (6)

OFNR

5.2 (0.20)

29 (19)

660 (150)

198 (45)

114 (4.5)

57 (2.2)

OFNP

4.8 (0.19)

24 (16)

440 (100)

132 (30)

110 (4.3)

55 (2.2)

8

1 (8)

OFNR

5.7 (0.22)

24 (16)

660 (150)

198 (45)

136 (5.4)

68 (2.7)

OFNP

5.0 (0.20)

26 (17)

440 (100)

132 (30)

110 (4.3)

55 (2.2)

12

1 (12)

OFNR

6.0 (0.24)

37 (25)

660 (150)

198 (45)

128 (5)

64 (2.5)

OFNP

5.7 (0.23)

46 (31)

440 (100)

132 (30)

128 (5)

64 (2.5)

24

1 (24)

OFNR

8.0 (0.31)

61 (41)

1320 (300) 396 (90)

178 (7)

89 (3.5)

OFNP

7.7 (0.30)

69 (46)

660 (150)

198 (45)

168 (6.6)

84 (3.3)

24

2 (12)

OFNR

7.4 x 13.0 (0.29 x 0.51)

87 (58)

1320 (300) 396 (90)

284 (11.2)

142 (5.6)

OFNP

7.0 x 12.4 (0.28 x 0.49) 92 (62)

660 (150)

198 (45)

264 (10.4)

132 (5.2)

24

4 (6)

OFNR

13.4 (0.53)

180 (121)

1320 (300) 396 (90)

275 (10.8)

137 (5.4)

OFNP

13.3 (0.52)

200 (134)

660 (150)

198 (45)

266 (10.5)

133 (5.2)

36

6 (6)

OFNR

16.4 (0.65)

220 (148)

1320 (300) 396 (90)

342 (13.5)

171 (6.7)

OFNP

16.0 (0.63)

255 (171)

660 (150)

198 (45)

327 (12.9)

164 (6.4)

48

4 (12)

OFNR

16.0 (0.63)

250 (168)

1320 (300) 396 (90)

350 (13.8)

175 (6.9)

OFNP

15.2 (0.60)

202 (136)

660 (150)

198 (45)

312 (12.3)

156 (6.1)

72

6 (12)

OFNR

18.9 (0.75)

301 (202)

1320 (300) 396 (90)

386 (15.2)

193 (7.6)

OFNP

18.5 (0.73)

316 (212)

660 (150)

198 (45)

386 (15.2)

193 (7.6)

96

8 (12)

OFNR

22.8 (0.90)

433 (291)

1320 (300) 396 (90)

462 (18.2)

231 (9.1)

OFNP

22.0 (0.86)

466 (313)

660 (150)

198 (45)

448 (17.6)

224 (8.8)

144

12 (12)

OFNR

24.8 (0.98)

461 (310)

1320 (300) 396 (90)

514 (20.2)

257 (10.1)

OFNP

24.2 (0.95)

474 (319)

660 (150)

198 (45)

514 (20.2)

257 (10.1)

Sc1_Fiber_02_CablesConnectors_v1.indd   32

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-33

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Optical Fiber Cable Technical Information (Continued)

Cable Type

Fiber 

Count

Unit Count

Units  

(Fibers/Unit)

UL/NEC 

Ratings

Diameter  
mm (in)

Weight kg/km  
(lb/kft) 

Tensile Load N (lbf)        

Bending Radius mm (in)

Installation Long Term Installation Long Term 

Interconnect, 
Simplex

1

1 (1)

OFNR

2.0 (0.08)

5 (3)

40 (9)

12 (3)

50 (1.97)

25 (0.98)

OFNP

2.0 (0.08)

6 (4)

40 (9)

12 (3)

50 (1.97)

25 (0.98)

OFNR

2.9 (0.11)

8 (5)

100 (22)

30 (7)

58 (2.3)

29 (1.1)

OFNP

2.9 (0.11)

9 (6)

100 (22)

30 (7)

58 (2.3)

29 (1.1)

Interconnect, 
Zipcord

2

2 (1)

OFNR

2.0 (0.08) x 4.1 (0.16)

8 (5)

40 (9)

12 (3)

50 (1.97)

25 (0.98)

OFNP

2.0 (0.08) x 4.1 (0.16)

10 (7)

40 (9)

12 (3)

50 (1.97)

25 (0.98)

OFNR

2.9  (0.11) x 5.9 (0.23)

15 (10)

100 (22)   

30 (7)

58 (2.3)

29 (1.1)

OFNP

2.9 (0.11) x 5.9 (0.23)

15 (10)

100 (22)

30 (7)

58 (2.3)

29 (1.1)

Interconnect, 
Dual

2

1 (2)

OFNR

2.9 (0.11)

7 (5)

100 (22)

30 (7)

57 (2.2)

29 (1.1)

OFNP

2.9 (0.11)

9 (6)

100 (22)

30 (7)

57 (2.2)

29 (1.1)

OFNR

4.8 (0.3)

20 (13)

100 (22)

30 (7)

96 (3.8)

48 (1.9)

OFNP

4.8 (0.3)

30 (20)

100 (22)

30 (7)

96 (3.8)

48 (1.9)

Interconnect, 
Quad

4

1 (4)

OFNR

4.8 (0.3)

25 (17)

100 (22)

30 (7)

96 (3.8)

48 (1.9)

OFNP

4.8 (0.3)

30 (20)

100 (22)

30 (7)

96 (3.8)

48 (1.9)

Distribution

6

1 (6)

OFNR

5.2 (0.20)

29 (19)

660 (150)

198 (45)

114 (4.5)

57 (2.2)

OFNP

4.8 (0.19)

24 (16)

440 (100)

132 (30)

110 (4.3)

55 (2.2)

8

1 (8)

OFNR

5.7 (0.22)

24 (16)

660 (150)

198 (45)

136 (5.4)

68 (2.7)

OFNP

5.0 (0.20)

26 (17)

440 (100)

132 (30)

110 (4.3)

55 (2.2)

12

1 (12)

OFNR

6.0 (0.24)

37 (25)

660 (150)

198 (45)

128 (5)

64 (2.5)

OFNP

5.7 (0.23)

46 (31)

440 (100)

132 (30)

128 (5)

64 (2.5)

24

1 (24)

OFNR

8.0 (0.31)

61 (41)

1320 (300) 396 (90)

178 (7)

89 (3.5)

OFNP

7.7 (0.30)

69 (46)

660 (150)

198 (45)

168 (6.6)

84 (3.3)

24

2 (12)

OFNR

7.4 x 13.0 (0.29 x 0.51)

87 (58)

1320 (300) 396 (90)

284 (11.2)

142 (5.6)

OFNP

7.0 x 12.4 (0.28 x 0.49) 92 (62)

660 (150)

198 (45)

264 (10.4)

132 (5.2)

24

4 (6)

OFNR

13.4 (0.53)

180 (121)

1320 (300) 396 (90)

275 (10.8)

137 (5.4)

OFNP

13.3 (0.52)

200 (134)

660 (150)

198 (45)

266 (10.5)

133 (5.2)

36

6 (6)

OFNR

16.4 (0.65)

220 (148)

1320 (300) 396 (90)

342 (13.5)

171 (6.7)

OFNP

16.0 (0.63)

255 (171)

660 (150)

198 (45)

327 (12.9)

164 (6.4)

48

4 (12)

OFNR

16.0 (0.63)

250 (168)

1320 (300) 396 (90)

350 (13.8)

175 (6.9)

OFNP

15.2 (0.60)

202 (136)

660 (150)

198 (45)

312 (12.3)

156 (6.1)

72

6 (12)

OFNR

18.9 (0.75)

301 (202)

1320 (300) 396 (90)

386 (15.2)

193 (7.6)

OFNP

18.5 (0.73)

316 (212)

660 (150)

198 (45)

386 (15.2)

193 (7.6)

96

8 (12)

OFNR

22.8 (0.90)

433 (291)

1320 (300) 396 (90)

462 (18.2)

231 (9.1)

OFNP

22.0 (0.86)

466 (313)

660 (150)

198 (45)

448 (17.6)

224 (8.8)

144

12 (12)

OFNR

24.8 (0.98)

461 (310)

1320 (300) 396 (90)

514 (20.2)

257 (10.1)

OFNP

24.2 (0.95)

474 (319)

660 (150)

198 (45)

514 (20.2)

257 (10.1)

Optical Fiber Cable Technical Information (Continued)

Cable Type

Fiber 

Count

Unit Count

Units  

(Fibers/Unit)

UL/NEC 

Ratings

Diameter  
mm (in)

Weight kg/km  
(lb/kft) 

Tensile Load N (lbf)        

Bending Radius mm (in)

Installation

Long Term Installation Long Term 

Distribution, 
Interlocking 
Armor

6

1 (6)

OFCP

13.1 (0.52)

117 (79)

1335 (300)

400 (90)

197 (7.8)

131 (5.2)

12

1 (12)

OFCP

13.3 (0.52)

129 (87)

1335 (300)

400 (90)

199 (7.8)

133 (5.2)

 24

1 (24)

OFCP

14.8 (0.58)

176 (119)

1780 (400)

534 (120)

223 (8.8)

148 (5.8)

24

2(12)

OFCP

18.9 (0.74)

240 (161)

1780 (400)

534 (120)

192 (7.6)

128 (5.0)

48

4 (12)

OFCP

23.4 (0.92)

408 (274)

2640 (600)

800 (180)

351 (13.8)

234 (9.2)

72

6 (12)

OFCP

24.7 (0.97)

537 (361)

2640 (600)

800 (180)

371 (14.6)

247 (9.7)

Indoor/
Outdoor, 
Single Loose 
Tube

6

1 (6)

OFNR

6.5 (0.26)

45 (30)

1335 (300)

400 (90)

97 (3.8)

65 (2.6)

OFNP

6.6 (0.26)

45 (30)

1335 (300)

400 (90)

99 (3.9)

66 (2.6)

8

 1 (8)

OFNR

6.5 (0.26)

45 (30)

1335 (300)

400 (90)

97 (3.8)

65 (2.6)

OFNP

6.6 (0.26)

46 (31)

1335 (300)

400 (90)

99 (3.9)

66 (2.6)

12

1 (12)

OFNR

6.5 (0.26)

45 (30)

1335 (300)

400 (90)

97 (3.8)

65 (2.6)

OFNP

6.6 (0.26)

46 (31)

1335 (300)

400 (90)

99 (3.9)

66 (2.6)

Indoor/
Outdoor, 
Stranded 
Loose Tube

24

2 (12)

OFNR

10.1 (0.40)

84 (56)

2670 (600)

890 (200)

151 (5.9)

101 (4.0)

OFNP

9.7 (0.38)

86 (58)

2670 (600)

890 (200)

145 (5.7)

97 (3.8)

36

 3 (12)

OFNR

10.1 (0.40)

84 (56)

2670 (600)

890 (200)

151 (5.9)

101 (4.0)

OFNP

9.7 (0.38)

86 (58)

2670 (600)

890 (200)

145 (5.7)

97 (3.8)

48

4 (12)

OFNR

10.1 (0.40)

84 (56)

2670 (600)

890 (200)

151 (5.9)

101 (4.0)

OFNP

9.7 (0.38)

86 (58)

2670 (600)

890 (200)

145 (5.7)

97 (3.8)

 72

6 (12)

OFNR

11.9 (0.47)

111 (75)

2670 (600)

890 (200)

178 (7.0)

119 (4.7)

OFNP

11.7 (0.46)

101 (68)

2670 (600)

890 (200)

175 (6.9)

117 (4.6)

96

 8 (12)

OFNR

13.7 (0.54)

147 (99)

2670 (600)

890 (200)

206 (8.1)

137 (5.4)

OFNP

13.5 (0.53)

175 (118)

2670 (600)

890 (200)

203 (8.0)

135 (5.3)

144

12 (12)

OFNR

17.8 (0.70)

252 (169)

4448 (1000)

1335 (300)

267 (10.5)

178 (7.0)

OFNP

17.7 (0.70)

300 (202)

4448 (1000)

1335 (300)

255 (10.1)

170 (6.7)

Sc1_Fiber_02_CablesConnectors_v1.indd   33

12/11/12   3:56 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-34

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Figure A

Figure E

Figure D

Figure B

Figure C

ORDERING INFORMATION

Multimode LightCrimp PLUS Connectors
(No epoxy/No polish) 

• 

Easy installation:

No epoxy, no polishing

No bench tool required

Strip, cleave, and crimp

• 

Match fi ber type of cable to boot color of LightCrimp PLUS

• 

Mates with standard couplers, adapters, and adapter plates

• 

LC small form factor design is half the size of SC

• 

Select appropriate part number for termination to:

900

µ

m tight-buff ered fi ber or 250

µ

m coated fi ber

2.0 mm jacketed fi ber

3 mm jacketed fi ber

• 

LC connector clip turns simplex connectors into duplex
connectors and allows for polarity correction after termination

• 

LC-SECURE LightCrimp PLUS Simplex Connectors
can be found in the SECURE Network Solutions
Fiber Products in section 2 of the catalog

OM3 and OM4 (50/125

µ

m) Multimode LightCrimp PLUS

Connectors (No epoxy/No polish)

Connector Type

Housing Color Boot Color

Used With

Figure Part Number

LC Simplex

Beige

Aqua

900 

µ

m buff ered

and 250 

µ

m coated fi bers

A

6754483-4

2.0 mm jacketed cable

1918627-3

SC Simplex

Beige

Aqua

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

B

6588291-2

ST

Metallic

Aqua

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

C

6278082-2

Duplex LC Clip, package of 6

Black

Simplex LC connectors

D

1754371-2

1/2 Duplex SC Clip

two are required to make a complete clip

Black

Simplex SC connectors

E

6348522-1

Sc1_Fiber_02_CablesConnectors_v1.indd   34

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-35

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Connector Type

Housing Color Boot Color

Used With

Figure Part Number

LC Simplex

Beige

Aqua

900 

µ

m buff ered

and 250 

µ

m coated fi bers

A

6754483-4

2.0 mm jacketed cable

1918627-3

SC Simplex

Beige

Aqua

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

B

6588291-2

ST

Metallic

Aqua

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

C

6278082-2

Duplex LC Clip, package of 6

Black

Simplex LC connectors

D

1754371-2

1/2 Duplex SC Clip

two are required to make a complete clip

Black

Simplex SC connectors

E

6348522-1

50/125

µ

m OM2 Multimode LightCrimp PLUS

Connectors (No epoxy/No polish) 

ORDERING INFORMATION

Connector Type

Housing Color

Boot Color

Used With

Figure

Part Number

LC Simplex

Beige

Black

900 

µ

m buff ered

and 250 

µ

m coated fi bers

A

6754483-2

2.0 mm jacketed cable

1918627-2

SC Simplex

Beige

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

B

6278079-2

ST

Metallic

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

C

6278082-1

Duplex LC Clip, package of 6

Black

Simplex LC connectors

D

1754371-2

1

/

2

 Duplex SC Clip

two are required to make a complete clip

Black

Simplex SC connectors

E

6348522-1

Figure E

Figure D

Figure A

Figure B

Figure C

Sc1_Fiber_02_CablesConnectors_v1.indd   35

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-36

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

62.5/125

µ

m OM1 Multimode LightCrimp PLUS

Connectors (No epoxy/No polish) 

ORDERING INFORMATION

Connector Type

Housing Color

Boot Color

Used With

Figure

Part Number

LC Simplex

Beige

Beige

900 

µ

m buff ered

and 250 

µ

m coated fi bers

A

6754483-1

2.0 mm jacketed cable

1918627-1

SC Simplex

Beige

Beige

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

B

5492643-1

ST

Metallic

Beige

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

C

5492642-2

Duplex LC Clip, 

package of 6

Beige

Simplex LC connectors

D

1754371-5

1/2 Duplex SC Clip

two are required to make a complete clip

Beige

Simplex SC connectors

E

6348522-4

Figure B

Figure E

Figure D

Figure A

Figure C

Sc1_Fiber_02_CablesConnectors_v1.indd   36

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-37

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Connector Type

Housing Color

Boot Color

Used With

Figure

Part Number

LC Simplex

Beige

Beige

900 

µ

m buff ered

and 250 

µ

m coated fi bers

A

6754483-1

2.0 mm jacketed cable

1918627-1

SC Simplex

Beige

Beige

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

B

5492643-1

ST

Metallic

Beige

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

C

5492642-2

Duplex LC Clip, 

package of 6

Beige

Simplex LC connectors

D

1754371-5

1/2 Duplex SC Clip

two are required to make a complete clip

Beige

Simplex SC connectors

E

6348522-4

Figure C

Singlemode LightCrimp PLUS Connectors
(No epoxy/No polish)

ORDERING INFORMATION

Connector Type

Housing Color

Boot Color

Used With

Figure

Part Number

LC Simplex, APC

Green

Blue

900 

µ

m buff ered

and 250 

µ

m coated fi bers

2064181-1

LC Simplex

Blue

Blue

900 

µ

m buff ered

and 250 

µ

m coated fi bers

A

6754482-1

2.0 mm jacketed cable

1918626-1

SC Simplex, APC

Green

Blue

900 

µ

m buff ered

and 250 

µ

m coated fi bers

2064184-1

SC Simplex

Blue

Blue

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

B

6693276-1

ST

Metallic

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

C

1828953-3

Duplex LC Clip, package of 6

Blue

Simplex LC connectors

D

1754371-4

1

/

2

 Duplex SC Clip

two are required to make a complete clip

Blue

Simplex SC connectors

E

6348522-3

Note: APC (Angle Polish Connector) connectors are for use with other APC products.

Figure B

Figure E

Figure D

Figure A

Sc1_Fiber_02_CablesConnectors_v1.indd   37

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-38

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

ORDERING INFORMATION

LightCrimp Splice

• 

Terminates 250

µ

m coated, 900

µ

m tight-buff ered, and 2.0 mm

jacketed fi bers

• 

Use with multimode and single-mode 125

µ

m diameter fi bers

• 

No epoxy, set-up, or workstation required

• 

Use Termination Tool Kit part number 1553212-1

• 

Splice Performance Characteristics:

Attenuation: Typical 0.1 dB

Return Loss: (at ambient: 18 to 28° C)
>40 dB Multimode
>60 dB Singele-mode

Operating Temperature:
 -25 to 70° C

• 

Tensile Retention:

250

µ

m coated: 2.0 N

900

µ

m buff ered: 3.0 N

Jacketed: 50 N

Description

Figure

Part Number

LightCrimp Splice for 250 

µ

m Coated and 900 

µ

m tight-buff ered Fibers

A

1985374-1

LightCrimp Splice for 2.0 mm Jacketed Fiber

B

1985805-1

Insert First Fiber 

and Complete 

Buff er Crimp

Insert Second 

Fiber and 

Actuate Crimp

Complete Second Buff er 

Crimp and Remove 

Splice from Tool

Figure A

Figure B

Sc1_Fiber_02_CablesConnectors_v1.indd   38

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-39

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Description

Figure

Part Number

LightCrimp Splice for 250 

µ

m Coated and 900 

µ

m tight-buff ered Fibers

A

1985374-1

LightCrimp Splice for 2.0 mm Jacketed Fiber

B

1985805-1

• 

Each connector kit comes with accessories needed
to terminate to 250

µ

m fi ber, 900

µ

m tight-buff ered

fi ber, 900

µ

m easy-strip, buff er tube splitter kits, 2 mm

or 3 mm cable (select appropriate part number)

• 

Suitable for use with heat-cured or
anaerobic (quick cure) adhesive

• 

See instruction sheet for recommended anaerobic adhesive

• 

Mates with standard couplers, adapters, and adapter plates

• 

LC small form factor design is half the size of SC

• 

Pre-radiused ceramic ferrules for easy polishing

• 

Duplex SC can be assembled using two simplex
SC connectors and one duplex clip

• 

Boot type and coupling nut options
(select appropriate part number)

Description

Housing Color Boot Color

Used With

Figure

Part Number

LC Simplex

Beige

Aqua

900

 µ

m buffered and

250 

µ

m coated fibers

A

1918385-3

2 mm jacketed cable

B

1918267-3

3.0 mm jacketed cable

C

1918375-3

Duplex LC Clip, package of 6

Black

Simplex LC connectors

D

1754371-2

SC Simplex

Beige

Aqua

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

E

1-5503948-1

3 mm jacketed cable

1-5503948-0

900 

µ

m buff ered and

250 

µ

m coated fi bers

E

5504932-5

2 mm jacketed cable

5504931-5

1/2

 Duplex SC Clip

two are required to make a complete clip

Black

Simplex SC connectors

F

6348522-1

ST

Black

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

5503571-3

Metallic

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

G

5492458-1

3 mm jacketed cable

1-5501380-6

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

G

5501380-1

Figure E

Figure G

Figure D

Figure F

Figure C

Figure A

Figure B

ORDERING INFORMATION

Multimode Epoxy/Polish Connectors

OM3 and OM4 Multimode Epoxy/Polish Connectors

Sc1_Fiber_02_CablesConnectors_v1.indd   39

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-40

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

50/125

µ

m OM2 Multimode Epoxy/Polish Connectors

Figure G

Figure D

Figure F

Description

Housing Color

Boot Color

Used With

Figure

Part Number

LC Simplex

Beige

Black

900

 µ

m buffered and

250 

µ

m coated fibers

A

1918385-4

2 mm Jacketed Cable

B

1918267-4

3.0 mm Jacketed Cable

C

1918375-4

Duplex LC Clip, package of 6

Black

Simplex LC Connectors

D

1754371-2

SC Simplex

Beige

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm Jacketed Cable

E

1-5503948-3

3 mm Jacketed Cable

1-5503948-2

900 

µ

m buff ered and

250 

µ

m coated fi bers

E

5504932-1

2 mm Jacketed Cable

5504931-6

1

/

2

 Duplex SC Clip

two are required to make a complete clip

Black

Simplex SC Connectors

F

6348522-1

ST

Black

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm Jacketed Cable

5503571-3

Metallic

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm Jacketed Cable

G

5492458-1

3 mm Jacketed Cable

1-5501380-6

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm Jacketed Cable

G

5501380-1

 

 

ORDERING INFORMATION

Figure B

Figure C

Figure A

Figure E

Sc1_Fiber_02_CablesConnectors_v1.indd   40

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-41

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Description

Housing Color

Boot Color

Used With

Figure

Part Number

LC Simplex

Beige

Black

900

 µ

m buffered and

250 

µ

m coated fibers

A

1918385-4

2 mm Jacketed Cable

B

1918267-4

3.0 mm Jacketed Cable

C

1918375-4

Duplex LC Clip, package of 6

Black

Simplex LC Connectors

D

1754371-2

SC Simplex

Beige

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm Jacketed Cable

E

1-5503948-3

3 mm Jacketed Cable

1-5503948-2

900 

µ

m buff ered and

250 

µ

m coated fi bers

E

5504932-1

2 mm Jacketed Cable

5504931-6

1

/

2

 Duplex SC Clip

two are required to make a complete clip

Black

Simplex SC Connectors

F

6348522-1

ST

Black

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm Jacketed Cable

5503571-3

Metallic

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm Jacketed Cable

G

5492458-1

3 mm Jacketed Cable

1-5501380-6

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm Jacketed Cable

G

5501380-1

62.5/125

µ

m OM1 Multimode Epoxy/Polish Connectors

Description

Housing Color

Boot Color

Used With

Figure

Part Number

LC Simplex

Beige

Beige

900

 µ

m buffered and

250 

µ

m coated fibers

A

1918385-1

2 mm jacketed cable

B

1918267-1

3.0 mm jacketed cable

C

1918375-1

Duplex LC Clip, package of 6

Beige

Simplex LC connectors

D

1754371-5

SC Simplex

Beige

Beige

900 

µ

m buff ered fi bers,

and

3 mm jacketed cable

E

5503948-5

3 mm jacketed cable

5503948-1

900 

µ

m buff ered and

250 

µ

m coated fi bers

E

5504932-6

2 mm jacketed cable

5504931-1

1

/

2

 Duplex SC Clip

two are required to make a complete clip

Beige

Simplex SC connectors

F

6348522-4

ST

Black

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

5503571-3

Metallic

Black

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

G

5492458-1

3 mm jacketed cable

1-5501380-6

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

G

5501380-1

 

 

ORDERING INFORMATION

Figure D

Figure F

Figure C

Figure A

Figure B

Figure E

Figure G

Sc1_Fiber_02_CablesConnectors_v1.indd   41

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-42

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Singlemode Epoxy/Polish Connectors

Description

Housing Color

Boot Color

Used With

Figure

Part Number

LC Simplex

Blue

Blue

900

 µ

m buffered and

250 

µ

m coated fibers

A

1918384-1

1.6 to 2 mm jacketed cable

B

1918266-1

3.0 mm jacketed cable

C

1918374-1

Duplex LC Clip, package of 6

Blue

Simplex LC connectors

D

1754371-4

SC Simplex

Blue

Blue

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

E

5504646-7

3 mm jacketed cable

5504646-1

900 

µ

m buff ered and

250 

µ

m coated fi bers

E

5492123-1

2 mm jacketed cable

5504934-2

SC Duplex

Blue

Blue

2 mm jacketed cable

5504655-1

1

/

2

 Duplex SC Clip

two are required to make a complete clip

Blue

Simplex SC connectors

F

6348522-3

ST

Metallic

Yellow

900 

µ

m buff ered fi bers and

3 mm jacketed cable

5503613-2

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

G

5502579-2

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable, short boot 

G

5502580-2

 

 

ORDERING INFORMATION

Figure D

Figure F

Figure C

Figure A

Figure B

Figure E

Figure G

Sc1_Fiber_02_CablesConnectors_v1.indd   42

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-43

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Description

Housing Color

Boot Color

Used With

Figure

Part Number

LC Simplex

Blue

Blue

900

 µ

m buffered and

250 

µ

m coated fibers

A

1918384-1

1.6 to 2 mm jacketed cable

B

1918266-1

3.0 mm jacketed cable

C

1918374-1

Duplex LC Clip, package of 6

Blue

Simplex LC connectors

D

1754371-4

SC Simplex

Blue

Blue

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

E

5504646-7

3 mm jacketed cable

5504646-1

900 

µ

m buff ered and

250 

µ

m coated fi bers

E

5492123-1

2 mm jacketed cable

5504934-2

SC Duplex

Blue

Blue

2 mm jacketed cable

5504655-1

1

/

2

 Duplex SC Clip

two are required to make a complete clip

Blue

Simplex SC connectors

F

6348522-3

ST

Metallic

Yellow

900 

µ

m buff ered fi bers and

3 mm jacketed cable

5503613-2

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable

G

5502579-2

900 

µ

m buff ered fi bers,

250 

µ

m coated fi bers, and

3 mm jacketed cable, short boot 

G

5502580-2

ORDERING INFORMATION

Multimode MT-RJ Jacks
(No epoxy/No polish) 

• 

Patch panel jacks terminate either two 900 

µ

m

tight-buff ered fi bers or two 250

µ

m coated

fi bers (select appropriate part number)

• 

Outlet jacks terminate two 900

µ

m tight-buff ered fi bers

• 

Match fi ber type of cable to fi ber type of MT-RJ Jack

• 

No epoxy, no polishing, no crimping

• 

Two fi bers in one ferrule

• 

Jacks can be reterminated improving yield

• 

Tunable

• 

No bench tool required

• 

Small form factor design is half the size of SC duplex

• 

Jack design eliminates need for MT-RJ coupler

• 

Each outlet jack part number includes:

One MT-RJ jack

One actuation tool

One bend-limiting boot

One SL series housing – allows use in any faceplate
or outlet that accepts SL series jacks

• 

Each patch panel jack part number includes:

Six patch panel jacks

Two actuation tools

One fi ber guide

One icon wheel

• 

SL series housing and bend limiting boot
are also available separately

OM3 and OM4 Multimode MT-RJ Jacks (No epoxy/No polish)

Strip

Cleave

Lock

Description

Jack Color

SL Series Housing Color

For Use With

900 

µ

m Tight-Buff ered Fibers 250 

µ

m Coated Fibers 

MT-RJ Patch Panel Jack

Gray

6588880-3

   6278303-4

MT-RJ Outlet Jack

Gray

Gray

1-6278414-2

          –

MT-RJ

Outlet Jack

MT-RJ Patch Panel Jacks

SL Series 

Housing (Gray)

Sc1_Fiber_02_CablesConnectors_v1.indd   43

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-44

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

50/125

µ

m OM2 Multimode MT-RJ Jacks

(No epoxy/No polish) 

MT-RJ 

Outlet Jack

SL Series Housing 

(Almond)

ORDERING INFORMATION

Descirption

Jack Color

SL Series Housing Color

For Use With

900 

µ

m Tight-buffered Fibers

250 

µ

m Coated Fibers 

MT-RJ Patch Panel Jack

Black

6588880-1

6278303-1

MT-RJ Outlet Jack

Black

Almond

6278414-1

Black

6278414-2

White

6278414-3

Gray

6278414-4

Orange

6278414-5

Blue

6278414-6

Red

6278414-7

Yellow

6278414-8

Green

6278414-9

Violet

1-6278414-0

Electrical Ivory

1-6278414-1

MT-RJ Patch Panel Jacks

Sc1_Fiber_02_CablesConnectors_v1.indd   44

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-45

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Descirption

Jack Color

SL Series Housing Color

For Use With

900 

µ

m Tight-buffered Fibers

250 

µ

m Coated Fibers 

MT-RJ Patch Panel Jack

Black

6588880-1

6278303-1

MT-RJ Outlet Jack

Black

Almond

6278414-1

Black

6278414-2

White

6278414-3

Gray

6278414-4

Orange

6278414-5

Blue

6278414-6

Red

6278414-7

Yellow

6278414-8

Green

6278414-9

Violet

1-6278414-0

Electrical Ivory

1-6278414-1

ORDERING INFORMATION

62.5/125 m OM1 Multimode MT-RJ Jacks
(No epoxy/No polish) 

Descirption

Jack Color

SL Series Housing Color

For Use With

900 m Tight-buffered Fibers

250 m Coated Fibers 

MT-RJ Patch Panel Jack

Beige

6588880-2

6278303-2

MT-RJ Outlet Jack

Beige

Almond

6278415-1

Black

6278415-2

White

6278415-3

Gray

6278415-4

Orange

6278415-5

Blue

6278415-6

Red

6278415-7

Yellow

6278415-8

Green

6278415-9

Violet

1-6278415-0

Electrical Ivory

1-6278415-1

MT-RJ 

Outlet Jack

SL Series 

Housing

MT-RJ Patch Panel Jacks

Sc1_Fiber_02_CablesConnectors_v1.indd   45

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-46

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Description

Package Quantity

Figure

SL Series Housing Color

Part Number

Parallel Dress Clip

1-Port (Accepts 1 MT-RJ Jack)

6

A

1374206-1

2-Port (Accepts 2 MT-RJ Jacks)

3

B

1374205-1

Bend Limiting Boot

Black

6

C

6374208-4

Beige

6

6374208-5

SL Series Housing

1-Port (Accepts 1 MT-RJ Jack)

1

D

Almond

1374416-1

Black

1374416-2

White

1374416-3

Gray

1374416-4

Orange

1374416-5

Blue

1374416-6

Red

1374416-7

Yellow

1374416-8

Green

1374416-9

Violet

1-1374416-0

Electrical Ivory

1-1374416-1

Rose

2-1374416-3

Aqua

2-1374416-4

Brown

2-1374416-5

Slate

2-1374416-6

Multimode MT-RJ Jack Accessories
(OM4, OM3, OM2, and OM1)

• 

Parallel dress clips:

1-Port clip holds one MT-RJ Jack (sold separately)

2-Port clip holds two MT-RJ Jacks (sold separately)

Allow use of MT-RJ jacks in faceplates and outlets
that hold fl anged optical fi ber adapters

Can be used with HIDEAWAY and HIDEOUT outlets

• 

Bend limiting boots:

Compatible with all MT-RJ Jacks

Comes in a package of six

Protects fi ber transition at back of MT-RJ jack

• 

SL Series housing easily snap into SL series modules,
mounting straps, patch panels, and faceplates

• 

SL series housing accepts one MT-RJ jack sold separately

• 

MT-RJ outlet jacks not included with any accessory listed here

ORDERING INFORMATION

Figure A

Figure C

Figure B

Figure D

Figure E

Sc1_Fiber_02_CablesConnectors_v1.indd   46

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-47

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Multimode Snap-in Adapter Plates

• 

All snap-in adapter plates fi t RMG
unloaded optical fi ber enclosures

• 

MT-RJ jack adapter plates:

Hold up to six (6) MT-RJ (standard or secure)
jacks or pigtail jack cable assemblies

Accepts labeling icons

• 

MT-RJ plug adapter plates hold up to twelve (12)
MT-RJ plugs (standard only)

• 

Package quantity = 1 per pack

• 

SL Series multimedia adapter plates
accept SL series jacks and inserts

OM3 and OM4 (50/125

µ

m) Multimode Snap-in Adapter Plates

Figure C

Figure F

Figure I

Figure L 

Figure B

Figure E

Figure H

Figure K

Figure A

Figure D

Figure G

Figure J

Coupling Adapter

Fibers

Duplex Ports

Coupler Count

Adapter Color

Figure

Part Number

LC Duplex

12

6

6

Aqua

A

1374463-5

24

12

12

Aqua

B

1435516-5

MT-RJ, Holds 6 Jacks

12

6

C

1278328-3

MT-RJ, 12 Plugs

24

12

Black

D

1435440-2

SC Simplex

6

3

3

Aqua

559517-8

SC Duplex

6

3

3

Aqua

E

559558-6

12

6

6

Aqua

F

559596-6

SC Duplex to Dual ST

6

3

3

Aqua

G

559601-5

12

6

6

Aqua

H

1278368-3

ST

6

3

6

Metallic

I

559557-1

12

6

6

Beige

J

1278567-1

MPO

6

Black

1374598-1

Blank

K

559523-1

SL Series Multimedia Adapter Plate

L

1479506-1

ORDERING INFORMATION

Sc1_Fiber_02_CablesConnectors_v1.indd   47

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-48

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

50/125

µ

m OM2 Multimode Snap-in Adapter Plates

Figure C

Figure I

Figure L 

Figure B

Figure H

Figure K

Figure A

Figure D

Figure G

Figure J

Coupling Adapter

Fibers

Duplex Ports

Coupler Count

Adapter Color

Figure

Part Number

LC Duplex

12

6

6

Black

A

1374463-4

24

12

12

Black

B

1435516-4

MT-RJ, Holds 6 Jacks

12

6

C

1278328-3

MT-RJ, 12 Plugs

24

12

Black

D

1435440-2

SC Simplex

6

3

3

Black

559517-3

SC Duplex

6

3

3

Black

E

559558-5

12

6

6

Black

F

559596-5

SC Duplex to Dual ST

6

3

3

Black

G

559601-4

12

6

6

Black

H

1278368-2

ST

6

3

6

Metallic

I

559557-1

12

6

6

Beige

J

1278567-1

MPO

6

Black

1374598-1

Blank

K

559523-1

SL Series Multimedia Adapter Plate

L

1479506-1

ORDERING INFORMATION

Figure E

Figure F

Sc1_Fiber_02_CablesConnectors_v1.indd   48

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-49

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Coupling Adapter

Fibers

Duplex Ports

Coupler Count

Adapter Color

Figure

Part Number

LC Duplex

12

6

6

Black

A

1374463-4

24

12

12

Black

B

1435516-4

MT-RJ, Holds 6 Jacks

12

6

C

1278328-3

MT-RJ, 12 Plugs

24

12

Black

D

1435440-2

SC Simplex

6

3

3

Black

559517-3

SC Duplex

6

3

3

Black

E

559558-5

12

6

6

Black

F

559596-5

SC Duplex to Dual ST

6

3

3

Black

G

559601-4

12

6

6

Black

H

1278368-2

ST

6

3

6

Metallic

I

559557-1

12

6

6

Beige

J

1278567-1

MPO

6

Black

1374598-1

Blank

K

559523-1

SL Series Multimedia Adapter Plate

L

1479506-1

62.5/125

µ

m OM1 Multimode Snap-in Adapter Plates

Coupling Adapter

Fibers

Duplex Ports

Coupler Count

Adapter Color

Figure

Part Number

LC Duplex

12

6

6

Beige

A

1374463-2

24

12

12

Beige

B

1435516-2

MT-RJ, Holds 6 Jacks

12

6

C

1278328-3

MT-RJ, 12 Plugs

24

12

Beige

D

1435440-1

SC Simplex

6

3

3

Beige

559517-7

SC Duplex

6

3

3

Beige

E

559558-1

12

6

6

Beige

F

559596-1

SC Duplex to Dual ST

6

3

3

Beige

G

559601-1

12

6

6

Beige

H

1278368-1

ST

6

3

6

Metallic

I

559557-1

12

6

6

Beige

J

1278567-1

MPO

6

Black

1374598-1

Blank

K

559523-1

SL Series Multimedia Adapter Plate

L

1479506-1

ORDERING INFORMATION

Figure H

Figure I

Figure C

Figure A

Figure B

Figure L

Figure F

Figure D

Figure E

Figure G

Figure J

Figure K

Sc1_Fiber_02_CablesConnectors_v1.indd   49

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-50

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Singlemode Snap-in Adapter Plates

Coupling Adapter

Fibers

Duplex Ports

Coupler Count

Adapter Color

Figure

Part Number

LC Duplex

12

6

6

Blue

A

1374463-1

24

12

12

Blue

B

1435516-1

LC Duplex, APC

12

6

6

Green

1374463-6

24

12

12

Green

1435516-6

MT-RJ, Holds 6 Jacks

12

6

C

1278328-3

MT-RJ, 12 Plugs

24

12

Blue

D

1435440-3

SC Simplex

6

3

3

Blue

559517-1

SC Simplex, APC

6

3

3

Green

559517-2

SC Duplex

6

3

3

Blue

E

559558-2

12

6

6

Blue

F

559596-2

SC Duplex, APC

6

3

3

Green

559558-7

12

6

6

Green

559596-3

SC Duplex to Dual ST

6

3

3

Blue

G

559601-6

12

6

6

Blue

H

1278368-5

ST

6

3

6

Metallic

I

559515-2

12

6

6

Blue

J

1278567-2

MPO

6

Black

1374598-1

Blank

K

559523-1

SL Series Multimedia Adapter Plate

L

1479506-1

Note: APC (Angle Polish Connector) connectors are for use with other APC products.

Figure C

Figure F

Figure I

Figure L 

Figure B

Figure E

Figure H

Figure K

Figure A

Figure G

Figure J

ORDERING INFORMATION

Figure D

Sc1_Fiber_02_CablesConnectors_v1.indd   50

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-51

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Figure A

Figure C

Figure D

Figure B

ORDERING INFORMATION

Multimode Couplers and Adapters

• 

MT-RJ couplers mate multimode or singlemode MT-RJ plugs

• 

Duplex coupler mates four MT-RJ plugs (4-fi bers total, 2-fi bers/mated pair)

• 

Simplex coupler mates two MT-RJ plugs (2-fi bers total, 2-fi bers/mated pair)

• 

Mounting screws are available for couplers with mounting tabs (fl anged)

• 

FOCIS – compliant designs

OM3 and OM4 Multimode Couplers and Adapters

Part Number

Description

Color

Figure

Simplex

Duplex

MT-RJ Coupler

Almond

1278017-1

6374906-1

SC Coupler

Aqua

A

2-5502632-4

2-5502776-6

SC to ST Coupling Adapter

Aqua

B

2-5502780-1

1-5503137-9

ST Coupler

Metallic/Beige

C

501381-1

504662-2

LC Coupler

Aqua

D

1-6457567-6

Simplex

Simplex

Simplex

Duplex

Dual

Duplex

Duplex

Sc1_Fiber_02_CablesConnectors_v1.indd   51

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Cables and Field Terminated Connectors

1-52

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Figure A

Figure C

Figure D

Figure B

ORDERING INFORMATION

62.5/125

µ

m OM1 Multimode Couplers and Adapters

Description

Color

Figure Simplex

Duplex

MT-RJ Coupler

Almond

 1278017-1

 6374906-1

SC Coupler

Beige

A

 5504614-1

 5504640-1

SC to ST Coupling Adapter

Beige

B

 5502780-3

 5504663-4

ST Coupler

Metallic/Beige

C

 501381-1

 504662-2

LC Coupler

Beige

D

 6457567-5

Simplex

Simplex

Simplex

Duplex

Dual

Duplex

Duplex

Singlemode Couplers and Adapters

ORDERING INFORMATION

Part Number

Description

Color

Figure

Simplex

Duplex

Quadplex 
(Dual Duplex)

MT-RJ Coupler

Almond

 1278017-1

 6374906-1

LC Coupler

Blue

A

 1457062-1

 6457567-4

 1695790-4

SC Coupler

Blue

B

 5502632-8

 1-5502776-1

SC to ST Coupling Adapter

Blue

C

 5502780-2

 5503137-5

ST Coupler

Metallic/Blue

D

 504021-1

 503273-5

Simplex

Figure B

Duplex

Figure C

Simplex

Duplex

Figure A

Duplex

Figure D

Simplex

Dual

Sc1_Fiber_02_CablesConnectors_v1.indd   52

12/11/12   3:57 PM

Tyco-catalog-AMP-2013-html.html
background image

1-53

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber

Fiber Enclosures

Fiber Enclosures – Q3000

Q3000 Series Fiber Panels are the latest innovation in the Quareo suite of products. The 
Q3000 Series fi ber enclosure supports applications with high density fi ber terminations through 
simplifi ed access to individual connectors, combined with enhanced cable management features. 
The Q3000 series accommodates singlemode and multimode LC and MPO connectivity. Q3000 
panels are compatible with the Quareo Cross-Connect Frame to provide enhanced density in an 
accessible yet highly-managed system.

FEATURES

• 

Support IEEE 802.3ae, IEEE 802.3ba, IEEE 802.3z

• 

Exceed ANSI/TIA-568-C.3 and ISO 11801 Edition 2 cabling system requirements

• 

OM3/OM4 and OS2

• 

19-Inch rack mountable

• 

Available in 1, 2, and 4RU chassis

• 

48-fi ber (24 Duplex LC) LC-to-LC or LC-to-MPO blade

• 

192-fi ber (16 MPO Ports) MPO-to-MPO blade

Product Description

Part Number

Q3000 series chassis

Q3200; 1RU (1.75" x 19" x 15"), accommodates 2 blades

 QUCH-1RU

Q3400; 2RU (3.5" x 19" x 15"), accommodates 4 blades

 QUCH-2RU

Q3800; 4RU (7" x 19" x 15"), accommodates 8 blades

 QUCH-4RU

Front door kits

Q3200; 1RU

 QDR-1RU

Q3400; 2RU

 QDR-2RU

Q3800; 4RU

 QDR-4RU

Blank blade cover

For covering unused slots in Q3000 or Q4000 chassis

 QBCB-HR

ORDERING INFORMATION

RMG

•   Low Feature – 

Competitive price

•   Modular solution 

(Industry LGX footprint)

•   Single chassis for all applications

TFP

•   Medium Feature – 

Lower density for better 
connector access

•   Modular solution 

(Unique TE footprint)

•   Single chassis for all applications

Q3000

•   Highest Feature – 

Highest manageable density

•   Uses blades as user interface

•   Addresses termination/MPO 

applications in same chassis

Fiber Enclosure Comparison

LOW 

FEATURE

HIGH 

FEATURE

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   53

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Q3000

1-54

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

LC-LC Blade

LC-MPO Blade

MPO-MPO  Blade

Product Description

Part Number

LC to LC; 24 Port Duplex 
LC (48-fiber), LC-to-LC

OM3/OM4 Multimode LC-LC blade

QUFB-48FDLCLMMHR

Singlemode LC-LC blade

QUFB-48FDLCLSMHR

LC to MPO; 24 Duplex 
LC ports (48-fibers)
distributed from 2 each 12 
fiber MPO connectors

OM3/OM4 Multimode LC-MPO elite blade
Multimode (OM3/OM4) Loss (<0.5 dB) @ 850 nm/1300 nm

QUFB-48FDLCMM3HR

Singlemode ultra polish LC-MPO elite blade
Singlemode Loss (<0.75 dB) @ 1310 nm/1550 nm

QUFB-48FDLCMSMHR

MPO to MPO; 16 MPO 
ports with 12-fibers each

OM3/OM4 Multimode MPO-MPO elite blade

QUFB-192FMPOMMHR

Singlemode MPO-MPO blade

QUFB-192FMPOSMHR

ORDERING INFORMATION

Q3000 Blades

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   54

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - RMG

1-55

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Enclosures – RMG Series Fiber Enclosures

TE introduces the RMG series of rack mount fiber enclosures as an integral 
part of the TE's product portfolio. The RMG series fiber enclosure provides 
rugged and durable protection for patching or splicing of fiber cables. 
Especially designed to be user friendly, the slide-out design and removable 
front and rear panels provide convenient access points.

TE's RMG series offers a cost effective and high-density rack mount fiber 
enclosure in one, two and four rack unit sizes. Its modular design and flexible 
configurations make it very user friendly and easy to install.

FEATURES

• 

1RU and 2RU units contain sliding and removable front and rear access 
panels, providing convenient access points

• 

Designed for 48.26 cm (19 inch) EIA rack or cabinet environment; optional 
brackets to accommodate 58.42 cm (23 inch) rack or cabinet mounting

• 

Density: up to 72 terminations in 1RU

• 

Low profile design with higher density for space limited applications

• 

User friendly design utilizing industry standard LSX/LGX modular 
adapter packs

• 

Side and rear cable entry points on back of panel supports a wide range 
of deployment applications

Description

Panel Height

Part Number

Rack or Cabinet Mount Panel, black

  1RU empty panel; accommodates 3 modular adapter packs; black

4.45 cm (1.75")

RMG-1000-000B

  2RU empty panel; accommodates 6 modular adapter packs; black

8.89 cm (3.50")

RMG-2000-000B

   4RU empty panel; accommodates 12 adapter packs;  

also includes cable management bracket and cable clamp; black

17.78 cm (7.00")

RMG-4000-000B

Accessories

  Cable Clamp Kit (for 1RU and 2RU)

RMG-ACC001

  Blank Plates

RMG-00ADP00

Splice Tray

  Heat shrink fusion

FST-DV-HS

  Mechanical

FST-DV-MT

Extender Brackets; 48.26 cm (19" - 23")

  1RU

EB-17B

  2RU

EB-35B

  Q-Frame 4RU Mounting Bracket

RMG-ACCQBRKT4RU

ORDERING INFORMATION

RMG Empty Panels

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   55

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - RMG

1-56

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Description

 Part Number

OM1/OM2 Multimode adapter only packs

 

LC quad adapters, beige color 

 

6 adapters or 24 fiber ports per adapter pack

RMG-24ADPQ3

 

LC adapters, beige color 

 

6 adapters or 12 fiber ports per adapter pack

RMG-12ADPQ1

 

SC duplex adapters, beige color 

 

6 adapters or 12 fiber ports per adapter pack

RMG-12ADPC3

 

SC adapters, beige color 

 

6 adapters or 6 fiber ports per adapter pack

RMG-06ADPC1

 

ST adapters  

 

6 adapters or 6 fiber ports per adapter pack

RMG-06ADPT1

OM3/OM4 multimode adapter only packs

1

 

LC quad adapters, aqua color 

 

6 adapters or 24 fiber ports per adapter pack

RMG-24ADPQ4

 

LC adapters, aqua color 

 

6 adapters or 12 fiber ports per adapter pack

RMG-12ADPQ2

 

SC duplex adapters, aqua color 

 

6 adapters or 12 fiber ports per adapter pack

RMG-12ADPC4

 

SC adapters, aqua color 

 

6 adapters or 6 fiber ports per adapter pack

RMG-06ADPC2

Singlemode (UPC) adapter only packs

 

LC UPC quad adapters, blue color 

 

6 adapters or 24 fiber ports per adapter pack

RMG-24ADPQ8

 

LC UPC quad adapters, blue color 

 

6 adapters or 12 fiber ports per adapter pack

RMG-12ADPQ5

 

SC UPC duplex adapters, blue color 

 

6 adapters or 12 fiber ports per adapter pack

RMG-12ADPC8

 

SC UPC adapters, blue color 

 

6 adapters or 6 fiber ports per adapter pack

RMG-12ADPC7

 

ST UPC adapters  

 

6 adapters or 6 fiber ports per adapter pack

RMG-06ADPT2

ORDERING INFORMATION

RMG Standard Adaptor Packs 

1   

TE recommends the use of aqua colored adapters with laser-optimized 
multimode fiber for 10 Gigabit applications for circuit idendification.

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   56

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - RMG

1-57

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Part Number

RMG-__ ADP__ __ __ __

Pigtail Length

LEAVE

BLANK

Adapters only

03

3 meter pigtails

Pigtail Type

LEAVE

BLANK

Adapters only

B

Singlemode stranded

E

Multimode stranded

Fiber Size

LEAVE

BLANK

Adapters only

B

OM1 – 62.5/125 multimode

D

OM3 – 50/125 LOMMF 300 m

S

Singlemode

Number of Adapters

06

6 simplex adapters

12

6 duplex adapters

24

6 quad adapters

Connector Style

Multimode Connectors

C1

SC

C2

SC (aqua)

2

C3

SC duplex

C4

SC duplex (aqua)

2

Q1

LC1

Q2

LC (aqua)

1,

 

2

Q3

Quad LC

Q4

Quad LC (aqua)

2

T1

ST®

Singlemode Connectors

C7

SC UPC

C8

SC UPC duplex

Q5

LC UPC

1

Q8

LC UPC quad

T2

ST® UPC

Custom Modular Adapter Packs

TE’s RMG modular adapter pack assemblies can be used in any of the RMG series fiber enclosures in a 
variety of connector styles and with or without preterminated 3 m (9.84') pigtails. Its modular design is 
user friendly and easy to install. Use the following matrix to configure the correct catalog number for the 
application. If the resulting catalog number is not on the standard list, the product is considered custom 
and may have longer lead times.

1  

LC adapters terminate two fibers at each adapter and should be considered duplex adapters in this ordering scheme

2

  TE recommends the use of aqua colored adapters with laser optimized multimode fiber applications for 10 Gigabit  

circuit identification.

FEATURES

• 

Can be ordered with all standard types of simplex and duplex multimode and singlemode adapters

• 

Available with preterminated 3 m (9.84') pigtails to reduce installation time and cost

• 

One end of pigtail terminated to chosen connector style and installed into adapter pack plug-in adapters

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   57

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - RMG

1-58

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

RMG Pre-configured Panels with Adapters only or with Pigtails

TE’s RMG series fiber panels are available to be shipped with factory installed adapter modules 
and/or preterminated pigtail assemblies which simplifies the ordering process and reduces installation 
time and costs. These configurations are custom and build-to-order.

Part Number

RMG-__ __ __ - __ __ B

Splice Deck Type

0

None

2

Heat shrink fusion

3

Mechanical fusion

Loaded Adapter Paks

03

3 adapter packs, loaded

06

6 adapter packs, loaded

12

12 adapter packs, loaded

Panel Size

1

1RU (1.75")

3 adapter packs

2

2RU (3.50")

6 adapter packs

4

4RU (7.00")

12 adapter packs

1

   TE recommends the use of aqua colored adapters with laser optimized multimode fiber applications for 10 Gigabit 

circuit identification.

Panel Size

A

Adapters only

P

Adapters and singlemode  
stranded pigtails

D

Adapters and stranded pigtails – OM3

 

50/125 LOMMF 300m1

E

Adapters and stranded – OM1

 

62.5/125 multimode pigtails

Adapters/Pigtails

Multimode Connectors

C1

SC

C2

SC (aqua)

1

C3

SC duplex

C4

SC duplex (aqua)

1

Q1

LC

Q2

LC (aqua)

1

Q3

LC quad

Q4

LC quad (aqua)

1

T1

ST

Singlemode Connectors

C7

SC UPC

C8

SC UPC duplex

Q5

LC UPC

Q8

LC UPC quad

T2

ST UPC

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   58

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - RMG

1-59

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Description

Part Number

Termination only rack or cabinet mount panel, black

 

1RU empty panel, black; accommodates 3 MPO cassettes

RMG-1000-000B

 

2RU empty panel, black; accommodates 6 MPO cassettes

RMG-2000-000B

 

4RU empty panel, black; accommodates 12 MPO cassettes

RMG-4000-000B

Accessory

 

Q-Frame RMG mounting bracket

RMG-
ACCQBRKT4RU

Plug-and-Play Cassettes 

    OM3 50/125

 

12-fiber cassettes; 3 quad LC (aqua) multimode adapters, 1 MPO adapter

RMG-12MPODQ4

 

24-fiber cassettes; 6 quad LC (aqua) multimode adapters, 2 MPO adapter

RMG-24MPODQ4

    OM4 50/125

 

12-fiber cassettes; 3 quad LC (aqua) multimode adapters, 1 MPO adapter

RMG-12MPOFQ4

 

24-fiber cassettes; 6 quad LC (aqua) multimode adapters, 2 MPO adapter

RMG-24MPOFQ4

Singlemode

 

12-fiber cassettes; 3 quad LC (blue) multimode adapters, 1 MPO adapter

RMG-12MPOSQ8

 

24-fiber cassettes; 6 quad LC (blue) multimode adapters, 2 MPO adapter

RMG-24MPOSQ8

ORDERING INFORMATION

RMG Plug-and-Play Cassettes

LC Duplex, 24-fiber

MPO Cassette

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   59

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - RMG

1-60

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

RMG Product Overview

Recommended Applications

Multi-purpose high-density modular solution ideal for 
telecommunications closets or to terminate incoming fiber trunks

Description

Termination, termination/splice

Chassis sizes (in rack units)

1, 2, and 4

Termination only capacity using:

  Simplex adapters
  Duplex adapters
  Small form factor (LC)

18, 36, 72
36, 72, 144 (includes standard LC)
72, 144, 288 (using quad LC)

Flexibility/ablity to grow

Ideal for growth

Interconnect

Yes

Cross-connect

No

Accommodates on-frame splicing

Yes. Built-in

Rear access

Yes

All-front-access

Yes

Customer premises application

Ideal

19" mounting

Yes

23" mounting

Yes, with separate extender bracket

Cabinet mount

Yes

Wall mount

No

Mix equipment with fiber product?

Ideal

Vertical cable guide

No

Features at a Glance

Limited cable management, high density with features and 
price comparable to traditional LGX style panels.

Storage/operating temperature:

-40° C to 85° C (-40° F to 185° F)

Approximate weight (empty panel)

1RU model:

5.44 Kg (12 lbs)

2RU model:

5.90 Kg (13 lbs)

4RU model:

6.80 Kg (15 lbs)

Configuration options and capacity

Termination only
1RU maximum density

1

:

72 terminations

2RU maximum density

1

:

144 terminations

4RU maximum density

1

:

288 terminations

Termination/splice

1RU maximum density:

36 terminations

2RU maximum density:

72 terminations

4RU maximum density:

144 terminations

Maximum density achieved using quad LC connectors.

RMG SPECIFICATIONS

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   60

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - RMG

1-61

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

RMG Maximum Capacity by Adapter Style and Chassis Height

Chassis Height 

(in Rack Units)/ 

Application

Maximum Number of Fiber 

Terminations  

in Chassis

Maximum Number of 

Adapter Packs per 

Chassis

Number of Fiber 

Terminations  

per Adapter Pack

Adapter Style

1

18

3

6

Simplex SC, ST

1

36

3

12

Duplex SC, standard LC,

1

72

3

24

Quad LC

2

36

6

6

Simplex SC, ST

2

72

6

12

Duplex SC, standard LC,

2

144

6

24

Quad LC

4

72

12

6

Simplex SC, ST

4

144

12

12

Duplex SC, standard LC,

4

288

12

24

Quad LC

Chassis Height 

(in Rack Units)/ 

Application

Maximum Number of Fiber 

Terminations  

in Chassis

Maximum Number of 

Adapter Packs per 

Chassis

Number of Fiber 

Terminations  

per Adapter Pack

Adapter Style

1

18

3

6

Simplex SC, ST

1

36

3

12

Duplex SC, standard LC,

1

48

2

24

Quad LC

2

36

6

6

Simplex SC, ST

2

72

6

12

Duplex SC, standard LC,

2

96

4

24

Quad LC

4

72

12

6

Simplex SC, ST

4

144

12

12

Duplex SC, standard LC,

4

144

12

24

Quad LC

TERMINATION ONLY APPLICATION

TERMINATION/SPLICE APPLICATION

Recommended Applications

Multi-purpose high-density modular solution ideal for 
telecommunications closets or to terminate incoming fiber trunks

Description

Termination, termination/splice

Chassis sizes (in rack units)

1, 2, and 4

Termination only capacity using:

  Simplex adapters
  Duplex adapters
  Small form factor (LC)

18, 36, 72
36, 72, 144 (includes standard LC)
72, 144, 288 (using quad LC)

Flexibility/ablity to grow

Ideal for growth

Interconnect

Yes

Cross-connect

No

Accommodates on-frame splicing

Yes. Built-in

Rear access

Yes

All-front-access

Yes

Customer premises application

Ideal

19" mounting

Yes

23" mounting

Yes, with separate extender bracket

Cabinet mount

Yes

Wall mount

No

Mix equipment with fiber product?

Ideal

Vertical cable guide

No

Features at a Glance

Limited cable management, high density with features and 
price comparable to traditional LGX style panels.

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   61

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - TFP

1-62

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Enclosures – TFP Series Rack Mount Fiber Panels

The rack mount TrueNet Fiber Panel (TFP) is an integral part of TE's TrueNet 
fiber product portfolio. The TFP fiber panels can be ordered in one, two, four 
and five rack unit sizes and are completely modular to configure to a variety of 
applications. The unique modular adapter packs incorporate an angled adapter 
design to allow easy access to each port and superior cable management and 
bend radius protection.

FEATURES

• 

TFP panels combine the unique features of vertical cable 
guides and angle-left/angle-right adapters, offering bend radius 
protection, intuitive routing and easy connector access

• 

Rear access makes field termination or splicing fast and efficient. 1RU and 
2RU versions feature convenient sliding access to terminations and splicing

• 

Sold separately for maximum flexibility with minimum 
lead time, TFP adapter packs can also be pre-configured 
at the factory for more efficient service turn-up

• 

288-position high-density termination/splice in the 
space of just five rack units (8.75-inch)

• 

Panels are equipped with adjustable mounting brackets to 
provide either 19- or 23-inch rack or cabinet mounting (EIA 
or WECO) as well as 4- or 5-inch recess mounting

• 

Field-installable vertical cable guides on either side of the panel provide 
bend radius protection and management of fibers exiting the panel

APPLICATIONS AND BENEFITS

• 

Best suited for rack or cabinet mounting in 
horizontal and equipment distribution areas

• 

Modularity, functionality and density make the TFP ideal for 
mounting in close proximity to servers, switches, routers and SANs

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   62

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - TFP

1-63

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Termination only rack or cabinet mount, Black

Dimensions

Part Number

   1RU empty panel, black; accommodates 1 angle LEFT and 

1 angle RIGHT adapter packs; T-handle latch close

1.75"

TFP-1TT00-000B

   2RU empty panel, black; accommodates 2 angle LEFT 

and 2 angle RIGHT adapter packs; T-handle latch close

3.50"

TFP-2TT00-000B

   4RU empty panel, black; accommodates 4 angle LEFT 

and 4 angle RIGHT adapter packs; T-handle latch close

7.00"

TFP-4TT00-000B

   5RU empty panel, black; accommodates 6 angle LEFT 

and 6 angle RIGHT adapter packs; T-handle latch close

8.75"

TFP-5TT00-000B

Accessories

  Heat Shrink Fusion Splice Tray

FST-HS-48

  Velcro Kit for Splice Tray

TFP-VELSTP

  Blank plates

TFP-00AP00

ORDERING INFORMATION

TFP Empty Chassis

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   63

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - TFP

1-64

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

TFP Series Standard Adapter Packs

The TFP series offers a variety of standard modular
adapter packs to accommodate most applications. The
modular design is user-friendly and offers maximum
flexibility to the end-user (for other adapter offerings
or adapter packs loaded with pigtails, see the custom
configuration section).

The TFP modular adapter packs can only be used with
the TFP series panels. They are not interchangeable
with RMG, WMG, FL1000 or FL2000 panels.

ORDERING INFORMATION

1

  TE Connectivity recommends the use of aqua colored adapters with laser-optimized multimode fiber for 10 Gigabit 

applications for circuit identification.

Description

Color

Pack Orientation

Part Number

OM1/OM2 Multimode Adapter Only Packs

    SC duplex adapters 6 adapters or 12 fiber ports per adapter pack

Beige

Left

TFP-12APLC3

Right

TFP-12APRC3

    LC adapters, 12 adapters or 24 fiber ports per adapter pack

Beige

Left

TFP-24APLQ1

Right

TFP-24APRQ1

    SC duplex adapters, 6 adapters or 12 fiber ports per adapter pack

1

Aqua

Left

TFP-12APLC4

Right

TFP-12APRC4

    LC adapters, 12 adapters or 24 fiber ports per adapter pack1

Aqua

Left

TFP-24APLQ2

Right

TFP-24APRQ2

Singlemode Adapter Only Packs

    SC UPC duplex adapters, blue color, 6 adapters or 12 fiber ports per adapter pack

1

Blue

Left

TFP-12APLC8

Right

TFP-12APRC8

    LC UPC adapters, blue color, 12 adapters or 24 fiber ports per adapter pack

1

Blue

Left

TFP-24APLQ5

Right

TFP-24APRQ5

OM3 Multimode Adapter Packs with Stranded Pigtails

SC duplex adapters, 6 adapters or 12 fiber ports per adapter pack

Aqua

Left

TFP-12APLC4DE3

Right

TFP-12APRC4DE3

LC adapters, 12 adapters or 24 fiber ports per adapter pack

Aqua

Left

TFP-24APLQ2DE3

Right

TFP-24APRQ2DE3

Singlemode Adapter Packs with Singlemode Pigtails

SC UPC duplex adapters, 6 adapters or 12 fiber ports per adapter pack

Blue

Left

TFP-12APLC8SB3

Right

TFP-12APRC8SB3

LC UPC adapters, blue color, 12 adapters or 24 fiber ports per adapter pack

Blue

Left

TFP-24APLQ5SB3

Right

TFP-24APRQ5SB3

TFP Fiber Panel

TFP Adapter Pack

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   64

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - TFP

1-65

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

TFP Series Custom Adapter Packs

TE Connectivity's TFP modular adapter packs are available to be shipped from the factory with 
preterminated 3 meter pigtails or in non-standard ST or SC adapter only configurations. These custom 
configurations can simplify the ordering process and reduce installation time and cost for the end-user. 
Please note, these products are non-standard or custom configurations based on the end-user's needs.

Part Number

TFP -  __  ADP  __  __ __ __

Number of Fiber Parts

12

12 fiber ports: 6 LC 
adapters; 6 SC duplex 
adapters; 12 ST adaters

24

24 fiber ports: 12 LC adapters

Fiber Size

Leave 
Blank

Adapters only

B

Multimode 62.5/125

C

Multimode 50/125

D

Multimode 50/125 
ultra (laser optimized 
to 300 meters)

S

Singlemode

Pigtail Length

Leave 
Blank

Adapters only

3

3 meter pigtails

1

Pigtail Type

Leave 
Blank

Adapters only

B

Singlemode stranded

E

Multimode stranded

Adapter Style

Multimode Connectors

C3

SC duplex (beige) with phosphorus/bronze

C4

SC duplex (aqua) with zirconia sleeve

Q1

LC (beige) with phosphorus/bronze

Q2

LC (aqua) with zirconia sleeve

T1

ST with phosphorus/bronze sleeve

Singlemode Connectors

C8

SC duplex (blue) with zirconia sleeve

A1

SC duplex (green) angled polished 
(APC) with zirconia sleeve

Q5

LC (blue) with zirconia sleeve

T2

ST with phosphorus/bronze sleeve

Note:  Adapter packs with pigtails come automatically as a left/right pair. This is to ensure the color order scheme is 

correct on both the angled left and angled right sides. Please use the configurator to select the correct adapter 
pack style and count; a left and right version will be shipped.

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   65

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - TFP

1-66

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

TFP Pre-configured Termination/Splice Fiber Panels

TE Connectivity's TFP series fiber panels are available to be shipped with factory installed adapter packs 
and/or preterminated pigtail assemblies which simplifies the ordering process and reduces installation 
and costs. These products are non-standard or custom configurations based on the end-user's needs.

Panel/Pigtail Type

A

Termination only with adapter packs, no pigtails

P

Termination/Splice with adapter packs 

with singlemode stranded pigtails

B

Termination/Splice with adapter packs with 

50/125 multimode stranded pigtails

D

Termination/Splice with adapter packs 

with 50/125 multimode stranded ultra 
pigtails (laser optimized to 300 meters)

E

Termination/Splice with adapter packs with 

62.5/125 multimode stranded pigtails

Part Number

TFP - __ __ __ __ - __ __ __ __

Panel Size

1T

2RU (1.75")

Accommodates 2 

adapter packs; quarter 
turn latch close

2T

2RU (3.50")

Accommodates 4 

adapter packs; quarter 
turn latch close

5L

5RU (8.75")

Accommodates 12 adapter 

packs; key-lock close

5T

5RU (8.75")

Accommodates 

12 adapter packs; 

T-handle latch close

Loaded Adapter Packs

01

1 adapter pack loaded

02

2 adapter packs loaded

03

3 adapter packs loaded

04

4 adapter packs loaded

06

6 adapter packs loaded

08

8 adapter packs loaded

12

12 adapter packs loaded

Panel Color

B

Black

Splice Deck Type

0

None

1

Heat shrink fusion

Connector Style

Multimode Connectors

C3

SC duplex (beige) with 
phosphorus/bronze sleeve

C4

SC duplex (aqua) with zirconia sleeve

Q1

LC (beige) with phosphorus/bronze sleeve

Q2

LC (aqua) with zirconia sleeve

T1

ST with phosphorus/bronze sleeve

Singlemode Connectors

C8

SC duplex (blue) with zirconia sleeve

A1

SC duplex (green) angle polished 
(APC) with zirconia sleeve

Q5

LC (blue) with zirconia sleeve

T2

ST with phosphorus/bronze sleeve

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   66

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - TFP

1-67

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Recommended Applications

Multi-purpose high-density modular solution ideal for cabinet or rack mount applications near 
servers, switches, routers and SANS

Description

Termination, termination/splice

Chassis sizes

in rack units

1, 2, 4, and 5

Termination only capacity using:

  Simplex adapters
  Duplex adapters
  Small form factor (LC)

24, 48, 96, 144
24, 48, 96, 144
48, 96, 192, 288

Flexibility/ablity to grow

Ideal for growth

Interconnect

Yes

Cross-connect

Yes

Accommodates on-frame splicing

Yes. Built-in

Rear access

Yes

All-front-access

No

Customer premises application

Ideal

19" mounting

Yes

23" mounting

Yes

Cabinet mount

Yes

Wall mount

No

Mix equipment with fiber product?

Ideal

Vertical cable guide

Ships with every panel

Features at a Glance

Angled left/right adapter packs, highest density with maximum cable management features

TFP Product Overview

Storage/operating temperature:

40 to 85° C (-40°  to 185° F)

Approximate weight (empty panel)

1RU model:

8.25 lbs

2RU model:

10.25 lbs

4RU model:

15.91 lbs

5RU model:

15.86 lbs

SPECIFICATIONS

TFP Series Rack Mount Fiber Panels

GENERAL SPECIFICATIONS

Maximum Density

1RU

2RU

4RU 

5R

LC Connector:

48

96

192

288

SC Style Connector:

24

48

96

144

Adapter Pack Configuration:

2 modular adapter packs: 
1 Angle right/
1 Angle left

4 modular adapter packs: 
2 Angle right/
2 Angle left

8 modular adapter packs: 
4 Angle right/
4 Angle left

12 modular adapter packs: 
6 Angle right/
6 Angle left

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   67

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - TFP

1-68

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

TFP Plug-and-Play Cassettes

TE’s TrueNet Fiber Panels (TFP) combine the unique features of vertical cable guides 
and our patented angle-left/angle right adapters, which offer bend radius protection, 
intuitive routing and easy connector access. Our TFP series can be ordered in one, 
two, four or five rack-unit sizes to fit your unique needs. Designed for rack or cabinet 
mounting in the horizontal or equipment distribution area, the TFP’s modularity, 
functionality and density make them ideal for mounting in close proximity to servers, 
switches, routers and SANs.

The TFP’s functionality can be extended with its plug-and-play angled cassettes, 
which add up to 24-fiber terminations each for jumper management in SANs-rich 
environments. These cassettes snap into place effortlessly; and even come from the 
factory prelabeled with simple installation instructions. 

FEATURES

• 

Eliminates the need for on-site fiber terminations, which means rapid deployments

• 

Incorporates angle left/angle right adapters to ensure proper bend radius

• 

Uses the same 1, 2, 4, and 5 rack unit standard TFP chassis, which simplifies ordering

Description

Part Number

Termination only rack or cabinet mount panel, black

  1RU empty panel, black; accommodates 2 plug-and-play cassettes;  T-handle latch close

TFP-1TT00-000B

  2RU empty panel, black; accommodates 4 plug-and-play cassettes;  T-handle latch close

TFP-2TT00-000B

  4RU Termination only empty chassis, accommodates 8 TFP modular adapter packs; black

TFP-4TT00-000B

  5RU empty panel, black: accommodates 12 plug-and-play cassettes;  T-handle latch close

TFP-5TT00-000B

Plug-and-Play Cassettes

OM3 - 50/125 LOMMF 300 m

  12-fiber cassettes; 6 LC (aqua) to 1 MPO adapter 

Angle 

LEFT

 cassette

TFP-12MPLDQ2

Angle 

RIGHT

 cassette

TFP-12MPRDQ2

  24-fiber cassettes; 12 LC (aqua) to 2 MPO adapters

Angle 

LEFT

 cassette

TFP-24MPLDQ2

Angle 

RIGHT

 cassette

TFP-24MPRDQ2

OM4- 50/125 LOMMF 550 m

  12-fiber cassettes; 6 LC (aqua) to  1 MPO adapter

Angle 

LEFT

 cassette

TFP-12MPLFQ2

Angle 

RIGHT

 cassette

TFP-12MPRFQ2

  24-fiber cassettes; 12 LC (aqua) to 2 MPO adapters

Angle 

LEFT

 cassette

TFP-24MPLFQ2

Angle 

RIGHT

 cassette

TFP-24MPRFQ2

Singlemode

  12-fiber cassettes; 6 LCUPC to 1 MPO adapter

Angle 

LEFT

 cassette

TFP-12MPLSQ5

Angle 

RIGHT

 cassette

TFP-12MPRSQ5

  24-fiber cassettes; 12 LCUPC to 2 MPO adapters

Angle 

LEFT

 cassette

TFP-24MPLSQ5

Angle 

RIGHT

 cassette

TFP-24MPRSQ5

ORDERING INFORMATION

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   68

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - TFP

1-69

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

TFP Plug-and-Play Cassettes

Angle Right Polarity/Wiring Scheme
MPO – Fiber Position

LC Connector

Fiber Color

MPO-1

LC-2 and LC-14

Blue

MPO-2

LC-1 and LC-13

Orange

MPO-3

LC-4 and LC-16

Green

MPO-4

LC-3 and LC-15

Brown

MPO-5

LC-6 and LC-18

Slate

MPO-6

LC-5 and LC-17

White

MPO-7

LC-8 and LC-20

Red

MPO-8

LC-7 and LC-19

Black

MPO-9

LC-10 and LC-22

Yellow

MPO-10

LC-9 and LC-21

Violet

MPO-11

LC-12 and LC-24

Rose 

MPO-12

LC-11 and LC-23

Aqua

Angle Left Polarity/Wiring Scheme

MPO – Fiber Position

LC Connector

Fiber Color

MPO-1

LC-1 and LC-13

Blue

MPO-2

LC-2 and LC-14

Orange

MPO-3

LC-3 and LC-15

Green

MPO-4

LC-4 and LC-16 

Brown

MPO-5

LC-5 and LC-17

Slate

MPO-6

LC-6 and LC-18

White

MPO-7

LC-7 and LC-19

Red

MPO-8

LC-8 and LC-20

Black

MPO-9

LC-9 and LC-21

Yellow

MPO-10

LC-10 and LC-22

Violet

MPO-11

LC-11 and LC-23

Rose 

MPO-12

LC-12 and LC-24

Aqua

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   69

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - TFP

1-70

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

OPTICAL SPECIFICATIONS

MPO connector

mated pairs

MPO connector

mated pairs

Plug-and-Play trunks

LC Adapters

TFP Plug-and-Play Cassette

TFP Plug-and-Play Cassette or
Optical Distribution Frame Plug-and-Play Block

MODULE LOSS (MEASURED THROUGH MPO MATED PAIR TO LC ADAPTER):

850 NM

1310 NM

INSERTION LOSS:

Maximum:

0.5 dB

0.55 dB

Typical:

0.25 dB

0.25 dB

RETURN LOSS:

Maximum:

 —

-55 dB

TRUNK LOSS (PER METER):

Maximum:

.0035 dB

.001 dB

CHANNEL/LINK LOSS with 31 m trunk (100')

as in figure above:

Maximum:

1.1085 dB

1.131 dB

Typical:

0.6085 dB

0.531 dB

Panel Configurations

SPECIFICATION

TFP series chassis utilize modular adapter packs which are unique to either the right or left position
of the chassis. The left/right position must be specified to ensure proper adapter orientation and color
order in the backplane. Information below illustrates the various configurations for the three TFP chassis.

5 RU Chassis

MPL

MPR

MPL

MPR

MPL

MPR

MPL

MPR

MPL

MPR

MPL

MPR

1RU Chassis

MPL

MPR

2RU Chassis

MPL

MPR

MPL

MPR

4RU Chassis

MPL

MPR

MPL

MPR

MPL

MPR

MPL

MPR

MPL = angle left plug-and-play cassette
MPR = angle right plug-and-play cassette

ENVIRONMENTAL CHARACTERISTICS

Storage Temperature:

-40° to 70° C

(-40° to 158° F)

Operating Temperature:

0° to 70° C

(32° to 158° F)

Installation Temperature:

0° to 70° C

(32° to 158° F)

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   70

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - TFP

1-71

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber

Fiber Enclosures

FEATURES

• 

Provides higher density in 1, 2RU TFP chassis by terminating 12 fibers in each adapter

• 

Limits insertion loss for loss sensitive optical budgets

• 

Unique angle right/angle left design allows for optimal management of the array 
cables off the front of the panel

TFP MPO Pack

TE introduces an MPO adapter pack for the TrueNet TFP series fiber panel 
enclosures. This unique adapter pack contains 6 MPO adapters to terminate 6 
(12 fiber) MPO trunks in each one. Due to their high density, the MPO adapter 
packs are only available for the 1 and 2RU TFP chassis. With the use of these 
adapter packs, the 1RU will hold 144 fiber terminations, and the 2RU will hold 
288 terminations.

The TFP MPO adapter pack is ideally suited for applications with high-density 
switches, where the additional loss of the MPO cassette is not desired. Either 
the TrueNet Microcable Trunks or High Count plug-and-play trunks can be 
terminated in the back of the adapter pack and a TrueNet plug-and-play array 
cable can be terminated in the front of the adapter pack.

ORDERING INFORMATION

Description

Part Number

Termination Only Rack Mount Panel

1RU empty panel, black; accommodates 2 modular adapter packs; T-handle latch close

TFP-1TT00-000B

2RU empty panel, black; accommodates 24 modular adapter packs; T-handle latch close

TFP-2TT00-000B

MPO adapter pack

Contains 6 MPO adapters; can be installed in either left or right position

TFP-72AP0MP

Cable Clamp

For use with 1/2RU chassis with high fiber count trunk applications

TFP-ACC002

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   71

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-72

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Enclosures – Optical Distribution Frame Solutions

TIA-942 presents the cross-connect architecture as the best practice for Main Distribution 
Area (MDA). Utilizing a centralized cross-connect frame allows maintenance to be performed 
without disrupting the cables attached to active equipment. All moves, adds and changes can 
be performed on the passive cross-connect frame. The benefits of deploying a cross-connect 
architecture in the MDA include: lower operating costs, enhanced reliability, and a reduced risk 
of downtime due to poor fiber jumper management.

Frames

TE developed its innovative Optical Distribution Frame (ODF) for high-fiber count applications. 
At 2304 terminations in a single frame, its unique, user-friendly design and superior cable 
management provide enterprise customers an optimum solution to handle applications with high 
fiber counts such as data centers.

TE’s ODF product line is designed to fit a variety of termination, splice, and storage applications. 
This frame is designed with an emphasis on superior cable management and ease of use, 
including features such as ample trough space for cable and jumpers, easy access to connectors, 
and storage for jumpers. The frame sections are shipped from the factory fully equipped with all 
cable management hardware including a built-in jumper storage panel.

Fiber Termination Blocks (FTBs)

Fiber Termination Blocks (FTBs) are available with SC adapters in block configurations of 
144-positions, and with LC adapters in 144- and 192-positions. FTBs utilize sliding adapter packs 
to gain easy access to both the front and rear connectors. FTBs can be ordered with adapters 
only, with factory terminated IFC stubs, or as plug-and-play cassettes.

Sliding Adapter Packs

Sliding adapter packs house groups of fiber optic adapters and are mounted in fiber termination 
blocks to provide easy access to connectors. Sliding adapter packs are available with SC and LC 
adapters. The adapters come in packs of four and six depending on the adapter type and the 
desired termination density.

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   72

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-73

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

FEATURES

Ample Trough Space

• 

Reduces jumper pile-up and congestion

 

Reduces maintenance time due to easy removal and tracing of jumpers

 

Minimizes risk of microbends or damage to fiber

Built-in Jumper Storage Panel

• 

Minimizes number of required jumper lengths

• 

Maintains fiber bend radius

• 

Simplifies frame installation

 

 Saves money by reducing the number of different jumper lengths that have to be kept in inventory

 

 Minimizes risk of microbends or damage to fiber

• 

 Enclosed system ensures easy cable access without fiber cross-over points

Sliding Adapter Packs

• 

Promotes high density

• 

Provides easy access to connectors

 

Saves valuable floor space

 

Reduces time required for operations and maintenance

Intelligent Cable Routing System

• 

No fiber cross-over points

• 

Multiple vertical troughways

 

Reduces maintenance time due to easier removal and tracing of jumpers and minimizes fiber “weaving”

Bend Radius Protection at Every Turn

• 

 ODF provides complete bend radius at every turn to ensure network performance and reliability

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   73

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-74

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber

Fiber Enclosures

Fiber Main Distribution Frame 
(FMDF)

The FMDF is the cornerstone of the 
ODF product line. This innovative frame 
has six 5" horizontal troughs for a total 
of 30" of horizontal trough space. This 
abundant trough space minimizes 
fiber pile up and congestion leading to 
easier moves, adds and changes. The 
frame has twelve Fiber Termination 
Block (FTB) mounting positions 
equally divided between vertical 
columns on the left and right sides 
of the frame as shown in the figure 
here. The frame is available in 30" 
wide version and provides additional 
vertical trough space for the highest 
termination density applications. The 
built-in jumper storage panel will store 
up to 3.5 m (12') of jumper slack.

FMDF Frame

NGFB-MDF7A144-30

Isolation Pad shown with FMDF

ACCISOP30X24

7’

(2.14 m)

30”

(76.2 cm)

24”

(61 cm)

Each frame section includes heavy duty floor anchor bolts for concrete floor applications. Note: TE recommends the use of 1.7 mm/1.6 mm jumpers 
when deploying 192-position FTBs.

ORDERING INFORMATION

Description

Dimensions (HxWxD)

Part Number

Fiber Main Distribution Frame (FMDF)

 

 Accommodates 12 Fiber Termination Blocks (FTBs) or 12 
Plug-and-Play Cassette Blocks

7' x 30" x 24"

(2.14 m x 76.2 cm x 61 cm)

Short Bracket 30" Frame

 

 For use with SC 144-position FTBs, or LC 192-position FTBs, 
LC 144- and 192-position   
Plug-and-Play Cassette Blocks

1

NGFB-MDF7A144-30

Long Bracket 30" Frame

 

For use with LC 144-position FTBs

NGFB-MDF7A100-30

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   74

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-75

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Optic Terminal Storage Panel

NGFB-ACCFOTSB

Isolation Pad shown with FOTSB

NGF-ACCISOPFS12X24

7'

(2.14 m)

12"

(30.5 cm)

24"

(61 cm)

Note: When using the Fiber Optic Terminal Storage Panels, a cable exit UP block must be used. 

ORDERING INFORMATION

Description

Dimensions (HxWxD)

Part Number

Fiber Optic Terminal Patch Cord Storage Panel

 

Use with FMDF frame 

 

Color: black

7' x 12" x 24"

(2.14 m x 30.5 cm x 61 cm)

NGFB-ACCFOTSB

Isolation Pad - Storage Panel

 

A template for frame installation providing 

 

isolation between the frame and the ground

NGF-ACCISOPFS12X24

Fiber Optic Terminal Patch Cord Storage 
Panel

The fiber optic terminal patch cord storage panel is an 
optional filler panel that provides up to 5 m (16.4') of 
slack storage for patch cords that run between terminal 
equipment and the rear ports of an ODF terminal 
block in cross-connect applications. This slack storage 
capability allows for greater flexibility in determining 
patch cord lengths and allows for use of more standard 
length patch cords. This panel is installed within the 
ODF frame lineup between ODF frames. The fiber optic 
terminal storage panels are available in two different 
configurations depending on the way the ODF frame 
system is zoned. ODF frames can be zoned by vertical 
or by frame. A 12" wide panel is available that serves two 
verticals (one on each side) for use when frames are 
zoned by vertical. Also, 8" wide versions are available 
that serve a single vertical (left or right) for use when 
frames are zoned by frame.

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   75

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-76

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

End Guard

Isolation Pad shown 

with End Guard 

NGF-ACCISOPEG24

7' (2.14 m)

5" (12.7 cm)

24" (61 cm)

ORDERING INFORMATION

Description

Dimensions (HxWxD)

Part Number

End Guard 

     Use with FMDF frames    

Color: black

7' x 5" x 24"

(2.14 m x 12.7 cm x 61 cm)

NGFB-ACCEGD007

Isolation Pad - End Guard

     A template for frame installation providing isolation between 

the frame and the ground

NGF-ACCISOPEG24

End guards provide protection for the fibers 
entering and exiting frames at the end of a 
lineup. They are designed for universal fit to be 
used on either end of the lineup.

ODF Frame

NGFB-MDF7A144-30

End Guard

NGFB-ACCEGD007

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   76

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-77

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

FTBs are available with factory terminated indoor rated cable (IFC) in ribbon or stranded configurations.
All blocks are 100% factory tested to guarantee continuity and reliable connections. Factory terminated
FTBs make installation quick and easy, reducing labor costs. Before ordering, determine the block
orientation and cable exit direction. Factory terminated FTBs may be ordered with a “left” orientation
(mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame).
The cable exit direction will be either “upward” (cables terminated to the rear side of the block exit up
toward the top of the frame) or “downward” (cables terminated to the rear side of the block exit down
toward the bottom of the frame).

Preterminated Fiber 

Termination Blocks  

Arrive from the Factory 

with Either IFC or OSP 

Cables

IFC Cables  

Loaded into FTB

Fiber Cable Easily Uncoils   

During Installation

Fiber Termination Block  

Ships Inside the Drum

1

Block Style 

General adapter type required in the FTB

2

Block Configuration

Maximum number of terminations that the FTB will accommodate when fully loaded

3

Block Orientation

Vertical column of the frame the FTB is to be mounted on

4

Cable Exit Direction

Direction the equipment patch cords or IFC cable will exit from the FTB

5

Adapter/Connector #1

Specific adapter/connector type required in the FTB. Refers to the adapter/connector type at the FTB

6

Connector #2

Specific connector type required at the cable end opposite the FTB

7

Cable Type

Type of cable to be terminated to the FTB

8

Cable Length

Required length of the cable terminated to the FTB

Definition of Variables

Configuration Information

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   77

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-78

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Part Number

NGFB-TB1M __ __ __ __ __ __ __ __ __

Connector Type #2

Singlemode

0

No connector/stub end

7

SC ultra polish

Multimode

0

No connector/stub end

9

SC

6

Block Orientation

L

Left

R

Right

3

Cable Exit Direction

U

Upward

D

Downward

4

Connector and Adapter Type #1

Singlemode

7

SC ultra polish

Multimode

9

SC

T

SC aqua (10 G)

1

5

Cable Length
Standard Single-Ended

016

16 m (50')

023

23 m (75')

031

31 m (100')

046

46 m (150')

061

61 m (200')

077

77 m (250')

092

92 m (300')

122

122 m (400')

153

153 m (500')

Non-Standard

Use XXX for non-standard length in meters

8

Cable Type (IFC Riser)

2

Singlemode

ZD

144-fiber stranded

FJ

144-fiber ribbon

62.5/125 

µ

m Multimode Fiber

YM

144-fiber stranded

50/125 

µ

m Multimode Fiber

VZ

144-fiber stranded

50/125 

µ

m LOMMF 300 m Multimode Fiber

WG

144-fiber stranded

7

 

TE recommends the use of aqua colored adapters with laser optimized multimode fiber for identification of  
10 Gigabit circuits.

 

Panels using TE’s standard cable offering have a shorter lead time than panels using a specific cable manufacturer.  
TE provides GR-409 compliant cable that meets or exceeds our high quality standards. Standard cable offering 
above will use Corning SMF28-e, Sumitomo, Alcatel or similar singlemode fiber based on current market availability.
See previous page for definition of variables.

  Other configurations are available upon request. Please contact TE Technical Assistance Center.

SC style FTB's with Factory Terminated Stubs 144-position Block

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   78

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-79

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Part Number

NGFB-TB4 __ __ __ __ __ __ __ __ __ __

Connector Type #2

Singlemode

0

No connector/stub end

K

LC ultra polish

Multimode

0

No connector/stub end

P

LC

6

Block Capacity

M

144

Q

192

2

Block Orientation

L

Left

R

Right

3

Cable Exit Direction

U

Upward

D

Downward

4

Connector and Adapter Type #1

Singlemode

K

LC ultra polish

Multimode

P

LC

C

LC aqua (10G)

1

5

Cable Length
Standard Single-Ended

016

16 m (50')

023

23 m (75')

031

31 m (100')

046

46 m (150')

061

61 m (200')

077

77 m (250')

092

92 m (300')

122

122 m (400')

153

153 m (500')

Non-Standard

Use XXX for non-standard length in meters

8

Cable Type (IFC Riser)

2

Singlemode

ZD

144-fiber stranded

GT

192-fiber stranded (2 x 96)

FJ

144-fiber ribbon

EJ

192-fiber ribbon

62.5/125 

µ

m Multimode Fiber

YM

144-fiber stranded

MR

192-fiber stranded (2 x 96)

50/125 

µ

m Multimode Fiber

VZ

144-fiber stranded

JM

192-fiber stranded (2 x 96)

50/125 

µ

m LOMMF 300 m Multimode Fiber

WG

144-fiber stranded

TF

192-fiber stranded (2 x 96)

7

 

TE recommends the use of aqua colored adapters with laser optimized multimode fiber for identification of  
10 Gigabit circuits.

 

Panels using TE’s standard cable offering have a shorter lead time than panels using a specific cable manufacturer.  
TE provides GR-409 compliant cable that meets or exceeds our high quality standards. Standard cable offering above 
will use Corning SMF28-e, Sumitomo, Alcatel or similar singlemode fiber based on current market availability. 
See previous page for definition of variables.

  Other configurations are available upon request. Please contact TE Technical Assistance Center.

LC Style FTBs with Factory Terminated Stubs

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   79

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-80

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Termination Blocks (FTBs) – Unterminated (Adapter Only)

FTBs without fiber can be ordered fully loaded with adapters. Before ordering, 
determine the block orientation and cable exit direction. Unterminated FTBs may 
be ordered with a “left” orientation (mounts on the left side of the frame) or a 
“right” orientation (mounts on the right side of the frame). The cable exit direction 
will be either “upward”* (cables terminated to the rear side of the block exit up 
toward the top of the frame) or “downward” (cables terminated to the rear side 
of the block exit down toward the bottom of the frame). All blocks with adapters 
only are configured to terminate single or dual jumpers on the rear of the block. If 
a multifiber breakout style cable (i.e., OSP/IFC) is to be terminated to the rear of 
the block, a separate clamping kit and replacement rear storage area kit is required 
(see next page). FTBs cannot be ordered with a combination of singlemode and 
multimode adapters. If this combination is desired, TE recommends purchasing a 
fully loaded adapter only termination block, and separate sliding adapter packs to 
customize the block on-site.

144-Position Right Upward  

FTB Shown

*Note: When using the Fiber Optic Terminal Storage Panels, a cable exit UP block must be used. 

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   80

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-81

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Termination Blocks (FTBs) – Unterminated (Adapter Only)

Description

Part Number

144-position Blocks

Multimode LC 

    LC (beige) adapters; cable exit up; RIGHT block orientation

NGFB-TB4MRUP

    LC (beige) adapters; cable exit up; LEFT block orientation

NGFB-TB4MLUP

    LC (beige) adapters; cable exit down; RIGHT block orientation

NGFB-TB4MRDP

    LC (beige) adapters; cable exit down; LEFT block orientation

NGFB-TB4MLDP

Multimode SC

    SC (beige) adapters; cable exit up; RIGHT block orientation

NGFB-TB1MRU9

    SC (beige) adapter; cable exit up; LEFT block orientation

NGFB-TB1MLU9

    SC (beige) adapters; cable exit down; RIGHT block orientation

NGFB-TB1MRD9

    SC (beige) adapters; cable exit down; LEFT block orientation

NGFB-TB1MLD9

10G Multimode LC

1

    LC (aqua) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB4MRUC

    LC (aqua) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB4MLUC

    LC (aqua) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB4MRDC

    LC (aqua) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB4MLDC

10G Multimode SC 

    SC (aqua) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB1MRUT

    SC (aqua) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB1MLUT

    SC (aqua) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB1MRDT

    SC (aqua) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB1MLDT

Singlemode LC  

    LC (blue) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB4MRUK

    LC (blue) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB4MLUK

    LC (blue) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB4MRDK

    LC (blue) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB4MLDK

Singlemode SC 

    SC (blue) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB1MRU7

    SC (blue) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB1MLU7

    SC (blue) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB1MRD7

    SC (blue) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB1MLD7

ORDERING INFORMATION 

1

   TE recommends the use of aqua colored adapters with laser optimized multimode fiber for identification of 10 Gigabit circuits.

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   81

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-82

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

ORDERING INFORMATION, continued

Description

Part Number

192-position Blocks 

Multimode LC 

    LC (beige) adapters; cable exit up; RIGHT block orientation

NGFB-TB4QRUP

    LC (beige) adapters; cable exit up; LEFT block orientation

NGFB-TB4QLUP

    LC (beige) adapters; cable exit down; RIGHT block orientation

NGFB-TB4QRDP

    LC (beige) adapters; cable exit down; LEFT block orientation

NGFB-TB4QLDP

10G Multimode LC

1

 

    LC (aqua) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB4QRUC

    LC (aqua) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB4QLUC

    LC (aqua) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB4QRDC

    LC (aqua) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB4QLDC

Singlemode LC  

    LC (blue) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB4MRUK

    LC (blue) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB4MLUK

    LC (blue) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB4MRDK

    LC (blue) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB4MLDK

1

   TE recommends the use of aqua colored adapters with laser optimized multimode fiber for identification of 10 Gigabit circuits.

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   82

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-83

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Termination Blocks (FTBs)

Adapter-only blocks are configured to accommodate single fiber jumpers or multifiber breakout cables.
If loading a preterminated intrafacility (IFC) cable or a preterminated OSP cable is desired, additional
hardware will be required. Block conversion kits are available to convert adapter only blocks to blocks
that will accept preterminated IFC or OSP style cables. The conversion kits contain the cable management
hardware, brackets and cable clamps required to convert the block. The kit required will depend on the block
style originally purchased.

Description

Part Number

Block style originally purchased

144- or 192-position 

left up

 blocks

NGFB-ACCRCMSLU

144- or 192-position 

right up

 blocks

NGFB-ACCRCMSRU

144- or 192-position 

left down

 blocks

NGFB-ACCRCMSLD

144- or 192-position 

right down

 blocks

NGFB-ACCRCMSRD

72-Position Block

Loaded with Jumpers

72-Position Block

Loaded with Multifiber Breakout Cable

Cable 

Clamp

Cable Clamping/Block Conversion Kits

Definition of Variables

CONFIGURATION INFORMATION

1

Block Style 

General adapter type required in the FTB

2

Block Configuration 

Maximum number of terminations that the FTB will accommodate when fully loaded

3

Block Orientation 

Vertical column of the frame the FTB is to be mounted on

4

Cable Exit 

Direction Direction the equipment jumpers or OSP cable will exit from the FTB

5

Adapter Type 

Specific adapter type required in the FTB

ORDERING INFORMATION

Rear Cable Management Tray

for 144 Block Conversion Kit

Fanout 

Bracket

Protective 

Cover

72-Position Block  

with Clamping Kit

Description

Part Number

192-position Blocks 

Multimode LC 

    LC (beige) adapters; cable exit up; RIGHT block orientation

NGFB-TB4QRUP

    LC (beige) adapters; cable exit up; LEFT block orientation

NGFB-TB4QLUP

    LC (beige) adapters; cable exit down; RIGHT block orientation

NGFB-TB4QRDP

    LC (beige) adapters; cable exit down; LEFT block orientation

NGFB-TB4QLDP

10G Multimode LC

1

 

    LC (aqua) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB4QRUC

    LC (aqua) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB4QLUC

    LC (aqua) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB4QRDC

    LC (aqua) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB4QLDC

Singlemode LC  

    LC (blue) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB4MRUK

    LC (blue) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB4MLUK

    LC (blue) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB4MRDK

    LC (blue) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB4MLDK

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   83

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-84

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Sliding Adapter Packs

Sliding adapter packs house groups of fiber optic adapters and are 
mounted in Fiber Termination Blocks to provide easy access to connectors. 
Sliding Adapter Packs are available with SC and LC adapters. The adapters 
come in packs of six and eight depending on the adapter type and the 
desired termination density. See table below for configuration guidelines.

SLIDING ADAPTER PACK CONFIGURATION GUIDELINES SPECIFICATIONS

Block Configuration

Adapter Type

Adapter Pack Configuration

Adapter Pack Option

144-Position (block code 'M')

SC, LC

6 Pack/6 Pack

K

192-Position (block code 'Q')

LC

8 Pack/8 Pack

J

SC pack

Style K

LC pack 144-position 

Style K

Description

Part Number

1

144-position Blocks 

   Multimode LC

NGF-SAPP0K00

   Multimode SC

NGF-SAP90K00

   10G Multimode LC

1

NGF-SAPC0K00

   10G Multimode SC

1

NGF-SAPT0K00

   Singlemode LC

NGF-SAPK0K00

   Singlemode SC

NGF-SAP70K00

192-position Blocks  

   Multimode LC

NGF-SAPP0J00

   10G Multimode LC

1

NGF-SAPC0J00

   Singlemode LC

NGF-SAPK0J0

1

   TE recommends the use of aqua colored adapters with laser optimized multimode fiber for 10 Gigabit circuit identification.

Note: TE recommends the use of 1.7 mm/1.6 mm jumpers when deploying 192-position FTBs.

ORDERING INFORMATION

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   84

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-85

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Data Center Optical Distribution Frame with Plug-and-Play Cassettes

TE’s data center optical distribution frame (ODF) with plug-and-play (MPO) 
cassettes is the highest density optical distribution frame solution available 
today. It efficiently manages up to 1,728 fiber terminations using the 144-position 
block in a single frame in either a cross-connect or inter-connect design. 

Its patented design incorporates the fundamentals of cable management while 
using the industry’s highest fiber count MPO plug-and-play cassettes. 

FEATURES

• 

Rapid installation of new deployments

• 

MPO trunks can enter rack from either under-floor or overhead

• 

Slack storage included in each rack allows for the use of a single 
jumper length

• 

On frame jumper routing provides bend radius and physical 
protection with slack easily and intuitively managed

APPLICATIONS

• 

Provides managed high-density solution for optical distribution 
frames in the main distribution area of the data center

• 

Can be successfully deployed in the cross-connect architecture 
recommended in TIA-942, and still provide clear, managed 
pathways for fiber

ORDERING INFORMATION

Description

Part Number

144-position MPO – LC Blocks; Black

   OM3–50/125 LOMMF 300 meters

     

LEFT

 block orientation

NGFB-MPML0C112

     

RIGHT

 block orientation

NGFB-MPMR0C112

   OM4-50/125 LOMMF 550 meters

     

LEFT

 block orientation

NGFB-MPML0C612

     

RIGHT

 block orientation

NGFB-MPMR0C612

   Singlemode

     

LEFT

 block orientation 

NGFB-MPML0K512

     

RIGHT

 block orientation

NGFB-MPMR0K512

Rack

   

30" x 24" x 7' frame; black

NGFB-MDF7A144-30

Rack Accessories

   

ISO pad

NGF-ACCIOSP30X24

   

End guard

NGFB-ACCEGD007

   

End guard ISO pad

NGF-ACCISOPEG24

   

Rack installation kit raised floor

FDF-ACC146

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   85

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-86

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

FIBER

Data Center Optical Distribution Frame with Plug-and-Play Cassettes Specifications

CONNECTION TABLE 144 POS

MPO CONECTOR TRAY 

FIBER

COLOR

1-48

49-96

97-144

FIBER BUNDLE NUMBER

1

2

3

4

5

6

7

8

9

10

11

12

T/B POSITION

1

13

25

37

49

61

73

85

97

109

121

133

BLUE

2

14

26

38

50

62

74

86

98

110

122

134

ORANGE

3

15

27

39

51

63

75

87

99

111

123

135

GREEN

4

16

28

40

52

64

76

88

100

112

124

136

BROWN

5

17

29

41

53

65

77

89

101

113

125

137

SLATE

6

18

30

42

54

66

78

90

102

114

126

138

WHITE

7

19

31

43

55

67

79

91

103

115

127

139

RED

8

20

32

44

56

68

80

92

104

116

128

140

BLACK

9

21

33

45

57

69

81

93

105

117

129

141

YELLOW

10

22

34

46

58

70

82

94

106

118

130

142

VIOLET

11

23

35

47

59

71

83

95

107

119

131

143

ROSE

12

24

36

48

60

72

84

96

108

120

132

144

AQUA

Left Side

1

2
3

4

5

6
7

8

9

10
11

12

Fiber Bundle/MPO Connector Locations

Position #144

Position #12

SPECIFICATIONS

MPO connector

mated pairs

MPO connector

mated pairs

Plug-and-Play trunks

LC Adapters

TFP Plug-and-Play Cassette

TFP Plug-and-Play Cassette or
Optical Distribution Frame Plug-and-Play Block

OPTICAL SPECIFICATIONS

Top View

Plug-and-Play

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-87

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber

Fiber Enclosures

MODULE LOSS (measured through MPO mated pair to LC adapter)

850 nm

1310 nm

INSERTION LOSS:

Maximum:

0.7 dB

0.55 dB

Typical:

0.25 dB

0.25 dB

RETURN LOSS:

Maximum:

  —

-55 dB

TRUNK LOSS (PER METER):

Maximum:

.0035 dB

.001 dB

CHANNEL/LINK LOSS: 

with 31 m trunk (100')

Maximum:

1.3085 dB

1.131 dB

Typical:

0.6085 dB

0.531 dB

ENVIRONMENTAL CHARACTERISTICS

Storage Temperature:

-40° to 70° C (-40° to 158° F)

Operating Temperature:

0° to 70° C (32° to 158° F)

Installation Temperature:

0° to 70° C (32° to 158° F)

Data Center Optical Distribution Frame with Plug-and-Play Cassettes 

SPECIFICATIONS

Description

Part Number

144-position MPO – LC Blocks; Black

   OM3–50/125 LOMMF 300 meters

      LEFT 

block orientation

NGFB-MPML0C112

      RIGHT 

block orientation

NGFB-MPMR0C112

   OM4-50/125 LOMMF 550 meters

      LEFT 

block orientation

NGFB-MPML0C612

      RIGHT 

block orientation

NGFB-MPMR0C612

Singlemode

      LEFT 

block orientation 

NGFB-MPML0K512

      RIGHT 

block orientation

NGFB-MPMR0K512

Rack

   30" x 24" x 7' frame; black

NGFB-MDF7A144-30

Rack Accessories

   ISO pad

NGF-ACCIOSP30X24

   End guard

NGFB-ACCEGD007

   End guard ISO pad   

NGF-ACCISOPEG24

   Rack installation kit raised floor

FDF-ACC146

ORDERING INFORMATION

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   87

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-88

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Cable clamp kits are available for securing IFC/OSP cable or equipment jumpers on the rear of the FTB. 
Each FTB has three cable clamp mounting positions.

Description

Part Number

Cable clamp kit

 for equipment patch cords (included with fiber termination blocks loaded with adapters only)

NGF-ACCCLMP04

Cable clamp kit*

 for trunk cables, dielectric cable without grounding hardware  

(included with fiber termination blocks with IFC)

NGF-ACCCLMP08

Cable Clamp Kit

* One NGF-ACCCLMP08 is also included with each cable clamp kit and block conversion kit

Cable clamp kit for active equipment patch cord includes:

• 

Cable clamp bracket

1 each

• 

O-ring

1 each

• 

Screws

2 each

Cable clamp kit for trunk cables includes:

• 

Clamp cover

1 each

• 

Clamps

2 each

• 

0.5" Grommet (inner diameter)

1 each

• 

0.6" Grommet (inner diameter)

1 each

• 

0.7" Grommet (inner diameter)

1 each

• 

#14 - #6 AWG split bolt

1 each

• 

Shield bonding connector

1 each

• 

1-foot lead wire

1 each

• 

#6 AWG ring terminal lug

1 each

• 

Clamp cover plate

1 each

ORDERING INFORMATION

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   88

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - Optical Distribution Frame Solutions

1-89

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Frame Installation Kit

Frame installation kits may be used on network frames and are seismic zone 4 rated.

Computer floor kit includes:

• 

Threaded rods 

4 each, 

5

/

8

" – 11" x 30"

• 

Heavy nuts, locks and flat washers

12 each

• 

Nuts with springs 

4 each, 

1

/

2

" x 30" and shoulder washers

• 

Unistrut and anchor kit

1 each, 10'

Overhead support kit includes:

• 

Designation card holder

1 each

• 

Two-bar channel

4 each

• 

Framing clip with 0.56

4 each

• 

Framing clip with 0.69

4 each

• 

Clip J-bolt 

4 each, 

1

/

2

" – 13" x 18" long

• 

Threaded rod 

2 each, 

5

/

8

" x 18" long

• 

Hex nut 

4 each, 

1

/

2

" x 13"

• 

Hex nut 

4 each, 

5

/

8

" x 11"

Total Number of 
Sections Traversed

1

Approximate

Patch Cord Length

Meters (Feet)

Same frame

 

6 m (18')

Adjacent frames

 

7 m (23')

3 to 4

 

8 m (26')

5 to 6

 

10 m (33')

7 to 8

 

11 m (36')

9 to 10

 

12 m (39')

Standard Cross-Connect Patch Cord Lengths

SPECIFICATIONS

1  

 

Depending on office requirements, 11 or more frame sections may require the use of interbay tie panels.  

For additional information, please call TE Technical Assistance Center, 1-800-366-3891.
For recommended cross-connect method and installation instructions, refer to User Manual ADCP-90-285.

ORDERING INFORMATION

Description

Part Number

Frame installation kit

 for computer floor 

FDF-ACC146

Overhead support 

RINST-TOP7

Description

Part Number

Cable clamp kit

 for equipment patch cords (included with fiber termination blocks loaded with adapters only)

NGF-ACCCLMP04

Cable clamp kit*

 for trunk cables, dielectric cable without grounding hardware  

(included with fiber termination blocks with IFC)

NGF-ACCCLMP08

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   89

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - WMG

1-90

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber

Fiber Enclosures

FEATURES

• 

Optional integrated splice module on the four and eight module panel version

• 

Utilizes standard RMG series adapter packs

• 

Compact design

• 

Fully enclosed design, with optional field installable locks

• 

Wrap-around client-side door design provides maximum adapter accessibility 
for client-side patching

• 

Multi-sized cable entry knockouts supports either 

1

/

2

" or 

3

/

4

" cable grommets 

for maximum cable strain relief and protection

Fiber Enclosures – WMG Series Wall Mount Fiber Enclosures

TE Connectivity's TrueNet WMG series wall mount fiber enclosures are ideal for 
LAN applications requiring a fully enclosed and lockable wall mount enclosure. 
The cabinets are one or two door direct termination and splice solutions. These 
enclosures are designed to support up to eight modular adapter packs. The 
rugged wall mount cabinet is equipped with cable management modules and 
cable routing accessories to limit bend radius and add strain relief control. In 
addition, the lockable dual door design allows public and private portions of the 
network to be securely separated from each other. For splicing applications, the 
cable management modules are removed and replaced with splice modules and 
up to four 8", 12-fiber splice trays. This enclosure is available pre-loaded with any 
industry standard adapter. Optional single or double lock features are available 
upon request.

ORDERING INFORMATION

Product Description

Dimensions

Part Number

Wall mount fiber enclosure, black

Empty wall box, maximum capacity 2 adapter packs

22.86 cm x 30.48 cm x 8.89 cm

(9" x 12" x 3.5")

WMG-2000-00B

Empty wall box, maximum capacity 4 adapter packs

30.48 cm x 38.1 cm x 8.89 cm

(12" x 15" x 3.5")

WMG-4000-00B

Empty wall box, maximum capacity 8 adapter packs

35.56 cm x 43.82 cm x 17.78 cm

(14" x 17.25" x 7")

WMG-8000-00B

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   90

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - WMG

1-91

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Description

Part Number

OM1/OM2 Multimode adapter only packs

 

LC quad adapters, beige color 

 

6 adapters or 24 fiber ports per adapter pack

RMG-24ADPQ3

 

LC adapters, beige color 

 

6 adapters or 12 fiber ports per adapter pack

RMG-12ADPQ1

 

SC duplex adapters, beige color 

 

6 adapters or 12 fiber ports per adapter pack

RMG-12ADPC3

 

SC adapters, beige color 

 

6 adapters or 6 fiber ports per adapter pack

RMG-06ADPC1

 

ST adapters  

 

6 adapters or 6 fiber ports per adapter pack

RMG-06ADPT1

OM3/OM4 multimode adapter only packs

 

LC quad adapters with zirconia sleeve, aqua color 

 

6 adapters or 24 fiber ports per adapter pack

RMG-24ADPQ4

 

LC adapters with zirconia sleeve, aqua color 

 

6 adapters or 12 fiber ports per adapter pack

RMG-12ADPQ2

 

SC duplex adapters with zirconia sleeve, aqua color 

 

6 adapters or 12 fiber ports per adapter pack

RMG-12ADPC4

 

SC adapters with zirconia sleeve, aqua color 

 

6 adapters or 6 fiber ports per adapter pack

RMG-06ADPC2

Singlemode (UPC) adapter only packs

 

LC quad adapters, blue color 

 

6 adapters or 24 fiber ports per adapter pack

RMG-24ADPQ8

 

LC quad adapters, blue color 

 

6 adapters or 12 fiber ports per adapter pack

RMG-12ADPQ5

 

SC duplex adapters, blue color 

 

6 adapters or 12 fiber ports per adapter pack

RMG-12ADPC8

 

SC adapters, blue color 

 

6 adapters or 6 fiber ports per adapter pack

RMG-06ADPC7

 

ST adapters  

 

6 adapters or 6 fiber ports per adapter pack

RMG-06ADPT2

ORDERING INFORMATION

WMG Standard Adapter Packs

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   91

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - WMG

1-92

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

SPECIFICATIONS

STORAGE/OPERATING TEMPERATURE:

-40 to 85° C (-40 to 185° F)

APPROXIMATE WEIGHT

(empty panel):

2 adapter model:

2.5 Kg (5.5 lbs)

4 adapter model:

3.7 Kg (8.25 lbs)

8 adapter model:

6.2 Kg (13.75 lbs)

DIMENSIONS:

2 adapter model:

22.9 cm x 30.5 cm x 8.9 cm (9" x 12" x 3.5")

4 adapter model:

30.5 cm x 38.1 cm x 8.9 cm (12" x 15" x 3.5")

8 adapter model:

35.5 cm x 43.8 cm x 17.8 cm (14" x 17.25" x 7")

CONFIGURATION OPTIONS AND CAPACITY:

Termination only

2 adapter model:

24 terminations

4 adapter model:

48 terminations

8 adapter model:

96 terminations

TERMINATION/SPLICE:

2 adapter model:

not available

4 adapter model:

48 terminations

8 adapter model:

96 terminations

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   92

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures – FL2000

1-93

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Enclosures – FL2000 System

The economical and flexible FL2000 series of fiber optic products is ideal 
for small fiber counts and can be used in moderate fiber count applications 
as well by combining various panels.

FL2000 termination only chassis

FL2000 termination/splice chassis

FEATURES

• 

Designed for 19-inch (48.26 cm) EIA rack or cabinet environment; optional 
brackets are available to accommodate 23" (58.42 cm) rack or cabinet 
mounting, or virtually any mounting application

• 

 Modular design offers maximum flexibility to satisfy both current needs and 
future growth requirements

• 

A full line of options and accessories ensures compatibility with existing  
optical equipment

• 

All FL2000 panels accommodate the modular FL2000 6pak plug-ins. 6paks 
are available in all connector styles and can be ordered as needed

• 

TE’s patented removable angled retainers allow easy access for single  
fiber maintenance

• 

FL2000 panels and feature superior vertical cable protection and management

• 

Rack mount panels are hinged on one side, allowing full access to the rear of 
the front plate and the interior of the panel

• 

Rack mount panels can be wall mounted

• 

 The new FL2000 splice wheel allows easy roll-up of pigtail and buffer tube 
lengths and superior bend radius protection

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   93

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures – FL2000

1-94

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Description

Height

Part Number

Termination/Splice panel, black

   12-Position

3.5" (8.89 cm)

FL2-12TS350-B

   24-Position

5.25" (13.34 cm)

FL2-24TS525-B

   48-Position

8.75" (22.23 cm)

FL2-48TS875-B

   72-Position

14" (35.56 cm)

FL2-72TS140-B

FEATURES

• 

Mounting

 

 19-inch (48.26 cm) EIA racks or cabinets, standard 5" (12.7 cm) recess

 

Wall mounting option available

 

Other mounting kits available

• 

 Hinged on left front side

1

 for complete access to interior of termination section

• 

 Ability to quickly and easily configure, utilizing the 6pak assemblies (ordered separately)

• 

 Complete line of accessories including locks for security

• 

Uses TE splice wheels or splice decks

1

Right hinged also available

ORDERING INFORMATION

Empty Termination/Splice Panels, Black

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   94

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures – FL2000

1-95

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Description

Height

Part Number

Rack or cabinet mount panel, black 

Includes vertical cable management trough

    12 Fiber Capacity

1.75" (4.45 cm)

FL2-12RPNL-B

    24 Fiber Capacity

3.50" (8.89 cm)

FL2-24RPNL-B

    36 Fiber Capacity

5.25" (13.34 cm)

FL2-36RPNL-B

    48 Fiber Capacity

5.25" (13.34 cm)

FL2-48RPNL-B

    72 Fiber Capacity

8.75" (22.23 cm)

FL2-72RPNL-B

    96 Fiber Capacity

10.50" (26.67 cm)

FL2-96RPNL-B

ORDERING INFORMATION

FEATURES

• 

Mounting

19-inch (48.26 cm) EIA rack or cabinets, standard 5" (12.7 cm) recess

Wall mounting option available

Other mounting kits available

• 

Hinged on left front side

 1

 allows full access to rear of front plate and interior of panel

• 

FL2000 6pak adapter plug-ins ordered separately

• 

Constructed of high strength aluminum

• 

Equipped with removable metal doors with Plexiglas windows

• 

Designation labels included with each panel

• 

Complete line of accessories including locks for security

1

Right hinged also available

Empty Termination Panels, Black

Plexiglas is a trademark.

Description

Height

Part Number

Termination/Splice panel, black

   12-Position

3.5" (8.89 cm)

FL2-12TS350-B

   24-Position

5.25" (13.34 cm)

FL2-24TS525-B

   48-Position

8.75" (22.23 cm)

FL2-48TS875-B

   72-Position

14" (35.56 cm)

FL2-72TS140-B

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   95

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures – FL2000

1-96

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

FEATURES

• 

Offers combination of splicing protection and associated fiber/pigtail storage

• 

Splice panel can be mounted in conjunction with any FL2000 termination panel or as a stand-alone splice panel

• 

Occupies same footprint and offers same mounting options as FL2000 termination panels

• 

Accepts the TE splice wheel for efficient management of fiber cable and splice protection

• 

Accepts the traditional TE splice deck

Empty Splice Panels, Black

Description

Height

Part Number

Empty Splice Panels, 

splice panel for splice wheel, black

   48 Fiber Capacity

3.5" (8.89 cm)

FL2-48SPNL2-B

   96 Fiber Capacity

7" (17.78 cm)

FL2-96SPNL2-B

   144 Fiber Capacity

8.75" (22.23 cm)

FL2-144SPNL2-B

Cable clamp kit

FL2-ACC007

ORDERING INFORMATION

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   96

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures – FL2000

1-97

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

6pak Connector Plug-Ins

FEATURES

• 

Completely interchangeable between FL2000 panel and wall box products

• 

Can be ordered with all standard types of simplex and duplex single and 
multimode adapters and connectors

• 

TE’s patented removable angled retainers provide superior fiber 
management

• 

No tools required to install into FL2000 boxes or panels

• 

Can be ordered with adapters only, or for quick and easy installation, with 
preterminated 3 m (9.84') or 5 m (16.4') pigtails

6pak plug-in 

shown with singlemode simplex adapters

6pak plug-in 

shown with multimode simplex adapters

6pak plug-in  

shown with singlemode duplex adapters

6pak plug-in 

shown with multimode duplex adapters

Description

Part Number

Multimode

   SC

FL2-6PMMSC

   SC (aqua

1

)

FL2-6PMMSC-A

   ST

FL2-6PMMST

   SC (duplex)

FL2-6PMMDSC

   SC (aqua

1

, duplex)

FL2-6PMMDSC-A

   LC

FL2-6PMMLC

   LC (aqua

1

)

FL2-6PMMLC-A

Singlemode

   SC

FL2-6PSMSC

   ST

FL2-6PSMST

   SC (duplex)

FL2-6PSDSC

   LC

FL2-6PSMLC

6pak blank plug-in

FL2-PBLNK

1

  TE recommends the use of aqua colored adapters with laser optimized 

multimode fiber applications for 10 Gigabit circuit identification.

ORDERING INFORMATION

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   97

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures – FL2000

1-98

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

6pak Connector Plug-Ins with Adapters and Pigtails

FL2000 6pak plug-in 

with SC adapters and pigtails

FEATURES

• 

Available with preterminated 5 m (16.4') pigtails

• 

Pigtails consist of a single outer jacket containing six color-coded 
900 

µ

m fibers

• 

One end of pigtail terminated to chosen connector style and installed into 
the 6pak plug-in adapters

• 

TE recommends specific breakouts for panel and wall mount box products

• 

Saves installation time

Description

Part Number

OM3 6paks – with 50/125 

µ

m Laser Optimized Multimode Pigtails

1

 

 

Multimode LC (aqua), with 5 m 12 fiber OM3 stranded pigtails

 FL2-6P6JC605R 

 

Multimode SC (aqua), with 5 m 6 fiber OM3 stranded pigtails

 FL2-6P9JC605R 

 

Multimode SC duplex (aqua), with 5 m 6 fiber OM3 stranded pigtails

 FL2-6PDJC605R

6paks - Singlemode Pigtails and Adapters

 

LC UPC (blue), with 5 m 12 fiber singlemode stranded pigtails

 FL2-6P8SC605R

 

SC UPC (blue), with 5 m 6 fiber singlemode stranded pigtails

 FL2-6P7SC605R

 

ST UPC, with 5 m 6 fiber singlemode stranded pigtails

 FL2-6P4SC605R

ORDERING INFORMATION

1

  10G 6paks utilize 50/125 

µ

m laser optimized multimode to 300 m or OM3 rated glass and aqua colored adapters.

Please note: Duplex SC adapters do not double the fiber count per adapter pack.

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   98

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures – FL2000

1-99

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

10.14"

(25.76cm)

4.95"

(12.58cm)

19.60"

(49.79cm)

5.25"

(13.34cm)

Part Number

FL2-  C __   __ 0 __   __   __   __   __   __   __   __   __

 

5  6  7 

8  9  10  11 

             

Pigtail or Adapter Type 

Multimode Connectors

A

Adapters only

J

Softwall bundle OM3 
multimode 50/125 
LOMMF 300 m

Singlemode Connectors

P

Softwall bundle 

H

6-fiber maxistrip

R

12-fiber ribbon

3

Y

12-fiber maxistrip

4

Splice Type

0

None or N/A

M

Mechanical (wheel)

W

Heat shrink 
fusion (wheel)

Connector Style 

Multimode Connectors

9

SC

D

SC Duplex

5

ST®

6

LC

Singlemode Connectors

7

SC UPC

E

SC UPC Duplex

4

ST® UPC

8

LC UPC

FEATURES

FL2000 panels can also be shipped with 6paks and/or pigtails 
pre-installed at the factory.

• 

Reduce installation time

• 

Simplify ordering process

Use this configuration guide to determine the catalog number 
right for your application.

Pre-configured Termination/Splice Panels, Black

Nominal Capacity     Panel Height

A

12 position

3.5" (8.89 cm) (2RU)

B

24 position

5.25" (13.34 cm) (3RU)

D

48 position

8.75" (22.23 cm) (5RU)

E

72 position

14.00" (35.56 cm) (8RU)

F

96 position

17.50" (44.45 cm) (10RU)

Latch Type

0

Standard

1

Hole plug

2

Screwdriver

5

K1 Lock

6

K2 Lock

Number of Cable Clamps

0

1 Clamp (Standard)

2

2 Clamps

Mounting Style

4

A

19" (8.26 cm) Standard 
(19.6" [49.78 cm] overall)

C

19" (48.26 cm) flush mount

Number 
of Ports 
Loaded

Number  
of Splice 
Decks

1

   LC connectors and adapters double the capacity of the panel by terminating two fibers at each adapter.

2

   TE will automatically configure FL2000 panels with laser optimized cable to use aqua colored SC or LC adapters to indicate 10 Gigabit 

applications. To order adapter only panels with aqua colored adapters, purchase the empty chassis and add 6paks separately.

3

   Singlemode choices for use with LC adapters, with multimode options TE will automatically choose best suited fiber count.

4

   Mounting kit shipped unattached if other than standard mounting style.

12

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   99

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures – FL2000

1-100

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Recommended Applications

Multi-purpose modular solution ideal for cabinet, rack, wall mount or medium 
size frame applications. Ideal for small to medium fiber counts.

Description

Termination, termination/splice

Chassis sizes (in rack units)

1, 2, 3, 5, 6 (termination only chassis) 
2, 3, 5, 8, 10 (termination/splice chassis)

Termination only capacity using:

   Simplex adapters
   Duplex adapters
   Small form factor (LC)

 
12, 24, 48, 72, 96
12, 24, 48, 72, 96
24, 48, 72, 144, 192

Flexibility/ablity to grow

Ideal for growth

Interconnect

Yes

Cross-connect

Yes

Accommodates on-frame splicing

Yes. Built-in

Rear access

Not required

All-front-access

Yes

Customer premises application

Ideal

19" mounting

Yes

23" mounting

Yes

Cabinet mount

Yes

Wall mount

Yes

Mix equipment with fiber product?

Ideal

Vertical cable guide

Ships with every panel

Features at a glance

Locking or latching door, within panel splice wheel, all front access, modular angle left 6paks.

SPECIFICATIONS

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   100

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - OMX

1-101

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Fiber Enclosures – OMX Splice Cabinet

The data center splice cabinet is a high-
density splice solution, housing up to 1,440
splices within a 23.6" by 11.8" footprint.
Shipped complete with the necessary cable
management, it features slots which secure
and protect the round splice trays and can
hold up to sixty 12-fiber splice trays on which
the cables enter from above or below.

OMX Splice Cabinet Doors

Open and Closed 

MX6-BSPL-1440-U7 

7'

(2.14 m)

24"

(61 cm)

12"

(30.5 cm)

Isolation Pad shown with

OMX Cabinet 

MX6-BAYTEMPLATE

ORDERING INFORMATION

Description

Dimensions (HxWxD)

Part Number

Fully Configured Splice Cabinet 

Accommodates up to 1440 fiber splices
Cable enters from top 
Color: black

7’ x 24” x 12”

(2.14 m x 61 cm x 30.5 cm)

Cabinet - Cable Exit Up

Cable enters from above
Color: black 

MX6-BSPL-1440-U7

Cabinet - Cable Exit Down

Cable enters from below 
Color: black

MX6-BSPL-1440-D7

Isolation Pad - Splice Cabinet

A template for cabinet installation providing 
isolation between the cabinet and the ground

MX6-BAYTEMPLATE

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   101

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Enclosures - OMX

1-102

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Splice Wheel

Cable Clamps

FEC-ACCCLMP01

MX6-SPLIFCCLMP

Description

Part Number

OMX Splice Frame Cable Clamps

    For OSP Cable
    For IFC Cable

FEC-ACCCLMP01 
MX6-SPLIFCCLMP

Description

Part Number

Splice Wheel

      Accommodates up to 24 fiber splices, heat shrink fusion chip
    Accommodates 2x12 mass ribbon fusion splices

FST-DRS24-NT
FST-DRS12-MT

ORDERING INFORMATION

ORDERING INFORMATION 

Sc1_Fiber_03_PanleFrameEnclose_v1.indd   102

12/11/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Storage Area Management (SAN Fiber Channel Management) 

1-103

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

FIBER

Storage Area Management (SAN Fiber Channel Management)

TE Connectivity's Storage Area Management (SAM) solution for network
infrastructures is designed to reduce the bulkiness of cabling in the data
center by up to 80% and enable high-density deployment with fewer costly
cabinet or infrastructure upgrades. SAM can help you save time, reduce costs,
maximize efficiency and open up much needed space in your data center.
It takes the complexity out of cable management, and optimizes the
performance of your data center floor space, racks and electronics.

FEATURES

• 

Reduce SAN switch cabling volume by up to 80%

• 

Implement high-density deployment with fewer
cabinet or infrastructure upgrades

• 

Minimize footprint - no additional front vertical, side,
or horizontal cable management devices

• 

Minimize cable mass and slack management using
linecard-optimized hydra assemblies

• 

Speed up deployments and reduce connection errors
with color-coded and keyed connections

More information on TE's SAM solution can be found at www.datacenteragility.com

Five Simple Components

ORDERING INFORMATION 

Product Description

Part Number

Rack Mount Patch Enclosure, 2RU MPO Secure

1553761-1

SAM Far End Enclosure, 1RU MPO to Quad LC

32-Port

48-Port

   OM3 (850 nm LO 50 

µ

m) Multimode

1553533-2

1553533-1

   Singlemode

1553657-2

1553657-1

SAM MPO Hydra Cable Assemblies

SAM Far End Enclosure

SAM Hydra

Q3000 SAM Blade

SAM Rack Mount Optical Fiber Enclosure

SAM Rack Mount Optical Fiber Enclosure

(Pro-E image)

Sc1_Fiber_04_StorageManag_v1.indd   103

12/7/12   11:48 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Storage Area Management (SAN Fiber Channel Management) 

1-104

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13  313948AE

FIBER

Product Description

Fiber/ Port Count

Front/ Rear Connector

Part Number

Q3000 SAM Blades

   Q3000 SAM Blade OM3/OM4

32/16

Duplex LC/MPO

QUFB-32FDLCMM4HR

   Q3000 SAM Blade Singlemode

32/16

Duplex LC/MPO

QUFB-32FDLCMSMHR

Product Description

Coupling Adaptor/Interface

Part Number

SAM MPO Adaptor Plates

2111481-1

   Adaptor Plate

Blank with Cable Management

SAM System Miscellaneous Components

1553658-1

   Cable Management Bracket Kit

ORDERING INFORMATION

Q3000 SAM Blades

FEATURES

• Replaces SAM Far End Enclosures

• Compatible with standard Q3000 frame 

• Maintains port similarity with switches and 

SAM MPO linecard kits

• Each blade supports two SAM trunks

• 16 LC duplex ports (32 fibers) per 1/2 RU blade

• OM3/OM4 and OS2 versions

• Fully pre-assembled and pre-tested

Q3000 SAM Blade

Adaptor Plates

Sc1_Fiber_04_StorageManag_v1.indd   104

12/18/12   1:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Storage Area Management (SAN Fiber Channel Management) 

1-105

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

FIBER

Part Number

Product Description

Plates Number

Hydras

Kit

SAM MPO Linecard Kits (Kit includes Plates and Hydras)

16-Port Kit

OM3 (850 nm LO 50

µ

m) Multimode

2193050-1

1553608-1, 1553609-1

2193057-1

Singlemode

2193050-1

1553635-1, 1553636-1

2193058-1

32-Port Kit

16 Gigabit SAM Kit

2111648-1

2111649-1, 2111649-2, 2111650-1, 2111650-2

2111651-1

OM3 (850 nm LO 50

µ

m) Multimode

2193051-1

1553608-1, 1553608-2, 1553609-1, 1553609-2

2193057-2

Singlemode

2193051-1

1553635-1, 1553635-2, 1553636-1, 1553636-2

2193058-2

48-Port Kit

OM3 (850 nm LO 50

µ

m) Multimode

2193052-1

1553527-1, 1553527-2, 1553528-1, 
1553528-2, 1553529-1, 1553529-2

2193057-3

Singlemode

2193052-1

1553676-1, 1553676-2, 1553677-1, 
1553677-2, 1553678-1, 1553678-2

2193057-3

64-Port Kit

OM3 (850 nm LO 50

µ

m) Multimode

2193016-1

2193045-1, 2193045-2, 2193046-1, 2193046-2, 
2193047-1, 2193047-2, 2193048-1, 2193048-2

2193057-4

Singlemode

SAM Hydra

2193053-1, 2193053-2, 2193054-1, 2193054-2, 
2193055-1, 2193055-2, 2193056-1, 2193056-2

2193058-4

SAM MPO Cable Assemblies

End A

End B

Length

Part Number

OM3 (850 nm LO 50 

µ

m) Multimode

MPO

MPO

3 m (10

'

)

1553534-1

6 m (20

'

)

1553534-2

9 m (30

'

)

1553534-3

12 m (40

'

)

1553534-4

15 m (50

'

)

1553534-5

18 m (60

'

)

1553534-6

21 m (70

'

)

1553534-7

24 m (80

'

)

1553534-8

27 m ( 90

'

)

1553534-9

30 m ( 100

'

)

1-1553534-0

Singlemode

MPO

MPO

3 m (10

'

)

1553640-1

6 m (20

'

)

1553640-2

9 m (30

'

)

1553640-3

12 m (40

'

)

1553640-4

15 m (50

'

)

1553640-5

18 m (60

'

)

1553640-6

21 m (70

'

)

1553640-7

24 m (80

'

)

1553640-8

27 m ( 90

'

)

1553640-9

30 m ( 100

'

)

1-1553640-0

ORDERING INFORMATION CONTINUED

SAM MPO Cable Assemblies

SAM Hydra

Sc1_Fiber_04_StorageManag_v1.indd   105

12/7/12   11:48 AM

Tyco-catalog-AMP-2013-html.html
background image

1-106

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

 Fiber

 Optical LAN Solution Supporting PON Technologies

2

3

4

7

6

5

Rapid Indoor Fiber 

Distribution Hub (iFDH) with 

"preconnectorized" stubs

2

Rapid Fiber Distribution 

Terminal (FDT) with 

"preconnectorized" stubs

3

Ethernet Cable

6

1

RealFlex MDU Dop Cables

4

Wall Plate

7

1

TFP Series Rack Mount 

Fiber Panels

Fiber Patch Cord

5

As optical fi ber moves closer to end users, rapid changes are underway
in both the data center and the equipment closet. As a result, new
installation and maintenance techniques are being employed within
enterprise applications. Passive Optical Network (PON) applications
are now being deployed. Fiber is no longer limited to just access
equipment. Fiber connectivity to a single user is a reality.

TE Connectivity off ers a complete, end-to-end PON infrastructure
solution called Optical LAN Solution (OLS). From the data center
to the desktop, our customers have tapped the experience and
innovation of TE to build their PON networks. TE’s suite of
end-to-end connectivity solutions is truly comprehensive. This
ordering guide highlights the most commonly used components
that feature fi eld-proven attributes that save time, money, and can
help improve customer satisfaction.

The diagram below highlights a PON deployment using the
TE OLS solution. Each number corresponds to a specifi c innovative
TE solution.

More information on TE's OLS solution can be found at
www.PONsource.com.

Router

OLT

TFP Fiber Panel

FDH - Fiber Distribution Hub

FDT 

Fiber Distribution Terminal

Fiber Wall Plate

ONT

Optional Component Confi gurations

Fiber Splitter Box (FSB)

Video WDM

2

3

4

7

6

5

Rapid Indoor Fiber 

Distribution Hub (iFDH) with 

"preconnectorized" stubs

2

Rapid Fiber Distribution 

Terminal (FDT) with 

"preconnectorized" stubs

3

Ethernet Cable

6

1

RealFlex MDU Dop Cables

4

Wall Plate

7

1

TFP Series Rack Mount 

Fiber Panels

Fiber Patch Cord

5

End-to-End Network Infrastructure

Sc1_Fiber_05_OpticalLAN_v1.indd   106

12/11/12   4:05 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-107

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

TFP Fiber Panels

TE‘s TrueNet Fiber Panels (TFP) combine the unique features of vertical cable
guides, patented angle-left/angle-right adapters, and plug-and-play angled
cassettes, which offer bend radius protection, intuitive routing, and easy
connector access. The TFP series can be ordered in one, two, or five rack-unit
sizes to fit your unique needs. Designed for rack mounting in the equipment
distribution area, the TFP’s modularity, functionality and density make it ideal
for mounting in close proximity to the enterprise aggregation switch (OLT). The
cassettes snap into place effortlessly and come from the factory pre-labeled with
simple installation instructions.

The TFP panels are ideal for the interconnection points between the active OLT
and the iFDH if it is co-located in the same building as the OLS deployment. The
TFP cassettes are equipped with MPO adapters on the back allowing a simple
plug-in from the iFDH feeder cable.

TFP Angled-Left Cassette

1RU TFP Panel

ORDERING INFORMATION

Description

Height

Part Number

Termination Only Rack- or Cabinet-Mount 
Panel; 

Black; T-handle latch close

1RU empty panel, accommodates 2 plug-and-play cassettes

1.75"

TFP-1TT00-000B

2RU empty panel, accommodates 4 plug-and-play cassettes

3.50"

TFP-2TT00-000B

4RU empty panel, accommodates 8 plug-and-play cassettes

7.00"

TFP-4TT00-000B

5RU empty panel, accommodates 12 plug-and-play cassettes

8.75"

TFP-5TT00-000B

Plug-and-Play Cassettes

** To maintain consistency with fiber 

distribution hubs and terminals order  
SC/APC cassettes for TFP panel.

12 fiber cassettes**; 12 SC/APC 
singlemode adapters

Angle LEFT cassette

TFP-12MPLSA1

Angle RIGHT cassette

TFP-12MPRSA1

Recommended Accessories

3RU horizontal glide cable manager; with integrated slack storage spools

ADCCMHIBS-3U

Adapter plates

TFP blank plate

TFP-00AP00

TFP SC/APC adapter plate right 

TFP-12APRA1

TFP SC/APC adapter plate left

TFP-12APLA1

FEATURES

• 

Eliminates the need for on-site fiber terminations, which means more rapid deployments

• 

Incorporates angle left/angle right adapters to ensure proper bend radius

• 

Uses the same 1, 2, 4 and 5 rack unit standard TFP chassis which simplifies ordering

• 

TFP cassettes equipped with MPO adapters on back allow simple plug-in from iFDH feeder cables

Sc1_Fiber_05_OpticalLAN_v1.indd   107

12/11/12   4:05 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-108

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Rapid Fiber Distribution Hub (iFDH) 

TE‘s rapid fiber distribution hub organizes and administers optical fiber cables 
and passive optical splitters for enterprise PON applications. The enclosures 
support plug-and-play termination with a cross-connect/interconnect interface 
that makes installation, maintenance, and changes faster and easier. The 
RapidReel feeder cable speeds up installation time and conveniently stores 
slack inside the iFDH.

FEATURES

• 

Support plug-and-play termination 

• 

Can be either wall or rack mounted with the hardware provided

• 

Traditional swing-frame design allows superior rear access

• 

Includes RapidReel feeder cable

• 

Designed to meet NEMA-12 requirements

• 

UL 1863 Listed

Rapid Indoor FDH 

with Easy Access to 

Built-in MPO Panel

Rapid Indoor FDH 

front panel

ORDERING INFORMATION

Description

Feeder Cable Type

Distribution Type

Feeder Stub Length

Part Number

72-Port 

with 9 splitter ports

12-fiber plenum

6 MPO adapters

100’

OLH-MK072J00M0MKCA

250’

OLH-MK072J00M0MKEA

500’

OLH-MK072J00M0MKBA

72-Port Empty Hub

No feeder cable**

OLH-MK072J00M0M000

288-Port 

with 18 splitter ports

24-fiber plenum

24 MPO adapters

100’

OLH-MM288J00M0MKCB

250’

OLH-MM288J00M0MKEB

500’

OLH-MM288J00M0MKBB

288-Port Empty Hub

No feeder cable**

OLH-MM288J00M0M000

432-Port 

with 22 splitter ports

24-fiber plenum

36 MPO adapters

100’

OLH-MN432J00M0MKCB

250’

OLH-MN432J00M0MKEB

500’

OLH-MN432J00M0MKBB

432-Port Empty Hub

No feeder cable**

OLH-MM 432J00M0M000

*Note: Splitters are purchased separately; ordering information on the following page.
**See page 1-114 for MPO-MPO cable assemblies.

Sc1_Fiber_05_OpticalLAN_v1.indd   108

12/11/12   4:05 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-109

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Plug-and-play Splitter

FMT Rack Mounted 

Splitter Panel

1RU Splitter Drawer

ORDERING INFORMATION

Description

Feeder Cable Type

Distribution Type

Feeder Stub Length

Part Number

72-Port 

with 9 splitter ports

12-fiber plenum

6 MPO adapters

100’

OLH-MK072J00M0MKCA

250’

OLH-MK072J00M0MKEA

500’

OLH-MK072J00M0MKBA

72-Port Empty Hub

No feeder cable**

OLH-MK072J00M0M000

288-Port 

with 18 splitter ports

24-fiber plenum

24 MPO adapters

100’

OLH-MM288J00M0MKCB

250’

OLH-MM288J00M0MKEB

500’

OLH-MM288J00M0MKBB

288-Port Empty Hub

No feeder cable**

OLH-MM288J00M0M000

432-Port 

with 22 splitter ports

24-fiber plenum

36 MPO adapters

100’

OLH-MN432J00M0MKCB

250’

OLH-MN432J00M0MKEB

500’

OLH-MN432J00M0MKBB

432-Port Empty Hub

No feeder cable**

OLH-MM 432J00M0M000

*Note: Splitters are purchased separately; ordering information on the following page.
**See page 1-114 for MPO-MPO cable assemblies.

Splitter Panel

Cable Manager

Mini Plug-and-Play Splitter Modules 

TE‘s Mini Plug-and-Play Splitter Modules support centralized splitting architectures. 
The modules are available in a wide range of split ratios and are used in TE‘s iFDH 
OLH series cabinets. The rugged packaging is built for high performance, while the 
true plug-and-play design reduces installation time. 

FEATURES

• 

Bend-optimized fiber and ruggedized extreme temperature cabling 

• 

Operating temperature range -55° to +85° C 

• 

Superior loss performance at 1490 and 1550 wavelengths

• 

Easy to insert and remove without affecting adjacent splitters

• 

Allows pass-through of up to 2 fibers per splitter

• 

UL 1863 Listed

ORDERING INFORMATION

Description

Part Number

Optical Splitter Module 

Angled SC Pigtails
Used with iFDH, FSB, Splitter 
drawer, and Splitter Panels 

1 x 32 splitter

OLS-MPP13266

1 x 16 splitter

OLS-MPP11666

1 x 8 splitter

OLS-MPP10866

2 x 32 splitter

OLS-MPP12A66

1RU FMT Rack Mount Splitter

1 x 32 splitter

OPS-FMTSP-AJJ01 

2 x 32 splitter

OPS-FMTSP-GJJ01 

Rack Mount splitter panel

OPS-MPPRACKMT24

Cable Manager

OPS-MPPRACKMTCM

Parking Lot

OCB-ACC200-PKLT3

Rack Mount Splitter Drawer

OPS-MPPACCRMPNL

Sc1_Fiber_05_OpticalLAN_v1.indd   109

12/11/12   4:05 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-110

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Rapid Fiber Distribution Terminal

TE‘s Rapid Fiber Distribution Terminal (FDT) provides a compact, NEMA-12 rated 
solution for connecting optical fiber cables within enterprise environments and serves 
as the distribution point between the Rapid iFDH and the user area. It eliminates the 
need for splice cases and separate cable assemblies by integrating the RapidReel 
cable payout system. Use of factory terminated and tested MPO connectors instead 
of splicing provide a plug-and-play environment that reduces labor costs and speeds 
project completion. The Rapid FDT provides a lockable consolidation point and localized 
patch field, allowing for precise cable length customization in the field, while reducing 
overall cable volume and simplifying routing from the FDH to the user area. The iFDT‘s 
compact footprint enables it to be placed under raised floors or wall mounted.

FEATURES

• 

Built-in RapidReel technology allows for easy payoff of MPO stub

• 

Patented break-away spool flanges reduce slack storage size to within the 
enclosures footprint

• 

Utilizes reduced bend radius fiber

• 

UL 1863 listed

Rapid FDT

using slider adapter packs

Rapid FDT

ORDERING INFORMATION

Description

Stub

Feeder Stub Length

Part Number

12-fiber 

Loose tube plenum cable

MPO

100’

OLR-SJ12J00D1002A

200’

OLR-SJ12J00D2002A

300’

OLR-SJ12J00D3002A

24-fiber 

Loose tube plenum cable

100’

OLR-SJ24J00D1002A

200’

OLR-SJ24J00D2002A

300’

OLR-SJ24J00D3002A

Mini-RDT

200'

ODT-SM12J00D0619A

300'

ODT-SM12J00D0929A

400'

ODT-SM12J00D1229A

500'

ODT-SM12J00D1529A

*Note: Other cable lengths available. Contact your local TE sales engineer.

Sc1_Fiber_05_OpticalLAN_v1.indd   110

12/11/12   4:05 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-111

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Wall Boxes

TE’s fiber splitter boxes (FSB) are mini fiber distribution hubs that can be used 
for plug-and-play (PNP) or fusion splice applications.

When used as a plug and play box, they are ideal for uses such as lower 
count floors or buildings, extra capacity requirements beyond the standard 
fiber distribution hub (FDH), and when localized splitting or physical path 
redundancy (using a 2x32 split) is desired. 

The same box can also be used to extend services beyond the primary building 
to other smaller buildings with limited users on the campus. In this type of 
application, the FSB is typically spliced to the OSP fiber cable connecting the 
buildings and would offer the optical splitting required to provide PON services 
to the second building. 

These wall boxes provide a small footprint for splitting, terminating, and 
splicing. FSBs accept standard plug-and-play splitters and can be easily added 
after the wall box has been installed. FSBs accommodate 1x8, 1x16, 1x32, and 
2x32 splitters. Wall mounting provides significant space savings and the unique 
swing frame design allows for easy access to the back section of the wall box.

FEATURES AND BENEFITS

• 

Dual hinge design creates separation between rear splitter section and 
front customer side access

• 

Splitters can be easily installed after wall box installation allowing for 
separate purchase

• 

Provides up to 32 customer access ports per splitter

• 

Dual hinge provides small footprint on the wall while maintaining excellent 
hand access to connectors

• 

Accepts standard PNP splitter modules (same as iFDH)

• 

UL 1863 listed

FSB-32 Indoor Enclosure

ORDERING INFORMATION

Description

Part Number

FSB-32 Indoor Enclosure;  

with SC/APC adapters, 32-fiber distribution

No splitters, no splice trays

OSB-SBJ032000000

No splitters, with heat shrink splice trays

OSB-SBJ232000000

(1) 1x32 splitter installed, no splice trays

OSB-SBJ032A10000

(1) 1x32 splitter installed, with heat shrink splice trays OSB-SBJ232A10000

2 x 32 splitter installed, no splice trays

OSB-SBJ032G10000

2 x 32 splitter installed, with heat shrink splice trays

OSB-SBJ232G10000

Optical Splitter Module - Angled SC Pigtails

1x32 splitter

OLS-MPP13266

1x16 splitter

OLS-MPP11666

1x8 splitter

OLS-MPP10866

2x32 splitter

OLS-MPP12A66

Sc1_Fiber_05_OpticalLAN_v1.indd   111

12/11/12   4:05 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-112

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Stapled 3 mm Drop Cable

Simplex Drop Cables 

ORDERING INFORMATION 

Description

Length in Meters Part Number

SCAPC-SCAPC Plenum Ivory

3 (10')

PAT-6C6C-PSIG003M

8 (25')

PAT-6C6C-PSIG008M

16 (50')

PAT-6C6C-PSIG016M

23 (75')

PAT-6C6C-PSIG023M

31 (100')

PAT-6C6C-PSIG031M

38 (125')

PAT-6C6C-PSIG038M

46 (150')

PAT-6C6C-PSIG046M

SCAPC-SCUPC Plenum Ivory

3 (10')

PAT-SC6C-PSIG003M

8 (25')

PAT-SC6C-PSIG008M

16 (50')

PAT-SC6C-PSIG016M

23 (75')

PAT-SC6C-PSIG023M

31 (100')

PAT-SC6C-PSIG031M

38 (125')

PAT-SC6C-PSIG038M

46 (150')

PAT-SC6C-PSIG046M

Additional configurations and lengths are available; contact TE for assistance.

Sc1_Fiber_05_OpticalLAN_v1.indd   112

12/11/12   4:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-113

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Optical Fiber Cables 

TE reduced bend radius singlemode patch cords are used to connect the user area 
to the Rapid FDT or when connecting the ONT to the wall plate at the user end of 
the PON. With nearly 40 years of fiber cable manufacturing experience, TE offers 
a complete family of high performance cable and related products. 

TE‘s singlemode reduced bend radius patch cords have a bend radius of 7.5 mm 
and are backwards compatible with standard singlemode fiber. TE offers ultra 
physical contact (UPC) or angled physical contact (APC) SC connector styles. TE 
maintains tight tolerances regarding the geometry and concentricity of the ferrule 
to maintain low insertion loss values. All patch cords undergo stringent testing for 
both insertion loss and return loss at the factory before shipment to ensure that a 
high quality product is delivered.

SC Angled Polish

SC Ultra Polish

ORDERING INFORMATION 

Description

Length in Meters Part Number

SCAPC-SCAPC Yellow

3 (10')

PAT-6C6C-PS0G003M

8 (25')

PAT-6C6C-PS0G008M

16 (50')

PAT-6C6C-PS0G016M

23 (75')

PAT-6C6C-PS0G023M

31 (100')

PAT-6C6C-PS0G031M

38 (125')

PAT-6C6C-PS0G038M

46 (150')

PAT-6C6C-PS0G046M

SCAPC-SCUPC Yellow

3 (10')

PAT-SC6C-PS0G003M

8 (25')

PAT-SC6C-PS0G008M

16 (50')

PAT-SC6C-PS0G016M

23 (75')

PAT-SC6C-PS0G023M

31 (100')

PAT-SC6C-PS0G031M

38 (125')

PAT-SC6C-PS0G038M

46 (150')

PAT-SC6C-PS0G046M

Additional configurations and lengths are available; contact TE for assistance.

Sc1_Fiber_05_OpticalLAN_v1.indd   113

12/11/12   4:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-114

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

MPO-MPO Cable Assemblies 

ORDERING INFORMATION 

Description

12-Fiber 3 mm Singlemode Reduced Bend 
Radius Plenum Cable

Length in Feet

Part Number

12-Fiber MPO-MPO

100'

MPA-NCNCJ50100F-NN

200'

MPA-NCNCJ50200F-NN

300'

MPA-NCNCJ50300F-NN

400'

MPA-NCNCJ50400F-NN

500'

MPA-NCNCJ50500F-NN

600'

MPA-NCNCJ50600F-NN

750'

MPA-NCNCJ50750F-NN

1000'

MPA-NCNCJ50305M-NN

24-Fiber Zip MPO-MPO

100'

MPA-NCNCZ50100F-SS

200'

MPA-NCNCZ50200F-SS

300'

MPA-NCNCZ50300F-SS

400'

MPA-NCNCZ50400F-SS

500'

MPA-NCNCZ50500F-SS

600'

MPA-NCNCZ50600F-SS

750'

MPA-NCNCZ50750F-SS

1000'

MPA-NCNCJ50305M-SS

Additional configurations and lengths are available; contact TE for assistance.

Singlemode Reduced Bend Radius Multifiber Cable Assemblies 

ORDERING INFORMATION 

Description

12-Fiber 3 mm Singlemode Reduced Bend 
Radius Plenum Cable

Length in Feet

Part Number

MPO to SC/APC

50'

MPA-NC6CJ50050F-NN

100'

MPA-NC6CJ50100F-NN

200'

MPA-NC6CJ50200F-NN

300'

MPA-NC6CJ50300F-NN

MPO to SC/UPC

50'

MPA-NCSCJ50050F-NN

100'

MPA-NCSCJ50100F-NN

200'

MPA-NCSCJ50200F-NN

300'

MPA-NCSCJ50300F-NN

MPO to ST/UPC

50'

MPA-NCTCJ50050F-NN

100'

MPA-NCTCJ50100F-NN

200'

MPA-NCTCJ50200F-NN

300'

MPA-NCTCJ50300F-NN

Additional configurations and lengths are available; contact TE for assistance.

Sc1_Fiber_05_OpticalLAN_v1.indd   114

12/11/12   4:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-115

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Armored Cable

Our Secured Armored Optical LAN Solution allows high-security customers to
have confi dence that their optical network will be secure when deployed. The
secured OLS platform uses TE Connectivity’s interlocking armored cable that
provides a tamper-proof protection cable connecting to a secured junction box
that can be mounted on the ceiling or in a sub fl oor. The junction box allows up to
four input cables with a maximum of 72 fi bers. The drop side of the junction box
will allow up to 72 armored fi bers to be run to secured user facilities connecting
to a user box that can be mounted either under or on top of the desktop. The
ONT box off ers access separation for authorized network personnel only and
simple access from a locked door allowing approved user access with issued key.

ORDERING INFORMATION 

Description

Part Number

Armored cable assemblies

6-fi ber, SM Interlocking Aluminum Armor

 4-1777121-7

12-fi ber, SM Interlocking Aluminum Armor

 4-1777117-7

24-fi ber, SM Interlocking Aluminum Armor

 7-1553420-3

72-fi ber, SM Interlocking Aluminum Armor

 4-1777124-7

Colored, keyed, SECURE cable assemblies and other armored confi gurations are available. 
Contact your local TE Connectivity Sales Engineer.

Color coding of armored plant is available

Secure Data

Center

Junction

Box

Junction Box

on Desktop

Sc1_Fiber_05_OpticalLAN_v1.indd   115

12/11/12   4:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-116

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Category 5e Patch Cords 

TE‘s TrueNet patch cord cables are available in Category 5e, 6, or augmented Cat 6 and  
in a variety of lengths and colors for interconnecting output of ONT to user's computer.

ORDERING INFORMATION 

Description

Cable Color

Part Number

RJ45 plug to RJ45 plug, T568B  

Quantity: 1
Wired straight through

RJ45 plug  

(T568B)

RJ45 plug  

(T568B)

White

TCPC-5ESUVB-WTxxF

Red

TCPC-5ESUVB-RDxxF

Blue

TCPC-5ESUVB-BLxxF

Green

TCPC-5ESUVB-GNxxF

Yellow

TCPC-5ESUVB-YLxxF

Gray

TCPC-5ESUVB-GYxxF

RJ45 plug to RJ45 plug, T568A  

Quantity: 1
Wired straight through

RJ45 plug 

(T568A)

RJ45 plug 

(T568A)

White

TCPC-5ESUVA-WTxxF

Red

TCPC-5ESUVA-RDxxF

Blue

TCPC-5ESUVA-BLxxF

Green

TCPC-5ESUVAGNxxF

Yellow

TCPC-5ESUVA-YLxxF

Gray

TCPC-5ESUVA-GYxxF

* Replace xx with:  

04 = 4’ 

10 = 10’ 

25 = 25’ 

 

 

07 = 7’ 

15 = 15’ 

50 = 50’

Contact TE for additional cable colors and lengths.

Security Key Plug

FEATURES

• 

Works with standard RJ45 jacks 

• 

Prevents unauthorized port connections

• 

Prevents disconnection from active devices

• 

Lock to RJ45 modular jacks

• 

Can be used in public areas or conference rooms

• 

1871456-1 key/lock pairs are randomly selected from 100 different key 
numbers (numbered 800-899)

• 

1871456-2, -3, and -4 use specific reserved key/lock pair number 456A

• 

RoHS compliant

Security Key Plug

Category 5e Patch Cords

Sc1_Fiber_05_OpticalLAN_v1.indd   116

12/11/12   4:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-117

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Security Key Patch Cord

FEATURES

• 

Works with standard RJ45 ports

• 

Prevents disconnection from active devices

• 

Prevents unauthorized disconnection

• 

Can be used for secure connections (e.g. server lines)

• 

Uses specifi c reserved key/lock pair number 456A (two keys included)

• 

RoHS compliant

• 

Category 6 patch cables are backward compatible with Category 5e components

• 

Security patch cord color:

Cat 6: black

Cat 6A F/UTP: blue

ORDERING INFORMATION

Category

Length

Locks on Both Ends

Locks on one End

Cat 6 Unshielded

1' (0.30 m)

 2111179-1

 2111225-1

2' (0.61 m)

 2111179-2

 2111225-2

3' (0.91 m)

 2111179-3

 2111225-3

4' (1.22 m)

 2111179-4

 2111225-4

5' (1.52 m)

 2111179-5

 2111225-5

6' (1.83 m)

 2111179-6

 2111225-6

7' (2.13 m)

 2111179-7

 2111225-7

8' (2.44 m)

 2111179-8

 2111225-8

9' (2.74 m)

 2111179-9

 2111225-9

10' (3.05 m)

 1-2111179-0

 1-2111225-0

12' (3.66 m)

 1-2111179-2

 1-2111225-2

14' (4.27 m)

 1-2111179-4

 1-2111225-4

16' (4.88 m)

 1-2111179-6

 1-2111225-6

18' (5.49 m)

 1-2111179-8

 1-2111225-8

20' (6.10 m)

 2-2111179-0

 2-2111225-0

Cat 6A Shielded

1' (0.30 m)

 2111190-1

 2111236-1

2' (0.61 m)

 2111190-2

 2111236-2

3' (0.91 m)

 2111190-3

 2111236-3

4' (1.22 m)

 2111190-4

 2111236-4

5' (1.52 m)

 2111190-5

 2111236-5

6' (1.83 m)

 2111190-6

 2111236-6

7' (2.13 m)

 2111190-7

 2111236-7

8' (2.44 m)

 2111190-8

 2111236-8

9' (2.74 m)

 2111190-9

 2111236-9

10' (3.05 m)

 1-2111190-0

 1-2111236-0

12' (3.66 m)

 1-2111190-2

 1-2111236-2

14' (4.27 m)

 1-2111190-4

 1-2111236-4

16' (4.88 m)

 1-2111190-6

 1-2111236-6

18' (5.49 m)

 1-2111190-8

 1-2111236-8

20' (6.10 m)

 2-2111190-0

 2-2111236-0

Cat 6A Patch Cord

Cat 6 Patch Cord

Sc1_Fiber_05_OpticalLAN_v1.indd   117

12/11/12   4:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-118

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Category 6 Patch Cords 

TE‘s TrueNet Category 6 patch cords are available in a variety of lengths and colors 
for interconnecting output of ONT to a user’s computer.

ORDERING INFORMATION 

Description

Cable Color

Part Number

RJ45 plug to RJ45 plug, T568B Quantity: 1
Wired straight through

RJ45 plug 

(T568B)

RJ45 plug 

(T568B)

Black

 TCPC-6RUVB-BKxxF

Blue

 TCPC-6RUVB-BLxxF

Green

 TCPC-6RUVB-GNxxF

Gray

 TCPC-6RUVB-GYxxF

Red

 TCPC-6RUVB-RDxxF

White

 TCPC-6RUVB-WTxxF

Yellow

 TCPC-6RUVB-YLxxF

RJ45 plug to RJ45 plug, T568A Quantity: 1
Wired straight through

RJ45 plug 

(T568A)

RJ45 plug 

(T568A)

Blue

 TCPC-6RUVA-BLxxF

Green

 TCPC-6RUVA-GNxxF

Gray

 TCPC-6RUVA-GYxxF

Red

 TCPC-6RUVA-RDxxF

White

 TCPC-6RUVA-WTxxF

Yellow

 TCPC-6RUVA-YLxxF

RJ45 to RJ45 Patch Cord

Color

Part Number

568B wiring

White

 TCPC-6ARFVB-WTxxF

Red

 TCPC-6ARFVB-RDxxF

Blue

 TCPC-6ARFVB-BLxxF

Yellow

 TCPC-6ARFVB-YLxxF

Green

 TCPC-6ARFVB-GNxxF

Gray

 TCPC-6ARFVB-GYxxF

568A wiring

White

 TCPC-6ARFVA-WTxxF

Red

 TCPC-6ARFVA-RDxxF

Blue

 TCPC-6ARFVA-BLxxF

Yellow

 TCPC-6ARFVA-YLxxF

Green

 TCPC-6ARFVA-GNxxF

Gray

 TCPC-6ARFVA-GYxxF

* Replace XX with: 

04 = 4’ 

10 = 10’ 

25 = 25’

07 = 7’ 

15 = 15’ 

50 = 50’

Contact TE for additional cable colors and lengths.

Category 6A Patch Cords 

OE‘s TrueNet Category 6A patch cords are available in a variety of lengths and colors 
for interconnecting output of ONT to a user’s computer. 

Category 6 Patch Cord

Category 6A Patch Cord.

RJ45 plug 

(T568B)

RJ45 plug 

(T568B)

RJ45 plug 

(T568A)

RJ45 plug 

(T568A)

Sc1_Fiber_05_OpticalLAN_v1.indd   118

12/11/12   4:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-119

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

ORDERING INFORMATION

Description

Figure

Color

Part Number

Angled Faceplates

2-port

A

Almond

1375155-1

4-port

B

Almond

406185-1

Inserts

LC Duplex couplers

Singlemode APC

C

Green

1933286-3

Singlemode

D

Blue

1933286-4

SC Simplex coupler; singlemode

E

Green

1499836-9 

F-Connector coupler, 2 GHz

F

Almond

1499855-1

Blank

G

Almond

1116412-1

Angled Faceplates

FEATURES

• 

Accepts all AMP-TWIST jacks, SL series jacks, and SL series inserts

• 

Angled connector exits

• 

Protects connections

• 

Allows closer furniture placement

Figure A

Figure B

Figure F

Figure D

Figure G

Figure E

Figure C

Sc1_Fiber_05_OpticalLAN_v1.indd   119

12/11/12   4:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-120

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

SL Series Faceplates

FEATURES

• 

Single gang and double gang, single-sided faceplates accept three 1 unit
or two 1.5 unit SL series modules

• 

Double gang, double-sided faceplates accept three 1 unit or two 1.5 unit
SL series modules on each side

• 

Front-loading modules eliminate need to remove faceplates from wall for
changes or repairs

• 

Double gang, double-sided SL series faceplates:

– Dimensions (DxWxH): 0.675" x 4.490" x 4.540"

– For use with openings a minimum of 2.81" x 3.59"

(not suitable for mud rings/device covers)

ORDERING INFORMATION 

Description

Width

Figure

Part Number

SL Series Faceplates 

Almond

Single Gang

Single-sided

A

 1339118-1

Double Gang

Single-sided

B

 1339119-1

Double-sided

C

 1479486-1

Figure A

Figure B

Figure C

ORDERING INFORMATION 

Description

Figure

Part Number

4-Port

A

 1479946-1

6-Port

B

 1479815-1

HIDEAWAY Multimedia Outlets

FEATURES

• 

Accepts the following (see table for detailed load information):

– Shielded and unshielded SL series jacks

– AMP-TWIST jacks

– SL series inserts

• 

Fits single and double gang electrical J-boxes

• 

Features “invisible” icon holes which remain hidden until used

• 

Features integral tabs for easy fi ber loop management

• 

Breakaway tabs in duplex fi ber coupler cut outs allow HIDEAWAY outlets
to accept “fl angless” SECURE LC duplex, standard LC duplex, or hybrid LC
duplex couplers with retention clips (break out the tabs when using standard
duplex couplers)

Figure A

Figure B

Sc1_Fiber_05_OpticalLAN_v1.indd   120

12/11/12   4:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-121

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

ORDERING INFORMATION

 

Description

Included Faceplate

Part Number

HIDEOUT Outlet Kit 

Almond

Screw-on

 503997-1

Snap-on

 503999-1

HIDEOUT Outlets

FEATURES

• 

Double gang box with single gang cover recommended

• 

May not fi t all single gang boxes

• 

Hides and protects cable connections

• 

Feeds from bottom to allow fl ush furniture placement

• 

Fits standard electrical boxes

• 

Each kit includes sub-plate, faceplate, adhesive labels, cable ties, and mounting
screws. Media modules and icons must be ordered separately. Faceplates are plastic
except for the stainless steel version

• 

Accepts the following (see table for detailed load information):

Shielded or unshielded SL series jacks

Unshielded 110Connect jacks

SL Series inserts

• 

Shielded SL series jacks work in bottom row of faceplate only

Screw-on Cover

Snap-on Cover

Sc1_Fiber_05_OpticalLAN_v1.indd   121

12/11/12   4:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-122

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Figure A

Figure B

ORDERING INFORMATION

Description

Figure

Color

Part Number

Power Monument; 

15 Amp

A

Black

556222-3

Voice/Data Monument Empty Housing; 

requires FLEX-MODE faceplate

B

Black

1116360-3

Flex-Mode flush faceplace;

 2-port

C

Black

558106-1

SL series; 

4-port

D

Black

1933134-1

Desktop Monuments

FEATURES

• 

Power monuments:

Provide access to duplex power outlet at the desktop

Eliminates the need to feed power cables behind or through desks

Supplied with an 8' (2.4 m), 3-prong power cord for connection to
existing electrical outlets

• 

Voice/data monuments:

– Accepts standard FLEX-MODE faceplates

Horizontal cabling can be connected directly to SL series modular jacks
(recommended for Category 5e applications)

• 

Attach to any desktop from 0.90" - 1.78" (22.9 mm - 45.2 mm)

• 

No special tools required to attach, simply place the monument onto the
edge of the desktop and tighten the integrated thumb screw

• 

UL listed and CSA certified

Figure C

Figure D

Sc1_Fiber_05_OpticalLAN_v1.indd   122

12/11/12   4:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Optical LAN Solution Supporting PON Technologies

1-123

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

Transition Cable Assembly

S-One Box

Concealed ONT Kit

ORDERING INFORMATION

Description

Part Number

Concealed ONT Kits

Kit is used when concealing the ONT inside a S-One box 
and extends the Category 6 cabling to the wall plate.

 OTN-OLSSBKT-2

6-Port Concealed ONT Kit

Kit includes:
(1) 6-port surface mount box
(4) Category 6 jacks
(4) Category 6 patch cords; 1 foot
(1) F-81 RF video adapter (1) SC/APC adapter

4-Port Concealed ONT Kit

Kit includes:
(1) 4-port surface mount box
(4) Category 6 jacks
(4) Category 6 patch cords; 1 foot

 OTN-0LSSBKT-1

Consolidation Point Transition Cable Assemblies

• 

Ideal for shared ONT applications

• 

Form connections between remote/shared ONTs and the work area

• 

Compatible with all SL series faceplates

• 

Factory-assembled and tested

• 

Save time and money on moves, adds and changes

• 

Lead-free (no heavy metals)

• 

Gray cable jacket

ORDERING INFORMATION

End A

End B

Length

Plenum (CMP) T568A Plenum (CMP) T568B

Category 5e Modular Plug

SL Series Category 
5e Modular Jack

20'

 219174-1

  219175-1

30'

 219174-2

 219175-2

40'

 219174-3

 219175-3

50'

 219174-4

 219175-4

Sc1_Fiber_05_OpticalLAN_v1.indd   123

12/11/12   4:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-124

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

FIBER

Fiber Optic Accessories and Tooling

TE Connectivity's tool kits include all tools and consumables
necessary for fiber termination

• 

Universal toolkits for installing all LightCrimp PLUS connectors

• 

Includes tools for installing MT-RJ and MT-RJ SECURE jacks

• 

Includes all tools necessary to install epoxy/polish connectors

LightCrimp PLUS LC/SC and LightCrimp Splice
Termination Tool Kit

•  Includes all tools need for installing LightCrimp PLUS LC, 

LC SECURE, SC, and LightCrimp Splice

• 

Convenient carrying case

• 

Tool kit includes:

- Splice/Cable buff er holder

- PRO-CRIMPER III hand tool

- LC/SC/Splice die set

- Fiber cleaver

- 2.0 mm cable slitter

- Buff er stripper

- Cable jacket stripper

- Strength member shears

Tool Kit Compatibility Chart

Tool Kit Name

MT-RJ 

Jacks

MT-RJ 

SECURE Jacks

LightCrimp PLUS    LightCrimp 

Splice

Epoxy/Polish

Tool Kit

Part Number

**LC

SC

ST

LC

SC

ST

 LightCrimp PLUS Termination Tool Kit

X

X

X

 1553212-1

 LightCrimp PLUS No-epoxy/No-polish Universal Tool Kit

X

X

X

X

X

 1278118-4

LightCrimp PLUS No-epoxy/No-polish Universal Tool Kit

X

X

X

X

X

 1278118-5

 LightCrimp PLUS No-epoxy/No-polish LC and SC Tool Kit

X

X

 1754845-1

LightCrimp PLUS No-epoxy/No-polish LC and SC Tool Kit

X

X

 1754845-2

 LightCrimp PLUS No-epoxy/No-polish ST Tool Kit

X

 492697-1

LightCrimp PLUS No-epoxy/No-polish ST Tool Kit

X

 492697-2

 MT-RJ Jack Tool Kit

X

X

 1278346-1

X

X

 1278346-2

 Epoxy/Polish Tool Kits

X*

X

 503746-7

X*

X

 503746-1

*Note: Termination of LC Epoxy/Polish Connectors requires additional tools listed in this chapter.
**Note: Termination includes LC SECURE Connectors

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   124

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-125

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

FIBER

Tool Kit Compatibility Chart

Tool Kit Name

MT-RJ 

Jacks

MT-RJ 

SECURE Jacks

LightCrimp PLUS    LightCrimp 

Splice

Epoxy/Polish

Tool Kit

Part Number

**LC

SC

ST

LC

SC

ST

 LightCrimp PLUS Termination Tool Kit

X

X

X

 1553212-1

 LightCrimp PLUS No-epoxy/No-polish Universal Tool Kit

X

X

X

X

X

 1278118-4

LightCrimp PLUS No-epoxy/No-polish Universal Tool Kit

X

X

X

X

X

 1278118-5

 LightCrimp PLUS No-epoxy/No-polish LC and SC Tool Kit

X

X

 1754845-1

LightCrimp PLUS No-epoxy/No-polish LC and SC Tool Kit

X

X

 1754845-2

 LightCrimp PLUS No-epoxy/No-polish ST Tool Kit

X

 492697-1

LightCrimp PLUS No-epoxy/No-polish ST Tool Kit

X

 492697-2

 MT-RJ Jack Tool Kit

X

X

 1278346-1

X

X

 1278346-2

 Epoxy/Polish Tool Kits

X*

X

 503746-7

X*

X

 503746-1

*Note: Termination of LC Epoxy/Polish Connectors requires additional tools listed in this chapter.
**Note: Termination includes LC SECURE Connectors

Epoxy/Polish Connector Consumables/Compatibility Chart

Epoxy/Polish 
Connector

Epoxies

Polishing Films

Consumables 

Package*

EPO-TEK

TRA-CON

HYSOL

µ

m

µ

m

Diamond Film

0.3 

µ

m

Final Polishing Film

504035-1

1918652-1

502418-1

1374484-1

228433-8

503887-1

228433-5

502748-2

LC Singlemode

X

X

X

X

X

X

X

 502306-4

LC Multimode

X

X

X

X

X

X

X

 502306-4

SC Singlemode

X

X

X

X

X

X

 502306-2

SC Multimode

X

X

X

X

X

X

 502306-2

ST Singlemode

X

X

X

X

X

 502306-2

ST Multimode

X

X

X

X

 502306-1

*Note: Epoxy and fi lm for 

 100 connectors.

ORDERING INFORMATION

LightCrimp PLUS Termination Tool Kits

FEATURES

• 

Universal kits Include all tools needed for installing all

LightCrimp PLUS no-epoxy/no-polish connectors, MT-RJ, 

and MT-RJ SECURE jacks

• 

Convenient carrying case

Description

For Use With

Optional Components

Part Number

Cleave Tool 1871696-1

Inspection Microscope 1754767-1

Universal LightCrimp PLUS 
No-epoxy/No-polish Tool Kit 

LC, MT-RJ, SC, ST

X

 1278118-4

X

X

 1278118-5

LightCrimp PLUS Connector 
Termination Tool Kit

LC, SC

X

 1754845-1

X

X

 1754845-2

ST

X

 492697-1

X

X

 492697-2

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   125

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-126

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

FIBER

MT-RJ Jack Termination Tool Kit

Includes all tools needed for installing 
MT-RJ and MT-RJ SECURE jacks.

Description

Optional Components

Part Number

Cleave Tool 1871696-1

Inspection Microscope 1754767-1

MT-RJ Termination Tool Kit with cleave tool

X

1278346-1

X

X

1278346-2

Connector Type

Figure

Part Number

ST

A

492703-1

SC

B

1278023-1

LC

C

1754138-1

LC and SC

D

*2064540-1

LightCrimp Splice Holder

E

*1985771-1

* Used with die set 1985766-1

Figure A

Figure B

Figure C

Figure D

Figure E

LightCrimp PLUS Cable Holders

Used in LightCrimp PLUS connector terminations (included in LightCrimp PLUS Tool Kits).

ORDERING INFORMATION

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   126

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-127

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

FIBER

Hand Held Optical Fiber Cleaver

FEATURES

•  Cleave fi bers for LightCrimp PLUS connectors, MT-RJ, and MT-RJ SECURE jacks

• 

Operator independent

•  Blade life-span more than 10,000 cleaves

• 

Cleave surface angle <1.5°

•  No fracture, roll-off , or lip cleaves

Description

Part Number

Hand Held Optical Fiber Cleaver

1871696-1

Epoxy/Polish Connector Termination Tool Kits

FEATURES

• 

Includes all tools necessary to install the listed epoxy/polish connectors

•  For LC terminations, also order LC termination accessories kit 

• 

Tool kits include:

Description

For Use With

Part Number

LC Termination Accessories Kit (use with 503746)

LC

1754462-1

Epoxy/Polish Connector Termination Tool Kits

SC

503746-7

ST

503746-1

Pro-Crimper III Hand 

Tool and crimping dies

Polishing bushings

Polishing fi lm

Fiber strippers

Scribe tool

Includes polishing fi lms to install 60 
epoxy/polish connectors

Epoxy is sold separately 

 Does not include curing oven or microscope

Convenient carrying case

ORDERING INFORMATION

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   127

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-128

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13  313948AE

FIBER

•  For use with SC, LC and ST Connectors

• 

Pre-measured two-part packets for consistent results

• 

Can be heat-cured or cured at ambient temperature

• 

Supplied in 2-gram packets

• 

Each packet terminates 

 250 connectors

• 

25 packets per pack

• 

Pot life 

 30 minutes

• 

Cures in:

– 24 hours @ 25° C

– 2 hours @ 65° C

– 10 minutes @ 110° C

• 

Epoxy curing time starts after the oven has restabilized to the desired 
temperature after inserting the connectors into the curing block

Description

Part Number

TRA-CON Epoxy

1918652-1

TRA-CON Epoxy

FEATURES

ORDERING INFORMATION

EPO-TEK 353ND Epoxy

FEATURES

Description

Part Number

EPO-TEK 353ND Epoxy

504035-1

• 

For use with SC and LC Connectors

• 

Pre-measured two-part packets for consistent results

• 

Long pot life once mixed

• 

Heat-cured epoxy

• 

Supplied in 4-gram packets

• 

Cures in 15 minutes at 115° C

• 

Epoxy curing time starts after the oven has restabilized to the desired 
temperature after inserting the connectors into the curing block

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   128

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-129

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

FIBER

Description

Part Number

HYSOL Epoxy-Tubes

502418-1

HYSOL Epoxy-Tubes

FEATURES

•  For use with SC, LC and ST Connectors

• 

Two-part epoxy in two tubes

• 

Heat-cured epoxy

• 

Terminates

 400 connectors

• 

One set of two (2) tubes per part number

• 

Pot life

 30 minutes

• 

Cures in 30 minutes at 100° C

• 

Epoxy curing time starts after the oven has restabilized to the desired
temperature after inserting the connectors into the curing block

Epoxy Applicator Syringe

Description

Part Number

Epoxy Applicator Syringe

501473-3

ORDERING INFORMATION

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   129

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-130

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

FIBER

Epoxy Curing Oven

FEATURES

Description

Part Number

Curing Oven

110 VAC

502134-1

220 VAC

502134-2

Adapter Block for 8 Duplex Connectors

502222-1

Adapter Block for 24 Single Connectors

502129-1

LC Oven Block Assembly 

1457628-1

• 

Reduces time required to cure epoxy

•  Provides a uniform, controlled curing environment

• 

Used for all of TE's AMP NETCONNECT optical fiber epoxy/polish connectors

• 

Variable temperature control (60° C to 125° C)

• 

Includes thermometer - Epoxy curing time starts after the oven has restabilized to
the desired temperature after inserting the connectors into the curing block

• 

Includes cable support bracket

• 

Two voltage options

• 

Comes equipped to cure up to four duplex connectors and twelve simplex
connectors at once

Optional blocks reconfigure to eight duplex or twenty-four simplex connectors

ORDERING INFORMATION

Polishing Films and Consumables Kits

• 

Polishing films used to install LightCrimp and epoxy/polish connectors

• 

See listing of correct films by connector type

• 

Consumable kits include all consumables needed to install

 100 of the listed epoxy/polish connectors

Description

For Use With

Package Quantity

Grit Grade

Part Number

Hand Polishing Film

Epoxy/Polish Connectors

100

15 

µ

m

228433-9

15

µ

m

1374484-1

100

µ

m

228433-8

100

µ

m

228433-7

5

Diamond

503887-1

100

0.3 

µ

m

228433-5

Final Polishing Film

Epoxy/Polish Connectors

5

Final

502748-2

Consumables Kit

Multimode ST 

502306-1

SC, singlemode ST

502306-2

LC

502306-4

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   130

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-131

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

FIBER

Inspection Microscope

• 

Optimal visual examination of terminated ends

• 

500 

µ

m fi eld of view

• 

Dual illumination

• 

 Coaxial for inspecting polish quality 

• 

 Oblique for general conditions

•  Pre-centered, threaded adapter mount provides easy focusing and 

changing of connectors

• 

Field and laboratory examination for multimode and singlemode fi bers

• 

Portable

• 

Integral infrared fi lter for safety

  

- Do NOT use any microscope to view active fi ber signals

•  Disposable, Type LR44 batteries
•  Long-life LED (approximately 100,000 hours of operation)
• 

Each Kit includes:

 

-  10-power objective microscope with an impact resistant ergonomic 

rubber shell and high quality glass optics

  

- 20-power eyepiece

 

-  Padded carrying case with an integrated belt loop and internal adapter 

storage pocket

 

-  Neck lanyard with safety breakaway feature

 

- Universal 2.5 mm ferrule adapter (for SC, ST and FC)

Description

Part Number

Inspection Microscope

1754767-1

Connector Adapters

1.25 mm Universal

(LC and MU)

1754765-1

2.5 mm Universal

(SC, ST and FC)

1754766-1

LC Duplex

2123273-1

LC APC adapter

1553785-1

MT-RJ

1754768-1

SC APC

1828833-1

MPX

1828834-1

MPX APC

1828835-1

MPO

1828836-1

MPO APC

1828837-1

FSMA

Connector Adapter

1985040-1

Coupling adapter 

(Required for FSMA adapter)

1985041-1

DANGER: Active fi bers should never be viewed through a microscope.

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   131

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-132

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

FIBER

Polishing Bushings, Curing Sleeves, and 
Strip Card Kit

FEATURES

• 

Polishing bushings included in many tool kits

• 

Curing sleeves hold connectors in oven

Figure A

Figure C

Figure D

Figure B

Description

Cable Jacket 

Diameter (mm)

Used With

Notes

Figure

Part Number

LC Fiber Protectors,
for Buffered Fiber

Epoxy/polish LC connectors

1457630-1

LC Fiber Protectors,
for Jacketed Cable

Epoxy/polish LC connectors

1457630-2

Polish Bushing

3.0

Ceramic and stainless steel ST connectors

Metal

503337-1

Ceramic, stainless steel and polymer

composite ST connectors

Black Polymer

A

503304-1

SC connectors

Black Polymer

B

502631-1

LC connectors

Metal

1754074-1

Curing Sleeve

3.0

Ceramic, stainless steel and polymer

composite ST connectors

12 pieces

C

502259-1

SC connectors

1 piece

D

502656-1

Strip Template Kit

– 

SC and ST connectors

501818-1

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   132

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-133

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13  313948AE

FIBER

PRO-CRIMPER III Fiber Optic Hand Tool and Die Sets

FEATURES

•  Crimp tool and die sets for LightCrimp, LightCrimp PLUS, and 

Epoxy/Polish style connectors

• 

Ergonomic tool design for comfort and easy actuation

• 

Die sets are interchangeable in the crimp tool

• 

Die set 1985766-1 can be used with the fiber protective end cap in 
place for LightCrimp PLUS LC and SC connectors 

Figure A

Figure B

Description

Figure

Part Number

PRO-CRIMPER III Hand Tool  
(Die Sets Purchased Separately)

A

2064431-1

For Use With

Cable Jacket Diameter (mm)

Die Set Only

Hand Tool w/Die Set

SC (Polymer Crimp Body)

3.0

503910-1

503911-1

2.4 and 3.0

492025-1

492026-1

SC (Metal Crimp Body)

1.6 – 2.0, 2.4

1588175-1

1588176-1

3.0

492131-1

LC

1.6 – 2.0, 2.4, 3.0

1588175-1

1588176-1

ST, Ceramic 

3.0

58424-1

58433-4

ST, Stainless Steel 

3.0

58424-1

58433-4

ST, Stainless Steel (504000-X Series Only)

3.0

58552-1

58551-1

ST Ceramic Used with Loose Tube

3.8

503890-1

LightCrimp PLUS LC

1.6 - 2.0

1754136-1

1754137-1

LightCrimp PLUS and LightCrimp SC

3.0

492783-1

492782-1

LightCrimp PLUS and LightCrimp ST

3.0

492622-1

492623-1

LightCrimp PLUS LC and SC, LightCrimp Splice

2.0

B

1985766-1

2064603-1        

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   133

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-134

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

FIBER

• 

Dry cloth cleaner utilizes densely woven micro-fi ber cloth

•  Cleans male (with pins) or female MTP/MPO connectors in adapters, 

bulkheads, and faceplates

• 

Pre-washed cleaning cloth is lint and debris free

• 

Each cleaner is capable of more than 400 cleanings

• 

Protective dust cover doubles as an adapter cap for cleaning 
unmated connectors

• 

FOCIS 5-Type MTP/MPO interface compliant

• 

Removes dust and oil contamination

MTP/MPO IBC (In Bulkhead Cleaner)

FEATURES

Description

Part Number

MTP/MPO IBC (In Bulkhead Cleaner)

1918809-1

OPTIPOP R Reel Optical Connector Cleaner

• 

Densely woven micro-fi ber cloth cleans 
fi ber optic connector tips while reducing 
static charge

• 

Variety of reel cleaner confi gurations allow 
for use on the major connector types 

including FC, SC, ST, LC, MT-RJ, and MPO

Description

Figure

Part Number

MPO w/pins Reel Cleaner

A

1918802-1

One slot Reel Cleaner; 1.25mm, 2.5mm, MT no pins

B

1918803-1

MT-RJ plug w/pins Reel Cleaner

C

1918804-1

Two slot Reel Cleaner; 1.25mm and 2.5mm

D

1918805-1

Reel Cleaner refi ll (6 per pack)

E

1918806-1

Figure A

Figure B

Figure C

Figure D

Figure E

ORDERING INFORMATION

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   134

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-135

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

FIBER

OPTIPOP C Card Optical Connector Cleaner

FEATURES

• 

Densely woven micro-fi ber cloth cleans fi ber optic connector tips 
while reducing static charge

•  For use on the major connector types including FC, SC, ST, LC, 

MT-RJ, and MPO

• 

Captures debris and other contamination

• 

Cloth dimensions:
120 mm x 57 mm (4.72" x 2.24")

Description

Part Number

Fiber Connector Card Cleaner

1918810-1

Card Cleaner Refi ll (10 per pack)

1918811-1

NEOCLEAN Stick Cleaner

FEATURES

• 

Dry cloth stick cleaners utilize a densely woven micro-fi ber cloth to clean 
fi ber optic connector tips while reducing static charge

• 

Perforated handle for customizing length and angle

• 

Overall stick length: 151 mm (5.94")

• 

250 Sticks per package

Description

Part Number

Stick Cleaner - 2.5 mm Tip Diameter

1918807-1

Stick Cleaner - 1.25 mm Tip Diameter

1918808-1

ORDERING INFORMATION

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   135

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-136

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

FIBER

LC and SC Connector Cleaner (In Bulkhead Cleaner)

FEATURES

• 

Dry cloth cleaners specially designed to clean single fi ber 

connectors in adapters, bulkheads, and faceplates

• 

Dust cap of the cleaner acts as an adapter for cleaning unmated connectors

• 

Extended tip reaches recessed connectors

• 

Removes dust and oil contamination

• 

Disposable cleaner with 525+ cleanings per unit

Description

Figure

Part Number

LC Connector Cleaner (In Bulkhead Cleaner)

A

2064500-1

SC Connector Cleaner (In Bulkhead Cleaner)

B

2064499-1

Professional Fiber Connector 
Inspection/Cleaning Kits

FEATURES

•  Perform inspection, cleaning, maintenance, and troubleshooting 

on optical connectors

•  Kits include: carrying case, 200x inspection microscope,  

visual fault locator, various styles of connector cleaners, and 

detailed inspection and cleaning instructions

For Use With

Figure

Part Number

LC, SC, ST, FC, MT-RJ, and MPO Style Connectors

A

2064651-1

LC, SC, ST, FC, and MT-RJ Style Connectors

2064651-2

LC, SC, ST, and FC Style Connectors

2064651-3

Figure A

Figure A

Figure B

ORDERING INFORMATION

ORDERING INFORMATION

Sc1_Fiber_06_Accessories_v1.indd   136

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-137

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

FIBER

Velcro Cable Ties

For 8" and 12" ties, an order quantity of

one equals one roll of ten ties.

Dimensions (Approximate)

Minimum 

Tensile Strength

Maximum Bundle 

Diameter

Package 

Quantity

Color

Length

Width

Thickness

Natural

Black

4

"

 [103.0 mm]

0.096

"

 [2.44 mm]

0.037

"

 [0.94 mm]

18 lbs [80.1 N]

0.75

"

 [19.10 mm]

1000

2-604771-9

2-604771-0

100

1-604771-9

1-604771-0

6

"

 [155.0 mm]

0.140

"

 [3.56 mm]

0.045

"

 [1.14 mm]

30 lbs [133.5 N]

1.25

"

 [31.75 mm]

1000

2-603227-9

2-603227-0

100

1-603227-9

1-603227-0

8

"

 [204.0 mm]

0.184

"

 [4.67 mm]

0.047

"

 [1.19 mm]

50 lbs [222.5 N]

1.75

"

 [44.45 mm]

1000

2-604772-9

2-604772-0

100

1-604772-9

1-604772-0

12

"

 [300.0 mm]

0.183

"

 [4.65 mm]

0.051

"

 [1.30 mm]

50 lbs [222.5 N]

3.00

"

 [76.20 mm]

1000

2-604751-9

2-604751-0

100

1-604751-9

1-604751-0

AMP-TY Nylon Cable Ties

ORDERING INFORMATION

Figure A

Figure B

ORDERING INFORMATION

Part Number

Description

Figure

Black

Blue

1" x 8"

A

1375253-2

1" x 12"

B

1375254-2

5/8" x 5 yards

C

1375255-2

1375255-6

1" x 12" Flame Retardant*

1375256-2

* NOTE:  Complies with NEC 300-22(c) and (d) for use in environmental air handling spaces.  

Available in black only.

Sc1_Fiber_06_Accessories_v1.indd   137

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Accessories and Tooling

1-138

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13  313948AE

FIBER

TE offers a complete labeling solution by SharpMark for the most popular TrueNet  
copper and fiber solutions. TE labels are design to be used with a PC and standard 
laser printer. All label sheets are available through an TE authorized distribution 
partner. Contact TE Customer Service at 1-800-553-0938 for more details. 

Free Labeling Software

The free labeling software can be downloaded from TE’s website at  
www.te.com/TruenetLabeling in less than 5 minutes. 

FEATURES

• 

Easy to download software can be used with Windows or Vista

• 

Label sheets are designed specifically for TE’s most popular products

TE's TrueNet Copper and Fiber Labeling Software and Labeling Sheets

Description

UOM     Part Number 

Adhesive label for TE's TrueNet patch cords or horizontal cable 1/2" x 1 1/2' 
Each label sheet contains 105 individual labels

SH

 

ADCLS-CL4A

Adhesive label for TE's TrueNet patch cords or horizontal cable 1" x 1 1/2' 
Each label sheet contains 49 individual labels

SH

 

ADCLS-CL10A

Adhesive label for TE's TrueNet patch cords or horizontal cable 1" x 2 1/4" 
Each label sheet contains 35 individual labels

SH

 

ADCLS-CL12A

Adhesive label for TE's TrueNet patch cords or horizontal cable 1" x 5 1/2" 
Each label sheet contains 14 individual labels

SH

 

ADCLS-CL24A

Adhesive label for TE's TrueNet 192 Fiber NGF Blocks 
Each label sheet contains 1 label sheet for left side of block

SH

 

ADCLS-NGF192LCAL

Adhesive label for TE's TrueNet 192 Fiber NGF Blocks 
Each label sheet contains 1 label sheet for right side of block

SH

 

ADCLS-NGF192LCAR

Adhesive label for TE's TrueNet 144 Fiber NGF Blocks 
Each label sheet contains 1 label sheet for left side of block

SH

 

ADCLS-NGF144SCAL

Adhesive label for TE's TrueNet 144 Fiber NGF Blocks 
Each label sheet contains 1 label sheet for right side of block

SH

 

ADCLS-NGF144LCAR

Adhesive label for TE's TrueNet 1RU TFP Fiber Panel 
Each label sheet contains 16 labels for the front and back of the hinged label

SH

 

ADCLS-TFP1RUA

Adhesive label for TE's TrueNet 2RU TFP Fiber Panel 
Each label sheet contains 6 labels for the front and back of the hinged label

SH

 

ADCLS-TFP2RUA

Adhesive label for TE's TrueNet 5RU TFP Fiber Panel 
Each label sheet contains 2 labels for the front and back of the hinged label

SH

 

ADCLS-TFP5RUA

ORDERING INFORMATION

Label Sheets

designed for NGF Blocks

Sc1_Fiber_06_Accessories_v1.indd   138

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Test Equipment

1-139

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

FIBER

ORDERING INFORMATION

Description

Part Number

For use with Dual Fiber Testers with

 SC Transmit and LC Receive Ports

1828867-1

 ST Transmit and LC Receive Ports

1828867-2

 LC Transmit and LC Receive Ports

1828867-3

OM3 and OM4 (50

µ

m) and OM2 (50/125

µ

m) Multimode LC Test Kits

FEATURES

• 

Test Kits include:

– Cable assemblies

– LC duplex clips

– Mandrels

– Carrying case

• 

Test kits for LC SECURE connector systems also available

• 

See “FIELD TESTING LC OPTICAL FIBER SYSTEMS” white paper
(available on-line at www.te.com/EnterpriseNetworks) for test details

ORDERING INFORMATION

Description

Part Number

Mandrels (Transmit side only)

1435119-1

LC Duplex Clips (pack of 6)

1754371-2

SC to LC Simplex Assembly, 3 m

1907490-3

ST to LC Simplex Assembly, 3 m

1907493-3

LC to LC Simplex Assembly, 3 m

1907496-3

OM3 and OM4 (50

µ

m) and OM2 (50/125

µ

m) Multimode Replacement

Components for LC Test Kits 

FEATURES

• 

Assemblies are 3 meters in length

• 

Assemblies are simplex style

• 

Cable assemblies are riser (OFNR) rated

Sc1_Fiber_07_Test_v1.indd   139

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Test Equipment

1-140

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

FIBER

ORDERING INFORMATION

ORDERING INFORMATION

62.5/125

µ

m OM1 Multimode LC Test Kits

FEATURES

• 

Test kits include:

– Cable assemblies

– LC duplex clips

– Mandrels

– Carrying case

• 

Test kits for LC SECURE connector systems also available

• 

See “FIELD TESTING LC OPTICAL FIBER SYSTEMS” white paper
(available on-line at www.te.com/EnterpriseNetworks) for test details

62.5/125

µ

m OM1 Multimode Replacement Components for LC Test Kits

FEATURES

• 

Assemblies are 3 meters in length

• 

Assemblies are simplex style

• 

Cable assemblies are riser (OFNR) rated

Description

Part Number

For use with Dual Fiber Testers with

 SC Transmit and LC Receive Ports

1828868-1

 ST Transmit and LC Receive Ports

1828868-2

 LC Transmit and LC Receive Ports

1828868-3

Description

Part Number

Mandrels (Transmit side only)

1435118-1

LC Duplex Clips (pack of 6)

1754371-2

SC to LC Simplex Assembly, 3 m

1907491-3

ST to LC Simplex Assembly, 3 m

1907494-3

LC to LC Simplex Assembly, 3 m

1907497-3

Sc1_Fiber_07_Test_v1.indd   140

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Optic Test Equipment

1-141

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

FIBER

ORDERING INFORMATION

Singlemode LC Test Kits

FEATURES

• 

Test kits include:

– Cable assemblies

– LC duplex clips

– Mandrels

– Carrying case

• 

Test kits for LC SECURE connector systems also available

• 

See “FIELD TESTING LC OPTICAL FIBER SYSTEMS” white paper
(available on-line at www.te.com/EnterpriseNetworks) for test details

Description

Part Number

For use with Dual Fiber Testers with

 SC Transmit and LC Receive Ports

1828869-1

 ST Transmit and LC Receive Ports

1828869-2

 LC Transmit and LC Receive Ports

1828869-3

ORDERING INFORMATION

Replacement Components for Singlemode LC Test Kits

FEATURES

• 

Assemblies are 3 meters in length

• 

Assemblies are simplex style

• 

Cable assemblies are riser (OFNR) rated

Description

Part Number

LC Duplex Clips (pack of 6)

1754371-4

LC to SC Simplex Assembly, 3 m

1907489-3

LC to ST Simplex Assembly, 3 m

1907492-3

LC to LC Simplex Assembly, 3 m

1907495-3

Sc1_Fiber_07_Test_v1.indd   141

12/7/12   11:50 AM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Solutions Guide

1-142

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

19-Inch Rack

Cable Management

2 post, 3" deep

1933559-1

Horizontal 2RU panel

Single sided

1933532-1

4 post adjustable

1933570-1

Double sided

1933533-1

Double-sided 

vertical manager

6"

1933534-1

6" Combination

1933540-1

Indoor Cable

Interconnect

Distribution 

Armored 

Riser

Plenum

Riser

Plenum

Plenum

Dual

1-1553416-2

1-1553417-2

Quad

1-1553418-2

1-1553419-2

6-Fiber

1-1553307-2

1-1553308-2

2-1777121-7

12-Fiber

1-1553311-2

1-1553312-2

2-1777117-7

24-Fiber

1-1553315-2

1-1553316-2

1-1553420-2

Indoor/Outdoor Cable

Outdoor Cable

Riser

Plenum

OSP

OSPA

6-Fiber

6-1553342-2

6-1553343-2

6-1553387-2

6-1553397-2

12-Fiber

6-1553346-2

6-1553347-2

6-1553389-2

6-1553399-2

24-Fiber

6-1553348-2

6-1553349-2

6-1553390-2

6-1553400-2

Patch Panels

TFP

1RU

TFP-1TT00-000B

RMG

1RU

RMG-1000-000B

2RU

TFP-2TT00-000B

2RU

RMG-2000-000B

5RU

TFP-5TT00-000B

4RU

RMG-4000-000B

TFP Adapters

6 SC Duplex

TFP-12APLC3 and 

TFP-12APRC3

RMG Adapters

6 SC Duplex

RMG-12ADPC3

12 LC Duplex

TFP-24APLQ1 and 

TFP-24APRQ1

12 LC Duplex

RMG-24ADPQ3

Patch Cords

1 m

2 m

3 m

5 m

SC/SC Duplex

PAT-SCSC-R20C001M

PAT-SCSC-R20C002M

PAT-SCSC-R20C003M

PAT-SCSC-R20C005M

SC/LC Duplex

PAT-LCSC-R20C001M

PAT-LCSC-R20C002M

PAT-LCSC-R20C003M

PAT-LCSC-R20C005M

LC/LC Duplex

PAT-LCLC-R20C001M

PAT-LCLC-R20C002M

PAT-LCLC-R20C003M

PAT-LCLC-R20C005M

Fiber Optic OM2 Solution

4

2

3

5

1

1

2

3

3

3

4

5

Sc1_Fiber_07_Test_v1.indd  142

12/11/12  5:28 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Solutions Guide

1-143

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

19-Inch Rack

Cable Management

2 post, 3" deep

1933559-1

Horizontal 2RU panel

Single sided

1933532-1

4 post adjustable

1933570-1

Double sided

1933533-1

Double-sided 

vertical manager

6"

1933534-1

6" Combination

1933540-1

Indoor Cable

Interconnect

Distribution 

Armored 

Riser

Plenum

Riser

Plenum

Plenum

Dual

3-1553416-9

3-1553417-9

Quad

3-1553418-9

3-1553419-9

6-Fiber

3-1553307-9

3-1553308-9

3-1777121-7

12-Fiber

3-1553311-9

3-1553312-9

3-1777117-7

24-Fiber

3-1553315-9

3-1553316-9

3-1553420-9

Indoor/Outdoor Cable

Outdoor Cable

Riser

Plenum

OSP

OSPA

6-Fiber

6-1553342-4

6-1553343-4

6-1553387-4

6-1553397-4

12-Fiber

6-1553346-4

6-1553347-4

6-1553389-4

6-1553399-4

24-Fiber

6-1553348-4

6-1553349-4

6-1553390-4

6-1553400-4

Patch Panels

TFP

1RU

TFP-1TT00-000B

RMG

1RU

RMG-1000-000B

2RU

TFP-2TT00-000B

2RU

RMG-2000-000B

5RU

TFP-5TT00-000B

4RU

RMG-4000-000B

TFP Adapters

6 SC Duplex

TFP-12APLC4 and 

TFP-12APRC4

RMG Adapters

6 SC Duplex

RMG-12ADPC4

12 LC Duplex

TFP-24APLQ2 and 

TFP-24APRQ2

12 LC Duplex

RMG-24ADPQ4

Patch Cords

1 m

2 m

3 m

5 m

SC/SC Duplex

PAT-SCSC-R30C001M

PAT-SCSC-R30C002M

PAT-SCSC-R30C003M

PAT-SCSC-R30C005M

SC/LC Duplex

PAT-LCSC-R30C001M

PAT-LCSC-R30C002M

PAT-LCSC-R30C003M

PAT-LCSC-R30C005M

LC/LC Duplex

PAT-LCLC-R30C001M

PAT-LCLC-R30C002M

PAT-LCLC-R30C003M

PAT-LCLC-R30C005M

Fiber Optic OM3 Solution

2

3

3

3

4

5

1

4

2

3

5

1

Sc1_Fiber_07_Test_v1.indd  143

12/11/12  5:28 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Solutions Guide

1-144

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

19-Inch Rack

Cable Management

2 post, 3" deep

1933559-1

Horizontal 2RU panel

Single sided

1933532-1

4 post adjustable

1933570-1

Double sided

1933533-1

Double-sided 

vertical manager

6"

1933534-1

6" Combination

1933540-1

Indoor Cable

Interconnect

Distribution 

Armored 

Riser

Plenum

Riser

Plenum

Plenum

Dual

4-1553416-9

4-1553417-9

Quad

3-1553418-9

4-1553419-9

6-Fiber

4-1553307-9

4-1553308-9

7-1777121-7

12-Fiber

4-1553311-9

4-1553312-9

7-1777117-7

24-Fiber

4-1553315-9

4-1553316-9

4-1553420-9

Indoor/Outdoor Cable

Outdoor Cable

Riser

Plenum

OSP

OSPA

6-Fiber

6-1553342-5

6-1553343-5

6-1553387-5

6-1553397-5

12-Fiber

6-1553346-5

6-1553347-5

6-1553389-5

6-1553399-5

24-Fiber

6-1553348-5

6-1553349-5

6-1553390-5

6-1553400-5

Patch Panels

TFP

1RU

TFP-1TT00-000B

RMG

1RU

RMG-1000-000B

2RU

TFP-2TT00-000B

2RU

RMG-2000-000B

5RU

TFP-5TT00-000B

4RU

RMG-4000-000B

TFP Adapters

6 SC Duplex

TFP-12APLC4 and 

TFP-12APRC4

RMG Adapters

6 SC Duplex

RMG-12ADPC4

12 LC Duplex

TFP-24APLQ2 and 

TFP-24APRQ2

12 LC Duplex

RMG-24ADPQ4

Patch Cords

1 m

2 m

3 m

5 m

SC/LC Duplex

PAT-LCSC-RS0C001M

PAT-LCSC-RS0C002M

PAT-LCSC-RS0C003M

PAT-LCSC-RS0C005M

LC/LC Duplex

PAT-LCLC-RS0C001M

PAT-LCLC-RS0C001M

PAT-LCLC-RS0C001M

PAT-LCLC-RS0C001M

Fiber Optic OM4 Solution

1

2

3

3

3

4

5

4

2

3

5

1

Sc1_Fiber_07_Test_v1.indd  144

12/11/12  5:28 PM

Tyco-catalog-AMP-2013-html.html
background image

Fiber

Fiber Solutions Guide

1-145

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

FIBER

19-Inch Rack

Cable Management

2 post, 3" deep

1933559-1

Horizontal 2RU panel

Single-sided

1933532-1

4 post adjustable

1933570-1

Double-sided

1933533-1

Double-sided 

vertical manager

6"

1933534-1

6" Combination

1933540-1

Indoor Cable

Interconnect

Distribution 

Armored 

Riser

Plenum

Riser

Plenum

Plenum

Dual

7-1553416-3

7-1553417-3

Quad

7-1553418-3

7-1553419-3

6-Fiber

7-1553307-3

7-1553308-3

4-1777121-7

12-Fiber

7-1553311-3

7-1553312-3

4-1777117-7

24-Fiber

7-1553315-3

7-1553316-3

4-1553420-7

Indoor/Outdoor Cable

Outdoor Cable

Riser

Plenum

OSP

OSPA

6-Fiber

6-1553342-3

6-1553343-3

6-1553387-3

6-1553397-3

12-Fiber

6-1553346-3

6-1553347-3

6-1553389-3

6-1553399-3

24-Fiber

6-1553348-3

6-1553349-3

6-1553390-3

6-1553400-3

Patch Panels

TFP

1RU

TFP-1TT00-000B

RMG

1RU

RMG-1000-000B

2RU

TFP-2TT00-000B

2RU

RMG-2000-000B

5RU

TFP-5TT00-000B

4RU

RMG-4000-000B

TFP Adapters

6 SC Duplex

TFP-12APLC8 and 

TFP-12APRC8

RMG Adapters

6 SC Duplex

RMG-12ADPC8

12 LC Duplex

TFP-24APLQ5 and 

TFP-24APRQ5

12 LC Duplex

RMG-24ADPQ8

Patch Cords

1 m

2 m

3 m

5 m

SC/LC Duplex

PAT-LCSC-RS0C001M

PAT-LCSC-RS0C002M

PAT-LCSC-RS0C003M

PAT-LCSC-RS0C005M

LC/LC Duplex

PAT-LCLC-RS0C001M

PAT-LCLC-RS0C001M

PAT-LCLC-RS0C001M

PAT-LCLC-RS0C001M

Fiber Optic Singlemode Solution

2

3

3

3

4

5

1

4

2

3

5

1

Sc1_Fiber_07_Test_v1.indd  145

12/11/12  5:28 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Products

2-1

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

SECURE Network Solutions – Fiber Products .....................2-3

SECURE Network Solutions – Copper Products ................2-17

TE is a proven provider of reliable network infrastructure for the 
most mission-critical networks. We understand the serious nature 
of a network installation and its security issues. TE offers a variety 
of options with our SECURE products including color-coded, 
keyed technologies and more. Available for both our copper and 
fiber cabling solutions, we can meet your requirements for secure 
applications and compliance to global regulations.  

Sc2_SECURENetworkSolutions_v1.indd   1

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-3

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

SECURE Fiber Connectivity

The solution to managing multiple networks with reduced risks of improper
cross-connection, inadvertent physical access, and of malicious access.

FEATURES

• 

Keyed connectors, adapters and cable assemblies prevent improper
connection of separate networks with common access points

• 

Color codes make proper connection easier

• 

Standard connector versions will not mate with SECURE systems

• 

SECURE Cassettes are installed into RMG chassis

LC SECURE LightCrimp PLUS Simplex Connectors (No expoxy/No polish)

FEATURES

• 

Ten color-coded keyed designs limit improper connections in segregated networks

• 

LC SECURE connectors only mate with LC SECURE adapters of the same color

• 

LC SECURE LightCrimp PLUS connectors feature ceramic ferrules

• 

Select appropriate part number for termination to:

900

µ

m tight-buff ered or 250

µ

m coated fi bers

1.6 – 2.0 mm jacketed fi ber

• 

Easy installation:

No epoxy, no polishing

No bench tool required

Strip, cleave, and crimp

• 

LC SECURE LightCrimp PLUS connector uses the same installation tooling as the
standard LC LightCrimp PLUS connector

• 

LC Duplex clip (black, sold separately) links two simplex LC connectors to make one
duplex LC connector and allows for polarity correction after termination

900

 

µ

m

Tight-buff

 er

ed

250

 

µ

C

oa

ted

1.6

 –

 2

.0

 mm

Jack

et

ed

Fiber 
Type

Boot 

Color

Part Number

Red

Yellow

Green

Blue

Rose

Aqua

Brown

Violet

Orange

Slate

50 

µ

m OM2

Black

×

×

×

1985959-1

1985959-2

1985959-3

1985959-4

1985959-5

1985959-6

1985959-7

1985959-8

1985959-9

1-1985959-0

XG OM3/
OM4 50 

µ

m

Aqua

×

×

×

1985960-1

1985960-2

1985960-3

1985960-4

1985960-5

1985960-6

1985960-7

1985960-8

1985960-9

1-1985960-0

62.5 

µ

m OM1

Beige

×

×

×

1985961-1

1985961-2

1985961-3

1985961-4

1985961-5

1985961-6

1985961-7

1985961-8

1985961-9

1-1985961-0

Singlemode

Blue

×

×

1828856-1

1828856-2

1828856-3

1828856-4

1828856-5

1828856-6

1828856-7

1828856-8

1828856-9

1-1828856-0

×

1828860-1

1828860-2

1828860-3

1828860-4

1828860-5

1828860-6

1828860-7

1828860-8

1828860-9

1-1828860-0

Note: Table colors are for reference only.

ORDERING INFORMATION

Red

Green

Rose

Brown

Orange

Yellow

Blue

Aqua

Violet

Slate

Sc2_SECURENetworkSolutions_v1.indd   3

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-4

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

ORDERING INFORMATION

LC Duplex Clips

Description

Package Quantity Part Number

LC Duplex Clips

6

1754371-2

FEATURES

• 

Used to link two simplex LC connectors to make one duplex LC connector

• 

Compatible with singlemode or multimode simplex connectors

• 

Available colors: black

• 

Available in packages of six (6)

Part Number

Fiber Type

For Use with

Red

Yellow

Green

Blue

Rose

Aqua

Brown

Violet

Orange

Slate

Multimode

1.6 – 2.0 mm 

Jacketed Fiber

1828078-1

1828078-2

1828078-3

1828078-4

1828078-5

1828078-6

1828078-7

1828078-8

1828078-9

1-1828078-0

900 

µ

m Tight-

buff ered or 250 

µ

m Coated Fibers

1828861-1

1828861-2

1828861-3

1828861-4

1828861-5

1828861-6

1828861-7

1828861-8

1828861-9

1-1828861-0

Singlemode

1.6 – 2.0 mm 

Jacketed Fiber

1828079-1

1828079-2

1828079-3

1828079-4

1828079-5

1828079-6

1828079-7

1828079-8

1828079-9

1-1828079-0

900 

µ

m Tight-buff ered 

or 250 

µ

m Coated Fibers

1828862-1

1828862-2

1828862-3

1828862-4

1828862-5

1828862-6

1828862-7

1828862-8

1828862-9

1-1828862-0

Note: Table colors are for reference only.

ORDERING INFORMATION

LC SECURE Epoxy/Polish Simplex Connectors

FEATURES

• 

Ten color-coded keyed designs limit improper connections in segregated networks

• 

LC SECURE connectors only mate with LC SECURE adapters of the same color

• 

Duplex clip (black, sold separately) attaches two simplex connectors into duplex
form and allows for polarity correction after termination

• 

Two LC SECURE connector kits for each fi ber type (multimode and singlemode)

• 

One terminates either one 250

µ

m coated fi ber or one 900

µ

m tight-buff ered fi ber

• 

One terminates one 1.6 mm to 2.0 mm jacketed fi ber

• 

Multimode connectors are suitable for use with 50/125

µ

m,

XG OM3/OM4 50/125

µ

m, and 62.5/125

µ

m fi bers and come with beige boots

• 

Singlemode connectors are suitable for use with all singlemode fi ber types and
come with blue boots

• 

LC SECURE connectors uses the same LC installation tooling as standard LC

• 

Suitable for use with heat-cured or anaerobic (quick cure) adhesives

Red

Green

Rose

Brown

Orange

Yellow

Blue

Aqua

Violet

Slate

Sc2_SECURENetworkSolutions_v1.indd   4

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-5

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

LC Duplex Clips

Part Number

Fiber Type

For Use with

Red

Yellow

Green

Blue

Rose

Aqua

Brown

Violet

Orange

Slate

Multimode

1.6 – 2.0 mm 

Jacketed Fiber

1828078-1

1828078-2

1828078-3

1828078-4

1828078-5

1828078-6

1828078-7

1828078-8

1828078-9

1-1828078-0

900 

µ

m Tight-

buff ered or 250 

µ

m Coated Fibers

1828861-1

1828861-2

1828861-3

1828861-4

1828861-5

1828861-6

1828861-7

1828861-8

1828861-9

1-1828861-0

Singlemode

1.6 – 2.0 mm 

Jacketed Fiber

1828079-1

1828079-2

1828079-3

1828079-4

1828079-5

1828079-6

1828079-7

1828079-8

1828079-9

1-1828079-0

900 

µ

m Tight-buff ered 

or 250 

µ

m Coated Fibers

1828862-1

1828862-2

1828862-3

1828862-4

1828862-5

1828862-6

1828862-7

1828862-8

1828862-9

1-1828862-0

Note: Table colors are for reference only.

LC SECURE SL Series Duplex Couplers

FEATURES

• 

Ten color-coded keyed designs limit improper connections in segregated networks

• 

LC SECURE connectors only mate with LC SECURE couplers of the same color

• 

Hybrid Coupler – mates LC SECURE connectors to standard connectors

• 

LC SECURE coupler on the work area side

• 

Couplers suitable for use with multimode and singlemode LC SECURE connectors

• 

Easily snaps into SL series modules, duplex mounting straps, patch panels,
and enclosures

• 

May be used in straight or angled faceplate modules

• 

Confi gure faceplates with one or more LC SECURE connectors to provide a
common access point to multiple segregated or secured networks

Part Number

Description

Fiber Type

Red

Yellow

Green

Blue

Rose

Aqua

Brown

Violet

Orange

Slate

LC SECURE 
Coupler

Multimode and 

Singlemode

1933422-1

1933422-2

1933422-3

1933422-4

1933422-5

1933422-6

1933422-7

1933422-8

1933422-9

1-1933422-0

LC SECURE 
Hybrid Coupler

Multimode and 

Singlemode

1933285-1

1933285-2

1933285-3

1933285-4

1933285-5

1933285-6

1933285-7

1933285-8

1933285-9

1-1933285-0

Note: Table colors are for reference only.

ORDERING INFORMATION

Sc2_SECURENetworkSolutions_v1.indd   5

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-6

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

SECURE Adapter Plate

without Shutters

SECURE Adapter Plate 

with Blue Shutters

LC SECURE Snap-In Adapter Plates

FEATURES

• 

Ten color-coded keyed designs limit improper connections in segregated networks

• 

LC SECURE connectors only mate with LC SECURE adapters of the same color

• 

Package quantity: 1 plate per pack

• 

Adapters suitable for use with multimode or singlemode LC SECURE connectors

• 

Snap-in adapter plates fit in unloaded optical fiber enclosures 

• 

Snap-in adapter plates are pre-loaded with either six (6) or 
twelve (12) duplex LC SECURE adapters

• 

Adapter plates with shutters contain a spring loaded cover to protect connectors 
from fine particulates

• 

SECURE snap-in adapter plates fit RMG unloaded optical fiber enclosures

ORDERING INFORMATION

Fiber 
Type

Fiber 

Count

Duplex

Port 

Count

Shutters

Part Number

Red

Yellow

Green

Blue

Rose

Aqua

Brown

Violet

Orange

Slate

Multi
mode 
or 
Single 
mode

12

6

Without

1777127-1

1777127-2

1777127-3

1777127-4

1777127-9

1-1777127-0

1777127-6

1777127-8

1777127-5

1777127-7

With Blue

1777265-1

1777265-2

1777265-3

1777265-4

1777265-9

1-1777265-0

1777265-6

1777265-8

1777265-5

1777265-7

With Aqua

1777266-1

1777266-2

1777266-3

1777266-4

1777266-9

1-1777266-0

1777266-6

1777266-8

1777266-5

1777266-7

24

12

Without

1499702-2

1499703-2

1499704-2

1499705-2

1499706-2

1499707-2

1499708-2

1499709-2

1499710-2

1499711-2

Note: Table colors are for reference only.

Sc2_SECURENetworkSolutions_v1.indd   6

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-7

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

Fiber 
Type

Fiber 

Count

Duplex

Port 

Count

Shutters

Part Number

Red

Yellow

Green

Blue

Rose

Aqua

Brown

Violet

Orange

Slate

Multi
mode 
or 
Single 
mode

12

6

Without

1777127-1

1777127-2

1777127-3

1777127-4

1777127-9

1-1777127-0

1777127-6

1777127-8

1777127-5

1777127-7

With Blue

1777265-1

1777265-2

1777265-3

1777265-4

1777265-9

1-1777265-0

1777265-6

1777265-8

1777265-5

1777265-7

With Aqua

1777266-1

1777266-2

1777266-3

1777266-4

1777266-9

1-1777266-0

1777266-6

1777266-8

1777266-5

1777266-7

24

12

Without

1499702-2

1499703-2

1499704-2

1499705-2

1499706-2

1499707-2

1499708-2

1499709-2

1499710-2

1499711-2

Note: Table colors are for reference only.

MPO SECURE to Non-SECURE LC Optical Fiber Cassettes

FEATURES

• 

Ten color-coded keyed designs limit improper connections in segregated networks

• 

Cassettes have one MPO connection (12-fiber) or two MPO connections
(24-fiber) on the back

• 

Cassettes house one or two 12-fiber break-out assemblies

• 

Cassette fiber polarity is pair-flipped (AB/BA)

• 

Cassettes with pair-straight polarity (AB/AB) are available - call for details

• 

Cassettes have same footprint as the snap-in adapter plates and fit in unloaded RMG
optical fiber enclosures

• 

Factory tested and ready for installation

• 

For use with standard (non-secure) MPO trunk assemblies

ORDERING INFORMATION

Fiber 
Type

Fiber 

Count

Duplex 

Port 

Count

Part Number

Red

Yellow

Green

Blue

Rose

Aqua

Brown

Violet

Orange

Slate

62.5 

µ

OM1

12

6

1985799-2

1985799-5

1985799-3

1985799-4

1985799-9

1-1985799-1

1985799-7

1985799-8

1985799-6

1-1985799-0

24

12

1938967-2

1938967-5

1938967-3

1938967-4

1938967-9

1-1938967-1

1938967-7

1938967-8

1938967-6

1-1938967-0

50 

µ

OM2

12

6

1985798-2

1985798-5

1985798-3

1985798-4

1985798-9

1-1985798-1

1985798-7

1985798-8

1985798-6

1-1985798-0

24

12

1938966-2

1938966-5

1938966-3

1938966-4

1938966-9

1-1938966-1

1938966-7

1938966-8

1938966-6

1-1938966-0

XG OM3 
50 

µ

m

12

6

1985713-2

1985713-5

1985713-3

1985713-4

1985713-9

1-1985713-1

1985713-7

1985713-8

1985713-6

1-1985713-0

24

12

1918785-2

1918785-5

1918785-3

1918785-4

1918785-9

1-1918785-1

1918785-7

1918785-8

1918785-6

1-1918785-0

Single 
mode

12

6

1985797-2

1985797-5

1985797-3

1985797-4

1985797-9

1-1985797-1

1985797-7

1985797-8

1985797-6

1-1985797-0

24

12

1918786-2

1918786-5

1918786-3

1918786-4

1918786-9

1-1918786-1

1918786-7

1918786-8

1918786-6

1-1918786-0

Note: Table colors are for reference only.

Sc2_SECURENetworkSolutions_v1.indd   7

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-8

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

LC SECURE Duplex Hybrid Cable Assemblies

FEATURES

• 

Assemblies have SECURE connector on one end and a standard connector on the
other end for connecting to equipment

• 

Other constructions and combinations are available - call for details

• 

Ten color-coded keyed designs limit improper connections in segregated networks

• 

LC SECURE plugs only mate with LC SECURE adapters of the same color

• 

LC SECURE connectors feature ceramic ferrules

• 

Standard jacket color is yellow for singlemode, orange for 50/125

µ

m and

62.5/125

µ

m, and aqua for OM3 and OM4

• 

Cable assemblies are riser-rated  (Other ratings are available - call for details)

Duplex LC SECURE

Duplex LC

MT-RJ

ORDERING INFORMATION

Description

Part Number

OM1 Duplex LC SECURE to Duplex LC

PAT-LC8z-R10CxxxM

OM1 Duplex LC SECURE to MT-RJ

PAT-MC8z-R10BxxxM

OM2 Duplex LC SECURE to Duplex LC

PAT-LC8z-R20CxxxM

OM2 Duplex LC SECURE to MT-RJ

PAT-MC8z-R20BxxxM

OM3 Duplex LC SECURE to Duplex LC

PAT-LC8z-R30CxxxM

OM3 Duplex LC SECURE to MT-RJ

PAT-MC8z-R30BxxxM

OM4 Duplex LC SECURE to Duplex LC

PAT-LC8z-R40CxxxM

OM4 Duplex LC SECURE to MT-RJ

PAT-MC8z-R40BxxM

Note: z = color:  B = Blue, N = Orange, G = Green, W = Brown, 
S = Slate, R = Red, Y = Yellow, V = Violet, P = Rose, A = Aqua, 
xxx = length in feet or meters: M = Meters
Refer to Cable Assembly spec 402-1007 for complete ordering information

Sc2_SECURENetworkSolutions_v1.indd   8

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-9

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

LC SECURE Duplex Hybrid Cable Assemblies

ORDERING INFORMATION

Part Number

PAT- __ __ __ __ – __ __ __ __ __ __ __ __ __

Connector A Color/Keying

C

Standard

B

Secure Blue

N

Secure Orange

G

Secure Green

W

Secure Brown

S

Secure Slate

R

Secure Red

Y

Secure Yellow

V

Secure Violet

P

Secure Rose

A

Secure Aqua

Connector B Color/Keying

C

None/Pigtails

0

None

B

Secure Blue

N

Secure Orange

G

Secure Green

W

Secure Brown

S

Secure Slate

R

Secure Red

Y

Secure Yellow

V

Secure Violet

P

Secure Rose

A

Secure Aqua

U

Universal

Cable Jacket Color

0

Standard

B

Blue

N

Orange

G

Green

W

Brown

S

Slate

R

Red

Y

Yellow

V

Violet

P

Rose

A

Aqua

Cable Jacket Material

P

Plenum

R

Riser

0

900 

µ

Fiber Type

1

OM1

2

OM2

3

OM3

4

OM4

5

OS2

Cable Type

A

1.6mm Zipcord

B

1.8mm Zipcord

C

2.0mm Zipcord

D

3.0mm Zipcoard

E

900

µ

F

2.0mm Simplex

Assembly Length

001

Shortest possible length

999

Longest possible length

Unit of Measure

F

Feet

M

Meters

Polarity

BLANK

Standard A to B Duplex

S

Straight A to A

Connector A Type

L

LC

S

SC

T

ST

F

FC

M

MTRJ w/o pins

W

MTRJ w/pins

3

LC Optimate Duplex

4

SC Optimate Duplex

5

FC APC

6

SC APC

7

LC APC

8

LC Secure Duplex

9

MT-RJ Secure Plug

Connector B Type

0

None

C

None/Pigtails

L

LC

S

SC

T

ST

F

FC

M

MTRJ w/o pins

W

MTRJ w/pins

3

LC Optimate Duplex

4

SC Optimate Duplex

5

FC APC

6

SC APC

7

LC APC

8

LC Secure Duplex

9

MT-RJ Secure Plug

Sc2_SECURENetworkSolutions_v1.indd   9

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-10

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

LC SECURE Duplex Hybrid Cable Assemblies

Duplex LC SECURE

Duplex SC

ORDERING INFORMATION

Description

Part Number

OM1 Duplex LC SECURE to Duplex SC

PAT-SC8z-R10CxxxM

OM1 Duplex LC SECURE to Dual ST

PAT-TC8z-R10BxxxM

OM2 Duplex LC SECURE to Duplex SC

PAT-SC8z-R20CxxxM

OM2 Duplex LC SECURE to Dual ST

PAT-TC8z-R20BxxxM

OM3 Duplex LC SECURE to Duplex SC

PAT-SC8z-R30CxxxM

OM3 Duplex LC SECURE to Dual ST

PAT-TC8z-R30BxxxM

OM4 Duplex LC SECURE to Duplex SC

PAT-SC8z-R40CxxxM

OM4 Duplex LC SECURE to Dual ST

PAT-TC8z-R40BxxxM

Note: z = color:  B = Blue, N = Orange, G = Green, W = Brown, 
S = Slate, R = Red, Y = Yellow, V = Violet, P = Rose, A = Aqua, 
xxx = length in feet or meters: M = Meters 
Refer to Cable Assembly spec 402-1007 for complete ordering information

Dual ST

Sc2_SECURENetworkSolutions_v1.indd   10

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-11

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

ORDERING INFORMATION

Description

Part Number

OM1 Duplex MTRJ SECURE to MTRJ

PAT-MC9z-R10BxxxM

OM1 Duplex MTRJ SECURE to LC Duplex

PAT-LC9z-R10BxxxM

OM1 Duplex MTRJ SECURE to SC Duplex

PAT-SC9z-R10BxxxM

OM1 Duplex MTRJ SECURE to Dual ST

PAT-TC9z-R10BxxxM

OM2 Duplex MTRJ SECURE to MTRJ

PAT-MC9z-R20BxxxM

OM2 Duplex MTRJ SECURE to LC Duplex

PAT-LC9z-R20BxxxM

OM2 Duplex MTRJ SECURE to SC Duplex

PAT-SC9z-R20BxxxM

OM2 Duplex MTRJ SECURE to Dual ST

PAT-TC9z-R20BxxxM

OM3 Duplex MTRJ SECURE to MTRJ

PAT-MC9z-R30BxxxM

OM3 Duplex MTRJ SECURE to LC Duplex

PAT-LC9z-R30BxxxM

OM3 Duplex MTRJ SECURE to SC Dupex

PAT-SC9z-R30BxxxM

OM3 Duplex MTRJ SECURE to Dual ST

PAT-TC8z-R30BxxxM

OM4 Duplex MTRJ SECURE to Duplex SC

PAT-LC9z-R40BxxxM

OM4 Duplex MTRJ SECURE to Dual ST

PAT-MC9z-R40BxxxM

Note: z = color:  B = Blue, N = Orange, G = Green, W = Brown, 
S = Slate, R = Red, Y = Yellow, V = Violet, P = Rose, A = Aqua, 
xxx = length in feet or meters: M = Meters
Refer to Cable Assembly spec 402-1007 for complete ordering information

FEATURES

• 

Assemblies have SECURE connector on one end and a standard connector on
the other end for connecting to equipment

• 

Other constructions and combinations are available - call for details

• 

Ten color-coded keyed designs limit improper connections in
segregated networks

• 

MT-RJ plugs only mate with similar type SECURE jacks of the same color

• 

Each MT-RJ and MT-RJ SECURE connector houses two fi bers

• 

Standard jacket color is yellow for singlemode, orange for 50/125

µ

m and

62.5/125

µ

m, and aqua for XG OM3 50/125

µ

m

• 

Cable assemblies are riser-rated  (Other ratings are available - call for details)

MT-RJ SECURE Hybrid Cable Assemblies

Sc2_SECURENetworkSolutions_v1.indd   11

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-12

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

MT-RJ SECURE Outlet Jacks 

Easy 3 Step Termination

Strip

Cleave

Lock

FEATURES

• 

Ten color-coded keyed designs limit improper connections in segregated networks

• 

MT-RJ SECURE plugs only mate with MT-RJ SECURE jacks of the same color

• 

Match cable fiber type to jack fiber type for correct part number

• 

MT-RJ optical fiber jacks terminate two fibers per jack

• 

Jack design eliminates need for MT-RJ SECURE adapter

• 

Small form factor design is half the size of SC duplex

• 

No epoxy, no polishing, no crimping

• 

Can be re-terminated - improves yield

• 

Each fiber is tunable and locked separately

• 

No bench tool required

• 

Shares the same installation tools and procedures as standard MT-RJ jacks

• 

MT-RJ SECURE outlet jacks are for use with 900 

µ

m tight-buffered fibers

• 

Each MT-RJ SECURE outlet jack part number includes:

One (1) MT-RJ SECURE outlet jack

Actuation tool

SL Series housing in matching color

Bend-limiting boot (black)

• 

MT-RJ SECURE patch panel jacks are for use with 900 um tight-buffered fibers 
or 250 um coated fibers (select appropriate part number)

• 

MT-RJ SECURE patch panel jack part number includes:

Six (6) MT-RJ SECURE patch panel jacks

Two (2) actuation tools

Fiber guide

Icon wheel

• 

Six patch panel jacks fit in one MT-RJ Snap-in Adapter Plate (sold separately)

• 

SL series housings and bend-limiting boots sold separately

• 

MT-RJ SECURE cable assemblies listed in this chapter

• 

Singlemode MT-RJ SECURE jacks are available as pigtail assemblies. Call for details

Sc2_SECURENetworkSolutions_v1.indd   12

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-13

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

MT-RJ SECURE Outlet Jacks

ORDERING INFORMATION

Part Number

62.5 

µ

m OM1

50 

µ

m OM2

XG OM3 50 

µ

m

Jack Type

SECURE 

Jack Color

Figure

900 

µ

m Tight-

buffered Fibers

250 

µ

Coated Fiber  

900 

µ

m Tight-

buffered Fibers

250 

µ

Coated Fiber  

900 

µ

m Tight-

buffered Fibers

250 

µ

Coated Fiber  

Outlet

Red

A

6278810-1

6278811-1

6754252-1

Yellow

B

6278810-2

6278811-2

6754252-2

Green

C

6278810-3

6278811-3

6754252-3

Blue

D

6278810-4

6278811-4

6754252-4

Rose

E

6278810-5

6278811-5

6754252-5

Aqua

F

6278810-6

6278811-6

6754252-6

Brown

G

6278810-7

6278811-7

6754252-7

Violet

H

6278810-8

6278811-8

6754252-8

Orange

I

6278810-9

6278811-9

6754252-9

Slate

J

1-6278810-0

1-6278811-0

1-6754252-0

Patch 
Panel

Red

K

6588878-1

6278808-1

6588879-1

6278807-1

6693949-1

6693951-1

Yellow

6588878-2

6278808-2

6588879-2

6278807-2

6693949-2

6693951-2

Green

6588878-3

6278808-3

6588879-3

6278807-3

6693949-3

6693951-3

Blue

6588878-4

6278808-4

6588879-4

6278807-4

6693949-4

6693951-4

Rose

6588878-5

6278808-5

6588879-5

6278807-5

6693949-5

6693951-5

Aqua

6588878-6

6278808-6

6588879-6

6278807-6

6693949-6

6693951-6

Brown

6588878-7

6278808-7

6588879-7

6278807-7

6693949-7

6693951-7

Violet

6588878-8

6278808-8

6588879-8

6278807-8

6693949-8

6693951-8

Orange

6588878-9

6278808-9

6588879-9

6278807-9

6693949-9

6693951-9

Slate

1-6588878-0

1-6278808-0

1-6588879-0

1-6278807-0

1-6693949-0

1-6693951-0

Note: Table colors are for reference only.

B

I

C

F

D

H

J

G

E

A

Figure K

Sc2_SECURENetworkSolutions_v1.indd   13

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-14

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

FEATURES

• 

Ten color-coded keyed designs limit improper connections in segregated networks

• 

MPO SECURE plugs only mate with MPO SECURE adapters of the same color

• 

Cassettes have one MPO SECURE connection (12-Fiber) or two MPO SECURE
connections (24-Fiber) on the back

• 

Cassettes house one or two 12-fiber break-out assemblies

• 

MPO SECURE cassette color matches the LC SECURE or MT-RJ SECURE adapter
color of the cassette

• 

Cassette fiber polarity is pair-flipped (AB/BA)

• 

Cassettes with pair-straight polarity (AB/AB) are available - call for details

• 

Cassettes have same footprint as the snap-in adapter plates and fit in unloaded
RMG optical fiber enclosures

• 

Factory tested and ready for installation

MPO SECURE Optical Fiber Cassettes

ORDERING INFORMATION

Part Number

SECURE 
Color

Fiber 

Count

Duplex 

Port 

Count

MT-RJ SECURE

LC SECURE

62.5 

µ

OM1

50 

µ

m OM2

XG OM3 

50 

µ

m

Singlemode

62.5 

µ

OM1

50 

µ

m OM2

XG OM3 

50 

µ

m

Singlemode

Red

12

6

6754285-2

6754286-2

1918777-2

1938996-2

1918781-2

1918779-2

1918783-2

1938056-2

24

12

6754287-2

6754288-2

1918778-2

6828819-2

1918782-2

1918780-2

1918784-2

1938965-2

Green

12

6

6754285-3

6754286-3

1918777-3

1938996-3

1918781-3

1918779-3

1918783-3

1938056-3

24

12

6754287-3

6754288-3

1918778-3

6828819-3

1918782-3

1918780-3

1918784-3

1938965-3

Blue

12

6

6754285-4

6754286-4

1918777-4

1938996-4

1918781-4

1918779-4

1918783-4

1938056-4

24

12

6754287-4

6754288-4

1918778-4

6828819-4

1918782-4

1918780-4

1918784-4

1938965-4

Yellow

12

6

6754285-5

6754286-5

1918777-5

1938996-5

1918781-5

1918779-5

1918783-5

1938056-5

24

12

6754287-5

6754288-5

1918778-5

6828819-5

1918782-5

1918780-5

1918784-5

1938965-5

Orange

12

6

6754285-6

6754286-6

1918777-6

1938996-6

1918781-6

1918779-6

1918783-6

1938056-6

24

12

6754287-6

6754288-6

1918778-6

6828819-6

1918782-6

1918780-6

1918784-6

1938965-6

Brown

12

6

6754285-7

6754286-7

1918777-7

1938996-7

1918781-7

1918779-7

1918783-7

1938056-7

24

12

6754287-7

6754288-7

1918778-7

6828819-7

1918782-7

1918780-7

1918784-7

1938965-7

Violet

12

6

6754285-8

6754286-8

1918777-8

1938996-8

1918781-8

1918779-8

1918783-8

1938056-8

24

12

6754287-8

6754288-8

1918778-8

6828819-8

1918782-8

1918780-8

1918784-8

1938965-8

Rose

12

6

6754285-9

6754286-9

1918777-9

1938996-9

1918781-9

1918779-9

1918783-9

1938056-9

24

12

6754287-9

6754288-9

1918778-9

6828819-9

1918782-9

1918780-9

1918784-9

1938965-9

Slate

12

6

1-6754285-0 1-6754286-0

1-1918777-0

1-1938996-0

1-1918781-0

1-1918779-0

1-1918783-0

1-1938056-0

24

12

1-6754287-0

1-6754288-0

1-1918778-0

1-6828819-0

1-1918782-0

1-1918780-0

1-1918784-0

1-1938965-0

Aqua

12

6

1-6754285-1

1-6754286-1

1-1918777-1

1-1938996-1

1-1918781-1

1-1918779-1

1-1918783-1

1-1938056-1

24

12

1-6754287-1

1-6754288-1

1-1918778-1

1-6828819-1

1-1918782-1

1-1918780-1

1-1918784-1

1-1938965-1

Note: Table colors are for reference only.

Sc2_SECURENetworkSolutions_v1.indd   14

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-15

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

MPO SECURE Optical Fiber Cassettes

Part Number

SECURE 
Color

Fiber 

Count

Duplex 

Port 

Count

MT-RJ SECURE

LC SECURE

62.5 

µ

OM1

50 

µ

m OM2

XG OM3

50 

µ

m

Singlemode

62.5 

µ

OM1

50 

µ

m OM2

XG OM3

50 

µ

m

Singlemode

Red

12

6

6754285-2

6754286-2

1918777-2

1938996-2

1918781-2

1918779-2

1918783-2

1938056-2

24

12

6754287-2

6754288-2

1918778-2

6828819-2

1918782-2

1918780-2

1918784-2

1938965-2

Green

12

6

6754285-3

6754286-3

1918777-3

1938996-3

1918781-3

1918779-3

1918783-3

1938056-3

24

12

6754287-3

6754288-3

1918778-3

6828819-3

1918782-3

1918780-3

1918784-3

1938965-3

Blue

12

6

6754285-4

6754286-4

1918777-4

1938996-4

1918781-4

1918779-4

1918783-4

1938056-4

24

12

6754287-4

6754288-4

1918778-4

6828819-4

1918782-4

1918780-4

1918784-4

1938965-4

Yellow

12

6

6754285-5

6754286-5

1918777-5

1938996-5

1918781-5

1918779-5

1918783-5

1938056-5

24

12

6754287-5

6754288-5

1918778-5

6828819-5

1918782-5

1918780-5

1918784-5

1938965-5

Orange

12

6

6754285-6

6754286-6

1918777-6

1938996-6

1918781-6

1918779-6

1918783-6

1938056-6

24

12

6754287-6

6754288-6

1918778-6

6828819-6

1918782-6

1918780-6

1918784-6

1938965-6

Brown

12

6

6754285-7

6754286-7

1918777-7

1938996-7

1918781-7

1918779-7

1918783-7

1938056-7

24

12

6754287-7

6754288-7

1918778-7

6828819-7

1918782-7

1918780-7

1918784-7

1938965-7

Violet

12

6

6754285-8

6754286-8

1918777-8

1938996-8

1918781-8

1918779-8

1918783-8

1938056-8

24

12

6754287-8

6754288-8

1918778-8

6828819-8

1918782-8

1918780-8

1918784-8

1938965-8

Rose

12

6

6754285-9

6754286-9

1918777-9

1938996-9

1918781-9

1918779-9

1918783-9

1938056-9

24

12

6754287-9

6754288-9

1918778-9

6828819-9

1918782-9

1918780-9

1918784-9

1938965-9

Slate

12

6

1-6754285-0 1-6754286-0

1-1918777-0

1-1938996-0

1-1918781-0

1-1918779-0

1-1918783-0

1-1938056-0

24

12

1-6754287-0

1-6754288-0

1-1918778-0

1-6828819-0

1-1918782-0

1-1918780-0

1-1918784-0

1-1938965-0

Aqua

12

6

1-6754285-1

1-6754286-1

1-1918777-1

1-1938996-1

1-1918781-1

1-1918779-1

1-1918783-1

1-1938056-1

24

12

1-6754287-1

1-6754288-1

1-1918778-1

1-6828819-1

1-1918782-1

1-1918780-1

1-1918784-1

1-1938965-1

Note: Table colors are for reference only.

MPO SECURE Trunk Cable Assemblies, Plenum (OFNP)

FEATURES 

• 

Ten color-coded keyed designs limit improper connections in segregated networks

• 

MPO SECURE plugs only mate with MPO SECURE adapters of the same color

• 

Twelve (12) fi bers per MPO SECURE connector

• 

Easy installation—MPO SECURE plugs are push/pull connectors

• 

Plenum cables can be used in riser spaces

• 

Trunk cables come pre-tested and ready for immediate use with MPO SECURE 
plugs on both ends

• 

Pulling socks protect MPO SECURE terminations during installation

• 

Quick Ship available for MPO SECURE cable assemblies

• 

Standard lengths are in 10' increments from 10' to 300'

• 

Plug into cassettes found on pages 3-13

• 

See Spec 402-1008 for detailed information

ORDERING INFORMATION

Description

Part Number

12-Fiber

OM1 MPO SECURE to MPO SECURE

MPC-CzCzJ10xxxF-NN

OM2 MPO SECURE to MPO SECURE

MPC-CzCzJ20xxxF-NN

OM3 MPO SECURE to MPO SECURE

MPC-CzCzJ30xxxF-NN 

OM4 MPO SECURE to MPO SECURE

MPC-CzCzJ40xxxF-NN

24-Fiber

OM1 MPO SECURE to MPO SECURE

MPC-CzCzD10xxxF-SS

OM2 MPO SECURE to MPO SECURE

MPC-CzCzD20xxxF-SS

OM3 MPO SECURE to MPO SECURE

MPC-CzCzD30xxxF-SS

OM4 MPO SECURE to MPO SECURE

MPC-CzCzD40xxxF-SS

Note: z  = color:  B = Blue, N = Orange, G = Green, W = Brown, 
S = Slate, R = Red, Y = Yellow, V = Violet, P = Rose, A = Aqua, 
xxx = length in feet or meters: F=Feet
MPC- part numbers have pairs fl ipped. See spec 402-1008 for information on other fi ber paths

Sc2_SECURENetworkSolutions_v1.indd   15

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Fiber Products

2-16

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

ORDERING INFORMATION

Catalog Number

MP__ – __ __ __ __ __ __ __ __ __ __ __ – __ __

OM1

J1

12-fiber 3 mm interconnect, OFNP

11

12-fiber backbone, 1x12F, 3 mm 

interconnect subunit, OFN

D1

24 fiber backbone, 2x12F, 3 mm 

interconnect subunits, OFNP

OM3

J3

12-fiber 3 mm interconnect, OFNP

13

12-fiber backbone, 1x12F, 3 mm 

interconnect subunit, OFNP

D3

24 fiber backbone, 2x12F, 

3 mm interconnect subunits, OFNP

M3

24 fiber backbone, 1x12F, 3.8 mm 

interconnect subunits, OFNP

OM4

J4

12-fiber 3 mm interconnect, OFNP

14

12-fiber backbone, 1x12F, 3 mm 

interconnect subunit, OFNP

D4

24 fiber backbone, 2x12F, 3 mm 

interconnect subunits, OFNP

M4

24 fiber backbone, 1x12F, 3.8 mm 

interconnect subunits, OFNP

Singlemode

J5

12-fiber 3 mm interconnect, OFNP

15

12-fiber backbone, 1x12F, 3 mm 

interconnect subunit, OFNP

D5

 24 fiber backbone, 2x12F, 3 mm 

interconnect subunits, OFNP

M5

24 fiber backbone, 1x12F, 3.8 mm 

interconnect subunits, OFNP

* Higher fiber counts available upon request

OM2

J2

12-fiber 3 mm interconnect, OFNP

12

12-fiber backbone, 1x12F, 3 mm 

interconnect subunit, OFNP

D2

24 fiber backbone, 2x12F, 3 mm 

interconnect subunits, OFNP

Breakout Length

A

TFP

B

NGF

F

RMG

S

Standard

U

Custom length

XX

Custom dimension

Cable Jacket Color

0

Standard

C

Blue

N

Orange

G

Green

W

Brown

S

Slate

R

Red

Y

Yellow

V

Violet

P

Rose

A

Aqua

Cable Type

Use charts below

Assembly Length

001

Shortest possible length

999

Longest possible length

Unit of Measure

F

Feet

M

Meters

Performance/Polarity

C

Standard Performance Polarity C

A

Standard Performance Poloarity A

B

Standard Performance Polarity B

T

Optimate Polarity A

E

Optimate Polarity C

F

Optimate Polarity B

Connector A Type

N

12-fiber MPO w/o pins

P

12-fiber MPO w/pins

C

12-fiber MPO Secure w/o pins

E

12-fiber MPO Secure w/pins

Connector B Type

N

12-fiber MPO w/o pins

P

12-fiber MPO w/pins

C

12-fiber MPO Secure w/o pins

E

12-fiber MPO Secure w/pins

0

Stub/pigtail

Connector B Color

C

Non-secure

0

Red

B

Blue

G

Green

Y

Yellow

N

Orange

W

Brown

S

Slate

V

Violet

P

Rose

A

Aqua

Connector A Color

C

Non-secure

0

Red

B

Blue

G

Green

Y

Yellow

N

Orange

W

Brown

S

Slate

V

Violet

P

Rose

A

Aqua

Sc2_SECURENetworkSolutions_v1.indd   16

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Copper Products

2-17

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

SECURE Copper Connectivity

TE Connectivity's copper connectivity off ers premiere solutions with unique keying
technology to secure your network against unauthorized access. The RJ45 SECURE
solution is off ered in six diff erent colors allowing RJ45 SECURE plugs to mate with RJ45
SECURE jacks of the same color. The jacks are compatiable with any SL Series faceplate
latch design. The RJ45 Security Key Solution has a mechanical key which is required to
remove secured plugs and jacks and helps to protect against inadvertent disconnects
of critical systems. The RJ45 secuity key solution is compatible with any standard RJ45
interface used in panel, outlet areas, wireless LANs, security cameras and servers.

FEATURES

• 

Six color-coded keyed designs limit improper connections in segregated networks

• 

RJ45 SECURE plugs only mate with RJ45 SECURE jacks of the same color

• 

Confi gure faceplates with one or more RJ45 SECURE connectors to provide a
common access point to multiple segregated or secure networks

• 

Same thin profi le as standard RJ45 SL series jacks - easily snaps into SL series
modules, duplex mounting straps, patch panels, and enclosures

• 

May be used in straight or angled faceplate modules

• 

180° cable dress for easy termination

• 

Unshielded jacks also allow 90° cable dress

• 

Universal wiring label permits wiring to T568A or T568B

• 

Bend-limiting strain relief included with unshielded jacks

• 

UL Listed: E81956

• 

8-Position RJ45 SECURE modular jacks for 1-, 2-, 3-, and 4-pair applications

• 

Shielded and unshielded jacks

• 

Can be terminated with SL series modular jack termination tool 1725150-1

RJ45 SECURE SL Series Category 6 Modular Jacks

Terminated

Shielded Jack

Figure A

Part Number

Shielding

Rear Cable Entry

Figure

Red

Yellow

Green

Blue

Violet

Orange

Unshielded

90º or 180º

A

1479794-1

1479794-2

1479794-3

1479794-4

1479794-8

1479794-9

Shielded

180º

B

1479795-1

1479795-2

1479795-3

1479795-4

1479795-8

1479795-9

Note: Table colors are for reference only.

ORDERING INFORMATION

Figure B

Sc2_SECURENetworkSolutions_v1.indd   17

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Copper Products

2-18

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

FEATURES

• 

Six color-coded keyed designs limit improper connections in segregated networks

• 

Gray (universal key) available for use in testing

• 

RJ45 SECURE plugs only mate with RJ45 SECURE jacks of the same color

• 

See page 3-25 for color-matched snagless boots

• 

5 - 6 mm plug terminated with Pro-Crimper III hand-tool 354940-1 and
die set 1976200-2 or combination tool/die set 1976200-1

• 

6 - 7 mm plug terminated with Pro-Crimper III hand-tool 354940-1 and
die set 1976200-4 or combination tool/die set 1976200-3

RJ45 SECURE Category 6 Modular Plugs

Part Number

Conductor 
Type

Cable 

O.D.

Quantity 

Per Box

Red

Yellow

Green

Blue

Violet

Orange

Gray 
(Universally Keyed)

Standard

5-6 mm

100

5-1479802-3

5-1479804-3

5-1479806-3

5-1479808-3

5-1499675-3

5-1499677-3

5-1499679-3

6-7 mm

100

5-1499549-3

5-1499551-3

5-1499553-3

5-1499555-3

5-1499557-3

5-1499559-3

5-1499561-3

Solid

5-6 mm

100

5-1479803-3

5-1479805-3

5-1479807-3

5-1479809-3

5-1499676-3

5-1499678-3

5-1499680-3

6-7 mm

100

5-1499550-3

5-1499552-3

5-1499554-3

5-1499556-3

5-1499558-3

5-1499560-3

5-1499562-3

Note: Table colors are for reference only.

ORDERING INFORMATION

Sc2_SECURENetworkSolutions_v1.indd   18

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Copper Products

2-19

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

FEATURES

• 

Six color-coded keyed designs limit improper connections in segregated networks

• 

RJ45 SECURE plugs only mate with RJ45 SECURE jacks of the same color

• 

RJ45 SECURE assemblies have a standard plug on one end and a RJ45 SECURE
plug on the other end

• 

Color-matched snagless boots

• 

Universal wiring (T568A/T568B)

• 

26 AWG stranded conductors

• 

Shielded and unshielded cable assemblies

• 

Cable assemblies are riser-rated

RJ45 SECURE Category 6 Patch Cable Assemblies

Part Number

Length

Blue

Violet

Orange

Unshielded

Shielded

Unshielded

Shielded

Unshielded

Shielded

2' (0.61 m)

1499844-2

1499851-2

1499845-2

1499852-2

1499846-2

1499853-2

3' (0.91 m)

1499844-3

1499851-3

1499845-3

1499852-3

1499846-3

1499853-3

4' (1.22 m)

1499844-4

1499851-4

1499845-4

1499852-4

1499846-4

1499853-4

5' (1.52 m)

1499844-5

1499851-5

1499845-5

1499852-5

1499846-5

1499853-5

6' (1.83 m)

1499844-6

1499851-6

1499845-6

1499852-6

1499846-6

1499853-6

7' (2.13 m)

1499844-7

1499851-7

1499845-7

1499852-7

1499846-7

1499853-7

8' (2.44 m)

1499844-8

1499851-8

1499845-8

1499852-8

1499846-8

1499853-8

9' (2.74 m)

1499844-9

1499851-9

1499845-9

1499852-9

1499846-9

1499853-9

10' (3.05 m)

1-1499844-0

1-1499851-0

1-1499845-0

1-1499852-0

1-1499846-0

1-1499853-0

12' (3.66 m)

1-1499844-2

1-1499851-2

1-1499845-2

1-1499852-2

1-1499846-2

1-1499853-2

14' (4.27 m)

1-1499844-4

1-1499851-4

1-1499845-4

1-1499852-4

1-1499846-4

1-1499853-4

16' (4.88 m)

1-1499844-6

1-1499851-6

1-1499845-6

1-1499852-6

1-1499846-6

1-1499853-6

20' (6.10 m)

2-1499844-0

2-1499851-0

2-1499845-0

2-1499852-0

2-1499846-0

2-1499853-0

25' (7.62 m)

2-1499844-5

2-1499851-5

2-1499845-5

2-1499852-5

2-1499846-5

2-1499853-5

30' (9.14 m)

3-1499844-0

3-1499851-0

3-1499845-0

3-1499852-0

3-1499846-0

3-1499853-0

40' (12.19 m)

4-1499844-0

4-1499851-0

4-1499845-0

4-1499852-0

4-1499846-0

4-1499853-0

50' (15.24 m)

5-1499844-0

5-1499851-0

5-1499845-0

5-1499852-0

5-1499846-0

5-1499853-0

Note: Table colors are for reference only.

Part Number

Length

Red

Yellow

Green

Unshielded

Shielded

Unshielded

Shielded

Unshielded

Shielded

2' (0.61 m)

1499841-2

1499848-2

1499842-2

1499849-2

1499843-2

1499850-2

3' (0.91 m)

1499841-3

1499848-3

1499842-3

1499849-3

1499843-3

1499850-3

4' (1.22 m)

1499841-4

1499848-4

1499842-4

1499849-4

1499843-4

1499850-4

5' (1.52 m)

1499841-5

1499848-5

1499842-5

1499849-5

1499843-5

1499850-5

6' (1.83 m)

1499841-6

1499848-6

1499842-6

1499849-6

1499843-6

1499850-6

7' (2.13 m)

1499841-7

1499848-7

1499842-7

1499849-7

1499843-7

1499850-7

8' (2.44 m)

1499841-8

1499848-8

1499842-8

1499849-8

1499843-8

1499850-8

9' (2.74 m)

1499841-9

1499848-9

1499842-9

1499849-9

1499843-9

1499850-9

10' (3.05 m)

1-1499841-0

1-1499848-0

1-1499842-0

1-1499849-0

1-1499843-0

1-1499850-0

12' (3.66 m)

1-1499841-2

1-1499848-2

1-1499842-2

1-1499849-2

1-1499843-2

1-1499850-2

14' (4.27 m)

1-1499841-4

1-1499848-4

1-1499842-4

1-1499849-4

1-1499843-4

1-1499850-4

16' (4.88 m)

1-1499841-6

1-1499848-6

1-1499842-6

1-1499849-6

1-1499843-6

1-1499850-6

20' (6.10 m)

2-1499841-0

2-1499848-0

2-1499842-0

2-1499849-0

2-1499843-0

2-1499850-0

25' (7.62 m)

2-1499841-5

2-1499848-5

2-1499842-5

2-1499849-5

2-1499843-5

2-1499850-5

30' (9.14 m)

3-1499841-0

3-1499848-0

3-1499842-0

3-1499849-0

3-1499843-0

3-1499850-0

40' (12.19 m)

4-1499841-0

4-1499848-0

4-1499842-0

4-1499849-0

4-1499843-0

4-1499850-0

50' (15.24 m)

5-1499841-0

5-1499848-0

5-1499842-0

5-1499849-0

5-1499843-0

5-1499850-0

Note: Table colors are for reference only.

ORDERING INFORMATION

Sc2_SECURENetworkSolutions_v1.indd   19

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Copper Products

2-20

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

FEATURES

• 

Works with standard RJ45 jacks

• 

Prevents unauthorized port connections

• 

Prevents disconnection from active devices

• 

Lock to RJ45 modular jacks

• 

Can be used in public areas or conference rooms

• 

1871456-1 key/lock pairs are randomly selected from 100 diff erent key
numbers (numbered 800-899)

• 

1871456-2, -3, and -4 use specifi c reserved key/lock pair number 456A

• 

RoHS compliant

Security Key Plug

Description

Included Keys

Part Number

Security Key Plug with

2 Keys, random number

1871456-1

2 Keys, reserved number

1871456-2

Security Key Plug 

reserved number

None, for use with 1871456-4

1871456-3

Key for Reserved Number Security Key Plug

1871456-4

FEATURES

• 

Works with standard RJ45 plugs

• 

Prevents unauthorized port connections

• 

Prevents disconnection from active devices

• 

Lock to RJ45 modular plugs

• 

Can be used to secure un-used patch cords

• 

Uses specifi c reserved key/lock pair number 456A

• 

RoHS compliant

Security Key Jack

Description

Included Keys

Part Number

Security Key Jack

2 Keys, reserved number

1-1871456-2

ORDERING INFORMATION

ORDERING INFORMATION

Sc2_SECURENetworkSolutions_v1.indd   20

12/7/12   3:35 PM

Tyco-catalog-AMP-2013-html.html
background image

SECURE Network Solutions

Copper Products

2-21

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SECURE NETW

ORK SOL

UTIONS

Security Key Plug

Description

Included Keys

Part Number

Security Key Plug with

2 Keys, random number

1871456-1

2 Keys, reserved number

1871456-2

Security Key Plug 

reserved number

None, for use with 1871456-4

1871456-3

Key for Reserved Number Security Key Plug

1871456-4

Security Key Jack

Description

Included Keys

Part Number

Security Key Jack

2 Keys, reserved number

1-1871456-2

FEATURES

• 

Works with standard RJ45 ports

• 

Prevents disconnection from active devices

• 

Prevent unauthorized disconnection

• 

Can be used for secure connections (e.g. server lines)

• 

Uses specifi c reserved key/lock pair number 456A
(two keys included)

• 

RoHS compliant

• 

Category 6 patch cables are backwardly compatible
with Category 5e components

• 

Security patch cord color:

Cat 6: black

Cat 6A F/UTP: blue

Security Key Patch Cord

Part Number

Category

Length

Locks on Both Ends

Locks on one End

Cat 6 Unshielded

1' (0.30 m)

2111179-1

2111225-1

2' (0.61 m)

2111179-2

2111225-2

3' (0.91 m)

2111179-3

2111225-3

4' (1.22 m)

2111179-4

2111225-4

5' (1.52 m)

2111179-5

2111225-5

6' (1.83 m)

2111179-6

2111225-6

7' (2.13 m)

2111179-7

2111225-7

8' (2.44 m)

2111179-8

2111225-8

9' (2.74 m)

2111179-9

2111225-9

10' (3.05 m)

1-2111179-0

1-2111225-0

12' (3.66 m)

1-2111179-2

1-2111225-2

14' (4.27 m)

1-2111179-4

1-2111225-4

16' (4.88 m)

1-2111179-6

1-2111225-6

18' (5.49 m)

1-2111179-8

1-2111225-8

20' (6.10 m)

2-2111179-0

2-2111225-0

Cat 6A Shielded

1' (0.30 m)

2111190-1

2111236-1

2' (0.61 m)

2111190-2

2111236-2

3' (0.91 m)

2111190-3

2111236-3

4' (1.22 m)

2111190-4

2111236-4

5' (1.52 m)

2111190-5

2111236-5

6' (1.83 m)

2111190-6

2111236-6

7' (2.13 m)

2111190-7

2111236-7

8' (2.44 m)

2111190-8

2111236-8

9' (2.74 m)

2111190-9

2111236-9

10' (3.05 m)

1-2111190-0

1-2111236-0

12' (3.66 m)

1-2111190-2

1-2111236-2

14' (4.27 m)

1-2111190-4

1-2111236-4

16' (4.88 m)

1-2111190-6

1-2111236-6

18' (5.49 m)

1-2111190-8

1-2111236-8

20' (6.10 m)

2-2111190-0

2-2111236-0

Cat 6A Patch Cord

Cat 6 Patch Cord

ORDERING INFORMATION

Sc2_SECURENetworkSolutions_v1.indd   21

12/7/12   3:36 PM

Tyco-catalog-AMP-2013-html.html
background image

3-1

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Category 6a Products .................................................................................3-3
  Category 6A Twisted Pair Cable ........................................................3-3 
  Category 6A Patch Panels ....................................................................3-7
  Category 6A Modular Jacks .................................................................3-9
  Category 6A Cable Assemblies .........................................................3-11
  Category 6A Termination Blocks.......................................................3-13
Category 6 Products ....................................................................................3-16
  Category 6 Twisted Pair Cable ...........................................................3-16
  Category 6 Patch Panels ........................................................................3-21
  Category 6 Modular Jacks ....................................................................3-23
  Category 6 Modular Plugs and Plug Boots .................................3-24
  Category 6 Cable Assemblies .............................................................3-25
  Category 6 Termination Blocks ..........................................................3-26
Category 5e Products .................................................................................3-32
  Category 5e Twisted Pair Cable .........................................................3-32
  Category 5e Patch Panels .....................................................................3-38
  Category 5e Modular Jacks ..................................................................3-40
  Category 5e Modular Plugs and Plug Boots ...............................3-42
  Category 5e Cable Assemblies ...........................................................3-44
  Category 5e Termination Blocks ........................................................3-45
Copper Trunk Solutions ..............................................................................3-51
  MRJ21 Cable Assemblies ........................................................................3-51
  Sigma-Link .....................................................................................................3-60
Specialty Products ........................................................................................3-63
  Universal Connectivity Platform ........................................................3-63
  High Speed Copper Cable Assemblies ..........................................3-68
  Video Distribution System .....................................................................3-71
  Media Converters and Switches .........................................................3-73

Copper Products

Sc3_Copper_01_6a_v1.indd   1

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

3-2

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper Products 

(Continued)

  Patch Panels ..................................................................................................3-79
  Jacks and Couplers ...................................................................................3-86
  Modular Plugs ...............................................................................................3-88
  Feed-Thru Termination Block  

  System and Accessories .........................................................................3-89

  Zone Cabling .................................................................................................3-94

Copper Accessories ......................................................................................3-101

  Cable wrap, Clamps, Ties, Accessories ...........................................3-101

  Identification Labels and Accessories .............................................3-103

Copper Tooling ................................................................................................3-115

Copper Solution Reference Guide ........................................................3-128

The industry embraces copper cabling solutions for better 
performance and noise immunity—critical elements in any  
network infrastructure. TE offers a broad portfolio of  
innovative, high-performance copper solutions comprised of 
industry-leading technology and backed by a 25-year performance 
and component warranty.

Combining products from our AMP NETCONNECT, KRONE and 
TrueNet portfolios, TE’s copper solutions cover all applications from 
1 GbE to 10 GbE. Shielded, unshielded and pre-terminated options 
provide our customers with the industry’s strongest range of fully 
warranted solutions from the desktop to the data center.

Sc3_Copper_01_6a_v1.indd   2

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-3

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

C

OPPER

 

640 Series Category 6A F/UTP Twisted Pair Cable

640 Series Cat 6A F/UTP cables off er superior noise immunity at higher 
frequencies where applications like 10 Gigabit Ethernet reside, without hampering 
performance. Combined with outstanding margins on critical parameters such as 
crosstalk and return loss, TE640 F/UTP cables are an excellent choice for your 
10 gig network. Along with unsurpassed electrical performance, 640 F/UTP cables 
feature an industry-low outside diameter for increased fi ll rates, driving down 
installation costs.

FEATURES

• 

Meets or exceeds the channel specifi cations of ANSI/TIA-568-C.2 Category 
6A and Amendment 1 to ISO/IEC 11801:2002 Class EA up to 500 MHz when 
used as a component in a properly installed TE Connectivity F/UTP channel

• 

Foil shield for increased signal isolation

• 

Resistant to alien crosstalk

• 

AirES patented design on CMP for higher throughput and reduced size

• 

Independently tested by Intertek ETL SEMKO third party testing services

• 

Meets or exceeds all requirements for IEEE 802.3an 10 Gigabit Ethernet

• 

RoHS compliant

UL/NEC Rating

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Part number

CMP

4

1000' reel

0.265"

23

42

TE640PF-XX02

CMR

4

1000' reel

0.265"

24

42

TE640RF-XX02

cat6 ftp

Jacket

Foil Shield

Drain Wire

Insulation

Conductor

ORDERING INFORMATION

The following jacket colors are available. Replace "XX" with
BL-Blue 

WT-White 

GY-Gray 

YL-Yellow 

GN-Green

BK-Black  

RD-Red  

OR-Orange 

VT-Violet 

BN-Brown

Additional reel sizes available, please contact TE Customer Service.

Sc3_Copper_01_6a_v1.indd   3

12/7/12   11:52 AM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-4

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

UL/NEC Rating

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Part Number

CMP

4

1000' reel

0.285"

23

41

TE640P-XX02

CMR

4

1000' reel

0.295"

23

41

TE640R-XX02

The following jacket colors are available. Replace "XX" with
BL-Blue 

WT-White 

GY-Gray 

YL-Yellow 

GN-Green

BK-Black  

RD-Red  

OR-Orange 

VT-Violet 

BN-Brown

Additonal reel sizes available, please contact TE Customer Service.

ORDERING INFORMATION

640 Series Category 6A U/UTP Twisted Pair Cable

TE Connectivity's 640 Series UTP cable enables 10 Gigabit Ethernet performance 
with an industry-low outside diameter. The 640 Series Category 6A plenum 
cables feature the best in class AirES technology. This patented design saves 
as much as 32% of the available space in cable runs and is a key component of 
the TE structured cabling system. The smaller diameter also saves space in the 
communications closet, reduces the amount of cable management accessories 
required and lowers the risk associated with fi re and smoke in the plenum space. 
TE's 640 cable also features a patented oblique elliptical off set fi ller to minimize 
alien crosstalk.

FEATURES

• 

Unique oblique elliptical off set fi ller for improved alien crosstalk

• 

AirES patented design on CMP for higher throughput and reduced size 

• 

Manufactured with lead-free materials

• 

Meets or exceeds all requirements for IEEE 802.3an 10 Gigabit Ethernet

• 

RoHS compliant

Sc3_Copper_01_6a_v1.indd   4

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-5

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Outback 640 Series, Outdoor Category 6A UTP Cable

• 

4-pair, 23 AWG Category 6A cable designed for outdoor use

• 

Excellent transmission and weather resistant properties

• 

Black Polyethylene jacket for weather resistance  

• 

Oblique elliptical off set fi ller to minimize alien crosstalk

• 

Performance characterized to 650 MHz

• 

Meets or exceeds all requirements for 10 Gigabit Ethernet

• 

Intended for outdoor installation, in buried conduit or as aerial cable

• 

Not intended for wet applications

ORDERING INFORMATION

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Part Number

4

1000' Reel

0.298"

23

39

TE640OSP-BK02

Sc3_Copper_01_6a_v1.indd   5

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-6

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Wooden Reels

Ring Conductor

Tip Conductor

Twisted Pair

Note:  Unless otherwise specifi ed, 
all lengths are 1000 feet (305 meters). 
Other lengths and colors available. 
Contact TE customer service.

TWISTED PAIR CABLE TEMPERATURES

Category

Condition

Riser/Plenum

Cat 6A

Storage

 -4 – 176° F (-20 – 80° C)

Operating

 -4 – 140° F (-20 – 60° C)

Installation

 41 – 122° F (5 – 50° C)

4-Pair Conductor Color Code

Pair

Jacket Color

1

Tip

 White

Ring

 Blue

2

Tip

White

Ring

Orange

3

Tip

White

Ring

Green

4

Tip

White

Ring

Brown

Specifications

Sc3_Copper_01_6a_v1.indd   6

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-7

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CO

PPER

 

Category 6A Patch Panels

TE Connectivity's Category 6A AMP-TWIST patch panels deliver the next 
generation of 10 GbE performance and continue the evolution of high-density 
solutions for the data center and LAN environments while meeting all the 
requirements for Category 6A ANSI/TIA and ISO standards. These are available in 
several different styles and port configurations. This includes: shielded, unshielded, 
standard flat, fixed angled, 24-port and 48-port configurations along with TE's 
patented dynamic angled panels. 

FEATURES FOR STANDARD AND ANGLED

• 

Meets or exceeds the channel specifications of ANSI/TIA-568-C.2 Category 6A 
and Amendment 1 to ISO/IED 11801:2002 Class EA up to 500 MHz when used 
as a component in a properly installed TE Connectivity XG F/UTP or 
U/UTP channel

• 

Meets or exceeds all requirements for IEEE 802.3an 10 GbE

• 

Ports may be individually replaced

• 

Standard and angled panels are packaged unloaded with jacks bagged 
separately for termination with SL Series jack termination tool

• 

Front load removable 6 pack modules

• 

Labels and label covers included

• 

Accommodates icons (sold separately)

• 

Standard and angled panels feature integrated bonding bar makes bonding 
simple and requires no extra steps in shielded applications

• 

UL1863 listed and Category 6A performace verified

• 

RoHS compliant

FEATURES FOR DYNAMIC ANGLED

• 

Patented angle right/left eases stress on patch cords allowing for improved 
cable management

• 

Low profile dynamic angling allows for greater flexibility and use in cabinet 
environments

• 

Universal wiring label for easy termination of either T568A/B

• 

Conductors can be terminated with either a KRONE or 110 tool

• 

45 degree silver-plated IDCs provide secure, reliable gas-tight connection

• 

Includes adhesive paper labels for station identification

• 

Universal wiring label for easy termination of either T568A/B

• 

Patch panels are designed to support Gigabit Ethernet transmission speeds

• 

Rear wire manager included

• 

UL 1863 listed and Category 6A performance verified

• 

RoHS compliant

Sc3_Copper_01_6a_v1.indd   7

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-8

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CO

PPER

 

Figure A

Figure B

Figure C

Footprint

Shielding

Port Count

Height

Width

Figure

Part Number

Standard

Shielded

24

1RU (1.75")

19.0"

1933319-2

48

2RU (3.50")

19.0"

A

1933320-2

Unshielded

24

1RU (1.75")

19.0"

2111570-1

48

2RU (3.50")

19.0"

A

2111571-1

Angled

Shielded

24

1RU (1.75")

19.0"

B

1933321-2

48

2RU (3.50")

19.0"

1933322-2

Unshielded

24

1RU (1.75")

19.0"

B

2111572-1

48

2RU (3.50")

19.0"

2111573-1

Dynamic 
Angled

Unshielded

24

1RU (1.75")

19.0"

C

PP24AC6AT

48

2RU (3.50")

19.0"

PP48AC6AT

ORDERING INFORMATION

Standard and Angled Panels

Sc3_Copper_01_6a_v1.indd   8

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-9

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CO

PPER

 

Category 6A Modular Jacks

TE Connectivity's AMP NETCONNECT Category 6A AMP-TWIST modular jacks 
deliver the next generation of 10G performance and continue the evolution of 
high-density solutions for the data center and LAN environments while meeting 
all the requirements for Category 6A ANSI/TIA and ISO standards. The F/UTP 
jack offers superior noise immunity to eliminate alien crosstalk and RFI/EMI while 
offering integrated mechanical bonding and grounding through normal installation 
practices. The U/UTP jack utilizes superior technology to reduce alien crosstalk 
noise to enhance overall performance. The AMP-TWIST termination technology 
provides for the fastest most reliable termination on the market. The modular jacks 
contain integrated cutting blades to allow all four pairs of a four pair cable to be 
terminated at one time. Universal wiring labels permit termination to either T568A 
or T568B wiring patterns.

FEATURES

• 

Meets or exceeds the channel specifications of ANSI/TIA-568-C.2 Category 6A 
and Amendment 1 to ISO/IEC 11801:2002 Class EA up to 500 MHz when used 
as a component in a properly installed AMP NETCONNECT XG channel

• 

Termination time:  about 90 seconds (using AMP NETCONNECT SL series 
termination tool, without lacing fixture – 1725150-3

• 

Meets or exceeds all requirements for IEEE 802.3an 10 GbE

• 

Easy installation

• 

Integrated strain relief and shield clamp

• 

Integrated dust cover option

• 

Re-usable

• 

Universal wiring label permits wiring to T568A or T568B

• 

8-Position RJ45 modular jacks for 1, 2, 3, and 4-Pair applications

• 

RoHS compliant

• 

UL1863 listed and Category 6A performace verified

Sc3_Copper_01_6a_v1.indd   9

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-10

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CO

PPER

 

Description

Shielding

Entry

Dust Cover Option

Figure Part Number

Cat 6A F/UTP

Shielded

Rear

without Dust Cover

A

1711342-2

with clear Dust Cover

1711160-2

Side

without Dust Cover

B

1711343-2

with clear Dust Cover

1711295-2

Cat 6A U/UTP

Unshielded

Rear

without Dust Cover

C

1933476-X

with clear Dust Cover

2111676-X

ORDERING INFORMATION

Note: Replace -X in Cat6 U/UTP part numbers with corresponding color number as follows:
(EX: 1933476-x for blue and 1-1933476-3 for Alpine White)
-1 = Almond 

-5 = Orange  

-8 = Yellow 

-1--1 = Electrical Ivory

-2 = Black 

-6 = Blue 

-9 = Green 

-1--3 = Alpine White

-4 = Gray 

-7 = Red 

 -1--0 = Violet

Figure A

Figure C

Figure B

Sc3_Copper_01_6a_v1.indd   10

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-11

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Category 6A Shielded Cable Assemblies

TE Connectivity's Category 6A shielded patch cable assemblies are manufactured 
using patented techniques that create consistent performance superior to standard 
cable assemblies. TE Connectivity's Category 6A shielded cable assemblies 
are CM (riser) rated and constructed using colored, stranded cable and clear 
polycarbonate snagless boots.

FEATURES

• 

Meets or exceeds the channel specifi cations of ANSI/TIA-568-C.2 Category 
6A shielded and Amendment 1 to ISO/IED 11801:2002 Class EA up to 500 MHz 
when used as a component in a properly installed TE F/UTP channel

• 

Meets or exceeds all requirements for IEEE 802.3an 10 GbE

• 

Clear, fl exible, strain relief boot maintains proper 
bend radius to ensure peak performance

• 

Non-plenum (CM rated)

• 

4-Pair stranded shielded conductors

• 

Universal wiring (T568A/T568B)

• 

RoHS compliant

ORDERING INFORMATION 

Description                                       

Part Number

RJ45 to RJ45 
patch cord

T568B

TCPC-6ARFVB-XXYYF

T568B

TCPC-6ARFVA-XXYYF

Replace X for color: 
0 = White 

3 = Yellow

1 = Red 

4 = Green

2 = Blue 

6 = Gray

Replace YY for length: 
04 = 4' 

15 = 15'

07 = 7'  

25 = 25'

10 = 10'  

50 = 50"

Contact TE for information on additional colors and custom lengths.

Sc3_Copper_01_6a_v1.indd   11

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-12

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CO

PPER

 

Category 6A U/UTP Cable Assemblies

FEATURES

• 

Meets or exceeds performance requirements ANSI/TIA-568-C.2 standards

• 

Copper conductors in the cable pairs are stranded for superior flexibility  
and compacted to a near-round shape for optimum signal strength 

• 

Snag-less plug design with built-in strain relief

• 

UL 1863 safety rating

Description

Part Number

RJ45 to RJ45 patch cord

568B wiring

TCPC-6ARUVB-XXYY

568A wiring

TCPC-6ARUVA-XXYY

Replace X for color: 
0 = White 

3 = Yellow

1 = Red 

4 = Green

2 = Blue 

6 = Gray

Replace YY for length: 
04 = 4' 

15 = 15'

07 = 7'  

25 = 25'

10 = 10'  

50 = 50"

Contact TE for information on additional colors and custom lengths.

Sc3_Copper_01_6a_v1.indd   12

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-13

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CO

PPER

 

Category 6A 8-pair and 20-pair Termination Blocks

TE Connectivity's HighBand cross connect solution allows for maximum network 
throughput to support 10 GbE and most advanced networks. The solution is comprised 
of high-performance disconnection modules, user friendly cable management and 
innovative anti-snag patch cords. It is the ideal cabling solution for companies who 
require efficiency, guaranteed performance and appealing aesthetics. The solution is 
based on Patch-by-Exception, which is a unique termination technology that is ideally 
suited for VoIP networks and offers material, installation and operational cost savings, 
making it a compelling alternative to traditional RJ45 products. TE's products maintain 
superior connectivity during hundreds of re-terminations and deliver the best electrical 
performance in the industry.

FEATURES

• 

Meets performance requirements of ANSI/TIA-568-C.2 standards

• 

45-degree silver-plated IDCs provide secure, reliable gas-tight connections

• 

Color-coded for ease of termination

• 

Modules are terminated with the standard KRONE termination tools, and may also 
be terminated with a 110 tool

• 

Four-pair to four-pair patch cords are available for Patch-by-Exception installations

• 

Four-pair to RJ45 cords are available to interface with network and other equipment

• 

Center test port allows for circuit monitoring without service disruption 

• 

Unique Patch-by-Exception functionality saves time and money while improving 
performance and aesthetics

• 

Eight-pair disconnect module design for use with TE TrueNet universal mounting 
system (UMS) and type 105 rod-mount bracket

ORDERING INFORMATION 

Category 6A 8 pair block field assembly kit

Color

Dimensions

Part Number

80-pair (20 port) kit

including black universal mounting kit
Supports field termination of (20) 4 pair cables.  
Includes (10) 8-pair Category 6A blocks, (2) horizontal wire 
managers, (1) black or gray universal mounting bracket and 
(1) type 105 label holder with label and protective cover

Black

14.75" x 8.25" x 5.25"  

(374.7 mm x 209.6 mm x 33.4 mm)

6636 1 598-46

80-pair (20 port) kit

including gray universal mounting kit  
Supports field termination of (20) 4 pair cables.  
Includes (10) 8-pair Category 6A blocks, (2) horizontal wire 
managers, (1) black or gray universal mounting bracket and 
(1) type 105 label holder with label and protective cover

Gray

14.75" x 8.25" x 5.25"  

(374.7 mm x 209.6 mm x 33.4 mm)

6636 1 598-06

Disconnection Module, 8-pair

6468 5 070-00

Sc3_Copper_01_6a_v1.indd   13

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-14

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Description

Part Number

12-way Cable Management Kit

    Includes (2) cable management rings and (1) cover

6450 1 103-10

  

Cable Management Rings (2)

6450 2 156-20

Cover (1)

6450 2 158-20

Cable Troughs

    Cable Trough Top (1)

6450 2 157-10

    Cable Trough Bottom (1)

6450 2 157-20

HighBand Cable Management

The cable management rings control vertical cable management between frames, 
ensuring that cables do not interfere when adds, moves and changes occur. The 
cable manager is ideal for high-density or heavily patched installations and provides 
a neat, clean finish to the HighBand

 

system. 

Cable troughs mounted on the top and bottom of each frame ensure superior cable 
management and correct bend radius between frames.

Vertical Management Cover

Cable Management Rings

Top Cable Trough

Bottom Cable Trough

ORDERING INFORMATION

ORDERING INFORMATION 

Description

Part Number

12-position termination block and mounting kit

Includes: stainless steel 12-position mounting frame; 12 Category 6A 
modules with rear cable management, each module accommodating 
(5) 4-pair Category 6A cables; 12 label holders

6450 1 107-01

Category 6A Termination Blocks (Continued)

Sc3_Copper_01_6a_v1.indd   14

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6A Products

3-15

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CO

PPER

 

Category 6A 8-pair and 20-pair Termination Block Patch Cords 
 

Impedance matched for use in TrueNet

 

structured cabling systems; these Category 

6A termination block patch cords exceed all performance requirements for 
Augmented Category 6. These cords allow direct patching capability between 
Category 6A 8-pair and 20-pair blocks or patching from a Category 6A termination 
block to an active device or an RJ45 patch panel. The plug is designed with 
integrated strain relievers that prevent the cable from moving at the termination 
point when the cable is flexed, safeguarding circuit integrity and guaranteeing 
maximum performance.

Description

Part Number

Category 6A 4-pair to Category 6A 4-Pair 

 

Category 6A 4-Pair to Category 6A 4-Pair wired 568B

TP6ATH-XXYY

 

Category 6A 4-Pair to Category 6A-Pair wired 568A

TP6ATH0XXYY

Category 6A 4-pair to RJ45

 

Category 6A 4-Pair to RJ45 Plug wired 568B

TP6ATB-XXYY

 

Category 6A 4-Pair to RJ45 Plug wired 568A

TP6ATB0XXYY

Sub XX for color: BL=Blue, BK=Black, GY=Gray, RD=Red, GN=Green, YL=Yellow, WT=White  
Call TE for additional colors
Sub YY for length: 04= 4 feet, 07= 7 feet, 10=10 feet, 15=15 Feet, 25=25 feet, 50=50 feet  
Call TE for additional lengths

ORDERING INFORMATION

FEATURES

• 

Meets or exceeds TIA/EIA and ISO Augmented Category 6 requirements 

• 

Protective shroud to assist in protecting the user from electrical transfer on 
the contacts 

• 

Impedance matched patch cord for maximum throughput 

• 

Flexible strain relief boot maintains proper bend radius to ensure peak performance 

• 

UL 1863 listed

• 

Durable design to be in operation beyond 25-year product warranty

Sc3_Copper_01_6a_v1.indd   15

12/7/12   3:23 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-16

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

C

OPPER

 

Category 6 Twisted Pair Cable

TE Connectivity off ers a variety of Category 6 cables designed to meet your 
performance needs while providing options for diff ering budgetary requirements.  
620 and 630 series CMP cables utilize TE's patented AirES cable technology that 
improves data throughput, saves space and eases installation. Through a unique 
design and advanced manufacturing techniques we are able to build AirES cable 
using air as a conductor insulator. This groundbreaking process results in a cable that 
incorporates superior performance while reducing overall size.

630 Series, Category 6E UTP Cable

• 

TE's highest performing Category 6 cable 

• 

Performance characterized to 600 MHz

• 

AirES patented design on CMP for higher throughput and reduced size

• 

12 dB NEXT performance above Category 6

• 

Star fi ller for electrical performance

• 

Meets or exceeds ANSI/TIA-568-C.2 Category 6 and ISO 11801: 
2002 Class E specifi cations

• 

Independently verifi ed by Intertek ETL SEMKO testing services

• 

Exceeds all requirements for Gigabit Ethernet

• 

RoHS compliant

ORDERING INFORMATION

UL/NEC 
Rating

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Part Number

CMP

4

1000' Reel in box

0.212"

23

32

TE630P-XXRB

1000' Reel

30

TE630P-XX02

CMR

4

1000' Reel in box

0.235”

24

33

TE630R-XXRB

1000' Reel

31

TE630R-XX02

The following jacket colors are available. Replace XX with: 

BL=Blue  

WT=White  

GY=Gray 

YL=Yellow  

GN=Green  

BK=Black  

RD=Red  

OR=Orange 

VT=Violet 

BN=Brown

Additional red sizes available, please contact TE Customer Service.  

 

  

Jacket

Core Filler

Conductor

Insulation

Cat6e

Sc3_Copper_02_6_v1.indd   16

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-17

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

C

OPPER

 

620 Series, Category 6 UTP Cable

FEATURES

• 

AirES cable patented design on CMP for higher throughput

• 

Performance characterized to 600 MHz

• 

7 dB NEXT performance above Category 6

• 

Meets or exceeds ANSI/TIA-568-C.2 Category 6 and 
ISO Class E 11801: 2002 specifi cations

• 

Available in side-by-side confi guration

• 

Independently verifi ed by Intertek ETL SEMKO testing services

• 

Exceeds all requirements for Gigabit Ethernet

• 

RoHS compliant

Jacket

Nominal Diameter

0.206”

Conductor

Insulation

Core: 4 pairs, cabled together

Pairs: Twisted with different lays

Filler

ORDERING INFORMATION

UL/NEC 
Rating

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Part Number

CMP

4 Pair

1000' Reel in box

0.215"

23

31

TE620P-XXRB

1000' Pull box

28

TE620P-XXll

1000' Reel

28

TE620P-XX02

4 Pair Side-by-Side

1000' Reel

0.215" x 0.430"

59

TE620PX2-XX02

CMR

4 Pair

1000' Reel in box

0.210”

24

31

TE620R-XXRB

1000' Pull box

28

TE620R-XXll

1000' Reel

28

TE620R-XX02

4 Pair Side-by-Side

1000' Reel

0.210" x 0.435"

59

TE620RX2-XX02

The following jacket colors are available. Replace "XX" with
BL-Blue 

WT-White 

GY-Gray 

YL-Yellow 

GN-Green

BK-Black  

RD-Red  

OR-Orange 

VT-Violet 

BN-Brown

Additional reel sizes available, please contact TE Customer Service.

Sc3_Copper_02_6_v1.indd   17

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-18

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

C

OPPER

 

• 

4-pair, 23 AWG Category 6 cable designed for outdoor use

• 

Excellent transmission and weather resistant properties

• 

Polyethylene jacket for weather resistance

• 

Performance characterized to 600 MHz

• 

Meets or exceeds all requirements for Gigabit Ethernet

• 

Intended for outdoor installation, in buried conduit or as aerial cable

• 

Not intended for wet applications

• 

RoHS compliant

Outback 620 Series, Outdoor Category 6 UTP Cable

ORDERING INFORMATION

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Color

Part Number

4

1000' Reel

0.250”

23

29

Black

TE6200SP-BK02

3000' Reel

92

TE6200SP-BK06

Additional reel sizes available, please contact TE Customer Service.

Sc3_Copper_02_6_v1.indd   18

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-19

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

C

OPPER

 

610 Series, Category 6 UTP Cable 

• 

Performance characterized to 400 MHz

• 

Meets ANSI/TIA-568-C.2 Category 6 and 
ISO Class E 11801: 2002 specifi cations

• 

Exceeds all requirements for Gigabit Ethernet

• 

RoHS compliant

• 

Independently verifi ed by Intertek ETL SEMKO testing services

ORDERING INFORMATION

UL/NEC 
Rating

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Part Number

CMP

4

1000' Pull box

0.210”

24

24

TE610P-XXII

1000' Reel

TE610P-XX02

3000' Reel

82

TE610P-XX06

CMR

4

1000' Pull box

0.210”

24

24

TE610R-XXII

1000' Reel

TE610R-XX02

3000' Reel

82

TE610R-XX06

Jacket

Nominal Diameter

0.210″

Conductor

Insulation

Core: 4 pairs, cabled together

Pairs: Twisted with different lays

Filler

The following jacket colors are available. Replace "XX" with
BL-Blue 

WT-White 

GY-Gray 

YL-Yellow 

GN-Green

BK-Black  

RD-Red  

OR-Orange 

VT-Violet 

BN-Brown

Additional reel sizes available, please contact TE Customer Service.

Sc3_Copper_02_6_v1.indd   19

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-20

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

C

OPPER

 

Note: Unless otherwise specifi ed, all lengths are 1000 feet (305 meters). Other lengths 
and colors available. Call for details. Package types are listed in each chart.

II = Pull Box

RB = Reel-in-a-Box

Ring Conductor

Tip Conductor

Twisted Pair

Pair

Jacket Color

1

Tip

 White

Ring

 Blue

2

Tip

White

Ring

Orange

3

Tip

White

Ring

Green

4

Tip

White

Ring

Brown

4-PAIR CONDUCTOR COLOR CODE

Twisted Pair Cable Packaging Reference

Category

Condition

Riser/Plenum

Cat 6

Storage

 -4 – 176° F (-20 – 80° C)

Operating

 -4 – 140° F (-20 – 60° C)

Installation

 41 – 122° F (5 – 50° C)

TWISTED PAIR CABLE TEMPERATURES

02 = Plastic Reels

Sc3_Copper_02_6_v1.indd   20

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-21

www.te.com/EnterpriseNetworks 

  +1-800-553-0938  Fax: 

1-717-986-7406  1/13 313948AE

C

OPPER

 

Category 6 Patch Panels

TE Connectivity patch panels are off ered in several diff erent styles and port 
confi gurations. This includes standard fl at panels, fi xed angled panels and TE's 
patented dynamic angled panels. All panels exceed ANSI/TIA 568-C.2 and ISO/
IEC 11801 component requirements and Category 6/Class E system performance.  
The Category 6 system from TE complies with all of the performance requirements 
for current and proposed applications such as Gigabit Ethernet (1000BASE-TX), 
10 and 100BASE-TX, token ring, 155 Mbps ATM, 100 Mbps TP-PMD, ISDN, analog 
and digital video and analog and digital voice (VoIP). All panels off er universal 
wiring labels which permit fi eld installation to either T568A or T568B wiring, while 
simplifying ordering and inventorying.   

FEATURES FOR SL PANELS

• 

All panels are packaged unloaded with jacks bagged separately for 
termination with SL series jack termination tool, universal wiring — may be 
terminated to T568A or T568B

• 

12-Port mini patch panels mount vertically on 89D bracket (included)

• 

48-port, 1RU patch panels:

Accommodate adhesive labels or icons for port identifi cation

Are supplied with 48 specially designed SL series jacks (these jacks can 
not be purchased separately – they are supplied with panel assembly only)

• 

Angled panels allow elimination of horizontal cable management for higher 
rack densities and ease of cable dress

• 

Ports may be individually replaced

• 

RoHS Compliant

FEATURES FOR DYNAMIC ANGLE PANELS

• 

 Patented angle right/left eases stress on patch cords allowing for improved 
cable management

• 

 Low profi le dynamic angling allows for greater fl exibility and use in 
cabinet environments

• 

 Conductors can be terminated with either a KRONE or 110 tool

• 

 45 degree silver-plated IDCs provide secure, reliable gas-tight connection

• 

 Includes adhesive paper labels for station identifi cation

• 

 Universal wiring label for easy termination of either T568A/B

• 

 Patch panels are designed to support Gigabit Ethernet transmission speeds

• 

Rear wire manager included

• 

Angled panels allow elimination of horizontal cable management for higher 
rack densities and ease of cable dress

• 

RoHS Compliant

Sc3_Copper_02_6_v1.indd   21

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-22

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

C

OPPER

 

Category 6 Patch Panels

ORDERING INFORMATION

Port 

Count

Footprint

Port Confi guration

Height  (Rack 

Mount Units)

Width

Figure

Part Number

12

89D Bracket

6 pack modules

10.00"

2.30"

A

1375013-2

24

Standard

Discrete SL Jack

1.75" (1RU)

19.00"

1375014-2

6 pack modules

6653 1 679-24

Dynamic Angle

E

PP24AC6T

Angled

Discrete SL Jack

B

1499600-2

48

Standard

Discrete HD Jack*

3.50" (2RU)

19.00"

C

1933458-1*

Angled

1933658-1*

Standard

Discrete SL Jack

D

1375015-2

6 pack modules

6653 1 679-48

Dynamic Angle

PP48AC6T

Angled

Discrete SL Jack

D

1499601-2

96

Standard

Discrete SL Jack

7.00" (4RU)

19.00"

1375016-2

* Note: 1RU 48-port panel does not accept standard SL series jacks

F

igure

 B

F

igure

 C

F

igure

 C

F

igure

 D

F

igure

 D

F

igure

 E

F

igure

 A

Sc3_Copper_02_6_v1.indd   22

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-23

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13  313948AE

C

OPPER

 

FEATURES

• 

Thin profile improves outlet density

• 

Modular Jacks available with integral dust covers

• 

180° or 90° cable dress for easy termination

• 

Universal wiring label permits wiring to T568A or T568B

• 

Meets or exceeds all TIA and ISO component performance requirements

• 

Bend-limiting strain relief included with unshielded jacks

• 

UL Listed: E81956

• 

8-Position RJ45 modular jacks for 1, 2, 3 and 4-pair applications

• 

Can be terminated with either SL series modular jack termination 
tool (1725150-1) or standard 110 punch-down tools

• 

RoHS compliant

• 

Bulk packaging is 25 jacks per bag, 4 bags per carton

• 

Colors in table are approximate

• 

HD Series

 

Specially designed to use with 1RU 48 port SL Patch Panels

 

Bulk packaged 24 per bag

Shielding

Cable Entry

Jack Color

SL Series  
Without 
Dust Cover

SL Series  
With Dust Cover

SL Series  
Without Dust Cover 
Bulk Packaged

HD Series

Unshielded

90° (Side) 

or 

180° (Rear)

Almond

1375055-1

1375187-1

2-1375055-1

Black

1375055-2

1375187-2

2-1375055-2

1499925-2

Gray

1375055-4

1375187-4

2-1375055-4 

Orange

1375055-5

1375187-5

2-1375055-5

Blue

1375055-6

1375187-6

2-1375055-6

1499925-6

Red

1375055-7

1375187-7

2-1375055-7

1499925-7

Yellow

1375055-8

1375187-8

2-1375055-8

1499925-8

Green

1375055-9

1375187-9

2-1375055-9

1499925-9

Violet

1-1375055-0

1-1375187-0

3-1375055-0

Electrical Ivory

1-1375055-1

1-1375187-1

3-1375055-1

Alpine White

1-1375055-3

1-1375187-3

3-1375055-3

1-1499925-3

Shielded

180° (Rear)

Black

1375188-1*

90° (Side)

Black

1479552-1*

* Note:  Shielded jacks are not available in colors, or with dust covers and do not accept strain reliefs. Colors are approximate and for reference only.  

Special HD series jacks used only with 1RU 48-port patch panels. Will not interface with any other panels or faceplates.

ORDERING INFORMATION

Category 6 Modular Jacks and Couplers

TE Connectivity's Category 6 SL series modular jacks exceed ANSI/TIA-568-C.2 
and ISO/IEC 11801 component requirements and Category 6/Class E system 
performance. The AMP NETCONNECT Category 6 system from TE complies with 
all of the performance requirements for current and proposed applications such 
as Gigabit Ethernet (1000BASE-TX), 10 and 100BASE-TX, token ring, 155 Mbps 
ATM, 100 Mbps TP-PMD, ISDN, analog and digital video, and analog and digital 
voice (VoIP). The modular jacks have a slim profile and are compatible with  
SL series and 110Connect faceplates. The universal wiring labels permit 
termination to either T568A or T568B wiring patterns.

Sc3_Copper_02_6_v1.indd   23

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-24

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

C

OPPER

 

SL Series Modular Category 6 Jack Accessories

• 

Compact couplers for two modular plugs

• 

Snaps into 0.585” x 0.790” cut-outs

• 

Wired one-to-one

ORDERING INFORMATION

Description

Part Number

Category 6 SL Coupler

Unshielded

2111123-1

Shielded

2111124-1

Category 6, 8-Position Modular Plug 

• 

Each kit includes:  
– (1) Modular plug assembly 
– (1) Wire holder 
– (1) Strain relief

• 

RoHS compliant

• 

Molded with UL94V-0 plastic

• 

UL Listed: E81956

• 

Category 6 modular plug tooling on page 3-118

• 

Modular plug to die set cross reference on page 3-119

Description 

Conductor

Insulation O.D.

Cable Jacket O.D. 

in (mm)

500 per Box

100 per Box

Unshielded 
or 
Shielded

Solid 

24 – 23 AWG

0.035" to 0.043" 

(0.89 mm to 1.09 mm)

0.20" to 0.24" 

(5.0 mm to 6.0 mm)

5-1375204-2

5-1375204-3

0.035" to 0.043" 

(0.89 mm to 1.09 mm)

0.24" to 0.28" 

(6.0 mm to 7.0 mm)

5-1479185-2

5-1479185-3

Stranded 

26 – 24 AWG

0.035" to 0.043" 

(0.89 mm to 1.09 mm)

0.20" to 0.24" 

(5.0 mm to 6.0 mm)

5-1375202-2

5-1375202-3

0.035" to 0.043" 

(0.89 mm to 1.09 mm)

0.24" to 0.28" 

(6.0 mm to 7.0 mm)

5-1479184-2

5-1479184-3

ORDERING INFORMATION

Sc3_Copper_02_6_v1.indd   24

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-25

www.te.com/EnterpriseNetworks     +1-800-553-0938    Fax: 1-717-986-7406    1/13  313948AE

C

OPPER

 

Description 

Conductor

Insulation O.D.

Cable Jacket O.D.

in (mm)

500 per Box

100 per Box

Unshielded
or
Shielded

Solid

24 – 23 AWG

0.035" to 0.043" 

(0.89 mm to 1.09 mm)

0.20" to 0.24" 

(5.0 mm to 6.0 mm)

5-1375204-2

5-1375204-3

0.035" to 0.043" 

(0.89 mm to 1.09 mm)

0.24" to 0.28" 

(6.0 mm to 7.0 mm)

5-1479185-2

5-1479185-3

Stranded

26 – 24 AWG

0.035" to 0.043" 

(0.89 mm to 1.09 mm)

0.20" to 0.24" 

(5.0 mm to 6.0 mm)

5-1375202-2

5-1375202-3

0.035" to 0.043" 

(0.89 mm to 1.09 mm)

0.24" to 0.28" 

(6.0 mm to 7.0 mm)

5-1479184-2

5-1479184-3

Modular Plug Boots for Category 6 Modular Plugs

• 

For use with Category 6, 8-position modular plugs

• 

Accept cables with diameters as listed

• 

Colors in table are approximate

• 

100 per box

ORDERING INFORMATION

Description

Part Number

Category 6 Copper PVC Patch Cords

T568A wiring

TCPC-6RUVA-XXYYF

T568B wiring

TCPC-6RUVB-XXYYF

Crossover wiring

TCPC-6RUVX-XXYYF

Category 6 Cable Assemblies

An integral part of TE Connectivity’s structured cabling system, these patch
cords are designed to maximize transmission speeds, while reducing crosstalk.

FEATURES

• 

Copper conductors in the cable pairs are stranded for superior fl exibility
and compacted to a near-round shape for optimum signal strength

• 

Exceeds ANSI/TIA 568-C.2 Category 6 performance requirements

• 

Up to 32% smaller outer diameter than other patch cords

• 

Enhanced fl exibility, which notably improves handling and circuit tracing

• 

Clear fl exible strain relief boot maintains proper
bend radius to ensure peak performance

• 

Part of the TE Connectivity 25-year system warranty

ORDERING INFORMATION

Contact TE for additional cable colors and lengths.
Replace YY with: 04=4’, 07=7’, 0=10’, 15=15’, 25=25’, 50=50’ 
Replace XX with: BL=Blue, DB=Dark Blue, WT=White, GY=Gray, RD=Red YL=Yellow, GN=Green

Color

Maximum Cable O.D.

0.24" (6 mm)

Maximum Cable O.D.

0.26" (6.5 mm)

White

9-737893-1

9-336513-1

Gray

9-737893-2

9-336513-2

Red

9-737893-3

9-336513-3

Blue

9-737893-4

9-336513-4

Green

9-737893-5

9-336513-5

Yellow

9-737893-6

9-336513-6

Black

9-737893-7

9-336513-7

Orange

9-737893-8

9-336513-8

Violet

9-737893-9

9-336513-9

Sc3_Copper_02_6_v1.indd   25

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-26

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13  313948AE

C

OPPER

 

Category 6 Termination Blocks 

TE Connectivity’s HighBand and Ultim8 cross connect solutions allow for maximum 
network throughput to support Gigabit Ethernet and support most advanced 
networks. The solution is comprised of high-performance disconnection modules, 
user friendly cable management and innovative anti-snag patch cords. It is the ideal 
cabling solution for companies who require efficiency, guaranteed performance 
and appealing aesthetics. These solutions are based on Patch-by-Exception, which 
is a unique termination technology that offers material, installation and operational 
cost savings, making it a compelling alternative to traditional RJ45 products. TE 
products maintain superior connectivity during hundreds of re-terminations and 
deliver the best electrical performance in the industry.

FEATURES

• 

Features disconnect contacts providing unique patch-by-exception 
functionality and improved administration

• 

Performance exceeds ANSI/TIA 568-C.2 Category 6 

• 

A test port provides “look-both-ways” testing capability without the removal 
of any wires; also allows simple circuit monitoring through use of a test cord

• 

UL certified

Description

Dimensions (HxWxD)

Part Number

8-pair; color-coding for station pairs 
printed on face of block. Includes 
wire guides and jumper rings. 
Three mounting options: snap onto 
universal mounting bracket in Type 
105 position; a Type 105 mounting 
bracket; Type 105 rod mount bracket

0.88" x 4.88" x 1.63" 

(22.5mm x 124mm x 41.4mm)

6468 5 060-06 

Sc3_Copper_02_6_v1.indd   26

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-27

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13  313948AE

C

OPPER

 

Description

Dimensions (HxWxD)

Part Number

300-pair basic system 
Consists of (1) back mount frame, (12) 
25-pair HighBand 25 blocks and (12) 
label holders. Patch cords, optional 
cable troughs, cable management 
rings, covers ordered separately

20.75" x 7.88" x 8.5" 

(528mm x 200mm x 215.9mm)

6450 1 101-10

HighBand 25 block with rear cable 
manager Color-coded; terminates (6) 
4-pair Category 6 cables. Rear cable 
manager simplifies installation; incoming 
cables routed through slots and held 
securely by built-in clips  

Quantity: 12

1.7" x 8.5" x 4.5" 

(43.2mm x 215.9mm x 114.3mm)

6468 5 600-10

HighBand 25 25-pair voice module  
with rear cable manager  

Quantity: 12

1.7" x 8.5" x 4.5" 

(43.2mm x 215.9mm x 114.3mm)

6468 5 300-10

Description

Dimensions (HxWxD)

Part Number

8-pair; color-coding for station pairs 
printed on face of block. Includes 
wire guides and jumper rings. 
Three mounting options: snap onto 
universal mounting bracket in Type 
105 position; a Type 105 mounting 
bracket; Type 105 rod mount bracket

0.88" x 4.88" x 1.63" 

(22.5mm x 124mm x 41.4mm)

6468 5 060-06 

Description

Dimensions (HxWxD)

Part Number

96-pair (24-port) 
Supports field termination of (24) 
4-pair cables. Includes (12) Ultim8 
blocks, (2) horizontal wire managers, 
(1) black or gray universal mounting 
bracket and (1) Type 105 label holder 
with label and protective cover

14.75" x 8.25" x 5.25"  

(374.7mm x 209.6mm x 33.4mm) 

96-pair (24-port) kit; including 
black universal mounting kit

6636 1 596-46 

96-pair (24-port) kit; including 
gray universal mounting kit

6636 1 596-06 

ULTIM8 FIELD ASSEMBLY KIT

QUANTITY: 1

HIGHBAND 25 25-PAIR BLOCK SYSTEMS

ULTIM8 BLOCK   

QUANTITY PER PACK: 10

Adjustable 

Mounting

Bracket 

(in Type 105 

position)

Horizontal 

Wire Managers

Type 105 

Label Holder

8-Pair Block

Type 105 

Label Strip

Category 6 Termination Blocks 

ORDERING INFORMATION

HighBand 25 block 

with rear cable manager

HighBand 25 label holder 

shown mounted on block

HighBand 25  

back mount frame

Sc3_Copper_02_6_v1.indd   27

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-28

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13  313948AE

C

OPPER

 

Patch Cords for Ultim8 Blocks

These patch cords allow direct patching 
capability between Ultim8 blocks or patching 
from an Ultim8 block to an active device or an 
RJ45 patch panel.

®

Ultim8 to Ultim8 patch cord

Ultim8 to RJ45 patch cord

Description

Cable Color

Catalog Number

Ultim8 plug to Ultim8 plug,

  

wired straight through; wired top (cable) side only
Quantity: 1

White 

TP6TH-WTXX

Blue 

TP6TH-BLXX

Red 

TP6TH-RDXX

Green 

TP6TH-GNXX

Yellow 

TP6TH-YLXX

Gray 

TP6TH-GYXX

Ultim8 plug to RJ45 plug, T568A

 

Quantity: 1

White 

TP6TB0WTXX

Blue 

TP6TB0BLXX

Red 

TP6TB0RDXX

Green 

TP6TB0GNXX

Yellow 

TP6TB0YLXX

Gray 

TP6TB0GYXX

Ultim8 plug to RJ45 plug, T568B

 

Quantity: 1

White 

TP6TB-WTXX

Blue 

TP6TB-BLXX

Red 

TP6TB-RDXX

Green 

TP6TB-GNXX

Yellow 

TP6TB-YLXX

Gray 

TP6TB-GYXX

* Replace XX with: 

04 = 4' 
07 = 7' 
10 = 10' 
15 = 15' 
25 = 25' 
50 = 50'

Contact TE for additional cable colors and lengths.

Pair No.

Pair 4

Pair 3

Pair 2

Pair 1

R

T

R

T

R

T

R

T

Pair No.

Pair 4

Pair 3

Pair 2

Pair 1

RJ45 Plug 

Pin #

8

7

2

1

6

3

4

5

R

T

R

T

R

T

R

T

Pair No.

Pair 4

Pair 3

Pair 2

Pair 1

RJ45 Plug 

Pin #

8

7

6

3

2

1

4

5

R

T

R

T

R

T

R

T

ORDERING INFORMATION

Sc3_Copper_02_6_v1.indd   28

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-29

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13  313948AE

C

OPPER

 

Description

Catalog Number

Ultim8 plug to Ultim8 plug,  

1-pair, wired top (cable) side only, white cable 

Quantity: 1

 

6648 2 000-XX

Ultim8 plug to Ultim8 plug,  

2-pair, wired top (cable) side only, white cable 

Quantity: 1

6648 2 005-XX

* Replace XX with: 

04 = 4' 
07 = 7' 
10 = 10' 
15 = 15' 
25 = 25' 
50 = 50'

Ultim8 2-pair patch cord

Ultim8 1- and 2-Pair Patch Cords

These patch cords provide direct patching capability using standard 
straight-through wiring. Ultim8 block plugs are keyed for proper 
insertion and have a latching mechanism to keep them secure. These 
patch cords are recommended for 10Base-T/Token Ring or voice 
installations using Ultim8 blocks..

ORDERING INFORMATION

Pair No.

Pair 1

R

T

K

RO

N

E

K

RO

N

E

Pair No.

Pair 2

Pair 1

R

T

R

T

Sc3_Copper_02_6_v1.indd   29

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-30

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13  313948AE

C

OPPER

 

HighBand Patch Cords

The HighBand patch cords are Category 6 and 6A compliant and come in 
a number of styles to suit the various applications. The 4-pair rear facing 
patch cord is ideally suited to the 12-way and 36-way configurations.

The 1-pair patch cord is available for patching voice 1-pair to 1-pair or can 
also be utilised for single pair testing.

The front facing patch cords are ideal in rack mount installations or when 
patching is commonplace.

4-pair Front Facing

1-pair Rear Facing

4-pair Rear Facing

Sc3_Copper_02_6_v1.indd   30

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Category 6 Products

3-31

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13  313948AE

C

OPPER

 

Description

Quantity

Length

Color

Product Number

HighBand Category 6A Patch Cords

4-pair Rear Facing Patch Cord 

Bag of 1

1.2m 

Blue

6451 2 401C-10

4-pair Rear Facing Patch Cord 

Bag of 1

2.1m 

Blue

6451 2 401C-20

4-pair Rear Facing Patch Cord 

Bag of 1

3.0m 

Blue

6451 2 401C-30

4-pair Rear Facing Patch Cord 

Bag of 1

4.5m 

Blue

6451 2 401C-40

4-pair Front Facing Patch Cord 

Bag of 1

1.2m 

Blue

6451 2 403C-10

4-pair Front Facing Patch Cord 

Bag of 1

2.1m 

Blue

6451 2 403C-20

4-pair Front Facing Patch Cord 

Bag of 1

3.0m 

Blue

6451 2 403C-30

4-pair Front Facing Patch Cord 

Bag of 1

4.5m 

Blue

6451 2 403C-40

4-pair Rear Facing to RJ45 Patch Cord 

Bag of 1

1.2m 

Blue

6451 2 400C-10

4-pair Rear Facing To RJ45 Patch Cord 

Bag of 1

2.1m 

Blue

6451 2 400C-20

4-pair Rear Facing To RJ45 Patch Cord 

Bag of 1

3.0m 

Blue

6451 2 400C-30

4-pair Rear Facing To RJ45 Patch Cord 

Bag of 1

4.5m 

Blue

6451 2 400C-40

4-pair Front Facing to RJ45 Patch Cord 

Bag of 1

1.2m 

Blue

6451 2 404C-10

4-pair Front Facing To RJ45 Patch Cord 

Bag of 1

2.1m 

Blue

6451 2 404C-20

4-pair Front Facing To RJ45 Patch Cord 

Bag of 1

3.0m 

Blue

6451 2 404C-30

4-pair Front Facing To RJ45 Patch Cord 

Bag of 1

4.5m 

Blue

6451 2 404C-40

HighBand Category 6 Patch Cords

4-pair to 4-pair Rear

Bag of 1

1.2m

Blue

6451 2 701C-10

4-pair to 4-pair Rear

Bag of 1

2.1m

Blue

6451 2 701C-20

4-pair to 4-pair Rear

Bag of 1

3.0m

Blue

6451 2 701C-30

4-pair to 4-pair Rear

Bag of 1

4.5m

Blue

6451 2 701C-40

4-pair to RJ45 Rear

Bag of 1

1.2m

Blue

6451 2 700C-10

4-pair to RJ45 Rear

Bag of 1

2.1m

Blue

6451 2 700C-20

4-pair to RJ45 Rear

Bag of 1

3.0m

Blue

6451 2 700C-30

4-pair to RJ45 Rear

Bag of 1

4.5m

Blue

6451 2 700C-40

1-pair to 1-pair Rear

Bag of 1

1.2m

White

6451 2 702-10

1-pair to 1-pair Rear

Bag of 1

2.1m

White

6451 2 702-20

1-pair to 1-pair Rear

Bag of 1

3.0m

White

6451 2 702-30

1-pair to 1-pair Rear

Bag of 1

4.5m

White

6451 2 702-40

4-pair to 4-pair Front

Bag of 1

1.2m

Blue

6451 2 703C-10

4-pair to 4-pair Front

Bag of 1

2.1m

Blue

6451 2 703C-20

4-pair to 4-pair Front

Bag of 1

3.0m

Blue

6451 2 703C-30

4-pair to 4-pair Front

Bag of 1

4.5m

Blue

6451 2 703C-40

4-pair to RJ45 Front

Bag of 1

1.2m

Blue

6451 2 704C-10

4-pair to RJ45 Front

Bag of 1

2.1m

Blue

6451 2 704C-20

4-pair to RJ45 Front

Bag of 1

3.0m

Blue

6451 2 704C-30

4-pair to RJ45 Front

Bag of 1

4.5m

Blue

6451 2 704C-40

ORDERING INFORMATION

Sc3_Copper_02_6_v1.indd   31

12/7/12   12:06 PM

Tyco-catalog-AMP-2013-html.html
background image

3-32

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

Category 5e Twisted Pair Cable

TE Connectivity off ers a wide variety of Category 5e cable. The 5e portfolio 
includes UTP, F/UTP, as well as Outback outdoor cable. All TE cables are 
produced by highly automated manufacturing processes that ensure consistent 
quality and dependability with superior electrical perfromance. All TE cables 
are independently verifi ed to ANSI/TIA 568-C.2.

520 Series, Category 5e UTP Cable

FEATURES

• 

AirES patented design on CMP for higher throughput and reduced size.

• 

Performance characterized to 350 MHz

• 

   7 dB NEXT performance above Category 5e

• 

Meets or exceeds  ANSI/TIA-568-C.2 Enhanced Category 
5 and ISO Class D 11801:2002 specifi cations

• 

Independently verifi ed by Intertek ETL SEMKO testing services

• 

RoHS compliant

• 

24 AWG, solid conductors

• 

Available in side-by-side confi guration

UL/NEC Ratings

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Part Number

CMP

4 Pair

1000' Reel in box

0.174"

24

23

TE520P-XXRB

1000' Pull box

20

TE520P-XXII

1000' Reel

20

TE520P-XX02

4 Pair Side-by-Side 1000' Reel 

.174"x.360"

24

48

TE520PX2-XX02

CMR

4 Pair

1000' Reel in box

0.185"

24

25

TE520R-XXRB

1000' Pull box

21

TE520R-XXII

1000' Reel

21

TE520R-XX02

4 Pair Side-by-Side 1000' Reel 

.185"x.380"

24

50

TE520RX2-XX02

ORDERING INFORMATION

The following jacket colors are available. Replace "XX" with
BL-Blue 

WT-White 

GY-Gray 

YL-Yellow 

GN-Green 

BK-Black 

RD-Red 

OR-Orange 

VT-Violet 

BN-Brown

Additional reel sizes available, please contact TE Customer Service.

Sc3_Copper_03_5e_v1.indd   32

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-33

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

ORDERING INFORMATION

520 Series, Category 5e F/UTP Cable 

FEATURES

• 

F/UTP design with foil shield for outstanding signal isolation 

• 

Meets or exceeds ANSI/TIA-568-C.2 Enhanced Category 
5 and ISO 11801: 2002 Class D specifi cations

• 

Exceeds all requirements for Gigabit Ethernet

• 

24 AWG, solid conductors

• 

RoHS compliant

UL/NEC Ratings

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Part Number

CMP

4

1000' Reel

0.252"

24

36

TE520PF-XX02

CMR

4

1000' Reel

0.250"

24

34

TE520RF-XX02

The following jacket colors are available, replace XX with:
BL-Blue 

WT-White

GY-Gray 

YL-Yellow

 

Sc3_Copper_03_5e_v1.indd   33

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-34

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

Additional reel sizes available, please contact TE Customer Service.

ORDERING INFORMATION

Outback 520 Outdoor Series, Outdoor Category 5e UTP Cable

FEATURES

• 

4-pair, 24 awg Category 5e cable designed for outdoor use 

• 

Excellent transmission and weather resistant properties 

• 

Polyethylene jacket for weather resistance

• 

Performance characterized to 350MHz

• 

Meets or exceeds all requirements for Gigabit Ethernet 

• 

Not intended for wet applications

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Part Number

Color

4

Reel in box

0.210"

24

23

TE5200SP-BKRB

Black

4

Reel

0.210"

24

20

TE5200SP-BK02

Sc3_Copper_03_5e_v1.indd   34

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-35

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Part Number

Color

4

Reel in box

0.210"

24

23

TE5200SP-BKRB

Black

4

Reel

0.210"

24

20

TE5200SP-BK02

UL/NEC Ratings

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Part Number

CMP

4

1000' Pull box

0.182"

24

20

TE510P-XXII

1000' Reel

TE510P-XX02

CMR

4

1000' Pull box

0.185"

24

20

TE510R-XXII

1000' Reel

TE510R-XX02

ORDERING INFORMATION

510 Series, Category 5e UTP Cable 

FEATURES

• 

Independently verifi ed by Intertek ETL SEMKO testing services

• 

Meets or exceeds  ANSI/TIA-568-C.2 Enhanced Category 
5 and ISO 11801: 2002 Class D specifi cations

• 

24 AWG, solid conductors

• 

RoHS compliant

• 

Performance characterized to 100 MHz

• 

Meets or exceeds all requirements for Gigabit Ethernet

The following jacket colors are available. Replace "XX" with
BL-Blue 

WT-White 

GY-Gray 

YL-Yellow 

GN-Green 

BK-Black 

RD-Red 

OR-Orange  

VT-Violet 

BN-Brown

Additional reel sizes available, please contact TE Customer Service.

UL/NEC Ratings

Pair Count

Package

OD (in)

AWG

Weight lbs/Kft

Part Number

CMP

25

1000' Reel

0.460"

24

142

TE510P25-XX02

CMR

25

1000' Reel

0.510"

24

130

TE510R25-XX02

Jacket

Conductor

Insulation

Filler

Cat5e

25 Pair

The following jacket colors are available, replace XX with:
BL-Blue 

WT-White

GY-Gray 

4 Pair

Sc3_Copper_03_5e_v1.indd   35

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-36

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

Note:  Unless otherwise specifi ed, all lengths are 1000 feet (305 meters). Other lengths and colors available. 

Category

Condition

Riser/Plenum

Cat 5e

Storage

 -4 – 176° F (-20 – 80° C)

Operating

 -4 – 140° F (-20 – 60° C)

Installation

 41 – 122° F (5 – 50° C)

Ring Conductor

Tip Conductor

Twisted Pair

Pair

Jacket Color

1

Tip

 White

Ring

 Blue

2

Tip

White

Ring

Orange

3

Tip

White

Ring

Green

4

Tip

White

Ring

Brown

Twisted Pair Cable Packaging Reference

II = Pull Box

RB = Reel-in-a-Box

4-PAIR CONDUCTOR COLOR CODE

TWISTED PAIR CABLE TEMPERATURES

02 = Reel

Sc3_Copper_03_5e_v1.indd   36

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-37

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

Color Group

Pair

Conductor Jacket Color

White (1)

1

Tip

White

Ring

Blue

2

Tip

White

Ring

Orange

3

Tip

White

Ring

Green

4

Tip

White

Ring

Brown

5

Tip

White

Ring

Slate

Red (2)

6

Tip

Red

Ring

Blue

7

Tip

Red

Ring

Orange

8

Tip

Red

Ring

Green

9

Tip

Red

Ring

Brown

10

Tip

Red

Ring

Slate

Black (3)

11

Tip

Black

Ring

Blue

12

Tip

Black

Ring

Orange

13

Tip

Black

Ring

Green

14

Tip

Black

Ring

Brown

15

Tip

Black

Ring

Slate

Yellow (4)

16

Tip

Yellow

Ring

Blue

17

Tip

Yellow

Ring

Orange

18

Tip

Yellow

Ring

Green

19

Tip

Yellow

Ring

Brown

20

Tip

Yellow

Ring

Slate

Violet (5)

21

Tip

Violet

Ring

Blue

22

Tip

Violet

Ring

Orange

23

Tip

Violet

Ring

Green

24

Tip

Violet

Ring

Brown

25

Tip

Violet

Ring

Slate

25-Pair Conductor Color Code

Sc3_Copper_03_5e_v1.indd   37

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-38

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

Category 5e Patch Panels 

TE Connectivity's patch panels are offered in several different styles and port 
configurations. This includes standard flat panels, fixed angled panels and TE's 
patented dynamic angled panels. All panels exceed Enhanced Category 5 
ANSI/TIA-568-C.2 and Category 5 ISO/IEC 11801 component requirements and  
Enhanced Category 5/Class D system performance. The Enhanced Category 5 
System from TE complies with all of the performance requirements for current 
and proposed applications such as Gigabit Ethernet (1000BASE-TX), 10 and 
100BASE-Tx, token ring, 155 Mbps ATM, 100 Mbps TP-PMD, ISDN, analog and 
digital video, and analog and digital voice (VoIP). Panels can be rack mounted 
in standard EIA 19-inch racks or wall mounted using optional 19-inch hinged wall 
mount brackets.

FEATURES FOR SL SERIES AND 110CONNECT PANELS

• 

Meet or exceed TIA and ISO Category 5e/Class D component performance 
requirements

• 

Universal wiring – ports may be terminated to T568A or T568B

• 

110Connect termination patch panels may be terminated using single-wire 
110 impact tool, KRONE tool, or 5-pair tool

• 

Angled and integrated cable managment panels allow the elimination of 
horizontal cable management for higher rack densities and ease of 
cable dress

• 

12-port mini patch panels mount vertically on included 89D bracket

• 

SL Series termination patch panels:

Feature individually replaceable ports

Are packaged unloaded with jacks bagged separately for termination 
with SL Series jack termination tool

• 

48-port 1RU patch panels:

Accommodate adhesive labels or icons for port identification

Are supplied with 48 specially developed jacks, bagged separately for 
termination with SL series jack termination tool (Jacks supplied with 
panel assembly only; they can not be purchased separately.)

• 

UL1863 Listed  

• 

RoHS compliant

FEATURES FOR DYNAMIC ANGLED PANELS

• 

Patented angle right/left eases stress on patch cords allowing for improved cable management

• 

Low profile dynamic angling allows for greater flexibility and use in cabinet environments

• 

Conductors can be terminated with either a KRONE or 110 tool

• 

45 degree silver-plated IDCs provide secure, reliable gas-tight connection

• 

Includes adhesive paper labels for station identification

• 

Universal wiring label for easy termination of either T568A/B

• 

Patch panels are designed to support Gigabit Ethernet transmission speeds

• 

Rear Wire Manager included

• 

TrueNet ID Tab adapter bezel included for use with TrueNet ID Tabs

• 

UL1863 Listed  

• 

RoHS compliant

Back Detail

SL Series Panels

Front Detail

Back Detail

110Connect Panels

Front Detail

Dyamic Angled Panels

Sc3_Copper_03_5e_v1.indd   38

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-39

Copper

Category 5e Products

C

OPPER

 

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Port Count

Footprint

Port Configuration

Height

(Rack Mount Units)

Width

Figure

Part Number

12

89D Bracket

Discrete SL Jack

10.00"

2.30"

A

1479153-2

6 pack modules

B

406390-1

Standard

1.75" (1RU)

19.00"

-

406981-1

24

Standard

Discrete SL Jack

1.75" (1RU)

19.00"

-

1479154-2

6 pack modules

-

406330-1

Dynamic Angle

J

PP24AC5ET

Integrated Cable Management

D

1479206-1

Angled

Discrete SL Jack

C

1499602-2

48

Standard

Discrete HD Jack*

3.50" (2RU)

19.00"

E

1933457-1*

Angled

H

1933657-1*

Standard

Discrete SL Jack

F

1479155-2

6 pack modules

G

406331-1

Dynamic Angle

-

PP48AC5ET

Angled

Discrete SL Jack

I

1499603-2

96

Standard

Discrete SL Jack

7.00" (4RU)

19.00"

-

1479156-2

6 pack modules

-

406332-1

Figure F - Standard

Figure E - Standard

Figure G - Standard

Figure H - Angled

Figure D - Integrated Cable 

Management

Figure C - Angled

Figure I - Angled

ORDERING INFORMATION

Figure A

Figure B

Figure J - 

Dynamic Angled

 

*Note: 1RU 48-port panel does not accept standard SL Series jacks

Sc3_Copper_03_5e_v1.indd   39

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-40

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

Category 5e Modular Jacks and Couplers
 

TE Connectivity's Category 5E SL Series Modular Jacks exceed Enhanced Category 
5 ANSI/TIA-568-C.2 and Category 5 ISO/IEC 11801 component requirements and 
Enhanced Category 5/Class D system performance. The AMP NETCONNECT 
Enhanced Category 5 System from TE complies with all of the performance 
requirements for current and proposed applications such as Gigabit Ethernet 
(1000BASE-TX), 10 and 100BASE-Tx, token ring, 155 Mbps ATM, 100 Mbps TP-PMD, 
ISDN, analog and digital video, and analog and digital voice (VoIP).

SL Series Category 5e Modular Jacks 
 

FEATURES

• 

Thin profile improves outlet density

• 

Modular jacks available with integral dust covers

• 

180° or 90° cable dress for easy termination

• 

Universal wiring label permits wiring toT568A or T568B

• 

Meets or exceeds all TIA and ISO component performance requirements

• 

Bend-limiting strain relief included with unshielded jacks

• 

UL Listed: E81956

• 

8-Position RJ45 modular jacks for 1, 2, 3 and 4-pair applications

• 

Can be terminated with either SL series modular jack termination tool 
(1725150-1) or standard 110 punch-down tools

• 

RoHS compliant

• 

The bulk option is 25 jacks per bag, 4 bags per carton

• 

HD Series

Specially designed to use with 1RU 48 port SL Patch Panels

Bulk packaged 24 per bag

Sc3_Copper_03_5e_v1.indd   40

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-41

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

SL Series Modular Coupler
 

FEATURES

• 

Compact couplers for two modular plugs

• 

Snaps into 0.585” x 0.790” cut-outs

• 

Wired one-to-one

ORDERING INFORMATION

Description

Shielding

Part Number

Category 5e SL Coupler

Unshielded

2111121-1

Shielded

2111122-1

Category 5e SL

Unshielded Coupler

ORDERING INFORMATION

Shielding

Cable Entry

SL Series  

Jack Color

SL Series  
Without Dust Cover With Dust Cover

SL Series  
Without Dust Cover  
Bulk Packaged

HD Series

*

Unshielded

90° (Side) or 

180° (Rear)

Almond

1375191-1

1375190-1

2-1375191-1

Black

1375191-2

1375190-2

2-1375191-2

1933455-2

Gray

1375191-4

1375190-4

2-1375191-4

Orange

1375191-5

1375190-5

2-1375191-5

Blue

1375191-6

1375190-6

2-1375191-6

1933455-6

Red

1375191-7

1375190-7

2-1375191-7

1933455-7

Yellow

1375191-8

1375190-8

2-1375191-8

1933455-8

Green

1375191-9

1375190-9

2-1375191-9

1933455-9

Violet

1-1375191-0

1-1375190-0

3-1375191-0

Electrical Ivory

1-1375191-1

1-1375190-1

3-1375191-1

Alpine White

1-1375191-3

1-1375190-3

3-1375191-3

1-1933455-3

Shielded

180° (Rear)

Black

1375189-1*

90° (Side)

Black

1479717-1*

* Note: Shielded jacks are not available in colors, or with dust covers and do not accept strain reliefs. Colors are approximate and for reference only.
 

Special HD series jacks used only with 1RU 48-port patch panels. Will not interface with any other panels or faceplates.

Sc3_Copper_03_5e_v1.indd   41

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-42

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

ORDERING INFORMATION

Description

AWG

Insulation O.D.

Cable Jacket O.D.

Conductor

Part Number

500 per box

100 per box

Unshielded

24

  0.039" (0.99 mm)

0.190" to 0.220" 

(4.83 mm to 5.59 mm)

Stranded

5-558530-2

5-558530-3

28 – 24

0.035" to 0.039"  

(0.89 mm to 0.99 mm)

0.190" to 0.200"  

(4.83 mm to 5.08 mm)

Solid

5-569278-2

5-569278-3

Shielded

26 – 24

0.035" to 0.039"  

(0.89 mm to 0.99 mm)

0.190" to 0.200"  

(4.83 mm to 5.08 mm)

Stranded

5-569552-2

5-569552-3

Solid

5-569550-2

5-569550-3

      

Category 5e Modular Plugs

FEATURES

• 

Meets TIA and ISO requirements for component performance

• 

Modular plug tooling will be referenced in tooling section

• 

Each kit includes:

Plug housing

Load bar

• 

Load bar helps maintain pair twist

• 

RoHS compliant

• 

Molded with UL94V-0 Plastic

• 

UL Listed: E81956

• 

Modular plug to die set cross reference will be referenced in 
tooling section 3-120

Sc3_Copper_03_5e_v1.indd   42

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-43

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

Description

AWG

Insulation O.D.

Cable Jacket O.D.

Conductor

Part Number

500 per box

100 per box

Unshielded

24

  0.039" (0.99 mm)

0.190" to 0.220" 

(4.83 mm to 5.59 mm)

Stranded

5-558530-2

5-558530-3

28 – 24

0.035" to 0.039"  

(0.89 mm to 0.99 mm)

0.190" to 0.200"  

(4.83 mm to 5.08 mm)

Solid

5-569278-2

5-569278-3

Shielded

26 – 24

0.035" to 0.039"  

(0.89 mm to 0.99 mm)

0.190" to 0.200"  

(4.83 mm to 5.08 mm)

Stranded

5-569552-2

5-569552-3

Solid

5-569550-2

5-569550-3

      

ORDERING INFORMATION

Modular Plug Boots

FEATURES

• 

For use with Category 3, 5 and 5e 8-position modular plugs

• 

Accept cables with a maximum diameter of 0.210" (5.33 mm)

• 

1000 boots per box

 Description

Maximum Cable Diameter

Color

Part Number

Modular Plug Boots

0.210" (5.33 mm)

Black

569875-1

Almond

569875-2

Red

569875-3

Green

569875-4

Blue

569875-5

Yellow

569875-6

Orange

569875-7

White

569875-8

Violet

569875-9

Gray

1-569875-0

Slimline Modular Plug Boots

0.220" (5.59 mm)

Clear

2111399-1

NOTE: Colors are approximate and for reference only.

ORDERING INFORMATION

External Strain Reliefs For Modular Plugs

FEATURES

• 

Metal strain relief that positively engages plug housing

• 

PRO-CRIMPER Tool and Die Set reference will be noted in tooling section

• 

For use with 8-position Category 3, 5 and 5e Modular Plugs only

• 

RoHS compliant

Description

Part Number

Not for use with Modular Plug Boots

558527-1

For use with Modular Plug Boots

558527-3

Clear Slimline

Modular Plug Boot

Sc3_Copper_03_5e_v1.indd   43

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-44

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

Bootless, Unshielded

Category 5e Cable Assemblies

An integral part of TE Connectivity’s structured cabling system, these patch cords
are designed to maximize transmission speeds, while reducing crosstalk.

FEATURES

• 

Copper conductors in the cable pairs are stranded for superior fl exibility
and compacted to a near-round shape for optimum signal strength

• 

Exceeds ANSI/TIA Category 5e performance requirements

• 

Up to 28% smaller outer diameter than other patch cords

• 

Enhanced fl exibility, which notably improves handling and circuit tracing

• 

Slimline design displays clear fl exible strain relief boot maintains
proper bend radius to ensure peak performance

• 

Part of the TE Connectivity 25-year system warranty

ORDERING INFORMATION

Description

Part Number

Category 5e Copper PVC Patch Cords

T568A wiring Slimline

TCPC-5ERUVA-XXYYF

T568B wiring Slimline

TCPC-5ERUVB-XXYYF

Crossover wiring Slimline

TCPC-5ERUVX-XXYYF

T568A wiring Bootless

TCPC-5ENUVA-XXYYF

Contact TE for additional cable colors and lengths.

Replace XX with: 
BL=Blue  

DB=Dark Blue  

WT=White  

RD=Red  

YL=Yellow  

GN=Green

 

 

 

 

GY=Gray

Replace YY with: 
04=4’  

07=7’  

10=10’

15=15’  

25=25’  

50=50’

SPECIFICATIONS

Operating Temperature Range:

-40° to 70° C (-40° to 158° F)

RJ45 Plug Interface According to:

 

IEC 60603-7

Transmission Performance and Reliability:

 ANSI/TIA-568-C.2 Category 5e

 ISO 11801 Class D Standard

Number of Plug Insertion Cycles:

 

 750 (IEC/EN 60603-7)

Conductor:

24 AWG 7X32 stranded tinned copper

Jacket:

Lead free PVC

Nominal Outer Diameter:

5.3 mm ± .13 mm (0.210" ± .005")

Safety Listing:

UL 1863

Flammability Rating:

UL 94V-0

Slimline Cable Assemblies

Sc3_Copper_03_5e_v1.indd   44

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-45

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

Category 5e Termination Blocks

TE Connectivity’s AMP NETCONNECT 110CONNECT XC Cross Connect products 
exceed Enhanced Category 5 TIA/EIA-568-C.2 performance. The system complies 
with all of the performance requirements for current and proposed applications such 
as 100BASE-Tx, 155 Mbps ATM and Gigabit Ethernet. The 110Connect punchdown 
wiringbocks are terminated from the horizontal station fi eld utilizing 110 single or 
5-pair wire tools. Connecting blocks utilizing double-ended IDC contacts are then 
seated in place connecting to the equipment fi eld.

Connector

Part Number

End A

End B

Pair Count

Wiring

2' (0.61 m)

4' (1.22 m)

6' (1.83 m)

8' (2.44 m)

10' (3.05 m)

110Connect XC

110Connect XC

1

569523-2

569523-4

569523-6

569523-8

1-569523-0

2

569524-2

569524-4

569524-6

569524-8

1-569524-0

4

569526-2

569526-4

569526-6

569526-8

1-569526-0

RJ45

4

T568A

569527-2

569527-4

569527-6

569527-8

1-569527-0

4

T568B

569528-2

569528-4

569528-6

569528-8

1-569528-0

2

T568A, 10/100BASE-T 569685-2

569685-4

569685-6

569685-8

1-569685-0

2

T568B, 10/100BASE-T 569669-2

569669-4

569669-6

569669-8

1-569669-0

110Connect XC Category 5e Cable Assemblies 

FEATURES

• 

Meets or exceeds Category 5e performance requirements

• 

4-Pair stranded unshielded 24 AWG conductors

• 

Modular RJ45 plugs feature color-matched snagless boots

• 

110Connect XC to RJ45 patch cable assemblies must be 
selected to match wiring pattern of work area outlet wiring

• 

Non-plenum (CM rated)

• 

Universal wiring (T568A/T568B)

• 

RoHS compliant

RJ45 Plug

110Connect XC Plug

ORDERING INFORMATION

Sc3_Copper_03_5e_v1.indd   45

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-46

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

100 Pair with legs

100 Pair without legs

110Connect XC Category 5e Wiring Blocks
 

FEATURES

• 

Accepts 24-22 AWG conductor

• 

Blocks are available in 50, 100 and 300-pair sizes with legs for blackboard mounting

• 

Supports applications from voice to high-speed data

• 

Offers a reliable and economical high-density system

• 

Meets or exceeds the TIA specifications for Category 5e

• 

All components compatible with TE’s industry standard AMP NETCONNECT
impact tools, the KRONE tool and the 788J1 5-pair tool

• 

UL listed

• 

CSA and Austel approved

Description

Legs

Pair Count

Part Number

Wiring Blocks

With

50

558841-1

100

558842-1

300

558843-1

Without

50

558839-1

100

558840-1

ORDERING INFORMATION

4 Pair

5 Pair

110Connect XC Category 5e Connecting Blocks
 

FEATURES

• 

Utilize double-ended insulation displacement contacts (IDC) that terminate
24-22 AWG solid or stranded conductors with a maximum O.D. of .063 inch

• 

Available in 4- and 5-pair sizes with the appropriate color coding

• 

Supports applications from voice to high-speed data

• 

Meets or exceeds the TIA specifications for Category 5e

• 

All components compatible with TE's industry standard AMP
NETCONNECT impact tools, the KRONE tool and the 788J1 5-pair tool

• 

UL listed

• 

CSA and Austel approved

Description

Pair Count

Part Number

Connecting Blocks

4

558401-1

5

558402-1

ORDERING INFORMATION

Sc3_Copper_03_5e_v1.indd   46

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-47

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

Description

Legs

Pair Count

Part Number

Wiring Blocks

With

50

558841-1

100

558842-1

300

558843-1

Without

50

558839-1

100

558840-1

Adapter for 89B Bracket
 

FEATURES

• 

Used to mount a 50-pair 110Connect XC wiring block on a 89B bracket

• 

Two adapters are required for each assembly

• 

Wiring blocks and 89B brackets purchased separately

Description

Part Number

Adapter for 89B Bracket

558838-1

ORDERING INFORMATION

110Connect XC Category 5e Kits
 

FEATURES

• 

Kits include wiring blocks with legs, connecting blocks, designation
strips and white labels for the pair counts identified

• 

Supports applications from voice to high-speed data

• 

Offers a reliable and economical high-density system

• 

Meets or exceeds the TIA specifications for Category 5e

• 

All components compatible with TE’s industry standard AMP
NETCONNECT impact tools, the KRONE tool and the 788J1 5-pair tool

• 

UL listed

• 

CSA and Austel approved

Pair Count

Included 4-Pair Connecting Blocks Included 5-Pair Connecting Blocks

Part Number

50

10

2

569433-1

0

10

569434-1

100

20

4

569439-1

0

20

569440-1

300

60

12

569445-1

0

60

569446-1

ORDERING INFORMATION

Sc3_Copper_03_5e_v1.indd   47

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-48

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

110Connect XC Category 5e Cross-Connect Distribution Frame Kits
 

FEATURES

• 

Reduce time needed for planning and installing a cross-connect on a backboard

• 

Includes metal back frame, wiring blocks, connecting blocks, cable management
troughs, designation strips and appropriate hardware

• 

Quick and easy installation

• 

Available in 300 and 900-pair sizes with 4 and 5-pair connecting blocks

• 

Supports applications from voice to high-speed data

• 

Offers a reliable and economical high-density system

• 

Meets or exceeds the TIA specifications for Category 5e

• 

All components compatible with TE ’s industry standard AMP NETCONNECT
impact tools, the KRONE tool and the 788J1 5-pair tool

• 

UL listed

• 

CSA and Austel approved

ORDERING INFORMATION

Pair Count

Included 4-Pair Connecting Blocks Included 5-Pair Connecting Blocks

Part Number

300

60

12

569854-1

0

60

569855-1

900

120

24

569857-1

0

120

569858-1

Sc3_Copper_03_5e_v1.indd   48

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-49

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

ORDERING INFORMATION

Description

Color

Option

Part Number

Cable Management Trough

White

With Legs

569389-1

Without Legs

569597-1

Vertical Cable Management Frame

White

300-Pair

569851-1

900-Pair

569852-1

Cable Management Rings

Black

5.7” W

569431-1

8.5” W

569599-1

110Connect XC Cable Management  
 

FEATURES

• 

Cable management frames and cable management rings provide high 
capacity storage of patch cables and jumper wire

• 

   Cable Management Trough provides horizontal management and 
organization of patch cables and jumper wire

• 

Troughs are available with or without legs

• 

Suitable for mounting directly to a plywood backboard

• 

   Quick and easy installation

Cable Management 

Trough with legs

Vertical Cable 

Management Frame

Cable Management 

Ring

Sc3_Copper_03_5e_v1.indd   49

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-50

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Copper

Category 5e Products

C

OPPER

 

110Connect XC Category 5e Cross-Connect Rack Mount Panel 
 

FEATURES

 

• 

For mounting cross-connect hardware on  a 19-inch rack

• 

Wiring block and cable management panels available

• 

  Labels available

• 

Connecting blocks and plastic label covers purchased separately

• 

Rack mount cable management panels provide horizontal management and 
organization of patch cables and jumper wire

• 

Supports applications from voice to high-speed data

• 

Offers a reliable and economical high-density system

• 

Meets or exceeds the TIA specifications for Category 5e

• 

All components compatible with TE’s industry standard AMP NETCONNECT 
impact tools, the KRONE tool and the 788J1 5-pair tool

• 

  UL listed

• 

  CSA and Austel approved

Description

Pair Count

Height

Width

Part Number

Rack Mount Panel Kits

110Connect XC Cross-Connect

100

1RU (1.75")

19"

558635-1

200

2RU (3.50")

19"

558637-1

400

5RU (8.75")

19"

558639-1

Cable Management Trough

2RU (3.50")

19"

406641-1

ORDERING INFORMATION

Cable Management Trough

200 Pair 110Connect XC 

Cross-Connect

Sc3_Copper_03_5e_v1.indd   50

12/7/12   1:51 PM

Tyco-catalog-AMP-2013-html.html
background image

3-51

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Trunk Solutions – MRJ21

MRJ21 Copper Cabling Solutions

MRJ21 is a high-density, small form factor modular system that provides space 
and time saving benefits in today's data center environment. The pluggable 
design satisfies the current 10/100/1000 BASE-T requirements as well as future 
10 GbE system applications. The cable assemblies are factory terminated, 100% 
tested and serialized.

More information on the MRJ21 solution can be found at www.te.com/MRJ21.

 
FEATURES

• 

Dense RJ21 style double blade design with offset jackscrews

• 

Contact layout and footprint for differential pairs creates reduced 
crosstalk and built-in compensation

• 

1.5 to 4 times the port density of 2x6 stacked modular jack (RJ45)

• 

3 times the port density of an RJ21 connector

• 

Jackscrews for positive latching and secure cable retention

• 

Robust die cast cable covers provide 45° left or right cable exit for ease 
of routing

• 

1 mm pair spacing, 1.5 mm pair-to-pair spacing  

• 

Reduced cable bulk allows better air circulation and equipment cooling in 
data centers

• 

Approximately 30% less area and 20% less weight than 4-pair cabling

• 

Enables 25% less power per port than 4-pair connector on 
active electronics

• 

Pre-terminated cable assemblies

Sc3_Copper_04_CopperTrunk_v1.indd   51

12/11/12   4:10 PM

Tyco-catalog-AMP-2013-html.html
background image

3-52

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Trunk Solutions – MRJ21 XG (10 GbE)

INTRODUCING A PRE-TERMINATED, PLUG-AND-PLAY 10 GBE COPPER SYSTEM

The MRJ21 XG solution from TE Connectivity (TE) is a pre-terminated copper cabling 
system designed to deliver 10 GbE throughput in all architectures where copper 
cabling is required up to a 40 meter distance. Based on the foundation of TE’s 
industry-leading MRJ21 high-density interface, the MRJ21 XG system helps facilitate 
management of data center rack and fl oor space, density and throughput while also 
capitalizing on its ease of deployment and fast installation rates.

Due to the increasing penetration of 10GBASE-T switches and blades in the data 
center, the need to quickly deploy a 10 GbE copper system with minimal white space 
consumption has become critical. The MRJ21 XG answers this challenge in 3 ways:

Space Saving

 – The unique MRJ21 XG trunk cable typically consumes 5% less 

volume than most other zone cabling solutions and up to 37% less than traditional 
twisted pair systems, thereby reducing containment costs and improving airfl ow in 
and around the servers and switches. This can positively impact both initial capital 
expenditures as well as ongoing operating costs.

Density

 – The MRJ21 XG off ers 48 RJ45 ports in a fi xed, single rack unit confi guration, 

allowing server or switch-specifi c designs with maximum rack effi

  ciency and minimal 

wasted space.

Throughput

 – The MRJ21 XG can be deployed in traditional cross-connect 

architectures, offi

  ce LAN environments and the latest server-to-core switch 

confi gurations and supports all data rates up to and including 10 Gb/s 
(Gigabits per second).

FEATURES

• 

Multi-Component System

The MRJ21 XG system is comprised of pre-terminated cable assemblies, 
patch panels, cassettes and Cat 6A shielded patch cords

• 

Multiple Deployment Options

Supports multiple Data Center architectures, including top-of-rack (ToR), 
end-of-row (EoR) and middle-of-row (MoR)

• 

Shielded Cable

Gives the highest level of signal immunity to cross-talk in the lowest 
cross-sectional area

• 

Unique 45 Degree MRJ21 Plug Design 

The MRJ21 XG trunk cable can also be ordered with a plug supporting 
45 degree rear cable entry allowing bend radius maintenance in space 
constrained installations

MRJ21 XG (10 GbE) System

48 Port Patch Panel

Sc3_Copper_04_CopperTrunk_v1.indd   52

12/11/12   4:10 PM

Tyco-catalog-AMP-2013-html.html
background image

3-53

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Trunk Solutions – MRJ21 XG (10 GbE)

  MRJ21 XG to MRJ21 XG Cable Assemblies 

FEATURES

• 

Friendly fi eld installable 10 GbE solution

• 

Dense double blade connector with off set jackscrews for latching

• 

16 pair shielded cable with 26 AWG solid conductors

• 

Available with CMR sheath

• 

Factory terminated and 100% tested solution

ORDERING INFORMATION 

Description

Part Number

MRJ21 XG to MRJ21 XG, 10 Gb/s, 180°–180° back shell; CMR sheath; White

 TMRJ-XSSRW-SSXXXM

MRJ21 XG to MRJ21 XG, 10 Gb/s, 180°–45° back shell; CMR sheath; White

 TMRJ-XSSRW-SAXXXM

XXX - denotes meters 
Contact customer service for additional lengths. 

XXX

Length

003

3 m

005

5 m

010

10 m

015

15 m

020

20 m

025

25 m

030

30 m

035

35 m

040

40 m

Category 6A Shielded Patch Cable Assemblies

TE's XG Category 6A shielded patch cable assemblies are manufactured using 
patented techniques that create consistent performance superior to standard 
cable assemblies. The cable assemblies are CM (PVC) rated and constructed using 
colored, stranded cable and clear polycarbonate snagless boots.

ORDERING INFORMATION

Description 

Part Number

Black 

 1933880-X

Gray

 1933881-X

Blue

 1933882-X

Green 

 1933883-X

Red 

 1933884-X

White 

 1933885-X

Yellow 

 1933886-X

Orange 

 1933887-X

Violet

 1933888-X

X denotes length in feet
Contact customer service for available lengths.

Sc3_Copper_04_CopperTrunk_v1.indd   53

12/11/12   4:10 PM

Tyco-catalog-AMP-2013-html.html
background image

3-54

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Trunk Solutions – MRJ21 XG (10 GbE)

MRJ21 XG 19-Inch Patch Panel, 1RU, Straight

FEATURES

• 

Compatible with MRJ21 XG cable assemblies for 
10 GbE performance

• 

Optimal for use in environments where high density is required

• 

Straight panel with either 24 or 48 ports on 1RU

• 

Factory terminated and tested solution

ORDERING INFORMATION

Description

Part Number

Straight panel 1RU for 10 GbE; MRJ21 Plugs: 6; RJ-45 Ports: 24; Black (RAL 9005)

2153041-1

Straight panel 1RU for 10 GbE; MRJ21 Plugs: 12; RJ-45 Ports: 48; Black (RAL 9005)

2153046-1

MRJ21 XG Cassette Patch Panel

FEATURES

• 

19-inch 1RU unloaded patch panel with 4 cut outs

• 

Accepts MRJ21XG cassettes

• 

Modular rear cable bracket to manage and bundle cabling

• 

Includes grounding bolt

ORDERING INFORMATION

Description

Part Number

MRJ21 XG Cassette Patch Panel 1RU Flat; Black (RAL 9005)

1-1671594-1

48 Port Patch Panel

MRJ21 XG Quick-Fit Cassette 8 Port (10 Gb/s)

FEATURES

• 

Compatible with MRJ21 XG cable assemblies for 10 GbE performance

• 

Front side: 8 x RJ45 jack (2 rows of 4 jacks)

• 

Rear side: 2 x MRJ21 receptacle

• 

Factory terminated and tested solution

ORDERING INFORMATION

Description

Part Number

MRJ21 XG Quick-Fit cassette for 10GBase-T; Black (RAL 9005)

0-2153115-1

Sc3_Copper_04_CopperTrunk_v1.indd   54

12/11/12   4:10 PM

Tyco-catalog-AMP-2013-html.html
background image

3-55

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Trunk Solutions – MRJ21 1GbE

MRJ21 Ultra Slim Cable Assemblies

FEATURES

• 

Common and additional cable assembly lengths are available - contact your
local sales engineer for more information

• 

Enables 25% less power per port than 4 pair connector on active electronics

• 

Improves uptime and space efficiency on site

• 

50-60% less cable mass in pathways and spaces than comparable 4-pair cabling

• 

Improves airflow in cabinets and around active electronics

• 

40% less weight than comparable 4-pair cabling

• 

Gigabit Ethernet channel performance

• 

30 meters application length restrictions apply

• 

RoHS compliant

0.365 inch (9.2 mm),

24-pair MRJ21 Ultra Slim 

Cable Size Comparison

Pencil

Ultra Slim 

Cable

Standard 

MRJ21 

Cable

Description

Rating

Jacket Color

Length

Part Number

MRJ21 Ultra Slim, 
180° Back Shell

CMR (Riser)

Gray

2 m (6.56')

TMRJ-1UURG-SS002M

3 m (9.84')

TMRJ-1UURG-SS003M

4 m (13.12')

TMRJ-1UURG-SS004M

5 m (16.40')

TMRJ-1UURG-SS005M

6 m (19.68')

TMRJ-1UURG-SS006M

7 m (22.97')

TMRJ-1UURG-SS007M

8 m (26.25')

TMRJ-1UURG-SS008M

9 m (29.53')

TMRJ-1UURG-SS009M

10 m (32.81')

TMRJ-1UURG-SS010M

12 m (39.37')

TMRJ-1UURG-SS012M

15 m (49.21')

TMRJ-1UURG-SS015M

17 m (55.77')

TMRJ-1UURG-SS017M

20 m (65.62')

TMRJ-1UURG-SS020M

25 m (82.02')

TMRJ-1UURG-SS025M

30 m (98.42')  TMRJ-1UURG-SS030M

ORDERING INFORMATION

Sc3_Copper_04_CopperTrunk_v1.indd   55

12/11/12   4:10 PM

Tyco-catalog-AMP-2013-html.html
background image

3-56

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Trunk Solutions – MRJ21 1GbE 

Description

Accepts

Part Number

MRJ21 Cassette Panel

3 MRJ21 Cassettes

1479451-1

MRJ21 Cassette Panel (1GbE) 

MRJ21 1 GbE cassette panels accept up to three MRJ21 
cassettes.

ORDERING INFORMATION

MRJ21 1 GbE Cassettes

FEATURES

• 

High-performance copper cabling solution

• 

High-density, small form factor connectivity

• 

Factory terminated and tested

• 

Modular, pluggable design

• 

6-Port cassettes support applications which use four or fewer
pairs including 10BASE-T, 100BASE-T and 1000BASE-T

• 

12-Port cassettes support applications which use two or
fewer pairs including 10BASE-T, and 100BASE-T

• 

Blank adapter plate for MRJ21 (1479451-1) panel only –
Do not use 1777046-1 with optical fiber enclosures

Description

Port Count

Applications

Active Pairs Per Port Figure

MRJ21 Connections (Back)

Part Number

Cassette

6

10/100/1000BASE-T

4

A

1

1479459-1

12

10/100BASE-T

2

B

1

1479452-1

Blank

C

1777046-1

ORDERING INFORMATION

Figure A

Front

Figure B

Figure A

Back

Figure C

Sc3_Copper_04_CopperTrunk_v1.indd   56

12/11/12   4:10 PM

Tyco-catalog-AMP-2013-html.html
background image

3-57

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Trunk Solutions – MRJ21 1GbE

FEATURES

• 

Improved overall system performance

• 

New ergonomic features for easier handling

• 

New strain relief system provides:

Shorter overall connector length

Improved strain relief

Better bend radius control

• 

Backward compatible to existing panels

• 

MRJ21 cable assemblies’ small foot print reduces cable bulk in pathways
and conduits

• 

25-pair, unshielded, 24 AWG conductors

• 

Improves uptime and space effi ciency on site

• 

RoHS compliant

• 

MRJ21 to RJ45 hydra cable assemblies are wired so that all 4-pairs of the
RJ45 are active for Gigabit Ethernet

• 

Most assemblies are available with riser rated (CMR) or plenum rated
(CMP) jacketing

• 

Factory terminated, tested and serialized

Figure C

RJ45 x 6

Next Generation MRJ21 1GbE Assemblies

Description

Figure

Connector Type

Rating 

Part Number

Standard

A

Straight to Straight, 180-180

0

CMR

 TMRJ-1SURG-SS0xxM

CMP

 TMRJ-1SUPB-SS0xxM

B

Straight to Angle, 180-45

0

CMR

 TMRJ-1SURG-SA0xxM

CMP

 TMRJ-1SUPB-SA0xxM

C

Straight to Hydra 6-leg, 180-RJ45

CMR

 TMRJ-1SURG-SH0xxM

CMP

 TMRJ-1SUPB-SH0xxM

Angle to Hydra 6-leg, 45-RJ45

CMR

 TMRJ-1SURG-AH0xxM

Ultra Slim

Straight to Straight, 180-180

0

CMR

 TMRJ-1UURG-SS0xxM

ORDERING INFORMATION

Note: xxM denotes length in meters
Contact Customer Service for available lengths.

Figure A  MRJ21 45°

Back Shell

Figure B  MRJ21 180°

Back Shell

Description

Accepts

Part Number

MRJ21 Cassette Panel

3 MRJ21 Cassettes

 1479451-1

Description

Port Count

Applications

Active Pairs Per Port Figure

MRJ21 Connections (Back)

Part Number

Cassette

6

10/100/1000BASE-T

4

A

1

 1479459-1

12

10/100BASE-T

2

B

1

 1479452-1

Blank

C

 1777046-1

Sc3_Copper_04_CopperTrunk_v1.indd   57

12/11/12   4:10 PM

Tyco-catalog-AMP-2013-html.html
background image

3-58

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Trunk Solutions – MRJ21 1GbE

Figure C

Back

MRJ21 1 GbE Patch Panels

FEATURES

• 

High-performance copper cabling solution

• 

High-density, small form factor connectivity

• 

Factory terminated and tested

• 

Modular, pluggable design

• 

4-Pair MRJ21 patch panels support applications
which use four or fewer pairs including
10BASE-T, 100BASE-T and 1000BASE-T

• 

2-Pair MRJ21 patch panels support
applications which use two or fewer pairs
including 10BASE-T, and 100BASE-T

Description

Port Count

Applications

MRJ21 Connections

Back

Footprint Figure Part Number

MRJ21 Patch Panels, 1RU

24

10/100/1000BASE-T

4

Standard

A

1777029-1

48

10/100/1000BASE-T

8

Standard

B

1435971-1

Angled

C

1777052-1

10/100BASE-T

4

Standard

1435965-1

Figure A

Figure B

Figure C 

Front

ORDERING INFORMATION

Description

Depth

Figure

Part Number

Standard Support Bar

5”

A

557548-1

MRJ21 Cable Manager Bar

6”

B

1933352-1

9”

1933352-2

12”

1933352-3

16”

1933352-4

Cable Support Bars

FEATURES

• 

Mounts to the back of 19-inch racks

• 

Designed to provide additional cable support and routing control behind
19-inch racks and panels

• 

MRJ21 slotted manager bar for easy tie down

• 

Horizontal and vertical mounting option for MRJ21 tie down bar

Figure A

Figure B

ORDERING INFORMATION

Sc3_Copper_04_CopperTrunk_v1.indd   58

12/11/12   4:11 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Trunk Solutions – MRJ21

3-59

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

ORDERING INFORMATION

Description

Footprint

Figure

Part Number

Label Holder Panel

(Labels sold separately)

Standard

A

1777040-1

Angled

1777054-1

Part Number

Color

5 Sheets/Pack 

Labels for 22 Panels

100 Sheets/Pack 

Labels for 450 Panels

Label Sheet

White

1375354-1

5-1375354-1

Blue

1375354-2

5-1375354-2

Green

1375354-3

5-1375354-3

Figure A

MRJ21 Label Holder Panels and Labels

Description

Port Count

Applications

MRJ21 Connections

Back

Footprint Figure Part Number

MRJ21 Patch Panels, 1RU

24

10/100/1000BASE-T

4

Standard

A

1777029-1

48

10/100/1000BASE-T

8

Standard

B

1435971-1

Angled

C

1777052-1

10/100BASE-T

4

Standard

1435965-1

Sc3_Copper_04_CopperTrunk_v1.indd   59

12/11/12   4:11 PM

Tyco-catalog-AMP-2013-html.html
background image

3-60

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Trunk Solutions – Sigma-Link 

Sigma-Link

The Sigma-Link solutions from TE Connectivity are pre-terminated cabling systems 
for high-speed networking applications. Sigma-Link cable assemblies are factory 
terminated and tested. Designed for quick, easy, reliable operation in data centers. 
Plus, all components are fully compliant with TIA-942 and EN 50173-5 data 
center standards.

TE's Sigma-Link systems are the perfect solution for equipment cabling that links 
data center servers to cabling distributors or cross connects. For smaller data 
centers, pre-terminated Sigma-Link products can also provide a server to 
switch-cabling solution with an upgrade path to 40 Gbps. Sigma-Link products 
also support open offi

  ce applications that require multiple distribution points in a 

raised fl oor or ceiling.

FEATURES

• 

Pre-terminated

• 

Faster installation time

• 

100% factory tested

• 

Performance levels:

UTP: TIA-568-C.2 Category 6

F/UTP: TIA-568-C.2 Category 6A

• 

Termination confi gurations:

Cassette-to-cassette

Cassette-to-plug

Cassette-to-open-end

• 

Length options from 7' – 295'

• 

Easy, “single-handed” release feature on cassettes

Sc3_Copper_04_CopperTrunk_v1.indd   60

12/11/12   4:11 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Trunk Solutions – Sigma-Link

3-61

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

FEATURES

• 

Meets or exceeds component performance requirements of TIA/EIA-568-C.2

• 

Six bundled 4-pair, solid conductor, riser (CMR) rated, Category 6 UTP cables

• 

Available in three confi gurations:

Cassette-to-cassette

Cassette-to-plug

Cassette-to-unterminated/open

• 

Each cassette houses six Category 6 SL Series modular jacks, wired with all 
4-pairs active

• 

Other lengths available, see customer drawing for details

Assembly

Available Lengths

7–25' (1' Increments)

26–64' (2' Increments)

75–95' (10' Increments)

105–195' (10' Increments) 200 – 295' (10' Increments)

End A

End B

7'

25'

26'

64'

75'

95'

105'

195'

205'

295'

Cassette

Cassette

 2111290-7

 2-2111290-5

 2-2111290-6  6-2111290-4

 7-2111290-5

 9-2111290-5  2111291-5

 9-2111291-5

 2111292-5

 9-2111292-5

Plug

 2111300-7

 2-2111300-5  2-2111300-6  6-2111300-4

 7-2111300-5

 9-2111300-5  2111301-5

 9-2111301-5

 2111302-5

 9-2111302-5

Open

 2111310-7

 2-2111310-5

 2-2111310-6

 6-2111310-4

 7-2111310-5

 9-2111310-5

 2111311-5

 9-2111311-5

 2111312-5

 9-2111312-5

Sigma-Link Cat6 UTP Cable Assemblies

ORDERING INFORMATION

Sc3_Copper_04_CopperTrunk_v1.indd   61

12/11/12   4:11 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Trunk Solutions – Sigma-Link

3-62

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

FEATURES 

• 

Meets or exceeds component performance requirements of 
TIA/EIA-568-C.2

• 

Six bundled 4-pair, solid conductor, riser (CMR) rated, 
Category 6A F/UTP cables

• 

Available in three confi gurations:

Cassette-to-cassette

Cassette-to-plug

Cassette-to-unterminated/open

• 

Each cassette houses six Category 6A AMP-TWIST modular jacks, 
wired with all 4-pairs active

• 

Other lengths available, see customer drawing for details

FEATURES 

• 

19-inch unloaded panel accommodates four Sigma-Link cassettes

• 

Features integrated cable management bar

Description

Part Number

Sigma-Link Patch Panel, 1RU H, 19" W, Standard (Flush) Footprint

 1-1671215-1

Assembly

Available Lengths

7–25' (1' Increments)

26 – 64' (2' Increments)

75 – 95' ( 10' Increments) 105 – 195' (10' Increments)

200 – 295' (10' Increments)

End A

End B

7'

25'

26'

64'

75'

95'

105'

195'

205'

295'

Cassette Cassette

 2111250-7  2-2111250-5  2-2111250-6  6-2111250-4  7-2111250-5  9-2111250-5

 2111251-5

 9-2111251-5

 2111252-5

 9-2111252-5

Plug

 2111270-7  2-2111270-5

 2-2111270-6  6-2111270-4  7-2111270-5  9-2111270-5

 2111271-5

 9-2111271-5

 2111272-5

 9-2111272-5

Open

 2111280-7  2-2111280-5  2-2111280-6  6-2111280-4  7-2111280-5  9-2111280-5

 2111281-5

 9-2111281-5

 2111282-5

 9-2111282-5

Sigma-Link Patch Panel

Sigma-Link Cat6A F/UTP Cable Assemblies

ORDERING INFORMATION

ORDERING INFORMATION

Sc3_Copper_04_CopperTrunk_v1.indd   62

12/11/12   4:11 PM

Tyco-catalog-AMP-2013-html.html
background image

3-63

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Universal Connectivity Platform

Universal Connectivity Platform — 
A Modular Approach to Infrastructure Design

Sc3_Copper_05_Specialty_v1.indd   63

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

3-64

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Universal Connectivity Platform

UCP Patch Panel

FEATURES

• 

19” 1RU unloaded modular patch panel with 4 UCP cutouts

• 

Modular rear cable bracket to manage and bundle different media cabling

• 

Accepts pre-terminated copper or fiber cassettes or field terminated 
copper or fiber modules

Description

Part Number

UCP Patch Panel 1RU Flush;

 includes grounding bolt

1-1671594-1

UCP Drawer Style Enclosure

FEATURES

• 

19" 1RU enclosure with 4 UCP cutouts

• 

Mounting bracket for front or center mounting

• 

includes cable tie-down bars

Description

Part Number

1RU Drawer style Enclosure

 

 

1933443-1

Zero RU Quick-Fit Module Bracket

FEATURES

• 

Panel designed for copper and fiber Quick-Fit cassettes and modules

• 

5" horizontal clearance required 

Description

Part Number

Zero RU Quick-Fit Module Bracket;

 includes grounding bolt

1-1671548-1

Sc3_Copper_05_Specialty_v1.indd   64

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

3-65

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Universal Connectivity Platform

Description

Fiber Type

Fiber Count

Part Number

LC Duplex 

 50

µ

m, MM, OM3

12

 1671205-3

9

µ

m, SM, OS2

12

 1671205-4

50

µ

m, MM, OM4 OPTIMATE

12

 1671226-5

LC Quad 

50

µ

m, MM, OM3

24

 1671206-3

9

µ

m, SM, OS2

24

 1671206-4

50

µ

m, MM, OM4 OPTIMATE

24

 1671227-5

MRJ21 Quick-Fit Cassettes

FEATURES

• 

Pre-terminated Quick-Fit cassettes

• 

Available in 10 GbE and 1 GbE

• 

Compatible with MRJ21 cable assemblies for superior performance

• 

High-density, small form factor connectivity

• 

Integrated bonding

Description

Part Number

MRJ21 XG Quick-Fit cassette for 10GBase-T

 2153115-1

MRJ21 Quick-Fit cassette for 1000BaseT

 1711970-1

10 GbE

MPOptimate to LC Quick-Fit Cassettes

FEATURES

• 

Pre-terminated MPO cassettes

• 

Front: 6 x LC Duplex or 6 x LC Quad

• 

Back: 1 or 2 12-fi ber MPO or MPOptimate connector(s)

• 

Available in OS2, OM3 or OM4 Optimate

• 

Port number labeling and additional label strip included

• 

Fiber path for part numbers noted is "straight-through"
(A to A, B to B).  Other Fiber paths are available

STP and UTP Quick-Fit Modules

FEATURES

• 

Accommodates various SL jacks: Cat 5e, 6, 6A

• 

STP version has integrated bonding

• 

Labels included

Description

Part Number

STP Quick-Fit module (1 pc)

 2111093-1

UTP Quick-Fit module (1 pc)

 2111117-1

Blank Module; 

used to close unused cut-outs in panels

 1479698-1

Blank Module

LC Duplex

LC Quad

Quick-Fit Module

1 GbE

Sc3_Copper_05_Specialty_v1.indd   65

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

3-66

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Universal Connectivity Platform

Description        Fiber Type                               Fiber Count         Part number 

                           50

µ

m, MM, OM3                               12                    1671205-3 

 LC Duplex         9

µ

m, SM, OS2                                   12                   1671205-4 

                           50

µ

m, MM, OM4 OPTIMATE            12                   1671226-5 

                           50

µ

m, MM, OM3                                24                   1671206-3 

  LC Quad           9

µ

m, SM, OS2                                   24                   1671206-4 

                           50

µ

m, MM, OM4 OPTIMATE             24                   1671227-5 

MPOptimate to SC Quick-Fit Cassettes

FEATURES

• 

Pre-terminated MPO cassettes

• 

Front: 6 x SC Duplex

• 

Back: 1 x MPO connector

• 

Available in OS2 or OM3

• 

Port number labeling and additional label strip included

• 

Fiber path for part numbers noted is "straight-through"
(A to A, B to B).  Other Fiber paths are available

MPO/MPOptimate Coupler Quick-Fit Module

FEATURES

• 

Quick-Fit module with 6x or 12x MPO coupler

• 

Port number labeling and additional label strip included

• 

MPO coupler always used with on one side MPO male
and other side MPO female connector

Description

Part Number

6x MPO coupler module

 1671200-1

12x MPO coupler module                                                          

 1711987-1

 Quick-Fit Fiber Coupler Modules

FEATURES

• 

Universal Modules with Quick-Fit footprint

• 

Fits in all TE AMP NETCONNECT Patch Panels with Quick-Fit footprint

• 

Enclosure 1933443-1 is recommended if splice storage is required

Description

Fiber Type

Ferrule

Color

Figure

Part Number

6x LC duplex

 OM3/OM4 XG 10 Gb/s

Ceramic

aqua

A

 0-1671196-3

6x LC duplex

SM

Ceramic

blue

A

 0-1671196-1

6x LC quad

OM3/OM4 XG 10 Gb/s

Ceramic

aqua

B

 0-1671202-3

6x LC quad 

SM

Ceramic

blue

B

 0-1671202-1

A

B

Fiber Type

Fiber Count

Part Number

 50

µ

m, MM, OM3

12

 1671207-3

9

µ

m, SM, OS2

12

 1671207-4

Sc3_Copper_05_Specialty_v1.indd   66

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

3-67

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Universal Connectivity Platform

Vertical Panel Mounting Brackets

FEATURES

• 

Fully fl exible system for installing 19” panels vertically outside of the 19” area

• 

Available in 1RU

Description

Part Number

1RU Vertical Panel Mounting Brackets

 1-1671549-1

Subfloor Panel Holder Kit

FEATURES

• 

Fully fl exible system for installing 19” panels underneath
cabinets/racks in the false fl oor area

• 

Pedestal distance maximum 24"

• 

The clamping range varies from .6" up to 1.2"

• 

Pedestal can be round or square

• 

Available in 2RU

Description

Part Number

Subfl oor Panel Holder Kit 2RU

 1671189-2

Aerial Panel Holder Kit for Wire Mesh Cable Trays

FEATURES

• 

Fully fl exible system for installing 19” panels above cabinets/racks
attached to wire mesh cable trays

• 

Available in 2RU

Description

Part Number

Aerial Panel Holder Kit (2RU)

 1-1671603-1

Sc3_Copper_05_Specialty_v1.indd   67

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

3-68

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – High Speed Copper Cable Assemblies

TE Connectivity's (TE) SFP+ and QSFP/QSFP+

TE Connectivity's (TE) SFP+ and QSFP/QSFP+ direct attach copper cable 
assemblies are a high speed, cost effective alternative to fiber optics in 10 
Gb Ethernet, 8 Gb Fiber Channel and InfiniBand technology applications. 
These high speed copper cable assemblies enable hardware OEM’s and 
data center operators to achieve higher port density and configurability at 
a low cost and reduced power requirement. The QSFP copper cable form 
factor utilizes eight differential pairs which provide four data transmission 
channels. TE's SFP+ and QSFP copper assemblies meet or exceed the 
industry MSA for signal integrity performance.

FEATURES

• 

MSA SFF-8431 compliant

• 

Supports serial data rates up to 10 Gbps

• 

Low cost alternative to fiber optic assemblies

• 

Low power consumption

• 

Enhanced EMI suppression

• 

Pull-to-release retractable pin latch

• 

24 AWG through 30 AWG cable available

• 

Passive and active assemblies

• 

Uses MADISON CABLE brand TurboTwin parallel pair cable

PRODUCT APPLICATIONS

• 

Switches

• 

Networking – servers, routers and hubs

• 

Enterprise storage

• 

Telecommunication equipment

• 

Network Interface Cards (NIC’s)

APPLICATIONS BY PROTOCOL

• 

10 Gigabit Ethernet and Gigabit Ethernet (IEEE802.3ae)

• 

Fibre channel: 1-, 2-, 4-, 8-, and 16-GFC

• 

InfiniBand standard SDR (2.5 Gbps), DDR (5 Gbps) and QDR (10 Gbps)

• 

Fibre Channel over Ethernet (FCoE)

• 

Serial data transmission

QSFP/ASFP+

SFP

Sc3_Copper_05_Specialty_v1.indd   68

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

3-69

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – High Speed Copper Cable Assemblies

SFP+ High Speed Copper Cable Assemblies

QSFP/QSFP+ High Speed Copper Cable Assemblies

AWG

Cable Length

Active/Passive

Data Rate

Part Number

24

.05m

Passive

10Gbps

9-2111653-1

24

1.0m

Passive

10Gbps

2111653-1

24

2.0m

Passive

10Gbps

2111653-2

24

3.0m

Passive

10Gbps

2111653-3

24

5.0m 

Passive

10Gbps

2111653-5

24

7.0m

Passive

10Gbps

2111653-7

AWG

Cable Length

Active/Passive

Data Rate

Part Number

30

0.5m

Passive

5/10 Gbps

9-2111673-1

30

1.0m

Passive

5/10 Gbps

2111673-1

30

2.0m

Passive

5/10 Gbps

2111673-2

30

3.0m

Passive

5/10 Gbps

2111673-3

26

5.0m

Passive

5/10 Gbps

2111673-5

Other lengths and cable guages avaliable. Contact your local TE Sales Engineer.

ORDERING INFORMATION 

ORDERING INFORMATION 

Sc3_Copper_05_Specialty_v1.indd   69

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

3-70

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – High Speed Copper Cable Assemblies

CABLE OD

24 AWG

26 AWG

28 AWG

30 AWG

SFP

0.255 in

0.205 in

0.185 in

0.170 in

QSFP/QSFP+

-

0.350 in

0.310 in

0.255 in

CONNECTOR

Interface 

PCB paddle card

Contact Material 

30

μ

 Gold plated contact pads

Backshell Material 

Tin plated Zinc diecast

EMI Spring 

Tin plated copper alloy

Latch 

Retractable pin

Latch Release 

Molded thermoplastic pull tab

Retention Force 

90N Max

Durability 

100 cycles Min

TWIN AXIAL CABLE

Operating Temp 

0 to +70 deg C

Storage Temp 

-40° to +80°C

Inner Shield 

Aluminum/Poly Tape

Outer Shield 

Tin Plated Copper Braid

 Safety Certications

UL Recognized

CSA Certified

RoHS Compliant

REACH 2010 Compliant

Impedance 

100 ± 10 Ohms

Jacket Material 

Flexible PVC

Bend Radius

3x OD Static

5x OD Dynamic

SPECIFICATIONS

Sc3_Copper_05_Specialty_v1.indd   70

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Specialty Products

3-71

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Video Distribution System

Video Distribution System (VDS)

TE Connectivity’s Video Distribution System (VDS) enables network managers to 
deliver true high-definition RF and IP video over an existing Category 6 or 7 cabling 
infrastructure without the need for coaxial horizontal cabling or any RF tuning.

VDS enables the delivery of video signals such as cable television, satellite, in-house 
video, digital signage, electronic bulletin boards or any other service normally 
delivered over coaxial systems—but over a Category 6 or Category 7 twisted-pair 
infrastructure. The VDS eliminates the need for a separate coaxial infrastructure or 
the need for an RF technician to install it. 

More information on the Video Distribution System can be found 
at www.te.com/VDS.

FEATURES

VDS is a TIA-568/ISO 11801 compliant solution providing these key benefits:

• 

Provides full RF video spectrum, along with IP video, over a single Cat 6/7 cable: 
Compatible with standard Structured Cabling guidelines and specifications. 
Eliminates the need for horizontal coax cabling. Supports full-spectrum video 
862 MHz for up to 90 meters or 550 MHz for up to 100 meters

• 

Future proofing: Cat 6/7 system provides a migration path to tomorrows 
broadcast IPTV

• 

Auto adjusting RF signal: Eliminates the need for manual tuning. Solves Coax’s 
equalizing and balancing problems electronically via Auto Gain Control (AGC)

• 

Plug-and-play solution: Provides ease of installation and system design/
maintenance. Output and input levels are adjusted to provide perfect HD video at 
the TV set

• 

Head-end output—Automatically Adjusted: The Master RF Interface adjusts the 
head-end signal for proper system operation

• 

Powered over cable: The Remote Active Balun is powered over the twisted pair 
system, with +12 Volts being applied at the video distribution hub

• 

Bi-directional signaling: Compatible with interactive control requirements 

• 

Global Support: Two variants available based on bandwidth allocation—
P version for PAL and N version for NTSC specifications

• 

Capability to support in excess of 65,000 video drops

Sc3_Copper_05_Specialty_v1.indd   71

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Specialty Products

3-72

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Video Distribution System

Master RF Video Interface

FEATURES

• 

No set-up required – plug-and-play

• 

Automatic RF gain and slope adjustment

• 

Eight coax output ports to drive VDS Hubs

• 

Auxiliary ports for use with in-house RF video 

• 

LED indicator lights

Description

Part Number

Master RF Video Interface (N Variant)

2-2111501-0

Master RF Video Interface (P Variant)

1-2111501-0

Video Distribution Hub

FEATURES

• 

No set-up – automatic gain and slope control

• 

Supports full-spectrum video as well as 10/100Base-T

• 

Available in 12 and 24-port versions

• 

Four (4) coax output ports to drive other VDS Hubs

• 

LED indicator lights

Description

Part Number

Video Distribution Hub (N) 24-port 

2-2111510-0

Video Distribution Hub (P) 24-port 

1-2111510-0

Video Distribution Hub (N) 12-port 

2-2111505-0

Video Distribution Hub (P) 12-port 

1-2111505-0

Power Cordage

Power supply included (C13 connector), power cord ordered separately

Description

Part Number

Power cord; 

6 feet

USA plug (Type B)

1591311-1

Europe plug (Type E)

1591311-2

AZ/NZ plug (Type I)

1591311-6

UK plug (Type G)

1591311-7

Intelligent, Self-Adjusting Balun
 

FEATURES

• 

Plug-and-play utilizing AGC (Automatic Gain Control)

• 

Provides two output ports – F connector for RF and RJ-45 for 10/100Base-T

• 

No external power supply – powered via twisted pair cable

• 

Small size (2.5" x 2.5" x 1") (59 mm x 57 mm x 24 mm)

Description

Part Number

Intelligent, Self-Adjusting Balun (N) 

2-2111515-0

Intelligent, Self-Adjusting Balun (P) 

1-2111515-0

Sc3_Copper_05_Specialty_v1.indd   72

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Specialty Products

3-73

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Media Converters and Switches

Media Converters, Switches and Mid-Span POE

TE Connectivity offers a wide range of high-performance, cost-effective AMP 
NETCONNECT Ethernet switches. The AMP NETCONNECT switches include 
unmanaged compact Ethernet switches, smart Ethernet switches with built-in or 
optional fiber uplink ports and SNMP managed Ethernet switches with optional 
fiber or twisted pair Gigabit uplink ports.

TE's AMP NETCONNECT basic, unmanaged compact Ethernet switches are ideal 
for Small Office/Home Office (SOHO), small workgroup or home networking 
applications. Smart Ethernet switches have fiber uplink ports either built-in/fixed 
(8-port switch only) or optional (16- and 24-port switches) to enable 
high-speed connections to backbones, servers, and network devices over 
singlemode or multimode (50 or 62.5/125 

μ

m) fiber using industry standard 

MT-RJ, SC, and ST-Style connectors. SNMP managed Ethernet switches deliver 
management capabilities required by most network managers using interfaces 
such as direct connection to a console port, Telnet, or web browser sessions. 
Optional fiber or twisted pair uplinks can be added for high-speed network 
interface. Fiber uplinks include singlemode and multimode (50 or 62.5/125 

μ

m) 

Gigabit (1000BASE-SX or LX) and 100BASE-FX. Optional twisted pair uplink 
is via an RJ-45, 100/1000BASE-T interface. These uplinks can be used in any 
combination on the switch to deliver a highly flexible backbone solution. With an 
emphasis on high quality, competitive cost, and ease of use, AMP NETCONNECT 
Ethernet switches from TE are a great choice for anyone from a home office 
user to an enterprise IT manager.

Sc3_Copper_05_Specialty_v1.indd   73

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Specialty Products

3-74

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Media Converters and Switches

AMP NETCONNECT Smart Ethernet Switches

AMP NETCONNECT smart Ethernet switches from TE can be mounted in either 
10-inch or 19-inch frames. 

AMP NETCONNECT SNMP Managed Ethernet Switches 

TE's AMP NETCONNECT SNMP managed Ethernet switches allow network managers 
excellent control and visibility of distributed switches using advanced functions 
accessible through a direct connection to the console port, Telnet or web browser 
sessions, or SNMP programs. This capability is ideal for network managers who want 
to have versatile control of their network.

AMP NETCONNECT Ethernet Media Converters 

TE's AMP NETCONNECT Ethernet media converters are high quality media conversion 
products that support 10BASE-T, 100BASE-TX and Gigabit (1000BASE-T) Ethernet 
standards and can be used in a wide range of applications including office buildings, 
professional workgroups, campuses, Fiber-to-the-Desk (FttD), and industrial systems.

Media converters are used to extend Ethernet segments or LANs to servers and other 
network elements using singlemode or multimode (50 or 62.5 

µ

m) optical fibers 

connectorized with the MT-RJ, SC, or ST connectors.

With a strong focus on simple, cost effective, quality installations, AMP NETCONNECT 
media converters enable a wide range of reliable network solutions.

AMP NETCONNECT Power over Ethernet Products 

TE's AMP NETCONNECT 8-port & 24-port Power over Ethernet (PoE) Midspan device 
for 802.3af applications offers a per-port, cost-effective solution when powering 
remote devices like VoIP phones, WLAN access points, security devices, etc. The 
AMP NETCONNECT 8-port and 24-port PoE midspan devices from TE makes injecting 
DC power onto existing copper cabling as simple as routing patch cords and it 
eliminates the PoE costs for powered switch ports when power is not needed.

Sc3_Copper_05_Specialty_v1.indd   74

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Specialty Products

3-75

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Media Converters and Switches

5, 8 and 16-Port Compact Ethernet Switch

FEATURES

• 

Compact and easy to install Ethernet switches

• 

Ideal for Small Office/Home Office (SOHO), small business and home
networking applications

• 

Supports 10BASE-T, 100BASE-TX, 1000BASE-T Ethernet applications

• 

For use with RJ-45, shielded or unshielded, Category 6, 5e and 5 twisted
pair structured cabling systems

• 

Data rate auto-negotiation and full or half duplex mode auto-selection

• 

Auto MDI/MDI-X detection eliminates the need for crossover cable
assemblies

• 

Strong metal case helps to protect the switch against damage

• 

Powered via a compact external AC power adapter

Description

Port Count

Ethernet Speed (MBps)

Figure

Part Number

Compact Ethernet Switch

5

10/100/1000

A

1591081-1

8

10/100/1000

B

1591083-1

16

C

1591070-1

ORDERING INFORMATION

Figure A

Figure B

Figure C

ORDERING INFORMATION

24-Port Smart Ethernet Switch II with Optional Dual Uplink Port

FEATURES

• 

Supports 10BASE-T, 100BASE-TX, and Fast Ethernet standards

• 

Optional dual or single fiber uplink module only
needs to be fitted if fiber link is required

• 

Fully managed smart switch II through the RS232 console port

• 

Supports up to 26 port-based VLANs

• 

Supports QoS (802.1p, DiffServ and port based)

• 

Programmable port speeds and duplex modes

Description

Figure

Part Number

24-Port Smart Ethernet Switch II

D

1591093-1

Figure D

Sc3_Copper_05_Specialty_v1.indd   75

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Specialty Products

3-76

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Media Converters and Switches

24-Port Stackable Managed Switch with Optional
Expansion Port

FEATURES

• 

Supports 10BASE-T, 100BASE-TX, and Ethernet applications

• 

Available uplink modules provide optional fiber 100BASE-FX or optical fiber
or copper gigabit capabilities

• 

Supports full of half-duplex auto-negotiation together with N-Way
capability on the RJ-45 port

• 

Auto-MDI/MDI-X eliminates the need for RJ-45 crossover cables

• 

Managed and controlled from a console port, Telnet, SNMP or web browser

• 

IP stackable management supporting 8 separate switches

• 

VLANs, IGMP and QoS support

• 

Static MAC address port security

• 

Programmable bandwidth rules

• 

Comprehensive LED indicators

• 

Programmable port mirroring

• 

Up to 7-port trunks supported

• 

Supports 802-1x user authentication

Description

Figure

Part Number

24-Port Stackable Managed Switch

A

1591099-1

Description

Application

Interface Type

Figure

Part Number

Optional Uplink Port Modules

100BASE-Fx

SC Multimode Fiber

1591094-0

ST Multimode Fiber

1591095-0

SC Singlemode Fiber

1591096-0

Dual Gigabit

4-Fiber Multimode 1000BASE-Sx

1591097-0

4-Fiber Singlemode 1000BASE-Lx

1591098-0

2-Port Twisted Pair 1000BASE-T

B

2-1591019-0

Figure A

Figure B  

Sold Separately

ORDERING INFORMATION

Sc3_Copper_05_Specialty_v1.indd   76

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Specialty Products

3-77

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Media Converters and Switches

Figure A

Description

Optical Fiber Interface

Figure Part Number

Fast Ethernet Media Converter

SC Duplex Multimode

1591024-1

SC Duplex Singlemode

A

1591030-1

ST Multimode

1591026-1

Fast Ethernet Media Converters

FEATURES

• 

Ideal for both new and legacy LAN applications

• 

RJ-45 Port:

– For use with shielded or unshielded, Category 6, 5e, and 5 twisted pair structured

cabling systems

– Supports 10BASE-T and 100BASE-TX Ethernet applications

– Data rate auto-negotiation and full or half duplex mode auto-selection

– Auto MDI/MDI-X detection eliminates the need for crossover cable assemblies

• 

Optical Fiber Port:

– For use with MT-RJ, SC, or ST, multimode or SC singlemode optical fiber connectors

– Multimode fiber ports are compatible with 50/125

µ

m and 62.5/125

µ

m fiber types

– Supports 100BASE-FX Ethernet applications

• 

Increased network resilience through link loss forwarding function that allows suitable
Ethernet switches to implement alternate paths when required

• 

Stand-alone or chassis mountable

• 

Strong metal case helps to protect the media converter against damage

• 

Powered via an external, AC power adapter

• 

Dimensions 4.7" x 3.4" x 1.0"

ORDERING INFORMATION

Description

Figure

Part Number

24-Port Stackable Managed Switch

A

1591099-1

Description

Application

Interface Type

Figure

Part Number

Optional Uplink Port Modules

100BASE-Fx

SC Multimode Fiber

1591094-0

ST Multimode Fiber

1591095-0

SC Singlemode Fiber

1591096-0

Dual Gigabit

4-Fiber Multimode 1000BASE-Sx

1591097-0

4-Fiber Singlemode 1000BASE-Lx

1591098-0

2-Port Twisted Pair 1000BASE-T

B

2-1591019-0

Sc3_Copper_05_Specialty_v1.indd   77

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Specialty Products

3-78

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Media Converters and Switches

ORDERING INFORMATION

Figure A

Description

Figure

Part Number

1000BASE-SX SC Duplex Multimode

A

1591020-1

1000BASE-LX SC Duplex Singlemode

1591022-1

Gigabit Ethernet Media Converters

FEATURES

• 

Ideal for both new and legacy LAN applications

• 

RJ-45 Port:

– For use with shielded or unshielded, Category 6, 5e and 5 twisted pair structured

cabling systems

– Supports 1000BASE-T Ethernet applications data rate auto-negotiation and full or half

duplex mode auto-selection

– Auto MDI/MDI-X detection eliminates the need for crossover cable assemblies

• 

Optical Fiber Port:

– For use with SC multimode or singlemode fiber optic connectors

– Multimode fiber ports are compatible with 50/125

µ

m and 62.5/125

µ

m fiber types

– Supports 1000BASE-SX and 1000BASE-LX Ethernet applications

• 

Stand-alone or chassis mountable

• 

Strong metal case helps to protect the media converter against damage

• 

Powered via an external, AC power adapter

• 

Dimensions 4.7" x 3.4" x 1.0"

ORDERING INFORMATION

Media Converters Sold Separately

Description

Part Number

Empty Rack Mount Media Converter Chassis System

1591032-1

Spare/Redundant AC Power Unit

1591034-0

Rack Mount Media Converter Chassis System

• 

Mounts in standard 19" racks

• 

3U (5.25")

• 

Accepts up to ten (10) Fast Ethernet or Gigabit
Ethernet Media Converters (sold separately)

• 

Ideal for enterprise critical and networks

• 

Can be loaded with mixed types of media converters for flexibility

• 

Media converters can be hot-swapped within the chassis

• 

Media converters are purchased separately

• 

Media Converter Chassis is shipped unloaded and
includes one installed power supply

• 

A second power supply can be installed for a dual redundancy power system

• 

Power supplies can be hot swapped for critical availability networks

Sc3_Copper_05_Specialty_v1.indd   78

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Specialty Products

3-79

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Patch Panels

RJ45 Coupler Panel

TE’s RJ45 coupler panel provides feed-through data and voice connectivity
on the front and rear for Category 5e, 6 and 6A applications. Connectivity on
the front of the panel accommodates standard RJ45 patch cords. Connectivity
for hubs, routers and other active equipment on the back of the panel is also
designed for RJ45 patch cords—creating a convenient connection field for data
applications. Includes port labeling for front and rear. Width is 48.26 cm (19").

Description

Port Count

Category

Rack Units

Part Number

RJ45 coupler panel

48

Shielded 6A

1

2111340-1

24

6

1

ADCPP24606

48

6

2

ADCPP48606

24

Shielded 6

1

ADCPP24RJ6-S

24 

Shielded 5e

1

ADCPP24RJ5E-S

24

5e

1

ADCPP24505

48

5e

2

ADCPP48505

16

5e

1

ADCPP16KSRJRJ

32

5e

1

ADCPP32KSRJRJ

ORDERING INFORMATION

RJ45 coupler panel

front view

Description

Figure

Part Number

1000BASE-SX SC Duplex Multimode

A

1591020-1

1000BASE-LX SC Duplex Singlemode

1591022-1

ORDERING INFORMATION

Figure A

8-Port PoE Midspan Device

FEATURES

• 

IEEE 802.3af compliant

• 

Supports 10/100/1000 Mb/s Ethernet

• 

19-inch metal frame mountable

• 

Universal 110/220 V (50/60 Hz) power supply

• 

Full power on every port (15.4 W)

Description

Figure

Part Number

8-Port PoE Midspan

A

1591188-1

1RU, 19” Mounting Frame (holds three 8-Port PoE Midspan Devices)

B

1591185-0

Figure B

Shown Loaded with one 159118 

(Sold Separately)

Description

Part Number

Empty Rack Mount Media Converter Chassis System

1591032-1

Spare/Redundant AC Power Unit

1591034-0

Sc3_Copper_05_Specialty_v1.indd   79

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

3-80

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Patch Panels

ORDERING INFORMATION

Category 5, 10/100BASE-T, RJ21 (25-Pair) Patch Panel
and Cable Assemblies

FEATURES

• 

Meets or exceeds TIA and ISO Category 5 component performance
requirements

• 

Provides RJ45 breakouts from 10/100BASE-T switches and hubs that use
the 25-pair telecommunications interface

• 

Compatible with CISCO hubs and switches

• 

Use with 25-pair plug to plug cable assemblies listed

• 

Cable assemblies are for use with this patch panel only

• 

Saves time in moves, adds, and changes

• 

Features secure and convenient 25-pair connections on the rear

• 

Modular 8-pin, 4-pair jacks on the front

Description

Height

Length

Part Number

Category 5, 10/100BASE-T, 25-Pair Patch Panel

2RU (3.50")

1116732-1

Left-hand Exit Cable Assembly

5' (1.52 m)

1116733-5

7' (2.13 m)

1116733-7

10' (3.05 m)

1-1116733-0

15' (4.57 m)

1-1116733-5

Right-hand Exit Cable Assembly

5' (1.52 m)

1116734-5

7' (2.13 m)

1116734-7

10' (3.05 m)

1-1116734-0

15' (4.57 m)

1-1116734-5

Category 5, 10/100BASE-T 

25-Pair Patch Panel, BACK

Left-hand Exit  

Cable Assembly

Category 5, 10/100BASE-T

25-Pair Patch Panel, FRONT

Category 3 Patch Panels
 

FEATURES

• 

Meets or exceeds TIA and ISO Category 3 component
performance requirements

• 

Available in 2 and 3-pair for voice and low speed data applications

ORDERING INFORMATION

Description

Height

Wiring Pattern

Part Number

24-Port

1RU (1.75")

RJ14C (2-Pair)

557403-1 

24-Port

Sc3_Copper_05_Specialty_v1.indd   80

12/11/12   4:14 PM

Tyco-catalog-AMP-2013-html.html
background image

3-81

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Patch Panels

ORDERING INFORMATION

Port Count

Height

Width

Modular Jack Type

Active Pins

Wiring 

Diagram

Number of 25-Pair

Plugs (Male)

Part Number

24

1RU (1.75")

19"

1-Pair (6-Pos.)

3&4

A

1

 556189-1

2-Pair (6-Pos.)

2-5

C

2

 556183-1

4-Pair (8-Pos.)

1-8

F

4

 556180-1

E

4

 556186-1

48

3RU (5.25")

19"

1-Pair (8-Pos.)

4&5

B

2

 555482-1

3-Pair (6-Pos.)

1-6

D

6

 555346-1

4-Pair (8-Pos.)

1-8

E

8

 555383-1

Category 3 25-Pair Patch Panels

FEATURES

• 

Meets or exceeds TIA and ISO Category 3 component performance requirements

• 

Available in 1 through 4-pair for voice and low speed data applications

• 

25-Pair connectors on the back of the patch panels are male (plugs)

A. 1-Pair

6-Position

C. 2-Pair

6-Position

F. 4-Pair

T568A

D. 3-Pair

6-Position

B. 1-Pair

8-Position

E. 4-Pair

T568B

Category 3, 25-Pair Patch Panel 

FRONT, 24 Port Count

Category 3, 25-Pair Patch Panel 

BACK, 24 Port Count

Front Detail

Back Detail

SPECIFICATIONS

Sc3_Copper_05_Specialty_v1.indd   81

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-82

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products  - Patch Panels

Multimedia SL Series Patch Panels
 

FEATURES

• 

Shielded panels accept AMP-TWIST, shielded, and unshielded SL series jacks
and inserts

• 

Unshielded panels accept unshielded SL series jacks and inserts

• 

May be used to create custom configurations — including mixing fiber,
twisted-pair, coax and A/V applications

• 

Ports may be individually replaced

• 

Angled versions allow elimination of horizontal cable management for higher
rack densities and ease of cable dress

Blank Panels
 

FEATURES

• 

19" wide panels are designed for
use in filling equipment rack voids

ORDERING INFORMATION

Part Number

Description

Shielding

Height

Width

Standard

Angled

12-Port

Shielded

1RU (1.75")

19.0"

1933412-1

Unshielded

10.00"

2.3"

1375289-1

24-Port

Shielded

1RU (1.75")

19.0"

1933307-1

1933309-1

Unshielded

1RU (1.75")

19.0"

1375291-1

1499622-1

48-Port

Unshielded

1RU (1.75")

19.0"

2111348-1

2111349-1

Shielded

2RU (3.50")

19.0"

1933308-1

1933310-1

Unshielded

2RU (3.50")

19.0"

1375292-1

1499623-1

96-Port

Unshielded

4RU (7.0")

19.0"

2111159-1

48-Port

Unshielded

1RU

19.0"

2111348-1

2111349-1

Angled

Figure A 1U

 Standard

Figure B

1U

Figure B

2U

Description

Figure

1U [1.75"]

2U [3.50"]

3U [5.25"]

4U [7.00"]

5U [8.75"]

Standard

A

556965-1

556965-2

556965-3

556965-4

556965-5

Angled

B

1479992-1

1479992-2

ORDERING INFORMATION

Sc3_Copper_05_Specialty_v1.indd   82

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-83

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products  - Patch Panels

ORDERING INFORMATION

Cover for Angled Patch Panels

FEATURES

• 

For use with angled patch panels

• 

Protects cabling from dust and damage

Description

Part Number

Cover for Angled Patch Panels

 1499614-1

Figure A

Port Count

Height

Width

Figure

Part Number

24

1RU (1.75")

19.0"

A

 1479449-1

48

2RU (3.50")

19.0"

 1479450-1

ORDERING INFORMATION

Multimedia Integrated Cable Management SL Series Patch Panels

FEATURES

• 

Accept unshielded SL Series Jacks and inserts

• 

May be used to create custom confi gurations – including
mixing fi ber, twisted-pair, coax and A/V applications

• 

Allow elimination of horizontal cable management for
higher rack densities and ease of cable dress

• 

Ports may be individually replaced

• 

Replacement labels and clear label covers are available

 Discrete High-Density Angled SL Series Patch Panel

FEATURES

• 

Accepts AMP-TWIST, shielded, and unshielded SL Series Jacks and
inserts (purchased separately)

• 

Highest density solution for 2RU (3.50")

• 

Ports may be individually replaced

• 

Angled version allow elimination of horizontal cable management for
higher rack densities and ease of cable dress

ORDERING INFORMATION

Description

Height

Width

Part Number

72-Port Discrete Angled Panel

2RU (3.50")

19.0"

 1499613-1

Description

Figure

1U [1.75"]

2U [3.50"]

3U [5.25"]

4U [7.00"]

5U [8.75"]

Standard

A

 556965-1

 556965-2

 556965-3

 556965-4

 556965-5

Angled

B

 1479992-1

 1479992-2

Sc3_Copper_05_Specialty_v1.indd   83

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-84

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products  - Patch Panels

110Connect Modular Jack Patch Panels
 

FEATURES

• 

Shielded patch panels accept shielded 110Connect and Inserts
for 110Connect modular jack patch panels

• 

Unshielded patch panels accept unshielded 110Connect and
Inserts for 110Connect modular jack patch panels

• 

May be used to create custom configurations

• 

Ports may be individually replaced

Figure A

Unshielded

Figure A 

Shielded

ORDERING INFORMATION

Part Number

Port Count

Height

Width

Figure

Unshielded

Shielded

16

1RU (1.75")

19.0"

A

557429-1

557429-2

NOTE: Shielded patch panels use grounding lug kit 556438-1 for isolated grounding

Sc3_Copper_05_Specialty_v1.indd   84

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-85

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products  - Patch Panels

Figure A

Figure B

ORDERING INFORMATION

Part Number

Description

Figure

Almond

Black

Blank

A

558856-2

558856-1

F-Connector Coupler

B

558862-2

558862-1

NOTE: Not compatible with standard or angled faceplates or office boxes.

Inserts for 110Connect Modular Jack Patch Panels  
 

FEATURES

• 

Used with 110Connect modular jack patch panels

• 

Inserts also work with standard, 0.582" x 0.762" openings

Description

Part Number

1RU Rack Mount Fiber Optic Patch Panel 

1777125-1

1RU Rack Mount Fiber Optic Patch Panel
 

FEATURES

• 

Accepts three (3) snap-in adapter plates or MPO cassettes
(sold separately)

• 

Fits standard TIA 19 inch rack

• 

1RU (1.75")

ORDERING INFORMATION

Sc3_Copper_05_Specialty_v1.indd   85

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-86

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Jacks and Couplers

SL Series Category 3 Modular Jacks
 

FEATURES

• 

Thin profile improves outlet density

• 

180° or 90° cable dress for easy termination

• 

UL Listed: E81956

• 

Unshielded, 6-Position RJ11c/RJ14c/RJ25c modular jacks for 1, 2 and 3-Pair applications

• 

Can be terminated with either SL series modular jack termination
tool (1725150-1) or standard 110 punch-down tools

• 

RoHS compliant

ORDERING INFORMATION

Part Number

Color

Without Dust Cover

Almond

1375192-1

Black

1375192-2

Gray

1375192-4

Blue

1375192-6

Alpine White

1-1375192-3

Note: Colors are approximate and for reference only.

Keystone Category 3 Modular Couplers
 

FEATURES

• 

Compact couplers for two modular plugs

• 

Couplers snap into 0.585" x 0.765" rectangular faceplate cutouts

• 

Wired one-to-one

Description

Number of Positions

Figure

Part Number

Right-Angle Coupler

6

A

555049-1

8

555051-1

8 (Keyed)

555377-1

In-Line Coupler

6

555050-1

8

B

555052-1

8 (Keyed)

555376-1

6 (MMJ/MMJ)

556625-1

6 (MMJ/STD)

556627-1

ORDERING INFORMATION

Figure A

Right-Angle Coupler 

Figure B

In-Line Coupler

Sc3_Copper_05_Specialty_v1.indd   86

12/14/12   2:24 PM

Tyco-catalog-AMP-2013-html.html
background image

3-87

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Jacks and Couplers

SL Series Modular Jack Strain Relief

• 

Provide strain relief for terminated cables in the work area

• 

Strain reliefs are for use with unshielded SL series modular jacks only

ORDERING INFORMATION

Description

Color

Figure

Part Number

Bend-Limiting Strain Relief

Smoked Gray

A

 1375200-1

Strain Relief

Clear

B

 1375157-1

Figure B

Figure A

RJ45 Dust Cover

FEATURES

• 

RJ45 Dust Covers:

Protect contacts from dust, build-up and contaminants which can
aff ect performance

Work with any RJ45 jack

Made of fl exible plastic for snug fi t and contact protection

Tab makes installation and removal a snap

EU RoHS/ELV compliant

ORDERING INFORMATION

Description

Color

Figure

Part Number

RJ45 Dust Cover

Black

A

 2111285-2

Figure A

Sc3_Copper_05_Specialty_v1.indd   87

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-88

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Modular plugs

8-Position,

Round, Standard

6-Position,

Round, Standard

6-Position,

Round, Long

6-Position,

Flat, Standard

8-Position,

Flat, Standard

Shielded 8-Position

Round, Standard

Category 3 Modular Plugs

FEATURES

• 

Accommodate conductors as listed

• 

RoHS compliant

• 

Molded with UL94V-0 rated plastic

• 

UL Listed: E81956

• 

For termination tooling, see page 3-120

• 

Modular plug to die set cross reference on page 3-120

• 

Refer to Category 5e products on page 3-43 for
Modular Plug Boots and External Strain Reliefs

Positions Shielding

Keying

Cable 

Type

Cable Jacket

O.D.

Conductor 

Type

AWG

Insulation O.D.

Body 

Type

Quantity 

Per Box

Part 
Number

6

Unshielded

Unkeyed

Round

0.180" 

(4.58 mm) max.

Stranded

28-26

0.035" (0.89 mm) max. 

Standard

100*

 5-554710-3

28-26

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Long

100*

 5-555177-3

0.195" 

(4.96 mm) max.

Solid

26-24

0.039" (0.99 mm) max.

Long

100*

 5-555426-3

Flat 

Oval

0.090" x 0.260"

 (2.29 mm x 6.61 mm) 

max.

Stranded

28-26

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Standard

100*

 5-641337-3

Solid

26-24

0.035" to 0.039" 

(0.89 mm to 0.99 mm)

Standard

100*

 5-555042-3

Shielded

Unkeyed

Flat 

Oval

0.110" x 0.270" 

(2.79 mm x 6.85 mm) 

max.

Stranded

28-26

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Long

500

 5-555174-2

Round

0.180" 

(4.58 mm) max.

Stranded

28-26

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Long

100*

 5-555175-3

8

Unshielded

Keyed

Round

0.210" (5.33 mm) max.

Stranded

28-26

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Standard

100*

 5-554170-3

Unkeyed

Round

0.210" (5.33 mm) max.

Stranded

28-26

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Standard

100*

 5-554169-3

0.200" (5.08 mm)

Solid

26-24

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Long

100*

 5-557315-3

Flat 

Oval

0.100" x 0.350" 

(2.54 mm x 8.89 mm) 

max.

Stranded

28-26

0.035" to 0.039" 

(0.89 mm to 0.99 mm)

Long

100*

 5-554739-3

Solid

26-24

0.035" to 0.039" 

(0.89 mm to 0.99 mm)

Standard

100*

 5-554720-3

Shielded

Unkeyed

Round

0.200" (5.08 mm)

Stranded

28-24

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Standard

100

 5-569532-3

Solid

26-24

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Standard

100

 5-569530-3

Flat 

Oval

0.110" x 0.355" 

(2.79 mm x 9.02 mm) 

max.

Stranded

28-24

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Standard

100

 5-569542-3

* Note: 10 boxes per carton

ORDERING INFORMATION

Sc3_Copper_05_Specialty_v1.indd   88

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-89

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Feed-Thru Termination Block System and Accessories

1. Terminate cables

2. Move base unit from

bottom to top

3. Flip and snap into place

FEATURES

• 

Appropriate for both data and voice application

• 

High-density and quick installation are the hallmarks of the 25-pair Feed-Thru
(FT) block system

• 

The 25-pair FT block is the perfect replacement for 110 installations

• 

Complete patching and cross-connect options provide the versatility required
for any configuration

• 

Color-coded blocks are offered, with each pair color marked according to
industry standards

• 

Handy label holders provide clear identification of groups or individual pairs

Feed-Thru Termination Block System and Accessories

The FT field assembly kits feature the universal mounting system, which provides
modularity and three mounting options:

• 

Wall mount

• 

Wall mount with optional UMS backboard for greater cabling depth

• 

Rack mount with UMS backboard

FT field assembly kits include a universal mounting bracket, two horizontal wire
managers and a choice of 4-pair or 5-pair color-coded FT blocks. Route cable
from the top, bottom or rear. Four-pair color-coded blocks are marked with TIA
color codes in 4-pair groups. Five-pair coded blocks are marked with a white
stripe on every fifth pair. Labeling accessories, such as label holders and paper
labels, are sold separately.

Positions Shielding

Keying

Cable 

Type

Cable Jacket 

O.D.

Conductor 

Type

AWG

Insulation O.D.

Body 

Type

Quantity 

Per Box

Part 
Number

6

Unshielded

Unkeyed

Round

0.180" 

(4.58 mm) max.

Stranded

28-26

0.035" (0.89 mm) max. 

Standard

100*

5-554710-3

28-26

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Long

100*

5-555177-3

0.195" 

(4.96 mm) max.

Solid

26-24

0.039" (0.99 mm) max.

Long

100*

5-555426-3

Flat 

Oval

0.090" x 0.260"

 (2.29 mm x 6.61 mm) 

max.

Stranded

28-26

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Standard

100*

5-641337-3

Solid

26-24

0.035" to 0.039" 

(0.89 mm to 0.99 mm)

Standard

100*

5-555042-3

Shielded

Unkeyed

Flat 

Oval

0.110" x 0.270" 

(2.79 mm x 6.85 mm) 

max.

Stranded

28-26

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Long

500

5-555174-2

Round

0.180" 

(4.58 mm) max.

Stranded

28-26

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Long

100*

5-555175-3

8

Unshielded

Keyed

Round

0.210" (5.33 mm) max.

Stranded

28-26

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Standard

100*

5-554170-3

Unkeyed

Round

0.210" (5.33 mm) max.

Stranded

28-26

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Standard

100*

5-554169-3

0.200" (5.08 mm)

Solid

26-24

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Long

100*

5-557315-3

Flat 

Oval

0.100" x 0.350" 

(2.54 mm x 8.89 mm) 

max.

Stranded

28-26

0.035" to 0.039" 

(0.89 mm to 0.99 mm)

Long

100*

5-554739-3

Solid

26-24

0.035" to 0.039" 

(0.89 mm to 0.99 mm)

Standard

100*

5-554720-3

Shielded

Unkeyed

Round

0.200" (5.08 mm)

Stranded

28-24

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Standard

100

5-569532-3

Solid

26-24

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Standard

100

5-569530-3

Flat 

Oval

0.110" x 0.355" 

(2.79 mm x 9.02 mm) 

max.

Stranded

28-24

0.029" to 0.039" 

(0.74 mm to 0.99 mm)

Standard

100

5-569542-3

* Note: 10 boxes per carton

Sc3_Copper_05_Specialty_v1.indd   89

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-90

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Feed-Thru Termination Block System and Accessories

Feed-Thru (FT) Termination Block Systems

Front 

Blue

Back 

White

Type 160 Hinged

Description

Dimensions (HxWxD)

Part Number

25-pair FT block       

Quantity: 1

4-pair color-coded 

Allows high-density termination in small area; 
two-piece assembly, consisting of base and 
connector. 4-pair color-code marked on face 
of block. Used for terminating 4-pair  
station cables; each block terminates  
(6) 4-pair cables

1" x 8.75" x 1.88"  

(25.4 mm x 225.3 mm x 47.6 mm)

6631 2 135-05

5-pair color-coded

Allows high-density termination in small area; 
two-piece assembly, consisting of base and 
connector. 5-pair color-code (blue, orange, 
green, brown, slate) marked on face of 
block. Used for terminating 25-pair cable

1" x 8.75" x 1.88"  

(25.4 mm x 225.3 mm x 47.6 mm)

6631 2 135-06

5-pair code

Allows high-density termination in small area; 
two-piece assembly, consisting of base and 
connector. Marked in white every fifth pair. 
Used for terminating riser cables or with PBX 
systems. Each block terminates 25-pair

1" x 8.75" x 1.88"  

(25.4 mm x 225.3 mm x 47.6 mm)

6631 2 135-00

Type 160 hinged label holder

Used on 25-pair FT block to identify cable 
groups or individual pairs; folds out of the 
way when punching down wires; can be used 
for 1- to 25-pair configurations 
Quantity: 1

6631 2 003-00

Label sheets for Type 160 hinged label holder

Each 8.5" x 11" sheet contains 34 perforated  
labels  Quantity: 1 sheet per package

Blue and white

One side is blue and marked in 4-pair 
increments; other side is white and 
marked in 5-pair increments

6631 3 100-26

Gray/brown

6631 3 100-22

Yellow/red

6631 3 100-23

Orange

6631 3 100-27

Purple

6631 3 100-28

Blue

6631 3 100-29

Green

6631 3 100-30

ORDERING INFORMATION

Sc3_Copper_05_Specialty_v1.indd   90

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-91

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Feed-Thru Termination Block System and Accessories

Description

Dimensions (HxWxD)

Part Number

100-pair, 4-pair color-coded kit 

Includes (4) 25-pair FT blocks with 4-pair color-coding, 
2 horizontal wire managers, 1 universal mounting bracket. 
Terminates (24) 4-pair station cables. Hinged label holders 
for identification of stations or pairs ordered separately

14.75" x 10.75" x 5.25" 

(374.7 mm x 273.1 mm x 133.4 mm) 

6642 1 115-04

100-pair, 5-pair color-coded kit 

Includes (4) 25-pair FT blocks with 5-pair code 
marked on face of block, 2 horizontal wire managers, 
1 universal mounting bracket. Hinged label holder for 
identification of stations or pairs ordered separately

14.75" x 10.75" x 5.25" 

(374.7 mm x 273.1 mm x 133.4 mm) 

6642 1 115-05 

300-pair, 4-pair color-coded kit

Includes (12) 25-pair FT blocks with 4-pair color-coding, 
2 horizontal wire managers, 1 universal mounting bracket. 
Terminates (72) 4-pair station cables. Hinged label holder 
for identification of stations or pairs ordered separately

14.75"  x 10.75" x 5.25" 

(374.7 mm x 273.1 mm x 133.4 mm)

6642 1 315-04 

300-pair, 5-pair color-coded kit

Includes (12) 25-pair FT blocks with 5-pair code 
marked on face of block, 2 horizontal wire managers, 
1 universal mounting bracket. Hinged label holder for 
identification of stations or pairs ordered separately

14.75" x 10.75" x 5.25" 

(374.7 mm x 273.1 mm x 133.4 mm)

6642 1 315-05

Feed-Thru (FT) Field Assembly Kits

ORDERING INFORMATION

Sc3_Copper_05_Specialty_v1.indd   91

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-92

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Feed-Thru Termination Block System and Accessories

Patch Cords for Feed-Thru (FT) 

These FT patch cords use TE Category 5e cable and exceed the 
requirements for Category 5e.

*Replace XX with:  04 = 4'
 

07 = 7'

 

10 = 10'

 

15 = 15'

 

25 = 25'

 

50 = 50'

Pair No.

Pair 4

R

T

Pair 3

R

T

Pair 2

R

T

Pair 1

R

T

Wired  
to Pin #

Pair No.

8
7

Pair 4

R

T

2
1

Pair 3

R

T

6
3

Pair 2

R

T

4
5

Pair 1

R

T

Description

Cable Color

Part Number*

4-pair FT plug to FT plug, 

wired straight through  Quantity: 1

White

TP5ETF-WT

XX

Red

TP5ETF-RD

XX

Blue

TP5ETF-BL

XX

Green

TP5ETF-GN

XX

Yellow

TP5ETF-YL

XX

Gray

TP5ETF-GY

XX

4-pair FT plug to RJ45 (8P8C) plug, 

wired T568A  Quantity: 1

White

TP5ETB0WT

XX

Red

TP5ETB0RD

XX

Blue

TP5ETB0BL

XX

Green

TP5ETB0GN

XX

Yellow

TP5ETB0YL

XX

Gray

TP5ETB0GY

XX

ORDERING INFORMATION

Sc3_Copper_05_Specialty_v1.indd   92

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-93

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products - Feed-Thru Termination Block System and Accessories

*Replace XX with:  04 = 4' 

15 = 15'

 

07 = 7' 

25 = 25'

 

10 = 10' 

50 = 50'

 

Pair No.

Pair 1

R

T

Wired  
to Pin #

Pair No.

8
7

Pair 4

R

T

6
3

Pair 3

R

T

2
1

Pair 2

R

T

4
5

Pair 1

R

T

Description

Cable Color

Part Number*

4-pair FT plug to RJ45 (8P8C) plug, 

wired T568B  Quantity: 1

White

TP5ETB-WT

XX

Red

TP5ETB-RD

XX

Blue

TP5ETB-BL

XX

Green

TP5ETB-GN

XX

Yellow

TP5ETB-YL

XX

1-pair FT plug to FT plug, 

wired straight through  Quantity: 1

White

6645 2 251-

XX

Red

6645 2 264-

XX

Blue

6645 2 265-

XX

2-pair FT plug to FT plug, 

wired straight through   Quantity: 1

White

6645 2 266-

XX

Red

6645 2 267-

XX

Blue

6645 2 268-

XX

Pair No.

Pair 2

R

T

Pair 1

R

T

ORDERING INFORMATION

Patch Cords for Feed-Thru (FT) Blocks

Feed Thru (FT) Block Test Cord

Description

Part Number

FT block test cord

1-pair FT connector to 2 banana plugs (connect to test equipment), 1' length.  
Used to bridge or monitor circuit  Quantity: 1

6645 2 254-01

ORDERING INFORMATION

FT test cord

Sc3_Copper_05_Specialty_v1.indd   93

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-94

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Zone Cabling Solutions

Mini Multi-User Outlet (MUO)

FEATURES

• 

Provides a 6-port outlet particularly suited to open office or
laboratory environments

• 

May be used free-hanging or mounted

• 

Available in Category 5e and Category 6 performance

• 

Meets TIA and ISO performance requirements

• 

Universal wiring – one part number may be terminated to T568A or T568B

• 

Suitable for use with either 4-pair or 25-pair cable

• 

Kits include housing, connector module and heat shrink tubing

Description

Part Number

Category 5e, 6-Port Mini MUO

1479144-1

Category 6, 6-Port Mini MUO

1375376-1

Category 5e, 6-Port MUO with Dust Cover Jacks

1933084-1

Category 6, 6-Port MUO with Dust Cover Jacks

1933085-1

ORDERING INFORMATION

Sc3_Copper_05_Specialty_v1.indd   94

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-95

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Zone Cabling Solutions

ORDERING INFORMATION

Figure A

Figure B

Figure C

FEATURES

• 

Designed for use in 2' x 2' raised fl oor systems

• 

Accommodate standard 19-inch patch panels and/
or cable management panels as listed

• 

Consolidation points for 2.5" high raised fl oor
systems are designed to fi t low profi le raised fl oors

• 

Consolidation points for 10" high raised fl oor
systems are intended for high density applications
in data centers, server rooms, etc.

• 

Consolidation points for 6"– 10" high raised fl oor
systems feature hinged patch panel mounts which
allow easy access to patch panels for moves adds
and changes

• 

Complies with NEC 300-22(c) requirements for use in
environmental air spaces

• 

Allows moves, adds and changes without
re-terminating and re-testing cable

• 

Forms an interconnect between work area cabling
and horizontal feeder cables

• 

Complies with TIA/EIA-568-C and
ISO 11801:2002 requirements

• 

Fiber Support Bar accepts Fiber Snap-in Adapter
Plates or MPO Cassettes

• 

Security consolidation point includes lockable cover
and fi ts under fl oor tiles allowing access from a
single tile

Description

For Use WIth

Total Capacity

Figure

Part Number

Consolidation Points for Raised Floors

2.5" Raised Floors

2RU (1RU + 1RU)

 1479158-1

4" Raised Floors

2RU or Angled MRJ21 Patch Panels

 1479956-1

6" Raised Floors

4RU (2RU + 2RU)

A

 1479042-1

7" Raised Floors

8RU (4RU + 4RU)

B

 1479359-1

10" Raised Floors

12RU (6RU + 6RU)

C

 1479360-1

Security Consolidation Point for Raised Floors
(drop in box with lock)

8" Raised Floors

8RU (4RU + 4RU)

D

 1479297-1

Fiber Support Bar Kit

1479359,1479360, 

1479040, and 1479297

12 Adapter Plates or

MPO Cassettes

E

 1479326-1

Figure D

Figure E

Forward Position

Installed

Consolidation Points for Raised Floor Systems

Sc3_Copper_05_Specialty_v1.indd   95

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-96

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Zone Cabling Solutions

ORDERING INFORMATION

Description

Total Capacity

Figure

Part Number

Passive Consolidation Points

5RU (2RU+1RU+2RU) for Passive Equipment

A

1479040-1

Two 300-Pair Cross-Connect Blocks Without Legs

B

1479041-1

Active Consolidation Point

5RU (2RU+1RU+2RU) for Passive equipment, 

2RU (2RU) for Active equipment

C

1479039-1

Consolidation Points for Drop Ceiling Systems
 

FEATURES

• 

Designed for use in 2' x 2' ceiling tile grid systems

• 

Passive consolidation points accommodate standard 19-inch patch
panels, cable management panels or 300-Pair cross-connects
as listed

• 

Active consolidation points accommodate 2RU of active LAN
equipment in addition to same passive components as the passive
consolidation point 1479040

• 

Complies with NEC 300-22(c) requirements for use in environmental
air spaces

• 

Allows moves, adds and changes without re-terminating and
re-testing cable

• 

Forms an interconnect between work area cabling and horizontal
feeder cables

• 

Complies with TIA/EIA-568-C and ISO 11801:2002 requirements

Figure A

Figure B

Figure C

Sc3_Copper_05_Specialty_v1.indd   96

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-97

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Zone Cabling Solutions

Figure A

Figure B

Figure C

Modular Consolidation Point Modules
 

FEATURES

• 

Comply with TIA/EIA-568-C and ISO 11801 requirements

• 

Multimedia module accepts up to six SL series jacks,
MT-RJ outlet jacks or SL Series inserts enabling custom configurations

• 

SL Series Modules feature individually replaceable ports

• 

MT-RJ module holds up to six MT-RJ patch panel jacks (sold separately)

• 

SC Modules suitable for multimode connectors

ORDERING INFORMATION

Description

Port Count

Figure

Part Number

Modular Consolidation  
Point Modules

Category 6 (Jacks Included)

6-Port

A

1375367-1

Category 5e (Jacks Included)

6-Port

406772-1

Multimedia, Unshielded (Connectivity Not Included)

6-Port

1479696-1

Multimedia, Shielded (Connectivity Not Included)

6-Port

1933895-1

MT-RJ (MT-RJ Patch Panel Jacks Not Included)

6-Ports/12-Fibers

B

1375093-1

SC Duplex (Includes Couplers)

6-Ports/12-Fibers

C

406788-1

MPO Cassette and Fiber Insert

1479142-1

ORDERING INFORMATION

Modular and Cross-Connect Consolidation Points

FEATURES

• 

Designed for use in both raised floor and drop ceiling systems

• 

Allows moves, adds and changes without re-terminating and retesting cable

• 

Forms an interconnect between work area cabling and horizontal feeder cables

• 

Complies with TIA/EIA-568-C and ISO 11801 requirements

• 

Cross-connect consolidation points accommodate two
100-Pair 110Connect XC wiring blocks without legs

• 

24-Port modular consolidation points accommodate four connector modules

• 

48-port modular consolidation points accommodate eight connector modules

• 

Complies with NEC 300-22 (c) requirements for use in environmental air spaces

• 

Compliant with UL 2043 for use in environmental air spaces

• 

UL listed: file number E81956

Figure A

Figure B

Description

Maximum Capacity

Accommodates

Figure

Part Number

Modular Consolidation Points

24-Port

Four Consolidation Point Modules

A

406771-1

48-Port

Six Consolidation Point Modules

1479322-1

Cross-connect Consolidation Point

200-Pair

Two 100-Pair 110Connect XC Wiring Blocks

B

406771-2

Sc3_Copper_05_Specialty_v1.indd   97

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-98

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Zone Cabling Solutions

ORDERING INFORMATION

Consolidation Point Transition Cable Assemblies

FEATURES

• 

Form connections between work area and consolidation point

• 

Factory-assembled and tested

• 

Save time and money on moves, adds and changes

• 

Lead-Free (no heavy metals)

• 

Gray Cable Jacket

• 

Category 6 and 6A cable assemblies require jacks to be ordered and
terminated separately

Part Number

End A

End B

Figure Length

Riser (CMR) T568A

Riser (CMR) T568B

Plenum (CMP) T568A

Plenum (CMP) T568B

Category 6A 
Shielded
Modular Plug

Un-terminated

40'

 4-1933920-0

 4-1933921-0

 4-1499783-0

 4-1933335-0

50'

 5-1933920-0

 5-1933921-0

 5-1499783-0

 5-1933335-0

60'

 6-1933920-0

 6-1933921-0

 6-1499783-0

 6-1933335-0

70'

 7-1933920-0

 7-1933921-0

 7-1499783-0

 7-1933335-0

80'

 8-1933920-0

 8-1933921-0

 8-1499783-0

 8-1933335-0

90'

 9-1933920-0

 9-1933921-0

 9-1499783-0

 9-1933335-0

Category 6
Modular Plug

Un-terminated

20'

 1499056-1

 1499056-5

 1499057-1

 1499057-5

30'

 1499056-2

 1499056-6

 1499057-2

 1499057-6

40'

 1499056-3

 1499056-7

 1499057-3

 1499057-7

50'

 1499056-4

 1499056-8

 1499057-4

 1499057-8

Category 5e
Modular Plug

SL Series
Category 5e
Modular Jack

A

20'

 219172-1

 219173-1

 219174-1

 219175-1

30'

 219172-2

 219173-2

 219174-2

 219175-2

40'

 219172-3

 219173-3

 219174-3

 219175-3

50'

 219172-4

 219173-4

 219174-4

 219175-4

Figure A

Sc3_Copper_05_Specialty_v1.indd   98

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-99

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Zone Cabling Solutions

ORDERING INFORMATION

ORDERING INFORMATION

50/125

µ

m OM1 Multimode MT-RJ Transition Point Cable Assemblies

FEATURES

• 

Form connections between work area and consolidation point

• 

Factory-assembled and tested

• 

Save time and money on moves, adds and changes

• 

Riser (OFNR) rated

• 

Orange jacketing

Part Number

Connector

Length

End 1

End 2

10'

20'

30'

40'

50'

MT-RJ Plug

MT-RJ Jack (with Right Angle Boot)

 6457240-1

 6457240-2

 6457240-3

 6457240-4

 6457240-5

• 

Very low profi le

• 

Supports a single adapter plate, MRJ21
cassette, or MPO cassette

• 

Gasketed entry to reduce dust intrusion

• 

Separate mounting/strain relief plate

• 

Not plenum rated

• 

Captive fasteners

• 

Economical

• 

Can be magnet mounted

• 

Robust construction

• 

Tamper resistant version available

• 

Internal bonding lug

• 

Nominal dimensions: 1.75”(4.5 cm) H x
11” (28 cm) D x 5.4” (14 cm) W

Easy Access Zone (EAZ) Enclosure

FEATURES

Figure A

 Figure B

Description

 

Figure

Part Number

Easy Access Zone Enclosure

with Phillips Head 1/4 Turn Fasteners

A

 1777215-1

with Tamper-proof Cover Fasteners

 1777215-2

Strain Relief Bracket for Easy Access Zone Enclosure

B

 1777224-1

Part Number

End A

End B

Figure Length

Riser (CMR) T568A

Riser (CMR) T568B

Plenum (CMP) T568A

Plenum (CMP) T568B

Category 6A 
Shielded
Modular Plug

Un-terminated

40'

 4-1933920-0

 4-1933921-0

 4-1499783-0

 4-1933335-0

50'

 5-1933920-0

 5-1933921-0

 5-1499783-0

 5-1933335-0

60'

 6-1933920-0

 6-1933921-0

 6-1499783-0

 6-1933335-0

70'

 7-1933920-0

 7-1933921-0

 7-1499783-0

 7-1933335-0

80'

 8-1933920-0

 8-1933921-0

 8-1499783-0

 8-1933335-0

90'

 9-1933920-0

 9-1933921-0

 9-1499783-0

 9-1933335-0

Category 6
Modular Plug

Un-terminated

20'

 1499056-1

 1499056-5

 1499057-1

 1499057-5

30'

 1499056-2

 1499056-6

 1499057-2

 1499057-6

40'

 1499056-3

 1499056-7

 1499057-3

 1499057-7

50'

 1499056-4

 1499056-8

 1499057-4

 1499057-8

Category 5e
Modular Plug

SL Series
Category 5e
Modular Jack

A

20'

 219172-1

 219173-1

 219174-1

 219175-1

30'

 219172-2

 219173-2

 219174-2

 219175-2

40'

 219172-3

 219173-3

 219174-3

 219175-3

50'

 219172-4

 219173-4

 219174-4

 219175-4

Sc3_Copper_05_Specialty_v1.indd   99

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

3-100

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Specialty Products – Zone Cabling Solutions

ORDERING INFORMATION

Wall/Furniture Mounting Bracket

FEATURES

• 

Options to accept up to two snap-in adapter plates, MPO, MRJ21 cassettes
(sold separately)

• 

Mounting holes for fastening to TIA rack, wall, or furniture

• 

Bracket color: black

• 

Compatible with magnetic mounts

• 

Optional cable management ring is not compatible with cassettes

Shown with optional cable ring

Description

Part Number

Wall/Furniture Mounting Bracket for snap-in adapter plates and MPO Cassettes

1777126-1

Optional Cable Management Ring

1206146-1

Wall/Furniture Mount Bracket for MRJ21 Cassettes

1933981-1

Sc3_Copper_05_Specialty_v1.indd   100

12/11/12   4:15 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-101

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Accessories

ORDERING INFORMATION

Velcro Cable Ties
 

FEATURES

For 8-inch and 12-inch ties, an order quantity of one equals one roll of ten ties.

Part Number

Description

Figure

Black

Blue

1" x 8"

A

1375253-2

1" x 12"

B

1375254-2

5/8" x 5 yards

C

1375255-2

1375255-6

1" x 12" Flame Retardant*

1375256-2

* NOTE:  Complies with NEC 300-22(c) and (d) for use in environmental air handling spaces.  

Available in black only.

Dimensions (Approximate)

Minimum Tensile 

Strength

Maximum Bundle 

Diameter

Package 

Quantity

Part Number

Length

Width

Thickness

Natural

Black

4" (103.0 mm)

0.096"  

(2.44 mm)

0.037" 

 (0.94 mm)

18 lbs  

(80.1 N)

0.75" 

 (19.10 mm)

1000

2-604771-9

2-604771-0

100

1-604771-9

1-604771-0

6" (155.0 mm)

0.140"  

(3.56 mm)

0.045"  

(1.14 mm)

30 lbs  

(133.5 N)

1.25"  

(31.75 mm)

1000

2-603227-9

2-603227-0

100

1-603227-9

1-603227-0

8" (204.0 mm)

0.184"  

(4.67 mm)

0.047"  

(1.19 mm)

50 lbs (222.5 N)

1.75" 

 (44.45 mm)

1000

2-604772-9

2-604772-0

100

1-604772-9

1-604772-0

12" (300.0 mm)

0.183" 

 (4.65 mm)

0.051" 

 (1.30 mm)

50 lbs (222.5 N)

3.00"  

(76.20 mm)

1000

2-604751-9

2-604751-0

100

1-604751-9

1-604751-0

AMP-TY Nylon Cable Ties

ORDERING INFORMATION

Figure A

Figure C

Figure B

Sc3_Copper_06_Accessories_v1.indd   101

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-102

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

Icon Wheels

• 

SL series modules

• 

SL series furniture outlets 

• 

SL series mounting straps

• 

Modular jack boxes

• 

Faceplates

• 

Surface mount modules

• 

HideAway outlet

• 

HideOut outlet

• 

Iconable ACO faceplates

• 

FLEX-MODE faceplates

• 

MT-RJ rack mount enclosure

• 

MT-RJ snap-in adapter plate

• 

SL series Category 5E and 6 patch panels

• 

110Connect Category 5 and 5e patch panels

• 

 SL series multimedia jack patch panels

• 

Iconable ACO patch panels

Each Wheel Contains:

Part Number

Da

ta

Blank

P

hone

Fa

x

Modem P

rint

Ca

5

Ca

5e

Ca

6

Ca

6A

V1 V2 D1 D2 Almond Red

Green

Blue

Yellow

Black

Orange

White

Violet

Gray

Electrical 
Ivory

1 4 1 – – – – 2 2 2 1 1 1 1

1375092-1 1375092-2 1375092-3 1375092-4 1375092-5 1375092-6 1375092-7 1375092-8 1375092-9 1-1375092-0 1-1375092-1

16 – – – – – – – –

– – – –

558198-1

558198-2 558198-3 558198-4

558198-5

558198-6

558198-7

558198-8

558198-9

1-558198-0 1-558198-1

– – 16 – – – – – –

– – – –

558199-1

558199-2 558199-3 558199-4

558199-5

558199-6

558199-7

558199-8

558199-9

1-558199-0 1-558199-1

– 16 – – – – – – –

– – – –

558821-1

558821-6

558821-8

1-558821-0 1-558821-1

FEATURES

Used with the following products:

Sc3_Copper_06_Accessories_v1.indd   102

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-103

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Accessories

TE Connectivity is partnered with Silver Fox utilizing labeling 
software, label sheets and templates to meet todays labeling 
needs. Select from perforated card stock or pre-cut self-adhesive 
polyester label sheets which can be used with various style 
printers. The standard free verson is ideal for small simple jobs or 
upgrade to the advance version which offers enhanced features 
for complex builds. A varity of accessories and labels are also 
offered to support Type 105 mounting applications. 

Visit www.te.com/labeling to download a free trial copy or to 
order software from Silver Fox, Ltd.

Identification Labels and Accessories

Standard Free Trial
 

FEATURES

• 

Create simple builds

• 

Copy and paste information directly from 
spreadsheets or other applications

• 

Change font style

• 

Integrated tutorials

• 

Integrated context sensitive help 

• 

Limited to 5 pages printing per job 

• 

Download free of charge from our website

Advanced Purchased License
 

FEATURES

• 

Create simple builds

• 

Copy and paste information directly from 
spreadsheets or other applications

• 

Change font style

• 

Integrated tutorials

• 

Integrated context sensitive help

• 

No limit to printing pages per job

• 

Create complex builds

• 

Change font size

• 

Multiple builds

• 

Split labels

• 

Repeat previous build

• 

Import multiple column csv spreadsheet files

• 

Select start line for printing

• 

Save and open jobs

• 

Job notes facility

• 

Add symbols

• 

Change text alignment

• 

Change viewing scale

• 

Copy job from label type to another

• 

Print job notes

• 

Print page number and date

• 

Automatic web update facility*

• 

Purchase from our website eShop 

• 

A trial of the advanced version is included 
with the standard version

*internet connection required

The templates browser has photographs which allows users to quickly and easily identify 
which products they need to label and the software will automatically load up the correct 
template for their application.

Photo-based Browser

The templates browser has photographs which allows users to quickly and easily identify 
which products they need to label and the software will automatically load up the correct 
template for their application.

Photo-based Browser

All versions are delivered via wed download. Disks are available on request from our sales team. Please note that there will be an extra charge for 
this service. Multiple-user licenses are available direct from our sales team – contact us for details.

Sc3_Copper_06_Accessories_v1.indd   103

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-104

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

AMP NETCONNECT Labeling Software

FEATURES

• 

Compatible with 32 or 64-bit versions of Microsoft Windows 2000, NT, XP, Vista or 7 operating systems

• 

Flexible build option to produce more complex alphanumeric identifi ers

• 

Create identifi ers consisting of up to 12 independent segments

• 

Can cope easily with the TIA/EIA-606-A standard identifi cation sequences

• 

Insert symbols (all standard Windows symbols can be used)

• 

Save and edit builds

• 

Fine tune adjustment

• 

Split your label format as required

• 

Job notepad facility for builds saved to fi le

• 

Justify text

• 

Adjust font style and size

• 

Context-sensitive help

Visit www.te.com/labeling to download a free trial copy or to order software from Silver Fox, Ltd.

Standard Labels for Outlets

FEATURES

• 

Labels are designed to fi t TE Connectivity faceplates and outlets
(Reference compatibility list for correct label/out compatibility)

• 

Card stock labels are perforated and compatible with inkjet and laser printers

• 

Self-adhesive polyester labels are pre-cut and compatible with laser printers

• 

Labels are supplied on 8.5" x 11" sheets

• 

For use with:

SL series faceplates

HideAway multimedia outlet

Wiremold raceway faceplates

Universal offi ce box, 6-port

Multimedia security outlet

ACO faceplates

Part Number

Description

Label Size (W x H)

Labels per Sheet

Figure

5 Sheets

100 Sheets

Card Stock

1.98" x 0.373"

72

A

1375356-1

5-1375356-1

Self-adhesive Polyester

1.98" x 0.373"

72

A

1375357-1

5-1375357-1

Card Stock

1.88" x .600"

45

B

2111415-1

5-2111415-1

Self-adhesive Polyester

1.88" x .600"

45

B

2111416-1

5-2111416-1

ORDERING INFORMATION

Figure A

Figure B

WIREMOLD is a trademark.

Sc3_Copper_06_Accessories_v1.indd   104

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-105

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

ORDERING INFORMATION

Description

Color

Part Number

Label Cover

Transparent

1375345-1

Label Covers for Faceplates
 

FEATURES

• 

Kit includes fifty die-cut labels and clear plastic covers

• 

For use in SL series, angled, iconable ACO, and Wiremold compatible faceplates

Universal Labels

TE's AMP NETCONNECT labeling software allows customization of the
universal labels listed for use with multiple products.

Description

Application

Labels per Sheet

Labels per Package

Part Number

5 Sheets

100 Sheets

5 Sheets

100 Sheets

Self-adhesive Polyester

Modular Jack Box, 1-Port 

216

1,080

21,600

1375358-1

5-1375358-1

Modular Jack Box, 2-Port  

120

600

12,000

1375358-1

5-1375358-1

SL Series Furniture Outlet  

72

360

7,200 

1375358-1

5-1375358-1

SL Series Faceplate, Double Gang  

72

360

7,200 

1375358-1

5-1375358-1

110Connect Office Box, 2-Port and 4-Port 

144

720

14,400

1375353-1

5-1375353-1

ORDERING INFORMATION

WIREMOLD is a trademark.

Part Number

Description

Label Size (W x H)

Labels per Sheet

Figure

5 Sheets

100 Sheets

Card Stock

1.98" x 0.373"

72

A

1375356-1

5-1375356-1

Self-adhesive Polyester

1.98" x 0.373"

72

A

1375357-1

5-1375357-1

Card Stock

1.88" x .600"

45

B

2111415-1

5-2111415-1

Self-adhesive Polyester

1.88" x .600"

45

B

2111416-1

5-2111416-1

Sc3_Copper_06_Accessories_v1.indd   105

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-106

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

Labels for Patch Panels

FEATURES

• 

All labels are designed to fit panels listed in referenced compatibility

• 

Labels are supplied on 8.5 x 11" sheets

• 

Card stock labels are perforated and compatible with inkjet and laser printers

• 

Self-adhesive polyester labels are pre-cut and compatible with laser printers

• 

Special 0.25" high label is provided for use when icons are also desired

• 

For use with:

110Connect Cat 6 patch panels and mini patch panels

110Connect Cat 5e patch panels and mini patch panels

110Connect Cat 5 patch panels and mini patch panels

SL series multimedia patch panels and mini patch panels

• 

48-port 1RU SL Cat5e and Cat6 patch panels

Description

Label Size (W x H)

Labels per Sheet

Labels per Package

Part Number

5 Sheets

100 Sheets

5 Sheets

100 Sheets

Card Stock

3.10" x 0.50"

36

180

3600

1375351-1

5-1375351-1

Self-adhesive Polyester

3.10" x 0.50"

36

180

3600

1375352-1

5-1375352-1

3.30" x 0.25"

72

360

7200

1375353-1

5-1375353-1

Card Stock

3.54" x .500"

36

180

3600

2111413-1

5-2111413-1

Self-adhesive Polyester

3.54" x .500"

36

180

3600

2111414-1

5-2111414-1

Self-adhesive Polyester

3.54" x .250"

72

360

7200

2111415-1

5-2111425-1

ORDERING INFORMATION

FEATURES

• 

Includes twenty-five sheets, four clear plastic label covers per sheet

• 

For use with Category 6, 5e, 5 and SL Series Multimedia Patch Panels

• 

Included with compatible patch panels

Label Covers for Patch Panels

Description

Part Number

Label Covers for Patch Panels

1116044-2

ORDERING INFORMATION

Sc3_Copper_06_Accessories_v1.indd   106

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-107

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

Labels for 110Connect XC Cross-Connect Wiring Blocks

FEATURES

• 

Labels are designed to fi t TE's AMP NETCONNECT 610XC and 110Connect XC 
Cross-connect systems and other similar products

• 

     Card stock labels: designed to fi t into standard clear designation strips, 
available in TIA/EIA-606-A compliant colors, perforated, and compatible with 
inkjet and laser printers

• 

     White self-adhesive polyester labels: designed for easy application to the front 
of the clear designation strips, pre-cut and compatible with laser printers

• 

     Labels are supplied on 8.5 x 11"sheets

Description

Label Size (W x H)

Labels per Sheet Color

90 Labels (5 Sheets) 1800 Labels (100 Sheets)

Card Stock

7.90" x 0.48"

18

White

1375354-1

5-1375354-1

Blue

1375354-2

5-1375354-2

Green

1375354-3

5-1375354-3

Self-adhesive Polyester

7.90" x 0.48"

18

White

1375355-1*

5-1375355-1*

*Note: Available in white only.

Clear Label holders are used with 110Connect XC cross-connect systems.

Description

Part Number

Clear Label 110Connect XC Wiring Blocks

558417-1

Clear Label Holder for 110Connect XC Wiring Blocks

ORDERING INFORMATION

ORDERING INFORMATION

Labels for Cable and Cable Assemblies

FEATURES

• 

    Labels are designed for use on cable and cable assemblies

• 

     Labels are pre-cut and compatible with laser printers

Description

Application

Label Size (W x H)

Labels per 
Sheet

Labels per Package

Part Number

5 Sheets

100 Sheets

5 Sheets

100 Sheets

Self-adhesive Polyester

4-Pair Cable

0.984" x 1.496"

48

240

4800

1479002-1

5-1479002-1

25-Pair Cable

0.984" x 2.480"

24

120

2400

1479003-1

5-1479003-1

ORDERING INFORMATION

Description

Label Size (W x H)

Labels per Sheet

Labels per Package

Part Number

5 Sheets

100 Sheets

5 Sheets

100 Sheets

Card Stock

3.10" x 0.50"

36

180

3600

1375351-1

5-1375351-1

Self-adhesive Polyester

3.10" x 0.50"

36

180

3600

1375352-1

5-1375352-1

3.30" x 0.25"

72

360

7200

1375353-1

5-1375353-1

Card Stock

3.54" x .500"

36

180

3600

2111413-1

5-2111413-1

Self-adhesive Polyester

3.54" x .500"

36

180

3600

2111414-1

5-2111414-1

Self-adhesive Polyester

3.54" x .250"

72

360

7200

2111415-1

5-2111425-1

Sc3_Copper_06_Accessories_v1.indd   107

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-108

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

Description

New Card FP 
2111415 

New Adhesive FP 
5111416

Card Stock 
1375356

Self-Adhesive 
1375357

Self-Adhesive 
1375358

Self-Adhesive 
1375353

Part Number

Labeled Faceplate Kit

X

X

2111008

X

X

2111009

X

X

2111010

X

X

2111011

X

X

2111012

X

X

2111013

X

X

2111014

X

X

2111015

Non-Labled Faceplate Kits

X

2111021

X

2111022

X

2111023

X

2111024

X

2111025

SL Series Faceplates

X

X

1339118

X

X

1479486

Angled Faceplates 

X

X

1375155

X

X

406185

Hideaway Outlet

X

503999

X

503997

X

503998

Hideaway Multimedia Outlet

X

X

1479815

X

X

1479946

Multimedia Security Outlet

1116535

Surface Mount Outlet

557366

12-Port Universal Office Box

X

X

1479358

Modular Jack Boxes

X

1116697

X

1116698

Wiremold Raceway Faceplates

X

X

1375050

X

X

1375049

SL Series Furniture Outlets

X

1375005

X

1375006

4-Pair cable assemblies available in all part numbers with self-adhesive 1479002
25-Pair cable assemblies available in all part numbers with self-adhesive 1479003

ORDERING INFORMATION

Faceplate/Outlet and Label Compatibility List

WIREMOLD is a trademark.

Sc3_Copper_06_Accessories_v1.indd   108

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-109

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

Description

Part Number

Patch Panel Assembly

Front Load Housing

New-Card PP 2111413
New-Adhesive PP 2111414

1933307

1933308

1933309

1933310

1933198

1933319

1933320

1933321

1933322

1933412

1933776

1933199

4-Pair cable assemblies available in all part numbers with self-adhesive 1479002
25-Pair cable assemblies available in all part numbers with self-adhesive 1479003

ORDERING INFORMATION

Faceplate/Outlet and Label Compatibility List

Description

Part Number

Patch Panel Assembly 

Rear Load Housing 
 

Card-Stock     FP  1375351
Self-Adhesive FP 1375352
Self-Adhesive FP 1375353

406390

406981

406330

406331

406332

1499604

1499605

1479206

1479208

1375013

1375014

1375015

1375016

1499600

1499601

1479153

1479154

1479155

1479156

1499602

1499603

Sc3_Copper_06_Accessories_v1.indd   109

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-110

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Description

Part Number

110xc Cross Connect   

Card-Stock 1375354
Self-Adhesive 1375355

558841

558842

558843

558839

558840

569432

569433

569434

569438

469439

569440

569444

569445

569446

569853

569854

569855

569856

569857

569858

558635

558637

558639

4-Pair cable assemblies available in all part numbers with self-adhesive 1479002
25-Pair cable assemblies available in all part numbers with self-adhesive 1479003

ORDERING INFORMATION

Faceplate/Outlet and Label Compatibility List

Sc3_Copper_06_Accessories_v1.indd   110

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-111

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

*Note: Replace XX with: 

01 = 1' 

07 = 7'

 

 

 

04 = 4' 

10 = 10'

HighBand 

to Series 2 adapter

HighBand 

dummy plug

HighBand 

marking cap

HighBand 

bridging test cord

HighBand 

“look-both-ways” 

test cord

HighBand  

winged test adapter

HighBand  

disconnect plug

Copper Connectivity Solutions – Accessories and Labels

Description

Quantity

Part Number

HighBand 10 to Series 2 adapter

   1-pair adapter accepts any single pair Series 2 test cord for HighBand 10 testing

1

6451 2 178-04

Red dummy plug

    Plastic plug inserts into test/patch port of Ultim8 or HighBand 10 blocks for quick identification of special 

circuits. Flat surface can be written on or accepts a small adhesive sticker. Plugs block access to the pair and 
prevent accidental removal of jumper wires

100

6451 5 035-00

Red marking cap

    Plastic cap snaps over an Ultim8 or HighBand 10 block pair for quick identification of special circuits. Caps block 

access to prevent accidental removal of jumper wires, but do not interfere with patching

20

6462 2 101-01

Disconnect plug

    Plastic plugs insert into the patch/test port of Ultim8 or HighBand 10 blocks to open (disconnect) a circuit

20

      White

6462 2 097-00

      Green

6462 2 097-20

Bridging test cord

   1-pair connector to two banana plugs (connect to test equipment); used to test parallel to the circuit

6648 2 900-XX*

“Look-both-ways” test cord

   1-pair connector to four banana plugs; provides ability to isolate cable side from jumper side

1

6648 2 901-XX*

Winged test adapter

   Provides ability to monitor a circuit without disruption

1

6646 3 001-01

Ultim8/Highband 10 1-pair site mounted test cord

    Monitor or “look-both-ways” test circuit with flip of a switch. Mounts on 1 position of back mount frame or 

directly on a wall. Includes RJ11 jack to quickly isolate feeder or distribution network problems

1

6645 2 127-XX*

ORDERING INFORMATION

Sc3_Copper_06_Accessories_v1.indd   111

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-112

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Type 105 Label Holder

Type 105 label holder

The label holder mounts on a universal mounting system mounting 
bracket in the Type 105 position, a Type 105 mounting bracket or a 
Type 105 rod mount bracket to provide extensive labeling. Jumper 
rings on both sides provide additional wire management. Each label 
holder requires one block position. A paper label and plastic cover 
are included. Accepts label part number: 6631 3 106-XX.

Type 105 Label Strip

Type 105 label strip 

shown on HighBand 10 block

Recommended for patched environments, this transparent label 
strip snaps onto the face of an Ultim8 or HighBand 10 block. The 
label strip covers only the top row of the block and is fully visible 
with patch cords in place. Includes slide-in paper labels  
(Part number: 6631 3 102-XX) or can be written on directly.

Description

Dimensions (HxWxD)

Part Number

Type 105 label strip  Quantity per Pack: 10

0.81" x 4.25" x 0.88" 
(20.6 mm x 107.9 mm x 22.2 mm)

6462 2 096-00

ORDERING INFORMATION

Description

Dimensions (HxWxD)

Part Number

Type 105 label holder  Quantity: 1

0.81" x 5.63" x 1.31" 
(20.57 mm x 143 mm x 33.27 mm)

6630 2 004-05

ORDERING INFORMATION

Type 105 Hinged Label Holder

Recommended for jumpered environments, the holder snaps onto a block face 
to provide a hinged cover over the block termination contacts and patch/test 
ports. A clear plastic protective cover and a paper label (Catalog Number: 6631 
3 100-03) are included for each side of the hinged cover. The hinged label holder 
extends 0.38 inches (9.5 mm) from the face of the block.

Description

Dimensions (HxWxD)

Part Number

Type 105 hinged label holder  Quantity: 1

0.63" x 4.31" x 0.63" 
(16 mm x 109.5 mm x 16 mm)

6089 2 015-01

ORDERING INFORMATION

Hinged label holder

open

Hinged label holder  

closed

Sc3_Copper_06_Accessories_v1.indd   112

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-113

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Paper Labels

Label Sheet for Type 105 

Hinged

Label Sheet for Type 105 

Label Holder

Label Sheet for Type 105 

Label Strip

Based on ANSI/TIA/EIA-606-A, May 1, 2002

Tech Tip 

– Use of the TIA/EIA-606 color standards greatly increases identification of network 

system components. TE strongly recommends following standards whenever possible.

Color

Identifies

Orange

Demarcation point (e.g., central office terminations)

Green

Network connections (e.g., network and auxiliary equipment)

Purple

Common equipment, PBX, LANs, multiplexers (e.g., switching and data equipment)

White

First level backbone (e.g., main cross-connect [MC (campus distributer [CD])] to a horizontal cross-connect 
[HC (floor distributer [FD])] or to an intermediate cross-connect [IC (building distributer [BD])])

Gray

Second level backbone (e.g., IC [BD] to a HC [FD])

Blue

Horizontal cable (e.g., horizontal connections to telecommunications outlets; formerly referred to as 
“station cable”)

Brown

Interbuilding backbone (campus cable terminations)
NOTE: Brown takes precedence over white or gray for interbuilding runs

Yellow

Miscellaneous (e.g., auxiliary, alarms, security)

Red

Reserved for future use (also, key telephone systems)

EXAMPLES OF TIA/EIA-606 COLOR CODING

Side-Mount Label Holder

Side-mount label holder

The holder mounts onto the side of any Ultim8 or HighBand 10 block. 
Two side-mount label holders attach to each block, one on each side. 
A small rectangular paper label is included with each holder.

Description

Dimensions (HxWxD)

Part Number

Side-mount label holder  Quantity: 1

0.63" x 1" x 0.31" (16 mm x 25.4 mm x 7.87 mm)

6462 2 016-00

ORDERING INFORMATION

Sc3_Copper_06_Accessories_v1.indd   113

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

Copper

Copper Accessories

3-114

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Paper Labels

*Replace XX with: 

00 = orange 

05 = brown

 

01 = green 

06 = yellow

 

02 = purple 

07 = red

 

03 = gray 

08 = white

 

04 = blue

Description

Part Number

Paper label sheet for Type 105 hinged label holder   

Quantity: 1 sheet per package 

Labels come pre-cut on a white, 8.5" x 11" sheet, with 50 labels per sheet; accommodate hand or laser printing

6631 3 100-03

Paper label sheets in TIA/EIA-606 colors for Type 105 hinged label holder   

Quantity: 1 sheet per package  

Labels come pre-cut on an 8.5" x 11" sheet with 50 labels per sheet; accommodate hand or laser printing

6631 3 105-XX*
Not available in 
-05 (brown), 
-06 (yellow), 
-07 (red) or 
-08 (white)

Paper label sheet for Type 105 label holder   

Quantity: 1 sheet per package

Labels come pre-cut on an 8.5" x 11" sheet, with 26 labels per sheet

6631 3 106-XX*

Paper label sheet for Type 105 label strip   

Quantity: 1 sheet per package

Labels come perforated on an 8.5" x 11" sheet, 20 labels per sheet; accommodate hand or laser printing.  
Available in all TIA/EIA-606 specified colors, two colors per sheet (one color on each side)

   Orange, red

6631 3 102-01/09

   

Green, purple

6631 3 102-02/03

   

White, blue

6631 3 102-04/06

   

Gray, brown

6631 3 102-05/07

   

Yellow, white

6631 3 102-08

ORDERING INFORMATION

Sc3_Copper_06_Accessories_v1.indd   114

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-115

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Tooling

Description

Part Number

SL Series Modular Jack Termination Tool

With Lacing Fixture

1725150-1

Without Lacing Fixture

1725150-3

Replacement Lacing Fixture

1673956-1

Step 4

Step 5

Step 6

Step 1

Step 3

Step 2

SL Series Modular Jack Termination 

Tool UTP Termination Method

SL Series Modular Jack Termination Tool and Accessories

FEATURES

• 

Termination tool for SL series jacks

• 

Simplifi es the termination 

• 

More consistent terminations

• 

Terminates and cuts all 8 conductors at once

• 

Simplifi es lacing process and speeds up terminations

• 

Tool without lacing fi xture is for use with SL series AMP-TWIST 6A 
modular jacks

• 

Termination video can be viewed at www.te.com/EnterpriseNetworks

ORDERING INFORMATION

Sc3_Copper_06_Accessories_v1.indd   115

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-116

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Tooling

110 Punch Down Tools with Blades

FEATURES

• 

The industry standard termination tool for all 110Connect terminations

• 

Each tool comes with a blade

• 

For use with 110Connect and SL series modular jacks and other 110-style terminations

Description

Figure

Part Number

Pro Impact Tool with Extended-Life Blade

A

1375308-1

Standard Impact Tool with Standard Blade

B

1583608-1

Non-Impact Tool with Standard Blade

C

1583236-1

Figure A

Figure B

Figure C

ORDERING INFORMATION

Extended-life blades have a lifetime three times longer than standard blades.

110 Punch Down Tool Replacement Blades

Description

Figure

Part Number

Extended-Life 110 Blade

A

1375309-1

Extended-Life 66/110 Blade

B

1375310-1

Figure A

Figure B

ORDERING INFORMATION

Pro-Installer Twisted Pair Tool Kit

For use with 110Connect and SL Series modular jacks and other 110-style terminations

FEATURES

• 

Installer’s knife

• 

Pro impact tool with extended-life blade

• 

Shears

• 

TE's AMP NETCONNECT tool pouch

Description

Part Number

Pro-Installer Twisted Pair Tool Kit

1375307-1

ORDERING INFORMATION

Sc3_Copper_06_Accessories_v1.indd   116

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-117

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Tooling

Palm Grip Tool
 

FEATURES

• 

Fits comfortably into one hand

• 

Holds one 110Connect jack, one SL Series 110Connect jack, or ACO 110 card edge 
connector for termination

Description

Part Number

Palm Grip Tool 

569949-1 

ORDERING INFORMATION

KRONE Insertion Tool

Hook

Used to grab and remove 

wires for changes

Inhibitor Lock 

Prevents the automatic trimming of 

excess wire to enable daisy-chaining

FEATURES

• 

Insertion sensor ensures the conductor is fully inserted into the 
block contacts before allowing any excess wire to be cut off

• 

An inhibitor lock prevents the scissors from operating—particularly useful in 
applications in which conductors are daisy-chained through several contacts

• 

Universal scissors cut a variety of cable types, including 20 AWG through 26 
AWG and Type 1 foam-insulated conductors

• 

Specially designed wire hook removes terminated conductors

• 

Blade helps to remove blocks easily from back mount frames

ORDERING INFORMATION

Description

Part Number

Insertion tool  Quantity: 1

6417 2 055-01

Disposable tool  Quantity: 1

Terminates wire into contact, will not cut excess 
wire; snips required to cut off excess wire

6417 3 006-01

Blade 

Used to remove termination 

blocks from back mount frames

Sc3_Copper_06_Accessories_v1.indd   117

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-118

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Tooling

Figure A

Figure B

Cable Strippers and Cutters
 

FEATURES

• 

Cyclops stripper suitable for use with UTP Cable

• 

Coaxial stripper can be adjusted for use with RG-6, RG-58 and RG-59 cable

Description

Figure

Part Number

Cyclops Cable Stripper

A

1375317-1

Coaxial Cable Stripper

B

1490490-1

Diagonal Cutters

C

1116571-1

Figure C

PRO-CRIMPER III Hand Tool and Die Sets for Twisted Pair Applications
 

FEATURES

• 

Ratchet control provides complete termination cycle 

• 

Interchangeable die sets accommodate all plug sizes

• 

Sold with or without die.  Dies can be purchased separately

Description

Part Number

PRO-CRIMPER III Hand Tool

354940-1

Tooling for External 8 Position  
Category 3, 5 and 5e Modular Plugs

Hand Tool and Die Set

224928-1

Die Set Only

224928-2

ORDERING INFORMATION

ORDERING INFORMATION

Sc3_Copper_06_Accessories_v1.indd   118

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-119

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Tooling

Tooling Category 6 Modular Plugs 
 

FEATURES

• 

Used with Category 6 modular plugs

• 

Ratchet control provides complete termination cycle

• 

Die set and tool crimps both the strain relief and the modular contacts at the same time

• 

Interchangeable die sets accommodate all plug sizes

• 

Sold with or without die. Dies can be purchased separately

ORDERING INFORMATION

Description

Part Number

Hand Tool Only

354940-1

Die Set Only

1-790163-0

790163-6

790163-2

Tool with Die

790163-9

790163-5

790163-1

Cable OD

6–7 mm

5–6 mm

Plug Style

Full Body

Short

Long

1479682

x

1479683

x

1479185

x

1479184

x

1375202

x

1357204

x

2111283

x

2111434

x

1499598

x

1933433

x

Sc3_Copper_06_Accessories_v1.indd   119

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-120

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

Copper

Copper Tooling

Pro-Installer’s Modular Plug Hand Tool 
 

FEATURES

• 

Ratchet control provides complete termination cycle

• 

Sold with and without die sets

• 

Interchangeable die sets accommodate all plug sizes

• 

Die set to modular plug cross-reference shown 

ORDERING INFORMATION

Hand Tool without Die: 2-231652-0

DOT COLOR

Gray

White

Blue

Violet

Black

Die Only P/N

1-853400-4

1-853400-0

853400-8

853400-7

853400-1

Hand Tool with Die

3-231652-6

3-231652-0

2-231652-8

2-231652-7

2-231652-1

Cat 3 and Cat 5

1479583

x

1479584

x

1479585

x

1479586

x

554169

x

554170

x

554710

x

554720

x

554739

x

555042

x

555174

x

555175

x

555177

x

555426

x

557315

x

558530

x

569278

x

569550

x

569552

x

569530

x

569532

x

569542

x

641337

x

641335

x

Cat 6

1933373

x

1933374

x

2111262

x

Sc3_Copper_06_Accessories_v1.indd   120

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-121

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Tooling

Description

Included Components

Part Number

Hand Tool

High Performance, 

8-Position Die Set

8-Position 

Line Die Set

6-Position,Long 

Body Die Set

4- & 6-Position 

Line Die Set

4-Position 

Handset Die Set

2-231652-0

1-853400-0

853400-1

853400-7

853400-8

853400-3

Pro-Installer’s Mod 
Plug Hand Tool Kits

X

X

X

X

X

1-231666-4

X

X

X

X

X

1-231666-3

X

X

X

X

1-231666-2

X

X

X

X

1-231666-1

X

X

X

1-231666-0

Carrying Case, Blade Replacement Kit and Screw Driver ONLY

231666-9

Replacement Blade Kit (5 Cutters and 5 sets of Strip Blades)

231662-5

Cutter Blade

856727-1

Pro-Installer’s Modular Plug Hand Tool Kits and Accessories  
 

FEATURES

• 

Each kit contains carrying case, blade replacement kit, screw driver, and  
items as listed

• 

Modular plug to die set cross reference listed as shown

ORDERING INFORMATION

Sc3_Copper_06_Accessories_v1.indd   121

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-122

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Tooling

Pistol Grip Tool for AMP-BARREL Edge Connectors

FEATURES

• 

The pistol grip tool terminates AMP-BARREL edge connectors one pair at a time

• 

Shortens assembly time by trimming conductors to the proper length and helps 
maintain proper pair twist for high performance cables

• 

This tool requires the installation kit to be fitted with a special edge connector, 
part number 406351-1

Description

Part Number

Pistol Grip Tool with Head

58568-1

Head only

122533-1

AMP-BARREL Wire Insertion Tools

• 

Used to insert and terminate wires into the special edge connector for use with 
the pistol grip tool

• 

Wire insertion tools for undercarpet transition blocks may be used to insert 
and terminate wires into AMP-BARREL connectors used in undercarpet cabling 
system transition blocks

• 

Wire insertion tools for undercarpet transition blocks cuts off conductor when it 
is inserted

For Use With:

Figure

Part Number

ACO Edge Connectors

A

556706-1

Wire Insertion Tool for UC Transition Blocks

B

231890-1

Figure B

Figure A

ORDERING INFORMATION

ORDERING INFORMATION

Sc3_Copper_06_Accessories_v1.indd   122

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-123

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

C

OPPER

 

Copper

Copper Tooling

Portable “Butterfly” Hand Tool (MI-1) for CHAMP 25-Pair Connectors
 

FEATURES

• 

Mass terminates and shears all wires in a single operation

• 

Wires can be laced in tool or in separate lacing fixture

• 

Base plate can be bench-mounted

Description

Part Number

Standard 14-50 Positions, 90° Wire Dress

229378-1

Optional Lacing Fixture

230328-3

  

Palm Grip Hand Tool Kits 
 

FEATURES

• 

14 to 64-position kit includes wire inserter, all 5 sizes of index slides, cable 
clamp, insertion/extraction tool (230238-1), and carrying case

• 

50-position kit includes wire inserter, 50-position index slide and cable clamp

Description

Part Number

14 to 64-Position

229764-2

50-Position only

229451-2

ORDERING INFORMATION

ORDERING INFORMATION

Description

Figure

Part Number

Contact Insertion/Extraction Tool

A

230238-1

T-Handle Wire Insertion Tool

B

229384-1

Insertion/Extraction Tools 
 

FEATURES

• 

Used with CHAMP Connectors

• 

Wire insertion tool is used to insert individual wires when making repairs

• 

Contact insertion/extraction tool is used to replace damaged contacts

Figure A

Figure B

ORDERING INFORMATION

Sc3_Copper_06_Accessories_v1.indd   123

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-124

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

Copper

Copper Tooling

Twisted Pair Testing Tools  
 

FEATURES

• 

4-Pair UTP Tester:

 

 Tests for opens, shorts and wire map (mis-wires, reversals, and split pairs)

 

Auto-on/off feature 

 

 Battery low indicator

• 

Butt Set:

 

LCD display shows: on-hook voltage, number dialed, off-hook current, caller ID, 
stored numbers, etc.

 

 Tone and pulse dialing

 

 6-Position modular cord set attachment included

 

Auto-off feature

• 

Tone Generator:

 

Three built-in tones

 

 Auto-off feature

 

Separate talk battery for increased voltage and power for test sets

 

 6-Position modular jack allows multiple cord/test lead sets to be used for 
different applications

 

Comes with test lead set

• 

Tone Tracer:

 

Permits wire and cable identification without direct metallic contact

 

Ergonomic design

 

Can be used with any tone generator

 

Quick change tips available

Description

Figure

Part Number

4-Pair UTP Tester

A

1490530-1

Butt Set

B

1490532-1

Tone Generator

C

1490531-1

Tone Tracer

D

1490533-1

Figure A

Figure C

Figure B

Figure D

ORDERING INFORMATION

Sc3_Copper_06_Accessories_v1.indd   124

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-125

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

Copper

Copper Solution Guide

19-Inch Rack

2 post, 3" deep

1933559-1

4 post adjustable

1933570-1

Cable Management

Horizontal 2RU panel

Single sided

1933532-1

Double sided

1933533-1

Double-sided 
vertical manager

6"

1933534-1

6" Combination

1933540-1

Cat 5e UTP Cable - 520 series

Plenum

TE520P-XXYY**

Riser

TE520R-XXYY**

*x denotes color: white, blue

Cat 5e UTP Patch Panel

Straight SL

24 port

1479154-2

Straight SL

48 port

1479155-2

Angled SL

24 port

1499602-2

Angled SL

48 port

1499603-2

Dynamic

24 port

PP24AC5ET

Dynamic

48 port

PP48AC5ET

Cat 5e UTP Cable Assemblies

White

TCPC-5ERUVB-WTxx*

Blue

TCPC-5ERUVB-BLxx*

*denotes length

Cat 5e UTP Termination Blocks

110Connect XC

100-pair kit 

569439-1

300-pair kit 

569445-1

Cable trough 

with legs

569389-1

Cat 5e UTP Outlet

Faceplate single gang 
w/ label and icons

1 port

2111008-x*

2 port

2111009-x*

4 port

2111011-x*

Surface Mount Module

2 port

1933668-x*

4 port

1933671-x*

RJ45 without dust cover

1375191-x

RJ45 with dust cover

1375190-x

*denotes color, **denotes  color(XX) and packaging (YY)

Category 5e UTP Solution

1

2

3

5

6

7

8

1

2

3

5

6

7

8

1

Sc3_Copper_06_Accessories_v1.indd   125

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-126

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

Copper

Copper Solution Guide

19-Inch Rack

2 post, 3" deep

1933559-1

4 post adjustable

1933570-1

Cable Management

Horizontal 2RU panel

Single –sided

1933532-1

Double -sided

1933533-1

Double-sided 
vertical manager

6"

1933534-1

6" Combination

1933540-1

Cat 6 UTP Cable - 620 series

Plenum

TE620P-XXYY**

Riser

TE620R-XXYY**

*x denotes color: white, blue

Cat 6 UTP Patch Panel

Straight

24 port

1375014-2

Straight

48 port

1375015-2

Angled

24 port

1499600-2

Angled

48 port

1499601-2

Dynamic Angled

24 port

PP24AC6T

Dynamic Angled

48 port

PP48AC6T

Cat 6 UTP Cable Assemblies

White

TCPC-6RUVB-WTxx*

Blue

TCPV-6RUVB-BLxx*

*denotes length

Cat 6 UTP Termination Blocks

HighBand

300-pair kit - 

12-way kit

6450 1 101-10

HighBand 25 

cable trough

6450 2 157-00

Vertical Management 

Rings

6450 2 156-20

Vertical Management 

Cover

6450 2 158-20

Cat 6 UTP Outlet

Faceplate single gang 
w/label and icons

1 port

2111008-x*

2 port

2111009-x*

4 port

2111011-x*

Surface Mount Module

2 port

1933668-x*

4 port

1933671-x*

RJ45 without dust cover

1375055-x

RJ45 with dust cover

1375187-x

*denotes color, **denotes  color(XX) and packaging (YY)

Category 6 UTP Solution

1

2

3

5

6

7

8

1

2

3

5

6

7

8

1

Sc3_Copper_06_Accessories_v1.indd   126

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-127

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

Copper

Copper Solution Guide

19-Inch Rack

2 post, 3" deep

1933559-1

4 post adjustable

1933570-1

Cable Management

Horizontal 2RU panel

Single -sided

1933532-1

Double -sided

1933533-1

Double-sided 
vertical manager

6"

1933534-1

6" Combination

1933540-1

Cat 6A UTP Cable 

Plenum

TE640P-XXYY**

Riser

TE640R-XXYY**

Cat 6A UTP Patch Panel

Dynamic

24 port

PP24AC6AT

48 port

PP48AC6AT

Cat 6A U/UTP Cable Assemblies

568B

White

6645-2-805-YY*

Blue

6645-2-825-YY*

*YY denotes length

Cat 6A UTP Termination Blocks

HighBand

144-pair kit - 

12-way kit

6450 1 107-01

HighBand 25 

cable trough

6450 2 157-00

Vertical Management 

Rings

6450 2 156-20

Vertical Management 

Cover

6450 2 158-20

Cat 6A UTP Outlet

Faceplate single gang 
w/ label and icons

1 port

2111036-x*

2 port

2111037-x*

4 port

2111039-x*

Surface Mount Module

2 port

1933668-x*

4 port

1933671-x*

RJ45 without dust cover

6830 1 835-x

*x denotes color, **denotes  color (XX) and packaging (YY)

Category 6A UTP Solution

1

2

3

5

6

7

8

1

2

3

5

6

7

8

1

Sc3_Copper_06_Accessories_v1.indd   127

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

3-128

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

C

OPPER

 

Copper

Copper Solution Guide

19-Inch Rack

2 post, 3" deep

1933559-1

4 post adjustable

1933570-1

Cable Management

Horizontal 2RU panel

Single-sided

1933532-1

Double-sided

1933533-1

Double-sided 
vertical manager

6"

1933534-1

6" Combination

1933540-1

Cat 6A F/UTP Cable 

Plenum

TE640PF-XXYY**

Riser

TE640RF-XXYY**

*denotes color: white, blue

Cat 6A Shielded Patch Panel

Straight

24 port

1933319-2

Straight

48 port

1933320-2

Angled

24 port

1933321-2

Angled

48 port

1933322-2

Cat 6A F/UTP Cable Assemblies

White

x-1933885-x*

Blue

x-1933882-x*

*denotes length

Cat 6A Shielded Outlet

Faceplate single gang 
w/ label and icons

1 port

2111008-x*

2 port

2111009-x*

4 port

2111011-x*

Surface Mount Module

2 port

1933668-x*

4 port

1933671-x*

RJ45 without dust cover

1711342-2

RJ45 with dust cover

1711160-2

*denotes color, **denotes color (XX) and packaging (YY)

Category 6A Shielded Solution

1

2

3

5

6

7

8

1

2

3

6

7

8

1

Sc3_Copper_06_Accessories_v1.indd   128

12/7/12   3:09 PM

Tyco-catalog-AMP-2013-html.html
background image

4-1

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Work Area Outlets

Faceplates and Outlets ................................................................................

4-3

Inserts ....................................................................................................................

4-21

For a finished look, TE offers a variety of work area outlet 
products to enhance accessibility and improve aesthetics. From 
faceplates and mounting straps, to desktop monuments and 
surface boxes, TE has a wide selection of outlet options for both 
business and residential applications. Available in a choice of 
colors and styles, our work area outlet products are installed in 
thousands of buildings and homes worldwide. From education 
institutions and hospitals, to retailers and large, hi-rise apartments 
and condominiums, TE’s work area outlet solutions are offered in 
a variety of modern styles and designs. 

Sc4_WorkAreaOutlets_v1.indd   1

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-3

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

Faceplates and Outlets

TE Connectivity's new modern design improve the appearance of outlet areas that 
house data, telephony and A/V connectors in everything from classrooms and 
hospitals to offices and homes. Our new faceplates offer molded icon slots and 
convex labels for maximum visibility in low density areas. Engineered for residential 
and commercial applications offer a wide range of port configurations, including 
single gang in 1-, 2-, 3-, 4- and 6-port configurations and double gang in 6-, 8- and 
12-port configurations. They accommodate unshielded and shielded AMP-TWIST 
and SL series jacks along with a variety of SL series multimedia inserts and SL 
series fiber inserts (MT-RJ, LC). 

Faceplates and Accessories
 

FEATURES

• 

Accepts all AMP-TWIST jacks, SL series jacks, 110Connect jacks, 
MT-RJ outlet jacks and SL series inserts

Single gang dimensions:
– 2.75" (69.85 mm) x
– 4.5" (114.30 mm) x
– 0.22" (5.59 mm)

• 

Models available with and without labeling options

• 

Label areas with integrated, hinged covers

• 

Mold-over icon and leveling (for icons see copper 
accessories section)

• 

Improved label viewing area is larger with integrated, convex 
label covers that flip down and snap in place

• 

Larger radius on the faceplate edge and the convex shape of the 
label covers allow labels to be more easily viewed from above 
when faceplates are behind furniture

• 

Extender kits are used to add 0.5" (12.7 mm) of space between 
the mounting surface and the faceplate

Extender kit dimensions:
– 5.21" (132.33 mm) x
– 2.89" (73.50 mm) x
– 0.50" (12.70 mm)

• 

Oversize adapter plate will accept any style single or double 
gang faceplate. Dimensions:  
5.75" (46.05 mm) x 6.00" (152.4mm) x .15" (3.81 mm)

• 

Drywall faceplate adapter used for adding outlet to wall with 
no backbox; compatible with all TE single gang faceplates; 
adjustable to fit 0.25" thick to 1" thick wallboard, paneling or 
drywall. Can be mounted horizontally or vertically and can be 
used as template for cutout hole; thin front lip design allows 
adapter to seat better on drywall

Figure A

Figure D

Figure G

Figure N

Figure B

Figure E

Figure L

Figure H

Figure J

Figure K

Figure C

Figure F

Figure M

Figure I

Figure O

Double gang dimensions:
– 4.56" (115.82 mm) x
– 4.5" (114.30 mm) x
– 0.22" (5.59 mm)

Figure Q

Figure P

Sc4_WorkAreaOutlets_v1.indd   3

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-4

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

Port 
Count

Footprint

Integrated 

Labeling Options

Orientation Figure

Part Number

Almond

Black

Gray

Electrical 
Ivory

Alpine 
White

1

Single Gang

Label covers and icons

Vertical

A

2111008-1

2111008-2

2111008-4

1-2111008-1

1-2111008-3

None

Vertical

B

2111021-1

2111021-2

2111021-4

1-2111021-1

1-2111021-3

2

Single Gang

Label covers and icons

Vertical

C

2111009-1

2111009-2

2111009-4

1-2111009-1

1-2111009-3

None

Vertical

D

2111022-1

2111022-2

2111022-4

1-2111022-1

1-2111022-3

3

Single Gang

Label covers and icons

Vertical

E

2111010-1

2111010-2

2111010-4

1-2111010-1

1-2111010-3

None

Vertical

F

2111023-1

2111023-2

2111023-4

1-2111023-1

1-2111023-3

4

Single Gang

Label covers and icons

Vertical

G

2111011-1

2111011-2

2111011-4

1 2111011-1

1 2111011-3

Horizontal

H

2111203-1

2111203-2

2111203-4

1-2111203-1

1-2111203-3

None

Vertical

I

2111024-1

2111024-2

2111024-4

1-2111024-1

1-2111024-3

6

Single Gang

Label covers and icons

Vertical

J

2111012-1

2111012-2

2111012-4

1-2111012-1

1-2111012-3

None

Vertical

K

2111025-1

2111025-2

2111025-4

1-2111025-1

1-2111025-3

Double Gang

Label covers and icons

Vertical

L

2111013-1

2111013-2

2111013-4

1-2111013-1

1-2111013-3

8

Double Gang

Label covers and icons

Vertical

M

2111014-1

2111014-2

2111014-4

1-2111014-1

1-2111014-3

12

Double Gang

Label covers and icons

Vertical

N

2111015-1

2111015-2

2111015-4

1-2111015-1

1-2111015-3

Extender Kit

O

2111201-1

2111201-2

2111201-4

1-2111201-1

1-2111201-3

Oversize Adapter Plate

P

2111332-1

1-2111332-3

Drywall Faceplate Adapter

Q

6644 2 019-00

ORDERING INFORMATION

Sc4_WorkAreaOutlets_v1.indd   4

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-5

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

SL Series Faceplates
 

FEATURES

• 

Single gang and double gang footprint

• 

Single gang faceplates accept three 1 unit or two 1.5 unit SL series modules

• 

Double gang, double-sided faceplates accept three 1 unit or two 1.5 unit
SL series modules on each side

• 

Front-loading modules eliminate need to remove faceplates from wall for
changes or repairs

• 

Double gang, double-sided SL series faceplates:

Dimensions: 0.675" D x 4.490" W x 4.540" H

For use with openings a minimum of 2.81" x 3.59" (not suitable for mud
rings/device covers)

Figure A

Figure B

Part Number

Description

Width

Figure Almond

Black

Gray

Electrical Ivory

Alpine White

SL Series 
Faceplates

Single Gang

Single-sided

A

1339118-1

1339118-2

1339118-4

1-1339118-1

1-1339118-3

Double Gang

Double-sided

B

1479486-1

1479486-2

1479486-4

1-1479486-1

1-1479486-3

ORDERING INFORMATION

Figure A

Figure F

Figure M

Figure B

Figure H

Figure I

Figure J

Figure C

Part Number

Description

Units

Figure

Almond

Black

Gray

Electrical Ivory

Alpine White

Blank

1

A

1116410-1

1116410-2

1116410-4

1-1116410-1

1-1116410-3

1.5

B

1116407-1

1116407-2

1116407-4

1-1116407-1

1-1116407-3

SC Duplex

singlemode, Blue Coupler

1

C

1375306-1

1375306-2

1375306-4 1-1375306-1

1-1375306-3

SVGA

Unloaded

1

F

1479079-1

1479079-2

1479079-4 1-1479079-1

1-1479079-3

2-Port

Straight

1

H

1116409-1

1116409-2

1116409-4

1-1116409-1

1-1116409-3

Angled

1.5

I

1116406-1

1116406-2

1116406-4

1-1116406-1

1-1116406-3

3-Port

Angled

1.5

J

1116408-1

1116408-2

1116408-4

1-1116408-1

1-1116408-3

HDMI

Unloaded

1

M

1933686-1

1933686-2

1933686-4 1-1933686-1

1-1933686-3

ORDERING INFORMATION

SL Series Modules

FEATURES

• 

Modules fit SL series faceplates

• 

Front loading

• 

2-Port modules are suitable for use with all SL series jacks,
MT-RJ outlet jacks and SL series inserts

• 

3-Port module is suitable for use with unshielded SL Series
Jacks, MT-RJ outlet jacks and SL series multimedia inserts

• 

SVGA multimedia modules are unloaded for use with 15 position
subminiature D connectors (sold separately)

Sc4_WorkAreaOutlets_v1.indd   5

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-6

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

ORK AREA OUTLET

S

ORDERING INFORMATION

Angled Faceplates

FEATURES

• 

Accept all AMP-TWIST jacks, SL series jacks, MT-RJ outlet jacks and SL
series inserts

• 

Angled port allows connector to exit downward protecting connector and
allowing closer furniture placement

Part Number

Description

Port Count

Figure

Almond

Black

Gray

Electrical Ivory

Alpine White

Angled Faceplates

2

A

1375155-1

1375155-2

1375155-4

1-1375155-1

1-1375155-3

4

B

406185-1

406185-2

406185-4

1-406185-1

1-406185-3

Figure A

Figure B shown 

with jacks

Figure B

ORDERING INFORMATION

Wall Phone Faceplate

FEATURES

• 

For use with 110Connect or SL series modular jacks

• 

Features studs used to mount standard wall mount telephones

Part Number

Description

Almond

Electrical Ivory

Alpine White

Wall Phone Faceplate

1479152-1

1-1479152-1

1-1479152-3

Sc4_WorkAreaOutlets_v1.indd   6

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-7

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

Part Number

Description

Port Count

Figure

Almond

Black

Gray

Electrical Ivory

Alpine White

Angled Faceplates

2

A

1375155-1

1375155-2

1375155-4

1-1375155-1

1-1375155-3

4

B

406185-1

406185-2

406185-4

1-406185-1

1-406185-3

ORDERING INFORMATION

Description

Port Count

Foot Print

Duplex Power

Labeling

Figure

Semtron Part Number

SEMTRON Stainless Steel 
Wall Phone Faceplate

1

Single Gang

A

1FM-ØE-AMP-PHONE

SEMTRON Stainless Steel 
Faceplates

1

Single Gang

B

1FM-ØE-AMP-LAB

2

Single Gang

1FM-ØØE-AMP

with Labels and 

Label Covers

C

1FM-ØØE-AMP-LAB

Double 

Gang

with Duplex 

Opening

2FM-DØØE-AMP

3

Single Gang

with Labels and 

Label Covers

1FM-(3)ØE-AMP-LAB

4

Single Gang

1FM-(4)ØE-AMP

with Labels and 

Label Covers

D

1FM-(4)ØE-AMP-LAB

Double 

Gang

with Duplex 

Opening

2FM-D(4)ØE-AMP

6

Single Gang

1FM-(6)ØE-AMP

with Labels and 

Label Covers

1FM-(6)ØE-AMP-LAB

Double 

Gang

with Duplex 

Opening

E

2FM-D(6)ØE-AMP

with Labels and 

Label Covers

F

2FM-(6)ØE-AMP-LAB

12

Double 

Gang

with Labels and 

Label Covers

2FM-(12)ØE-AMP-LAB

Stainless Steel Faceplates from Semtron
 

FEATURES

• 

Faceplates with labels have slotted mounting holes that allow for
faceplate alignment at installation

• 

Flush mount installation

• 

1FM-ØE-AMP-PHONE is for use with 110Connect or SL series
modular jacks and features studs used to mount standard wall
mount telephones

• 

2-, 4- and 6-Port Faceplates accept SL series jacks, AMP-TWIST
jacks, MT-RJ outlet jacks, and SL series inserts

• 

Double gang stainless steel faceplates with power additionally
accept one duplex power receptacle (sold separately)

• 

These faceplates are available directly from:

Semtron, Inc.

6465 Corunna Rd.
Flint, MI 48532
Phone: 1-800-732-9080
Fax: 810-732-9665
Email: semtron@semtron.com
Web: www.semtron.com

Figure B

Figure E

Figure C

Figure F

Figure A

Figure D

Sc4_WorkAreaOutlets_v1.indd   7

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-8

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

Part Number

Description

Port Count

Figure

Almond

Black

White

Gray

Electrical Ivory

106 Duplex Mounting Strap

2

A

1116618-1

1116618-2

1116618-3

1116618-4

1-1116618-1

4

B

1339120-1

1339120-2

1339120-3

1339120-4

1-1339120-1

Decorator Mounting Strap

2

C

1479784-1

1479784-2

1479784-3

1479784-4

1-1479784-1

3

D

1116616-1

1116616-2

1116616-3

1116616-4

1-1116616-1

4

E

1479504-1

1479504-2

1479504-3

1479504-4

1-1479504-1

Mounting Straps  
 

FEATURES

• 

Accept SL series jacks, MT-RJ outlet jacks,  
and SL Series inserts

• 

Duplex mounting straps fit standard  
duplex faceplates

• 

Decorator mounting straps fit standard  
decorator faceplates

• 

Allow easy mounting of communications outlets in 
power poles and floor pedestals

• 

Accommodates icons for port identification

Faceplates for Mounting Straps
 

FEATURES

• 

Duplex faceplates accept 2- and 4-port duplex
mounting straps

• 

Decorator faceplates accept 2-, 3- and 4-port decorator
mounting straps

ORDERING INFORMATION

ORDERING INFORMATION

Figure A

Figure A

Figure C

Figure C

Figure B

Figure B

Figure D

Figure E

Part Number

Description

Footprint

Figure Almond

Black

White

Gray

Electrical Ivory

Decorator Faceplate

Single Gang

A

1479159-1

1479159-2

1479159-3

1479159-4

1-1479159-1

Double Gang

B

1479625-1

1479625-2

1479625-3

1479625-4

1-1479625-1

Duplex Faceplate

Single Gang

C

1479160-1

1479160-2

1479160-3

1479160-4

1-1479160-1

Sc4_WorkAreaOutlets_v1.indd   8

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-9

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

ORK AREA OUTLET

S

Part Number

Description

Port Count

Figure

Almond

Black

White

Gray

Electrical Ivory

106 Duplex Mounting Strap

2

A

1116618-1

1116618-2

1116618-3

1116618-4

1-1116618-1

4

B

1339120-1

1339120-2

1339120-3

1339120-4

1-1339120-1

Decorator Mounting Strap

2

C

1479784-1

1479784-2

1479784-3

1479784-4

1-1479784-1

3

D

1116616-1

1116616-2

1116616-3

1116616-4

1-1116616-1

4

E

1479504-1

1479504-2

1479504-3

1479504-4

1-1479504-1

Part Number

Description

Footprint

Figure Almond

Black

White

Gray

Electrical Ivory

Decorator Faceplate

Single Gang

A

1479159-1

1479159-2

1479159-3

1479159-4

1-1479159-1

Double Gang

B

1479625-1

1479625-2

1479625-3

1479625-4

1-1479625-1

Duplex Faceplate

Single Gang

C

1479160-1

1479160-2

1479160-3

1479160-4

1-1479160-1

ORDERING INFORMATION

Description

Included Faceplate

Part Number

Almond

White

Stainless Steel

HIDEOUT Outlet Kit

Screw-on

503997-1

503997-3

503998-1

Snap-on

503999-1

503999-3

HIDEOUT Outlets

FEATURES

• 

Double gang box with single gang cover recommended

• 

May not fi t all single gang boxes

• 

Hides and protects cable connections

• 

Feeds from bottom to allow fl ush furniture placement

• 

Fits standard electrical boxes

• 

Icons in copper accessories section

• 

Each kit includes sub-plate, faceplate, adhesive labels, cable ties, and
mounting screws. Media modules and icons must be ordered separately

• 

Accepts the following (see table for detailed load information):

Shielded or unshielded SL Series jacks

Unshielded 110Connect jacks

MT-RJ outlet jacks

Duplex fi ber optic adapters

MT-RJ parallel dress clips

SL series inserts

• 

Shielded SL series jacks work in bottom row of faceplate only

Screw-on Cover

Snap-on Cover

Accepted Connectivity

Maximum Load Capacity

Option 1

Option 2

Option 3

Option 4

Unshielded SL Series, 110Connect Jacks, 
MT-RJ Outlet Jacks, or SL Series Inserts

4

2

0

0

Shielded SL Series Jacks

0

2

2

0

Duplex Fiber Optic Adapters, or MT-RJ Parallel Dress Clips

1

1

1

2

SPECIFICATIONS

Sc4_WorkAreaOutlets_v1.indd   9

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-10

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

Part Number

Port Count

Figure

Almond

Black

White

Gray

Electrical Ivory

4

A

1479946-1

1479946-2

1479946-3

1479946-4

1-1479946-1

6

B

1479815-1

1479815-2

1479815-3

1479815-4

1-1479815-1

HIDEAWAY Multimedia Outlets
 

FEATURES

• 

Accepts the following (see table for detailed load information):

Shielded and unshielded SL series jacks

AMP-TWIST jacks

MT-RJ outlet jacks

Duplex couplers

MT-RJ parallel dress clips

SL Series inserts

• 

Fit single and double gang electrical J-boxes

• 

Feature “invisible” icon holes which remain hidden until used

• 

Feature integral tabs for easy fiber loop management

• 

Breakaway tabs in duplex fiber coupler cut outs allow HIDEAWAY outlets to accept
“flangless” SECURE LC duplex, standard LC duplex, or hybrid LC duplex couplers
with retention clips (break out the tabs when using standard duplex couplers)

Accepted Connectivity

Maximum Load Capacity

4-Port

6-Port

Unshielded SL Series, MT-RJ Outlet Jacks, or SL Series Inserts

4

6

Shielded SL Series Jacks, AMP-TWIST Jacks

4

4

Duplex Fiber Optic Adapters, or MT-RJ Parallel Dress Clips

2

2

ORDERING INFORMATION

Figure A

Figure B

SPECIFICATIONS

Sc4_WorkAreaOutlets_v1.indd   10

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-11

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

ORDERING INFORMATION

Description

Part Number

Surface Mount Outlet Assembly - Top, bottom, label, cover, hardware, 8 blank inserts

557366-1

Blank Insert

557361-1

Surface Raceway Adapter

557685-1

Duplex ST or Duplex SC Insert (Fiber receptacles not included)

1116111-1

Dual ST Bulkhead Adapter Insert (Receptacle included)

557350-1

Single 110Connect Jack, SL Series or MT-RJ Insert  (Jack not included)

1116098-1

Dual 110Connect Jack, SL Series or MT-RJ Insert (Jacks not included)

557775-1

Surface Mount Outlet and Accessories
 

FEATURES

• 

Provides a convenient and aesthetically pleasing workstation outlet for virtually
all network needs

• 

Capability to install mixed media: coax, fiber and twisted pair

• 

Simply select the adapter kits for the media being used and install them in the
surface mount outlet

• 

The kit is shipped with matching icons

• 

Surface mount outlet is available in almond only

The application chart is a suggested loading pattern
for the surface mount outlet. The surface mount
outlet inserts can be configured according to
network requirements. The size of the connectors,
however, limits some applications. In particular, the
corner slots present some loading problems when
using larger connectors. Therefore, this application
chart was developed to assist in adjacent corner
connector configuration. The “X” denotes the
suggested loading patterns for the corner slots of
the surface mount outlet.

Dual

 ST

 or

 S

C

110C

onnect,

  SL

 S

eries, 

or

 MT

-R

Jacks

Dual 

110C

onnect,

 SL

 S

eries, 

or

 MT

-R

Jacks

Dual ST or SC

X

110Connect, SL Series, or MT-RJ Jacks

X

X

X

Dual 110Connect, SL Series, or MT-RJ Jacks

X

SUGGESTED LOADING PATTERN FOR THE SURFACE MOUNT OUTLET

Sc4_WorkAreaOutlets_v1.indd   11

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-12

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

Surface Mount Modules
 

FEATURES

• 

Provide flexible surface mounting of 2-, 4- or 6-ports

• 

Accept AMP-TWIST, SL series jacks, MT-RJ outlet jacks, and SL series inserts

• 

Compatible with most surface raceway systems and modular furniture raceways

• 

Modules include label, clear label cover, double-sided foam tape, self-tapping
screws, and cable ties

• 

Modules can be mounted with magnets (purchased separately)

• 

Dimensions:

2-port: 1.5" H x 3.0" W x 4.0" D

4-port: 1.5" H x 5.6" W x 4.6" D

6-port: 1.5" H x 5.6" W x 4.6" D

Figure A

Figure B

Figure C

Figure D

Part Number

Description 

Port Count

Figure

Almond

Black

Gray

Electrical Ivory

Alpine White

Surface Mount Modules

2

A

1933668-1

1933668-2

1933668-4

1-1933668-1

1-1933668-3

4

B

1933671-1

1933671-2

1933671-4

1-1933671-1

1-1933671-3

6

C

1933674-1

1933674-2

1933674-4

1-1933674-1

1-1933674-3

Surface Mount Module Magnets  

Pack of 4

D

1933677-1

ORDERING INFORMATION

Sc4_WorkAreaOutlets_v1.indd   12

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-13

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

Part Number

Description 

Port Count

Figure

Almond

Black

Gray

Electrical Ivory

Alpine White

Surface Mount Modules

2

A

1933668-1

1933668-2

1933668-4

1-1933668-1

1-1933668-3

4

B

1933671-1

1933671-2

1933671-4

1-1933671-1

1-1933671-3

6

C

1933674-1

1933674-2

1933674-4

1-1933674-1

1-1933674-3

Surface Mount Module Magnets  

Pack of 4

D

1933677-1

12-Port Universal Surface Mount Outlet
 

FEATURES

• 

Accepts all SL series jacks, 110Connect jacks, MT-RJ outlet jacks, and SL series inserts

• 

Molded numbering for each port

• 

Low profile design

• 

Features fiber loop storage

• 

Compatible with most surface raceways

• 

Mounts to standard NEMA single and double gang surface boxes

• 

Integrated modular jack holder for terminations

• 

“Invisible” icon holes stay hidden until used

• 

Accommodates up to twelve 4-pair cables

Part Number

Description

Almond

Black

White

Gray

Electrical Ivory

Alpine White

12-Port Universal Surface Mount Outlet

1479358-1

1479358-2

1479358-3

1479358-4

1-1479358-1

1-1479358-3

Surface Mount Module Magnets, Pack of 4

1479398-1

ORDERING INFORMATION

ORDERING INFORMATION

Figure A

Figure B

Part Number

Footprint

Figure

Almond

Black

White

Gray

Electrical Ivory

Alpine White

Single Gang

A

558251-1

558251-2

558251-3

558251-4

1-558251-1

1-558251-3

Double Gang

B

569499-1

569499-2

569499-3

569499-4

1-569499-1

1-569499-3

Surface Boxes
 

FEATURES

• 

One-piece construction simplifies installation

• 

Single gang surface box is 1

3/4

" deep

• 

Double gang surface box is 2" deep

Sc4_WorkAreaOutlets_v1.indd   13

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-14

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

ORDERING INFORMATION

Part Number

Description

Port Count

Figure

Almond

Gray

Faceplates for WIREMOLD Raceways

3

A

1375050-1

1375050-4

4

B

1375049-1

1375049-4

Faceplates for WIREMOLD Raceways
 

FEATURES

• 

Designed to be identical to Wiremold 5507 series
faceplates and will mount in 4049, 5400, and
5500 series device plates and brackets

• 

Accept all SL series jacks and multimedia inserts

• 

“Invisible” icon holes remain hidden when not used

Figure A

Figure B

ORDERING INFORMATION

Figure A

Figure B

Modular Jack Boxes 
 

FEATURES

• 

      Accepts unshielded SL series jacks, 
110Connect jacks and MT-RJ outlet jacks

• 

      “Invisible” icon holes remain hidden when not used

Part Number

Description

Port Count

Figure

Almond

Black

White

Gray

Electrical Ivory

Modular Jack Boxes

1-Port

A

1116697-1

1116697-2

1116697-3

1116697-4

1-1116697-1

2-Port

B

1116698-1

1116698-2

1116698-3

1116698-4

1-1116698-1

Blank Insert for Modular Jack Boxes

1933172-1

1933172-2

1933172-3

1933172-4

1-1933172-1

NOTE: Modular jack boxes do not accept Multimedia inserts. Blank Insert only works with these boxes.

WIREMOLD is a trademark.

Sc4_WorkAreaOutlets_v1.indd   14

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-15

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

Part Number

Description

Port Count

Figure

Almond

Gray

Faceplates for WIREMOLD Raceways

3

A

1375050-1

1375050-4

4

B

1375049-1

1375049-4

Part Number

Description

Port Count

Figure

Almond

Black

White

Gray

Electrical Ivory

Modular Jack Boxes

1-Port

A

1116697-1

1116697-2

1116697-3

1116697-4

1-1116697-1

2-Port

B

1116698-1

1116698-2

1116698-3

1116698-4

1-1116698-1

Blank Insert for Modular Jack Boxes

1933172-1

1933172-2

1933172-3

1933172-4

1-1933172-1

NOTE: Modular jack boxes do not accept Multimedia inserts. Blank Insert only works with these boxes.

Description

Color

Part Number

Wiremold 2A, 2-Port Inserts

Ivory

CM2-U2AMP

White

CM2-U2AMP-WH

Black

CM2-U2AMP-BK

Gray - Steel Raceway

CM2-U2AMP-G

Light Gray - Aluminum Raceway

CM2-U2AMP-GY

WIREMOLD 2A Inserts
 

FEATURES

• 

Allows the use of SL series jacks and inserts in Wiremold raceways, poke-thru
service fittings, and power poles

• 

Accepts up to two SL series jacks or inserts

• 

Installation and configuration ease

• 

Modules feature a front load snap-in design for ease of installation and
allowing outlet configuration changes to be made quickly

• 

To order contact:
The Wiremold Company
60 Woodlawn Street
West Hartford, CT 06110
1-800-621-0049
Fax: 860-232-2062
Web: www.wiremold.com

ORDERING INFORMATION

WIREMOLD is a trademark.

Sc4_WorkAreaOutlets_v1.indd   15

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-16

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

Figure A

Figure B

ORDERING INFORMATION

Description 

Color

Figure

Part Number

Power Monument, 15 Amp

Black

A

556222-3

Voice/Data Monument Empty Housing (requires FLEX-MODE Faceplate)

Black

B

1116360-3

Desktop Monuments
 

FEATURES

• 

Power monuments:

Provide access to duplex power outlet at the desktop

Eliminates the need to feed power cables behind or through desks

Supplied with an 8' (2.4 m), 3-prong power cord for connection to existing
electrical outlets

• 

Voice/Data monuments:

Accepts standard FLEX-MODE faceplates

Horizontal cabling can be connected directly to SL Series Modular Jacks
(recommended for category 5e applications)

• 

Attach to any desktop from 0.90" - 1.78" (22.9 mm - 45.2 mm)

• 

No special tools required to attach, simply place the monument onto the
edge of the desktop and tighten the integrated thumb screw

• 

UL listed and CSA certified

Sc4_WorkAreaOutlets_v1.indd   16

12/7/12   3:16 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-17

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

Standard FLEX-MODE Modular Furniture Faceplate Kits
 

FEATURES

• 

FLEX-MODE faceplates:

Accept all SL Series jacks, MT-RJ outlet jacks or SL Series inserts

Compatible with Telecommunications furniture outlet openings as
specified in ANSI/TIA-569-B standard

• 

110Connect 4-port modules:

Printed circuit board assemblies include 4 jacks

Ideal for thin panels

Panel Knockout

Dimensions

2.66” - 2.75”

1.34” - 1.40”

.045” - .080” thick

Part Number

Description

Port Count

Wiring

Figure

Almond

Black

Gray

Blank Plate

A

558471-2

558471-1

558471-4

FLEX-MODE Flush Faceplate

2

B

558106-2

558106-1

558106-4

3

C

558107-2

558107-1

558107-4

Category 5e, 110 Connect 4-Port Module

4

T568A/T568B

D

1116580-2

1116580-1

1116580-4

SL Series

4

E

1933134-2

1933134-1

1933134-4

ORDERING INFORMATION

Figure A

Figure C

Figure E

Figure B

Figure D

Sc4_WorkAreaOutlets_v1.indd   17

12/7/12   3:17 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-18

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

ORDERING INFORMATION

Figure A

Figure B

SL Series Furniture Outlets
 

FEATURES

• 

Accept up to 4 unshielded SL series jacks, MT-RJ outlet jacks and
SL series multimedia inserts

• 

Two bases adapt to a wide range of hole sizes

• 

Tabs on base fold over and crimp to furniture raceway cover

• 

“Invisible” icon holes stay hidden until used

Small Furniture Hole 

Size Range

1.375” - 
1.405”

2.656” - 2.750”

.045” - .080” thick

.045” - .080” thick

Large Furniture Hole 

Size Range

2.750” - 3.000”

1.750” -

1.900”

Part Number

Description

Figure

Almond

Black

White

Gray

SL Series Furniture Outlet

Small opening

A

1375005-1

1375005-2

1375005-3

1375005-4

Large opening

B

1375006-1

1375006-2

1375006-3

1375006-4

Sc4_WorkAreaOutlets_v1.indd   18

12/7/12   3:17 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-19

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

ORDERING INFORMATION

Figure A

Figure C

Figure B

Part Number

Description

Port Count

Figure

Almond

Black

Gray

Faceplate for Herman Miller Furniture

Flush

4

A

558357-2

558357-1

558357-4

Standard

2

B

569127-2

569127-1

569127-4

4

C

558191-2

558191-1

558191-4

Panel Knockout

Dimensions

2.92” - 3.03”

1.80” - 1.92”

.045” - .080” thick

Faceplates for Herman Miller Furniture 
 

FEATURES

 

• 

Flush faceplates:

 

Accepts unshielded 110Connect jacks, all SL series jacks 
and MT-RJ outlet jacks 

 

Jacks fit flush with front of faceplate

 

No backup plate required

• 

Standard faceplates:

 

Accepts unshielded 110Connect jacks, all SL series 
jacks, MT-RJ outlet jacks, and 110Connect and SL series 
Multimedia Inserts

 

May require backup plates depending on furniture style

Panel Knockout

Dimensions

2.85” - 2.95”

1.80” - 1.85”

Herman - Miller

.045” - .080” thick

Panel Knockout

Dimensions

2.85” - 2.95”

1.80” - 1.85”

Herman - Miller

.045” - .080” thick

Herman Miller is a trademark.

Sc4_WorkAreaOutlets_v1.indd   19

12/7/12   3:17 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Faceplates and Outlets

4-20

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

ORDERING INFORMATION

Figure A

Figure B

Part Number

Description

Figure

Almond

Black

Gray

STANDARD

Extender

A

1933468-2

1933468-1

1933468-4

Herman Miller

Extender

A

558488-2

558488-1

558488-4

Adapter

B

558493-2

558493-1

558493-4

KNOLL  

Prior to 1992

Extender

A

558489-2*

558489-1*

558489-4*

Adapter

B

558492-2*

558492-1*

558492-4*

* Note: Used to adapt standard FLEX-MODE Electrical faceplates to Knoll furniture manufactured prior to 1992.

Extenders and Adapters for Furniture Faceplates
 

FEATURES

• 

Extenders:

Use when depth of furniture panel is limited

Reduces panel opening to accept standard
FLEX-MODE faceplates

Raise outlet face approximately

3

/

4

"

above surface of raceway

• 

Adapters are used to adapt standard FLEX-MODE Faceplates
to other hole sizes

Herman Miller 

and *Knoll 

Panel Knockout

Dimensions

2.85” - 2.95”

1.80” - 1.85”

Herman - Miller

.045” - .080” thick
*Knoll: .045” thick

Standard

Panel Knockout

Dimensions

2.66” - 2.75”

1.34” - 1.40”

.045” - .080” thick

FLEX-MODE Modular Furniture Faceplate Accessories

Description

For use with

Figure

Part Number

Backup Plate

Herman Miller Action Office 2 and Ethospace Furniture (1991 or later)

A

608440-1

Accessory Clip

Herman Miller Furniture (before 1991)

B

608441-1

FigureA

Figure B

ORDERING INFORMATION

Herman Miller, Action Office and 
Ethospace are a trademarks.

Sc4_WorkAreaOutlets_v1.indd   20

12/7/12   3:17 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Inserts

4-21

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

FLEX-MODE Modular Furniture Faceplate Accessories

Description

For use with

Figure

Part Number

Backup Plate

Herman Miller Action Office 2 and Ethospace Furniture (1991 or later)

A

608440-1

Accessory Clip

Herman Miller Furniture (before 1991)

B

608441-1

Work Area Outlets

Inserts

SL Series Multimedia Inserts

TE Connectivity's AMP NETCONNECT SL series Inserts offer flexibility and 
density at the work area outlet. The Inserts are available in a variety of copper, 
fiber and A/V inserts to meet most multimedia applications. SL series Inserts 
can be installed in any AMP NETCONNECT faceplate or outlet designed to the 
SL series jack footprint.  

FEATURES

• 

May be used in straight or angled faceplates, SL series faceplate 
modules, surface mount modules, mounting straps and SL series 
patch panels

• 

Inserts easily snap into place

• 

RCA 110 termination multimedia jack:

Use where distances are less than 130'

For audio and video signals

Uses one pair of twisted-pair cable

White, red or yellow dielectrics to match home theater equipment

Not recommended for component DVD connections

• 

S-Video 110 termination multimedia jack:

Use where distances are less than 130'

For S-Video Y/C (luminance/chrominance black 
and white/color) signals

Uses two pairs of a standard twisted-pair cable

• 

Front Load SVGA

Suitable for standard keystone wall plates

Accepts wire gauge sizes from 20 to 28

Supports cable types

5 conductor mini-coax

4 pair performance cable

Figure D

Figure H

Figure J

Figure N

Figure A

Figure E

Figure K

Figure O

Figure C

Figure G

Figure I

Figure M

Figure Q

Figure B

Figure F

Figure L

Figure P

Figure R

Sc4_WorkAreaOutlets_v1.indd   21

12/7/12   3:17 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Inserts

4-22

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

Work Area Outlets

Inserts

Part Number

Insert Type

Figure Almond

Black

White

Gray

Electrical Ivory

Alpine White

3.5 mm Stereo, 
Mini-Headphone

Screw Terminal

A

1933582-1

1-1933582-3

Blank

B

1116412-1

1116412-2

1116412-3

1116412-4

1-1116412-1

1-1116412-3

BNC Coupler

C

2111615-1

2111615-2

1-2111615-3

F-Connector 
Coupler

2 GHz

D

1499855-1

1499855-2

1499855-3

1499855-4

1-1499855-1

1-1499855-3

RCA to 
110 Punch Down

Red Dielectric

E

1479230-1

1-1479230-3

White Dielectric

1479231-1

1-1479231-3

Yellow Dielectric

1479232-1

1-1479232-3

RCA Coupler

Red Dielectric

F

1375361-1

1-1375361-3

White Dielectric

G

1375362-1

1-1375362-3

Yellow Dielectric

1375363-1

1-1375363-3

Green Dielectric

1933192-1

1-1933192-3

Blue Dielectric

1933193-1

1-1933193-3

Orange Dielectric

1933194-1

1-1933194-3

RCA to F-Connector

H

1933096-1

1-1933096-3

ST Coupler

Multimode

I

1339123-1

1339123-2

1-1339123-3

Singlemode

I

1479181-1

1479181-2

1-1479181-3

Speaker Post

Black Stripe

J

1479190-1

1-1479190-3

Red Stripe

K

1479191-1

1-1479191-3

SC Simplex Coupler

Singlemode/Multimode

L

1499836-1

1499836-2

1499836-3

1499836-4

1-1499836-1

1-1499836-3

S-Video

M

1375149-2

USB  A to A Coupler

N

1933659-1

1933659-2

1-1933659-3

USB  B to A Coupler

O

1933661-1

1-1933661-3

HDMI Coupler

P

2111500-2

Front Load SVGA

Q

1-2111550-3

LC Duplex Coupler

Beige, OM1  

(62.5 

µ

m) Multimode

1-1933286-2

Black, OM2  

(50 

µ

m) Multimode

1-1933286-1

Aqua, OM3 and OM4  

(XG 50 

µ

m) Multimode

1933286-6

Green, Singlemode APC

1933286-3

Blue, Singlemode

R

1933286-4

Note: APC (Angle Polish Connector) couplers are for use with angle polished connectors.

ORDERING INFORMATION

Sc4_WorkAreaOutlets_v1.indd   22

12/7/12   3:17 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Inserts

4-23

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

O

RK ARE

A

 OUTLET

S

Part Number

Insert Type

Figure Almond

Black

White

Gray

Electrical Ivory

Alpine White

3.5 mm Stereo, 
Mini-Headphone

Screw Terminal

A

1933582-1

1-1933582-3

Blank

B

1116412-1

1116412-2

1116412-3

1116412-4

1-1116412-1

1-1116412-3

BNC Coupler

C

2111615-1

2111615-2

1-2111615-3

F-Connector 
Coupler

2 GHz

D

1499855-1

1499855-2

1499855-3

1499855-4

1-1499855-1

1-1499855-3

RCA to 
110 Punch Down

Red Dielectric

E

1479230-1

1-1479230-3

White Dielectric

1479231-1

1-1479231-3

Yellow Dielectric

1479232-1

1-1479232-3

RCA Coupler

Red Dielectric

F

1375361-1

1-1375361-3

White Dielectric

G

1375362-1

1-1375362-3

Yellow Dielectric

1375363-1

1-1375363-3

Green Dielectric

1933192-1

1-1933192-3

Blue Dielectric

1933193-1

1-1933193-3

Orange Dielectric

1933194-1

1-1933194-3

RCA to F-Connector

H

1933096-1

1-1933096-3

ST Coupler

Multimode

I

1339123-1

1339123-2

1-1339123-3

Singlemode

I

1479181-1

1479181-2

1-1479181-3

Speaker Post

Black Stripe

J

1479190-1

1-1479190-3

Red Stripe

K

1479191-1

1-1479191-3

SC Simplex Coupler

Singlemode/Multimode

L

1499836-1

1499836-2

1499836-3

1499836-4

1-1499836-1

1-1499836-3

S-Video

M

1375149-2

USB  A to A Coupler

N

1933659-1

1933659-2

1-1933659-3

USB  B to A Coupler

O

1933661-1

1-1933661-3

HDMI Coupler

P

2111500-2

Front Load SVGA

Q

1-2111550-3

LC Duplex Coupler

Beige, OM1  

(62.5 

µ

m) Multimode

1-1933286-2

Black, OM2  

(50 

µ

m) Multimode

1-1933286-1

Aqua, OM3 and OM4  

(XG 50 

µ

m) Multimode

1933286-6

Green, Singlemode APC

1933286-3

Blue, Singlemode

R

1933286-4

Note: APC (Angle Polish Connector) couplers are for use with angle polished connectors.

ORDERING INFORMATION

MT-RJ, LC Adapters and SL

FEATURES

• 

Easily snap into place

• 

MT-RJ SL series housing accepts one MT-RJ jack sold separately

• 

LC adapters and SL series housings are purchased separately to mix and match
custom color port identification

Description

Figure

Color

Part Number

MT-RJ SL Series Housing

A

Almond

1374416-1

Black

1374416-2

White

1374416-3

Gray

1374416-4

Orange

1374416-5

Blue

1374416-6

Red

1374416-7

Yellow

1374416-8

Green

1374416-9

Violet

1-1374416-0

Electrical Ivory

1-1374416-1

Rose

2-1374416-3

Aqua

2-1374416-4

Brown

2-1374416-5

Slate

2-1374416-6

SL Series LC Housing

B

Light Almond

2111408-1

Black

2111408-2

Orange

2111408-5

Blue

2111408-6

Red

2111408-7

Yellow

2111408-8

Green

2111408-9

Beige

1-2111408-2

Alpine White

1-2111408-3

Aqua

2-2111408-4

Duplex LC Adapter

C

Blue

2111407-2

Green

2111407-5

Beige

2111407-6

Black

2111407-7

Aqua

2111407-8

Figure A

Figure B

Figure C

Sc4_WorkAreaOutlets_v1.indd   23

12/7/12   3:17 PM

Tyco-catalog-AMP-2013-html.html
background image

Work Area Outlets

Inserts

4-24

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

W

ORK AREA OUTLET

S

Multimedia Modules for Work Area Outlets

FEATURES

• 

SVGA 110 termination modules:

Supported resolutions:
–VGA (640 x 480)
–SVGA (800 x 600)
–XGA (1024 x 760)

Features 110-Style termination for easy installation

Is suitable for use with standard Category 5e or 6
UTP or F/UTP (recommended) cables

Can be used where distances between monitor and computer do not exceed:
–20' with Cat 5e or 6 UTP cable
–35' with Cat 5e or 6 FTP cable

Utilizing drain wire for 9th conductor is recommended for use with FTP cables

Dimensions: 1.180" D x 1.480" W x 0.875" H

Stuff er caps and hex head stand-off screws included

Fits SVGA blank SL series module, P/N: 1479079

• 

SVGA screw terminal termination module:

Works with VGA and SVGA signals

Allows fi eld termination of SVGA cable

For distances of up to 150' at a resolution of 800 x 600 using standard 5
conductor 26 AWG coaxial video cable

Fits SVGA blank SL series module, P/N:1479079

• 

SVGA - Screw terminal

Allows fi eld termination of SVGA cable

For distances up to 150'

Supported Resolutions: 800 x 600

Recommended for use with 5 conductor, 26 AWG stranded coaxial video cable

• 

HDMI modules fi t into HDMI blank SL series module, P/N: 1933686

Description

Figure

Part Number

HDMI Adapter Cable Assembly, Type A

B

1933636-2

SVGA Assembly, 110 Termination

C

1479287-2

SVGA Assembly, Screw Terminal Termination

D

1933424-2

ORDERING INFORMATION

Figure B

Figure D

Figure C

Sc4_WorkAreaOutlets_v1.indd   24

12/7/12   3:17 PM

Tyco-catalog-AMP-2013-html.html
background image

5-1

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Managed Connectivity

ICM .................................................................................................................. 5-3 

Quareo .......................................................................................................... 5-7

Businesses and organizations worldwide are more dependent on 
their physical layer than ever before. From computers, phones and 
wireless devices, to alarm systems, security cameras and video 
conferencing, today’s network physical layer touches virtually every 
device inside an organization. Security of the physical layer also has 
become a top concern among network and data center managers, 
especially in healthcare, financial and mission-critical organizations 
where data is required to be secure. 

TE's Managed Connectivity solution, with its Infrastructure 
Configuration Manager (ICM) software and Quareo Connection 
Point Identification hardware technology, delivers full knowledge 
and visibility of the physical layer. ICM can be seamlessly integrated 
into your existing network management software to give full control 
and visibility of the complete network helping to establish the 
highest security standards possible. These solutions enable higher 
network availability, while lowering network costs, by integrating 
full visibility of the physical layer into existing network management 
applications – all the way from the data center to the desktop. 
TE’s Managed Connectivity solutions are helping network and data 
center managers bridge the gap between network management 
and physical layer management, transforming the physical layer into 
a strategic asset and revolutionizing the way networks are managed 
and controlled. By providing a real-time comprehensive picture of 
every connection point in the physical layer, managed connectivity 
significantly improves productivity and efficiency of physical layer 
management and maintenance processes while reducing costly 
downtime and operating costs. 

For more information on TE's Managed Connectivity solution, visit 
www.knowyournetwork.com.

Sc5_ManagedConnect_01_ICM_v1.indd   1

12/7/12   3:38 PM

Tyco-catalog-AMP-2013-html.html
background image

Managed Connectivity

Infrastructure Configuration Manager (ICM)

5-3

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

MANA

GED C

ONNE

C

TIVITY

Infrastructure Configuration Manager (ICM) is a software application specifically designed for customers 
of TE’s managed connectivity solutions. ICM powers TE’s advanced Quareo connection point identification 
technology, providing customers with a single platform for both solutions.

ICM creates an automated, accurate, real-time physical layer management system that is designed to 
explore, discover and map all the connections of the network, allowing data center and network managers 
to simplify the process of all moves, adds and changes, improve security and reduce operating expense.

TE’s managed connectivity solutions, enabled by ICM, help customers eliminate time-consuming manual 
work order processes, easily identify and locate specific ports, auto-discover IP assets, and trace data center 
circuits from the switch through the cross-connect to the server. The systems also help maximize network 
investment by identifying under-utilized assets and improving security through real-time monitoring and 
programmable alerts.

FEATURES 

When used with Quareo, ICM allows immediate response to changes in connectivity and automatically 
records the connections of the physical layer cabling system and its devices with accurate 
documentation. Other advantages of deploying ICM include:

• 

Accountability of assets by location and date

• 

Availability of assets and utilization is improved

• 

Reduced operational costs

• 

Best practice and regulatory requirements are more easily attained

• 

Network problems are more easily diagnosed and corrected

• 

Security is greatly enhanced

• 

Remote visibility of the physical layer

Sc5_ManagedConnect_01_ICM_v1.indd   3

12/7/12   3:38 PM

Tyco-catalog-AMP-2013-html.html
background image

5-4

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

MANA

GED C

ONNECTIVITY

Managed Connectivity

Infrastructure Configuration Manager (ICM)

Graphical 
User 
Interface

INFRASTRUCTURE CONFIGURATION MANAGER

P H Y S I C A L   L AY E R

Layer 2 

Devices

Quareo

CPID

Technology

D

A

T

A

B

A

S

E

LAYER 2 DISCOVERY AGENT                       QUAREO AGENT

Third Party 

Applications

API

DCIM

NMS

Facility Apps



The advanced system architecture allows full 
customization of the graphical user interface. Multiple 
users and multiple screens can be supported enhancing 
the usefulness of the system. Diff erent color schemes 
are available that can be applied on a per user basis 
enhancing the user interface experience.

The graphical user interface supports multiple screens 
that visualize the network physical infrastructure in a 
detail not previously available. User access and profi les 
can be secured and controlled to a granular level based 
on responsibilities, roles and use cases.

The network infrastructure can be viewed in a classical 
tree hierarchy with branches nested below. Additionally, 
multiple drawings of a building can be added to the 
database and these can be allocated to diff erent parts 
of the building, fl oor or room that is documented. These drawings can have network 
assets 'placed' and these assets remain dynamic within the drawing, allowing for 
information to be coordinated and viewed with a single click.

The network rack, cabinet or closet can be documented and visualized in full detail 
that shows the front and rear of any installed assets. Patch cables and their planned 
routing can be viewed including estimated minimum lengths.

Circuit traces can be viewed showing every element of the circuit path from switch 
port to end device and all intermediate steps.

Sc5_ManagedConnect_01_ICM_v1.indd   4

12/7/12   3:38 PM

Tyco-catalog-AMP-2013-html.html
background image

Managed Connectivity

Infrastructure Configuration Manager (ICM)

5-5

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

MANA

GED C

ONNE

C

TIVITY

OTHER KEY FEATURES INCLUDE:

• 

Automatic discovery: Switches and 
end devices can be discovered and 
placed in the DB

• 

Multiple reports: Powerful report tool 
with support for BIRT reporting

• 

Accurate and simple search: Full 
contextual search with filtering by 
class available

• 

User/Role configuration: Flexible 
user configuration supports LDAP 
and local passwords

• 

Work Order system: Flexible work 
order system for full work flow 
management

• 

API and SDK: Ease of integration 
with third-party software

• 

Fully compatible with Quareo AIM 
systems

Asset details are recorded and displayed in multiple screens and views. These 
details combine discovered and manually provided information. Asset utilization 
can be continually monitored with charts/meters providing instantaneous and 
real time updates at a glance. All documented information can be searched in 
real time and items immediately displayed.

With a fully documented network, reports can be used to provide active 
and passive utilization, availability and asset details. ICM contains numerous 
reports but also provides flexibility for users to write and tailor reports to suit 
organizational and compliance needs.

ICM boasts over 30 different views or ‘frames’ of information, many of them 
graphical in nature, which can be used individually for specific details, or in 
combination to perform common tasks or determine more complex findings.

With pre-defined screen layouts of typically required frames of information, the 
ICM software is organized into seven common tasks:

Custom views and combinations of various frames can be established and 
saved for specific tasks or processes that require unique determinations or 
information. Basic views that are most commonly used as building blocks to 
make basic determinations and support common tasks are:

Equipment View:

Accurate real time view of equipment in closet or rack

Asset Tree:

View of all network assets showing parents 

and children

Asset Details:

View specific network components with details from 

location to utilization

Circuit Traces:

View end-to-end circuits with all connection points

Plan View:

Floor plan can be added with interactive ‘links’ to 

assets and locations

Event View:

Real-time view of all events and status with filters

Alarms:

Configurable alarms with status, persistence and 

acknowledgement capabilities

• 

System status

• 

Network explorer

• 

Work orders 

• 

Alarms

• 

User administration 

• 

Reports

• 

System configuration

Sc5_ManagedConnect_01_ICM_v1.indd   5

12/7/12   3:38 PM

Tyco-catalog-AMP-2013-html.html
background image

Managed Connectivity

Infrastructure Configuration Manager (ICM)

5-6

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

MANA

GED C

ONNE

C

TIVITY

MINIMUM SERVER HARDWARE REQUIREMENTS

• Processor:

 Dual core 2 GHz or higher (x64) processor required

• Memory:

 8 GB

• Available Disk Space:

 20 GB

• Network connection:

 1 GB Network card

SERVER OPERATING SYSTEM REQUIREMENTS:

• Microsoft® Windows Server® 2008 R2 (64-bit)
• Red Hat® Enterprise Linux® 5.4 and above (64-bit)

DATABASE REQUIREMENTS

As part of the installation process, the following database platform will be

installed on your server:

• PostgreSQL 9.1
• Apache™ Tomcat™ web server

OTHER REQUIREMENTS

• Java Runtime Engine 1.6 or higher 

(can be installed as part of ICM installation)

• Adobe Flash Player 11.1.102.62 or higher

 (client desktop only)

• Administrator log in privileges on the server for installation 

SUPPORTED WEB BROWSERS

• IE 8 or higher
• Firefox 10.0.2 or higher

(Although ICM may work in other browsers, they have not been tested, and are not supported at this time)

Microsoft Windows Server, Red Hat Enterprise Linux, Apache Tomcat, Adobe, and Firefox are trademarks.

ORDERING INFORMATION

Description

Part Number

ICM Software 

is available either bundled with specific  

AIM hardware/ analyzers or stand-alone in the following  
license-blocks by managed monitored port counts

480 Port License

5-1899725-2

2400 Port License

5-1899725-3

4800 Port License

5-1899725-4

9600 Port License

5-1899725-5

24,000 Port License

5-1899725-6

48,000 Port License

5-1899725-7

96,000 Port License

5-1899725-8

ICM API/SDK

5-1899725-9

Description

Access

Help - Desk Support

Part Number

Annual Maintenance  
The ICM 

Maintenance SLA covers 
updates and help-desk 
support on an annual 
basis based on port 
thresholds as shown in 
the table below. Technical 
Assistance Center (TAC) 
access includes patches 
and bug fixes as well as 
minor and major releases.

480 Ports

One Year TAC

M - F 8:00 am to 5:00 pm CST/CDT

6-1899725-0

Three Year TAC

6-1899725-2

2400 Ports

One Year TAC

6-1899725-4

Three Year TAC

6-1899725-6

4800 Ports

One Year TAC

6-1899725-8

Three Year TAC

7-1899725-0

9600 Ports

One Year TAC

7-1899725-2

Three Year TAC

7-1899725-4

24000 Ports

One Year TAC

7-1899725-6

Three Year TAC

7-1899725-8

48000 Ports

One Year TAC

8-1899725-0

Three Year TAC

8-1899725-2

96000 Ports

One Year TAC

8-1899725-4

Three Year TAC

8-1899725-6

Sc5_ManagedConnect_01_ICM_v1.indd   6

12/7/12   3:38 PM

Tyco-catalog-AMP-2013-html.html
background image

5-7

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

MANA

GED C

ONNECTIVITY

Managed Connectivity

Quareo

FEATURES

•  Support IEEE 802.3ae and IEEE 802.3ba

•  Exceed ANSI/TIA-568-C.3 and ISO 11801 Edition 2 cabling system requirements 

•  OM3/OM4 and OS1

•  19-Inch rack mountable

•  Available in 2, 4, and 8 slot chassis

•  48 Fiber (24 Duplex LC) LC-to-LC or LC to MPO blade

•  192 Fiber (16 MPO Ports) MPO-to-MPO blade

ORDERING INFORMATION

Product Description

Part Number

1RU Network Chassis, Accommodates 2 each Q3 or Q4 series blades

QCH-1RU

2RU Network Chassis, Accommodates 4 each Q3 or Q4 series blades

QCH-2RU

4RU Network Chassis, Accommodates 8 each Q3 or Q4 series blades

QCH-4RU

Q4000 Series

Quareo Series Network Chassis

Q4000 Series Network Chassis featuring Quareo Technology allows network 

personnel to view, manage and audit the physical layer. This means, for the first time, 

the physical layer is now subject to the same compliance policy as higher layers of 

the network. With 70% of network outages attributed to errors made in the physical 

layer, TE introduces a new category of products. Simply put, Quareo enables 

Managed Connectivity using connection point identification (CPID) technology.

Product Description

Part Number

QDR-1RU:

 Quareo 1RU Front Door Kit

QDR-1RU

QDR-2RU:

 Quareo 2RU Front Door Kit

QDR-2RU

QDR-4RU:

 Quareo 4RU Front Door Kit

QDR-4RU

Product Description

Part Number

QBCB-HR:

 Front Blank Cover (used to cover 

up unpopulated chassis positions)

QBCB-HR

ORDERING INFORMATION

Door Kits

ORDERING INFORMATION

Blank Chassis Covers

Sc5_ManagedConnect_02_Quareo_v1.indd   7

12/12/12   10:38 AM

Tyco-catalog-AMP-2013-html.html
background image

5-8

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Managed Connectivity

Quareo

MANA

GED C

ONNE

C

TIVITY

SPECIFICATIONS

4200 PHYSICAL:

  Rack Mounting:

  

EIA/ETSI/WECO/IEC 60297 19-inch equipment racks

  Height in Rack:

  

1RU 44.5 mm, (1.75")

  Dimensions (HxWxD):

  

44.5 mm x 483 mm x 338 mm  (1.75" x 19" x 13.3") 

  Grounding:

 

2-screw grounding location for standard grounding lug

Q4400 PHYSICAL:

  Rack Mounting:

  

EIA/ETSI/WECO/IEC 60297 19-inch equipment racks

  Height in Rack:

  

2RU 88.9 mm, (3.5")

  Dimensions (HxWxD):

  

87.63 mm x 482.85 mm x 338 mm  (3.45" x 19" x 13.3") 

  Grounding:

  

2-screw grounding location for standard grounding lug

Q4800 PHYSICAL:

  Rack Mounting:

  

EIA/ETSI/WECO/IEC 60297 19-inch equipment racks

  Height in Rack:

  

4RU 177.8 mm, (7") 

  Dimensions (HxWxD):

  

177.8 mm x 483 mm x 338 mm  (7" x 19" x 13.3")

  Grounding:

  

2-screw grounding location for standard grounding lug

ENVIRONMENTAL:

  Operating Temperature:

  

-10 °C to +60° C (+14 °F to +140° F)

  Storage Temperature:

  

-40 °C to +85° C (-40°F to +185° F)

  Humidity:

  

5% to 95% non-condensing

 

 

RoHS Compliant

SAFETY: 

  Flammability:

 

(UL), c(UL), CE, A-TICK  

   

(UL) 94 V-0

 

 

UL 1863

EMC:   

 

 

EMC Directive, 2004/108/EEC

Sc5_ManagedConnect_02_Quareo_v1.indd   8

12/12/12   10:38 AM

Tyco-catalog-AMP-2013-html.html
background image

5-9

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Managed Connectivity

Quareo

MANA

GED C

ONNE

C

TIVITY

Product Description

Part Number

LC-to-LC Q4000 Chassis Blade;

 

fiber, 24 port duplex LC, 1/2 RU blade

Multimode (OM3/OM4)

QFB-48FDLCLMMHR

Singlemode

QFB-48FDLCLSMHR

LC-to-MPO Q4000 Chassis Blade;

 

fiber, 24 port duplex LC, 1/2 RU blade

Multimode (OM3/OM4); Loss 
(<0.5 dB) @ 850 nm/1300 nm

QFB-48FDLCMMMHR

Singlemode; Loss  
(<0.75 dB) @ 1310 nm/1550 nm)

QFB-48FDLCMSMHR

MPO-to-MPO Q4000 Chassis Blade;

 

fiber, 16 MPO Ports, 1/2 RU blade

Multimode (OM3/OM4)

QFB-192FMPOMMHR

Singlemode

QFB-192FMPOSMHR

Blades: LC-to-LC, LC-to-MPO, MPO-to-MPO

ORDERING INFORMATION

SPECIFICATIONS

PHYSICAL

  Dimensions (HxWxD):

  

19.3 mm x 438.4 mm x 373.1 mm (0.76” x 17.26" x 14.69”)

ENVIRONMENTAL

  Operating Temperature:

  

-10° C to +60° C (+14° F to +140° F)

  Storage Temperature:

  

-40° C to +85° C (-40° F to +185° F)

  Humidity:

  

5% to 95% non-condensing

ELECTRICAL

  Input Power:

  

1.0 W Max.

  Optical Interface
  MPO-to-MPO:

 

12 Fiber MPO

  LC-to-MPO:

 

Duplex LC (front), 12 Fiber MPO (rear)

  LC-to-LC:

 

Duplex LC

COMPLIANCE

   

RoHS Compliant

  Safety:

  

(UL), c(UL), CE, A-TICK

  Flammability:

  

(UL) 94 V-0   

   

UL 1863

  EMC:

 

EMC Directive, 2004/108/EEC

Sc5_ManagedConnect_02_Quareo_v1.indd   9

12/12/12   10:38 AM

Tyco-catalog-AMP-2013-html.html
background image

5-10

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Managed Connectivity

Quareo

MANA

GED C

ONNECTIVITY

Product Description

Part Number

QCC-4;

 Chassis Controller for Q4000 Network Chassis

QCPU-MCBM-1

QPWRS-USA: 

ASSY, Power Supply W/US Cord

QPWRS-USA

QCC-4 Chassis Controller   

COMPATIBLE WITH Q4000 NETWORK CHASSIS

 

 

 

FEATURES

•  Chassis controller (one per chassis) operates with the Q4000 series

•  Designed to fit with the rear of the chassis, does not require additional 

rack space

•  Power can be supplied through IEEE 802.3af compliant switch port 

(class 0) or auxiliary power supply (can be simultaneous)

Quareo Managed Fiber Cables   

MULTIMODE AND SINGLEMODE – MANAGED FIBER CABLES WITH CPID 

 

FEATURES

•  Standard lengths: 4, 7, 10, 15, 25 and 50 feet

•  Standard colors: Aqua for multimode, yellow for singlemode

•  Standard materials:   

– Plenum PVC (LSZH available upon request)

•  Performance specifications: ANSI/TIA-568-C.3 and ISO 11801,  

Edition 2 for OM3/OM4 multimode, OS1 for singlemode

Description

Fiber Type

Polarity

Part Number

LC-to-LC

  

Plenum

Multimode

OM3

A-to-A

QFPC-MPPM3PAxxxF

A-to-B

QFPC-MPPM3PBxxxF

OM4

A-to-A

QFPC-MPPM4PAxxxF

A-to-B

QFPC-MPPM4PBxxxF

SInglemode

A-to-A

QFPC-MKKSMPAxxxF

A-to-B

QFPC-MKKSMPBxxxF

Replace xxx with desired length in feet. Other materials available upon request.

ORDERING INFORMATION

ORDERING INFORMATION

Sc5_ManagedConnect_02_Quareo_v1.indd   10

12/12/12   10:38 AM

Tyco-catalog-AMP-2013-html.html
background image

5-11

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Managed Connectivity

Quareo

MANA

GED C

ONNE

C

TIVITY

Quareo Managed Trunk and Array Cables

ORDERING INFORMATION

Description

Fiber Type

Managed 

Cable 

Type

Connectors

Part Number

12 FIber

  

Plenum

Multimode

OM3

Array

MPO (Pinned/male)-LC

QFA-1MPM3PNxxxFAA

Trunk

LC-to-LC

QFA-1PPM3PNxxxFAA

MPO (no pins/female) to MPO (no pins/female)

QFA-1FFM3PNxxxFAA

OM4

Array

MPO (Pinned/male)-LC

QFA-1MPM4PNxxxFAA

Trunk

LC-to-LC

QFA-1PPM4PNxxxFAA

MPO (no pins/female) to MPO (no pins/female)

QFA-1FFM4PNxxxFAA

SInglemode

Array

MPO (Pinned/male)-LC

QFA-1RKSMPNxxxFAA

Trunk

LC-to-LC

QFA-1KKSMPNxxxFAA

MPO (no pins/female) to MPO (no pins/female)

QFA-1WWSMPNxxxFAA

24 FIber

  

Plenum

Multimode

OM3

Trunk

LC-to-LC

QFA-2PPM3PNxxxFAA;

MPO (no pins/female) to MPO (no pins/female)

QFA-2FFM3PNxxxFAA

OM4

Trunk

LC-to-LC

QFA-2PPM4PNxxxFAA

MPO (no pins/female) to MPO (no pins/female)

QFA-2FFM4PNxxxFAA

SInglemode

Trunk

LC-to-LC

QFA-2KKSMPNxxxFAA

MPO (no pins/female) to MPO (no pins/female)

QFA-2WWSMPNxxxFAA

48 FIber

  

Plenum

Multimode

OM3

Trunk

LC-to-LC

QFA-4PPM3PNxxxFAA

MPO (no pins/female) to MPO (no pins/female)

QFA-4FFM3PNxxxFAA

OM4

Trunk

LC-to-LC

QFA-4PPM4PNxxxFAA

MPO (no pins/female) to MPO (no pins/female)

QFA-4FFM4PNxxxFAA

SInglemode

Trunk

LC-to-LC

QFA-4KKSMPNxxxFAA

MPO (no pins/female) to MPO (no pins/female)

QFA-4WWSMPNxxxFAA

96 FIber

  

Plenum

Multimode

OM3

Trunk

LC-to-LC

QFA-8PPM3PNxxxFAA

MPO (no pins/female) to MPO (no pins/female)

QFA-8FFM3PNxxxFAA

OM4

Trunk

LC-to-LC

QFA-8PPM4PNxxxFAA

MPO (no pins/female) to MPO (no pins/female)

QFA-8FFM4PNxxxFAA

SInglemode

Trunk

LC-to-LC

QFA-8KKSMPNxxxFAA

MPO (no pins/female) to MPO (no pins/female)

QFA-8WWSMPNxxxFAA

Replace xxx with desired length in feet. Other materials available upon request.

Sc5_ManagedConnect_02_Quareo_v1.indd   11

12/12/12   10:38 AM

Tyco-catalog-AMP-2013-html.html
background image

5-12

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Managed Connectivity

Quareo

MANA

GED C

ONNE

C

TIVITY

SPECIFICATIONS FOR ARRAY CABLE: MEASURED THROUGH MPO MATED PAIR TO LC ADAPTER

Multimode (OM3, OM4) 
 

Insertion Loss (dB) 

 

850 nm 

1300 nm

 

  Maximum:

 

 

0.70 dB 

0.70 dB

 

  Typical:

 

 

0.25 dB 

0.4 dB

 

Return Loss (dB)

 

  Maximum:

 

 

-20 dB 

-20 dB

Singlemode
 

Insertion Loss (dB) 

 

1310 nm 

1550 nm

 

  Maximum:

 

 

1.0 dB 

1.0 dB

 

  Typical:

 

 

0.25 dB 

0.35 dB

 

Return Loss (dB)

 

  Minimum:

 

 

-55 dB 

-55 dB

SPECIFICATIONS FOR TRUNK CABLE : MPO-TO-MPO AND LC-TO-LC

Multimode (OM3, OM4) 
  Insertion Loss (dB) 

 

850 nm 

1310 nm

    Maximum:

 

 

0.70 dB 

0.70 dB

    Typical:

 

 

0.25 dB 

0.4 dB

  Return Loss (dB)
    Maximum:

 

 

-20 dB 

-20 dB

Singlemode
  Insertion Loss (dB) 

 

1310 nm 

1550 nm

    Maximum:

 

 

1.0 dB 

1.0 dB

    Typical:

 

 

0.25 dB 

0.35 dB

  Return Loss (dB)
    Minimum:

 

 

-55 dB 

-55 dB

Sc5_ManagedConnect_02_Quareo_v1.indd   12

12/12/12   10:38 AM

Tyco-catalog-AMP-2013-html.html
background image

5-13

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Managed Connectivity

Quareo

MANA

GED C

ONNE

C

TIVITY

Quareo Cross Connect Frame

The Quareo Cross-Connect Frame (Q-Frame) system provides the cable 
management necessary for the fiber intensive areas of today’s data centers. This 
innovative frame has eight 9" horizontal troughs for a total of 72" of horizontal 
trough space. This abundant trough space minimizes fiber pile up and congestion 
simplifying moves, adds and changes.

The frame system mounts to a standard 19-inch rack allowing the rear troughing 
system to line up between racks maximizing the routing between racks. The built-in 
patch cord storage panel will store up to 3.5 m (12') of patch cord slack and allows 
for the use of single patch cord length to connect any port within a single rack.

The Q-Frame is compatible with the Q4000 managed chassis, Q3000 
unmanaged chassis, RMG series 4RU chassis, and TFP series 4RU chassis and can 
accommodate 8 of either of these fiber panel products in a single frame.

The unique design of the Quareo Cross-Connect frame allows for any port within 
a single frame to be connected using a 6 m patch cord. As the line-up increases 
by a frame, the length to connect any port in the line-up increases by one meter. 
See table below for recommended fiber patch cord lengths for cross-connects in a 
continuous line-up. 
  
For more information on the Q-Frame, visit www.te.com/Qframe.

FEATURES 

Ample Trough Space

•  Reduces patch cord pile-up and congestion

 

 Reduces maintenance time due to easy removal and tracing of patch cords

 

 Minimizes risk of microbends or damage to fiber

•  Manages 3072 strands of LC and 24,576 of MPO for 100GbE

Built-in Patch cord Storage Panel

•  Simplifies frame installation

 

Saves money by reducing the number of different patch cord lengths that 
have to be kept in inventory

 

Minimizes risk of microbends or damage to fiber

•  Maintains fiber bend radius

•  Enclosed system ensures easy cable access without fiber cross-over points

Intuitive Cable Routing System

•  No fiber cross-over points

•  Multiple horizontal troughways

 

Reduces maintenance time due to easier removal and tracing of patch cords

•  Minimizes fiber “weaving”

Bend Radius Protection at Every Turn

•  Provides complete bend radius at every turn to ensure network performance 

and reliability

Sc5_ManagedConnect_02_Quareo_v1.indd   13

12/12/12   10:38 AM

Tyco-catalog-AMP-2013-html.html
background image

5-14

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Managed Connectivity

Quareo

MANA

GED C

ONNE

C

TIVITY

Number of 19-inch racks

1

Patch cord length

2

1

6 meters

2

7 meters

3

8 meters

4

9 meters

5

10 meters

6

11 meters

1

  Up to a maximum of ten racks

2

  Add one meter for each additional rack

Product Description

Part Number

Q-Frame 19-inch rack kit

Q-OFX-V

19-inch channel rack

ADCRACKBLK73

Left end guard kit

Q-OFX-GL

Right end guard kit

Q-OFX-GR

Cross-connect frame isolation pad kit

Q-IPCCM-KT

End guard isolation pad kit

Q-IPEG-KT

ORDERING INFORMATION

SPECIFICATIONS

MECHANICAL

Tower Dimensions (H x W x D):

 

84" x 40.7" x 23.9"

Weight (each tower):

 

90 lbs

End Guard Dimensions (H x W x D):

  84" x 3.5" x 23.9"

ENVIRONMENTAL

Operating Temperature:

 

14° F to 140° F

Relative Operating Humidity:

 

5 to 95 % 

   

(No condensation)

84.0"

(2132 mm)

23.9"

(608 mm)

40.7"

(1034 mm)

Front View

Side View

24213-A

*

*

– Add 3.25 inches (82.6 mm) when installing end guard.

* Add 3.25" (82.6 mm) when installing end guard.

Front View

Side View

Sc5_ManagedConnect_02_Quareo_v1.indd   14

12/12/12   10:38 AM

Tyco-catalog-AMP-2013-html.html
background image

5-15

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Managed Connectivity

Quareo

MANA

GED C

ONNE

C

TIVITY

Q2000 Series Network Panels

Q2000 Series Network Panels featuring Quareo Technology allow network 
personnel to view, manage and audit the physical layer. This means, for the 
first time, the physical layer is now subject to the same compliance policy 
as higher layers of the network. With 70% of network outages attributed to 
errors made in the physical layer, TE introduces a new category of products. 
Simply put, Quareo enables managed connectivity using connection point 
identification (CPID) technology.

FEATURES

•  Quareo enabled functionality with dual color port illumination (LED)

•  Integral cable management bar

•  45° IDC contacts providing secure, gas-tight connections

•  Accepts 110 style termination tools

•  Universal 568A/B wiring

•  Discrete labeling system

•  Maintenance services available on this product

QPC-2 Panel Controller Compatible with Q2000 Network Panels

FEATURES

•  Panel controller operates with the Q2000 family of Network Panels

•  Designed to fit inside the rear cable manager without interfering with panel 

connectivity, does not require additional rack space

•  Power can be supplied through IEEE 802.3af compliant switch port or additional 

auxiliary power supply (can be simultaneous)

•  Link and activity status LEDs at the rear of unit

•  Seamless power transition from PoE to aux supply

•  Maintenance services available on this product

Product Description

Part Number

Q2324 Network Panel; 

24 port (1RU) network panel with jacks

Cat 6A U/UTP

QCPP-24MC6AU

Cat 6A STP

QCPP-24MC6AS

Cat 6 U/UTP

QCPP-24MC6U

Q2348 Network Panel;

 48 port (2RU) network panel with jacks

Cat 6A U/UTP

QCPP-48MC6AU

Cat 6A STP

QCPP-48MC6AS

Cat 6 U/UTP

QCPP-48MC6U

QPC-2;

  Panel controller for Q2000 Network Panels

QCPU-MPPM-1

 

ORDERING INFORMATION

Sc5_ManagedConnect_02_Quareo_v1.indd   15

12/12/12   10:38 AM

Tyco-catalog-AMP-2013-html.html
background image

5-16

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Managed Connectivity

Quareo

MANA

GED C

ONNE

C

TIVITY

Q2324 PHYSICAL:

  Rack Mounting:

  

44.5 mm x 1.75 mm  (19" x 1RU)

Q2348 PHYSICAL:

  Rack Mounting:

  

88.9 mm, x 3.50 mm (19" x 2RU)

ENVIRONMENTAL:

  Operating temperature:

 

-40° to 70° C (104 to 158° F) 

  Number of plug insertions:

 

750 (IEC/EN 60603-7) 

DIAMETER RANGE:

  Solid and stranded copper conductors:

  

 26AWG to 22 AWG (0.4 mm dia to 0.6 mm dia) solid core cable 

and 24AWG stranded cable.

  Wire insulation diameter range:

 

1.04 mm to 1.60 mm  (0.041” x 0.063”)

  Insulation resistance:

 

at 40° C and 93% RH 

500 M

Ω

 

  Contact resistance:

 

1 m

Ω

 typical 

  Contact re-terminations:

 

200 

COMPLIANCE :

   

UL/CSA Approved, CE, A-TICK 

 

 

UL 94 V-0

 

 

UL186

 

 

RoHS compliant

 

 

Performance to ANSI/TIA-568-C.2 and ISO 11801, Edition 2 for  

 

 

Category 6/Class E and Category 6a/Class EA.  

 

 

Independently certified.

 

 

RJ socket, 8 positions FCC Part (IEC 60603-7)

 

SPECIFICATIONS

Product Dimensions (HxWxD):

 

21 mm x 143 mm x 105 mm (0.82" x 5.62" x 4.142")

Environmental:
  Operating Temperature:

 

-10° C to +60° C (+14° F to +140° F)

Compliance 
  Flammability:

 

(UL) 94 V-0

   

RoHS Compliant

 

 

UL/CSA Approved, CE, C-TICK

 

 

 Conformance with 8 way modular (RJ45) jack requirements according to IEC-
60603-7 series and TIA/EIA-968-A (FCC 68.500)

 

Alternate Input Power:

 

Alternate power source to comply with AC/DC desktop power supply brick

  Minimum requirements:

  

  Input Voltage:

  

100-240VAC, 50-60Hz, 0.5A

  Output Voltage:

  

48VDC, 0.4A

ELECTRICAL 

FUNCTION 

UNIT 

NOTES

Input Voltage:

 

36 – 56 

Volts 

PoE 37.5 – 56V

Input Current:

 

.200 

Amps 

Max current at 36V input

Output Voltage:

 

3.3VDC +/- 5% 

Volts 

Output Current:

 

3.5 

Amps 

Max Continuous

Efficiency:

 

85 

Peak Efficiency @48V input

Transition time PoE to AUX:

 

Seamless 

Sec 

Transition time AUX to PoE:

 

<30 

Sec 

Depends on PoE Power Supply

PoE Classification:

 

Class 0

Sc5_ManagedConnect_02_Quareo_v1.indd   16

12/12/12   10:38 AM

Tyco-catalog-AMP-2013-html.html
background image

6-1

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Fiber Cable Raceway FiberGuide ................................................6-3

Equipment Racks ..................................................................................6-18

Horizontal and Vertical Cable Management ..........................6-19

Cable Management Accessories ..................................................6-21

A cluttered cabling infrastructure is not an efficient one. 
Planning, mapping-out and meticulously managing your network 
is your best option to increase up-time and make moves, adds 
and changes easier. Our copper and fiber optic cabling, cable 
management systems, patch panels and enclosures help create 
reliable, high-speed data center connectivity even given limited 
space requirements. TE offers unique solutions for your tight 
spaces. From our fiber cable raceway systems and horizontal 
and vertical cable management options to equipment racks and 
accessories, TE has a cable management option for you.

Cable Management

Sc6_CableManagemet_v1.indd   1

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-3

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Fiber Cable Raceway FiberGuide Systems

TE's Fiber management systems offer the greatest breadth of optical raceway products in the industry. In response to 
customer requirements, TE continues to innovate and improve FiberGuide systems, adding greater flexibility and driving 
down installation time to ensure a smooth deployment.

FiberGuide is a raceway system designed to protect and route fiber optic patch cords, multi-fiber cable assemblies and 
intrafacility fiber cable (IFC) to and from fiber splice enclosures, fiber distribution frames and fiber optic terminal devices. 
FiberGuide ensures a two-inch minimum bend radius is maintained throughout the system. Tool-less, Snap-Fit junctions, 
cover options and Plenum Express Exit drops significantly reduce the amount of time required for installation.

4x12 Straight  

Section

4x12 Horizontal T

Express Exit

4x12 90° Horizontal Elbow

4x12 45° Down 

Elbow

Trumpet Flare

4x12 Horizontal 

Cross with two 6" 

Exits

4" Express Exit

4x6 Straight Section

4x12 Horizontal T with single 6" Exit

4x12 to 4x24 Adapter

4x24 Horizontal Cross

4x24 Straight Section

4x24 Island T with Single 12" Exit

4x4 Cut in T for 4x24 FiberGuide

4x24 45° Up Elbow

2x2 Horizontal 

Straight Section

2x2 90° Extended Horizontal Elbow

or 2x2 90° Horizontal Elbow

2x2 to 4x4 Adapter

4x4 90° Horizontal Elbow

4x6 45° Horizontal Elbow

Trumpet Flare

4x6 90° Down Elbow

Low Profile Express Exit

4x12 to Dual 4x6 Adapter

4x6 45° Down Elbow

4x6 45° Up Elbow with Cover

4x6 to 4x6 Adapter

4x6 90° Up Elbow 

with cover

4x6 Straight Section

4x6 Horizontal Cross

FEATURES

• 

Speed of Installation

FiberGuide systems feature a variety of products that allow for quick and easy installation. Express Exit drops as 
well as tool-less products including Snap-Fit junctions, snap-on covers and new hinged cover options save valuable 
time for installers

• 

Speed of Deployment

The Express Exit system enables new drops to be added or removed quickly and easily. A drop can be added into 

a fully loaded raceway in seconds – without cutting

• 

Raceway Flexibility

FiberGuide features 38 support structures, over 75 fittings, multiple drop options and several other components to 
suit any application you create

• 

Fiber Protection

TE's fiber expertise translates into maximum protection for your network. Two inch minimum bend radius is 

maintained throughout the system regardless of the raceway size

• 

Strength and Durability

100% raceway reliability – stands up to any challenge

Sc6_CableManagemet_v1.indd   3

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-4

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Express Exits Units 
(For use with 4x4, 4x6, 4x12 and 4x24 systems)

ORDERING INFORMATION

Description for Black Fiber Guide

Part Number

2" Express Exit Unit

FGSB-MEXP-A/B/F

4" Express Exit base with base cover

FGSB-MEXP-E-A/B/F

4" Express Exit rear cover kit

FGSB-MEXC-E-A/B/F

Rear cover, 4" Express Exit—4x4 system

FGSB-MEXC-E-A

Rear cover, 4" Express Exit—4x6 system

FGSB-MEXC-E-B

Rear cover, 4" Express Exit—4x12 system

FGSB-MEXC-E-F

Low profile Express Exit

FGSB-MEXP-LP-A/B/F

Express Exit

2x2 Fittings and Junctions

Description

Part Number

2x2 horizontal cross with cover

FGSB-MHXP-C

2x2 horizontal tee with cover

FGSB-MHTA-C

2x2 45

º

 horizontal elbow with cover

FGSB-MH4A-C

2x2 90

º

 horizontal elbow with cover

FGSB-MH9A-C

2x2 to 4" straight adapter with cover

FGSB-MDSA-AC

2x2 end cap kit (includes junction)

FGS-HMEC-C

2x2 45

º

 up elbow with cover

FGSB-MU4A-C

2x2 45

º 

down elbow with cover

FGSB-MD4A-C

2x2 90

º

 up elbow with cover

FGSB-MU9A-C

2x2 90

º

 down elbow with cover

FGSB-MD9A-C

2x2 junction

FGSB-MJWR-C

ORDERING INFORMATION

2x2 Straight Section

ORDERING INFORMATION

Description

Part Number

2x2 horizontal straight section with cover (6')

FGSB-MSHA-C

Sc6_CableManagemet_v1.indd   4

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-5

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

2x2 Downspout Options

ORDERING INFORMATION

Description

Part Number

2x2 standard downspout with cover

FGSB-MSDS-C

2x2 extended downspout with cover

FGSB-MDSP-C

2x2 flex tube attachment with 5' length 2" flex tube and 2x2 junction

FGSB-MEX1-C-5F

2x2 extended downspout kit with 2' length 2" flex tube and cover

FGSB-KDH2-C

Dual 

7

/

8

" flex tube attachment with (2) 5' lengths flex tube and  

2x2 junction

FGSB-KT03-C 

Kit of ten 

7

/

8

" flex tube clamps

FGS-HSHS-C

2x2 Direct Support Kits

ORDERING INFORMATION

Description

Part Number

2x2 ladder rack support kit

FGS-HLR2-C

2x2 bay top short L bracket kit

FGS-BTBS-C

2x2 bay top long L bracket kit

FGS-BTBL-C

2x2 digital cableway support kit

FGS-HDCB-C

2x2 underfloor support kit

FGS-HUFB-C

2x2 Track Support Kits

ORDERING INFORMATION

Description

Part Number

2x2 aluminum track support kit (6')

FGS-HASK-C

New threaded rod kit (

5

/

8

")

FGS-HTR2-5/8

New threaded rod kit (

1

/

2

")

FGS-HTR2-1/2

2x2 track connecting bar kit

FGS-HAEJ-C

Ladder rack bracket kit (

5

/

8

")

FGS-HLDR-5/8

Threaded rod 12" long

FGS-HTHR-5/8-12

Dual threaded rod bracket kit

FGS-HTUB-2-AB

2x2 Aluminum Track 

Support Kit

FGS-HASK-C

Sc6_CableManagemet_v1.indd   5

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-6

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

2x6 Fittings

ORDERING INFORMATION

Description

Part Number

2x6 to 2x2 downspout

FGSB-MDSP-G

2x6 horizontal T

FGSB-MHRT-G

2x6 horizontal cross

FGSB-MHXP-G

2x6 90

º

 horizontal elbow

FGSB-MH9E-G

2x6 90

º

 down elbow

FGSB-MD9E-G

2x6 45

º

 horizontal elbow

FGSB-MH4E-G

2x6 45

º

 up elbow with cover

FGSB-MU4E-G

2x6 45

º

 down elbow

FGSB-MD4E-G

2x6 to 4x4 adapter

FGSB-MDSA-GA

2x6 to 4x6 adapter

FGSB-MDSA-GB

2x6 trumpet flare

FGSB-MTRM-G

2x6 end cap

FGS-HMEC-G1

2x6 Express Exit

FGSB-MEXP-LP-G

2x6 Straight Section

ORDERING INFORMATION

Description

Part Number 

2x6 horizontal straight section 

6'

FGSB-MSHS-G

Hinged cover

FGSB-MSNC-B/G

2x6 junction

FGSB-JUNC-G

Sc6_CableManagemet_v1.indd   6

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-7

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

4x4 Fittings and Junctions

ORDERING INFORMATION

Description

Part Number

4x4 downspout

FGSB-MDSP-A

4x4 and 4x6 downspout cover

FGSB-MCDS-AB

4x4 extended downspout

FGSB-MDSP-EX-A

4x4 and 4x6 extended downspout cover

FGSB-MCDS-EX-AB

4x4 horizontal T

FGSB-MHRT-A

4x4 horizontal T cover

FGSB-SHRT-A

4x4 horizontal cross

FGSB-MHXP-A

4x4 horizontal cross cover

FGSB-SHXP-A

4x4 90

º

 horizontal elbow

FGSB-MH9E-A

4x4 90

º

 horizontal elbow cover

FGSB-SH9E-A

4x4 45

º

 horizontal elbow

FGSB-MH4E-A

4x4 45

º

 horizontal elbow cover

FGSB-SH4E-A

4x4 90

º

 up elbow with cover

FGSB-MU9E-A

4x4 90

º

 down elbow

FGSB-MD9E-A

4x4 90

º

 down elbow cover

FGSB-SD9E-A

4x4 45

º

 up elbow with cover

FGSB-MU4E-A

4x4 45

º

 down elbow

FGSB-MD4E-A

4x4 45

º

 down elbow cover

FGSB-SD4E-A

4x4 to 4x6 straight adapter

FGSB-MDSA-AB

4x4 to 4x6 straight adapter cover

FGSB-SDSA-AB

4x4 end cap

FGS-HMEC-A

4x4 Snap-Fit junction

FGSB-MFAW-A

4x4 cut-in T

FGSB-MHIS-A

Cut-in T fixture

FGS-MHIS-JIG-A/B/F

4x4 IFC tie bracket

FGS-HIFC-A

4x4 Straight Section

ORDERING INFORMATION

Description

Part Number

4x4 horizontal straight section (6')

FGSB-MSHS-A

4x4 horizontal straight section hinged cover (6')

FGSB-MSHC-A

4x4 expandable straight section

FGSB-MVAR-A

4x4 Snap-Fit Junction

FGSB-MFAW-A

Sc6_CableManagemet_v1.indd   7

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-8

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

4x4 and 4x6 Downspout Options

ORDERING INFORMATION

Description

Part Number

4x4 downspout junction kit

FGSB-MJWR-A

2x2 flex tube attachment with 5' length 2" flex tube and 2x2 junction

FGSB-MEX1-C-5F

4x4/4x6 downspout insert (adapts to 2x2 system)

FGS-HDSI-AB

4x4 trumpet flare kit

FGSB-MTRM-A

4" square to 2" round adapter with 5' flex tubing

FGSB-ASRI-5F

4" square to 2" round adapter with 10' flex tubing

FGSB-ASRI-10F

4" square to 2" round adapter with 15' flex tubing

FGSB-ASRI-15F

4x4 single flex tube attachment with (1) 5'  length 2" flex tubing

FGSB-KT03-A

4x4 dual flex tube attachment with (2) 5' lengths 2" flex tubing

FGSB-KT03-A

2x6, 4x4 and 4x6 Support Kits

ORDERING INFORMATION

Description

Part Number 

New threaded rod bracket (

5

/

8

")

FGS-HNTR-5/8

New threaded rod bracket (

1

/

2

")

FGS-HNTR-1/2

Modified new threaded rod bracket (

5

/

8

")

FGS-HNTR-5/8-A

Existing threaded rod bracket (

5

/

8

")

FGS-HETR-5/8

Existing threaded rod bracket (

1

/

2

")

FGS-HETR-1/2

Modified existing threaded rod bracket (

5

/

8

")

FGS-HETR-5/8-A

Center support bracket (

5

/

8

")

FGS-HTUB-5/8

Center support bracket (

1

/

2

")

FGS-HTUB-1/2

L bay support bracket

FGS-HLBK

Digital cableway bracket kit (12")

FGS-HCBL-12

Digital cableway bracket kit (15")

FGS-HCBL-15

Top support C-bracket

FGS-HNTS-5/8

Top support low profile C-bracket

FGS-HNTS-5/8-LP

Ladder rack center support bracket kit

FGS-HNLR-AB

Threaded rod, 

5

/

8

-11x12"

FGS-HTHR-5/8-12

Threaded rod, 

5

/

8

-11x30"

FGS-HTHR-5/8-30

Threaded rod, 

5

/

8

-11x72"

FGS-HTHR-5/8-30

Auxiliary framing clip kit 

5

/

8

-11 thread

FGS-HTHR-5/8-72

Auxiliary framing clip kit 

1

/

2

-11 thread

FGS-HFCK-5/8

Adjacent angle support bracket 

5

/

8

-11/36"

FGS-HFCK-1/2

Adjacent angle support bracket 

5

/

8

-11/48"

FGS-HASB-5/8-36

Adjacent angle support bracket 

1

/

2

-13/36"

FGS-HASB-5/8-48

Adjacent angle support bracket 

1

/

2

-13/36"

FGS-HASB-1/2-36

Adjacent angle support bracket 

1

/

2

-13/48"

FGS-HASB-1/2-48

Ladder rack bracket kit (

5

/

8

")

FGS-HLDR-5/8

Unistrut nut kit (

5

/

8

")

FGS-HDGR

Sc6_CableManagemet_v1.indd   8

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-9

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

FGSB-MFAW-B

FGSB-MH9E-B

4x6 Fittings and Junctions

ORDERING INFORMATION

Description

Part Number 

4x6 downspout

FGSB-MDSP-B

4x4/4x6 downspout cover

FGSB-MCDS-AB

4x6 extended downspout

FGSB-MDSP-EX-B

4x4/4x6 extended downspout cover

FGSB-MCDS-EX-AB

1

4x6 horizontal T

FGSB-MHRT-B

4x6 horizontal T cover

FGSB-SHRT-B

4x6 horizontal cross

FGSB-MHXP-B

4x6 horizontal cross cover

FGSB-SHXP-B

4x6 90

º

 horizontal elbow

FGSB-MH9E-B

4x6 90

º

 horizontal elbow cover

FGSB-SH9E-B

4x6 45

º

 horizontal elbow

FGSB-MH4E-B

4x6 45

º

 horizontal elbow cover

FGSB-SH4E-B

4x6 45

º

 up elbow with cover

FGSB-MU4E-B

4x6 45

º

 down elbow

FGSB-MU4E-B

4x6 45

º

 down elbow cover

FGSB-MD4E-B

4x6 90

º

 down elbow

FGSB-SD4E-B

4x6 90

º

 down elbow cover

FGSB-MD9E-B

4x6 90

º

 up elbow with cover

FGSB-SD9E-B

4x6 cut-in T

FGSB-MHIS-B

Cut-in T fixture

FGS-MHIS-JIG-A/B/F

4x6 trumpet flare kit

FGSB-MTRM-B

4x6 end cap

FGS-HMEC-B

4x6 Snap-Fit junction

FGSB-MFAW-B

4x6 IFC tie bracket

FGS-HIFC-B

4x6 Trumpet Flare Kit

4x6 90° Horizontal Elbow

4x6 Snap-Fit Junction

6' Horizontal Straight Section

FGSB-MTRM-B

1

Dual downspout requires 2 covers.

FGS-MSHS-B

4x6 Straight Section

ORDERING INFORMATION

Description

Part Number 

6' horizontal straight section

FGSB-MSHS-B

6' horizontal straight section hinged cover

FGSB-MSHC-B

4x6 expandable straight section

FGSB-MVAR-B

Sc6_CableManagemet_v1.indd   9

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-10

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

4x12 Straight Section

ORDERING INFORMATION

Description

Part Number

6' horizontal straight section

FGSB-MSHS-F

4x12 expandable straight section

FGSB-MVAR-F

6' hinged cover

FGSB-MSNC-F

4x12 Junction

ORDERING INFORMATION

Description

Part Number

4x12 snap fit junction

FGSB-MFAW-F

4x12 to 4x6 Adapter

4x12 Trumpet Flare Kit

FGSB-MDSA-FB

FGSB-MTRM-F

4x12 Fittings

ORDERING INFORMATION

Description

Part Number

4x12 horizontal T

FGSB-MHRT-F

4x12 to 4x6 horizontal T

FGSB-MHRT-F/B

4x12 horizontal cross

FGSB-MHXP-F

4x12 to 4x6 horizontal cross

FGSB-MHXP-B/F

4x12 to 4x6 adapter

FGSB-MDSA-FB

4x12 90

º

 horizontal elbow

FGSB-MH9E-F

4x12 45

º

 horizontal elbow

FGSB-MH4E-F

4x12 end cap

FGS-HMEC-F

4x12 cut-in T

FGSB-MHIS-F

Cut-in T fixture

FGS-MHIS-JIG-A/B/F1

4x12 45

º

 up elbow with cover

FGSB-MU4E-F

4x12 45

º

 down elbow

FGSB-MD4E-F

4x12 90

º

 down elbow

FGSB-MD9E-F

4x12 trumpet flare kit

FGSB-MTRM-F

4x12 downspout with 4x6 exit

FGSB-MDSP-F

4x12 downspout with rear T

FGSB-MDRT-F

4x12 to dual 4x6 adapter

FGSB-MDSA-F2B

4x12 IFC tie bracket

FGS-HIFC-F

Note: Covers are available for 4x12 fittings. Please contact TE or visit www.TE.com/EnterpriseNetworks

Sc6_CableManagemet_v1.indd   10

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-11

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

4x12 System Support Kits

ORDERING INFORMATION

Description

Part Number

New threaded rod bracket (

5

/

8

")

FGS-HNTR-F-5/8

Existing threaded rod bracket (

5

/

8

")

FGS-HETR-F-5/8

Top support threaded rod bracket kit

FGS-HNTS-F-5/8

Top support low profile threaded rod bracket kit

FGS-HNTS-F-5/8-LP

Trapeze bracket kit

FGS-HNTP-F-5/8

Ladder rack center support bracket kit

FGS-HNLR-F

Vertical Duct Systems

ORDERING INFORMATION

Description

Part Number

2x2 vertical slotted duct kit, 6'

FGSB-KTW1-C

2x2 vertical 1.5-inch slotted duct kit, 6'

FGSB-KTW1-CA

2x2 vertical solid duct

FGSB-KTW4-C

1x2 vertical duct kit

FGSB-KTW1-E

1x2 solid vertical duct kit

FGSB-KTW4-E

2x2 vertical to 1x2 vertical adapter bracket

FGSB-ACC063

2x2 vertical slotted duct, 6'

FGSB-MSHS-C

2x2 vertical 1.5" slotted duct, 6'

FGSB-MSHS-CA

Cover for 2x2 vertical duct, 6'

FGSB-MSHC-C

2x2 vertical duct mounting bracket

FGS-HWMB-C

1

4x4 vertical duct kit

FGSB-KTW2-D

4x4 vertical adapter junction kit

FGSB-MJWR-D

4x4 vertical slotted duct, 6'

FGSB-MSHS-D

Cover for 4x4 vertical duct, 6'

FGSB-MSHC-D

4x4 vertical duct mounting bracket

FGS-HWMB-D

Sc6_CableManagemet_v1.indd   11

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-12

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Fiber Cable Raceway Accessories

ORDERING INFORMATION

Description

Part Number

Flex Tubing

   2" outer diameter slotted flex tube, 5'

FGSB-MIDY-5F

   2" outer diameter slotted flex tube, 10'

FGSB-MIDY-10F

   2" outer diameter slotted flex tube, 15'

FGSB-MIDY-15F

   1" outer diameter slotted flex tube, 100'

FGSB-MLDY-100F

   1" outer diameter slotted flex tube, 150'

FGSB-MLDY-150F

   1" outer diameter slotted flex tube, 200'

FGSB-MLDY-200F

   1" outer diameter slotted flex tube, 250'

FGSB-MLDY-250F

   

7

/

8

" outer diameter slotted flex tube, 5'

FGSB-MFTY-5F

   

7

/

8

" outer diameter slotted flex tube, 10'

FGSB-MFTY-10F

   

7

/

8

" outer diameter slotted flex tube, 15'

FGSB-MFTY-15F

   

7

/

8

" outer diameter slotted flex tube, 200'

FGSB-MFTY-200F

Accessories

   Hinge kit for 4x4 and 4x6 covers (kit of 1)

FGS-HHGK

   Self-closing hinge (kit of 3)

FGS-HVHG

   Retainer rings (kit of 10)

FGS-HFRR-10

   Trough cover clip kit

FGS-KT09

   Mitre box and saw

FGS-MKIT-ABF

   Quick knobs (10)

FGS-KQKB

   Quick knobs (100)

FGS-HQKK

   Flex tube clamps (kit of 10)

FGS-HHEC-10

2" Outer Diameter Slotted Flex Tube 

(FGS-MIDY)

7

/

8

" Outer Diameter Slotted Flex Tube 

(FGS-MFTY)

Retainer Rings

(FGS-HFRR-101)

Flex Tube Clamp  

(FGS--HHEC-101)

Quick-Knobs - Kit of 10  

(FGS-KQKB)

Sc6_CableManagemet_v1.indd   12

12/14/12   11:54 AM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-13

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

The Snap-Fit junction assembly is available for the 24" FiberGuide system. The 
Snap-Fit junction is a completely tool-less junction. No additional tools are required 
for installation or removal. The junction exhibits superior holding force and 
accommodates support brackets. A warning label is included with each junction kit.

The unique double wall channel design of the 4x24 straight section provides 
exceptional strength and durability for high fiber count applications and allows 
the standard system to be attached to the support structure without the need to 
cut or drill any holes within the trough. The six channel design ensures that the 
patch cords will not come in contact with any screw heads or bolts, an important 
consideration in 4x24 systems where higher cable counts apply increased pressure 
on patch cords at the bottom of the trough.

Description

Part Number

4x24 straight section; 

horizontal straight section, 6' long

FGSB-MSHS-H

Description

Part Number

4x24 Snap-Fit junction 

FGSB-MFAW-H

4x24 System – Straight Section

4x24 Snap-Fit Junction

ORDERING INFORMATION

ORDERING INFORMATION

Sc6_CableManagemet_v1.indd   13

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-14

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

4x24 System Fittings – 4" H x 24" W

Description

Part Number

4x24 fittings

   45° horizontal elbow

FGSB-MH4E-H

   Horizontal T with single 12" exit

FGSB-MHRT-H/F

   Horizontal T with three 24" exits

FGSB-MHRT-H

   Horizontal cross

FGSB-MHXP-H

   Horizontal cross with dual 12" exits

FGSB-MHXP-F/H

   45° up elbow

FGSB-MU4E-H

   45° down elbow

FGSB-MD4E-H

4x24 conversions

   12" cut-in T for 4x24

1

FGSB-MHIS-F/H

   6" cut-in T for 4x24

1

FGSB-MHIS-B/H

   4" cut-in T for 4x24

1

FGSB-MHIS-A/H

   4x24 to 4x12 adapter

FGSB-MDSA-HF

4x24 end cap

FGS-HMEC-H

End Cap 

(FGS-HMEC-H)

ORDERING INFORMATION

4x24 System Downspouts – 4" H x 24" W

Description

Part Number

Island T with single 12" exit 

FGSB-ISLAND-H/F

Trumpet flare

FGS-MTRM-H

ORDERING INFORMATION

4x24 downspouts and attachments feed fiber from overhead straight sections into 
fiber optic equipment below.

Trumpet Flare

(FGS-MTRM-H)

1

 Designed exclusively for the 4x24" system

Sc6_CableManagemet_v1.indd   14

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-15

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13 313948AE

CABLE MANA

GEMENT

12.7 mm

(.5")

736.6 mm

(29")

844.6 mm

(33.25")

50.8 mm

(2")

Split Nut

Bracket 

Clip

Existing Threaded Rod Trapeze Bracket

Threaded Rod Ref

Quick Knob

Existing 5/8” Threaded Rod Trapeze Bracket Kit

(FGS- HETP-H-5/8)

793.8 mm

(31.25")

736.6 mm

(29")

50.8 mm

(2")

New 5/8” Threaded Rod Trapeze Bracket Kit

(FGS-HNTP-H-5/8)

Variable Support Bracket - Horiz. Elbow 

(FGS-MH4E-H-VS)

Variable Support Bracket - Horiz. T 

(FGS-MHRT-H/F-VS)

Variable Support Bracket - Horiz. Cross

(FGS-MHXP-F/H-VS)

Variable Support Bracket - Horiz. Cross 

(FGS-MHXP-H-VS)

4x24 System Support Kits

Variable Fitting Support Locator Kit 

– Horizontal Elbow

(FGS-MH4E-H-VS)

Variable Fitting Support Locater Kit –

Horizontal T with Single 12" Exit

(FGS-MHRT-H/F-VS)

Variable Fitting Support Locater 

Kit – Horizontal Cross

(FGS-MHXP-H-VS)

Variable Fitting Support Locater Kit – 

Horizontal Cross with Dual 12" Exits

(FGS-MHXP-F/H-VS)

New 5/8" Threaded Rod Trapeze Bracket Kit

(FGS-HNTP-H-5/8)

Existing 5/8" Threaded Rod Trapeze Bracket Kit

(FGS- HETP-H-5/8)

Description

Part Number

4x24 System Support Kits

Variable fitting support locater kit for

     Horizontal elbow

FGS-MH4E-H-VS

     Horizontal T with single 12" exit

FGS-MHRT-H/F-VS

     Horizontal cross

FGS-MHXP-H-VS

     Horizontal cross with dual 12" exits

FGS-MHXP-F/H-VS

Threaded rod trapeze bracket kit for

     Existing; 

5

/

8

"

FGS-HETP-H-5/8

     New; 

5

/

8

"

FGS-HNTP-H-5/8

ORDERING INFORMATION

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-16

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Recommended • maximum density

Recommended capacity takes into consideration random patch cord placement 
into the FiberGuide system. Maximum density refers to the maximum number 
of fiber patch cords in a given cross-section of a FiberGuide installation. The 
TracerLight connector identification system is TE's newest patch cord solution. It 
features slightly different dimensions than standard patch cords.

SPECIFICATIONS

1.7 mm 

Patch Cords (per in

2

)

2.0 mm 

Patch Cords (per in

2

)

3.0 mm 

Patch Cords (per in

2

)

120/142

90/102

40/44

tRough PileuP • Recommended/maximum density

2-inch

3-inch

4-inch

4x24 system

   1.7 mm

5760/6816

8640/10224

11520/13632

   2.0 mm

4320/4869

6480/7344

8640/9792

   3.0 mm

1920/2112

2880/3168

3840/4224

4x12 System

   1.7 mm

2880/3408

4320/5112

5760/6816

   2.0 mm

2160/2448

3240/3672

4320/4896

   3.0 mm

960/960

1440/1584

1920/2112

4x6 System

   1.7 mm

1440/1704

2160/2556

2880/3408

   2.0 mm

1080/1224

1620/1836

2160/2448

   3.0 mm

480/528

720/792

960/1056

4x4 System

   1.7 mm

960/1136

1440/1704

1920/2272

   2.0 mm

720/816

1080/1224

1440/1632

   3.0 mm

320/352

480/528

640/704

2x6 System

   1.7 mm

1440/1740

   2.0 mm

1080/1224

   3.0 mm

480/528

2x2 System

   1.7 mm

480/568

   2.0 mm

360/408

   3.0 mm

160/176

Sc6_CableManagemet_v1.indd   16

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Fiber Cable Raceway FiberGuide

6-17

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

TRACERLIGHT PATCH CORDS—65 PATCH CORDS PER INCH 

2-inch

3-inch

4-inch

4x24 System

3120

4680

6420

4x12 system

1560

2340

3120

4x6 System

780

1170

1560

4x4 System

520

780

1040

2x6 System

780

2x2 System

260

Raw Material Meets UL Requirement

Finished Product Meets UL Requirement

FiberGuide Straight Sections (All FiberGuide Systems)

Flame rated: UL94V-0

UL94V-0 and UL2024

FiberGuide Molded Fittings (All FiberGuide Systems)

Flame rated: UL94V-0

UL94V-0 and UL2024

FiberGuide Flex Tube (2")

Flame rated: UL94V-0

UL2024

FiberGuide Flex Tube (1")

Flame rated: UL94V-0

UL2024

FiberGuide Flex Tube (7/8")

Flame rated: UL94V-2

UL2024

Note: FiberGuide flex tube complies with the National Electrical Code (NEC) Article 770-51 and Underwriters Laboratory UL2024 requirements for 
general purpose fiber optic raceways.

FiberGuide Materials Product Statement

The FiberGuide fiber management system is a UL-listed (E151158) general purpose fiber optic raceway system. All FiberGuide 
products are manufactured from flame-retardant materials. No FiberGuide system parts contain PVC. The table summarizes 
the fire-resistant properties of FiberGuide straight sections, molded parts and flex tube.

Sc6_CableManagemet_v1.indd   17

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Equipment Racks

6-18

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Equipment Racks

TE Connectivity offers a variety of rack options with two and four post racks to
support enterprise network solutions in todays moden IT infrastructure. All racks
are designed of high quality materials and construction to meet TIA, EIA and IEEE
requirements. Each rack features mounting hole patterns per EIA-310-E standards.

FEATURES

• 

Available in two and four post designs

• 

Made of 6061-T6 aluminum alloy

• 

Flat black powder coat finish

• 

Features pre-tapped #12-24 mounting holes

• 

Shipped unassembled with all components and instructions required to
assemble a fully functional rack

• 

Feature double sided, EIA universal rails with 0.625" (16 mm),
0.625" (16 mm), 0.5" (13 mm) mounting spaces

• 

Three inch deep, two post rack features include:

Universal junction hole pattern

Conformance to EIA-310-E

• 

Two post, high capacity network equipment racks offer increased cable
capacity over standard racks. Features include:

Large vertical cable duct for increased cable capacity and D-rings for
out-of-the-box cable management

Large side cable pass-thru holes for rack-to-rack cabling

 Adjustable waterfalls on top cable management trays

Top angles with pre-drilled mounting holes for runway attachment

Can be assembled for either 19" or 23" equipment

• 

Four post network equipment racks offer stability, accessibility and open
cooling with industry standard features. Features include:

Nearly 360° of access – completely open to allow excess heat from
equipment to quickly dissipate

Stamped, RMU (rack mount unit) markings conform to EIA-310-E

Description

Channel Depth

Width (inches)

Height RMU (inches) Figure Part Number

2 Post Rack

3"

19

45 (84)

A

1933559-1

2 Post Rack with Vertical Cable Management

6"

19 or 23

45 (84)

B

1933560-1

4 Post Rack

3"

19

45 (84)

C

1933570-1

ORDERING INFORMATION

Figure A

Figure B

Figure C

Sc6_CableManagemet_v1.indd   18

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

6-19

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Cable Management

Horizontal and Vertical Cable Management

ORDERING INFORMATION

Horizontal High-Density Cable Management

FEATURES

• 

Snap-on removable hinged door remains open past 180°

• 

#12-24 mounting hardware is included

• 

Flat black powder coat aluminum with UL 94V-0 black plastic components

• 

Standard fingers are 5.5" deep

Part Number

Rack Mount Units (Height)

Width

Finger Type

Single Sided

Double Sided

1RU

19"

Standard Fingers

1933530-1

1933531-1

2RU

19"

Standard Fingers
Extended Fingers

1933532-1
1933566-1

1933533-1
1933567-1

3RU

19"

Standard Fingers

1933561-1

1933562-1

 

Single Sided

 

Double Sided

ORDERING INFORMATION

Description

Part Number

Stationary, Ventilated Shelf for Standard 19-inch Racks

1435049-1

Stationary, Ventilated Shelf

FEATURES

• 

Ventilation slots easily allow air flow

• 

Requires 2RU (3.50")

• 

Fits standard 19-inch racks

• 

Includes fastening hardware

Sc6_CableManagemet_v1.indd   19

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Horizontal and Vertical Cable Management

6-20

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Cable Management

Horizontal and Vertical Cable Management

ORDERING INFORMATION

Double-Sided High-Density Vertical Cable Managers

FEATURES

• 

Standard fingers are spaced 1RU vertically and are 8.5" deep

• 

Gates have 9RU vertical spacing and are 8.5" deep

• 

Two-piece doors with snap on hinges allow for quick opening from either
side or complete removal

• 

Six snap-on gates retain cables when doors are opened or removed

• 

Easy installation, can be done in minutes using standard hand tools

• 

Works with EIA-310-E compliant two and four post equipment racks using
industry standard mounting holes

• 

1/4" accessory mounting holes run the full height on both sides of cable
manager to accommodate the attachment of cable management accessories

• 

Separator panel with pass through openings, vertical slots for attaching
straps and keyhole slots for attaching spools, included with each manager

• 

Front and rear vertical sections can be spaced apart when mounting on racks
deeper than 3" (76 mm)

• 

Flat black powder coat aluminum with UL 94V-0 black plastic components

• 

Vertical cable managers include:

Front and Rear vertical cabling section, (4) doors, (6) gates, (50) push-in
fasteners, (12) cable strap mounts, Separator panel and mounting hardware

On 10" and 12" wide cable managers only: (2) spool kits are included

Figure A

Part Number

Description

Figure

Front/Rear duct type

6"Width

10" Width

12" Width

High-Density Vertical Cable 
Manager, 84", Double-sided

A

Standard Fingers/ 

Standard Fingers

1933534-1

1933535-1

1933536-1

High-Density Combination Vertical 
Cable manager, 84", Double-sided

B

Standard Fingers/Gates

1933540-1

1933541-1

1933542-1

Figure B

Sc6_CableManagemet_v1.indd   20

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

6-21

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Part Number

Description

Figure

Front/Rear duct type

6"Width

10" Width

12" Width

High-Density Vertical Cable 
Manager, 84", Double-sided

A

Standard Fingers/ 

Standard Fingers

1933534-1

1933535-1

1933536-1

High-Density Combination Vertical 
Cable manager, 84", Double-sided

B

Standard Fingers/Gates

1933540-1

1933541-1

1933542-1

Cable Management

Cable Management Accessories

High-Density Cable Management Accessories 

FEATURES

• 

Replacement door kits:

 

Include an upper and lower door section

 

Are for use with high-density double-sided and double-sided combination 
vertical cable managers

• 

Finger brackets (Figure A):

 

High-density finger bracket mounts directly to a relay rack and provides 
cable support at each rack mounting unit

 

 Fingers align with rack mounting units

 

 Includes (1) finger bracket and mounting hardware

 

 Flat black powder coat aluminum bracket with UL 94V-0 black plastic 
finger section

• 

Cable spools (Figure B):

 

Provide 1.1" (28 mm) bend radius

 

 Cable spools attach quickly to keyhole slots provided in mounting channels 
and optional back covers 

 

 Facilitates storage and routing of cable

 

 Unique spool kit design provides for vertical and horizontal adjustability to 
suit any need

 

 Spool kits includes (2) spools, mounting channels and hardware

 

 Flat black powder coat steel with UL 94V-0 black plastic

• 

Fasteners (Figure C):

 

Used to quickly attach accessories to 1/4" (6 mm) mounting holes in  
cable manager

 

 Can be easily removed for relocation

 

 Standard pack: 100 pieces

 

 Black plastic UL 94V-2

• 

Cable strap mounts (Figure D):

 

 Provides attachment for cable straps up to 3/4" (19 mm) wide

 

 Attach with push-in fastener 1933554-1 to 1/4" (6 mm) accessory mounting 
holes in cable manager

 

Standard pack: 100 pieces

 

Black plastic UL 94V-0

Description

Figure

Part Number

6" Width

10" Width

12" Width

Replacement Door Kits

1933556-1

1933557-1

1933558-1

Part Number

Finger Bracket

A

1933552-1

Cable Spools

B

1933553-1

Fasteners

C

1933554-1

Cable Strap Mounts

D

1933555-1

ORDERING INFORMATION

Figure A

Figure B

Figure C

Figure D

Sc6_CableManagemet_v1.indd   21

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-22

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Cable Management

Cable Management Accessories

Horizontal Finger Duct Panels and Accessories

FEATURES

• 

Cable management accessories for EIA standard 19-inch equipment racks

• 

Suitable for high-performance twisted pair and optical fiber distribution
cables and patch cords

• 

Horizontal finger duct panels available in single and double-sided versions

• 

Extended covers bridge the gap between finger duct and vertical
cable management

Figure A - Standard Cover

Figure B - Standard Cover

Part Number

Description

Panel Height Front (HxD) Rear (HxD)

Figure

Standard Covers

Extended Covers

Cable Management Panel

Single Sided

1RU (1.75")

1."5 x 2"

1375161-1

1375161-2

1.5" x 3"

1375162-1

1375162-2

2RU (3.50")

3.0" x 3"

A

1375163-1

1375163-2

Double Sided

1RU (1.75")

1.5" x 2"

1" x 4"

1375160-1

1375160-2

1.5" x 3"

1" x 4"

1375159-1

1375159-2

2RU (3.50")

3.0" x 3"

2" x 4"

B

1375158-1

1375158-2

Front Replacement Covers

1RU (1.75")

1479225-1

1479225-2

2RU (3.50")

1479222-1

1479222-2

Rear Replacement Covers

1RU (1.75")

1479224-1

2RU (3.50")

1479223-1

ORDERING INFORMATION

Vertical Finger Duct Panels

FEATURES

• 

Cable management accessories for EIA standard 19-inch equipment racks

• 

Suitable for high-performance twisted pair and optical fiber distribution cables and
patch cords

• 

Vertical finger duct panels available in single and double-sided versions

• 

Center mount vertical finger duct panels mount between racks for added stability

Description

Mounting Position

Panel Height

Front (W x D)

Rear (W x D)

Figure

Part Number

Single-Sided

Side Mount

35"

4" x 5"

A

1375165-1

78"

4" x 5"

1375258-1

Center Mount

35"

4" x 5"

B

1375167-1

78"

4" x 5"

1375260-1

Double-Sided

Side Mount

35"

4" x 5"

4" x 5"

A

1375164-1

78"

4" x 5"

4" x 5"

1375257-1

Center Mount

35"

4" x 5"

4" x 5"

B

1375166-1

78"

4" x 5"

4" x 5"

1375259-1

Figure A

Figure B

ORDERING INFORMATION

Sc6_CableManagemet_v1.indd   22

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-23

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GEMENT

Part Number

Description

Panel Height Front (HxD) Rear (HxD)

Figure

Standard Covers

Extended Covers

Cable Management Panel

Single Sided

1RU (1.75")

1."5 x 2"

1375161-1

1375161-2

1.5" x 3"

1375162-1

1375162-2

2RU (3.50")

3.0" x 3"

A

1375163-1

1375163-2

Double Sided

1RU (1.75")

1.5" x 2"

1" x 4"

1375160-1

1375160-2

1.5" x 3"

1" x 4"

1375159-1

1375159-2

2RU (3.50")

3.0" x 3"

2" x 4"

B

1375158-1

1375158-2

Front Replacement Covers

1RU (1.75")

1479225-1

1479225-2

2RU (3.50")

1479222-1

1479222-2

Rear Replacement Covers

1RU (1.75")

1479224-1

2RU (3.50")

1479223-1

Description

Mounting Position

Panel Height

Front (W x D)

Rear (W x D)

Figure

Part Number

Single-Sided

Side Mount

35"

4" x 5"

A

1375165-1

78"

4" x 5"

1375258-1

Center Mount

35"

4" x 5"

B

1375167-1

78"

4" x 5"

1375260-1

Double-Sided

Side Mount

35"

4" x 5"

4" x 5"

A

1375164-1

78"

4" x 5"

4" x 5"

1375257-1

Center Mount

35"

4" x 5"

4" x 5"

B

1375166-1

78"

4" x 5"

4" x 5"

1375259-1

ORDERING INFORMATION

 Hinged Patch Panel Accessories

FEATURES

• 

For use with standard patch panels for hinged application where access
behind patch panel is limited

• 

Hinged feature allows patch panel to be folded down for easy access to the
back of the panel, while snapping securely into place for normal use

• 

Cable management panels have special ring spacing for hinged applications

• 

Hinged panels may not be stacked adjacent to one another in a rack without
a cable management panel with a 1/2" of empty space between them

Description

Rack Mount Units

Figure

Part Number

Patch Panel Hinge Kit

1RU (1.75”)

1479582-1

2RU (3.50”)

A

1479402-1

Cable Management Panel
for Hinged Patch Panels

1RU (1.75”)

1479732-1

2RU (3.50”)

B

1479733-1   

Closed

(Installed)

Open

Figure A

Figure B

 Figure A

Panel Height

Depth

Figure

Part Number

1RU (1.75")

6"

558266-1

2RU (3.5")

6"

A

558267-1

3RU (5.25")

6"

558268-1

4RU (7.00")

6"

558269-1

6RU (10.50")

6"

2111279-1

Hinged Wall Brackets for 19-Inch Panels

FEATURES

• 

Can be installed with hinges on either side for easier access

• 

Provided with cable tie laces to aid in dressing cables, have multiple threaded
holes allowing more than one panel to be mounted on a bracket, and rear
entry cable holes

ORDERING INFORMATION

Sc6_CableManagemet_v1.indd   23

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-24

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

6-24

ORDERING INFORMATION

Horizontal Ringed Cable Management Panels

FEATURES

• 

Panels mount to the front of 19-inch racks and provide for the orderly dressing
and routing of cable assemblies

• 

Threaded studs on the back of the panels allow the installation of an optional
Cable Support Bar (see this chapter)

• 

2U (3.50") 569049-1 comes with cable clips

Description

Height

Figure

Part Number

1RU Panel

1.75"

A

558329-1

2RU Panel

3.50"

B

558331-1

Figure A

Figure B

Description

Figure

Part Numbers

Top Trough

A

559370-1

Bottom/Middle Trough

B

559369-1

Rack Mount Cable Trough

FEATURES

• 

Light weight durable 11 AWG aluminum

• 

Fit standard 19-inch racks

• 

Top trough features:

Down-radiused cable exit to vertical cable management

Dimensions (overall): 4.20" H x 19.00" W x 3.75" D

Mounts in 1RU (1.75") of rack space

• 

Bottom/middle trough features:

Dimensions (overall): 5.22" H x 19.00" W x 3.75" D

Mounts in 3RU (5.25") of rack space

• 

Mounts to standard EIA hole pattern

• 

Provide cable management within the rack bay or multiple rack line-ups

ORDERING INFORMATION

Figure A

Figure B

Sc6_CableManagemet_v1.indd   24

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-25

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GEMENT

Description

Figure

Part Numbers

Top Trough

A

559370-1

Bottom/Middle Trough

B

559369-1

ORDERING INFORMATION

 Cable Support Bars

FEATURES

• 

Designed to provide additional cable support and routing control
in the rear of 19-inch racks and panels

• 

Cable support bars that mount directly to rack provide the best
support. Other bars are available for specialty application

Mounting

Figure

Compatible with Panel Part Number

Mounts to Back of Rack, 5" deep

A

557548-1

Mounts to Back of Rack, 2" deep

B

406042-1

Mounts to Back of Cable Management Panels

558329, 558331

558301-1

Mounts to Back of 110Connect and SL Series Patch Panels

1479860-1

Mounts to Back of 1RU XG and SL Series Multimedia Patch Panels

C

1933425-1

Figure C

Figure A

Figure B

ORDERING INFORMATION

Description

Part Number

Grounding Lug Kit

556438-1

Grounding Lug Kit

FEATURES

• 

Use for grounding panels to locations other than rack

• 

Accommodates a maximum wire size of 6 AWG

C-LOK, Solid and Stranded Copper Bonding Connectors

FEATURES

• 

Connects solid or stranded copper conductors in grounding applications

• 

Installs quickly and safely without special tools

• 

Meets requirements of: Telcordia TR-NWT-001075; UL Listed; Canadian
Standards Association

• 

Search C-LOK connectors at www.te.com/EnterpriseNetworks for additional
information and part numbers

Sc6_CableManagemet_v1.indd   25

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-26

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Mounting hardware is available for either wall or rack mount applications. 
Included is a full range of mounting system hardware and backboards, 
cable management hardware, mounting frames and support bars, as well as 
comprehensive fiber optic cable raceway systems for overhead and  
Plenum applications.

To better understand how the hardware can be utilized, the reference guide 
on this page gives appropriate use information. The icons shown within the 
reference chart represent the following equipment:

Termination Block Mounting Hardware

FEATURES

• 

Various options provide flexibility

• 

Fit standard 19", 23" and 35.5" equipment racks

• 

Mounting hardware and backboards available for either wall or rack mounting

• 

Wire management built-in, or available as accessory

Block/Patch Panel

Ultim8 Block

Feed-Thru (FT) Block

= Universal Mounting System (UMS)

 

= Type 105 Rod Mount Bracket

 

= Type 105 Back Mount Frame

Figure A

Figure C

ORDERING INFORMATION

MRJ21 Cable Support Bars

FEATURES

• 

Mounts to the back of 19-inch racks

• 

Designed to provide additional cable support and routing
control behind 19-inch racks and panels

• 

MRJ21 slotted manager bar for easy tie down

• 

Horizontal and vertical mounting option for MRJ21 tie down bar

Description

Depth

Figure

Part Number

MRJ21 Cable Manager Bar

6"

A

1933352-1

9"

B

1933352-2

12"

C

1933352-3

16"

D

1933352-4

Figure B

Figure D

Sc6_CableManagemet_v1.indd   26

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-27

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

ORDERING INFORMATION

The Universal Mounting System (UMS) accepts Ultim8, HighBand 10, 10-pair Series 
2, and 25-pair FT (Feed-Thru) blocks and UMS/Mini patch panels. It is a rugged, low 
cost, versatile alternative to traditional mounting systems. Besides providing a sturdy, 
easy-to-install interlinking foundation, the UMS features built-in wire and cable 
management, and convenient add-ons.

The mounting brackets interlink left-to-right and top-to-bottom to provide a 
foundation that is easy to install and easy to expand. The brackets are suitable for 
both rack and wall mount installations.

For fast installation, use the push rivets provided with the UMS backboard to attach 
the UMS brackets to the backboards.

Universal Mounting System (UMS)

The UMS easily expands from the  

Type 105 position to the Type 160 position

UMS In Type 105 position

UMS In Type 160 position

Description

Dimensions (HxWxD)

Part Number

UMS Basic Kit

 

Includes one pair of adjustable universal 
mounting brackets (holds up to 13 
Ultim8 blocks and/or label holders), two 
horizontal wire managers, and appropriate 
screws and rivets. Typical installation holds 
96 pairs using (12) 8-pair Ultim8 blocks 
(24-ports) and (1) Type 105 label holder. 
Kit mounts directly to a wall, or to an 
optional rack or wall mount backboard.  
Quantity: 1

14.75" x 8.25" x 5.25" 

(374.7 mm x 209.6 mm x 133.4 mm)

   UMS Basic Kit; Black

6657 2 165-40

   UMS Basic Kit; Gray

6657 2 165-00

Sc6_CableManagemet_v1.indd   27

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-28

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Vertical cable manager

Horizontal wire manager

19" equipment rack 
with three dual height 
backboards, each holding 
four Type 105 Universal 
Mounting Brackets and two 
vertical cable managers 
(1,152 pairs or 288 ports).

Connect here for 

Ultim8 blocks

Connect here for 25-pair 

FT blocks

Individual ribs on the vertical 
cable manager remove to 
provide additional room for 
routing patch cords or cables.

TECH TIP

When connecting two UMS brackets, use the 
inner slot for HighBand blocks or 10-pair Series 2 
blocks (Type 105) and the outer slot for 25-pair 
FT blocks (Type 160).

Universal Mounting System (UMS) Cable and Wire Managers

Description

Dimensions (HxWxD)

Part Number

UMS Vertical Cable Manager

Same footprint as the universal mounting bracket in the Type 105 position; provides 
additional cable management for larger installations or for patch cords. Unique 
restraining-finger design ensures cables remain in the channel, even with the cover 
removed. Interlinking tabs, left-to-right and top-to-bottom, match interlinking tabs on  
the universal mounting bracket.  Quantity: 1

11.88" x 8.25" x 5.25" 

(301.6 mm x 209.6 mm x 133.4 mm)

   UMS Vertical Cable Manager; Black

6657 2 005-44

   UMS Vertical Cable Manager; Gray

6657 2 005-04

Horizontal Wire Manager 

Includes individual horizontal wire manager and two nylon rivets to lock manager in 
position on UMS bracket. Attaches to top or bottom of UMS bracket. Two managers 
are included with each UMS basic kit; additional managers are spares or provide wire 
management along the bottom of an installation.  Quantity: 1

5.38" x 1" x 5" 

(136.5 mm x 25.4 m x 127.0 mm)

   Horizontal Wire Manager; Black

6657 2 005-43

   Horizontal Wire Manager; Gray

6657 2 005-03

ORDERING INFORMATION

Sc6_CableManagemet_v1.indd   28

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-29

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Description

Dimensions (HxWxD)

Part Number

UMS Vertical Cable Manager

Same footprint as the universal mounting bracket in the Type 105 position; provides 
additional cable management for larger installations or for patch cords. Unique 
restraining-finger design ensures cables remain in the channel, even with the cover 
removed. Interlinking tabs, left-to-right and top-to-bottom, match interlinking tabs on  
the universal mounting bracket.  Quantity: 1

11.88" x 8.25" x 5.25" 

(301.6 mm x 209.6 mm x 133.4 mm)

   UMS Vertical Cable Manager; Black

6657 2 005-44

   UMS Vertical Cable Manager; Gray

6657 2 005-04

Horizontal Wire Manager 

Includes individual horizontal wire manager and two nylon rivets to lock manager in 
position on UMS bracket. Attaches to top or bottom of UMS bracket. Two managers 
are included with each UMS basic kit; additional managers are spares or provide wire 
management along the bottom of an installation.  Quantity: 1

5.38" x 1" x 5" 

(136.5 mm x 25.4 m x 127.0 mm)

   Horizontal Wire Manager; Black

6657 2 005-43

   Horizontal Wire Manager; Gray

6657 2 005-03

UMS backboards provide a base for UMS brackets, and are available in standard 
equipment rack widths. Each width is available in single or dual height, holding one or 
two rows of mounting brackets, respectively. Backboards are black and match UMS 
brackets and cable managers.

Backboards will hold combinations of mounting brackets in both Type 105  
(Ultim8 and HighBand) and Type 160 (Feed-Thru) positions. Rotate backboards with 
mixed types 180

º

 to reverse the order of mounting. Silk-screening identifies which holes 

to use in different mounting configurations.

Wall mount backboards provide the same mounting base as the rack mount backboards 
but provide a deeper channel. They stand four inches (rather than 1.5") off the wall to 
allow for proper cable routing. Silk screening indicates correct installation of the UMS 
adjustable mounting brackets.

Universal Mounting System (UMS) Backboards

19" backboard, single height

19" backboard, dual height

19" configurations

23" configurations

ORDERING INFORMATION

 

Part Number

Description

Dimensions (HxWxD)

Rack Wall

Black

Grey

UMS backboard

Backboards ship 
one to a package

11.5" x 19" x 1.5"

6652 2 080-19

6652 2 069-19

23" x 19" x 1.5"

6652 2 081-19

6652 2 070-19

11.5" x 19" x 4"

6652 2 082-19

6652 2 067-19

23" x 19" x 4"

6652 2 083-19

6652 2 068-19

11.5" x 23" x 1.5"

6652 2 080-23

6652 2 069-23

23" x 23" x 1.5"

6652 2 081-23

6652 2 070-23

Sc6_CableManagemet_v1.indd   29

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-30

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

For larger installations, the high volume cable manager provides greater capacity and 
strength than horizontal wire managers that attach directly to UMS brackets.

Available in widths to match standard equipment racks, the high volume cable manager can 
be either rack or wall mounted. The manager includes a back mounting plate and a set of 
6" by 6" rings. The number and position of rings vary to allow use of the manager with a 
variety of UMS configurations. Mounting holes across the face of the mounting plate allow the 
position of rings to change to match the varying widths of UMS brackets in either Type 105 or 
Type 160 positions.

Designed as a companion to the universal mounting system, the high volume cable 
manager works in any application.

19" cable manager with 3 rings

35.5" cable manager with 6 rings

35.5" high volume cable 

manager with 5 rings,  

shown mounted above 5 Type 

105 mounting brackets

19" high volume cable 

manager with 4 rings,  

shown mounted above 3 Type 

105 mounting brackets

Universal Mounting System (UMS) High Volume Cable Managers

Description

Dimensions (HxWxD)

Part Number

19" cable manager, black only  Quantity: 1

6" x 19" x 6.5"  

(152.4 mm x 482.6 mm x 165.1 mm)

   3 rings

6657 2 005-19/03

   4 rings

6657 2 005-19/04

23" cable manager,

 black only  Quantity: 1

6" x 23" x 6.5"  

(152.4 mm x 584.2 mm x 165.1 mm)

   3 rings

6657 2 005-23/03

   4 rings

6657 2 005-23/04

35.5" cable manager, black only  Quantity: 1

6" x 35.5" x 6.5"  

(152.4 mm x 901.7 mm x 165.1 mm)

   4 rings

6657 2 005-35/04

   5 rings

6657 2 005-35/05

   6 rings

6657 2 005-35/06

6.5" cable manager, gray only; 2 rings  Quantity: 1

6.5" x 6.5" x 4.75"  

(165.1 mm x 165.1 mm x 120.65 mm)

6657 2 006-06/02

9" cable manager, gray only; 3 rings  Quantity: 1 

Designed to fit directly above 
UMS in Type 160 position

6.5" x 9.1" x 4.75"  

(165.1 mm x 231.14 mm x 120.65 mm)

6657 2 006-09/03

ORDERING INFORMATION

Sc6_CableManagemet_v1.indd   30

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-31

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Type 85 back mount frames accept 8-pair Series 2 blocks. The frames come with cable 
entry holes on the back and protective rubber grommets. Grommet holes are 1.5" 
(38.1 mm) in diameter. Back mount frames are made of stainless steel.

Type 85 Back Mount Frames

Type 85 back mount frame

Note: The depth dimensions listed 
are the actual depths of mounting 

brackets with no blocks installed.

Description

Dimensions (HxWxD)

Part Number

Type 85 back mount frames  Quantity: 1

   6 block positions, 1 hole

5.25" x 3.31" x 2.75"  

(133.3 mm x 84.1 mm x 69.9 mm)

6654 2 350-06/1

   11 block positions, 1 hole

9.63" x 3.31" x 2.75"  

(244.5 mm x 84.1 mm x 69.9 mm)

6654 2 350-11/1

   21 block positions, 2 holes

18.38" x 3.31" x 2.75"  

(466.7 mm x 84.1 mm x 69.9 mm)

6654 2 350-21/2

ORDERING INFORMATION

Type 105 back mount frames accept Ultim8, HighBand 10 and 10-pair Series 2 blocks and 
Type 105 UMS/Mini patch panels. The frames come with cable entry holes on the back and 
protective rubber grommets. Grommet holes are 1.5" (38.1 mm) in diameter. Back mount 
frames are made of stainless steel.

Type 105 Back Mount Frames

Type 105 back mount frame 

Note: The depth dimensions listed 
are the actual depths of mounting 

brackets with no blocks installed.

Description

Dimensions (HxWxD)

Part Number

Type 105 back mount frames  Quantity: 1

   6 block positions, 1 hole

5.25" x 4.06" x 2.75"  

(133.3 mm x 103.2 mm x 69.9 mm)

6655 2 450-06/1

   11 block positions, 1 hole

9.63" x 4.06" x 2.75"  

(244.5 mm x 103.2 mm x 69.9 mm)

6655 2 450-11/1

   21 block positions, 2 holes

18.38" x 4.06" x 2.75"  

(466.7 mm x 103.2 mm x 69.9 mm)

6655 2 450-21/2

   31 block positions, 3 holes

27.13" x 4.06" x 2.75"  

(689.0 mm x 103.2 mm x 69.9 mm)

6655 2 450-31/3

ORDERING INFORMATION

Sc6_CableManagemet_v1.indd   31

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-32

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

These back mount frames have a standard 2.0" (50 mm) channel depth and come with an 
attached ground lug.

Type 105 Back Mount Frames with Ground Lug

Back mount frame 

with ground lug 

(21-position shown)

Description

Dimensions (HxWxD)

Part Number

Type 105 back mount frames  Quantity: 1

   6 block positions, 1 hole

5.25" x 4.06" x 2.75"  

(133.3 mm x 103.2 mm x 69.9 mm)

6655 2 400-03

   21 block positions, 1 hole

18.38" x 4.06" x 2.75"  

(466.7 mm x 103.2 mm x 69.9 mm)

6655 2 400-00

ORDERING INFORMATION

Type 85 rod mount brackets accept 8-pair Series 2 rod mount blocks. Install rod mount 
brackets using support bars, or directly to a plywood backboard. 

Type 85 Rod Mount Brackets 

Type 85 rod mount bracket

Description

Dimensions (HxWxD)

Part Number

Type 85 rod mount brackets  Quantity: 1

   6 block positions

5.5" x 4.19" x 2" 

(139.7 mm x 106.4 mm x 50.8 mm)

6652 2 039-06

   11 block positions

9.88" x 4.19" x 2" 

(250.8 mm x 106.4 mm x 50.8 mm)

6652 2 039-11

   21 block positions

18.63" x 4.19" x 2" 

(473.1 mm x 106.4 mm x 50.8 mm)

6652 2 039-21

ORDERING INFORMATION

Sc6_CableManagemet_v1.indd   32

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-33

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Type 105 rod mount brackets accept Ultim8, HighBand 10 and 10-pair Series 2 
rod mount blocks and 105 mm UMS/Mini Patch Panels. Install rod mount brackets 
using support bars, or directly to a plywood backboard. 

Type 105 Rod Mount Brackets 

Rod mount bracket spacers are optional pieces that snap over the 0.47" (12 mm) 
rods to maintain uniform distances between rod mount blocks. 

Rod Mount Bracket Spacer 

Type 105 rod mount bracket

Description

Part Number

Rod mount bracket spacer  Quantity: 1

   0.1" (2.5 mm)

6619 2 046-00

   0.2" (5.0 mm)

6619 2 046-01

ORDERING INFORMATION

Description

Dimensions (HxWxD)

Part Number

Type 105 rod mount brackets  Quantity: 1

   6 block positions

5.5" x 4.19" x 2"  

(139.7 mm x 106.4 mm x 50.8 mm)

6652 2 040-06

   11 block positions

9.88" x 4.19" x 2"  

(250.8 mm x 106.4 mm x 50.8 mm)

6652 2 040-11

   21 block positions

18.63" x 4.19" x 2"  

(473.1 mm x 106.4 mm x 50.8 mm)

6652 2 040-21

ORDERING INFORMATION

Sc6_CableManagemet_v1.indd   33

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

Cable Management

Cable Management Accessories

6-34

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

CABLE MANA

GE

M

ENT

Wall or Rack Mount Mounting Frames

19" wide mounting frame

23" wide mounting frame

35.5" wide mounting frame

Description

Dimensions (HxWxD)

Part Number

19" mounting frame, 3-position  Quantity: 1

Supports up to (3) 21-position Type 85 or Type 105 mounting brackets; 
can be wall or rack mounted (EIA standard 19" equipment rack; 3 
mounting frames fit vertically in 7' rack) with 4 mounting screws 
(included). Fixed jumper routing rings included

25" x 19.38" x 4.25" 

(635 mm x 492.1 mm x 108 mm)

6652 2 100-00 

23" mounting frame, 3-position  Quantity: 1

Supports up to (3) 21-position Type 85 or Type 105 mounting brackets; 
can be wall or rack mounted (23" equipment rack) with 4 mounting 
screws (included). Fixed jumper routing rings included

25" x 24" x 4.25" 

(635 mm x 609.6 mm x 108 mm)

6652 2 114-00 

23" mounting frame, 4-position  Quantity: 1

Supports up to (4) 21-position Type 85 or Type 105 mounting brackets; 
can be wall or rack mounted (23" equipment rack) with 4 mounting 
screws (included). Fixed jumper routing rings included

25" x 24" x 4.25" 

(635 mm x 609.6 mm x 108 mm)

6652 2 113-00 

35.5" mounting frame, 5-position  Quantity: 1

Supports up to (5) 21-position Type 85 or Type 105 mounting brackets; 
can be wall or rack mounted (23" equipment rack) with 4 mounting 
screws (included). Fixed jumper routing rings included

26.5" x 35.5" x 4.25" 

(673.1 mm x 901.7 mm x 108 mm)

6652 2 101-00

ORDERING INFORMATION

Sc6_CableManagemet_v1.indd   34

12/7/12   3:53 PM

Tyco-catalog-AMP-2013-html.html
background image

7-1

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

Distributed Antenna Systems ..............................................................................7-3

Broadcast Products ...................................................................................................7-3

Undercarpet Cabling .................................................................................................7-3

Pre-Manufactured, Modular Power System ..................................................7-3

Residential Products .................................................................................................7-3

Sometimes you need more than cabling. TE offers a number 
of complementary products to our core foundation of copper 
and fiber cabling infrastructure management solutions. From 
AMPINNERGY’s modular power distribution system, to Undercarpet 
cabling options to Wireless, Broadcast or home network systems, 
TE Connectivity can provide you with a custom solution and the 
accessories you need for your specific application. 

Supplementary Solutions

Sc7_SupplementrySolutions_v1.indd   1

12/7/12   4:54 PM

Tyco-catalog-AMP-2013-html.html
background image

7-3

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

SUPPLEMENT

AR

Y SOL

UTIONS

Distributed Antenna Systems

As a leader in distributed antenna systems (DAS) for in-building and microcellular 
networks, TE's wireless solutions transform the way mobile service delivery networks are 
created, deployed and used for new mobile applications. 

For more information, visit www.te.com/ENWireless

Broadcast Products 

Bandwidth is in high demand and only TE products can meet the challenges of today’s 
always on, instant communications environment. From fiber connectivity to audio and 
video products to modular systems and connectors, TE’s Broadcast product line can help 
ensure reliability, scalability and flexibility of your network. 

For more information, visit www.te.com/broadcast

Undercarpet Cabling 

TE’s flexible, low-profile Undercarpet cabling system is ideal for any office, retail or 
gaming environment. Provide power, voice and data services to your equipment easily – 
all hidden from view. It is ideal for cabling open areas, such as lobbies, conference rooms, 
and retail displays, without using unsightly power poles or trenching. As your furniture, 
retail displays or kiosk configuration changes our Undercarpet products can be changed 
too allowing for maximum control and reduced downtime. 

To learn more, visit www.te.com/power

Pre-Manufactured, Modular Power System 

This UL/CSA-listed, AMPINNERGY brand modular power distribution system can be 
used to deliver power to workstations in raised floor installations, in modular offices 
furniture panels, retail display fixtures, gaming fixtures and more. All AMPINNERGY 
system components are factory tested and plug-and-play compatible allowing for easy 
reconfiguration and load balancing. AMPINNERGY is available in 5-wire shared neutral, 
and 8-wire shared or dedicated neutral systems. 

To learn more, visit www.te.com/power

Residential Products

Imagine whole-house data, voice, video and audio streamlined into one solution. 
TE’s AMP NETCONNECT Home Net-Works Residential Cabling System can perfect your 
multi-media signals with greater bandwidth and security. Bring office-like quality to your 
high-tech home with our next generation residential offerings. 

For more information, visit www.te.com/residential

Sc7_SupplementrySolutions_v1.indd   3

12/7/12   4:54 PM

Tyco-catalog-AMP-2013-html.html
background image

8-1

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TE products and solutions adhere to the latest industry standards 
including TIA, UL and more. This section is for your reference and to 
help you with specific installation issues like: designing an optimized 
data center, supporting industry standards, selecting the right 
cabling infrastructure and more.

Technical Reference

AirES cable improves attenuation due to lower dielectric

loss — resulting in smaller gauge copper than other cable.

The choice of conductor insulation is

critical to cable performance.

Sc8_TechReference_v1.indd   1

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-3

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFERENCE

  

Copper Design Technology

UPTIME PERFORMANCE STARTS AT CABLE CONNECTIONS

With Angled Insulation Displacement Contact (IDC) Technology, connections
will never be the source of system weakness. Cable connections and
terminations within data centers are subject to vibrations and mechanical
stresses not seen elsewhere within the enterprise. Seventy percent of network
downtime is attributed to the physical layer, or cables and connectivity
equipment. Angled IDC Technology produces the highest performing, most
reliable IDC in the industry. Angled IDC technology is used throughout
TE AMPCONNECT BRAND jacks, panels and termination blocks.

Angled IDC contacts are the most secure available, anywhere.

1. Insulation clamping ribs hold the wire securely—isolating the contact area

from vibration and mechanical stress.

2. Angled IDC’s make contact at 45

o

 angles across the wire’s axis make a

solid, gas-tight connection.

3. Axial and torsional restoring forces make a solid, gas-tight connection.

Billions of Connections

Angled IDC technology has been used in billions of connections worldwide,
and continues to set the pace for others to follow.

FEATURES

• 

Accepts 26-22 AWG insulated conductors

• 

Accepts solid or stranded insulated conductors

• 

Can be re-terminated 200 or more times

Angled IDC Technology

leaves more wire between contact points; provides a 

more reliable stress resistant connection.

Typical primary wire after being punched into a 110 IDC

positioning contacts at a 90

o

 angle results in a weak 

connection, which is prone to breakage.

Paired Terminal Technology

DESIGNED FOR PERFORMANCE

Angled IDC Technology produces Paired Terminal Technology. Angled
contacts allow for closer placement for contacts within a pair, and
separation between pairs of contacts—providing better coupling
performance and increase NEXT performance.

3

3

1

2

The LSA-PLUS Contact Diff erences:

1. Insulation clamping ribs hold the wire securely 

– isolating the contact area from vibration and 

mechanical stress.

2. Silver-plated contact tags at 45° angles across 

the wire’s axis make a solid, gas-tight connection.

3. Axial and torsional restoring forces make a 

solid, gas-tight connection.

Sc8_TechReference_v1.indd   3

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-4

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFERENCE

  

Cycle Life

UPTIME PERFORMANCE CONTINUES WITH LONG CYCLE LIFE

TE Connectivity Jacks are designed to go the distance

• 

SL Series jacks are tested to IEC 60512-9 durability with a 6 position plug in an 8 position jack

Contact constructed of high-strength Beryllium Copper for maximum elasticity

Terminal will not take a set after using a 6 position plug

• 

IDC design

Maximizes stored elastic energy and reduces permanent set

Exceeds ANSI/TIA 568 durability requirements of 200 terminations

     

• Capable of over 5000 terminations

SL Series Tool 

Better Terminations – Less Time – More Reliable

• 

Easier terminations

Simple lacing process

Less hand fatigue vs. punch down tool

• 

Faster terminations

Simplifi ed process allows terminations in half the time

• 

More consistent terminations

Pair twist controlled for every termination

Same termination across various technicians

• 

Optimal reliability solution

Step 4

Step 5

Step 6

Step 1

Step 3

Step 2

SL Series Modular Jack Termination 

Tool UTP Termination Method

Sc8_TechReference_v1.indd   4

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-5

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFERENCE

  

How AirES Cable Technology Lowers Temperatures While 
Increasing Uptime

Deployed in the Data Center:

• 

32% smaller than conventional category 6 cable

 

Improved electrical and physical properties

 

Increased reliability of electronics lowers Zero Bit-Errors

 

Increased reliability by improving airfl ow and thermal fl uctuations

 

Increased reliability by providing better circuit access

• 

Increased uptime

 

Improved electrical and physical properties

 

Increased reliability of electronics lowers Zero Bit-Errors

 

Increased reliability by improving airfl ow and thermal fl uctuations

 

Increased reliability by providing better circuit access

• 

Improved scalability

 

Better utilization of fl oor space

 

Decreased cable size

 

Fewer and smaller pathways

• 

The choice of conductor insulation is critical to cable performance

 

In AirES technology, air channels are used in the traditional FEP

 

Insulation, which results in a 17% better dielectric constant over conventional 
FEP cables

 

The result: Improved data communications in a smaller diameter cable.

 

32% smaller than typical Augmented category 6 Cable

• 

Hard to crush an AirES cable

 

Air channels within the FEP insulation are distributed evenly along the 
entire conductor, forming a unifi ed system of arched channels to strengthen 
the construction

AirES cable improves attenuation due to 

lower dielectric loss — resulting in smaller 

gauge copper than other cable.

The choice of conductor insulation is

critical to cable performance.

Competitor’s

Augmented Category 6

TE’s Plenum

Category 6A with AirES

Sc8_TechReference_v1.indd   5

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-6

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

TE’S POSITION ON STANDARDS

TE is a strong proponent of standards-based design for structured cabling systems. A strictly defined set
of standards helps ensure uniform application of physical layer networking products and creates a usable
infrastructure for communications networks.

However, TE also believes that by nature, the standards evolve into a lowest-common denominator
indicator of performance. In order to accommodate various competing interests, a significant amount of
“flexibility” gets built into the allowable tolerances. The cumulative effect of these tolerances can result
in structured cabling channels in which different components can have radically different electrical
performance characteristics.

Consequently, when various standards-compliant components from randomly selected vendors are used, the
net result could be conformance to the standards, but not efficient performance.

The research undertaken by TE for the TE Connectivity structured cabling system revealed that only an
impedance-matched structured cabling channel that conforms to a tightly defined subset of the performance
standards is capable of flawless data transmission.

TE, as a full system supplier, is able to deliver a complete system of impedance-matched components so
there is no guesswork. Choosing standards-compliant components randomly from unrelated vendors will
yield a standards-compliant channel, but may not result in optimum network performance.

Therefore, use the standards as a design guide, then make sure that you purchase standards-compliant
matched components.

THE BENEFITS OF STANDARDS

Imagine trying to link railroads together that are based on different gauges, to build anything with a 
combination of metric and American parts, to type a letter on something other than a QWERTY keyboard, 
or to wire a building for voice, data and video if all the components had different requirements. The key to 
simplifying all of these tasks is standardization. Bringing standards to the wiring and cabling segments of the 
building industry has enabled the industry to define a common infrastructure that allows many companies to 
provide common components. Strict adherence to these standards benefits everyone.

Telecommunications

Rooms

Horizontal 

Cabling

Work Area

Entrance Facilities and 

Equipment Rooms

Backbone Cabling 

Interbuilding

Backbone Cabling

Intrabuilding

The ANSI/TIA-568-C Series standard defines a typical, generic telecommunications cabling system.

Intermediate

Cross-Connects 

Telecommunications 

Rooms 

Main Cross-Connect

Sc8_TechReference_v1.indd   6

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-7

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

ENTRANCE FACILITIES

The entrance facility provides a connection point between the outside plant facilities—whether it is public 
network services, private network customer premises or a combination of both—and the interior premises 
cabling. Products used in this area include cables, connecting hardware, special protection devices and 
other connecting hardware.

The demarcation point separating the service provider’s cabling and the customer’s cabling may be part 
of the entrance facilities. Because the location of the demarcation point is determined by state and federal 
regulations, the local regulated carrier (telephone service provider) or competitive access provider should 
be contacted for detailed information.

The primary standards for this area are outlined in ANSI/TIA-569-B, Commercial Building Standard for 
Telecommunications Pathways and Spaces, and J-STD-607-A, Commercial Building  
Grounding/Bonding Requirements.

TE manufactures special overvoltage blocks, protection devices and building entrance terminals for both 
fiber and copper cabling for use in this area.

EQUIPMENT ROOMS

The ANSI/TIA-568-C Series standard makes a distinction between equipment rooms and 
telecommunications rooms because of the nature of complexity of the equipment they contain. However, 
an equipment room may alternately provide any or all of the functions of a telecommunications room. 

Equipment rooms provide a controlled environment to house telecommunications equipment. This 
equipment may include connecting hardware, splice closures, grounding and bonding facilities and 
protection devices, where applicable. Switches, routers and other active equipment may reside in the same 
rack or cabinet space as the passive cabling infrastructure.

In the premises cabling backbone hierarchy, an equipment room may contain either the main crossconnect 
or the intermediate cross-connect. The equipment room may also contain network trunk terminations and 
auxiliary terminations that are under the control of the premises cabling administrator.

The primary standards for this area are outlined in 

ANSI

/TIA-569-B, Commercial Building Standard for 

Telecommunications Pathways and Spaces.

TE manufactures a wide variety of fiber and copper patch panels, termination blocks and cable 
management solutions that are well suited for this area.

Sc8_TechReference_v1.indd   7

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-8

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

TELECOMMUNICATIONS ROOMS

Telecommunications rooms may provide various functions for the cabling system and because of this they 
are treated as a distinct subset in the cabling system hierarchy.

The primary function of a telecommunications room is to provide a termination point for horizontal cable 
distribution, that supports all voice, data, video and other applications requiring structured cabling. The 
telecommunications room also serves as a termination point for backbone cable. The cross-connection of 
these two parts of the premises cabling is an important function of the telecommunications room. 
Cross-connections may be accomplished using jumper wires or patch cords, and TE products handle both 
methods equally well.

Telecommunications rooms may also house cross-connects for different portions of the backbone cabling 
system. These cross-connects are sometimes used to tie different rooms together in a ring, bus or 
tree configuration.

Telecommunications rooms also provide a controlled environment for specific areas of a building. These 
rooms may house telecommunications equipment, connecting hardware and splice closures as well as devices 
such as routers and hubs. In some instances, the demarcation point and protection devices may be located in 
a telecommunications room.

The 

ANSI

/TIA-568-C Series standard details cable routing and installation practices for 

telecommunications rooms to prevent cable stress and to properly organize and manage cables.

Additional standards for this area are outlined in 

ANSI

/TIA-569-B, Commercial Building Standard for 

Telecommunications Pathways and Spaces.

TE manufactures a wide variety of blocks and patch panels capable of providing termination and cable 
management for a wide range of wire sizes and cable types found in telecommunications rooms.

FOR MORE INFORMATION

Although this catalog presents a brief overview of information contained in the standard, persons involved 
with the installation and maintenance of structured cabling systems should obtain a copy of the complete 
standard and/or related standards.

Technical standards that address various aspects of commercial cabling include:

• 

ANSI

/TIA-568-C, Series, Commercial Building Telecommunications Cabling Standard

• 

ANSI

/TIA-569-B, Commercial Building Standard for Telecommunications Pathways and Spaces

• 

ANSI

/TIA-570-B, Residential Telecommunications Cabling Standard

• 

ANSI

/TIA-606-B, Administration Standard for the Telecommunications Infrastructure of 

Commercial Buildings

• 

J-STD-607-B, Commercial Building Grounding/Bonding Requirements

Sc8_TechReference_v1.indd   8

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-9

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

For information on obtaining copies of any of these standards, please contact:

Global Engineering Documents
800.854.7179 or 303.397.7956
www.global.ihs.com

ISO 11801 (International Standard) www.iso.ch

NEC (National Electrical Code), written and distributed by the National Fire Protection Association (NFPA) 
www.NFPA.org

FUSE

ON

OFF

FUSE

ON

OFF

Work Area

Work Area 

Cable

Telcom 

Outlet

Station 

Field

Equipment 

Field

Patch Cord

Data Hub

3 m

90 m (Max)

A + B < 100 m 

Equipment Cable

Station 

Cable

Transition 

Point 

(Optional)

7 m

A

B

Work Area

Work Area 

Cable

Telcom 

Outlet

Station 

Field

Equipment 

Field

Patch Cord

Data Hub

5 m (Max)

90 m (Max)

A + B + E < 100 m

Equipment Cable

Station 

Cable

Transition 

Point 

(Optional)

A

B

E

ISO/IEC 11801 Horizontal Channel/Link Model

ANSI/TIA-568-C Series Horizontal Channel/Link Model

Sc8_TechReference_v1.indd   9

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-10

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

The 

ANSI

/TIA-568-C.0 Series standard addresses two basic wiring schemes for the telecommunications 

room: interconnection and cross-connection.

Both the backbone and the horizontal cabling are terminated on connecting hardware that meets  
the requirements of the 

ANSI

/TIA-568-C Series standard. However, the standard prohibits the use of these 

terminations for moves, adds and changes. Any connection between the backbone and horizontal 
cabling must be accomplished through the use of a “horizontal cross-connect” between the common 
equipment and the connecting hardware to which the horizontal cabling is terminated. This connection may 
be made using an interconnection or a cross-connection cabling scheme.

An interconnection is a cabling scheme that provides for a direct connection between connecting 
hardware, such as a patch panel, and active equipment.

A cross-connection is a cabling scheme between cabling runs, subsystems and equipment using  
patch cords or jumper wires that attach to connecting hardware on each end.

Common equipment that utilizes cables that extend an individual port may be permanently terminated or 
interconnected to the connecting hardware for the horizontal cabling. Direct interconnections such as this 
reduce the number of connections in a channel, but may also reduce the flexibility, especially as the volume 
of moves, adds and changes increases.

Interconnection

Cross-Connection

INTERCONNECTION VS. CROSS-CONNECTION

Sc8_TechReference_v1.indd   10

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-11

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

Backbone Cabling

Backbone cabling provides interconnections between the
telecommunications rooms, equipment rooms and entrance facilities.
Backbone cabling consists of cables, main and intermediate crossconnects,
mechanical terminations and patch cords or jumper wires. Backbone cabling
can be within buildings (intrabuilding) or between buildings (interbuilding).

The

ANSI

/TIA-568-C Series standard requires that backbone cabling

use a hierarchical star topology. Each horizontal cross-connect in a
telecommunications room is cabled to an intermediate cross-connect and
then to a main cross-connect (or directly to a main crossconnect), with
no more than two hierarchical levels of cross-connect in the backbone
cabling. These cross-connects may be located in telecommunications rooms,
equipment rooms or entrance facilities.

Recognized cables for use in backbone

cabling include the following:

100 Ohm UTP 

unshielded twisted pair

 cable  

four or more pairs

62.5/125 

µ

m, multimode optical fiber cable

50 

µ

m, multimode optical fiber cable

Singlemode optical fiber cable

Backbone cabling uses a hierarchical star topology.

Intermediate

Cross-Connects 

Telecommunications 

Rooms 

Main Cross-Connect

50

µ

m, laser optimized multimode fiber optic cable

300 m and 550 m

Sc8_TechReference_v1.indd   11

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-12

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

Horizontal Cabling

Horizontal cabling extends from the work area telecommunications outlet to
the horizontal cross-connect in the telecommunications room. Horizontal
cabling includes the cables, the telecommunications outlet in the work
area, the mechanical termination and patch cords or jumper wires and cable
management solutions located in the telecommunications room.

• 

Voice service

• 

Internet service

• 

Video and conferencing services

• 

Premises switches, routers and hubs

• 

Data communications to support fax, storage servers, network printers

• 

Local area networks (LANs)

• 

Life safety systems such as security, fire alarm and door entrance

• 

Automation systems such as lighting and HVAC control

• 

Other building signaling systems, such as CCTV, nurse call, paging,
audio and others

Intermediate

Cross-Connects 

Telecommunications 

Rooms 

Main Cross-Connect

Recognized cables for use in horizontal

cabling include the following:

100 Ohm UTP 

unshielded or shielded Cat 5e, Cat 6 or 

Cat 6A twisted pair

 cable 

four pairs

62.5/125 

µ

m, multimode optical fiber cable

50 

µ

m, multimode optical fiber cable

50

µ

m, laser optimized multimode fiber optic cable 

300 m and 550 m

Sc8_TechReference_v1.indd   12

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-13

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

Moving offices, changing floor plan layouts and relocating equipment and people 
is a common practice in an organization. Horizontal cabling is often one of the 
more dynamic areas of the premises system. However, after installation, horizontal 
cabling is often much less accessible than backbone cabling, and the time, effort 
and skills required to change or modify it can be extremely high. Horizontal 
cabling should be designed with the intention of minimizing ongoing maintenance 
and relocation so that moves, adds and changes can be accomplished from the 
telecommunications and equipment rooms. Additional consideration should be 
given to accommodating a wide range of applications in order to reduce the 
necessity of changes to the cabling as users’ needs evolve.

Care should be given to separate telecommunications cabling from electrical 
facilities that generate high levels of electromagnetic interference (EMI). 
Fluorescent lights, copy machines, heating/cooling devices, motors and 
transformers that support the building’s mechanical requirements all contribute 
to EMI. ANSI/TIA-569-B specifies separation of horizontal cabling pathways from 
common sources of EMI.

Horizontal cabling is required to use a star topology. Each work area 
telecommunications outlet is to be connected to a horizontal cross-connect or 
interconnect in the telecommunications room. Each work area is to be served by 
a telecommunications room.

Pair 1 = White-Blue/Blue

Pair 2 = White-Orange/Orange

Pair 4 = White-Brown/Brown

Color Codes for Horizontal 100 Ohm UTP Cable 

or for Patch Cords

MAXIMUM DISTANCES

The maximum distance of a copper horizontal cabling run is 90 meters (approximately 295 feet) from 
the mechanical termination at the horizontal cross-connect in the telecommunications room to the 
telecommunications outlet in the work area.

Cross-connect jumper wires and patch cords used in the cross-connect facilities should not exceed 6 meters 
in length (approximately 20 feet).

Pair 3 = White-Green/Green

Sc8_TechReference_v1.indd   13

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-14

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

These and other types of adapters can have a detrimental effect on the transmission performance of the
telecommunications cabling system. It is important to consider the compatibility of these adapters to
premises cabling equipment before connecting them to the network.

A successful, high-performance premises wiring system requires more than simply purchasing the proper
standards-compliant cables and hardware. Care must be taken to ensure that the components are installed
properly according to industry-recognized practices.

Performance specifications called out in the ANSI/TIA-568-C Series standard are based on the assumption
that proper installation techniques and management practices have been followed. If recommended cabling
precautions and installation methods are not observed, specified transmission capabilities of cabling
components may not be achieved.

Installation should be performed by trained, certified installers such as the authorized TE Cabling System
Certifiers who are authorized to provide an TE product and performance warranty.

WORK AREA

The work area components of a premises cabling system are the most visible to office workers. Work
area components extend from the telecommunications outlet to the station equipment, such as traditional
telephones, VolP devices, networked computers, fax machines and shared devices such as network printers.
The length of cords used in the work area are assumed to be no longer than 3 meters (approximately 9.8 feet)
in establishing the maximum length for the horizontal cabling of 100 meters total, and the cords should meet or
exceed the requirements for patch cords outlined in the standard.

Common patch cords used in the work area have identical connectors on both ends, but cords may
vary widely in design depending on the application. Sometimes adapters are required to accommodate
specific equipment. If adapters are used, they should be external to the outlet and not a part of the
Permanent Link.

Types of adapters include:

• 

Special adapters to mate an equipment connector to the telecommunications outlet when they are
different styles (e.g. baluns)

• 

A “Y” adapter to branch two services off of a single cable

• 

Adapter which transpose pairs for compatibility

• 

Adapters for equipment that requires termination resistors

Intermediate

Cross-Connects 

Telecommunications 

Rooms 

Main Cross-Connect

Sc8_TechReference_v1.indd   14

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-15

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

Cable Installation

Do pull cables to minimize the distance

of the run and eliminate large loops.

Do bundle cables in a neat, orderly

fashion, and use hook-and-loop ties.

Do make sure that pair twists are

maintained within 1/2" (12 mm) or less 

of the termination point.

Do follow recommendations for cable

bend radius. In spaces with UTP terminations, 

cable bend radius should not be less than 

four-times the cable diameter for horizontal 
cable, and should not be less than ten times 

the cable diameter for multipair cable.

Don’t exceed 110 Newton's (25 lb/f) of

pulling forces when running cables.

Don’t cinch cable bundles too tightly,

or use plastic cable ties.

Don’t untwist pairs when terminating.

Don’t ever bend or kink cable too sharply.

Cable Diameter + d

Radius = 4 x d

DO

DON’T

Suggested Single 

Panel Cutout

Suggested Flush Mount Panel 

Application Cutout

Suggested Modular Jack Cutouts

Sc8_TechReference_v1.indd   15

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-16

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

Jack Pin-Outs

1 2 3 4 5 6 7 8 

T3 

T2 

T4 

R4 

R1  T1 

R3 

R2 

1 2 3 4 5 6 7 8 

T2 

T3 

T4 

R4 

R1  T1 

R2 

R3 

R 1

1 2 3 4 5 6 7 8

T 1

T 2

R 1

R 2

T568A RJ45

10Base-T

USOC RJ11

T568B RJ45

Token Ring

USOC RJ14

Position 1

Shorts to 

Position 4

Position 2

Shorts to 

Position 5

TP-PMD

USOC RJ25

USOC RJ61

USOC RJ48X

1 2 3 4 5 6 7 8 

T1 

T2 

R2 

R1 

1 2 3 4 5 6 7 8 

T2 

R1  T1 

R2 

1 2 3 4 5 6 

R1  T1 

1 2 3 4 5 6 

T2 

R1  T1 

R2 

1 2 3 4 5 6 

T2 

R3 

R1  T1 

T3 

R2 

1 2 3 4 5 6 7 8 

T4 

T2 

R3 

R4 

R1  T1 

T3 

R2 

Sc8_TechReference_v1.indd   16

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-17

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

25-Pair Cable Color-Coding

Pair Number

Cable Color

Color Coding

Tip & Ring

50-Pin Positions

66 or 110 Positions

1

White/Blue
Blue/White

Tip 1

Ring 1

26

1

1

2

2

White/Orange
Orange/White

Tip 2

Ring 2

27

3

3
4

3

White/Green
Green/White

Tip 3

Ring 3

28

3

5
6

4

White/Brown
Brown/White

Tip 4

Ring 4

29

4

7
8

5

White/Slate
Slate/White

Tip 5

Ring 5

30

5

9

10

6

Red/Blue
Blue/Red

Tip 6

Ring 6

31

6

11

12

7

Red/Orange
Orange/Red

Tip 7

Ring 7

32

7

13
14

8

Red/Green
Green/Red

Tip 8

Ring 8

33

8

15
16

9

Red/Brown
Brown/Red

Tip 9

Ring 9

34

9

17
18

10

Red/Slate
Slate/Red

Tip 10

Ring 10

35

10

19

20

11

Black/Blue
Blue/Black

Tip 11

Ring 11

36

11

21

22

12

Black/Orange
Orange/Black

Tip 12

Ring 12

37

12

23
24

13

Black/Green
Green/Black

Tip 13

Ring 13

38

13

25
26

14

Black/Brown
Brown/Black

Tip 14

Ring 14

39

14

27
28

15

Black/Slate
Slate/Black

Tip 15

Ring 15

40

15

29

30

16

Yellow/Blue
Blue/Yellow

Tip 16

Ring 16

41
16

31

32

17

Yellow/Orange
Orange/Yellow

Tip 17

Ring 17

42

17

33
34

18

Yellow/Green
Green/Yellow

Tip 18

Ring 18

43

18

35
36

19

Yellow/Brown
Brown/Yellow

Tip 19 

Ring 19

44

19

37
38

20

Yellow/Slate
Slate/Yellow

Tip 20

Ring 20

45
20

39

40

21

Violet/Blue
Blue/Violet

Tip 21 

Ring 21

46

21

41

42

22 

Violet/Orange
Orange/Violet

Tip 22

Ring 22

47
22

43
44

23

Violet/Green
Green/Violet

Tip 23

Ring 23 

48

23

45
46

24

Violet/Brown
Brown/Violet

Tip 24 

Ring 24

49
24

47

48

25

Violet/Slate
Slate/Violet

Tip 25 

Ring 25

50

25

49
50

Sc8_TechReference_v1.indd   17

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-18

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

The ANSI/TIA-569-B Series Commercial Building Telecommunications Wiring Standard defines 
pin/pair assignments for eight-position modular jacks in the work area. The preferred wiring 
configuration is T568A. A second, optional configuration, T568B, is allowed to accommodate 
certain eight-pin wiring systems already in use (specifically AT&T 258A or WECO wiring).

For modular RJ45 patch cords, 568A or 568B wiring are both usable, regardless of which 
wiring scheme is used in the horizontal cabling.

A crossover cord is wired T568A on one end and T568B on the other, and is typically used 
for peer to peer networking or to connect stacked hubs or switches. Many active devices now 
have a switch that crosses one port, negating the need for a crossover cable.

Wiring schemes also raise a variety of questions:

Q:

What’s the difference between T568A and T568B?

A.

The only difference is the positioning of the green and orange pairs of wires.

Q:

Is there a performance difference between T568A and T568B?

A:

No. Both wiring schemes have to meet the same performance criteria.

Q:

Why two schemes?

A:

The reason is outside of the scope of this discussion but it is related to old telephone 
legacy issues. All you really need to know is that there are two schemes, and how to 
deal with them.

The solution really is fairly simple: Just pick one wiring scheme and use it consistently 
throughout your network. The only problem you would ever encounter would be if the two 
wiring schemes were accidentally mixed in an installation. T568B is the predominate scheme 
in the United States; T568A is popular in Canada and in many other countries. The safest way 
to determine which to use is to check with the network equipment provider to determine the 
predominant wiring scheme used in the equipment. The reason for this check is quite simple: 
you can change the wiring scheme used in the network but you cannot change the wiring 
scheme used in the network equipment.

WIRING TO STANDARDS

TIA/EIA T568A

  

Standard

TIA/EIA T568B 

Standard

Pair  3 

Pair  1 

Pair  2 

RJ45 Jack Positions 

T568B 

Pair  4 

  

1   2   3   4   5   6   7   8 

   W- O  O   W- G  BL  W- BL  G  W- BR  BR 

Pair  2 

Pair  1 

Pair  3 

RJ45 Jack Positions 

T568 A 

  

1   2   3   4   5   6   7   8 

   W- G  G   W- O  BL  W- BL  O  W- BR  BR 

Pair  4 

TIA/EIA T568A

  

Standard

TIA/EIA T568B 

Standard

Pair  3 

Pair  1 

Pair  2 

RJ45 Jack Positions 

T568B 

Pair  4 

  

1   2   3   4   5   6   7   8 

   W- O  O   W- G  BL  W- BL  G  W- BR  BR 

Pair  2 

Pair  1 

Pair  3 

RJ45 Jack Positions 

T568 A 

  

1   2   3   4   5   6   7   8 

   W- G  G   W- O  BL  W- BL  O  W- BR  BR 

Pair  4 

Sc8_TechReference_v1.indd   18

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-19

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

HOW TO CHOOSE THE RIGHT CABLING INFRASTRUCTURE

A Brief History of Cabling

Over the past 40 plus years there have been unprecedented advances in networking technology. 
Since the early 1970s with the development of Ethernet, rates for point-to-point data transfer have 

increased by a factor of ten thousand. From one Mb/s StarLan to 10 Gb/s Ethernet, the steady increase 
in bandwidth has been fueled by an ever increasing demand for more; more speed, more applications, 
more memory and more devices.

Demand for faster speed comes from continual increases in processor capability and advanced 

operating systems that enable development of new applications. These applications and their associated 
devices create more network usage and congestion, driving demand for more bandwidth. The need for 
this additional bandwidth is seen first at network bottlenecks. When a section of the network becomes 
a bottleneck, network equipment, such as Ethernet switches and servers, are replaced with the next 
generation of equipment with faster processors, more memory, improved operating systems and the 

inherent ability to run more complex applications.

Over time, network equipment speeds outpace the infrastructure that connects the devices; In the 
transition of 10Base-T to 100Base-TX, for example. Networks with category 3 cabling systems could 
support the first few generations of switches and computers that supported 10 Mb/s Ethernet over 100 
meters. With the introduction of the 100Base-TX protocol, bandwidth limitations between devices were 
removed. However, category 3 cabling was insufficient to support the 10x increase in data rate, which led 
to the development of category 5 cabling to support 100 Mb/s over 100 meters.

Ignoring category 4, which came and went quickly, network planners faced a decision on which cabling 
system to install. At that time, the majority of networks operated with 10Base-T network devices. Yet 

category 3 cabling would not support the emerging 100Base-TX protocol. The good news, however, was 

that category 5 would run 100Base-TX and was backward compatible with category 3. In other words, 
any application designed for category 3 (10Base-T) would run just as well, if not better, on category 5 

cabling systems. The logical choice was to install category 5 in anticipation of applications requiring 
100Base-TX.

Sc8_TechReference_v1.indd   19

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-20

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

Selecting the Infrastructure: Follow the Lead of IEEE

The same scenario faces network planners today as cabling systems are designed to withstand multiple 

replacements of active equipment. Most active network equipment—including computers, servers, Ethernet 
switches, routers and hubs—have a maximum useful life of three to five years before they become obsolete. In 

contrast, structured cabling historically has a useful life of 10 to 15 years. Therefore, the structured cabling you 

install today must outlive at least three generations of networking equipment upgrades. 

The challenge is how to determine what types of active equipment will exist in three product generations; the 

answer can be found with IEEE. This organization consists of networking, equipment manufacturers such as 
Cisco, Nortel, Juniper and others that look at the future of networking, and develop solutions for future product 
generations. Using IEEE standards as a guide, it is possible to see the direction for both active equipment and 
cabling requirements for the next few generations.

IEEE has already released standards for 10 GbE over optical fiber, over short range copper (CX4), and twisted 
pair copper.

With the advent of these new standards it is clear that the IEEE has set a direction that 10 GbE over UTP 

is going to be a reality in upcoming generations of network equipment and this is fully supported by the 

standards making bodies, TIA and ISO.

Focus on the Critical Decision Criteria

The questions remain: with all the fiber and copper cabling choices at your disposal, which do you install 

today? There is no simple answer, because each network is unique. Beware of one-size-fits-all solutions as they 

cannot possibly account for the infinite numbers of variables you must consider when selecting your cabling 

infrastructure. 

As you make your cabling infrastructure decisions, keep in mind your bandwidth requirements and the 

timing of your implementation. The following are just three possible scenarios based upon very different 
network requirements:

Scenario 1:

 You need 10 GbE right now. If this is the case, choose Augmented category 6 cable or 10 GbE 

over fiber. Fiber can be more expensive than copper, due to media conversion and more expensive ports 
on equipment, but 10 GbE fiber ports are readily available today from most major switch manufacturers. 
10GBASE-T products for Augmented category 6 products are in their infancy, as of this publication, but will 

become more main stream in the coming years.

Scenario 2:

 You are occupying the space for the short-term only. Your plan is to move in the next two to 

three years. In this case, the logical choice is a Category 6 cabling solution. You will not be in the building 
long and category 6 will support 10 GbE at the shorter distance of 37 meters, just in case you do require 10 
GbE in the near term. Why is category 5e not a good choice in this scenario? Back in 2005, the dominant 
UTP cabling standard for new installations shifted from category 5e to category 6. In addition, category 5e 
is not recognized by IEEE or TIA to support 10GBASE-T because category 5e cannot support 10 GbE for 
any practical distance.

IEEE STANDARDS ACTIVITY

IEEE 802.3z

Gigabit Ethernet over Fiber

Released 1998

IEEE 802.3ab

1000Base-T (Gigabit Ethernet over UTP)

Released 1999

IEEE 802.3ae

10 GbE over Fiber

Released 2002

IEEE 802.3ak

10 GbE over short range Copper (CX4)

Released 2003

IEEE 802.3an

10Gbase-T (10GbE over Copper)

Released 2006

Sc8_TechReference_v1.indd   20

12/14/12   12:02 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-21

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

Building For Bandwidth in the Future

Technology advancements in networking will continue. New processor technology, coupled with new operating systems, will 
allow the creation of advanced applications and services. These new applications will demand more and more bandwidth, 
driving the need for higher speed protocols and cabling to support these protocols. Your situation may dictate a fiber or a 
category 6 solution. Yet if you own your space, or have a long term lease, a good rule of thumb is to design your passive 
cabling infrastructure to endure at least three generations of active networking gear with an Augmented category 6 solution. 
To design for three generations, look to the IEEE and educate yourself on the applications being developed for the future. This 
offers an invaluable guide toward building for bandwidth in the future.

TE Infrastructure Solutions

TE manufactures and distributes a complete portfolio of standards-based, technologically superior solutions that support 
voice, data, security, audio, video, controls and other building and campus systems. The TE Connectivity Structured Cabling 
Solution provides a complete copper and fiber cable, connectivity and cable management solution from the entrance facility 
to the desktop and across the campus. Supported by an exceptional warranty, TrueNet is the choice of network managers 
worldwide who operate high-value and mission-critical networks. 

The chart below shows just a few of the TE cable solutions used to support common enterprise applications. Integral to each 
solution are the TrueNet patch panels, fiber frames, connectors, cable management, termination/splice/storage panels and 
other products for every unique requirement in the passive portion of your network.

IEEE Standard Designation

Data Rate

Distance Limitation

Common Applications

TE Connectivity Solutions

802.3ab

1000Base-T

1000 Mb/s

100 Meters

Desktop Computing

Category 5e, 6 and 6A

802.3z

1000Base-SX

1000 Mb/s

550 Meters

Enterprise backbone

Laser Optimized Multimode Fiber

1000Base-LX

1000 Mb/s

5 Kilometers

WAN, MAN

Singlemode Fiber

802.3an

10GBase-T

10 Gb/s

100 Meters (Cat)

Data Center, R&D Computing, 
High Resolution Video, 
Advanced Desktop Computing

Category 6A 
 
Category 6

55 Meters (Cat 6)

802.3ae

10GBase-SR/SW

10 Gb/s

300 Meters

Data Center and Enterprise 
Backbone Cabling

Laser Opitimized Multimode Fiber

10GBase-LR/LW

10 Gb/s

10 Kilometers

WAN, MAN

Singlemode Fiber

10GBase-ER/EW

10 Gb/s

40 Kilometers

WAN

Singlemode Fiber

10GBase-LX-4

10 Gb/s

300 Meters

Data Center and Enterprise 
Backbone Cabling

Standard Grade Multimode Fiber

10GBase-LX-4

10 Gb/s

10 Kilometers

WAN, MAN

Singlemode Fiber

802.3af

Power over 
Ethernet

10/100/1000 
Mb/s

100 Meters

VoIP, WiFi, RFID, IP Security

Midspan PoE

802.3ba

40GBASE-KR4
40GBASE-CR4
100GBASE-CR10
40GBASE-SR4
100GBASE-SR10
40GBASE-LR4
100GBASE-LR4
100GBASE-ER4

40/100 GbE

100 or 150 Meters

Data Center

Laser Optimized Multimode 
and Singlemode Fiber

Scenario 3:

 Building space is on a long-term lease or the building is owned; bandwidth requirements are substantial. 

Choose Augmented category 6. History says your upfront investment will pay off in the long-term. Augmented category 6 
will be more expensive than category 6, however, the installation time and cost will be virtually the same. In this scenario, 

Augmented category 6 offers a cabling system that will be in service for at least three generations of active network gear. 

In the scope of any networking project, the infrastructure is a relatively small expense. Adding the small capital expense 
for Augmented category 6 cabling will defer or eliminate future costs of cabling system upgrades as new applications 
require replacement of active networking gear.

Sc8_TechReference_v1.indd   21

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-22

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

CHOOSING THE RIGHT ETHERNET PATCH PANELS

Category 5e, 6, or Augmented Category 6? 

IDC punchdown or modular? T568A or T568B? Shielded or unshielded?

Will I choose the right Ethernet patch panel for my application? 

Will this choice work with future applications? Am I getting the best overall value?

How do I ensure the integrity of my network? 

Can the infrastructure grow and change without service disruptions?

With all the choices you face as you design your network and select equipment, including available 
Ethernet patch panels, it’s easy to become confused and frustrated. Ultimately your choice of Ethernet 
panels should fit the applications you plan to run. TE has written this short tutorial to guide you through 
these decisions, to make them as painless as possible and offer you the best solution for your network.

First, let’s ask a few key questions. Your answers will help guide you in the decision process. Next, we will 
briefly discuss each of the most popular options available so you can draw conclusions based on your 
network needs.

DISCOVERY QUESTIONS

• 

What applications are you or do you plan to run in this facility? Take into 
account not only what you are doing today, but what you probably will 
be doing tomorrow i.e. 10/100Base-T? 1000Base-T? 10GBase-T?

• 

What type of LAN network are you designing? Data center? Data backbone? Workstation?

• 

Is the project a new network installation or an addition to an existing network?

• 

Is the installation being built to expand existing capacity with current data capabilities or is it for 
new, faster data applications?

Answers to these questions will guide you to a particular cable type, a particular data patch panel, and 
the means to terminate the cable into the patch panel—whether the terminations into the patch panel 
involve “punchdown” cable terminations, pre-made telco-type multi-pair cable ends, or standard RJ45 
cable ends.

The general guidelines for network transmission capabilities segment the data network; data center and 
data network backbone system applications require the highest level of transmission capabilities, while 
feeds to work areas generally require a bit less. However, all network connectivity should be designed 
with only the highest network engineering standards available.

Sc8_TechReference_v1.indd   22

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-23

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

Category 5e, 6 and 6A Cabling

The Telecommunications Industry Association (TIA) standards group consists of a variety of industry 
experts including connectivity and cable manufacturers, distributors, installers, and end customers. 
The TIA determines certain transmission characteristics that must be met to qualify a cable for certain 
network applications.

Category 5e

 is currently the minimum TIA recommended category of wiring for new installations. 

Electrical characteristics for NEXT, FEXT, ELFEXT, PSNEXT, PSELFEXT, delay skew, propagation 
delay, attenuation, and return loss are specified to 100 MHz. category 5e was developed with 
the specific intent of supporting Gigabit Ethernet. Because all TIA standards require backwards 
compatibility, category 5e will also support all lower-rated categories and protocols such as 
10/100 Base-T.

Category 6

 is gaining popularity for new installations. Electrical characteristics for NEXT, FEXT, 

ELFEXT, PSNEXT, PSELFEXT, delay skew, propagation delay, attenuation, and return loss are 
specified to 250 MHz. Improvements in all electrical parameters are part of the higher TIA category 6 
standard. category 6, while providing a “bigger pipe” for improved throughput, also has a maximum 
100 meters of support for Gigabit Ethernet transmission.

Augmented Category 6

 is the cutting edge of UTP cabling. It is similar to cat 6, but is characterized 

to 500 MHz and is also capable of running 10GBASE-T. Testing parameters are similar to that of 
cat 5e and cat 6, with the added benefit of compliance to Alien (Bundled) Crosstalk requirements: 
ANEXT, AACRF, PSANEXT and PSAACRF.

Category 7

 is a proposed standard for a fully shielded, 4-pair cabling system with transmission 

specifications referenced to 600 MHz. The cable end interface will probably be something other than 
the familiar RJ45 connector, mainly to differentiate the category 7 installation from existing lower-
bandwidth infrastructure. Because of the higher costs associated with manufacturing and installing 
these shielded products, their scope of usability is extremely limited in North America (<1%).

So, which should you use? There is quite a bit of misleading information in the industry on this subject, 
the biggest myth being that category 6 is required to run Gigabit Ethernet over copper (1000Base-T). 
However, as of this writing, the TIA recommends category 6 or category 5e as the minimum cabling for 
new network infrastructure installations.

When do I use category 6 or 6A? Does the application standard (i.e., Gigabit Ethernet, 10G, etc.) specify 
category 6 as a minimal requirement? As of this writing, the TIA and IEEE 802.3an committee have 
ratified standards for 10 Gigabit Ethernet over UTP. This standard requires an Augmented category 6 
system to run the standard 100 meters length. The good news is that Augmented category 6, as is the 
case with all TIA standards, is backward compatible and will have no trouble running existing applications 
such as 10/100Base-T and 1000Base-T.

The category 6A System is TE’s version of Augmented category 6. It provides not only support for the 
transmission protocols of today, such as 10/100/1000 Mbps, but also that of 10GBASE-T. It is worth 
noting that the complexity of Category 6A is transparent to the end user and installer. The products 
have simply been modified to overcome the shortcomings of standard category 6 to achieve the desired 
signal to noise ratios, taking into account bundled crosstalk, to achieve all of the current IEEE 802.3an 
(10GBASE-T) requirements.

Sc8_TechReference_v1.indd   23

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-24

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

CABLE TYPE SUMMARY

The chart below summarizes the industry standard UTP cable types used in current 
networking installations. 

SHIELDED VS. UNSHIELDED TWISTED PAIR

TE Connectivity offers both shielded and unshielded cables. Unshielded twisted pair (UTP) cabling provides 
immunity to electromagnetic interference (EMI) with the properties of the two conductors that make up a 
transmission pair being twisted together. When UTP cabling encounters electrical interference, the noise 
crossing the twisted pairs is cancelled by the twists in the cable (called “Common Mode Rejection,” a 
subject outside the scope of this discussion).

Standard category 5e, 6 and 6A cables are available in both shielded and unshielded versions and contain 
four unshielded twisted pairs that may or may not be shielded. For 10BASE-T and 100BASE-TX applications, 
only two pairs are used, one for the transmit circuit and one for receive circuit. For 1000BASE-T and 
10GBASE-T all four pairs are required.

There are actually two methods of shielding a twisted pair cable. Foiled twisted pair cable (F/UTP) provides 
an overall screen or metal foil around the four pairs of conductors, but each individual twisted pair is 
unshielded. Shielded twisted pair cable (S/FTP) has each individual pair shielded, plus an overall screen 
around the four individually shielded pairs. The legacy token ring IBM Type 1 cable and category 7 are 
examples of STP cable. STP cable requires metal encapsulated connectors that bond the cable shield to the 
telecommunications ground, in order to carry the interfering signals safely away from the signal conducting 
pairs. Throughout the industry, there is a misconception that grounding and bonding of shielded twisted-
pair (STP) copper cabling systems is more difficult, more time consuming, and more technique sensitive. 
This is simply not true. Properly grounding and bonding an STP copper cabling system is straightforward 
and essentially no different than grounding and bonding a UTP system. 

STRANDED VS. SOLID CONDUCTOR CABLE

Stranded cable is flexible and often used for patch panel jumpers and work area connections. 
Stranded cabling is used for shorter patching applications for its flexible cable construction, but also 
exhibits higher attenuation due to the smaller diameter conductors, and as such should not be used for long, 
permanent installations. Solid conductor cable is used for the “horizontal” cable runs. The typical gauge 
for category 5e cable is 24 AWG. Category 6/6A is 23 AWG—the larger conductor diameter improves 
attenuation characteristics and signal-to-noise ratio versus the smaller conductor diameter of category 5e.

In addition to the UTP cabling described above, you should understand the issues of cable 
shielding, and stranded versus solid cable.

Category

Test Frequency

10/100BaseT

1000BaseT

10 GBASE-T

Relative Cost

Cat 5e

100 MHz

Yes

Yes

No

$

Cat 6

250 MHz

Yes

Yes

No

$$

Cat 6A

500 MHz

Yes

Yes

Yes

$$$

Cat 7

600 MHz

Yes

Yes

Yes

$$$$

Sc8_TechReference_v1.indd   24

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-25

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

CHOOSING THE RIGHT ETHERNET PATCH PANELS

There are two predominant types of IDCs on the market today, the 110 and the Angled IDC Technology. 
Many manufacturers have now started to migrate to a 45° IDC due to its superior technical advantages, 
such as lower resistance, torsional forces, better stability when vibrated and the ability to accept multiple and 
stranded conductors. 

For patch-panel-to-patch-panel connections in a data center or telecommunications room, preterminated 
cable assemblies and connectorized patch panels can improve installation time and connectivity success. 
A preconnectorized solution dramatically decreases the assembly time and increases the quality of the 
termination, as the contact’s points are typically gold-on-gold with high contact forces. Preconnectorized 
solutions do require up-front planning—the distances between panels must be determined so the correct cable 
assembly length can be ordered.

RJ45-to-RJ45 and RJ45-to-RJ-21X panels are the two most popular preconnectorized systems. The 
RJ-21X, also known as 50-pin telco or 25-pair Amphenol connectors, is popular because six 4-pair Ethernet 
(1000BaseT) or twelve 2-pair Ethernet (10/100BaseT) circuits can be terminated at one time on a panel 
using the correct multi-pair cable assembly. The main requirement for 25-pair cable and connectors is the 
PowerSum NEXT or PSNEXT requirement.

Patch Panel Rear Termination Options
 

Popular choices for patch panel rear terminations include insulation displacement contact (IDC) punchdown 
termination, and connectorized cable end terminations (RJ45 and RJ-21X).

Many popular data patch panels are designed using IDCs, requiring the manual punchdown termination of 
each individual wire. A typical 24-port panel requires 192 individual punchdown terminations. With this many 
manual terminations, installation mistakes are common, including incorrect wire mapping (cross-wiring), opens, 
shorts, and excessive untwisting of the wire pairs. Terminating the “horizontal” cabling room typically uses IDC 
punchdown panels.

Sc8_TechReference_v1.indd   25

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-26

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

CABLE MANAGEMENT

Careful attention should be paid to the cable management scheme that surrounds patch panels and 
Ethernet equipment. Ideally, all Ethernet equipment is permanently terminated in a cross-connect field so 
that moves, adds, and changes (MACs) are done using patch cords. This enables circuit rerouting, upgrades 
for Ethernet equipment, and routine maintenance with less downtime—and less chance for damaging active 
equipment ports and cables. At a minimum, the Ethernet network should include the following characteristics:

• 

Access to cables.

 Especially as rack density increases, it is important that cables can be easily 

identified and traced for MACs. Otherwise, simple rearrangements turn into hours of technician time 
and downtime.

• 

Cable routing. 

Establishing defined cable routing paths within racks, between racks, and between 

equipment rooms ensures that patch cords and cables remain organized and neat. This increases both 
the service life of cables and the availability of Ethernet services for users.

• 

Physical protection and storage.

 Cables dangling from overhead or laying the floor invite problems. 

The proper method is to provide storage within each rack so that inadvertent damage and downtime 
is avoided.

Sc8_TechReference_v1.indd   26

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-27

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

KEY FIBER OPTIC CABLE MANAGEMENT CONCEPTS

Proper cable management practices make fiber networks less susceptible to accidental damage, quicker to 
install, less expensive to own and operate over the long haul and easier to expand as needs grow.

Key cable management concepts include:

• 

Bend radius:

 At turns in fiber runs, maintain a 1.5 inch bend radius. Tighter bends may cause macro-

bending of individual fibers that allow light to escape the signal path, resulting in signal attenuation. More 
severe bends can break fiber strands completely, resulting in signal loss.

• 

Cable troughing: 

Used to route fiber optic cable, troughing systems provide a protected pathway for fiber 

to traverse spans between rooms and equipment racks. Good troughing systems will keep fiber separate 
from copper cable, protect it from out-of-tolerance bends and promote neat, easily accessible runs.

• 

Vertical cable protection: 

Allowing fiber to hang unprotected from the back of equipment can be a recipe 

for disaster. Exposed cables are easy to snag accidentally with a hand or foot, which can result in damage 
to the connector or fiber itself. Additionally, over time the weight of hanging fiber can cause bends outside 
the acceptable limit and consequently, damage to the fiber. Proper vertical cable management in panels or 
equipment bays provides adequate support, cable protection and a transition from the vertical run to the 
back of the equipment that does not damage the fiber.

• 

Cable pile-up:

 In horizontal fiber runs, it is unacceptable to allow a pile of fiber cable to exceed two 

inches. Beyond that point, the weight of the bundle will surpass the crush tolerance limit of the fiber at the 
bottom of the stack, resulting in microscopic damage and signal attenuation.

• 

Cable segregation:

 Keep fiber runs separate from legacy copper cable. Copper cable is relatively heavy 

and can crush fiber cables. Additionally, segregating coax from fiber ensures that technicians repairing 
coax do not accidentally damage the fiber cable while working on the copper.

• 

Labeling:

 As you would in a legacy copper environment, develop good labeling practices. Know 

where fibers originate and terminate. Doing so will reduce maintenance time and the likelihood that a 
maintenance tech will make hasty decisions on fiber routing that can lead to a rat’s nest of cable and 
patch cords.

• 

Density: 

When selecting products for a fiber network, remember future maintenance. The more densely 

connectors are packed onto a panel, the more difficult it will be for even the most dexterous technicians to 
maintain. Remember, inevitably cables will be moved, so the ability to trace and re-route them is critical to 
working efficiently.

• 

Future proofing:

 When planning rack configurations with a given number of terminations to accommodate 

a relatively low number of fibers for today’s requirements, don’t forget the future. A fiber path that easily 
supports 12 fibers today may be inadequate to support the 200 fibers needed in a few years. Planning up 
front for the future can save the expense of ripping out outgrown capacity down the road.

Proper cable management is extremely important to the success of an evolving high-performance 
communications network. The fact that a single fiber may transmit mission-critical signals underlies the 
importance of taking the steps necessary to manage fiber’s installation and use.

Sc8_TechReference_v1.indd   27

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-28

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

SINGLEMODE VERSUS MULTIMODE FIBER

Fiber optic cable comes in two varieties: singlemode and multimode. Both have applications in structured cabling 
applications. Singlemode fiber optic cables transmit a single ray of light used to carry modulated signals. It is 
normally used in applications requiring the transmission of signals over a long distance, for example, between 
separate facilities on a campus.

Multimode fiber optic cable carries multiple light rays with different reflection angles within the fiber core. With a 
fiber core that’s larger in diameter than singlemode fiber, multimode cable is better suited for short runs, such as 
those between equipment and panels. Multimode should be used to connect devices such as optical routers and 
servers.

Fiber optic cable offers a level of security that exceeds copper or microwave transmission because it is difficult to 
tap without breaking.

ULTRA PHYSICAL CONTACT CONNECTORS AND ANGLED PHYSICAL CONTACT CONNECTORS

Attaching a connector to a fiber optic cable will cause some of the light traversing that fiber to be lost. Regardless 
of whether the connector was installed in the factory or the field, its presence will be responsible for some light 
being reflected back towards its source, the laser. Commonly known as return loss (RL), these reflections can damage 
the laser and degrade the signal’s performance. The degree of signal degradation caused by RL depends on the 
laser’s specifications; some lasers are more sensitive to RL than others.

The amount of optical return loss generated is related to the type of polish that is used on the connector.

The 

angled physical contact

 (APC) connector is best for high bandwidth applications and long haul links since it 

offers the lowest return loss characteristics of connectors currently available. In an APC connector, the endface of 
a termination is polished precisely at an eight degrees angle to the fiber cladding so that most RL is reflected into 
the cladding where it cannot interfere with the transmitted signal or damage the laser source. As a result, APC 
connectors offer a superior RL performance of -65 dB.

However, it is extremely difficult to field terminate an angled physical contact connector at eight degrees with any 
consistent level of success. Therefore, if an APC connector is damaged in the field it should be replaced with a 
factory-terminated APC connector.

The 

ultra physical contact

 (UPC) connector—while not offering the superior optical return loss performance of an 

APC connector—has RL characteristics that are acceptable for data transmissions. When using UPC connectors, 
make sure your laser’s specifications can handle the return loss your UPC connectors will generate.

Offering –57 dB RL, ultra physical contact connectors rely on machine polishing to deliver their low optical return 
loss characteristics. Ultra physical contact polishing refers to the radius of the endface polishing administered to the 
ferrule, the precision tube used to hold a fiber in place for alignment. The rounded finish created during the polishing 
process allows fibers to touch on a high point near the fiber core where light travels. Unlike APC connectors, UPC 
connectors can, with the proper tools and training, be repaired in the field.

Sc8_TechReference_v1.indd   28

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

Technical Reference

Industry Standards

8-29

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

TECHNICAL REFE

R

ENCE

  

CONNECTOR STYLES 

• 

SC:

 The SC style offers excellent loss characteristics and comes in a standard footprint. It 

is easy to snap in and remove. The SC is pull-proof and is available in UPC and APC. 

• 

LC: 

The most popular of all connectors, the LC is a small-form-factor connector. The LC features are 

similar to SC, but its size allows double the density. Available in UPC and APC.

• 

ST®:

 Very similar in appearance to a BNC connector, the ST is a bayonet type connector. It does not 

offer the pull-proof resiliency of SC and LC connectors. ST connectors, which are made of metal 
components, are only available with UPC polishing. In recent years, the popularity of ST connectors 
has waned as the use of SC and LC connectors has grown.

• 

Duplex SC:

 Offers the same features as the SC style but supports two-way communication.

• 

MT-RJ:

 Each MT-RJ fiber connector houses two fibers and is less than half the size of SC duplex 

connector and transceiver, doubling the port density of fiber-optic LAN equipment. 

When designing a fiber network for routing signals through a facility, standardizing on a single 
connector type will make network repairs and technician training faster and less expensive. However, 
despite efforts to standardize on a single connector style, it may be necessary to use a hybrid cable in 
some applications.

POLARITY MADE SIMPLE

One of the most common questions regarding MPO deployment is how the system design addresses 
the polarity issue of the fiber. TE's TrueNet system employs the recommendations made in TIA standard 
TIA-568-C.3.
TrueNet plug-and-play trunks use a key up/key down fiber array as noted in TIA-568-C.3. The TrueNet 
plug-and-play cassettes are wired straight through. In addition, TrueNet duplex jumpers have a duplex 
clip that easily removed for polarity changes in the field.

Sc8_TechReference_v1.indd   29

12/7/12   4:01 PM

Tyco-catalog-AMP-2013-html.html
background image

9-1

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74063/12123456AE

Index

By Product Name ...........................................................................................

9-3

By Part Number ...............................................................................................

9-15

Sc9_Index_v1.indd   1

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Product Name

9-3

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

TOC

FIBER ........................................................................................................ Section 1
SECURE NETWORK SOLUTIONS ...........................................Section 2
COPPER  .................................................................................................Section 3
WORK AREA OUTLETS ................................................................Section 4
MANAGED CONNECTIVITY ........................................................Section 5
CABLE MANAGEMENT .................................................................Section 6
SUPPLEMENTARY SOLUTIONS ...............................................Section 7
TECHNICAL REFERENCE ............................................................Section 8
INDEX  .....................................................................................................Section 9

1

110Connect Modular Jack Patch Panels .......................................... 3-84
110Connect XC Cable Management .................................................. 3-49
110Connect XC Category 5e Cable Assemblies .......................... 3-45
110Connect XC Category 5e Connecting Blocks........................ 3-46
110Connect XC Category 5e Cross-Connect Distribution  
 

Frame Kits ............................................................................................. 3-48

110Connect XC Category 5e Cross-Connect Rack Mount  
 

Panel ........................................................................................................3-50

110Connect XC Category 5e Kits .........................................................3-47
110Connect XC Category 5e Wiring Blocks .................................. 3-46
110 Punch Down Tool Replacement Blades................................... 3-116
110 Punch Down Tools with Blades .................................................... 3-116
12-Port Universal Surface Mount Outlet ............................................4-13
16-Port Compact Ethernet Switch ......................................................3-75
1RU Rack Mount Fiber Optic Patch Panel .......................................3-85

2

2x2 Direct Support Kits ............................................................................  6-5
2x2 Downspout Options ..........................................................................  6-5
2x2 Fittings and Junctions .....................................................................   6-4
2x2 Straight Section ..................................................................................   6-4
2x2 Track Support Kits ..............................................................................  6-5
2x6 Fittings .....................................................................................................   6-6
2x6 Straight Section ..................................................................................   6-6
2x6 Support Kits ..........................................................................................   6-8
24-Port Smart Ethernet Switch II with Optional Dual  

Uplink Port ...........................................................................................3-75

24-Port Stackable Managed Switch with Optional  
 

Expansion Port ..................................................................................3-76

25-Pair Cable Color-Coding ....................................................................8-17
25-Pair Conductor Color Code .............................................................3-37

4

4-Pair Conductor Color Code ................................................................. 3-6
4x4 Downspout Options .........................................................................   6-8
4x4 Fittings and Junctions .....................................................................  6-7
4x4 Straight Section...................................................................................  6-7
4x4 Support Kits .........................................................................................   6-8
4x6 Downspout Options .........................................................................   6-8
4x6 Fittings ....................................................................................................   6-9

4x6 Junctions ................................................................................................   6-9
4x6 Straight Section ..................................................................................   6-9
4x6 Support Kits .........................................................................................   6-8
4x12 Fittings ..................................................................................................  6-10
4x12 Junction ................................................................................................  6-10
4x12 Straight Section ...............................................................................  6-10
4x12 System Support Kits .......................................................................   6-11
4x24 Snap-Fit Junction ..........................................................................   6-13
4x24 System Downspouts – 4" H x 24" W ...................................  6-14
4x24 System Fittings – 4" H x 24" W ..............................................  6-14
4x24 System - Straight Section..........................................................   6-13
4x24 System Support Kits ....................................................................   6-15

5

5-Port Compact Ethernet Switch ........................................................3-75
50/125 

µ

m OM1 Multimode MT-RJ Transition Point Cable  

 

Assemblies ............................................................................................ 3-99

50/125 

µ

m OM2 Multimode Epoxy/Polish Connectors ............1-40

50/125 

µ

m OM2 Multimode LightCrimp PLUS Connectors  

 

(No epoxy/No polish) .......................................................................1-35

50/125 

µ

m OM2 Multimode MT-RJ Jacks  

 

(No epoxy/No polish) ...................................................................... 1-44

50/125 

µ

m OM2 Multimode Optical Fiber Interconnect  

 

Cable ...............................................................................................1-20, 1-23

50/125 

µ

m OM2 Multimode Snap-in Adapter Plates ..................1-48

510 Series, Category 5e UTP Cable ....................................................3-35
520 Series, Category 5e F/UTP Cable ..............................................3-33
520 Series, Category 5e UTP Cable ...................................................3-32

6

62.5/125 m OM1 Multimode MT-RJ Jacks  

(No epoxy/No polish) .......................................................................1-45

62.5/125 

µ

m OM1 Multimode  Adapters .............................................1-52

62.5/125 

µ

m OM1 Multimode Couplers ...............................................1-52

62.5/125 

µ

m OM1 Multimode Epoxy/Polish Connectors ............1-41

62.5/125 

μ

m OM1 Multimode LC Test Kits .......................................1-140

62.5/125 

µ

m OM1 Multimode LightCrimp PLUS Connectors  

 

(No epoxy/No polish) .......................................................................1-36

62.5/125 

µ

m OM1 Multimode Optical Fiber Interconnect  

 

Cable ...............................................................................................1-20, 1-23

62.5/125 

μ

m OM1 Multimode Replacement Components  

 

for LC Test Kits ...................................................................................1-140

62.5/125 

µ

m OM1 Multimode Snap-in Adapter Plates ............... 1-49

610 Series, Category 6 UTP Cable .......................................................3-19
620 Series, Category 6 UTP Cable ......................................................3-17
630 Series, Category 6E UTP Cable ...................................................3-16
640 Series Category 6A F/UTP Twisted Pair Cable ................... 3-3
640 Series Category 6A U/UTP Twisted Pair Cable ...................3-4

8

8-Port Compact Ethernet Switch ........................................................3-75
8-Port PoE Midspan Device ....................................................................3-79

Sc9_Index_v1.indd   3

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Product Name

9-4

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

A

Accessories ........................................................................................................4-3
Adapter for 89B Bracket ..........................................................................3-47
Adapters for Furniture Faceplates .....................................................4-20
Advanced Purchased License .............................................................3-103
Aerial Panel Holder Kit for Wire Mesh Cable Trays ....................3-67
AMP-BARREL Wire Insertion Tools .................................................. 3-122
AMP NETCONNECT Labeling Software ........................................3-104
AMP-TY Nylon Cable Ties ........................................................... 1-137, 3-101
Angled Faceplates .................................................................1-119, 4-6–4-24
Angled Panels .................................................................................................. 3-8
Armored Cable ...............................................................................................1-115
Array Cables, High Fiber Plug-and-Play ..............................................1-5
Assembly Length ............................................................................................ 1-8

B

Backbone Cabling..........................................................................................8-11
Blades: LC-to-LC, LC-to-MPO, MPO-to-MPO .................................. 5-9
Blank Chassis Covers ....................................................................................5-7
Blank Panels ....................................................................................................3-82
Breakout Length .............................................................................................. 1-8
Broadcast Products .......................................................................................7-3

C

Cable Assemblies .......................................................................................3-107
Cable Assembly Configuration .................................................................1-7
Cable Clamping/Block Conversion Kits ............................................1-83
Cable Clamp Kit .............................................................................................1-88
Cable Cutters ................................................................................................. 3-118
Cable Installation ...........................................................................................8-15
Cable Management ...............................................................................................

2x2 Direct Support Kits ..................................................................  6-5
2x2 Downspout Options ................................................................  6-5
2x2 Fittings and Junctions ...........................................................   6-4

 

2x2 Straight Section ........................................................................   6-4

 

2x2 Track Support Kits ....................................................................  6-5

 

2x6 Fittings ..........................................................................................   6-6

 

2x6 Straight Section ........................................................................   6-6

 

2x6 Support Kits ...............................................................................   6-8

 

4x4 Downspout Options ..............................................................   6-8

 

4x4 Fittings and Junctions ...........................................................  6-7

 

4x4 Straight Section ........................................................................  6-7

 

4x4 Support Kits ...............................................................................   6-8

 

4x6 Downspout Options ..............................................................   6-8

 

4x6 Fittings ..........................................................................................   6-9

 

4x6 Junctions .....................................................................................   6-9

 

4x6 Straight Section .......................................................................   6-9

 

4x12 Fittings ........................................................................................  6-10

 

4x12 Junction .....................................................................................  6-10

 

4x12 Straight Section .....................................................................  6-10

 

4x12 System Support Kits ............................................................   6-11

 

4x24 Snap-Fit Junction ................................................................   6-13

4x24 System Downspouts – 4" H x 24" W .........................  6-14
4x24 System Fittings – 4" H x 24" W ....................................  6-14
4x24 System - Straight Section ...............................................   6-13
4x24 System Support Kits ..........................................................   6-15
Cable Support Bars .......................................................................  6-25
C-LOK, Solid and Stranded Copper Bonding  

Connectors ...............................................................................  6-25

Double-Sided High-Density Vertical Cable Managers   6-20

 

Equipment Racks .............................................................................  6-18

 

Express Exits Units ...........................................................................   6-4

 

Fiber Cable Raceway Accessories ..........................................   6-12

 

Fiber Cable Raceway FiberGuide Systems ..........................  6-3

 

FiberGuide Materials Product Statement ...........................   6-17

 

Grounding Lug Kit ..........................................................................  6-25

 

High-Density Cable Management Accessories ................  6-21

 

Hinged Patch Panel Accessories ............................................  6-23

 

Hinged Wall Brackets for 19-Inch Panels ............................  6-23

 

Horizontal Finger Duct Accessories .....................................  6-22

 

Horizontal Finger Duct Panels .................................................  6-22

 

Horizontal Ringed Cable Management Panels ...............  6-24

 

MRJ21 Cable Support Bars ........................................................  6-26

 

Rack Mount Cable Trough ..........................................................  6-24

 

Rack Mount Mounting Frames ................................................  6-34

 

Rod Mount Bracket Spacer .......................................................  6-33
Solid Copper Bonding Connectors .......................................  6-25
Stationary, Ventilated Shelf ........................................................  6-19

 

Stranded Copper Bonding Connectors ..............................  6-25
Termination Block Mounting Hardware ..............................  6-26
Type 85 Back Mount Frames .....................................................  6-31

 

Type 85 Rod Mount Brackets ...................................................  6-32
Type 105 Back Mount Frames ...................................................  6-31

 

Type 105 Back Mount Frames with Ground Lug ............  6-32

 

Type 105 Rod Mount Brackets .................................................  6-33

 

Universal Mounting System (UMS)........................................  6-27

 

Universal Mounting System (UMS) Backboards ............  6-29

 

Universal Mounting System (UMS) Cable ..........................  6-28

 

Universal Mounting System (UMS) High Volume Cable  

 

 

Managers ..................................................................................   6-30

 

Universal Mounting System (UMS) Wire Managers .....  6-28

 

Vertical Duct Systems ....................................................................   6-11

 

Vertical Finger Duct Panels .......................................................  6-22

 

Wall Mount Mounting Frames ..................................................  6-34

Cable Strippers ............................................................................................. 3-118
Cable Support Bars ........................................................................ 3-58, 6-25
Category 3 25-Pair Patch Panels ..........................................................3-81
Category 3 Modular Plugs ...................................................................... 3-88
Category 3 Patch Panels .........................................................................3-80
Category 5, 10/100BASE-T, RJ21 (25-Pair) Patch Panel  

and Cable Assemblies ..................................................................3-80

Category 5e, 6 and 6A Cabling ............................................................8-23
Category 5e Cable Assemblies ............................................................3-44
Category 5e Couplers ...............................................................................3-40
Category 5e Modular Jacks ...................................................................3-40

Sc9_Index_v1.indd   4

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Product Name

9-5

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

Category 5e Modular Plugs ................................................................... 3-42
Category 5e Patch Cords .........................................................................1-116
Category 5e Patch Panels .......................................................................3-38
Category 5e Termination Blocks ......................................................... 3-45
Category 5e Twisted Pair Cable ...........................................................3-32
Category 5e UTP Solution ..................................................................... 3-125
Category 6, 8-Position Modular Plug ................................................3-24
Category 6A 8-pair Termination Block Patch Cords .................3-15
Category 6A 8-pair Termination Blocks ...........................................3-13
Category 6A 20-pair Termination Block Patch Cords ..............3-15
Category 6A 20-pair Termination Blocks ........................................3-13
Category 6A Modular Jacks ..................................................................... 3-9
Category 6A Patch Cords ........................................................................1-118
Category 6A Patch Panels .........................................................................3-7
Category 6A Shielded Cable Assemblies ......................................... 3-11
Category 6A Shielded Patch Cable Assemblies .........................3-53
Category 6A Shielded Solution .......................................................... 3-128
Category 6A Termination Blocks ..........................................................3-14
Category 6A UTP Solution ....................................................................3-127
Category 6A U/UTP Cable Assemblies ............................................3-12
Category 6 Cable Assemblies ...............................................................3-25
Category 6 Couplers ..................................................................................3-23
Category 6 Modular Jacks ......................................................................3-23
Category 6 Patch Cords ............................................................................1-118
Category 6 Patch Panels ...............................................................3-21–3-22
Category 6 Termination Blocks ................................................3-26–3-27
Category 6 Twisted Pair Cable ..............................................................3-16
Category 6 UTP Solution ....................................................................... 3-126
Clear Label Holder for 110Connect XC Wiring Blocks ............3-107
C-LOK Copper Bonding Connectors ..............................................  6-25
CM2-U2AMP ....................................................................................................4-15
CM2-U2AMP-BK ............................................................................................4-15
CM2-U2AMP-G ...............................................................................................4-15
CM2-U2AMP-GY ............................................................................................4-15
CM2-U2AMP-WH ..........................................................................................4-15
Concealed ONT Kit .....................................................................................1-123
Configuration Information ........................................................................ 1-77
Consolidation Points for Drop Ceiling Systems .......................... 3-96
Consolidation Points for Raised Floor Systems.......................... 3-95
Consolidation Point Transition Cable Assemblies .........1-123, 3-98
Consumables Kits .......................................................................................1-130
Copper 
 

1RU Rack Mount Fiber Optic Patch Panel ..........................3-85

 

4-Pair Conductor Color Code ..................................................... 3-6

 

5-Port Compact Ethernet Switch ...........................................3-75

 

8-Port Compact Ethernet Switch ...........................................3-75

 

8-Port PoE Midspan Device .......................................................3-79

 

16-Port Compact Ethernet Switch ..........................................3-75

 

24-Port Smart Ethernet Switch II with Optional Dual  

 

 

Uplink Port ...................................................................................3-75

 

24-Port Stackable Managed Switch with Optional  

 

 

Expansion Port ..........................................................................3-76

 

25-Pair Conductor Color Code .................................................3-37

 

50/125 

µ

m OM1 Multimode MT-RJ Transition Point  

 

 

Cable Assemblies ................................................................... 3-99

 

110Connect Modular Jack Patch Panels .............................. 3-84

 

110Connect XC Cable Management ...................................... 3-49

 

110Connect XC Category 5e Cable Assemblies .............. 3-45

 

110Connect XC Category 5e Connecting Blocks ........... 3-46

 

110Connect XC Category 5e Cross-Connect Distribution  

 

 

Frame Kits .................................................................................. 3-48

 

110Connect XC Category 5e Cross-Connect Rack  

 

 

Mount Panel ............................................................................... 3-50

 

110Connect XC Category 5e Kits .............................................3-47

 

110Connect XC Category 5e Wiring Blocks ...................... 3-46

 

110 Punch Down Tool Replacement Blades ...................... 3-116

 

110 Punch Down Tools with Blades ....................................... 3-116

 

510 Series, Category 5e UTP Cable ........................................3-35

 

520 Series, Category 5e F/UTP Cable ..................................3-33

 

520 Series, Category 5e UTP Cable.......................................3-32

 

610 Series, Category 6 UTP Cable ...........................................3-19

 

620 Series, Category 6 UTP Cable ..........................................3-17

 

630 Series, Category 6E UTP Cable .......................................3-16

 

640 Series Category 6A F/UTP Twisted Pair Cable ....... 3-3

 

640 Series Category 6A U/UTP Twisted Pair Cable ......3-4

 

Adapter for 89B Bracket .............................................................3-47

 

Advanced Purchased License .................................................3-103

 

Aerial Panel Holder Kit for Wire Mesh Cable Trays ........3-67

 

AMP-BARREL Wire Insertion Tools ..................................... 3-122

 

AMP NETCONNECT Labeling Software ............................3-104

 

AMP-TY Nylon Cable Ties ..........................................................3-101

 

Angled Panels ...................................................................................... 3-8

 

Blank Panels ........................................................................................3-82

 

Cable Assemblies ...........................................................................3-107

 

Cable Cutters .................................................................................... 3-118

 

Cable Strippers ................................................................................ 3-118

 

Cable Support Bars ........................................................................3-58

 

Category 3 25-Pair Patch Panels ..............................................3-81

 

Category 3 Modular Plugs ......................................................... 3-88

 

Category 3 Patch Panels .............................................................3-80

 

Category 5, 10/100BASE-T, RJ21 (25-Pair) Patch Panel  

 

 

and Cable Assemblies ..........................................................3-80

 

Category 5e Cable Assemblies ...............................................3-44

 

Category 5e Couplers ..................................................................3-40

 

Category 5e Modular Jacks ......................................................3-40

 

Category 5e Modular Plugs ....................................................... 3-42

 

Category 5e Patch Panels ...........................................................3-38

 

Category 5e Termination Blocks ............................................ 3-45

 

Category 5e Twisted Pair Cable ...............................................3-32

 

Category 5e UTP Solution ........................................................ 3-125

 

Category 6, 8-Position Modular Plug ....................................3-24

 

Category 6A 8-pair Termination Block Patch Cords .....3-15

 

Category 6A 8-pair Termination Blocks ...............................3-13

 

Category 6A 20-pair Termination Block Patch Cords ..3-15

 

Category 6A 20-pair Termination Blocks ............................3-13

 

Category 6A Modular Jacks ........................................................ 3-9

Sc9_Index_v1.indd   5

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Product Name

9-6

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

Category 6A Patch Panels .............................................................3-7

 

Category 6A Shielded Cable Assemblies ............................. 3-11

 

Category 6A Shielded Patch Cable Assemblies .............3-53

 

Category 6A Shielded Solution .............................................. 3-128

 

Category 6A Termination Blocks .............................................3-14
Category 6A UTP Solution ........................................................3-127
Category 6A U/UTP Cable Assemblies ................................3-12
Category 6 Cable Assemblies ...................................................3-25

 

Category 6 Couplers ......................................................................3-23
Category 6 Modular Jacks ..........................................................3-23
Category 6 Patch Panels ..................................................3-21–3-22

 

Category 6 Termination Blocks ....................................3-26–3-27
Category 6 Twisted Pair Cable ..................................................3-16

 

Category 6 UTP Solution ........................................................... 3-126

 

Clear Label Holder for 110Connect XC Wiring Blocks 3-107

 

Consolidation Points for Drop Ceiling Systems .............. 3-96

 

Consolidation Points for Raised Floor Systems ............. 3-95

 

Consolidation Point Transition Cable Assemblies ......... 3-98

 

Copper Connectivity Solutions - Accessories and  

 

 

Labels ..............................................................................................3-111

 

Cover for Angled Patch Panels ................................................3-83

 

Die Sets for Twisted Pair Applications ................................ 3-118

 

Discrete High-Density Angled SL Series Patch Panel ..3-83

 

Easy Access Zone (EAZ) Enclosure ..................................... 3-99

 

Ethernet Media Converters .........................................................3-74

 

External Strain Reliefs For Modular Plugs ......................... 3-43

 

Faceplate/Outlet Compatibility List .......................3-108–3-110

 

Fast Ethernet Media Converters ..............................................3-77

 

Feed Thru (FT) Block Test Cord ............................................. 3-93

 

Feed-Thru (FT) Field Assembly Kits ......................................3-91

 

Feed-Thru (FT) Termination Block Systems.....................3-90

 

Feed-Thru Termination Accessories ..................................... 3-89

 

Feed-Thru Termination Block System .................................. 3-89

 

Gigabit Ethernet Media Converters .......................................3-78

 

HighBand Patch Cords...................................................... 3-30–3-31

 

Icon Wheels.......................................................................................3-102

 

Identification Accessories .........................................................3-103

 

Identification Labels .....................................................................3-103

 

Insertion/Extraction Tools ......................................................... 3-123

 

Inserts for 110Connect Modular Jack Patch Panels .......3-85

 

Intelligent, Self-Adjusting Balun ...............................................3-72

 

Keystone Category 3 Modular Couplers ............................ 3-86

 

KRONE Insertion Tool ....................................................................3-117

 

Label Compatibility List ................................................3-108–3-110

 

Label Covers for Faceplates.....................................................3-105

 

Label Covers for Patch Panels ................................................3-106

 

Labels for 110Connect XC Cross-Connect Wiring 

 

 

Blocks ...........................................................................................3-107

 

Labels for Cable ..............................................................................3-107

 

Labels for Patch Panels ..............................................................3-106

 

Master RF Video Interface ..........................................................3-72

 

Media Converters .............................................................................3-73

 

Mid-Span POE ...................................................................................3-73

 

Mini Multi-User Outlet (MUO)................................................... 3-94

 

Modular and Cross-Connect Consolidation Points ........3-97

 

Modular Consolidation Point Modules ..................................3-97

 

Modular Plug Boots ....................................................................... 3-43

 

MPO/MPOptimate Coupler Quick-Fit Module ................ 3-66

 

MPOptimate to LC Quick-Fit Cassettes.............................. 3-65
MPOptimate to SC Quick-Fit Cassettes ............................. 3-66

 

MRJ21 1 GbE Cassettes................................................................. 3-56
MRJ21 1 GbE Patch Panels ...........................................................3-58
MRJ21 Cassette Panel (1GbE) ................................................... 3-56
MRJ21 Copper Cabling Solutions .............................................3-51
MRJ21 Label Holder Panels ........................................................ 3-59

 

MRJ21 Labels ..................................................................................... 3-59

 

MRJ21 Quick-Fit Cassettes ......................................................... 3-65
MRJ21 Ultra Slim Cable Assemblies .......................................3-55
MRJ21 XG (10 GbE) System ........................................................3-52

 

MRJ21 XG 19-Inch Patch Panel, 1RU, Straight ................... 3-54

 

MRJ21 XG Cassette Patch Panel ............................................. 3-54

 

MRJ21 XG to MRJ21 XG Cable Assemblies .........................3-53
Multimedia Integrated Cable Management SL Series  

Patch Panels ...............................................................................3-83

 

Multimedia SL Series Patch Panels .........................................3-82

 

Next Generation MRJ21 1GbE Assemblies ..........................3-57

 

Outback 520 Outdoor Series, Outdoor Category  

 

 

5e UTP Cable ............................................................................ 3-34

 

Outback 620 Series, Outdoor Category 6 UTP  

 

 

Cable ................................................................................................3-18

 

Outback 640 Series, Outdoor Category 6A UTP  

 

 

Cable ................................................................................................. 3-5

 

Palm Grip Hand Tool Kits ........................................................... 3-123

 

Palm Grip Tool ...................................................................................3-117

 

Paper Labels ..........................................................................3-113–3-114

 

Patch Cords for Feed-Thru (FT) ..............................................3-92

 

Patch Cords for Feed-Thru (FT) Blocks ............................. 3-93

 

Patch Cords for Ultim8 Blocks .................................... 3-28–3-29

 

Pistol Grip Tool for AMP-BARREL Edge  

 

 

Connectors ................................................................................ 3-122

 

Portable “Butterfly” Hand Tool (MI-1) for CHAMP  

 

 

25-Pair Connectors ............................................................... 3-123

 

Power Cordage .................................................................................3-72

 

Power over Ethernet Products .................................................3-74

 

PRO-CRIMPER III Hand Tool ..................................................... 3-118

 

Pro-Installer’s Modular Plug Hand Tool ..............................3-120

 

Pro-Installer’s Modular Plug Hand Tool Kits and  

 

 

Accessories .................................................................................3-121

 

Pro-Installer Twisted Pair Tool Kit .......................................... 3-116

 

QSFP/QSFP+..................................................................................... 3-68

 

QSFP/QSFP+ High Speed Copper Cable  

 

 

Assemblies ................................................................................. 3-69

 

Quick-Fit Fiber Modules .............................................................. 3-66

 

Rack Mount Media Converter Chassis System .................3-78

 

RJ45 Coupler Panel ........................................................................3-79

 

RJ45 Dust Cover ..............................................................................3-87

Sc9_Index_v1.indd   6

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Product Name

9-7

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

SFP+ ......................................................................................................... 3-68

 

SFP+ High Speed Copper Cable Assemblies .................... 3-69

 

Side-Mount Label Holder ...............................................................3-113

 

Sigma-Link ............................................................................................3-60

 

Sigma-Link Cat6A F/UTP Cable Assemblies ......................3-62

 

Sigma-Link Cat6 UTP Cable Assemblies ...............................3-61
Sigma-Link Patch Panel ..................................................................3-62

 

SL Series Category 3 Modular Jacks ...................................... 3-86

 

SL Series Category 5e Modular Jacks ...................................3-40
SL Series Modular Category 6 Jack Accessories..............3-24

 

SL Series Modular Coupler ............................................................3-41

 

SL Series Modular Jack Strain Relief .......................................3-87

 

SL Series Modular Jack Termination Accessories ............3-115

 

SL Series Modular Jack Termination Tool .............................3-115

 

Smart Ethernet Switches ...............................................................3-74

 

SNMP Managed Ethernet Switches .........................................3-74

 

Standard Labels for Outlets .......................................................3-104

 

Standard Panels .................................................................................... 3-8

 

STP Quick-Fit Modules .................................................................. 3-65

 

Subfloor Panel Holder Kit ..............................................................3-67

 

Switches ..................................................................................................3-73

 

Tooling Category 6 Modular Plugs .......................................... 3-119

 

Twisted Pair Cable Packaging Reference ................3-20, 3-36

 

Twisted Pair Testing Tools ........................................................... 3-124

 

Type 105 Hinged Label Holder ....................................................3-112

 

Type 105 Label Holder .....................................................................3-112

 

Type 105 Label Strip .........................................................................3-112

 

UCP Drawer Style Enclosure ...................................................... 3-64

 

UCP Patch Panel................................................................................ 3-64

 

Ultim8 1-Pair Patch Cords .................................................3-29–3-30

 

Ultim8 2-Pair Patch Cords ................................................3-29–3-30

 

Universal Connectivity Platform (UCP) ................................ 3-63

 

Universal Labels ................................................................................3-105

 

UTP Quick-Fit Modules .................................................................. 3-65

 

Velcro Cable Ties ...............................................................................3-101

 

Vertical Panel Mounting Brackets .............................................3-67

 

Video Distribution Hub ...................................................................3-72

 

Video Distribution System (VDS) ..............................................3-71

 

Wall/Furniture Mounting Bracket .......................................... 3-100

Copper and Fiber Labeling Software and Labeling  
 

Sheets...................................................................................................... 1-138

Copper Connectivity Solutions - Accessories and  
 

Labels ........................................................................................................3-111

Copper Design Technology ...................................................................... 8-3
Cover for Angled Patch Panels .............................................................3-83
Curing Sleeves ...............................................................................................1-132
Custom Modular Adapter Packs ...........................................................1-57
Cycle Life ............................................................................................................8-4

D

Data Center Optical Distribution Frame with Plug-and-Play  
 

Cassettes ...............................................................................................1-85

Data Center Optical Distribution Frame with Plug-and-Play  

Cassettes Specifications ....................................................1-86–1-87

Desktop Monuments ..........................................................1-122, 4-16–4-24
Die Sets for Twisted Pair Applications............................................. 3-118
Discrete High-Density Angled SL Series Patch Panel ..............3-83
Distributed Antenna Systems ...................................................................7-3
Door Kits ..............................................................................................................5-7
Double-Sided High-Density Vertical Cable Managers .........   6-20

E

Easy Access Zone (EAZ) Enclosure ................................................. 3-99
EB-17B .................................................................................................................1-55
EB-35B ................................................................................................................1-55
End Guard .........................................................................................................1-76
EPO-TEK 353ND Epoxy ............................................................................1-128
Epoxy Applicator Syringe ...................................................................... 1-129
Epoxy Curing Oven ....................................................................................1-130
Epoxy/Polish Compatibility Chart .......................................................1-125
Epoxy/Polish Connector Consumables ............................................1-125
Epoxy/Polish Connector Termination Tool Kits ...........................1-127
Epoxy/Polish Tool Kits .............................................................................. 1-124
Equipment Racks .......................................................................................  6-18
Ethernet Media Converters .....................................................................3-74
Express Exits Units .....................................................................................   6-4
Extenders for Furniture Faceplates ...................................... 4-20–4-24
External Strain Reliefs For Modular Plugs...................................... 3-43

F

Faceplate/Outlet Compatibility List....................................3-108–3-110
Faceplates ..........................................................................................................4-3
Faceplates for Herman Miller Furniture.............................................4-19
Faceplates for Mounting Straps .............................................................4-8
Faceplates for WIREMOLD Raceways .............................................. 4-14
Fast Ethernet Media Converters ..........................................................3-77
FDF-ACC146 ..............................................................................1-85, 1-87, 1-89
FEC-ACCCLMP01 ........................................................................................ 1-102
Feed Thru (FT) Block Test Cord ......................................................... 3-93
Feed-Thru (FT) Field Assembly Kits ...................................................3-91
Feed-Thru (FT) Termination Block Systems .................................3-90
Feed-Thru Termination Accessories .................................................. 3-89
Feed-Thru Termination Block System .............................................. 3-89
Fiber ..............................................................................................................................
 

50/125 

µ

m OM2 Multimode Epoxy/Polish  

 

 

Connectors ..................................................................................1-40

 

50/125 

µ

m OM2 Multimode LightCrimp PLUS Connectors  

 

 

(No epoxy/No polish) .............................................................1-35

 

50/125 

µ

m OM2 Multimode MT-RJ Jacks  

 

 

(No epoxy/No polish) ............................................................ 1-44

 

50/125 

µ

m OM2 Multimode Optical Fiber Interconnect  

 

 

Cable .....................................................................................1-20, 1-23

 

50/125 

µ

m OM2 Multimode Snap-in Adapter Plates ......1-48

 

62.5/125 m OM1 Multimode MT-RJ Jacks  

 

 

(No epoxy/No polish) .............................................................1-45

Sc9_Index_v1.indd   7

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Product Name

9-8

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

62.5/125 

µ

m OM1 Multimode  Adapters...................................1-52

62.5/125 

µ

m OM1 Multimode Couplers.....................................1-52

62.5/125 

µ

m OM1 Multimode Epoxy/Polish 

Connectors....................................................................................1-41
62.5/125 

μ

m OM1 Multimode LC Test Kits ..................1-140

62.5/125 

µ

m OM1 Multimode LightCrimp PLUS Connectors 

(No epoxy/No polish).............................................................1-36

62.5/125 

µ

m OM1 Multimode Optical Fiber Interconnect 

Cable.....................................................................................1-20, 1-23

62.5/125 

μ

m OM1 Multimode Replacement Components 

for LC Test Kits.........................................................................1-140

62.5/125 

µ

m OM1 Multimode Snap-in Adapter Plates..... 1-49

AMP-TY Nylon Cable Ties .............................................................1-137
Angled Faceplates..............................................................................1-119
Armored Cable.....................................................................................1-115
Array Cables, High Fiber Plug-and-Play....................................1-5
Assembly Length.................................................................................. 1-8
Cable Assembly Configuration.......................................................1-7
Cable Clamping/Block Conversion Kits..................................1-83
Cable Clamp Kit...................................................................................1-88
Category 5e Patch Cords ...............................................................1-116
Category 6A Patch Cords..............................................................1-118
Category 6 Patch Cords..................................................................1-118
Concealed ONT Kit ...........................................................................1-123
Configuration Information.............................................................. 1-77
Consolidation Point Transition Cable Assemblies............1-123
Consumables Kits .............................................................................1-130
Copper and Fiber Labeling Software and Labeling 

Sheets ........................................................................................... 1-138

Curing Sleeves.....................................................................................1-132
Custom Modular Adapter Packs.................................................1-57
Data Center Optical Distribution Frame with Plug-and-

Play Cassettes ............................................................................1-85

Data Center Optical Distribution Frame with Plug-and-

Play Cassettes Specifications..................................1-86–1-87

Desktop Monuments........................................................................1-122

 

Empty Splice Panels..........................................................................1-96

 

Empty Termination Panels.............................................................1-95

 

Empty Termination Splice Panels.............................................. 1-94

 

End Guard...............................................................................................1-76

 

EPO-TEK 353ND Epoxy .................................................................1-128

 

Epoxy Applicator Syringe ............................................................ 1-129

 

Epoxy Curing Oven..........................................................................1-130

 

Epoxy/Polish Compatibility Chart.............................................1-125

 

Epoxy/Polish Connector Consumables .................................1-125

 

Epoxy/Polish Connector Termination Tool Kits.................1-127
Fiber Enclosure Comparison ........................................................1-53
Fiber Main Distribution Frame (FMDF)................................... 1-74
Fiber Optic Accessories and Tooling ..................................... 1-124
Fiber Optic OM2 Solution ............................................................ 1-142
Fiber Optic OM4 Solution............................................................1-144
Fiber Optic Patch Cords ..................................................................1-14

 

Fiber Optic Singlemode Solution ............................................. 1-145

 

Fiber Optic Terminal Patch Cord Storage Panel ................ 1-75

 

Fiber Patch Cord Configurator ..................................................... 1-15

 

Fiber Termination Blocks ................................................................ 1-72

 

Fiber Termination Blocks (FTBs) ................................................1-83

 

Fiber Termination Blocks (FTBs) Unterminated  

 

 

(Adapter Only) ............................................................... 1-80–1-82

 

Fiber Trunk Configurator .................................................................. 1-6

 

Fiber Trunk Solutions ...........................................................................1-3

 

Five Simple Components .............................................................1-103

 

FL2000 ....................................................................................................1-93

 

FL2000 6pak Connector Plug-Ins .............................................1-97

 

FL2000 6pak Connector Plug-Ins with Adapters and  

 

 

Pigtails ............................................................................................1-98

 

Frame Installation Kit ........................................................................1-89

 

Free Labeling Software ................................................................. 1-138

 

Hand Held Optical Fiber Cleaver ...............................................1-127

 

HIDEAWAY Multimedia Outlets.................................................1-120

 

HIDEOUT Outlets ................................................................................1-121

 

HYSOL Epoxy-Tubes ....................................................................... 1-129

 

Inspection Microscope .....................................................................1-131

 

LC Connector Cleaner (In Bulkhead Cleaner) ................... 1-136

 

LC Style FTBs with Factory Terminated Stubs ...................1-79

 

LightCrimp PLUS Cable Holders .............................................. 1-126

 

LightCrimp PLUS LC/SC and LightCrimp Splice  

 

 

Termination Tool Kit............................................................... 1-124

 

LightCrimp PLUS Termination Tool Kits ................................1-125

 

LightCrimp Splice ...............................................................................1-38

 

Mini Plug-and-Play Splitter Modules.......................................1-109

 

MPO-MPO Cable Assemblies .......................................................1-114

 

MPO to MPO Polarity for Cable Assemblies .......................... 1-9

 

MTP/MPO IBC (In Bulkhead Cleaner) .................................... 1-134

 

MT-RJ Jack Termination Tool Kit .............................................. 1-126

 

Multimode (850/1300 nm) Optical Fiber Cable  

 

 

Performance Specifications ............................................... 1-30

 

Multimode Adapters...........................................................................1-51

 

Multimode Couplers ...........................................................................1-51

 

Multimode Epoxy/Polish Connectors ......................................1-39

 

Multimode Interlocking Armor Optical Fiber Distribution  

 

 

Cable ................................................................................................1-25

 

Multimode LightCrimp PLUS Connectors  

 

 

(No epoxy/No polish) .............................................................1-34

 

Multimode MT-RJ Jack Accessories (OM4, OM3, OM2,  

 

 

and OM1) ...................................................................................... 1-46

 

Multimode MT-RJ Jacks (No epoxy/No polish) .................1-43

 

Multimode Optical Fiber Distribution Cable ........................1-22

 

Multimode Optical Fiber Indoor/Outdoor Cable ...............1-26

 

Multimode Optical Fiber  

 

Interconnect Cable ..............................................................................1-19

 

Multimode Optical Fiber Outside Plant Armored (OSPA)  

 

 

Cable ................................................................................................1-29

 

Multimode Optical Fiber Outside Plant (OSP) Cable ......1-28

 

Multimode Optical Fiber Performance ................................... 1-30

Sc9_Index_v1.indd   8

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Product Name

9-9

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

Multimode Snap-in Adapter Plates ...........................................1-47
NEOCLEAN Stick Cleaner .............................................................1-135

 

OM2, OM1 and Singlemode Optical Fiber Indoor/Outdoor  

 

 

Cable ................................................................................................1-27

OM3 and OM4 (50/125 

µ

m) Multimode LightCrimp  

 

 

PLUS Connectors (No epoxy/No polish) .....................1-34

 

OM3 and OM4 (50/125 

µ

m) Multimode Optical Fiber  

 

 

Distribution Cable .....................................................................1-22

 

OM3 and OM4 (50/125 

µ

m) Multimode Optical Fiber  

 

 

Indoor/Outdoor Cable ...........................................................1-26

 

OM3 and OM4 (50/125 

µ

m) Multimode Optical Fiber  

 

 

Interconnect Cable ....................................................................1-19

 

OM3 and OM4 (50 

μ

m) and OM2 (50/125 

μ

m) Multimode  

 

 

LC Test Kits ................................................................................ 1-139

 

OM3 and OM4 (50 

μ

m) and OM2 (50/125 

μ

m) Multimode  

 

 

Replacement Components for LC Test Kits ............. 1-139

 

OM3 and OM4 Multimode Epoxy/Polish Connectors .....1-39

 

OM3 and RMG OM4 (50/125 

µ

m) Multimode Snap-in  

 

 

Adapter Plates ............................................................................1-47

 

OMX Cable Clamps .......................................................................... 1-102

 

OMX Splice Cabinet .......................................................................... 1-101

 

OMX Splice Wheel ............................................................................ 1-102

 

Optical Distribution Frame ............................................................ 1-72

 

Optical Fiber Cables ..........................................................................1-113

 

Optical Fiber Cable Technical Information .................. 1-31–1-33

 

Optical Fiber Cable Temperature Ranges ..............................1-31

 

Optical LAN Solution ......................................................................1-106

 

OPTIPOP C Card Optical Connector Cleaner .....................1-135

 

OPTIPOP R Reel Optical Connector Cleaner ..................... 1-134

 

OS2 Singlemode Optical Fiber Interconnect  

 

 

Cable ......................................................................................1-21, 1-24

 

Polarity for MPO to MT-RJ, LC, SC, ST, or FC .......................1-10

 

Polishing Bushings ............................................................................1-132

 

Polishing Films ....................................................................................1-130

 

Pre-configured Termination/Splice Panels ............................1-99

 

PRO-CRIMPER III Fiber Die Sets ................................................1-133

 

PRO-CRIMPER III Fiber Optic Hand Tool ..............................1-133

 

Professional Fiber Connector Inspection/Cleaning  

 

 

Kits .................................................................................................. 1-136

 

Q3000 ......................................................................................................1-53

 

Q3000 Blades ......................................................................................1-54

 

Q3000 SAM Blades .........................................................................1-104

 

Rapid Fiber Distribution Hub (iFDH) .....................................1-108

 

Rapid Fiber Distribution Terminal ............................................. 1-110

 

Replacement Components for Singlemode LC Test  

 

 

Kits ....................................................................................................1-141

 

RMG ............................................................................................................1-55

 

RMG Empty Panels ............................................................................1-55

 

RMG Maximum Capacity by Adapter Style and Chassis  

 

 

Height...............................................................................................1-61

 

RMG Plug-and-Play Cassettes .....................................................1-59

 

RMG Pre-configured Panels with Adapters only or  

 

 

with Pigtails ..................................................................................1-58

 

RMG Product Overview .................................................................. 1-60

 

RMG Standard Adaptor Packs .....................................................1-56

 

SC Connector Cleaner (In Bulkhead Cleaner) ................... 1-136

 

SC style FTB's with Factory Terminated Stubs  

 

 

144-position Block ....................................................................1-78

 

Security Key Patch Cord .................................................................1-117

 

Security Key Plug ................................................................................1-116

 

Simplex Drop Cables .........................................................................1-112

 

Singlemode (1310/1550 nm) Optical Fiber Cable  

 

Performance Specifications ......................................................... 1-30

 

Singlemode Adapters .......................................................................1-52

 

Singlemode Couplers .......................................................................1-52

 

Singlemode Epoxy/Polish Connectors ....................................1-42

 

Singlemode LC Test Kits .................................................................1-141

 

Singlemode LightCrimp PLUS Connectors  

 

 

(No epoxy/No polish) .............................................................1-37

 

Singlemode Reduced Bend Radius Multifiber Cable  

 

 

Assemblies ...................................................................................1-114

 

Singlemode Snap-in Adapter Plates ....................................... 1-50

 

Sliding Adapter Packs ...........................................................1-72, 1-84

 

SL Series Faceplates .......................................................................1-120

 

Standard Cross-Connect Patch Cord Lengths ...................1-89

 

Storage Area Management .........................................................1-103

 

Strip Card Kit ........................................................................................1-132

 

TFP  ............................................................................................................1-62

 

TFP Empty Chassis ............................................................................1-63

 

TFP Fiber Panels ............................................................................... 1-107

 

TFP MPO Pack ....................................................................................... 1-71

 

TFP Plug-and-Play Cassettes ........................................... 1-68–1-69

 

TFP Pre-configured Termination/Splice Fiber Panels .....1-66

 

TFP Product Overview .....................................................................1-67

 

TFP Series Custom Adapter Packs ...........................................1-65

 

TFP Series Rack Mount Fiber Panels .......................................1-67

 

TFP Series Standard Adapter Packs ....................................... 1-64

 

Tool Kit Compatibility Chart ........................................................ 1-124

 

TRA-CON Epoxy ................................................................................1-128

 

Trunks, High Fiber Plug-and-Play ................................................. 1-4

 

Velcro Cable Ties ................................................................................1-137

 

Wall Boxes ...............................................................................................1-111

 

WMG ......................................................................................................... 1-90

 

WMG Standard Adapter Packs ....................................................1-91

Fiber Cable Raceway .................................................................................  6-3
Fiber Cable Raceway Accessories ....................................................   6-12
Fiber Cable Raceway FiberGuide Systems ....................................  6-3
Fiber Enclosure Comparison ..................................................................1-53
Fiberguide ........................................................................................................  6-3
FiberGuide Materials Product Statement .....................................   6-17
Fiber Main Distribution Frame (FMDF) ............................................. 1-74
Fiber Optic Accessories and Tooling ................................................ 1-124
Fiber Optic OM2 Solution ....................................................................... 1-142
Fiber Optic OM4 Solution ......................................................................1-144
Fiber Optic Singlemode Solution ....................................................... 1-145
Fiber Optic Terminal Patch Cord Storage Panel .......................... 1-75

Sc9_Index_v1.indd   9

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Product Name

9-10

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

Fiber Support Bar Kit ................................................................................ 3-95
Fiber Termination Blocks .......................................................................... 1-72
Fiber Termination Blocks (FTBs) ..........................................................1-83
Fiber Termination Blocks (FTBs) Unterminated  

(Adapter Only) ......................................................................... 1-80–1-82

Fiber Trunk Configurator............................................................................. 1-6
Fiber Trunk Solutions .....................................................................................1-3
FL2000  1-93
FL2000 6pak Connector Plug-Ins .......................................................1-97
FL2000 6pak Connector Plug-Ins with Adapters and  
 

Pigtails .......................................................................................................1-98

FL2000 Empty Splice Panels .................................................................1-96
FL2000 Empty Termination Panels ....................................................1-95
FL2000 Empty Termination Splice Panels ..................................... 1-94
FLEX-MODE Modular Furniture Faceplate  
 

Accessories ............................................................................. 4-20–4-24

Frame Installation Kit ..................................................................................1-89
Frames  1-72
Free Labeling Software ............................................................................ 1-138

G

Gigabit Ethernet Media Converters ....................................................3-78
Grounding Lug Kit ....................................................................................  6-25

H

Hand Held Optical Fiber Cleaver .........................................................1-127
HIDEAWAY Multimedia Outlets ...................................1-120, 4-10–4-24
HIDEOUT Outlets ................................................................... 1-121, 4-9–4-24
HighBand Patch Cords .................................................................. 3-30–3-31
High-Density Cable Management Accessories ..........................  6-21
Hinged Patch Panel Accessories ......................................................  6-23
Hinged Wall Brackets for 19-Inch Panels ......................................  6-23
Horizontal Cabling ........................................................................................8-12
Horizontal Finger Duct Accessories ...............................................  6-22
Horizontal Finger Duct Panels ...........................................................  6-22
Horizontal Ringed Cable Management Panels ..........................  6-24
How AirES Cable Technology Lowers Temperatures  
 

While Increasing Uptime .................................................................. 8-5

HYSOL Epoxy-Tubes ................................................................................. 1-129

I

ICM Software .................................................................................................... 5-6
Icon Wheels ...................................................................................................3-102
Identification Accessories ......................................................................3-103
Identification Labels .................................................................................3-103
Infrastructure Configuration Manager (ICM) ...................................5-4
Insertion/Extraction Tools ..................................................................... 3-123
Inserts for 110Connect Modular Jack Patch Panels ....................3-85
Inspection Microscope ...............................................................................1-131
Intelligent, Self-Adjusting Balun ...........................................................3-72

J

Jack Pin-Outs ..................................................................................................8-16

K

Keystone Category 3 Modular Couplers ......................................... 3-86
KRONE Insertion Tool ................................................................................3-117

L

Label Compatibility List .............................................................3-108–3-110
Label Covers for Faceplates .................................................................3-105
Label Covers for Patch Panels ............................................................3-106
Labels for 110Connect XC Cross-Connect Wiring Blocks .....3-107
Labels for Cable ..........................................................................................3-107
Labels for Patch Panels ...........................................................................3-106
LC Connector Cleaner (In Bulkhead Cleaner) ............................. 1-136
LC Duplex Clips ............................................................................................... 2-4
LC SECURE Duplex Hybrid Cable Assemblies ....................2-8, 2-10
LC SECURE Epoxy/Polish Simplex Connectors ............................ 2-4
LC SECURE LightCrimp PLUS Simplex Connectors  
 

(No expoxy/No polish) ..................................................................... 2-3

LC SECURE SL Series Duplex Couplers ............................................. 2-5
LC SECURE Snap-In Adapter Plates.................................................... 2-6
LC Style FTBs with Factory Terminated Stubs .............................1-79
LightCrimp PLUS Cable Holders......................................................... 1-126
LightCrimp PLUS LC/SC and LightCrimp Splice  
 

Termination Tool Kit ......................................................................... 1-124

LightCrimp PLUS No-epoxy/No-polish LC and SC Tool Kit 1-124
LightCrimp PLUS No-epoxy/No-polish ST Tool Kit .................. 1-124
LightCrimp PLUS No-epoxy/No-polish Universal Tool Kit.... 1-124
LightCrimp PLUS Termination Tool Kit ............................................ 1-124
LightCrimp PLUS Termination Tool Kits ..........................................1-125
LightCrimp Splice .........................................................................................1-38

M

Managed Connectivity ........................................................................................
 

Blades: LC-to-LC, LC-to-MPO, MPO-to-MPO ........................ 5-9

 

Blank Chassis Covers ..........................................................................5-7

 

Door Kits ....................................................................................................5-7

 

Q2000 Series Network Panels ....................................................5-15

 

Q4000 Series..........................................................................................5-7

 

QCC-4 Chassis Controller ...............................................................5-10

 

Q-Frame ...................................................................................................5-13

 

QPC-2 Panel Controller Compatible with Q2000  

 

 

Network Panels ..........................................................................5-15

 

Quareo Cross Connect Frame .....................................................5-13

 

Quareo Managed Array Cables .................................................... 5-11

 

Quareo Managed Fiber Cables ....................................................5-10

 

Quareo Managed Trunk and Array Cables ............................. 5-11

 

Quareo Series Network Chassis ....................................................5-7

Master RF Video Interface .......................................................................3-72
Media Converters .........................................................................................3-73
Mid-Span POE................................................................................................3-73
Mini Multi-User Outlet (MUO) ............................................................... 3-94
Mini Plug-and-Play Splitter Modules .................................................1-109
Modular and Cross-Connect Consolidation Points ....................3-97

Sc9_Index_v1.indd   10

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Product Name

9-11

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

Modular Consolidation Point Modules ..............................................3-97
Modular Jack Boxes ........................................................................4-14–4-24
Modular Plug Boots ................................................................................... 3-43
Modular Plug Boots for Category 6 Modular Plugs ..................3-25
Mounting Straps ................................................................................ 4-8–4-24
MPO Microcable Trunk Assembles .........................................................1-3
MPO-MPO Cable Assemblies .................................................................1-114
MPO/MPOptimate Coupler Quick-Fit Module............................. 3-66
MPOptimate to LC Quick-Fit Cassettes .......................................... 3-65
MPOptimate to SC Quick-Fit Cassettes.......................................... 3-66
MPO SECURE Optical Fiber Cassettes .............................................2-14
MPO SECURE to Non-SECURE LC Optical Fiber Cassettes ...2-7
MPO SECURE Trunk Cable Assemblies, Plenum (OFNP) .......2-15
MPO to MPO Polarity for Cable Assemblies .................................... 1-9
MRJ21 1 GbE Cassettes ............................................................................. 3-56
MRJ21 1 GbE Patch Panels .......................................................................3-58
MRJ21 Cable Support Bars ...................................................................  6-26
MRJ21 Cassette Panel (1GbE) ............................................................... 3-56
MRJ21 Copper Cabling Solutions ..........................................................3-51
MRJ21 Label Holder Panels .................................................................... 3-59
MRJ21 Labels ................................................................................................. 3-59
MRJ21 Quick-Fit Cassettes ..................................................................... 3-65
MRJ21 Ultra Slim Cable Assemblies....................................................3-55
MRJ21 XG (10 GbE) System ....................................................................3-52
MRJ21 XG 19-Inch Patch Panel, 1RU, Straight ............................... 3-54
MRJ21 XG Cassette Patch Panel .......................................................... 3-54
MRJ21 XG Quick-Fit Cassette 8 Port (10 Gb/s) ........................... 3-54
MRJ21 XG to MRJ21 XG Cable Assemblies .....................................3-53
MTP/MPO IBC (In Bulkhead Cleaner) .............................................. 1-134
MT-RJ Jack Termination Tool Kit ........................................................ 1-126
MT-RJ Jack Tool Kit.................................................................................... 1-124
MT-RJ, LC Adapters and SL .................................................................. 4-23
MT-RJ SECURE Hybrid Cable Assemblies........................................ 2-11
MT-RJ SECURE Outlet Jacks ....................................................... 2-12, 2-13
Multimedia Integrated Cable Management SL Series Patch  
 

Panels .......................................................................................................3-83

Multimedia Modules for Work Area Outlets ................................. 4-24
Multimedia SL Series Patch Panels .....................................................3-82
Multimode (850/1300 nm) Optical Fiber Cable  
 

Performance Specifications ......................................................... 1-30

Multimode Adapters .....................................................................................1-51
Multimode Couplers .....................................................................................1-51
Multimode Epoxy/Polish Connectors .................................................1-39
Multimode Interlocking Armor Optical Fiber Distribution  
 

Cable ..........................................................................................................1-25

Multimode LightCrimp PLUS Connectors (No epoxy/No  
 

polish) .......................................................................................................1-34

Multimode MT-RJ Jack Accessories (OM4, OM3, OM2, and  
 

OM1) .......................................................................................................... 1-46

Multimode MT-RJ Jacks (No epoxy/No polish) ............................1-43
Multimode Optical Fiber Distribution Cable ...................................1-22
Multimode Optical Fiber Indoor/Outdoor Cable .........................1-26
Multimode Optical Fiber Interconnect Cable ..................................1-19

Multimode Optical Fiber Outside Plant Armored (OSPA)  
 

Cable ..........................................................................................................1-29

Multimode Optical Fiber Outside Plant (OSP) Cable ................1-28
Multimode Optical Fiber Performance ............................................. 1-30
Multimode Snap-in Adapter Plates .....................................................1-47
MX6-BAYTEMPLATE .................................................................................. 1-101

N

NEOCLEAN Stick Cleaner .......................................................................1-135
Next Generation MRJ21 1GbE Assemblies ......................................3-57

O

OM1 (62.5/125 

μ

m) multimode LC cable assemblies ...................1-16

OM1 (62.5/125 

μ

m) multimode MTRJ cable assemblies ............1-16

OM1 (62.5/125 

μ

m) multimode SC cable assemblies ...................1-16

OM1 (62.5/125 

μ

m ) multimode ST cable assemblies ..................1-16

OM1 MPO Microcable Trunk Assemblies ..............................................1-3
OM2 (50/125 

μ

m) multimode LC cable assemblies .....................1-16

OM2 (50/125 

μ

m) multimode MTRJ cable assemblies ...............1-16

OM2(50/125 

μ

m) multimode SC cable assemblies ......................1-16

OM2 (50/125 

μ

m) multimode ST cable assemblies .....................1-16

OM2 MPO Microcable Trunk Assemblies ............................................1-3
OM2, OM1 and Singlemode Optical Fiber Indoor/Outdoor  
 

Cable ..........................................................................................................1-27

OM3 and OM4 (50/125 

μ

m) multimode LC cable  

 

assemblies................................................................................................1-16

OM3 and OM4 (50/125 

µ

m) Multimode LightCrimp PLUS  

 

Connectors (No epoxy/No polish) ............................................1-34

OM3 and OM4 (50/125 

μ

m) multimode MTRJ cable  

 

assemblies................................................................................................1-16

OM3 and OM4 (50/125 

µ

m) Multimode Optical Fiber  

 

Distribution Cable ...............................................................................1-22

OM3 and OM4 (50/125 

µ

m) Multimode Optical Fiber  

 

Indoor/Outdoor Cable ......................................................................1-26

OM3 and OM4 (50/125 

µ

m) Multimode Optical Fiber  

 

Interconnect Cable ..............................................................................1-19

OM3 and OM4 (50/125 

μ

m) multimode SC cable  

 

assemblies................................................................................................1-16

OM3 and OM4 (50/125 

μ

m) multimode ST cable  

 

assemblies................................................................................................1-16

OM3 and OM4 (50 

μ

m) and OM2 (50/125 

μ

m) Multimode  

 

LC Test Kits ........................................................................................... 1-139

OM3 and OM4 (50 

μ

m) and OM2 (50/125 

μ

m) Multimode  

 

Replacement Components for LC Test Kits ....................... 1-139

OM3 and OM4 Multimode Epoxy/Polish Connectors ...............1-39
OM3 and RMG OM4 (50/125 

µ

m) Multimode Snap-in  

 

Adapter Plates ......................................................................................1-47

OM3 High Fiber Count Trunks .........................................................1-4, 1-5
OM3 MPO Microcable Trunk Assemblies ............................................1-3
OM4 High Fiber Count Trunks .........................................................1-4, 1-5
OM4 MPO Microcable Trunk Assemblies ............................................1-3
OMX Cable Clamps .................................................................................... 1-102
OMX Splice Cabinet .................................................................................... 1-101

Sc9_Index_v1.indd   11

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Product Name

9-12

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

OMX Splice Wheel ...................................................................................... 1-102 
Optical Distribution Frame ...................................................................... 1-72
Optical Fiber Cables ....................................................................................1-113
Optical Fiber Cable Technical Information ............................ 1-31–1-33
Optical Fiber Cable Temperature Ranges.........................................1-31
Optical LAN Solution ................................................................................1-106
OPTIPOP C Card Optical Connector Cleaner ...............................1-135
OPTIPOP R Reel Optical Connector Cleaner ............................... 1-134
OS2 Singlemode Optical Fiber Interconnect Cable .........1-21, 1-24
Outback 520 Outdoor Series, Outdoor Category 5e UTP  
 

Cable ........................................................................................................ 3-34

Outback 620 Series, Outdoor Category 6 UTP Cable ..............3-18
Outback 640 Series, Outdoor Category 6A UTP Cable ........... 3-5
Outlets  .................................................................................................................4-3

P

Paired Terminal Technology ..................................................................... 8-3
Palm Grip Hand Tool Kits ....................................................................... 3-123
Palm Grip Tool ................................................................................................3-117
Panel Configurations ...................................................................................1-70
Paper Labels ......................................................................................3-113–3-114
Patch Cords for Feed-Thru (FT) ..........................................................3-92
Patch Cords for Feed-Thru (FT) Blocks .......................................... 3-93
Patch Cords for Ultim8 Blocks ................................................. 3-28–3-29
Patch Panel Rear Termination Options ............................................8-25
Pistol Grip Tool for AMP-BARREL Edge Connectors ............. 3-122
Polarity for MPO to MT-RJ, LC, SC, ST, or FC ..................................1-10
Polishing Bushings .......................................................................................1-132
Polishing Films ..............................................................................................1-130
Portable “Butterfly” Hand Tool (MI-1) for CHAMP 25-Pair  
 

Connectors .......................................................................................... 3-123

Power Cordage..............................................................................................3-72
Power over Ethernet Products .............................................................3-74
Pre-configured Termination/Splice Panels ......................................1-99
Pre-Manufactured, Modular Power System ......................................7-3
PRO-CRIMPER III Fiber Die Sets ..........................................................1-133
PRO-CRIMPER III Fiber Optic Hand Tool ........................................1-133
PRO-CRIMPER III Hand Tool ................................................................. 3-118
Professional Fiber Connector Inspection/Cleaning Kits ........ 1-136
Pro-Installer’s Modular Plug Hand Tool ..........................................3-120
Pro-Installer’s Modular Plug Hand Tool Kits and  
 

Accessories ...........................................................................................3-121

Pro-Installer Twisted Pair Tool Kit ....................................................... 3-116

Q

Q-Frame  ............................................................................................................5-13
Q-Frame 19-inch rack kit ...........................................................................5-14
Q2000 Series Network Panels ..............................................................5-15
Q3000 ................................................................................................................1-53
Q3000 Blades ................................................................................................1-54
Q3000 SAM Blades ...................................................................................1-104
Q4000 Series ....................................................................................................5-7
QBCB-HR .................................................................................................1-53, 5-7

QCC-4 Chassis Controller .........................................................................5-10
QPC-2 Panel Controller Compatible with Q2000 Network  
 

Panels ........................................................................................................5-15

QPWRS-USA ...................................................................................................5-10
QSFP/QSFP+ ................................................................................................. 3-68
QSFP/QSFP+ High Speed Copper Cable Assemblies ............ 3-69
Quareo  ..................................................................................................................5-7
Quareo Cross Connect Frame................................................................5-13
Quareo Managed Array Cables .............................................................. 5-11
Quareo Managed Fiber Cables ..............................................................5-10
Quareo Managed Trunk .............................................................................. 5-11
Quareo Series Network Chassis ..............................................................5-7
Quick-Fit Fiber Modules .......................................................................... 3-66

R

Rack Mount Cable Trough ....................................................................  6-24
Rack Mount Media Converter Chassis System .............................3-78
Rack Mount Mounting Frames ...........................................................  6-34
Rapid Fiber Distribution Hub (iFDH) ................................................1-108
Rapid Fiber Distribution Terminal ....................................................... 1-110
Replacement Components for Singlemode LC Test Kits ........1-141
Residential Products ......................................................................................7-3
RJ45 Coupler Panel ....................................................................................3-79
RJ45 Dust Cover...........................................................................................3-87
RJ45 SECURE Category 6 Modular Plugs .......................................2-18
RJ45 SECURE Category 6 Patch Cable Assemblies .................2-19
RJ45 SECURE SL Series Category 6 Modular Jacks ................. 2-17
RMG  .....................................................................................................................1-55
RMG Empty Panels ......................................................................................1-55
RMG Maximum Capacity by Adapter Style and Chassis  
 

Height .........................................................................................................1-61

RMG Plug-and-Play Cassettes ...............................................................1-59
RMG Pre-configured Panels with Adapters only or with  
 

Pigtails .......................................................................................................1-58

RMG Product Overview ............................................................................ 1-60
RMG Standard Adaptor Packs ...............................................................1-56
Rod Mount Bracket Spacer..................................................................  6-33

S

SAM Far End Enclosure ...........................................................................1-103
SAM Hydra ......................................................................................................1-105
SAM MPO Adaptor Plates ......................................................................1-104
SAM MPO Cable Assemblies ................................................................1-105
SAM MPO Linecard Kits ..........................................................................1-105
SAM System Miscellaneous Components ......................................1-104
SC Connector Cleaner (In Bulkhead Cleaner) ............................. 1-136
SC style FTB's with Factory Terminated Stubs  
 

144-position Block ..............................................................................1-78

SECURE Copper Connectivity ............................................................... 2-17
SECURE Fiber Connectivity ..................................................................... 2-3
SECURE Network Solutions .............................................................................
 

LC Duplex Clips ..................................................................................... 2-4

 

LC SECURE Duplex Hybrid Cable Assemblies ..........2-8, 2-10

Sc9_Index_v1.indd   12

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Product Name

9-13

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

LC SECURE Epoxy/Polish Simplex Connectors .................. 2-4

 

LC SECURE LightCrimp PLUS Simplex Connectors  

 

 

(No expoxy/No polish) ........................................................... 2-3

 

LC SECURE SL Series Duplex Couplers .................................. 2-5

 

LC SECURE Snap-In Adapter Plates ......................................... 2-6

 

MPO SECURE Optical Fiber Cassettes ...................................2-14

 

MPO SECURE to Non-SECURE LC Optical Fiber  

 

 

Cassettes .........................................................................................2-7

 

MPO SECURE Trunk Cable Assemblies, Plenum  

 

 

(OFNP) ...........................................................................................2-15

 

MT-RJ SECURE Hybrid Cable Assemblies ............................. 2-11

 

MT-RJ SECURE Outlet Jacks ............................................. 2-12, 2-13

 

RJ45 SECURE Category 6 Modular Plugs ............................2-18

 

RJ45 SECURE Category 6 Patch Cable Assemblies .......2-19

 

RJ45 SECURE SL Series Category 6 Modular Jacks ....... 2-17

 

SECURE Copper Connectivity ..................................................... 2-17

 

SECURE Fiber Connectivity ........................................................... 2-3

 

Security Key Jack ............................................................................. 2-20

 

Security Key Patch Cord .................................................................2-21

 

Security Key Plug .............................................................................. 2-20

Security Consolidation Point for Raised Floors .......................... 3-95
Security Key Jack ........................................................................................ 2-20
Security Key Patch Cord ................................................................ 1-117, 2-21
Security Key Plug .............................................................................1-116, 2-20
SFP+  ................................................................................................................... 3-68
SFP+ High Speed Copper Cable Assemblies............................... 3-69
Side-Mount Label Holder .........................................................................3-113
Sigma-Link ......................................................................................................3-60
Sigma-Link Cat6A F/UTP Cable Assemblies ................................3-62
Sigma-Link Cat6 UTP Cable Assemblies..........................................3-61
Sigma-Link Patch Panel ............................................................................3-62
Simplex Drop Cables ...................................................................................1-112
Singlemode (1310/1550 nm) Optical Fiber Cable  
 

Performance Specifications ......................................................... 1-30

Singlemode Adapters .................................................................................1-52
Singlemode Couplers ..................................................................................1-52
Singlemode Epoxy/Polish Connectors ..............................................1-42
Singlemode High Fiber Count Trunks ..........................................1-4, 1-5
Singlemode LC cable assemblies ..........................................................1-16
Singlemode LC Test Kits............................................................................1-141
Singlemode LightCrimp PLUS Connectors  
 

(No epoxy/No polish) .......................................................................1-37

Singlemode Microcable Trunk Assemblies .........................................1-3
Singlemode MTRJ cable assemblies....................................................1-16
Singlemode Reduced Bend Radius Multifiber Cable  
 

Assemblies ..............................................................................................1-114

Singlemode SC cable assemblies ..........................................................1-16
Singlemode Snap-in Adapter Plates .................................................. 1-50
Singlemode ST cable assemblies ..........................................................1-16
Sliding Adapter Packs .....................................................................1-72, 1-84
SL Series Category 3 Modular Jacks ................................................ 3-86
SL Series Category 5e Modular Jacks .............................................3-40
SL Series Faceplates............................................................1-120, 4-5–4-24

SL Series Furniture Outlets .........................................................4-18–4-24
SL Series Modular Category 6 Jack Accessories ........................3-24
SL Series Modular Coupler .......................................................................3-41
SL Series Modular Jack Strain Relief .................................................3-87
SL Series Modular Jack Termination Accessories.......................3-115
SL Series Modular Jack Termination Tool .......................................3-115
SL Series Modules ............................................................................. 4-5–4-24
SL Series Multimedia Inserts ......................................................4-21–4-24
SL Series Tool ...................................................................................................8-4
Smart Ethernet Switches .........................................................................3-74
SNMP Managed Ethernet Switches ...................................................3-74
Solid Copper Bonding Connectors .................................................  6-25
Stainless Steel Faceplates ......................................................................... 4-7
Stainless Steel Faceplates from Semtron ..............................4-7–4-24
Standard Cross-Connect Patch Cord Lengths ..............................1-89
Standard FLEX-MODE Modular Furniture Faceplate  
 

Kits   ............................................................................................... 4-17–4-24

Standard Labels for Outlets .................................................................3-104
Standard Panels .............................................................................................. 3-8
Stationary, Ventilated Shelf ...................................................................  6-19
Storage Area Management ....................................................................1-103
STP Quick-Fit Modules ............................................................................. 3-65
Stranded Copper Bonding Connectors ........................................  6-25
Strip Card Kit ..................................................................................................1-132
Subfloor Panel Holder Kit ........................................................................3-67
Supplementary Solutions ..................................................................................
 

Broadcast Products .............................................................................7-3

 

Distributed Antenna Systems ........................................................7-3

 

Pre-Manufactured, Modular Power System ............................7-3

 

Residential Products ...........................................................................7-3

 

Undercarpet Cabling ...........................................................................7-3

Surface Boxes..................................................................................................4-13
Surface Mount Accessories ......................................................................4-11
Surface Mount Module ...............................................................................4-12
Surface Mount Outlet...................................................................................4-11
Switches  ...........................................................................................................3-73

T

Technical Reference ..............................................................................................
 

25-Pair Cable Color-Coding ..........................................................8-17

 

Backbone Cabling ...............................................................................8-11

 

Cable Installation .................................................................................8-15

 

Category 5e, 6 and 6A Cabling ..................................................8-23

 

Copper Design Technology ............................................................ 8-3

 

Cycle Life ..................................................................................................8-4

 

Horizontal Cabling ..............................................................................8-12

 

How AirES Cable Technology Lowers Temperatures While  

 

 

Increasing Uptime ..................................................................... 8-5

 

Jack Pin-Outs ........................................................................................8-16

 

Paired Terminal Technology ........................................................... 8-3

 

Patch Panel Rear Termination Options ..................................8-25

 

SL Series Tool .........................................................................................8-4

Termination Block Mounting Hardware .........................................  6-26

Sc9_Index_v1.indd   13

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Product Name

9-14

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

TFP Empty Chassis ......................................................................................1-63
TFP Fiber Panels .......................................................................................... 1-107
TFP MPO Pack ................................................................................................. 1-71
TFP Plug-and-Play Cassettes ..................................................... 1-68–1-69
TFP Pre-configured Termination/Splice Fiber Panels ...............1-66
TFP Product Overview ...............................................................................1-67
TFP Series Custom Adapter Packs .....................................................1-65
TFP Series Rack Mount Fiber Panels ..................................................1-67
TFP Series Standard Adapter Packs ................................................. 1-64
Tooling Category 6 Modular Plugs .................................................... 3-119
Tool Kit Compatibility Chart .................................................................. 1-124 
TRA-CON Epoxy...........................................................................................1-128 
TrueNet Labeling Software and Labeling Sheets ...................... 1-138
Trunks, High Fiber Plug-and-Play ........................................................... 1-4
Twisted Pair Cable Packaging Reference ...........................3-20, 3-36
Twisted Pair Testing Tools ..................................................................... 3-124
Type 85 Back Mount Frames ...............................................................  6-31
Type 85 Rod Mount Brackets .............................................................  6-32
Type 105 Back Mount Frames .............................................................  6-31
Type 105 Back Mount Frames with Ground Lug ......................  6-32
Type 105 Hinged Label Holder ..............................................................3-112
Type 105 Label Holder ...............................................................................3-112
Type 105 Label Strip ...................................................................................3-112
Type 105 Rod Mount Brackets ...........................................................  6-33

U

UCP Drawer Style Enclosure ................................................................. 3-64
UCP Patch Panel .......................................................................................... 3-64
Ultim8 1-Pair Patch Cords ...........................................................3-29–3-30
Ultim8 2-Pair Patch Cords ..........................................................3-29–3-30
Undercarpet Cabling .....................................................................................7-3
Universal Connectivity Platform (UCP)........................................... 3-63
Universal Labels ..........................................................................................3-105
Universal Mounting System (UMS) ..................................................  6-27
Universal Mounting System (UMS) Backboards ......................  6-29
Universal Mounting System (UMS) Cable ....................................  6-28
Universal Mounting System (UMS) High Volume Cable  
 

Managers ............................................................................................   6-30

Universal Mounting System (UMS) Wire Managers ................  6-28
UTP Quick-Fit Modules ............................................................................ 3-65

V

Velcro Cable Ties ............................................................................. 1-137, 3-101
Vertical Duct Systems...............................................................................   6-11
Vertical Finger Duct Panels .................................................................  6-22
Vertical Panel Mounting Brackets .......................................................3-67
Video Distribution Hub .............................................................................3-72
Video Distribution System (VDS) .........................................................3-71

W

Wall Boxes ..........................................................................................................1-111
Wall/Furniture Mounting Bracket ..................................................... 3-100
Wall Mount Mounting Frames ............................................................  6-34

WMG ................................................................................................................... 1-90
WMG-2000-00B .......................................................................................... 1-90
WMG-4000-00B ......................................................................................... 1-90
WMG-8000-00B .......................................................................................... 1-90
WMG Standard Adapter Packs ..............................................................1-91
Work Area Outlets .................................................................................................
 

12-Port Universal Surface Mount Outlet .................................4-13

 

Accessories .............................................................................................4-3

 

Adapters for Furniture Faceplates ..........................................4-20

 

Angled Faceplates...............................................................................4-6

 

Desktop Monuments .........................................................................4-16
Extenders for Furniture Faceplates ........................................4-20

 

Faceplates ................................................................................................4-3

 

Faceplates for Herman Miller Furniture ..................................4-19

 

Faceplates for Mounting Straps ...................................................4-8

 

Faceplates for WIREMOLD Raceways ................................... 4-14

 

FLEX-MODE Modular Furniture Faceplate  

 

 

Accessories ................................................................................4-20

 

HIDEAWAY Multimedia Outlets.................................................. 4-10

 

HIDEOUT Outlets .................................................................................4-9

 

Modular Jack Boxes .......................................................................... 4-14

 

Mounting Straps ...................................................................................4-8

 

MT-RJ, LC Adapters and SL ........................................................ 4-23

 

Multimedia Modules for Work Area Outlets ....................... 4-24

 

Outlets .......................................................................................................4-3

 

SL Series Faceplates ..........................................................................4-5

 

SL Series Furniture Outlets............................................................4-18

 

SL Series Module ..................................................................................4-5

 

SL Series Multimedia Inserts .........................................................4-21

 

Standard FLEX-MODE Modular Furniture Faceplate  

Kits ....................................................................................................4-17

Surface Mount Accessories ............................................................4-11
Surface Mount Module .....................................................................4-12

 

Surface Mount Outlet ........................................................................4-11

 

Wall Phone Faceplate ........................................................................4-6

 

WIREMOLD 2A Inserts .....................................................................4-15

X

x-1933882 ....................................................................................................... 3-128
x-1933885 ....................................................................................................... 3-128

Sc9_Index_v1.indd   14

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-15

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

0

0-1671196-1 .......................................................3-66
0-1671196-3 ......................................................3-66
0-1671202-1 ......................................................3-66
0-1671202-3 ....................................................3-66
0-2153115-1 .......................................................3-54

1

1-1116406-1 ...........................................................4-5
1-1116406-3 ..........................................................4-5
1-1116407-1 ...........................................................4-5
1-1116407-3 ..........................................................4-5
1-1116408-1 ...........................................................4-5
1-1116408-3 ..........................................................4-5
1-1116409-1 ...........................................................4-5
1-1116409-3 ..........................................................4-5
1-1116410-1 ............................................................4-5
1-1116410-3 ...........................................................4-5
1-1116412-1 .......................................................... 4-22
1-1116412-3 ......................................................... 4-22
1-1116616-1 .............................................................4-8
1-1116618-1 .............................................................4-8
1-1116697-1 .......................................................... 4-14
1-1116698-1 ......................................................... 4-14
1-1116733-0 .......................................................3-80
1-1116733-5 ........................................................3-80
1-1116734-0 .......................................................3-80
1-1116734-5 .......................................................3-80
1-1339118-1 ............................................................4-5
1-1339118-3 ..........................................................4-5
1-1339120-1 ..........................................................4-8
1-1339123-3 ...................................................... 4-22
1-1374416-0 ......................................................4-23
1-1374416-1 ........................................................4-23
1-1375055-0..................................................... 3-23
1-1375055-1 ...................................................... 3-23
1-1375055-3 ..................................................... 3-23
1-1375092-0 ...................................................3-102
1-1375092-1 .....................................................3-102
1-1375155-1 ...........................................................4-6
1-1375155-3 ..........................................................4-6
1-1375187-0 ...................................................... 3-23
1-1375187-1 ........................................................ 3-23
1-1375187-3 ....................................................... 3-23
1-1375190-0 ....................................................... 3-41
1-1375190-1 ........................................................ 3-41
1-1375190-3 ....................................................... 3-41
1-1375191-0 ........................................................ 3-41
1-1375191-1 .......................................................... 3-41
1-1375191-3 ......................................................... 3-41
1-1375192-3 .......................................................3-86
1-1375306-1 .........................................................4-5

1-1375306-3 ........................................................4-5
1-1375361-3 ....................................................... 4-22
1-1375362-3 ..................................................... 4-22
1-1375363-3 ..................................................... 4-22
1-1479079-3 ........................................................4-5
1-1479152-1 ...........................................................4-6
1-1479152-3 .........................................................4-6
1-1479159-1...........................................................4-8
1-1479160-1 ..........................................................4-8
1-1479181-3 ....................................................... 4-22
1-1479190-3 ...................................................... 4-22
1-1479191-3 ....................................................... 4-22
1-1479230-3 ..................................................... 4-22
1-1479231-3 ...................................................... 4-22
1-1479232-3 ..................................................... 4-22
1-1479358-1 ....................................................... 4-13
1-1479358-3 ...................................................... 4-13
1-1479486-1 .........................................................4-5
1-1479486-3........................................................4-5
1-1479504-1 .........................................................4-8
1-1479625-1 .........................................................4-8
1-1479784-1 .........................................................4-8
1-1479815-1 .........................................................4-10
1-1479946-1 .......................................................4-10
1-1499836-1 ...................................................... 4-22
1-1499836-3 .................................................... 4-22
1-1499841-0 .......................................................2-19
1-1499841-2 ........................................................2-19
1-1499841-4 .......................................................2-19
1-1499841-6 .......................................................2-19
1-1499842-0 ......................................................2-19
1-1499842-2 ......................................................2-19
1-1499842-4 ......................................................2-19
1-1499842-6 ......................................................2-19
1-1499843-0 ......................................................2-19
1-1499843-2 ......................................................2-19
1-1499843-4 ......................................................2-19
1-1499843-6 ......................................................2-19
1-1499844-0......................................................2-19
1-1499844-2 ......................................................2-19
1-1499844-4 ......................................................2-19
1-1499844-6 ......................................................2-19
1-1499845-0 ......................................................2-19
1-1499845-2 ......................................................2-19
1-1499845-4 ......................................................2-19
1-1499845-6 ......................................................2-19
1-1499846-0 ......................................................2-19
1-1499846-2 ......................................................2-19
1-1499846-4 ......................................................2-19
1-1499846-6 ......................................................2-19
1-1499848-0 ......................................................2-19
1-1499848-2 ......................................................2-19
1-1499848-4 ......................................................2-19

1-1499848-6 ......................................................2-19
1-1499849-0 ......................................................2-19
1-1499849-2 ......................................................2-19
1-1499849-4 ......................................................2-19
1-1499849-6 ......................................................2-19
1-1499850-0 ......................................................2-19
1-1499850-2 ......................................................2-19
1-1499850-4 ......................................................2-19
1-1499850-6 ......................................................2-19
1-1499851-0 .......................................................2-19
1-1499851-2 ........................................................2-19
1-1499851-4 .......................................................2-19
1-1499851-6 ........................................................2-19
1-1499852-0 ......................................................2-19
1-1499852-2 .......................................................2-19
1-1499852-4 ......................................................2-19
1-1499852-6 ......................................................2-19
1-1499853-0 ......................................................2-19
1-1499853-2 .......................................................2-19
1-1499853-4 ......................................................2-19
1-1499853-6 ......................................................2-19
1-1499855-1 ...................................................... 4-22
1-1499855-3..................................................... 4-22
1-1499925-3 ..................................................... 3-23
1-5502776-1 .......................................................1-52
1-1553307-2 .....................................................1-142
1-1553308-2 .....................................................1-142
1-1553311-2 ........................................................1-142
1-1553312-2.......................................................1-142
1-1553315-2 ......................................................1-142
1-1553316-2 ......................................................1-142
1-1553406-1 ....................................................... 1-20
1-1553406-2 ..................................................... 1-20
1-1553407-1 ....................................................... 1-20
1-1553407-2 ...................................................... 1-20
1-1553408-1 ....................................................... 1-20
1-1553408-2 ..................................................... 1-20
1-1553409-1 ....................................................... 1-20
1-1553409-2 ..................................................... 1-20
1-1553410-1 ........................................................ 1-20
1-1553410-2 ....................................................... 1-20
1-1553411-1 .......................................................... 1-20
1-1553411-2......................................................... 1-20
1-1553412-1 ......................................................... 1-20
1-1553412-2 ....................................................... 1-20
1-1553413-1 ......................................................... 1-20
1-1553413-2 ....................................................... 1-20
1-1553414-1 ........................................................ 1-20
1-1553414-2 ....................................................... 1-20
1-1553415-1 ......................................................... 1-20
1-1553415-2 ....................................................... 1-20
1-1553416-1 ........................................................ 1-20
1-1553416-2 ...........................................1-20, 1-142

Sc9_Index_v1.indd   15

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-16

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

1-1553417-1 ......................................................... 1-20
1-1553417-2............................................1-20, 1-142
1-1553418-1 ........................................................ 1-20
1-1553418-2 ...........................................1-20, 1-142
1-1553419-1 ........................................................ 1-20
1-1553419-2 ...........................................1-20, 1-142
1-1553420-2 .....................................................1-142
1-1553534-0 ....................................................1-105
1-1553640-0 ....................................................1-105
1-1671215-1 ......................................................... 3-62
1-1671548-1 .......................................................3-64
1-1671549-1 ....................................................... 3-67
1-1671594-1 .......................................... 3-54, 3-64
1-1671603-1 ....................................................... 3-67
1-1777127-0 .........................................................2-6
1-1777265-0 ........................................................2-6
1-1777266-0 ........................................................2-6
1-1828078-0 .......................................................2-4
1-1828079-0 .......................................................2-4
1-1828856-0 ....................................................... 2-3
1-1828860-0 ....................................................... 2-3
1-1828861-0 .........................................................2-4
1-1828862-0 .......................................................2-4
1-1871456-2 ......................................................2-20
1-1918777-0 ........................................................2-14
1-1918777-1 ..........................................................2-14
1-1918778-0 ........................................................2-14
1-1918778-1 ..........................................................2-14
1-1918779-0 ........................................................2-14
1-1918779-1 ..........................................................2-14
1-1918780-0 .......................................................2-14
1-1918780-1 .........................................................2-14
1-1918781-0 .........................................................2-14
1-1918781-1 ...........................................................2-14
1-1918782-0 ........................................................2-14
1-1918782-1 ..........................................................2-14
1-1918783-0 ........................................................2-14
1-1918783-1..........................................................2-14
1-1918784-0 .......................................................2-14
1-1918784-1 .........................................................2-14
1-1918785-0 ......................................................... 2-7
1-1918785-1........................................................... 2-7
1-1918786-0......................................................... 2-7
1-1918786-1 .......................................................... 2-7
1-1933096-3 .................................................... 4-22
1-1933172-1 ......................................................... 4-14
1-1933192-3 ...................................................... 4-22
1-1933193-3 ...................................................... 4-22
1-1933194-3 ...................................................... 4-22
1-1933285-0 .......................................................2-5
1-1933286-1 ...................................................... 4-22
1-1933286-2 ..................................................... 4-22
1-1933422-0 .......................................................2-5

1-1933455-3 ...................................................... 3-41
1-1933582-3 ..................................................... 4-22
1-1933659-3 ..................................................... 4-22
1-1933661-3 ...................................................... 4-22
1-1933668-1 ........................................................4-12
1-1933668-3 .......................................................4-12
1-1933671-1 ..........................................................4-12
1-1933671-3 ........................................................4-12
1-1933674-1.........................................................4-12
1-1933674-3 .......................................................4-12
1-1933686-1 .........................................................4-5
1-1933686-3 ........................................................4-5
1-1938056-0 ......................................................2-14
1-1938056-1 ........................................................2-14
1-1938965-0 ......................................................2-14
1-1938965-1 ........................................................2-14
1-1938966-0 ....................................................... 2-7
1-1938966-1 ......................................................... 2-7
1-1938967-0 ....................................................... 2-7
1-1938967-1 ......................................................... 2-7
1-1938996-0 ......................................................2-14
1-1938996-1 ........................................................2-14
1-1985713-0 ......................................................... 2-7
1-1985713-1 ........................................................... 2-7
1-1985797-0 ........................................................ 2-7
1-1985797-1 .......................................................... 2-7
1-1985798-0 ....................................................... 2-7
1-1985798-1 ......................................................... 2-7
1-1985799-0 ....................................................... 2-7
1-1985799-1 ......................................................... 2-7
1-1985959-0 ....................................................... 2-3
1-1985960-0 ....................................................... 2-3
1-1985961-0 ........................................................ 2-3
1-2111179-0 ...............................................1-117, 2-21
1-2111179-2 ................................................1-117, 2-21
1-2111179-4................................................1-117, 2-21
1-2111179-6 ................................................1-117, 2-21
1-2111179-8 ................................................1-117, 2-21
1-2111190-0 ...............................................1-117, 2-21
1-2111190-2 ...............................................1-117, 2-21
1-2111190-4 ...............................................1-117, 2-21
1-2111190-6 ...............................................1-117, 2-21
1-2111190-8 ...............................................1-117, 2-21
1-2111225-0 ..............................................1-117, 2-21
1-2111225-2 ...............................................1-117, 2-21
1-2111225-4 ..............................................1-117, 2-21
1-2111225-6...............................................1-117, 2-21
1-2111225-8 ...............................................1-117, 2-21
1-2111236-0 ..............................................1-117, 2-21
1-2111236-2...............................................1-117, 2-21
1-2111236-4 ..............................................1-117, 2-21
1-2111236-6 ..............................................1-117, 2-21
1-2111236-8 ..............................................1-117, 2-21

1-2111408-2 .......................................................4-23
1-2111408-3 .......................................................4-23
1-2111501-0 .........................................................3-72
1-2111505-0 ........................................................3-72
1-2111510-0 .........................................................3-72
1-2111515-0 .........................................................3-72
1-2111550-3 ....................................................... 4-22
1-2111615-3 ......................................................... 4-22
1-231666-0 ....................................................... 3-121
1-231666-1 ......................................................... 3-121
1-231666-2 ....................................................... 3-121
1-231666-3 ....................................................... 3-121
1-231666-4 ....................................................... 3-121
1-406185-1 ...........................................................4-6
1-406185-3 ..........................................................4-6
1-558198-0 ......................................................3-102
1-558198-1 ........................................................3-102
1-558199-0 ......................................................3-102
1-558199-1 ........................................................3-102
1-558251-1 .......................................................... 4-13
1-558251-3 ......................................................... 4-13
1-558821-0 ......................................................3-102
1-558821-1 ........................................................3-102
1-569499-1 ........................................................ 4-13
1-569499-3 ....................................................... 4-13
1-569523-0 ......................................................3-45
1-569524-0 ......................................................3-45
1-569526-0 ......................................................3-45
1-569527-0 ......................................................3-45
1-569528-0 ......................................................3-45
1-569669-0 .....................................................3-45
1-569685-0 .....................................................3-45
1-569875-0 ......................................................3-43
1-603227-0 ..........................................1-137, 3-101
1-603227-9 ..........................................1-137, 3-101
1-604751-0 ...........................................1-137, 3-101
1-604751-9 ...........................................1-137, 3-101
1-604771-0 ...........................................1-137, 3-101
1-604771-9 ...........................................1-137, 3-101
1-604772-0 ..........................................1-137, 3-101
1-604772-9 ..........................................1-137, 3-101
1-6278807-0 .....................................................2-13
1-6278808-0 .....................................................2-13
1-6278810-0 ......................................................2-13
1-6278811-0 ........................................................2-13
1-6588878-0 .....................................................2-13
1-6588879-0 .....................................................2-13
1-6693949-0 ....................................................2-13
1-6693951-0 ......................................................2-13
1-6754252-0 .....................................................2-13
1-6754285-0 .....................................................2-14
1-6754285-1 .......................................................2-14
1-6754286-0 .....................................................2-14

Sc9_Index_v1.indd   16

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-17

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

1-6754286-1 .......................................................2-14
1-6754287-0 .....................................................2-14
1-6754287-1 .......................................................2-14
1-6754288-0 .....................................................2-14
1-6754288-1 .......................................................2-14
1-6828819-0 ......................................................2-14
1-6828819-1 ........................................................2-14
1-790163-0 .......................................................3-119
1-853400-0 ....................................................3-120
1-853400-4 ....................................................3-120
11-1479079-1 ........................................................4-5
1116044-2 ........................................................ 3-106
1116098-1 ..............................................................4-11
1116111-1 ...................................................................4-11
1116360-3 ...............................................1-122, 4-16
1116406-1 ..............................................................4-5
1116406-2 .............................................................4-5
1116406-4 ............................................................4-5
1116407-1 ...............................................................4-5
1116407-2 .............................................................4-5
1116407-4 .............................................................4-5
1116408-1 ..............................................................4-5
1116408-2 .............................................................4-5
1116408-4 ............................................................4-5
1116409-1 ..............................................................4-5
1116409-2 .............................................................4-5
1116409-4 ............................................................4-5
1116410-1 ................................................................4-5
1116410-2 ..............................................................4-5
1116410-4 ..............................................................4-5
1116412-1 ..................................................1-119, 4-22
1116412-2 ............................................................ 4-22
1116412-3 ............................................................ 4-22
1116412-4 ........................................................... 4-22
1116535 ............................................................. 3-108
1116571-1 .............................................................3-118
1116580-1 .............................................................4-17
1116580-2 ............................................................4-17
1116580-4 ............................................................4-17
1116616-1 ................................................................4-8
1116616-2 ...............................................................4-8
1116616-3 ...............................................................4-8
1116616-4 ..............................................................4-8
1116618-1 ................................................................4-8
1116618-2 ...............................................................4-8
1116618-3 ...............................................................4-8
1116618-4 ..............................................................4-8
1116697 ............................................................. 3-108
1116697-1 ............................................................. 4-14
1116697-2 ............................................................ 4-14
1116697-3 ............................................................ 4-14
1116697-4 ........................................................... 4-14
1116698 ............................................................. 3-108

1116698-1 ............................................................. 4-14
1116698-2 ........................................................... 4-14
1116698-3 ........................................................... 4-14
1116698-4 ........................................................... 4-14
1116732-1 ............................................................3-80
1116733-5 ...........................................................3-80
1116733-7 ...........................................................3-80
1116734-5 ...........................................................3-80
1116734-7 ...........................................................3-80
1206146-1 ........................................................3-100
122533-1............................................................3-122
1278017-1 .............................................................1-52
1278023-1 .........................................................1-126
1278118-4 ...............................................1-124, 1-125
1278118-5 ...............................................1-124, 1-125
1278346-1 .............................................1-124, 1-126
1278346-2 ............................................1-124, 1-126
1339118 ............................................................. 3-108
1339118-1 ..................................................1-120, 4-5
1339118-2..............................................................4-5
1339118-4 .............................................................4-5
1339119-1 ............................................................1-120
1339120-1 .............................................................4-8
1339120-2 ............................................................4-8
1339120-3 ............................................................4-8
1339120-4 ............................................................4-8
1339123-1 ........................................................... 4-22
1339123-2 ......................................................... 4-22
1374416-1 ...........................................................4-23
1374416-2 ..........................................................4-23
1374416-3..........................................................4-23
1374416-4 .........................................................4-23
1374416-5..........................................................4-23
1374416-6 .........................................................4-23
1374416-7 ..........................................................4-23
1374416-8 .........................................................4-23
1374416-9 .........................................................4-23
1374484-1 .........................................................1-130
1375005 .......................................................... 3-108
1375005-1 .......................................................... 4-18
1375005-2 ......................................................... 4-18
1375005-3 ......................................................... 4-18
1375005-4 ........................................................ 4-18
1375006 .......................................................... 3-108
1375006-1 .......................................................... 4-18
1375006-2 ......................................................... 4-18
1375006-3......................................................... 4-18
1375006-4 ........................................................ 4-18
1375013 ............................................................ 3-109
1375013-2 ......................................................... 3-22
1375014 ............................................................ 3-109
1375014-2 ............................................3-22, 3-126
1375015 ............................................................ 3-109

1375015-2 ............................................3-22, 3-126
1375016 ............................................................ 3-109
1375016-2 ......................................................... 3-22
1375049 .......................................................... 3-108
1375049-1 .......................................................... 4-14
1375049-4 ........................................................ 4-14
1375050 .......................................................... 3-108
1375050-1 .......................................................... 4-14
1375050-4 ........................................................ 4-14
1375055- ..........................................................3-126
1375055-1.......................................................... 3-23
1375055-2 ........................................................ 3-23
1375055-4 ........................................................ 3-23
1375055-5 ........................................................ 3-23
1375055-6 ........................................................ 3-23
1375055-7 ........................................................ 3-23
1375055-8 ........................................................ 3-23
1375055-9 ........................................................ 3-23
1375092-1 ........................................................3-102
1375092-2 .......................................................3-102
1375092-3 .......................................................3-102
1375092-4 .......................................................3-102
1375092-5 .......................................................3-102
1375092-6 .......................................................3-102
1375092-7 .......................................................3-102
1375092-8 .......................................................3-102
1375092-9 .......................................................3-102
1375093-1 ......................................................... 3-97
1375149-2.......................................................... 4-22
1375155 ............................................................ 3-108
1375155-1 .................................................. 1-119, 4-6
1375155-2 .............................................................4-6
1375155-4 .............................................................4-6
1375157-1 ............................................................ 3-87
1375158-1 .........................................................  6-22
1375158-2 ........................................................  6-22
1375159-1 .........................................................  6-22
1375159-2 ........................................................  6-22
1375160-1 .........................................................  6-22
1375160-2 .......................................................  6-22
1375161-1 ..........................................................  6-22
1375161-2 .........................................................  6-22
1375162 ............................................................  6-22
1375162-2 ........................................................  6-22
1375163-1 .........................................................  6-22
1375163-2 ........................................................  6-22
1375164-1 .........................................................  6-22
1375165-1 .........................................................  6-22
1375166-1 .........................................................  6-22
1375167-1 .........................................................  6-22
1375187- ............................................................3-126
1375187-1 ........................................................... 3-23
1375187-2 .......................................................... 3-23

Sc9_Index_v1.indd   17

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-18

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

1375187-4 .......................................................... 3-23
1375187-5 .......................................................... 3-23
1375187-6 .......................................................... 3-23
1375187-7 .......................................................... 3-23
1375187-8 .......................................................... 3-23
1375187-9 .......................................................... 3-23
1375188-1 ........................................................... 3-23
1375189-1 ............................................................ 3-41
1375190- ...........................................................3-125
1375190-1 ............................................................ 3-41
1375190-2 .......................................................... 3-41
1375190-4 .......................................................... 3-41
1375190-5 .......................................................... 3-41
1375190-6 .......................................................... 3-41
1375190-7 .......................................................... 3-41
1375190-8 .......................................................... 3-41
1375190-9 .......................................................... 3-41
1375191- .............................................................3-125
1375191-1 ............................................................. 3-41
1375191-2 ............................................................ 3-41
1375191-4 ............................................................ 3-41
1375191-5 ............................................................ 3-41
1375191-6 ............................................................ 3-41
1375191-7 ............................................................ 3-41
1375191-8 ............................................................ 3-41
1375191-9 ............................................................ 3-41
1375192-1 ...........................................................3-86
1375192-2 ..........................................................3-86
1375192-4..........................................................3-86
1375192-6 ..........................................................3-86
1375200-1 ......................................................... 3-87
1375253-2 .............................................1-137, 3-101
1375254-2.............................................1-137, 3-101
1375255-2 .............................................1-137, 3-101
1375255-6 .............................................1-137, 3-101
1375256-2 .............................................1-137, 3-101
1375257-1 ........................................................  6-22
1375258-1 ........................................................  6-22
1375259-1 ........................................................  6-22
1375260-1 .......................................................  6-22
1375289-1 .......................................................... 3-82
1375291-1 ........................................................... 3-82
1375292-1 .......................................................... 3-82
1375306-1 ............................................................4-5
1375306-2 ...........................................................4-5
1375306-4 ...........................................................4-5
1375307-1 ..........................................................3-116
1375308-1 .........................................................3-116
1375309-1 .........................................................3-116
1375310-1 ...........................................................3-116
1375317-1 ...........................................................3-118
1375345-1 .........................................................3-105
1375351-1 ......................................................... 3-106

1375352-1 ........................................................ 3-106
1375353-1 .......................................... 3-105, 3-106
1375354 .............................................................3-110
1375354-1 ............................................ 3-59, 3-107
1375354-2 .......................................... 3-59, 3-107
1375354-3 .......................................... 3-59, 3-107
1375355 .............................................................3-110
1375355-1 .........................................................3-107
1375356-1 ........................................................ 3-104
1375357-1 ........................................................ 3-104
1375358-1 .........................................................3-105
1375361-1 ........................................................... 4-22
1375362-1 .......................................................... 4-22
1375363-1 .......................................................... 4-22
1375367-1 .......................................................... 3-97
1375376-1 ..........................................................3-94
1435049-1 ........................................................  6-19
1435118-1 ............................................................1-140
1435119-1 ............................................................1-139
1435965-1 ......................................................... 3-58
1435971-1 ........................................................... 3-58
1457062-1 ...........................................................1-52
1457628-1..........................................................1-130
1457630-1 ......................................................... 1-132
1457630-2 ........................................................ 1-132
1479002 ............................... 3-108, 3-109, 3-110
1479002-1 ........................................................3-107
1479003 ............................... 3-108, 3-109, 3-110
1479003-1 ........................................................3-107
1479039-1 .........................................................3-96
1479040-1 ........................................................3-96
1479041-1 ..........................................................3-96
1479042-1 ......................................................... 3-95
1479079-1 ............................................................4-5
1479079-2 ...........................................................4-5
1479079-4 ...........................................................4-5
1479142-1 ........................................................... 3-97
1479144-1 ..........................................................3-94
1479152-1 ..............................................................4-6
1479153 ............................................................ 3-109
1479153-2.......................................................... 3-39
1479154 ............................................................ 3-109
1479154-2 ............................................3-39, 3-125
1479155 ............................................................ 3-109
1479155-2.............................................3-39, 3-125
1479156 ............................................................ 3-109
1479156-2 ......................................................... 3-39
1479158-1 ........................................................... 3-95
1479159-1 ..............................................................4-8
1479159-2 ............................................................4-8
1479159-3 ............................................................4-8
1479159-4 ............................................................4-8
1479160-1 .............................................................4-8

1479160-2 ............................................................4-8
1479160-3 ............................................................4-8
1479160-4............................................................4-8
1479181-1 ............................................................ 4-22
1479181-2 ........................................................... 4-22
1479190-1 .......................................................... 4-22
1479191-1 ............................................................ 4-22
1479206 .......................................................... 3-109
1479206-1 ......................................................... 3-39
1479208 .......................................................... 3-109
1479222-1 ........................................................  6-22
1479222-2.......................................................  6-22
1479223-1 ........................................................  6-22
1479224-1 ........................................................  6-22
1479225-1 ........................................................  6-22
1479225-2 ......................................................  6-22
1479230-1 ......................................................... 4-22
1479231-1 ........................................................... 4-22
1479232-1 .......................................................... 4-22
1479287-2 .........................................................4-24
1479297-1 .......................................................... 3-95
1479322-1 .......................................................... 3-97
1479326-1.......................................................... 3-95
1479358 ........................................................... 3-108
1479358-1........................................................... 4-13
1479358-2 ......................................................... 4-13
1479358-3 ......................................................... 4-13
1479358-4 ......................................................... 4-13
1479359-1 ......................................................... 3-95
1479360-1 ......................................................... 3-95
1479398-1 .......................................................... 4-13
1479402-1 .......................................................  6-23
1479449-1 ......................................................... 3-83
1479450-1 ......................................................... 3-83
1479451-1........................................................... 3-56
1479452-1 ......................................................... 3-56
1479459-1 ......................................................... 3-56
1479486 .......................................................... 3-108
1479486-1 ...............................................1-120, 4-5
1479486-2 ...........................................................4-5
1479486-4 ..........................................................4-5
1479504-1 ............................................................4-8
1479504-2 ...........................................................4-8
1479504-3...........................................................4-8
1479504-4 ..........................................................4-8
1479552-1 .......................................................... 3-23
1479582-1 ........................................................  6-23
1479625-1 ............................................................4-8
1479625-2 ...........................................................4-8
1479625-3 ...........................................................4-8
1479625-4 ...........................................................4-8
1479696-1 ......................................................... 3-97
1479698-1 ......................................................... 3-65

Sc9_Index_v1.indd   18

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-19

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

1479717-1 ............................................................ 3-41
1479732-1 ........................................................  6-23
1479733-1 ........................................................  6-23
1479784-1 ............................................................4-8
1479784-2 ...........................................................4-8
1479784-3 ...........................................................4-8
1479784-4 ...........................................................4-8
1479794-1 ...........................................................2-17
1479794-2 ..........................................................2-17
1479794-3 ..........................................................2-17
1479794-4 ..........................................................2-17
1479794-8 ..........................................................2-17
1479794-9 ..........................................................2-17
1479795-1 ............................................................2-17
1479795-2 ..........................................................2-17
1479795-3 ..........................................................2-17
1479795-4 ..........................................................2-17
1479795-8 ..........................................................2-17
1479795-9 ..........................................................2-17
1479815 ............................................................ 3-108
1479815-1 ............................................... 1-120, 4-10
1479815-2 ..........................................................4-10
1479815-3 ..........................................................4-10
1479815-4 ..........................................................4-10
1479860-1 .......................................................  6-25
1479946 .......................................................... 3-108
1479946-1 ............................................. 1-120, 4-10
1479946-2 .........................................................4-10
1479946-3 .........................................................4-10
1479946-4 ........................................................4-10
1479956-1 ......................................................... 3-95
1479992-1 ......................................................... 3-82
1479992-2 ........................................................ 3-82
1490490-1 ........................................................3-118
1490530-1 .......................................................3-124
1490531-1 .........................................................3-124
1490532-1 ........................................................3-124
1490533-1 ........................................................3-124
1499056-1 ........................................................3-98
1499056-2 .......................................................3-98
1499056-3 .......................................................3-98
1499056-4 .......................................................3-98
1499056-5 .......................................................3-98
1499056-6 .......................................................3-98
1499056-7 .......................................................3-98
1499056-8 .......................................................3-98
1499057-1 .........................................................3-98
1499057-2 ........................................................3-98
1499057-3 ........................................................3-98
1499057-4 .......................................................3-98
1499057-5 ........................................................3-98
1499057-6 .......................................................3-98
1499057-7 ........................................................3-98

1499057-8........................................................3-98
1499600 ......................................................... 3-109
1499600-2 ..........................................3-22, 3-126
1499601 ........................................................... 3-109
1499601-2 ...........................................3-22, 3-126
1499602 .......................................................... 3-109
1499602-2 ..........................................3-39, 3-125
1499603 .......................................................... 3-109
1499603-2 ..........................................3-39, 3-125
1499604 ......................................................... 3-109
1499605 .......................................................... 3-109
1499613-1 .......................................................... 3-83
1499614-1 .......................................................... 3-83
1499622-1 ......................................................... 3-82
1499623-1 ......................................................... 3-82
1499702-2 ...........................................................2-6
1499703-2 ...........................................................2-6
1499704-2 ..........................................................2-6
1499705-2 ...........................................................2-6
1499706-2 ..........................................................2-6
1499707-2 ...........................................................2-6
1499708-2...........................................................2-6
1499709-2 ..........................................................2-6
1499710-2 ............................................................2-6
1499711-2 .............................................................2-6
1499836-1 ......................................................... 4-22
1499836-2........................................................ 4-22
1499836-3 ....................................................... 4-22
1499836-4 ....................................................... 4-22
1499836-9 ........................................................ 1-119
1499841-2 ...........................................................2-19
1499841-3 ...........................................................2-19
1499841-4 ..........................................................2-19
1499841-5 ...........................................................2-19
1499841-6...........................................................2-19
1499841-7 ...........................................................2-19
1499841-8 ...........................................................2-19
1499841-9...........................................................2-19
1499842-2..........................................................2-19
1499842-3 .........................................................2-19
1499842-4 .........................................................2-19
1499842-5 .........................................................2-19
1499842-6 .........................................................2-19
1499842-7 ..........................................................2-19
1499842-8 .........................................................2-19
1499842-9 .........................................................2-19
1499843-2 .........................................................2-19
1499843-3 .........................................................2-19
1499843-4 .........................................................2-19
1499843-5 .........................................................2-19
1499843-6 .........................................................2-19
1499843-7 ..........................................................2-19
1499843-8 .........................................................2-19

1499843-9 .........................................................2-19
1499844-2 .........................................................2-19
1499844-3 .........................................................2-19
1499844-4 .........................................................2-19
1499844-5 .........................................................2-19
1499844-6 .........................................................2-19
1499844-7 .........................................................2-19
1499844-8 .........................................................2-19
1499844-9 .........................................................2-19
1499845-2 .........................................................2-19
1499845-3 .........................................................2-19
1499845-4 .........................................................2-19
1499845-5 .........................................................2-19
1499845-6 .........................................................2-19
1499845-7 ..........................................................2-19
1499845-8 .........................................................2-19
1499845-9 .........................................................2-19
1499846-2 .........................................................2-19
1499846-3 .........................................................2-19
1499846-4 .........................................................2-19
1499846-5 .........................................................2-19
1499846-6 .........................................................2-19
1499846-7 .........................................................2-19
1499846-8 .........................................................2-19
1499846-9 .........................................................2-19
1499848-2 .........................................................2-19
1499848-3 .........................................................2-19
1499848-4 .........................................................2-19
1499848-5 .........................................................2-19
1499848-6 .........................................................2-19
1499848-7..........................................................2-19
1499848-8 .........................................................2-19
1499848-9 .........................................................2-19
1499849-2 .........................................................2-19
1499849-3 .........................................................2-19
1499849-4 .........................................................2-19
1499849-5 .........................................................2-19
1499849-6 .........................................................2-19
1499849-7..........................................................2-19
1499849-8 .........................................................2-19
1499849-9 .........................................................2-19
1499850-2 .........................................................2-19
1499850-3 .........................................................2-19
1499850-4 .........................................................2-19
1499850-5 .........................................................2-19
1499850-6 .........................................................2-19
1499850-7 .........................................................2-19
1499850-8 .........................................................2-19
1499850-9 .........................................................2-19
1499851-2 ...........................................................2-19
1499851-3 ...........................................................2-19
1499851-4 ...........................................................2-19
1499851-5 ...........................................................2-19

Sc9_Index_v1.indd   19

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-20

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

1499851-6 ...........................................................2-19
1499851-7 ...........................................................2-19
1499851-8 ...........................................................2-19
1499851-9 ...........................................................2-19
1499852-2 ..........................................................2-19
1499852-3 ..........................................................2-19
1499852-4..........................................................2-19
1499852-5 ..........................................................2-19
1499852-6 ..........................................................2-19
1499852-7 ..........................................................2-19
1499852-8 ..........................................................2-19
1499852-9 ..........................................................2-19
1499853-2 ..........................................................2-19
1499853-3 ..........................................................2-19
1499853-4 .........................................................2-19
1499853-5 ..........................................................2-19
1499853-6 .........................................................2-19
1499853-7 ..........................................................2-19
1499853-8..........................................................2-19
1499853-9 .........................................................2-19
1499855-1 ..............................................1-119, 4-22
1499855-2 ........................................................ 4-22
1499855-3 ........................................................ 4-22
1499855-4 ....................................................... 4-22
1499925-2 ........................................................ 3-23
1499925-6........................................................ 3-23
1499925-7 ........................................................ 3-23
1499925-8 ........................................................ 3-23
1499925-9........................................................ 3-23
1553212-1 ........................................................... 1-124
1553527-1 ..........................................................1-105
1553527-2 .........................................................1-105
1553528-1 ..........................................................1-105
1553528-2 ........................................................1-105
1553529-1 ..........................................................1-105
1553529-2 ........................................................1-105
1553533-1 ..........................................................1-103
1553533-2 ........................................................1-103
1553534-1 .........................................................1-105
1553534-2 ........................................................1-105
1553534-3 ........................................................1-105
1553534-4 ........................................................1-105
1553534-5 ........................................................1-105
1553534-6 ........................................................1-105
1553534-7 ........................................................1-105
1553534-8 ........................................................1-105
1553534-9 ........................................................1-105
1553608-1 .........................................................1-105
1553608-2 ........................................................1-105
1553609-1 .........................................................1-105
1553609-2 ........................................................1-105
1553635-1 ..........................................................1-105
1553635-2 ........................................................1-105

1553636-1 .........................................................1-105
1553636-2 ........................................................1-105
1553640-1 .........................................................1-105
1553640-2 .......................................................1-105
1553640-3 .......................................................1-105
1553640-4 .......................................................1-105
1553640-5 .......................................................1-105
1553640-6 .......................................................1-105
1553640-7 ........................................................1-105
1553640-8 .......................................................1-105
1553640-9 .......................................................1-105
1553657-1 ..........................................................1-103
1553657-2 .........................................................1-103
1553658-1 .........................................................1-104
1553676-1 ..........................................................1-105
1553676-2 ........................................................1-105
1553677-1 ..........................................................1-105
1553677-2 .........................................................1-105
1553678-1 ..........................................................1-105
1553678-2 ........................................................1-105
1553761-1 ...........................................................1-103
1553785 .............................................................. 1-131
1583236-1 .........................................................3-116
1583608-1 .........................................................3-116
1588175-1 ........................................................... 1-133
1588176-1 ........................................................... 1-133
1591020-1 ...........................................................3-78
1591022-1 ...........................................................3-78
1591024-1 ...........................................................3-77
1591026-1 ...........................................................3-77
1591030-1 ...........................................................3-77
1591032-1 ...........................................................3-78
1591034-0 .........................................................3-78
1591070-1 ...........................................................3-75
1591081-1 ............................................................3-75
1591083-1 ...........................................................3-75
1591093-1 ...........................................................3-75
1591094-0 .........................................................3-76
1591095-0 .........................................................3-76
1591096-0 .........................................................3-76
1591097-0 ..........................................................3-76
1591098-0 .........................................................3-76
1591099-1 ...........................................................3-76
1591185-0 ...........................................................3-79
1591188-1 .............................................................3-79
1591311-1 ..............................................................3-72
1591311-2 .............................................................3-72
1591311-6 .............................................................3-72
1591311-7 .............................................................3-72
1671189-2 ........................................................... 3-67
1671200-1 ..........................................................3-66
1671205-3 ......................................................... 3-65
1671205-4 ......................................................... 3-65

1671206-3 ......................................................... 3-65
1671206-4 ......................................................... 3-65
1671207-3..........................................................3-66
1671207-4 .........................................................3-66
1671226-5.......................................................... 3-65
1671227-5 .......................................................... 3-65
1673956-1.......................................................... 3-115
1695790-4 .........................................................1-52
1711160-2 ...............................................3-10, 3-128
1711295-2 ............................................................ 3-10
1711342-2 ...............................................3-10, 3-128
1711343-2 ............................................................ 3-10
1711970-1 ............................................................ 3-65
1711987-1 ............................................................3-66
1725150-1 ........................................................... 3-115
1725150-3 ......................................................... 3-115
1754074-1 ......................................................... 1-132
1754136-1 ........................................................... 1-133
1754137-1 ........................................................... 1-133
1754138-1 ...........................................................1-126
1754371-2 ................................... 1-139, 1-140, 2-4
1754371-4 .......................................................... 1-141
1754462-1 ......................................................... 1-127
1754765-1 ........................................................... 1-131
1754766-1 ........................................................... 1-131
1754767-1 ........................................................... 1-131
1754768-1 ........................................................... 1-131
1754845-1 .............................................1-124, 1-125
1754845-2 ............................................1-124, 1-125
1777029-1.......................................................... 3-58
1777040-1 ......................................................... 3-59
1777046-1 ......................................................... 3-56
1777052-1 .......................................................... 3-58
1777054-1 ......................................................... 3-59
1777125-1 ........................................................... 3-85
1777126-1 .........................................................3-100
1777127-1 ..............................................................2-6
1777127-2 .............................................................2-6
1777127-3 .............................................................2-6
1777127-4 .............................................................2-6
1777127-5 .............................................................2-6
1777127-6 .............................................................2-6
1777127-7 .............................................................2-6
1777127-8 .............................................................2-6
1777127-9 .............................................................2-6
1777215-1 ...........................................................3-99
1777215-2 ..........................................................3-99
1777224-1 ..........................................................3-99
1777265-1 .............................................................2-6
1777265-2 ............................................................2-6
1777265-3 ............................................................2-6
1777265-4 ...........................................................2-6
1777265-5............................................................2-6

Sc9_Index_v1.indd   20

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-21

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

1777265-6 ...........................................................2-6
1777265-7 ............................................................2-6
1777265-8 ...........................................................2-6
1777265-9 ...........................................................2-6
1777266-1 .............................................................2-6
1777266-2 ...........................................................2-6
1777266-3 ...........................................................2-6
1777266-4 ...........................................................2-6
1777266-5 ...........................................................2-6
1777266-6 ...........................................................2-6
1777266-7 ............................................................2-6
1777266-8 ...........................................................2-6
1777266-9 ...........................................................2-6
1828078-1 ............................................................2-4
1828078-2 ...........................................................2-4
1828078-3 ...........................................................2-4
1828078-4 ...........................................................2-4
1828078-5 ...........................................................2-4
1828078-6 ...........................................................2-4
1828078-7 ...........................................................2-4
1828078-8 ...........................................................2-4
1828078-9 ...........................................................2-4
1828079-1 ............................................................2-4
1828079-2 ...........................................................2-4
1828079-3 ...........................................................2-4
1828079-4...........................................................2-4
1828079-5 ...........................................................2-4
1828079-6 ...........................................................2-4
1828079-7 ...........................................................2-4
1828079-8 ...........................................................2-4
1828079-9 ...........................................................2-4
1828833-1 .......................................................... 1-131
1828834-1 .......................................................... 1-131
1828835-1 .......................................................... 1-131
1828836-1 .......................................................... 1-131
1828837-1 ........................................................... 1-131
1828856-1 ............................................................ 2-3
1828856-2 ........................................................... 2-3
1828856-3 ........................................................... 2-3
1828856-4 ........................................................... 2-3
1828856-5 ........................................................... 2-3
1828856-6 ........................................................... 2-3
1828856-7 ........................................................... 2-3
1828856-8 ........................................................... 2-3
1828856-9 ........................................................... 2-3
1828860-1 ............................................................ 2-3
1828860-2 .......................................................... 2-3
1828860-3 .......................................................... 2-3
1828860-4 .......................................................... 2-3
1828860-5 .......................................................... 2-3
1828860-6 .......................................................... 2-3
1828860-7 ........................................................... 2-3
1828860-8 .......................................................... 2-3

1828860-9 .......................................................... 2-3
1828861-1 ..............................................................2-4
1828861-2 ............................................................2-4
1828861-3 ............................................................2-4
1828861-4 ............................................................2-4
1828861-5 ............................................................2-4
1828861-6 ............................................................2-4
1828861-7 ............................................................2-4
1828861-8 ............................................................2-4
1828861-9 ............................................................2-4
1828862-1 ............................................................2-4
1828862-2 ...........................................................2-4
1828862-3 ...........................................................2-4
1828862-4 ...........................................................2-4
1828862-5 ...........................................................2-4
1828862-6 ...........................................................2-4
1828862-7 ...........................................................2-4
1828862-8 ...........................................................2-4
1828862-9 ...........................................................2-4
1828867-1 ..........................................................1-139
1828867-2 ........................................................1-139
1828867-3 ........................................................1-139
1828868-1 .........................................................1-140
1828868-2 ........................................................1-140
1828868-3 ........................................................1-140
1828869-1 .......................................................... 1-141
1828869-2 ......................................................... 1-141
1828869-3 ......................................................... 1-141
1871456-1 ..........................................................2-20
1871456-2 .........................................................2-20
1871456-3 .........................................................2-20
1871456-4 .........................................................2-20
1871696-1 .......................................................... 1-127
1907489-3 ......................................................... 1-141
1907490-3 .......................................................1-139
1907491-3 .........................................................1-140
1907492-3 ......................................................... 1-141
1907493-3 ........................................................1-139
1907494-3 ........................................................1-140
1907495-3 ......................................................... 1-141
1907496-3 ........................................................1-139
1907497-3 ........................................................1-140
1918652-1 ........................................................... 1-128
1918777-2 ............................................................2-14
1918777-3 ............................................................2-14
1918777-4 ...........................................................2-14
1918777-5 ............................................................2-14
1918777-6............................................................2-14
1918777-7 ............................................................2-14
1918777-8 ............................................................2-14
1918777-9............................................................2-14
1918778-2 ...........................................................2-14
1918778-3 ...........................................................2-14

1918778-4 ...........................................................2-14
1918778-5 ...........................................................2-14
1918778-6 ...........................................................2-14
1918778-7 ............................................................2-14
1918778-8 ...........................................................2-14
1918778-9 ...........................................................2-14
1918779-2 ...........................................................2-14
1918779-3 ...........................................................2-14
1918779-4 ...........................................................2-14
1918779-5 ...........................................................2-14
1918779-6 ...........................................................2-14
1918779-7 ............................................................2-14
1918779-8 ...........................................................2-14
1918779-9 ...........................................................2-14
1918780-2 ...........................................................2-14
1918780-3 ...........................................................2-14
1918780-4 ...........................................................2-14
1918780-5 ...........................................................2-14
1918780-6 ...........................................................2-14
1918780-7 ...........................................................2-14
1918780-8 ...........................................................2-14
1918780-9 ...........................................................2-14
1918781-2 .............................................................2-14
1918781-3 .............................................................2-14
1918781-4 ............................................................2-14
1918781-5 .............................................................2-14
1918781-6 ............................................................2-14
1918781-7 .............................................................2-14
1918781-8 ............................................................2-14
1918781-9 ............................................................2-14
1918782-2 ...........................................................2-14
1918782-3 ...........................................................2-14
1918782-4 ...........................................................2-14
1918782-5 ...........................................................2-14
1918782-6 ...........................................................2-14
1918782-7 ............................................................2-14
1918782-8 ...........................................................2-14
1918782-9 ...........................................................2-14
1918783-2 ...........................................................2-14
1918783-3 ...........................................................2-14
1918783-4 ...........................................................2-14
1918783-5 ...........................................................2-14
1918783-6 ...........................................................2-14
1918783-7 ............................................................2-14
1918783-8 ...........................................................2-14
1918783-9 ...........................................................2-14
1918784-2 ...........................................................2-14
1918784-3 ...........................................................2-14
1918784-4 ...........................................................2-14
1918784-5 ...........................................................2-14
1918784-6 ...........................................................2-14
1918784-7 ...........................................................2-14
1918784-8 ...........................................................2-14

Sc9_Index_v1.indd   21

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-22

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

1918784-9 ...........................................................2-14
1918785-2 ............................................................ 2-7
1918785-3 ............................................................ 2-7
1918785-4 ............................................................ 2-7
1918785-5 ............................................................ 2-7
1918785-6 ............................................................ 2-7
1918785-7 ............................................................. 2-7
1918785-8 ............................................................ 2-7
1918785-9 ............................................................ 2-7
1918786-2 ............................................................ 2-7
1918786-3 ............................................................ 2-7
1918786-4 ............................................................ 2-7
1918786-5 ............................................................ 2-7
1918786-6 ............................................................ 2-7
1918786-7 ............................................................ 2-7
1918786-8 ............................................................ 2-7
1918786-9 ............................................................ 2-7
1918802-1 ..........................................................1-134
1918803-1 ..........................................................1-134
1918804-1 ..........................................................1-134
1918805-1 ..........................................................1-134
1918806-1 ..........................................................1-134
1918807-1 .......................................................... 1-135
1918808-1 .......................................................... 1-135
1918809-1 ..........................................................1-134
1918810-1 ........................................................... 1-135
1918811-1 ............................................................. 1-135
1933084-1 .........................................................3-94
1933085-1 .........................................................3-94
1933096-1 ......................................................... 4-22
1933134-1 ............................................... 1-122, 4-17
1933134-2 ...........................................................4-17
1933134-4 ...........................................................4-17
1933172-1 ............................................................ 4-14
1933172-2 ........................................................... 4-14
1933172-3 ........................................................... 4-14
1933172-4 .......................................................... 4-14
1933192-1 ........................................................... 4-22
1933193-1 ........................................................... 4-22
1933194-1 .......................................................... 4-22
1933198 ............................................................ 3-109
1933199 ............................................................ 3-109
1933285-1 ............................................................2-5
1933285-2 ...........................................................2-5
1933285-3 ...........................................................2-5
1933285-4 ...........................................................2-5
1933285-5 ...........................................................2-5
1933285-6 ...........................................................2-5
1933285-7 ...........................................................2-5
1933285-8 ...........................................................2-5
1933285-9 ...........................................................2-5
1933286-3 .............................................1-119, 4-22
1933286-4 .............................................1-119, 4-22

1933286-6 ........................................................ 4-22
1933307 .......................................................... 3-109
1933307-1 ......................................................... 3-82
1933308 .......................................................... 3-109
1933308-1 ......................................................... 3-82
1933309 .......................................................... 3-109
1933309-1 ......................................................... 3-82
1933310 ........................................................... 3-109
1933310-1 .......................................................... 3-82
1933319 ............................................................ 3-109
1933319-2 .............................................. 3-8, 3-128
1933320 .......................................................... 3-109
1933320-2 ............................................. 3-8, 3-128
1933321 ............................................................ 3-109
1933321-2............................................... 3-8, 3-128
1933322 ........................................................... 3-109
1933322-2 ............................................. 3-8, 3-128
1933352 ..........................................................   6-26
1933352-1 .......................................................... 3-58
1933352-2 .........................................  3-58, 6-26
1933352-3 .........................................  3-58, 6-26
1933352-4 .........................................  3-58, 6-26
1933412 ............................................................ 3-109
1933412-1 ........................................................... 3-82
1933422-1 ............................................................2-5
1933422-2 ...........................................................2-5
1933422-3 ...........................................................2-5
1933422-4 ...........................................................2-5
1933422-5 ...........................................................2-5
1933422-6 ...........................................................2-5
1933422-7 ...........................................................2-5
1933422-8 ...........................................................2-5
1933422-9 ...........................................................2-5
1933424-2 ........................................................4-24
1933425-1 .......................................................  6-25
1933443-1 .........................................................3-64
1933455-2 ......................................................... 3-41
1933455-6 ......................................................... 3-41
1933455-7 ......................................................... 3-41
1933455-8 ......................................................... 3-41
1933455-9 ......................................................... 3-41
1933457-1* ........................................................ 3-39
1933458-1* ....................................................... 3-22
1933468-1 .........................................................4-20
1933468-2 ........................................................4-20
1933468-4 .......................................................4-20
1933476-X ......................................................... 3-10
1933530-1 ........................................................  6-19
1933531-1 ..........................................................  6-19
1933532-1 ...................1-142, 1-143, 1-144, 1-145,  

................3-125, 3-126, 3-127, 3-128, 6-19

1933533-1...................1-142, 1-143, 1-144, 1-145,  
 

 ................3-125, 3-126, 3-127, 3-128, 6-19

1933534 ............................................................1-142
1933534-1 .................1-143, 1-144, 1-145, 3-125,  
 

 ........................... 3-126, 3-127, 3-128, 6-20

1933535-1 .......................................................  6-20
1933536-1 ......................................................  6-20
1933540 .........................................................  6-20
1933540-1 ..................1-142, 1-143, 1-144, 1-145,  
 

 ...........................3-125, 3-126, 3-127, 3-128

1933541-1 ........................................................  6-20
1933542-1 ......................................................  6-20
1933552-1 .........................................................  6-21
1933553-1.........................................................  6-21
1933554-1 ........................................................  6-21
1933555-1.........................................................  6-21
1933556-1 ........................................................  6-21
1933557-1 .........................................................  6-21
1933558-1 ........................................................  6-21
1933559-1 ..................1-142, 1-143, 1-144, 1-145,  
 

 ................3-125, 3-126, 3-127, 3-128, 6-18

1933560-1 ........................................................  6-18
1933561-1 ..........................................................  6-19
1933562-1 ........................................................  6-19
1933566-1 ........................................................  6-19
1933567-1 .........................................................  6-19
1933570-1 ..................1-142, 1-143, 1-144, 1-145,  

................3-125, 3-126, 3-127, 3-128, 6-18

1933582-1.......................................................... 4-22
1933636-2 ........................................................4-24
1933657-1* ........................................................ 3-39
1933658-1* ....................................................... 3-22
1933659-1 ......................................................... 4-22
1933659-2 ........................................................ 4-22
1933661-1........................................................... 4-22
1933668- .................3-125, 3-126, 3-127, 3-128
1933668-1 ...........................................................4-12
1933668-2 ..........................................................4-12
1933668-4 .........................................................4-12
1933671- ...................3-125, 3-126, 3-127, 3-128
1933671-1 .............................................................4-12
1933671-2 ...........................................................4-12
1933671-4 ...........................................................4-12
1933674-1 ............................................................4-12
1933674-2 ..........................................................4-12
1933674-4 ..........................................................4-12
1933677-1 ............................................................4-12
1933686-1 ............................................................4-5
1933686-2 ...........................................................4-5
1933686-4 ..........................................................4-5
1933776 ........................................................... 3-109
1933880-X ....................................................... 3-53
1933881-X ......................................................... 3-53
1933882-X ........................................................ 3-53
1933883-X ........................................................ 3-53

Sc9_Index_v1.indd   22

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-23

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

1933884-X ....................................................... 3-53
1933885-X ........................................................ 3-53
1933886-X ....................................................... 3-53
1933887-X ........................................................ 3-53
1933888-X........................................................ 3-53
1933895-1 ......................................................... 3-97
1933981-1.........................................................3-100
1938056-2..........................................................2-14
1938056-3 .........................................................2-14
1938056-4 .........................................................2-14
1938056-5 .........................................................2-14
1938056-6 .........................................................2-14
1938056-7 ..........................................................2-14
1938056-8 .........................................................2-14
1938056-9 .........................................................2-14
1938965-2 ..........................................................2-14
1938965-3 ..........................................................2-14
1938965-4 .........................................................2-14
1938965-5 ..........................................................2-14
1938965-6 ..........................................................2-14
1938965-7 ..........................................................2-14
1938965-8 ..........................................................2-14
1938965-9 ..........................................................2-14
1938966-2 ........................................................... 2-7
1938966-3 ........................................................... 2-7
1938966-4 .......................................................... 2-7
1938966-5 ........................................................... 2-7
1938966-6 .......................................................... 2-7
1938966-7 ........................................................... 2-7
1938966-8 .......................................................... 2-7
1938966-9 .......................................................... 2-7
1938967-2 ........................................................... 2-7
1938967-3 ........................................................... 2-7
1938967-4 ........................................................... 2-7
1938967-5 ........................................................... 2-7
1938967-6 ........................................................... 2-7
1938967-7 ........................................................... 2-7
1938967-8 ........................................................... 2-7
1938967-9 ........................................................... 2-7
1938996-2 ..........................................................2-14
1938996-3 ..........................................................2-14
1938996-4 .........................................................2-14
1938996-5 ..........................................................2-14
1938996-6 .........................................................2-14
1938996-7 ..........................................................2-14
1938996-8 .........................................................2-14
1938996-9 .........................................................2-14
1985040-1 ......................................................... 1-131
1985041-1 ........................................................... 1-131
1985713-2............................................................. 2-7
1985713-3 ............................................................ 2-7
1985713-4 ............................................................ 2-7
1985713-5 ............................................................ 2-7

1985713-6 ............................................................ 2-7
1985713-7 ............................................................. 2-7
1985713-8 ............................................................ 2-7
1985713-9 ............................................................ 2-7
1985766-1 ......................................................... 1-133
1985771-1 ...........................................................1-126
1985797-2 ............................................................ 2-7
1985797-3............................................................ 2-7
1985797-4 ........................................................... 2-7
1985797-5............................................................ 2-7
1985797-6 ........................................................... 2-7
1985797-7 ............................................................ 2-7
1985797-8 ........................................................... 2-7
1985797-9 ........................................................... 2-7
1985798-2 ........................................................... 2-7
1985798-3 ........................................................... 2-7
1985798-4 ........................................................... 2-7
1985798-5 ........................................................... 2-7
1985798-6 ........................................................... 2-7
1985798-7 ........................................................... 2-7
1985798-8 ........................................................... 2-7
1985798-9 ........................................................... 2-7
1985799-2 ........................................................... 2-7
1985799-3 ........................................................... 2-7
1985799-4 ........................................................... 2-7
1985799-5 ........................................................... 2-7
1985799-6 ........................................................... 2-7
1985799-7 ........................................................... 2-7
1985799-8 ........................................................... 2-7
1985799-9 ........................................................... 2-7
1985959-1 ............................................................ 2-3
1985959-2 ........................................................... 2-3
1985959-3 ........................................................... 2-3
1985959-4........................................................... 2-3
1985959-5 ........................................................... 2-3
1985959-6 ........................................................... 2-3
1985959-7 ........................................................... 2-3
1985959-8 ........................................................... 2-3
1985959-9 ........................................................... 2-3
1985960-1 ............................................................ 2-3
1985960-2 .......................................................... 2-3
1985960-3 .......................................................... 2-3
1985960-4 .......................................................... 2-3
1985960-5 .......................................................... 2-3
1985960-6 .......................................................... 2-3
1985960-7........................................................... 2-3
1985960-8 .......................................................... 2-3
1985960-9 .......................................................... 2-3
1985961-1 ............................................................. 2-3
1985961-2 ............................................................ 2-3
1985961-3 ............................................................ 2-3
1985961-4 ............................................................ 2-3
1985961-5 ............................................................ 2-3

1985961-6 ............................................................ 2-3
1985961-7 ............................................................ 2-3
1985961-8 ............................................................ 2-3
1985961-9 ............................................................ 2-3
1FM-(3)ØE-AMP-LAB ...................................4-7
1FM-(4)ØE-AMP ..............................................4-7
1FM-(4)ØE-AMP-LAB ..................................4-7
1FM-(6)ØE-AMP ..............................................4-7
1FM-(6)ØE-AMP-LAB...................................4-7
1FM-ØE-AMP-LAB .........................................4-7
1FM-ØE-AMP-PHONE ..................................4-7
1FM-ØØE-AMP .................................................4-7
1FM-ØØE-AMP-LAB .....................................4-7

2

2-1374416-3 .....................................................4-23
2-1374416-4 .....................................................4-23
2-1374416-5 .....................................................4-23
2-1374416-6 .....................................................4-23
2-1375055-1 ..................................................... 3-23
2-1375055-2 .................................................... 3-23
2-1375055-4 .................................................... 3-23
2-1375055-5 .................................................... 3-23
2-1375055-6 .................................................... 3-23
2-1375055-7 .................................................... 3-23
2-1375055-8 .................................................... 3-23
2-1375055-9 .................................................... 3-23
2-1375191-1 ......................................................... 3-41
2-1375191-2 ........................................................ 3-41
2-1375191-4 ....................................................... 3-41
2-1375191-5 ........................................................ 3-41
2-1375191-6 ....................................................... 3-41
2-1375191-7 ........................................................ 3-41
2-1375191-8 ....................................................... 3-41
2-1375191-9 ....................................................... 3-41
2-1499841-0 ......................................................2-19
2-1499841-5 ......................................................2-19
2-1499842-0 .....................................................2-19
2-1499842-5 .....................................................2-19
2-1499843-0 .....................................................2-19
2-1499843-5 .....................................................2-19
2-1499844-0 ....................................................2-19
2-1499844-5 .....................................................2-19
2-1499845-0 .....................................................2-19
2-1499845-5 .....................................................2-19
2-1499846-0 ....................................................2-19
2-1499846-5 .....................................................2-19
2-1499848-0 ....................................................2-19
2-1499848-5 .....................................................2-19
2-1499849-0 ....................................................2-19
2-1499849-5 .....................................................2-19
2-1499850-0 ....................................................2-19
2-1499850-5 .....................................................2-19

Sc9_Index_v1.indd   23

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-24

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

2-1499851-0 ......................................................2-19
2-1499851-5 .......................................................2-19
2-1499852-0 .....................................................2-19
2-1499852-5 .....................................................2-19
2-1499853-0 .....................................................2-19
2-1499853-5 .....................................................2-19
2-1591019-0 ......................................................3-76
2-1777117-7 .......................................................1-142
2-1777121-7 .......................................................1-142
2-2111179-0 ..............................................1-117, 2-21
2-2111190-0..............................................1-117, 2-21
2-2111225-0 .............................................1-117, 2-21
2-2111236-0 .............................................1-117, 2-21
2-2111250-5 ...................................................... 3-62
2-2111250-6 ...................................................... 3-62
2-2111270-5 ...................................................... 3-62
2-2111270-6 ...................................................... 3-62
2-2111280-5 ...................................................... 3-62
2-2111280-6 ...................................................... 3-62
2-2111290-5 ....................................................... 3-61
2-2111290-6 ....................................................... 3-61
2-2111300-5 ...................................................... 3-61
2-2111300-6 ...................................................... 3-61
2-2111310-5 ........................................................ 3-61
2-2111310-6 ........................................................ 3-61
2-2111408-4 .....................................................4-23
2-2111501-0 ........................................................3-72
2-2111505-0 ......................................................3-72
2-2111510-0 ........................................................3-72
2-2111515-0 ........................................................3-72
2-231652-1 .......................................................3-120
2-231652-7 ......................................................3-120
2-231652-8 .....................................................3-120
2-603227-0 .........................................1-137, 3-101
2-603227-9 .........................................1-137, 3-101
2-604751-0 ..........................................1-137, 3-101
2-604751-9 ..........................................1-137, 3-101
2-604771-0..........................................1-137, 3-101
2-604771-9 ..........................................1-137, 3-101
2-604772-0 ........................................1-137, 3-101
2-604772-9 .........................................1-137, 3-101
2064499-1 .......................................................1-136
2064500-1 .......................................................1-136
2064540-1 .......................................................1-126
2064603-1 ....................................................... 1-133
2064651-1 .........................................................1-136
2064651-2 .......................................................1-136
2064651-3 .......................................................1-136
2111008 ............................................................ 3-108
2111008- ................................3-125, 3-126, 3-128
2111009 ............................................................ 3-108
2111009- ................................3-125, 3-126, 3-128
2111010 .............................................................. 3-108

2111011 ............................................................... 3-108
2111011- ....................................3-125, 3-126, 3-128
2111012 .............................................................. 3-108
2111013 .............................................................. 3-108
2111014 .............................................................. 3-108
2111015 .............................................................. 3-108
2111021 .............................................................. 3-108
2111022 ............................................................. 3-108
2111023 ............................................................. 3-108
2111024 ............................................................. 3-108
2111025 ............................................................. 3-108
2111036- ............................................................ 3-127
2111037- ............................................................ 3-127
2111039- ............................................................ 3-127
2111093-1 ............................................................ 3-65
2111117-1 ............................................................... 3-65
2111121-1 ................................................................ 3-41
2111122-1 ............................................................... 3-41
2111123-1 ............................................................. 3-24
2111124-1 ............................................................. 3-24
2111159-1 ............................................................. 3-82
2111179-1 ....................................................1-117, 2-21
2111179-2 ...................................................1-117, 2-21
2111179-3 ...................................................1-117, 2-21
2111179-4 ...................................................1-117, 2-21
2111179-5 ...................................................1-117, 2-21
2111179-6 ...................................................1-117, 2-21
2111179-7 ...................................................1-117, 2-21
2111179-8 ...................................................1-117, 2-21
2111179-9 ...................................................1-117, 2-21
2111190-1 ....................................................1-117, 2-21
2111190-2...................................................1-117, 2-21
2111190-3 ..................................................1-117, 2-21
2111190-4 ..................................................1-117, 2-21
2111190-5 ..................................................1-117, 2-21
2111190-6 ..................................................1-117, 2-21
2111190-7 ...................................................1-117, 2-21
2111190-8 ..................................................1-117, 2-21
2111190-9 ..................................................1-117, 2-21
2111225-1 ...................................................1-117, 2-21
2111225-2 ..................................................1-117, 2-21
2111225-3 ..................................................1-117, 2-21
2111225-4 ..................................................1-117, 2-21
2111225-5 ..................................................1-117, 2-21
2111225-6 ..................................................1-117, 2-21
2111225-7 ..................................................1-117, 2-21
2111225-8 ..................................................1-117, 2-21
2111225-9 ..................................................1-117, 2-21
2111236-1 ...................................................1-117, 2-21
2111236-2 ..................................................1-117, 2-21
2111236-3 ..................................................1-117, 2-21
2111236-4 .................................................1-117, 2-21
2111236-5 ..................................................1-117, 2-21

2111236-6 ..................................................1-117, 2-21
2111236-7 ..................................................1-117, 2-21
2111236-8 ..................................................1-117, 2-21
2111236-9 ..................................................1-117, 2-21
2111250-7 ........................................................... 3-62
2111251-5 ............................................................ 3-62
2111252-5 ........................................................... 3-62
2111270-7 ........................................................... 3-62
2111271-5 ............................................................ 3-62
2111272-5 ........................................................... 3-62
2111279-1 ..........................................................  6-23
2111280-7 ........................................................... 3-62
2111281-5 ............................................................ 3-62
2111282-5 ........................................................... 3-62
2111285-2 ........................................................... 3-87
2111290-7............................................................ 3-61
2111291-5 ............................................................. 3-61
2111292-5 ............................................................ 3-61
2111300-7 ........................................................... 3-61
2111301-5 ............................................................. 3-61
2111302-5 ........................................................... 3-61
2111310-7 ............................................................. 3-61
2111311-5 .............................................................. 3-61
2111312-5 ............................................................. 3-61
2111340-1 ............................................................3-79
2111348-1 ............................................................ 3-82
2111349-1 ............................................................ 3-82
2111399-1 ............................................................3-43
2111407-2...........................................................4-23
2111407-5 ..........................................................4-23
2111407-6 ..........................................................4-23
2111407-7 ...........................................................4-23
2111407-8 ..........................................................4-23
2111408-1 ...........................................................4-23
2111408-2 ..........................................................4-23
2111408-5 ..........................................................4-23
2111408-6 ..........................................................4-23
2111408-7 ..........................................................4-23
2111408-8 ..........................................................4-23
2111408-9 ..........................................................4-23
2111413-1 ........................................................... 3-106
2111414-1 ........................................................... 3-106
2111415-1 .............................................3-104, 3-106
2111416-1 ........................................................... 3-104
2111481-1 .............................................................1-104
2111500-2 .......................................................... 4-22
2111570-1 ...............................................................3-8
2111571-1 .................................................................3-8
2111572-1 ................................................................3-8
2111573-1................................................................3-8
2111615-1 ............................................................. 4-22
2111615-2 ............................................................ 4-22
2111648-1 ............................................................1-105

Sc9_Index_v1.indd   24

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-25

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

2111649-1 ............................................................1-105
2111649-2 ..........................................................1-105
2111650-1 ............................................................1-105
2111650-2 ..........................................................1-105
2111651-1 .............................................................1-105
2111653-1 ............................................................3-69
2111653-2 ...........................................................3-69
2111653-3 ...........................................................3-69
2111653-5 ...........................................................3-69
2111653-7 ...........................................................3-69
2111673-1 ............................................................3-69
2111673-2 ...........................................................3-69
2111673-3 ...........................................................3-69
2111673-5 ...........................................................3-69
2111676-X............................................................ 3-10
2123273-1 ........................................................... 1-131
2153041-1 ..........................................................3-54
2153046-1 .........................................................3-54
2153115-1 ............................................................ 3-65
219172-1 ..............................................................3-98
219172-2 ............................................................3-98
219172-3 ............................................................3-98
219172-4 ............................................................3-98
219173-1 ..............................................................3-98
219173-2 ............................................................3-98
219173-3 ............................................................3-98
219173-4 ............................................................3-98
219174-1 ..................................................1-123, 3-98
219174-2 ................................................1-123, 3-98
219174-3 ................................................1-123, 3-98
219174-4 ................................................1-123, 3-98
219175-1 ..................................................1-123, 3-98
219175-2 ................................................1-123, 3-98
219175-3 ................................................1-123, 3-98
219175-4 ................................................1-123, 3-98
2193016-1 ..........................................................1-105
2193045-1 .........................................................1-105
2193046-1 .........................................................1-105
2193046-2 .......................................................1-105
2193047-1 .........................................................1-105
2193047-2 ........................................................1-105
2193048-1 .........................................................1-105
2193048-2 .......................................................1-105
2193050-1 .........................................................1-105
2193051-1 ..........................................................1-105
2193052-1 .........................................................1-105
2193053-1 .........................................................1-105
2193053-2 ........................................................1-105
2193054-1 .........................................................1-105
2193054-2 ........................................................1-105
2193055-1 .........................................................1-105
2193055-2 ........................................................1-105
2193056-1 .........................................................1-105

2193056-2 ........................................................1-105
2193057-1..........................................................1-105
2193057-2 ........................................................1-105
2193057-3 ........................................................1-105
2193057-4 ........................................................1-105
2193058-1 .........................................................1-105
2193058-2 ........................................................1-105
2193058-4 .......................................................1-105
224928-1 ...........................................................3-118
224928-2 ..........................................................3-118
228433-5..........................................................1-130
228433-7 ..........................................................1-130
228433-8 .........................................................1-130
228433-9 .........................................................1-130
229378-1 ..........................................................3-123
229384-1 ..........................................................3-123
229451-2 ..........................................................3-123
229764-2 .........................................................3-123
230238-1 ..........................................................3-123
230328-3 ........................................................3-123
231662-5 ........................................................... 3-121
231666-9 .......................................................... 3-121
231890-1 ...........................................................3-122
2FM-(6)ØE-AMP-LAB .................................4-7
2FM-(12)ØE-AMP-LAB ................................4-7
2FM-D(4)ØE-AMP .........................................4-7
2FM-D(6)ØE-AMP .........................................4-7
2FM-DØØE-AMP ............................................4-7

3

3-1375055-0 ................................................... 3-23
3-1375055-1 ..................................................... 3-23
3-1375055-3 .................................................... 3-23
3-1375191-0 ....................................................... 3-41
3-1375191-1 ......................................................... 3-41
3-1375191-3........................................................ 3-41
3-1499841-0 ......................................................2-19
3-1499842-0 .....................................................2-19
3-1499843-0 ....................................................2-19
3-1499844-0 ....................................................2-19
3-1499845-0.....................................................2-19
3-1499846-0 ....................................................2-19
3-1499848-0 ....................................................2-19
3-1499849-0 ....................................................2-19
3-1499850-0 ....................................................2-19
3-1499851-0 ......................................................2-19
3-1499852-0 .....................................................2-19
3-1499853-0 .....................................................2-19
3-1553307-9 ....................................................1-143
3-1553308-9 ...................................................1-143
3-1553311-9 ......................................................1-143
3-1553312-9 .....................................................1-143
3-1553315-9 .....................................................1-143

3-1553316-9 .....................................................1-143
3-1553416-9 .....................................................1-143
3-1553417-9 .....................................................1-143
3-1553418-9 ........................................1-143, 1-144
3-1553419-9 .....................................................1-143
3-1553420-9 ...................................................1-143
3-1777117-7 .......................................................1-143
3-1777121-7 .......................................................1-143
3-231652-0 .....................................................3-120
3-231652-6 .....................................................3-120
354940-1 ..............................................3-118, 3-119

4

4-1499783-0 ...................................................3-98
4-1499841-0 ......................................................2-19
4-1499842-0 ....................................................2-19
4-1499843-0 ....................................................2-19
4-1499844-0 ....................................................2-19
4-1499845-0 ....................................................2-19
4-1499846-0 ....................................................2-19
4-1499848-0 ....................................................2-19
4-1499849-0 ....................................................2-19
4-1499850-0 ....................................................2-19
4-1499851-0 ......................................................2-19
4-1499852-0 .....................................................2-19
4-1499853-0.....................................................2-19
4-1553307-9 ...................................................1-144
4-1553308-9 ...................................................1-144
4-1553311-9 ......................................................1-144
4-1553312-9 .....................................................1-144
4-1553315-9 .....................................................1-144
4-1553316-9 .....................................................1-144
4-1553416-9 ....................................................1-144
4-1553417-9 .....................................................1-144
4-1553419-9 ....................................................1-144
4-1553420-7 ...................................................1-145
4-1553420-9 ...................................................1-144
4-1777117-7 ............................................1-115, 1-145
4-1777121-7 ............................................1-115, 1-145
4-1777124-7 ...................................................... 1-115
4-1933335-0 ...................................................3-98
4-1933920-0...................................................3-98
4-1933921-0 ....................................................3-98
406042-1 ........................................................  6-25
406185 ............................................................. 3-108
406185-1 .................................................. 1-119, 4-6
406185-2 .............................................................4-6
406185-4 .............................................................4-6
406330 ........................................................... 3-109
406330-1 .......................................................... 3-39
406331 ............................................................. 3-109
406331-1 ........................................................... 3-39
406332 ........................................................... 3-109

Sc9_Index_v1.indd   25

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-26

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

406332-1 .......................................................... 3-39
406390 ........................................................... 3-109
406390-1 .......................................................... 3-39
406641-1 ...........................................................3-50
406771-1 ............................................................ 3-97
406771-2 .......................................................... 3-97
406772-1 ........................................................... 3-97
406788-1 .......................................................... 3-97
406981 ............................................................ 3-109
406981-1 ........................................................... 3-39
469439 .............................................................3-110
492025-1........................................................... 1-133
492026-1 .......................................................... 1-133
492131-1 ............................................................. 1-133
492622-1 ........................................................... 1-133
492623-1 ........................................................... 1-133
492697-1 ...............................................1-124, 1-125
492697-2 ..............................................1-124, 1-125
492703-1 ...........................................................1-126
492782-1 ........................................................... 1-133
492783-1 ........................................................... 1-133

5

5-1375202-2 .................................................... 3-24
5-1375202-3 .................................................... 3-24
5-1375204-2 .................................................... 3-24
5-1375204-3 .................................................... 3-24
5-1375351-1 ..................................................... 3-106
5-1375352-1 .................................................... 3-106
5-1375353-1 ...................................... 3-105, 3-106
5-1375354-1 ....................................... 3-59, 3-107
5-1375354-2 ...................................... 3-59, 3-107
5-1375354-3 ...................................... 3-59, 3-107
5-1375355-1* ...................................................3-107
5-1375356-1 ................................................... 3-104
5-1375357-1 .................................................... 3-104
5-1375358-1.....................................................3-105
5-1479002-1 ...................................................3-107
5-1479003-1 ...................................................3-107
5-1479184-2 ..................................................... 3-24
5-1479184-3 ..................................................... 3-24
5-1479185-2 ..................................................... 3-24
5-1479185-3 ..................................................... 3-24
5-1479802-3 .....................................................2-18
5-1479803-3 .....................................................2-18
5-1479804-3 .....................................................2-18
5-1479805-3 .....................................................2-18
5-1479806-3 .....................................................2-18
5-1479807-3 ......................................................2-18
5-1479808-3 .....................................................2-18
5-1479809-3 .....................................................2-18
5-1499549-3 .....................................................2-18
5-1499550-3 .....................................................2-18

5-1499551-3 .......................................................2-18
5-1499552-3 ......................................................2-18
5-1499553-3 .....................................................2-18
5-1499554-3 .....................................................2-18
5-1499555-3 .....................................................2-18
5-1499556-3 .....................................................2-18
5-1499557-3 ......................................................2-18
5-1499558-3 .....................................................2-18
5-1499559-3 .....................................................2-18
5-1499560-3 .....................................................2-18
5-1499561-3 .......................................................2-18
5-1499562-3 .....................................................2-18
5-1499675-3 ......................................................2-18
5-1499676-3 .....................................................2-18
5-1499677-3 ......................................................2-18
5-1499678-3 .....................................................2-18
5-1499679-3 .....................................................2-18
5-1499680-3 .....................................................2-18
5-1499783-0 ...................................................3-98
5-1499841-0 ......................................................2-19
5-1499842-0 .....................................................2-19
5-1499843-0.....................................................2-19
5-1499844-0 ....................................................2-19
5-1499845-0.....................................................2-19
5-1499846-0 ....................................................2-19
5-1499848-0 ....................................................2-19
5-1499849-0 ....................................................2-19
5-1499850-0 ....................................................2-19
5-1499851-0 ......................................................2-19
5-1499852-0 .....................................................2-19
5-1499853-0 .....................................................2-19
5-1899725-2 .......................................................5-6
5-1899725-3 .......................................................5-6
5-1899725-4 .......................................................5-6
5-1899725-5 .......................................................5-6
5-1899725-6 .......................................................5-6
5-1899725-7 .......................................................5-6
5-1899725-8 .......................................................5-6
5-1899725-9 .......................................................5-6
5-1933335-0 ...................................................3-98
5-1933920-0 ...................................................3-98
5-1933921-0.....................................................3-98
5-2111413-1 ....................................................... 3-106
5-2111414-1 ...................................................... 3-106
5-2111415-1 ....................................................... 3-104
5-2111416-1 ....................................................... 3-104
5-2111425-1...................................................... 3-106
5-554169-3 ......................................................3-88
5-554170-3 ......................................................3-88
5-554710-3 ......................................................3-88
5-554720-3 .....................................................3-88
5-554739-3 .....................................................3-88
5-555042-3 .....................................................3-88

5-555174-2 .......................................................3-88
5-555175-3 .......................................................3-88
5-555177-3 .......................................................3-88
5-555426-3 .....................................................3-88
5-557315-3 .......................................................3-88
5-558530-2 .....................................................3-42
5-558530-3 .....................................................3-42
5-569278-2 .....................................................3-42
5-569278-3 .....................................................3-42
5-569530-3 .....................................................3-88
5-569532-3 .....................................................3-88
5-569542-3 .....................................................3-88
5-569550-2 .....................................................3-42
5-569550-3 .....................................................3-42
5-569552-2 .....................................................3-42
5-569552-3 .....................................................3-42
5-641337-3 ......................................................3-88
501381-1 ...............................................................1-52
501473-3 ...........................................................1-129
501818-1 ............................................................. 1-132
502129-1 ............................................................1-130
502134-1 ............................................................1-130
502134-2 ..........................................................1-130
502222-1 ...........................................................1-130
502259-1 ........................................................... 1-132
502306-1 ............................................. 1-125, 1-130
502306-2 ............................................ 1-125, 1-130
502306-4............................................ 1-125, 1-130
502418-1 ............................................................1-129
502631-1 ............................................................ 1-132
502656-1 .......................................................... 1-132
502748-2 ..........................................................1-130
503273-5 ............................................................1-52
503304-1 .......................................................... 1-132
503337-1 ........................................................... 1-132
503746-1 ...............................................1-124, 1-127
503746-7 ..............................................1-124, 1-127
503887-1 ...........................................................1-130
503890-1 .......................................................... 1-133
503910-1 ........................................................... 1-133
503911-1 ............................................................. 1-133
503997 ............................................................ 3-108
503997-1 ...................................................1-121, 4-9
503997-3 ............................................................4-9
503998 ........................................................... 3-108
503998-1 .............................................................4-9
503999 ........................................................... 3-108
503999-1 ..................................................1-121, 4-9
503999-3 ............................................................4-9
504021-1 .............................................................1-52
504035-1 .......................................................... 1-128
504662-2 ...........................................................1-52
5502632-8.........................................................1-52

Sc9_Index_v1.indd   26

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-27

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

5502780-2 ........................................................1-52
5502780-3 ........................................................1-52
5503137-5 ..........................................................1-52
5504614-1 ...........................................................1-52
5504663-4 ........................................................1-52
5504640-1 .........................................................1-52
555049-1 ..........................................................3-86
555050-1 ..........................................................3-86
555051-1 ............................................................3-86
555052-1 ...........................................................3-86
555346-1 ............................................................ 3-81
555376-1 ...........................................................3-86
555377-1 ............................................................3-86
555383-1 ............................................................ 3-81
555482-1 ............................................................ 3-81
556180-1 ............................................................. 3-81
556183-1 ............................................................. 3-81
556186-1 ............................................................. 3-81
556189-1 ............................................................. 3-81
556222-3 ...............................................1-122, 4-16
556438-1 .........................................................  6-25
556625-1 ...........................................................3-86
556627-1 ...........................................................3-86
556706-1 ..........................................................3-122
556965-1 ........................................................... 3-82
556965-2 ......................................................... 3-82
556965-3 ......................................................... 3-82
556965-4 ......................................................... 3-82
556965-5 ......................................................... 3-82
557350-1 ..............................................................4-11
557361-1 ................................................................4-11
557366 ............................................................ 3-108
557366-1 ..............................................................4-11
557403-1 ...........................................................3-80
557429-1 ...........................................................3-84
557429-2 ..........................................................3-84
557548-1 .............................................. 3-58, 6-25
557685-1 ..............................................................4-11
557775-1 ...............................................................4-11
558106-1 ................................................. 1-122, 4-17
558106-2 ............................................................4-17
558106-4 ............................................................4-17
558107-1 ..............................................................4-17
558107-2 .............................................................4-17
558107-4.............................................................4-17
558191-1 .............................................................. 4-19
558191-2 ............................................................. 4-19
558191-4 ............................................................. 4-19
558198-1 ...........................................................3-102
558198-2 ..........................................................3-102
558198-3 ..........................................................3-102
558198-4 .........................................................3-102
558198-5 ..........................................................3-102

558198-6 .........................................................3-102
558198-7 ..........................................................3-102
558198-8..........................................................3-102
558198-9 .........................................................3-102
558199-1 ...........................................................3-102
558199-2 ..........................................................3-102
558199-3 ..........................................................3-102
558199-4 .........................................................3-102
558199-5 ..........................................................3-102
558199-6 .........................................................3-102
558199-7 ..........................................................3-102
558199-8 .........................................................3-102
558199-9 .........................................................3-102
558251-1 ............................................................. 4-13
558251-2 ............................................................ 4-13
558251-3 ............................................................ 4-13
558251-4 ............................................................ 4-13
558266-1 .........................................................  6-23
558267-1 .........................................................  6-23
558268-1 .........................................................  6-23
558269-1 .........................................................  6-23
558301-1 ..........................................................  6-25
558329-1 ........................................................   6-24
558331-1 .........................................................   6-24
558357-1 ............................................................ 4-19
558357-2 ........................................................... 4-19
558357-4 ........................................................... 4-19
558401-1 ............................................................3-46
558402-1 ..........................................................3-46
558417-1 ...........................................................3-107
558471-1 ..............................................................4-17
558471-2 .............................................................4-17
558471-4 .............................................................4-17
558488-1 ...........................................................4-20
558488-2 .........................................................4-20
558488-4 .........................................................4-20
558489-1...........................................................4-20
558489-2 .........................................................4-20
558489-4 .........................................................4-20
558492-1 ...........................................................4-20
558492-2 .........................................................4-20
558492-4 .........................................................4-20
558493-1 ...........................................................4-20
558493-2 .........................................................4-20
558493-4 .........................................................4-20
558527-1 ...........................................................3-43
558527-3 ..........................................................3-43
558635 ..............................................................3-110
558635-1 ...........................................................3-50
558637 ..............................................................3-110
558637-1 ...........................................................3-50
558639 ..............................................................3-110
558639-1 ...........................................................3-50

558821-1 ...........................................................3-102
558821-6 ..........................................................3-102
558821-8 ..........................................................3-102
558838-1 ........................................................... 3-47
558839 ..............................................................3-110
558839-1 ...........................................................3-46
558840 .............................................................3-110
558840-1 ..........................................................3-46
558841 ...............................................................3-110
558841-1 ............................................................3-46
558842 ..............................................................3-110
558842-1 ...........................................................3-46
558843 ..............................................................3-110
558843-1 ...........................................................3-46
558856-1 ........................................................... 3-85
558856-2 ......................................................... 3-85
558862-1 ........................................................... 3-85
558862-2.......................................................... 3-85
559369-1 ........................................................   6-24
559370-1 ........................................................   6-24
569127-1 ............................................................. 4-19
569127-2 ............................................................ 4-19
569127-4 ............................................................ 4-19
569389-1 ............................................. 3-49, 3-125
569431-1 ............................................................3-49
569432 ..............................................................3-110
569433 ..............................................................3-110
569433-1 ........................................................... 3-47
569434 .............................................................3-110
569434-1 .......................................................... 3-47
569438 ..............................................................3-110
569439-1 ............................................. 3-47, 3-125
569440 .............................................................3-110
569440-1 .......................................................... 3-47
569444 .............................................................3-110
569445..............................................................3-110
569445-1 ............................................. 3-47, 3-125
569446 .............................................................3-110
569446-1 .......................................................... 3-47
569499-1 ........................................................... 4-13
569499-2 .......................................................... 4-13
569499-3 .......................................................... 4-13
569499-4 .......................................................... 4-13
569523-2 ..........................................................3-45
569523-4 .........................................................3-45
569523-6 .........................................................3-45
569523-8..........................................................3-45
569524-2 ..........................................................3-45
569524-4 .........................................................3-45
569524-6 .........................................................3-45
569524-8 .........................................................3-45
569526-2 ..........................................................3-45
569526-4 .........................................................3-45

Sc9_Index_v1.indd   27

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-28

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

569526-6 .........................................................3-45
569526-8 .........................................................3-45
569527-2 ..........................................................3-45
569527-4 ..........................................................3-45
569527-6 ..........................................................3-45
569527-8 ..........................................................3-45
569528-2 ..........................................................3-45
569528-4 .........................................................3-45
569528-6 .........................................................3-45
569528-8 .........................................................3-45
569597-1 ...........................................................3-49
569599-1 ...........................................................3-49
569669-2 .........................................................3-45
569669-4 .........................................................3-45
569669-6 .........................................................3-45
569669-8 .........................................................3-45
569685-2 .........................................................3-45
569685-4 .........................................................3-45
569685-6 .........................................................3-45
569685-8 .........................................................3-45
569851-1 ............................................................3-49
569852-1 ...........................................................3-49
569853 ..............................................................3-110
569854 ..............................................................3-110
569854-1...........................................................3-48
569855 ..............................................................3-110
569855-1 ...........................................................3-48
569856 ..............................................................3-110
569857 ..............................................................3-110
569857-1 ...........................................................3-48
569858 ..............................................................3-110
569858-1 ...........................................................3-48
569875-1 ...........................................................3-43
569875-2 ..........................................................3-43
569875-3 ..........................................................3-43
569875-4 .........................................................3-43
569875-5 ..........................................................3-43
569875-6 .........................................................3-43
569875-7 ..........................................................3-43
569875-8..........................................................3-43
569875-9 .........................................................3-43
569949-1 .......................................................... 3-117
58424-1 ............................................................. 1-133
58433-4 ............................................................ 1-133
58551-1 ............................................................... 1-133
58552-1 .............................................................. 1-133
58568-1 ............................................................3-122

6

6-1499783-0 ...................................................3-98
6-1553342-2 ....................................................1-142
6-1553342-3 ....................................................1-145
6-1553342-4 ...................................................1-143

6-1553342-5 ....................................................1-144
6-1553343-2....................................................1-142
6-1553343-3....................................................1-145
6-1553343-4 ...................................................1-143
6-1553343-5 ...................................................1-144
6-1553346-2 ...................................................1-142
6-1553346-3 ...................................................1-145
6-1553346-4 ...................................................1-143
6-1553346-5 ...................................................1-144
6-1553347-2 ....................................................1-142
6-1553347-3 ....................................................1-145
6-1553347-4 ....................................................1-143
6-1553347-5 ....................................................1-144
6-1553348-2 ...................................................1-142
6-1553348-3 ...................................................1-145
6-1553348-4 ...................................................1-143
6-1553348-5 ...................................................1-144
6-1553349-2 ...................................................1-142
6-1553349-3 ...................................................1-145
6-1553349-4 ...................................................1-143
6-1553349-5 ...................................................1-144
6-1553387-2 ....................................................1-142
6-1553387-3 ....................................................1-145
6-1553387-4 ....................................................1-143
6-1553387-5 ....................................................1-144
6-1553389-2 ....................................................1-142
6-1553389-3....................................................1-145
6-1553389-4 ...................................................1-143
6-1553389-5....................................................1-144
6-1553390-2 ...................................................1-142
6-1553390-3 ...................................................1-145
6-1553390-4 ...................................................1-143
6-1553390-5 ...................................................1-144
6-1553397-2 ....................................................1-142
6-1553397-3 ....................................................1-145
6-1553397-4 ....................................................1-143
6-1553397-5 ....................................................1-144
6-1553399-2....................................................1-142
6-1553399-3 ...................................................1-145
6-1553399-4 ...................................................1-143
6-1553399-5 ...................................................1-144
6-1553400-2 ...................................................1-142
6-1553400-3 ...................................................1-145
6-1553400-4 ..................................................1-143
6-1553400-5 ...................................................1-144
6-1899725-0 ......................................................5-6
6-1899725-2 .......................................................5-6
6-1899725-4 ......................................................5-6
6-1899725-6.......................................................5-6
6-1899725-8 .......................................................5-6
6-1933335-0 ...................................................3-98
6-1933920-0 ...................................................3-98
6-1933921-0 ....................................................3-98

6-2111250-4...................................................... 3-62
6-2111270-4 ...................................................... 3-62
6-2111280-4 ..................................................... 3-62
6-2111290-4 ...................................................... 3-61
6-2111300-4 ...................................................... 3-61
6-2111310-4 ........................................................ 3-61
6089 2 015-01 ................................................ 3-112
608440-1 .........................................................4-20
608441-1 ...........................................................4-20 
6278807-1 ..........................................................2-13
6278807-2 .........................................................2-13
6278807-3 .........................................................2-13
6278807-4 .........................................................2-13
6278807-5 .........................................................2-13
6278807-6 .........................................................2-13
6278807-7 .........................................................2-13
6278807-8 .........................................................2-13
6278807-9 .........................................................2-13
6278808-1 ..........................................................2-13
6278808-2 ........................................................2-13
6278808-3 ........................................................2-13
6278808-4 ........................................................2-13
6278808-5 ........................................................2-13
6278808-6 ........................................................2-13
6278808-7 .........................................................2-13
6278808-8 ........................................................2-13
6278808-9 ........................................................2-13
6278810-1 ...........................................................2-13
6278810-2 ..........................................................2-13
6278810-3 ..........................................................2-13
6278810-4 .........................................................2-13
6278810-5 ..........................................................2-13
6278810-6 ..........................................................2-13
6278810-7 ..........................................................2-13
6278810-8 ..........................................................2-13
6278810-9 ..........................................................2-13
6278811-1 .............................................................2-13
6278811-2............................................................2-13
6278811-3 ...........................................................2-13
6278811-4 ...........................................................2-13
6278811-5 ...........................................................2-13
6278811-6 ...........................................................2-13
6278811-7 ............................................................2-13
6278811-8 ...........................................................2-13
6278811-9 ...........................................................2-13
6374906-1 ..........................................................1-52
6417 2 055-01 ................................................ 3-117
6417 3 006-01 ................................................ 3-117
6450 1 101-00 .................................................3-27
6450 1 101-10 .................................................3-126
6450 1 103-10 .................................................. 3-14
6450 1 107-01 .....................................3-14, 3-127
6450 2 156-20 ..................... 3-14, 3-126, 3-127

Sc9_Index_v1.indd   28

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-29

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

6450 2 157-00 .................................3-126, 3-127
6450 2 157-10 .................................................. 3-14
6450 2 157-20 ................................................ 3-14
6450 2 158-20 ..................... 3-14, 3-126, 3-127
6451 2 178-04 ................................................. 3-111
6451 2 400C-10 ..............................................3-31
6451 2 400C-20 .............................................3-31
6451 2 400C-30 .............................................3-31
6451 2 400C-40 .............................................3-31
6451 2 401C-10 ................................................3-31
6451 2 401C-20 ...............................................3-31
6451 2 401C-30 ...............................................3-31
6451 2 401C-40 ..............................................3-31
6451 2 403C-10 ...............................................3-31
6451 2 403C-20..............................................3-31
6451 2 403C-30 .............................................3-31
6451 2 403C-40 .............................................3-31
6451 2 404C-10...............................................3-31
6451 2 404C-20 .............................................3-31
6451 2 404C-30 .............................................3-31
6451 2 404C-40 .............................................3-31
6451 2 700C-10 ...............................................3-31
6451 2 700C-20 .............................................3-31
6451 2 700C-30 .............................................3-31
6451 2 700C-40 .............................................3-31
6451 2 701C-10 ................................................3-31
6451 2 701C-20 ...............................................3-31
6451 2 701C-30 ...............................................3-31
6451 2 701C-40 ...............................................3-31
6451 2 702-10 ...................................................3-31
6451 2 702-20 .................................................3-31
6451 2 702-30 .................................................3-31
6451 2 702-40 .................................................3-31
6451 2 703C-10 ...............................................3-31
6451 2 703C-20 ..............................................3-31
6451 2 703C-30 ..............................................3-31
6451 2 703C-40 ..............................................3-31
6451 2 704C-10 ...............................................3-31
6451 2 704C-20 ..............................................3-31
6451 2 704C-30 ..............................................3-31
6451 2 704C-40 .............................................3-31
6451 5 035-00 ............................................... 3-111
6457240-1 ........................................................3-99
6457240-2 ......................................................3-99
6457240-3 ......................................................3-99
6457240-4 ......................................................3-99
6457240-5 ......................................................3-99
6457567-4 .........................................................1-52
6457567-5 .........................................................1-52
6462 2 016-00 .............................................. 3-113
6462 2 096-00 ............................................. 3-112
6462 2 097-00 .............................................. 3-111
6462 2 097-20 ............................................... 3-111

6462 2 101-01 .................................................. 3-111
6468 5 060-06 ..............................................3-27
6468 5 070-00 ...............................................3-13
6468 5 300-00 .............................................3-27
6468 5 600-00 .............................................3-27
6588878-1 ..........................................................2-13
6588878-2 .........................................................2-13
6588878-3 .........................................................2-13
6588878-4 ........................................................2-13
6588878-5 .........................................................2-13
6588878-6 ........................................................2-13
6588878-7 .........................................................2-13
6588878-8.........................................................2-13
6588878-9 ........................................................2-13
6588879-1 ..........................................................2-13
6588879-2 .........................................................2-13
6588879-3 .........................................................2-13
6588879-4 ........................................................2-13
6588879-5 .........................................................2-13
6588879-6 ........................................................2-13
6588879-7 .........................................................2-13
6588879-8.........................................................2-13
6588879-9 ........................................................2-13
6619 2 046-00 ............................................  6-33
6619 2 046-01 ..............................................  6-33
6630 2 004-05 ............................................. 3-112
6631 2 003-00 ..............................................3-90
6631 2 135-00 ................................................3-90
6631 2 135-05 .................................................3-90
6631 2 135-06 .................................................3-90
6631 3 100-03 ................................................3-114
6631 3 100-22 ................................................3-90
6631 3 100-23 ................................................3-90
6631 3 100-26 ................................................3-90
6631 3 100-27 ................................................3-90
6631 3 100-28 ................................................3-90
6631 3 100-29 ................................................3-90
6631 3 100-30 ................................................3-90
6631 3 102-01/09 .........................................3-114
6631 3 102-02/03.........................................3-114
6631 3 102-04/06 ........................................3-114
6631 3 102-05/07 .........................................3-114
6631 3 102-08 ................................................3-114
6631 3 105-05 ................................................3-114
6631 3 105-06 ................................................3-114
6631 3 105-07 ................................................3-114
6631 3 105-08 ................................................3-114
6631 3 106-XX ................................................3-114
6636 1 596-06 ................................................3-27
6636 1 596-46 ................................................3-27
6636 1 598-06 .................................................3-13
6636 1 598-46 .................................................3-13
6642 1 115-04 .................................................. 3-91

6642 1 115-05 ................................................... 3-91
6642 1 315-04 ................................................. 3-91
6642 1 315-05 ................................................. 3-91
6645 2 127 ........................................................ 3-111
6645 2 251-XX ............................................... 3-93
6645 2 254-01 ............................................... 3-93
6645 2 264-XX ............................................. 3-93
6645 2 265-XX .............................................. 3-93
6645 2 266-XX ............................................. 3-93
6645 2 267-XX .............................................. 3-93
6645 2 268-XX ............................................. 3-93
6645-2-805 ................................................... 3-127
6645-2-825 .................................................... 3-127
6646 3 001-01 ................................................ 3-111
6648 2 000-XX ............................................ 3-29
6648 2 005-XX ............................................. 3-29
6648 2 900...................................................... 3-111
6648 2 901 ....................................................... 3-111
6652 2 039-06 ............................................  6-32
6652 2 039-11 ...............................................  6-32
6652 2 039-21 ..............................................  6-32
6652 2 040-06 ...........................................  6-33
6652 2 040-11 ..............................................  6-33
6652 2 040-21 .............................................  6-33
6652 2 067-19 .............................................   6-29
6652 2 068-19 ............................................   6-29
6652 2 069-19 ............................................   6-29
6652 2 069-23 ...........................................   6-29
6652 2 070-19 ............................................   6-29
6652 2 070-23 ...........................................   6-29
6652 2 080-19 ............................................   6-29
6652 2 080-23 ...........................................   6-29
6652 2 081-19 ..............................................   6-29
6652 2 081-23 .............................................   6-29
6652 2 082-19 .............................................   6-29
6652 2 083-19 ............................................   6-29
6652 2 100-00 ...........................................   6-34
6652 2 101-00 .............................................   6-34
6652 2 113-00 .............................................   6-34
6652 2 114-00 .............................................   6-34
6653 1 679-24 ................................................ 3-22
6653 1 679-48................................................ 3-22
6654 2 350-06/1 .........................................  6-31
6654 2 350-11/1 ............................................  6-31
6654 2 350-21/2 ..........................................  6-31
6655 2 400-03 ...........................................  6-32
6655 2 450-06/1 .........................................  6-31
6655 2 450-11/1 ............................................  6-31
6655 2 450-21/2 ..........................................  6-31
6655 2 450-31/3 .........................................  6-31
6657 2 005-03 ............................................  6-28
6657 2 005-04 ...........................................  6-28
6657 2 005-19/03 ....................................  6-30

Sc9_Index_v1.indd   29

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-30

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

6657 2 005-19/04 ....................................  6-30
6657 2 005-23/03 ...................................  6-30
6657 2 005-23/04 ...................................  6-30
6657 2 005-35/04 ...................................  6-30
6657 2 005-35/05 ...................................  6-30
6657 2 005-35/06 ...................................  6-30
6657 2 005-43 ............................................  6-28
6657 2 005-44............................................  6-28
6657 2 006-06/02 ..................................  6-30
6657 2 006-09/03 ..................................  6-30
6657 2 165-00 .............................................  6-27
6657 2 165-40 .............................................  6-27
6693949-1..........................................................2-13
6693949-2 ........................................................2-13
6693949-3 ........................................................2-13
6693949-4 ........................................................2-13
6693949-5 ........................................................2-13
6693949-6 ........................................................2-13
6693949-7 ........................................................2-13
6693949-8 ........................................................2-13
6693949-9 ........................................................2-13
6693951-1 ...........................................................2-13
6693951-2 ..........................................................2-13
6693951-3 ..........................................................2-13
6693951-4..........................................................2-13
6693951-5 ..........................................................2-13
6693951-6 ..........................................................2-13
6693951-7 ..........................................................2-13
6693951-8 ..........................................................2-13
6693951-9 ..........................................................2-13
6754252-1...........................................................2-13
6754252-2 .........................................................2-13
6754252-3 .........................................................2-13
6754252-4 .........................................................2-13
6754252-5 .........................................................2-13
6754252-6 .........................................................2-13
6754252-7 .........................................................2-13
6754252-8 .........................................................2-13
6754252-9 .........................................................2-13
6754285-2 .........................................................2-14
6754285-3 .........................................................2-14
6754285-4 .........................................................2-14
6754285-5 .........................................................2-14
6754285-6 .........................................................2-14
6754285-7 .........................................................2-14
6754285-8 .........................................................2-14
6754285-9 .........................................................2-14
6754286-2 .........................................................2-14
6754286-3 .........................................................2-14
6754286-4.........................................................2-14
6754286-5 .........................................................2-14
6754286-6 .........................................................2-14
6754286-7 .........................................................2-14

6754286-8 .........................................................2-14
6754286-9 .........................................................2-14
6754287-2 .........................................................2-14
6754287-3 .........................................................2-14
6754287-4 .........................................................2-14
6754287-5 .........................................................2-14
6754287-6 .........................................................2-14
6754287-7 .........................................................2-14
6754287-8 .........................................................2-14
6754287-9 .........................................................2-14
6754288-2 .........................................................2-14
6754288-3 .........................................................2-14
6754288-4.........................................................2-14
6754288-5 .........................................................2-14
6754288-6 .........................................................2-14
6754288-7 .........................................................2-14
6754288-8 .........................................................2-14
6754288-9 .........................................................2-14
6828819-2 ..........................................................2-14
6828819-3 ..........................................................2-14
6828819-4 .........................................................2-14
6828819-5 ..........................................................2-14
6828819-6 ..........................................................2-14
6828819-7 ..........................................................2-14
6828819-8 ..........................................................2-14
6828819-9 ..........................................................2-14
6830 1 835- .................................................... 3-127

7

7-1499783-0 ...................................................3-98
7-1553307-3 ....................................................1-145
7-1553308-3 ....................................................1-145
7-1553311-3 .......................................................1-145
7-1553312-3 .....................................................1-145
7-1553315-3 .....................................................1-145
7-1553316-3 .....................................................1-145
7-1553406-3 ......................................................1-21
7-1553407-3 .......................................................1-21
7-1553408-3 ......................................................1-21
7-1553409-3 ......................................................1-21
7-1553410-3 ........................................................1-21
7-1553411-3 .........................................................1-21
7-1553412-3 ........................................................1-21
7-1553413-3 ........................................................1-21
7-1553414-3 ........................................................1-21
7-1553415-3 ........................................................1-21
7-1553416-3 ........................................... 1-21, 1-145
7-1553417-3 ........................................... 1-21, 1-145
7-1553418-3 ........................................... 1-21, 1-145
7-1553419-3 ........................................... 1-21, 1-145
7-1553420-3..................................................... 1-115
7-1777117-7 .......................................................1-144
7-1777121-7 .......................................................1-144

7-1899725-0 .......................................................5-6
7-1899725-2 .......................................................5-6
7-1899725-4 .......................................................5-6
7-1899725-6 .......................................................5-6
7-1899725-8 .......................................................5-6
7-1933335-0....................................................3-98
7-1933920-0 ...................................................3-98
7-1933921-0 .....................................................3-98
7-2111250-5 ...................................................... 3-62
7-2111270-5 ...................................................... 3-62
7-2111280-5 ...................................................... 3-62
7-2111290-5 ....................................................... 3-61
7-2111300-5 ....................................................... 3-61
7-2111310-5 ........................................................ 3-61
790163-1 ............................................................3-119
790163-2 ..........................................................3-119
790163-5 ..........................................................3-119
790163-6 ..........................................................3-119
790163-9 ..........................................................3-119

8

8-1499783-0 ...................................................3-98
8-1899725-0 ......................................................5-6
8-1899725-2 .......................................................5-6
8-1899725-4 ......................................................5-6
8-1899725-6 .......................................................5-6
8-1933335-0 ...................................................3-98
8-1933920-0 ...................................................3-98
8-1933921-0 ....................................................3-98
853400-1 .........................................................3-120
853400-7 ........................................................3-120
853400-8 .......................................................3-120
856727-1............................................................ 3-121

9

9-336513-1........................................................ 3-25
9-336513-2 ...................................................... 3-25
9-336513-3 ...................................................... 3-25
9-336513-4 ...................................................... 3-25
9-336513-5 ...................................................... 3-25
9-336513-6 ...................................................... 3-25
9-336513-7 ...................................................... 3-25
9-336513-8 ...................................................... 3-25
9-336513-9 ...................................................... 3-25
9-737893-1 ....................................................... 3-25
9-737893-2...................................................... 3-25
9-737893-3 ..................................................... 3-25
9-737893-4 ..................................................... 3-25
9-737893-5 ..................................................... 3-25
9-737893-6 ..................................................... 3-25
9-737893-7 ...................................................... 3-25
9-737893-8 ..................................................... 3-25
9-737893-9 ..................................................... 3-25

Sc9_Index_v1.indd   30

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-31

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

9-1499783-0 ...................................................3-98
9-1933335-0 ...................................................3-98
9-1933920-0 ...................................................3-98
9-1933921-0 ....................................................3-98
9-2111250-5 ...................................................... 3-62
9-2111251-5 ....................................................... 3-62
9-2111252-5 ...................................................... 3-62
9-2111270-5 ...................................................... 3-62
9-2111271-5 ........................................................ 3-62
9-2111272-5....................................................... 3-62
9-2111280-5 ...................................................... 3-62
9-2111281-5 ....................................................... 3-62
9-2111282-5 ...................................................... 3-62
9-2111290-5 ....................................................... 3-61
9-2111291-5 ........................................................ 3-61
9-2111292-5 ....................................................... 3-61
9-2111300-5 ...................................................... 3-61
9-2111301-5 ........................................................ 3-61
9-2111302-5 ....................................................... 3-61
9-2111310-5 ........................................................ 3-61
9-2111311-5 .......................................................... 3-61
9-2111312-5 ........................................................ 3-61
9-2111653-1 .......................................................3-69
9-2111673-1 ........................................................3-69

A

ADCCMHIBS-3U ..........................................1-107
ADCLS-CL4A ................................................1-138
ADCLS-CL10A ..............................................1-138
ADCLS-CL12A ...............................................1-138
ADCLS-CL24A ..............................................1-138
ADCLS-NGF144LCAR ...............................1-138
ADCLS-NGF144SCAL ...............................1-138
ADCLS-NGF192LCAL ................................1-138
ADCLS-NGF192LCAR ...............................1-138
ADCLS-TFP1RUA .........................................1-138
ADCLS-TFP2RUA ........................................1-138
ADCLS-TFP5RUA........................................1-138
ADCPP16KSRJRJ..........................................3-79
ADCPP24RJ5E-S ..........................................3-79
ADCPP24RJ6-S.............................................3-79
ADCPP32KSRJRJ ........................................3-79
ADCPP24505 .................................................3-79
ADCPP24606 .................................................3-79
ADCPP48505 .................................................3-79
ADCPP48606 ................................................3-79
ADCRACKBLK73 .......................................... 5-14

F

FGSB-ACC063 ..............................................  6-11
FGSB-ASRI-5F ..............................................  6-8
FGSB-ASRI-10F ............................................  6-8
FGSB-ASRI-15F .............................................  6-8

FGSB-ISLAND-H/F ...................................  6-14
FGSB-JUNC-G ..............................................  6-6
FGSB-KDH2-C ..............................................   6-5
FGSB-KT03-A ...............................................  6-8
FGSB-KT03-A1 ..............................................  6-8
FGSB-KT03-C ...............................................   6-5
FGSB-KTW1-C ...............................................  6-11
FGSB-KTW1-CA ...........................................  6-11
FGSB-KTW1-E ...............................................  6-11
FGSB-KTW2-D .............................................  6-11
FGSB-KTW4-C .............................................  6-11
FGSB-KTW4-E .............................................  6-11
FGSB-MCDS-AB .................................  6-7, 6-9
FGSB-MCDS-EX-AB..........................  6-7, 6-9
FGSB-MD4A-C .............................................  6-4
FGSB-MD4E-A ...............................................  6-7
FGSB-MD4E-B ..............................................  6-9
FGSB-MD4E-F ............................................   6-10
FGSB-MD4E-G ..............................................  6-6
FGSB-MD4E-H .............................................  6-14
FGSB-MD9A-C..............................................  6-4
FGSB-MD9E-A ...............................................  6-7
FGSB-MD9E-B ..............................................  6-9
FGSB-MD9E-F ............................................   6-10
FGSB-MD9E-G ..............................................  6-6
FGSB-MDRT-F ............................................   6-10
FGSB-MDSA-AB ...........................................  6-7
FGSB-MDSA-AC ..........................................  6-4
FGSB-MDSA-F2B ......................................   6-10
FGSB-MDSA-FB .........................................   6-10
FGSB-MDSA-GA ..........................................  6-6
FGSB-MDSA-GB ..........................................  6-6
FGSB-MDSP-A ...............................................  6-7
FGSB-MDSP-B ..............................................  6-9
FGSB-MDSP-C ..............................................   6-5
FGSB-MDSP-EX-A .......................................  6-7
FGSB-MDSP-EX-B ......................................  6-9
FGSB-MDSP-F ............................................   6-10
FGSB-MDSP-G ..............................................  6-6
FGSB-MEX1-C-5F ..............................   6-5, 6-8
FGSB-MEXC-E-A .........................................  6-4
FGSB-MEXC-E-A/B/F...............................  6-4
FGSB-MEXC-E-B .........................................  6-4
FGSB-MEXC-E-F..........................................  6-4
FGSB-MEXP-A/B/F ...................................  6-4
FGSB-MEXP-E-A/B/F...............................  6-4
FGSB-MEXP-LP-A/B/F ............................  6-4
FGSB-MEXP-LP-G ......................................  6-6
FGSB-MFAW-A ..............................................  6-7
FGSB-MFAW-B .............................................  6-9
FGSB-MFAW-H ............................................  6-13
FGSB-MFTY-5F ...........................................  6-12
FGSB-MFTY-10F .........................................  6-12

FGSB-MFTY-15F ..........................................  6-12
FGSB-MFTY-200F .....................................  6-12
FGSB-MH4A-C..............................................  6-4
FGSB-MH4E-A ...............................................  6-7
FGSB-MH4E-B ..............................................  6-9
FGSB-MH4E-F ............................................   6-10
FGSB-MH4E-G ..............................................  6-6
FGSB-MH4E-H .............................................  6-14
FGSB-MH9A-C ..............................................  6-4
FGSB-MH9E-A ...............................................  6-7
FGSB-MH9E-B ..............................................  6-9
FGSB-MH9E-F ............................................   6-10
FGSB-MH9E-G ..............................................  6-6
FGSB-MHIS-A .................................................  6-7
FGSB-MHIS-B ................................................  6-9
FGSB-MHIS-F ..............................................   6-10
FGSB-MHIS-F/H ..........................................  6-14
FGSB-MHRT-A ...............................................  6-7
FGSB-MHRT-B ..............................................  6-9
FGSB-MHRT-F.............................................   6-10
FGSB-MHRT-F/B .......................................   6-10
FGSB-MHRT-G ..............................................  6-6
FGSB-MHTA-C ..............................................  6-4
FGSB-MHXP-A ...............................................  6-7
FGSB-MHXP-B ..............................................  6-9
FGSB-MHXP-B/F.......................................   6-10
FGSB-MHXP-C ..............................................  6-4
FGSB-MHXP-F ............................................   6-10
FGSB-MHXP-G .............................................  6-6
FGSB-MHXP-H.............................................  6-14
FGSB-MIDY-5F .............................................  6-12
FGSB-MIDY-10F ...........................................  6-12
FGSB-MIDY-15F ...........................................  6-12
FGSB-MJWR-A.............................................  6-8
FGSB-MJWR-C .............................................  6-4
FGSB-MJWR-D ............................................  6-11
FGSB-MLDY-100F ......................................  6-12
FGSB-MLDY-150F .......................................  6-12
FGSB-MLDY-200F .....................................  6-12
FGSB-MLDY-250F .....................................  6-12
FGSB-MSDS-C ..............................................   6-5
FGSB-MSHA-C ..............................................  6-4
FGSB-MSHC-A ...............................................  6-7
FGSB-MSHC-B ..............................................  6-9
FGSB-MSHC-C ..............................................  6-11
FGSB-MSHC-D..............................................  6-11
FGSB-MSHS-A ...............................................  6-7
FGSB-MSHS-B ..............................................  6-9
FGSB-MSHS-C ..............................................  6-11
FGSB-MSHS-CA ...........................................  6-11
FGSB-MSHS-D ..............................................  6-11
FGSB-MSHS-F.............................................   6-10
FGSB-MSHS-G ..............................................  6-6

Sc9_Index_v1.indd   31

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-32

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

FGSB-MSHS-H .............................................  6-13
FGSB-MSNC-B/G ........................................  6-6
FGSB-MSNC-F ............................................   6-10
FGSB-MTRM-A .............................................  6-8
FGSB-MTRM-B .............................................  6-9
FGSB-MTRM-F ............................................   6-10
FGSB-MTRM-G .............................................  6-6
FGSB-MU4A-C..............................................  6-4
FGSB-MU4E-A ...............................................  6-7
FGSB-MU4E-B ..............................................  6-9
FGSB-MU4E-F ............................................   6-10
FGSB-MU4E-G ..............................................  6-6
FGSB-MU9A-C ..............................................  6-4
FGSB-MU9E-A ...............................................  6-7
FGSB-MVAR-A...............................................  6-7
FGSB-MVAR-B ..............................................  6-9
FGSB-MVAR-F ............................................   6-10
FGSB-SD4E-A ................................................  6-7
FGSB-SD4E-B ...............................................  6-9
FGSB-SD9E-A ................................................  6-7
FGSB-SD9E-B ...............................................  6-9
FGSB-SDSA-AB ............................................  6-7
FGSB-SH4E-A ................................................  6-7
FGSB-SH4E-B ...............................................  6-9
FGSB-SH9E-A ................................................  6-7
FGSB-SH9E-B ...............................................  6-9
FGSB-SHRT-A ................................................  6-7
FGSB-SHRT-B ...............................................  6-9
FGSB-SHXP-A ................................................  6-7
FGSB-SHXP-B ...............................................  6-9
FGS-BTBL-C...................................................   6-5
FGS-BTBS-C ..................................................   6-5
FGS-HAEJ-C ..................................................   6-5
FGS-HASB-1/2-36 .......................................  6-8
FGS-HASB-1/2-48 .......................................  6-8
FGS-HASB-5/8-36 ......................................  6-8
FGS-HASB-5/8-48......................................  6-8
FGS-HASK-C ..................................................   6-5
FGS-HCBL-12 .................................................  6-8
FGS-HCBL-15 .................................................  6-8
FGS-HDCB-C .................................................   6-5
FGS-HDGR ......................................................  6-8
FGS-HDSI-AB ................................................  6-8
FGS-HETP-H-5/8 ........................................  6-15
FGS-HETR-1/2 ...............................................  6-8
FGS-HETR-5/8 ..............................................  6-8
FGS-HETR-5/8-A ........................................  6-8
FGS-HETR-F-5/8 .........................................  6-11
FGS-HFCK-1/2 ...............................................  6-8
FGS-HFCK-5/8 ..............................................  6-8
FGS-HFRR-10 ...............................................  6-12
FGS-HHEC-10 ...............................................  6-12
FGS-HHGK .....................................................  6-12

FGS-HIFC-A .....................................................  6-7
FGS-HIFC-B ....................................................  6-9
FGS-HIFC-F ..................................................   6-10
FGS-HLBK .......................................................  6-8
FGS-HLDR-5/8 ...................................   6-5, 6-8
FGS-HLR2-C ..................................................   6-5
FGS-HMEC-A ..................................................  6-7
FGS-HMEC-B .................................................  6-9
FGS-HMEC-C .................................................  6-4
FGS-HMEC-F ...............................................   6-10
FGS-HMEC-G .................................................  6-6
FGS-HMEC-H ................................................  6-14
FGS-HNLR-AB ..............................................  6-8
FGS-HNLR-F ..................................................  6-11
FGS-HNTP-F-5/8.........................................  6-11
FGS-HNTP-H-5/8 .......................................  6-15
FGS-HNTR-1/2...............................................  6-8
FGS-HNTR-5/8 .............................................  6-8
FGS-HNTR-5/8-A ........................................  6-8
FGS-HNTR-F-5/8 ........................................  6-11
FGS-HNTS-5/8 .............................................  6-8
FGS-HNTS-5/8-LP ......................................  6-8
FGS-HNTS-F-5/8 .........................................  6-11
FGS-HNTS-F-5/8-LP .................................  6-11
FGS-HQKK .....................................................  6-12
FGS-HSHS-C ..................................................   6-5
FGS-HTHR-5/8-12 .............................   6-5, 6-8
FGS-HTHR-5/8-30 .....................................  6-8
FGS-HTHR-5/8-72 ......................................  6-8
FGS-HTR2-1/2 ...............................................   6-5
FGS-HTR2-5/8 ..............................................   6-5
FGS-HTUB-1/2 ...............................................  6-8
FGS-HTUB-2-AB ..........................................   6-5
FGS-HTUB-5/8 .............................................  6-8
FGS-HUFB-C .................................................   6-5
FGS-HVHG .....................................................  6-12
FGS-HWMB-C ...............................................  6-11
FGS-HWMB-D ...............................................  6-11
FGS-KQKB .....................................................  6-12
FGS-KT09 ......................................................  6-12
FGS-MH4E-H-VS ........................................  6-15
FGS-MHIS-JIG-A/B/F ......................  6-7, 6-9
FGS-MHIS-JIG-A/B/F1 ............................   6-10
FGS-MHRT-H ................................................  6-14
FGS-MHRT-H/F ...........................................  6-14
FGS-MHRT-H/F-VS ...................................  6-15
FGS-MHXP-F/H-VS ...................................  6-15
FGS-MHXP-H-VS ........................................  6-15
FGS-MKIT-ABF ............................................  6-12
FGS-MTRM-H ...............................................  6-14
FGSO-MDSA-HF .........................................  6-14
FGSO-MHIS-A/H.........................................  6-14
FGSO-MHIS-B/H .........................................  6-14

FGSO-MHXP-F/H .......................................  6-14
FGSO-MU4E-H ............................................  6-14
FL2-6P4SC605R .......................................... 1-98
FL2-6P6JC605R ........................................... 1-98
FL2-6P7SC605R ........................................... 1-98
FL2-6P8SC605R........................................... 1-98
FL2-6P9JC605R ........................................... 1-98
FL2-6PBLNK ....................................................1-97
FL2-6PDJC605R .......................................... 1-98
FL2-6PMMDSC ...............................................1-97
FL2-6PMMDSC-A ..........................................1-97
FL2-6PMMLC ...................................................1-97
FL2-6PMMLC-A ..............................................1-97
FL2-6PMMSC ...................................................1-97
FL2-6PMMSC-A .............................................1-97
FL2-6PMMST ...................................................1-97
FL2-6PSMDSC ................................................1-97
FL2-6PSMLC ....................................................1-97
FL2-6PSMSC ....................................................1-97
FL2-6PSMST ....................................................1-97
FL2-12RPNL-B ................................................ 1-95
FL2-12TS350-B ..............................................1-94
FL2-24RPNL-B............................................... 1-95
FL2-24TS525-B .............................................1-94
FL2-36RPNL-B .............................................. 1-95
FL2-48RPNL-B .............................................. 1-95
FL2-48SPNL2-B ............................................ 1-96
FL2-48TS875-B .............................................1-94
FL2-72RPNL-B ............................................... 1-95
FL2-72TS140-B ..............................................1-94
FL2-96RPNL-B .............................................. 1-95
FL2-96SPNL2-B ............................................ 1-96
FL2-144SPNL2-B .......................................... 1-96
FL2-ACC007 ................................................... 1-96
FP 1375351 ..................................................... 3-109
FP 1375352 .................................................... 3-109
FP 1375353 .................................................... 3-109
FST-DRS12-MT ..............................................1-102
FST-DRS24-NT .............................................1-102
FST-DV-HS ........................................................1-55
FST-DV-MT .......................................................1-55
FST-HS-48 ........................................................ 1-63

M

MPA-NC6CJ50050F-NN.......................... 1-114
MPA-NC6CJ50100F-NN ........................... 1-114
MPA-NC6CJ50200F-NN .......................... 1-114
MPA-NC6CJ50300F-NN.......................... 1-114
MPA-NCNC430 ................................................1-4
MPA-NCNC440 ................................................1-4
MPA-NCNC450 ................................................1-4
MPA-NCNC730 .................................................1-4
MPA-NCNC740 .................................................1-4

Sc9_Index_v1.indd   32

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-33

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

MPA-NCNC750 .................................................1-4
MPA-NCNC930 ................................................1-4
MPA-NCNC940 ................................................1-4
MPA-NCNC950 ................................................1-4
MPA-NCNCD10 ................................................. 1-3
MPA-NCNCD20 ................................................ 1-3
MPA-NCNCD30 ........................................1-3, 1-4
MPA-NCNCD40 .......................................1-3, 1-4
MPA-NCNCD50 ........................................1-3, 1-4
MPA-NCNCJ10 .................................................. 1-3
MPA-NCNCJ20 ................................................. 1-3
MPA-NCNCJ30 ................................................. 1-3
MPA-NCNCJ40 ................................................ 1-3
MPA-NCNCJ50 ................................................. 1-3
MPA-NCNCJ50100F-NN .......................... 1-114
MPA-NCNCJ50200F-NN ......................... 1-114
MPA-NCNCJ50300F-NN ......................... 1-114
MPA-NCNCJ50305M-NN ........................ 1-114
MPA-NCNCJ50305M-SS .......................... 1-114
MPA-NCNCJ50400F-NN ......................... 1-114
MPA-NCNCJ50500F-NN ......................... 1-114
MPA-NCNCJ50600F-NN ......................... 1-114
MPA-NCNCJ50750F-NN .......................... 1-114
MPA-NCNCZ30 ................................................1-4
MPA-NCNCZ40 ................................................1-4
MPA-NCNCZ50 ................................................1-4
MPA-NCNCZ50100F-SS ........................... 1-114
MPA-NCNCZ50200F-SS .......................... 1-114
MPA-NCNCZ50300F-SS .......................... 1-114
MPA-NCNCZ50400F-SS ......................... 1-114
MPA-NCNCZ50500F-SS .......................... 1-114
MPA-NCNCZ50600F-SS ......................... 1-114
MPA-NCNCZ50750F-SS .......................... 1-114
MPA-NCSCJ50050F-NN.......................... 1-114
MPA-NCSCJ50100F-NN ........................... 1-114
MPA-NCSCJ50200F-NN .......................... 1-114
MPA-NCSCJ50300F-NN .......................... 1-114
MPA-NCTCJ50050F-NN .......................... 1-114
MPA-NCTCJ50100F-NN ........................... 1-114
MPA-NCTCJ50200F-NN .......................... 1-114
MPA-NCTCJ50300F-NN .......................... 1-114
MPA-PCLCJ30003M-18 ............................... 1-5
MPA-PCLCJ30004M-18 ............................... 1-5
MPA-PCLCJ30005M-18 ............................... 1-5
MPA-PCLCJ40003M-18 ............................... 1-5
MPA-PCLCJ40004M-18 ............................... 1-5
MPA-PCLCJ40005M-18 ............................... 1-5
MPA-PCLCJ50003M-18 ............................... 1-5
MPA-PCLCJ50004M-18 ............................... 1-5
MPA-PCLCJ50005M-18 ............................... 1-5
MPA-PCSCJ30003M-18 ............................... 1-5
MPA-PCSCJ30004M-18 ............................... 1-5
MPA-PCSCJ30005M-18 ............................... 1-5

MPA-PCSCJ40003M-18 ............................... 1-5
MPA-PCSCJ40004M-18............................... 1-5
MPA-PCSCJ40005M-18 ............................... 1-5
MPA-PCSCJ50003M-18 ............................... 1-5
MPA-PCSCJ50004M-18 ............................... 1-5
MPA-PCSCJ50005M-18 ............................... 1-5
MPC-CzCzD10xxxF-SS ...............................2-15
MPC-CzCzD20xxxF-SS ..............................2-15
MPC-CzCzD30xxxF-SS..............................2-15
MPC-CzCzD40xxxF-SS .............................2-15
MPC-CzCzJ10xxxF-NN ..............................2-15
MPC-CzCzJ20xxxF-NN .............................2-15
MPC-CzCzJ30xxxF-NN .............................2-15
MPC-CzCzJ40xxxF-NN .............................2-15
MX6-BSPL-1440-U7 ....................................1-101
MX6-SPLIFCCLMP ......................................1-102

N

NGF-ACCCLMP04 ....................................... 1-88
NGF-ACCCLMP08 ....................................... 1-88
NGF-ACCIOSP30X24 ...................... 1-85, 1-87
NGF-ACCISOPEG24 ..............1-76, 1-85, 1-87
NGF-ACCISOPFS12X24..............................1-75
NGFB-ACCEGD007 ...............1-76, 1-85, 1-87
NGFB-ACCFOTSB ........................................1-75
NGFB-ACCRCMSLD ................................... 1-83
NGFB-ACCRCMSLU ................................... 1-83
NGFB-ACCRCMSRD ................................... 1-83
NGFB-ACCRCMSRU ................................... 1-83
NGFB-MDF7A100-30 .................................1-74
NGFB-MDF7A144-30 ............1-74, 1-85, 1-87
NGFB-MPML0C112 ............................ 1-85, 1-87
NGFB-MPML0C612 ........................... 1-85, 1-87
NGFB-MPML0K512 ........................... 1-85, 1-87
NGFB-MPMR0C112 ........................... 1-85, 1-87
NGFB-MPMR0C612 .......................... 1-85, 1-87
NGFB-MPMR0K512 .......................... 1-85, 1-87
NGFB-TB1MLD7...............................................1-81
NGFB-TB1MLD9 ..............................................1-81
NGFB-TB1MLDT ..............................................1-81
NGFB-TB1MLU7 ...............................................1-81
NGFB-TB1MLU9 ..............................................1-81
NGFB-TB1MLUT ..............................................1-81
NGFB-TB1MRD7 ..............................................1-81
NGFB-TB1MRD9 ..............................................1-81
NGFB-TB1MRDT ..............................................1-81
NGFB-TB1MRU7 ..............................................1-81
NGFB-TB1MRU9 ..............................................1-81
NGFB-TB1MRUT ..............................................1-81
NGFB-TB4MLDC ............................................1-81
NGFB-TB4MLDK .................................1-81, 1-82
NGFB-TB4MLDP .............................................1-81
NGFB-TB4MLUC.............................................1-81

NGFB-TB4MLUK ..................................1-81, 1-82
NGFB-TB4MLUP .............................................1-81
NGFB-TB4MRDC ............................................1-81
NGFB-TB4MRDK .................................1-81, 1-82
NGFB-TB4MRDP ............................................1-81
NGFB-TB4MRUC ............................................1-81
NGFB-TB4MRUK .................................1-81, 1-82
NGFB-TB4MRUP ............................................1-81
NGFB-TB4QLDC ...........................................1-82
NGFB-TB4QLDP ............................................1-82
NGFB-TB4QLUC ............................................1-82
NGFB-TB4QLUP ............................................1-82
NGFB-TB4QRDC ...........................................1-82
NGFB-TB4QRDP ...........................................1-82
NGFB-TB4QRUC ...........................................1-82
NGFB-TB4QRUP ...........................................1-82
NGF-SAP70K00 ........................................... 1-84
NGF-SAP90K00 ........................................... 1-84
NGF-SAPC0J00 ........................................... 1-84
NGF-SAPC0K00 .......................................... 1-84
NGF-SAPK0J00 ........................................... 1-84
NGF-SAPK0K00 .......................................... 1-84
NGF-SAPP0J00 ........................................... 1-84
NGF-SAPP0K00 ........................................... 1-84
NGF-SAPT0K00 ........................................... 1-84

O

OCB-ACC200-PKLT3 ................................1-109
ODT-SM12J00D0619A ...............................1-110
ODT-SM12J00D0929A ..............................1-110
ODT-SM12J00D1229A ................................1-110
ODT-SM12J00D1529A ................................1-110
OLH-MK072J00M0M000 ......................1-108
OLH-MK072J00M0MKBA ......................1-108
OLH-MK072J00M0MKCA ......................1-108
OLH-MK072J00M0MKEA ......................1-108
OLH-MM288J00M0M000 .....................1-108
OLH-MM288J00M0MKBB .....................1-108
OLH-MM288J00M0MKCB .....................1-108
OLH-MM288J00M0MKEB .....................1-108
OLH-MM 432J00M0M000 ....................1-108
OLH-MN432J00M0MKBB .....................1-108
OLH-MN432J00M0MKCB ......................1-108
OLH-MN432J00M0MKEB ......................1-108
OLR-SJ12J00D1002A ................................1-110
OLR-SJ12J00D2002A ...............................1-110
OLR-SJ12J00D3002A ...............................1-110
OLR-SJ24J00D1002A ...............................1-110
OLR-SJ24J00D2002A ..............................1-110
OLR-SJ24J00D3002A ..............................1-110
OLS-MPP1G66 ...............................................1-109
OLS-MPP12A66 ...............................................1-111
OLS-MPP10866 ..................................1-109, 1-111

Sc9_Index_v1.indd   33

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-34

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

OLS-MPP11666 ....................................1-109, 1-111
OLS-MPP13266 ...................................1-109, 1-111
OPS-FMTSP-AJJ01 .....................................1-109
OPS-FMTSP-GJJ01 .....................................1-109
OPS-MPPACCRMPNL ...............................1-109
OPS-MPPRACKMT24 ................................1-109
OPS-MPPRACKMTCM ..............................1-109
OSB-SBJ032A10000 ...................................1-111
OSB -SBJ032G10000 ..................................1-111
OSB-SBJ232A10000....................................1-111
OSB -SBJ232G10000 ..................................1-111
OSB-SBJ032000000 ..................................1-111
OSB-SBJ232000000 ..................................1-111
OTN-0LSSBKT-1 ........................................... 1-123
OTN-OLSSBKT-2 ......................................... 1-123

P

PAT-6C6C-PS0G003M .............................. 1-113
PAT-6C6C-PS0G008M .............................. 1-113
PAT-6C6C-PS0G016M ............................... 1-113
PAT-6C6C-PS0G023M .............................. 1-113
PAT-6C6C-PS0G031M................................ 1-113
PAT-6C6C-PS0G038M .............................. 1-113
PAT-6C6C-PS0G046M .............................. 1-113
PAT-6C6C-PSIG003M .................................1-112
PAT-6C6C-PSIG008M .................................1-112
PAT-6C6C-PSIG016M ..................................1-112
PAT-6C6C-PSIG023M .................................1-112
PAT-6C6C-PSIG031M...................................1-112
PAT-6C6C-PSIG038M .................................1-112
PAT-6C6C-PSIG046M .................................1-112
PAT-LC8z-R10CxxxM ....................................2-8
PAT-LC8z-R20CxxxM ...................................2-8
PAT-LC8z-R30CxxxM...................................2-8
PAT-LC8z-R40CxxxM ..................................2-8
PAT-LC9z-R10BxxxM ....................................2-11
PAT-LC9z-R20BxxxM ...................................2-11
PAT-LC9z-R30BxxxM ..................................2-11
PAT-LC9z-R40BxxxM ..................................2-11
PAT-LCLC-P10C ...............................................1-16
PAT-LCLC-P20C ..............................................1-16
PAT-LCLC-P30C ..............................................1-16
PAT-LCLC-P40C .............................................1-16
PAT-LCLC-PS0C..............................................1-16
PAT-LCLC-R20C001M ...............................1-142
PAT-LCLC-R20C002M ..............................1-142
PAT-LCLC-R20C003M ..............................1-142
PAT-LCLC-R20C005M..............................1-142
PAT-LCLC-R30C001M ...............................1-143
PAT-LCLC-R30C002M ..............................1-143
PAT-LCLC-R30C003M .............................1-143
PAT-LCLC-R30C005M .............................1-143
PAT-LCLC-RS0C001M ..................1-144, 1-145

PAT-LCMC-P10B ..............................................1-16
PAT-LCMC-P20B.............................................1-16
PAT-LCMC-P30B ............................................1-16
PAT-LCMC-PS0B ............................................1-16
PAT-LCSC-P10C ...............................................1-16
PAT-LCSC-P20C .............................................1-16
PAT-LCSC-P30C .............................................1-16
PAT-LCSC-PS0C .............................................1-16
PAT-LCSC-R20C001M...............................1-142
PAT-LCSC-R20C002M .............................1-142
PAT-LCSC-R20C003M .............................1-142
PAT-LCSC-R20C005M .............................1-142
PAT-LCSC-R30C001M ..............................1-143
PAT-LCSC-R30C002M .............................1-143
PAT-LCSC-R30C003M .............................1-143
PAT-LCSC-R30C005M .............................1-143
PAT-LCSC-RS0C001M .................1-144, 1-145
PAT-LCSC-RS0C002M ................1-144, 1-145
PAT-LCSC-RS0C003M ................1-144, 1-145
PAT-LCSC-RS0C005M ................1-144, 1-145
PAT-LCTC-P10C ...............................................1-16
PAT-LCTC-P20C ..............................................1-16
PAT-LCTC-P30C ..............................................1-16
PAT-LCTC-PS0C .............................................1-16
PAT-MC8z-R10BxxxM ..................................2-8
PAT-MC8z-R20BxxxM .................................2-8
PAT-MC8z-R30BxxxM .................................2-8
PAT-MC8z-R40BxxM....................................2-8
PAT-MC9z-R10BxxxM ..................................2-11
PAT-MC9z-R20BxxxM .................................2-11
PAT-MC9z-R30BxxxM .................................2-11
PAT-MC9z-R40BxxxM .................................2-11
PAT-SC6C-PS0G003M .............................. 1-113
PAT-SC6C-PS0G008M .............................. 1-113
PAT-SC6C-PS0G016M ............................... 1-113
PAT-SC6C-PS0G023M .............................. 1-113
PAT-SC6C-PS0G031M................................ 1-113
PAT-SC6C-PS0G038M .............................. 1-113
PAT-SC6C-PS0G046M .............................. 1-113
PAT-SC6C-PSIG003M .................................1-112
PAT-SC6C-PSIG008M .................................1-112
PAT-SC6C-PSIG016M ..................................1-112
PAT-SC6C-PSIG023M .................................1-112
PAT-SC6C-PSIG031M...................................1-112
PAT-SC6C-PSIG038M .................................1-112
PAT-SC6C-PSIG046M .................................1-112
PAT-SC8z-R10CxxxM ................................. 2-10
PAT-SC8z-R20CxxxM ................................ 2-10
PAT-SC8z-R30CxxxM ................................ 2-10
PAT-SC8z-R40CxxxM ................................ 2-10
PAT-SC9z-R10BxxxM ...................................2-11
PAT-SC9z-R20BxxxM ..................................2-11
PAT-SC9z-R30BxxxM ..................................2-11

PAT-SCMC-P10B .............................................1-16
PAT-SCMC-P20B ............................................1-16
PAT-SCMC-P30B ............................................1-16
PAT-SCMC-PS0B ............................................1-16
PAT-SCSC-P10C ..............................................1-16
PAT-SCSC-P20C .............................................1-16
PAT-SCSC-P30C .............................................1-16
PAT-SCSC-P40C .............................................1-16
PAT-SCSC-PS0C .............................................1-16
PAT-SCSC-R20C001M ..............................1-142
PAT-SCSC-R20C002M .............................1-142
PAT-SCSC-R20C003M .............................1-142
PAT-SCSC-R20C005M .............................1-142
PAT-SCSC-R30C001M ..............................1-143
PAT-SCSC-R30C002M .............................1-143
PAT-SCSC-R30C003M .............................1-143
PAT-SCSC-R30C005M .............................1-143
PAT-SCTC-P10C ...............................................1-16
PAT-SCTC-P20C .............................................1-16
PAT-SCTC-P30C .............................................1-16
PAT-SCTC-PS0C .............................................1-16
PAT-TC8z-R10BxxxM .................................. 2-10
PAT-TC8z-R20BxxxM ................................. 2-10
PAT-TC8z-R30BxxxM ........................2-10, 2-11
PAT-TC8z-R40BxxxM ................................. 2-10
PAT-TC9z-R10BxxxM ....................................2-11
PAT-TC9z-R20BxxxM ...................................2-11
PAT-TCTC-P10C ...............................................1-16
PAT-TCTC-P30C ..............................................1-16
PAT-TCTC-PS0C ..............................................1-16
PP24AC5ET .......................................3-39, 3-125
PP24AC6AT..........................................3-8, 3-127
PP24AC6T ..........................................3-22, 3-126
PP48AC5ET.......................................3-39, 3-125
PP48AC6AT .........................................3-8, 3-127
PP48AC6T .........................................3-22, 3-126
PWBP-2023 .............................3-6, 3-20, 3-36
PWBP-4023 .............................3-6, 3-20, 3-36
PWBP-6023 ......................................... 3-6, 3-20

Q

QCH-1RU ............................................................. 5-7
QCH-2RU ............................................................ 5-7
QCH-4RU ............................................................ 5-7
QCPP-24MC6AS ............................................5-15
QCPP-24MC6AU ...........................................5-15
QCPP-24MC6U ...............................................5-15
QCPP-48MC6AS ...........................................5-15
QCPP-48MC6AU ...........................................5-15
QCPP-48MC6U ..............................................5-15
QCPU-MCBM-1 ............................................... 5-10
QCPU-MPPM-1 ................................................5-15
QDR-1RU .................................................. 1-53, 5-7

Sc9_Index_v1.indd   34

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-35

www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  1/13  313948AE

INDEX

QDR-2RU ................................................. 1-53, 5-7
QDR-4RU................................................. 1-53, 5-7
QFA-1FFM3PN ..................................................5-11
QFA-1FFM4PN .................................................5-11
QFA-1KKSMPN .................................................5-11
QFA-1MPM3PN .................................................5-11
QFA-1MPM4PN ................................................5-11
QFA-1PPM3PN..................................................5-11
QFA-1PPM4PN .................................................5-11
QFA-1RKSMPN .................................................5-11
QFA-1WWSMPN ..............................................5-11
QFA-2FFM3PN ................................................5-11
QFA-2FFM4PN ................................................5-11
QFA-2KKSMPN ................................................5-11
QFA-2PPM3PN ................................................5-11
QFA-2PPM4PN ................................................5-11
QFA-2WWSMPN ............................................5-11
QFA-4FFM3PN ................................................5-11
QFA-4FFM4PN ................................................5-11
QFA-4KKSMPN ...............................................5-11
QFA-4PPM3PN ................................................5-11
QFA-4PPM4PN ................................................5-11
QFA-4WWSMPN ............................................5-11
QFA-8FFM3PN ................................................5-11
QFA-8FFM4PN ................................................5-11
QFA-8KKSMPN................................................5-11
QFA-8PPM3PN ................................................5-11
QFA-8PPM4PN ................................................5-11
QFA-8WWSMPN ............................................5-11
QFB-48FDLCLMMHR ..................................5-9
QFB-48FDLCLSMHR ...................................5-9
QFB-48FDLCMMMHR .................................5-9
QFB-48FDLCMSMHR ..................................5-9
QFB-192FMPOMMHR ...................................5-9
QFB-192FMPOSMHR ....................................5-9
QFPC-MKKSMPA ......................................... 5-10
QFPC-MKKSMPB ......................................... 5-10
QFPC-MPPM3PA .......................................... 5-10
QFPC-MPPM3PB .......................................... 5-10
QFPC-MPPM4PA .......................................... 5-10
QFPC-MPPM4PB .......................................... 5-10
Q-IPCCM-KT ................................................... 5-14
Q-IPEG-KT ....................................................... 5-14
Q-OFX-GL ........................................................ 5-14
Q-OFX-GR ........................................................ 5-14
Q-OFX-V ........................................................... 5-14
QUCH-1RU .........................................................1-53
QUCH-2RU........................................................1-53
QUCH-4RU .......................................................1-53
QUFB-32FDLCMM4HR ............................1-104
QUFB-32FDLCMSMHR ............................1-104
QUFB-48FDLCLMMHR ............................. 1-54
QUFB-48FDLCLSMHR .............................. 1-54

QUFB-48FDLCMM3HR ............................. 1-54
QUFB-48FDLCMSMHR ............................. 1-54
QUFB-192FMPOMMHR ............................. 1-54
QUFB-192FMPOSMHR............................... 1-54

R

RINST-TOP7 ..................................................... 1-89 
RMG-00ADP00 .............................................1-55
RMG-06ADPC1 .................................... 1-56, 1-91
RMG-06ADPC2 ................................... 1-56, 1-91
RMG-06ADPC5 ...............................................1-91
RMG-06ADPT1 ..................................... 1-56, 1-91
RMG-06ADPT2 ................................... 1-56, 1-91
RMG-12ADPC3 .........................1-56, 1-91, 1-142
RMG-12ADPC4 ............1-56, 1-91, 1-143, 1-144
RMG-12ADPC6 .................................................1-91
RMG-12ADPC7 ............................................... 1-56
RMG-12ADPC8 ...................................1-56, 1-145
RMG-12ADPQ1 ...................................... 1-56, 1-91
RMG-12ADPQ2 ..................................... 1-56, 1-91
RMG-12ADPQ5..................................... 1-56, 1-91
RMG-12MPODQ4 .......................................... 1-59
RMG-12MPOFQ4 ........................................... 1-59
RMG-12MPOSC8 ........................................... 1-59
RMG-12MPOSQ8 ........................................... 1-59
RMG-24ADPQ3 .......................1-56, 1-91, 1-142
RMG-24ADPQ4 ..........1-56, 1-91, 1-143, 1-144
RMG-24ADPQ8 .......................1-56, 1-91, 1-145
RMG-24MPODQ4 ......................................... 1-59
RMG-24MPOFQ4 ......................................... 1-59
RMG-1000-000B ...................................................  
 

1-55, 1-59, 1-142, 1-143, 1-144, 1-145

RMG-2000-000B .................................................  
 

1-55, 1-59, 1-142, 1-143, 1-144, 1-145

RMG-4000-000B .................................................
 

 ........1-55, 1-59, 1-142, 1-143, 1-144, 1-145

RMG-ACC001 ...................................................1-55
RMG-ACCQBRKT4RU .................... 1-55, 1-59

T

TCPC-5ENUVA-XXYYF ............................3-44
TCPC-5ERUVA-XXYYF .............................3-44
TCPC-5ERUVB-BL .....................................3-125
TCPC-5ERUVB-WT ...................................3-125
TCPC-5ERUVB-XXYYF ............................3-44
TCPC-5ERUVX-XXYYF .............................3-44
TCPC-5ESUVA-BLxxF ............................... 1-116
TCPC-5ESUVAGNxxF ................................ 1-116
TCPC-5ESUVA-GYxxF ............................... 1-116
TCPC-5ESUVA-RDxxF ............................... 1-116
TCPC-5ESUVA-WTxxF .............................. 1-116
TCPC-5ESUVA-YLxxF ................................ 1-116
TCPC-5ESUVB-BLxxF ............................... 1-116

TCPC-5ESUVB-GNxxF .............................. 1-116
TCPC-5ESUVB-GYxxF ............................... 1-116
TCPC-5ESUVB-RDxxF .............................. 1-116
TCPC-5ESUVB-WTxxF .............................. 1-116
TCPC-5ESUVB-YLxxF................................ 1-116
TCPC-6ARFVA-BLxxF ............................... 1-118
TCPC-6ARFVA-GNxxF .............................. 1-118
TCPC-6ARFVA-GYxxF............................... 1-118
TCPC-6ARFVA-RDxxF .............................. 1-118
TCPC-6ARFVA-WTxxF .............................. 1-118
TCPC-6ARFVA-XXYYF ...............................3-11
TCPC-6ARFVA-YLxxF ............................... 1-118
TCPC-6ARFVB-BLxxF .............................. 1-118
TCPC-6ARFVB-GNxxF ............................. 1-118
TCPC-6ARFVB-GYxxF .............................. 1-118
TCPC-6ARFVB-RDxxF .............................. 1-118
TCPC-6ARFVB-WTxxF ............................. 1-118
TCPC-6ARFVB-XXYYF ...............................3-11
TCPC-6ARFVB-YLxxF ............................... 1-118
TCPC-6ARUVA-XXYY .................................3-12
TCPC-6ARUVB-XXYY ................................3-12
TCPC-6RUVA-BLxxF .................................. 1-118
TCPC-6RUVA-GNxxF ................................. 1-118
TCPC-6RUVA-GYxxF .................................. 1-118
TCPC-6RUVA-RDxxF ................................. 1-118
TCPC-6RUVA-WTxxF ................................. 1-118
TCPC-6RUVA-XXYYF ............................... 3-25
TCPC-6RUVA-YLxxF .................................. 1-118
TCPC-6RUVB-BKxxF ................................. 1-118
TCPC-6RUVB-BLxxF .................................. 1-118
TCPC-6RUVB-GNxxF................................. 1-118
TCPC-6RUVB-GYxxF ................................. 1-118
TCPC-6RUVB-RDxxF ................................. 1-118
TCPC-6RUVB-WT ......................................3-126
TCPC-6RUVB-WTxxF ................................ 1-118
TCPC-6RUVB-XXYYF ............................... 3-25
TCPC-6RUVB-YLxxF .................................. 1-118
TCPC-6RUVX-XXYYF ............................... 3-25
TCPV-6RUVB-BL ........................................3-126
TE510P25-XX02 ........................................... 3-35
TE510P-XX02 ................................................ 3-35
TE510P-XXII .................................................... 3-35
TE510R25-XX02 ........................................... 3-35
TE510R-XX02 ................................................ 3-35
TE510R-XXII .................................................... 3-35
TE520P ............................................................3-125
TE520PF-XX02 ............................................ 3-33
TE520PX2-XX02 .......................................... 3-32
TE520P-XX02 ............................................... 3-32
TE520P-XXII ................................................... 3-32
TE520P-XXRB ............................................... 3-32
TE520R ............................................................3-125
TE520RF-XX02 ............................................ 3-33

Sc9_Index_v1.indd   35

12/18/12   1:04 PM

Tyco-catalog-AMP-2013-html.html
background image

Index

By Part Number

9-36

www.te.com/EnterpriseNetworks +1-800-553-0938Fax: 1-717-986-74061/13313948AE

INDEX

TE520RX2-XX02 ......................................... 3-32
TE520R-XX02 ............................................... 3-32
TE520R-XXII .................................................. 3-32
TE520R-XXRB .............................................. 3-32
TE610P-XX02 ..................................................3-19
TE610P-XX06 ..................................................3-19
TE610P-XXII ......................................................3-19
TE610R-XX02 ..................................................3-19
TE610R-XX06 ..................................................3-19
TE610R-XXII......................................................3-19
TE620P ............................................................3-126
TE620PX2-XX02 ...........................................3-17
TE620P-XX02 .................................................3-17
TE620P-XXll .....................................................3-17
TE620P-XXRB ................................................3-17
TE620R ............................................................3-126
TE620RX2-XX02 ...........................................3-17
TE620R-XX02 .................................................3-17
TE620R-XXll.....................................................3-17
TE620R-XXRB ................................................3-17
TE630P-XX02 .................................................3-16
TE630P-XXRB ................................................3-16
TE630R-XX02 .................................................3-16
TE630R-XXRB ................................................3-16
TE640OSP-BK02 ...........................................3-5
TE640P ............................................................ 3-127
TE640PF .........................................................3-128
TE640PF-XX02 ...............................................3-3
TE640P-XX02 ..................................................3-4
TE640R ........................................................... 3-127
TE640RF ........................................................3-128
TE640RF-XX02 ...............................................3-3
TE640R-XX02 ..................................................3-4
TE5200SP-BK02 .........................................3-34
TE5200SP-BKRB ........................................3-34
TE6200SP-BK02 ...........................................3-18
TE6200SP-BK06 ...........................................3-18
TFP 1-62
TFP-00AP00 ......................................1-63, 1-107
TFP-1TT00-000B ....................1-63, 1-68, 1-71,  
 

1-107, 1-142, 1-143, 1-144, 1-145

TFP-2TT00-000B...................1-63, 1-68, 1-71,  
 

1-107, 1-142, 1-143, 1-144, 1-145

TFP-4TT00-000B ................1-63, 1-68, 1-107
TFP-5TT00-000B ...............1-63, 1-68, 1-107,  
 

1-142, 1-143, 1-144, 1-145

TFP-12APLA1 ..................................................1-107
TFP-12APLC3 ......................................1-64, 1-142
TFP-12APLC4.........................1-64, 1-143, 1-144
TFP-12APLC4DE3 ........................................1-64
TFP-12APLC8 ......................................1-64, 1-145
TFP-12APLC8SB3 .........................................1-64
TFP-12APRA1 .................................................1-107

TFP-12APRC3 .....................................1-64, 1-142
TFP-12APRC4 ........................1-64, 1-143, 1-144
TFP-12APRC4DE3 ........................................1-64
TFP-12APRC8 .....................................1-64, 1-145
TFP-12APRC8SB3 ........................................1-64
TFP-12MPLDQ2 ............................................. 1-68
TFP-12MPLFQ2 .............................................. 1-68
TFP-12MPLSQ5 ..................................1-68, 1-107
TFP-12MPRDQ2 ............................................. 1-68
TFP-12MPRFQ2.............................................. 1-68
TFP-12MPRSQ5 .................................1-68, 1-107
TFP-24APLQ1 .....................................1-64, 1-142
TFP-24APLQ2 .......................1-64, 1-143, 1-144
TFP-24APLQ2DE3 .......................................1-64
TFP-24APLQ5 ....................................1-64, 1-145
TFP-24APLQ5SB3 .......................................1-64
TFP-24APRQ1 ....................................1-64, 1-142
TFP-24APRQ2 ......................1-64, 1-143, 1-144
TFP-24APRQ2DE3 ......................................1-64
TFP-24APRQ5 ...................................1-64, 1-145
TFP-24APRQ5SB3 ......................................1-64
TFP-24MPLDQ2 ............................................ 1-68
TFP-24MPLFQ2 ............................................ 1-68
TFP-24MPLSQ5 ............................................ 1-68
TFP-24MPRDQ2 ........................................... 1-68
TFP-24MPRFQ2 ............................................ 1-68
TFP-24MPRSQ5 ............................................ 1-68
TFP-72AP0MP .................................................1-71
TFP-ACC002 ....................................................1-71
TFP-VELSTP ................................................... 1-63
TMRJ-1SUPB-SA0xxM ...............................3-57
TMRJ-1SUPB-SH0xxM ...............................3-57
TMRJ-1SUPB-SS0xxM ................................3-57
TMRJ-1SURG-AH0xxM ..............................3-57
TMRJ-1SURG-SA0xxM ...............................3-57
TMRJ-1SURG-SH0xxM ...............................3-57
TMRJ-1SURG-SS0xxM ...............................3-57
TMRJ-1UURG-SS0xxM ...............................3-57
TMRJ-1UURG-SS002M ............................. 3-55
TMRJ-1UURG-SS003M ............................. 3-55
TMRJ-1UURG-SS004M ............................. 3-55
TMRJ-1UURG-SS005M ............................. 3-55
TMRJ-1UURG-SS006M ............................. 3-55
TMRJ-1UURG-SS007M ............................. 3-55
TMRJ-1UURG-SS008M ............................. 3-55
TMRJ-1UURG-SS009M ............................. 3-55
TMRJ-1UURG-SS010M .............................. 3-55
TMRJ-1UURG-SS012M ............................... 3-55
TMRJ-1UURG-SS015M ............................... 3-55
TMRJ-1UURG-SS017M ............................... 3-55
TMRJ-1UURG-SS020M ............................. 3-55
TMRJ-1UURG-SS025M ............................. 3-55
TMRJ-1UURG-SS030M ............................. 3-55

TMRJ-XSSRW-SAXXXM .......................... 3-53
TMRJ-XSSRW-SSXXXM ........................... 3-53
TP5ETB0BLXX ............................................. 3-92
TP5ETB0GNXX ............................................ 3-92
TP5ETB0GYXX ............................................. 3-92
TP5ETB0RDXX ............................................. 3-92
TP5ETB0WTXX ........................................... 3-92
TP5ETB0YLXX ............................................. 3-92
TP5ETB-BLXX............................................... 3-93
TP5ETB-GNXX ............................................. 3-93
TP5ETB-RDXX .............................................. 3-93
TP5ETB-WTXX ............................................. 3-93
TP5ETB-YLXX ............................................... 3-93
TP5ETF-BLXX ............................................... 3-92
TP5ETF-GNXX .............................................. 3-92
TP5ETF-GYXX .............................................. 3-92
TP5ETF-RDXX .............................................. 3-92
TP5ETF-WTXX ............................................. 3-92
TP5ETF-YLXX ............................................... 3-92
TP6ATB0XXYY...............................................3-15
TP6ATB-XXYY ................................................3-15
TP6ATH0XXYY ..............................................3-15
TP6ATH-XXYY ................................................3-15
TP6TB0BLXX ................................................ 3-28
TP6TB0GNXX ............................................... 3-28
TP6TB0GYXX................................................ 3-28
TP6TB0RDXX................................................ 3-28
TP6TB0WTXX .............................................. 3-28
TP6TB0YLXX ................................................ 3-28
TP6TB-BLXX ................................................. 3-28
TP6TB-GNXX ................................................ 3-28
TP6TB-GYXX ................................................. 3-28
TP6TB-RDXX ................................................. 3-28
TP6TB-WTXX ................................................ 3-28
TP6TB-YLXX .................................................. 3-28
TP6TH-BLXX ................................................. 3-28
TP6TH-GNXX ................................................ 3-28
TP6TH-GYXX ................................................. 3-28
TP6TH-RDXX ................................................. 3-28
TP6TH-WTXX ............................................... 3-28
TP6TH-YLXX .................................................. 3-28

Sc9_Index_v1.indd   36

12/12/12   2:43 PM

Tyco-catalog-AMP-2013-html.html
background image

CATALOG

Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved.

313948AE1/13Original  © 2013

ADC, AirES, AMP, AMP NETCONNECT, AMPINNERGY, AMPMODU, AMP-TWIST, Compact Building, 

CopperTen,  Express  Exit,  FiberGuide,  FL2000,  HighBand,  KRONE,  LightCrimp  PLUS,  

LSA-PLUS, MPO Optimate, MRJ21,  MT-RJ SECURE, NETCONNECT, NETpodium, OMX, OPTIMATE, 

Pro-Crimper, Quareo, Quick-Fit, RapidReel, RealFlex, RJ45, Sigma-Link, SlimLine, Snap-Fit, TracerLight, TrueNet, Tyco, Ultim8, TE Connectivity, 

TE connectivity (logo), Tyco Electronics, and TE (logo) are trademarks. 

 

While TE Connectivity has made every reasonable effort to ensure the accuracy of the information in this document, TE Connectivity does 

not guarantee that it is error-free, nor does TE Connectivity make any other representation, warranty or guarantee that the information is 

accurate, correct, reliable or current. TE Connectivity reserves the right to make any adjustments to the information contained herein at 

any time without notice. TE Connectivity expressly disclaims all implied warranties regarding the information contained herein, including, 

but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are 

for  reference  purposes  only  and  are  subject  to  change  without  notice.  Specifications  are  subject  to  change  without  notice.  Consult 

TE Connectivity for the latest dimensions and design specifications.

1st Edition

TE Connectivity Enterprise Networks

Product Catalog

Featuring AMP NETCONNECT

and TrueNet product brands

Contact us:

Greensboro, NC 
USA 27409-8420
Tel: 1-800-553-0938 
Fax: 1-717-986-7406

www.te.com/EnterpriseNetworks

Ent

erprise Netw

orks Pr

oduct Ca

talog

          1s

t E
dition          

w

w

w

.te

.c

om/Ent

erpriseNetw

orks

Sc0_Cover_TOC_v1_COMBINED.indd   4

12/18/12   12:49 PM