background image

S m a r t   +   T e c h n o l o g y   +   H u m a n

Always with

www.samwhaflex.co.kr

SAMWHA ELECTRIC

SAMWHA

ELECTRIC

SAMWHA PRODUCTS GUIDE

SAMWHA

PRODUC

T
GUIDE

catalog_eng-html.html
background image

Leading
Innovation Growth

Samwha  Electric Co., Ltd., which has been in business since  1980 as a truly all-around maker of electrical
tubing materials and fittings based on its advanced technology and reputation, 
has been highly recognized for performance and value in the markets such as petrochemistry plants, local
and overseas nuclear power plants, engineering works, construction sites, shipyards and machine tools.

A company who connects people, technology and the future -
Samwha Electric stands at the center of the world 

catalog_eng-html.html
background image

CONTENTS

P R O D U C T   G U I D E

Smart  +  Technology  +  Human

2 _ 3

This catalogue is subject to change without prior notice and can be used
as both sectional and comprehensive.

Lighting Fixtures

Enclosures/Controls/Panels

Industrial Fittings

Cable Glands

Electrical Conduit Systems/
Cable Trays

Controls/Terminal Blocks

Power/Control Panels

Appendix

Index

A

B

C

D

E

F

G

catalog_eng-html.html
background image

COMPANY  INFORMATION

We Create 
Leading Solution

Samwha’s advanced technology proves its real merits out of sight and even in
unexpected small places aiming for respect for man’s life and dignity, protection of
environment, creation of happy future value by using safely and comfortably  electricity,
the invisible power that makes the World move.

Samwha’s varied solutions made with constant reliability and advanced technology
confidently secure absolute safety and convenient construction. 

Samwha promises solemnly to be with its customers at all times at the center of every
place where electricity is being used, and its effort and sincerity will be continued now
and in the future forever until the demand for each of its customers has been
completely fulfilled.

A light brightening up the hope of tomorrow,
Challenge behind the scenes has already started.
Soundless yet powerful heartbeats continue.

catalog_eng-html.html
background image

Smart  +  Technology  +  Human

4 _ 5

We will become the 21

st

century leader in the electrical

construction material manufacturing area, who focuses on
green business and touches the hearts of customers beyond
giving satisfaction

Samwha’s Vision for the

Present and the Future

catalog_eng-html.html
background image

COMPANY  HISTORY

A Company 
with Samwha Values

Samwha’s Origin and Development
What Samwha makes is something different and reliable, and becomes a benchmark.

Samwha’s obstinately long and distinguished experience in pursuit of progress of electrical construction 
material field is the living history of the industry.
Its steady and substantial growth  could be done by virtue of its customers’ constant support and
encouragement as  each step forwarded with a sense of duty and responsibility that leads 
the industry as a representative.
The credibility that what Samwha makes something different and reliable is 
its precious asset and honor which can’t be traded with anything, 
and pride not to be compromised.

1980

02  Converted to corporate body and 

Samwha established

02  Seoul business office set up
06  Patent on utility model for Cable Tie obtained
09  Patent on utility model for Terminal Block obtained
10  Patent on  registration of design for 

Power Supply Wiring Equipment

1981

11  Factory registration approved.

1982

09  Technical tie-up with Sankei, Japan

1983

09  Joining Korea Electronics Association 

and registering electronic industry at KEA

10  Prize of Minister, Ministry of Commerce 

and Industry awarded for Master Controller 
at the 14th selection for superb 
development by KEA

1984

07  Busan business office set up
12  Technical tie-up with Osaka Rasen, 

Japan

12  Appointed as a promising small and 

medium enterprise by  SC First Bank

1986

03  Patent on utility model for Common 

Terminal Unit obtained

07  Patent on  registration of design for 

Settling Equipment for Electrical
Pipe obtained

1989

03  Factory #2 registration approved
04  UL listed for Terminal Block
07  Q Mark for the entire products obtained
12  Construction work of Cheonan 

Factory completed

1980~1989

Lay the groundwork for 
a high-technology company

catalog_eng-html.html
background image

Smart  +  Technology  +  Human

6 _ 7

Present a blueprint 
for the next big push

Grow into global business

1990

02   KS Mark for Flexible Metal Conduit obtained
10   Extension work of Cheonan Fatory completed

1994

08   KS Mark for Fittings of Flexible Metal Conduit obtained

1998

01   Certificate of ISO 9001 obtained
03   Certificate of EM Mark obtained
09   Certificate of EQ Mark obtained

1990~1999

2000

07  Baseefa Certificate obtained

2001

05  UL Certificate obtained for the entire sizes of the 

1st Class Flexible Metal Conduit

2003

04  Europe integrated CE Certification Mark obtained

2004

04  ABS(American Bureau of Shipping) Certificate obtained

2005

05  Appointed as a panel company on industrial and technical 

policy of Ministry of Commerce, Industry and Energy

2006

01  ERP system adopted and built up
09  Certificate of ISO 14001 obtained

2008

11  Ulsan business office set up
12  Certficate of KEPIC obtained

2009

08  CRM system adopted

2010

04  Technical Institute registered and established

2011

02  Seoul business office moved

2000~

catalog_eng-html.html
background image

RESEARCH & DEVELOPMENT

Creating Solution  
Through Innovation

catalog_eng-html.html
background image

Global 

Solution

Creative

Imagination

Human 

Infra Build

Smart  +  Technology  +  Human

8 _ 9

A Group of Blue-Chip 

Research Staff

Environment-Friendly 

Product Development

User-Oriented R & D

User-Oriented R&D

Through the advanced technologies leading the industry and CRM

(Consumer Relation Management), Samwha listens to VOC(Voice of

Customer) in connection with sales–marketing-R&D–production – A/S,

conducts an user-oriented R&D based on market needs, and produces

reliable products convenient to handle at job sites.

A Group of Blue-Chip Research Staff

The well trained R&D staff with a long experience and accumulated

know-how take the lead in brand-name product development through

the capabilities of analyzing variously, combining, and applying expert

knowledge.

Environment-Friendly Product Development

Beginning with obtaining a certificate of ISO 14000 in 2006, all of the

Samwha products have been designed at an early stage of R&D and

manufactured caring about protection of the environment, conservation

and recycling of resources.

Leading Company 
of Electrical Construction Materials in 21C

Samwha has made ungrudging investments and efforts into R&D,
a fortune growth engine.
As an integrated institute was renovated from a system which had
been operated with the R&D work force as 
a central figure, it could possess more vital research capabilities
in the aspects of acquisition, creation, sharing and application of
knowledge to accomplish innovations in technique.

catalog_eng-html.html
background image

QUALITY & SERVICE

With High Facility & Quality

catalog_eng-html.html
background image

Best Quality

Smart  +  Technology  +  Human

10 _ 11

Customer Service

Establishment of a regular A/S system to meet customers demand

Activities for immediate measures against claims and preventing reoccurance

Technical assistance for proper production selection and use by customers

Production Quality Control  

Thorough implementation and observance of the established QC system

Rigid QC control as per each work process

The finest production surpassing KS standards

Credibility

Product design considering various regulations and practical functions

Verification of product reliability through credible tests

Continuous quality improvement activities through feedback

We are developing customer confidence and
satisfaction by operating an environment-friendly
workplace equipped with the finest facilities and the
state-of-the-art systems and a systematic quality
control of products

Samwha secures safety and credibility in any working circumstances
with the internally best production facility.
It is its mission and reward to its customers who return with trust to
supply high quality products surpassing KS standard at as reasonably
competitive or lower prices as possible than its competitors since its
establishment.
In order to care about any little unavoidable inconvenience and
discontent occurring even at that, A/S system has been operated to
take an immediate action anytime and anywhere.

catalog_eng-html.html
background image

BUSINESS SHOWINGS

We Create 
the Next Samwha

catalog_eng-html.html
background image

Smart  +  Technology  +  Human

12 _ 13

The customers who have experienced Samwha’s excellent solutions and services
return to Samwha retaining the fact in memory.
It is because Samwha, which has concentrated only on electrical construction
material field since its foundation, can provide appropriate solutions for customers’
needs by supplying the products made with high technical skills proved by various
kinds of the nationwide and international certificates.
The reputation for Samwha proves gradually its real worth not only local projects 
but also overseas ones.
Samwha has confidence that the solutions recognized first by its customers are its most
powerful competitive edge and source of customer surprise.

Customers recognized our customer satisfaction-oriented 
business through the realization of customer value, advanced
technologies, reliable solutions, and the excellent quality and 
performance of products. 

Global 

Samwha

catalog_eng-html.html
background image

Safe Lighting, Pleasant Lighting

Samwha's lighting fixtures, which have obtained the Explosion Proof Certification, 

are both heatproof and corrosion resistant products. They are always capable of creating a safe,

pleasant lighting environment even in the most hazardous areas.

catalog_eng-html.html
background image

Smart  +  Technology  +  Human

A

A

Lighting Fixtures

Contents

Lighting Fixtures

LEU Series - Ex d II C IP66  Lighting Fixture

LNS Series - Ex nR II IP66  Lighting Fixture

LES Series - Ex d II B IP54  Lighting Fixture

SEU Series - Ex d II C IP66  Lighting Fixture

SES Series - Ex d II B IP54  Lighting Fixture

FLES Series - Ex d II B IP65  Fluorescent Lighting

FLNS Series - Ex nR II IP65  Fluorescent Lighting

FLXS Series - For Non. Hazar. IP66

Fluorescent Lighting

LXS Series - For Non. Hazar. Dust & Vapor Proof IP65

Lighting Fixture

SXS Series - For Non. Hazar. Dust & Vapor Proof IP65 

Lighting Fixture

LEH Series - Ex d II C IP66  Hand Lamp Lighting

LET Series - Ex d II B IP66  Tank Lighting

LEF Series - Ex d II B T3 IP66  Flood Lighting

LNF Series - Ex nR II T3 IP66  Flood Lighting

A4

A11

A18

A21

A25

A28

A30

A32

A34

A37

A39

A41

A43

A45

catalog_eng-html.html
background image

Lighting Fixtures

A

catalog_eng-html.html
background image

Lighting Fixtures

A2 _ A3

Lighting Fixtures

A

catalog_eng-html.html
background image

LEU Series - Ex d II C IP66  

Lighting Fixture

Ex d II C IP66

IEC 60079-0, 1

IEC 60529 

Applications

LEU Series Lighting Fixtures are designed for installations where moisture, dirt, dust, corrosion 

and vibration may be present, or IEC 60529 IP66 areas where wind, water, snow or high ambient 
can be expected.  

They can be used in locations made hazardous due to the presence of flammable or explosive 

gases, vapors and combustible dusts as defined by the IEC 60079-0,1.

Applications include classified areas such as paint manufacturing plants, ammunition facilities, 

oil and gas producing and refining plants, off-shore and dockside installations, tank farms, 
pipeline pumping stations and marine loading and fuel transfer terminals. 

Hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired.

Features

Fixture is factory wired; power is fed through “wireless”connection block which serves as a mechanical

seal between conduit and ballast compartments, eliminating the need for a field installed seal. The result

is fast, easy installation.

Wide range of light sources and wattages to meet specific lighting needs – 30 and 85 Fluorescent; 100, 150,

250 and 400W high pressure sodium (HPS); 250 and 400W mercury vapor (MV); 175, 250 and 400W metal
halide (MH).

Four light sources – Compact fluorescent, high pressure sodium, metal halide and mercury vapor.

Mounting choice – Pendant, Ceiling,25

°

Stanchion, 40

°

or 90

°

wall mount, all with “wireless ” design that

allows fast, easy fixture installation.

Integral ballasts – separate ballasts are not required. Lowest installed cost.

Corrosion resistant – Copper-free aluminum die cast construction. Baked powder epoxy finish, electro

statically Exposed hardware is stainless steel.

Pendant type is standard.

Standard Materials

Copper-free Aluminium (Cast Aluminium Alloy)

Globe : Heat Resistant Glass

Reflector : High Purity Aluminium 

Guard & Accessory : Stainless Steel

Options

Fuse – to protect ballast and capacitors against

abnormal line conditions.

One fuse required for 120 or 277VAC units

Two fuses needed for 208,240 or 480VAC units

Instant re-strike ballast – enables a hot HPS

lamp to immediately re-strike after a momentary
loss of arc due to voltage fluctuation or power
outage. It has no effect on the warm-up period of
cold lamps (Max 150W HPS only).

Dome reflector or 30

°

angle reflector.

Protect Guard.

High power factor – Minimum P. F. 90%.

Technical Data

Voltage Range - AC 100V~480V

Watts Range - 30~400W

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Certification

Certified by KOSHA 

(Korea Occupational Safety & Health Agency) 

Weight

18 kg 

Compliances

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof 
enclosures “d” 

ANSI /ASME B 1.20.1 Pipe threads, General 

purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight 
joints are not made on the threads

ISO 261 Metric screw thread

Lighting Fixtures

A

catalog_eng-html.html
background image

Model Number Logic

ex) Metal Halide High power factor type Stanchion Mounting, AC220V, 250W, Guard required 

MLEU 25 22 ST G P

Series 
Constant 

LEU

Lamp Wattage

03- 30W-C
08- 85W-C
10-100W-S
15-150W-S
17-175W-M
25-250W-M.S.V
40-400W-M.S.V

00

Voltage

@

60Hz

12-AC120V
20-AC208V
22-AC220V
24-AC-240V
27-AC277V
48-AC480V 

00

Mounting Type

PT-Pendant 
CL-Ceiling
ST-Stanchion
4B-40

°

Bracket

9B-90

°

Bracket

00

0

G-Omit G if guard

is not required

0

P-Omit P if High
powerfactor 
is not required

Lamp Type

C-Fluorescent
S-HPS (High
pressure sodium)
M-Metal
V-Mercury

0

Lighting Fixtures

A4 _ A5

Lighting Fixtures

A

Dimensions

40° Wall Mount Type

90° Wall Mount Type

Standard Type Reflector

30° Dome Type Reflector

Ceiling Type

Stanchion Type

Pendant Type

Dimensions (mm) 

catalog_eng-html.html
background image

0

1

2

3

4

5

6

7

8

9

10

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

19 

21 

25 

34 

42 

47 

53 

55 

55 

55 

66 

77 

88 

96 

98 

100

102

106

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

107 

107 

103 

97 

77 

43 

11

1

0

-

-

-

80

Angle

Angle

cd/1000 lm

cd/1000 lm

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.84 .84 .84 .84 .79 .79 .79 .79 .70 .70 .70 .61 .61 .61 .53 .53 .53 .50

.71 .66 .61 .56 .66 .61 .57 .52 .53 .49 .46 .46 .43 .40 .39 .36 .34 .31

.64 .54 .47 .41 .58 .50 .44 .38 .43 .38 .34 .37 .33 .29 .31 .27 .25 .21

.56 .46 .38 .32 .51 .42 .35 .30 .36 .30 .26 .30 .26 .22 .25 .22 .18 .15

.50 .40 .32 .26 .46 .37 .30 .24 .31 .25 .21 .26 .22 .18 .22 .18 .15 .12

.46 .34 .27 .21 .42 .32 .25 .19 .27 .21 .17 .23 .18 .14 .19 .15 .12 .09

.42 .30 .23 .17 .38 .28 .21 .16 .24 .18 .14 .20 .15 .12 .17 .12 .09 .07

.38 .27 .19 .14 .35 .25 .18 .13 .21 .15 .11 .18 .13 .09 .15 .11 .08 .06

.35 .24 .17 .12 .32 .22 .16 .11 .19 .14 .10 .16 .11 .08 .13 .09 .06 .05

.33 .22 .15 .10 .30 .20 .14 .10 .17 .12 .08 .15 .10 .07 .12 .08 .05 .04

.30 .20 .13 .09 .28 .18 .12 .08 .16 .11 .07 .13 .09 .06 .11 .07 .05 .03

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

LEU Series - Ex d II C IP66  

Lighting Fixture

Ex d II C IP66

IEC 60079-0, 1

IEC 60529 

Photometric Data

High Pressure Sodium 100W (Reflector: Non)

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

126

128

133

142

143

143

139

133

126

121

126

129

131

100 

49 

26 

14

5

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175


5

10














-

80

Angle

Angle

cd/1000 lm

cd/1000 lm

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.66 .66 .66 .66 .64 .64 .64 .64 .61 .61 .61 .58 .58 .58 .56 .56 .56  .54

.61 .58 .56 .54 .59 .57 .55 .53 .54 .52 .51 .52 .50 .49 .49 .48 .47  .46

.55 .51 .47 .44 .54 .50 .46 .43 .47 .45 .42 .46 .43 .41 .44 .42 .40  .39

.50 .44 .40 .36 .49 .43 .39 .36 .42 .38 .35 .40 .37 .34 .38 .36 .34  .32

.46 .39 .34 .31 .45 .38 .34 .30 .37 .33 .30 .35 .32 .29 .34 .31 .29  .27 

.42 .34 .29 .26 .40 .34 .29 .25 .32 .28 .25 .31 .27 .24 .30 .27 .24  .23

.38 .30 .25 .22 .37 .30 .25 .21 .29 .24 .21 .27 .24 .21 .26 .23 .20  .19

.35 .27 .22 .18 .34 .26 .21 .18 .25 .21 .18 .24 .20 .17 .23 .20 .17  .16

.32 .24 .19 .16 .31 .24 .19 .16 .23 .18 .15 .22 .18 .15 .21 .18 .15  .14

.33 .22 .17 .14 .29 .21 .17 .14 .21 .16 .13 .20 .16 .13 .19 .16 .13  .12

.27 .20 .15 .12 .27 .19 .15 .12 .19 .15 .12 .18 .14 .12 .17 .14 .11  .10

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

High Pressure Sodium 100W (Reflector: Dome)

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

180
175
165
155
145
135
125
115
105

95
90
85
75
65
55
45
35
25
15

5
0

-
-
-
-
-
-
-
-
-
-
-

2.00

18.53
54.32

122.74
116.21
131.79
133.47
127.05
114.63
114.63

-
-
-
-
-
-
-
-

5.37

20.63
32.63
60.84

148.95
161.05
159.05
151.47
156.21
146.53
135.26
118.74
114.63

-
-
-
-
-
-
-

3.16

15.37
45.79
84.53

119.47
173.58
181.26
172.42
164.42
157.89
149.58
134.84
120.84
114.63

80

Reflector

cd/1000lm cd/1000lm cd/1000lm

Angle

90

100W 100W

100W

45

0

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.68 .68 .68 .68 .66 .66 .66 .66 .62 .62 .62 .59 .59 .59 .56 .56 .56  .55

.60 .57 .54 .51 .58 .56 .53 .50 .52 .50 .48 .50 .48 .46 .47 .46 .44  .43

.54 .49 .45 .41 .53 .48 .44 .40 .45 .42 .39 .43 .40 .37 .41 .38 .36  .35

.49 .42 .37 .33 .47 .41 .36 .33 .39 .35 .32 .37 .34 .31 .35 .32 .30  .28

.45 .38 .32 .28 .43 .37 .32 .28 .35 .30 .27 .33 .29 .26 .31 .28 .26  .24

.41 .33 .23 .23 .40 .32 .27 .23 .31 .26 .23 .29 .25 .22 .28 .25 .22  .20

.38 .29 .24 .20 .36 .29 .24 .20 .27 .23 .19 .26 .22 .19 .25 .21 .19  .17

.34 .26 .21 .17 .33 .26 .20 .17 .24 .20 .17 .23 .19 .16 .22 .19 .16  .15

.32 .24 .18 .15 .31 .23 .18 .15 .22 .18 .14 .21 .17 .14 .20 .17 .14  .13

.29 .21 .16 .13 .28 .21 .16 .13 .20 .16 .13 .19 .15 .12 .18 .15 .12  .11

.27 .19 .14 .11 .26 .19 .14 .11 .18 .14 .11 .17 .13 .11 .17 .13 .11  .10

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

High Pressure Sodium 100W (Reflector: Non)

ZONAL CAVITY METHOD

Lighting Fixtures

A

catalog_eng-html.html
background image

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

17

17

22

30

35

38

41

45

59

70

79

86

92

96

100

104

106

107

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

107

106 

104 

101 

96 

88 

75 

57 

37 

19

7

-2 

-

-

-

-

Angle

Angle

cd/1000 lm

cd/1000 lm

Photometric Data

High Pressure Sodium 400W (Reflector: Non)

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.97 .97 .97 .97 .90 .90 .90 .90 .78 .78 .78 .66 .66 .66 .56 .56 .56 .51

.83 .76 .71 .66 .76 .71 .66 .61 .60 .56 .52 .50 .47 .44 .41 .38 .36 .32

.73 .63 .55 .49 .67 .58 .51 .45 .49 .43 .38 .40 .36 .32 .32 .29 .26 .22

.65 .54 .45 .38 .59 .49 .41 .35 .41 .35 .30 .33 .29 .24 .26 .23 .19 .15

.59 .46 .37 .31 .54 .43 .35 .28 .36 .29 .24 .29 .24 .20 .23 .19 .15 .12

.53 .40 .31 .25 .48 .37 .29 .23 .31 .24 .19 .25 .20 .16 .20 .15 .12 .09

.48 .35 .27 .21 .44 .32 .25 .19 .27 .21 .16 .22 .17 .13 .17 .13 .10 .07

.44 .31 .23 .17 .40 .29 .21 .16 .24 .17 .13 .19 .14 .10 .15 .11 .08 .05

.41 .28 .20 .14 .37 .26 .18 .13 .21 .15 .11 .18 .12 .09 .14 .10 .06 .04

.38 .25 .18 .12 .34 .23 .16 .11 .19 .13 .09 .16 .11 .07 .12 .08 .05 .03

.35 .23 .15 .11 .32 .21 .14 .10 .18 .12 .08 .14 .10 .06 .11 .07 .04 .03

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

119

119

123

129

132

132

130

129

137

142

146

147

146

143

136

108 

75 

39

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

-

Angle

Angle

cd/1000 lm

cd/1000 lm

High Pressure Sodium 400W (Reflector: Dome)

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.89 .89 .89 .89 .87 .87 .87 .87 .82 .82 .82 .78 .78 .78 .75 .75 .75 .73

.79 .74 .70 .67 .77 .73 .69 .65 .69 .66 .63 .65 .63 .60 .62 .60 .58 .56

.70 .63 .57 .51 .68 .61 .55 .50 .58 .53 .49 .55 .51 .47 .52 .49 .46 .44

.63 .53 .46 .40 .60 .52 .45 .40 .49 .43 .39 .47 .42 .38 .44 .40 .37 .35

.57 .46 .39 .33 .55 .45 .38 .33 .43 .37 .32 .41 .36 .31 .39 .34 .31 .29

.51 .40 .33 .27 .49 .39 .32 .27 .37 .31 .26 .36 .30 .26 .34 .29 .25 .23

.47 .35 .28 .22 .45 .35 .27 .22 .33 .27 .22 .31 .26 .21 .30 .25 .21 .19

.43 .31 .24 .19 .41 .30 .23 .18 .29 .23 .18 .28 .22 .18 .27 .21 .17 .16

.39 .28 .21 .16 .38 .27 .21 .16 .26 .20 .16 .25 .19 .15 .24 .19 .15 .13

.36 .25 .18 .14 .35 .25 .18 .14 .24 .18 .13 .23 .17 .13 .22 .17 .13 .11

.34 .23 .16 .12 .33 .22 .16 .12 .21 .16 .12 .21 .15 .11 .20 .15 .11 .10

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.84 .84 .84 .84 .81 .81 .81 .81 .76 .76 .76 .72 .72 .72 .67 .67 .67 .65

.74 .69 .65 .62 .71 .67 .63 .60 .63 .60 .57 .59 .56 .54 .55 .53 .51 .49

.66 .59 .53 .48 .64 .57 .51 .47 .53 .49 .45 .50 .46 .43 .47 .44 .41 .39

.59 .50 .44 .38 .57 .49 .43 .37 .46 .40 .36 .43 .38 .34 .40 .36 .33 .31

.54 .44 .37 .32 .52 .43 .36 .31 .40 .34 .30 .38 .33 .29 .35 .31 .28 .26

.49 .39 .32 .26 .47 .38 .31 .26 .35 .29 .25 .33 .28 .24 .31 .27 .23 .21

.45 .34 .27 .22 .43 .33 .26 .22 .31 .25 .21 .29 .24 .20 .27 .23 .19 .18

.41 .30 .23 .19 .39 .29 .23 .18 .27 .22 .17 .26 .21 .17 .24 .20 .16 .15

.38 .27 .20 .16 .36 .26 .20 .15 .25 .19 .15 .23 .18 .14 .22 .17 .14 .12

.35 .24 .18 .13 .33 .24 .18 .13 .22 .17 .13 .21 .16 .12 .20 .15 .12 .11

.32 .22 .16 .12 .31 .21 .16 .12 .20 .15 .11 .19 .14 .11 .18 .14 .10 .09

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

180
175
165
155
145
135
125
115
105

95
90
85
75
65
55
45
35
25
15

5
0

-
-
-
-
-
-
-

0.08
0.50
2.36
3.88

11.88
71.56

129.84
142.46
136.74
118.32
121.50
118.50
107.64
108.60

-
-
-
-
-
-
-

1.94

21.48
79.90

110.44
138.56
172.12
180.62
180.98
170.28
149.24
143.10
131.12
112.46
108.60

-
-
-
-
-
-

0.54

10.98
53.26

114.98
143.54
155.78
175.92
183.70
189.14
184.44
160.14
146.92
134.40
114.44
108.60

Reflector

cd/1000lm cd/1000lm cd/1000lm

Angle

90

400W 400W

400W

45

0

High Pressure Sodium 400W (Reflector: Angle)

Lighting Fixtures

A6 _ A7

Lighting Fixtures

A

catalog_eng-html.html
background image

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

54 

56 

61 

70 

72

74

77

80

83

86

88

90

91

92

93

93

92

92

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

91 

89 

84 

75 

64 

51 

36 

22 

10

0

-

-

-

-

-

-

-

Angle

Angle

cd/1000 lm

cd/1000 lm

LEU Series - Ex d II C IP66  

Lighting Fixture

Ex d II C IP66

IEC 60079-0, 1

IEC 60529 

Photometric Data

Mercury Vapor, Metal Halide 175W (Reflector: Non)

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

166

168

173

176

177

174

170

165

161

156

151

142

122 

93

61

35 

17

7

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

















-

Angle

Angle

cd/1000 lm

cd/1000 lm

Mercury Vapor, Metal Halide 175W (Reflector: Dome)

180
175
165
155
145
135
125
115
105

95
90
85
75
65
55
45
35
25
15

5
0

-

0.29
0.21


-

0.14

-

0.29

-

-
-

2.29

21.43
65.36

122.64
151.14
157.71
161.50
163.93
154.36
151.36

-
-
-
-
-
-
-
-

5.14

30.86
45.43
62.36

119.64
157.93
171.79
181.79
186.43
180.14
170.43
157.93
151.36

-
-
-
-
-
-
-

3.50

18.79
60.36
81.86

103.71
148.36
172.29
185.00
193.64
191.29
183.21
171.57
156.00
151.36

Reflector

cd/1000lm cd/1000lm cd/1000lm

Angle

90

175W 175W

175W

45

0

Mercury Vapor, Metal Halide 175W (Reflector: Angie)

Lighting Fixtures

A

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.88 .88 .88 .88 .83 .83 .83 .83 .73 .73 .73 .65 .65 .65 .57 .57 .57  .54

.76 .70 .65 .61 .71 .66 .61 .57 .58 .54 .51 .50 .48 .45 .44 .41 .39  .36

.67 .59 .52 .46 .62 .55 .49 .43 .48 .43 .39 .42 .38 .34 .36 .33 .30  .26

.60 .50 .42 .36 .56 .47 .40 .34 .41 .35 .30 .35 .31 .27 .30 .26 .23  .20

.54 .44 .36 .30 .51 .41 .34 .28 .36 .30 .25 .31 .26 .22 .26 .22 .19  .16

.49 .38 .30 .24 .46 .36 .28 .23 .31 .25 .21 .27 .22 .18 .23 .19 .16  .13

.45 .34 .26 .20 .42 .31 .24 .19 .27 .22 .17 .24 .19 .15 .20 .16 .13  .11

.41 .30 .22 .17 .38 .28 .21 .16 .24 .18 .14 .21 .16 .12 .18 .14 .11  .09

.38 .27 .20 .15 .35 .25 .18 .14 .22 .16 .12 .19 .14 .11 .16 .12 .09  .07

.35 .24 .17 .13 .33 .23 .16 .12 .20 .14 .11 .17 .13 .09 .15 .11 .08  .06

.33 .22 .15 .11 .31 .21 .15 .10 .18 .13 .09 .16 .11 .08 .14 .10 .07  .05

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.77 .77 .77 .77 .75 .75 .75 .75 .71 .71 .71 .68 .68 .68 .65 .65 .65  .64

.70 .68 .65 .63 .69 .66 .64 .61 .63 .61 .59 .60 .59 .57 .58 .57 .55  .54

.64 .59 .55 .52 .63 .58 .54 .51 .55 .52 .50 .53 .51 .48 .51 .49 .47  .46

.59 .52 .47 .43 .57 .51 .46 .42 .49 .45 .42 .47 .44 .41 .45 .42 .40  .38

.54 .46 .41 .36 .52 .45 .40 .36 .43 .39 .35 .42 .38 .35 .40 .37 .34  .33

.49 .41 .35 .31 .48 .40 .34 .31 .38 .34 .30 .37 .33 .30 .36 .32 .29  .28

.45 .36 .30 .26 .43 .35 .30 .26 .34 .29 .26 .33 .29 .25 .32 .28 .25  .24

.41 .32 .26 .22 .40 .31 .26 .22 .30 .25 .22 .29 .25 .21 .28 .24 .21  .20

.38 .29 .23 .19 .37 .28 .23 .19 .27 .22 .19 .26 .22 .19 .26 .22 .19  .17

.35 .26 .20 .17 .34 .26 .20 .17 .25 .20 .17 .24 .19 .16 .23 .19 .16  .15

.32 .24 .18 .15 .31 .23 .18 .15 .22 .18 .15 .22 .17 .14 .21 .17 .14  .13

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.75 .75 .75 .75 .73 .73 .73 .73 .69 .69 .69 .66 .67 .66 .62 .62 .62  .61

.68 .64 .61 .58 .66 .63 .60 .57 .59 .57 .55 .56 .54 .53 .54 .52 .51  .46

.61 .56 .51 .47 .60 .54 .50 .47 .52 .48 .45 .49 .46 .44 .47 .44 .42  .41

.56 .49 .43 .39 .54 .48 .43 .39 .45 .41 .38 .43 .40 .37 .41 .38 .36  .34

.51 .43 .38 .33 .50 .42 .37 .33 .40 .36 .32 .39 .35 .32 .37 .34 .31  .29

.47 .39 .33 .28 .45 .38 .32 .28 .36 .31 .28 .34 .30 .27 .33 .29 .26  .25

.43 .34 .29 .24 .42 .34 .28 .24 .32 .27 .24 .31 .27 .23 .30 .26 .23  .24

.39 .31 .25 .21 .28 .30 .25 .21 .29 .24 .20 .27 .23 .20 .26 .23 .20  .18

.37 .28 .22 .18 .35 .27 .22 .18 .25 .21 .18 .25 .21 .17 .24 .20 .17  .16

.34 .25 .20 .16 .33 .25 .19 .16 .23 .19 .16 .23 .18 .15 .22 .18 .15  .14

.31 .23 .17 .14 .30 .22 .17 .14 .21 .17 .14 .21 .16 .13 .20 .16 .13  .12

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

catalog_eng-html.html
background image

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

23

24

29

33

36

38

41

49

70

84

85

84

85

88

92

94

95

96

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

98

100

101

101

99

94

85

66

40

16

4

0

-

-

-

-

-

Angle

Angle

cd/1000 lm

cd/1000 lm

Photometric Data

Mercury Vapor, Metal Halide 400W (Reflector: Non)

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

140

142

146

147

146

144

140

141

155

162

155

146

140

134

124

89

38

12

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

3

3

2

3

6

8

7

4

Angle

Angle

cd/1000 lm

cd/1000 lm

Mercury Vapor, Metal Halide 400W (Reflector: Dome)

180
175
165
155
145
135
125
115
105

95
90
85
75
65
55
45
35
25
15

5
0

-
-
-
-
-
-
-
-

0.22
1.33
2.36
6.31

34.39

115.42
140.44
152.61
127.92
126.94
133.14
128.28
127.64

-
-
-
-
-
-
-

0.67
9.36

55.64
91.31

124.31
159.03
172.17
180.47
194.81
165.14
152.00
148.14
136.64
127.64

-
-
-
-
-
-
-

4.53

36.00

112.56
144.56
155.17
182.14
190.17
196.75
206.69
181.67
164.86
153.25
137.19
127.64

Reflector

cd/1000lm cd/1000lm cd/1000lm

Angle

90

400W 400W

400W

45

0

Mercury Vapor, Metal Halide 400W (Reflector: Angle)

Lighting Fixtures

A8 _ A9

Lighting Fixtures

A

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.97 .97 .97 .97 .90 .90 .90 .90 .78 .78 .78 .66 .66 .66 .56 .56 .56  .51

.83 .76 .71 .66 .76 .71 .66 .61 .60 .56 .52 .50 .47 .44 .41 .38 .36  .32

.73 .63 .55 .49 .67 .58 .51 .45 .49 .43 .38 .40 .36 .32 .32 .29 .26  .22

.65 .54 .45 .38 .59 .49 .41 .35 .41 .35 .30 .33 .29 .24 .26 .23 .19  .15

.59 .46 .37 .31 .54 .43 .35 .28 .36 .29 .24 .29 .24 .20 .23 .19 .15  .12

.53 .40 .31 .25 .48 .37 .29 .23 .31 .24 .19 .25 .20 .16 .20 .15 .12  .09

.48 .35 .27 .21 .44 .32 .25 .19 .27 .21 .16 .22 .17 .13 .17 .13 .10  .07

.44 .31 .23 .17 .40 .29 .21 .16 .24 .17 .13 .19 .14 .10 .15 .11 .08  .05

.41 .28 .20 .14 .37 .26 .18 .13 .21 .15 .11 .18 .12 .09 .14 .10 .06  .04

.38 .25 .18 .12 .34 .23 .16 .11 .19 .13 .09 .16 .11 .07 .12 .08 .05  .03

.35 .23 .15 .11 .32 .21 .14 .10 .18 .12 .08 .14 .10 .06 .11 .07 .04  .03

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.86 .86 .86 .86 .84 .84 .84 .84 .80 .80 .80 .76 .76 .76 .72 .72 .72 .71

.78 .74 .70 .67 .75 .72 .69 .66 .68 .66 .63 .65 .63 .61 .62 .61 .59 .57

.70 .63 .58 .53 .68 .61 .56 .52 .58 .54 .51 .56 .52 .49 .53 .50 .48 .46

.62 .54 .47 .42 .60 .53 .47 .42 .50 .45 .41 .48 .44 .40 .46 .42 .39 .37

.57 .47 .40 .35 .55 .46 .40 .35 .44 .38 .34 .42 .37 .33 .40 .36 .33 .31

.52 .41 .34 .29 .50 .40 .34 .29 .38 .33 .28 .37 .32 .28 .35 .31 .27 .25

.47 .36 .29 .24 .45 .35 .29 .24 .34 .28 .24 .32 .27 .23 .31 .26 .23 .21

.43 .32 .25 .20 .41 .31 .25 .20 .30 .24 .20 .29 .23 .19 .28 .23 .19 .17

.39 .29 .22 .17 .38 .28 .22 .17 .27 .21 .17 .26 .21 .17 .25 .20 .16 .15

.36 .26 .19 .15 .35 .25 .19 .15 .24 .19 .15 .23 .18 .14 .22 .18 .14 .13

.34 .23 .17 .13 .33 .23 .17 .13 .22 .16 .13 .21 .16 .12 .20 .16 .12 .11

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.82 .82 .82 .82 .80 .80 .80 .80 .75 .75 .75 .71 .71 .71 .67 .67 .67 .65

.73 .69 .65 .62 .71 .67 .63 .60 .63 .60 .57 .59 .57 .55 .56 .54 .52 .50

.66 .59 .54 .49 .63 .57 .52 .48 .54 .50 .46 .51 .47 .44 .48 .45 .42 .40

.59 .51 .44 .39 .57 .49 .43 .39 .47 .41 .37 .44 .40 .36 .41 .38 .35 .33

.54 .45 .38 .33 .52 .44 .37 .32 .41 .36 .31 .39 .34 .30 .37 .33 .29 .28

.49 .39 .33 .27 .47 .38 .32 .27 .36 .31 .26 .34 .29 .26 .32 .28 .25 .23

.45 .35 .28 .23 .43 .34 .27 .23 .32 .26 .22 .30 .25 .22 .29 .24 .21 .19

.41 .31 .24 .20 .40 .30 .24 .19 .28 .23 .19 .27 .22 .18 .25 .21 .18 .16

.38 .28 .21 .17 .36 .27 .21 .17 .25 .20 .16 .24 .19 .16 .23 .19 .15  .14

.35 .25 .19 .14 .34 .24 .18 .14 .23 .18 .14 .22 .17 .13 .21 .16 .13  .12

.32 .22 .16 .12 .31 .22 .16 .12 .21 .16 .12 .20 .15 .12 .19 .14 .11  .10

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

catalog_eng-html.html
background image

15

25

35

45

55

65

75

85

90

95

105

115

125

135

182

165

150

139

107

69

38

6

38

40 

61

90

139

173

191

191

Angle

Angle

cd/1000 lm

cd/1000 lm

15

25

35

45

55

65

75

85

90

95

105

115

125

135

101

20

3

-

-

-

-

-

266

269

248

248

274

280

254

185

Angle

Angle

cd/1000 lm

cd/1000 lm

LEU Series - Ex d II C IP66  

Lighting Fixture

Ex d II C IP66

IEC 60079-0, 1

IEC 60529 

Photometric Data

Fluorescent 30W (Reflector: Non)

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.52 .52 .52 .52 .51 .51 .51 .51 .49 .49 .49 .47 .47 .47 .45 .45 .45  .44

.48 .45 .43 .42 .46 .44 .43 .41 .42 .41 .40 .41 .39 .38 .39 .38 .37  .36

.43 .39 .36 .33 .42 .38 .36 .33 .37 .34 .32 .35 .33 .32 .34 .32 .31  .30

.39 .34 .30 .27 .38 .33 .30 .27 .32 .29 .26 .31 .28 .26 .30 .27 .26  .25

.35 .30 .26 .23 .34 .29 .26 .23 .28 .25 .22 .27 .24 .22 .26 .24 .22  .21

.32 .26 .22 .19 .31 .26 .22 .19 .25 .21 .19 .24 .21 .18 .23 .20 .18  .17

.29 .23 .19 .16 .28 .23 .19 .16 .22 .18 .16 .21 .18 .15 .20 .18 .15  .14

.27 .20 .16 .13 .26 .20 .16 .13 .19 .16 .13 .19 .15 .13 .18 .15 .13  .12

.25 .18 .14 .11 .24 .18 .14 .11 .17 .14 .11 .17 .13 .11 .16 .13 .11  .10

.23 .16 .12 .10 .22 .16 .12 .10 .15 .12 .10 .15 .12 .10 .14 .12 .09  .09

.21 .15 .11 .08 .20 .14 .11 .08 .14 .11 .08 .13 .10 .08 .13 .10 .08  .07

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.50 .50 .50 .50 .48 .48 .48 .48 .44 .44 .44 .40 .40 .40 .36 .36 .36  .35

.44 .41 .38 .36 .41 .39 .36 .34 .35 .33 .31 .32 .30 .29 .28 .27 .26  .24

.39 .34 .30 .27 .37 .32 .29 .26 .29 .26 .24 .26 .24 .22 .23 .22 .20  .18

.35 .29 .25 .21 .33 .28 .24 .20 .25 .22 .19 .22 .20 .17 .20 .18 .16  .14

.31 .25 .21 .17 .30 .24 .20 .17 .22 .18 .15 .19 .17 .14 .17 .15 .13  .12

.28 .22 .18 .14 .27 .21 .17 .14 .19 .15 .13 .17 .14 .12 .15 .13 .11  .09

.26 .19 .15 .12 .24 .18 .14 .11 .17 .13 .11 .15 .12 .10 .13 .11 .09  .08

.24 .17 .13 .10 .22 .16 .12 .10 .15 .11 .09 .13 .10 .08 .12 .09 .07  .06

.22 .15 .11 .08 .21 .15 .11 .08 .13 .10 .08 .12 .09 .07 .11 .08 .06  .05

.20 .14 .10 .07 .19 .13 .10 .07 .12 .09 .06 .11 .08 .06 .10 .07 .05  .04

.19 .13 .09 .06 .18 .12 .08 .06 .11 .08 .06 .10 .07 .05 .09 .06 .05  .04

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

Fluorescent 30W (Reflector: Dome)

ZONAL CAVITY METHOD

0
5

15
25
35
45
55
65
75
85
90
95

105
115
125
135
145
155

104

78

101
153
234
306
350
364
355
326
306
280
222
156

92
35

3

-

0
5

15
25
35
45
55
65
75
85
90
95

105
115
125
135
145
155

104
107
133
168
202
234
234
196
173
150
133
118

87
55
23

-
-
-

FRONT

SIDE

cd/1000lm cd/1000lm cd/1000lm

Angle

Fluorescent 30W (Reflector: Angle)

ZONAL CAVITY METHOD

Lighting Fixtures

A

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.60 .60 .60 .60 .57 .57 .57 .57 .51 .51 .51 .46 .46 .46 .41 .41 .41  .39

.52 .48 .44 .41 .49 .45 .42 .39 .40 .38 .35 .36 .34 .32 .31 .30 .28  .26

.45 .40 .35 .31 .43 .37 .33 .29 .33 .29 .26 .29 .26 .24 .25 .23 .21  .19

.40 .33 .28 .24 .38 .31 .26 .22 .28 .24 .20 .24 .21 .18 .21 .18 .16  .14

.37 .29 .23 .19 .34 .27 .22 .18 .24 .20 .16 .21 .17 .14 .18 .15 .13  .11

.33 .25 .19 .15 .31 .23 .18 .14 .21 .16 .13 .18 .14 .11 .16 .12 .10  .08

.30 .22 .16 .12 .28 .20 .15 .12 .18 .14 .10 .16 .12 .09 .13 .10 .08  .06

.27 .19 .14 .10 .25 .18 .13 .10 .16 .12 .08 .14 .10 .07 .12 .09 .06  .05

.25 .17 .12 .08 .23 .16 .11 .08 .14 .10 .07 .12 .09 .06 .11 .08 .05  .04

.23 .15 .10 .07 .22 .14 .10 .07 .13 .09 .06 .11 .08 .05 .09 .06 .04  .03

.21 .14 .09 .06 .20 .13 .09 .06 .11 .08 .05 .10 .07 .04 .08 .06 .04  .02

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

catalog_eng-html.html
background image

LNS Series - Ex nR II IP66  

Lighting Fixture

Ex d II IP66

IEC 60079-0, 15

IEC 60529 

Applications

LNS Series Lighting Fixtures are designed for installations where moisture, dirt, dust, corrosion 

and vibration may be present, or IEC 60529 IP66 areas where wind, water, snow or high ambient 
can be expected.

They can be used in locations made hazardous due to the presence of flammable or explosive 

gases, vapors and combustible dusts as defined by the IEC 60079-0,15.

Applications include classified areas such as paint manufacturing plants, ammunition facilities, 

oil and gas producing and refining plants, off-shore and dockside installations, tank farms, 
pipeline pumping stations and marine loading and fuel transfer terminals.

Hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired.

Features

Wide range of light sources and wattages to meet specific lighting needs-30 and 85 Fluorescent; 100, 150,

250 and 400W high pressure sodium (HPS) ; 250 and 400W mercury vapor (MV); 175, 250 and 400W metal
halide (MH).

Four light sources – Compact fluorescent, high pressure sodium, metal halide and mercury vapor.

Mounting choice – Pendant,Ceiling, 25

°

Stanchion, 40

°

or 90

°

wall mount

Integral ballasts – separate ballasts are not required. Lowest installed cost.

Corrosion resistant – Copper-free aluminum die cast construction. Baked powder epoxy finish, 
electro-statically applies Exposed hardware is stainless steel.

Pendant type is standard.

Standard Materials

Copper-free Aluminium (Cast Aluminium Alloy)

Globe : Heat Resistant Glass

Reflector : High Purity Aluminium 

Guard & Accessory : Stainless Steel

Options

Fuse – to protect ballast and capacitors against

abnormal line conditions.

One fuse required for 120 or 277VAC units

Two fuses needed for 208, 240 or 480VAC units

Instant re-strike ballast – enables a hot HPS

lamp to immediately re-strike after a momentary
loss of arc due to voltage fluctuation or power
outage. It has no effect on the warm-up period of
cold lamps (Max 150W HPS only).

Dome reflector or 30

°

angle reflector.

Protect Guard.

High power factor – Minimum P. F. 90%.

Technical Data

Voltage Range - AC 100V~480V

Watts Range - 30~400W

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Certification

Certified by KOSHA

(Korea Occupational Safety & Health Agency)

Weight

16 kg 

Compliances

IEC 60079-0 Equipment – General requirements

IEC 60079-15 Coustruction, test and marking of
type of protection “n” electrical apparatus

ANSI /ASME B 1.20.1 Pipe threads, General 

purpose (Inch)

ISO 228/1  Pipe threads where pressure-tight 
joints are not made on the threads

ISO 261 Metric screw thread

Lighting Fixtures

A10 _ A11

Lighting Fixtures

A

catalog_eng-html.html
background image

Model Number Logic

Lamp Type

C-Fluorescent
S-HPS (High
pressure sodium)
M-Metal
V-Mercury

Series 
Constant 

LNS

0

Lamp Wattage

03- 30W-C
08- 85W-C
10-100W-S
15-150W-S
17-175W-M
25-250W-M.S.V
40-400W-M.S.V

00

Voltage

@

60Hz

12-AC120V
20-AC208V
22-AC220V
24-AC-240V
27-AC277V
48-AC480V 

00

Mounting Type

PT-Pendant
CL-Ceiling
ST-Stanchion
4B-40

°

Bracket

9B-90

°

Bracket

00

0

ex) High Pressure Sodium, Normal type 90

°

Bracket Mounting, AC277V, 400W, No guard

G-Omit G if guard

is not required

0

P-Omit P if High
powerfactor 
is not required

LNS Series - Ex nR II IP66  

Lighting Fixture

Ex nR II IP66

IEC 60079-0, 15

IEC 60529 

Lighting Fixtures

A

Dimensions

40° Wall Mount Type

90° Wall Mount Type

Standard Type Reflector

30° Dome Type Reflector

Ceiling Type

Stanchion Type

Pendant Type

Dimensions (mm) 

catalog_eng-html.html
background image

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

19

21

25

34

42

47 

53 

55 

55 

55 

66 

77 

88 

96 

98 

100 

102 

106

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

107

107

103

97

77

43

11

1

0

0

-

-

-

-

-

-

-

-

Angle

Angle

cd/1000 lm

cd/1000 lm

Photometric Data

High Pressure Sodium 100W (Reflector: Non)

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

126

128

133

142

143

143

139

133

126

121

126

129

131

100 

49 

26 

14 

5

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

1
5

10

9
3










-
-
-

Angle

Angle

cd/1000 lm

cd/1000 lm

High Pressure Sodium 100W (Reflector: Dome)

180
175
165
155
145
135
125
115
105

95
90
85
75
65
55
45
35
25
15

5
0

-
-
-
-
-
-
-
-

5.37

20.63
32.63
60.84

148.95
161.05
159.05
151.47
156.21
146.53
135.26
118.74
114.63

-
-
-
-
-
-
-
-
-
-
-

2.00

18.53
54.32

122.74
116.21
131.79
133.47
127.05
114.63 
114.63

-
-
-
-
-
-
-

3.16

15.37
45.79
84.53

119.47
173.58
181.26
172.42
164.42
157.89
149.58
134.84
120.84
114.63

Reflector

cd/1000lm cd/1000lm cd/1000lm

Angle

90

100W 100W

100W

45

0

High Pressure Sodium 100W (Reflector: Angle)

Lighting Fixtures

A12 _ A13

Lighting Fixtures

A

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.84 .84 .84 .84 .79 .79 .79 .79 .70 .70 .70 .61 .61 .61 .53 .53 .53 .50

.71 .66 .61 .56 .66 .61 .57 .52 .53 .49 .46 .46 .43 .40 .39 .36 .34 .31

.64 .54 .47 .41 .58 .50 .44 .38 .43 .38 .34 .37 .33 .29 .31 .27 .25 .21

.56 .46 .38 .32 .51 .42 .35 .30 .36 .30 .26 .30 .26 .22 .25 .22 .18 .15

.50 .40 .32 .26 .46 .37 .30 .24 .31 .25 .21 .26 .22 .18 .22 .18 .15 .12

.46 .34 .27 .21 .42 .32 .25 .19 .27 .21 .17 .23 .18 .14 .19 .15 .12 .09

.42 .30 .23 .17 .38 .28 .21 .16 .24 .18 .14 .20 .15 .12 .17 .12 .09 .07

.38 .27 .19 .14 .35 .25 .18 .13 .21 .15 .11 .18 .13 .09 .15 .11 .08 .06

.35 .24 .17 .12 .32 .22 .16 .11 .19 .14 .10 .16 .11 .08 .13 .09 .06 .05

.33 .22 .15 .10 .30 .20 .14 .10 .17 .12 .08 .15 .10 .07 .12 .08 .05 .04

.30 .20 .13 .09 .28 .18 .12 .08 .16 .11 .07 .13 .09 .06 .11 .07 .05 .03

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.66 .66 .66 .66 .64 .64 .64 .64 .61 .61 .61 .58 .58 .58 .56 .56 .56 .54

.61 .58 .56 .54 .59 .57 .55 .53 .54 .52 .51 .52 .50 .49 .49 .48 .47 .46

.55 .51 .47 .44 .54 .50 .46 .43 .47 .45 .42 .46 .43 .41 .44 .42 .40 .39

.50 .44 .40 .36 .49 .43 .39 .36 .42 .38 .35 .40 .37 .34 .38 .36 .34 .32

.46 .39 .34 .31 .45 .38 .34 .30 .37 .33 .30 .35 .32 .29 .34 .31 .29 .27

.42 .34 .29 .26 .40 .34 .29 .25 .32 .28 .25 .31 .27 .24 .30 .27 .24 .23

.38 .30 .25 .22 .37 .30 .25 .21 .29 .24 .21 .27 .24 .21 .26 .23 .20 .19

.35 .27 .22 .18 .34 .26 .21 .18 .25 .21 .18 .24 .20 .17 .23 .20 .17 .16

.32 .24 .19 .16 .31 .24 .19 .16 .23 .18 .15 .22 .18 .15 .21 .18 .15 .14

.33 .22 .17 .14 .29 .21 .17 .14 .21 .16 .13 .20 .16 .13 .19 .16 .13 .12

.27 .20 .15 .12 .27 .19 .15 .12 .19 .15 .12 .18 .14 .12 .17 .14 .11 .10

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.68 .68 .68 .68 .66 .66 .66 .66 .62 .62 .62 .59 .59 .59 .56 .56 .56 .55

.60 .57 .54 .51 .58 .56 .53 .50 .52 .50 .48 .50 .48 .46 .47 .46 .44 .43

.54 .49 .45 .41 .53 .48 .44 .40 .45 .42 .39 .43 .40 .37 .41 .38 .36 .35

.49 .42 .37 .33 .47 .41 .36 .33 .39 .35 .32 .37 .34 .31 .35 .32 .30 .28

.45 .38 .32 .28 .43 .37 .32 .28 .35 .30 .27 .33 .29 .26 .31 .28 .26 .24

.41 .33 .23 .23 .40 .32 .27 .23 .31 .26 .23 .29 .25 .22 .28 .25 .22 .20

.38 .29 .24 .20 .36 .29 .24 .20 .27 .23 .19 .26 .22 .19 .25 .21 .19 .17

.34 .26 .21 .17 .33 .26 .20 .17 .24 .20 .17 .23 .19 .16 .22 .19 .16 .15

.32 .24 .18 .15 .31 .23 .18 .15 .22 .18 .14 .21 .17 .14 .20 .17 .14 .13

.29 .21 .16 .13 .28 .21 .16 .13 .20 .16 .13 .19 .15 .12 .18 .15 .12 .11

.27 .19 .14 .11 .26 .19 .14 .11 .18 .14 .11 .17 .13 .11 .17 .13 .11 .10

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

catalog_eng-html.html
background image

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

17 

17 

22 

30 

35 

38 

41 

45 

59 

70 

79 

86 

92 

96 

100 

104 

106 

107

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

107

106

104

101

96

88

75

57

37

19

7

2

0

-

-

-

-

-

Angle

Angle

cd/1000 lm

cd/1000 lm

Photometric Data

High Pressure Sodium 400W (Reflector: Non)

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

119

119 

123 

129

132 

132

130

129

137

142

146

147 

146

143

136

108

75 

39

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

9

5

3

4

5

6

5

4

2

Angle

Angle

cd/1000 lm

cd/1000 lm

High Pressure Sodium 400W (Reflector: Dome)

180
175
165
155
145
135
125
115
105

95
90
85
75
65
55
45
35
25
15

5
0

-
-
-
-
-
-
-

1.94

21.48
79.90

110.44
138.56
172.12
180.62
180.98
170.28
149.24
143.10
131.12
112.46
108.60

-
-
-
-
-
-
-

0.08
0.50
2.36
3.88

11.88
71.56

129.84 
142.46
136.74
118.32
121.50
118.50
107.64
108.60

-
-
-
-
-
-

0.54

10.98
53.26

114.98
143.54
155.78
175.92
183.70
189.14
184.44
160.14
146.92
134.40
114.44
108.60

Reflector

cd/1000lm cd/1000lm cd/1000lm

Angle

90

400W 400W

400W

45

0

High Pressure Sodium 400W (Reflector: Angle)

LNS Series - Ex nR II IP66  

Lighting Fixture

Ex nR II IP66

IEC 60079-0, 15

IEC 60529 

Lighting Fixtures

A

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.97 .97 .97 .97 .90 .90 .90 .90 .78 .78 .78 .66 .66 .66 .56 .56 .56  .51

.83 .76 .71 .66 .76 .71 .66 .61 .60 .56 .52 .50 .47 .44 .41 .38 .36 .32

.73 .63 .55 .49 .67 .58 .51 .45 .49 .43 .38 .40 .36 .32 .32 .29 .26 .22

.65 .54 .45 .38 .59 .49 .41 .35 .41 .35 .30 .33 .29 .24 .26 .23 .19 .15

.59 .46 .37 .31 .54 .43 .35 .28 .36 .29 .24 .29 .24 .20 .23 .19 .15 .12

.53 .40 .31 .25 .48 .37 .29 .23 .31 .24 .19 .25 .20 .16 .20 .15 .12 .09

.48 .35 .27 .21 .44 .32 .25 .19 .27 .21 .16 .22 .17 .13 .17 .13 .10 .07

.44 .31 .23 .17 .40 .29 .21 .16 .24 .17 .13 .19 .14 .10 .15 .11 .08 .05

.41 .28 .20 .14 .37 .26 .18 .13 .21 .15 .11 .18 .12 .09 .14 .10 .06 .04

.38 .25 .18 .12 .34 .23 .16 .11 .19 .13 .09 .16 .11 .07 .12 .08 .05 .03

.35 .23 .15 .11 .32 .21 .14 .10 .18 .12 .08 .14 .10 .06 .11 .07 .04 .03

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.89 .89 .89 .89 .87 .87 .87 .87 .82 .82 .82 .78 .78 .78 .75 .75 .75 .73

.79 .74 .70 .67 .77 .73 .69 .65 .69 .66 .63 .65 .63 .60 .62 .60 .58 .56

.70 .63 .57 .51 .68 .61 .55 .50 .58 .53 .49 .55 .51 .47 .52 .49 .46 .44

.63 .53 .46 .40 .60 .52 .45 .40 .49 .43 .39 .47 .42 .38 .44 .40 .37 .35

.57 .46 .39 .33 .55 .45 .38 .33 .43 .37 .32 .41 .36 .31 .39 .34 .31 .29

.51 .40 .33 .27 .49 .39 .32 .27 .37 .31 .26 .36 .30 .26 .34 .29 .25 .23

.47 .35 .28 .22 .45 .35 .27 .22 .33 .27 .22 .31 .26 .21 .30 .25 .21 .19

.43 .31 .24 .19 .41 .30 .23 .18 .29 .23 .18 .28 .22 .18 .27 .21 .17 .16

.39 .28 .21 .16 .38 .27 .21 .16 .26 .20 .16 .25 .19 .15 .24 .19 .15 .13

.36 .25 .18 .14 .35 .25 .18 .14 .24 .18 .13 .23 .17 .13 .22 .17 .13 .11

.34 .23 .16 .12 .33 .22 .16 .12 .21 .16 .12 .21 .15 .11 .20 .15 .11 .10

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.84 .84 .84 .84 .81 .81 .81 .81 .76 .76 .76 .72 .72 .72 .67 .67 .67 .65

.74 .69 .65 .62 .71 .67 .63 .60 .63 .60 .57 .59 .56 .54 .55 .53 .51 .49

.66 .59 .53 .48 .64 .57 .51 .47 .53 .49 .45 .50 .46 .43 .47 .44 .41 .39

.59 .50 .44 .38 .57 .49 .43 .37 .46 .40 .36 .43 .38 .34 .40 .36 .33 .31

.54 .44 .37 .32 .52 .43 .36 .31 .40 .34 .30 .38 .33 .29 .35 .31 .28 .26

.49 .39 .32 .26 .47 .38 .31 .26 .35 .29 .25 .33 .28 .24 .31 .27 .23 .21

.45 .34 .27 .22 .43 .33 .26 .22 .31 .25 .21 .29 .24 .20 .27 .23 .19 .18

.41 .30 .23 .19 .39 .29 .23 .18 .27 .22 .17 .26 .21 .17 .24 .20 .16 .15

.38 .27 .20 .16 .36 .26 .20 .15 .25 .19 .15 .23 .18 .14 .22 .17 .14 .12

.35 .24 .18 .13 .33 .24 .18 .13 .22 .17 .13 .21 .16 .12 .20 .15 .12 .11

.32 .22 .16 .12 .31 .21 .16 .12 .20 .15 .11 .19 .14 .11 .18 .14 .10 .09

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

catalog_eng-html.html
background image

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

54

56

61

70

72

74

77

80

83

86

88

90

91

92

93

93

92

92

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

91

89

84

75

64

51

36

22

10

2

0

-

-

-

-

-

-

-

Angle

Angle

cd/1000 lm

cd/1000 lm

Photometric Data

Mercury Vapor, Metal Halide 175W (Reflector: Non)

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

166

168

173

176 

177

174 

170 

165

161

156

151

142

122

93

61

35

17

7

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

2
3
4
5
5
3
1
0








-
-
-

Angle

Angle

cd/1000 lm

cd/1000 lm

Mercury Vapor, Metal Halide 175W (Reflector: Dome)

180
175
165
155
145
135
125
115
105

95
90
85
75
65
55
45
35
25
15

5
0


-

-
-
-


5.14

30.86
45.43
62.36

119.64
157.93
171.79
181.79
186.43
180.14
170.43
157.93
151.36

0.29 
0.21 

-

0.14 

0.29 

-

-

2.29

21.43 
65.36 

122.64 
151.14 
157.71 
161.50
163.93
154.36
151.36

-
-
-
-
-
-
-

3.50

18.79
60.36
81.86

103.71
148.36
172.29
185.00
193.64
191.29
183.21
171.57
156.00
151.36

Reflector

cd/1000lm cd/1000lm cd/1000lm

Angle

90

175W 175W

175W

45

0

Mercury Vapor, Metal Halide 175W (Reflector: Angle)

Lighting Fixtures

A14 _ A15

Lighting Fixtures

A

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.88 .88 .88 .88 .83 .83 .83 .83 .73 .73 .73 .65 .65 .65 .57 .57 .57 .54

.76 .70 .65 .61 .71 .66 .61 .57 .58 .54 .51 .50 .48 .45 .44 .41 .39 .36

.67 .59 .52 .46 .62 .55 .49 .43 .48 .43 .39 .42 .38 .34 .36 .33 .30 .26

.60 .50 .42 .36 .56 .47 .40 .34 .41 .35 .30 .35 .31 .27 .30 .26 .23 .20

.54 .44 .36 .30 .51 .41 .34 .28 .36 .30 .25 .31 .26 .22 .26 .22 .19 .16

.49 .38 .30 .24 .46 .36 .28 .23 .31 .25 .21 .27 .22 .18 .23 .19 .16 .13

.45 .34 .26 .20 .42 .31 .24 .19 .27 .22 .17 .24 .19 .15 .20 .16 .13 .11

.41 .30 .22 .17 .38 .28 .21 .16 .24 .18 .14 .21 .16 .12 .18 .14 .11 .09

.38 .27 .20 .15 .35 .25 .18 .14 .22 .16 .12 .19 .14 .11 .16 .12 .09 .07

.35 .24 .17 .13 .33 .23 .16 .12 .20 .14 .11 .17 .13 .09 .15 .11 .08 .06

.33 .22 .15 .11 .31 .21 .15 .10 .18 .13 .09 .16 .11 .08 .14 .10 .07 .05

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.77 .77 .77 .77 .75 .75 .75 .75 .71 .71 .71 .68 .68 .68 .65 .65 .65 .64

.70 .68 .65 .63 .69 .66 .64 .61 .63 .61 .59 .60 .59 .57 .58 .57 .55 .54

.64 .59 .55 .52 .63 .58 .54 .51 .55 .52 .50 .53 .51 .48 .51 .49 .47 .46

.59 .52 .47 .43 .57 .51 .46 .42 .49 .45 .42 .47 .44 .41 .45 .42 .40 .38

.54 .46 .41 .36 .52 .45 .40 .36 .43 .39 .35 .42 .38 .35 .40 .37 .34 .33

.49 .41 .35 .31 .48 .40 .34 .31 .38 .34 .30 .37 .33 .30 .36 .32 .29 .28

.45 .36 .30 .26 .43 .35 .30 .26 .34 .29 .26 .33 .29 .25 .32 .28 .25 .24

.41 .32 .26 .22 .40 .31 .26 .22 .30 .25 .22 .29 .25 .21 .28 .24 .21 .20

.38 .29 .23 .19 .37 .28 .23 .19 .27 .22 .19 .26 .22 .19 .26 .22 .19 .17

.35 .26 .20 .17 .34 .26 .20 .17 .25 .20 .17 .24 .19 .16 .23 .19 .16 .15

.32 .24 .18 .15 .31 .23 .18 .15 .22 .18 .15 .22 .17 .14 .21 .17 .14 .13

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.75 .75 .75 .75 .73 .73 .73 .73 .69 .69 .69 .66 .67 .66 .62 .62 .62 .61

.68 .64 .61 .58 .66 .63 .60 .57 .59 .57 .55 .56 .54 .53 .54 .52 .51 .46

.61 .56 .51 .47 .60 .54 .50 .47 .52 .48 .45 .49 .46 .44 .47 .44 .42 .41

.56 .49 .43 .39 .54 .48 .43 .39 .45 .41 .38 .43 .40 .37 .41 .38 .36 .34

.51 .43 .38 .33 .50 .42 .37 .33 .40 .36 .32 .39 .35 .32 .37 .34 .31 .29

.47 .39 .33 .28 .45 .38 .32 .28 .36 .31 .28 .34 .30 .27 .33 .29 .26 .25

.43 .34 .29 .24 .42 .34 .28 .24 .32 .27 .24 .31 .27 .23 .30 .26 .23 .24

.39 .31 .25 .21 .28 .30 .25 .21 .29 .24 .20 .27 .23 .20 .26 .23 .20 .18

.37 .28 .22 .18 .35 .27 .22 .18 .25 .21 .18 .25 .21 .17 .24 .20 .17 .16

.34 .25 .20 .16 .33 .25 .19 .16 .23 .19 .16 .23 .18 .15 .22 .18 .15 .14

.31 .23 .17 .14 .30 .22 .17 .14 .21 .17 .14 .21 .16 .13 .20 .16 .13 .12

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

catalog_eng-html.html
background image

LNS Series - Ex nR II IP66  

Lighting Fixture

Ex nR II IP66

IEC 60079-0, 15

IEC 60529 

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

23

24

29

33

36

38

41

49

70

84

85

84

85

88

92

94

95

96

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

98

100

101

101

99

94

85

66

40

16

4

0

-

-

-

-

-

-

Angle

Angle

cd/1000 lm

cd/1000 lm

Photometric Data

High Pressure Sodium 400W (Reflector: Non)

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

140

142

146

147

146

144

140

141

155

162

155

146

140

134

124

89 

38 

12

90

95

100

105

110

115

120

125

130

135

140

145

150

155

160

165

170

175

3

3

2

3

6

8

7

4

1

Angle

Angle

cd/1000 lm

cd/1000 lm

High Pressure Sodium 400W (Reflector: Dome)

180
175
165
155
145
135
125
115
105

95
90
85
75
65
55
45
35
25
15

5
0

-
-
-
-
-
-
-

0.67
9.36

55.64
91.31

124.31
159.03
172.17
180.47
194.81
165.14
152.00
148.14
136.64
127.64

-
-
-
-
-
-
-
-

0.22
1.33
2.36
6.31

34.39

115.42
140.44
152.61
127.92
126.94
133.14
128.28
127.64

-
-
-
-
-
-
-

4.53

36.00

112.56
144.56
155.17
182.14
190.17
196.75
206.69
181.67
164.86
153.25
137.19
127.64

Reflector

cd/1000lm cd/1000lm cd/1000lm

Angle

90

400W 400W

400W

45

0

Mercury Vapor, Metal Halide 400W (Reflector: Angle)

Lighting Fixtures

A

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.95 .95 .95 .95 .88 .88 .88 .88 .76 .76 .76 .65 .65 .65 .54 .54 .54 .49

.82 .76 .70 .66 .75 .70 .65 .61 .59 .55 .52 .49 .46 .44 .40 .38 .36 .31

.72 .63 .56 .49 .66 .58 .51 .46 .49 .43 .39 .40 .36 .32 .32 .29 .23 .22

.64 .54 .45 .39 .59 .49 .42 .36 .41 .35 .30 .34 .29 .25 .27 .23 .20 .16

.58 .47 .38 .31 .53 .43 .35 .29 .36 .29 .25 .29 .24 .20 .23 .19 .16 .13

.53 .40 .32 .26 .48 .37 .29 .24 .31 .25 .20 .25 .20 .16 .20 .16 .13 .10

.48 .36 .27 .21 .44 .33 .25 .19 .27 .21 .16 .22 .17 .13 .17 .13 .10 .07

.44 .31 .23 .18 .40 .29 .21 .16 .24 .18 .13 .19 .14 .11 .15 .11 .08 .06

.40 .28 .20 .15 .37 .26 .19 .14 .21 .16 .11 .18 .13 .09 .14 .10 .07 .05

.37 .25 .18 .13 .34 .23 .16 .12 .19 .14 .10 .16 .11 .08 .12 .08 .06 .04

.35 .23 .16 .11 .32 .21 .14 .10 .18 .12 .08 .14 .10 .06 .11 .07 .05 .03

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.86 .86 .86 .86 .84 .84 .84 .84 .80 .80 .80 .76 .76 .76 .72 .72 .72 .71

.78 .74 .70 .67 .75 .72 .69 .66 .68 .66 .63 .65 .63 .61 .62 .61 .59 .57

.70 .63 .58 .53 .68 .61 .56 .52 .58 .54 .51 .56 .52 .49 .53 .50 .48 .46

.62 .54 .47 .42 .60 .53 .47 .42 .50 .45 .41 .48 .44 .40 .46 .42 .39 .37

.57 .47 .40 .35 .55 .46 .40 .35 .44 .38 .34 .42 .37 .33 .40 .36 .33 .31

.52 .41 .34 .29 .50 .40 .34 .29 .38 .33 .28 .37 .32 .28 .35 .31 .27 .25

.47 .36 .29 .24 .45 .35 .29 .24 .34 .28 .24 .32 .27 .23 .31 .26 .23 .21

.43 .32 .25 .20 .41 .31 .25 .20 .30 .24 .20 .29 .23 .19 .28 .23 .19 .17

.39 .29 .22 .17 .38 .28 .22 .17 .27 .21 .17 .26 .21 .17 .25 .20 .16 .15

.36 .26 .19 .15 .35 .25 .19 .15 .24 .19 .15 .23 .18 .14 .22 .18 .14 .13

.34 .23 .17 .13 .33 .23 .17 .13 .22 .16 .13 .21 .16 .12 .20 .16 .12 .11

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.82 .82 .82 .82 .80 .80 .80 .80 .75 .75 .75 .71 .71 .71 .67 .67 .67 .65

.73 .69 .65 .62 .71 .67 .63 .60 .63 .60 .57 .59 .57 .55 .56 .54 .52 .50

.66 .59 .54 .49 .63 .57 .52 .48 .54 .50 .46 .51 .47 .44 .48 .45 .42 .40

.59 .51 .44 .39 .57 .49 .43 .39 .47 .41 .37 .44 .40 .36 .41 .38 .35 .33

.54 .45 .38 .33 .52 .44 .37 .32 .41 .36 .31 .39 .34 .30 .37 .33 .29 .28

.49 .39 .33 .27 .47 .38 .32 .27 .36 .31 .26 .34 .29 .26 .32 .28 .25 .23

.45 .35 .28 .23 .43 .34 .27 .23 .32 .26 .22 .30 .25 .22 .29 .24 .21 .19

.41 .31 .24 .20 .40 .30 .24 .19 .28 .23 .19 .27 .22 .18 .25 .21 .18 .16

.38 .28 .21 .17 .36 .27 .21 .17 .25 .20 .16 .24 .19 .16 .23 .19 .15 .14

.35 .25 .19 .14 .34 .24 .18 .14 .23 .18 .14 .22 .17 .13 .21 .16 .13 .12

.32 .22 .16 .12 .31 .22 .16 .12 .21 .16 .12 .20 .15 .12 .19 .14 .11 .10

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

catalog_eng-html.html
background image

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.60 .60 .60 .60 .57 .57 .57 .57 .51 .51 .51 .46 .46 .46 .41 .41 .41  .39

.52 .48 .44 .41 .49 .45 .42 .39 .40 .38 .35 .36 .34 .32 .31 .30 .28  .26

.45 .40 .35 .31 .43 .37 .33 .29 .33 .29 .26 .29 .26 .24 .25 .23 .21  .19

.40 .33 .28 .24 .38 .31 .26 .22 .28 .24 .20 .24 .21 .18 .21 .18 .16  .14

.37 .29 .23 .19 .34 .27 .22 .18 .24 .20 .16 .21 .17 .14 .18 .15 .13  .11

.33 .25 .19 .15 .31 .23 .18 .14 .21 .16 .13 .18 .14 .11 .16 .12 .10  .08

.30 .22 .16 .12 .28 .20 .15 .12 .18 .14 .10 .16 .12 .09 .13 .10 .08  .06

.27 .19 .14 .10 .25 .18 .13 .10 .16 .12 .08 .14 .10 .07 .12 .09 .06  .05

.25 .17 .12 .08 .23 .16 .11 .08 .14 .10 .07 .12 .09 .06 .11 .08 .05  .04

.23 .15 .10 .07 .22 .14 .10 .07 .13 .09 .06 .11 .08 .05 .09 .06 .04  .03

.21 .14 .09 .06 .20 .13 .09 .06 .11 .08 .05 .10 .07 .04 .08 .06 .04  .02

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

15

25

35

45

55

65

75

85

90

95

105

115

125

135

182

165

150

139

107

69

38

6

38

40 

61

90

139

173

191

191

Angle

Angle

cd/1000 lm

cd/1000 lm

15

25

35

45

55

65

75

85

90

95

105

115

125

135

101

20

3

-

-

-

-

-

266

269

248

248

274

280

254

185

Angle

Angle

cd/1000 lm

cd/1000 lm

Photometric Data

Fluorescent 30W (Reflector: Non)

ZONAL CAVITY METHOD

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.52 .52 .52 .52 .51 .51 .51 .51 .49 .49 .49 .47 .47 .47 .45 .45 .45  .44

.48 .45 .43 .42 .46 .44 .43 .41 .42 .41 .40 .41 .39 .38 .39 .38 .37  .36

.43 .39 .36 .33 .42 .38 .36 .33 .37 .34 .32 .35 .33 .32 .34 .32 .31  .30

.39 .34 .30 .27 .38 .33 .30 .27 .32 .29 .26 .31 .28 .26 .30 .27 .26  .25

.35 .30 .26 .23 .34 .29 .26 .23 .28 .25 .22 .27 .24 .22 .26 .24 .22  .21

.32 .26 .22 .19 .31 .26 .22 .19 .25 .21 .19 .24 .21 .18 .23 .20 .18  .17

.29 .23 .19 .16 .28 .23 .19 .16 .22 .18 .16 .21 .18 .15 .20 .18 .15  .14

.27 .20 .16 .13 .26 .20 .16 .13 .19 .16 .13 .19 .15 .13 .18 .15 .13  .12

.25 .18 .14 .11 .24 .18 .14 .11 .17 .14 .11 .17 .13 .11 .16 .13 .11  .10

.23 .16 .12 .10 .22 .16 .12 .10 .15 .12 .10 .15 .12 .10 .14 .12 .09  .09

.21 .15 .11 .08 .20 .14 .11 .08 .14 .11 .08 .13 .10 .08 .13 .10 .08  .07

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

20% Effective Floor Cavity Reflectance

70

.88 .88 .88 .88 .83 .83 .83 .83 .73 .73 .73 .65 .65 .65 .57 .57 .57  .54

.76 .70 .65 .61 .71 .66 .61 .57 .58 .54 .51 .50 .48 .45 .44 .41 .39  .36

.67 .59 .52 .46 .62 .55 .49 .43 .48 .43 .39 .42 .38 .34 .36 .33 .30  .26

.60 .50 .42 .36 .56 .47 .40 .34 .41 .35 .30 .35 .31 .27 .30 .26 .23  .20

.54 .44 .36 .30 .51 .41 .34 .28 .36 .30 .25 .31 .26 .22 .26 .22 .19  .16

.49 .38 .30 .24 .46 .36 .28 .23 .31 .25 .21 .27 .22 .18 .23 .19 .16  .13

.45 .34 .26 .20 .42 .31 .24 .19 .27 .22 .17 .24 .19 .15 .20 .16 .13  .11

.41 .30 .22 .17 .38 .28 .21 .16 .24 .18 .14 .21 .16 .12 .18 .14 .11  .09

.38 .27 .20 .15 .35 .25 .18 .14 .22 .16 .12 .19 .14 .11 .16 .12 .09  .07

.35 .24 .17 .13 .33 .23 .16 .12 .20 .14 .11 .17 .13 .09 .15 .11 .08  .06

.33 .22 .15 .11 .31 .21 .15 .10 .18 .13 .09 .16 .11 .08 .14 .10 .07  .05

50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% EFFECTIVE

Ceiling Cavity

Reflectance 1cc

% Wall

Reflectance 1w

Room Cavity

Ratio RCR

Fluorescent 30W (Reflector: Dome)

ZONAL CAVITY METHOD

0
5

15
25
35
45
55
65
75
85
90
95

105
115
125
135
145
155

104

78

101
153
234
306
350
364
355
326
306
280
222
156

92
35

3

-

0
5

15
25
35
45
55
65
75
85
90
95

105
115
125
135
145
155

104
107
133
168
202
234
234
196
173
150
133
118

87
55
23

-
-
-

FRONT

SIDE

cd/1000lm cd/1000lm cd/1000lm

Angle

Fluorescent 30W (Reflector: Angle)

ZONAL CAVITY METHOD

Lighting Fixtures

A16 _ A17

Lighting Fixtures

A

catalog_eng-html.html
background image

LES Series - Ex d II B IP54  

Lighting Fixture

Ex d II B IP54

IEC 60079-0, 1

IEC 60529 

Applications

LES Series Lighting Fixtures are designed for installations where moisture, dirt, dust, corrosion 

and vibration may be present, or IEC 60529 IP54 areas where wind, water, snow or high ambient 
can be expected.

They can be used in locations made hazardous due to the presence of flammable or explosive 

gases, vapors and combustible dusts as defined by the IEC 60079-0,1.

Applications include classified areas such as paint manufacturing plants, ammunition facilities, 

oil and gas producing and refining plants, off-shore and dockside installations, tank farms,
pipeline pumping stations and marine loading and fuel transfer terminals.

Hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired.

Features

Wide range of light sources and wattages to meet specific lighting needs – 30 and 85 Fluorescent;100,

150, 200, 250 and 400W high pressure sodium (HPS); 250 and 400W mercury vapor (MV); 175, 250 and

400W metal halide (MH).

Four light sources – Compact fluorescent, high pressure sodium, metal halide and mercury vapor.

Mounting choice – Pendant,Ceiling, 25

°

Stanchion, 40

°

or 90

°

wall mount.

Corrosion resistant – Copper-free aluminum die-cast construction. Baked powder epoxy finish,

electro-statically applied. Exposed hardware is stainless steel.

Pendant type is standard.

Standard Materials

Copper-free Aluminium (Cast Aluminium Alloy)

Globe : Heat Resistant Glass

Reflector : High Purity Aluminium 

Guard & Accessory : Stainless Steel

Options

Fuse – to protect ballast and capacitors against

abnormal line conditions.

One fuse required for 120 or 277VAC units

Two fuses needed for 208,240 or 480VAC units

Instant re-strike ballast – enables a hot HPS

lamp to immediately re-strike after a momentary
loss of arc due to voltage fluctuation or power
outage. It has no effect on the warm-up period of
cold lamps (Max 150W HPS only).

Dome reflector or 30

°

angle reflector.

Protect Guard.

High power factor – Minimum P. F. 90%.

Technical Data

Voltage Range - AC 100V~480V

Watts Range - 30~400W

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Certification

Certified by KOGAS

(Korea Gas Safety Corporation)

Weight

28 kg 

Compliances

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof

enclosures “d”

ANSI /ASME B (1.20.1 Pipe threads, General

purpose(Inch)

ISO 228/1 Pipe threads where pressure-tight

joints are not made on the threads

ISO 261 Metric screw thread

Lighting Fixtures

A

catalog_eng-html.html
background image

Model Number Logic

ex) Metal Halide High power factor type Stanchion Mounting, AC220V, 250W, Guard required MLES 25 22 ST G P

Lamp Type

C-Fluorescent
S-HPS(High
pressure sodium)
M-Metal
V-Mercury

0

Series 
Constant 

LES

Lamp Wattage

03- 30W-C
08- 85W-C
10-100W-S
15-150W-S
17-175W-M
25-250W-M.S.V
40-400W-M.S.V

00

Voltage

@

60Hz

12-AC120V
20-AC208V
22-AC220V
24-AC-240V
27-AC277V
48-AC480V 

00

Mounting Type

PT-Pendant
CL-Ceiling
ST-Stanchion
4B-40

°

Bracket

9B-90

°

Bracket

00

0

G-Omit G if guard

is not required

0

P-Omit P if High
powerfactor 
is not required

Lighting Fixtures

A18 _ A19

Lighting Fixtures

A

Dimensions

Ceiling Type

Pendant Type

Standard Type Reflector

40° Bracket Type

90° Bracket Type

30° Dome Type Reflector

Dimensions (mm) 

catalog_eng-html.html
background image

0

1

2

3

4

5

6

7

8

9

10

.63 .63 .63 .61 .61 .61 .59 .59 .59 .56 .56 .56 .54 .54 .54 .53

.54 .52 .50 .53 .51 .49 .51 .49 .47 .49 .47 .46 .47 .46 .44 .43

.47 .43 .40 .46 .42 .39 .44 .41 .38 .42 .40 .38 .41 .39 .37 .35

.41 .36 .33 .40 .36 .32 .38 .35 .32 .37 .34 .31 .36 .33 .31 .30

.36 .31 .28 .35 .31 .27 .34 .30 .27 .33 .29 .27 .32 .29 .26 .25

.32 .27 .24 .32 .27 .24 .30 .26 .23 .29 .26 .23 .28 .25 .23 .22

.29 .24 .21 .29 .24 .21 .28 .23 .20 .27 .23 .20 .26 .23 .20 .19

.26 .22 .18 .26 .21 .18 .25 .21 .18 .24 .21 .18 .24 .20 .18 .17

.24 .20 .16 .24 .19 .16 .23 .19 .16 .22 .19 .16 .22 .18 .16 .15

.22 .18 .15 .22 .18 .15 .21 .17 .15 .21 .17 .15 .20 .17 .15 .14

.21 .16 .14 .20 .16 .14 .20 .16 .13 .19 .16 .13 .19 .16 .13 .12

.89 .89 .89 .87 .87 .87 .83 .83 .83 .79 .79 .79 .76 .76 .76  .74

.77 .74 .71 .76 .73 .70 .72 .70 .68 .70 .68 .66 .67 .65 .64  .62

.67 .62 .58 .66 .61 .57 .63 .59 .56 .61 .57 .54 .58 .56 .53  .52

.59 .53 .48 .58 .52 .47 .55 .50 .46 .53 .49 .46 .51 .48 .45  .43

.52 .45 .40 .51 .45 .40 .49 .44 .39 .47 .42 .39 .46 .41 .38  .36

.46 .39 .34 .45 .39 .34 .44 .38 .34 .42 .37 .33 .41 .36 .33  .31

.41 .35 .30 .41 .34 .30 .39 .34 .29 .38 .33 .29 .37 .32 .29  .27

.38 .31 .26 .37 .31 .26 .36 .30 .26 .35 .30 .26 .34 .29 .26  .24

.34 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23  .21

.31 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21  .19

.29 .23 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .27 .22 .19  .17

.89 .89 .89 .87 .87 .87 .83 .83 .83 .79 .79 .79 .76 .76 .76  .74

.77 .74 .71 .76 .73 .70 .72 .70 .68 .70 .68 .66 .67 .65 .64  .62

.67 .62 .58 .66 .61 .57 .63 .59 .56 .61 .57 .54 .58 .56 .53  .52

.59 .53 .48 .58 .52 .47 .55 .50 .46 .53 .49 .46 .51 .48 .45  .43

.52 .45 .40 .51 .45 .40 .49 .44 .39 .47 .42 .39 .46 .41 .38  .36

.46 .39 .34 .45 .39 .34 .44 .38 .34 .42 .37 .33 .41 .36 .33  .31

.41 .35 .30 .41 .34 .30 .39 .34 .29 .38 .33 .29 .37 .32 .29  .27

.38 .31 .26 .37 .31 .26 .36 .30 .26 .35 .30 .26 .34 .29 .26  .24

.34 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23  .21

.31 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21  .19

.29 .23 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .27 .22 .19  .17

80

70

50

30

10

0

50 30 10

20% Effective Floor Cavity Reflectance

50 30 10 50 30 10 50 30 10 50 30 10

0

% Effective

Ceiling Cavity

Reflectance 1cc

% Wall 

Reflectance 1w

Room Cavity

Ratio RCR

LES Series - Ex d II B IP54  

Lighting Fixture

Ex d II B IP54

IEC 60079-0, 1

IEC 60529 

Photometric Data

Fluorescent 30W

ZONAL CAVITY METHOD

0

5

15

25

35

45

55

65

101

101

85

112

101

99

96

88

75

85

90

95

105

115

125

135

73

47

39

-

-

-

-

-

cd/1000 lm

Angle

cd/1000 lm

Angle

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

50 30 10

20% Effective Floor Cavity Reflectance

50 30 10 50 30 10 50 30 10 50 30 10

0

% Effective

Ceiling Cavity

Reflectance 1cc

% Wall 

Reflectance 1w

Room Cavity

Ratio RCR

Metal Halide 250W

ZONAL CAVITY METHOD

0

5

15

25

35

45

55

65

122

108

105

170

133

133

171

126

75

85

90

95

105

115

125

135

112

38

17

-

-

-

-

-

cd/1000 lm

Angle

cd/1000 lm

Angle

0

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

50 30 10

20% Effective Floor Cavity Reflectance

50 30 10 50 30 10 50 30 10 50 30 10

0

% Effective

Ceiling Cavity

Reflectance 1cc

% Wall 

Reflectance 1w

Room Cavity

Ratio RCR

High Pressure Sodium 250W

ZONAL CAVITY METHOD

0

5

15

25

35

45

55

65

172

135

105

182

108

101

125

125

75

85

90

95

105

115

125

135

88

51

30

-

-

-

-

-

cd/1000 lm

Angle

cd/1000 lm

Angle

Lighting Fixtures

A

catalog_eng-html.html
background image

SEU Series - Ex d II C IP66  

Lighting Fixture

Ex d II C IP66

IEC 60079-0, 1

IEC 60529 

Applications

SEU Series Lighting Fixtures are designed for installations where moisture, dirt, dust, corrosion 

and vibration may be present, or IEC 60529 IP66 areas where wind, water, snow or high ambient 
can be expected.

They can be used in locations made hazardous due to the presence of flammable or explosive 

gases, vapors and combustible dusts as defined by the IEC 60079-0,1.

Applications include classified areas such as paint manufacturing plants, ammunition facilities, 

oil and gas producing and refining plants, off-shore and dockside installations, tank farms, 
pipeline pumping stations and marine loading and fuel transfer terminals.

Hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired.

Features

Fixture is factory wired; power is fed through “wireless”connection block which serves as a mechanical

seal between conduit and mogul compartments, eliminating the need for a field installed seal. The result

is fast, easy installation.

Wide range of light sources and wattages to meet specific lighting needs – 20W Fluorescent;100, 200 and

300W incandescent.

Two light sources – Compact fluorescent, Incandescent.

Mounting choice – Pendant,Ceiling,25

°

Stanchion, 40

°

or 90

°

wall mount, all with “wireless ” design that

allows fast, easy fixture installation.

Corrosion resistant – Copper-free aluminum die-cast construction. Baked powder epoxy finish, electro

statically applied. Exposed hardware is stainless steel.

Pendant type is standard.

Standard Materials

Copper-free Aluminium (Cast Aluminium Alloy)

Globe : Heat Resistant Glass

Reflector : High Purity Aluminium 

Guard & Accessory : Stainless Steel

Options

Dome reflector or 30

°

angle reflector.

Protect Guard.

Technical Data

Voltage Range - AC 120V~240V

Watts Range - 20~300W

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Certification

Certified by KOSHA

(Korea Occupational Safety & Health Agency)

Weight

10 kg 

Compliances

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof

enclosures “d”

ANSI /ASME B1.20.1 Pipe threads, General

purpose(Inch)

ISO 228/1 Pipe threads where pressure-tight

joints are not made on the threads

ISO 261 Metric screw thread

Lighting Fixtures

A20 _ A21

Lighting Fixtures

A

catalog_eng-html.html
background image

SEU Series - Ex d II C IP66  

Lighting Fixture

Ex d II C IP66

IEC 60079-0, 1

IEC 60529 

Model Number Logic

Lamp Type

C- Fluorescent
I - Incandescent

0

Series 
Constant 

SEU

Lamp Wattage

02- 20W - C
10 -100W- I
20-200W - I
30-300W - I

00

Voltage

@

50/60Hz

12- AC120V
22 - AC220V
24 - AC240V

00

Mounting Type

PT-Pendant
CL-Ceiling
ST-Stanchion
4B-40

°

Bracket

9B-90

°

Bracket

00

0

ex) Incandescent type Stachion Mounting, AC220V, 200W, Guard required ISEU 20 22 ST G

G-Omit G if guard

is not required

Lighting Fixtures

A

Dimensions

Pendant Type

Ceiling Type

Standard Type Reflector

30° Dome Type Reflector

90° Bracket Type 

Stanchion Type

40° Bracket Type

Dimensions (mm) 

catalog_eng-html.html
background image

0

1

2

3

4

5

6

7

8

9

10

.69 .69 .69 .67 .67 .67 .64 .64 .64 .62 .62 .62 .59 .59 .59 .58

.58 .55 .52 .57 .54 .51 .54 .52 .50 .52 .50 .48 .50 .48 .47 .45

.48 .44 .39 .47 .43 .39 .45 .41 .38 .43 .40 .37 .41 .39 .36 .35

.41 .35 .31 .40 .35 .31 .38 .34 .30 .37 .33 .29 .35 .32 .29 .27

.36 .30 .25 .35 .29 .25 .33 .28 .25 .32 .28 .24 .30 .27 .24 .22

.31 .25 .21 .31 .25 .21 .29 .24 .21 .28 .24 .20 .27 .23 .20 .19

.28 .22 .18 .27 .22 .18 .26 .21 .18 .25 .21 .17 .24 .20 .17 .16

.25 .20 .16 .25 .19 .15 .24 .19 .15 .23 .18 .15 .22 .18 .15 .14

.23 .17 .14 .22 .17 .14 .22 .17 .14 .21 .17 .13 .20 .16 .13 .12

.21 .16 .12 .21 .16 .12 .20 .15 .12 .19 .15 .12 .19 .15 .12 .11

.19 .14 .11 .19 .14 .11 .18 .14 .11 .18 .14 .11 .17 .14 .11 .10

.56 .52 .48 .53 .49 .46 .47 .44 .41 .41 .39 .37 .37 .35 .33  .30

.47 .41 .36 .44 .39 .34 .39 .34 .30 .34 .30 .28 .30 .27 .24  .22

.40 .33 .28 .37 .31 .27 .33 .28 .24 .29 .25 .21 .25 .22 .19  .17

.34 .28 .23 .32 .27 .22 .29 .24 .20 .25 .21 .18 .22 .18 .16  .13

.30 .24 .19 .28 .22 .18 .25 .20 .16 .22 .18 .14 .19 .16 .13  .10

.27 .20 .16 .25 .19 .15 .22 .17 .13 .19 .15 .12 .17 .13 .10  .09

.24 .17 .13 .22 .17 .13 .20 .15 .11 .17 .13 .10 .15 .11 .09  .07

.21 .15 .11 .20 .15 .11 .18 .13 .10 .16 .11 .09 .13 .10 .08  .06

.19 .14 .10 .18 .13 .09 .16 .12 .08 .14 .10 .07 .12 .09 .07  .05

.17 .12 .08 .16 .11 .08 .15 .10 .07 .13 .09 .06 .11 .08 .06  .04

80

70

50

30

10

0

50 30 10

20% Effective Floor Cavity Reflectance

50 30 10 50 30 10 50 30 10 50 30 10

0

% Effective

Ceiling Cavity

Reflectance 1cc

% Wall 

Reflectance 1w

Room Cavity

Ratio RCR

Photometric Data

Fluorescent 20W

ZONAL CAVITY METHOD

0

5

15

25

35

45

55

65

63

63

65

79

78

80

92

101

75

85

90

95

105

115

125

135

108

100

93

-

-

-

-

-

cd/1000 lm

Angle

cd/1000 lm

Angle

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

50 30 10

20% Effective Floor Cavity Reflectance

50 30 10 50 30 10 50 30 10 50 30 10

0

% Effective

Ceiling Cavity

Reflectance 1cc

% Wall 

Reflectance 1w

Room Cavity

Ratio RCR

Incandescent 300W

ZONAL CAVITY METHOD

.60 .58 .56 .58 .57 .55 .56 .54 .53 .53 .52 .51 .51 .50 .49  .48

.53 .50 .47 .52 .49 .46 .50 .47 .45 .48 .46 .44 .46 .44 .43  .41

.47 .43 .40 .46 .42 .40 .44 .41 .39 .43 .40 .38 .41 .39 .37  .36

.42 .38 .34 .42 .37 .34 .40 .36 .33 .38 .35 .33 .37 .34 .32  .31

.38 .33 .30 .37 .33 .29 .36 .32 .29 .34 .31 .28 .33 .30 .28  .27

.38 .29 .25 .33 .29 .25 .32 .28 .25 .31 .27 .25 .30 .27 .24  .23

.30 .25 .22 .29 .25 .22 .28 .24 .21 .28 .24 .21 .27 .23 .21  .20

.27 .22 .19 .27 .22 .19 .26 .21 .19 .25 .21 .19 .24 .21 .18  .17

.24 .20 .17 .24 .20 .17 .23 .19 .16 .23 .19 .16 .22 .19 .16  .15

.22 .18 .15 .22 .17 .14 .21 .17 .14 .21 .17 .14 .20 .16 .14  .13

1

2

3

4

5

6

7

8

9

10

80

70

50

30

10

0

50 30 10

20% Effective Floor Cavity Reflectance

50 30 10 50 30 10 50 30 10 50 30 10

0

% Effective

Ceiling Cavity

Reflectance 1cc

% Wall 

Reflectance 1w

Room Cavity

Ratio RCR

ZONAL CAVITY METHOD

0

5

15

25

35

45

55

65

41

41

51

66

67

68

74

83

75

85

90

95

105

115

125

135

87

82

79

77

59

22

4

1

cd/1000 lm

Angle

cd/1000 lm

Angle

Incandescent 300W (Reflector : Standard type)

0

5

15

25

35

45

55

65

161

161

172

177

157

138

121

50

75

85

90

95

105

115

125

135

22

7

3

6

5

1

-

-

cd/1000 lm

Angle

cd/1000 lm

Angle

Lighting Fixtures

A22 _ A23

Lighting Fixtures

A

catalog_eng-html.html
background image

Incandescent 300W (Reflector : Angle 30

°

type) 

5

15

25

35

45

55

65

75

85

90

95

105

115

125

135

5

15

25

35

45

55

65

75

85

90

95

105

115

125

135

161

161

172

177

157

138

121

50.3

22

7

3

6

5

1

0

0

140

154

199

225

193

190

193

177

163

106

57

35

15

4

0

0

Angle

cd/1000 lm

FRONT 

Angle

cd/1000 lm

SIDE

SEU Series - Ex d II C IP66  

Lighting Fixture

Ex d II C IP66

IEC 60079-0, 1

IEC 60529 

Photometric Data

Lighting Fixtures

A

catalog_eng-html.html
background image

SES Series - Ex d II B IP54  

Lighting Fixture

Ex d II B IP54

IEC 60079-0, 1

IEC 60529 

Applications

SES Series Lighting Fixtures are designed for installations where moisture, dirt, dust, corrosion 

and vibration may be present, or IEC 60529 IP54 areas where wind, water, snow or high ambient 
can be expected.

They can be used in locations made hazardous due to the presence of flammable or explosive 

gases, vapors and combustible dusts as defined by the IEC 60079-0,1.

Applications include classified areas such as paint manufacturing plants, ammunition facilities, 

oil and gas producing and refining plants, off-shore and dockside installations, tank farms, pipeline 
pumping stations and marine loading and fuel transfer terminals. 

Hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired. 

Features

Wide range of light sources and wattages to meet specific lighting needs – 20W Fluorescent; 100, 200 and

300W incandescent. 

Two light sources – Compact fluorescent, Incandescent.

Mounting choice – Pendant, Ceiling, 40

°

or 90

°

wall mount.

Corrosion resistant – Copper-free aluminum die-cast construction. Baked powder epoxy finish, 

electro-statically applied. Exposed hardware is stainless steel. 

Pendant type is standard. 

Standard Materials

Copper-free Aluminium (Cast Aluminium Alloy)

Globe : Heat Resistant Glass

Reflector : High Purity Aluminium 

Guard & Accessory : Stainless Steel

Options

Dome reflector or 30

°

angle reflector.

Protect Guard. 

Compliances

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof 
enclosures “d” 

ANSI /ASME B 1.20.1 Pipe threads, General 

purpose(Inch)

ISO 228/1 Pipe threads where pressure-tight 
joints are not made on the threads

ISO 261 Metric screw thread

Technical Data

Voltage Range - AC 120V~240V

Watts Range - 20~300W 

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Certification

Certified by KOGAS

(Korea Gas Safety Corporation)

Weight

10 kg 

Lighting Fixtures

A

Lighting Fixtures

A24 _ A25

catalog_eng-html.html
background image

Model Number Logic

Lamp Type

C - Fluorescent
I - Incandescent 

0

Series 
Constant 

SES

Lamp Wattage

02 - 20W - C 
10 -100W- I
20-200W - I
30-300W - I

00

Voltage

@

50/60Hz

12 - AC120V
22 - AC220V
24 - AC240V 

00

Mounting Type

PT-Pendant 
CL-Ceiling
4B-40

°

Bracket

9B-90

°

Bracket

00

0

ex) Incandescent type Pendant, AC220V, 200W, Guard required ISES 20 22 PT G 

G-Omit G if guard
is not required

SES Series - Ex d II B IP54  

Lighting Fixture

Ex d II B IP54

IEC 60079-0, 1

IEC 60529 

Lighting Fixtures

A

Dimensions

Pendant Type

Ceiling Type

Standard Type Reflector

90° Bracket Type

40° Bracket Type

30° Dome Type Reflector

Dimensions (mm) 

catalog_eng-html.html
background image

0

1

2

3

4

5

6

7

8

9

10

.67.67.67

.56  .54  .51

.47  .43  .39

.40  .35  .30

.35  .29  .24

.30  .25  .20

.27  .21  .17 

.24  .19  .15

.22  .17  .13 

.20  .15  .12 

.18  .14  .10 

.66  .66  .66 

.55  .52  .50  

.46  .42  .38 

.39  .34  .30

.34  .29  .24

.30  .24  .20

.27  .21  .17

.24  .19  .15 

.22  .17  .13 

.20  .15  .12 

.18  .13  .10 

.63  .63  .63

.53  .50  .48

.44  .40  .37 

.37  .33  .29

.32  .28  .24

.29  .24  .20 

.25  .21  .17 

.23  .18  .15 

.21  .16  .13 

.19  .15  .11

.18  .13  .10

.60  .60  .60

.50  .49  .47

.42  .39  .36 

.36  .32  .29 

.31  .27  .24 

.27  .23  .20

.24  .20  .17

.22  .18  .15 

.20  .16  .13 

.18  .14  .13 

.17.13  .10

.57 .57 .57

.48  .47  .45 

.40  .38  .35 

.34  .31  .28 

.30  .26  .23 

.26  .22  .19 

.23  .20  .17 

.21  .17  .14 

.19  .16  .13 

.18  .14  .11 

.16  .13  .10 

.56

.44

.34

.27

.22

.18

.15

.13

.12

.10

.09

80

70

50

30

10

0

50 30 10

20% Effective Floor Cavity Reflectance

50 30 10 50 30 10 50 30 10 50 30 10

0

%Effective

Ceiling Cavity

Reflectance 1cc

%Wall 

Reflectance 1w

Room Cavity

Ratio RCR

Photometric Data

Fluorescent 20W

ZONAL CAVITY METHOD

0

5

15

25

35

45

55

65

48

49

51

62

78

89

98

101

75

85

90

95

105

115

125

135

101

94

91

-

-

-

-

-

cd/1000 lm

Angle

cd/1000 lm

Angle

0

1

2

3

4

5

6

7

8

9

10

.87.87.87

.76  .73  .70

.67  .62  .57

.59  .53  .48

.52  .46  .41

.46  .40  .35 

.42  .35  .31 

.38  .32  .27 

.35  .29  .25

.32  .28  .22 

.30  .24  .20

.85  .85  .85

.74  .71  .69 

.65  .61  .57 

.57  .52  .47 

.51  .45  .40 

.44  .39  .35 

.40  .34  .30 

.36  .31  .27 

.33  .28  .24 

.31  .26  .22

.29  .24  .20

.81  .81  .81

.71  .69  .67

.63  .59  .55 

.55  .50  .47 

.49  .44  .40 

.44  .39  .35   

.40  .34  .30 

.36  .31  .27 

.33  .28  .24 

.31  .26  .22

.29  .24  .20

.78  .78  .78

.68  .66  .65

.60  .57  .54 

.53  .49  .45 

.47  .43  .39 

.43  .38  .34   

.39  .34  .30 

.35  .30  .27 

.33  .28  .24 

.30  .25  .22

.28  .23  .20

.75  .75  .75

.66  .64  .63

.58  .55  .53 

.51  .48  .45 

.46  .42  .39 

.41  .37  .37   

.38  .33  .30 

.34  .30  .07 

.32  .27  .24 

.29  .25  .22

.27  .23  .20

.73

.61

.51

.43

.37

.32

.28

.25

.23

.21

.19

80

70

50

30

10

0

50 30 10

20% Effective Floor Cavity Reflectance

50 30 10 50 30 10 50 30 10 50 30 10

0

%Effective

Ceiling Cavity

Reflectance 1cc

%Wall 

Reflectance 1w

Room Cavity

Ratio RCR

Incandesvent 100W

ZONAL CAVITY METHOD

0

5

15

25

35

45

55

65

167

180

140

146

171

153

132

119

75

85

90

95

105

115

125

135

107

28

10

-

-

-

-

-

cd/1000 lm

Angle

cd/1000 lm

Angle

Lighting Fixtures

A26 _ A27

Lighting Fixtures

A

catalog_eng-html.html
background image

FLES Series - Ex d II B IP65  

Fluorescent Lighting

Ex d II B IP65 

IEC 60079-0, 1

IEC 60529 

Applications

FLES Series Lighting Fixtures are designed for installations where moisture, dirt, dust, corrosion 

and vibration may be present, or IEC 60529 IP65 areas where wind, water, snow or high ambient 
can be expected.

They can be used in locations made hazardous due to the presence of flammable or explosive 

gases, vapors and combustible dusts as defined by the IEC 60079-0,1.

Applications include classified areas such as paint manufacturing plants, ammunition facilities, 

oil and gas producing and refining plants, off-shore and dockside installations, tank farms, pipeline 
pumping stations and marine loading and fuel transfer terminals. 

Hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired. 

Features

Factory sealed unit – no external seals required. Installation is easy and fast.

Available in 40~20watt instant and rapid start fixtures for operation on AC220V or AC110V. 

Two close-up plugs furnished for each end of fixture. 

Explosion-proof, impact- and heat resistant (HDT 155

) poly carbonate tubes protect lamps. 

Reflectors can easily be removed for replacement or cleaning, using only a screwdriver.

Electro-statically applied epoxy polyester finish is baked on for high density corrosion protection. 

Standard Materials

Copper-free Aluminium (Cast Aluminium Alloy)

Globe : Poly Carbonate Tube

Reflector : Steel

Guard & Accessory : Stainless Steel

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Options

Protect Guard. 

Emergency Battery - 20min ~1hour

Technical Data

Voltage Range - AC110V~240V

Watts Range - Below 40W

Certification

Certified by KOSHA 

(Korea Occupational Safety & Health Agency)

Weight

12 kg 

Compliances

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof 
enclosures “d” 

ANSI /ASME B 1.20.1 Pipe threads, General 

purpose(Inch)

ISO 228/1 Pipe threads where pressure-tight 
joints are not made on the threads

ISO 261 Metric screw thread

Lighting Fixtures

A

catalog_eng-html.html
background image

0

1

2

3

4

5

6

7

8

9

10

.78.78 .78 .78

.71 .68 .66 .63

.65 .60 .56 .52

.60.53 .48 .43

.54 .47 .41 .37

.50.41 .35 .31

.45.37 .31 .26 

.42.33 .27 .23

.38 .29 .24 .20

.35.26 .21 .17

.33.24 .19 .15

.76.76 .76 .76

.70 .67 .64 .62

.63 .56 .55 .51

.58.52 .47 .43

.53 .46 .41 .36

.48.40 .35 .31

.44 .36 .30 .26 

.41.32 .27 .23

.37 .29 .33 .20

.34 .26 .21 .21

.32.24 .18 .15

.73  .73  .73 

.64  .62  .60  

.56  .53  .50 

.50  .46  .42

.44  .40  .36

.39  .34  .30

.35  .30  .26

.31  .26  .23 

.28  .23  .20 

.15  .25  .20 

.23  .18  .15 

.70  .70  .70

.62  .60  .58 

.54  .51  .49 

.48  .45  .42

.43  .39  .35

.38  .33  .30

.34  .29  .26

.30  .26  .22 

.27  .23  .19 

.17  .24  .20 

.22  .18  .15 

.67  .67  .67 

.59  .58  .57  

.52  .50  .48 

.46  .43  .41

.41  .38  .35

.36  .33  .30

.33  .29  .26

.29  .25  .22 

.26  .22  .19 

.17  .24  .20 

.22  .18  .15 

80

70

50

30

10

0

70 50 30 10

20% Effective Floor Cavity Reflectance

70 50 30 10 50 30 10 50 30 10 50 30 10

0

%Effective

Ceiling Cavity

Reflectance 1cc

%Wall 

Reflectance 1w

Room Cavity

Ratio RCR

Photometric Data

ZONAL CAVITY METHOD

0

5

10
15
20
25
30
35
40

50

55
60
65
70
75
80
85
90

414

425
410
409
403
374
358
324
300

414

427
414
417
417
393
386
363
352

Horizontal angle

0

90

0

90

Candle power 40W Rapid start (cd/1000lm)

Vertical

angle 

Horizontal angle

Vertical

angle 

230

198
162
129

82
54
25

8
2

307

293
261
218
152
107

70
26

7

Dimension 

Dimensions (mm) 

Model Number Logic

Series 
Constant 

FLES

Lamp Wattage

02- 20W
03- 32W
04- 40W

00

Voltage

@

60Hz

11-AC110V
12-AC120V
20-AC208V
22-AC220V  
24-AC-240V 

00

Mounting Type

PT-Pendant 
CL-Ceiling 

00

0

ex) Ceiling, AC110V, 40W, Guard required FLES 04 11 CL G 

G-Omit G if guard
is not required

.65

.55

.46

.39

.34

.28

.24

.21

.18

.17

.14

Lighting Fixtures

A28 _ A29

Lighting Fixtures

A

catalog_eng-html.html
background image

FLNS Series - Ex nR II IP65  

Fluorescent Lighting

Ex nR II IP66

IEC 60079-0, 15

IEC 60529

Applications

FLNS Series Lighting Fixtures are designed for installations where moisture, dirt, dust, corrosion 

and vibration may be present, or IEC 60529  IP66 areas where wind, water, snow or high ambient 
can be expected.

They can be used in locations made hazardous due to the presence of flammable or explosive 

gases, vapors and combustible dusts as defined by the IEC 60079-0,15. 

Applications include classified areas such as paint manufacturing plants, ammunition facilities, 

oil and gas producing and refining plants, off-shore and dockside installations, tank farms, pipeline 
pumping stations and marine loading and fuel transfer terminals. 

Hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired. 

Features

Installation is easy and fast. 

Available in 40~20 watt instant and rapid start fixtures for operation on AC220V or AC110V. 

Impact- and heat resistant (HDT 155

) poly carbonate tubes protect lamps. 

Reflectors can easily be removed for replacement or cleaning, using only a screwdriver. 

Electro-statically applied epoxy polyester finish is baked on for high density corrosion protection. 

Mounting choice – Pendant, Ceiling. 

Integral ballasts – separate ballasts are not required. Lowest installed cost. 

Pendant type is standard.  

Standard Materials

Seamless Steel Sheet 

Globe : Poly Carbonate 

Reflector : Steel 

Guard & Accessory : Stainless Steel

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Options

Protect Guard.

Emergency Battery – 20 min~1 hour

Technical Data

Voltage Range - AC 110V~240V

Watts Range - Below  40W

Certification

Certified by KOSHA 

(Korea Occupational Safety & Health Agency)

Weight

11.5 kg 

Compliances

IEC 60079-0 Equipment – General requirements

IEC 60079-15 Construction, test and marking of 

type of protection “n” electrical apparatus 

ANSI /ASME B1.20.1 Pipe threads, General 

purpose (Inch)

ISO 228/1Pipe threads where pressure-tight 
joints are not made on the threads

ISO 261 Metric screw thread

Lighting Fixtures

A

catalog_eng-html.html
background image

.65

.55

.46

.39

.34

.28

.24

.21

.18

.17

.14

0

1

2

3

4

5

6

7

8

9

10

.78.78 .78 .78

.71 .68 .66 .63

.65 .60 .56 .52

.60.53 .48 .43

.54 .47 .41 .37

.50.41 .35 .31

.45.37 .31 .26 

.42.33 .27 .23

.38 .29 .24 .20

.35.26 .21 .17

.33.24 .19 .15

.76.76 .76 .76

.70 .67 .64 .62

.63 .56 .55 .51

.58.52 .47 .43

.53 .46 .41 .36

.48.40 .35 .31

.44 .36 .30 .26 

.41.32 .27 .23

.37 .29 .33 .20

.34 .26 .21 .21

.32.24 .18 .15

.73  .73  .73 

.64  .62  .60  

.56  .53  .50 

.50  .46  .42

.44  .40  .36

.39  .34  .30

.35  .30  .26

.31  .26  .23 

.28  .23  .20 

.15  .25  .20 

.23  .18  .15 

.70  .70  .70

.62  .60  .58 

.54  .51  .49 

.48  .45  .42

.43  .39  .35

.38  .33  .30

.34  .29  .26

.30  .26  .22 

.27  .23  .19 

.17  .24  .20 

.22  .18  .15 

.67  .67  .67 

.59  .58  .57  

.52  .50  .48 

.46  .43  .41

.41  .38  .35

.36  .33  .30

.33  .29  .26

.29  .25  .22 

.26  .22  .19 

.17  .24  .20 

.22  .18  .15 

80

70

50

30

10

0

70 50 30 10

20% Effective Floor Cavity Reflectance

70 50 30 10 50 30 10 50 30 10 50 30 10

0

%Effective

Ceiling Cavity

Reflectance 1cc

%Wall 

Reflectance 1w

Room Cavity

Ratio RCR

Photometric Data

ZONAL CAVITY METHOD

0

5

10
15
20
25
30
35
40

50

55
60
65
70
75
80
85
90

414

425
410
409
403
374
358
324
300

414

427
414
417
417
393
386
363
352

Horizontal angle

0

90

0

90

Candle power 40W Rapid start (cd/1000lm)

Vertical

angle 

Horizontal angle

Vertical

angle 

230

198
162
129

82
54
25

8
2

307

293
261
218
152
107

70
26

7

Dimensions 

Model Number Logic

Series 
Constant

FLNS

Lamp Wattage

02- 20W
03- 32W
04- 40W

00

Voltage

@

60Hz

11-AC110V
12-AC120V
20-AC208V
22-AC220V  
24-AC240V 

00

Mounting Type

PT-Pendant 
CL-Ceiling

00

0

ex) AC220V ,20W, Pendant FLNS 02 22 PT

G-Omit G if guard
is not required

Dimensions (mm) 

Lighting Fixtures

A30 _ A31

Lighting Fixtures

A

catalog_eng-html.html
background image

FLXS Series - For Non Hazard. IP66  

Fluorescent Lighting

Non hazadous  

area IP66

IEC 60529

Applications

FLXS Series Lighting Fixtures are designed for installations where moisture, dirt, dust, corrosion 

and vibration may be present, or IEC 60529  IP66 areas where wind, water, snow or high ambient 
can be expected.

Both indoors and outdoors where long life and low maintenance costs are desired.

Features

Installation is easy and fast.

Available in 40~20 watt instant and rapid start fixtures for operation on AC220V or AC110V. 

Impact - and heat resistant glass plate protect lamps.

Electro-statically applied epoxy polyester finish is baked on for high density corrosion protection. 

Choice of mountings; Flush mounting or Surface mounting (pendant, feed thru for wall or 

ceiling mounting).  

Integral ballasts – separate ballasts are not required. Lowest installed cost. 

Standard Materials

Seamless Steel Sheet 

Globe : Heat Resistant Glass

Reflector : Tube Steel 

Guard & Accessory : Stainless Steel

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Options

Protect Guard.

Emergency Battery – 20 min ~1 hour

Technical Data

Voltage Range - AC 110V~240V

Watts Range - Below  40W

Weight

30 kg 

Compliances

IEC 60529 -Degrees of protection provided by 

enclosures 

ANSI /ASME B 1.20.1 Pipe threads, General 

purpose(Inch) 

ISO 228/1  Pipe threads where pressure-tight 

joints are not made on the threads 

ISO 261 Metric screw thread

Model Number Logic

Series 
Constant 

FL

VS -Vapor proof 
DS-Dust proof  

00

Voltage

@

60Hz

11-AC110V
12-AC120V
20-AC208V
22-AC220V  
24-AC-240V 

00

ex) Vapor proof 40W, AC220V FLVS 04 22 

Lamp Wattage

02- 20W
03- 32W
04- 40W

00

Lighting Fixtures

A

catalog_eng-html.html
background image

.65

.55

.46

.39

.34

.28

.24

.21

.18

.17

.14

0

1

2

3

4

5

6

7

8

9

10

.78.78 .78 .78

.71 .68 .66 .63

.65 .60 .56 .52

.60.53 .48 .43

.54 .47 .41 .37

.50.41 .35 .31

.45.37 .31 .26 

.42.33 .27 .23

.38 .29 .24 .20

.35.26 .21 .17

.33.24 .19 .15

.76.76 .76 .76

.70 .67 .64 .62

.63 .56 .55 .51

.58.52 .47 .43

.53 .46 .41 .36

.48.40 .35 .31

.44 .36 .30 .26 

.41.32 .27 .23

.37 .29 .33 .20

.34 .26 .21 .21

.32.24 .18 .15

.73  .73  .73 

.64  .62  .60  

.56  .53  .50 

.50  .46  .42

.44  .40  .36

.39  .34  .30

.35  .30  .26

.31  .26  .23 

.28  .23  .20 

.15  .25  .20 

.23  .18  .15 

.70  .70  .70

.62  .60  .58 

.54  .51  .49 

.48  .45  .42

.43  .39  .35

.38  .33  .30

.34  .29  .26

.30  .26  .22 

.27  .23  .19 

.17  .24  .20 

.22  .18  .15 

.67  .67  .67 

.59  .58  .57  

.52  .50  .48 

.46  .43  .41

.41  .38  .35

.36  .33  .30

.33  .29  .26

.29  .25  .22 

.26  .22  .19 

.17  .24  .20 

.22  .18  .15 

80

70

50

30

10

0

70 50 30 10

20% Effective Floor Cavity Reflectance

70 50 30 10 50 30 10 50 30 10 50 30 10

0

%Effective

Ceiling Cavity

Reflectance 1cc

%Wall 

Reflectance 1w

Room Cavity

Ratio RCR

Photometric Data

ZONAL CAVITY METHOD

0
5

15
25
35
45
55
65
75
85
90

222
221
213
199
177
149
110

70
14

2
0

222
223
221
210
199
177
152

97
46

2
0

Horizontal angle

0

90

Candle power 40W Rapid start (cd/1000lm)

Vertical

angle 

Dimensions 

Dimensions (mm) 

Lighting Fixtures

A32 _ A33

Lighting Fixtures

A

catalog_eng-html.html
background image

LXS Series - For Non Hazard. Dust & Vapor Proof IP65  

Lighting Fixture

Dust & Vapor 
Proof IP65 

IEC 60529

Applications

LXS Series Lighting Fixtures are designed for installations where moisture, dirt, dust, corrosion 

and vibration may be present, or IEC 60529  IP65 areas where wind, water, snow or high ambient 
can be expected.

Applications include classified areas such as paint manufacturing plants, ammunition facilities, 

oil and gas producing and refining plants, off-shore and dockside installations, tank farms, pipeline 
pumping stations and marine loading and fuel transfer terminals. 

Non Hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired.

Features

Wide range of light sources and wattages to meet specific lighting needs 150, 200, 250 and 400W high

pressure sodium (HPS); 200, 250 and 400W mercury vapor (MV); 175, 250 and 400W metal halide (MH). 

Three light sources – Compact fluorescent, high pressure sodium, metal halide and mercury vapor. 

Mounting choice – Pendant, Ceiling, 40

°

or 90

°

wall mount. 

Corrosion resistant – Copper-free aluminum die-cast construction. Baked powder epoxy finish, 

electro-statically applied. Exposed hardware is stainless steel. 

Pendant type is standard.

Standard Materials

Seamless Steel Sheet 

Globe : Heat Resistant Glass

Reflector : High Purity Aluminium

Guard & Accessory : Stainless Steel

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Options

Fuse – to protect ballast and capacitors against 
abnormal line conditions. 

One fuse required for 120 or 277VAC units 

Two fuses needed for 208,240 or 480VAC units 

Instant re-strike ballast – enables a hot HPS 
lamp to immediately re-strike after a momentary
loss of arc due to voltage fluctuation or power outage.
It has no effect on the warm-up period of cold lamps
(Max 150W HPS only). 

Dome reflector or 30

°

angle reflector. 

High power factor – Minimum P. F. 90%

Technical Data

Voltage Range - AC 110V~240V

Watts Range - 150W~400W

Certification

Certified by KOSHA 

(Korea Occupational Safety & Health Agency)

Weight

19kg 

Compliances

IEC 60529 -Degrees of protection provided by 

enclosures 

ANSI /ASME B 1.20.1 Pipe threads, General 

purpose(Inch) 

ISO 228/1  Pipe threads where pressure-tight 

joints are not made on the threads 

ISO 261 Metric screw thread

Lighting Fixtures

A

catalog_eng-html.html
background image

Model Number Logic

Lamp Type

S-HPS (High 
pressure sodium)
M-Metal
V-Mercury

0

Series 
Constant 

LXS

VS
-Vapor proof 
DS
-Dust proof  

Lamp Wattage

15-150W-S
17-175W-M
20-200W-S.V
25-250W-M.S.V
40-400W-M.S.V 

00

Voltage

@

60Hz

11-AC110V
12-AC120V
20-AC208V  
22-AC220V
24-AC-240V

00

Mounting Type

PT-Pendant 
CL-Ceiling
4B-40

°

Bracket

9B-90

°

Bracket

00

0

ex) High Pressure Sodium, Vapor proof 90

°

Bracket Mounting, AC220V, 400W SLVS 40 22 9B

P-Omit P if High 
powerfactor is
not required 

Lighting Fixtures

A34 _ A35

Lighting Fixtures

A

Dimensions

Pendant Type

Ceiling Type

Standard Type Reflector

90° Bracket Type

40° Bracket Type

30° Dome Type Reflector

Dimensions (mm) 

catalog_eng-html.html
background image

0

1

2

3

4

5

6

7

8

9

10

.86  .86  .86    .84  .84  .84    .80  .80  .80    .77  .77  .77    .74  .74  .74 

.77  .75  .72   .76  .73  .71    .73  .71  .69    .70  .68  .67    .67  .66  .65 

.70  .66  .63   .69  .65  .62    .66  .63  .61    .64  .61  .59    .62  .60  .58  

.63  .58  .55   .62  .58  .54    .60  .56  .53    .58  .55  .52    .56  .54  .51 

.57  .52  .48   .56  .51  .48    .55  .50  .47    .53  .49  .46    .52  .48  .46 

.52  .46  .42   .51  .46  .42    .50  .45  .42    .48  .45  .41    .47  .44  .41 

.47  .42  .38   .47  .41  .38    .46  .41  .37    .44  .40  .37    .43  .40  .37

.43  .38  .34   .43  .38  .34    .42  .37  .34    .41  .37  .33    .40  .36  .33 

.40  .34  .31   .39  .34  .31    .38  .34  .30    .38  .33  .30    .37  .33  .30  

.37  .31  .28   .36  .31  .28    .36  .31  .28    .35  .31  .27    .34  .30  .27

.34  .29  .25   .34  .29  .25    .33  .28  .25    .32  .28  .25    .32  .28  .25 

.72 

.64 

.57

.50 

.45 

.40 

.35 

.32

.29

.26 

.24

80

70

50

30

10

0

50 30 10

20% Effective Floor Cavity Reflectance

50 30 10 50 30 10 50 30 10 50 30 10

0

%Effective

Ceiling Cavity

Reflectance 1cc

%Wall 

Reflectance 1w

Room Cavity

Ratio RCR

Photometric Data

Metal Halide 250W

ZONAL CAVITY METHOD

0
5

10
15
20
25
30
35
40
45

203
168
156
143
152
174
213
238
229
229

50
55
60
65
70
75
80
85
90

-

220
204
137

58
27
12

6
3
3

-

cd/1000 lm

Angle

cd/1000 lm

Angle

0

1

2

3

4

5

6

7

8

9

10

.59  .59  .59   .58  .58  .58    .55  .55  .55    .53  .53  .53    .51  .51  .51

.53  .52  .50   .52  .51  .49    .50  .49  .48 .   48  .47  .46    .46  .46  .45 

.48  .46  .43   .47  .45  .43    .46  .44  .42    .44  .42  .41    .43  .41  .40  

.44  .41  .38   .43  .40  .38    .42  .39  .37    .40  .38  .36    .39  .37  .36  

.40  .36  .34   .39  .36  .34    .38  .35  .33    .37  .35  .33    .36  .34  .32  

.37  .33  .30   .36  .33  .30    .35  .32  .30    .34  .32  .29    .33  .31  .29

.34  .30  .27   .33  .30  .27    .32  .29  .27    .32  .29  .27    .31  .28  .27 

.31  .27  .25   .31  .27  .25    .30  .27  .25    .29  .26  .24    .29  .26  .24

.29  .25  .23    .28  .25  .23    .28  .25  .22    .27  .24  .22    .27  .24  .22 

.27  .23  .21    .26  .23  .21    .26  .23  .21    .25  .23  .21    .25  .22  .21  

.25  .22  .19    .25  .21  .19    .24  .21  .19    .24  .21  .19    .23  .21  .19 

.50  

.44  

.39

.35 

.31 

.28  

.26 

.23 

.21

.20 

.18 

80

70

50

30

10

0

50 30 10

20% Effective Floor Cavity Reflectance

50 30 10 50 30 10 50 30 10 50 30 10

0

%Effective

Ceiling Cavity

Reflectance 1cc

%Wall 

Reflectance 1w

Room Cavity

Ratio RCR

Metal Halide 250W

ZONAL CAVITY METHOD

0
5

10
15
20
25
30
35
40
45

170
118
128
152
175
170
158
148
145
142

50
55
60
65
70
75
80
85
90

-

130
102

80
50
25
13

8
5
3

-

cd/1000 lm

Angle

cd/1000 lm

Angle

LXS Series - For Non Hazard. Dust & Vapor Proof IP65  

Lighting Fixture

Dust & Vapor 
Proof IP65 

IEC 60529

Lighting Fixtures

A

catalog_eng-html.html
background image

SXS Series - For Non Hazard. Dust & Vapor Proof IP65  

Lighting Fixture

Dust & Vapor 
Proof IP65

IEC 60529

Applications

SXS Series Lighting Fixtures are designed for installations where moisture, dirt, dust, corrosion 

and vibration may be present, or IEC 60529  IP65 areas where wind, water, snow or high ambient 
can be expected.

Applications include classified areas such as paint manufacturing plants, ammunition facilities, 

oil and gas producing and refining plants, off-shore and dockside installations, tank farms, pipeline 
pumping stations and marine loading and fuel transfer terminals. 

Non Hazardous areas, both indoors and outdoors where long life and low maintenance 

costs are desired.  

Features

Mounting choice – Pendant, Ceiling, 40

°

or 90

°

wall mount.

Corrosion resistant – Copper-free aluminum die-cast construction. Baked powder epoxy finish,

electro-statically applied. Exposed hardware is stainless steel. 

Pendant type is standard. 

Standard Materials

Seamless Steel Sheet

Globe : Heat Resistant Glass

Reflector : High Purity Aluminium 

Guard & Accessory : Stainless Steel

Compliances

IEC 60529-Degrees of protection provided 

by enclosures

ANSI /ASME B 1.20.1 Pipe threads, General 

purpose(Inch)

ISO 228/1  Pipe threads where pressure-tight 
joints are not made on the threads

ISO 261 Metric screw thread

Technical Data

Voltage Range - AC 110V~240V

Watts Range - Below 200W

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Certification

Certified by KOSHA 

(Korea Occupational Safety & Health Agency)

Weight

9 kg 

Model Number Logic

Series 
Constant 

ISXS

VS
-Vapor proof 
DS
-Dust proof  

Lamp Wattage

10-100W 
20-200W  

00

Voltage

@

60Hz

11-AC110V
12-AC120V
20-AC208V  
22-AC220V
24-AC-240V

00

Mounting Type

PT-Pendant 
CL-Ceiling
4B-40

°

Bracket

9B-90

°

Bracket

00

ex) Incandescent, Vapor proof 90

°

Bracket Mounting, AC240V, 200W ISVS 40 22 9B

Lighting Fixtures

A36 _ A37

Lighting Fixtures

A

catalog_eng-html.html
background image

0

1

2

3

4

5

6

7

8

9

10

.62  .62  .62   .60  .60  .60    .58  .58  .58    .55  .55  55     .53  .53  .53  

.55  .53  .51   .54  .52  .51    .52  .50  .49    .50  .49  .47    .48  .47  .46 

.49  .46  .44   .48  .45  .43    .46  .44  .42    .45  .43  .41    .43  .42  .40 

.44  .35  .32   .43  .40  .37    .42  .39  .36    .40  .38  .36    .39  .37  .35 

.40  .35  .32   .39  .35  .32    .38  .34  .32    .36  .34  .31    .35  .33  .31  

.36  .31  .28   .35  .31  .28    .34  .31  .28    .33  .30  .28    .32  .29  .27  

.32  .28  .25    .32  .28  .25    .31  .27  .25   .30  .27  .24    .29  .26  .24

.29  .25  .22   .29  .25  .22     .28  .25  .21   .28  .24  .22    .27  .24  .22  

.27  .23  .20   .26  .22  .20    .26  .22  .20    .25  .22  .20    .25  .22  .20 

.25  .21  .18   .25  .21  .18    .24  .21  .18    .23  .20  .18    .23  .20  .18  

.23  .19  .17   .23  .19  .17    .22  .19  .17    .22  .19  .17    .21  .18  .16 

.52 

.45 

.39 

.34  

.30 

.26 

.23  

.21

.19 

.17 

.16 

80

70

50

30

10

0

50 30 10

20% Effective Floor Cavity Reflectance

50 30 10 50 30 10 50 30 10 50 30 10

0

%Effective

Ceiling Cavity

Reflectance 1cc

%Wall 

Reflectance 1w

Room Cavity

Ratio RCR

Photometric Data

Incandescent 200W

ZONAL CAVITY METHOD

0
5

10
15
20
25
30
35
40
45

137
143
150
128
135
137
107
107
103
111

50
55
60
65
70
75
80
85
90

-

133
150
103

99
34
15

6
4
2

-

cd/1000 lm

Angle

cd/1000 lm

Angle

SXS Series - For Non Hazard. Dust & Vapor Proof IP65  

Lighting Fixture

Dust & Vapor 
Proof IP65

IEC 60529

Lighting Fixtures

A

Dimensions

Pendant Type

Ceiling Type

Standard Type Reflector

90° Bracket Type

40° Bracket Type

30° Dome Type Reflector

Dimensions (mm) 

catalog_eng-html.html
background image

LEH Series - Ex d II C IP66  

Hand Lamp Lighting

Ex d IIC IP66 

IEC 60079-0,1

IEC 60529

Applications

LEH Series  Hand lamp lighting Fixtures are used ; as portable Hand-lamp where moisture, dirt, dust, 

corrosion and vibration may be present, or IEC 60529  IP66 areas where wind, water, snow or high    
ambient can be expected. 

They can be used in locations made hazardous due to the presence of flammable or explosive gases, 

vapors and combustible dusts as defined by the IEC 60079-0,1. 

Applications include classified areas such as paint manufacturing plants, ammunition facilities, 

oil and gas producing and refining plants, off-shore and dockside installations, tank farms, pipeline 
pumping stations and marine loading and fuel transfer terminals. 

Hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired.

Features

Light sources and wattages to meet specific lighting needs – 20W compact fluorescent and 100W

incandescent. 

Two light sources – Compact fluorescent, incandescent. 

Corrosion resistant – Copper-free aluminum die-cast construction. Baked powder epoxy finish, 

electro-statically applied. Exposed hardware is stainless steel.

Standard Materials

Copper-free Aluminium (Cast Aluminium Alloy) 

Globe : Heat Resistant Glass 

Reflector : High Purity Aluminium 

Guard & Accessory : Stainless Steel 

Compliances

IEC 60079-0  Equipment – General requirements 

IEC 60079-1  Equipment protection by flameproof 
enclosures “d”

ANSI /ASME B 1.20.1 Pipe threads, General 
purpose(Inch)

ISO 228/1  Pipe threads where pressure-tight 
joints are not made on the threads

ISO 261 Metric screw thread

Technical Data

Voltage Range - AC 110V~240V

Watts Range - 20~100W

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Certification

Certified by KOSHA 

(Korea Occupational Safety & Health Agency)

Weight

2.7 kg 

Lighting Fixtures

A38 _ A39

Lighting Fixtures

A

catalog_eng-html.html
background image

Model Number Logic

Lamp Type

I - Incandescent 
C- Compact 

fluorescent 

0

Series 
Constant 

LEH

ex) Compact Fluorescent, AC220V, 20W CLEH 20 22 

Dimensions 

Dimensions (mm) 

Photometric Data

0
5

10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

90
75
75
90
80
75
80
85
85
95
85
85
90

105

90
85
85
85
80

23
23
29
29
34
34
46
51
57
63
68
74
80
80
85
85
85
85
85

cd/1000 lm

ILEH 10 CLEH 20

ANGLE

Lamp
Wattage

02-  20W-C
10-100W-I

00

Voltage

@

60Hz

11-AC110V
12-AC120V
20-AC208V  
22-AC220V
24-AC-240V

00

LEH Series - Ex d II C IP66  

Hand Lamp Lighting

Ex d IIC IP66 

IEC 60079-0,1

IEC 60529

Lighting Fixtures

A

catalog_eng-html.html
background image

LET Series - Ex d II B IP66  

Tank Lighting

Ex d IIB IP66 

IEC 60079-0,1

IEC 60529

Applications

LET Series  Tank lighting Fixtures are designed for installations where an explosive atmosphere 

consisting of a mixture with air of flammable substances in the form of gas, vapor or mist is not likely 
to occur in normal operation but, if it does occur, will persist for a short period only. 

Applications include classified areas such as illuminating stirred tank or storage tank, reactors,     

distillation columns, pipeline flow indicator etc

Features

Wide range of light sources and wattages to meet specific lighting needs –100, 200W  incandescent, 25, 40

and 60W halogen. 

Two light sources –Incandescent, Halogen. 

Corrosion resistant – Copper-free aluminum die-cast construction. Baked powder epoxy finish, electro
statically applied. Exposed hardware is stainless steel. 

Fixing of the fittings are to be done by suitable mounting hard-wares utilizing the mounting base on the

front frame. 

Easy maintenance and installation.

Standard Materials

Copper-free Aluminium (Cast Aluminium Alloy) 

Globe : Heat Resistant Glass 

Reflector : High Purity Aluminium 

Guard & Accessory : Stainless Steel 

Compliances

IEC 60079-0  Equipment – General requirements 

IEC 60079-1  Equipment protection by flameproof 
enclosures “d”

ANSI /ASME B 1.20.1 Pipe threads, General 
purpose(Inch)

ISO 228/1  Pipe threads where pressure-tight 
joints are not made on the threads

ISO 261 Metric screw thread

Technical Data

Voltage Range - AC 110V~240V

Watts Range - 25~200W

Standard Finishes

Spray  (Color : Munsel No. 7.5BG 6/1.5)

Certification

Certified by KOSHA 

(Korea Occupational Safety & Health Agency)

Weight

3 kg 

Model Number Logic

Lamp Type

I - Incandescent 
H- Halogen 

0

Series 
Constant 

LET

ex) Incandescent, AC220V, 200W ILET 20 22   

Lamp Wattage

02-  25W-H
04-40W -H
06-60W -H
10-100W-I 
20-200W-I 

00

Voltage

@

60Hz

11-AC110V
12-AC120V
20-AC208V  
22-AC220V
24-AC-240V

00

Lighting Fixtures

A40 _ A41

Lighting Fixtures

A

catalog_eng-html.html
background image

Dimensions 

Dimensions (mm) 

Photometric Data

0
5

10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

109
118
116
114
109
105

96
77
79
58
47
39
30
21
13

6
2
0
0

442.1

503
427
297
198
152
152
130

91
61
30

0
0
0
0
0
0
0
0

cd/1000 lm

ILEH 20 CLEH 60

ANGLE

LET Series - Ex d II B IP66  

Tank Lighting

Ex d IIB IP66 

IEC 60079-0,1

IEC 60529

Lighting Fixtures

A

catalog_eng-html.html
background image

LEF Series - Ex d II B T3 IP66  

Flood Lighting

Ex d IIB T3 IP66 

IEC 60079-0,1

IEC 60529

Applications

LEF Series  Flood-lighting Fixtures are designed for installations where moisture, dirt, dust, 
corrosion and vibration may be present, or IEC 60529  IP66 areas where wind, water, snow or 

high ambient can be expected. 

They can be used in locations made hazardous due to the presence of flammable or explosive 

gases, vapors and combustible dusts as defined by the IEC 60079-0,1. 

Applications include classified areas such as paint manufacturing plants, ammunition facilities, 

oil and gas producing and refining plants, off-shore and dockside installations, tank farms, 
pipeline pumping stations and marine loading and fuel transfer terminals. 

Hazardous areas, both indoors and outdoors where long life and low maintenance costs are 

desired.

Features

Wide range of light sources and wattages to meet  specific lighting needs –150, 200, 250 and 400W high

pressure sodium (HPS) ; 200, 250 and 400W mercury vapor (MV);175, 250 and 400W metal halide (MH). 

Three light sources –High pressure sodium, metal halide and mercury vapor. 

Corrosion resistant – Copper-free aluminum die-cast construction. Baked powder epoxy finish, 
electro-statically applied. Exposed hardware is stainless steel. 

The body and mounting box are wired with  Flame proof (Ex d II C) type EPF flexible coupling.

The mounting box has a turning base plate on  the top and a large access cover for wiring on the side

Standard Materials

Copper-free Aluminium (Cast Aluminium Alloy) 

Globe : Heat Resistant Glass 

Reflector : High Purity Aluminium 

Guard & Accessory : Stainless Steel 

Options

Fuse – to protect ballast and capacitors against 

abnormal line conditions. 

One fuse required for 120 or 277VAC units 

Two fuses needed for 208,240 or 480VAC units 

Instant re-strike ballast – enables a hot HPS 

lamp to immediately re-strike after a momentary 
loss of arc due to voltage fluctuation or power 
outage. It has no effect on the warm-up period of 
cold lamps (Max 150W HPS only).

Technical Data

Voltage Range - AC 110V~480V

Watts Range - 150~400W

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Certification

Certified by KOSHA 

(Korea Occupational Safety & Health Agency)

Weight

45 kg 

Compliances

IEC 60079-0  Equipment – General requirements 

IEC 60079-1  Equipment protection by flameproof 
enclosures “d”

ANSI /ASME B 1.20.1 Pipe threads, General 
purpose(Inch)

ISO 228/1  Pipe threads where pressure-tight 
joints are not made on the threads

ISO 261 Metric screw thread

Lighting Fixtures

A42 _ A43

Lighting Fixtures

A

catalog_eng-html.html
background image

Dimensions 

Dimensions (mm) 

Photometric Data

0
5

10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

1658

863
390
253
225
188
153
125

73
43
15

5
5
3
3
3
0
0
0

cd/1000 lm

ANGLE

Model Number Logic

Lamp Type

S-HPS (High 
pressure sodium)
M- Metal halide
V- Mercury vapor

0

Series 
Constant 

LEF

Lamp Wattage

15-150W-S
17-175W-M
20-200W-S.V
25-250W -M.S.V
40-400W -M.S.V

00

Voltage

@

60Hz

11-AC110V
12-AC120V
20-AC208V
22-AC220V  
24-AC-240V 
27-AC277V
48-AC480V

00

0

ex) Metal Halide high power factor type, AC220V, 250W MLEF 25 22 P 

P-Omit P if High 
power factor is
not required

LEF Series - Ex d II B T3 IP66  

Flood Lighting

Ex d IIB T3 IP66 

IEC 60079-0,1

IEC 60529

Lighting Fixtures

A

catalog_eng-html.html
background image

LNF Series - Ex nR II T3 IP66  

Flood Lighting

Ex nR II T3 IP66 

IEC 60079-0,15

IEC 60529

Applications

LNF Series  Flood-lighting Fixtures are designed for installations where moisture, dirt, dust, 
corrosion and vibration may be present, or IEC 60529  IP66 areas where wind, water, snow or 

high ambient can be expected. 

They can be used in locations made hazardous due to the presence of flammable or explosive 

gases, vapors and combustible dusts as defined by the IEC 60079-0,15. 

Applications include classified areas such as paint manufacturing plants, ammunition facilities, 

oil  and gas producing and refining plants, off-shore and dockside installations, tank farms, 
pipeline pumping stations and marine loading and fuel transfer terminals. 

Hazardous areas, both indoors and outdoors where long life and low maintenance costs are 

desired.

Features

Wide range of light sources and wattages to meet specific lighting needs –150, 200, 250 and 400W high

pressure sodium (HPS) ; 200, 250 and 400W mercury vapor (MV); 175, 250 and 400W metal halide (MH). 

Three light sources –High pressure sodium, metal halide and mercury vapor. 

Corrosion resistant – Copper-free aluminum die-cast construction. Baked powder epoxy finish, 

electro-statically applied. Exposed hardware is stainless steel. 

The body and mounting box are wired with Increased Safety  (Ex e II) type PVF flexible coupling.

The mounting box has a turning base plate on the top and a large access cover for wiring on the side

Standard Materials

Copper-free Aluminium (Cast Aluminium Alloy) 

Globe : Heat Resistant Glass 

Reflector : High Purity Aluminium 

Guard & Accessory : Stainless Steel 

Options

Fuse – to protect ballast and capacitors against 

abnormal line conditions. 

One fuse required for 120 or 277VAC units 

Two fuses needed for 208, 240 or 480VAC units 

Instant re-strike ballast – enables a hot HPS 

lamp to immediately re-strike after a momentary 
loss of arc due to voltage fluctuation or power 
outage. It has no effect on the warm-up period of 
cold lamps (Max 150W HPS only).

Technical Data

Voltage Range - AC 110V~480V

Watts Range - 150~400W

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Certification

Certified by KOSHA 

(Korea Occupational Safety & Health Agency)

Weight

31 kg

Compliances

IEC 60079-0  Equipment – General requirements 

IEC 60079-15  Construction, test and marking of 
type of protection “n” electrical apparatus 

ANSI /ASME B 1.20.1 Pipe threads, General 
purpose(Inch)

ISO 228/1  Pipe threads where pressure-tight 
joints are not made on the threads

ISO 261 Metric screw thread

Lighting Fixtures

A44 _ A45

Lighting Fixtures

A

catalog_eng-html.html
background image

Dimensions 

Dimensions (mm) 

Photometric Data

0
5

10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

355
180
143
135
135
133
123
120
108

75
45
30
20
13

8
3
0
0
0

cd/1000 lm

ANGLE

Model Number Logic

Lamp Type

S-HPS (High 
pressure sodium)
M- Metal halide
V- Mercury vapor

0

Series 
Constant 

LNF

Lamp Wattage

15-150W-S
17-175W-M
20-200W-S.V
25-250W -M.S.V
40-400W -M.S.V

00

Voltage

@

60Hz

11-AC110V
12-AC120V
20-AC208V
22-AC220V  
24-AC-240V 
27-AC277V
48-AC480V

00

0

ex) High Pressure Sodium, Normal type, AC277V, 400W SLNF 40 27

P-Omit P if High 
power factor is
not required

LNF Series - Ex nR II T3 IP66  

Flood Lighting

Ex nR II T3 IP66 

IEC 60079-0,15

IEC 60529

Lighting Fixtures

A

catalog_eng-html.html
background image

MEMO

Lighting Fixtures

A46 _ A47

Lighting Fixtures

A

catalog_eng-html.html
background image

High Stability and Easy Construction by Advanced Technology

Designed and manufactured by advanced structural analysis, Samwha's boxes are globally

standardized products that guarantee high stability. They are easy to install and construct, 

providing a high cost benefit.

catalog_eng-html.html
background image

Smart  +  Technology  +  Human

Contents

B

B

Enclosures/
Controls/Panels

Enclosures / Controls / Panels

Junction Boxes

Flame-proof Type Enclosure General Technical Descriptions
Flame-proof Type Junction Boxes EJB Series - Ex d II B+H2 T6 
EJB-C Series - Ex d II C T6 

EJB Series - Ex d II B+H2 T6 Junction Boxes
EJB-C Series - Ex d II C T6 Junction Boxes

Increased Safety Type Junction Boxes SIJA Series 
(Copper Free Aluminum) - Ex e II  
SIJB Series (Stainless Steel) - Ex e II  

SIJA Series (Copper Free Aluminum) - Ex e II Junction Boxes
SIJB Series (Stainless Steel) - Ex e II Junction Boxes

Indicators

Flame-proof Type Indicators EIB Series - Ex d II B+H2 T6 
EIB-C Series - Ex d II C T6

EIB Series-Ex d II B+H2 T6 Indicators
EIB-C Series-Ex d II C T6 Indicators
ELC Series Lens Covers

Circuit Breaker Boxes

Flame-proof Type Circuit Breaker Boxes SFCB 5040 & 4030
Series-Ex d II B+H2 T6 / SFCB-C 6529 Series-Ex d II C T6

SFCB 4030 Series-Ex d II B+H2 T6 
SFCB 5040 Series-Ex d II B+H2 T6
SFCB-C 6529 Series -Ex d II C T6

Controls

Flame-proof Type Controls  SEPB Series Combination Operating
Switches-Ex d II C T6 / SETS Series General Use Snap Switches-
Ex d II B T6 / SEC Series Control Stations-Ex d II B T6 / SECB Series
Custom-built Indicator & Control Boxes-Ex d II B+H2 T6

SEPB Series Combination Operating Switches-Ex d II C T6  
SETS Series General Use Snap Switches-Ex d II B T6  
SEC Series Control Stations-Ex d II B T6
SECB Series Custom-built Indicator & Control Boxes-Ex d II B+H2 T6

Electrical Products

Flame-proof Type Electrical Products SLS Series Micro & Limit
Switches-Ex d II B T6 / SEPR Series Receptacles & Plugs-Ex d II
B+H2* T6 / SDPR Series Receptacles & Plugs-Non-hazardous Area
/ ELES Series Exit Sign -Ex d II B T6 / SEPR Series Receptacles &
Plugs-Ex d II B+H2* T6 

SLS Series Micro & Limit Switches-Ex d II B T6  
SEPR Series Receptacles & Plugs-Ex d II B+H2* T6
SDPR Series Receptacles & Plugs-Non-hazardous Area Receptacles &
Plugs (Non-hazardous.)
ELES Series Exit Sign

Panels

Flame-proof Type Panel System : SEPD &-C or SECP &-C Series
Flame-proof Type Custom-built Panels General Technical Descriptions

Panels(Circuit Breaker Panels)

Flame  Proof Type Custom-built Panels General Technical Descriptions
SEPD Series - Ex d II B + H2 T6 Custom-built Panel Boards
SECP Series - Ex d II B + H2 T6 Custom-built Control Panels
SEPD-C Series - Ex d II C T6 Custom-built Panel Boards
SECP-C Series - Ex d II C T6 Custom-built Control Panels
Switch Rack Assemblies

B2

B3
B4
B6

B9
B10
B11

B14
B15
B16
B18

B19
B20
B22
B24

B26
B28
B30
B32
B34

B37
B38
B40

B43
B45

B46

B48
B49
B52
B55
B59
B62

catalog_eng-html.html
background image

B

Junction Boxes

Enclosures / Controls / Panels

Flame-proof Type Enclosure General Technical Descriptions

Flexible Foot Installation

Detachable mounting feet provide mounting flexibility. (Picture 1,2)

No need to replace enclosure if mounting feet art broken.

Four separate mounting lugs furnished, bolted to the body casting.

Two lugs may be used, at top and bottom center, for pole mounting. (Picture 3)

Grounding

Internal and external ground terminations simplify grounding requirements

Because of dangerous electrical shock to the equipment operator SAMWHA products are provided

with means of grounding depends upon the particular style being used.

Maintenance & Caution Note

This apparatus can be used in the hazardous areas indicated on the plate so that use in the  other areas 

is prohibited. (A plate is attached on the exterior of the apparatus.)

Power should be turned off to open the apparatus for Installation, inspection and Maintenance, 

and a proper security measures must be conducted to keep power off while it is open.

It is requested to exercise an extra caution to prevent damages to the junction parts at openings 

and closings, and to tighten bolts completely with a tool to avoid sticking of things on them.

An impact on or a dropping of the apparatus causes a lowering of quality so, a special handing is demanded.

The rated voltage indicated on the apparatus should be observed.

Please inform SAMWHA if any problems related with the apparatus.

Mounting Lugs

Pole

Minimum Centers for Drilled and Tapped Openings and Hubs

#16/M16
#22/M20
#28/M25
#36/M32
#42/M40
#54/M50
#70/M63
#82/M75

#104/M90

39
44

47.5
56.5
62.5

71

80.5

87

103.5

49

52.5
61.5
67.5

76

85.5

92

108.5

56
65
71

79.5

89

95.5

112

72
78

86.5

96

102.5

119

84

92.5

102

108.5

125

99

108.5

115

131.5

118

124.5

141

129

145.5

162

#16/M16

#22/M20

#28/M25

#36/M32

#42/M40

#54/M50

#70/M63

#82/M75

#104/M90

Hub Design

Drilled and tapped conduit openings will be evenly spaced and 

located in the area indicated on the location chart. Critical conduit 
opening locations may be indicated by supplying a diagram similar 
to the one shown at below indicating critical dimensions and locations.

Specific conduit openings must be located dimensionally from box 
centerlines to conduit centerlines and from outside back surface of box 

to conduit centerline.

Drawing indicates position as looking
into Hub opening of box

Picture 1

Picture 2

Picture 3

catalog_eng-html.html
background image

Enclosures / Controls / Panels

B2 _ B3

Enclosures

/

Controls

/Panels

B

Copper Free 

Aluminum

Flexible Foot 

Installation

Flame-proof Type Junction Boxes EJB Series -Ex d II B+H2 T6 
EJB-C Series-Ex d II C T6 

Flame-proof Type Junction Boxes EJB Series – Ex d II B + H2 T6 

Cl. I, Div. 1 & 2, Groups B*, C, D

NEMA 3, 3R, 4**, 4X**

Zone 1, Zone 2

II 2G Ex d II B+H2* IP66**

Explosion-proof 

Rain-tight 

Dust-tight 

Water-tight**

Corrosion Resistant** 

Flame-proof Type Junction Boxes EJB-C Series – Ex d II C T6 

Cl. I, Div. 1 & 2, Groups A, B, C, D 

NEMA 3, 3R, 4*, 4X* 

Zone 1, Zone 2 

II 2G Ex d II C IP65*

Explosion-proof 

Rain-tight 

Water-tight

Corrosion Resistant

Specification of  Junction Boxes

1

2

3

4

5

6

7

MODEL NO.

CERTIFICATED

IP GRADE

TEMPERATURE

HUMIDITY

ALTITUDE

BASIC FINISH

KOSHA (Korea Occupational Safety & Health Agency)

IP65 or IP66

-20

~ 40

95%

1000 m

Spray (Color : Munsel No. 7.5BG 6/1.5)

EJB Series

EJB -C Series

No.

Ex d II C T6 type

Ex d II+H2 T6 type

Specification

EJB Series

EJB-C Series

catalog_eng-html.html
background image

B

Junction Boxes

Enclosures / Controls / Panels

EJB Series -Ex d II B+H2 T6  

Junction Boxes

Explosion-proof
Rain-tight
Dust-tight / Water-tight**
Corrosion Resistant**

Cl. I, Div. 1 & 2, Groups B*, C, D
NEMA 3, 3R, 4**, 4X**
Zone 1, Zone 2 
II 2G Ex d II B+H2* IP66**

Copper Free 

Aluminum

Flexible Foot 

Installation

As a junction or pull box.

To provide enclosures for splices and branch circuit taps.

For housing terminal blocks, relays and other electrical devices.

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations.

Where exposure to frequent or heavy rain, water, spray, moisture, and humidity is common, 

such as: offshore drilling facilities, cooling towers, coal preparation and handling facilities  
and sewage and waste water treatment plant.

In areas which are hazardous due to the presence of hydrogen or gases and vapors of 

equivalent hazard such as found in process industries and gas manufacturing plants.

Applications

EJB Series junction boxes are used in threaded rigid conduit systems in hazardous areas :

Features

SAMWHA supplies explosion protected terminal enclosures in various sizes, as individual enclosures or as   

terminal  box combinations.

Series EJB terminal enclosures, made of ASTM B26 356 T6 as standard.

Series EJB terminal enclosures are supplied as standard with series SH-STB terminals from SAMWHA.

Terminals from other manufacturers, (e.g.Weidmuller, Phoenix or Wago) can be fitted if required. 

Special Silicon or Neoprene cover 0-ring gasket provides a water seal to meet IP65 requirements, 

and provides superior protection for enclosed equipment against water/corrosion.

Ground joint cover opening provides maximum opening for pulling wires or mounting equipment.

Walls of bodies may be drilled and tapped for conduit entries as shown in listings.

Stud bolts in diagonally opposite corners of body aid in aligning cover to body during installation. 

(not furnished with hinged covers)

Square corners of enclosure body provide maximum interior space and area for conduit openings.

Internal grounding lug provides a means to ground enclosed equipment.

Enclosures are machined for field installed mounting plates.

Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are broken.

Optional stainless steel hinges provide convenient and easy access for inspection, maintenance and systems

changes.

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Gasket-Silicon or Rubber

Hinges-Stainless Steel

Middle plate-Bakelite plate

Standard Finishes

Natural or Epoxy painted (Munsell No. 7.5BG 6/1.5)

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500 / NEMA 4, 4X / IEC 60529

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

catalog_eng-html.html
background image

Enclosures

/

Controls

/Panels

B

Enclosures / Controls / Panels

B4 _ B5

Options

Diagram Pocket

Hinged covers : Hinges mounted on left.

Spring return cover bolts : Stainless steel spring.

EJB 1510

EJB 2015

EJB 2322

EJB 3022

EJB 3030H*

EJB 4030

EJB 4030H*

EJB 5040

EJB 5040H*  **

EJB 5050H*

EJB 6040

EJB 7060H*

150

200

230

300

300

400

400

500

500

500

600

700

100

150

220

220

300

300

300

400

400

500

400

600

T6

T6

T6

T6

T6

T6

T6

T6

T6

T6

T6

T6

-

-

-

-

IP65

-

-

-

IP66

IP65

-

IP65

CAT.NO.

DIMENSIONS (MM)

WIDTH

HEIGHT

TEMPERATURE GRADE

IP GRADE

‘ * ’ - II B + Hydrogen gas

’ ** ’ – IP grade-IP 66

Selection Table

catalog_eng-html.html
background image

B

Junction Boxes

Enclosures / Controls / Panels

EJB-C Series -Ex d II C T6 

Junction Boxes

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D
NEMA 3, 3R, 4*, 4X*
Zone 1, Zone 2
II 2G Ex d II C IP65*

Copper Free 

Aluminum

Flexible Foot 

Installation

As a junction or pull box.

To provide enclosures for splices and branch circuit taps.

For housing terminal blocks, relays and other electrical devices.

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations.

Where exposure to frequent or heavy rain, water, spray, moisture, and humidity is common, 

such as: offshore drilling facilities, cooling towers, coal preparation and handling facilities  
and sewage and waste water treatment plant.

Applications

EJB-C junction boxes are used in threaded rigid conduit systems in hazardous areas :

Features

SAMWHA supplies explosion protected terminal enclosures in various sizes, as individual enclosures or as 

terminal  box combinations.

Series EJB-C terminal enclosures, made of ASTM B26 356 T6 as standard.

Series EJB-C terminal enclosures are supplied as standard with series SH-STB terminals from SAMWHA.

Terminals from other manufacturers, (e.g.Weidmuller, Phoenix or Wago) can be fitted if required. 

Special Silicon or Neoprene cover 0-ring gasket provides a water seal to meet IP65 requirements, 

and provides superior protection for enclosed equipment against water/corrosion.

Ground joint cover opening provides maximum opening for pulling wires or mounting equipment.

Walls of bodies may be drilled and tapped for conduit entries as shown in listings.

Square corners of enclosure body provide maximum interior space and area for conduit openings.

Internal grounding lug provides a means to ground enclosed equipment.

Enclosures are machined for field installed mounting plates.

Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are broken.

Standard Finishes

Natural or Epoxy painted (Munsell No. 7.5BG 6/1.5)

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Gasket-Silicon or Rubber

Middle plate-Bakelite plate

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500 / NEMA 4, 4X / IEC 60529

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

Option

Diagram Pocket

catalog_eng-html.html
background image

Enclosures

/

Controls

/Panels

B

Enclosures / Controls / Panels

B6 _ B7

Flexible Foot Installation

Detachable mounting feet provide mounting flexibility. (Picture 1,2)

No need to replace enclosure if mounting feet art broken.

Four separate mounting lugs furnished, bolted to the body casting.

Two lugs may be used, at top and bottom center, for pole mounting. (Picture 3)

EJB-C 2019

EJB-C 2520

EJB-C 3530

EJB-C 4035

EJB-C 5040*

EJB-C 5550

200

250

350

400

500

500

190

200

300

350

400

500

T6

T6

T6

T6

T6

T6

-

-

-

-

IP65

-

CAT.NO.

DIMENSIONS (MM)

WIDTH

HEIGHT

TEMPERATURE GRADE

IP GRADE

’ *  ’ IP grade-IP 65

Selection Table

Grounding

Internal and external ground terminations simplify grounding requirements

Because of dangerous electrical shock to the equipment operator SAMWHA EJB-C Series are provided 

with means of grounding depends upon the particular style being used.

ዽ૑ਜ਼༺ྦ႖લຫ

ႜዶ

૬ગ

:

ጁગ

฀ጭ

:

႞Ⴎ

ஶဵၩ

:2

0

0

.

.

.

႞Ⴎ

:

External Grounding

Internal Grounding   

Grounding

Mounting Lugs

Pole

30°

Picture 1

Picture 2

Picture 3

catalog_eng-html.html
background image

B

Junction Boxes

Enclosures / Controls / Panels

Gasket 
(Neoprene or 
Silicone)

Minimum Centers for Drilled and Tapped Openings and Hubs

#16/M16

#22/M20

#28/M25

#36/M32

#42/M40

#54/M50

#70/M63

#82/M75

#104/M90

39

44

47.5

56.5

62.5

71

80.5

87

103.5

49

52.5

61.5

67.5

76

85.5

92

108.5

56

65

71

79.5

89

95.5

112

72

78

86.5

96

102.5

119

84

92.5

102

108.5

125

99

108.5

115

131.5

118

124.5

141

129

145.5

162

#16/M16

#22/M20

#28/M25

#36/M32

#42/M40

#54/M50

#70/M63

#82/M75

#104/M90

Front View

Section View

Terminals ;
SH-STB 6U

Terminals ;
SH-STB 6U

External
Grounding 
Lug

External
Grounding 
Lug

Internal
Grounding
PE Cannel

Mounting
Lug : 4-

Ø

13

Duct

Duct

Interior View 

IP Packing System

Example EJB-C 5040

EJB-C Series -Ex d II C T6 

Junction Boxes

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D
NEMA 3, 3R, 4*, 4X*
Zone 1, Zone 2
II 2G Ex d II C IP65*

Hub Design

Drilled and tapped conduit openings will be evenly spaced  and located in the area indicated on the location
chart. Critical conduit opening locations may be indicated by supplying a diagram similar to the one shown
at below indicating critical dimensions and locations.

Specific conduit openings must be located dimensionally from box centerlines to conduit centerlines 
and from outside back surface of box to conduit centerline.

Copper Free 

Aluminum

Flexible Foot 

Installation

catalog_eng-html.html
background image

Enclosures

/

Controls

/Panels

B

Enclosures / Controls / Panels

B8 _ B9

Specification of  Junction Boxes

1

2

3

4

5

6

7

MODEL NO.

MATERIALS

CERTIFICATED

IP GRADE

TEMPERATURE

HUMIDITY

ALTITUDE

KOSHA (Korea Occupational Safety & Health Agency)

IP 65

-20

~ 40

95%

1000 m

SIJA Series

SIJB Series

Copper Free Aluminum

Stainless Steel

Spray (Color : Munsel No. 7.5BG 6/1.5)

Natural

No.

Ex e II type

Specification

8

BASIC FINISH

Increased Safety Type Junction Boxes SIJA Series (Copper Free Aluminum) – Ex e II  
SIJB Series (Stainless Steel) – Ex e II  

Increased Safety Type Junction Boxes SIJA Series 

(Copper Free Aluminum) – Ex e II 

Cl. I, Div. 1 & 2 Groups A, B, C, D

NEMA 4, 4X

Zone 1, Zone 2

II 2G Ex e II IP65

Increased safety type

Rain-tight

Water-tight

Corrosion Resistant

Increased Safety Type Junction Boxes SIJB Series (Stainless Steel) – Ex e II

Cl. I, Div. 1 & 2 Groups A, B, C, D

NEMA 4, 4X

Zone 1, Zone 2

II 2G Ex e II IP65

Increased safety type

Rain-tight

Water-tight

Corrosion Resistant

SIJA Series

SIJB Series

catalog_eng-html.html
background image

B

Junction Boxes

Enclosures / Controls / Panels

SIJA Series (Copper Free Aluminum) – Ex e II 

Junction Boxes

Increased safety type
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2 Groups A, B, C, D
NEMA 4, 4X
Zone 1, Zone 2
II 2G Ex e II IP65

Copper Free 

Aluminum

Flexible Foot 

Installation

With STB 

Terminal Block 
Series Standard

As a junction or pull box.

For Zone 1 & 2, Increased Safety type (Ex e II )

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations

Where exposure to frequent or heavy rain, water, spray, moisture, and humidity is common; 

such as: offshore drilling facilities, cooling towers, coal preparation and handling 
facilities  and sewage and waste water treatment plant.

In areas which are hazardous due to the presence of hydrogen or gases and vapors of 
equivalent hazard such as found in process industries and gas manufacturing plants. 

Applications

SIJA Series Terminal Enclosures are used with Increased Safety type Terminals.

Features

Series SIJA terminal enclosures are supplied as standard with series SH-STB terminals from SAMWHA 

(Increased Safety type). 

Terminals from other manufacturers, (e.g.Weidmuller, Phoenix or Wago) can be fitted if required. 

Special Silicon or Neoprene cover gasket provides a water seal to meet IP65 requirements, and provides 

superior protection for enclosed equipment against water/corrosion.

Series SIJA terminal enclosures, made of ASTM B26 356 T6 as standard.

Ground joint cover opening provides maximum opening for pulling wires or mounting equipment.

Walls of bodies may be drilled and tapped for conduit entries as shown in listings.

Square corners of enclosure body provide maximum interior space and area for conduit openings.

Internal grounding lug provides a means to ground enclosed equipment.

Enclosures are machined for field installed mounting plates.

Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are broken.

Standard Materials

Copper-free Aluminum

Accessory : Stainless steel

Gasket-Silicon or Rubber

Hinges-Stainless steel

Middle plate-Bakelite plate

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-7  Equipment protection by Increased 

Safety “e”

ANSI/ASME B 1.20.1 Pipe threads, General 

purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight     
joints are not made on the threads

ISO 261 Metric screw threads

NEC 500 / NEMA 4, 4X / IEC 60529

Options

Drain & Breather

Handle & Hinge ( Standard or Heavy duty type)

Diagram Pocket / Flexible foot

Name plate - Stainless Steel or Acryl plate or Aluminum

Certification

Certified KOSHA 
(Korea Occupational Safety & Health Agency)

Terminals Arrangement

SIJA Series can be fitted with terminals 20A - 6SQ
(SAMWHA STB-6U Standard) as follows;

SIJA 4030
SIJA 4040
SIJA 5040

T6
T6
T6

IP65
IP65
IP65

400
400
300

300
400
400

IP

GRADE

TEMPERATU

RE GRADE

CAT.NO.

DIMENSIONS (MM)

WIDTH

HEIGHT

Selection Table 

STB 015L

STB 4U
STB 6U

75
60
60

105

90
90

2.5SQ

4SQ
6SQ

50
60
60

SIJA

5040

SIJA

4040

SIJA

4030

TERMINAL SPEC.

catalog_eng-html.html
background image

Enclosures

/

Controls

/Panels

B

Enclosures / Controls / Panels

B10 _ B11

Increased safety type
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2 Groups A, B, C, D
NEMA 4, 4X
Zone 1, Zone 2
II 2G Ex e II IP65

SIJB Series (Stainless Steel) – Ex e II 

Junction Boxes

Stainless Steel

With STB 

Terminal Block 
Series Standard

For Zone 1 & 2, Increased Safety type (Ex e II )

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations

Where exposure to frequent or heavy rain, water, spray, moisture, and humidity is common; 

such as : offshore drilling facilities, cooling towers, coal preparation and handling facilities

and sewage and waste water treatment plant.

In areas which are hazardous due to the presence of hydrogen or gases and vapors of 

equivalent hazard such as found in process industries, gas manufacturing plants.

Applications

SIJB Series Terminal Enclosures are necessary if the length of a cable must be extended or the leads of
various switching, signal and monitoring devices must be routed together in a common control cable to
one controller or control room.

SIJB Series Terminal Enclosures are used with Increased Safety type Terminals.

Features

SAMWHA supplies explosion protected terminal enclosures in various sizes, as individual enclosures or as 

terminal  box combinations.

Series SIJB terminal enclosures, made of ASTM A240 Gr. 304 as standard, can be made of ASTM 

A240 Gr.316 or Gr.316L if required.

Series SIJB terminal enclosures are supplied as standard with series SH-STB terminals from SAMWHA 

(Increased Safety type). 

Terminals from other manufacturers,(e.g. Weidmuller, Phoenix or Wago) can be fitted if required.

Special Silicon or Neoprene cover gasket provides a water seal to meet IP65 requirements, and provides 

superior protection for enclosed equipment against water/corrosion.

Optional stainless steel hinges provide convenient and easy access for inspection, maintenance 

and systems changes.

Cable entries, are mounted according to order, are fitted to order with four  types as follows:

Type 1 - Welding Conduit Hub / Type 2 - Cable Gland Opening / Type 3 - Metal Cable Entries 
(They are screwed into Stainless Steel plates.) / Type 4 - Conduit Hub Opening

Options

Drain & Breather

Handle & Hinge (Standard or Heavy duty type)

Diagram Pocket

Name plate - Stainless Steel or Acryl plate or Aluminum

Wall Mounting Bracket - Fork shaped type or 
Pearl shaped type or Std.

Terminal mounting plate - Stainless Steel or Bakelite

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-7  Equipment protection by Increased Safety “e”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500 / NEMA 4, 4X / IEC 60529

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

Standard Materials

Stainless Steel

Accessory : Stainless Steel

Gasket-Silicon or Rubber

Hinges-Stainless Steel

Middle plate-Bakelite plate

catalog_eng-html.html
background image

B

Junction Boxes

Enclosures / Controls / Panels

Grounding

Internal and external ground terminations simplify grounding requirements.

Because of dangerous electrical shock to the equipment operator SAMWHA SIJB Series are provided with 

means of grounding depends upon the particular style being used.

IP Packing System

Interior Front View 

Dimensions

SIJB 2525

SIJB3030

SIJB4040

SIJB 5050

SIJB6050

SIJB6161

SIJB7550

SIJB8060

250

300

400

500

600

610

750

800

250

300

400

500

500

610

500

600

174.5

174.5

174.5

174.5

174.5

174.5

174.5

174.5

200

200

300

400

500

510

650

800

290

340

440

540

540

650

540

640

200

200

200

200

200

200

200

200

A

B

C

D

E

F

Side View

Front View

Picture 2
Blank hole type

Picture 3
Fork shaped type

Picture 4
Pearl shaped type

Cover Fix
bolts

Gasket
(Neoprene or
Silicone)

Weld-bolts for
External & Internal
Grounding 

Weld-bolts for
Terminal
mounting plate 

Weld-nut

Internal Grounding

Weld-nut

Hinge

Duct

Terminals

Fork shaped mounting bracket

Rod bar

Mounting hole
2-

Ø

13~12

DIN TS35 Channel

Terminal
mounting plate
(stainless steel)

External Grounding

Example SIJB 5050 60p terminals

Installations 

Four separate mounting lugs, are welded to the 
body,  provide firmly mounting. (Picture 1) 

Mounting lugs, are mounted according to order, 
are fitted  to order with three types as follows ;  
Type 1 – Blank hole type – Standard (Picture 2)
Type 2 – Fork shaped type – For Mounting  

flexibility (Picture 3)

Type 3 – Pearl shaped type – For convenience 
installation (Picture 4)

Mounting Lugs

Mounting Lugs

SIJB Series (Stainless Steel) – Ex e II 

Junction Boxes

Increased safety type
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2 Groups A, B, C, D
NEMA 4, 4X
Zone 1, Zone 2
II 2G Ex e II IP65

Stainless Steel

With STB 

Terminal Block 
Series Standard

Picture 1

Welding Point 

catalog_eng-html.html
background image

Enclosures

/

Controls

/Panels

B

Enclosures / Controls / Panels

B12 _ B13

STB 015L

STB 4U

STB 6U

2.5SQ

4SQ

6SQ

10

10

10

30

20

20

75

60

60

105

90

90

150

180

180

150-140

120-180

120-180

195-175

160-225

160-225

210-250

270-300

270-300 

TERMINAL SPEC.

SIJB 2525

SIJB 3030

SIJB 4040

SIJB 5050

SIJB 6161

SIJB 6050

SIJB 7550

SIJB 8060

Cable Entries Design 

Cable entries, are mounted according to order, are fitted to order with four types as follows: 

Maximum Quantity for Cable Entries 

Terminals Arrangement

SIJB Series can be fitted with terminals 20A - 6SQ (SAMWHA STB-6U Standard) as follows ; 

SIJB2525

SIJB3030

SIJB4040

SIJB5050

SIJB6161

SIJB6050

SIJB7550

SIJB8060

All

All

All

All

All

A or C

B or D

A or C

B or D

A or C

B or D

18

28

38

48

58

58

48

74

48

78

58

14

17

23

29

35

35

29

44

29

47

35

11

14

20

24

30

29

24

38

24

41

29

5

7

9

12

15

15

12

19

12

21

15

5

6

8

10

13

13

10

16

10

18

13

2

3

3

5

6

5

5

7

5

8

5

2

2

3

4

5

4

4

6

4

6

4

1

2

3

3

4

4

3

5

3

5

4

1

1

2

3

3

3

3

4

3

4

3

Model No.

NPT OR PF

#16

#22

#28

#36

#42

#54

#70

#82

#104

Metric thread

M16

M20

M25

M32

M40

M50

M63

M75

M90

Cable Entries Arrangement

Cable entries will be evenly spaced and located 

in the area indicated on the location chart. 

Critical cable entries locations may be indicated 

by  supplying a diagram similar to the one shown 
at right  indicating critical dimensions and locations.

Specific cable entries must be located dimensionally

from box centerlines to conduit centerlines.

A

C

B

D

Welding Joint 

Hub(Stainless Steel)

Blank Hole

Cable Gland

Conduit Hub

Lock Nut Packing

Cable Gland 

Hub Thread

Welding Joint 

Lock Nut Packing

Strengthen Plate

Lock Nut

Drawing indicates position as looking into Hub opening of box

Type 1 – Welding Conduit Hub

Type 3 – Metal Cable Entries  (Screwed into Stainless Steel plates) 

Type 4 – Conduit Hub Opening 

Type 2 – Cable Gland Opening

catalog_eng-html.html
background image

B

Indicators

Enclosures / Controls / Panels

Flexible Foot 

Installation

With ELC 

Lens Covers 
Series

Flame-proof Type Indicators 
EIB Series - Ex d II B+H2 T6 
EIB-C Series - Ex d II C T6

Flame-proof Type Indicators EIB Series–with ELC Lens Cover Series

Cl. I, Div. 1 & 2, Groups B, C, D

NEMA 4, 4X 

II 2G Ex d II B+H2 IP 65

Explosion-proof

Rain-tight 

Water-tight

Corrosion Resistant

Flame-proof Type Indicators 

EIB-C

Series–with ELC Lens Cover Series

Cl. I, Div. 1 & 2, Groups A, B, C, D 

NEMA 4, 4X 

II 2G Ex d II C IP 65

Explosion-proof

Rain-tight 

Water-tight

Corrosion Resistant

Specification of  Indicators

1

2

3

4

5

6

7

MODEL NO.

CERTIFICATED

IP GRADE

TEMPERATURE

HUMIDITY

ALTITUDE

BASIC FINISH

KOSHA (Korea Occupational Safety & Health Agency)

IP 65

-20

~ 40

95%

1000 m

Spray(Color : Munsel No. 7.5BG 6/1.5)

EIB Series

EIB -C Series

No.

Ex d II C T6 type

Ex d IIB+H2 T6 type

Specification

EIB Series

EIB-C Series

catalog_eng-html.html
background image

Enclosures / Controls / Panels

B14 _ B15

Enclosures

/

Controls

/Panels

B

EIB Series - Ex d II B+H2 T6   

Indicators

Explosion-proof
Rain-tight
Water-tight
Corrosion resistant

Cl. I, Div. 1 & 2, Groups B, C, D
NEMA 4, 4X 
Zone 1, Zone 2
II 2G Ex d II B+H2  IP65

Copper Free 

Aluminum

With ELC 
Lens Covers 
Series

Silicon or  

Neoprene Gasket

Flexible Foot 
Installation

For use to display inside (ammeters, voltmeters, watt- meters, var-meters,  power-factor meters, 
tachometer, indicators, pressure controls, temperature control etc.)  

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations.

In areas which are hazardous due to the presence of hydrogen or gases and vapors of equivalent 
hazard such as found in process industries and gas manufacturing plants. 

Applications

EIB Series Indicators are used with ELC Series in hazardou s areas: 

Features

EIB Indicators provides explosion protection and broad sight in three sizes. 

Series EIB terminal enclosures, made of ASTM B26 356 T6 as standard. 

Special Silicon or Neoprene cover 0-ring gasket provides a water seal to meet IP65 requirements, 

and provides superior protection for enclosed equipment against water/corrosion.

Ground joint cover opening provides maximum opening for pulling wires or mounting equipment.

Walls of bodies may be drilled and tapped for conduit entries as shown in listings.

Square corners of enclosure body provide maximum interior space and area for conduit openings.

Internal grounding lug provides a means to ground enclosed equipment.

Enclosures are machined for field installed mounting plates.

Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are broken.

Standard Finishes

Natural or Epoxy painted (Munsell No. 7.5BG 6/1.5)

Option 

Diagram Pocket 

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Heat Resistant Glass 

Gasket-Silicon or Rubber

Middle plate-Bakelite plate

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500

NEMA 4, 4X 

IEC 60529

EIB 4030

EIB 4030

EIB 5040A
EIB 5040B
EIB 6060A
EIB 6060B
EIB 6060C

T6
T6
T6
T6
T6
T6

IP65
IP65
IP65
IP65
IP65
IP65

400
500
500
600
600
600

300
400
400
600
600
600

ELC 92
ELC 92
ELC 120
ELC 92
ELC 120
ELC 200

IP GRADE

TEMPERATURE

GRADE

GLASS COVERS

CAT.NO.

DIMENSIONS (MM)

WIDTH

HEIGHT

Selection Table 

EIB 5040B

EIB 6060C 

EIB 6060A

catalog_eng-html.html
background image

B

Indicators

Enclosures / Controls / Panels

EIB-C Series - Ex d II C T6  

Indicators

Copper Free 

Aluminum

With ELC 
Lens Covers 
Series

Silicon or  

Neoprene Gasket

Flexible Foot 

Installation

For use to display inside (ammeters, voltmeters, watt- meters, var-meters,  power-factor meters, 
tachometer , indicators, pressure controls, temperature control etc.)  

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations.

In areas which are hazardous due to the presence of hydrogen or gases and vapors of equivalent 
hazard such as found in process industries and gas manufacturing plants. 

Applications

EIB-C Series Indicators are used with ELC Series in hazard ous areas :

Features

EIB-C Indicators provides explosion protection and broad sight in three sizes. 

Series EIB-C terminal enclosures, made of ASTM B26 356 T6 as standard. 

Special Silicon or Neoprene cover 0-ring gasketprovides a water seal to meet IP65 requirements, 

and provides superior protection for enclosed equipment against water/corrosion.

Ground joint cover opening provides maximum opening for pulling wires or mounting equipment.

Walls of bodies may be drilled and tapped for conduit entries as shown in listings.

Square corners of enclosure body provide maximum interior space and area for conduit openings.

Internal grounding lug provides a means to ground enclosed equipment.

Enclosures are machined for field installed mounting plates.

Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are broken.

Standard Finishes

Natural or Epoxy painted (Munsell No. 7.5BG 6/1.5)

Option 

Diagram Pocket 

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Heat Resistant Glass 

Gasket-Silicon or Rubber

Middle plate-Bakelite plate

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500

NEMA 4, 4X / IEC 60529

EIB-C 2520

EIB-C 3530A
EIB-C 3530B

T6
T6
T6

IP65
IP65
IP65

250
350
350

200
300
300

ELC 120
ELC 92
ELC 200

IP GRADE

TEMPERATURE

GRADE

GLASS COVERS

CAT.NO.

DIMENSIONS (MM)

WIDTH

HEIGHT

Selection Table 

Explosion-proof
Rain-tight
Water-tight
Corrosion resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D
NEMA 4, 4X 
Zone 1, Zone 2
II 2G Ex d II C IP65

EIB-C 3530A 

EIB-C 3530B

EIB-C 2520

catalog_eng-html.html
background image

Enclosures / Controls / Panels

B16 _ B17

Enclosures

/

Controls

/Panels

B

Flexible Foot Installation

Detachable mounting feet provide mounting flexibility. (Picture 1,2)

No need to replace enclosure if mounting feet art broken.

Four separate mounting lugs furnished, bolted to the body casting.

Two lugs may be used, at top and bottom center, for pole mounting. (Picture 3)

Hub Design

Drilled and tapped conduit openings will be evenly spaced and 

located in the area indicated on the location chart. Critical conduit 
opening locations may be indicated by supplying a diagram similar 
to the one shown at below indicating critical dimensions and locations.

Specific conduit openings must be located dimensionally from box 
centerlines to conduit centerlines and from outside back surface of box 

to conduit centerline.

Drawing indicates position as 

looking into Hub opening of box

Minimum Centers for Drilled and Tapped Openings and Hubs

#16/M16

#22/M20

#28/M25

#36/M32

#42/M40

#54/M50

#70/M63

#82/M75

#104/M90

39

44

47.5

56.5

62.5

71

80.5

87

103.5

49

52.5

61.5

67.5

76

85.5

92

108.5

56

65

71

79.5

89

95.5

112

72

78

86.5

96

102.5

119

84

92.5

102

108.5

125

99

108.5

115

131.5

118

124.5

141

129

145.5

162

#16/

M16

#22/

M20

#28/

M25

#36/

M32

#42/

M40

#54/

M50

#70/

M63

#82/

M75

#104/

M90

IP Packing System

Gasket 
(Neoprene or 
Silicone)

A

C

B

D

Mounting Lugs

Pole

30°

Picture 1

Picture 2

Picture 3

catalog_eng-html.html
background image

B

Indicators

Enclosures / Controls / Panels

ELC Series  

Lens Covers

Copper Free 

Aluminum

Heat Resistant       
Glass

Silicon or  

Neoprene Gasket

To display ammeters, voltmeters, watt-meters, var-meters,  power-factor meters, tachometer, 
indicators, pressure controls, temperature control etc.

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations.

In areas which are hazardous due to the presence of hydrogen or gases and vapors of equivalent 
hazard such as found in process industries and gas manufacturing plants. 

Applications

ELC Series Lens Covers are used in hazardous areas :

Features

ELC lens covers provides explosion protection and broad sight in three sizes.

ELC lens covers series are made of ASTM B26 356 T6 as standard.   

Special Silicon or Neoprene cover 0-ring gasket provides a water seal to meet IP65 requirements, 

and provides superior protection for enclosed equipment against water/corrosion.

Standard Finishes

Natural or Epoxy painted (Munsell No. 7.5BG 6/1.5)

Standard Materials

Copper-free Aluminum

Heat Resistant Glass 

Gasket-Silicon or Neoprene

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

NEC 500 / NEMA 4, 4X / IEC 60529

Dimensions

GLASS DIAMETER

OUTDIAMETER

THREADS LENGTH

THREADS SIZE

PROTRUTION

92

160

45

Ø143*11G

36

120

200

45

Ø183*11G

41

190 

300 

45 

Ø270*11G 

50 

CAT. NO.

ELC 92

ELC 120

ELC 200 

DIMENSIONS (MM) 

92

160

Explosion-proof
Rain-tight
Water-tight
Corrosion resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D
NEMA 4, 4X 
Zone 1, Zone 2
II 2G Ex d II C IP65

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

catalog_eng-html.html
background image

Enclosures / Controls / Panels

B18 _ B19

Enclosures

/

Controls

/Panels

B

Flexible Foot 

Installation

Flame-Proof Type Circuit Breaker Boxes 
SFCB 5040 & 4030 Series - Ex d II B+H2 T6 
SFCB-C 6529 Series - Ex d II C T6

Flame-proof Type Circuit Breaker Box SFCB 4030 Series – 60AF or 100AF, 100A Max     

SFCB 5040 Series – 225AF or 400AF, 255A Max 

Cl. I, Div. 1 & 2, Groups B, C, D

NEMA 4, 4X 

II 2G Ex d II B+H2 IP 65

Explosion-proof 

Rain-tight 

Water-tight

Corrosion Resistant

Flame-proof Type Circuit Breaker Box SFCB – C 6529 -225AF or 400AF, 255A Max

Explosion-proof 

Rain-tight 

Water-tight

Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D 

NEMA 4, 4X 

II 2G Ex d II C IP 65 

Specification of Circuit Breaker Boxes

1

2

3

4

5

6

7

8

MODEL NO.

CERTIFICATED

MAX CURRENT

IP GRADE

TEMPERATURE

HUMIDITY

ALTITUDE

BASIC FINISH

KOSHA (Korea Occupational Safety & Health Agency)

IP 65

-20

~ 40

95%

1000 m

Spray(Color : Munsel No. 7.5BG 6/1.5)

SFCB 4030

100A

255A

SFCB 5040

SFCB – C 6529

No.

Ex d II C T6  type 

Ex d II B+H2 T6  type

Specification

Circuit Breaker Boxes

Enclosures / Controls / Panels

SFCB Series

SFCB-C 6529 Series

catalog_eng-html.html
background image

B

Circuit Breaker Boxes

Enclosures / Controls / Panels

SFCB 4030 Series - Ex d II B+H2 T6 

Circuit Breaker 

Box

60AF or 100AF, 

100A Max

Flexible Foot 

Installation

Applications

SFCB 4030 hinged cover circuit breaker box used : 

For general motor control and circuit protection witho ut the need for a protective shelter. 

to provide the necessary push-buttons, pilot lights, selector switches and tumbler switches  

For Zone 1 & 2, Flame Proof type (Ex d II B T6+ H2)

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations 

Where exposure to frequent or heavy rain, water, spray, moisture, and humidity is common ; 
such as : offshore drilling facilities, cooling towers, coal preparation  and handling facilities 
and sewage and waste water treatment plant. In areas which are hazardous due to the 
presence of hydrogen or gases and vapors of equivalent hazard such as found in process 
industries, gas manufacturing plants.

Features

Rugged, corrosion resistant, cast cooper-free aluminum construction. (Less than 0.4 of 1%)  

Special Silicon cover gasket provides a water seal tomeet IP65 requirements, and provides superior protection for 

enclosed equipment against water/corrosion.   

Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are broken.

Optional stainless steel hinges provide convenient and easy access for inspection, maintenance 

and systems changes

Standard Finishes

Natural or Epoxy painted (Munsell No. 7.5BG 6/1.5)

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Gasket - Silicon or Rubber 

Hinges - Stainless Steel

Middle plate - Bakelite plate

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500

NEMA 4, 4X / IEC 60529

Technical Data

Current  Range : Max 100A 

Model Number Logic

Series Constant

SFCB 4030

Frame Selections

06F : 60AF
10F : 100AF 

000

Poles 

2P : 2 Poles 
3P : 3 Poles 
4P : 4 Poles

00

Current Rating

5A : 5 Amp 
10A : 10 Amp
15A : 15 Amp

000

20A :  20 Amp
30A :  30 Amp 
40A :  40 Amp 
50A :  50 Amp 

60A :  60 Amp 
75A :   75 Amp 
100A : 100 Amp

Example 1) Ex d II B+H2 Circuit Breaker Box 277Vac 75 Ampere 100AF 3 Poles

SFCB 4030 10AF3P75A 

Example 2) Ex d II B+H2 Circuit Breaker Box 480Vac 60 Ampere 60AF 2 Poles

SFCB 4030 06AF2P60A

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups B, C, D
NEMA 4, 4X 
II 2G Ex d II B+H2 IP 65 

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency) 

catalog_eng-html.html
background image

Enclosures / Controls / Panels

B20 _ B21

Enclosures

/

Controls

/Panels

B

60AF

100AF

100AF

600Vac or

250Vdc

600Vac or

250Vdc

600Vac or

250Vdc

2

3

4

2

3

4

600Vac 

600Vac or

250Vdc

3

60 Amp

60 Amp

60 Amp

5 Amp

10 Amp

15 Amp

20 Amp

30 Amp

40 Amp

50 Amp

60 Amp

75 Amp

100 Amp

5 Amp

10 Amp

15 Amp

20 Amp

BODY

COVER

MOUNT PLATE

BODY BOLT

FLAT WASHER

Spring Washer

MCCB Operating Handle

MCCB

NAME PLATE

Warning Sticker

Caution Sticker

CERTI. Sticker

BOLT

Fix Plate

1

2

3

4

5

6

7

8

9

10

11

12

13

14

AC4C

AC4C

SPCC

STS304

STS304

STS304

-

-

STS304

Art Paper

STS304

Ø15XØ8.5X1.6t

M8

LS E-35S

M8XP 1.25 X15L

10F3P30A

10F3P40A

10F3P50A

10F3P60A

10F3P75A

10F3P100A

10F4P05A

10F4P10A

10F4P15A

10F4P20A

10F4P30A

10F4P40A

10F4P50A

10F4P60A

10F4P75A

10F4P100A

30 Amp

40 Amp

50 Amp

60 Amp

75 Amp

100 Amp

5 Amp

10 Amp

15 Amp

20 Amp

30 Amp

40 Amp

50 Amp

60 Amp

75 Amp

100 Amp

CAT.NO.

CIRCUIT

BREAKER

FRAME SIZE

POLES

VOLTAGE

RATING

CURRENT

RATING

CAT.NO.

CIRCUIT

BREAKER

FRAME SIZE

POLES

VOLTAGE

RATING

CURRENT

RATING

NO.

PART NAME

MATERIALS

REMARKS

Fix Plate

Fix Screw

Terminal Lug

Main MCCB Switch Bushing

Main MCCB Switch Shaft

Main MCCB Switch Linker

Switch Handle

Handle Bushing

O-Ring

O-Ring

Terminal Block

Set Screw

O-Ring

ON/OFF Name plate

15

16

17

18

19

20

21

22

23

24

25

26

27

28

BAKELITE

STS304

Copper

C3604BE-F

C3604BE-F

AI6061

ALDC12

SS400

Silicons

Silicons

-

STS304

Silicons

STS304

430X330

4SQ

(B-CLN-C-M10)

(B-CLN-C-M10)

AN-125

AN-113

M4 X5L

Ø5X1.488L

NO.

PART NAME

MATERIALS

REMARKS

Dimensions 

Circuit Breakers 

06F2P60A

06F3P60A

06F4P60A

10F2P05A

10F2P10A

10F2P15A

10F2P20A

10F2P30A

10F2P40A

10F2P50A

10F2P60A

10F2P75A

10F2P100A

10F3P05A

10F3P10A

10F3P15A

10F3P20A

600Vac 

catalog_eng-html.html
background image

B

Circuit Breaker Boxes

Enclosures / Controls / Panels

SFCB 5040 Series - Ex d II B+H2 T6   

Circuit Breaker 

Box

225AF or 400AF, 
255A Max 

Flexible Foot 

Installation

Applications

SFCB 5040 hinged cover circuit breaker box used : 

For general motor control and circuit protection witho ut the need for a protective shelter. 

to provide the necessary push-buttons, pilot lights, selector switches and tumbler switches  

For Zone 1 & 2, Flame Proof type (Ex d II B T6+ H2)

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations 

Where exposure to frequent or heavy rain, water, spray, moisture, and humidity is common ; 
such as : offshore drilling facilities, cooling towers, coal preparation  and handling facilities 
and sewage and waste water treatment plant. In areas which are hazardous due to the 
presence of hydrogen or gases and vapors of equivalent hazard such as found in process 
industries, gas manufacturing plants.

Features

Rugged, corrosion resistant, cast cooper-free aluminum construction. (Less than 0.4 of 1%)  

Special Silicon cover gasket provides a water seal to meet IP65 requirements, and provides superior protection 

for enclosed equipment against water/corrosion.   

Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are broken.

Optional stainless steel hinges provide convenient and easy access for inspection, maintenance 

and systems changes

Standard Finishes

Natural or Epoxy painted (Munsell No. 7.5BG 6/1.5)

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Gasket - Silicon or Rubber 

Hinges - Stainless Steel

Middle plate - Bakelite plate

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency) 

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500 / NEMA 4, 4X / IEC 60529

Technical Data

Current  Range : Max 255A

Model Number Logic

Series Constant

SFCB 5040

Frame Selections

22F : 225AF
40F : 400AF 

000

Poles 

2P : 2 Poles 
3P : 3 Poles 
4P : 4 Poles

00

Current Rating

100A : 100 Amp
125A : 125 Amp
150A : 150 Amp

0000

175A : 175 Amp
200A : 200 Amp
225A : 225 Amp
250A : 250 Amp

Example 1) Ex d II B+H2 Circuit Breaker Box 277Vac 200 Ampere 225AF 3 Poles

SFCB 5040 22AF3P200A 

Example 2) Ex d II B+H2 Circuit Breaker Box 480Vac 150 Ampere 225AF 2 Poles

SFCB 5040 22AF2P150A

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups B, C, D
NEMA 4, 4X 
II 2G Ex d II B+H2 IP 65 

catalog_eng-html.html
background image

Enclosures / Controls / Panels

B22 _ B23

Enclosures

/

Controls

/Panels

B

Dimensions 

Circuit Breakers 

22F2P100A

22F2P125A

22F2P150A

22F2P175A

22F2P200A

22F2P225A

22F3P100A

22F3P125A

225AF

225AF

600Vac or

250Vdc

600Vac or

250Vdc

2

2

3

4

600Vac or

250Vdc

600Vac or

250Vdc

400AF

400AF

250A

250A

600Vac or

250Vdc

600Vac or

250Vdc

100 Amp

125 Amp

150 Amp

175 Amp

200 Amp

225 Amp

100 Amp

125 Amp

BODY

COVER

MOUNT PLATE

BODY BOLT

FLAT WASHER

Spring Washer

MCCB Operating Handle

MCCB

NAME PLATE

Warning Sticker

Caution Sticker

CERTI. Sticker

GROUNDING Sticker

BOLT

1

2

3

4

5

6

7

8

9

10

11

12

13

14

AC4C

AC4C

SPCC

STS304

STS304

STS304

-

-

STS304

Art Paper

-

-

-

STS304

-

-

-

-

Ø15XØ8.5X1.6t

M8

LS E-35S

-

-

-

-

-

-

M8XP 1.25 X15L

22F3P200A

22F3P225A

22F4P100A

22F4P125A

22F4P150A

22F4P175A

22F4P200A

22F4P225A

200 Amp

225 Amp

100 Amp

125 Amp

150 Amp

175 Amp

200 Amp

225 Amp

CAT.NO.

CIRCUIT

BREAKER

FRAME SIZE

POLES

VOLTAGE

RATING

CURRENT

RATING

CAT.NO.

CIRCUIT

BREAKER

FRAME SIZE

POLES

VOLTAGE

RATING

CURRENT

RATING

NO.

PART NAME

MATERIALS

REMARKS

Fix Plate

Fix Screw

Terminal Lug

Main MCCB Switch Bushing

Main MCCB Switch Shaft

Main MCCB Switch Linker

Switch Handle

Handle Bushing

O-Ring

O-Ring

Terminal Block

Set Screw

O-Ring

ON/OFF Name plate

15

16

17

18

19

20

21

22

23

24

25

26

27

28

BAKELITE

STS304

Copper

C3604BE-F

C3604BE-F

AI6061

ALDC12

SS400

Silicons

Silicons

-

STS304

Silicons

STS304

430 X330

4SQ

-

-

-

-

(B-CLN-C-M10)

(B-CLN-C-M10)

AN-125

AN-113

-

M4 X5L

Ø5X1.488L

NO.

PART NAME

MATERIALS

REMARKS

2

3

175 Amp

22F3P175A

150 Amp

22F3P150A

40F2P250A

40F3P250A

catalog_eng-html.html
background image

B

Circuit Breaker Boxes

Enclosures / Controls / Panels

SFCB-C 6529 Series - Ex d II C T6

Circuit Breaker 

Box

225AF or 400AF, 
255A Max 

Applications

SFCB-C 6529 hinged cover circuit breaker box used : 

For general motor control and circuit protection without the need for a protective shelter. 

to provide the necessary push buttons, pilot lights, selector switches and tumbler switches  

For Zone 1 & 2, Flame Proof type (Ex d II C T6)

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations 

Where exposure to frequent or heavy rain, water, spray, moisture, and humidity is common ; 
such as : offshore drilling facilities, cooling towers, coal preparation  and handling facilities 
and sewage and waste water treatment plant. In areas which are hazardous due to the 
presence of hydrogen or gases and vapors of equivalent hazard such as found in process 
industries, gas manufacturing plants.

In areas which are hazardous due to the presence of hydrogen or gases and vapors of equivalent 
hazard such as found in process industries, gas manufacturing plants. 

Features

Rugged, corrosion resistant, cast cooper-free aluminum construction. (Less than 0.4 of 1%)  

Special Silicon cover gasket provides a water seal to meet IP65 requirements, and provides superior protection 

for enclosed equipment against water/corrosion.   

Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are broken.

Optional stainless steel hinges provide convenient and easy access for inspection, maintenance 

and systems changes

Standard Finishes

Natural or Epoxy painted (Munsell No. 7.5BG 6/1.5)

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Gasket-Silicon or Rubber 

Middle plate-Bakelite plate

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency) 

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500 / NEMA 4, 4X / IEC 60529

Technical Data

Current  Range : Max 255A

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D
NEMA 4, 4X
II 2G Ex d II C IP 65

Model Number Logic

Series Constant

SFCB-C 6529

Frame Selections

22F : 225AF
40F : 400AF 

000

Poles 

2P : 2 Poles 
3P : 3 Poles 
4P : 4 Poles

00

Current Rating

100A : 100 Amp
125A : 125 Amp
150A : 150 Amp

0000

175A : 175 Amp
200A : 200 Amp
225A : 225 Amp
250A : 250 Amp

Example 1) Ex d II B+H2 Circuit Breaker Box 277Vac 200 Ampere 225AF 3 Poles

SFCB-C 6529 22AF3P200A 

Example 2) Ex d II B+H2 Circuit Breaker Box 480Vac 150 Ampere 225AF 2 Poles

SFCB-C 6529 22AF2P150A

catalog_eng-html.html
background image

Enclosures / Controls / Panels

B24 _ B25

Enclosures

/

Controls

/Panels

B

Dimensions 

Circuit Breakers 

22F2P100A

22F2P125A

22F2P150A

22F2P175A

22F2P200A

22F2P225A

22F3P100A

22F3P125A

225AF

225AF

600Vac or

250Vdc

600Vac or

250Vdc

2

3

3

4

600Vac or

250Vdc

600Vac or

250Vdc

400AF

400AF

250A

250A

600Vac or

250Vdc

600Vac or

250Vdc

100 Amp

125 Amp

150 Amp

175 Amp

200 Amp

225 Amp

100 Amp

125 Amp

Circuit Breaker Box Body

Fix Plate

Fix Screw

MCCB

MCCB Operating Handle

Main MCCB Switch Linker

Main MCCB Switch Handle

Terminal Block

Fix Bolt

1

2

3

4

5

6

8

9

10

AC3A

Bakelike

STS304

-

-

AI6061

ADC12

-

STS304

-

240X240

Th M5X12L

-

-

-

(B-CLN-C-M10)

-

M5X30L

22F3P200A

22F3P225A

22F4P100A

22F4P125A

22F4P150A

22F4P175A

22F4P200A

22F4P225A

200 Amp

225 Amp

100 Amp

125 Amp

150 Amp

175 Amp

200 Amp

225 Amp

CAT.NO.

CIRCUIT

BREAKER

FRAME SIZE

POLES

VOLTAGE

RATING

CURRENT

RATING

CAT.NO.

CIRCUIT

BREAKER

FRAME SIZE

POLES

VOLTAGE

RATING

CURRENT

RATING

NO.

PART NAME

MATERIALS

REMARKS

2

3

175 Amp

22F3P175A

150 Amp

22F3P150A

40F2P250A

40F3P250A

Circuit Breaker Box
Cover Ass’y

7

-

-

-

-

C Panel board Cover

Mount Plate

Bolt

Name Plate

Warning Sucker

Ceri, Sucker

Grounding Sucker

ON/OFF Name plate

Terminal Lug

11

12

13

14

15

16

18

19

20

AC3A

SPCC

STS304

STS304

Art Paper

-

STS304

Copper

-

-

-

-

-

-

-

-

4SQ

NO.

PART NAME

MATERIALS

REMARKS

Caution Sucker

17

catalog_eng-html.html
background image

B

Circuit Breaker Boxes

Enclosures / Controls / Panels

Minimum Centers for Drilled and Tapped Openings and Hubs

#16/M16

#22/M20

#28/M25

#36/M32

#42/M40

#54/M50

#70/M63

#82/M75

#104/M90

39

44

47.5

56.5

62.5

71

80.5

87

103.5

49

52.5

61.5

67.5

76

85.5

92

108.5

56

65

71

79.5

89

95.5

112

72

78

86.5

96

102.5

119

84

92.5

102

108.5

125

99

108.5

115

131.5

118

124.5

141

129

145.5

162

#16/M16

#22/M20

#28/M25

#36/M32

#42/M40

#54/M50

#70/M63

#82/M75

#104/M90

Maximum Quantity for Drilled and Tapped Openings

SFCB-C

6529

A or C

B or D

120

49

69

30

50

23

28

14

26

9

17

7

9

3

7

3

5

2

NPT or PF

Model No.

#16

#22

#28

#36

#42

#54

#70

#82

#104

Metric thread

M16

M22

M25

M32

M40

M50

M63

M75

M90

Hub Design

Drilled and tapped conduit openings will be 

evenly spaced and located in the area indicated 
on the location chart. Critical conduit opening 

locations may be indicated by supplying a 

diagram similar to the one shown at below 

indicating critical dimensions and locations.

Specific conduit openings must be located 

dimensionally from box centerlines to conduit 

centerlines and from outside back surface of box 
to conduit centerline.

SFCB-C 6529 Series - Ex d II C T6

Circuit Breaker 

Box

225AF or 400AF, 
255A Max 

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D
NEMA 4, 4X
II 2G Ex d II C IP 65

Drawing indicates position as looking into Hub opening of box

catalog_eng-html.html
background image

Enclosures

/

Controls

/Panels

B

Enclosures / Controls / Panels

B26 _ B27

Flame-proof Type Controls  
SEPB Series Combination Operating Switches – Ex d II C T6 
SETS Series General Use Snap Switches–Ex d II B T6
SEC Series Control Stations–Ex d II B T6 
SECB Series Custom-built Indicator & Control Boxes– Ex d II B+H2 T6 

Flame-proof Type Combination Operating Switches – SEPB Series 1 Gang ~ 3 Gangs

Cl. I, Div. 1 & 2, Groups A, B, C, D

NEMA 4, 4X 

II 2G Ex d II C IP 65

Explosion-proof 

Rain-tight / Water-tight

Corrosion Resistant

Flame-proof Type General Use Snap Switches – SETS Series 1 Gang ~ 3 Gangs 

Cl. I, Div. 1 & 2, Groups C, D 

NEMA 4, 4X 

II 2G Ex d II B IP 65

Explosion-proof 

Rain-tight / Water-tight

Corrosion Resistant

Flame-proof Type Control Stations – SEC Series 1 Device ~5 Devices With UE 
Control Devices Series

Cl. I, Div. 1 & 2, Groups C, D 

NEMA 4, 4X 

II 2G Ex d II B IP 65

Explosion-proof 

Rain-tight / Water-tight

Corrosion Resistant

Flame-proof Type Custom-built Indicator & Control Boxes - SECB Series
With ELC Lens Covers Series With UE Control Devices Series

Cl. I, Div. 1 & 2, Groups B, C, D 

NEMA 4, 4X 

II 2G Ex d II B+H2 IP 65

Explosion-proof 

Rain-tight / Water-tight

Corrosion Resistant

Controls

Enclosures / Controls / Panels

SEPB Series

SETS Series

SEC Series

SECB Series

catalog_eng-html.html
background image

B

Controls

Enclosures / Controls / Panels

SEPB Series Combination Operating 
Switches – Ex d II C T6  

Copper Free 
Aluminum

1 Gang ~ 3 Gangs

Applications

SEPB Series Combination operating switches are used  for operating instruments & equipment, 
in hazardous area. 

For use indoors or outdoors, in areas which are hazardous due to the presence of 

flammable gases and vapors. 

For installation in petroleum refineries, chemical, petrochemical, and other industrial 

process facilities; grain processing and storage facilities; and other heavy industrial 
applications where Class I hazards are present. 

Features

Mounting type - Surface mounting. 

1 Gang ~ 3 Gang.

Bodies, with extra room for wire pulling and termination. 

Bodies have 1/2", 3/4“ dead-end or through-feed conduit hubs with integral bushing for protection of wire insulation. 

Covers and bodies are available in copper-free aluminum for light weight and corrosion resistance.

Legend plates have large lettering to give clear indication of device function. 

Special Silicon or Neoprene cover 0-ring gasket provides a water seal to meet IP65 requirements, 

and provides superior protection for enclosed equipment against water/corrosion. 

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Gasket-Silicon or Rubber 

Certification

Certified KOGAS (Korea Gas Safety Corporation).

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

NEC 500

NEMA 4, 4X

IEC 60529

Options

Extra room for wire pulling and termination. 

Standard Finishes

Epoxy painted (Munsell No. 7.5BG 6/1.5).

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D
NEMA 4, 4X
Zone 1, Zone 2
II 2G Ex d II C IP65

1 Gang

2 Gang

3 Gang

catalog_eng-html.html
background image

Enclosures

/

Controls

/Panels

B

Enclosures / Controls / Panels

B28 _ B29

Selection Table  

Push Button

Selector Switch

Pilot Light

PB & SW & PL

PB & PL & PL

SW & PL & PL

1 gang

Push Button &
Selector Switch

Push Button &
Pilot Light

Selector Switch
& Pilot Light

3 gangs 

2 gangs 

SEPB 1G PB DE 16

SEPB 1G SW DE 16

SEPB 1G PL DE 16

SEPB 3G PB SW PL DE 16

SEPB 3G PB PL PL DE 16

SEPB 3G SW PL PL DE 16

GANGS

SWITCH

CONSTRUCTION

SEPB 2G PB SW DE 16

SEPB 2G PB PL DE 16

SEPB 2G SW PL DE 16

SEPB 1G PB DE 22

SEPB 1G SW DE 22

SEPB 1G PL DE 22

SEPB 3G PB SW PL DE 22

SEPB 3G PB PL PL DE 22

SEPB 3G SW PL PL DE 22

SEPB 2G PB SW DE 22

SEPB 2G PB PL DE 22

SEPB 2G SW PL DE 22

SEPB 1G PB FT 16

SEPB 1G SW FT 16

SEPB 1G PL FT 16

SEPB 3G PB SW PL FT 16

SEPB 3G PB PL PL FT 16

SEPB 3G SW PL PL FT 16

SEPB 2G PB SW FT 16

SEPB 2G PB PL FT 16

SEPB 2G SW PL FT 16

SEPB 1G PB FT 22

SEPB 1G SW FT 22

SEPB 1G PL FT 22

SEPB 3G PB SW PL FT 22

SEPB 3G PB PL PL FT 22

SEPB 3G SW PL PL FT 22

SEPB 2G PB SW FT 22

SEPB 2G PB PL FT 22

SEPB 2G SW PL FT 22

CAT.NO.

DEAD END

1/2”

3/4”

1/2”

3/4”

FEED THRU.

Model Number Logic

Series
Constant

SEPB

Gang type

1G : 1 gang
2G : 2 gang
3G : 3 gang

00

Switch type

PB : Push button
SW : Selector S/W
PL : Pilot light

00

Hub type

DE : Dead end
FT : Feed Thru.

00

Hub 
Threads type

P : BSPP threads
N : NPT threads

0

00

Example 1) Combination operating switches 1 gang Push button, NPT 1/2” 2 Hub  SEPB 1G PB FT N16 
Example 2) Combination operating switches 3 gang Push button & Selector & Pilot light, PF 3/4” 1 Hub SEPB 3G PB SW PL  DE P22 

Hub threads

16 : 1/2”
22 : 3/4””

catalog_eng-html.html
background image

B

Controls

Enclosures / Controls / Panels

SETS Series General Use 
Snap Switches – Ex d II B T6  

Tumbler Switches 

Copper Free 
Aluminum

1 Gang ~ 3 Gangs

Applications

SETS Series Combination circuit operating switches are used for operating 1Ø motors, 
1Ø pumps, lighting fixtures, etc

For use indoors or outdoors, in areas which are hazardous due to the presence of 

flammable gases and vapors. 

For installation in petroleum refineries, chemical, petrochemical, and other industrial 

process facilities; grain processing and storage facilities; and other heavy industrial 
applications where Class I hazards are present. 

Features

Mounting type - Surface mounting. 

1 Gang ~ 3 Gang.

Bodies, with extra room for wire pulling and termination. 

Bodies have 1/2", 3/4“ dead-end or through-feed conduit hubs with integral bushing for protection of wire insulation. 

Covers and bodies are available in copper-free  aluminum for light weight and corrosion resistance.

Legend plates have large lettering to give clear indication of device function. 

Special Silicon or Neoprene cover 0-ring gasket provides a water seal to meet IP65 requirements, 

and provides superior protection for enclosed equipment against water/corrosion. 

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Gasket-Silicon or Rubber 

Compliances

Certified KOGAS (Korea Gas Safety Corporation).

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

NEC 500

NEMA 4, 4X

IEC 60529

Options

Extra room for wire pulling and termination. 

Standard Finishes

Epoxy painted (Munsell No. 7.5BG 6/1.5).

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups C, D
NEMA 4, 4X
Zone 1, Zone 2
II 2G Ex d II B IP65

1 Gang

2 Gang

3 Gang

Model Number Logic

Series
Constant

SETS

Gang type

1G : 1 gang
2G : 2 gang
3G : 3 gang

00

Poles

1G : 1 pole
2G : 2 poles 
3G : 3 poles 

00

Hub type

DE : Dead End
FT : Feed Thru.

00

Rating 
current 

10A
20A

000

Hub 
Threads type

P : BSPP threads
N : NPT threads

0

Example 1) General use snap switches 1 gang, NPT 1/2” 2 hub, 2Poles 10A SETS 1G 10A 2P FT N16 
Example 2) General use snap switches 3 gang, PF 3/4” 1 hub, 3Poles 20A SETS 3G 20A 3P DE P22 

00

Hub threads

16 : 1/2”
22 : 3/4””

catalog_eng-html.html
background image

Enclosures / Controls / Panels

B30 _ B31

Enclosures

/

Controls

/Panels

B

Selection Table    

1 gang

3 gangs 

2 gangs 

10A

20A

10A

20A

10A

20A

SETS 1G 10A 1P DE 16

SETS 1G 10A 2P DE 16

SETS 1G 10A 3P DE 16

SETS 1G 20A 1P DE 16

SETS 1G 20A 2P DE 16

SETS 1G 20A 3P DE 16

SETS 2G 10A 1P DE 16

SETS 2G 10A 2P DE 16

SETS 2G 10A 3P DE 16

SETS 2G 20A 1P DE 16

SETS 2G 20A 2P DE 16

SETS 2G 20A 3P DE 16

SETS 3G 10A 1P DE 16

SETS 3G 10A 2P DE 16

SETS 3G 10A 3P DE 16

SETS 3G 20A 1P DE 16

SETS 3G 20A 2P DE 16

SETS 3G 20A 3P DE 16

1 pole 

2 poles

3 poles

1 pole 

2 poles

3 poles

1 pole 

2 poles

3 poles

1 pole 

2 poles

3 poles

1 pole 

2 poles

3 poles

1 pole 

2 poles

3 poles

GANGS

RATING

CURRENT

POLES

SETS 1G 10A 1P DE 22

SETS 1G 10A 2P DE 22

SETS 1G 10A 3P DE 22

SETS 1G 20A 1P DE 22

SETS 1G 20A 2P DE 22

SETS 1G 20A 3P DE 22

SETS 2G 10A 1P DE 22

SETS 2G 10A 2P DE 22

SETS 2G 10A 3P DE 22

SETS 2G 20A 1P DE 22

SETS 2G 20A 2P DE 22

SETS 2G 20A 3P DE 22

SETS 3G 10A 1P DE 22

SETS 3G 10A 2P DE 22

SETS 3G 10A 3P DE 22

SETS 3G 20A 1P DE 22

SETS 3G 20A 2P DE 22

SETS 3G 20A 3P DE 22

SETS 1G 10A 1P FT 16

SETS 1G 10A 2P FT 16

SETS 1G 10A 3P FT 16

SETS 1G 20A 1P FT 16

SETS 1G 20A 2P FT 16

SETS 1G 20A 3P FT 16

SETS 2G 10A 1P FT 16

SETS 2G 10A 2P FT 16

SETS 2G 10A 3P FT 16

SETS 2G 20A 1P FT 16

SETS 2G 20A 2P FT 16

SETS 2G 20A 3P FT 16

SETS 3G 10A 1P FT 16

SETS 3G 10A 2P FT 16

SETS 3G 10A 3P FT 16

SETS 3G 20A 1P FT 16

SETS 3G 20A 2P FT 16

SETS 3G 20A 3P FT 16

SETS 1G 10A 1P FT 22

SETS 1G 10A 2P FT 22

SETS 1G 10A 3P FT 22

SETS 1G 20A 1P FT 22

SETS 1G 20A 2P FT 22

SETS 1G 20A 3P FT 22

SETS 2G 10A 1P FT 22

SETS 2G 10A 2P FT 22

SETS 2G 10A 3P FT 22

SETS 2G 20A 1P FT 22

SETS 2G 20A 2P FT 22

SETS 2G 20A 3P FT 22

SETS 3G 10A 1P FT 22

SETS 3G 10A 2P FT 22

SETS 3G 10A 3P FT 22

SETS 3G 20A 1P FT 22

SETS 3G 20A 2P FT 22

SETS 3G 20A 3P FT 22

CAT.NO.

DEAD END

1/2”

3/4”

1/2”

3/4”

FEED THRU.

Dimensions

SETS 1 Gang – Mounting hole 2-Ø7.0

SETS 2 Gang – Mounting hole 4-Ø10.0

SETS 3 Gang – Mounting hole 4-Ø10.0 

catalog_eng-html.html
background image

B

Controls

Enclosures / Controls / Panels

SEC Series Control Stations – Ex d II B T6

Copper Free 
Aluminum

1 Device ~ 3 Device

Applications

Five modular components – operators, terminal blocks, covers, legend plates, 
and bodies – are combined to provide a variety of control stations which are:

For use indoors or outdoors, in areas which are hazardous due to the presence of 

flammable gases and vapors, or combustible dust. 

Used in conjunction with magnetic starters or contactors for remote control of motors and 

other electrical apparatus. 

For installation in petroleum refineries, chemical, petrochemical, and other industrial 

process facilities; grain processing and storage facilities; and other heavy industrial 
applications where Class I hazards are present. 

In areas which are hazardous due to the presence of gases and vapors of equivalent 

hazard such as found in process industries and gas manufacturing plants.

Features

Two mounting type - Surface mounting, Stanchion mounting

Each covers for 1 ~ 5 devices respectively per station.

Bodies, with extra room for wire pulling and termination, also include two integral mounting feet for fast, 

secure installation.

Bodies have 1/2", 3/4", 1”, 1-1/4”or 1-1/2" dead-end or through-feed conduit hubs with integral bushing for 

protection of wire insulation.  

Covers and bodies are available in copper-free aluminum for light weight and corrosion resistance.

Legend plates have large lettering to give clear indication of device function. 

Space is available for field markings.

Special Silicon or Neoprene cover 0-ring gasket provides a water seal to meet IP65 requirements, 

and provides superior protection for enclosed equipment against water/corrosion. 

Ground joint cover opening provides maximum opening for pulling wires or mounting devices.

Standard Materials

Copper-free Aluminum

Accessory - Stainless Steel

Gasket - Silicon or Rubber

Sunshade - Stainless Steel  

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500

NEMA 4, 4X

IEC 60529

Options

Diagram Pocket 

Extra room for wire pulling and termination. 

Standard Finishes

Epoxy painted (Munsell No. 7.5BG 6/1.5).

Stanchion Mounting

Wall Mounting 

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups C, D
NEMA 4, 4X
Zone 1, Zone 2
II 2G Ex d II B IP65

catalog_eng-html.html
background image

Enclosures

/

Controls

/Panels

B

Enclosures / Controls / Panels

B32 _ B33

Model Number Logic

Series
Constant

SEC

Mounting type

W : Wall mounting 
S  : Stanchion 

mounting

0

Hub 
Threads type

P : BSPP 

threads

N : NPT threads

0

Hub type

DE : Dead end
FT : Feed Thru.

00

No. 
of Device 

1 ~ 5

0

Hub threads

16 : 1/2”
22 : 3/4”
28 : 1”
36 : 1-1/4” 
42 : 1-1/2” 

0

Example 1) Control Station 4 devices, #42 Stanchion mounting, with TB and Sunshade  SEC S 4 DE P42 TB SH 
Example 2) Control Station 3 devices, NPT #28 2 hub, Surface or Wall mounting SEC W 3 FT N28 

Dimensions

SEC 1

SEC 2

SEC 3

SEC 4

SEC 5

100

100

100

100

100

275

315

355

395

435

100

115

115

115

130

120

120

120

135

140

100

115

115

115

130

140

180

220

260

300

120

120

120

135

140

115

190

190

210

250

115

115

170

210

250

10

10

10

10

10

100

100

100

100

100

10

10

10

10

10

18

18

18

18

18

250

250

250

250

250

CAT. NO.

WIDTH HEIGHT DEPTH

DIMENSIONS WITH TERMINAL BOX (MM)

DIMENSIONS WITHOUT TERMINAL BOX (MM)

STANCHION MOUNTING

DIMENSIONS (MM)

MOUNTING 

HOLE CENTER MOUNTING 

HOLE 

MOUNTING 

HOLE 

MOUNTING 

HOLE 

MOUNTING 

HOLE

CENTER 

X

Y

00

Options

TB : With 

Terminal Box 

SH : With 

Sunshade

WIDTH HEIGHT DEPTH

MOUNTING 

HOLE CENTER

X

Y

Installation

Wall Mounting

Stanchion Mounting

Stanchion Mounting Base

Wall Mounting with Terminal Box 

catalog_eng-html.html
background image

B

Controls

Enclosures / Controls / Panels

SECB Series Custom-built indicator &
Control Boxes – Ex d II B+H2 T6

Explosion-proof 
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups B, C, D
NEMA 4, 4X 
Zone 1, Zone 2 
II 2G Ex d II B+H2 IP65

Copper Free 
Aluminum

With ELC Lens      
Covers Series

With UE Control      
Devices Series

Flexible Foot      
Installation

Applications

SECB custom-built control panels are used with ELC Lens covers series & UE Control devices series

as a means of grouping control stations for centralized process control in 

hazardous areas in minimum space. 

Manufactured for hazardous environments, the SECB Custom-Built Indicate & 

Control Boxes are an explosion-proof enclosure built to customer specific requirements. 

Available in a variety of sizes with an unlimited combination of devices, 

windows, and markings, these boxes are designed to maximize the efficiency of each unique process.

For Zone 1 & 2, Flame Proof type (Ex d II B T6+ H2)

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations. 

Features

To reduce installation costs, SECB series can be supplied with control components factory wired to terminal 

blocks mounted in the box. Relays and other control devices can also be mounted in the boxes for special 
control functions.  

Surface mounted control boxes have the components assembled in the hinged cover, readily accessible 

for circuit checking and trouble shooting.

Flat cover provides additional space for mounting a greater number of control devices.

Special Silicon cover gasket provides a water seal to meet IP65 requirements, and provides superior protection 

for enclosed equipment against water/corrosion.   

Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are broken.

ELC Lens covers can be factory installed to enable viewing of digital read out meters and devices such as    

Volt meters, Flow meters, Gas analyzers, Process receivers, Transmitters and Controllers

The foundation of the Custom-Built Control Boxes are our tried and tested copper-free aluminum EJB 

enclosure. This corrosion resistant, heavy-duty enclosure features bolted construction, stainless steel 
hinges, and flexible tap-in mounting feet.

Standard Finishes

Natural or Epoxy painted (Munsell No. 7.5BG 6/1.5)

Standard Materials

Copper-free Aluminum

Accessory-Stainless Steel

Gasket – Silicon or Rubber 

Sunshade - Stainless Steel

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500 / NEMA 4, 4X / IEC 60529

Options

Diagram Pocket

Ingress Protection : IP 65

Cover Open : Handle, Hinge 

Cover Fix Bolt : Spring Return Type

catalog_eng-html.html
background image

Enclosures

/

Controls

/Panels

B

Enclosures / Controls / Panels

B34 _ B35

SECB 4030A

SECB 4030B

SECB 5040A

SECB 5040B

SECB 5050A

SECB 5050B

SECB 5050C

SECB 6060A

SECB 6060B

SECB 6060C

SECB 7060A

SECB 7060B

SECB 7060C

6

12

12

20

15

15

25

24

24

36

30

30

42

1 - ELC 92  

-

1 - ELC 92

-

1 - ELC 92

2 - ELC 92

-

1 - ELC 92

2 - ELC 92

-

1 - ELC 92

2 - ELC 92

-

400

UE CONTROL DEVICES (EA)

ELC LENS COVER SPEC.

CAT.NO.

DIMENSIONS (MM)

WIDTH

HEIGHT

Selection Table 

Dimensions

500

500

600

700

300

400

500

600

600

SW-001141

SW-001147

SW-000645

SW-000638

SW-000639

SW-000640
SW-000641
SW-000642
SW-000643
SW-000782
SW-000783

SW-001628

1

2

3

4

5
6

7
8
9

10
11
12
13
14
15
16
17
18
19

BODY

COVER

MOUNT PLATE

BODY BOLT (EJB-4030)
P. WASHER
BOLT SPRING  (EJB-4030)

HANDLE
HINGE ASSEMBLY
NAME PLATE
Warming Sticker
Caution Sticker
Certification Sticker
Earth Sticker

HEX HEAD BOLT

FIX PLATE

BOLT

TERMINAL LUG

BOLT

Teminal Block

NO.

1

1

4

14

14
14

1
2
1
1
1
1
2

16

1
8
2
2
1

Q’TY

DWC No.

REMARKS

AC3A (AI Alloy)

AC3A (AI Alloy)

SPCC

SUS304

SUS304
SUS

SUS304
SUS304
SUS304
Art Paper
Dacron
Dacron
Dacron
SUS
BAKELITE
SUS
Cu
SUS
PA66

MATERIALS

PART NAME

catalog_eng-html.html
background image

B

Controls

Enclosures / Controls / Panels

SECB Series Custom-built Indicator &
Control Boxes – Ex d II B+H2 T6

Copper Free 
Aluminum

With ELC Lens      
Covers Series

With UE Control      
Devices Series

Flexible Foot      
Installation

SECB 4030

SECB 5040

SECB 5050

SECB 6060

SECB 7060

400

500

500

600

700

300

400

500

600

600

225

235

235

235

235

190

200

200

200

200

330

415

415

515

615

337~351

437~451

537~551

637~651

637~651

CAT.NO.

DIMENSIONS (MM)

A

B

C

D

E

F

Dimensions

Exterior View

Internal and external
ground terminations
simplify grounding
requirements 

Explosion-proof 
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups B, C, D
NEMA 4, 4X 
Zone 1, Zone 2 
II 2G Ex d II B+H2 IP65

Optional ELC Lens covers explosion-proof glass window is available when you need to see inside

Optional cover Fix Bolt : Spring Return Type 

Optional individual device markings to clearly  indicate the function of each device.May be added in the  field

Silicon or rubber cover gasket – b etween body and cover - provides NEMA 4, 4X, IP65 watertight seal

Universal Drains EPD 16 or UAB 16

Detachable mounting feet offer a simple and secure way to mount enclosure,and are replaceable if broken or lost 

Copper-free aluminum construction available with epoxy powder coat for additional protection in corrosive atmospheres

catalog_eng-html.html
background image

Enclosures / Controls / Panels

B36 _ B37

Enclosures

/

Controls

/Panels

B

Flame-proof Type Electrical Products 
SLS Series Micro & Limit Switches–Ex d II B T6 / SEPR Series Receptacles & 
Plugs – Ex d II B+H2* T6 / SDPR Series Receptacles & Plugs– Non-hazardous Area 
ELES Series Exit Sign– Ex d II B T6 / SEPR Series Receptacles & Plugs – Ex d II B+H2* T6   

Flame-proof Type Exit Sign – ELES Series Halogen Lamps /Factory Sealed 
Heat Resistant Glass 220Vac 4W or 8W 

Cl. I, Div. 1 & 2, Groups C, D 

NEMA 4, 4X 

II 2G Ex d II B IP 65

Explosion-proof 

Rain-tight 

Water-tight 

Corrosion Resistant 

Flame-proof Type Micro & Limit Switches – SLS Series Five Type Limit Switches 

Cl. I, Div. 1 & 2, Groups C, D 

NEMA 4, 4X 

II 2G Ex d II B IP 65

Explosion-proof 

Rain-tight / Water-tight

Corrosion Resistant

Explosion-proof 

Rain-tight 

Water-tight 

Corrosion Resistant 

Flame-proof Type Receptacles & Plugs – SEPR Series Four Type (25A, 30A, 60A, 100A) 
1 Gang ~ 3 Gangs (25A only) 

Cl. I, Div. 1 & 2, Groups C, D 

NEMA 4, 4X 

II 2G Ex d II B IP 65

Non-hazardous Area Receptacles &  Plugs –SDPR Series Four Type  (30A, 60A, 75A, 100A) 

Wet locations 

Rain-tight 

Water-tight 

Corrosion Resistant 

Electrical Products

Enclosures / Controls / Panels

catalog_eng-html.html
background image

B

Electrical Products

Enclosures / Controls / Panels

SLS Series Micro & Limit Switches – Ex d II B T6  

Copper Free 
Aluminum

Five Type Limit 

Switches

For use indoors or outdoors, in areas which are hazardous due to the presence of 

flammable gases and vapors. 

Features

Five type limit switches – Roller lever, roller adjust lever, spring lever, roller push, roller 90

°

angle 

lever – provide a variety of limit switches which are :

High mechanical intensity 

Built in 2 circuit double micro switch

Structure of heat, oil/vibration resistance 

Various of lever structure such as roller lever type and  etc

Special Silicon cover gasket provides a water seal to meet IP65 requirements, and provides superior protection 

for enclosed equipment against water/corrosion. 

Diverse conduit selection for wide range of applications

External and internal grounding screw

Standard Materials

Copper-free Aluminum

Accessory – Stainless Steel

Gasket – Silicon or Rubber 

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

Standard Finishes

Epoxy painted (Munsell No. 7.5BG 6/1.5).

Applications

SLS Series Limit switches are used in hazardous area

Roller Lever

Spring Lever

Roller 90

°

Angle Lever

Model Number Logic

Series
Constant

SLS

Mounting type

RL : Roller lever
AL : Roller adjust lever
RP : Roller push
SL : Spring lever
RA : Roller 90

°

angle lever

0

Elec. Spec.

Aac : 6A 110Vac
Bac : 5A 220Vac
Cac : 4A 440Vac
Dac : 3A 500Vac

00

Hub 
Threads type

P : BSPP 

threads

N : NPT threads

0

Example 1) Limit switch roller adjust lever 5A 220Vac NPT 1/2” Hub SLC AL Bac N16 
Example 2) Limit switch spring lever 2A 110Vdc PF 1/2” hub SLC SL Cdc P16

00

Hub threads

16 : 1/2”
22 : 3/4”

Elec. Spec.

Adc : 8A 24Vdc
Bdc : 4A 48Vdc
Cdc : 2A 110Vdc

Ddc : 1A 220Vdc

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups C, D 
NEMA 4, 4X
Zone 1, Zone 2
II 2G Ex d II B IP65

Roller Push

Roller 

Adjust Lever 

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

NEC 500 / NEMA 4, 4X / IEC 60529

catalog_eng-html.html
background image

Enclosures / Controls / Panels

B38 _ B39

Enclosures

/

Controls

/Panels

B

6A 110V

5A 220V

4A 440V

3A 500V

8A 24V

4A 48V

2A 110V

1A 220V

AC

DC

SLS RL Aac

SLS RL Bac

SLS RL Cac

SLS RL Dac

SLS RL Adc

SLS RL Bdc

SLS RL Cdc

SLS RL Ddc

SLS RA Aac

SLS RA Bac

SLS RA Cac

SLS RA Dac

SLS RA Adc

SLS RA Bdc

SLS RA Cdc

SLS RA Ddc

ELEC. SPEC.

CAT. NO.

ROLLER LEVER

SLS AL Aac

SLS AL Bac

SLS AL Cac

SLS AL Dac

SLS AL Adc

SLS AL Bdc

SLS AL Cdc

SLS AL Ddc

ROLLER  ADJUST LEVER

SLS RP Aac

SLS RP Bac

SLS RP Cac

SLS RP Dac

SLS RP Adc

SLS RP Bdc

SLS RP Cdc

SLS RP Ddc

ROLLER PUSH

SLS SL Aac

SLS SL Bac

SLS SL Cac

SLS SL Dac

SLS SL Adc

SLS SL Bdc

SLS SL Cdc

SLS SL Ddc

SPRING LEVER

ROLLER 90

°

ANGLE LE

Selection Table

MOUNTING DIM.

MOUNTING HOLE

ROLLER SIZE

ROLLER MATERIAL

Ø

6.0

Ø

19*6.4t

Stainless steel

DESCRIPTION

DIMENSIONS (MM)

ROLLER LEVER

55*74

Ø

6.0

Stainless steel

Ø

6.5

ROLLER  ADJUST LEVER

Ø

19*6.4t

Ø

19*6.4t

Ø

19*6.4t

ROLLER PUSH

-

-

SPRING LEVER

ROLLER 90

°

ANGLE LE

Technical Data

Dimensions

Roller Lever

Roller Adjust Lever 

Roller Push

Roller 90

°

Angle Lever

Spring Lever

catalog_eng-html.html
background image

B

Electrical Products

Enclosures / Controls / Panels

SEPR Series Receptacles & Plugs – Ex d II B+H2* T6

Copper Free 
Aluminum

Four Type

25A, 30A, 
60A*, 100A

1 Gang ~ 3 Gangs 
(for 25A)

To supply power to portable electrical equipment such as hand lamps,lighting systems, power tools, 
conveyors, welders and similar equipment. 

In areas which are hazardous due to the presence of flammable vapors or gases. 

In damp, wet or corrosive locations. 

Indoors or outdoors at petroleum refineries, chemical and petrochemical plants and facilities for 

processing and handling grain, flour and starch.

Features

Plug cannot be withdrawn under load. 

Cover must not be removed when switch is “ON”

Smallest mounting footprint for interlocks

SEPR for USE with Magnetic 

Motor Starters or Contactors 

SEPR units listed below operate in the same way 

as standard units but are intended only for use 
with magnetic motor starters or contactors  
(see Wiring Diagram 1). 

Receptacles have leads for splicing to conductors 

from the load side of contactor. The switch 
actuated by the plug is wired into the starter or 
contactor coil circuit and controls only this circuit. 
The starter or contactor is energized only when 
the plug is fully inserted and rotated to close the 
switch. Since the plug is inserted or withdrawn 
only when the switch is open, the circuit cannot be 
made or broken under the load

Standard Materials

Copper-free Aluminum

Accessory – Stainless Steel

Gasket – Silicon or Rubber 

Applications

SEPR Series interlock receptacles are used:  

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure- tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500 / NEMA 4, 4X / IEC 60529

Standard Finishes

Epoxy painted (Munsell No. 7.5BG 6/1.5).

Certification

Certified KOSHA

(Korea Occupational Safety & Health Agency)

Wire diagram 1.

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups C, D
NEMA 4, 4X
Zone 1, Zone 2
II 2G Ex d II B IP 65* 

SEPR 25 

SEPR 30

SEPR 60

SEPR 100 

catalog_eng-html.html
background image

Enclosures

/

Controls

/Panels

B

Enclosures / Controls / Panels

B40 _ B41

Model Number Logic

Series
Constant

SEPR

Current 
rating max.

25 : 25A
30 : 30A
60 : 60A
100 : 100A

00

Gangs or 
Pins

1G : 1 gang 
2G : 2 gangs 
3G : 3 gangs
3P : 2P+1E
4P : 3P+1E

00

Rated voltage

22 : 220Vac 
25 : 250Vac(SEPR 25) 
25 : 250Vdc(SEPR 60 or 100) 
46 : 460Vac 

00

Rated 
current 

000

Hub type

DE : Dead end
FT : Feed Thru.

00

Hub 
Threads type

P : BSPP threads
N : NPT threads

0

Example 1) For Hazardous area Receptacle & plug 15A 250Vac 3gangs NPT 1/2” 2 Hub SEPR 25 3G 25 15A FT N16 
Example 2) For Hazardous area Receptacle & plug 30A 460Vac 3P+1E PF 3/4” 1 Hub SEPR 30 4P 46 30A DE P22

00

Hub threads

16 : 1/2”
22 : 3/4”
28 : 1” 

Selection Table 

SEPR 25

1 gang

2 gangs 

3 gang

SEPR 25 1G 25 15A DE 16

SEPR 25 1G 25 20A DE 16

SEPR 25 1G 25 25A DE 16

SEPR 25 2G 25 15A DE 16

SEPR 25 2G 25 20A DE 16

SEPR 25 2G 25 25A DE 16

SEPR 25 3G 25 15A DE 16

SEPR 25 3G 25 20A DE 16

SEPR 25 3G 25 25A DE 16

15A

20A

25A

15A

20A

25A

15A

20A

25A

MODEL GANGS

RATED

CURRENT

SEPR 25 1G 25 15A DE 22

SEPR 25 1G 25 20A DE 22

SEPR 25 1G 25 25A DE 22

SEPR 25 2G 25 15A DE 22

SEPR 25 2G 25 20A DE 22

SEPR 25 2G 25 25A DE 22

SEPR 25 3G 25 15A DE 22

SEPR 25 3G 25 20A DE 22

SEPR 25 3G 25 25A DE 22

SEPR 25 1G 25 15A FT 16

SEPR 25 1G 25 20A FT 16

SEPR 25 1G 25 25A FT 16

SEPR 25 2G 25 15A FT 16

SEPR 25 2G 25 20A FT 16

SEPR 25 2G 25 25A FT 16

SEPR 25 3G 25 15A FT 16

SEPR 25 3G 25 20A FT 16

SEPR 25 3G 25 25A FT 16

SEPR 25 1G 25 15A FT 22

SEPR 25 1G 25 20A FT 22

SEPR 25 1G 25 25A FT 22

SEPR 25 2G 25 15A FT 22

SEPR 25 2G 25 20A FT 22

SEPR 25 2G 25 25A FT 22

SEPR 25 3G 25 15A FT 22

SEPR 25 3G 25 20A FT 22

SEPR 25 3G 25 25A FT 22

CAT.NO.

DEAD END

1/2”

3/4”

1/2”

3/4”

FEED THRU.

PINS

RATED VOLTAGE

RETED INTERRUPTING
CAPACITY

250Vac

220Vac

220Vac

460Vac

220Vac

460Vac

250Vdc

220Vac

460Vac

250Vdc

5KA

-

5KA

2.5KA

20KA

15KA

10KA

20KA

15KA

10KA

DESCRIPTION

CAT. NO.

SEPR 30

2P+1E

SEPR 60

SEPR 25

SEPR 100

Technical Data

SEPR 30

2P+1E

3P+1E

3P+1E

SEPR 30 3P 22 30A DE 22

SEPR 30 4P 22 30A DE 22

SEPR 30 4P 46 30A DE 22

SEPR 60 4P 22 60A DE 22

SEPR 60 4P 46 60A DE 22

SEPR 60 4P 25 60A DE 22

SEPR 100 4P 22 100A DE 22

SEPR 100 4P 46 100A DE 22

SEPR 100 4P 25 100A DE 22

220Vac

220Vac

460Vac

220Vac

460Vac

250Vdc

220Vac

460Vac

250Vdc

MODEL

PINS

RATED

VOLTAGE

SEPR 30 3P 22 30A DE 28

SEPR 30 4P 22 30A DE 28

SEPR 30 4P 46 30A DE 28

SEPR 60 4P 22 60A DE 28

SEPR 60 4P 46 60A DE 28

SEPR 60 4P 25 60A DE 28

SEPR 100 4P 22 100A DE 28

SEPR 100 4P 46 100A DE 28

SEPR 100 4P 25 100A DE 28

SEPR 30 3P 22 30A FT 22

SEPR 30 4P 22 30A FT 22

SEPR 30 4P 46 30A FT 22

SEPR 60 4P 22 60A FT 22

SEPR 60 4P 46 60A FT 22

SEPR 60 4P 25 60A FT 22

SEPR 100 4P 22 100A FT 22

SEPR 100 4P 46 100A FT 22

SEPR 100 4P 25 100A FT 22

SEPR 30 3P 22 30A FT 28

SEPR 30 4P 22 30A FT 28

SEPR 30 4P 46 30A FT 28

SEPR 60 4P 22 60A FT 28

SEPR 60 4P 46 60A FT 28

SEPR 60 4P 25 60A FT 28

SEPR 100 4P 22 100A FT 28

SEPR 100 4P 46 100A FT 28

SEPR 100 4P 25 100A FT 28

CAT.NO.

DEAD END

3/4”

1”

3/4”

1”

FEED THRU.

2P+1E

3P+1E

3P+1E

3P+1E

SEPR 60

SEPR

100

3P+1E

catalog_eng-html.html
background image

B

Electrical Products

Enclosures / Controls / Panels

SEPR Series Receptacles & Plugs – Ex d II B+H2* T6

Copper Free 
Aluminum

Four Type

25A, 30A, 
60A*, 100A

1 Gang ~ 3 Gangs 
(for 25A)

Dimensions

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups C, D
NEMA 4, 4X
Zone 1, Zone 2
II 2G Ex d II B IP 65* 

SEPR 25 1G

SEPR 25 2G

SEPR 25 3G

SEPR 60

SEPR 100

SEPR 30

catalog_eng-html.html
background image

Enclosures / Controls / Panels

B42 _ B43

Enclosures

/

Controls

/Panels

B

SDPR Series Receptacles & Plugs– Non-hazardous Area 

Receptacles & Plugs (Non-hazardous.)

Wet locations 
Rain-tight  
Water-tight 
Corrosion Resistant 

Copper Free 
Aluminum

Four Type

30A, 60A, 

75A, 100A 

To supply power to portable electrical equipment such as hand lamps,lighting systems, power tools, 
conveyors, welders and similar equipment. 

In damp, wet or corrosive locations. 

Indoors or outdoors at petroleum refineries, chemical and petrochemical plants and facilities for 
processing and handling grain, flour and starch.

Features

Plug cannot be withdrawn under load. 

Smallest mounting footprint for interlocks

SDPR for USE with Magnetic 

Motor Starters or Contactors   

SDPR units listed below operate in the same way 

as standard units but are intended only for use 
with magnetic motor starters or contactors 
(see Wiring Diagram 1). 

Receptacles have leads for splicing to conductors 

from the load side of contactor. The switch 
actuated by the plug is wired into the starter or 
contactor coil circuit and controls only this circuit. 
The starter or contactor is energized only when 

the plug is fully inserted and rotated to close the switch.

Standard Materials

Copper-free Aluminum

Accessory - Stainless Steel

Gasket – Silicon or Rubber 

Applications

SDPR Series interlock receptacles are used:  

Compliances

ANSI/ASME B 1.20.1 Pipe threads, General purpose 
(Inch)

ISO 228/1 Pipe threads where pressure- tight joints are

not made on the threads

NEMA 4, 4X 

IEC 60529

Standard Finishes

Epoxy painted (Munsell No. 7.5BG 6/1.5).

Model Number Logic

Series
Constant

SDPR

Current 
Rating Max.

30 : 30A
60 : 60A
75 : 75A
100 : 100A

00

Gangs or 
Pins

3P : 2P+1E 
4P : 3P+1E

00

Rated 
Voltage

22 : 220Vac 
25 : 250Vac
46 : 250Vdc

00

Rated 
Current 

000

Hub Type

DE : Dead end
FT : Feed Thru.

00

Hub 
Threads Type

P : BSPP threads
N : NPT threads

0

00

Hub Threads

16 : 1/2”
22 : 3/4”
28 : 1” 

Example 1) For non-hazardous area Receptacle & plug 75A 250Vdc 2P+1E NPT 1/2” 2 Hub SDPR 75 3P 25 75A FT N16
Example 2) For non-hazardous area Receptacle & plug 30A 460Vac 3P+1E PF 3/4” 1 Hub SDPR 30 4P 46 30A DE P22

SDPR 30

SDPR 60, 75, 100

catalog_eng-html.html
background image

B

Electrical Products

Enclosures / Controls / Panels

SDPR Series Receptacles & Plugs– Non-hazardous Area 

Receptacles & Plugs (Non-hazardous.)

Wet locations 
Rain-tight  
Water-tight 
Corrosion Resistant 

Copper Free 
Aluminum

Four Type

30A, 60A, 

75A, 100A 

Selection Table

PINS

RATED VOLTAGE

RETED INTERRUPTING
CAPACITY

220Vac 460Vac 250Vdc

220Vac 460Vac 250Vdc

220Vac 460Vac 250Vdc

220Vac 220Vac 460Vdc

5KA

5KA

2.5KA

20KA

15KA

10KA

20KA

15KA

10KA

20KA

15KA

10KA

DESCRIPTION

CAT. NO.

SDPR 30

2P+1E

3P+1E

SDPR 60

SDPR 75

SDPR 100

Technical Data

3P+1E

3P+1E

3P+1E

SDPR 30

2P+1E

3P+1E

3P+1E

3P+1E

SDPR 30 3P 22 30A DE 22

SDPR 30 4P 22 30A DE 22

SDPR 30 4P 46 30A DE 22

SDPR 60 4P 22 60A DE 22

SDPR 60 4P 46 60A DE 22

SDPR 60 4P 25 60A DE 22

SDPR 75 4P 22 75A DE 22

SDPR 75 4P 46 75A DE 22

SDPR 75 4P 25 75A DE 22

SDPR 100 4P 22 100A DE 22

SDPR 100 4P 46 100A DE 22

SDPR 100 4P 25 100A DE 22

220Vac

220Vac

460Vac

220Vac

460Vac

250Vdc

220Vac

460Vac

250Vdc

220Vac

460Vac

250Vdc

MODEL

PINS

RATED

VOLTAGE

SDPR 30 3P 22 30A DE 28

SDPR 30 4P 22 30A DE 28

SDPR 30 4P 46 30A DE 28

SDPR 60 4P 22 60A DE 28

SDPR 60 4P 46 60A DE 28

SDPR 60 4P 25 60A DE 28

SDPR75 4P 22 75A DE 28

SDPR 75 4P 46 75A DE 28

SDPR75 4P 25 75A DE 28

SDPR 100 4P 22 100A DE 28

SDPR 100 4P 46100A DE 28

SDPR 100 4P 25 100A DE 28

SDPR 30 3P 22 30A FT 22

SDPR 30 4P 22 30A FT 22

SDPR 30 4P 46 30A FT 22

SDPR 60 4P 22 60A FT 22

SDPR60 4P 46 60A FT 22

SDPR 60 4P 25 60A FT 22

SDPR 75 4P 22 75A FT 22

SDPR 75 4P 46 75A FT 22

SDPR 75 4P 25 75A FT 22

SDPR 100 4P 22 100A FT 22

SDPR 100 4P 46 100A FT 22

SDPR 100 4P 25 100A FT 22

SDPR 30 3P 22 30A FT 28

SDPR 30 4P 22 30A FT 28

SDPR30 4P 46 30A FT 28

SDPR 60 4P 22 60A FT 28

SDPR 60 4P 46 60A FT 28

SDPR 60 4P 25 60A FT 28

SDPR 75 4P 22 75A FT 28

SDPR 75 4P 46 75A FT 28

SDPR 75 4P 25 75A FT 28

SDPR 100 4P 22 100A FT 28

SDPR 100 4P 46 100A FT 28

SDPR 100 4P 25 100A FT 28

CAT.NO.

DEAD END

3/4”

1”

3/4”

1”

FEED THRU.

SDPR 60

SDPR 75

SDPR

100

3P+1E

SDPR 60

SDPR 75

SDPR 100

150

252

252

125

226

226

200

276

276

178

252

252

285

360

360

CAT.NO.

DIMENSIONS (MM)

A

B

C

D

E

F

Dimensions

225

225

225

SDPR 30

SDPR 60, 75, 100

catalog_eng-html.html
background image

Enclosures

/

Controls

/Panels

B

Enclosures / Controls / Panels

B44 _ B45

ELES Series Exit Sign

Explosion-proof
Rain-tight
Water-tight
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups C, D
NEMA 4, 4X
Zone 1, Zone 2 
II 2G Ex d II B IP 65 

Copper Free 
Aluminum

220Vac 4W or 8W

Heat Resistant 
Glass

Factory-Sealed

Halogen Lamps

In locations deemed hazardous due to the presence of flammable vapors or gases. 

In any building or enclosed area where people work 

where illuminated exit signs are required. 

To provide distinct, highly visible exit marking. 

To indicate the direction of travel to exits. 

Features

One or two halogen lamps (included) wired in parallel-to provide extra margin of light source reliability. 

Solid state circuit for extended lamp life in AC units. 

Green  letters or sign picture on white sign panel make word "exit" stand out boldly and clearly. 

Edge lighting characteristic of sign panel makes visibility excellent at all lighting levels. 

Factory-sealed flame-proof housing. 

Pendant, wall, and end bracket mounts provide universal installation options. 

Impact-resistant sign panel needs no guard – makes cleaning easy. 

Halogen lamps life time is three times higher than incandescent lamps.-reduces re-lamping cost 

Standard Materials

Copper-free Aluminum

Accessory - Stainless Steel 

Gasket – Silicon or Rubber 

Heat and impact resistant glass 

Applications

ELES Series Exit Signs are used:   

ELES 

Compliances

IEC 60079-0 Equipment- General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

NEC 500 / NEMA 4, 4X / IEC 60529

Standard Finishes

Epoxy painted (Munsell No. 7.5BG 6/1.5)

Certification

Certified KOSHA

(Korea Occupational Safety & Health Agency)

ELES 4W
ELES 8W

13kg
30kg

30min
30min

4W
8W

62mA

100mA

220Vac
220Vac

CAT. NO.

DIMENSIONS (MM)

RATED

VOLTAGE

ELEC.SPEC.

WEIGHT &

EMERGENCY TIME

RATED

CURRENT

WATTS

EMERGENCY

TIME

WEIGHT

Technical Data

ELES 4W
ELES 8W

300
352

230
312

100

84

340
392

170
252

CAT. NO. 

Dimensions

DIMENSIONS (MM)

BOX SIZE

3/4”

WIDTH

HEIGHT

DEPTS

X

Y

catalog_eng-html.html
background image

Flame-proof Type Panel System : SEPD &-C or SECP &-C Series

Explosion-proof / Rain-tight  / Water-tight / Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X / II 2G Ex d II C IP 65

Flame-proof Type Panel System SEPD - C & SECP - C Series

Explosion-proof / Rain-tight  / Water-tight / Corrosion Resistant

Cl. I, Div. 1&2, Groups B, C, D / NEMA 4, 4X / II 2G Ex d II B + H2 IP 65

Flame-proof Type Panel System SEPD & SECP Series

Specification of Panel System

Specification

Ex d II B + H2 T6  type

Circuit Breaker Panel Board

Control Panel Board

Control Panel Board

Circuit Breaker Panel Board

Ex d II C T6  type

NO.

Certificated
Basic Construction
Max Current
Max Voltage
IP Grade
Main Material
Temperature
Humidity
Altitude
Basic Finish

KOSHA
16-Circuit
255A
AC 220V
IP 65
AC 4C-T6

SEPD 40

SEPD 63

SECP 40

SECP 63

KOSHA
Large or Small
5A
AC 220V
IP 65
AC 4C-T6

-20

°

C ~ 40

°

C

95%

1000 m

Spray (Color : Munsel No. 7.5BG 6/1.5)

SEPD-C-SS
SEPD-C-SL
SEPD-C-DSL
SEPD-C-DLL
KOSHA
8 or 16 or 24 or 32-Circuit
255A
AC 220V
IP 54
AC 4A

SECP-C-SS
SECP-C-SL
SECP-C-DSL
SECP-C-DLL
KOSHA
9 or 18 or 27or 36 -Device
5A
AC 220V
IP 65
AC 4C-T6

Model No.

2
3
4
5
6
7
8
9

10
11

1

B

Panels

Enclosures / Controls / Panels

catalog_eng-html.html
background image

The diagram below is used to supply the positioning
of control devices for all modular enclosures. 
The center point is  0/0 which is consistent for all
enclosures. The positions increase from the center
outward and correlate with size of particular
enclosures

Flame-proof Type Custom-built Panels General Technical Descriptions

Control Position Diagram Usage

Control  Position  Diagram

Enclosures / Controls / Panel

B46 _ B47

Enclosures

/

Controls

/Panels

B

catalog_eng-html.html
background image

Flame-proof Type Custom-built Panels General Technical Descriptions 

Grounding

Internal and external ground terminations simplify grounding requirements

This apparatus can be used in the hazardous areas indicated on the plate so that use in the  other areas is
prohibited. (A plate is attached on the exterior of the apparatus.)

Because of dangerous electrical shock to the equipment operator SAMWHA products are provided with
means of grounding depends upon the particular style being used.

Maintenance & Caution Note

Power should be turned off to open the apparatus for Installation, inspection and Maintenance, 
and a proper security measures must be conducted to keep power off while it is open.
It is requested to exercise an extra caution to prevent damages to the junction parts at openings 
and closings, and to tighten bolts completely with a tool to avoid sticking of things on them.
An impact on or a dropping of the apparatus causes a lowering of quality so, a special handing is
demanded.
The rated voltage indicated on the apparatus should be observed.
Please inform SAMWHA if any problems related with the apparatus.

B

Panels(Circuit Breaker Panels)

Enclosures / Controls / Panels

catalog_eng-html.html
background image

Applications

SEPD custom-built panel boards are used with EJB series Terminal Box:

Copper Free
Aluminum

SEPD Series - Ex d II B + H2 T6  

Custom-built Panel Boards

Cl. I, Div. 1 & 2, Groups B, C, D / NEMA 4, 4X
II 2G Ex d II B+H2 IP 65

Explosion-proof / Rain-tight / Water-tight / 
Corrosion Resistant

Protection and control of electrical equipments and circuits such as lighting in hazardous locations or in damp,  

wet or corrosive condition

For Zone 1 & 2, Flame-proof type. (Ex d II B T6 + H2)

Indoors or outdoors in damp, wet, dusty, corrosive and hazardous locations

Where exposure to frequent or heavy rain, water, spray, moisture and humidity is common.

In areas which are hazardous due to the presence of hydrogen, gases and vapors or equivalent hazard such  as 

found in process industries, gas manufacturing plants.

Features

Main feed conduit openings at both top and bottom of junction compartment – allow main feed entry at either 
end of enclosure

To reduce installation costs, panels can be supplied with circuit breakers factory wired to terminal blocks  
mounted in the box.

Special Silicon cover gasket provides a water seal to meet IP65 requirements, and provides superior protection    

for enclosed equipment against water/corrosion.

Optional stainless steel hinges provide convenient and easy access for inspection, maintenance and systems 

changes

Main terminal block positioned to provide ample wire bending space – eliminates need for excessive bending of 
wires.

Permits selection of 1- ,2- ,3- pole breakers (10,000 amp AC interrupting capacity) with any number of Ground 
fault interrupters. (Single pole.)

Breaker actuators – spring loaded, self-locating – Feature simplified design for actuating 1- ,2- ,3-pole

breakers in any sequence.

Breakers  prewired to terminal block – provided with insulated neutral lug.

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Compliances

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500 

NEMA 4, 4X

IEC 60529

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

Technical Data 

Voltage  Range : AC 120V~220V

Enclosures / Controls / Panel

B48 _ B49

Enclosures

/

Controls

/Panels

B

catalog_eng-html.html
background image

Dimensions

Copper Free
Aluminum

SEPD Series - Ex d II B + H2 T6 

Custom-built Panel Boards

Cl. I, Div. 1 & 2, Groups B, C, D / NEMA 4, 4X
II 2G Ex d II B+H2 IP 65

Explosion-proof / Rain-tight / Water-tight / 
Corrosion Resistant

Front View

Mounting Holes 4 - Ø13

SEPD 40 

Max16 - Circuit

SEPD 63 

Max 32 - Circuit

Side View

Front View

Side View

Mounting Holes 4 - Ø13

Two

½

” 

Breather 
openings

Two

½

Breather 
openings

Two 

½

Drain
openings

Two

½

Drain
openings

Interior Front View

SEPD 40 Max 16 Circuit

1Pole

SEPD 40 Breaker box

SEPD 63 Breaker box

EJB 5040 Terminal box

SEPD 63 Max 32  Circuit

1Pole

Terminal 
block  16P

Terminal
block  16P

Bus Bar 3T-20  
16P

Terminal 
block  16P

Bus Bar 3T-20  
16P

Circuit Breaker

A

SEPD 40
SEPD 63

B

C

D

E

F

G

H

I

J

K

500

500

400

400

400

630

830

1060

415

415

437~451

437~451

165

165

316

316

15

15

335

335

363

363

(Unit : mm)

2

½

” Main Conduit

Circuit Breaker

Bus Bar 3T-20  
16P

B

Panels(Circuit Breaker Panels)

Enclosures / Controls / Panels

catalog_eng-html.html
background image

Hub Design 

(Drawing indicates position as looking into 
Hub opening of box)

Bottom View

Maximum Quantity for Drilled and Tapped Openings

Model No.

5040

NPT or PF

Metric thread

A (Bottom)

C

B or D

#16

M16

35

46

36

#22

M20

19

29

21

#28

M25

16

24

18

#36

M32

6

12

9

#42

M40

5

10

8

#54

M50

4

9

7

#70

M63

4

4

3

#82

M75

-

3

3

#104

M90

-

3

2

Drilled and tapped conduit openings will be evenly spaced and located in the area indicated on the location 

chart. Critical conduit opening locations may be indicated by supplying a diagram similar to the one shown at 

below indicating critical dimensions and locations

Specific conduit openings must be located dimensionally from box centerlines to conduit centerlines and from 
outside back surface of box to conduit centerline

Hub Area

Minimum Centers for Drilled and Tapped Openings and Hubs

Auto Position Slide Actuator Handle

#16/M16
#22/M20
#28/M25
#36/M32
#42/M40
#54/M50
#70/M63
#82/M75
#104/M90

39

44

47.5

56.5

62.5

71

80.5

87

103.5

49

52.5

61.5

67.5

76

85.5

92

108.5

56

65

71

79.5

89

95.5

112

72

78

86.5

96

102.5

119

84

92.5

102

108.5

125

99

108.5

115

131.5

118

124.5

141

129

145.5

162

#16/M16

#22/M20

#28/M25

#36/M32

#42/M40

#54/M50

#70/M63

#82/M75

#104/M90

Breaker actuators 
– spring loaded, self-locating

Spring  self -locator

Enclosures / Controls / Panel

B50 _ B51

Enclosures

/

Controls

/Panels

B

catalog_eng-html.html
background image

Applications

Copper Free
Aluminum

With ELC Lens 

Covers Series

With UE Control 
Devices Series

SECP Series - Ex d II B + H2 T6  

Custom-built Control Panels

Cl. I, Div. 1 & 2, Groups B, C, D / NEMA 4, 4X
II 2G Ex d II B+H2 IP 65

Explosion-proof / Rain-tight / Water-tight / 
Corrosion Resistant

as a means of grouping control stations for centralized process control in hazardous areas in minimum space

to provide the necessary push-buttons, pilot lights, selector switches and emergency switches

For Zone 1&2, Flame Proof type (Ex d II B T6+ H2)

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations

Where exposure to frequent or heavy rain, water, spray, moisture, and humidity is common ; such as : offshore 

drilling facilities, cooling towers, coal preparation and handling facilities and sewage and waste water treatment plant.

In areas which are hazardous due to the presence of hydrogen or gases and vapors of equivalent hazard such as;

found in process industries, gas manufacturing plants.

SECP custom-built control panels are used with Control unit:

Features

To reduce installation costs, panels can be supplied with control components factory wired to terminal blocks 

mounted in the box. Relays and other control devices can also be mounted in the boxes for special control  
functions.

Surface mounted control panels have the components assembled in the hinged cover, readily accessible for 
circuit checking and trouble shooting

Flat cover provides additional space for mounting a greater number of control devices.

Special Silicon cover gasket provides a water seal to meet IP65 requirements, and provides superior protection 
0for enclosed equipment against water/corrosion.

Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are 
broken.

Optional stainless steel hinges provide convenient and easy access for inspection, maintenance and systems 

changes

Glass cover can be factory installed to enable viewing of digital read out meters and devices such as Volt 

meters, Flow meters, Gas analyzers, Process receivers, Transmitters and Controllers

B

Panels(Control Panels)

Enclosures / Controls / Panels

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Compliances

IEC 60079-0 Equipment - General requirements

IEC 60079-1 Equipment protection by  flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

ISO 261 Metric screw threads

NEC 500 

NEMA 4, 4X

IEC 60529

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

Technical Data 

Voltage  Range : AC 120V~220V

catalog_eng-html.html
background image

Dimension & Installation Type 

Hub Design 

Drilled and tapped conduit openings will be evenly spaced and located in the area indicated on the location

chart. Critical conduit opening locations may be indicated by supplying a diagram similar to the one shown 
at below indicating critical dimensions and locations.

Specific conduit openings must be located dimensionally from box centerlines to conduit centerlines and from
outside back surface of box to conduit centerline.

Hub Area

Bottom View

(Drawing indicates position as looking into Hub opening of box)

Enclosures / Controls / Panel

B52 _ B53

Enclosures

/

Controls

/Panels

B

SECP 40-F  Flexible foot type

SECP 40-H  Hanger type

SECP 63-F  Flexible foot type

SECP 63-S   Stand type

catalog_eng-html.html
background image

Copper Free
Aluminum

With ELC Lens 

Covers Series

With UE Control 
Devices Series

SECP Series - Ex d II B + H2 T6  

Custom-built Control Panels

Cl. I, Div. 1 & 2, Groups B, C, D / NEMA 4, 4X
II 2G Ex d II B+H2 IP 65

Explosion-proof / Rain-tight / Water-tight / 
Corrosion Resistant

Maximum Quantity for Drilled and Tapped Openings

Model No.

5040

NPT or PF

Metric thread

A (Bottom)

C

B or D

#16

M16

35

46

36

#22

M20

19

29

21

#28

M25

16

24

18

#36

M32

6

12

9

#42

M40

5

10

8

#54

M50

4

9

7

#70

M63

4

4

3

#82

M75

-

3

3

#104

M90

-

3

2

Minimum Centers for Drilled and Tapped Openings and Hubs

#16/M16
#22/M20
#28/M25
#36/M32
#42/M40
#54/M50
#70/M63
#82/M75
#104/M90

39

44

47.5

56.5

62.5

71

80.5

87

103.5

49

52.5

61.5

67.5

76

85.5

92

108.5

56

65

71

79.5

89

95.5

112

72

78

86.5

96

102.5

119

84

92.5

102

108.5

125

99

108.5

115

131.5

118

124.5

141

129

145.5

162

#16/M16

#22/M20

#28/M25

#36/M32

#42/M40

#54/M50

#70/M63

#82/M75

#104/M90

B

Panels(Control Panels&

Circuit Breaker Panels)

Enclosures / Controls / Panels

catalog_eng-html.html
background image

Copper Free
Aluminum

SEPD-C Series - Ex d II C T6  

Custom-built Panel Boards

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 3, 3R / 
II 2G Ex d II C IP 54

Explosion-proof / Weather-tight / 
Weather-resistant  /  Wet location

Applications

Protection and control of electrical equipments and circuits such as lighting in hazardous locations or in damp, 
wet or corrosive condition.

For Zone 1 & 2, Flame-proof type. (Ex d II C T6)

Indoors or outdoors in damp, wet, dusty, corrosive and hazardous locations. 

Where exposure to frequent or heavy rain, water, spray, moisture and humidity is common.

In areas which are hazardous due to the presence of hydrogen, gases and vapors or equivalent hazard  such as 
found in process industries, gas manufacturing plants.

SEPD-C custom-built panel board s are used with Mounting Construction ( Used Section shape Steel ).

Features

To reduce installation costs, panels can be supplied with circuit breakers factory wired to terminal blocks 
mounted in the box.

Special Silicon cover gasket provides a water seal to meet IP65 requirements, and provides superior protection 

for enclosed equipment against water/corrosion.

Main terminal block positioned to provide ample wire bending space - eliminates need for excessive bending 

of wires.

Permits selection of 1- ,2- ,3- pole breakers (10,000 amp AC interrupting capacity) with any number of Ground 

fault interrupters. (Single pole)

Breaker actuators - Rotate selector type - Feature simplified design for actuating 1- ,2- ,3- pole breakers in 

any sequence.

Breakers  prewired to terminal block - provided with insulated neutral lug.

Main feed conduit openings at both top and bottom of junction compartment - allow main feed entry at

either end of enclosure.

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Compliance

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by   

flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, 

General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight

joints are not made on the threads

ISO 261 Metric screw thread

NEC 500 

NEMA 4, 4X

IEC 60529

Certification

Certified KOSHA (Korea Occupational Safety & 

Health Agency)

Technical Data 

Voltage  Range : AC 120V~220V

Enclosures / Controls / Panel

B54 _ B55

Enclosures

/

Controls

/Panels

B

catalog_eng-html.html
background image

Copper Free
Aluminum

SEPD-C Series - Ex d II C T6  

Custom-built Panel Boards

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 3, 3R / 
II 2G Ex d II C IP 54

Explosion-proof / Weather-tight / 
Weather-resistant  /  Wet location

Dimension & Installation Type

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

Front View

Side View

Front View

Side View

A

SEPD-C-SS
SEPD-C-SL

SEPD-C-DLS
SEPD-C-DLL

B

C

D

E

F

G

H

I

J

K

320

320

654

654

292

292

292

292

380

600

600

600

55

55

55

55

375

375

375

375

50

50

50

50

261

261

261

261

162

162

162

162

425

425

425

425

992~1022

1212~1242

1212~1242

1212~1242

245

245

554

554

(Unit : mm)

B

Panels(Circuit Breaker Panels)

Enclosures / Controls / Panels

Two

½

” 

Breather 
openings

Two

½

Drain
openings

Two

½

” 

Breather 
openings

Two

½

Drain
openings

Two

½

” 

Breather 
openings

Two

½

Drain
openings

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

Two

½

” 

Breather 
openings

Two

½

Drain
openings

Mounting Holes 4 - Ø12

Mounting Holes 4 - Ø12

Mounting Holes 4 - Ø12

SECP-C-SS 

Max 8 - Circuit

SECP 40-H  Hanger type

SECP-C-DLS 

Max 24-Circuit

SECP-C-DLL 

Max 32-Circuit

Front View

Side View

Front View

Side View

catalog_eng-html.html
background image

Interior Front View

25

26

27

28

25

26

27

28

25

26

27

28

25

26

27

28

Front View

(Drawing indicates position as looking into Hub opening of box)

Bottom View

SECP-C-DLS & DLL

SECP-C-SS & SL

Hub Design 

Drilled and tapped conduit openings will be evenly 
spaced and located in the area indicated on the 
location chart. Critical conduit opening locations 
may be indicated by supplying a diagram similar to 
the one shown at below indicating critical dimensions 
and locations.

Specific conduit openings must be located 
dimensionally from box centerlines to conduit 
centerlines and from outside back surface of box to 
conduit centerline.

Minimum Centers for Drilled and Tapped Openings and Hubs

#16/M16
#22/M20
#28/M25
#36/M32
#42/M40
#54/M50
#70/M63
#82/M75
#104/M90

39

44

47.5

56.5

62.5

71

80.5

87

103.5

49

52.5

61.5

67.5

76

85.5

92

108.5

56

65

71

79.5

89

95.5

112

72

78

86.5

96

102.5

119

84

92.5

102

108.5

125

99

108.5

115

131.5

118

124.5

141

129

145.5

162

#16/M16

#22/M20

#28/M25

#36/M32

#42/M40

#54/M50

#70/M63

#82/M75

#104/M90

Housing pivots 180˚ for removal 
of branch cover.

Enclosures / Controls / Panel

B56 _ B57

Fix Bracker

Fork Shape

Bracker

Circuit
Breaker

Cover

Enclosures

/

Controls

/Panels

B

catalog_eng-html.html
background image

Copper Free
Aluminum

SEPD-C Series - Ex d II C T6  

Custom-built Panel Boards

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 3, 3R / 
II 2G Ex d II C IP 54

Explosion-proof / Weather-tight / 
Weather-resistant  /  Wet location

SECP-C-SS & SL

SECP-C-DLS & DDL

Bottom View

Bottom View

Maximum Quantity for Drilled and Tapped Openings

Model No.

SECP-C-

SS & SL

SECP-C-

DLS & DLL

NPT or PF

Metric thread

A (Bottom)

B or D

C

A (Bottom)

B or D

C

#16

M16

26

49

52

58

49

120

#22

M20

15

30

30

35

30

69

#28

M25

8

23

20

20

23

50

#36

M32

7

14

14

14

14

28

#42

M40

5

9

10

13

9

26

#54

M50

3

7

7

6

7

17

#70

M63

2

3

3

5

3

9

#82

M75

2

3

3

4

3

7

#104

M90

2

2

2

3

2

5

B

Panels(Circuit Breaker Panels)/

(Control Panels)

Panels(Circuit Breaker Panels) / (Control 

Enclosures / Controls / Panels

Hub Area

Hub Area

catalog_eng-html.html
background image

Standard Materials

Copper-free Aluminum

Accessory : Stainless Steel

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Compliance

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by

flameproof enclosures “d”

ANSI/ASME B 1.20.1 Pipe threads, 

General purpose (Inch)

ISO 228/1 Pipe threads where pressure-

tight joints are not made on the threads

ISO 261 Metric screw thread

NEC 500 

NEMA 4, 4X

IEC 60529

Certification

Certified KOSHA (Korea Occupational Safety & 

Health Agency

Technical Data 

Voltage  Range : AC 120V~220V

Copper Free
Aluminum

With ELC Lens 

Covers Series

With UE Control 
Devices Series

SECP-C Series - Ex d II B + H2 T6  

Custom-built Control Panels

Applications

as a means of grouping control stations for centralized process control in hazardous areas in minimum space

to provide the necessary pilot lights, selector switches and ampere meter, volt meter, buzzer

For Zone 1 & 2, Flame Proof type (Ex d II C)

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations

Where exposure to frequent or heavy rain, water, spray, moisture, and humidity is common ; such as : offshore 

drilling facilities, cooling towers, coal preparation and handling facilities and sewage and waste water treatment   
plant.

In areas which are hazardous due to the presence of hydrogen or gases and vapors of equivalent hazard such as ;
found in process industries, gas manufacturing plants.

SECP-C custom-built control panels are used with Control unit :

Features

To reduce installation costs, panels can be supplied with control components factory wired to terminal blocks 
mounted in the box. Relays and other control devices can also be mounted in the boxes for special control 
functions.

Surface mounted control panels have the components assembled in the hinged cover, readily accessible for 

circuit checking and trouble shooting.

Special Silicon cover gasket provides a water seal to meet IP65 requirements, and provides superior protection 

for enclosed equipment against water/corrosion.

Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are 
broken.

Glass cover can be factory installed to enable viewing of digital read out meters and devices such as Volt 

meters, Flow meters, Gas analyzers, Process receivers, Transmitters and Controllers

Cl. I, Div. 1 & 2, Groups B, C, D / NEMA 4, 4X
II 2G Ex d II C IP 65

Explosion-proof / Rain-tight / Water-tight / 
Corrosion Resistant

Enclosures / Controls / Panel

B58 _ B59

Panels)

Enclosures

/

Controls

/Panels

B

catalog_eng-html.html
background image

Copper Free
Aluminum

With ELC Lens 

Covers Series

With UE Control 
Devices Series

SECP-C Series - Ex d II B + H2 T6  

Custom-built Control Panels

Dimension & Installation Type

A

SECP-C-SS
SECP-C-SL

SECP-C-DLS
SECP-C-DLL

B

C

D

E

F

G

H

I

J

K

320

320

654

654

292

292

292

292

380

600

600

600

55

55

55

55

375

375

375

375

50

50

50

50

261

261

261

261

162

162

162

162

425

425

425

425

992~1022

1212~1242

1212~1242

1212~1242

245

245

554

554

(Unit : mm)

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X
II 2G Ex d II C IP 65

Explosion-proof / Rain-tight / Water-tight / 
Corrosion Resistant

B

Panels(Control Panels)

Enclosures / Controls / Panels

Two

½

” 

Breather 
openings

Two

½

Drain
openings

Two

½

” 

Breather 
openings

Two

½

Drain
openings

Two

½

” 

Breather 
openings

Two

½

Drain
openings

Two

½

” 

Breather 
openings

Two

½

Drain
openings

Mounting
Holes 4 - Ø12

Mounting Holes 4 - Ø12

Mounting Holes 4 - Ø12

Mounting
Holes 4 - Ø12

Front View

Side View

Front View

Side View

SECP-C-SS (Max  9–Device)

SECP-C-SL  (Max 18-Device)

SECP-C-DLS  

Max  27-Device

SECP-C-DLL  

Max  36-Device

Front View

Side View

Front View

Side View

catalog_eng-html.html
background image

Interior Front View

Front View

(Drawing indicates position as looking into Hub opening of box)

Housing pivots 180˚ for removal 
of branch cover.

Example SECP-C-DLL
Max 36 Device

Bottom View

Hub Design 

Drilled and tapped conduit openings will be evenly 
spaced and located in the area indicated on the 
location chart. Critical conduit opening locations 
may be indicated by supplying a diagram similar to 
the one shown at below indicating critical dimensions 
and locations.

Specific conduit openings must be located 
dimensionally from box centerlines to conduit 
centerlines and from outside back surface of box to 
conduit centerline.

Minimum Centers for Drilled and Tapped Openings and Hubs

#16/M16
#22/M20
#28/M25
#36/M32
#42/M40
#54/M50
#70/M63
#82/M75
#104/M90

39

44

47.5

56.5

62.5

71

80.5

87

103.5

49

52.5

61.5

67.5

76

85.5

92

108.5

56

65

71

79.5

89

95.5

112

72

78

86.5

96

102.5

119

84

92.5

102

108.5

125

99

108.5

115

131.5

118

124.5

141

129

145.5

162

#16/M16

#22/M20

#28/M25

#36/M32

#42/M40

#54/M50

#70/M63

#82/M75

#104/M90

Enclosures / Controls / Panel

B60 _ B61

SECP-C-DLS & DLL

SECP-C-SS & SL

Fix Bracker

Fork Shape

Bracker

Circuit
Breaker

Cover

Enclosures

/

Controls

/Panels

B

catalog_eng-html.html
background image

Copper Free
Aluminum

SECP-C Series - Ex d II C T6  

Custom-built Control Panels

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4R / 
II 2G Ex d II C IP 65

Explosion-proof / Rain-tight / Water-tight / 
Corrosion Resistant

Bottom View

Bottom View

SECP-C-SS & SL

SECP-C-DLS & DLL

Maximum Quantity for Drilled and Tapped Openings

Model No.

SECP-C-

SS & SL

SECP-C-

DLS & DLL

NPT or PF

Metric thread

A (Bottom)

B or D

C

A (Bottom)

B or D

C

#16

M16

26

49

52

58

49

120

#22

M20

15

30

30

35

30

69

#28

M25

8

23

20

20

23

50

#36

M32

7

14

14

14

14

28

#42

M40

5

9

10

13

9

26

#54

M50

3

7

7

6

7

17

#70

M63

2

3

3

5

3

9

#82

M75

2

3

3

4

3

7

#104

M90

2

2

2

3

2

5

Custom Build 

Type

Switch Rack Assemblies 

Applications

To provide a complete motor control center in one integrated package.

Outdoors and indoors

In damp, wet or corrosive locations such as sewage treatment plants, lumber mills, marine installations, 

and food preparation areas.

In areas made hazardous due to the presence of flammable vapors or gases, such as petroleum refineries, 

chemical and petrochemical plants, gas gathering plants, pipeline compressor stations, and drilling rigs, both 
onshore and offshore.

In areas where hazardous dusts are present, such as coal handling facilities, grain processing and handling 

plants, and certain food process industries.

Free-standing switch rack assemblies are used:

Features

Complete factory assembled and wired switch racks.

Pre-drilled bus boxes allow for quick and easy changing or adding of components.

Complete assembly covered under one order, eliminates engineering costs, additional costs of placing separate 

orders with several vendors for various components, and assembly and scheduling problems at job site.

Wiring is simple. After switch rack is in place, feeders are connected to the main bus and connections made 

from starters motors. No other field wiring is necessary.

Maintenance time and costs are reduced by having controls grouped. Work is performed in one location instead 

of moving from one control to another in various locations.

Custom built racks to meet your exact requirements are a SAMWHA specialty. Complete quotations will be 
supplied for any job, large or small.

B

Panels(Control Panels / 

Switch Rack)

Enclosures / Controls / Panels

Hub Area

Hub Area

catalog_eng-html.html
background image

Construction

All hazardous area enclosures for motor starters, combination motor starters, circuit breakers. motor circuit
protectors, instrument enclosures, panel-boards, main bus, fittings, receptacles, and lighting fixtures shall be
made and supplied by the manufacturer. 

Manufacturer shall retain permanent records of all motor control racks and shall have the capability of 

duplicating, or replacing, any fully-assembled rack or rack component.

Manufacturer to assume responsibility for construction, purchase/manufacturer of components, complete 

circuit continuity testing, and testing of mechanical functions of components.

Standard Materials

Rack frames - Structural steel, bolted and welded.

Components - Copper free aluminum.

Standard Finishes

Rack frame - Hot Dip Galvanized Steel or Spray (Color : Munsell No. 7.5BG 6/1.5)

Components - Spray (Color : Munsell No. 7.5BG 6/1.5)

Options

Rack frame finish - Custom ordering colors

Options listed for individual components can be incorporated in complete switch racks.

Rack Frame Design

Switch rack, either single or double face as required, shall be rigid, free-standing structures. 

Racks shall be factory-welded, assembled and fabricated.

Mounting feet shall be 100mm

×

50mm shape steel.

End mounting feet will be welded to the upright.

Mounting feet shall be anchored at the job site with 

Ø

16 diameter bolts.

Anchor bolts and mounting pads will be the responsibility of the user.

Maximum horizontal spacing between mounting legs shall not exceed 4 meter. 

(Specific dimensions to be determined by the manufacturer.)

Grounding

Grounding lug with appropriate wire capacity will be provided at each end of frame.

Enclosures / Controls / Panel

B62 _ B63

Enclosures

/

Controls

/Panels

B

catalog_eng-html.html
background image

Custom Build 

Type

Switch Rack Assemblies 

Canopy (Sun-Shade)

Canopy(Sun-shade) shall be factory-welded, assembled.
Roofing material shall be Stainless Steel or Epoxy painted steel. Canopy roof trusses, cross channels, 
roof material, and mounting hardware shall be shipped assembled for quick installation at the job site.

All fittings shall be made and provided by the manufacturer.

Fittings

Seals and unions will be provided for each incoming and outgoing conduit as required.

All interconnections between components shall be done by the manufacturer with galvanized rigid conduit, 

and conduit fittings as required to meet the hazardous classification.

Interconnecting conduits to be provided with conduit seals as required.

All incoming and outgoing rack conduit entrances shall include conduit seals as required by the hazardous 

location specified.

Such seals will be provided by the manufacturer and will not be filled where field wiring is to be introduced.

Conduit Boxes, Outlet Boxes, Device Boxes

Conduit boxes, outlet boxes, and device boxes shall be SAMWHA Conduit fittings.

Seals will be standard SAMWHA sealing fittings. (SVD drain type or SHF universal type, SVF vertical type)

Unions will be SAMWHA union couplings EU series.

Breathers and Drains shall be SAMWHA products.

Wiring

Standard wire shall be copper only, 600 volt, 75

°

C minimum rating.

No power wire less than 4 SQ shall be used.

Control wire shall be 1.5 SQ or 2.5 SQ minimum.

Drawings

Standard drawings supplied for customer approval shall include complete rack wiring diagram, component data,
nominal weight of the rack, and overall rack dimensions.

B

Panels(

Switch Rack

)

Enclosures / Controls / Panels

catalog_eng-html.html
background image

Enclosures / Controls / Panel

B64 _ B65

Enclosures

/

Controls

/Panels

B

MEMO

catalog_eng-html.html
background image

Optimized Products With Long-Term Experience

Mainly used for plant construction, buildings and housing construction, Samwha's industrial

fittings are the result of our long-term development. 

With our exceptional quality and services, these optimized products enable a remarkable cost

reduction.  

catalog_eng-html.html
background image

Smart  +  Technology  +  Human

Contents

Industrial Fittings

Composition Connector

SWCC-CP Series  Ex d II C / SWCC-CB Series  Ex d II C /
SWCC-CD Series  Ex d II C

SWCC-CP Series  Flame-proof Ex d Composition Connector
SWCC-CB Series  Flame-proof Ex d Composition Connector
SWCC-CD Series  Flame-proof Ex d Composition Connector

Outlet Boxes

Hazardous area Type & Non Hazardous area Type
SERB Series - Ex d II C Outlet Boxes
SIRB Series - Ex e II Outlet Boxes 
SNRB Series - Non Hazard. Outlet Boxes 4-Way

Device Boxes

SXDB Series - Non Hazard. Single Gang Device Boxes

Elbows

SX Series - Ex d II C  Elbows
SL Series - Ex d II C Angle Elbows

Flexible Fittings

EPF Series - Ex d II C Flexible Fittings
PVF Series - Ex e II PVC Jacketed Flexible Fittings
EDF Series - Non Hazard. Expansion/Deflection Fitting

Sealing Fittings

SVF Series / SHF Series / SDF Series - Ex d II C  Sealing Fittings

Compound & Fiber

SEACOM A - Compound / SEACOM X - Fiber

Conduit Outlet Bodies

Conduit Outlet Bodies & Cover
F7 Series - Ex e II  Conduit Outlet Bodies Cover & Gasket
F8 Series - Ex e II Conduit Outlet Bodies Cover & Gasket
MOGUL Series - Non Hazard.  Conduit Outlet Bodies Cover & Gasket

Union Couplings

EU Series - Ex d II C  Union Couplings

Plugs & Adapters, Sockets

EAG Series - Ex d II C  EAG Adapters / ESG Series - Ex d II C
ESG Sockets / FPG Series - Ex d II C  FPG Stopping Plugs

EAG Series - Ex d II C  EAG Adapters / ESG Series - Ex d II C  ESG Sockets
FPG Series  Stopping Plug

Nipples & Couplings, Normal Bends

FNG Series  Nipples / FNG & FNGC Series - Ex d II C
Hazardous area type / FNGS Series - Non Hazard.  
Non- hazardous Areatype
SVC Series -Ex d II C  SVC Couplings
SNB Series -Non Hazard. Rigid Elbows

Bushings

FB Series -Non Hazard.  Bushings (Malleable Iron)
ZB Series-Non Hazard.  Bushings (Zinc Die Casting)
EPD16 / UAE 16 - Ex d II C  For automatic Water Drainage and
Continuous ventilation.

Junction Boxes

SJB Series-Non Hazard.  Steel Junction Boxes
Steel Utility Boxes & Covers
Water-Tight Surface Mounting  Switches & Receptacles Boxes
Water-Tight Surface Mounting Receptacles Boxes
Surface Mounting Box
Water-Tight Surface Mounting General Use Snap Switches

C2
C3
C5
C7

C9
C10
C12
C13

C14

C15
C17

C19
C20
C21

C22

C24

C25
C27
C29
C31

C33

C35
C36
C38

C40
C42
C43

C44
C45

C46

C47
C48

C49
C50
C50

C

C

Industrial 
Fittings

catalog_eng-html.html
background image

Flame-proof Type Composition Connector (Single Packing Type) 
SWCC-CP Series - Ex d II C T6

Cl. I, Div. 1 & 2, Groups A, B, C, D

NEMA 4, 4X

Zone 1, Zone 2

II 2G Ex d II C IP65

Explosion-proof

Rain-tight

Water-tight

Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D

NEMA 4, 4X

Zone 1, Zone 2

II 2G Ex d II C IP65

Explosion-proof

Rain-tight

Water-tight

Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D

NEMA 4, 4X

Zone 1, Zone 2

II 2G Ex d II C IP65

Explosion-proof

Rain-tight

Water-tight

Corrosion Resistant

SWCC-CP Series  Ex d II C / SWCC-CB Series  Ex d II C / SWCC-CD Series  Ex d II C

Flame-proof Type Composition Connector (Copound Barrier Type)
SWCC-CB Series - Ex d II C T6

Flame-proof Type Composition Connector (Double Packing Type)
SWCC-CD Series - Ex d II C T6

C

Composition Connector

Industrial Fittings

catalog_eng-html.html
background image

For Un-amoured

Cables

Auto Drain Type
with a Flexible
Fitting

High Flexibility
Flexible Fitting

Quick Installation

Single Packing
Cable Gland with
Cable Clamps

SWCC-CP Series

Flame-proof Ex d Composition Connector

Applications

SWCC-CP Type indoor and outdoor composition connector with a flexible fitting for use in Zone1, 
Zone2 hazardous areas with all types of Un-armoured cable, providing mechanical cable retention 
and an environmental seal on the cable outer sheath.

Standard Materials

Brass Extruded bar 

EN12168: 1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

Seal Packing 

Silicon or Rubber

Standard Finishes

Brass 

Natural or Nickel Plated

Compliances / Approvals

IEC 60079-0  Equipment - General requirements

IEC 60079-1  Equipment protection by flameproof enclosures “d”

IEC 60529 Degree of protection provided by enclosures (IP Code)

NPT 

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

BSPP  

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

Metric 

ISO 965-1, ISO 965-3 medium fit (6g) for external threads

Features

The SWCC-CP type range is designed and tested to IEC 60079-0 & 1. All metallic composition 
connector components are manufactured from the same grade of material. Brass locknuts are 
produced in the same CU Zn39PB3 grade as the composition connector.

Auto drain type with a flexible fitting

For use with conduit

High flexible conduit

Quick installation

Single packing cable gland with cable clamps

Model 

Design Specification 

IEC Ex Code of Protection Category

EN 50262 Mechanical Classifications 

Continuous Operating Temperature 

Ingress Protection Rating 

Cable Type 

Sealing Technique 

Sealing Area(s) 

Optional Accessories 

Un-armoured

Displacement Seal - Single Packing

Outer Sheath

Adaptor/Reducer

SWCC-CP

IEC 60079-0 & 1

Ex d II C

Retention = Class B, 
Impact = Level 6

-20

to +80

IP65

TECHNICAL DATA

Industrial Fittings

C2_ C3

Industrial Fittings

C

Explosion-proof / 
Rain-tight / 
Water-tight / 
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D / 
NEMA 4, 4X / 
II 2G Ex d II C IP65

catalog_eng-html.html
background image

For Un-amoured

Cables

Auto Drain Type
with a Flexible
Fitting

High Flexibility
Flexible Fitting

Quick Installation

Single Packing
Cable Gland with
Cable Clamps

SWCC-CP Series

Flame-proof Ex d Composition Connector

Cable Gland Selection Table (Dimensions & Construction)

4.0

7.0

3.5

6.5

10.5

6.2

12.7

16.5

10.6

15.6

20.6

13.7

18.7

23.7

19.9

25.9

30.9

28.3

36.3

40.3

23.6

28.6

32.6

37.6

47.6

52.6

48.2

51.2

56.2

64.2

T

-

T2

T

-

T2

T

-

T2

T

-

T2

T

-

T2

T

-

T2

T

-

35

40

44

T2

T

-

T2

63

T

-

T

-

T2

T

-

T2

T

-

T2

T

-

T2

T

-

T2

T

-

T2

T

-

35

40

44

T2

T

-

T2

63

T

-

8.0

11.0

8.0

11.0

15.0

11.0

17.5

21.3

17.0

22.0

27.0

19.0

24.0

29.0

28.0

34.0

39.0

39.0

47.0

51.0

34.0

39.0

43.0

48.0

58.0

63.0

59.0

62.0

67.0

75.0

SWCC - CP 16

SWCC - CP 22

SWCC - CP 28

SWCC - CP 36

SWCC - CP 42

SWCC - CP 54

SWCC - CP 70

SWCC - CP 82

SWCC-CP 104

M20

M25

M32

M40

M50

M50

M63

M75

M100

38.0

45.0

51.5

66.0

65.0

79.0

110.0

119.0

152.0

1/2"

3/4"

1"

1 1/4"

1 1/2"

2"

2 1/2"

3"

4"

15.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

34.0

34.0

34.0

47.0

40.0

45.0

67.5

81.0

86.0

90.0

94.5

95.0

104.0

104.0

121.0

137.5

151.0

165.0

34.0

42.0

48.0

60.0

62.0

75.0

105

114.0

142.0

CAT.NO.

Available Entry Threads

Minimum

Thread

Length (A)

Cable Out Diameter

Max. of Approx. Length 

Across

Flats

Across

Corners

Min

No

Max 

Gland (L1) Coupling (L2)

Metric

NPT or BSPP

Standard

Max Max 

C

Composition Connector

Industrial Fittings

Explosion-proof / 
Rain-tight / 
Water-tight / 
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D /
NEMA 4, 4X / 
II 2G Ex d II C IP65

catalog_eng-html.html
background image

For Un-amoured   
Cables

Quick Installation

Compound Barrier

Type

Auto Drain Type 
with a Flexible 
Fitting

Applications

SWCC-CB Type indoor and outdoor composition connector with a flexible fitting for use in Zone1, 
Zone2 hazardous areas with all types of Un-armoured cable,  providing mechanical cable retention and
an environmental seal on the cable outer sheath.

Standard Materials

Brass Extruded bar 

EN12168: 1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

Seal Packing 

Silicon or Rubber

Standard Finishes

Brass 

Natural or Nickel Plated

Compliances / Approvals

IEC 60079-0  Equipment - General requirements

IEC 60079-1  Equipment protection by flameproof enclosures “d”

IEC 60529 Degree of protection provided by enclosures (IP Code)

NPT 

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

BSPP  

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

Metric 

ISO 965-1, ISO 965-3 medium fit (6g) for external threads

Features

The SWCC-CB type range is designed and tested to IEC 60079-0 & 1.
All metallic composition connector components are manufactured from the same grade of material. 
Brass locknuts are produced in the same CU Zn39PB3 grade as the composition connector.

Auto drain type with a flexible fitting

For use with conduit

High flexible conduit

Quick installation

Compound barrier type

For use multi pair cable.

Model 

Design Specification 

IEC Ex Code of Protection Category

EN 50262 Mechanical Classifications 

Continuous Operating Temperature 

Ingress Protection Rating 

Cable Type 

Sealing Technique 

Sealing Area(s) 

Optional Accessories 

Un-armoured

Compound barrier type

Outer Sheath

Adaptor/Reducer

SWCC-CB

IEC 60079-0 & 1

Ex d II C

Retention = Class B, 
Impact = Level 6

-20

to +80

IP65

TECHNICAL DATA

Industrial Fittings

C4_ C5

SWCC-CB Series  

Flame-proof Ex d Composition Connector

Industrial Fittings

C

Explosion-proof / 
Rain-tight / 
Water-tight / 
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D /
NEMA 4, 4X / 
II 2G Ex d II C IP65

catalog_eng-html.html
background image

SWCC-CB Series  

Flame-proof Ex d Composition Connector

Cable Gland Selection Table (Dimensions & Construction)

8.5

13.0

19.0

26.0

32.0

40.0

50.0

62.0

74.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

34.0

34.0

34.0

47.0

40.0

45.0

67.5

81.0

86.0

34.0

42.0

48.0

60.0

62.0

75.0

105

114.0

142.0

38.0

45.0

51.5

66.0

65.0

79.0

110.0

119.0

152.0

M20

M25

M32

M40

M50

M50

M63

M75

M100

15.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

1/2"

3/4"

1"

1 1/4"

1 1/2"

2"

2 1/2"

3"

4"

CAT.NO.

Available Entry Threads

Minimum

Thread

Length (A)

Bore Capacity

Max. of Approx. Length 

Across

Flats

Across

Corners

Min

Max 

Gland (L1) Coupling (L2)

Metric

NPT or BSPP

Standard

Max Max 

SWCC - CB 16

SWCC - CB 22

SWCC - CB 28

SWCC - CB 36

SWCC - CB 42

SWCC - CB 54

SWCC - CB 70

SWCC - CB 82

SWCC - CB 104

C

Composition Connector

Industrial Fittings

Explosion-proof / 
Rain-tight / 
Water-tight / 
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D /
NEMA 4, 4X / 
II 2G Ex d II C IP65

For Un-amoured   
Cables

Quick Installation

Compound Barrier

Type

Auto Drain Type 
with a Flexible 
Fitting

catalog_eng-html.html
background image

Industrial Fittings

C6_ C7

Industrial Fittings

C

For Un-amoured

Cables

Auto Drain Type
with a Flexible
Fitting

High Flexibility
Flexible Fitting

Quick Installation

Double Packing
Cable Gland

SWCC-CD Series  

Flame-proof Ex d Composition Connector

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X /
II 2G Ex d II C IP65

Explosion-proof / Rain-tight / Water-tight / Corrosion /
Resistant

Applications

SWCC-CD Type indoor and outdoor composition connector with a flexible fitting for use in Zone1, 
Zone2 hazardous areas with all types of Un-armoured cable, providing mechanical cable retention 
and an environmental seal on the cable outer sheath.

Standard Materials

Brass Extruded bar 

EN12168: 1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

Seal Packing 

Silicon or Rubber

Standard Finishes

Brass 

Natural or Nickel Plated

Compliances / Approvals

IEC 60079-0  Equipment - General requirements

IEC 60079-1  Equipment protection by flameproof enclosures “d”

IEC 60529 Degree of protection provided by enclosures (IP Code)

NPT 

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

BSPP  

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

Metric 

ISO 965-1, ISO 965-3 medium fit (6g) for external threads

Features

The SWCC-CD type range is designed and tested to IEC 60079-0 & 1.
All metallic composition connector components are manufactured from the same grade of material. 
Brass locknuts are produced in the same CU Zn39PB3 grade as the composition connector.

Auto drain type with a flexible fitting

For use with conduit

High flexible conduit

Quick installation

Double packing cable gland

Model 

Design Specification 

IEC Ex Code of Protection Category

EN 50262 Mechanical Classifications 

Continuous Operating Temperature 

Ingress Protection Rating 

Cable Type 

Sealing Technique 

Sealing Area(s) 

Optional Accessories 

Un-armoured

Displacement Seal - Single Packing

Outer Sheath

Adaptor/Reducer

SWCC-CD

IEC 60079-0 & 1

Ex d II C

Retention = Class B, 
Impact = Level 6

-20

to +80

IP65

TECHNICAL DATA

catalog_eng-html.html
background image

For Un-amoured

Cables

Auto Drain Type
with a Flexible
Fitting

High Flexibility
Flexible Fitting

Quick Installation

Double Packing
Cable Gland

SWCC-CD Series  

Flame-proof Ex d Composition Connector

Cable Gland Selection Table (Dimensions & Construction)

4.0

7.0

3.5

6.5

10.5

6.2

12.7

16.5

10.6

15.6

20.6

13.7

18.7

23.7

19.9

25.9

30.9

28.3

36.3

40.3

23.6

28.6

32.6

37.6

47.6

52.6

48.2

51.2

56.2

64.2

8.0

11.0

8.0

11.0

15.0

11.0

17.5

21.3

17.0

22.0

27.0

19.0

24.0

29.0

28.0

34.0

39.0

39.0

47.0

51.0

34.0

39.0

43.0

48.0

58.0

63.0

59.0

62.0

67.0

75.0

SWCC - CD 16

SWCC - CD 22

SWCC - CD 28

SWCC - CD 36

SWCC - CD 42

SWCC - CD 54

SWCC - CD 70

SWCC - CD 82

SWCC - CD 104

M20

M25

M32

M40

M50

M50

M63

M75

M100

38.0

45.0

51.5

66.0

65.0

79.0

110.0

119.0

152.0

1/2"

3/4"

1"

1 1/4"

1 1/2"

2"

2 1/2"

3"

4"

15.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

34.0

34.0

34.0

47.0

40.0

45.0

67.5

81.0

86.0

90.0

94.5

95.0

104.0

104.0

121.0

137.5

151.0

165.0

34.0

42.0

48.0

60.0

62.0

75.0

105

114.0

142.0

CAT.NO.

Available Entry Threads

Minimum

Thread

Length (A)

Cable Out Diameter

Max. of Approx. Length 

Across

Flats

Across

Corners

Min

No

Max 

Gland (L1) Coupling (L2)

Metric

NPT or BSPP

Standard

Max Max 

C

Explosion-proof / 
Rain-tight / 
Water-tight / 
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D /
NEMA 4, 4X / 
II 2G Ex d II C IP65

Composition Connector

Industrial Fittings

T

-

T2

T

-

T2

T

-

T2

T

-

T2

T

-

T2

T

-

T2

T

-

35

40

44

T2

T

-

T2

63

T

-

catalog_eng-html.html
background image

Industrial Fittings

C8_ C9

Industrial Fittings

C

Outlet Boxes

Industrial Fittings

Hazardous Area Type & Non Hazardous Area Type

Hazardous area type

Outlet Boxes

Device Boxes

Elbows

Flexible Fittings

Sealing Fittings

Compound & Fiber

Conduit Outlet Bodies

Union Couplings

Plug & Adaptor, Socket

Nipples & Couplings &
Normal Bends

Bushing

Drains & Breathers

Junction Boxes

SERB Series - Ex d II C
SIRB Series - Ex e II

SNRB Series

SXDB Series

FNGS Series

SNB Series

EDF Series

MOGUL Series

BP Series
FB Series
ZB Series

SJB Series

SX Series - Ex d II C
SL Series - Ex d II C

SEACOM A - Compound
SEACOM X - Fiber

F7 Series - Ex e II
F8 Series - Ex e II

EU Series  - Ex d II C

EPF Series - Ex d II C
PVF Series - Ex e II

SVF Series - Ex d II C
SHF Series - Ex d II C
SVD Series - Ex d II C

EAG Series  - Ex d II C
ESG Series - Ex d II C
FPG Series - Ex d II C

EPD 16 - Ex d II C
UAB 16 - Ex d II C
UPD 12 - Ex d II C
EAB 16 - Ex d II C

Steel Utility Boxes & Covers
Water-tight Surface Mounting Switches & Receptacles Boxes
Surface Mounting Box
Water-tight Surface Mounting General Use Snap Switches

FNG & FNGC Series  - Ex d II C

SVC Series - Ex d II C

Non Hazardous area type

Wire Inserting Instructions

Maximum number and size of conductors allowed in trade sizes of SAMWHA Conduit outlet elbow

IEC(SQ)

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

400

500

630

16 (1/2

)

22 (3/4

)

28 (1

)

36 (1-1/4

)

42 (1-1/2

)

54 (2

)

70 (2-1/2

)

82 (3

)

104 (4

)

AWG & MCM

3

5

9

15

20

33

55

76

128

14

2

4

7

13

17

28

47

66

110

12

2

4

6

11

15

24

41

57

96

10

2

3

6

10

13

21

36

50

84

8

1

2

4

8

10

17

28

40

67

6

1

2

4

7

9

15

25

36

60

4

1

1

3

5

7

11

19

26

44

2

1

2

4

6

9

16

22

37

1

1

2

3

4

7

12

17

29

1/0

1

2

3

5

9

13

22

2/0

1

2

3

4

8

11

18

4/0

1

1

2

3

6

9

15

250

1

1

3

5

7

12

300

1

1

2

4

6

10

400

1

2

3

4

8

500

1

1

2

4

6

600

1

2

3

5

800

1

1

2

4

1

1

3

catalog_eng-html.html
background image

3-Way or 4-Way

Applications

SERB series conduit outlet boxes are installed in conduit systems within hazardous areas to:
Provide protection against exterior explosion where acetylene, hydrogen and other hazardous 
gases are present Protect conductors in threaded rigid conduit Act as pull and splice boxes
Interconnect lengths of conduit Change conduit direction Provide access to conductors for
maintenance and future system changes

Features

SERB series conduit outlet boxes have: Taper threaded hubs to provide ground continuity 
Smooth integral hub bushing to protect conductor insulation when pulling Threaded cover openings
Surface covers furnished with boxes Neoprene

o

-ring gasket and green ground screw are both standard.

Standard Materials

Bodies & Covers - Cast Iron or Ductile

Standard Finishes

Bodies & Covers - Hot Dip Galvanized 

or Electro Zinc Plate & Epoxy Painted

Threads - Oil touch up or Electro Zinc Plated

Compliances / Approvals

IEC 60079-0  Equipment - General requirements

IEC 60079-1  Equipment protection by flameproof enclosures

d

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

UL Standard : 886

Size Ranges

SERB - 1/2

to 2

SERB 01 - 1/2

to 1

Certification 

Certified KOSHA 

(Korea Occupational Safety & Health Agency)

Conduit Outlet Boxes With Covers SERB Series

SERB Series - Ex d II C

Outlet Boxes

Explosion-proof / Rain-tight / Water-tight / 
Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X / 
Zone 1, Zone 2 / II 2G Ex d II C IP 65

Model Number Logic

Outlet type

01 : 3-Way Y type
None : 4-Way X type

Hub threads Spec.

N : NPT threads
P : PF threads

Example 1) Outlet Box Flame proof type 3-Way Y type NPT 36 SERB 01 N36
Example 2) Outlet Box Flame proof type 4-Way X type PF 28 SERB P28

Hub threads size

Series 
Constant

O

SERB

O

OO

Outlet Boxes

Industrial Fittings

C

catalog_eng-html.html
background image

Industrial Fittings

C10 _ C11

Industrial Fittings

C

Option Table

SERB Series

SERB 16~54

4Way

None

With 1 Plug

With 2 Plug

With 3 Plug

None

With 1 Plug

With 2 Plug

3Way

2Way

1Way

3Way

2Way

1Way

SERB 01 16~28

Option

Dimensions

IP Construction

SERB - Hub Size

Dimension(MM)

Ø

A

B

C

D

E

Ø

F

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

100

100

100

126

126

160

140

140

140

174

174

222

75

75

75

87

95

127

86

86

86

106.5

106.5

143

13.5

21

24

32.5

35

42.5

8

8

8

8

8

8

SERB - 4-Way

SERB 01 - 3-Way

catalog_eng-html.html
background image

4-Way

Applications

SIRB series conduit outlet boxes are installed in conduit systems within hazardous areas to:
Provide protection against exterior explosion where acetylene, hydrogen and other hazardous 
gases are present. Protect conductors in threaded rigid conduit. Act as pull and splice boxes. 
Interconnect lengths of conduit. Change conduit direction. Provide access to conductors for 
maintenance and future system changes 

Features

SIRB series conduit outlet boxes have: Taper threaded hubs to provide ground continuity.
Smooth integral hub bushing to protect conductor insulation when pulling 4 Cover fix bolts.
Surface covers furnished with boxes. Neoprene gasket and green ground screw are both standard.

Standard Materials

Bodies & Covers - Cast Iron or Ductile

Gaskets-Neoprene or Rubber

Standard Finishes

Bodies & Covers - Hot Dip Galvanized or 
Electro Zinc Plate & Epoxy Painted

Threads - Oil touch up or Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment - General requirements

IEC 60079-7 Equipment protection by increased safety 

e

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

UL Standard: UL886

Size Ranges

Hub - 1/2

to 2

Conduit Outlet Boxes With Covers SERB Series

SIRB Series - Ex e II 

Outlet Boxes

Increased safety  type / Rain-tight / 
Water-tight / Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X / 
Zone 1, Zone 2 / II 2G Ex d II C  IP 65

Model Number Logic

Dimensions

Hub threads Spec.

N : NPT threads
P : PF threads

Example 1) Outlet Box Increased safety type NPT 36 SIRB N36
Example 2) Outlet Box Increased safety type PF 28 SIRB P28

Hub 
threads size

Select
Constant

O

SIRB

OO

SERB - Hub

Size

Dimension(MM)

Ø

A

B

C

D

E

Ø

F

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

95
95
95

125
125
160

59
63
76
85
95

118

134
134
138
170
170
228

85
85
85

106
106
143

7
7
7
9
9

10

1/2

3/4

1

1-1/4

1-1/2

2

SIRB Series

SIRB 16~54

4Way

3Way

2Way

1Way

Option

None

With 1 Plug

With 2 Plug

With 3 Plug

Option

Outlet Boxes

Industrial Fittings

C

Certification 

Certified KOSHA 

(Korea Occupational Safety & Health Agency)

catalog_eng-html.html
background image

Industrial Fittings

C12 _ C13

Industrial Fittings

C

Model Number Logic

Hub threads Spec.

N : NPT threads
P : PF threads

Example 1) Outlet Box Non-haza. NPT 36  #22 Hub type Cover SNRB N36 22HB
Example 2) Outlet Box Non-haza. PF 28  Blank type Cover SNRB P28 BK

Hub threads 
size

Select
Constant

O

SNRB

OO

Cover type

ST : Standard type
HB : 

¾”

Hub type

BK : Blank type

OO

Covers and Gaskets 

Non-hazardous
area  type 

KEPIC-EN 
Certificate

Applications

SNRB Series are installed in threaded rigid conduit systems to:

Act as junction boxes

Act as pull outlets

Features

Compact, shallow design

Multiple tapped conduit openings and pipe plugs for versatility

Surface mounting can be obtained by nailing box to concrete form through mounting lug.

Drilled mounting lugs

Four conduit bosses spaced 90

°

apart on sides and one boss on back.

Blank or drilled and tapped bodies (with 4 side bosses tapped and plugged, plus blank back boss)

Standard Materials

Bodies & Covers - Cast Iron or Ductile

Gaskets-Neoprene or Rubber

Standard Finishes

Bodies & Covers - Hot Dip Galvanized or 

Electro Zinc Plate & Epoxy Painted

Threads - Oil touch up or Electro Zinc Plated

Size Ranges

Hub -1/2

(with

½”

adaptor) to 1

Certification 

UL Standard: UL 514A

KEPIC-EN Certi. No. : EN - 335

SNRB Series - Non Hazard.

Outlet Boxes 4-Way

Dimensions

Hub type cover

Blank type cover

Gaskets : Neoprene

Weather-tight / Weather-resistant
Wet location / NEMA 3, 3R

SNRB Series

SIRB 16~54

4Way

3Way

2Way

1Way

Option

None

With 1Plug

With 2Plug

With 3Plug

Option

catalog_eng-html.html
background image

Model Number Logic

Example 1) Single Gang Consent type Device Box Dead End type NPT 1

SCDB DE N28

Example 2) Single Gang Switch type Device Box Feed Thru type PF 3/4

SSDB FT P2

Hub threads
Spec.

N : NPT

threads

P : PF

threads

Model type

SCDB :
Consent type
SSDB : 
Switch type

SXDB

Hub type

DE : Dead End 

(1 Hub)

FT : Feed Thru

(2Hub)

OO

O

Hub threads 
size

OO

SXDB Series

Consent type

Switch type

3 / 4

1

Selection Table

Dead End
Feed Thru
Dead End
Feed Thru

SCDB DE 22

SCDB FT 22

SCDB DE 28

SCDB FT 28

SCDB DE 22

SCDB FT 22

SCDB DE 28

SCDB FT 28

Cover & Gasket

KEPIC-EN Certificate

Applications

Accommodate wiring devices.

Act as pull boxes for conductors in a conduit system.

Provide openings to make splices and taps in conductors.

Provide access to conductors for maintenance and future system changes

Connect conduit sections

SXDB Series for mounting surface devices on floor or bench (used with single gang covers)

Cast device boxes are installed to:

Features

Suitable for use in wet locations when used with gasketed covers

Mounting lugs standard on most boxes

Tapered threaded hubs with integral bushing

Available for surface mounting (with mounting lugs) as listed.

Internal green ground screw standard on boxes

Standard Materials

Bodies - Cast Iron or Ductile

Covers - Steel

Gaskets - Neoprene or Rubber

Standard Finishes

Bodies & Covers - Hot Dip Galvanized 

or Electro Zinc Plate & Epoxy Painted

Threads - Oil touch up or Electro Zinc Plated

Size Ranges

Hub - 

¾”

or 1

Certification 

KEPIC-EN Certi. No. : EN - 335

SXDB Series - Non Hazard.

Single Gang Device Boxes

Hub type

Dead End type (1 Hub)

Feed Thru type (2 Hub)

Dimensions

Model Type

Device Boxes

Industrial Fittings

C

Consent type 

Switch type 

catalog_eng-html.html
background image

Industrial Fittings

C14 _ C15

Elbows

Industrial Fittings

Industrial Fittings

C

2-Way or 3-Way

Applications

Serve as pulling fittings.

Make bends in conduit system.

Provide openings for splicing.

Connect and change direction of conduit run.

Allow connections for branch runs.

Permit access to conductors for maintenance.

SX elbow Series are installed in conduit systems within hazardous areas to:

Materials

Maximum volume for bends within a compact overall size.
Screw on cover for ease of installation and removal.
Cover opening on an angle, permitting conductors to be pulled straight through either hub.
Taper threaded hubs and integral bushing for rigid threaded conduit.

Standard Materials

Bodies & Covers - Cast Iron or Ductile

Standard Finishes

Bodies & Covers -Hot Dip Galvanized or 
Electro Zinc Plate & Epoxy Painted

Threads - Oil touch up or Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment - General requirements

IEC 60079-1 Equipment protection by flameproof enclosures

d

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

UL Standard : 886

Size Ranges

Hub - 1/2

to 2

SX Series - Ex d II C

Elbows

Explosion-proof / Weather-tight / 
Weather-resistant / Wet location

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 3, 3X / 
Zone 1, Zone 2 / II 2G Ex d II C IP 54

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

Selection Table

SX Series

2Way

3Way

Below type

Elbow type

T type

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

SXB 16

SXB 22

SXB 28

SXB 36

SXB 42

SXB 54

SXL 16

SXL 22

SXL 28

SXL 36

SXL 42

SXL 54

SXT 16

SXT 22

SXT 28

SXT 36

SXT 42

SXT 54

Model Number Logic

Example 1) Elbow 2-Way Y type NPT 28 SXB N28
Example 2) Elbow 3-Way T type PF 42 SXT P42

Hub threads Spec.

N : NPT threads
P : PF threads

Select 
constant

SX

Elbow type

B : 2-Way Y type
L : 2-Way L type
T : 3-Way T type

O

O

Hub threads 
size

OO

catalog_eng-html.html
background image

Dimensions

SXB-Size

Dimension(MM)

A

B

C

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

57.5

57.5

67

80

90

101

36.5

36.5

44.5

54

57

65

35

36.8

40.3

48

53.5

57.5

SXT-Size

Dimension(MM)

A

B

C

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

57.5

57.5

67

80

90

101

48

50

57.5

69

74.5

81.5

15

17.5

21

25.5

28.5

34.3

SXL-Size

Dimension(MM)

A

B

C

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

57.5

57.5

67

80

90

101

48

50

57.5

69

74.5

81.5

15

17.5

21

25.5

28.5

34.3

Elbows

Industrial Fittings

C

SXB-Size

SXT-Size

SXL-Size

SX Series - Ex d II C

Elbows

Explosion-proof / Weather-tight / 
Weather-resistant / Wet location

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 3, 3X / 
Zone 1, Zone 2 / II 2G Ex d II C IP 54

catalog_eng-html.html
background image

Industrial Fittings

C16 _ C17

Industrial Fittings

C

Explosion-proof / Weather-tight
Weather-resistant / Wet location

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 3, 3R /
Zone 1, Zone 2 / II 2G Ex d II C IP 54

Applications

SL series elbows are installed in conduit systems within hazardous areas to: 
Provide protection against exterior explosion where acetylene, hydrogen. and other hazardous gases 
are present Protect conductors in threaded rigid conduit. Change conduit direction

Features

Smooth integral hub bushing to protect conductor insulation when pulling.

Standard Finishes

Bodies -Hot Dip Galvanized or Electro Zinc Plate & Epoxy Painted

Threads – Oil touch up or Electro Zinc Plated

Certification 

Certified KOSHA (Korea Occupational Safety & Health Agency)

SL Series - Ex d II C 

Angle Elbows

Model Number Logic

Thread type

MM : Male to male
FM : Female to male
FF: Female to female

Hub threads Spec.

N : NPT threads
P : PF threads

Example 1) Elbow Female to male 45 degree NPT 28 SLFM 45 N28

Example 2) Elbow male to male 90 degree PF 36 SLMM 90 P36

Hub threads size

Select
Constant

O

SL

O

Angle

45 – 45 degree
90 – 90 degree

OO

OO

Compliances / Approvals

IEC 60079-0 Equipment - General requirements

IEC 60079-1 Equipment protection by flameproof enclosures

d

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

UL Standard : 886

Standard Materials

Cast Iron or Ductile

Size Ranges

1/2

to 4

Selection Table

SL Series

Male to male

Female to male

Female to female

45degree

90degree

45degree

90degree

45degree

90degree

#16 (1/2

#22 (3/4

#28 (1

#36 (1-1/4

#42 (1-1/2

#54 (2

)

SLMM45 16

SLMM45 22

SLMM45 28

SLMM45 36

SLMM45 42

SLMM45 54

SLMM90 16

SLMM90 22

SLMM90 28

SLMM90 36

SLMM90 42

SLMM90 54

SLFM45 16

SLFM45 22

SLFM45 28

SLFM45 36

SLFM45 42

SLFM45 54

SLFM90 16

SLFM90 22

SLFM90 28

SLFM90 36

SLFM90 42

SLFM90 54

SLFF45 16

SLFF45 22

SLFF45 28

SLFF45 36

SLFF45 42

SLFF45 54

SLFF90 16

SLFF90 22

SLFF90 28

SLFF90 36

SLFF90 42

SLFF90 54

SLMM 45

°

SLMM 90

°

SLFM 45

°

SLFF 45

°

SLFM 90

°

SLFF 90

°

catalog_eng-html.html
background image

Explosion-proof / Weather-tight
Weather-resistant / Wet location

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 3, 3R /
Zone 1, Zone 2 / II 2G Ex d II C IP 54

SL Series - Ex d II C 

Angle Elbows

Dimensions

SLFM - Size

Dimension(MM)

A

B

C

D

E

F

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

1/2

3/4

1

1-1/4

1-1/2

2

33
38
47

58.5

67

75.3

35
41

48.5

58

65.5

80

31
38

45.5

55

61.5

75

27.0
30.5
34.5

39.5

45.5

52.5

41.5
46.5

52

57

63

72

SLFF - Size

Dimension(MM)

A

B

F

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

33

38

47

58.5

67

75.3

1/2

3/4

1

1-1/4

1-1/2

2

41.5

46.5

52

57

63

72

SLMM - Size

Dimension(MM)

A

C

D

E

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

35

41

48.5

58

65.5

80

31

38

45.5

55

61.5

75

27.0

30.5

34.5

39.5

45.5

52.5

1/2"

3/4"

1"

1-1/4"

1-1/2"

2"

Elbows

Industrial Fittings

C

SLFM - Size

SLFF - Size

SLMM - Size

catalog_eng-html.html
background image

Industrial Fittings

C18 _ C19

Industrial Fittings

C

Applications

EPF couplings are used: In hazardous areas where a flexible member is required 
in a conduit system to accomplish difficult bends, or to allow for movement or 
vibration of connected equipment or units

Features

Rugged design to withstand explosive pressure (Class I).
Mechanical abuse. Liquid-tight for wet locations.
For use where lack of space makes use of rigid conduit difficult.
Wire duct liner in sizes 1/2

to 4

insulates against grounds and burnthrough from short circuit.

No bonding jumpers required, metallic braid provides continuous electrical path.
EPF has two threaded male or female end union.

Standard Materials

End fittings:
1/2

to 4

– Brass or Stainless Steel

1/2

to 4

have a type Stainless Steel braid

Standard Finishes

Brass natural - Electro Nickel Plated

Stainless Steel - Natural

Compliances / Approvals

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof enclosures

d

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

BS 3643 ISO metric screw threads. Principles and basic data.

UL Standard : 886

EPF Series - Ex d II C 

Flexible Fittings

Explosion-proof / Weather-tight / 
Weather-resistant / Wet location

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 3, 3R
Zone 1, Zone 2 / II 2G Ex d II C IP 54 

Model Number Logic

Thread type

MM : Male to male
FM : Female to male
FF: Female to female

Hub threads size

Example 1) Flexible fittings Female to male NPT 28 L=1.0M EPF FM N28 100
Example 2) Flexible fittings male to male PF 36 L=750mm EPF MM P36 75

Tube length

Unit : cm

Select 
Constant

O

EPF

OO

Hub threads Spec.

M : Metric threads
N : NPT threads
P : PF threads

O

OO

Dimensions

EPF –

Hub Size

Dimension(MM)

Dimension(MM)

ØD

Ød

EPF –

Hub Size

ØD

Ød

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

19

27

34
42
49

13.4

19.1

25.4
32.9
39.3

#54 (2

)

#70 (2-1/2

)

#82 (3

)

#104 (4

)

64

79

93

120

51.8

65.2

76.5

101

Certification 

Certified KOSHA (Korea Occupational Safety & Health Agency)

Flexible Fittings

Industrial Fittings

catalog_eng-html.html
background image

Increased safety type / Rain-tight
Water-tight / Corrosion Resistant

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X
Zone 1, Zone 2 / II 2G Ex e II IP 65 

Applications

PVF couplings are used: In hazardous areas where a flexible member is required 
in a conduit system to accomplish difficult bends, or to allow for movement or vibration of 
connected equipment or units.

Features

Mechanical abuse. Liquid-tight for wet locations.
For use where lack of space makes use of rigid conduit difficult.
Wire duct liner in sizes 1/2

to 4

insulates against grounds and burnthrough from short circuit.

No bonding jumpers required, metallic braid provides continuous electrical path.
PVF has two threaded male or female end union.

Standard Materials

End fittings:
1/2

to 4

– Brass or Stainless Steel

1/2

to 4

have a pliable conduits with PVC jackets

Standard Finishes

Brass natural - Electro Nickel Plated

Stainless Steel – Natural

Tube jacket - PVC

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

Compliances / Approvals

IEC 60079-0 Equipment – General requirements

IEC 60079-7 Equipment protection by increased safety 

e

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

BS 3643 ISO metric screw threads. Principles and basic data.

UL Standard: 886

PVF Series - Ex e II 

PVC Jacketed Flexible Fittings

Model Number Logic

Thread type

MM : Male to male
FM : Female to male
FF: Female to female

Hub threads size

Example 1) Flexible fittings Female to male NPT 28 L=1.0M PVF FM N28 100
Example 2) Flexible fittings male to male PF 36 L=750mm PVF MM P36 75

Tube length

Unit : cm

Select  
Constant

O

PVF

OO

Hub threads Spec.

M : Metric threads
N : NPT threads
P : PF threads

O

OO

Dimensions

EPF –

Hub Size

Dimension(MM)

Dimension(MM)

ØD

Ød

EPF –

Hub Size

ØD

Ød

#17 (1/2

)

#25 (3/4

)

#30 (1

)

#38 (1-1/4

)

#50 (1-1/2

)

23

30.5

36.5

45
57

16.6

23.8

29.3
37.1
49.1

#63 (2

)

#76 (2-1/2

)

#83 (3

)

#101(4

)

71.5

85

91

110

62.6

76

81

100.2

Flexible Fittings

Industrial Fittings

C

catalog_eng-html.html
background image

Industrial Fittings

C20 _ C21

Industrial Fittings

C

Dimensions

KEPIC-EN

Certificate

Applications

EDF Series can be installed indoors, outdoors, buried underground, or embedded in concrete in 
non-hazardous areas. EDF

s are used with standard rigid conduit or PVCrigid conduit. 

(PVC requires rigid metal conduit nipples and rigid metal-to-PVC conduit adapters.) 
EDF

s provide a flexible and watertight connection for protection of conduit wiring systems 

from damage due to movement.
Typical applications include:

Underground conduit feeder runs

Runs between sections of concrete subject to relative movement

Runs between fixed structures    

Conduit entrances in high-rise buildings

Bridges     

Marinas, docks, piers

Features

EDF Series accommodate the following movements without collapsing or fracturing the conduit, and damaging
the wires it contains:

- Watertight flexible neoprene outer jacket is corrosion resistant and protects the grounding 

strap and  the attachment points of the hubs.

- Tinned copper flexible braid grounding straps as sure grounding continuity.
- Stainless steel jacket clamps for strength and corrosion resistance.
- Standard tapered electrical threads fit standard rigid conduit.

Axial expansion or contraction up to 3/4

Angular misalignment of the axes of the coupled conduit runs in any direction to 30

°

Parallel misalignment of the axes of coupled conduit runs in any direction to 3/4

Standard Materials

Hubs – Cast Iron or Ductile

Outer jacket – Molded Neoprene

Jacket clamps – Stainless Steel

Grounding straps – Tinned copper flexible braid

Size Ranges

1

~ 6

Standard Finishes

Hub – Hot Dip Galvanized or Electro Zinc Plate & Epoxy Painted

Neoprene – Natural (black)

Threads – Oil touch up or Electro Zinc Plated

Certifications and Compliances

UL Standard: 514B

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

KEPIC-EN Certi. No. : EN - 335

EDF Series - Non Hazard.

Expansion/Deflection Fitting

Water-tight / Corrosion Resistant

EDF-Size

Dimension(MM)

A

B

C

#28 (1

)

#42 (1-1/2

)

#54 (2

)

#82 (3

)

#104 (4

)

#150 (6

)

140
140
160
175
175
175

90
90

105
164
164
220

190
190
208
240
240
240

Hub threads Spec.

M : Metric threads
N : NPT threads

Example 1) Expansion/Deflection Fitting NPT 4

EDF N104

Example 2) Expansion/Deflection Fitting PF 6

EDF P150

Hub threads size

1

~ 6

Select 
Constant

O

EDF

OO

1. Axial expansion / 

contraction

2. Angular misalignment.

3. Parallel misalignment.

Model Number Logic

catalog_eng-html.html
background image

Explosion-proof / Weather-tight /

Weather-resistant / Wet location

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 3, 3R
Zone 1, Zone 2 /  II 2G Ex d II C

SVF (Vertical Type)

SHF (Universal Type)

SVD (Drain Type)

Applications

Sealing fittings are to: Restrict the passage of gases, vapors or flames from one portion of the 
electrical installation to another at atmospheric pressure and normal ambient temperatures. 
Limit explosions to the sealed-off enclosure. Limit pre-compression or

pressure piling

in conduit

systems.

Sealing fittings are required: At each entrance to an enclosure housing an arcing or sparking device 
when used in Class 1, Division 1 and 2 hazardous locations, To be located as close as practicable and, 
in no case, more than 18

from such enclosures. At each entrance of 2

size or larger to an enclosure or 

fitting housing terminals, splices or taps when used in class Division 1 hazardous locations. To be located
as close as practicable and, in no case, more than 18

from such enclosures. In conduit systems when

leaving Class 1, Division 1 or Division 2 hazardous locations. In cable systems when the cables either do not
havea gas/vapor tight continuous sheath or are capable of transmitting gases or vapors through the cable
core when those cables leave the Class 1, Division 1 or Division 2 hazardous locations.

Features

Sealing fittings include: Minimum turning radius. Large openings with threaded closures to
provide easy access to conduit hubs for making dams. Integral bushings in conduit hubs to
protect conduct or insulation from damage. Taper-tapped hubs to insure ground continuity.
Sealing fittings are available for installation in either vertical only or in both horizontal or vertical
positions. Sealing fittings for installation at any angle; the cove rs with opening for sealing
compound can be properly.

Compliances / Approvals

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flame proof enclosures

d

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

UL Standard: 886

Standard Materials

Bodies – Cast Iron or Ductile

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

Size Ranges

Hub – 1/2

to 4

Standard Finishes

Bodies -Hot Dip Galvanized or Electro 

Zinc Plate & Epoxy Painted

Threads – Oil touch up or Electro Zinc Plated

SVF Series / SHF Series / 
SDF Series - Ex d II C  

Sealing Fittings

Sealing Fittings

Industrial Fittings

C

catalog_eng-html.html
background image

Industrial Fittings

C22 _ C23

Industrial Fittings

C

Dimensions

Model Number Logic

Example 1) Sealing Fitting Universal or horizontal type NPT 28 SHF N28

Example 2) Sealing Fitting Drain type PF 36 SVD P36

Hub threads Spec.

N : NPT threads
P : PF threads

Select 
constant

S

Model

VF : Vertical type
HF : Universal type
VD : Drain type

OO

O

Hub threads 
size

OO

Note

SAMWHA sealing fitting are approved for use in hazardous locations only when SEACOM X fiber and SEACOMA Sealing Compound are used to make the seal.

Seals are installed in conduit runs to prevent the passage of gases,vapors or flames from one portion of the electrical installation to another through the
conduit, limiting any explosion to the enclosure and preventing pre-compression or

pressure piling

SVF - Size

SHF - Size

SVD - Size

SHF - Size

Dimension(MM)

C

B

A

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (2-2/1

)

#82 (3

)

#104 (4

)

98
96

120
134
146
165
190
217
245

44
49
60
72
79
94

117
134

156.5

32
38
44
55
62
76
96

111
135

SVF - Size

Dimension(MM)

C

B

A

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (2-2/1

)

#82 (3

)

#104 (4

)

83
98

106
126
142
163
185
204
230

60
71
81
97

114
136
157
186
238

33
38
44
55
61
76
96

111
135

SHF - Size

Dimension(MM)

C

B

A

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (2-2/1

)

#82 (3

)

#104 (4

)

82
94

109
126
143
160
185
205

233.5

42
47
59
69

83.5
96.5

116
124
173

32
38
44
55
61
78
96

111

136.5

SVF

SHF

catalog_eng-html.html
background image

For Sealing Fittings

and Hubs

Applications

SEACOM A Sealing Compound: Forms a seal around each electrical conductor and between them and
inside of the sealing fitting to restrict the passage of gases, vapors or flames through the sealing fitting 
at atmospheric pressure and at normal ambient temperatures.
SEACOM X fiber: Forms a dam between the integral bushing of the sealing fitting and the end of the 
conduit and around the electrical conductors entering the hub.

Features

SEACOM A Sealing compound is a water soluble powder, that can be easily mixed and poured.
The compound, unusually dense, expands slightly when hardening and bonds to inner walls of
sealing fittings.

SEACOM X fiber is a mineral wool that packs easily, forming around each conductor.

Compound hardens in 50~70 minutes.

The mixing ratio of compound to water is about two to one.

Standard Materials

SEACOM A : Compound

SEACOM X : Fiber

Size Ranges

SEACOM A Compound 1kg or 5kg

SEACOM X Fiber 120g or 600g

SEACOM A-Compound / SEACOM X-Fiber

SEACOM  A

SEACOM  X

Note

SAMWHA sealing fitting are approved for use in hazardous locations only when
SEACOM X fiber and SEACOM A Sealing Compound are used to make the seal.

Compound&Fiber

Industrial Fittings

C

catalog_eng-html.html
background image

Industrial Fittings

C24 _ C25

Conduit Outlet Bodies

Industrial Fittings

Industrial Fittings

C

Conduit Outlet Bodies & Cover

Wire Inserting Instructions

Maximum number and size of conductors allowed in trade sizes of SAMWHA conduit bodies

Conduit Trade Size

Model No.

Hub

4

25

2

35

1

50

2/0

70

3/0

95

4/0

120

250

127

300

152

350

177

400

203

500

253

600

304

700

355

750

380

900

456

AWG

KS IEC

1/0

3

#104 (4

)

#82 (3

)

#70 (2-1/2

)

#54 (2

)

#42 (1-1/2

)

#36 (1-1/4

)

#28(1

)

Conductor Size SQ(

), AWG & MCM

F7 : LL104, LR104

F7 : LT104, LTB104, 

LX104

)

F7 : LB104

F7 : LC82

F7 : LB82

F7 : LL82, LR82

F7 : LT82, LX82

F7 : LTB82

F7 : LC70

F7 : LB70

F7 : LT70

F7 : LL70, LR70

F7 : LC54, LB54

F7 : LT54, LTB54,

LX54

F7 : LL54, LR54

F7 : LC42, LT42, 

LTB42, LX42

F7 : LL42, LR42

F7 : LB42

F7 : LT36, LTB36, 

LX36

F7 : LC36, LB36

F7 : LL36, LR36

F7 : LC28, LB28, 

LL28, LR28, LT28,    
LTB28, LX28

all

thru

side

all

all

all

all

thru

side

thru

side

all

all

thru

side

all

all

thru

side

all

all

all

all

thru

side

all

all

all

59

59

59

59

34

34

34

34

34

34

34

21

21

21

21

21

15

15

15

15

8

8

8

6

6

6

6

3

50

50

50

50

28

28

28

28

28

28

28

18

18

18

18

18

12

12

12

12

7

7

7

3

5

3

5

42

42

42

42

24

24

24

24

24

24

24

15

15

15

15

15

10

10

3

10

3

6

6

3

3

31

31

31

31

17

17

17

17

17

17

3

11

11

11

11

11

7

7

7

4

3

26

26

26

26

14

14

14

14

3

14

9

9

9

3

9

3

3

6

3

21

21

21

21

3

12

12

3

3

3

7

3

7

5

17

17

3

17

3

10

3

6

3

14

14

14

5

11

3

11

3

10

3

3

catalog_eng-html.html
background image

Conduit Outlet Bodies & Cover

Installation

The following procedures should be used to insure the reliability of wiring pulled through conduit bodies.

Use approved wire pulling compound that is compatible with wire insulation.

Start by pulling all the wires through one hub and train the wires through the cover opening.

Loop the wires in a large circle as shown on the attached sketch and feed through the other hub.

Pull all the wires together until the loop is approximately 6

in diameter for 2

trade size or less  

and 10 times the O.D. of the largest wire for 2-1/2

trade size and larger.

Flip the loop 180

°

into a training loop. (Make sure the wires are not crossed.) Pull out the loop one wire 

at a time. It is best to start pulling out the training loop using the wires closest to the inside to the loop.

Do not pull the wires taut or any tighter than necessary to place the cover on the conduit body.

Station a person at the 

training loop

to safely guide the wires during pulling. To prevent insulation

damage use a blunt tool, if necessary, to keep the wire from binding or jamming. The use of a well
rounded tool, such as a length of conduit or a round dowel, will assist in turning the loop while

preventing damage to the wire insulation

Conduit Outlet Bodies Construction

MODEL

SIZE

ELBOW TYPE

LB

LL LR

LT

LTB

LX

LC

#16(1/2")

#22(3/4")

#28(1")

#36(1-1/4")

#42(1-1/2")

#54(2")

#70(2-1/2")

#82(3")

#104(4")

#16(1/2")

#22(3/4")

#28(1")

#36(1-1/4")

#42(1-1/2")

#54(2")

#28(1")

#42(1-1/2")

#54(2")

#82(3")

#104(4")

F7

Ex e II

F8

Ex e II

MOGUL

Non. Haza.

Conduit Outlet Bodies

Industrial Fittings

C

TYPE 

C

CONDUIT BODY

TYPE 

T

TYPE 

LB

CONDUIT BODY

catalog_eng-html.html
background image

Industrial Fittings

C26 _ C27

Industrial Fittings

C

Applications

Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing.
Connect and change direction of conduit run. Allow connections for branch runs.
Permit access to conductors for maintenance.

Features

High tensile strength and ductility. High corrosion-resistance, high impact and shock resistance.
Roomy interiors; more wiring space. No wire damage; smooth, rounded integral bushing in each 
hub protects conductor insulation. Accurately tapped, threads for tight, rigid joints and ground continuity.
Completely interchangeable with Crouse-Hinds Form7 Series or Appleton FM7 Series. 
Applications and installation dimensions are also interchangeable.

Standard Materials

Bodies & Cover - Ductile or Cast Iron

Gasket – Neoprene or Rubber

Standard Finishes

Bodies & Covers – Hot Dip Galvanized or Electro Zinc Plate & Epoxy painted.

Threads – Oil touch up or Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment – General requirements

IEC 60079-7 Equipment protection by increased safety 

e

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

UL Standard: 514B

Size Ranges

1/2

to 4

F7 Series - Ex e II  

Conduit Outlet Bodies Cover & Gasket

Increased safety type / 
Rain-tight / 
Water-tight

Cl. I, Div. 1 & 2, Groups A, B, C, D / 
NEMA 3, 3X / 
Zone 1, Zone 2 / II 2G Ex e II IP 44

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency) 

KEPIC-EN Certi. No. : EN - 335

KEPIC-EN 

Certificate

catalog_eng-html.html
background image

F7 Series - Ex e II  

Conduit Outlet Bodies Cover & Gasket

Increased safety type / 
Rain-tight / 
Water-tight

Cl. I, Div. 1 & 2, Groups A, B, C, D / 
NEMA 3, 3X / 
Zone 1, Zone 2 / II 2G Ex e II IP 44

Dimensions

Hub Size

2 Way

Below

F7LB 16

F7LB 22

F7LB 28

F7LB 36

F7LB 42

F7LB 54

F7LB 70

F7LB 82

F7LB 104

F7LR 16

F7LR 22

F7LR 28

F7LR 36

F7LR 42

F7LR 54

F7LR 70

F7LR 82

F7LR 104

F7LL 16

F7LL 22

F7LL 28

F7LL 36

F7LL 42

F7LL 54

F7LL 70

F7LL 82

F7LL 104

F7LC 16

F7LC 22

F7LC 28

F7LC 36

F7LC 42

F7LC 54

F7LC 70

F7LC 82

F7LC 104

F7LT 16

F7LT 22

F7LT 28

F7LT 36

F7LT 42

F7LT 54

F7LT 70

F7LT 82

F7LT 104

F7LTB 16

F7LTB 22

F7LTB 28

F7LTB 36

F7LTB 42

F7LTB 54

F7LTB 70

F7LTB 82

F7LTB 104

F7LX 16

F7LX 22

F7LX 28

F7LX 36

F7LX 42

F7LX 54

F7LX 70

F7LX 82

F7LX 104

Right

Left

Continue

T type

T Below type

X type

3 Way

4 Way

Selection Table

1 / 2

3 / 4

1

1-1/4

1-1/2

2

2-1/2

3

4

A

97

111

127

142

154

180

229

235

279

35

40

45

56

62

76

108

108

133

38

42

48

60

66

81

92

118

138

137

151

173

190

204

230

293

299

351

75

80

84

104

112

126

172

172

247

55

60

68

80

87

101

140

140

169

58

62

71

84

91

106

124

150

174

102

114

129

141

150

170

218

216

298

117

131

150

166

179

205

261

267

316

35

42

52

60

66

81

92

118

226

15

17.5

21

25

29

35

43

51

65

29

35

42

50

58

70

86

102

130

81

97

114.5

127

138

162

213

213

260.5

24

29

35

45

49.5

62

90.5

90.5

114.5

140

156

172

190

204

230

293

299

382

55

62

72

84

91

106

124

150

263

35

40

44

56

62

76

108

108

175

55

60

64

80

87

101

140

140

211

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

R

S

T

Hub Size

1 / 2

3 / 4

1

1-1/4

1-1/2

2

2-1/2

3

4

(Dimensions in millimeters)

Conduit Outlet Bodies

Industrial Fittings

C

KEPIC-EN 

Certificate

Model Number Logic

Example 1) Conduit Outlet Bodies F7 Below turn NPT 28 F7LTB N28

Example 2) Conduit Outlet Bodies F7 3Way below turn PF 36 F7LTB P36

Hub threads
Spec.

N : NPT

threads

P : PF

threads

Select 
constant

F7L

Elbow type

B : Below turn
L : Left turn
R : Right turn
T : 3Way
TB : 3Way Below
C : Straight
X : 4Way

OO

O

Hub threads 
size

OO

Type LC

Type LB, LL, LR

Type LT, LTB, LX

catalog_eng-html.html
background image

Industrial Fittings

C28 _ C29

Industrial Fittings

C

Applications

Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing.
Connect and change direction of conduit run. Allow connections for branch runs.
Permit access to conductors for maintenance.

Features

High tensile strength and ductility. High corrosion-resistance, high impact and shock resistance.
Roomy interiors; more wiring space. No wire damage ; smooth, rounded integral bushing in each 
hub protects conductor insulation. Accurately tapped, threads for tight, rigid joints and ground continuity.
Applications and installation dimensions are also interchangeable.

Standard Materials

Bodies & Cover - Ductile or Cast Iron

Gasket – Neoprene or Rubber

Standard Finishes

Bodies & Covers – Hot Dip Galvanized or Electro Zinc Plate & Epoxy painted.

Threads – Oil touch up or Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment – General requirements

IEC 60079-7 Equipment protection by increased safety 

e

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

UL Standard: 514B

Size Ranges

1/2

to 2

F8 Series - Ex e II 

Conduit Outlet Bodies 

Cover & Gasket

Certification

Certified KOSHA (Korea Occupational Safety & Heal th Agency)

KEPIC-EN Certi. No. : EN - 335

Model Number Logic

Example 1) Conduit Outlet Bodies F8 Below turn 

NPT 28 F8LB N28

Example 2) Conduit Outlet Bodies F8 3Way below turn 

PF 36 F8LTB P36

Hub threads Spec.

N : NPT threads
P : PF threads

Select 
constant

F8L

Elbow type

B : Below turn
L : Left turn
R : Right turn
T : 3Way
TB : 3Way Below

OO

O

Hub threads 
size

OO

KEPIC-EN 

Certificate

Increased safety type /
Rain-tight / 
Water-tight

Cl. I, Div. 1 & 2, Groups A, B, C, D /
NEMA 3, 3X / 
Zone 1, Zone 2 / II 2G Ex e II IP 44

Dimensions

LT - Size

Dimension(MM)

L

W

H

A

D

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

150
165
200 
220 
250 
305 

60
65
75
85

100
130

44
46
57
66
70
90

110
130
150
170
200
255

32
38
45
54
62
75

(Dimensions in millimeters)

LT - Size

catalog_eng-html.html
background image

F8 Series - Ex e II 

Conduit Outlet Bodies 

Cover & Gasket

Dimensions

LL - Size

Dimension(MM)

L

W

H

A

D

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

130
150
175
195
225
280

60
65
50
60
70
95

36
46
57
60
70
90

110
130
150
170
200
255

32
46
45
54
62
75

LR - Size

Dimension(MM)

L

W

H

A

D

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

130
150
175
195
225
280

60
65
75
85

100
130

36
46
57
60
70
90

110
130
150
170
200
255

32
38
45
54
62
75

Conduit Outlet Bodies

Industrial Fittings

C

(Dimensions in millimeters)

(Dimensions in millimeters)

LL - Size

LR - Size

Increased safety type /
Rain-tight / 
Water-tight

Cl. I, Div. 1 & 2, Groups A, B, C, D /
NEMA 3, 3X / 
Zone 1, Zone 2 / II 2G Ex e II IP 44

LTB - Size

Dimension(MM)

L

W

H

A

D

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

150
165
200 
220 
250 
305 

40
45
50
60
70
95

63
66
80
66
70
90

110
130
150
170
200
225

32
38
45
54
62
75

(Dimensions in millimeters)

LTB - Size

LB - Size

Dimension(MM)

L

W

H

A

D

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

130
150
175
195
225
280

40
45
50
60
70
95

55
66
83
84

102
130

110
130
150
170
200
255

32
38
45
54
62
75

Selection Table

Hub Size

2 Way

3 Way

Below

Right

Left

T type

T Below type

1 / 2

3 / 4

1

1-1/4

1-1/2

2

F8LB 16

F8LB 22

F8LB 28

F8LB 36

F8LB 42

F8LB 54

F8LR 16

F8LR 22

F8LR 28

F8LR 36

F8LR 42

F8LR 54

F8LL 16

F8LL 22

F8LL 28

F8LL 36

F8LL 42

F8LL 54

F8LT 16

F8LT 22

F8LT 28

F8LT 36

F8LT 42

F8LT 54

F8LTB 16

F8LTB 22

F8LTB 28

F8LTB 36

F8LTB 42

F8LTB 54

(Dimensions in millimeters)

LB - Size

KEPIC-EN 

Certificate

catalog_eng-html.html
background image

Industrial Fittings

C30 _ C31

Industrial Fittings

C

Applications

Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing.
Connect and change direction of conduit run. Allow connections for branch runs. 
Permit access to conductors for maintenance. Large body size facilitates pulling of large and heav
y conductors. Specially designed raised cast covers provide additional wiring area.
Mogul for pulling straight, 45

°

or 90

°

angle turns an d/or making taps and splices.

Features

High tensile strength and ductility. High corrosion-resistance, high impact and shock resistance.
Roomy interiors; more wiring space. No wire damage; smooth, rounded integral bushing in each 
hub protects conductor insulation. Accurately tapped, threads for tight, rigid joints and
ground continuity. Completely interchangeable with Appleton Mogul Unilet Series. 
Applications and installation dimensions are also interchangeable.

Standard Materials

Bodies & Cover - Ductile or Cast Iron

Gasket – Neoprene or Rubber

1

to 4

Standard Finishes

Bodies & Covers – Hot Dip Galvanized or  Electro Zinc Plate & Epoxy painted.

Threads – Oil touch up or Electro Zinc Plated

Compliances / Approvals

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

UL Standard: 514B

NEC 6X – LB, LL, LR , NEC 8X – LT, LC

Size Ranges

MOGUL Series - Non Hazard.

Conduit Outlet Bodies Cover & Gasket

Certification

KEPIC-EN Certi. No. : EN - 335

Model Number Logic

Example 1) Conduit Outlet Bodies Mogul Below turn NPT 28 MOGUL LB N28

Example 2) Conduit Outlet Bodies Mogul 3Way PF 54 MOGUL LT P54

Hub threads
Spec.

N : NPT

threads

P : PF

threads

Select 
constant

MOGUL

Elbow type

B : Below turn
L : Left turn
R : Right turn
T : 3Way
TB : 3Way Below

OO

O

Hub threads 
size

OO

NEC 6X, 8X

KEPIC-EN 

Certificate

catalog_eng-html.html
background image

Conduit Outlet Bodies

Industrial Fittings

C

MOGUL Series - Non Hazard.

Conduit Outlet Bodies Cover & Gasket

Selection Table

Hub Size

2 Way

3 Way

Below

Right

Left

Continue

T ype

1 / 2

1-1 /2

2

3

4

MOGUL LB 28
MOGUL LB 42
MOGUL LB 54
MOGUL LB 82

MOGUL LB 104

MOGUL LR 28
MOGUL LR 42
MOGUL LR 54
MOGUL LR 82

MOGUL LL 28

MOGUL LL42

MOGUL LL 54
MOGUL LL 82

MOGUL LC 28
MOGUL LC 42
MOGUL LC 54
MOGUL LC 82

MOGUL LT 28
MOGUL LT 42
MOGUL LT 54
MOGUL LT 82

Dimensions

Bending Radius – LB type

1

1-1/2

2
3
1

1-1/2

2
3
1

1-1/2

2
3
1

1-1/2

2
3
4

249
354
456
682
249
354
456
682
227
330
371
570
227
330
371
535
699

70
95

113
151

70
95

113
151

70
95

152
153

92

133
160
254
318

60
79
79

117

60
79
79

117

60
79
79

125

60
79
79

149
178

48
64
64
92
48
64
64
92
48
64
64
97
48
64
64
89

117

168
237
330
533
168
264
359
564
168
264
300
419
168
237
273
432
584




83

105

105

152

82

105

105

164










83

200

295

328
475

200
295

329

470

619











48

60

68

137

178

24
35
41

5

24
35
41
55
24
34
41
55
24
35
41
64
83

62
86

102
138

62
86

102
138

62
86

116
134

62

100
124
130
162

48
65
81

111

48
65
81

111

48
65
87

111

48
78
87


Type

A

B

C

D

E

F

G

H

J

K

L

Hub Size

LC

LT

LL.LR

LB

(Dimensions in millimeters) 

NEC 6X, 8X

KEPIC-EN 
Certificate

Bending Radius of Type LB

(Dimensions in millimeters) 

Hub Size

R1

R2

1

1-1/2

2

3

4

41

67

76

127

159

67

105

127

203

260

Type LC, LT

Type LL, LR, LB 1”~ 2”

Type LB 3”~ 4”

LB Mogul 1”-2”

LB Mogul 1-2 / 2”-4”

catalog_eng-html.html
background image

Industrial Fittings

C32 _ C33

Industrial Fittings

C

Explosion-proof / 
Weather-tight
Weather-resistant / 
Wet location

Cl. I, Div. 1 & 2, Groups A, B, C, D / 
NEMA 3, 3R
Zone 1, Zone 2 /
II 2G Ex d II C

Applications

EU Series union couplings are installed in threaded thick-wall conduit systems:

- To change direction in threaded rigid conduit run by 90

°

, or when terminating at a box or fitting.

EUM – to connect conduit to a conduit fitting, junction box or device enclosure

EUF – to connect conduit to conduit, or to provide a means for future modification of the conduit system

EUAG 90 angle union couplings are installed in conduit run or in box or fitting hub:

Features

EUM, EUF and EUAG 90 union couplings have:

Compact design which permits assembly with a minimum of clearance to other adjacent conduit 

and / or equipment.

Strong and durable construction.

Standard Materials

EUM, EUF union couplings – Steel

EUAG 90 degrees – *Ductile or Cast Iron

Standard Finishes

Steel – Electro-galvanized with chromate treatment

Cast iron, Ductile – Hot Dip Galvanized or Electro Zinc Plate & Epoxy Painted

Thread – Oil touch up or Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment – General requirements 

IEC 60079-1 Equipment protection by flameproof enclosures

d

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

UL Standard: 886

EU Series - Ex d II C  

Union Couplings

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

KEPIC-EN Certi. No. : EN - 335

Model Number Logic

Example 1) Union Coupling Male type NPT 28 EUM N28

Example 2) Union Coupling Angle 90 type PF 54 EUAG90 P54

Hub threads
Spec.

N : NPT

threads

P : PF

threads

Select 
constant

EU

Coupling type

M : Male type
F : Female type
*AG90 : Angle 90

degree type

OO

O

Hub threads 
size

OO

1/2

to 4

– EUM & EUF

1/2

to 2

– EUAG 90

Size Ranges

Male or Female

Straight & 45 

degree & 90 
degree

KEPIC-EN 

Certificate

Union Couplings

Industrial Fittings

EUM

EUAG

EUF

catalog_eng-html.html
background image

Union Couplings

Industrial Fittings

C

Explosion-proof / 
Weather-tight
Weather-resistant / 
Wet location

Cl. I, Div. 1 & 2, Groups A, B, C, D / 
NEMA 3, 3R
Zone 1, Zone 2 /
II 2G Ex d II C

EU Series - Ex d II C  

Union Couplings

Selection Table

Hub Size

Male type

Female type

Angle 90 degree type

1 / 2”
3 / 4”

1”

1-1/4”
1-1/2”

2”

2-1/2”

3”
4”

EUM 16
EUM 22
EUM 28
EUM 36
EUM 42
EUM 54
EUM 70
EUM 82

EUM 104

EUF 16
EUF 22
EUF 28
EUF 36
EUF 42
EUF 54
EUF 70
EUF 82

EUF 104

EUAG90 16
EUAG90 22
EUAG90 28
EUAG90 36
EUAG90 42
EUAG90 54

-
-
-

Dimensions

EUM - Size

Dimension(MM)

A

Ø

B

C

Ø

D

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (2-1/2

)

#82 (3

)

#90 (3-1/2

)

#104 (4

)

#130 (5

)

#150 (6

)

35
41
51
61
67
79
95

110
121
136
170
197

38
44
54
64
70
82
99

113
125
139
161
186

36.5
41.5

46
47
53
56
67
70
73
76

77.2
74.7

14.5
19.5

25
33
39
51
62
77
89

102
127
153

EUAG90 - Size

Dimension(MM)

A

B

C

D

E

Ø

F

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

31
38

45.5

55

61.5

75

35
41

48.5

58

65.5

80

61.5
67.5

76
81
93

103

27.5
32.5

37
41
47
52

46.5
54.5

64
73

81.5
91.5

16

19.5

25
33
39
51

EUF - Size

Dimension(MM)

A

Ø

B

C

Ø

D

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (2-1/2

)

#82 (3

)

#90 (3-1/2

)

#104 (4

)

#130 (5

)

#150 (6

)

35
41
51
61
67
79
95

110
121
136
170
197

38
44
54
64
70
82
99

113
125
139
161
186

37.5
41.5

46
48
54
58
67
70
73
76
82
82

14.5
19.5

25
33
39
51
62
77
89

102
127
153

EUM - Size

EUF - Size

EUAG90 - Size

catalog_eng-html.html
background image

Industrial Fittings

C34 _ C35

Industrial Fittings

C

Plugs & Adapters, Sockets

Industrial Fittings

Explosion-proof / Rain-tight / 
Water-tight / Corrosion Resistant /
Submersible*

Cl. I, Div. 1 & 2, Groups A, B, C, D
NEMA 4, 4X / II 2G Ex d II C & 
Ex e II IP 66

Safety Instructions

The most important safety instructions are summarized in the section. 
They supplement. The corresponding regulations which the personnel in charge must study.
When working in hazardous areas, safety of the personnel and plant depends on complying with 
all relevant safety regulations. Assembly and maintenance staff working on installations 
therefore have particular responsibility. Precise knowledge of the applicable standards and 
regulations is required.
As the user, please note:

National safety and accident prevention regulations

National assembly and installation regulations

Generally recognized technical regulations

Safety instructions and information in these operating instructions

Characteristic values of the type labels and instruction plates

That any damage of the components may render the Ex-protection null and void. Use the 

component in accordance with its designated use and for its intended purpose only.

Incorrect or impermissible use or non-compliance with these instructions invalidates our 
warranty provision.
Any alterations and modifications to the component impairing its explosion protection are not permitted.
Install the component only if it is clean and undamaged.

EAG Series - Ex d II C  

EAG Adapters

ESG Series - Ex d II C  

ESG Sockets

FPG Series - Ex d II C  

FPG Stopping Plugs

Selection Table

Male Thread

Threads Per Inch

Pitch

Major Dia. (mm)

Size

M16

M20

M25

M32

M40

M50

M63

M75

1/2" NPT

3/4" NPT

1" NPT

1-1/4" NPT

1-1/2" NPT

2" NPT

2-1/2" NPT

3" NPT

3-1/3" NPT

4" NPT

1/2"PF

3/4"PF

1"PF

1/4"PF

1-1/2"PF

2"PF

2-1/2"PF

3"PF

3-1/2"PF

4"PF

Female Thread

16.93
16.93
16.93
16.93
16.93
16.93
16.93
16.93

14
14

11 1/2
11 1/2
11 1/2
11 1/2

8
8
8
8

14
14
14
11
11
11
11
11
11
11

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

1.81
1.81

2.2
2.2
2.2
2.2

3.175
3.175
3.175
3.175

1.81
1.81
1.81
2.31
2.31
2.31
2.31
2.31
2.31
2.31

16
20
25
32
40
50
63
75

21.34
26.67

33.4

42.16
48.26
60.33
73.03

88.9

101.6
114.3
20.95
22.91
26.44
33.25
41.91

47.8

59.61
75.18
87.88

113.03

M16
M20
M25
M32
M40
M50
M63
M75

1/2"NPT

3/4"NPT

1"NPT

1-1/4"NPT

1-1/2"NPT

2"NPT

2-1/2"NPT

3"NPT

3-1/2"NPT

4"NPT

1/2"PF

3/4"PF

1"PF

1-1/4"PF

1-1/2"PF

2"PF

2-1/2"PF

3"PF

3-1/2"PF

4"PF

Code

Thread Size

Metric

NPT

PF

1

2

3

4

5

6

7

8

9

M20

M25

M32

M40

M50

M63

M75

M90

M100

1/2"

3/4"

1"

1 1/4"

1 1/2"

2"

2 1/2"

3"

4"

1/2"

3/4"

1"

1 1/4"

1 1/2"

2"

2 1/2"

3"

4"

Adapters & Sockets

Stopping plugs

Sockets

Adapters

catalog_eng-html.html
background image

Plugs & Adapters, Sockets

Industrial Fittings

C

Explosion-proof / Rain-tight /
Water-tight / Corrosion Resistant /
Submersible*

Cl. I, Div. 1 & 2, Groups A, B, C, D
NEMA 4, 4X / II 2G Ex d II C & 
Ex e II IP 66

Application

A wide range of Thread Conversion Adapters and reducers for hazardous area applications. 
Used to connect cable entry devices and equipment having dissimilar threads.
Care should be taken to ensure that a suitable sealing gasket is also selected and installed where 
applicable, to ensure that an effective seal is made at the entry.

Materials

Adapter and Socket: Available in a variety of materials and finishes including Brass, Carbon Steel, 
Stainless Steel with optional nickel plating of brass components.
IP66 – Silicon

O

ring

Compliances / Approvals

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof enclosures 

d

IEC 60079-7 Equipment protection by increased safety 

e

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

BS 3643 ISO metric screw threads. Principles and basic data.

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

EAG Series - Ex d II C  

EAG Adapters

ESG Series - Ex d II C  

ESG Sockets

ESG (Socket)

EAG (Adapter)

Model Number Logic

Example 1) Adapter Male NPT 28 Female NPT16 EAG N28 N16

Example 2) Socket Male PF 36 Female NPT 22 IP68 ESG P36 N22 S

Model

EAG: 
Adapters
ESG: 
Sockets

EXG

Model threads Spec.

M : Metric threads
N : NPT threads
P : PF threads

O

Female 
threads Spec.

M : Metric threads
N : NPT threads
P : PF threads

O

Male threads Size

OO

Female threads size

OO

IP Grade

IP 66 : None
IP 68 : S

O

catalog_eng-html.html
background image

Industrial Fittings

C36 _ C37

Industrial Fittings

C

Dimensions

EAG (NPT) - Size

Dimension(MM)

A

B

L

L1

L2

#22 (3/4

) ~ #16 (1/2

)

#28 (1

) ~ #22 (3/4

)

#36 (1-1/4

) ~ #28 (1

)

#42 (1-1/2

) ~ #36 (1-1/4

)

#54 (2

) ~ #42 (1-1/2

)

#70 (2-1/2

) ~ #54 (2

)

#82 (3

) ~ #70 (2-1/2

)

#104 (4

) ~ #82( 3

)

33
40
51
61
72
89

105
140

30
36
46
55
65
80
95

127

18.9
22.4
24.0
24.4
25.3
34.9
40.5
43.0

5.0
5.0
6.0
6.0
6.0
6.0

10.0
10.0

13.6
13.9
17.4
18.0
18.4
19.3
28.9
30.5

ESG (NPT) – Size

Dimension(MM)

A

FEMALE

MALE

B

L

L1

L2

#22 (3/4

)

#16 (1/2

)

#28 (1

)

#22 (3/4

)

#36 (1-1/4

)

#28 (1

)

#42 (1-1/2

)

#36 (1-1/4

)

#54 (2

)

#42 (1-1/2

)

#70 (2-1/2

)

#54 (2

)

#82 (3

)

#70 (2-1/2

)

#104 (4

)

#82( 3

)

33
40
51
61
72
89

105
140

30
36
46
55
65
80
95

127

31.1
34.9
38.4
39.5
40.9
51.8
62.9
67.0

17.5
21.0
21.0
21.5
22.5
32.5
34.0
36.5

13.9
17.4
18.0
18.4
19.3
28.9
30.5
33.0

EAG (PF & Metric)-Size

Metric thread

Dimension(MM)

PF thread

A

B

L

L1

L2

M25 ~ M20
M32 ~ M25
M40 ~ M32
M50 ~ M40
M63 ~ M50
M75 ~ M63
M90 ~ M75
M100 ~ M90

#22 (3/4

)  ~ #16 (1/2

)

#28 (1

)   ~ #22 (3/4

)

#36 (1-1/4

)  ~ #28 (1

)

#42 (1-1/2

)  ~ #36 (1-1/4

)

#54 (2

)  ~ #42 (1-1/2

)

#70 (2-1/2

)  ~ #54 (2

)

#82 (3

)  ~ #70 (2-1/2

)

#104 (4

)  ~ #82 (3

)

33
40
51
61
72
89

105
140

30
36
46
55
65
80
95

127

23.0
28.0
29.0
29.0
29.0
29.0
35.0
46.0

5.0
5.0
6.0
6.0
6.0
6.0

10.0
10.0

19.0
24.0
24.0
24.0
24.0
24.0
28.0
38.0

ESG (PF & Metric)-Size

Metric thread

Dimension(MM)

PF thread

FEMALE MALE

FEMALE

MALE

A

B

L

L1

L2

M25

M20

M32

M25

M40

M32

M50

M40

M63

M50

M75

M63

M90

M75

M100 M90

#22 (3/4

)

#16 (1/2

)

#28 (1

)

#22 (3/4

)

#36 (1-1/4

) #28 (1

)

#42 (1-1/2

) #36 (1-1/4

)

#54 (2

)

#42 (1-1/2

)

#70 (2-1/2

) #54 (2

)

#82 (3

)

#70 (2-1/2

)

#104 (4

)

#82 (3

)

33
40
51
61
72
89

105
140

30
36
46
55
65
80
95

127

39.0
39.0
49.0
49.0
49.0
50.0
55.0
75.0

21.0
21.0
26.0
26.0
26.0
26.0
30.0
39.0

18.0
18.0
23.0
23.0
23.0
24.0
27.0
35.0

EAG (NPT) - Size

ESG (NPT) – Size

EAG (PF & Metric)-Size

ESG (PF & Metric)-Size

catalog_eng-html.html
background image

Plugs & Adapters, Sockets

Industrial Fittings

C

Plugs & Adapters, Sockets

Industrial Fittings

C

Explosion-proof / Rain-tight / Water-tight /
Corrosion Resistant / Submersible*

Cl. I, Div. 1 & 2, Groups A, B, C, D
NEMA 4, 4X / II 2G Ex d II C & 
Ex e II IP 66

Application

A comprehensive range of stopper plugs which are designed to close any unused entries in electrical 
equipment. In general care should be taken to ensure that a suitable entry thread sealing washer is 
also selected and installed, where applicable maintaining the integrity of the enclosure or equipment
I.P. rating.

Materials

Stopper Plug: Available in a Brass, *Aluminum, Carbon Steel, Stainless Steel. 
Optional nickel plating of brass components also available.
IP66 – Silicon

O

ring 

Compliances / Approvals

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof enclosures

d

IEC 60079-7 Equipment protection by increased safety

e

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

BS 3643 ISO metric screw threads. Principles and basic data.

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

FPG Series  

Stopping Plug

Model Number Logic

Example 1) Stopping plugs NPT 28 FPG N28

Example 2) Stopping plugs PF 36 IP68 FPG P36 S

Select 
constant

FPG

Special Material

a : Aluminum
None : others

O

Male threads size

OO

Male threads Spec.

M : Metric threads
N : NPT threads
P : PF threads

O

IP Grade

IP 66 : None
IP 68 : S

O

FPG (Stopper Plug)

FPGa (Stopper Plug)

Selection Table

Hub Size

Normal

Aluminum

#16 (1 / 2

)

#22 (3 / 4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (2-1/2

)

#82 (3

)

#104 (4

)

FPG 16
FPG 22
FPG 28
FPG 36
FPG 42
FPG 54
FPG 70
FPG 82

FPG 104

FPGa 16
FPGa 22
FPGa 28
FPGa 36
FPGa 42
FPGa 54

-
-
-

catalog_eng-html.html
background image

Industrial Fittings

C38 _ C39

Industrial Fittings

C

Dimensions

FPG (NPT)-Size

Dimension(MM)

A

B

L

L1

O-ring

#16 (1 / 2

)

#22 (3 / 4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (2-1/2

)

#82 (3

)

#104 (4

)

26
33
40
51
61
78
89

100
132

24
30
36
46
55
70
80

100
120

20.6
20.9
25.4
26.0
27.4
29.3
38.9
42.5
45.0

5.0
5.0
5.0
5.0
6.0
6.0
6.0
8.0
8.0

AN 018
AN 021
AN 123
AN 128
AN 132
AN 228
AN 232
AN 237
AN 245

EPGa (PF & NPT) - Size

Dimension(MM)

A

B

C

#16 (1 / 2

)

#22 (3 / 4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

15
15

19.5

19

19.5

19

20
22

26.5
27.5
26.5
25.5

29
31
39
50
59

67.5

FPG (PF &

*Metric)-Size

Dimension(MM)

A

B

L

L1

O-ring

#16 (1 / 2

)

#22 (3 / 4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (2-1/2

)

#82 (3

)

#104 (4

)

26
33
40
51
61
78
89

110
132

24
30
36
46
55
70
80

100
120

25.0
25.0
30.0
30.0
31.0
31.0
32.0
34.0
34.0

5.0
5.0
5.0
5.0
6.0
6.0
6.0
8.0
8.0

AN 018
AN 021
AN 123
AN 128

AN 132, *AN 134

AN 228,*AN 229

AN 232, *AN 233

AN 237

*AN 240, AN 244

FPG (NPT)-Size

FPG (PF & *Metric)-Size

EPGa (PF & NPT) - Size

catalog_eng-html.html
background image

Industrial Fittings

C

Nipples&Couplings,Normal Bends

Industrial Fittings

C

Weather-tight / 
Weather-resistant / 
Wet location

Cl. I, Div. 1 & 2, Groups A, B, C, D /
NEMA 3.3RX / II 2G Ex d II C & Ex e II

Application

FNG Series nipples are threaded by PF or NPT. FNG Series are used with rigid conduit for fittings, 
steel or aluminum. Outdoors or indoors use rain-boot fittings for :

Conduit systems expansion and alterations.

Maintenance and repair operations.

New, altered or damaged stub-ups.

Connections at panels and boxes.

Embedment in concrete. Installations in tight quarters : 
near corners, walls, ceilings, overhangs, obstacles or adjacent raceways.

Situations where threading equipment or heavy pipe wrenches are impractical.

Conduit systems in locations

Features

May be installed in any position.

Tough and durable, long lasting, trouble free in stallations.

Full line – 

¾”

to 6

Faster, easier method to install rain-tight rigid / raceway systems.

Materials

FNG Series nipples: Available in a variety of materials and finishes including Brass,
Carbon Steel, Stainless Steel with optional nickel plating of brass compnents.

Compliances / Approvals

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof enclosures

d

IEC 60079-7 Equipment protection by increased safety

e

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

BS 3643 ISO metric screw threads. Principlesand basic data.

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

FNG Series  

Nipples

FNG & FNGC Series-Ex d II C  

Hazardous Area Type

FNGS Series- Non Hazard.  

Non- hazardous Area Type

Model Number Logic

Example 1) Nipple NPT 28 FNG N28

Example 2) Chase nipples PF 36 FNGS P36

Threads Spec.

N : NPT

threads

P : PF

threads

Select 
constant

FNG

Model None

C : Closed nipples
*S : Chase nipples

O

O

Threads 
size

OO

FNG

FNGC

FNGS

catalog_eng-html.html
background image

Industrial Fittings

C40 _ C41

Industrial Fittings

C

Dimensions

FNG - Size

Dimension(MM)

D

d

L

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (1-1/2

)

#82 (3

)

#104 (4

)

21.0
26.5
33.3
41.9
47.8
59.6
75.2
87.9

113.4

16.4
21.9
28.3
36.9
42.8

54

69.6
82.3

106.4

44
44
55
55
55
65
65
80
90

FNGS - Size

Dimension(MM)

A

E

F

L

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (1-1/2

)

#82 (3

)

#104 (4

)

14
19
25
33
39
51
62
77

102

24
30
35
46
50
62
78
90

115.5

26
33
38
49
53

64.5

82
94

119.5

23
23
27
28
33
35
38
41
41

FNGC - Size

Dimension(MM)

D

d

L

#22 (3/4

)

#28 (1

)

#42 (1-1/2

)

#54 (2

)

#82 (3

)

#104 (4

)

#130 (5

)

#150 (6

)

26.5
33.3
47.8
59.6
87.9

113.4
141.3
168.3

21.9
28.3
42.8
54.0
82.3

106.4
128.9
154.8

43.2
50.8
56.0
56.0
88.4
91.0
96.5

102.0

Selection Table

Hub Size

Normal

Closed nipples

Chase nipples

#16 (1 / 2

)

#22 (3 / 4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (2-1/2

)

#82 (3

)

#104 (4

)

#130 (5

)

#150 (6

)

FNG 16
FNG 22
FNG 28
FNG 36
FNG 42
FNG 54
FNG 70
FNG 82

FNG 104


FNGC 22
FNGC 28

FNGC 42
FNGC 54
FNGC 70
FNGC 82

FNGC 104
FNGC 130
FNGC 150

FNGS 16
FNGS 22
FNGS 28
FNGS 36
FNGS 42
FNGS 54
FNGS 70
FNGS 82

FNGS 104


FNG - Size

FNGS - Size

FNGC - Size

catalog_eng-html.html
background image

Nipples&Couplings,Normal Bends

Industrial Fittings

C

Weather-tight / 
Weather-resistant /
Wet location

Cl. I, Div. 1 & 2, Groups A, B, C, D /
NEMA 3.3RX / II 2G Ex d II C & Ex e II

Application

Conduit systems expansion and alterations.

Maintenance and repair operations.

New, altered or damaged stub-ups.

Connections at panels and boxes.

Embedment in concrete. Installations in tight quarters: 
near corners, walls, ceilings, overhangs, obstacles or adjacent raceways.

Situations where threading equipment or heavy pipe wrenches are impractical.

Conduit systems in locations.

SVC couplings are threaded by PF or NPT. SVC couplings are used with rigid conduit for fittings, 
steel or aluminum. Outdoors or indoors use rain-boot fittingsfor:

Features

May be installed in any position.

Tough and durable, long lasting, trouble free in stallations.

Full line – 1 / 2

to 6

Faster, easier method to install rain-tight rigid/raceway systems.

Materials

SVC couplings : Available in a variety of materials and finishes including Carbon Steel, Stainless Steel .

Compliances / Approvals

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof enclosures 

d

IEC 60079-7 Equipment protection by increased safety

e

IEC 60529 Degree of protection provided by enclosures (IP Code)

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

BS 3643 ISO metric screw threads. Principlesand basic data.

Certification

Certified KOSHA (Korea occupational Safety & Health Agency)

SVC Series – Ex d II C  

SVC Couplings

SVC - Size

Dimension(MM)

Ø

A

L

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (2-1/2

)

#82 (3

)

#104 (4

)

#130 (5

)

#150 (6

)

24.0
31.0
37.5
47.0
54.0
66.0
83.0
95.0

119.0
153.0
180.0

38.0
44.0
50.0
56.0
56.0
64.0
72.0
80.0
90.0

100.0
100.0

Dimensions

Model Number Logic

Hub threads Spec.

N : Metric threads
P : NPT threads

Example 1) Coupling PF 36 SVC P36

Hub threads 
size

Series 
Constant

O

SVC

OO

catalog_eng-html.html
background image

Industrial Fittings

C42 _ C43

Industrial Fittings

C

Application

SNB Series are used in conjunction with rigid couplings to make a 45

°

or 90

°

bend between 

two lengths of threaded rigid conduit.

Features

Curvature of the conduit is used to fit specific locations and/or make turns or change 

directions in the installation.

Can be used in both indoor and outdoor applications, offering the customer increased flexibility.

Made of steel and galvanized for corrosion resistance.

Standard Materials

Steel

Standard Finishes

Hot Dip Galvanized

SNB Series – Non Hazard.   

Rigid Elbows

Dimensions

SNB45 & 90 - Size

Dimension(MM)

A

B

L

R

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

#70 (2-1/2

)

#82 (3

)

#104 (4

)

#130 (5

)

#150 (6

)

19
22
25
28
28
32
36
40
45
45
50

49
57
59
59
61
80

112
156
193
230
246

150
180
215
250
295
345
425
510
645
800
930

90

110
140
170
210
235
275
310
395
500
600

SNB90

SNB45

catalog_eng-html.html
background image

Bushings

Industrial Fittings

C

Application

Conduit systems expansion and alterations.

Maintenance and repair operations.

New, altered or damaged stubups.

Connections at panels and boxes.

Embedment in concrete.

Installations in tight quarters: 

near corners, walls, ceilings, overhangs, obstacles or adjacent raceways.

Situations where threading equipment or heavy pipe wrenches are impractical.

Conduit systems in locations.

FB Series are used with rigid conduit for fittings.

Features

May be installed in any position.

Tough and durable, long lasting, trouble free in stallations.

Faster, easier method to install rain-tight rigid / raceway systems.

Standard Materials

Body – Malleable iron

Insulator – Polyamide PA

Grounding lug – Copper

Bolt – Stainless Steel

Compliances / Approvals

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

UL Standard: 514B

KS C 8460

Certification

KEPIC-EN Certi. No. : EN-335

Size Ranges

Hub – 1/2

to 4

Finishes

Bodies -Hot Dip Galvanized or Electro Zinc Plate & Epoxy Painted

Threads – Oil touch up or Electro Zinc Plated

FB Series – Non Hazard.  

Bushings (Malleable Iron)

250

Rated 

Insulator

KEPIC EN  Certificate

UL514B & KS C 8460

Model Number Logic

Example 1) Bushing Non-insulated normal NPT 28 FB N28

Example 2) Bushing Insulated Grounding type PF 36 FBIE P36

Select 
constant

FB

Elbow Type

None : normal
I : insulated

O

Threads Spec.

N : NPT threads
P : PF threads

O

Grounding Spec.

Non : normal
E : Grounding

O

Threads Spec.

OO

FB

FBI

FBIE

catalog_eng-html.html
background image

Industrial Fittings

C44 _ C45

Industrial Fittings

C

Application

Conduit systems expansion and alterations.

Maintenance and repair operations.

New, altered or damaged stubups.

Connections at panels and boxes.

Embedment in concrete.

Installations in tight quarters: 
near corners, walls, ceilings, overhangs, obstacles or adjacent raceways.

Situations where threading equipment or heavy pipe wrenches are impractical.

Conduit systems in locations.

ZB Series are used with rigid conduit for fittings.

Features

May be installed in any position.

Tough and durable, long lasting, trouble free in stallations.

Faster, easier method to install rain-tight rigid / raceway systems.

Standard Materials

Body – Zinc Die Casting

Insulator – Polyamide PA

Compliances / Approvals

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

KS C 8460

Size Ranges

Hub – 1/2

to 4

Finishes

Bodies – Natural or Electro Zinc Plate

ZB Series – Non Hazard.  

Bushings (Zinc Die Casting)

250

Rated 

Insulator

KS C 8460

Model Number Logic

Example 1) Bushing Non-insulated NPT 28 ZB N28

Example 2) Bushing Insulated type PF 36 ZBI P36

Threads Spec.

N : NPT

threads

P : PF

threads

Select 
constant

ZB

Elbow type

None : normal
I : insulated

O

O

Threads 
size

OO

ZB

Zinc Bushing

Insulated zinc 
bushing 

Insulated grounding 
zinc bushing

ZBI

ZBIE

catalog_eng-html.html
background image

Industrial Fitting

Industrial Fittings

C

Bushings

Industrial Fittings

C

Application

At least one breather should be used with each drain.

EPD 16 as a breather function is installed in top of enclosure or upper section of conduit system.

EPD 16 as a drain function is installed in bottom of enclosure or in lower section of Conduit system.

Universal

is function as a breather when mounted at the top of an enclosure, or as a drain when 

mounted in the bottom of an enclosure.

Drains and breathers are installed in hubs or drilled and tapped openings.

EPD 16 drain and breather are installed in enclosures or conduit systems to:

Standard Materials

Stainless Steel with brass flots

Features

Capability to pass 50 cc of water per minute and 0.2 cubic feet or air per minute at at mospheric pressure.

EPD 16 each have a well inside the inner, threaded end to provide for accumulation of sediment without 
clogging when used as a drain.

EPD 16

Universal

drains and breathers have:

Notes

At least 5 full threads of drain or breather 

must be engaged in matching female thread.

EPD 16 can be factory installed on various 

explosion-proof quipment.

Typical installation of drain and breather

Compliances

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof 

enclosures 

d

ISO 228/1 Pipe threads where pressure- tight joints 

are not made on the threads

NEC 500

NEMA 4, 4X

IEC 60529

Size Ranges

BSPP Threads #16 (1/2

)

EPD16 / UAE 16 -Ex d II C  

For Automatic Water Drainage and Continuous Ventilation.

Explosion-proof / 
Rain-tight /
Water-tight / 
Corrosion Resistant

Cl. I, Div. 1 & 2 / 
Groups A, B, C, D / 
NEMA 4, 4X /
II 2G Ex d II C IP 65 /

EPD 16

Drains & Breather

UAB16

Drains & Breather

Application

At least one breather should be used with each drain.

UAB 16 as a breather function is installed in top of enclosure or upper section of conduit system.

UAB 16 as a drain function is installed in bottom of enclosure or in lower section of Conduit system.

Universal

is function as a breather when mounted at the top of an enclosure, or as a drain when

mounted in the bottom of an enclosure.

Drains and breathers are installed in hubs or drilled and tapped openings.

UAB 16 drain and breather are installed in enclosures or conduit systems to:

Standard Materials

Stainless Steel

Features

Show how water, which enters through end washer slots, spirals down the stud

s single lead thread 

and flows out the bottom.

Capability to pass 50 cc of water per minute and 0.2 cubic feet or air per minute at atmospheric pressure.

UAB 16 each have a well inside the inner, threaded end to provide for accumulation of sediment without 

clogging when used as a drain.

UAB 16 

Universal

drains and breathers have:

Notes

At least 5 full threads of drain or breather

must be engaged in matching female thread

UAB 16 can be factory installed on various 

explosion-proof equipment.

Typical installation of drain and breather

Compliances

IEC 60079-0 Equipment – General requirements

IEC 60079-1 Equipment protection by flameproof 

enclosures 

d

ISO 228/1 Pipe threads where pressure- tight joints 

are not made on the threads

NEC 500

NEMA 4, 4X

IEC 60529

Size Ranges

BSPP Threads #16 (1/2

)

catalog_eng-html.html
background image

Industrial Fittings

C46 _ C47

Industrial Fittings

C

Application

Act as pull box for conductors

Provide openings and space for making splices and taps in conductors

Provide for branch conduit runs

Provide access to conductors for maintenance and future system changes

Enclose and protect electrical devices

Where a heavy duty dustproof, weatherproof enclosure is desired, boxes are installed in conduit system to:

Standard Materials

Body – Steel

Gasket – Neoprene or Rubber

Bolt – Electro Zinc Plated Carbon Steel

Features

Flat neoprene or rubber cover gasket.

Wide range of drilled and tapped and slip hole conduit entrance sizes and locations permits extreme 

flexibility of use in conduit system.

Internal equipment mounting pads available blind tapped mounting screws.

Blind tapped into internal mounting pads.

Finishes

Bodies -Hot Dip Galvanized

SJB Series – Non Hazard.  

Steel Junction Boxes

Hot Dip Galvanized

Heavy Duty

Surface Mounting

Dimensions

CAT.NO.

DIMENSIONS(MM)

DIMENSIONS(MM)

WIDTH

HEIGHT

DEPT

CAT.NO.

WIDTH

HEIGHT

DEPT

SJB – 1

SJB – 2

SJB – 3

SJB – 4

SJB – 5

SJB – 6

SJB – 7

SJB – 8

SJB – 9

SJB – 10

SJB – 11

SJB – 12

SJB – 13

SJB – 14

SJB – 15

SJB – 16

SJB – 17

SJB – 18

SJB – 19

SJB – 20

SJB – 21

SJB – 22

100

100

100

150

150

200

200

200

250

250

250

300

300

300

300

400

400

400

500

500

600

600

300

300

300

300

400

400

400

500

500

600

600

100

150

200

300

150

200

300

200

300

300

400

100

100

100

150

150

200

200

200

250

250

250

50

75

100

100

150

100

150

200

100

150

200

Junction Boxes

Industrial Fittings

catalog_eng-html.html
background image

Industrial Fittings

C

Junction Boxes

Industrial Fittings

C

Gang Outlet Boxes&Covers

Steel Utility Boxes&Covers

Commercial or

Residential Ceiling
Boxes

For Use with Conduits

GANG

EXTENSION BOX

SURFACE COVER

FLAT COVER

Square Outlet Boxes&Covers

SQUARE BOX

EXTENSION BOX

SURFACE COVER

FLAT COVER

Octagon Outlet Boxes&Covers

OCTAGON BOX

EXTENSION BOX

SURFACE COVER

FLAT COVER

catalog_eng-html.html
background image

Industrial Fittings

C48 _ C49

Industrial Fittings

C

Receptacles Boxes

Water-Tight Surface Mounting Switches & Receptacles Boxes

Water-Tight Surface Mounting Receptacles Boxes

Diecasting Aluminum

Construction for Long
Product Life

For Use with Conduits

2P 15A 110Vac 2 GANGS

2P 15A 110Vac 4 GANGS

2P 15A 110Vac 6 GANGS

2P 15A 220Vac 1 GANG

2P 15A 220Vac 2 GANGS

2P 15A 220Vac 3 GANGS

2P 15A 300Vac

3P 30A 300Vac OR 3P 50A 300Vac

4P 30A 300Vac

catalog_eng-html.html
background image

Industrial Fittings

C

Junction Boxes

Industrial Fittings

C

General Use Snap Switches

Water-Tight Surface Mounting General Use Snap Switches

Die casting aluminum

construction for long
product life

For use with conduits

1P 3A 300Vac 1 GANG OR 

3P 6A 300Vac

1P 3A 300Vac OR 2 GANG  

3P 6A 300Vac

1P 6A 300Vac OR 3 GANG  

3P 6A 300Vac

Surface Mounting Box

Die casting aluminum

construction for long
product life

For use with conduits

DEAD END SURFACE 

MOUNTING SWITCH BOX

4-WAY OUTLET BOX

catalog_eng-html.html
background image

Industrial Fittings

C50_ C51

Industrial Fittings

C

MEMO

catalog_eng-html.html
background image

Excellent Quality Verified by Global Standards

Samwha's cable glands, as gualified with the IECEx and ATEX scheme certificates, 

are the products verified for quality. Our products provide the advanced solution to install 

any type of electrical wire.

catalog_eng-html.html
background image

Smart  +  Technolgy  +  Human

Contents

D

D

Cable Glands

Cable Glands

Industrial Cable Gland

Industrial & Hazardous Area Cable Gland 
Technical Description
CGK Un-armoured, Outer Sheath Seal  
CGK Industrial Cable Gland 
CGC Un-armoured, Outer Sheath Seal  
CGC Industrial Cable Gland 
A2 Un-armoured, Outer Sheath Seal  A2 Industrial Cable Gland 
BW Armoured, None Seal  BW Industrial Cable Gland
CW Armoured, Outer Sheath  CW Industrial Cable Gland 
CX Armoured, Outer Sheath Seal  CX Industrial Cable Gland
CXT Armoured, Outer Sheath Seal  CXT Industrial Cable Gland 
E1W Armoured, Outer & Inner Sheath Seal  
E1W Industrial Cable Gland 
E1X Armoured, Outer & Inner Sheath Seal  
E1X Industrial Cable Gland 
E2W Armoured, Outer & Inner Sheath Seal, Lead Sheath  
E2W Industrial Cable Gland 
BCW Armoured  BCW Industrial Cable Gland

Hazardous Area Type Cable Gland

ECG Un-armoured, Outer Sheath Seal, Ex d & Ex e”
ECG Flame-proof Ex d & Increased Safety Ex e Cable Gland
ECG-CB Un-armoured, Outer Sheath Seal, “Ex d & Ex e”
ECG-CB Flame-proof Ex d & Increased Safety Ex e Cable Gland
EGB Un-armoured, Outer Sheath Seal, “Ex d” 
EGB Flame-proof Ex d Cable Gland
EGC Un-armoured, Outer Sheath Seal, “Ex d”  
EGC Flame-proof Ex d Cable Gland
MCG Un-armoured, Outer Sheath Seal, “Ex d” MCG Multi Core
Custom Build Flame-proof Ex d Cable Gland 
A2F Un-armoured, Outer Sheath Seal, “Ex d & Ex e”
A2F Flame-proof Ex d & Increased Safety Ex e Cable Gland
CWe Armoured, Outer Sheath Seal, “Ex e” 
CWe Increased Safety Ex e Cable Gland
CXe Armoured, Outer Sheath Seal, “Ex e” 
CXe Increased Safety Ex e Cable Gland
E1FW Armoured, Outer & Inner Sheath Seal, “Ex d & Ex e”
E1FW Flame-proof Ex d & Increased Safety Ex e Cable Gland
E1FX Armoured, Outer & Inner Sheath Seal “Ex d & Ex e”
E1FX Flame-proof Ex d & Increased Safety Ex e Cable Gland
E2FW Armoured, Outer & Inner Sheath Seal, Lead Sheath “Ex d & 
Ex e” E2FW Flame-proof Ex d & Increased Safety Ex e Cable Gland
SS2K Un-armoured, Outer & Inner Sheath Seal “Ex d & Ex e”
SS2K Flame-proof Ex d & Increased Safety Ex e Cable Gland

Accessories

Earth Tags
Entry Thread Seal
Lock-Nuts
Shroud

D2

D8

D9

D10
D11
D12
D13
D14
D15

D16

D17

D18

D19

D20

D21

D22

D23

D25

D26

D27

D28

D29

D30

D31

D32
D32
D33
D33

catalog_eng-html.html
background image

Main Function of The Cable Gland

Cable Glands may provide environmental protection by sealing on the outer cable sheath, excluding 

dust and moisture from the electrical or instrument enclosure.

Cable Glands may facilitate earth continuity in the case of armoured cables, when the cable gland has a 

metallic construction.

Cable Glands may provide a holding force on the cable to ensure adequate levels of cable pull out 

resistance.

Cable Glands may provide additional sealing on the part of the cable entering the enclosure, when a high 

degree of ingress protection is required.

Cable Glands may provide additional environmental sealing at the cable entry point, maintaining the 

ingress protection rating of the enclosure with the selection of applicable accessories dedicated to
performing this function.

When used in hazardous areas they are required to maintain the level of protection of the equipment to 

which they are attached

Construction & Performance Standards

The original goal was later met by the British Standard 

BS 4121

, when the industry had developed further and with

more sophistication. Latterly in the 1970’s 

BS 4121

was superseded by 

BS 6121

with the introduction of the metric

system of measurement across Europe.
Although it does not replace the full scope of the 

BS 6121

construction requirements, today there is a European

Standard 

EN 50262

, which offers manufacturers the opportunity of meeting its requirements by degrees of

performance. It should be noted that whilst products that have been designed to comply with 

BS 6121

will quite

comfortably meet the requirements of 

EN 50262

, it does not automatically follow that cable glands designed to 

EN

50262

would also be able to comply with the requirements of 

BS 6121

.

Materials

Brass Extruded bar

EN12168 :1998 Grade CuZn39Pb (CW614N) (Previously BS2874:1986)

Stainless Steel

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1:1991)

Mild Steel

BS970 Part 1 : 1996 Grade 220MO7Pb

Thread Construction Standards

Metric

ISO 965-1, ISO 965-3 medium fit (6g) for external threads

NPT

ANSI / ASME B1.20.1 - 1983 guaging to clause 8.1 for external threads

BSPP

BS 2779 : 1986 (1973) class A full form for external threads

PG

DIN 40430:1971

ISO Metric IEC 60423

Industrial & Hazardous Area Cable Gland 

Technical Description

16

M16
1.5

16.93

15.93

16.5

20

M20
1.5

16.93

19.97

20.5

25

M25
1.5

16.93

24.97

25.5

32

M32
1.5

16.93

31.97

32.5

40

M40
1.5

16.93

39.97

40.5

50

M50
1.5

16.93

49.97

50.5

63

M63
1.5

16.93

62.97

63.5

75

M75
1.5

16.93

74.97

75.5

THREAD
REFERENCE

THREAD
PER INCH

MAJOR
DIAMETER MAX

CLEARANCE
HOLE Ø MAX

THREAD SIZE
THREAD PITCH

NPT Ansi B1.20.1

050

½”

1.81

14

21.34

21.84

075

¾

1.81

14

26.67

27.17

100

1”
2.20

11.5

33.4

33.9

125

1-1/4”
2.20

11.5

42.16

42.66

150

1-1/2”
2.20

11.5

48.26

48.76

200

2”
2.20

11.5

60.33

60.83

250

2-1/2”
3.18

8

73.03

73.53

300

3”
3.18

8

88.9

89.4

THREAD
REFERENCE

THREAD
PER INCH

MAJOR
DIAMETER MAX

CLEARANCE
HOLE Ø MAX

THREAD SIZE
THREAD PITCH

D

Industrial Cable Gland

Cable Glands

catalog_eng-html.html
background image

Crucial Cable Care

Two factors which could affect the long term cable performance are the type and design of the cable gland
sealing function, and the possibility of this being inadvertently, or otherwise, over tightened onto the cable
sheath.
In some applications it may be necessary to provide some mechanical protection to prevent the cables
from being damaged or completely severed by accidental encroachment of machinery or other major
impact.
This mechanical protection may be provided in the shape of a metallic conduit that can house individual
insulated cable conductors or a normal unarmoured sheathed cable. Alternatively a metallic sheath or
armour included in the cable construction during its manufacturing process may be used.
When cables with a protective metallic sheath or armour are chosen, these may be constructed with or
without an extruded inner bedding, underneath the layer of armouring. In some cases this extruded
bedding may be substituted by a polymeric covering or tube that contains the insulated conductors.
Cable glands for armoured cables, with a single outer seal should be selected for cables without an inner
bedding or covering under the armour. Cable glands for armoured cables, with a double, inner & outer,
seal configura tion would normally be selected for cables with an inner bedding or covering under the
armour.

PF BS2779

Construction of Seal Types

In general there are three different types of sealing methods used on the cable inner bedding, which are
a. Compression Seal       b. Displacement Seal       c. Compound Barrier Seal.

a. Compression Seal (Sealing Ring)

The Compression Seal is an elastomeric sealing ring that has a V groove or weak back in its design that is intended to

be closed in order to create a downward seal on the cable inner bedding, when the same compressive force is equally 

applied to both sides of the seal.

b. Displacement Seal (Sealing Ring)

The Displacement Seal does not employ a weak back design. Instead the Displacement Seal is gradually pushed down

a taper until it makes an effective seal on the cable.

c. Compound Barrier Seal (Epoxy Resin Compound)

The compound barrier seal is made on site by the technician 

completing the installation and is used primarily in hazardous
areas where the inner cable bedding must be removed and a 
hard setting resin barrier seal that has been specially tested 
for use in potentially explosive atmospheres is applied around 
the conductors.

050

½”

1.81

14

20.96

21.46

075

¾

1.81

14

26.44

26.94

100

1”
2.20

11

33.25

33.75

125

1-1/4”
2.20

11

41.91

42.41

150

1-1/2”
2.20

11

47.8

48.3

200

2”
2.20

11

59.61

60.11

250

2-1/2”
3.18

8

75.18

75.68

300

3”
3.18

8

87.88

88.39

THREAD
REFERENCE

THREAD
PER INCH

MAJOR
DIAMETER MAX

CLEARANCE
HOLE Ø MAX

THREAD SIZE
THREAD PITCH

PG DIN 40430

PG7

PG7
1.27

20

12.5

13

PG9

PG9
1.41

18

15.2

15.7

PG11

PG11
1.41

18

18.6

19.1

PG13.5

PG13.5
1.41

18

20.4

20.9

PG16

PG16
1.41

18

22.5

23

PG21

PG21
1.59

16

28.3

28.8

PG29

PG29
1.59

16

37

37.5

PG36

PG36
1.59

16

47

47.5

THREAD
REFERENCE

THREAD
PER INCH

MAJOR
DIAMETER MAX

CLEARANCE
HOLE Ø MAX

THREAD SIZE
THREAD PITCH

i. Compression Seal

iii. Sealing Compound Flameproof Barrier

ii. Displacement Seal

Cable Glands

D2 _ D3

Cable Glands

D

catalog_eng-html.html
background image

Selection of Cables Intended for Use in Hazardous Areas

Cables come in a wide variety of shapes and sizes and new designs, e.g. those with optical fibers, are
regularly being introduced. The issue of correctly sealing these cables as they enter hazardous area
electrical equipment is a worldwide problem, and not confined purely to local conditions in any one
particular place.
Selection of Cable Glands for Hazardous Areas Under IEC and CENELEC standards three main types of
cable glands exist for hazardous area applications for two different generic types of cables, these being
armoured and non armoured cables. These are summarized as follows.

Although there are no IEC construction standards for the cables intended for use in flammable
Atmospheres, according to IEC 60079- 14:2002, 10.4.2 (b), if a cable gland with an elastomeric flameproof
sealing ring is to be used, when connecting cables to Ex d equipment enclosures, the cable should be : 

Effectively, the cable should be physically assessed, taking into account the protection method and
configuration of the equipment, to verify its suitability, before any cable gland with an elastomeric sealing
ring can be selected.

Until such times when an IEC standard for cables for use in Hazardous Areas has been developed and
implemented, this applies to all types of cables used in flammable atmospheres, including.

Substantially compact and circular (i.e. especially the part of the cable entering the enclosure),

Typical IEC Cable Types

Impact Strength - 7 Nm Minimum

Minimum I.P. Rating - IP54 Gas / Vapour - IP64 Dust

Single (Outer) Seal as a Minimum 

Trend is to use Double (Inner/Outer) Seal

Minimum Requirements for Ex e Cable Glands

Screwed Entry Threads Must Maintain FLP Path 

Inner Seal Must Gas Tight and Maintain Explosion Protection category Ex d 

Trend is to use Dual Certified Ex d & Ex e

Minimum Requirements for Ex e Cable Glands

Where circumstances require Cable Glands of the Compound Barrier type to be selected instead of those
utillising an elastomeric seal. The following pages describes under what conditions a Compound Barrier
Gland should be used. In summary with good engineering practice prevailing, the use of Barrier Glands is
generally advised in the following circumstances 

Requirements for The Use of Ex d Compound Barrier Type Cable Glands

Cable used is not round, extruded bedded and suitably filled

The enclosure contains an internal ignition source, is approved for Zone 1 use and the internal free 

volume exceeds 2 liters

There is a risk of gas migration via the cable from a hazardous area to a safe area, or in transition of 
zones.

When Cables Directly Enter Flameproof Type ‘d' Equipment and ;

Have an extruded bedding (without any gaps),

Have fillers, if any are used, which are Non-Hygroscopic ?

Industrial & Hazardous Area Cable Gland 

Technical Description

INCREASED SAFETY - Ex e
FLAMEPROOF - Ex d
FLAMEPROOF COMPOUND BARRIER - Ex d

ARMOURED CABLES

NON-ARMOURED CABLES

Armoured

Unarmoured

Wire Braid Amour

Singe Wire Armour(SWA)

Steel Tape Armour(STA)

Normal Unarmoured

D

Industrial Cable Gland

Cable Glands

catalog_eng-html.html
background image

Cable Construction - Should Be Round

In order to comply with IEC installation standards, cable glands using elastomeric sealing rings as a
means of maintaining the Flameproof protection method can only be used if the cable selected is :-
"Substantially compact and circular with an extruded bedding, and if any fillers are used they are Non-
Hygroscopic“

-

This is clearly not always the case with cables used in hazardous areas.

-

But the cable must play a part in the safety of the installation, even in the case of indirect cable entry, 

when gas migration must be avoided.

-

e.g., where cables run across two zones, or indeed from a hazardous area into a safe area.

Two situations can be considered, direct cable entry and indirect cable entry.

Cable Entries Into Ex d Enclosures

Sample IEC Cable Configurations

Which type is suitable for use with Flameproof Ex d equipment when a cable gland with an elastomeric
sealing ring would be considered?

Cable A is not suitable to apply a Flameproof sealing ring as this cable is the incorrect shape, and unless

the cable is round the sealing ring will not be able to make an effective seal on the cable.

Cables B, D & E are not suitable to apply a Flameproof sealing ring, as the white areas represent a gap

or void in the cable whereby there is either no inner cable sheath, or extruded bedding, or suitable fillers
are absent. In this case no protection to the interstices of the cable can be offered by a sealing ring.

Cable C is the only one of the five sample cables illustrated which could be selected as correctly
meeting the IEC 60079-14 criteria, as it has an extruded inner cable bedding and there is no gas

migration path between the conductors.

Equally, if the cable is not adequately filled, and allows the passage of air or gas to flow along the cable

length then there would be no protection to the inner part of the cable when an elastomeric sealing ring

is used. In this case a compound barrier type cable gland is the only safe solution and this is needed to

maintain the integrity of the equipment as explained above, and prevent gas migration from equipment

to equipment, or hazardous areas to safe areas.

Direct Cable Entry - Ex d

Cable A

Cable B

Cable C

Cable D

Cable E

Indirect Cable Entry - Ex d

Cable Glands

D4 _ D5

Cable Glands

D

catalog_eng-html.html
background image

BS 6121 Definitions

Below are tables composed from data included in BS 6121: Part 1 : 1989

Cable Gland Material Selection

With the help of several independently accredited laboratories SAMWHA Products has carried out
extensive testing of materials for cable glands to be used in hostile environments, particularly with regards
to the mating of dis-similar metals. Together with the results of detailed research and the findings of this
bespoke testing, SAMWHA Products has been able to select the most suitable material for cable glands to
suit a wide variety of environmental applications including: 

Recognizing that the specific conditions of any installation will play a major part in the selection of the most
suitable cable gland material and taking into account the level of environmental exposure along with the
nature of the enclosure and cable armour material the following tables are offered as a general guide to
operations under normal conditions. Subject to there being no adverse environmental conditions prevailing
these tables can be used on a regular basis to determine the cable gland material recommended for
several different situations. 
Cable gland material selection is shown in Table 1.

Cable Gland Type Designations for Unarmoured Cables

-

Hostile salt water marine (offshore) situations, 

-

Dust and salt laden (coastal) atmospheres,

-

High and low temperature extremes, 

-

Ultra Violet (UV) degradation,

-

EMI/RFI pollution via electromagnetic interference,

-

Metallurgical corrosion caused by chemical attack and liquid,

-

Acid and vapourised pollutants, and 

-

The chemical agents used in industrial cleaning processes such as the wash or hose down operations in 

the offshore drilling industry.

(Requirements of EN 50262 ) 

-

is shown in Table 2

Electrical Properties-Protective Connection to Earth (Category A, B OR C)

-

Is shown in Table 2

The Short Circuit Fault Current Rating Values for Earth Tags

Industrial & Hazardous Area Cable Gland 

Technical Description

A1

A2
A3

DEFINITION

TYPE

For unarmoured cable with an elastomeric or plastic outer sheath, with seali ng function between the cable sheath and the
sealing ring of the cable gland.

As type A1, but with seal protection degree IP66
As type A1, but with an electrical bond for the metallic inner screen

Cable Gland Type Designations for Armoured Cables

DEFINITION

CODE

No Seal
Single Outer Seal
Single Inner Seal

Pliable Wire Armour

Single Wire Armour

Braid

Strip Armour

Tape Armour

- Double (Inner & Outer) Seal                     - suffix '1' = Normal                     - suffix '2' = Lead Sheathed

B
C
D
E

SHORT CIRCUIT RATING SYMMETRICAL FAULT CURRENT (KA) FOR 1 SECOND

EARTH TAG SIZE

3.06
4.00
5.40
7.20
10.40
10.40
10.40

20
25
32
40
50
63
75

Cable Type Designations

CODE

T

W

X

Y
Z

D

Industrial Cable Gland

Cable Glands

catalog_eng-html.html
background image

Inspection & Maintenance

The subject of Inspection and maintenance is a very important one, as in common with any non-hazardous
area installations, the presence of an inspection and maintenance regime will always be effective by way of
a preventative measure against the risk of incidents or accidents from arising that may otherwise go
unnoticed. 
The two main IEC Inspection & Maintenance standards that are in use today for gas / vapour hazards 
and dust hazards are detailed below.
IEC 60079 -17 : Electrical apparatus for explosive gas atmospheres - Part 17: Inspection and maintenance 
of electrical installations in hazardous areas (other than mines)

IEC 61241 -17 : Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection
and maintenance of electrical installations in hazardous areas (other than mines)

Table 1  Cable Gland Material Selection

NON-ARMOURED CABLES

E.G. PVC/XLPE

ARMOURED CABLES

AWA or ASA

GSWA, SWA, OR STA

SWB or GSWB

TCWB

BWB

Enclosure / Cable Plate Material

ALUMINUM

BRASS

STAINLESS STEEL

STEEL

NON-METALLIC

CABLE TYPE

Suggested Cable Gland Material

Suggested Cable Gland Material

Aluminum
or Stainless Steel

Brass (*)

Stainless Steel
or Brass (*)

Stainless Steel
or Brass (*)

Brass (*)
or Non-metallic

Aluminum
or Stainless Steel

Stainless Steel or 
Nickel Plated Brass

Stainless Steel or
Nickel Plated Brass

Stainless Steel or 
Nickel Plated Brass

Stainless Steel
or Aluminum

Stainless Steel or
Nickel Plated Brass

Brass (*)

Stainless Steel
or Brass (*)

Stainless Steel
or Brass (*)

Brass (*)

Stainless Steel or
Nickel Plated Brass

Brass (*)

Stainless Steel
or Brass (*)

Stainless Steel
or Brass (*)

Brass (*)

Stainless Steel or
Nickel Plated Brass

Brass (*)

Stainless Steel
or Brass (*)

Stainless Steel
or Brass (*)

Brass (*)

Stainless Steel or
Nickel Plated Brass

Brass (*)

Stainless Steel
or Brass (*)

Stainless Steel
or Brass (*)

Brass (*)

Note

: Where tables make reference to N/P Brass, the definition is Nickel Plated Brass. Where suggested cable gland material is 

Brass (*), the user may also use optional Nickel Plated Brass Cable Glands at their discretion.

Table 2 Electrical Properties - Protective Connection to Earth (Category A, B OR C).

Rms current (kA)

Category A
– Cable Gland only

Category B – with an E
arth Tag attached

Category C – with a heavy
duty integral Earth Lug

Nearest SAMWHA
Cable Gland Size
(Metric)

Cable Diameter

Note

CATEGORY A

, is the minimum requirement which may apply in cases where the cable armouring (other than steel wire) is the 

limiting factor & where the cable gland is screwed into a threaded hole in the metallic equipment enclosure.

CATEGORY B

,  is the medium requirement which may apply in cases where steel wire / metallic sheathed armoured cable is 

used and the system includes a high sensitivity method of secondary protection against fault currents and where earth tags 

are used with the cable gland.

CATEGORY C

,  is the highest requirement, which may apply in cases where steel wire / metallic sheathed armoured cable is

used and the system relies on a low sensitivity method of secondary protection against fault currents and where integral 

earth lugs.

0.5
0.5
0.5
0.5
0.5
1.8
2.3
2.8

3.1
3.1
3.1
4
5.4
7.2
10.4
10.4

10.0
13.1
13.1
13.1
13.1
43.0
43.0
43.0

16
20S
20
25
32
40
50
63

4 to 8

8 to 11

11 to 16

16 to 23

23 to 31

31 to 43

43 to 55

55

Cable Glands

D6 _ D7

(Requirements of

EN 50262 )

Cable Glands

D

catalog_eng-html.html
background image

For Un-armoured 

Cables

KS V 8811

NEMA 4, 4X / IP 55

Rain-tight / Water-tight / Corrosion Resistant

NPT 3/8” (PF 3/8”)
NPT 1/2” (PF 1/2”)
NPT 3/4” (PF 3/4”)
NPT 1” (PF 1”)
NPT 1-1/4” (PF 1-1/4”)
NPT 1-1/2” (PF 1-1/2”)
NPT 1-1/2” (PF 1-1/2”)
NPT 2” (PF 2”)
NPT 2” (PF 2”)
NPT 2-1/2” (PF 2-1/2”)
NPT 2-1/2”(PF 2-1/2”)
NPT 3” (PF 3”)
NPT 3”(PF 3”)
NPT 3” (PF 3”)
NPT 3-1/2” (PF 3-1/2”)
NPT 3-1/2” (PF 3-1/2”)
NPT 4” (PF 4”)
NPT 4” (PF 4”)
NPT 4” (PF 4”)

11.0
11.0
11.0
11.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
15.0
15.0
15.0
15.0
15.0
20.0
20.0
20.0

4.0
6.4
9.5
14.0
19.0
24.5
28.5
33.0
38.5
43.0
49.0
54.5
58.5
63.0
68.5
72.5
76.5
80.0
84.5

8.0
11.0
15.0
20.0
26.0
30.0
34.0
40.0
44.0
50.0
56.0
60.0
64.0
70.0
74.0
78.0
81.0
86.0
100.0

28.0
31.0
37.0
45.0
56.0
63.0
63.0
76.0
76.0
95.0
95.0
110.0
110.0
110.0
130.0
130.0
140.0
140.0
156.0

32.0
36.0
39.0
47.0
53.0
55.0
55.0
60.0
60.0
72.0
72.0
79.0
79.0
79.0
87.0
87.0
105.0
105.0
115.0

CGK
KS V 8811
IP55
-30

°

C to +150

°

C

Un-armoured
Compressed Seal
Cable Outer Sheath
Adaptor/Reducer

Cable Gland Selection Table

#10
#15
#20
#25
#30
#35
#40
#45
#50
#55
#60
#65
#70
#75
#80
#85
#90
#95

#100

Cable 

Gland Size 

Available Entry 

Threads  BSPP OR NPT  “B”

Minimum 

Thread Length 

Overall Cable Diameter  “A” Across Corners“D”

Max 

Protrusion 

Length  

“C”

Min

Max 

Model
Design Specification
Ingress Protection Rating
Continuous Operating Temperature

Cable Type
Sealing Technique
Sealing Area(s)
Optional Accessories

TECHNICAL DATA

Applications

CGK Type indoor and outdoor cable gland for use with all types of Un-armoured cable, providing an
environmental seal on the cable outer sheath. 

Features

The CGK type range of industrial cable glands is designed and tested to KS V 8811 All metallic cable gland
components are manufactured from the same grade of material. Brass locknuts are produced in the same CU
Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168:  1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

IP55-Neoprene or Rubber”O”ring

Standard Finishes

Brass

Natural or Nickel-Cr Plated

Compliances / Approvals

IEC 60529 Degree of protection provided
by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe 

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where

pressure-tight joints are not made on the

threads.

CGK Un-armoured, Outer Sheath Seal  

CGK Industrial Cable Gland 

D

Industrial Cable Gland

Cable Glands

catalog_eng-html.html
background image

NEMA 4, 4X / IP 55

Rain-tight / Water-tight / Corrosion Resistant

3.5
6.5
9.5
3.5
6.5
9.5
12.7
16.0
19.0
19.0
22.5
25.5
28.5
30.2
22.5
25.5
28.5
32.0
32.0
28.5
32.0
36.0
36.0
40.0
36.0
40.0
41.5
44.5
49.5
47.5
55.5
49.5
55.5
49.5
55.5
63.5
76.2
63.5
76.0
89.0

6.5
9.5
12.7
6.5
9.5
12.7
16.0
12.7
16.0
19.0
22.5
22.5
25.5
28.5
32.0
32.0
25.5
28.5
32.0
35.0
36.0
32.0
36.0
40.0
41.5
44.5
40.0
44.5
47.5
49.5
54.5
55.5
60.0
55.5
63.5
67.3
88.9
76.0
89.0
108.0

16

22

28

36

42

54

70

82

90

104

130

1/2”

3/4”

1”

1-1/4”

1-1/2”

2”

2-1/2”

3”

3-1/2”

4”

5”

1/2”

3/4”

1”

1-1/4”

1-1/2”

2”

2-1/2”

3”

3-1/2”

4”

5”

13.0

14.0

15.0

18.0

18.0

21.0

24.0

28.0

32.0

32.0

39.0

14.0

14.0

18.0

18.0

19.0

21.0

39.0

41.0

41.0

44.0

45.0

32.0

38.0

46.0

55.0

62.0

75.0

92.0

108.0

136.0

136.0

164.0

35.0

41.0

49.0

59.0

66.0

80.0

98.0

114.0

142.0

142.0

170.0

27.0

27.0

35.0

38.0

38.0

43.0

70.0

75.8

89.0

91.0

86.0

Cable 

Gland Size 

Available Entry Threads”D” Minimum Thread Length ”F”  Overall Cable Diameter “A”

Across Corners “C”

Across Flats“B”

Max Max 

Protrusion 

Length 

“E” 

Min

BSPP

NPT BSPP NPT

Max 

A
B
C
A
B
C
D
A
B
C
D
A
B
C
D
E
A
B
C
D
E
A
B
C
D
E
A
B
C
D
E
F
G
A
B
A
B
A
B
A

For Un-armoured 

Cables

CGK
Compressed Seal
IP55
-30

°

C to +150

°

C

Un-armoured
Cable Outer Sheath
Adaptor/Reducer

Cable Gland Selection Table

Model
Sealing Technique
Ingress Protection Rating
Continuous Operating Temperature

Cable Type
Sealing Area(s)
Optional Accessories

TECHNICAL DATA

Applications

CGC Type indoor and outdoor cable gland for use with all types of Un-armoured cable, providing an
environmental seal on the cable outer sheath.

Features

All metallic cable gland components are manufactured from the same grade of material. Brass locknuts are
produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

IP55

Neoprene or Rubber  “O” ring

Standard Finishes

Brass

Natural or Nickel-Cr Plated

Compliances / Approvals

IEC 60529 Degree of protection provided
by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe threads,

General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where

pressure-tight joints are not made on the 

threads.

CGC Un-armoured, Outer Sheath Seal  

CGC Industrial Cable Gland 

Cable Glands

D8 _ D9

Cable Glands

D

catalog_eng-html.html
background image

For Un-armoured 
Cables

BS 6121 : 

Part 1 : 1989

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

10.0
10.0
10.0
10.0
10.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

3.1
7.0
11.0
13.0
19.0
25.0
31.5
36.5
42.5
48.5
54.5
60.5
67.5

8.6
11.6
13.9
19.9
24.2
32.1
38.1
44.0
47.3
55.9
61.9
67.9
79.3

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

28.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
98.0
99.0
110.0
132.0

26.5
26.5
26.5
28.5
32.5
40.5
40.5
40.5
42.5
43.0
46.0
46.0
47.5

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

A2
BS 6121:Part 1:1989, EN 50262:1999
Retention = Class B, Impact = Level 8
-30

°

C to +150

°

C

IP66
Un-armoured
Cable Outer Sheath

Adaptor/Reducer, Earth Tag, Serrated Washer, Shroud

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads “C”

Standard

Metric

NPT

NPT

Option

Minimum 

Thread Length 

“E”

Overall Cable

Diameter  “A”

Across 

Flats “D”

Across 

Corners 

Max Max 

PVC

Shroud Ref

Protrusion 

Length 

“F”

Min

Max 

Model
Design Specification
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Cable Type
Sealing Technique
Sealing Area(s)
Optional Accessories

TECHNICAL DATA

Applications

A2 Type indoor and outdoor cable gland for use with all types of Un-armoured cable, providing mechanical
cable retention and an environmental seal on the cable outer sheath.

Features

The A2 type range of industrial cable glands is designed and tested to BS 6121:Part 1:1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts are
produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874 : 1986)

Stainless Steel 

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel 

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber ”O” ring

Standard Finishes

Brass

Natural or Nickel Plated                

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60529 Degree of protection provided  
by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe 

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where 

pressure-tight joints are not made on the 
threads

PG

DIN 40430 : 1971  PG threads

Metric

ISO 965-1, ISO 965-3 medium 

fit(6g) for external threads

BS 6121 : Part 1 : 1989

A2 Un-armoured, Outer Sheath Seal  

A2 Industrial Cable Gland 

NEMA 4, 4X / IP 66

Rain-tight / Water-tight / Corrosion Resistant 

D

Industrial Cable Gland

Cable Glands

catalog_eng-html.html
background image

C

A

B

D

E

F

For Armoured 
Cables

BS 6121 :

Part 1 : 2005

BW
BS 6121:Part 1:2005, EN 50262:1999
Retention = Class B, Impact = Level 8
-20

°

C to +150

°

C

Armoured
Two part Amour Lock

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Model
Design Specification
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Cable Type
Armour Clamping

Optional Accessories

TECHNICAL DATA

Applications

BW Type indoor cable gland for use with all types of Single Wire armoured (SWA) cable, providing
mechanical cable retention and electrical continuity via armour wire termination.

Features

The BW type range of industrial cable glands is designed and tested to BS 6121:Part 1:2005.
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts are
produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874 : 1986)

Stainless Steel

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel

BS970 Part 1 : 1996 Grade 220MO7Pb

Standard Finishes

Brass

Natural or Nickel Plated               

Mild Steel

Electro Zinc Plated

Compliances / Approvals

NPT

ANSI / ASME B 1.20.1 Pipe 

threads, General purpose (Inch)

BSPP

SO 228/1 Pipe threads 

where pressure-tight joints
General purpose (Inch)

are not made on the threads

PG

DIN 40430 : 1971  PG threads

Metric

ISO 965-1, ISO 965-3 

medium fit (6g) for external threads

BS 6121 : Part 1 : 2005

BW Armoured, None Seal  

BW Industrial Cable Gland

M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75

3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"

10.0
10.0
10.0
10.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"

11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9

15.9
20.9
27.4
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5

2.5
2.5
2.5

0.9
0.9
1.25
1.6
1.6
2.0
2.0

1.25
1.25
1.6
2.0
2.0
2.5
2.5

2.5

3.15

31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0

24.0
24.0
24.0
28.0
31.0
33.0
33.0
40.0
41.0
47.5
47.5

GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75

Cable Gland Selection Table

20S

20
25
32
40

50S

50

63S

63

75S

75

Cable

Gland Size

Available Entry Threads “C”

Standard

Metric

NPT

NPT

Option

Minimum 

Thread Length 

“E”

Cable

Bedding 

Diameter “A”

Overall

Cable 

Diameter “B”

Across 

Flats

“D”

Across 

Corners 

Min

Max Max 

PVC

Shroud Ref

Protrusion 

Length

“F” 

Max 

Max 

Cable Glands

D10 _ D11

Cable Glands

D

catalog_eng-html.html
background image

For Armoured 
Cables

BS 6121 : 

Part 1 : 1989

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

10.0
10.0
10.0
10.0
10.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

8.6
11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9
79.3

8.0
12.0
15.0
20.0
26.5
33.0
39.0
45.5
52.0
58.0
64.0
71.0
78.5

13.4
15.9
20.9
27.4
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5
90.4

0.9
0.9
1.25
1.6
1.6
2.0
2.0

1.25
1.25
1.6
2.0
2.0
2.5
2.5

2.5

3.15

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

0.9

2.5
2.5
2.5

3.15

29.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

69.0
69.0
69.0
74.0
80.0
90.0
93.0
93.0
104.0
104.0
110.0
110.0
112.0

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

CW
BS 6121:Part 1:1989, EN 50262:1999
Retention = Class B, Impact = Level 8
-30

°

C to +150

°

C

IP66

Armoured
Displacement Seal
Cable Outer Sheath

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads”C”

Standard

Metric

NPT

NPT

Option

Minimum 

Thread
Length

“E”

Overall Cable 
Diameter “B” 

Armour Range 

Across

Flats

“D”

Across

Corners

Max Max 

Max 

Max 

Min

Protrusion 

Length

“F” 

PVC 

Shroud

Ref 

Max 

Min

Model
Design Specification
EN 50262 Mechanical Classifications
Continuous Operating Temperature
Ingress Protection Rating

Cable Type
Sealing Technique
Sealing Area(s)

Optional Accessories

TECHNICAL DATA

Applications

CW Type indoor and outdoor cable gland for use with Single Wire Armoured (SWA) Cable providing an
environmental seal on the cable outer sheath, providing mechanical cable retention and electrical
continuity via armour wire termination. 

Features

The CW type range of industrial cable glands is designed and tested to BS 6121:Part 1:1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar 

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

Stainless Steel 

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel 

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber ”O” ring

Standard Finishes

Brass

Natural or Nickel Plated             

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60529 Degree of protection provided  
by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe 

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where 

pressure-tight joints are not made on the 
threads

PG

DIN 40430:1971  PG threads

Metric

ISO 965-1, ISO 965-3 medium 

fit(6g) for external threads

BS 6121 : Part 1 : 1989

CW Armoured, Outer Sheath Seal  

CW Industrial Cable Gland 

NEMA 4, 4X / IP 66

Rain-tight / Water-tight / Corrosion Resistant 

D

Industrial Cable Gland

Cable Glands

Cable

Bedding

Diameter

“A” 

catalog_eng-html.html
background image

For Armoured 
Cables

BS 6121 : 

Part 1 : 1989

Applications

CX Type indoor and outdoor cable gland for use with all types of Wire Braid, Strip Armour, Pliable Wire
Armour & Steel Tape Armour (STA) Cable providing an environmental seal on the cable outer sheath,
providing mechanical cable retention and electrical continuity via armour wire termination . 

Features

The CX type range of industrial cable glands is designed and tested to BS 6121:Part 1:1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874 :1986)

Stainless Steel

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber ”O” ring

Standard Finishes

Brass

Natural or Nickel Plated              

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60529 Degree of protection provided by  enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe 

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where 

pressure-tight joints are not made on the 
threads

PG

DIN 40430 :1971  PG threads

Metric

ISO 965-1, ISO 965-3 medium 

fit(6g) for external threads

BS 6121 : Part 1 : 1989

CX Armoured, Outer Sheath Seal  

CX Industrial Cable Gland

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

10.0
10.0
10.0
10.0
10.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

8.6
11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9
79.3

8.0
12.0
15.0
20.0
26.5
33.0
39.0
45.5
52.0
58.0
64.0
71.0
78.5

13.4
15.9
20.9
27.4
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5
90.4

0
0
0
0
0
0
0
0
0
0
0
0
0

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.6

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

29.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

48.5
48.5
49.0
53.0
58.0
59.5
64.0
64.0
72.5
72.5
77.5
77.5
77.0

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

CX
BS 6121:Part 1:1989, EN 50262:1999
Retention = Class B, Impact = Level 8
-30

°

C to +150

°

C

IP66

Armoured
Displacement Seal
Cable Outer Sheath

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads “C”

Standard

Metric

NPT

NPT

Option

Minimum 

Thread
Length 

“E”

Overall Cable 

Diameter  “B”

Cable

Bedding

Diameter

“A” 

Armour Range 

Across

Flats

“D”

Across

Corners

Max Max 

Max 

Max 

Min

Protrusion 

Length 

“F”

PVC 

Shroud

Ref 

Max 

Min

Model
Design Specification
EN 50262 Mechanical Classifications
Continuous Operating Temperature
Ingress Protection Rating

Cable Type
Sealing Technique
Sealing Area(s)

Optional Accessories

TECHNICAL DATA

NEMA 4, 4X / IP 66 

Rain-tight / Water-tight / Corrosion Resistant 

Cable Glands

D12 _ D13

Cable Glands

D

catalog_eng-html.html
background image

For Armoured 
Cables

BS 6121 : 

Part 1 : 1989

CXT
BS 6121:Part 1:1989, EN 50262:1999
Retention = Class B, Impact = Level 8
-30

°

C to +150

°

C

IP66

Armoured
Displacement Seal
Cable Outer Sheath

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Model
Design Specification
EN 50262 Mechanical Classifications
Continuous Operating Temperature
Ingress Protection Rating

Cable Type
Sealing Technique
Sealing Area(s)

Optional Accessories

TECHNICAL DATA

Applications

CXT Type indoor and outdoor cable gland for use with all types of Screened Flexible Wire Braid or Wire
Braid Armour Cable providing an environmental seal on the cable outer sheath, providing mechanical
cable retention and electrical continuity via armour wire termination. 

Features

The CXT type range of industrial cable glands is designed and tested to BS 6121:Part 1:1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

C

A

D

E

F

Standard Materials

Brass Extruded bar

EN12168: 1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

Stainless Steel

EN10088-2:2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber ”O” ring

Standard Finishes

Brass

Natural or Nickel Plated             

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60529 Degree of protection provided  
by enclosures (IP Code)

Metric

ISO 965-1, ISO 965-3 medium 

fit(6g) for external threads

BS 6121 : Part 1 : 1989

CXT Armoured, Outer Sheath Seal  

CXT Industrial Cable Gland

NEMA 4, 4X / IP 66

Rain-tight / Water-tight / Corrosion  Resistant

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

3.1
7.0
11.0
13.0
19.0
25.0
31.5
36.5
42.5
48.5
54.5
60.5
67.5

8.6
11.6
13.9
19.9
24.2
32.1
38.1
44.0
47.3
55.9
61.9
67.9
79.3

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

28.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

26.5
26.5
26.5
28.5
32.5
40.5
40.5
40.5
42.5
43.0
46.0
46.0
47.5

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable 

Gland Size 

Entry 

Thread

“C”

Minimum

Thread Length 

“E”

Overall Cable Diameter “A”  Across  Flats

“D”

Across Corners 

Protrusion

Length 

“F”

PVC 

Shroud Ref 

Min

Max Max Max 

D

Industrial Cable Gland

Cable Glands

catalog_eng-html.html
background image

For Armoured 
Cables

BS 6121 : 

Part 1 : 1989

Applications

E1W Type indoor and outdoor cable gland for use with Single Wire Armoured (SWA) Cable providing an
environmental seal on the cable outer sheath and the cable inner sheath, providing mechanical cable
retention and electrical continuity via armour wire termination. 

Features

The E1W type range of industrial cable glands is designed and tested to BS 6121:Part 1:1989 
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar 

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874 : 1986)

Stainless Steel 

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel 

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber “O” ring

Standard Finishes

Brass

Natural or Nickel Plated              

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60529 Degree of protection provided by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe 

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where 

pressure-tight joints are not made on the 
threads

PG

DIN 40430:1971  PG threads

Metric

ISO 965-1, ISO 965-3 medium 

fit(6g) for external threads

BS 6121 : Part 1 : 1989

E1W Armoured, Outer & Inner Sheath Seal  

E1W Industrial Cable Gland 

E1W
BS 6121:Part 1:1989, EN 50262:1999
Retention = Class B, Impact = Level 8
-30

°

C to +150

°

C

IP66

Armoured
Displacement Seal
Cable Inner Sheath and Outer Sheath

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Model
Design Specification
EN 50262 Mechanical Classifications
Continuous Operating Temperature
Ingress Protection Rating

Cable Type
Sealing Technique
Sealing Area(s)

Optional Accessories

TECHNICAL DATA

NEMA 4, 4X / IP 66

Rain-tight / Water-tight / Corrosion Resistant

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

10.0
10.0
10.0
10.0
10.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

3.1
7.0
11.0
13.0
19.0
25.0
31.5
36.5
42.5
48.5
54.5
60.5
67.5

8.6
11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9
79.3

8.0
12.0
15.0
20.0
26.5
33.0
39.0
45.5
52.0
58.0
64.0
71.0
78.5

13.4
15.9
20.9
27.4
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5
90.4

1.25
1.25
1.6
2.0
2.0
2.5
2.5

0.9
0.9
1.25
1.6
1.6
2.0
2.0

2.5

3.15

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

0.9

2.5
2.5
2.5

3.15

29.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

69.0
69.0
69.0
74.0
80.0
90.0
93.0
93.0
104.0
104.0
110.0
110.0
112.0

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads“C”

Standard

Metric

NPT

NPT

Option

Minimum 

Thread
Length

“E” 

Overall Cable 
Diameter “B”

Cable Bedding

Diameter “A” 

Armour Range 

Across

Flats

“D”

Across

Corners

Max Max 

Max 

Max 

Min

Protrusion 

Length

“F” 

PVC 

Shroud

Ref 

Min

Min

Max 

Cable Glands

D14 _ D15

Cable Glands

D

catalog_eng-html.html
background image

For Armoured 
Cables

BS 6121 : 

Part 1 : 1989

E1X
BS 6121:Part 1:1989, EN 50262:1999
Retention = Class B, Impact = Level 8
-30

°

C to +150

°

C

IP66

Armoured
Displacement Seal
Cable Inner Sheath and Outer Sheath

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Model
Design Specification
EN 50262 Mechanical Classifications
Continuous Operating Temperature
Ingress Protection Rating

Cable Type
Sealing Technique
Sealing Area(s)

Optional Accessories

TECHNICAL DATA

Applications

E1X Type indoor and outdoor cable gland for use with all types of Wire Braid Armour, Strip Armour, Pliable
Wire Armour & Steel Tape Armour Cable providing an environmental seal on the cable outer sheath and
the cable inner sheath , providing mechanical cable retention and electrical continuity via armour wire
termination. 

Features

The E1X type range of industrial cable glands is designed and tested to BS 6121 : Part 1 : 1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874 : 1986)

Stainless Steel

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber ”O” ring

Standard Finishes

Brass

Natural or Nickel Plated               

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60529 Degree of protection provided  
by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe 

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where 

pressure-tight joints are not made on the 
threads

PG

DIN 40430 : 1971  PG threads

Metric

ISO 965-1, ISO 965-3 

medium fit(6g) for external threads

BS 6121 : Part 1 : 1989

E1X Armoured, Outer & Inner Sheath Seal  

E1X Industrial Cable Gland

NEMA 4, 4X / IP 66

Rain-tight / Water-tight / Corrosion  Resistant

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

10.0
10.0
10.0
10.0
10.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

3.1
7.0
11.0
13.0
19.0
25.0
31.5
36.5
42.5
48.5
54.5
60.5
67.5

8.6
11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9
79.3

8.0
12.0
15.0
20.0
26.5
33.0
39.0
45.5
52.0
58.0
64.0
71.0
78.5

13.4
15.9
20.9
27.4
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5
90.4

0
0
0
0
0
0
0
0
0
0
0
0
0

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.6

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

29.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

69.0
69.0
69.0
74.0
80.0
90.0
93.0
93.0
104.0
104.0
110.0
110.0
112.0

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads “C”

Standard

Metric

NPT

NPT

Option

Minimum 

Thread
Length 

“E”

Overall Cable 
Diameter “B”

Cable Bedding

Diameter “A”

Armour Range 

Across

Flats

“D”

Across

Corners

Min

Max Max Max 

Min

Protrusion

Length 

“F”

PVC 

Shroud

Ref 

Min

Max Max 

D

Industrial Cable Gland

Cable Glands

catalog_eng-html.html
background image

Rain-tight / Water-tight / Corrosion  Resistant

For Armoured 
Cables

For Inner Lead

Sheathed Cables

BS 6121 : 

Part 1 : 1989

E2W
BS 6121:Part 1:1989, EN 50262:1999
Retention = Class B, Impact = Level 8
-30

°

C to +150

°

C

IP66

Armoured
Displacement Seal
Cable Inner Lead Sheath and Outer Sheath

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Model
Design Specification
EN 50262 Mechanical Classifications
Continuous Operating Temperature
Ingress Protection Rating

Cable Type
Sealing Technique
Sealing Area(s)

Optional Accessories

TECHNICAL DATA

Applications

E2W Type indoor and outdoor cable gland for use with all types of Lead Sheathed and Single Wire
Armoured (SWA) Cable providing an environmental seal on the cable outer sheath and the cable inner lead
sheath , providing mechanical cable retention and electrical continuity via armour wire termination. 

Features

The E2W type range of industrial cable glands is designed and tested to BS 6121:Part 1:1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874 : 1986)

Stainless Steel

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber ”O” ring

Standard Finishes

Brass

Natural or Nickel Plated               

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60529 Degree of protection provided  
by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe 

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where 

pressure-tight joints are not made on the 
threads

PG

DIN 40430 : 1971  PG threads

Metric

ISO 965-1, ISO 965-3 

medium fit (6g) for external threads

BS 6121 : Part 1 : 1989

E2W Armoured, Outer & Inner Sheath Seal, Lead Sheath  

E2W Industrial Cable Gland 

NEMA 4, 4X / IP 66

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

10.0
10.0
10.0
10.0
10.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

3.1
7.0
11.0
13.0
19.0
25.0
31.5
36.5
42.5
48.5
54.5
60.5
67.5

8.6
11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9
79.3

8.0
12.0
15.0
20.0
26.5
33.0
39.0
45.5
52.0
58.0
64.0
71.0
78.5

13.4
15.9
20.9
27.4
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5
90.4

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

29.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

69.0
69.0
69.0
74.0
80.0
90.0
93.0
93.0
104.0
104.0
110.0
110.0
112.0

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads “C”

Standard

Metric

NPT

NPT

Option

Minimum 

Thread
Length 

“E”

Overall Cable 
Diameter “B”

Cable Bedding

Diameter “A”

Armour Range 

Across

Flats

“D”

Across

Corners

Min

Max Max Max 

Min

Protrusion

Length 

“F”

PVC 

Shroud

Ref 

Min

Max Max 

1.25
1.25
1.6
2.0
2.0
2.5
2.5

0.9
0.9
1.25
1.6
1.6
2.0
2.0

2.5

3.15

0.9

2.5
2.5
2.5

3.15

Cable Glands

D16 _ D17

Cable Glands

D

catalog_eng-html.html
background image

For Armoured 
Cables

Applications

SECTION VIEW  : A-A’

BCW Type indoor cable gland for use with Single Wire Armoured (SWA) Cable providing mechanical cable
retention and electrical continuity via armour wire termination. 

Features

All metallic cable gland components are manufactured from the same grade of material. 

Standard Materials

Body 

Cast Brass                                       

Bolt & Clamp

Steel

Standard Finishes

Cast Brass

Natural                                   

Steel

Electro Zinc Plated

Compliances / Approvals

NPT

ANSI / ASME B 1.20.1 Pipe threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where pressure-tight joints are not made on the threads

PG

DIN 40430 :1971  PG threads

Metric

ISO 965-1, ISO 965-3 medium fit (6g) for external threads

Specification & Dimensions

BCW Armoured  

BCW Industrial Cable Gland

Body
Armour Clamp
Body Fix Bolt
Body Fix Nut
Body Fix Spring Washer
Body Fix Washer
Armour Clamp Fix Bolt
Armour Clamp Fix Nut
Armour Clamp Spring Washer
Armour Clamp Fix Washer
Earth Bolt
Earth Spring Washer
Earth Washer
Body Gasket

Cast Brass
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel

Electro Zinc Plated
M12
M12
M12
M12
M10
M10
M10
M10
M10
M10
M10

1
2
3
4
5
6
7
8
9
10
11
12
13
14

NO

Description

Material

Specification

D

Industrial Cable Gland

Cable Glands

catalog_eng-html.html
background image

Cable Glands

D18 _ D19

Hazardous Area Type Cable Gland

Cable Glands

For Un-armoured 
Cables

ECG
IEC60079-0,1:2007
ATEX II 2G Ex d IIC, Ex e II
Ex d II C, Ex e II
Retention = Class B, Impact = Level 6
-20 °C to +80 °C

IP65
Un-armoured
Displacement Seal
Cable Outer Sheath
Adaptor/Reducer

Model
Design Specification
ATEX Code of Protection Category
IEC Ex Code of Protection Category
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Ingress Protection Rating
Cable Type
Sealing Technique
Sealing Area(s)
Optional Accessories 

TECHNICAL DATA

Applications

ECG Type indoor and outdoor cable gland for use in Zone1, Zone2 hazardous areas with all types of Un-
armoured cable, providing mechanical cable retention and an environmental seal on the cable outer
sheath.

Features

All metallic cable gland components are manufactured from the same grade of material. Brass locknuts are
produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874 : 1986)

Stainless Steel

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel

BS970 Part 1 : 1996 Grade 220MO7Pb

IP65-Neoprene or Rubber “O” ring

Standard Finishes

Brass

Natural or Nickel Plated               

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment-General

requirements

EC 60079-1 Equipment protection by

flameproof enclosures ”d”

IEC 60079-7 Equipment protection by

increased safety ”e”

IEC 60529 Degree of protection provided 

by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where

pressure-tight joints are not made on 
the threads

ECG Un-armoured, Outer Sheath Seal, Ex d & Ex e”

ECG Flame-proof Ex d & Increased Safety Ex e Cable Gland

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X / II 2G Ex d II C & Ex e II  IP 65

Explosion-proof / Rain-tight / Water-tight / Corrosion  Resistant

1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"

1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"

17.0
17.0
21.0
21.0
26.0
27.0
30.0
30.0
31.0

7.0
10.5
16.5
20.6
23.7
30.9
40.3
52.6
64.2

11.0
15.0
21.3
27.0
29.0
39.0
51.0
63.0
75.0

32.0
38.0
50.0
55.0
63.0
75.0
95.0
108.0
140.0

36.0
41.0
50.0
55.0
63.0
75.0
95.0
108.0
144.0

64
66
72
83
92
93
94
109
125

Cable Gland Selection Table

16
22
28
36
42
54
70
82

104

Cable

Gland Size

Available Entry Threads “D”

Standard

BSPP

NPT

Minimum 

Thread Length

“E” 

Overall Cable Diameter 

“A”

Across Flats

“B” 

Across Corners

“C”

Max Max 

Protrusion 

Length 

“F”

Min

Max 

Cable Glands

D

catalog_eng-html.html
background image

For Un-armoured 
Cables

Compound

Barrier Type

ECG-CB
IEC60079-0,1:2007
ATEX II 2G Ex d IIC, Ex e II
Ex d II C, Ex e II
Retention = Class B, Impact = Level 6
-20 

°

C to +80

°

C

IP65
Un-armoured
Compound Barrier
Cable Outer Sheath
Adaptor/Reducer

Model
Design Specification
ATEX Code of Protection Category
IEC Ex Code of Protection Category
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Ingress Protection Rating
Cable Type
Sealing Technique
Sealing Area(s)
Optional Accessories 

TECHNICAL DATA

Applications

ECG-CB Type indoor and outdoor cable gland for use in Zone1, Zone2 hazardous areas with all types of Un-
armoured cable, providing a compound barrier seal around the conductors and an environmental seal on
the cable outer sheath.

Features

All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874 : 1986)

Stainless Steel

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel

BS970 Part 1 : 1996 Grade 220MO7Pb

IP65-Neoprene or Rubber “O” ring

Standard Finishes

Brass

Natural or Nickel Plated               

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment-General

requirements

EC 60079-1 Equipment protection by

flameproof enclosures ”d”

IEC 60079-7 Equipment protection by

increased safety ”e”

IEC 60529 Degree of protection provided 

by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where

pressure-tight joints are not made on 
the threads

1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"

1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"

17.0
17.0
21.0
21.0
26.0
27.0
30.0
30.0
31.0

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

8.5
13.0
19.0
26.0
32.0
40.0
50.0
62.0
74.0

32.0
38.0
50.0
55.0
63.0
75.0
95.0
108.0
140.0

36.0
41.0
50.0
55.0
63.0
75.0
95.0
108.0
144.0

64
66
72
83
92
93
94
109
125

Cable Gland Selection Table

16
22
28
36
42
54
70
82

104

Cable

Gland Size

Available Entry Threads “D”

Standard

BSPP

NPT

Minimum 

Thread Length

“E” 

Overall Cable Diameter 

“A”

Across Flats 

“B”

Across Corners

“C”

Max Max 

Protrusion 

Length 

“F”

Min

Max 

D

Hazardous Area Type Cable Gland

Cable Glands

ECG-CB Un-armoured, Outer Sheath Seal, “Ex d & Ex e”

ECG-CB Flame-proof Ex d & Increased Safety Ex e Cable Gland

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X / II 2G Ex d II C & Ex e II  IP 65

Explosion-proof / Rain-tight / Water-tight / Corrosion  Resistant

catalog_eng-html.html
background image

Cable Glands

D20 _ D21

For Un-armoured 
Cables

Bell Type

EGB
IEC60079-0,1:2007
ATEX II 2G Ex d IIC
Ex d II C
Retention = Class B, Impact = Level 6
-20 

°

C to +80

°

C

IP65
Un-armoured
Compressed Seal
Cable Outer Sheath
Adaptor/Reducer

Model
Design Specification
ATEX Code of Protection Category
IEC Ex Code of Protection Category
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Ingress Protection Rating
Cable Type
Sealing Technique
Sealing Area(s)
Optional Accessories 

TECHNICAL DATA

Applications

EGB Type indoor and outdoor cable gland for use in Zone1, Zone2 hazardous areas with all types of Un-
armoured cable, providing mechanical cable retention and an environmental seal on the cable outer
sheath.

Features

All metallic cable gland components are manufactured from the same grade of material. Aluminum
locknuts are produced in the same ASTM B26 356-T6 (AC4C-T6) grade as the cable gland.

Standard Materials

Copper Free Aluminum

IP65-Neoprene or Rubber “O” ring

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5)

Compliances / Approvals

IEC 60079-0 Equipment-General requirements

EC 60079-1 Equipment protection by flameproof 

enclosures ”d”

IEC 60079-7 Equipment protection by increased safety ”e”

IEC 60529 Degree of protection provided 

by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe threads, General 

purpose (Inch)

BSPP

ISO 228/1 Pipe threads where pressure-tight 

joints are not made on 
the threads

EGB Un -armoured, Outer Sheath Seal, “Ex d”  

EGB Flame-proof Ex d Cable Gland 

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X / II 2G Ex d II C  IP 65

Explosion-proof / Rain-tight / Water-tight / Corrosion  Resistant

1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"

1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"

18.0
18.0
24.0
26.0
26.0
27.0
30.0
40.0
45.0

9.0
11.0
14.0
26.0
27.5
33.5
48.0
47.0
82.0

11.5
16.0
20.0
27.0
32.5
43.5
55.0
67.5
90.0

25.0
26.0
27.0
42.0
47.0
55.0
62.0
65.0
85.0

49.0
50.0
58.0
76.0
85.0
94.0
110.0
130.0
160.0

73.0
80.0
95.0
138.0
155.0
170.0
170.0
180.0
240.0

Cable Gland Selection Table

16
22
28
36
42
54
70
82

104

Cable

Gland Size

Available Entry Threads “A”

Standard

BSPP

NPT

Minimum 

Thread Length

“B” 

Overall Cable Diameter 

Rotate

Radius

“E”

Across Corners

“C”

Max Max 

Protrusion 

Length 

“D”

Min

Max 

Cable Glands

D

catalog_eng-html.html
background image

For Un-armoured 
Cables

Compound Type

EGC
IEC60079-0,1:2007
ATEX II 2G Ex d IIC
Ex d II C
Retention = Class B, Impact = Level 6
-20

°

C to +80

°

C

IP65
Un-armoured
Compressed Seal
Cable Outer Sheath
Adaptor/Reducer

Model
Design Specification
ATEX Code of Protection Category
IEC Ex Code of Protection Category
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Ingress Protection Rating
Cable Type
Sealing Technique
Sealing Area(s)
Optional Accessories 

TECHNICAL DATA

Applications

EGC Type indoor and outdoor cable gland for use in Zone1, Zone2 hazardous areas with all types of Un-
armoured cable, providing mechanical cable retention and an environmental seal on the cable outer
sheath.

Features

All metallic cable gland components are manufactured from the same grade of material. Aluminum locknuts are
produced in the same ASTM B26 356-T6 (AC4C-T6) grade as the cable gland.

Standard Materials

Copper Free Aluminum

IP65 – Neoprene or Rubber “O”ring

Standard Finishes

Spray (Color : Munsel No. 7.5BG 6/1.5

Compliances / Approvals

IEC 60079-0 Equipment-General requirements

EC 60079-1 Equipment protection by  flameproof

enclosures ”d”

IEC 60529 Degree of protection provided by 

enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe threads, 

General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where pressure-

tight joints are not made on the threads

EGC Un-armoured, Outer Sheath Seal, “Ex d”  

EGC Flame-proof Ex d Cable Gland

1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"

1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"

18.0
18.0
24.0
26.0
26.0
27.0
30.0
40.0
45.0

9.0
11.0
14.0
26.0
27.5
33.5
48.0
47.0
82.0

11.5
16.0
20.0
27.0
32.5
43.5
55.0
67.5
90.0

25.0
26.0
27.0
42.0
47.0
55.0
62.0
65.0
85.0

49.0
50.0
58.0
76.0
85.0
94.0
110.0
130.0
160.0

73.0
80.0
95.0
125.0
145.0
148.0
160.0
160.0
200.0

Cable Gland Selection Table

16
22
28
36
42
54
70
82

104

Cable

Gland Size

Available Entry Threads “A”

Standard

BSPP

NPT

Minimum 

Thread Length

“B” 

Overall Cable Diameter 

Rotate

Radius

“E”

Across Corners

“C”

Max Max 

Protrusion 

Length 

“D”

Min

Max 

D

Hazardous Area Type Cable Gland

Cable Glands

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X / II 2G Ex d II C  IP 65

Explosion-proof / Rain-tight / Water-tight / Corrosion  Resistant

catalog_eng-html.html
background image

Cable Glands

D22 _ D23

For Un-armoured 
Cables

Conduit Type

For Three or

Four Wires (3P-1E

or 3P)

4” Only

Cable Multi

Clamping

MCG
IEC60079-0,1:2007
ATEX II 2G Ex d IIC
Ex d II C
Retention = Class B, Impact = Level 6
-20

°

C to +80

°

C

IP65
Un-armoured
Displacement Seal
Cable Outer Sheath
Adaptor/Reducer
For Three or Four Wires

Model
Design Specification
ATEX Code of Protection Category
IEC Ex Code of Protection Category
EN 50262 Mechanical Classifications
Continuous Operating Temperature

MCG 104A Clamp 3P+1E 

MCG 104B Clamp 3P

Ingress Protection Rating
Cable Type
Sealing Technique
Sealing Area(s)
Optional Accessories 
Number Of Cable Grip

TECHNICAL DATA

Applications

MCG Type indoor and outdoor Multi Core cable gland for use in Zone1, Zone2 hazardous areas with all
types of Un-armoured cable, providing mechanical cable retention and an environmental seal on the cable
outer sheath.

Features

All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874 : 1986)

Stainless Steel

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel

BS970 Part 1 : 1996 Grade 220MO7Pb

IP65-Neoprene or Rubber “O” ring

Standard Finishes

Brass

Natural or Nickel Plated          

Mild Steel

Electro Zinc Plated

Compliances / Approvals

Dimensions

IEC 60079-0 Equipment-General

requirements

EC 60079-1 Equipment protection by

flameproof enclosures ”d”

IEC 60529 Degree of protection provided 

by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where

pressure-tight joints are not made on 
the threads

MCG Un-armoured, Outer Sheath Seal, “Ex d”

MCG Multi Core Custom Build Flame-proof Ex d Cable Gland 

4”

4”

37.0

92.0

132.0

139.0

157.0

32.0
37.0

23.0

-

MCG104 A
MCG104 B

Cable

Gland Size

Available Entry Threads

Standard

BSPP

NPT

Minimum 

Thread Length 

Overall Cable Diameter

(Max)

Inner

Diameter

Across 

Flats

Across 

Corners

Max Max Max 

Protrusion 

Length 

3P

1E

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X / II 2G Ex d II C  IP 65

Explosion-proof / Rain-tight / Water-tight / Corrosion  Resistant

Cable Glands

D

catalog_eng-html.html
background image

Construction

For Un-armoured 
Cables

Conduit Type

For Three or

Four Wires (3P-1E

or 3P)

4” Only

Cable Multi

Clamping

MCG Un-armoured, Outer Sheath Seal, “Ex d”

MCG Multi Core Custom Build Flame-proof Ex d Cable Gland 

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X / II 2G Ex d II C  IP 65

Explosion-proof / Rain-tight / Water-tight / Corrosion  Resistant

D

Hazardous Area Type Cable Gland

Cable Glands

catalog_eng-html.html
background image

A2F Un-armoured, Outer Sheath Seal, “Ex d & Ex e”

A2F Flame-proof Ex d & Increased Safety Ex e Cable Gland

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X / 

II 2G Ex d II C & Ex e II  IP 66

Explosion-proof / Rain-tight / Water-tight / 

Corrosion  Resistant 

For Un-armoured 
Cables

BS 6121 : 

Part 1 : 1989

A2F
BS 6121:Part 1:1989. EN 50262:1999
ATEX II 2G Ex d IIC. Ex e II
Ex d II C. Ex e II
Retention = Class B, Impact = Level 6
-20

°

C to +80

°

C

IP66
Un-armoured
Compressed Seal
Cable Outer Sheath
Adaptor/Reducer

Model
Design Specification
ATEX Code of Protection Category
IEC Ex Code of Protection Category
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Ingress Protection Rating
Cable Type
Sealing Technique
Sealing Area(s)
Optional Accessories 

TECHNICAL DATA

Applications

A2F Type indoor and outdoor cable gland for use in Zone1, Zone2 hazardous areas with all types of Un-
armoured cable, providing mechanical cable retention and an environmental seal on the cable outer
sheath.

Features

The A2F type range of industrial cable glands is designed and tested to BS 6121:Part1:1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168: 1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

Stainless Steel 

EN10088-2:2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel 

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber ”O” ring

Standard Finishes

Brass

Natural or Nickel Plated              

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment-General 

requirements

EC 60079-1 Equipment protection by

flameproof enclosures ”d”

IEC 60079-7 Equipment protection by 

increased safety ”e”

IEC 60529 Degree of protection provided

by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe 

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where 

pressure-tight joints are not made on 
the threads

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

3.1
7.0
11.0
13.0
19.0
25.0
31.5
36.5
42.5
48.5
54.5
60.5
67.5

8.6
11.6
13.9
19.9
24.2
32.1
38.1
44.0
47.3
55.9
61.9
67.9
79.3

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

28.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

26.5
26.5
26.5
28.5
32.5
40.5
40.5
40.5
42.5
43.0
46.0
46.0
47.5

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads “C”

Standard

Option 

Metric 

NPT

NPT

Minimum 

Thread 
Length 

“E”

Overall Cable Diameter

“A” 

Across 

Flats 

“D”

Across 

Corners

Max Max 

PVC

Shroud Ref

Protrusion 

Length 

“F”

Min

Max 

Cable Glands

D24 _ D25

Cable Glands

D

Certificates

IECEx BAS 11,0061X         

Baseefa 11ATEX0135X

PG

DIN 40430:1971  PG threads

Metric

ISO 965-1, ISO 965-3 medium fit (6g) for

external threads

BS 6121 : Part 1 : 1989

catalog_eng-html.html
background image

For Armoured 
Cables

BS 6121 : 

Part 1 : 1989

CWe
BS 6121:Part 1:1989, EN 50262:1999
ATEX II 2G Ex d IIC, Ex e II
Ex d II C, Ex e II
Retention = Class B, Impact = Level 6
-20

°

C to +80

°

C

IP66
Armoured
Displacement Seal
Cable Outer Sheath

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Model
Design Specification
ATEX Code of Protection Category
IEC Ex Code of Protection Category
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Ingress Protection Rating
Cable Type
Sealing Technique
Sealing Area(s)

Optional Accessories 

TECHNICAL DATA

Applications

CWe Type indoor and outdoor cable gland for use  in Zone1, Zone2 hazardous areas with Single Wire
Armoured (SWA) Cable providing an environmental seal on the cable outer sheath, providing mechanical
cable retention and electrical continuity via armour wire termination.

Features

The CWe type range of industrial cable glands is designed and tested to BS 6121:Part 1:1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168: 1998 Grade CuZn39Pb (CW614N) (Previously BS2874 : 1986)

Stainless Steel 

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel 

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber ”O” ring            

Standard Finishes

Brass

Natural or Nickel Plated              

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment-General

requirements

IEC 60079-7 Equipment protection by

increased safety ”e”

IEC 60529 Degree of protection provided 

by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where

pressure-tight joints are not made on 
the threads

PG

DIN 40430:1971  PG threads

Metric

ISO 965-1, ISO 965-3 medium fit (6g) for

external threads

BS 6121 : Part 1 : 1989

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

8.6
11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9
79.3

8.6
12.0
15.0
20.0
26.5
33.0
39.0
45.5
52.0
58.0
64.0
71.0
78.5

13.4
15.9
20.9
27.4
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5
90.4

0.9
0.9
1.25
1.6
1.6
2.0
2.0

1.25
1.25
1.6
2.0
2.0
2.5
2.5

2.5

3.15

0.9

2.5
2.5
2.5

3.15

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

29.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

48.5
48.5
49.0
53.0
58.0
59.5
64.0
64.0
72.5
72.5
77.5
77.5
77.0

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads “C”

Standard

Option 

Metric 

NPT

NPT

Minimum 

Thread 
Length 

“E”

Armour Range 

Overall Cable 
Diameter “B”

Across 

Flats 

“D”

Across 

Corners

Min

Max Max Max 

Protrusion 

Length 

“F”

Cable

Bedding 

Diamete

“A”

PVC

Shroud

Ref

Max Min

Max 

CWe Armoured, Outer Sheath Seal, “Ex e”  

CWe Increased Safety Ex e Cable Gland

Cl. I, Div. 1 & 2, Groups A, B, C, D/ NEMA 4, 4X /

II 2G Ex d II C & Ex e II  IP 66 

Explosion-proof / Rain-tight / Water-tight / 

Corrosion Resistant 

D

Hazardous Area Type Cable Gland

Cable Glands

catalog_eng-html.html
background image

Cable Glands

D26 _ D27

For Armoured 
Cables

BS 6121 : 

Part 1 : 1989

CXe
BS 6121:Part 1:1989, EN 50262:1999
ATEX  II 2G  Ex d IIC, Ex e II
Ex d II C, Ex e II
Retention = Class B, Impact = Level 6
-20

°

C to +80

°

C

IP66
Armoured
Displacement Seal
Cable Outer Sheath

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Model
Design Specification
ATEX Code of Protection Category
IEC Ex Code of Protection Category
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Ingress Protection Rating
Cable Type
Sealing Technique
Sealing Area(s)

Optional Accessories 

TECHNICAL DATA

Applications

CXe Type indoor and outdoor cable gland for use in Zone1, Zone2 hazardous areas with all types of Wire
Braid, Strip Armour, Pliable Wire Armour & Steel Tape Armour (STA) Cable providing an environmental
seal on the cable outer sheath, providing mechanical cable retention and electrical continuity via armour
wire termination.

Features

The CXe type range of industrial cable glands is designed and tested to BS 6121:Part 1:1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168: 1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

Stainless Steel 

EN10088-2:2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel 

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber ”O” ring            

Standard Finishes

Brass

Natural or Nickel Plated              

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment-General

requirements

IEC 60079-7 Equipment protection by

increased safety ”e”

IEC 60529 Degree of protection provided 

by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where

pressure-tight joints are not made on 
the threads

PG

DIN 40430 :1971  PG threads

Metric

ISO 965-1, ISO 965-3 medium fit (6g) for

external threads

BS 6121 : Part 1 : 1989

CXe Armoured, Outer Sheath Seal, “Ex e”  

CXe Increased Safety Ex e Cable Gland

Cl. I, Div. 1 & 2, Groups A, B, C, D / NEMA 4, 4X / 

II 2G Ex d II C & Ex e II  IP 66 

Explosion-proof / Rain-tight / Water-tight / 

Corrosion Resistant 

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

8.6
11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9
79.3

8.0
12.0
15.0
20.0
26.5
33.0
39.0
45.5
52.0
58.0
64.0
71.0
78.5

13.4
15.9
20.9
27.4
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5
90.4

0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.25

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.6

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

29.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

48.5
48.5
49.0
53.0
58.0
59.5
64.0
64.0
72.5
72.5
77.5
77.5
77.0

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads “C”

Standard

Option 

Metric 

NPT

NPT

Minimum 

Thread 
Length 

“E”

Armour Range 

Overall Cable 
Diameter “B”

Across 

Flats

“D” 

Across 

Corners

Min

Max Max Max 

Protrusion 

Length

“F” 

Cable

Bedding 

Diamete

“A”

PVC

Shroud

Ref

Max Min

Max 

Cable Glands

D

catalog_eng-html.html
background image

For Armoured 
Cables

BS 6121 : 

Part 1 : 1989

E1FW
BS 6121:Part 1:1989, EN 50262:1999
ATEX II 2G Ex d IIC, Ex e II
Ex d II C, Ex e II
Retention = Class B, Impact = Level 6
-20 

°

C to +80 

°

C

IP66
Armoured
Displacement Seal
Cable Outer Sheath and lnner sheath

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Model
Design Specification
ATEX Code of Protection Category
IEC Ex Code of Protection Category
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Ingress Protection Rating
Cable Type
Sealing Technique
Sealing Area(s)

Optional Accessories 

TECHNICAL DATA

Applications

E1FW Type indoor and outdoor cable gland for use in Zone1, Zone2 hazardous areas with Single Wire
Armoured (SWA) Cable providing an environmental seal on the cable outer sheath and the cable inner
sheath , providing mechanical cable retention and electrical continuity via armour wire termination.

Features

The E1FW type range of industrial cable glands is designed and tested to BS 6121:Part 1:1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168: 1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

Stainless Steel 

EN10088-2:2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel 

BS970 Part 1 : 1996 Grade 220MO7Pb    

IP66 - Neoprene or Rubber ”O” ring            

Standard Finishes

Brass

Natural or Nickel Plated              

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment-General 

requirements

IEC 60079-1 Equipment protection by 

flameproof enclosures “d”

IEC 60079-7 Equipment protection 

by increased safety ”e”

IEC 60529 Degree of protection provided

by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe

BSPP

ISO 228/1 Pipe threads where 

pressure-tight joints are not made on the threads

PG

DIN 40430 : 1971  PG threads

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

3.1
7.0
11.0
13.0
19.0
25.0
31.5
36.5
42.5
48.5
54.5
60.5
67.5

8.6
11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9
79.3

13.4
15.9
20.9
27.4
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5
90.4

0
0
0
0
0
0
0
0
0
0
0
0
0

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

8.0
12.0
15.0
20.0
26.5
33.0
39.0
45.5
52.0
58.0
64.0
71.0
78.5

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

29.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

69.0
69.0
69.0
74.0
80.0
90.0
93.0
93.0
104.0
104.0
110.0
110.0
112.0

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads “C”

Standard

Option 

Metric 

NPT

NPT

Minimum 

Thread 
Length

“E”

Armour Range 

Overall Cable 

Diameter

“B” 

Cable Bedding 

Diameter “A”

Across 

Flats

“D” 

Across 

Corners

Min

Max Max Max 

Protrusion 

Length 

“F”

PVC

Shroud

Ref

Min

Max Max 

Min

E1FW Armoured, Outer & Inner Sheath Seal, “Ex d & Ex e”

E1FW Flame-proof Ex d & Increased Safety Ex e Cable Gland

Cl. I, Div. 1 & 2, Groups A, B, C, D/ NEMA 4, 4X / 

II 2G Ex d II C & Ex e II  IP 66 

Explosion-proof / Rain-tight / Water-tight / 

Corrosion Resistant

D

Hazardous Area Type Cable Gland

Cable Glands

Certificates

IECEx BAS 10,0057X

Baseefa 03ATEX0412X

Metric

ISO 965-1, ISO 965-3 medium fit (6g) 

for external threads threads, General purpose (Inch)

BS 6121 : Part 1 : 1989

catalog_eng-html.html
background image

E1FX
BS 6121: Part 1:1989, EN 50262:1999
ATEX  II 2G  Ex d IIC, Ex e II
Ex d II C, Ex e II
Retention = Class B, Impact = Level 6
-20 

°

C to +80 

°

C

IP66
Armoured
Displacement Seal
Cable Outer Sheath and lnner sheath

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Model
Design Specification
ATEX Code of Protection Category
IEC Ex Code of Protection Category
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Ingress Protection Rating
Cable Type
Sealing Technique
Sealing Area(s)

Optional Accessories 

TECHNICAL DATA

Applications

E1FX Type indoor and outdoor cable gland for use in Zone1, Zone2 hazardous areas with all types of Wire
Braid Armour, Strip Armour, Pliable Wire Armour & Steel Tape Armour Cable providing an environmental
seal on the cable outer sheath and the cable inner sheath , providing mechanical cable retention and
electrical continuity via armour wire termination. 

Features

The E1FX type range of industrial cable glands is designed and tested to BS 6121: Part 1:1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

Stainless Steel 

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel 

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber ”O” ring            

Standard Finishes

Brass

Natural or Nickel Plated              

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment-General

requirements

IEC 60079-1 Equipment protection by

flameproof enclosures “d”

IEC 60079-7 Equipment protection by

increased safety ”e”

IEC 60529 Degree of protection provided 

by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where

pressure-tight joints are not made on 
the threads

PG

DIN 40430 : 1971  PG threads

Metric

ISO 965-1, ISO 965-3 medium fit (6g) for

external threads

BS 6121 : Part 1 : 1989

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

10.0
10.0
10.0
10.0
10.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

3.1
7.0
11.0
13.0
19.0
25.0
31.5
36.5
42.5
48.5
54.5
60.5
67.5

8.6
11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9
79.3

13.4
15.9
20.9
27.4
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5
90.4

8.0
12.0
15.0
20.0
26.5
33.0
39.0
45.5
52.0
58.0
64.0
71.0
78.5

0.9
0.9
1.25
1.6
1.6
2.0
2.0

1.25
1.25
1.6
2.0
2.0
2.5
2.5

2.5

3.15

0.9

2.5
2.5
2.5

3.15

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

29.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

69.0
69.0
69.0
74.0
80.0
90.0
93.0
93.0
104.0
104.0
110.0
110.0
112.0

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads “C”

Standard

Option 

Metric 

NPT

NPT

Minimum 

Thread 
Length

“E”

Armour Range 

Overall Cable 
Diameter “B” 

Across 

Flats

“D” 

Across 

Corners

Min

Max Max Max 

Protrusion 

Length

“F” 

Cable

Bedding 

Diamete

“A”

PVC

Shroud

Ref

Min

Max Max 

Min

Cable Glands

D28 _ D29

Cable Glands

D

E1FX Amoured, Outer & Inner Sheath Seal “Ex d & Ex e”

E1FX Flame-proof Ex d & Increased Safety Ex e Cable Gland

Cl. I, Div. 1 & 2, Groups A, B, C, D/ NEMA 4, 4X / 

II 2G Ex d II C & Ex e II  IP 66

Explosion-proof / Rain-tight / Water-tight / 

Corrosion Resistant

For Amoured 
Cables

BS 6121 : 

Part 1 : 1989

catalog_eng-html.html
background image

E2FW Armoured, Outer & Inner Sheath Seal, Lead Sheath “Ex d & Ex e”

E2FW Flame-proof Ex d & Increased Safety Ex e Cable Gland

Cl. I, Div. 1 & 2, Groups A, B, C, D/ NEMA 4, 4X /

II 2G Ex d II C & Ex e II  IP 66 

Explosion-proof / Rain-tight / Water-tight / 

Corrosion Resistant 

For Armoured 
Cables

For Inner Lead 
Sheathed Cables

BS 6121 : 

Part 1 : 1989

E2FW
BS 6121: Part 1:1989, EN 50262:1999
ATEX  II 2G  Ex d IIC, Ex e II
Ex d II C, Ex e II
Retention = Class B, Impact = Level 6
-20 

°

C to +80 

°

C

IP66
Armoured
Displacement Seal
Cable Outer Sheath  and lnner Lead sheath

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Model
Design Specification
ATEX Code of Protection Category
IEC Ex Code of Protection Category
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Ingress Protection Rating
Cable Type
Sealing Technique
Sealing Area(s)

Optional Accessories 

TECHNICAL DATA

Applications

E2FW Type indoor and outdoor cable gland for use in Zone1, Zone2 hazardous areas with all types of Lead
She athed and Single Wire Armoured (SWA) Cable providing an environmental seal on the cable outer
sheath and the cable inner lead sheath , providing mechanical cable retention and electrical continuity via
armour wire termination.

Features

The E2FW type range of industrial cable glands is designed and tested to BS 6121:Part 1:1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

Standard Materials

Brass Extruded bar

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

Stainless Steel 

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel 

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber ”O” ring            

Standard Finishes

Brass

Natural or Nickel Plated              

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment-General

requirements

IEC 60079-1 Equipment protection by

flameproof enclosures “d”

IEC 60079-7 Equipment protection by

increased safety ”e”

IEC 60529 Degree of protection provided 

by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where

pressure-tight joints are not made on 
the threads

PG

DIN 40430:1971  PG threads

Metric

ISO 965-1, ISO 965-3 medium fit (6g) for

external threads

BS 6121 : Part 1 : 1989

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

10.0
10.0
10.0
10.0
10.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

3.1
7.0
11.0
13.0
19.0
25.0
31.5
36.5
42.5
48.5
54.5
60.5
67.5

8.6
11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9
79.3

13.4
15.9
20.9
27.4
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5
90.4

8.0
12.0
15.0
20.0
26.5
33.0
39.0
45.5
52.0
58.0
64.0
71.0
78.5

0.9
0.9
1.25
1.6
1.6
2.0
2.0

1.25
1.25
1.6
2.0
2.0
2.5
2.5

2.5

3.15

0.9

2.5
2.5
2.5

3.15

25.0
28.0
30.0
40.0
48.0
55.0
60.0
70.0
75.0
80.0
90.0
100.0
120.0

29.0
31.0
33.0
44.0
53.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

69.0
69.0
69.0
74.0
80.0
90.0
93.0
93.0
104.0
104.0
110.0
110.0
112.0

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads “C”

Standard

Option 

Metric 

NPT

NPT

Minimum 

Thread 
Length

“E”

Armour Range 

Overall Cable 
Diameter “B”

Across 

Flats 

“D”

Across 

Corners

Min

Max Max Max 

Protrusion 

Length 

“F”

Cable

Bedding 

Diamete

“A”

PVC

Shroud

Ref

Min

Max Max 

Min

D

Hazardous Area Type Cable Gland

Cable Glands

catalog_eng-html.html
background image

For Un-armoured 
Cables

BS 6121 : 

Part 1 : 1989

SS2K
BS 6121:Part 1:1989, EN 50262:1999
ATEX II 2G Ex d IIC, Ex e II
Ex d II C, Ex e II
Retention = Class B, Impact = Level 6
-20 °C to +80 °C

IP66
Un-armoured
Displacement Seal
Cable Outer Sheath and lnner sheath

Adaptor/Reducer, Earth Tag, 
Serrated Washer, Shroud

Model
Design Specification
ATEX Code of Protection Category
IEC Ex Code of Protection Category
EN 50262 Mechanical Classifications
Continuous Operating Temperature

Ingress Protection Rating
Cable Type
Sealing Technique
Sealing Area(s)

Optional Accessories 

TECHNICAL DATA

Applications

SS2K Type indoor and outdoor cable gland for use in Zone1, Zone2 hazardous areas with all types of Un-
armour ed cable, providing mechanical cable retention and an environmental seal on the cable outer
sheath and the cable inner sheath.

Features

The SS2K type range of industrial cable glands is designed and tested to BS 6121:Part1:1989
All metallic cable gland components are manufactured from the same grade of material. Brass locknuts
are produced in the same CU Zn39PB3 grade as the cable gland.

A

E

F

B

D

C

Standard Materials

Brass Extruded bar

EN12168 : 1998 Grade CuZn39Pb (CW614N) (Previously BS2874: 1986)

Stainless Steel 

EN10088-2 : 2005 Grade 316L (Previously BS970 Part 1 : 1991)

Mild Steel 

BS970 Part 1 : 1996 Grade 220MO7Pb

IP66 - Neoprene or Rubber ”O” ring            

Standard Finishes

Brass

Natural or Nickel Plated         

Mild Steel

Electro Zinc Plated

Compliances / Approvals

IEC 60079-0 Equipment-General 

requirements

IEC 60079-1 Equipment protection by 

flameproof enclosures “d”

IEC 60079-7 Equipment protection by 

increased safety ”e”

IEC 60529 Degree of protection provided 

by enclosures (IP Code)

NPT

ANSI / ASME B 1.20.1 Pipe 

threads, General purpose (Inch)

BSPP

ISO 228/1 Pipe threads where 

pressure-tight joints are not made on the threads

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90

1/2"
1/2"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
2"
2 1/2"
2 1/2"
3"
3"

3/4"
3/4"
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
2 1/2"
3"
3"
3 1/2"
3 1/2"

15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0

3.1
7.0
11.0
13.0
19.0
25.0
31.5
36.5
42.5
48.5
54.5
60.5
67.5

8.6
11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9
79.3

26.0
30.0
32.0
44.0
51.0
61.0
67.0
77.0
82.0
88.0
99.0
110.0
132.0

51.5
53.5
54.0
63.0
67.5
80.0
80.0
81.0
80.0
82.5
89.5
89.5
94.0

GPS20
GPS20
GPS20
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

Cable Gland Selection Table

20S/16

20S

20
25
32
40

50S

50

63S

63

75S

75
90

Cable

Gland Size

Available Entry Threads “C”

Standard

Option 

Metric 

NPT

NPT

Minimum 

Thread 
Length

“E”

Overall Cable 

Diameter  “B”

Cable Bedding 

Diamete “A”

Across 

Corners

Max Max 

Protrusion 

Length 

“F”

PVC

Shroud Ref

Min

Min

Max 

SS2K Un-armoured, Outer & Inner Sheath Seal “Ex d & Ex e”

SS2K Flame-proof Ex d & Increased Safety Ex e Cable Gland

Cl. I, Div. 1 & 2, Groups A, B, C, D/ NEMA 4, 4X /

II 2G Ex d II C & Ex e II  IP 66

Explosion-proof / Rain-tight / Water-tight / 

Corrosion Resistant 

Cable Glands

D30 _ D31

Cable Glands

D

Certificates

IECEx BAS 11,0061X              

Baseefa HATEX0135X

PG

DIN 40430:1971  PG threads

Metric

ISO 965-1, ISO 965-3 medium 

fit (6g) for external threads

BS 6121 : Part 1 : 1989

3.1
7.0
11.0
13.0
19.0
25.0
31.5
36.5
42.5
48.5
54.5
60.5
67.5

8.6
11.6
13.9
19.9
26.2
32.1
38.1
44.0
49.9
55.9
61.9
67.9
79.3

catalog_eng-html.html
background image

M20
M25
M32
M40
M50
M63
M75
M90

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

28.5
35.8
43.5
52.2
64.0
77.5
90.0
106.0

M6
M6
M10
M13
M13
M13
M13
M13

55.0
61.5
76.0
92.0
111.0
128.7
141.3
165.0

33.8
36.6
44.3
53.9
67.0
78
84.3
100

Reference 

Cable Entry Size

Minimum 

Thickness

Nominal 

Collar Diameter

Earth Link Conn

-ection Hole Size

Nominal

Length

Nominal

Centers

Applications

Earth Tags (Slip type) installed between the cable gland and equipment, provide an earth bond connection
as spe cified in BS 6121:Part5:1993.

BS 6121 : 

Part 1 : 1989

Metric Earth Tags

1/2" NPT
3/4" NPT
1" NPT
1-1/4" NPT
1-1/2" NPT
2" NPT
2-1/2" NPT
3" NPT
4" NPT

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

28.5
35.8
43.5
52.2
64.0
77.5
90.0
90.0
106.0

M6
M6
M10
M13
M13
M13
M13
M13
M13

55.0
61.5
76.0
92.0
111.0
128.7
141.3
141.3
165.0

33.8
36.6
44.3
53.9
67.0
78
84.3
84.3
100

Reference 

Cable Entry Size

Minimum 

Thickness

Nominal 

Collar Diameter

Earth Link Conn

-ection Hole Size

Nominal

Length

Nominal

Centers

NPT Earth Tags

Earth Tags

To maintain the Ingress Protection rating between
the equipment and cable gland it may be necessary
to fit an Entry Thread Seal at the gland entry
interface. For Explosion Protected equipment it is
essential to maintain the integrity of the degree of
Ingress Protection at which the equipment has been
rated. The need for a sealing washer will very much
depend on the Ingress Protection rating and code of
protection of the equipment and the type of entry
holes available within that equipment.

M16
M20
M25
M32
M40
M50
M63
M75
M90

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

26.0
26.0
35.0
42.0
49.0
62.0
75.0
87.0
102.0

1/2" NPT
3/4" NPT
1" NPT
1-1/4 NPT
1-1/2" NPT
2" NPT
2-1/2" NPT
3" NPT

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

28.0
35.0
42.0
49.0
62.0
75.0
87.0
102.0

Reference 

Diameter

Minimum

Thickness

External

Diameter

Reference 

Diameter

Minimum

Thickness

External

Diameter

Metric Entry Thread Seal

NPT Entry Thread Seal

Entry Thread Seal

D

Accessories

Cable Glands

catalog_eng-html.html
background image

Applications

16
20S/16
20S
20
25S
25
32
40
50S
50
63S
63
75S
75
90

-
-

GPS20
GPS20
GPS25
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
-

GPS16
GPS20
GPS20
GPS20
GPS25
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

GPS16
GPS20
GPS20
GPS20
GPS25
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

-

GPS20
GPS20
GPS20
GPS25
GPS25
GPS32
GPS40
GPS50
GPS50
GPS63
GPS63
GPS75
GPS75
GPS90

Cable Gland Size

Shrouds for BW 

Cable Gland Group

Shrouds for CW 

Cable Gland Group

Shrouds for A2 

Cable Gland Group

Shrouds for E1W 

Cable Gland Group

SAMWHA manufactures a range of push on shrouds which are used to minimize the risk of dirt or foreign
substances gathering on the Cable Gland body, and/or point of cable to cable gland interface

Shroud

Brass Locknuts are the recommended items used
in securing brass cable glands, unions, adaptors,
reducers, and stopper plugs to a gland plate or into
equipment.
Zinc Plated Mild Steel locknuts are a cost effective
alternative to brass locknuts and should only be
used in dry, low humidity conditions.

M16 x 1.5
M20 X 1.5
M25 X 1.5
M32 X 1.5
M40 X 1.5
M50 X 1.5
M63 X 1.5
M75 X 1.5
M90 X 2.0

5
5
5
5
7
7
7
7
7

27.5
33.0
38.0
45.0
56.0
65.0
77.0
94
132

25.0
30.0
35.0
40.0
50.0
60.0
70.0
85.0
120.0

Thread 

Diameter “A”

Minimum
Thickness

Across Flats 

Dimension “B”

Across Corners 

Diameter “C” 

Metric Lock-Nuts

NPT Lock-Nuts

Lock-Nuts

1/2" NPT
3/4" NPT
1" NPT
1-1/4" NPT
1-1/2" NPT
2" NPT
2-1/2" NPT
3" NPT
4" NPT

5
5
5
5
7
7
7
7
7

27.5
38.0
45.0
56.0
65.0
77.0
94
112
132

25.0
35.0
40.0
50.0
60.0
70.0
85.0
100.0
120.0

Thread 

Diameter “A”

Minimum
Thickness

Across Flats 

Dimension “B” 

Across Corners 

Diameter “C”

Cable Glands

D32 _ D33

Cable Glands

D

catalog_eng-html.html
background image

Outstanding Tensile and Compressive Strength are 
the Best Brands in Korea

KS and UL listed Samwha's conduits system fully protect cables under any work environment. 

In fact, our flexible conduits that feature tensile and compressive strength are the best brands in

Korea. They are widely used in shipbuilding (LNG carriers), offshore plants, industrial machinery

and machine tools, railroads, power plants and cars.    

catalog_eng-html.html
background image

Smart  +  Technology  +  Human

E

E

Electrical Conduit
Systems/Cable Trays

Contents

Electrical Conduit System / Cable Trays

Rigid Conduits

Flexible & Pliable Metal Conduits

Fitting for Pliable Metal Conduits

Fitting for Rigid Non-Matel PVC & HI-PVC Conduits

Fitting for Flexible & Pliable Metal Conduits Non-liquid
Tight Fittings

Fitting for Flexible & Pliable Metal Conduits Liquid 
Tight Fittings

Fitting for Flexible & Pliable Metal Conduits The Others

Fitting for Flexible & Pliable Metal Conduits Accessory 

Cable Trays Ladder Series

E10

E15

E31

E36

E38

E40

E45

E47

E50

catalog_eng-html.html
background image

Features

An electrical conduit is an electrical piping system used for protection and routing of electrical wiring.
Electrical conduit may be made of metal, plastic, fiber, or fired clay. Flexible conduit is available for
special purposes.

Conduit is generally installed by electricians at the site of installation of electrical equipment. 
Its use, form, and installation details are often specified by wiring regulations, such as the U.S. NEC or
other national or local code. The term "conduit" is commonly used by electricians to describe any system
that contains electrical conductors, but the term has a more restrictive definition when used in wiring
regulations.

Early electric lighting installations made use of existing gas pipe to gas light fixtures
(converted to electric lamps). Since this technique provided very good protection for interior wiring, 
it was extended to all types of interior wiring

RMC

RNC

GRC

EMT

ENT

FMC

LFMC

LFNC

IMC

PVC condui

AL conduit

(Coated, Heavy)

-

(Galvanized, Heavy)

(Galvanized, Thin)

-

(Thin)

(Thin)

-

(Galvanized, Middle)

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Metallic

Allow to be threaded

Flexible or Pliable

Liquid tight

Conduit Performance Selection Table

Comparison with other Wiring Methods 

Electrical conduit provides very good protection to enclosed conductors from impact, moisture, and
chemical vapors. Varying numbers, sizes, and types of conductors can be pulled into a conduit, which
simplifies design and construction compared to multiple runs of cables or the expense of customized
composite cable. Wiring systems in buildings are subject to frequent alterations. Frequent wiring
changes are made simpler and safer through the use of electrical conduit, as existing conductors can be
with drawn and new conductors installed, with little disruption along the path of the conduit. 
A conduit system can be made waterproof or submersible. Metal conduit can be used to shield sensitive
circuits from electromagnetic in-terference, and also can prevent emission of such interference from
enclosed power cables. When installed with proper sealing fittings, a conduit will not permit the flow of
flammable gases and vapors, which provides protection from fire and explosion hazard in areas handling
volatile substances. Some types of conduit are approved for direct encasement in concrete. 
This is commonly used in commercial buildings to allow electrical and communication outlets to be
installed in the middle of large open areas. For example, retail display cases and open-office areas use
floor-mounted conduit boxes to connect power and communications cables. 

E

Electrical Conduit System /
Cable Trays

catalog_eng-html.html
background image

Both metal and plastic conduit can be bent at the job site to allow a neat installation without ex-cessive
numbers of manufactured fittings. This is particularly advantageous when following irregular or curved
building profiles. The cost of conduit installation is higher than other wiring methods due to the cost of
materials and labor. In applications such as residential construction, the high degree of physical damage
protection is not required so the expense of conduit is not warranted. Conductors installed within conduit
cannot dissipate heat as readily as those installed in open wiring, so the current capacity of each con-
ductor must be reduced if many are installed in one conduit. It is impractical, and prohibited by wiring re-
gulations, to have more than 360 degrees of total bends in a run of conduit, so special outlet fittings must
be provided to allow conductors to be installed without damage in such runs. 
While metal conduit can be used as a grounding conductor, the circuit length is limited. A long run of
conduit as grounding conductor will not allow proper operation of overcurrent devices on a fault.

Types of Conduit 

Conduit systems are classified by the wall thickness, mechanical stiffness, and material used to make the tubing.

Rigid Metal Conduit (RMC) is a thick threaded 
tubing, usually made of coated steel, stainless 
steel or aluminum.

Rigid Metal Conduit (RNC) is a thick threaded 
tubing.

Rigid Metal Conduit (RMC)

Rigid Nonmetallic Conduit (RNC)

Galvanized rigid conduit (GRC) is galvanized steel
tubing, with a tubing wall that is thick enough to 
allow it to be threaded. Its common applications 
are in commercial and industrial construction.

Galvanized Rigid Conduit (GRC)

Electrical Nonmetallic Tubing (ENT) is a thin-walled 
corrugated tubing that is moisture-resistant and 
flame retardant. It is pliable such that it can be bent
by hand and is often flexible although the fittings
are not. It is not threaded due to its corrugated
shape although the fittings might be.

Electrical Nonmetallic Tubing (ENT)

Flexible Metallic Conduit (FMC) is made through the 
coiling of a self-interlocked ribbed strip of aluminum 
or steel, forming a hollow tube through which wires 
can be pulled. FMC is used primarily in dry areas 
where it would be impractical to install EMT or 
other non-flexible conduit, yet where metallic
strength to protect conductors is still required. 
The flexible tubing does not maintain any permanent 
bend. Cutting FMC requires a specialized hand tool 
with a rotary abrasive disc to creates a small incision 
into the ribbing so that a twisting motion separates
the segments. 
The disc cuts deep enough to sever the armor coil
but not so deep that it could damage the inside
conductors. Short segments of FMC called ''whips'' 
are often used as circuit "pigtails" between fixtures 
and a [junction box], especially in [suspended 
ceiling]s. Whip assemblies save a great deal of
repetitive labor when installations require several
pigtails for several fixtures.
Flexible metal conduit coated with a UV-resistant 
polymer is liquid-tight when installed with appropriate
[Gland (engineering)|glandular] fittings containing 
liquid-tight features such as [O-ring]s.
Wiring regulations vary; in locales following the U.S. 
[National Electrical Code | National Electric Code]
(NEC), flexible metallic conduit may serve as an 
equipment-grounding conductor. Other areas
may require a bonding wire for equipment grounding.
The bonding wire in direct contact with the interior
of the conduit creates a lower resistance grounding
conductor than the conduit alone.

Flexible Metallic Conduit (FMC)

Electrical metallic tubing (EMT), sometimes 
called thin-wall, is commonly used instead of 
galvanized rigid conduit (GRC), as it is less costly
and lighter than GRC. EMT itself may not be 
threaded, but can be used with threaded fittings 
that clamp to it. Lengths of conduit are connected 
to each other and to equipment with clamp-type 
fittings. Like GRC, EMT is more common in 
commercial and industrial buildings than in 
residential applications. EMT is generally made of
coated steel, though it may be aluminum.

Electrical Metallic Tubing (EMT)

Electrical Conduit / Cable Trays

E2 _ E3

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

Features

Liquid-tight Flexible Metal Conduit (LFMC) is a metallic flexible conduit covered by a waterproof 
plastic coating. The interior is similar to FMC.

Flexible Metallic Tubing (FMT) is not the same as Flexible Metallic Conduit (FMC) aka "greenfield" or "flex" 
which is National Electrical Code (NEC) Art 348. FMT is a raceway, but not a conduit and is a separate NEC 

Article - 360. It only comes in 1/2" & 3/4" trade sizes whereas FMC is sized 1/2" ~ 4" trade sizes. NEC 360.2
describes it as: "A raceway  that is circular in cross section, flexible, metallic and liquid-tight without a 

nonmetallic jacket."

Liquid-tight Flexible Metal Conduit (LFMC)

Flexible Metallic Tubing (FMT)

Liquid-tight Flexible Nonmetallic Conduit (LNFC) refers to several types of flame-resistant non-metallic tubing. 
Interior surfaces may be smooth or corrugated. Theremaybeintegralreinforcement withinthe conduit wall. 
It is also known as FNMC.

Liquid-tight Flexible Nonmetallic Conduit (LFNC)

Intermediate Metal Conduit (IMC) is a steel tubing heavier than EMT but lighter than RMC. It may be threaded.

Intermediate Metal Conduit (IMC)

PVC conduit is the lightest in weight compared to  other conduit materials, and usually lower in cost than other
forms of conduit.  In North American electrical practice, it is available in three different wall  thicknesses, with
the thin-wall variety only suitable for embedded use in concrete, and heavier grades suitable for direct burial and 
exposed work. The various fittings made for metal conduit are also made for PVC. The  plastic material resists
moisture and many corrosive substances, but since the tubing is non-conductive an extra bonding (grounding) 
conductor must be pulled into each conduit. PVC conduit may be heated and bent in the field. Joints to fittings are
made with slip-on solvent-welded connection, which set up rapidly after assembly and attain full  strength in about 
one day. Since slip-fit sections do not need to be rotated during assembly,  the special union fittings used with 
threaded conduit (Ericson) are not required. Since PVC conduit has a higher  thermal coefficient of expansion than 
other types, it must be mounted so as to allow for expansion and  contraction of each run. Care should be taken 
when installing PVC underground in multiple or parallel run con-figurations due to mutual heating effect of cable.

PVC Conduit

Aluminum conduit, similar to galvanized steel  conduit, is a rigid conduit, generally used in commercial and 

industrial applications,  where a higher resistance to corrosion is needed.  Such locations would include food 
processing plants, where large amounts of water and cleaning chemicals would make galvanized conduit

unsuitable. Aluminum cannot be directly embedded in concrete, since the metal reacts with the alkalis in cement. 

The conduit may be coated to prevent corrosion by incidental contact with concrete. The extra cost of aluminum 
is somewhat offset by  the lower labor cost to install, since a length of aluminum conduit will have about one-
third the weight of an equally-sized rigid steel conduit.

Aluminum Conduit

In extreme corrosion environments where plastic coating of the tubing is insufficient, conduits may be 
made from stainless steel, bronze or brass.

Other Metal Conduits

Large diameter (more than 2 inch/50 mm) conduit  may be installed underground between buildings to allow
installation of power and communication cables. An assembly of these  conduits, often called a duct bank, 
may either be directly buried in earth or encased in concrete. A duct bank will allow replacement of 
damaged cables between buildings or additional power and communications circuits to be added, without 
the expense of ex-cavation of a trench. While metal conduit is occasionally used for burial, usually PVC, 
pol-yethylene or polystyrene plastics are now used due to lower cost. Formerly, compressed asbestos fiber 
mixed with cement was used for some underground installations.Telephone and com-munications circuits 
were installed in fired-clay conduit.

Underground Conduit

Types of Conduit 

E

Electrical Conduit System /
Cable Trays

catalog_eng-html.html
background image

Electrical Conduit / Cable Trays

E4 _ E5

Comparison of Some Types of Conduit

Exact ratios of installation labor, weight and material cost vary depending on the size of conduit, but the
values for 3/4 inch (21 metric) trade size are representative.

Relative to rigid galvanized steel conduit, 3/4 inch (21 metric) size

It’s appearance may not be acceptable to all observers.

Disadvantages

- It allows one to add new wiring to an existing building without removing or cutting holes into 

thedrywall or lath and plaster.

- It allows circuits to be easily locatable and accessible for future changes thus enabling 

minimum effort upgrades.

Advantages

The term TRUNKING is used in the United Kingdom for electrical wire-ways , generally rectangular in 
cross section with removable lids. Mini TRUNKING is a term used in the UK for small form-factor 
(usually 6mm to 25mm square or rectangle sectioned) PVC wire ways. In North American practice 

wire trough

or 

lay-in wire-ways

are terms used to designate similar products, but these are never 

used enclosed in masonry or a wall.

Trunking

Labor

Weight

Material cost

1.0

1.0

1.0

0.89

0.34

0.99

0.89

0.76

0.84

0.62

0.42

0.35

0.55

0.20

0.43

Relative

RGS

IMC

EMT

PVC

Aluminum

Other Wire-ways

This type of "decorative" conduit is designed to provide an aesthetically acceptable passageway for wiring 
without hiding it inside or behind a wall. This is used where additional wiring is required, but where going 
through a wall would be difficult or require remodeling. The conduit has an open face with removable cover, 
secured to the surface, and wire is placed inside. Plastic raceway is often used for telecommunication wiring, 
such as network cables in an older structure, where it is not practical to drill through concrete block.

Surface Mounted Raceway (wire molding) 

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

Technical tip for Electrical Wiring

Electrical wiring in North America follows regulations and standards for installation of building wiring. Electrical
wiring in the United States is generally in compliance with the National Electrical Code, a standard sponsored by
the National Fire Protection Association which has been periodically revised since 1897. Local amendments or
supplements to this model code are common in American cities or states. For electrical wiring in Canada, 
the Canadian Electrical Code is a very similar standard published in Canada by the Canadian Standards
Association since 1927. Other countries neighboring the U.S. also usually use the same standards, including
much of Mexico.

Although much of the electrician's field terminology matches that of the electrical codes, usages can vary.

- A neutral wire is the return leg of a circuit; in building wiring systems the neutral wire is connected  to

earth ground at least at one point. North American standards state that the neutral is neither switched 
nor fused. The neutral is connected to the center tap of the power company transformer of a split-phase

system, or the center of the wye connection of a poly-phase power system. American electrical codes require   

that the neutral be connected to earth at the "service panel" only and at no other point within the building 

wiring system. Formally the neutral is called the "grounded conductor"; as of the 2008 defined in the 

Code to record what had been common usage.

- Hot is any conductor (wire or otherwise) connected with an electrical system that has electric potential

to electrical ground or neutral.

- Grounded is a conductor with continuity to earth.

- Leg as in 'hot leg' refers to one of multiple hot conductors in an electrical system. The most common

service in the U.S., single split-phase, 240 V, features a neutral and two hot legs, 240 V to each other, 
and 120 V each to the neutral. A three-phase system will have three "hot" legs.

- An outlet is called a receptacle in the NEC. In the NEC an outlet is a device for easily connecting a  utilization 

device by inserting a mating plug.

Terminology

Electrical Codes and Standards

The National Electrical Code (NEC) specifies acceptable wiring methods and materials. Local jurisdictions
usually adopt the NEC or another published code and then distribute documents describing how local
codes vary from the published codes. They cannot distribute the NEC itself for copyright reasons.
The purpose of the NEC is to protect persons and property from hazards arising from the use of
electricity. The NEC is not any jurisdiction's electrical code per se; rather, it is an influential work of
standards that local legislators (e.g., city council members, state legislators, etc. as appropriate) tend to
use as a guide when enacting local electrical codes. The NFPA states that excerpts quoted from the
National Electrical Code must have a disclaimer indicating that the excerpt is not the complete and au-
thoritative position of the NFPA and that the original NEC document must be consulted as the definitive
reference.New construction, additions or major modifications must follow the relevant code for that
jurisdiction, which is not necessarily the latest version of the NEC. Regulations in each jurisdiction will
indicate when a change to an existing installation is so great that it must then be rebuilt to comply with the
current electrical code. Generally existing installations are not required to be changed to meet new codes.
Enforcement of code requirements varies by jurisdiction in the United States. In many areas, a
homeowner, for example, can perform household wiring for a building which the owner occupies; this
may even be complete wiring of a home. A few cities  have more restrictive rules and require electrical
installations to be done by licensed electricians. The work will be inspected by a designated authority at
several stages before permission is obtained to energize the wiring from the local electric utility; the
inspector may be an employee of the state or city, or an employee of an electrical supply utility.

For residential wiring, some basic rules given in the NEC are:

- Phase wire in a circuit may be black, red, orange (high leg delta) insulated wire, sometimes other colors, 

but never green, gray, or white (whether these are solid colors or stripes). Specific exceptions apply, such 

as a cable  running to a switch and back (known as a traveler) where the white wire will be the hot wire feeding 

that switch. Another is for a cable used to feed an outlet for  250VAC 15 or 20 amp appliances that do not 

need a neutral, there the white is hot (but should be identified as being hot, usually with black tape inside
junction boxes).

Design and Installation Conventions

E

Electrical Conduit System /
Cable Trays

catalog_eng-html.html
background image

Electrical Conduit / Cable Trays

E6 _ E7

- The neutral wire is identified by gray or white insulated wire, perhaps with stripes.

- Grounding wire of circuit may be bare or identified insulated wire of green or having green stripes. Note

that all metallic systems in a building are to be bonded to the building grounding system, such as water, 

natural gas, HVAC piping, and others.

- Larger wires are furnished only in black; these may be properly identified with suitable paint or tape.

- All wiring in a circuit except for the leads that are part of a device or fixture must be the same gauge. Note that

different size wires may be used in the same raceway so long as they are all insulated for the max-imum voltage of 

any of these circuits.

- The Code gives rules for calculating circuit loading.

- Ground-fault circuit interrupter (GFCI) protection is required on receptacles in wet locations.This includes all small 

appliance circuits in a kitchen, receptacles in a crawl space, basements, bathrooms and a  receptacle for the
laundry room, as well as outdoor circuits within easy reach of the ground. However, they are not required for 
refrigerators because unattended disconnection could cause spoilage of food, nor for garbage disposals. Instead, 

for refrigerators and other semi-permanent appliances in basements and wet areas, use a one-outlet non-GFCI 
dedicated receptacle. Two-wire outlets having no grounding conductor may be protected by an upstream

gfci and must be labeled "no grounding". Most GFCI receptacles allow the connection and have GFCI protection for 

down-stream connected receptacles. Receptacles protected in this manner should be labeled "GFCI protected".

- Most circuits have the metallic components inter-connected with a grounding wire connected to the third, round

prong of a plug, and to metal boxes and appliance chassis. 

- Furnaces, water heaters, heat pumps, central air conditioning units and stoves must be on dedicated circuits.

- The code provides rules for sizing electrical boxes for the number of wires and wiring devices in the box.

- The foregoing is just a brief overview and must not be used as a substitute for the actual National 

Electrical Code.

Electrical wiring practices developed in parallel  in many countries in the late 19th and early 20th centuries . 

As a result, national and regional variations developed and remain in effect. (see National Electrical Code, 
electrical wiring, electrical wiring in the United Kingdom). Some of these are retained for technical reasons, 
since the safety of wiring systems depends not only on the wiring code but also on the technical standards 
for wiring devices, materials, and equipment. Grounding (earthing) of distribution circuits is a notable 
difference in practice between United States wiring systems and those elsewhere in the world. Since the 
early 1960s, wiring in new construction has required a separate grounding conductor used to bond

(electrically connect) all normally non-current carrying parts of an electrical installation. Portable appliances

with metal cases also have a bonding conductor in the flexible cable and plug connecting them to the 
distribution system. The circuit return conductor (neutral) is also connected to ground at the service

entrance panel only; no other connections from neutral to ground are allowed, unlike regulations in other
parts of the world. Lighting and power receptacle circuits in North American systems are typically radial 
from a distribution panel containing circuit breakers to protect each branch circuit.The smallest branch
circuit rating is 15 amperes, used for general purpose receptacles and lighting. In residential construction, 

branch circuits for higher ratings are usually dedicated to one app-liance, for example, fixed cooking

appliances, electric clothes dryers, and air conditioners. Lighting and general purpose receptacles are at
120 volts AC, with larger devices fed by three wire single-phase circuits at 240 volts. In commercial
construction, three-phase circuits are used. Generally, receptacles are fed by 120 V or 208 V (in place of 
240 V in a house), and can include special amperage rated outlets for industrial equipment. Lighting is
usually fed by 277 V (with exception for special-use lights that use 120 V). Equipment can be hard-wired
into the building using either 120/208 V or 277/480 V. Countries such as Mexico may adopt the NFPA 
standard as their national electrical code, with local amendments similar to those in United States
jurisdictions. The Canadian Electrical Code, while developed independently from the NFPA code, is similar
in scope and intent to the US NEC, with only minor variations in technical re-quirement details; harmonization
of the CSA and NEC codes is intended to facilitate free trade between the two countries.

Comparison of US Practices with other Countries

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

Technical tip for Electrical Wiring

In Class I, Division 1, locations, all conduit must be rigid metal or steel IMC with at least five full tapered threads

tightly engaged in the enclosure. (An exception to 500.8(E) allows 4-1/2 for factory threaded NPT entries.)

All factory-drilled and tapped SAMWHA enclosures satisfy this requirement. When field drilling  and tapping 

is performed it may be required to drill and tap deeper than standard NPT to insure engagement of five full
threads. For further information contact your SAMWHA field representative. A common method of wiring

employs thick-walled conduit with a corrosion-resistant finish. In addition to the protective finish on the conduit, 

various types of paints or special finishes are used extensively to give extra protection from corrosive atmospheres. 

Alternate changes in temperature and barometric pressure cause“breathing” — the entry and circulationof air 

throughout  the conduit. As joints in a conduit system and its components are seldom tight enough to prevent this 

breathing, moisture in the air condenses and collects at the base of vertical conduit runs and equipment enclosures. 

This could cause equipment shorts or grounds.To eliminate this condition, inspection fittings should be installed 
and equipped with Explosion-proof drains to automatically drain off the water.

Conduit.

Wiring Methods

NEC 501.15 requires that sealing fittings filled with approved compound be installed in conduits entering explosion-proof 
enclosures. Seals are necessary to limit volume, to prevent an explosion from traveling throughout the conduit system,
to block gases or vapors from moving from a hazardous to a nonhazardous area through connecting raceways or from
enclosure to enclosure, and to stop pressure piling - the buildup of pressure inside conduit lines caused by pre-
compression as the explosion travels through the conduit. (See Appendix III - Selection of Seals and Drains.)

The standard type seals are not intended to prevent the passage of liquids, gases or vapors at pressures
continuously above atmospheric.

Temperature extremes and highly corrosive liquids and vapors may affect the ability of seals to perform their 
intended function.In hazardous locations, seals are needed in the following instances:

- Where the conduit enters an enclosure that houses arcing or high-temperature equipment. (A seal must 

be within 18 inches or closer if the manufacturer’s instructions so specify of the enclosure it isolates.)

- Where the conduit enters enclosures that house terminals, splices or taps, if the conduit is 2-inch trade 

size or larger.

- Where the conduit leaves a Division I area or passes from a Division 2 hazardous area to a nonhazardous 

location. 

Seals for Conduit System.

Another type of wiring system suitable for Division 1 is mineral insulated (MI) cable. Mineral-insulated wiring consists 
of copper conductors properly spaced and encased in tightly compressed magnesium oxide, clad in an overall copper 
sheath.Below the melting temperature of the copper sheath, MI cable is impervious to fire. Because of limitations
on end connections, its operating range is generally considered to be -40 to 80°C with standard terminals, and up
to 250°C with special terminals. When properly installed, MI cable is suitable for all Class I and Class II locations.

MI cable is available with one to 17 conductors, making it most suitable for wiring of control boards, control components 
and instrumentation circuits where crowded conditions make conduit installations difficult and expensive.

MI cable is hygroscopic; therefore, moisture can be a problem when the ends are left exposed. Care must be taken 
to install and seal the end fittings as soon as possible to prevent moisture accumulation. If moisture enters, the end 
must be cut off or dried out with a torch.

Mineral Insulated Cable.

E

Electrical Conduit System /
Cable Trays

catalog_eng-html.html
background image

Electrical Conduit / Cable Trays

E8 _ E9

Metal-clad cable (Type MC) is permitted by the
National Electrical Code for application in Class I,
Division 2 locations.

Use of this type of cable is not limited to any voltage
class. The armor itself is available in various metals.
When further protection from chemical attack is
needed, a supplemental protective jacket may be used.

The NEC also permits, under certain restrictions, 
a particular kind of metal-clad cable (MC-HL) to be
used in Class I, Division 1 locations. This is detailed in
501.10(A)(1)(c). Similarly, 501.10(A)(1)(d) permits a
certain type of Instrumentation Tray Cable (ITC-HL).

Metal-Clad Cable.

Power and control tray cable (Type TC) is permitted in
Class I, Division 2 locations. It is a factory assembly of
two or more insulated conductors with or without the
grounding conductor under a nonmetallic sheath.

Tray Cable.

In Class I, Division 1 locations the use of cable, except
types MI, MC-HL and ITC-HL, is limited to installation
in conduit.

Multi-conductor cables that cannot transmit gases
through the cores are sealed as single conductors; this
type of cable, however, is not readily available. If a
cable can transmit gases through its core, the outer
jacket must be removed so that the sealing compound
surrounds each individual insulated conductor and the
jacket, or it can be sealed as a single conductor if the
cable end in the enclosure is sealed by an approved
means. SAMWHA epoxy is such a means.

In Class I, Division 2 locations cables must be sealed
where they enter enclosures required to be explosion-
proof. 

In the case of extra-hard-usage flexible cord, SHF or
SVF seals with appropriate cable terminators are
recommended. If the cable core can transmit gases,
the outer jacket must be removed so that the sealing
compound surrounds each conductor to prevent the
passage of gases.

Cables without a gas-tight continuous sheath must be
sealed at the boundary of the Division 2 and unclassified
locations.

If attached to equipment that may cause a pressure at
a cable end, a sheathed cable that can transmit gases
through its core must be sealed to prevent migration of
gases into an unclassified area.

G. Cable Sealing.

In Class I, Division 2 locations, the NEC also recognizes
the use of Type PLTC, similar to TC except the con-
ductors are limited to No. 22 through No. 16; also Type
MV, a single or multi-conductor solid dielectric
insulated cable rated 2001 volts or higher. The NEC
also permits Type ITC cable, as covered by Article 727,
Instrumentation Tray Cable, which details its con-
struction and use.

Other Permitted Cables.

Under certain restrictions, in Class I, Division 2
locations, reinforced thermosetting resin conduit
(RTRC) and Schedule 80 PVC conduit and associated
fittings may be used.

Nonmetallic Conduit

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

KS C 8401 & JIS C 8305 

Intermediate Metal Conduit (IMC)

Remarks The following Standards are cited in this Standard

KS B 0023 Screw Threads for Rigid Metal Conduits and Fittings

KS D 0201 Methods of Test for Hot Dip Galvanized Coatings

KS D 3512 Cold Rolled Carbon Steel Sheets and Strip

KS D 3555 Hot Rolled Carbon Steel Strip for Pipes  and Tubes

KS D 9502 Methods of Neutral Salt Spray Testing

Type 

Conduit tubes are classified into three types of thick rigid steel conduit tubes, 
thin rigid steel conduit tubes and thread-less rigid steel conduit tubes.

Bending Performance

When a conduit tube is subjected to the test of 9.1, the variation in outside diameter shall 
be 

±

20% of the original outside diameter, and no separation or split of the welded seam 

shall take place and no crack or peeling off shall develop on the galvanized surface or coated film.

Corrosion-resistance

The rust prevention given to conduit tubes shall comply with the relevant items described below.

a) The surface treated by galvanizing or thermal spraying shall not reach the 

end point when subjected to the uniformity test of 9.2.1.

b) No white corrosion product shall be produced on the surface electrically galvanized and chromate, 

when the salt-spray test of 9.2.2. is carried out 

c) Neither blister, peeling off, nor rust shall develop on the coated surface when the salt-spray test of

9.2.2 is carried out.

Dimension, Mass, Effective Length of Threaded Part and Tolerances on 
Outside Diameter and Mass

a) The dimension, mass effective length of threaded part and tolerances on outisde diameter and mass of 

a conduit tube shall be as given in Tabel 1, 2 and 3

b) In general, the length shall be 3660mm and the tolerance shall be

±

5mm, However, the length may 

be changed according to the agreement between the parties concerned with acceptance.

KS C 8401& 

JIS C 8305-
Zinc Coated

Scope

This Korea Industrial Standard specifies rigid steel conduits, (here-after referred to as the “conduit tubes”)
used for protecting electric wires in electrical wiring work.

E

Rigid Conduits

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

Electrical Conduit / Cable Trays

E10 _ E11

Note

(

1

) The mass given in Tables 1 and 2 indicates the mass not including that of threaded part.

(

2

) Tolerance on mass per one bundle of conduit tubes (within 50 kg) shall be-7%. No tolerance on plus side is specified. In the

calculation of tolerance on mass, the difference of actual mass and  calculated  mass is divided by the calculated mass and
expressed in percentage.  The value of mass is calculated from the following formula, by taking the mass of a c

steel as 

7.85 g, and rounded off to three significant figures in accordance with KS A 0021.

C 19

C 25

C 31

C 39

C 51

C 63

C 75

19.1

25.4

31.8

38.1

50.8

63.5

76.2

±

0.2

±

0.2

±

0.2

±

0.2

±

0.2

±

0.35

±

0.35

1.6

1.6

1.6

1.6

1.6

2.0

2.0

0.690

0.939

1.19

1.44

1.94

3.03

3.66

14

17

19

21

24

27

30

12

15

17

19

22

25

28

Designation

Outside

Diameter (mm)

Tolerance 

on Outside

Diameter (mm)

Thickness

(mm) 

Mass

(

1

)(

2

)

(Kg/m)

Effective length of

threaded part (mm)

Max.

Min.

E 19

E 25

E 31

E 39

E 51

E 63

E 75

19.1

25.4

31.8

38.1

50.8

63.5

76.2

±

0.15

±

0.15

±

0.15

±

0.15

±

0.15

±

0.25

±

0.25

1.2

1.2

1.4

1.4

1.4

1.6

1.6

0.530

0.716

1.05

1.27

1.71

2.44

3.30

Designation

Outside

Diameter (mm)

Tolerance 

on Outside

Diameter (mm)

Thickness

(mm) 

Mass

(

1

)(

2

)

(Kg/m)

G 16

G 22

G 28

G 36

G 42

G 54

G 70

G 82

G 92

G 104

21.0

26.5

33.3

41.9

47.8

59.6

75.2

87.9

100.7

113.4

±

0.3

±

0.3

±

0.3

±

0.3

±

0.3

±

0.3

±

0.3

±

0.3

±

0.4

±

0.4

2.3

2.3

2.5

2.5

2.5

2.8

2.8

2.8

3.5

3.5

1.06

1.37

1.90

2.43

2.79

3.92

5.00

5.88

8.39

9.48

19

22

25

28

28

32

36

40

42

45

16

19

22

25

25

28

32

36

36

39 

Designation

Outside

Diameter (mm)

Tolerance 

on outside

Diameter (mm)

Thickness

(mm) 

Mass

(

1

)(

2

)

(Kg/m)

Effective length of

threaded part (mm)

Max.

Min.

Table 1 Dimension, Mass, Effective Length of Threaded Part and Tolerances on Outside Diameter and
Mass of Thick Rigid Steel Conduit Tubes

Table 2 Dimension, Mass and Tolerances on Outside Diameter and Mass of Threaded Rigid Steel
Conduit Tubes

Table 3 Dimension, Mass and Tolerances on Outside Diameter and Mass of Threadless Rigid Steel 
Conduit Tubes 

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

1/2

”16 GRC

3/4

”-21GRC

1”-27GRC

1-1/4”-35GRC

1-1/2”-41GRC

2”-53GRC

2-1/2”-63GRC

3”-78GRC

3-1/2”-91GRC

4”-103GRC

5”-129GRC

6”-155GRC

16.1

21.2

27.0

35.4

41.2

52.9

63.2

78.5

90.7

102.9

128.9

154.8

21.3

26.7

33.4

42.2

48.3

60.3

73.0

88.9

101.6

114.3

141.3

168.3

2.64

2.72

3.20

3.38

3.51

3.71

4.90

5.21

5.46

2.72

6.22

6.76

3.03

3.03

3.02

3.02

3.02

3.02

3.01

3.01

3.0

3.0

3.0

3.0

35.83

47.63

69.40

91.17

112.95

150.60

239.05

309.63

376.94

441.04

595.85

791.67

Designation

Inside

Diameter (mm)

Outside

Diameter (mm)

Thickness (mm) 

Length without 

coupling meters

Minimum weight of ten unit

lengths with couplings

Attached (kg)

ANSI C 80.1 

Galvanized Rigid Conduit (GRC)

ANSI C 80.

1- Zinc Coated

Scope

This American National Standard for rigid steel conduit is furnished in nominal 10-ft.(3.05m) length,
threaded on each end with one coupling attached. It is protected on the exterior surface with a metallic
zinc coating and on the interior surface with a zinc, enamel, or other equivalent corrosion-resistant
coating.

KS C 8431 & JIS C 8430 

PVC Conduit (PVC)

KS C 8431 &

JIS C 8430-
Class VE

Specified as electrical conduit pipe in Korean Industrial Standards (KS C 8431), equal to JIS 8430. 
Can be installed in the same manner as conventional metal or steel pipes. High impact pipe 
and a complete line of accessories are available. Can be embedded in concrete.

Note

Applicable tolerances : 

Length : 

±

1/4inch (6.35mm) (without coupling)

Outside Diameter : For trade sizes 

½“

(16GRC) through 2

(53GRC) : 

±

0.015inch (

±

0.38mm) / For trade sizes 2-

½

(83GRC)  

through4

(103GRC) : 

±

0.025inch (

±

0.64mm) / For trade sizes 5

(129GRC) through 6

(155GRC) : 

±

1%

Note

1. Nominal size *100 mm complies  with  specificationpermissible in Korea telecommunication Association.

2. Standard length : 4M  

Dimension, Mass, Dimensions and Weights of Rigid Steel Conduit

14

16

22

28

36

42

54

70

82

100

*100

18

22

26

34

42

48

60

76

89

114

111

2.0

2.0

2.0

3.0

3.5

4.0

4.5

4.5

5.9

6.5

5.5

±

0.20

±

0.20

±

0.20

±

0.30

±

0.40

±

0.40

±

0.40

±

0.40

±

0.40

±

0.60

±

0.50

14

18

22

28

35

40

51

67

78

101

100

144

180

216

418

605

791

1,122

1,445

2,202

3,138

2,650

Designation

Outside

Diameter (mm)

Wall

Thickness (mm)

Tolerance of 

wall thickness (mm)

Approximate

inside Diameter (mm)

Calculated 

weight(g/m)

Dimension, Mass, Dimensions and Weights of Class VE PVC & HI-PVC pipe 

Zinc Coating 

Enamel or Equivalent Coating 

The coating on the outside surface is equivalent to a minimum thickness of 0.0008 inch (0.02mm).

This have a smooth continuous surface. An occasional variation due to uneven flow of coating shall 
be acceptable. The coating shall not soften at a temperature of 120

(49

)

E

Rigid Conduits

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

Specific Gravity

Tensile Strength at 15

Elongation at Ultimate

Modulus of Elasticity

Impact Strength

Co-efficient of Linear Expansion

-

Kg/

(psi)

%

Kg/

(psi)

Kg/-cm/

(lb/-ft/inch

²

)

-1

1.35~1.43

470~540(6,700~7,000)

50~150

2.0~2.5x10

4

(2.8~3.6x10

5

)

15~25 (2.7~4.6)

6~8 x10

5

Items

Unit

Characteristic Value

KS C 8431 & JIS C 8430 

HI-PVC Conduit (HI-PVC)

KS C 8431 & 

JIS C 8430

SAMWHA HI PVE pipe which is specially integrated with mechanical strength, sufficient elasticity 
and high impact strength is made to be safe and more effective for all kinds of installation. 
SAMWHA HI PVE pipe is 3~5 times stronger in impact strength than normal PVC pipe.

Properties of  SAMWHA HI-PVC pipe 

Features

Excellent high impact strength.

Non-corrosion and low flow loss.

Easy handling and installation. 

Low cost.

Applications

Cold area installation. 

Ground installation requiring high impact strength. 

All kinds of services in buildings and apartments, especially conduit line of taller building.

Dimensions

ELP Corrugated Hard Poly-ethlyrene Pipe

KS C 8455

Specified as electrical conduit pipe in Korean Industrial Standards (KS C 8455).
High impact pipe and a complete line of accessories are available. 
Can be embedded in concrete.

30

40

50

65

80

100

125

150

175

200

40.0

±

2.0

53.5

±

2.0

64.5

±

2.5

84.5

±

2.5

105

±

3.0

130

±

4.0

160

±

4.0

188

±

4.0

230

±

4.0

260

±

4.0

30.0

±

2.0

40.0

±

2.0

50.0

±

2.5

65.0

±

2.5

80.0

±

3.0

100.0

±

4.0

125.0

±

4.0

150.0

±

4.0

175.0

±

4.0

200.0

±

4.0

10.0

±

0.5

13.0

±

0.8

17.0

±

1.0

21.0

±

1.0

25.0

±

1.0

30.0

±

1.0

38.0

±

1.0

45.0

±

1.5

55.0

±

1.5

60.0

±

1.5

100.0

100.0

100.0

100.0

100.0

100.0

50.0

50.0

30.0

30.0

Designation

Approximate

Outside

Diameter(mm)

Approximate

Inside

Diameter(mm)

Pitch

(mm) 

Unit 

Length(M) 

Electrical Conduit / Cable Trays

E12 _ E13

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

0.840

±

0.004

1.050

±

0.004

1.315

±

0.005

1.660

±

0.005

1.900

±

0.006

2.375

±

0.006

2.875

±

0.007

3.500

±

0.008

4.000

±

0.008

4.500

±

0.009

5.563

±

0.010

6.625

±

0.011

0.048

1.060

1.325

1.672

1.912

2.387

2.890

3.515

4.050

4.550

5.613

6.675

0.832

1.040

1.305

1.648

1.888

2.363

2.860

3.485

3.950

4.450

5.513

6.575

0.855

1.070

1.340

1.685

1.930

2.410

2.910

3.540

4.045

4.550

5.618

6.690

0.825

1.030

1.290

1.635

1.870

2.340

2.840

3.460

3.955

4.450

5.508

6.560

0.080

0.080

0.080

0.090

0.100

0.120

0.130

0.145

0.165

0.170

-

-

0.060

0.060

0.060

0.070

0.080

0.080

0.100

0.125

0.145

0.150

-

-

0.129

0.133

0.153

0.160

0.165

0.174

0.227

0.242

0.253

0.265

0.289

0.314

0.109

0.113

0.133

0.140

0.145

0.154

0.203

0.216

0.356

0.237

0.258

0.280

-

-

-

-

0.224

0.244

0.309

0.336

0.356

0.377

0.420

0.484

-

-

-

-

0.200

0.218

0.276

0.300

0.318

0.337

0.375

0.432

-

-

-

-

1.71

2.87

4.12

6.43

8.65

11.2

17.8

25.8

1/2

3/4

1

1 1/4

1 1/2 

2

2 1/2 

3

3 1/2 

4

5

6

NOMINAL

SIZE

(INCHE)

OUTSIDE DIAMETERS, INCHES

WALL THICKNESS. INCHES

AVERAGE

OUT OF ROUNDNESS

PVC

PE

EPT PVC

EPC.40.PVC

AND EPT PVC

EPC.80.PVC

MINIMUM CROSS 

SECTIONAL AREA, SQUARE

INCHES OF EPC.80.PVC

MAX

MIN

MAX

MIN

MAX

MIN

MAX

MIN

MAX

MIN

0.840

±

0.004

1.050

±

0.004

1.315

±

0.005

1.660

±

0.005

1.900

±

0.006

2.375

±

0.006

2.875

±

0.007

3.500

±

0.008

4.000

±

0.008

4.500

±

0.009

5.563

±

0.010

6.625

±

0.011

0.048

1.060

1.325

1.672

1.912

2.387

2.890

3.515

4.050

4.550

5.613

6.675

0.832

1.040

1.305

1.648

1.888

2.363

2.860

3.485

3.950

4.450

5.513

6.575

0.855

1.070

1.340

1.685

1.930

2.410

2.910

3.540

4.045

4.550

5.618

6.690

0.825

1.030

1.290

1.635

1.870

2.340

2.840

3.460

3.955

4.450

5.508

6.560

0.080

0.080

0.080

0.090

0.100

0.120

0.130

0.145

0.165

0.170

-

-

0.060

0.060

0.060

0.070

0.080

0.080

0.100

0.125

0.145

0.150

-

-

0.129

0.133

0.153

0.160

0.165

0.174

0.227

0.242

0.253

0.265

0.289

0.314

0.109

0.113

0.133

0.140

0.145

0.154

0.203

0.216

0.356

0.237

0.258

0.280

-

-

-

-

0.224

0.244

0.309

0.336

0.356

0.377

0.420

0.484

1/2

3/4

1

1 1/4

1 1/2 

2

2 1/2 

3

3 1/2 

4

5

6

NOMINAL

SIZE

(INCHE)

Outside Diameters

Minimum Wall Thickness

Plus or Minus Tolerance (inch)

Type EB 

Type DB 

Minimum

Inside Diameter

Average

For Average Diameter  Out-of-roundness

ABS

PVC

PVC

ABS

Specified as electrical conduit pipe in NEMA TC-2. Can be installed in the same manner as 
conventional metal or steel pipes. High impact pipe and a complete line of accessories are available. 
Can be embedded in concrete.

Dimensions (Inch)

NEMA TC-6

Specified as electrical conduit pipe in NEMA TC-6. Can be installed in the same manner as 
conventional metal or steel pipes. High impact pipe and a complete line of accessories are available. 
Can be embedded in concrete.

Dimensions (Inch)

NEMA TC-2 & NEMA TC-6 

PVC Conduit (PVC)

NEMA TC-2

E

Rigid Conduits

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

KS C 8422

UL 360

Flexible & Pliable Metallic Conduit (FMC & LFMC)

SAMWHAFLEX

®

SUNFLEX

®

PLICA

®

Scope

This Korea Industrial Standard specifies Flexible Metallic conduits, (here-after referred to as 
the “FMC") used for protecting electric wires in electrical wiring work.

Remarks The following Standards are cited in this Standard

KS C 2329 Bulkernized fiber plate.

KS D 0201 Testing method for melting zinc plated.

KS D 3506 Melting zinc plated steel plate and bar.

KS D 3512 Cold rolled steel plate and bar.

KS D 6701 Aluminum plate and bar of aluminum and alloyed.

KS D 9502 Testing method for the spraying of salt water.

KS M 3156 Soft poly salted vinyl compound.

First class flexible metal conduits(Here in after called as class flexible conduits.)

First class vinyl coated flexible metal conduits.

(Here in after called as first class vinyl coated flexible conduits).

Second class flexible metal conduits.(Here in after called as second class flexible conduits).

Second class vinyl coated flexible metal conduits.

(Here in after called as second class vinyl coated flexible conduit).

Type 

The type of flexible conduits consist of the shall be 4 types as belows.

Performance 

Small lines or cracks and any clearance not be occurred on the any parts of specimen. 
(Test method  8.6)

Bending Performance 

a)Not reached at final point of it. (Test method  8.2(a))
b)Shall not occurred the steel rust or swelling up. (Test method  8.2(b),(c))

Corrosion-resistance 

a)Below 0.02Ω before testing of the described in the item 8.6.
b)Below 0.03 Ω after testing of the described in the item 8.6.

Electric Resistance  

Any cracks on the any parts of specimen not be occurred. (Test method  8.3)

Tension  

Outside diameter of specimen not be increased or reduced by over 30% compared with the diameter 
of previous compression. (Test method  8.4)

Compression 

Electrical Conduit / Cable Trays

E14 _ E15

Flexible & Pliable Metal Conduits

Electrical Conduit / Cable Trays

Electrical Condui

t/

Cable Trays

E

Second class

First class 
Standard  M type

First class
Interlock I type

catalog_eng-html.html
background image

Flexible & Pliable Metallic Conduit (FMC & LFMC)

KS C 8422

UL 360

SAMWHAFLEX

®

SUNFLEX

®

PLICA

®

Structure

Inside surface of the flexible conduits are smooth throughout along the whole length and harmful defects

which damage to the outer sheath of cables shall not be allowed.

Inside surface of flexible conduits. 

First Class Flexible Conduit

Standard Type =

>

M type

Interlock  Type =

>

I type

Second Class Pliable Conduit

1. Metal winding parts – Zinc galvanized thin plate
2. Metal winding parts – Steel thin plate
3. Non-metal winding parts – Insulating paper

Second class pliable conduit have three layer : 

Materials

- First class metal flexible conduit be made in compliance with the KS D 3506, KS D 3512.

- Second class metal flexible conduit be made in compliance with the KS D 3506, KS D 3512, KS D 0701 

and KS C 2329 and also synthetic resin or waterproof paper.

- Vinyl coated first and second class metal flexible conduit be made in compliance with above mentioned 

item a, b and first class or vinyl compound, Which the mechanical strength is equal or over compared 
with the first class product stipulated in KS M 3156.

10 (1/4”)
12 (3/8”)
16 (1/2”)
22 (3/4”)

28 (1”)

36 (1-1/4”)

42 (1-1/2”)

54 (2”)

70 (2-1/2”)

82 (3”)

104 (4”)

-

686(70)

-

10 (1/2”)
12 (1/2”)
15 (1/2”)
17 (1/2”)
24 (3/4”)

30 (1”)

38 (1-1/4”)
50 (1-1/2”)

63 (2”)

76 (2-1/2”)

83 (3”)

101 (4”)

981(100)

1079(110)
1226(125)
1324(135)
1667(170)

-

CAT. NO. OF FIRST CLASS

TENSION LOAD MAX   N(KG.F)

CAT. NO. OF SECOND CLASS

TENSION LOAD MAX   N(KG.F)

Tension Stretching  

10 (1/2”)
12 (1/2”)
15 (1/2”)
17 (1/2”)
24 (3/4”)

30 (1”)

38 (1-1/4”)
50 (1-1/2”)

63 (2”)

76 (2-1/2”)

83 (3”)

101 (4”)

785(80)
932(95)

1128(115)
1255(128)
1667(170)

1961(200)

CAT. NO. OF SECOND CLASS

COMPRESSION LOAD MAX  N(KG.F)

Compression 

10 (1/4”)
12 (3/8”)
16 (1/2”)
22 (3/4”)

28 (1”)

36 (1-1/4”)
42 (1-1/2”)

54 (2”)

70 (2-1/2”)

82 (3”)

104 (4”)

-

100
102
165
216
330
406
457
565
749
889

1016
1219

10 (1/2”)
12 (1/2”)
15 (1/2”)
17 (1/2”)
24 (3/4”)

30 (1”)

38 (1-1/4”)
50 (1-1/2”)

63 (2”)

76 (2-1/2”)

83 (3”)

101 (4”)

35
42
53
60
84

105
133
175
220
266
290
350

CAT. NO. OF

FIRST CLASS

BEND DIA. 

MAX   (MM)

CAT. NO. OF

SECOND CLASS

BEND DIA. 

MAX   (MM)

Bending 

E

Flexible & Pliable Metal Conduits

Electrical Conduit / Cable Trays

882(90)

1334(136)

1961(200)

catalog_eng-html.html
background image

NORMAL

STEEL

SUS

STEEL

SUS

STEEL

SUS

STEEL

SUS

STEEL

SUS

STEEL

SUS

STEEL

STEEL

STEEL KPS

KUS

SIB

SMB

KIB

KMB

SIO

SMO

KIO

KMO

SIH

SMH

KIH

KMH

SIC

SMC

KIC

KMC

SIV

SMV

KIV

KWV

SIS

SMS

SW

GW

KIS

KMS

SI

SM

SF

GF

KI

KM

SUS

WATER PROOF

FLAMMABILITY

COLD
RESISTANT

HEAT
RESISTANT

OIL
RESISTANT

BRAID

UL Certi.

MACHINE

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

CAT. NO. OF FIRST CLASS

#10

(1/4”)

#12

(3/8”)

#16

(1/2”)

#32

(3/4”)

#28

(1.”)

#36

(1-1/4”)

#42

(1-1/2”)

#54

(2”)

#70

(2-1/2”)

#82

(3”)

#104

(4”)

#130

(5”)

Flexible Metal Conduit Selection Table

NORMAL

LIQUID TIGHT

COLD RESISTANT

HEAT RESISTANT

STEEL

SUS

STEEL

SUS

STEEL

STEEL PVH

PE

PVS

PV

PS

PZ

CAT. NO. OF FIRST CLASS

#10

#12

#15

#17

(1/2”)

#24

(3/4”)

#30

(1”)

#38

(1-1/4”)

#50

(1-1/2”)

#63

(2”)

#76

(2-1/2”)

#83

(3”)

#101

(4”)

Pliable Metal Conduit Selection Table

Electrical Conduit / Cable Trays

E16 _ E17

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

First Class SAMWHAFLEX

® 

Flexible Metal Conduits

First Class Normal Flexible Metal Conduits(FMC)

KS C 8422

SAMWHAFLEX

®

Applications

The SAMWHA SAMWHAFLEX

®

First Class Flexible Conduits are used for Non-hazardous areas with 

KFNG Series Box connector.

Features

Smooth inside for easier wire pulling, no hazardous sharp edges or burrs,
will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of conductors.

Materials

Melting Zinc Plated Steel Plate

Stainless Steel Plate

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

13.2

15.6

19.1

24.2

31.1

39.7

44.7

56.0

69.0

85.4

109.2

134.9

6

7

10

12

10

16

11

14

11

13

14

-

8

10

12

17

14

22

16

20

18

23

17

-

5

6

7

10

9

12

10

12

9

10

11

-

6

9

10

15

11

17

13

19

15

17

14

-

50

50

50

50

30

30

20

20

10

10

6

6

-

-

16

22

28

36

42

54

70

82

104

-

-

-

19

25

31

39

51

63

75

-

-

-

#10 (1/4”)

#12 (3/8”)

#16 (1/2”)

#22 (3/4”)

#28 (1”)

#36 (1-1/4”)

#42 (1-1/2”)

#54 (2”)

#70 (2-1/2”)

#82 (3”)

#104 (4”)

#130 (5”)

CAT. NO. OF 

FIRST CLASS

KM&
SM& 
KI& 
SI

MINIMUM OF

INSIDE

DIAMETER (MM)

MAXIMUM OF

OUTSIDE

DIAMETER (MM)

WEIGHTS (KG/ROLL)

COMPATIBLE

CONDUITS

SM

SI

EMT

IMC

KM

KI

LENGTHS 

(M/ROLL)

Dimensions, Weights, Lengths Per 1 roll

10.0

12.3

15.8

20.8

26.4

35.0

40.0

51.3

63.0

78.0

101.6

126.4

E

Flexible & Pliable Metal Conduits

Electrical Conduit / Cable Trays

KM & SM

KI & SI

catalog_eng-html.html
background image

First Class SAMWHAFLEX

® 

Flexible Metal Conduits

First Class Liquid-Tight Flexible Metal Conduits (LFMC)

KS C 8422

SAMWHAFLEX

®

Applications

The SAMWHA SAMWHAFLEX

®

First Class Waterproof Flexible Conduits are used for Non-hazardous areas with

KF Series Box connector.

Features

Suitable for wet locations.

Smooth inside for easier wire pulling, no hazardous sharp edges or burrs, 

will not damage conductors. 

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife. 

90

°

has smooth interior to prevent abrasion of conductors.

Melting Zinc Plated Steel Plate

Stainless Steel Plate 

PVC jacket (-15

~ 60

)

Materials

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

15.0

17.7

21.1

26.4

33.2

42.0

47.7

59.7

72.3

88.7

113.8

140.6

9.5

10.5

15

18

14

22

15

19

16.5

18

24

-

12

17

20

25

21

29

27

33

25

30

27

-

9

10

14

16

13

20

14

18

12

15

16

-

10

16

18

23

18

27

24

32

23

28

25

-

50

50

50

50

30

30

20

20

10

10

6

6

-

-

16

22

28

36

42

54

70

82

104

-

-

-

19

25

31

39

51

63

75

-

-

-

#10 (1/4”)

#12 (3/8”)

#16 (1/2”)

#22 (3/4”)

#28 (1”)

#36 (1-1/4”)

#42 (1-1/2”)

#54 (2”)

#70 (2-1/2”)

#82 (3”)

#104 (4”)

#130 (5”)

CAT. NO. OF 

FIRST CLASS

KMS&
SMS& 
KIS& 
SIS

MINIMUM OF

INSIDE

DIAMETER (MM)

MAXIMUM OF

OUTSIDE

DIAMETER (MM)

WEIGHTS (KG/ROLL)

COMPATIBLE

CONDUITS

SMS

SIS

EMT

IMC

KMS

KIS

LENGTHS 

(M/ROLL)

Dimensions, Weights, Lengths Per 1 roll

10.0

12.3

15.8

20.8

26.4

35.0

40.0

51.3

63.0

78.0

101.6

126.4

Electrical Conduit / Cable Trays

E18 _ E19

Electrical Condui

t/

Cable Trays

E

KMS & SMS

KIS & SIS

catalog_eng-html.html
background image

First Class SAMWHAFLEX

® 

Flexible Metal Conduits

First Class  Heat Resistant Liquid-tight Flexible Metal Conduits (LFMC)

KS C 8422

SAMWHAFLEX

®

Applications

The SAMWHA SAMWHAFLEX

®

First Class Heat

resistant Flexible Conduits are used for Non-
hazardous areas with KF Series Box connector.

First Class SAMWHAFLEX

® 

Flexible Metal Conduits

First Class  Incombustible Liquid-tight Flexible Metal Conduits (LFMC)

KS C 8422

UL 94V-0

SAMWHAFLEX

®

Applications

The SAMWHA SAMWHAFLEX

®

First Class In-combustible Flexible Conduits are used for Non-hazardous areas

with KF Series Box connector.

Features

Suitable for wet locations. 

Smooth inside for easier wire pulling, 
no hazardous sharp edges or burrs, 
will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of 

conductors.

Resists high temperature, water, metal shavings.

Materials

Melting Zinc Plated Steel Plate

Stainless Steel Plate

PVC jacket (-15

~ 105

)

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

Materials

Melting Zinc Plated Steel Plate

Stainless Steel Plate

PVC jacket (-15

~ 60

). UL94V-0

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

15.0

17.7

21.1

26.4

33.2

42.0

47.7

59.7

72.3

88.7

113.8

9.5

10.5

15

18

14

22

15

19

16.5

18

24

12

17

20

25

21

29

27

33

25

30

27

9

10

14

16

13

20

14

18

12

15

16

10

16

18

23

18

27

24

32

23

28

25

50

50

50

50

30

30

20

20

10

10

6

-

-

16

22

28

36

42

54

70

82

104

-

-

19

25

31

39

51

63

75

-

-

#10 (1/4”)

#12 (3/8”)

#16 (1/2”)

#22 (3/4”)

#28 (1”)        

#36 (1-1/4”)

#42 (1-1/2”)

#54 (2”)

#70 (2-1/2”)

#82 (3”)

#104 (4”)

CAT. NO. OF 

FIRST CLASS

MINIMUM OF

INSIDE

DIAMETER (MM)

MAXIMUM OF

OUTSIDE

DIAMETER (MM)

WEIGHTS (KG/ROLL)

COMPATIBLE

CONDUITS

SMV, H

SIV, H

EMT

IMC

KMV, H

KIV, H

LENGTHS 

(M/ROLL)

Dimensions, Weights, Lengths per 1 roll

Features

Suitable for wet locations. 

Smooth inside for easier wire pulling, no hazardous 

sharp edges or burrs, will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of 

conductors.

Resists flame, water, metal shavings.

10.0

12.3

15.8

20.8

26.4

35.0

40.0

51.3

63.0

78.0

101.6

E

Flexible & Pliable Metal Conduits

Electrical Conduit / Cable Trays

KMV, H & SMV, H

KIV, H & SIV, H

catalog_eng-html.html
background image

Materials

Melting Zinc Plated Steel Plate

Stainless Steel Plate

PVC jacket (-15

~ 60

)

First Class SAMWHAFLEX

® 

Flexible Metal Conduits

First Class Cold Resistant Liquid-tight Flexible Metal Conduits (LFMC)

KS C 8422

SAMWHAFLEX

®

Applications

The SAMWHA SAMWHAFLEX

®

First Class Cold

resistant Flexible Conduits are used for Non-
hazardous areas with KF Series Box connector.

First Class SAMWHAFLEX

® 

Flexible Metal Conduits

First Class  Oil Resistant Liquid-tight Flexible Metal Conduits (LFMC)

KS C 8422

SAMWHAFLEX

®

Applications

The SAMWHA SAMWHAFLEX

®

First Class In-combustible Flexible Conduits are used for Non-hazardous Areas

with KF Series Box connector.

Features

Suitable for wet locations. 

Smooth inside for easier wire pulling, 
no hazardous sharp edges or burrs,  
will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of 

conductors.

Resists cold temperature, water, metal shavings.

Materials

Melting Zinc Plated Steel Plate

Stainless Steel Plate

PVC jacket (-20

~ 60

)

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

15.0

17.7

21.1

26.4

33.2

42.0

47.7

59.7

72.3

88.7

113.8

9.5

10.5

15

18

14

22

15

19

16.5

18

24

12

17

20

25

21

29

27

33

25

30

27

9

10

14

16

13

20

14

18

12

15

16

10

16

18

23

18

27

24

32

23

28

25

50

50

50

50

30

30

20

20

10

10

6

-

-

16

22

28

36

42

54

70

82

104

-

-

19

25

31

39

51

63

75

-

-

#10 (1/4”)

#12 (3/8”)

#16 (1/2”)

#22 (3/4”)

#28 (1”)        

#36 (1-1/4”)

#42 (1-1/2”)

#54 (2”)

#70 (2-1/2”)

#82 (3”)

#104 (4”)

CAT. NO. OF 

FIRST CLASS

MINIMUM OF

INSIDE

DIAMETER (MM)

MAXIMUM OF

OUTSIDE

DIAMETER (MM)

WEIGHTS (KG/ROLL)

COMPATIBLE

CONDUITS

SMC, O

SIC, O

EMT

IMC

KMC, O

KIC, O

LENGTHS 

(M/ROLL)

Dimensions, Weights, Lengths per 1 roll

Features

Suitable for Wet locations. 

Smooth inside for easier wire pulling, 
no hazardous sharp edges or burrs, 
will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of 

conductors.

Resists oil, water, metal shavings.

10.0

12.3

15.8

20.8

26.4

35.0

40.0

51.3

63.0

78.0

101.6

Electrical Conduit / Cable Trays

E20 _ E21

Electrical Condui

t/

Cable Trays

E

KMC, O & SMC, O

KIC, O & SIC, O

catalog_eng-html.html
background image

First Class SAMWHAFLEX

® 

Flexible Metal Conduits

First Class Braid Flexible Metal Conduits (FMC)

KS C 8422

SAMWHAFLEX

®

Applications

The SAMWHA SAMWHAFLEX

®

First Class Flexible Conduits are used for Non-hazardous

areas with KFNG Series Box connector.

Features

Smooth inside for easier wire pulling, no hazardous sharp edges or burrs, 

will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of conductors.

Prevent conduit pullout due to stress, tension, strain, vibration, or movement.

Materials

Melting Zinc Plated Steel Plate

Stainless Steel Plate

Stainless Steel Wire : Braid

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

16.9

20.4

25.4

32.3

41.0

45.9

57.2

15

17

22

21

27

20

25

17

19

25

23

30

24

29

14

16

21

20

26

19

24

16

17

24

21

28

22

28

50

50

50

50

30

20

20

-

16

22

28

36

42

54

-

19

25

31

39

51

63

#12 (3//88

)

#16 (1/2

)

#22 (3/4

)

#28 (1

)

#36 (1-1/4

)

#42 (1-1/2

)

#54 (2

)

CAT. NO. OF 

FIRST CLASS

MINIMUM OF

INSIDE

DIAMETER (MM)

MAXIMUM OF

OUTSIDE

DIAMETER (MM)

WEIGHTS (KG/ROLL)

COMPATIBLE

CONDUITS

SMB

SIB

EMT

IMC

KMB

KIB

LENGTHS 

(M/ROLL)

Dimensions, Weights, Lengths Per 1 roll

12.3

15.8

20.8

26.4

35.0

40.0

51.3

E

Flexible & Pliable Metal Conduits

Electrical Conduit / Cable Trays

KMB & SMB & KIB & SIB

catalog_eng-html.html
background image

First Class SAMWHAFLEX

® 

Flexible Metal Conduits

First Class UL Listed -special KUS Series 
Liquid-tight Flexible Metal Conduits (LFMC)

UL 360 & KS C 8422

KEPIC-EN Certificate

SAMWHAFLEX

®

Applications

The SAMWHA SAMWHAFLEX

®

First Class UL Listed Liquid-tight Flexible Conduits are used for

Non-hazardous areas with KFXT Series Box connector.

Features

Suitable for wet locations.

Smooth inside for easier wire pulling, no hazardous sharp edges or burrs, 

will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of conductors

#12 (3/8

)~#36 (1-1/4

) of KUS have a structure  of minimizing the electric resistance of

flexible metal conduits and grounding of short-circuit current by inside core of copper wire.

#42 (1-1/2

)~#104 (4

) of KUS need separate grounding wires according to article 351 of NEC.

Melting Zinc Plated Steel Plate

PVC jacket (-15

~ 60

Copper wire

Materials

Compliances / Approvals

UL 360

KEPIC-EN END 1100, END 2000, END 3830

Certificate

UL 360 Certi. NO. : 011702-E201391

KEPIC-EN Certi. No. : EN-335

17.70

21.10

26.40

33.20

42.00

47.70

59.70

72.50

88.40

113.80

8

9.8

16

20

24

27

33

25

30

27

20

20

20

20

20

20

20

10

10

6

50

80

100

140

180

180

270

350

400

500

100

160

200

280

360

360

540

700

800

1,000

-

19

25

31

39

51

63

75

-

-

-

1/2”

3/4”

1”

1-1/4”

1-1/2”

2”

2-1/2”

3”

4”

-

16

22

28

36

42

54

70

82

104

#12 (3/8”)

#16 (1/2”)

#22 (3/4”)

#28 (1”)

#36 (1-1/4”)

#42 (1-1/2”)

#54 (2”)

#70 (2-1/2”)

#82 (3”)

#104 (4”)

CAT. NO. OF 

FIRST CLASS

MINIMUM OF

INSIDE

DIAMETER (MM)

MAXIMUM OF

OUTSIDE

DIAMETER (MM)

MINIMUM OF INNER

CURVE RADIUS (MM)

COMPATIBLE CONDUITS

STATIC

KINETIC

IMC

EMT

GRC

WEIGHTS

(KG/ROLL)

LENGTHS

(M/ROLL)

Dimensions, Weights, Lengths Per 1 roll, Curve Radius

12.30

15.80

20.85

26.45

35.05

40.00

51.30

63.00

78.00

101.60

Electrical Conduit / Cable Trays

E22 _ E23

Electrical Condui

t/

Cable Trays

E

KUS

catalog_eng-html.html
background image

First Class SAMWHAFLEX

® 

Flexible Metal Conduits

First Class Machine Tool-special KPS Series 
Liquid-tight Flexible Metal Conduits (LFMC)

KS C 8422

SAMWHAFLEX

®

Applications

The SAMWHA SAMWHAFLEX

®

First Class Machine tool Liquid-tight Flexible Conduits are used for 

Non-hazardous areas with KF Series Box connector.

Features

Suitable for wet locations.

Smooth inside for easier wire pulling, no hazardous sharp edges or burrs,

will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of conductors.

Superior in flexibility with Polypropylene string inserted structure and mitigating cracks at a 

minimum curvature limit point.

Suitable for machine tool wirings with proper mechanical strength and excellent flexibility.

Melting Zinc Plated Steel Plate

PVC jacket (-15

~ 60

PVC jacket (-20

~ 70

)

Materials

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

21.1

26.4

33.2

42.0

47.7

59.7

16

19

15

23

16

20

50

50

30

30

20

20

19

25

31

39

51

63

16

22

28

36

42

54

#16 (1/2”)

#22 (3/4”)

#28 (1”)

#36 (1-1/4”)

#42 (1-1/2”)

#52 (2”)

CAT. NO. OF 

FIRST CLASS

LENGTHS 

(M/ROLL)

COMPATIBLE CONDUITS

EMT

IMC

MINIMUM OF INSIDE

DIAMETER (MM)

MAXIMUM OF

OUTSIDE 

DIAMETER (MM)

WEIGHTS

(KG/ROLL)

Dimensions, Weights, Lengths Per 1 roll

15.8

20.8

26.4

35.0

40.0

51.3

E

Flexible & Pliable Metal Conduits

Electrical Conduit / Cable Trays

KPS

catalog_eng-html.html
background image

First Class SUNFLEX

® 

Flexible Metal Conduits

First Class Normal Flexible Metal Conduits (FMC)

KS C 8422

SUNFLEX

®

Applications

The SAMWHA SAMWHAFLEX

®

First Class Flexible Conduits are used for Non-hazardous areas with 

KFNG Series Box connector.

Features

Smooth inside for easier wire pulling, no hazardous sharp edges or burrs, will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of conductors.

Materials

Melting Zinc Plated Steel Plate

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

13.2

15.6

19.1

24.2

31.1

39.7

44.7

56.0

69.0

85.4

109.2

134.9

6

7

10

12

10

16

11

14

11

13

14

-

8

10

12

17

14

22

16

20

18

23

17

-

50

50

50

50

30

30

20

20

10

10

6

6

-

-

16

22

28

36

42

54

70

82

104

-

-

-

19

25

31

39

51

63

75

-

-

-

#10 (1/4”)

#12 (3/8”)

#16 (1/2”)

#22 (3/4”)

#28 (1”)

#36 (1-1/4”)

#42 (1-1/2”)

#54 (2”)

#70 (2-1/2”)

#82 (3”)

#104 (4”)

#130 (5”)

CAT. NO. OF 

FIRST CLASS

GF&SF

MINIMUM OF INSIDE

DIAMETER (MM)

MAXIMUM OF OUTSIDE

DIAMETER (MM)

WEIGHTS (KG/ROLL)

COMPATIBLE

CONDUITS

GF

SF

EMT

IMC

LENGTHS 

(M/ROLL)

Dimensions, Weights, Lengths Per 1 roll

10.0

12.3

15.8

20.8

26.4

35.0

40.0

51.3

63.0

78.0

101.6

126.4

Electrical Conduit / Cable Trays

E24 _ E25

Electrical Condui

t/

Cable Trays

E

GF (General type)

SF (Special type)

catalog_eng-html.html
background image

First Class SUNFLEX

® 

Flexible Metal Conduits

First Class Liquid-tight Flexible Metal Conduits (LFMC)

KS C 8422

SUNFLEX

®

Applications

The SAMWHA SAMWHAFLEX

®

First Class Wa-terproof Flexible Conduits are used for Non-hazardous Areas

with KF Series Box Connector.

Features

Suitable for wet locations.

Smooth inside for easier wire pulling, no hazardous sharp edges or burrs, will not damage conductors. 

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife. 

90

°

has smooth interior to prevent abrasion of conductors.

Melting Zinc Plated Steel Plate

PVC jacket (-15

~ 60

)

Materials

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

15.0

17.7

21.1

26.4

33.2

42.0

47.7

59.7

72.3

88.7

113.8

140.6

9.5

10.5

15

18

14

22

15

19

16.5

18

24

-

12

17

20

25

21

29

27

33

25

30

27

-

50

50

50

50

30

30

20

20

10

10

6

6

-

-

16

22

28

36

42

54

70

82

104

-

-

-

19

25

31

39

51

63

75

-

-

-

#10 (1/4”)

#12 (3/8”)

#16 (1/2”)

#22 (3/4”)

#28 (1”)

#36 (1-1/4”)

#42 (1-1/2”)

#54 (2”)

#70 (2-1/2”)

#82 (3”)

#104 (4”)

#130 (5”)

CAT. NO. OF 

FIRST CLASS

GW&SW

MINIMUM OF INSIDE

DIAMETER (MM)

MAXIMUM OF OUTSIDE

DIAMETER (MM)

WEIGHTS (KG/ROLL)

COMPATIBLE

CONDUITS

GW

SW

EMT

IMC

LENGTHS 

(M/ROLL)

Dimensions, Weights, Lengths Per 1 roll

10.0

12.3

15.8

20.8

26.4

35.0

40.0

51.3

63.0

78.0

101.6

126.4

E

Flexible & Pliable Metal Conduits

Electrical Conduit / Cable Trays

GW (General type)

SW (Special type)

catalog_eng-html.html
background image

Second Class PLICA

® 

Pliable Metal Conduits

Second Class Normal Pliable Metal Conduits (FMC)

KS C 8422

PLICA

®

Applications

The SAMWHA PLICA

®

Second Class Pliable Metal Conduits are used for Non-hazardous areas with 

WNG Series Box connector.

Features

Smooth inside for easier wire pulling, no hazardous sharp edges or burrs, will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of conductors

Materials

Melting Zinc Plated Steel Plate

Stainless Steel Plate

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

13.3

16.1

19.0

21.5

28.8

34.9

42.9

54.9

69.1

82.9

88.1

107.3

10

14

16

22

33

19

25

24

17

20

22

16

50

50

50

50

50

25

25

20

10

10

10

6

-

-

-

16

22

28

36

42

54

70

82

104

-

-

19

25

31

39

51

63

75

-

-

-

10 (1/2”)

12 (1/2”)

15 (1/2”)

17 (1/2”)

24 (3/4”)

30 (1”)

38 (1-1/4”)

50 (1-1/2”)

63 (2”)

76 (2-1/2”)

83 (3”)

101 (4”)

CAT. NO. OF

SECOND CLASS

PZ&PS

MINIMUM OF INSIDE

DIAMETER (MM)

MAXIMUM OF OUTSIDE

DIAMETER (MM)

WEIGHTS 

(KG/ROLL)

COMPATIBLE

CONDUITS

EMT

IMC

LENGTHS 

(M/ROLL)

Dimensions, Weights, Lengths Per 1 roll

9.2

11.4

14.1

16.6

23.8

29.3

37.1

49.1

62.6

76.0

81.0

100.2

Electrical Conduit / Cable Trays

E26 _ E27

Electrical Condui

t/

Cable Trays

E

PZ (Zinc plate) 
PS (Stainless steel plate)

catalog_eng-html.html
background image

Second Class PLICA

® 

Pliable Metal Conduits

Second Class Liquid Tight Pliable Metal Conduits (LFMC)

KS C 8422

PLICA

®

Applications

The SAMWHA PLICA

®

Second Class Water-proof Pliable Metal Conduits are used for Non-hazardous areas with 

W Series Box connector.

Features

Suitable for wet locations.

Smooth inside for easier wire pulling, no hazardous sharp edges or burrs, will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of conductors

Materials

Melting Zinc Plated Steel Plate

Stainless Steel Plate

PVC jacket (-15

~ 60

)

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

14.9

17.7

20.6

23.1

30.4

36.5

44.9

56.9

71.5

85.3

90.9

110.1

13

18

22

29

38

25

30

31

22

28

29

24

50

50

50

50

50

25

25

20

10

10

10

6

-

-

-

16

22

28

36

42

54

70

82

104

-

-

-

19

25

31

39

51

63

75

-

-

10 (1/2”)

12 (1/2”)

15 (1/2”)

17 (1/2”)

24 (3/4”)

30 (1”)

38 (1-1/4”)

50 (1-1/2”)

63 (2”)

76 (2-1/2”)

83 (3”)

101 (4”)

CAT. NO. OF

SECOND CLASS

PV&PVS

MINIMUM OF INSIDE

DIAMETER (MM)

MAXIMUM OF OUTSIDE

DIAMETER (MM)

WEIGHTS 

(KG/ROLL)

COMPATIBLE

CONDUITS

EMT

IMC

LENGTHS 

(M/ROLL)

Dimensions, Weights, Lengths Per 1 roll

9.2

11.4

14.1

16.6

23.8

29.3

37.1

49.1

62.6

76.0

81.0

100.2

E

Flexible & Pliable Metal Conduits

Electrical Conduit / Cable Trays

PV (Zinc plate) 
PVS (Stainless steel plate)

catalog_eng-html.html
background image

14.9

17.7

20.6

23.1

30.4

36.5

44.9

56.9

71.5

85.3

90.9

110.1

13

18

22

29

38

25

30

31

22

28

29

24

50

50

50

50

50

25

25

20

10

10

10

6

-

-

-

16

22

28

36

42

54

70

82

104

-

-

-

19

25

31

39

51

63

75

-

-

10 (1/2”)

12 (1/2”)

15 (1/2”)

17 (1/2”)

24 (3/4”)

30 (1”)

38 (1-1/4”)

50 (1-1/2”)

63 (2”)

76 (2-1/2”)

83 (3”)

101 (4”)

CAT. NO. OF

SECOND CLASS

PVH&PE

MINIMUM OF INSIDE

DIAMETER (MM)

MAXIMUM OF OUTSIDE

DIAMETER (MM)

WEIGHTS 

(KG/ROLL)

COMPATIBLE

CONDUITS

EMT

IMC

LENGTHS 

(M/ROLL)

Dimensions, Weights, Lengths Per 1 roll

9.2

11.4

14.1

16.6

23.8

29.3

37.1

49.1

62.6

76.0

81.0

100.2

Second Class PLICA

® 

Pliable Metal Conduits

Second Class  Heat Resistant Liquid-tight Flexible Metal Conduits (LFMC)

KS C 8422

PLICA

®

Applications

The SAMWHA PLICA

®

Second Class Heat resistant Pliable Metal Conduits are used for Non-hazardous areas with

W Series Box connector.

Second Class PLICA

® 

Pliable Metal Conduits

Second Class Cold Resistant Liquid-tight Flexible Metal Conduits (LFMC)

KS C 8422

PLICA

®

Applications

The SAMWHA PLICA

®

Second Class Cold resistant Pliable Metal Conduits are used for Non-hazardous areas

with W Series Box connector.

Features

Suitable for wet locations.

Smooth inside for easier wire pulling, no hazardous sharp edges or burrs, will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of conductors

Resists high temperature, water, metal shavings

Materials

Melting Zinc Plated Steel Plate

PVC jacket (-15

~ 105

)

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

Materials

Melting Zinc Plated Steel Plate

PVC jacket (-20

~ 60

)

Features

Suitable for wet locations.

Smooth inside for easier wire pulling, no hazardous sharp edges or burrs, will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of conductors

Resists cold temperature, water, metal shavings

Compliances / Approvals

KS C 8422 Flexible Metal Conduits

Electrical Conduit / Cable Trays

E28 _ E29

Electrical Condui

t/

Cable Trays

E

PVH (Heat resistant)
PE (Cold resistant)

catalog_eng-html.html
background image

For Communication Flexible Metal Conduits (FMC)

Applications

The SAMWHA First Class Communication type Flexible Conduits are used for Non-hazardous
areas with SI Series Box connector.

Features

Smooth inside for easier wire pulling, no hazardous sharp edges or burrs, will not damage conductors.

Corrosion resistant for touch environmental conditions.

Quick installation, cuts with utility knife.

90

°

has smooth interior to prevent abrasion of conductors

Materials

Stainless Steel 

4.8

5.8

7.5

10.5

12.8

15.3

16.7

19.0

200

200

100

100

50

50

50

50

#3

#4

#5.5

#8

#10

#12

#14

#16

CAT. NO. OF 

FIRST CLASS

CSM

CSI

MINIMUM OF 

INSIDE DIAMETER (MM)

MAXIMUM OF 

OUTSIDE DIAMETER (MM)

LENGTHS 

(M/ROLL)

Dimensions, Lengths

Applications

One Hole Straps are commercial product line for use with Rigid Metal Conduits (RMC) or Intermediate
Metal Conduits (IMC) or Galvanized Rigid Conduits (GRC).

Standard Materials

Body-Stainless steel or Zinc Electro Galvanized Steel

3.3

4.0

5.5

8.0

10.0

12.0

14.0

16.0

Selection Table

OHS One Hole Straps

One Hole Straps For Rigid Metal Conduits

OHST

16 (1/2”)

22 (3/4”)

28 (1”)

36 (1-1/4”)

42 (1-1/2”)

54 (2”)

70 (2-1/2”)

82 (3”)

92 (3-1/2”)

104 (4”)

10.7

13.3

16.6

21.1

24.1

30.1

36.5

44.4

50.8

57.2

6.5

6.5

8.0

9.5

11.0

14.5

14.5

14.5

14.5

14.5

18.1

22.7

31.8

45.4

63.5

90.7

190.5

231.3

317.5

353.8

CAT. NO. 

DIMENSIONS(MM)

RADIUS

HOLE

WEIGHT

(G/EA)

E

Flexible & Rigid Metal Conduits

Electrical Conduit / Cable Trays

CSM (Standard type)

CSI (Interlock type)

catalog_eng-html.html
background image

Applications

Two Hole Straps are commercial product line for use with Rigid Metal Conduits (RMC) or 
Intermediate Metal Conduits (IMC) or Galvanized Rigid Conduits (GRC).

Standard Materials

Body-Stainless Steel or Zinc Electro Galvanized Steel

THS Two Hole Straps 

Two Hole Straps For Rigid Metal Conduits

Applications

One Hole Clamps are commercial product line for use with Rigid Metal Conduits (RMC) or
Intermediate Metal Conduits (IMC) or Galvanized Rigid Conduits (GRC).

Standard Materials

Body-Malleable Iron

OHC One Hole Clamps

One Hole Clamps For Rigid Metal Conduits

Electrical Conduit / Cable Trays

E30 _ E31

Fitting for Rigid Metal Conduits

Electrical Conduit / Cable Trays

Electrical Condui

t/

Cable Trays

E

Selection Table

THST

16 (1/2”)

22 (3/4”)

28 (1”)

36 (1-1/4”)

42 (1-1/2”)

54 (2”)

70 (2-1/2”)

82 (3”)

92 (3-1/2”)

104 (4”)

10.7

13.3

16.6

21.1

24.1

30.1

36.5

44.4

50.8

57.2

4.8

4.8

6.5

6.5

6.5

9.5

9.5

9.5

11.0

11.0

9.1

13.6

18.1

27.2

40.8

54.4

72.6

90.7

131.5

145.1

CAT. NO. 

DIMENSIONS(MM)

RADIUS

HOLE

WEIGHT

(G/EA)

Selection Table

OHC

16 (1/2”)

22 (3/4”)

28 (1”)

36 (1-1/4”)

42 (1-1/2”)

54 (2”)

70 (2-1/2”)

82 (3”)

92 (3-1/2”)

104 (4”)

27.2

36.3

59.0

90.7

136.0

290.3

471.7

544.3

680.4

997.9

CAT. NO. 

WEIGHT

(G/EA)

catalog_eng-html.html
background image

Applications

One Hole Clamp-backs are commercial product line for use with Rigid Metal Conduits (RMC) or
Intermediate Metal Conduits (IMC) or Galvanized Rigid Conduits (GRC).

Standard Materials

Body-Malleable Iron

OHCB One Hole Clamp Back

One Hole Clamp Back / Spacers For Rigid Metal Conduits

Applications

Used to provide mechanical support to conduit and raceway systems.

Standard Materials

Body-Zinc Electro Galvanized Steel

CHG Cable & Conduit Hangers On Wall

Cable And Conduit Hangers On Wall

E

Fitting for Rigid Metal Conduits

Electrical Conduit / Cable Trays

Selection Table

OHCB

16 (1/2”)

22 (3/4”)

28 (1”)

36 (1-1/4”)

42 (1-1/2”)

54 (2”)

70 (2-1/2”)

82 (3”)

92 (3-1/2”)

104 (4”)

36.3

45.3

54.4

95.2

190.5

181.4

222.3

281.2

412.8

500.0

CAT. NO. 

WEIGHT

(G/EA)

Selection Table

CHG

16 (1/2”)

22 (3/4”)

28 (1”)

36 (1-1/4”)

42 (1-1/2”)

54 (2”)

70 (2-1/2”)

82 (3”)

92 (3-1/2”)

104 (4”)

CAT. NO. 

catalog_eng-html.html
background image

Applications

Used to provide mechanical support to conduit and raceway systems.

Standard Materials

Body-Zinc Electro Galvanized Steel

CCL Cable & Conduit Clips 

Cable And Conduit Clips

Applications

Used to provide mechanical support to conduit and raceway systems.

Standard Materials

Body-Zinc Electro Galvanized Steel

CCP Two Piece Conduit Clamps With Channel 

Two Piece Conduit Clamps With Channel

Electrical Conduit / Cable Trays

E32_ E33

Electrical Condui

t/

Cable Trays

E

Selection Table

CCL

16 (1/2”)

22 (3/4”)

28 (1”)

36 (1-1/4”)

42 (1-1/2”)

54 (2”)

CAT. NO. 

Selection Table

CCP

16 (1/2”)

22 (3/4”)

28 (1”)

36 (1-1/4”)

42 (1-1/2”)

54 (2”)

70 (2-1/2”)

82 (3”)

92 (3-1/2”)

104 (4”)

CAT. NO. 

catalog_eng-html.html
background image

Applications

Beam Clamps are commercial product line for use with Cannel

Features

Jaw Openings-17mm

Tapped Holes-M6.0

BCP Beam Clamps 

Beam Clamps / Insulator Supports

Standard Materials

Body-Zinc Electro Galvanized Steel

CUB U-Bolts 

U-Bolts

Standard Materials

Body-Zinc Electro Galvanized Steel

Model - BCP

Model - CUB

Model - SCN

Applications

Continuous channel framing uses a channel fitting with simple nut-and-bolt connection for quick, easy construction. 

Standard Materials

Body-Zinc Hot Dip Galvanized Steel or Zinc Electro Galvanized Steel

SCN Strut Channels 

Strut Channels

E

Fitting for Rigid Metal Conduits

Electrical Conduit / Cable Trays

Selection Table

CUB

16 (1/2”)

22 (3/4”)

28 (1”)

36 (1-1/4”)

42 (1-1/2”)

54 (2”)

70 (2-1/2”)

82 (3”)

92 (3-1/2”)

104 (4”)

61.2

69.3

77.2

80.3

88.4

109.2

122.0

136.0

147.3

165.1

23.9

29.2

35.8

44.7

50.8

63.2

76.0

91.7

104.4

117.1

59.0

63.5

68.0

72.6

81.6

136.0

154.2

172.4

181.4

204.0

CAT. NO. 

DIMENSIONS(MM)

A

C

38.0

38.0

38.0

38.0

38.0

44.5

44.5

44.5

44.5

44.5

B

WEIGHT

(G/EA)

Selection Table

SCN

(Elec. galva.)

(Elec. galva.)

(Hot dip)

(Hot dip)

(Hot dip)

(Hot dip)

39A

42A

42B

42C

42D

84A

39

42

42

42

42

84

1.2

1.6

1.6

2.6

2.6

2.6

1.2

1.2

1.2

3.0

3.0

3.0

CAT. NO. 

DIMENSIONS(MM)

W

T

22

25

25

25

42

42

H

LENGTH (M)

catalog_eng-html.html
background image

SLCC cable tray conduit clamps are used for installation on cable tray side rails with inside flanges 
(requiring inside tray mounting) and outside flanges; SLCCF clamps are for use exclusively on inside flanges.

SLCC Series 

Cable Tray Conduit Clamps

- Provide a means of clamping metal conduit (rigid steel or aluminum, IMC and EMT) to cable tray to 

provide for the exit of power and/or control cables from tray.

- Provide a means to firmly bond exit conduit to cable tray for best grounding continuity. 
- Provide strong mechanical support for exit conduits and cables.
- Can be used indoors or outdoors, wherever cable tray systems are installed.
- Facilitate the safe exit of cables from tray-insure protection of cables from damage.

SLCC/SLCCF cable tray conduit clamps:

Applications

- Quick and easy installation 
– low installed cost. Merely tighten clamp  

nut and/or set screw(s).

- Swivel hook clears conduit. No disassembly 

required for installation.

- No drilling or welding necessary for installation.

- Provides superior ground continuity between 

conduit and cable tray.

- Clamps conduit at any angle with relation to tray 

facilitates wire pulling, minimizes conduit bending.

Features

- Body – Cast Iron / Hook – Steel
- Set screws and clamping nut – Steel
- Hook cap – Vinyl

Standard Materials

Cast Iron – Zinc Hot Dip Galvanized

Steel – Zinc Electro Plate

Vinyl – Natural

Standard Finishes

- Malleable iron body provides great strength.
- Knurled body has no-slip surface for conduit and 

tray – positive grip assured.

- Compact design has low profile – minimum tray 

space required for assembly.

- Design accommodates all popular types of cable tray.
- Accommodates wide range of conduit sizes – 1/2" 

through 4“.

- Outside mounting facilitates inside rail installation. 

(SLCCF)

Selection Table

SLCC

1/2”

3/4”

1”

1-1/4”

1-1/2”

2”

2-1/2”

3”

3-1/2”

4”

SLCCF 16

SLCCF 22

SLCCF 28

SLCCF 36

SLCCF 42

SLCCF 54

SLCCF 70

SLCCF 82

SLCCF 92

SLCCF 104

SLCC 16

SLCC 22

SLCC 28

SLCC 36

SLCC 42

SLCC 54

SLCC 70

SLCC 82

SLCC 92

SLCC 104

OUTSIDE FLANGE

INSIDE FLANGE

CONDUIT SIZE

For use with outside rail tray        

Model Number Logic

Threads Spec.

None : outside flange
F : inside flange

Conduit size

#16(1/2”)~#104(4”)

Example 1) outside flange type conduit size 1” SLCC 28   
Example 2) inside flange type conduit size 2” SLCCF 54

Select 
Constant

0

SLCC

0

SLCCF

For use with inside rail tray

Electrical Conduit / Cable Trays

E34 _ E35

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

Couplings

KS C 8433 for Rigid Non Metal (PVC) Conduits

Dimensions (mm)

53

63

73

83

91

113

129

141

147

195

14

16

22

28

36

42

54

70

82

100

18.40

±

0.20

22.40

±

0.20

26.45

±

0.20

34.55

±

0.25

42.60

±

0.25

48.70

±

0.30

60.80

±

0.30

76.80

±

0.30

89.80

±

0.30

115.00

±

0.30

17.60

±

0.20

21.60

±

0.20

25.55

±

0.20

33.450.25

41.400.25

47.30

±

0.30

59.20

±

0.30

75.20

±

0.30

88.20

±

0.30

112.90

±

0.30

22-0.30

26-0.30

30-0.40

40-0.50

50-0.60

57-0.60

70-0.70

86-0.70

101-0.70

129-0.70

25

30

35

40

44

55

63

69

72

92

1.0

1.0

1.0

1.8

2.2

2.2

2.5

3.0

3.5

4.5

CAT. NO. 

d1

d2

D

I

L

t

Dimensions (mm)

14

16

22

28

36

42

54

70

82

100

14

±

2

18

±

2

22

±

2

28

±

3

35

±

4

40

±

4

51

±

5

67

±

7

77

±

8

101

±

10

1.0

1.0

1.0

1.8

2.2

2.2

2.5

3.0

3.5

4.5

14

±

0.8

18

±

0.8

22

±

0.9

28

±

1.2

35

±

1.5

40

±

1.6

51

±

1.7

67

±

1.7

77.2

±

1.7

101

±

1.8

CAT. NO. 

d4

t

(MIN)

d

105

120

140

185

230

260

325

410

490

620

H

75

85

100

135

170

190

240

300

360

460

R

Dimensions (mm)

20

±

0.3

20

±

0.3

20

±

0.3

26

±

0.5

34

±

0.5

40

±

0.5

51

±

0.6

67

±

1.0

77

±

1.0

100

±

1.2

14

16

22

28

36

42

54

70

82

100

22-0.6

26-0.6

30-0.8

40-1.0

50-1.2

57-1.2

70-1.5

86-1.5

101-1.5

129-1.8

44

±

4

50

±

4

54

±

4

64

±

4

68

±

4

84

±

4

97

±

4

110

±

4

113

±

4

142

±

4

30

30

30

41

50

57

70

86

101

129

2

2

2

2

2

2

2

2

2

2

1.0

1.0

1.0

1.8

2.2

2.2

2.5

3.0

3.5

4.5

CAT. NO. 

D

L

B

a

(MIN)

t

(MIN)

I.1

d3

17

17

17

23

25

31

35

40

44

50

Connectors

KS C 8434 for Rigid Non Metal (PVC) Conduits

Normal Bends

KS C 8441 for Rigid Non Metal (PVC) Conduits

E

Fitting for Rigid Non-
Matel PVC & HI-PVC Conduits

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

ELP Couplings

ELP Bell Mouths

30

40

50

65

80

100

125

150

175

200

47

±

2.0

61

±

2.0

72

±

2.5

91

±

2.5

111

±

3.0

142

±

4.0

174

±

4.0

204

±

4.0

237

±

4.0

267

±

4.0

10.0

±

0.5

13.0

±

0.8

17.0

±

1.0

21.0

±

1.0

25.0

±

1.0

30.0

±

1.0

38.0

±

1.0

45.0

±

1.5

55.0

±

1.5

60.0

±

1.5

70.0

91.0

116.0

147.0

172.0

224.0

275.0

232.0

275.0

275.0

DESIGNATION

*APPROXIMATE

OUTSIDE

DIAMETER (MM) 

PITCH

(MM)

*LENGTH (M)

KS C 8455

ELP Bell Mouth

ELP Bell Mouths

KS C 8455

ELP Couplings 

for ELP with PVC Conduits

Dimensions 

Dimensions (mm)

100

125

150

175

200

115

140

170

200

230

140

175

210

245

280

2.5

3.0

3.5

4.0

4.5

150

165

180

200

230

30

38

45

55

60

300

330

360

400

460

DESIGNATION

INSIDE

DIAMETER

OUTSIDE

DIAMETER

THICKNESS

(MIN)

LENGTH 

PITCH

ELP SIDE

LENGTH 

OF ALL

(MIN)

KS C 8455

Spacers 

for ELP pipe

Dimensions (mm)

30

40

50

65

80

100

125

150

175

200

180

180

135

180

200

225

300

300

300

300

35.0

35.0

35.0

35.0

35.0

35.0

35.0

35.0

35.0

35.0

O48.0

O68.0

O68.0

O108

O143

O168

O200

O235

O265

O265

DESIGNATION

WIDTH & HEIGHT

DEPTH

INSIDE DIAMETER

DIMENSION (M/M)

124

148

172

198

230

300

330

360

400

460

124

148

172

198

230

130

158

180

207

240

3.0

3.5

4.0

4.5

5.0

150

165

180

200

230

DESIGNATION

INSIDE

DIAMETER

OUTSIDE

DIAMETER

THICKNESS

(MIN)

LENGTH 

PVC CONDUITS SIDE

LENGTH 

OF ALL

(MIN)

Electrical Conduit / Cable Trays

E36 _ E37

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

KFNG Series for First Class Flexible Conduit Type

Conduit Fittings for First Class Flexible Metal Conduits (KS C 8422)

KS C 8459

Applications

KFNG Series indoor conduit fittings for use with all type Non liquid-tight Flexible metal conduit, providing
mechanical conduit retention and electrical continuity .

Features

Available in various configurations in various trade sizes.

Lock nut bites into box.

Standard Materials

Bodies & Locknuts–Zinc Die Casting

Compliance / Approvals

KS C 8459 Fittings for flexible metal conduits

KFNG

15.0

15.0

22.0

24.0

37.0

47.0

52.0

58.0

14.0

14.0

26.0

27.0

32.0

34.0

42.0

42.0

30.0

20.0

40.0

60.0

110.0

150.0

210.0

280.0

10 (1/2”)

12 (1/2”)

16 (1/2”)

22 (3/4”)

28 (1”)

36 (1-1/4”)

42 (1-1/2”)

54 (2”)

CAT. NO. 

KFNG

DIMENSIONS (MM)

THREADS

WEIGHT (G/EA)

KFBG

ROTATE RADIUS

PROTRUSION LENGTH 

Selection Table

PF 16

PF 16

PF 16

PF 22

PF 28

PF 36

PF 42

PF 54

E

PLICA

®

BP Series - Non Hazard.  

Bushings (PVC)

CAT. NO. OF 

SECOND CLASS

PZ & PS

10 (1/2

)

12 (1/2

)

15 (1/2

)

17 (1/2

)

24 (3/4

)

30 (1

)

38 (1-1/4

)

50 (1-1/2

)

63 (2

)

76 (2-1/2

)

83 (3

)

101 (4

)

For Second Class

Pliable Normal
Conduits PZ or PS

90

Rated PVC

KS C 8459

Fitting for Flexible & Pliable Metal
Conduits Non-liquid Tight Fittings

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

WNG Series for Second Class Pliable Conduit Type

Conduit Fittings for Second Class Pliable Metal Conduits (KS C 8422)

KS C 8459

Applications

WNG Series indoor conduit fittings for use with all type Non liquid-tight Pliable metal conduit, providing mechanical
conduit retention and electrical continuity .

Features

Available in various configurations in various trade sizes.

Lock nut bites into box.

Compliances / Approvals

KS C 8459 Fittings for flexible metal conduits

CTC 19

CTC 19

CTC 19

CTC 19

CTC 25

CTC 31

CTC 39

CTC 51 

CTC 63

CTC 75

-

-

-

NPT 1/2”

NPT 1/2”

NPT 1/2”

NPT 3/4”

NPT 1

NPT 1-1/4”

NPT 1-1/2”

NPT 2”

NPT 2-1/2”

NPT 3”

NPT 4”

26.0

26.0

26.0

29.0

36.0

43.0

54.0

66.0

82.0

96.0

102.0

126.0

18.0

18.0

18.0

20.0

23.0

23.0

26.0

29.0

37.0

39.0

39.0

44.0

40.0

40.0

40.0

40.0

70.0

90.0

150.0

210.0

320.0

460.0

520.0

920.0

10 (1/2”)

12 (1/2”)

15 (1/2”)

17 (1/2”)

24 (3/4”)

30 (1”)

38 (1-1/4”)

50 (1-1/2”)

63 (2”)

76 (2-1/2”)

83 (3”)

101 (4”)

CAT. NO. 

THREADS

DIMENSIONS (MM)

WNG

WBG

WBC

WBT

ACROSS 

CORNERS 

PROTRUSION

LENGTH 

WEIGHT (G/EA)

Selection Table

PF 16

PF 16

PF 16

PF 16

PF 22

PF 28

PF 36

PF 42

PF 54

PF 70

PF 82

PF 104

Standard Materials

Bodies & Locknuts–Zinc Die Casting

Electrical Conduit / Cable Trays

E38 _ E39

Electrical Condui

t/

Cable Trays

E

WNG

catalog_eng-html.html
background image

KF Series for First Class Flexible Conduit Type 

Liquid-tight Conduit Fittings  for First 

Class Flexible Metal Conduits (KS C 8422) KEPIC-EN Certificate **(Grounding type only)

KS C 8459

UL Listed*

SAMWHA liquid-tight product line offers high-quality, high-performance fittings. Designed to the toughest
standards and integrating the latest technology, not only do you get a reliable and durable product, you also get
one that reduces installation time and cost. Our versatile lines of liquid-tight fittings are designed for a wide
range of applications. 

Applications

Typical applications for liquid-tight conduit and liquid-
tight fittings include the wiring of machine tools,
motors, transformers, food processing equipment,
robotics, air conditioning units, illuminated store front
signs and billboards, etc. The flexible metallic conduit
and fittings protect conductors from mechanical
damage due to vibration and movement, and seal out
cutting oils, coolants, water, dust, etc.

Applications such as these can be found in, but are
not limited to, industries such as:

Machine tool manufacturers

Electric power generating plants

Waste treatment facilities

Paint manufacturing facilities

Automobile manufacturing facilities

Aerospace industries

Breweries

Food processing plants

Dairies

Pulp and paper mills

Petroleum refineries

Chemical and petrochemical plants

Features

Provides protection in wet locations.

Available in various configurations in various 
trade sizes.

Hex surfaces on gland nut and Thermoplastic 
elastomer sealing gasket effectively seals out 
water, oil, dust and dirt.

Lock nut bites into box.

Cupped long grounding ferrule is distortion-free.

Standard Materials

Bodies & Nuts & Locknuts – Zinc Die Casting

Ferrule – Stainless Steel

Gland nut sealing ring – Neoprene or Rubber

Sealing Gasket – Neoprene or Rubber

Compliance / Approvals

KS C 8459 Fittings for flexible metal conduits

*UL 514B Fittings for cable and conduit

**KEPIC-EN END 1100, END 2000, END 3830

Certification

*UL 514B Certi. NO. : 011702-E201392

**KEPIC-EN Certi. No. : EN-335 

Model Number Logic

Threads size

#10~#130

Select
Constant

KF

Outlet type

B : Straight male
U : Straight female
A : Angle male

0

Threads Spec.

G : BSPP Threads
C : CTC Threads
*T : NPT Threads

0

00

Angle Spec.

45 :45

°

angle

90 :90

°

angle

0

Grounding

None:normal 
E :Grounding

0

Example 1) Straight PF threads Male 1/2

KFBG 16

Example 2) 45

°

NPT threads Male 1-1/2

KFAT 42

E

KFBG

KFBC & *KFBT & **-E 

KFUG & KFUC  & 
*KFUT & **-E

KFAG 90° &
*KFAT 90° & **-E

KFAG 45° &
*KFAT 45° & **-E

**Grounding type 
Earth Nuts

Fitting for Flexible & Pliable Metal
Conduits Liquid Tight Fittings

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

CTC 19
CTC 19
CTC 19
CTC 25
CTC 31
CTC 39
CTC 51
CTC 63
CTC 75

-
-
-

-

NPT 1/2”
NPT 1/2”
NPT 3/4”

NPT 1

NPT 1-1/4”
NPT 1-1/2”

NPT 2”

NPT 2-1/2”

NPT 3”
NPT 4”
NPT 5”

29.0
32.0
36.0
41.0
48.0
59.0
68.0
81.0

102.0
121.0
153.0
177.0

35.0
23.0
25.0
27.0
32.0
36.0
41.0
44.0
49.0
52.0
69.0
71.0

44.0
56.0
72.0

104.0
160.0
246.0
350.0
518.0
834.0

1,256.0
2,150.0

-

10 (1/2”)
12 (1/2”)
16 (1/2”)
22 (3/4”)
28 (1”)
36 (1-1/4”)
42 (1-1/2”)
54 (2”)
70 (2-1/2”)
82 (3”)
104 (4”)
130 (5”)

CAT. NO. 

THREADS

DIMENSIONS (MM)

KFBG & 
KFBC &

*KFBT &

**KFBTE

KFBG

KFBC

KFBT

ACROSS 

CORNERS 

PROTRUSION

LENGTH 

WEIGHT 

(G/EA)

Selection Table 1 – Straight Box Male Connector

PF 16
PF 16
PF 16
PF 22
PF 28
PF 36
PF 42
PF 54
PF 70
PF 82

PF 104
PF 130

‘ * ’ - UL Listed : Certi. No. 011702-E201392    

“ ** ” – KEP CertiIC-EN. No. EN-335

CTC 19
CTC 19
CTC 19
CTC 25
CTC 31
CTC 39
CTC 51
CTC 63
CTC 75

-
-

-

NPT 1/2”
NPT 1/2”
NPT 3/4”

NPT 1

NPT 1-1/4”
NPT 1-1/2”

NPT 2”

NPT 2-1/2”

NPT 3”
NPT 4”

29.0
32.0
36.0
41.0
48.0
59.0
68.0
81.0

102.0
121.0
153.0

35.0
37.0
44.0
49.0
57.0
64.0
69.0
76.0
73.0
81.0

101.0

60.0
62.0
72.0

102.0
148.0
226.0
322.0
470.0
784.0

1,212.0
1,856.0

10 (1/2”)
12 (1/2”)
16 (1/2”)
22 (3/4”)
28 (1”)
36 (1-1/4”)
42 (1-1/2”)
54 (2”)
70 (2-1/2”)
82 (3”)
104 (4”)

CAT. NO. 

THREADS

DIMENSIONS (MM)

KFUG & 
KFUC &

*KFUT &

**KFUTE

KFUG

KFUC

KFUT

ACROSS 

CORNERS 

PROTRUSION

LENGTH 

WEIGHT 

(G/EA)

Selection Table 2 – Straight Box Female Connector

PF 16
PF 16
PF 16
PF 22
PF 28
PF 36
PF 42
PF 54
PF 70
PF 82

PF 104

‘ * ’ - UL Listed : Certi. No. 011702-E201392     

“ ** ” – KEPIC-EN Certi. No. EN-335

Electrical Conduit / Cable Trays

E40 _ E41

Electrical Condui

t/

Cable Trays

E

CTC 19
CTC 19
CTC 19
CTC 25
CTC 31
CTC 39
CTC 51
CTC 63
CTC 75

-
-

-

NPT 1/2”
NPT 1/2”
NPT 3/4”

NPT 1

NPT 1-1/4”
NPT 1-1/2”

NPT 2”

NPT 2-1/2”

NPT 3”
NPT 4”

29.0
32.0
36.0
41.0
48.0
59.0
68.0
81.0

102.0
121.0
153.0

31.0
35.0
39.0
45.0
53.0
64.0
73.0
88.0

113.0
130.0
162.0

80.0
90.0

108.0
156.0
260.0
464.0
630.0

1,042.0
1,670.0
2,461.0
4,140.0

10 (1/2”)
12 (1/2”)
16 (1/2”)
22 (3/4”)
28 (1”)
36 (1-1/4”)
42 (1-1/2”)
54 (2”)
70 (2-1/2”)
82 (3”)
104 (4”)

CAT. NO. 

THREADS

DIMENSIONS (MM)

KFAG90& 

*KFAT90&

**KFAT90E

KFUG

KFUC

KFUT

ACROSS 

CORNERS 

PROTRUSION

LENGTH 

35.0
38.0
42.0
48.0
56.0
65.0
75.0
86.0

132.0
146.0
171.0

ROTATE

RADIUS

WEIGHT 

(G/EA)

Selection Table 3 – Angle 90

°

Male Connector

PF 16
PF 16
PF 16
PF 22
PF 28
PF 36
PF 42
PF 54
PF 70
PF 82

PF 104

‘ * ’ - UL Listed : Certi. No. 011702-E201392     

“ ** ” – KEPIC-EN Certi. No. EN-335

CTC 19
CTC 19
CTC 19
CTC 25
CTC 31
CTC 39
CTC 51
CTC 63
CTC 75

-
-

-

NPT 1/2”
NPT 1/2”
NPT 3/4”

NPT 1

NPT 1-1/4”
NPT 1-1/2”

NPT 2”

NPT 2-1/2”

NPT 3”
NPT 4”

29.0
32.0
36.0
41.0
48.0
59.0
68.0
81.0

102.0
121.0
153.0

40.0
44.0
48.0
54.0
64.0
73.0
83.0
95.0

131.0
147.0
176.0

80.0

100.0
112.0
166.0
286.0
248.0
510.0
788.0

1,622.0
2,260.0
4,344.0

10 (1/2”)
12 (1/2”)
16 (1/2”)
22 (3/4”)
28 (1”)
36 (1-1/4”)
42 (1-1/2”)
54 (2”)
70 (2-1/2”)
82 (3”)
104 (4”)

CAT. NO. 

THREADS

DIMENSIONS (MM)

KFAG45& 

*KFAT45&

**KFAT45E

KFUG

KFUC

KFUT

ACROSS 

CORNERS 

PROTRUSION

LENGTH 

29.0
32.0
35.0
40.0
47.0
54.0
61.0
70.0

106.0
118.0
139.0

ROTATE

RADIUS

Selection Table 4 – Angle 45

°

Male Connector

PF 16
PF 16
PF 16
PF 22
PF 28
PF 36
PF 42
PF 54
PF 70
PF 82

PF 104

‘ * ’ - UL Listed : Certi. No. 011702-E201392     

“ ** ” – KEPIC-EN Certi. No. EN-335

WEIGHT 

(G/EA)

catalog_eng-html.html
background image

W Series for Second Class Pliable Conduit Type

Liquid-tight Conduit Fittings for Second Class Pliable Metal Conduits (KS C 8422)

KS C 8459

SAMWHA liquid-tight product line offers high-quality, high-performance fittings. Designed to the toughest
standards and integrating the latest technology, not only do you get a reliable and durable product, you also get
one that reduces installation time and cost. Our versatile lines of liquid-tight fittings are designed for a wide
range of applications.

Applications

Typical applications for liquid-tight conduit and liquid-
tight fittings include the wiring of machine tools,
motors, transformers, food processing equipment,
robotics, air conditioning units, illuminated store front
signs and billboards, etc. The pliable metallic conduit
and fittings protect conductors from mechanical
damage due to vibration and movement, and seal out
cutting oils, coolants, water, dust, etc.

Applications such as these can be found in, but are
not limited to, industries such as:

Machine tool manufacturers

Electric power generating plants

Waste treatment facilities

Paint manufacturing facilities

Automobile manufacturing facilities

Aerospace industries

Breweries

Food processing plants

Dairies

Pulp and paper mills

Petroleum refineries

Chemical and petrochemical plants

Features

Provides protection in wet locations.

Available in various configurations in various 
trade sizes.

Hex surfaces on gland nut and Thermoplastic 
elastomer sealing gasket effectively seals out 
water, oil, dust and dirt.

Lock nut bites into box.

Compliance / Approvals

KS C 8459 Fittings for flexible metal conduits

Model Number Logic

Threads size

#10~#101

Select
Constant

W

Outlet type

B : Straight male
U : Straight female
A : Angle male

0

Threads Spec.

G : BSPP Threads
C : CTC Threads
T : NPT Threads

0

00

Angle Spec.

90 :90

°

angle

0

Example 1) Straight PF threads Male 1/2” pliable #15 WBG 15
Example 2) 45

°

NPT threads Male 1-1/2” WAT 50

Standard Materials

Bodies & Nuts & Locknuts – Zinc Die Casting

Gland nut sealing ring – Neoprene or Rubber

Sealing Gasket – Neoprene or Rubber

E

WBG &  WBT
WBC

WUG & WUT 
WUC

WAG 90

°

&  WAT 90

°

WAC 90

Fitting for Flexible & Pliable Metal
Conduits Liquid Tight Fittings

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

Electrical Conduit / Cable Trays

E42 _ E43

Electrical Condui

t/

Cable Trays

E

KS C 8459

W Series for Second Class Pliable Conduit Type

Liquid-tight Conduit Fittings for Second Class Pliable Metal Conduits (KS C 8422)

CTC 19

CTC 19

CTC 19

CTC 19

CTC 25

CTC 31

CTC 39

CTC 51

CTC 63

CTC 75

-

-

-

NPT 1/2”

NPT 1/2”

NPT 1/2”

NPT 3/4”

NPT 1

NPT 1-1/4”

NPT 1-1/2”

NPT 2”

NPT 2-1/2”

NPT 3”

NPT 4”

33.0

33.0

38.0

38.0

47.0

53.0

64.0

78.0

97.0

113.0

122.0

141.0

26.0

26.0

27.0

27.0

31.0

33.0

34.0

37.0

39.0

47.0

52.0

55.0

80.0

70.0

100.0

90.0

130.0

190.0

300.0

410.0

690.0

1,070.0

1,320.0

1,710.0

10 (1/2”)

12 (1/2”)

15 (1/2”)

17 (1/2”)

24 (3/4”)

30 (1”)

38 (1-1/4”)

50 (1-1/2”)

68 (2”)

76 (2-1/2”)

83(3”)

101 (4”)

CAT. NO. 

THREADS

DIMENSIONS (MM)

WBG & 
WBC &
WBT

WBG

WBC

WBT

ACROSS 

CORNERS 

PROTRUSION

LENGTH 

WEIGHT 

(G/EA)

Selection Table 1 – Straight Box Male Connector

PF 16

PF 16

PF 16

PF 16

PF 22

PF 28

PF 36

PF 42

PF 54

PF 70

PF 82

PF 104

CTC 19

CTC 19

CTC 19

CTC 19

CTC 25

CTC 31

CTC 39

CTC 51

CTC 63

CTC 75

-

-

-

NPT 1/2”

NPT 1/2”

NPT 1/2”

NPT 3/4”

NPT 1

NPT 1-1/4”

NPT 1-1/2”

NPT 2”

NPT 2-1/2”

NPT 3”

NPT 4”

33.0

33.0

38.0

38.0

47.0

53.0

64.0

78.0

97.0

113.0

122.0

141.0

43.0

43.0

44.0

44.0

50.0

55.0

62.0

65.0

71.0

83.0

91.0

100.0

80.0

80.0

80.0

100.0

130.0

190.0

320.0

410.0

740.0

1,110.0

1,340.0

2,090.0

10 (1/2”)

12 (1/2”)

15 (1/2”)

17 (1/2”)

24 (3/4”)

30 (1”)

38 (1-1/4”)

50 (1-1/2”)

68 (2”)

76 (2-1/2”)

83(3”)

101 (4”)

CAT. NO. 

THREADS

DIMENSIONS (MM)

WUG & 
WUC &
WUT

WUG

WUC

WUT

ACROSS 

CORNERS 

PROTRUSION

LENGTH 

Selection Table 2 – Straight Box Female Connector

PF 16

PF 16

PF 16

PF 16

PF 22

PF 28

PF 36

PF 42

PF 54

PF 70

PF 82

PF 104

CTC 19

CTC 19

CTC 19

CTC 19

CTC 25

CTC 31

CTC 39

CTC 51

CTC 63

CTC 75

-

-

-

NPT 1/2”

NPT 1/2”

NPT 1/2”

NPT 3/4”

NPT 1

NPT 1-1/4”

NPT 1-1/2”

NPT 2”

NPT 2-1/2”

NPT 3”

NPT 4”

33.0

33.0

38.0

38.0

47.0

53.0

64.0

78.0

97.0

113.0

122.0

141.0

33.0

35.5

38.0

40.0

48.0

55.5

66.5

78.0

96.0

118.5

130.5

156.0

120.0

120.0

140.0

140.0

200.0

330.0

1020.0

1340.0

1120.0

1460.0

1760.0

2270.0

10 (1/2”)

12 (1/2”)

15 (1/2”)

17 (1/2”)

24 (3/4”)

30 (1”)

38 (1-1/4”)

50 (1-1/2”)

68 (2”)

76 (2-1/2”)

83(3”)

101 (4”)

CAT. NO. 

THREADS

DIMENSIONS (MM)

WAG &
WAC & 
WAT

WAG

WAC

WAT

ACROSS 

CORNERS 

PROTRUSION

LENGTH 

51.0

51.0

51.0

51.0

59.0

69.0

83.0

91.0

108.0

120.0

130.0

140.0

ROTATE

RADIUS

Selection Table 3 – Angle 90

°

Male Connector

PF 16

PF 16

PF 16

PF 16

PF 22

PF 28

PF 36

PF 42

PF 54

PF 70

PF 82

PF 104

WEIGHT 

(G/EA)

WEIGHT 

(G/EA)

catalog_eng-html.html
background image

KG Series Conduit Couplings
For Second Class Pliable Metal Conduits (KS C 8422)

KS C 8459

Applications

KG Series indoor conduit Couplings for use with all type Non liquid-tight Pliable metal conduit, providing
mechanical conduit retention and electrical continuity .

Finishes

Steel – Electro Zinc Plate

Threads size

#10~#101

Select
Constant

KG

Threads Spec.

G : BSPP Threads
C : CTC Threads
T : NPT Threads

0

00

Example 1) PF threads Male  1/2” pliable #15 KG 15
Example 2) NPT threads Male  1-1/2” KG 50

Features

Available in various configurations in various
trade sizes.

Standard Materials

Body – Stell or Stainless Steel

Compliance / Approvals

KS C 8459 Fittings for flexible metal conduits

CTC 19

CTC 19

CTC 19

CTC 19

CTC 25

CTC 31

CTC 39

CTC 51

CTC 63

CTC 75

-

-

-

NPT 1/2”

NPT 1/2”

NPT 1/2”

NPT 3/4”

NPT 1

NPT 1-1/4”

NPT 1-1/2”

NPT 2”

NPT 2-1/2”

NPT 3”

NPT 4”

26.0

26.0

26.0

26.0

33.0

40.0

50.0

62.0

76.0

90.0

95.0

120.0

37.0

37.0

37.0

40.0

44.0

49.0

56.0

56.0

70.0

73.0

78.0

87.0

63.0

80.0

50.0

40.0

70.0

120.0

90.0

140.0

220.0

290.0

253.0

491.0

10 (1/2”)

12 (1/2”)

15 (1/2”)

17 (1/2”)

24 (3/4”)

30 (1”)

38 (1-1/4”)

50 (1-1/2”)

68 (2”)

76 (2-1/2”)

83(3”)

101 (4”)

CAT. NO. 

THREADS

DIMENSIONS (MM)

KG

WBG

WBC

WBT

OUTER

DIAMETER

LENGTH 

WEIGHT (G/EA)

Selection Table

PF 16

PF 16

PF 16

PF 16

PF 22

PF 28

PF 36

PF 42

PF 54

PF 70

PF 82

PF 104

Model Number Logic

E

KG

Fitting for Flexible & Pliable Metal
Conduits Liquid Tight Fittings

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

Electrical Conduit / Cable Trays

E44 _ E45

Electrical Condui

t/

Cable Trays

E

SI Series Conduit Couplings for Communication Flexible Metal Conduit Type

For Communication Flexible Metal Conduits (KS C 8422)

Applications

SI Series indoor conduit Couplings for use with Communication Flexible metal conduit, providing mechanical conduit
retention and electrical continuity .

Threads size

#5.5~#16

Select
Constant

SI

Threads Spec.

M : Metric Threads

M

Outlet type

B : Straight male
U : Straight female

0

00

Example 1) Male  Metric M8 x 1.0 pitch SIBM 5.5
Example 2) Female  Metric M22 x 2.5 pitch SIUM 16

Features

Available in various configurations in various trade sizes.

Standard Materials

Body – Stainless Steel

13.0

14.0

16.0

18.0

21.0

23.0

22.0

23.0

26.0

29.0

35.0

39.0

#5.5

#8

#10

#12

#14

#16

CAT. NO. 

THREADS

DIMENSIONS (MM)

SIBM &
SIUM

Metric

Pitch (MM)

ACROSS CORNERS 

SIBM

SIUM

PROTRUSION LENGTH 

Selection Table

M 8

M 12

M 14

M 16

M 18

M 22

1.0

1.25

1.25

1.5

2.5

2.5

12.0

16.0

18.0

20.0

22.0

27.0

Model Number Logic

SIBM  

SIUM

Fitting for Flexible & Pliable Metal
Conduits The Others

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

MS Connector Series for Flexible Conduits With Cannon Plugs

MS Connector MAS-MS/MS Connector for Flexible Conduits with Cannon Plugs

Applications

MS Connectors can connect flexible conduit with
cannon plugs and simplify wires of connecting
circuits. Servomotors, machine tools, communication
and military equipment and aerial navigation.

MS Connector

Features

Available in various configurations in various trade sizes.

Standard Materials

Body – Stainless Steel or Nickel Plated Brass, Natural Aluminum

12

12

12

16

16

22

12

16

12

16

22

28

22

28

36

22

28

36

42

22

28

36

42

28

36

42

54

54

70

1/2. 28 UNEF

5/8. 24 UNEF

3/4. 20 UNEF

3/4. 20 UNEF

7/8. 20 UNEF

7/8. 20 UNEF

1. 20 UNEF

1. 20 UNEF

1-3/16. 18 UNEF

1-3/16. 18 UNEF

1-3/16. 18 UNEF

1-3/16. 18 UNEF

1-7/16. 18 UNEF

1-7/16. 18 UNEF

1-7/16. 18 UNEF

1-3/4. 18 UNS

1-3/4. 18 UNS

1-3/4. 18 UNS

1-3/4. 18 UNS

2. 18 UN

2. 18 UN 

2. 18 UN

2. 18 UN

2-1/4. 16 UN 

2-1/4. 16 UN

2-1/4. 16 UN

2-1/4. 16 UN

2-1/4. 16 UN

3. 16 UN

10.0

10.0

10.0

10.0

10.0

10.0

10.0

10.0

10.0

10.0

10.0

10.0

10.0

10.0

10.0

11.5

11.5

11.5

11.5

13.0

13.0

13.0

13.0

13.0

13.5

13.5

13.5

14.5

14.5

34.0

34.0

34.0

35.0

35.0

35.0

34.0

35.0

34.0

35.0

35.0

43.0

43.0

35.0

46.0

42.0

43.0

46.0

51.0

42.0

43.0

46.0

51.0

43.0

46.0

51.0

54.0

54.0

54.0

10S-12

12-12

14-12

14-16

16-16

16-22

18-22

18-16

20.22-12

20.22-16

20.22-22

20.22-28

24.28-22

24.28-28

24.28-36

32-22

32-28

32-36

32-42

36-22

36-28

36-36

36-42

40-28

40-36

40-42

40-54

44-54

48-70

SIZE

NOMINAL SIZE

MS

MS SIZE

FLEXIBLE CONDUIT

PROTRUSION

LENGTH (MM)

INTERLOCKED 

THREAD LENGTH (MM)

V.M.S CONNECTING

THREAD

Selection Table

10S

12

14

14

16

16

18

18

20.22

20.22

20.22

20.22

24.28

24.28

24.28

32

32

32

32

36

36

36

36

40

40

40

40

44

48

CANNON PLUG

FLEXIBLE CONDUIT

E

Fitting for Flexible & Pliable Metal
Conduits The Others

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

Electrical Conduit / Cable Trays

E46 _ E47

Electrical Condui

t/

Cable Trays

E

Lock Nuts

Conduit Lock Nuts

Features

Precision-machined threads allow for easy installation.

Heavy stock thickness and specially designed tabs tighten securely and 
will not easily loosen even in the most severe applications.

Standard Materials

Zinc Electro Galvanized Steel

Zinc Die Casting

KS C 8460

KS C 8459

Stainless Steel      
Only

Selection Table

CLN

#16 

#22

#28 

#36 

#42 

#54 

#70 

#82 

#92 

#104 

1/2”

3/4”

1”

1-1/4”

1-1/2”

2”

2-1/2”

3”

3-1/2”

4”

1/2”

3/4”

1”

1-1/4”

1-1/2”

2”

2-1/2”

3”

3-1/2”

4”

45.4

45.4

90.7

136.0

226.8

362.9

453.6

680.0

725.7

862.0

CAT. NO. 

THREADS

BSPP

NPS

WEIGHT

(G/10EA)

Selection Table

FUR

#16 

#22

#28 

#36 

#42 

#54 

#70 

#82 

#92 

#104 

CAT. NO. 

Ferrules 

for Liquid-tight Flexible Metal Conduit Only

Model – FUR

Zinc Die Casting 

Steel

Fitting for Flexible & Pliable Metal
Conduits Accessory

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

Application

In the electrical wiring of buildings, a cable tray system is used to support insulated electric cables used 
for power distribution and communication. 
Cable trays are used as an alternative to open wiring or electrical conduit systems, and are commonly 
used for cable management in commercial and industrial construction. They are especially useful in 
situations where changes to a wiring system are anticipated, since new cables can be installed by laying 
them in the tray, instead of pulling them through a pipe.

Standard Materials

Hot Rolled Mild Steel 
(JIS G 3101-1987 SS400, KS D 3503-82  SS41) 

Standard Finishes

Zinc Hot Dip Galvanized

Size Ranges

Width - 200mm~1,000mm

Compliances / Approvals

KS C 8464

Connecto

r

Employ 3/8” Diameter ribbed-Neck bolts and 
flanged nuts.
Order connectors, bolts and nuts as separate item.

E

CT Cable Trays

Ladder Cable Tray

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Cable Trays Ladder Series

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

Selection Table

Ladder Tray, Inside Rail  

LADDER CT22

LADDER CT23

LADDER CT32

LADDER CT33

LADDER CT42

LADDER CT43

LADDER CT52

LADDER CT53

LADDER CT62

LADDER CT63

LADDER CT72

LADDER CT73

LADDER CT82

LADDER CT83

LADDER CT92

LADDER CT93

LADDER CT102

LADDER CT103

200

300

200

300

200

300

200

300

200

300

200

300

200

300

200

300

200

300

200

300

400

500

600

700

800

900

1000

3000

3000

3000

3000

3000

3000

3000

3000

3000

CAT.NO.

WIDTH 

(MM)

RUNG SPACE 

(MM)

LENGTH

(MM)

Ladder Tray, Outside Rail 

Construction of Ladder Tray

GROUND BONDING JUMPER

SIDE RAIL

FLANGE NUT

TRA

Y W

IDTH

RUNG

SHANK BOLT

RUN

G S

PACIN

E

JOINT CONNERCTOR

Electrical Conduit / Cable Trays

E48 _ E49

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

HT Horizontal Tee  

Ladder Horizontal Tee 

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

WIDTH (MM)

B (MM)

A (MM)

R (MM)

LADDER HT23

LADDER HT26

LADDER HT29

LADDER HT33

LADDER HT36

LADDER HT39

LADDER HT43

LADDER HT46

LADDER HT49

LADDER HT53

LADDER HT56

LADDER HT59

LADDER HT63

LADDER HT66

LADDER HT69

LADDER HT73

LADDER HT76

LADDER HT79

LADDER HT83

LADDER HT86

LADDER HT89

LADDER HT93

LADDER HT96

LADDER HT99

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

1000

1600

2200

1100

1700

2300

1200

1800

2400

1300

1900

2500

1400

2000

2600

1500

2100

2700

1600

2200

2800

1700

2300

2900

600

900

1200

700

1000

1300

800

1100

1400

900

1200

1500

1000

1300

1600

1100

1400

1700

1200

1500

1800

1300

1600

1900

200

300

400

500

600

700

800

900

HC Horizontal Cross  

Ladder  Horizontal Cross

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

WIDTH (MM)

B (MM)

A (MM)

R (MM)

LADDER HC23

LADDER HC26

LADDER HC29

LADDER HC33

LADDER HC36

LADDER HC39

LADDER HC43

LADDER HC46

LADDER HC49

LADDER HC53

LADDER HC56

LADDER HC59

LADDER HC63

LADDER HC66

LADDER HC69

LADDER HC73

LADDER HC76

LADDER HC79

LADDER HC83

LADDER HC86

LADDER HC89

LADDER HC93

LADDER HC96

LADDER HC99

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

1000

1600

2200

1100

1700

2300

1200

1800

2400

1300

1900

2500

1400

2000

2600

1500

2100

2700

1600

2200

2800

1700

2300

2900

600

900

1200

700

1000

1300

800

1100

1400

900

1200

1500

1000

1300

1600

1100

1400

1700

1200

1500

1800

1300

1600

1900

200

300

400

500

600

700

800

900

E

Cable Trays Ladder Series

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

Electrical Conduit / Cable Trays

E50 _ E51

HE90  

Horizontal Elbow

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

WIDTH (MM)

A (MM)

R2 (MM)

R1 (MM)

LADDER HE90 23

LADDER HE90 26

LADDER HE90 29

LADDER HE90 33

LADDER HE90 36

LADDER HE90 39

LADDER HE90 43

LADDER HE90 46

LADDER HE90 49

LADDER HE90 53

LADDER HE90 56

LADDER HE90 59

LADDER HE90 63

LADDER HE90 66

LADDER HE90 69

LADDER HE90 73

LADDER HE90 76

LADDER HE90 79

LADDER HE90 83

LADDER HE90 86

LADDER HE90 89

LADDER HE90 93

LADDER HE90 96

LADDER HE90 99

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

500

800

1100

600

900

1200

700

1000

1300

800

1100

1400

900

1200

1500

1000

1300

1600

1100

1400

1700

1200

1500

1800

600

900

1200

700

1000

1300

800

1100

1400

900

1200

1500

1000

1300

1600

1100

1400

1700

1200

1500

1800

1300

1600

1900

200

300

400

500

600

700

800

900

HE60  

Horizontal Elbow

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

WIDTH (MM)

A (MM)

R2 (MM)

R (MM)

LADDER HE60 23

LADDER HE60 26

LADDER HE60 29

LADDER HE60 33

LADDER HE60 36

LADDER HE60 39

LADDER HE60 43

LADDER HE60 46

LADDER HE60 49

LADDER HE60 53

LADDER HE60 56

LADDER HE60 59

LADDER HE60 63

LADDER HE60 66

LADDER HE60 69

LADDER HE60 73

LADDER HE60 76

LADDER HE60 79

LADDER HE60 83

LADDER HE60 86

LADDER HE60 89

LADDER HE60 93

LADDER HE60 96

LADDER HE60 99

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

500

800

1100

600

900

1200

700

1000

1300

800

1100

1400

900

1200

1500

1000

1300

1600

1100

1400

1700

1200

1500

1800

410

670

930

410

670

930

410

670

930

410

670

930

410

670

930

410

670

930

410

670

930

410

670

930

200

300

400

500

600

700

800

900

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

HE45  

Horizontal Elbow

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

WIDTH (MM)

A (MM)

R2 (MM)

R1 (MM)

LADDER HE45 23

LADDER HE45 26

LADDER HE45 29

LADDER HE45 33

LADDER HE45 36

LADDER HE45 39

LADDER HE45 43

LADDER HE45 46

LADDER HE45 49

LADDER HE45 53

LADDER HE45 56

LADDER HE45 59

LADDER HE45 63

LADDER HE45 66

LADDER HE45 69

LADDER HE45 73

LADDER HE45 76

LADDER HE45 79

LADDER HE45 83

LADDER HE45 86

LADDER HE45 89

LADDER HE45 93

LADDER HE45 96

LADDER HE45 99

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

500

800

1100

600

900

1200

700

1000

1300

800

1100

1400

900

1200

1500

1000

1300

1600

1100

1400

1700

1200

1500

1800

383

595

808

383

595

808

383

595

808

383

595

808

383

595

808

383

595

808

383

595

808

383

595

808

200

300

400

500

600

700

800

900

HE30  

Horizontal Elbow

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

WIDTH (MM)

A (MM)

R2 (MM)

R1 (MM)

LADDER HE30 23

LADDER HE30 26

LADDER HE30 29

LADDER HE30 33

LADDER HE30 36

LADDER HE30 39

LADDER HE30 43

LADDER HE30 46

LADDER HE30 49

LADDER HE30 53

LADDER HE30 56

LADDER HE30 59

LADDER HE30 63

LADDER HE30 66

LADDER HE30 69

LADDER HE30 73

LADDER HE30 76

LADDER HE30 79

LADDER HE30 83

LADDER HE30 86

LADDER HE30 89

LADDER HE30 93

LADDER HE30 96

LADDER HE30 99

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

500

800

1100

600

900

1200

700

1000

1300

800

1100

1400

900

1200

1500

1000

1300

1600

1100

1400

1700

1200

1500

1800

337

487

687

337

487

687

337

487

687

337

487

687

337

487

687

337

487

687

337

487

687

337

487

687

200

300

400

500

600

700

800

900

E

Cable Trays Ladder Series

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

Electrical Conduit / Cable Trays

E52 _ E53

VT Series  

Vertical Tee

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

WIDTH (MM)

B (MM)

A (MM)

R (MM)

LADDER VT 23

LADDER VT 26

LADDER VT 29

LADDER VT 33

LADDER VT 36

LADDER VT 39

LADDER VT 43

LADDER VT 46

LADDER VT 49

LADDER VT 53

LADDER VT 56

LADDER VT 59

LADDER VT 63

LADDER VT 66

LADDER VT 69

LADDER VT 73

LADDER VT 76

LADDER VT 79

LADDER VT 83

LADDER VT 86

LADDER VT 89

LADDER VT 93

LADDER VT 96

LADDER VT 99

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

1000

1600

2200

1100

1700

2300

1200

1800

2400

1300

1900

2500

1400

2000

2600

1500

2100

2700

1600

2200

2800

1700

2300

2900

400

700

1000

400

700

1000

400

700

1000

400

700

1000

400

700

1000

400

700

1000

400

700

1000

400

700

1000

200

300

400

500

600

700

800

900

VC Series  

Vertical Cross

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

WIDTH (MM)

A (MM)

R (MM)

LADDER VC 23

LADDER VC 26

LADDER VC 29

LADDER VC 33

LADDER VC 36

LADDER VC 39

LADDER VC 43

LADDER VC 46

LADDER VC 49

LADDER VC 53

LADDER VC 56

LADDER VC 59

LADDER VC 63

LADDER VC 66

LADDER VC 69

LADDER VC 73

LADDER VC 76

LADDER VC 79

LADDER VC 83

LADDER VC 86

LADDER VC 89

LADDER VC 93

LADDER VC 96

LADDER VC 99

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

1000

1600

2200

1100

1700

2300

1200

1800

2400

1300

1900

2500

1400

2000

2600

1500

2100

2700

1600

2200

2800

1700

2300

2900

200

300

400

500

600

700

800

900

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

VE90  

Vertical Elbow

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

WIDTH (MM)

A (MM)

R (MM)

LADDER VE90 23

LADDER VE90 26

LADDER VE90 29

LADDER VE90 33

LADDER VE90 36

LADDER VE90 39

LADDER VE90 43

LADDER VE90 46

LADDER VE90 49

LADDER VE90 53

LADDER VE90 56

LADDER VE90 59

LADDER VE90 63

LADDER VE90 66

LADDER VE90 69

LADDER VE90 73

LADDER VE90 76

LADDER VE90 79

LADDER VE90 83

LADDER VE90 86

LADDER VE90 89

LADDER VE90 93

LADDER VE90 96

LADDER VE90 99

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

400

700

1000

400

700

1000

400

700

1000

400

700

1000

400

700

1000

400

700

1000

400

700

1000

400

700

1000

200

300

400

500

600

700

800

900

VE60  

Vertical Elbow

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

WIDTH (MM)

B (MM)

A (MM)

R (MM)

LADDER VE60 23

LADDER VE60 26

LADDER VE60 29

LADDER VE60 33

LADDER VE60 36

LADDER VE60 39

LADDER VE60 43

LADDER VE60 46

LADDER VE60 49

LADDER VE60 53

LADDER VE60 56

LADDER VE60 59

LADDER VE60 63

LADDER VE60 66

LADDER VE60 69

LADDER VE60 73

LADDER VE60 76

LADDER VE60 79

LADDER VE60 83

LADDER VE60 86

LADDER VE60 89

LADDER VE60 93

LADDER VE60 96

LADDER VE60 99

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

410

670

930

410

670

930

410

670

930

410

670

930

410

670

930

410

670

930

410

670

930

410

670

930

236

386

536

236

386

536

236

386

536

236

386

536

236

386

536

236

386

536

236

386

536

236

386

536

200

300

400

500

600

700

800

900

Outside Type

Inside Type

Outside Type

Inside Type

In 90

°

Out 60

°

E

Cable Trays Ladder Series

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

VE45  

Vertical Elbow

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

WIDTH (MM)

B (MM)

A (MM)

R (MM)

LADDER VE45 23

LADDER VE45 26

LADDER VE45 29

LADDER VE45 33

LADDER VE45 36

LADDER VE45 39

LADDER VE45 43

LADDER VE45 46

LADDER VE45 49

LADDER VE45 53

LADDER VE45 56

LADDER VE45 59

LADDER VE45 63

LADDER VE45 66

LADDER VE45 69

LADDER VE45 73

LADDER VE45 76

LADDER VE45 79

LADDER VE45 83

LADDER VE45 86

LADDER VE45 89

LADDER VE45 93

LADDER VE45 96

LADDER VE45 99

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

383

595

808

383

595

808

383

595

808

383

595

808

383

595

808

383

595

808

383

595

808

383

595

808

158

246

334

158

246

334

158

246

334

158

246

334

158

246

334

158

246

334

158

246

334

158

246

334

200

300

400

500

600

700

800

900

VE30  

Vertical Elbow

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

WIDTH (MM)

B (MM)

A (MM)

R (MM)

LADDER VE30 23

LADDER VE30 26

LADDER VE30 29

LADDER VE30 33

LADDER VE30 36

LADDER VE30 39

LADDER VE30 43

LADDER VE30 46

LADDER VE30 49

LADDER VE30 53

LADDER VE30 56

LADDER VE30 59

LADDER VE30 63

LADDER VE30 66

LADDER VE30 69

LADDER VE30 73

LADDER VE30 76

LADDER VE30 79

LADDER VE30 83

LADDER VE30 86

LADDER VE30 89

LADDER VE30 93

LADDER VE30 96

LADDER VE30 99

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

300

600

900

337

487

687

337

487

687

337

487

687

337

487

687

337

487

687

337

487

687

337

487

687

337

487

687

90

130

170

90

130

170

90

130

170

90

130

170

90

130

170

90

130

170

90

130

170

90

130

170

200

300

400

500

600

700

800

900

Electrical Conduit / Cable Trays

E54 _ E55

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

RDS / RDR / RDL  

Reducer

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

Straight

Right

CAT.NO.

Left

WIDTH 1

(MM)

WIDTH 2

(MM)

LADDER RDS 3020

LADDER RDS 4020

LADDER RDS 4030

LADDER RDS 5030

LADDER RDS 5040

LADDER RDS 6030

LADDER RDS 6040

LADDER RDS 7030

LADDER RDS 7060

LADDER RDS 8030

LADDER RDS 8060

LADDER RDS 9030

LADDER RDS 9060

LADDER RDS 1030

LADDER RDS 1060

LADDER RDR 3020

LADDER RDR 4020

LADDER RDR 4030

LADDER RDR 5030

LADDER RDR 5040

LADDER RDR 6030

LADDER RDR 6040

LADDER RDR 7030

LADDER RDR 7060

LADDER RDR 8030

LADDER RDR 8060

LADDER RDR 9030

LADDER RDR 9060

LADDER RDR 1030

LADDER RDR 1060

LADDER RDL 3020

LADDER RDL 4020

LADDER RDL 4030

LADDER RDL 5030

LADDER RDL 5040

LADDER RDL 6030

LADDER RDL 6040

LADDER RDL 7030

LADDER RDL 7060

LADDER RDL 8030

LADDER RDL 8060

LADDER RDL 9030

LADDER RDL 9060

LADDER RDL 1030

LADDER RDL 1060

300

400

500

600

700

800

900

1000

200

200

300

300

400

300

400

300

600

300

600

300

600

300

600

E

Cable Trays Ladder Series

Electrical Conduit / Cable Trays

Straight Hand Reducer

Left Hand Reducer

Right Hand Reducer

catalog_eng-html.html
background image

Selection Table

Straight

Horizontal

CAT.NO.

Vertical

SIDERAIL

(MM)

DEPTH

(MM)

LADDER TSS 75

LADDER TSS 100

LADDER TSS 150

LADDER TSH 75

LADDER TSH 100

LADDER TSH 150

LADDER TSV 75

LADDER TSV 100

LADDER TSV 150

45

75

120

50

100

150

200

250

300

350

400

450

550

700

75

100

150

TSS / TSR / TSL  

Tray Separator

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

RC  

Reducing Connector

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Selection Table

CAT.NO.

RN (MM)

LADDER RC 50

LADDER RC 100

LADDER RC 150

LADDER RC 200

LADDER RC 250

LADDER RC 300

LADDER RC 350

LADDER RC 400

LADDER RC 450

LADDER RC 550

LADDER RC 700

Electrical Conduit / Cable Trays

E56 _ E57

Straight seperator 

Vertical seperator

Horizontal seperator

Straight Type

Left Hand Type

Rigft Hand Type

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

BC  

Box Connector

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

200

300

400

500

600

700

800

900

1000

Selection Table

CAT.NO.

W (MM)

LADDER BC 20

LADDER BC 30

LADDER BC 40

LADDER BC 50

LADDER BC 60

LADDER BC 70

LADDER BC 80

LADDER BC 90

LADDER BC 100

AHC  

Adjustable Horizontal Connector

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

75

100

150

Selection Table

CAT.NO.

H (MM)

LADDER AHC 75

LADDER AHC 100

LADDER AHC 150

ARC 

Ladder Adjustable Riser Connector

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

75

100

150

Selection Table

CAT.NO.

H (MM)

LADDER ARC 75

LADDER ARC 100

LADDER ARC 150

E

Cable Trays Ladder Series

Electrical Conduit / Cable Trays

catalog_eng-html.html
background image

Selection Table

CAT.NO.

L TYPE

C TYPE

H (MM)

LADDER JCC 75

LADDER JCC 100

LADDER JCC 150

LADDER JCL 75

LADDER JCL 100

LADDER JCL 150

200

300

400

500

600

700

800

900

1000

Selection Table

CAT.NO.

W (MM)

LADDER EC 20

LADDER EC 30

LADDER EC 40

LADDER EC 50

LADDER EC 60

LADDER EC 70

LADDER EC 80

LADDER EC 90

LADDER EC 100

JC  

Joint Connector

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

EJC  

Expansion Joint Connector

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

EC 

End Cap

KS C 8464 
(Cable Tray)

KS D 8308 

(Hot Dip Galvanized)

Electrical Conduit / Cable Trays

E58 _ E59

75

100

150

Selection Table

CAT.NO.

L TYPE

C TYPE

H (MM)

LADDER EJCC 75

LADDER EJCC 100

LADDER EJCC 150

LADDER EJCL 75

LADDER EJCL 100

LADDER EJCL 150

75

100

150

Electrical Condui

t/

Cable Trays

E

catalog_eng-html.html
background image

UL and Explosion-proof Certified Products

Terminal blocks are essential for ultimate safety in I&C and electrical connection, 

installing convenience as well.  As UL and explosion-proof certified products, 

Samwha’s terminal blocks always provide the best solution.  

catalog_eng-html.html
background image

Smart  +  Technology  +  Human

F

F

Controls/
Terminal Blocks

Contents

Controls / Terminal Blocks

UE Series  Hazardous Control Devices
CXS Series  Special Cam Switches (IEC 947-3)
HML Series  Mono Lever Switches

Control / Terminal Blocks

Industrial & Hazardous Area Terminal Block General 
Technical Description
SAMWHA Industrial & Hazardous Area Terminal Block

Terminal Blocks for Industry

Lug-Less Type Lugless Terminal Block (Component)
Ring Lug Type Ring Lug Terminal Block (Component)
Ring Lug Section Type NUCLEAR CLASS 1E Ring  Lug
SECTIONAL Terminal Block (Component)
Bus Bar Section Type  Nuclear Class 1E Bus  Bar Terminal
Block (Component)

Terminal Blocks for Hazardous Area

Lugless Increased Safety Ex e II Type Terminal Block
(Component)
Ring Lug  Increased Safety Ex e II Type Terminal Block
(Component)

Accessories

End Plate EP End Plate
End Stopper  ESS & ESL  End Stopper
Mounting Rail  TS 32 & TS 35 Mounting Rail
Support Bracket 
Marking Tag  RM5  Marking Tag
Fixed Base

F2
F6
F16

F18
F22

F23

F25

F26

F27

F29

F30

F31
F31
F31
F31
F32
F32

Controls

catalog_eng-html.html
background image

F

Applications

UE Series are used with Control Panel (Ex d II B+H2 or II C) or Control Box (Ex d II B+H2 ) :

For Zone 1&2, Flame Proof type (Ex d II B+H2 or Ex d II C)

Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations

Where exposure to frequent or heavy rain, water, spray, moisture, and humidity is common ; such as :          

offshore drilling facilities, cooling towers, coal  preparation and handling facilities and sewage and 
waste water treatment plant.

In areas which are hazardous due to the presence of hydrogen or gases and vapors of equivalent hazard 

such as  found in process industries, gas manufacturing plants.

Features

IP 65 grade with seal type lock nut

Lower installation cost 
Installation is a one person job. The devices fit into M30 x 1.5 pitch or M30 x 2 pitch* tapping hole, are 
secured by tightening the seal type lock nut.

These can be easily replaced in the field and custom  engraving is available.

LED (Light Emitting Diode) Pilot lights

UEL & UELC provide reliable indication for 100,000 hours (half life). These will continue to operate for many 
years, are shock and vibration resistant and have a low power consumption.

Pushbutton & Selector Switches have 1 normally open contact and 1 normally closed contact. 
Additional configurations are available, contact SAMWHA.

Standard Materials

Brass

UE Series

Hazardous Control Devices

Explosion-proof / Rain-tight / Water-tight
Corrosion  Resistant

Cl. I, Div. 1 & 2, Groups A*, B, C, D / NEMA 4, 4X   

/ II 2G Ex d II C* or II B+H2 IP 65

Standard Finishes

Body : Natural or Nickel Plated       

Cap & Handle : Chrome Plated

Certification

Certified KOSHA (Korea Occupational Safety & Health Agency)

Compliances

IEC 60079-0 Equipment - General requirements

IEC 60079-1 Equipment protection by flameproof enclosures “d”

ISO 261 Metric screw threads 

NEC 500       

NEMA 4, 4X        

IEC 60529

UEL & UELC* 

UEBL

UEB & UEBC*

UEE

UES & UESC* 

UEC

UECC* UEZC* UEAC*

UEVC*

Controls

Controls / Terminal Blocks

catalog_eng-html.html
background image

Controls / Termonal Blocks

F2_ F3

Technical Data

Model Number Logic

Unit Spec.

BL : Pilot light & Push Button
B : Push Button
E : Emergency switch
S : Selector switch
C : Cam switch
ZC* : Buzzer
SC* : Selector switch II C type
LC* : Pilot light II C type
BC* : Push Button II C type
CC* : Cam switch II C type
AC* : Ampere meter
VC* : Volt meter

Voltage

@

60Hz

11 - AC110V
12 - DC12V
22 - AC220V
24 - DC24V

Example 1) Push Button Lamp AC220V Green UEBL 22 GR
Example 2) Pilot Lamp AC 110V  Yellow UEL 11 YL

Color

RD - Red
GR - Green
YL - Yellow
WT - White
BU - Blue

Series 
Constant

UE

NO
NC
NO
NC
NO
NC
NO
NC
NO
NO
NO
NC
NO
NC
NO
NO
NO
NO





















































































1

2

3

4

5

6

7

8

9

10

11

12

13

UEL

UEBL

UEB

UEE

UES

UEC

UEZC*

UESC*

UELC*

UEBC*

UECC*

UEAC*

UEVC*

1a1b

1a1b

1a1b

1a1b

2a

2a2b

4a

UEE

UEB &UEBC*

UEBL

UES &UESC*

Pilot Light

Pilot Lamp & Push Button

Push Button

Emergency Switch

Selector Switch

Cam Switch

Buzzer

Selector Switch

Pilot Lights

Push Button

Cam Switch

Ampare Meter

Volt Meter

Ex d II B+H2

DC12, 24V, 

AC110, 220V

DC12, 24V 

AC110, 220V

AC110, 220V

Max 5A

AC600V

UEC & UECC are custom build type, refer to CXS Series cam switches.

Max 5A

Max 3A

M63 x1.5p

M30 x 1.5p

M30 x1.5p

AC600V

Ex d II C

UE

OO

NO

Name

Ex grade

Model No.

Rated Voltage

Rated Current

Remarks

Contact Form Chart

Model

Contact Form

Terminal Code

2 stages

Left

Right

Left

Center

Right

3 stages

OO

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

Dimensions

F

UE Series

Hazardous Control Devices

Explosion-proof / Rain-tight / 
Water-tight / Corrosion  Resistant

Cl. I, Div. 1 & 2, Groups A*, B, C, D /
NEMA 4, 4X /II 2G Ex d II C* or II B+H2 IP 65

Controls

Controls / Terminal Blocks

UER

UEL & UELC* 

UEBL

UEZC* 

UEC

catalog_eng-html.html
background image

Controls / Termonal Blocks

F4_ F5

UECC* 

UEBC* 

UEE

UES & UESC* 

UEVC* & UEAC* 

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

Special Cam Switches CXS Series Features

SAMWHA CXS Series Cam Switches are used for non hazardous area. 

Functionally voltmeter switches, ammeter switches, volt ammeter switches, control switches, 

selector switches and also by made to order special types are available.

Custom build type.

For max. 12 grips with 24 contacts and 5A.

A variety of handles are available.

Switch Positions

Manual return type are capable for up to max. 

12 grips with diverse angles of 30

°

, 45

°

, 60

°

, 90

°

providing various positions.

Manual return 30° positions

CXS Series  

Special Cam Switches (IEC 947-3)

IEC 947-3

M301

M302

M303

M304

M305

M306

M307

M308

M309

M310

M311

M312

M313

M314

M315

M316

M317

M318

M319

M320

M321

M322

M323

M324

M325

M326

M327

M328

M329

M330

M331

M332

M333

M334

M337

M338

M339

M340

M335

M336

M341

M342

M343

M344

M345

M346

M347

M348

M349

M350

M351

M352

M353

M354

M355

M356

M357

M358

Manual return 45

°

positions

M401

M402

M403

M404

M405

M406

M407

M408

M409

M410

M411

M412

M413

M414

M415

M416

M417

M418

M419

M420

M421

M422

M423

M424

M425

M426

F

Controls

Controls / Terminal Blocks

catalog_eng-html.html
background image

Manual return 60

°

positions

M601

M602

M603

M604

M605

M606

M607

M608

M609

M610

M611

M612

M613

M614

M615

M616

M617

M618

M619

M620

M621

M622

M623

M624

Manual return 90

°

positions

M901

M902

M903

M904

M905

M906

Spring return 30

°

positions

S301

S302

S303

S304

S305

S306

90

°

Manual retum & Spring 30

°

positions

H901

H902

H903

H904

H905

H906

H907

H908

H909

H910

H911

H912

H913

H914

H915

H916

H917

H918

H919

Spring return type are capable for up to max. 6 grips with 90

°

manual and 30

°

spring return, 

providing various positions.

Controls / Termonal Blocks

F6_ F7

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

Standard Functions

Volt-meter Switches (V/S)

CVS-2W
1

Ø

2W

CXS Series  

Special Cam Switches (IEC 947-3)

IEC 947-3

1phase 2 wires.
1phase to neutral.

1 stages

2 stages

4 stages

2 stages

3 stages

CVS -3W
3

Ø

3W 2PT

3 phase 3 wires.
3 phase to neutral
With 2 potential
Transformers.

CVS-3WT
3

Ø

3W 3PT

3 phase 3 wires.
3 phase to neutral
With 3 potential
Transformer.

CVS-3WD
3

Ø

3W

2 lines
3 phase 3wires.
2 separates
3 phase to phase 
with center OFF.

CVS-4W
3

Ø

4W 3PT

3 phase 4 wires.
3 phase to neutral
With 3 potential
Transformers.

CVS-34W
3

Ø

3&4W

3 phase 3 & 4 wires.
3 phase to phase and 
3 phases to neutral
with center OFF.

TYPE OF FUNCTION

ESCUTCHEON PLATE

CONNECTING DIAGRAM

V401

V402

V903

V904

V405

V406

V307

V308

A409

A410

V311

V312

F

Controls

Controls / Terminal Blocks

catalog_eng-html.html
background image

Ampere-meter Switches (A/S)

CAS-2W
1

Ø

2W 1CT

1 phase 2 wires.
1 current transformers.

1 stages

3 stages

2 stages

CAS-2WL
1

Ø

2W 2CT

1 phase 2 wires.
2 current transformers.

CAS-WL
3

Ø

3W 2CTW

(2stages)

3

Ø

3W 2CT

(5stages)

3 phase 3 wires.
2 current transformers.

CAS-3WT
3

Ø

3W 3CT

3 phase 3 wires.
3 current transformers.

TYPE OF FUNCTION

ESCUTCHEON PLATE

CONNECTING DIAGRAM

A401

A402

A903

A904

A405

A406

A907

A908

A409

A410

5 stages

3 stages

Controls / Termonal Blocks

F8_ F9

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

CAS-3WK
3

Ø

3W 3CT

CXS Series  

Special Cam Switches (IEC 947-3)

IEC 947-3

3 phase 3 wires.
3 current transformers.

CAS-4W
3

Ø

4W 3CT

3 phase 4 wires.
3 current transformers.

CAS-4WN
3

Ø

4W 3CT

3 phase 4 wires.
3 current transformers.
5 step switch with
neutral position.

CAS-4WL
3

Ø

4W 3CT

3 phase 4 wires.
3 current transformers.
5 step switch with
neutral position.

CVAS-4W
3

Ø

4W 3PT & CT

3 phases voltage
3 phases current 
4 wires.
3 potential 
transformers and
current transformers.

TYPE OF FUNCTION

ESCUTCHEON PLATE

CONNECTING DIAGRAM

A409

A410

A411

A412

VA403

VA404

Volt & Ampere-meter Switches (VA/S)

TYPE OF FUNCTION

ESCUTCHEON PLATE

CONNECTING DIAGRAM

5 stages

3 stages

3 stages

6 stages

5 stages

F

Controls

Controls / Terminal Blocks

Standard Functions

Ampere-meter Switches (A/S)

catalog_eng-html.html
background image

4 stages

5 stages

CVAS-3W
3

Ø

3W 2PT & CT

3 phases voltage
3 phases current 
3 wires.
2 potential 
transformers and
current transformers.

CVAS-3WT
3

Ø

3W 3PT & CT

3 phases voltage
3 phases current 
3 wires.
3 potential 
transformers and
current transformers.

VA401

VA402

Volt & Ampere-meter Switches (VA/S)

TYPE OF FUNCTION

ESCUTCHEON PLATE

CONNECTING DIAGRAM

1 stages

2 stages

1 stages

2 stages

1 stages

CCS-211S

Stop switch with 
spring return from
STOP position

C301

C302

1 stages

C303

C304

C305

C306

C307

C308

C309

C310

Control Switch (C/S)

TYPE OF FUNCTION

ESCUTCHEON PLATE

CONNECTING DIAGRAM

CCS-212S

CCS-313S

CCS-324S

CCS-315S

CCS-326S

Start switch with 
spring return from
START position

Circuit breaker 
control switch.
Stop-start switch 
with spring return 
from STOP and 
START positions.

Controls / Termonal Blocks

F10_ F11

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

IEC 947-3

2 stages

3 stages

1 stages

C911

C912

TYPE OF FUNCTION

ESCUTCHEON PLATE

CONNECTING DIAGRAM

CCS-311H

Stop-start switch with
spring return from
START to RUN

2 stages

C913

C914

4 stages

C417

C418

6 stages

C419

C420

6 stages

C421

C422

C415

C416

CCS-522H

Stop-start switch 
with spring return
to RUN for 2 units

CCS-321M

Motor reversing 
switch
1 phase 2 wires.

CCS-332M

Motor reversing 
switch
3 phase 3 wires.

CCS-343M

Pole-changing in 
two-speed 
motors with one
winding.
3 phase 3 wires.
Pos1 : low speed
Pos2 : high speed

CCS-464M

Pole-changing in 
three-speed 
motors with two
windings and one
common winding 
for speed 1 and 2.
3 phase 3 wires.

CCS-464M

Pole-changing 
and reversing of 
two-speed 
motors with one
winding. 
3 phase 3 wires.
Pos1 : low speed
Pos2 : high speed

CXS Series  

Special Cam Switches (IEC 947-3)

F

Controls

Controls / Terminal Blocks

Standard Functions

catalog_eng-html.html
background image

Handles

Round type (RHS, RHL)

Square type (SHS, SHL)

Chrysanthemum (CHS, CHL)

Oval type (OHS)

Pistol type (PHL)

Pad lock type (LHL)

Accessories

RS - 35

Ø⇒

For 35

Ø

RS - 42

Ø⇒

For 42

Ø

Inner (C 101)

Outer (C 103)

Face Ring

Connecting Link

Controls / Termonal Blocks

F12_ F13

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

IEC 947-3

Shaft Sealing Cover

Face Plate

C 104  

Small type

C 105  

Large type

Shaft Sealing Cover

SPS 

48*48

SPL 

64*64

Square type

RPS 

48*64

RPL 

64*80

Rectangular type

Technical Data

Rated  insulation  voltage (UL/CSA)

Thermal rated current (UL/CSA)

600V

12A

600V

20A

Rated  Operating Currents in Accordance with UL & CSA

In AC 11 duty, P.F = 0.7

Switching of control devices, contactors, valves etc

110~120V        8A
220~250V        6A
380~440V        4A

600V               2A

3 phase 3 pole

1 phase 2 pole

120V
240V

480~600V

120V

240~277V

1HP
2HP
5HP

0.5HP

1HP

3 phase 3 pole

1 phase 2 pole

120V
240V

480~600V

120V

240~277V

0.5HP

1HP
2HP

0.16HP
0.33HP

20A normal

Ratings in Accordance with UL & CSA

Direct-on-line starting, 

and switching during running

Direct-on-line starting, inching, 

plugging and reversing

Standard motor load Direct-on-line rating

Heavy motor load-reversing

48V                    12A
60V                    3.8A

110V                  0.85A
220V                  0.35A
440V                  0.27A

24V
30V
48V
60V

110V

12A

5A
2A

0.8A

0.35A

DC Switching Capacity

DC 1 resistive loads T

1ms

Inductive loads T=50ms

Fuse Capacity For Short-Circuit Protection

Max. permissible rated current for protective 

fuse at a prospective short-circuit.

2.5

(13 AWG)

2.5

(13 AWG)

Max. Contact Cross Section

One or more wires

Flexible wire (with sleeve)

-30

to + 70

-50

to + 95

Ambient Temperature Range

Continuous

Short-term

50% or below

90% or below

Ambient Humidity

At the temperature +40

At the temperature +20

60Hz, 2500Vac. For 1 min.

Dielectric Strength

Between live parts of opposite parity

Between live parts and exposed 
dead metal parts

CXS Series  

Special Cam Switches (IEC 947-3)

F

Controls

Controls / Terminal Blocks

catalog_eng-html.html
background image

Shock

Applied  shock value

Direction of shock

At 500Vac, 100M

or above

Insulation Resistance

Between live parts of opposite parity

Between live parts and exposed dead metal parts

1 million operations or above

100,000 operations or above

490

/s

²

3-axis of up-down, forward-backward and right-left.

Insulation Distance

Clearance distance

Creepage distance

6mm or above

8mm or above

Vibration

Oscillation frequency

Complex oscillation width

Direction of oscillation

10~55Hz
4mm
3-axis of up-down, forward-backward and right-left.

Service Life

Mechanical life

Electrical life

20kgf. 

, For 1 min.

5kgf. 

, For 5 sec.

6~8kgf. 

Strength & Operating Force

Strength

Operating force

Operating part

Terminal part

Model Number Logic

Unit Spec.

AS : Ampere 

meter Switch

VS : Volt meter 

Switch

VAS : Volt Ampere 

meter Switch

CS : Control Switch

Face Plate

SPS : Square 48
SPL : Square 64
RPS : Rectangle 

48*64

RPL : Rectangle 

64*80

Example 1) Volt Ampere meter Switch, 3

Ø

3W 3PT & CT, Manual 402, Rectangle 48*64, Pistol handle   CVAS - 3WT (M402), RPS  PHL

Example 2) Volt meter Switch, 1

Ø

2W, Manual 401, Square 48, Pad lock handle CVS - 2W (M401), SPS  LHL

Handles

RHS, RHL : Round type
SHS, SHL : Square type
CHS,CHL : 
Chrysanthemum type
OHS : Oval type
PHL : Pistol type
LHL : Pad lock type

Series 
Constant

OO

C

Standard Switch Type

by Standard Switch
Functions

Switching Position

M3xx : 30

°

Manual

M4xx : 45

°

Manual

M6xx : 60

°

Manual

M9xx : 90

°

Manual

S3xx : 30

°

Spring return

H9xx : 90

°

Spring return

OOO

(

OOO

)

OOO

OOO

Controls / Termonal Blocks

F14_ F15

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

Features

Available in 2-, 3-, and 4-positions.

Maintained and spring return 
modes available.

Models available with interlock 
mechanism to prevent inadvertent actuation.

Contact Block
Rated for 600V,
10A - 30

Ø

Specifications

600Vac / Vdc

10A

Over 500,000 operations

110Vdc : 3A

24Vac / Vdc : 10A

120Vac : 10A

240Vac : 6A
480Vac : 2A
600Vac : 1A

OPERATING TEMPERATURE

INSULATION RESISTANCE

RATED VOLTAGE : 
CURRENT

INSULATION VOLTAGE

RATED THERMAL CURRENT
ELECTRICAL LIFE

CONTACT 
RATING

Lever Directions

UP-Down

Right-Left

Up-Right-Down

Up-Left-Down

Up-Right-Left

Down-Right-Left

21

22

31

32

33

34

40

3 Ways

2 Ways

Cross 4 Ways

Contact Blocks 

Operator 

Complete Part

+

=

CONTACT ARRANGEMENT

PART NUMBER

2 NO contacts  

1 NO & 1 NC contact

2 NC contacts

LB 20

LB 11

LB 02

The contact block contains two pairs of double-break silver contacts, 
available with 1NO-1NC, 2NO, 2NC contacts. Up to four contact blocks
can be mounted on an operating base.

Replacement Parts

Bellows

Knob(Ball)

Standard Mono Lever Operators

Standard  Lever

Short Lever

Interlocking Lever

HML Series  

Mono Lever Switches

F

Controls

Controls / Terminal Blocks

-25

to 50

(without freezing)

100

Mono Lever Switches (Sub - Assembled)

ML Contact Blocks

catalog_eng-html.html
background image

Controls / Termonal Blocks

F16_ F17

Model Number Logic

Series 
Constant

OO

HML

Lever Returns

M : Manual return
S  : Spring return

O

Lever Length

X : Short type
Y : Std. type

Contacts on Each Way (UP, Right, 
Down, Left)

00 : None
10 : 1 NO
01 : 1 NC
11 : 1NO - 1NC
20 : 2NO
02 : 2NC

O

Lever Handle Color

B : Black
G : Green
R : Red

O

O

O

O

O

Lever Center Locking

L : With Locking
N : Without Locking

O

Lever Directions

21,22 : Single 2ways
31,32,33,34 : 3ways
40 : Cross 4ways

Dimensions

Standard 
Lever Switch

Interlocking 
Lever Switch

Short
Lever Switch

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

F

Industrial & Hazardous Area Terminal Block 

General Technical Description

Control / Terminal Blocks

Environmental Protection

Product-related Environmental Protection
The health of our employees as well as the reduction of environmental impact through our products are in
the focus of SAMWHA

s accurate environmental management.

Rating The Clearance and Creepage Distances of Electrical Equipment 

The restriction of lead and five other potentially hazardous substances in electrical and electronic
equipment is specified by the EU-Directive 2002/95/EC.

The following substances used in electronic products are within the limits of the directive:

- Lead (Pb) of 1000ppm 
- Mercury (Hg)
- Cadmium (Cd)

- Hexavalent chrome (Cr (VI))
- Polybrominated biphenyl (PBB)
- Polybrominated diphenyl ehters (PBDE)

- Anticipated over-voltages 
- Used
- Measures to prevent soiling

RoHS

Clearance Distances

Clearance distances are rated in accordance 

with the following factors : 

Diagram showing clearance distance

Creepage Distance

- Intended 
- Used insulation materials

- Measures to prevent soiling

Clearance Distances

Creepage distances are rated in accordance with the  following factors : 

Diagram showing creepage distance

X

catalog_eng-html.html
background image

Groove are taken into account when measuring creepage distances if their minimum width X is rated
according to the following table :

If the corresponding clearance distance is less than 3mm, the smallest groove width may be reduced to 1/3
of this clearance distance.

Single Phase 3 or 2 Conductor AC or DC Networks

Rated Voltage

The rated voltage is derived from the rated voltage of the power supply and the corresponding network type.

Degree of soiling

Minimum width X in mm

1

2

3

4

0.25

1.0

1.5

2.5

Rated voltage of the power supply system

(network)

For insulation conductor-conductor(1)

All systems

For insulation conductor-earth

3-conductor systems, with mid-point earthing

V
12.5
24 / 25 / 30
42 / 48 / 50 / 60
30-60
100
110 / 120 / 150
220
110-220
120-240
300
220-440
600
480-960
1000

V

12.5

25, 32
50, 63

63

100

125, 600

250

250

320
500
630

1000
1000

V

-
-
-

32

-
-
-

125

-

250

-

500

-

Three Phase 4 or 3 Conductor AC Networks

Rated voltage of the power
supply system (network)

For insulation conductor-conductor(1)

All systems

For insulation conductor-earth

Three –phase 4-conductor systems

with earthed neutral

Three –phase 3-conductor system :

unearthed or earthed conductor

V
60
110/120/127
150
208
220 / 230 / 240
300
380 / 400 / 415  
440
480 / 500
575
600
660 / 690
720 / 830
960
1000

V

63

125
160
200
250
320
400
500
500
630
630
630
800

1000
1000

V

32
80

-

125
160

-

250
250
320
400

-

400
500
630

-

V

63

125
160
200
250
320
400
500
500
630
630
630
800

1000
1000

Controls / Termonal Blocks

F18_ F19

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

Industrial & Hazardous Area Terminal Block 

General Technical Description

Insulation Material Group

The insulation materials are divided into four groups depending on the comparative figures for creepage
distance (CTI : comparative tracking index) :

Converting AWG Conductors to 

This gives no indication of the actual conductor cross-sectional area. The relation-ship between AWG and

is shown in the following table.

The comparative tracking index is required to have been determined using special samples produced for
this purpose with test solution A in compliance with IEC 60112

Materials

Polyamide PA 

is one of the most frequently used technical plastics. The advantages of this material includes its 

very good electrical and mechanical properties, flexibility and resistance to breakage. In addition, its chemical 
structure gives PA good fire resistance even without the use of flame retardants.

Polybutylene Terephthalate PBT 

offers excellent dimensional stability and high continuous service temperature.

It has lower creepage current  resistance than other insulation materials.

Steel

parts whose function is to permanently maintain contact force are Zinc electroplated, with an additional 

chromate layer added to provide additional passivation.  Surface protection complies with the very highest 
standards. Results from laboratory tests are incorporated in producing the surface finish. Zinc still offers 
corrosion protection over a longer period of time even if the Zinc coating is partially damaged by scratches or 
pores. Zinc acquires a negative charge in relation to steel under the influence of an electrolytic fluid. The metal 
ions in the Zinc migrate to the steel giving the base material lasting protection against corrosive attack.

Conductive Materials

The current-carrying materials copper, brass and bronze are characterized by both high conductivity and good 
mechanical properties.

I

II

III a

III b

600

CTI

400

CTI

600

175

CTI

400

100

CTI

175

AWG

28

26

24

22

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

0.08

0.13

0.21

0.22

0.52

0.65

0.82

1.04

1.31

1.65

2.08

2.63

3.31

4.17

5.26

6.63

8.37

10.55

13.30

5

4

3

2

1

1/0

2/0

3/0

4/0

250

300

350

400

500

600

700

750

800

16.77

21.15

26.67

33.63

42.41

53.49

67.43

85.01

107

127

152

177

203

253

304

355

380

405

AWG

F

Control / Terminal Blocks

catalog_eng-html.html
background image

Ring Lug Type

The Ring Lug types is providing high mechanical retention and 

vibration resistance

Clamping Yoke Connection

Tension clamp system optically combines the specific properties

of steel and copper. Both the tension clamp and the clamping 
screw consist of hardened steel. This clamping yoke unit generates 
the necessary contact force. Connection of the conductor involves 
the tension clamp pressing the conductor against the bus-bar, 
which is made of copper or high quality brass. 

Connection Types

Terminal strips mounted from left to right

Closed side on the left, open side on the right

Open side of the terminal always closed using end plates or partition plates.

End brackets placed at the beginning and end of the terminal strip.

Mounting and End Brackets

TS32-DIN 46277-1 & EN 50035 G type RAIL

TS35-DIN 46277-3 & EN 50022 HAT type RAIL

Mounting Rail- All Aluminum Alloy

35

°

mounting angle

Mount hole size

Ø

7.0

Mount hole center 60mm

DIN rail fix bolt M6.0

DIN Rail Support-Zinc Plated Steel

Controls / Termonal Blocks

F20_ F21

TS32 C type

TS35 U type

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

SAMWHA Industrial & Hazardous Area Terminal Block

General Technical Description & Selection Table

CAT. NO

WIRE RANGE

AWG

SQ

FW

TQ 

]In.-

Lb

V

MATERIAL

FLAM-MA

BILITY

CERTIFICATE

CONNECTION TYPE

MOUNTING TYPE

A

UL

KOSHA 
(Ex e II)

Lug-

less

Bus
Bar

Lug

TS32

TS35

SCREW

Sectional

KEPIC

KHNP

SH-STB-1.2F

SH-STB-1.2FW

SH-STB-1.6T

SH-STB-1.6R

SH-STB-2.5C

SH-STB-2.5D

SH-STB-4C

SH-STB-4U

SH-STB-6C

SH-STB-6U

SH-STB-10C

SH-STB-16C

SH-STB-25C

SH-STB-50C

SH-STB-70C

SH-STB-20E-16CT

SH-STB-30E

SH-STB-150A

SH-STB-100B

SH-STB-200B

SH-STB-300B

SH-STB-400B

SH-STB-500B

SH-STB-600B

SH-STB-015L

SH-STB-015LD

SH-STB-015LT

SH-STB-025L

SH-STB-035L

SH-STB-065L

SH-STB-100L

10-18 SOL/STR

10-18 SOL/STR

12 STR

12 STR

12 STR

12 STR

12 STR

12 STR

10 STR

10 STR

16-8 STR

6

10-6

4 STR

2 STR

10

14-10

3-1

4-2

3-1

1/0-2/0 STR

3/0-4/0 STR

3/0-4/0 STR

3/0-4/0 STR

12 STR

12 STR

12 STR

10 STR

8 STR

6 STR

2 STR

6

6

4

4

2.5

2.5

4

4

6

6

10

16

25

50

70

6

6

-

38

80

125

200

250

325

4

4

4

6

10

16

35

2

2

2

4

2

4

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

4

2

2

2

2

2

10

10

12

12

12

12

12

12

12

12

15

15

20

75

75

15

15

120

150

100

195

195

195

195

10.6

10.6

10.6

22

88.5

220

220

500

380

600

500

600

600

600

600

750

600

600

750

600

600

750

600

600

600

600

600

600

600

600

600

600

600

600

600

600

600

600

15

20

16

16

20

20

20

27

36

36

40

65

55

95

125

20

30

95

95

145

180

250

250

250

15

15

15

25

35

65

110

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

PBT

PBT

PBT

PBT

PBT

PBT

PBT

PA6

PBT

PA6

PBT

PBT

PBT

PBT

PBT

PHENOL

PHENOL

PC/PHENOL

PC/PHENOL

PC/PHENOL

PC/PHENOL

PC/PHENOL

PC/PHENOL

PC/PHENOL

PA6

PA6

PA6

PA6

PA6

PA6

PA6

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

-

-

-

-

-

-

-

-

-

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

UL94-0

F

Control / Terminal Blocks

catalog_eng-html.html
background image

UL 1059 LISTED 

TS 32 – DIN 46227

-1 G TYPE RAIL 

Applications

Lug-Less Type

Lugless Terminal Block (Component)

SAMWHA terminal blocks are screw fixing type intended for application in control equipment and systems.

These terminal blocks are made up of individually molded units with electrical conductor.

Suitability for specific application depends upon the equipment specification in terms of creepage, clearance 

and breakdown voltage requirements, mounting and wire connectors used.

Cross-connections between terminals.

In complete jumpering units, common bar, sleeve and screw are supplied ready assembled to the required 

number of poles.

SH-STB-1.2F* type terminal block for use with Fuse, providing a circuit safety.

Body - Polybutylene Terephthalate PBT

Clamp - Steel

Current Bar - Copper

Steel - Electro Zinc Plated

Certificate

Dimensions & Weight

UL Listed NO. : XCFR2.E104831

TS32-DIN 46277-1 & EN 50035 G type RAIL

Clamping yoke type

UL 1059

CAT. NO.

DIMENSIONS

WEIGHT (KG/100)

WIDTH

HEIGHT

DEPT

EP

SH-STB-1.2F*

SH-STB-4C

SH-STB-10C

SH-STB-25C

SH-STB-50C

54.0

37.0

40.0

40.0

58.0

58.5
45.0
47.0
47.0
65.0

13.0

6.5

10.0

12.0

16.5

1.9

1.6

1.7

2.0

2.4

4.07

1.17

2.37

3.65

8.53

Technical Data

CAT. NO.

WIRE RANGE

MATERIAL FLAMMABILITY

AWG

SQ

WIRE

TYPE

FW

TQ 

(In.-Lb)

RATED

VOLTAGNT

RATED

CURRENT

SH-STB-1.2F*

SH-STB-4C

SH-STB-10C

SH-STB-25C

SH-STB-50C

10-18 SOL/STR
12 STR
16-8 STR
10-6
4 STR

6
4
10
25
50

2
2
2
2
2

10
12
15
20
75

AC500V
AC600V
AC600V
AC600V
AC600V

CU
CU
CU
CU
CU

15A
20A
40A
55A
95A

PBT
PBT
PBT
PBT
PBT

UL94-0
UL94-0
UL94-0
UL94-0
UL94-0

Note

: *

With Fuse

Terminal Blocks for Industry

Control / Terminal Blocks

Standard Materials

Finishes

Mounting Rail

Connection Type

Compliances / Approvals

Controls / Termonal Blocks

F22_ F23

SH-STB-4C, 10C, 
25C, 50C

SH-STB-1.2F

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

UL 1059

TS 32 – DIN 46227

-1 G TYPE RAIL 

Applications

Lug-LessType

Lugless  Terminal Block (Component)

SAMWHA terminal blocks are screw fixing type intended for application in control equipment and systems.

These terminal blocks are made up of individually molded units with electrical conductor.

Suitability for specific application depends upon the equipment specification in terms of creepage, clearance 

and breakdown voltage requirements, mounting and wire connectors used.

Cross-connections between terminals.

In complete jumpering units, common bar, sleeve and screw are supplied ready assembled to the required 

number of poles.

SH-STB-1.2FW* type terminal block for use with Fuse & LED indicator, providing a circuit safety & an error 

signal.

SH-STB-1.6R type is used with open barrel terminals and lug-less wires.

SH-STB-1.6T type is used with test block.

SH-STB-2.5D type is used with 4 forward wires.

Finishes

Body - Polybutylene Terephthalate PBT

Clamp - Steel

Current Bar - Copper

Steel - Electro Zinc Plated

Dimensions & Weight

Mounting Rail

Standard Materials

TS32-DIN 46277-1 & EN 50035 G type RAIL

Connection Type

Clamping yoke type

Compliances / Approvals

UL 1059

CAT. NO.

DIMENSIONS

WEIGHT (KG/100)

WIDTH

HEIGHT

DEPT

EP

SH-STB-1.2FW*

SH-STB-1.6T

SH-STB-1.6R

SH-STB-2.5C

SH-STB-2.5D

SH-STB-6C

SH-STB-16C

SH-STB-70C

54.0
43.0
58.0
28.0
51.5
41.0
42.0
74.0

58.5
70.5
44.5
38.5
56.0
49.5
49.5
76.0

13.0

8.3

6.7

6.5

7.1

7.1

9.8

21.7

1.9
1.9
1.6
1.6
1.8
1.8
1.7
3.8

4.26
2.29
1.55
0.78
1.74
1.60
2.47
18.2

Techinical Data

CAT. NO.

WIRE RANGE

MATERIAL FLAMMABILITY

AWG

SQ

WIRE

TYPE

FW

TQ 

(In.-Lb)

RATED

VOLTAGE

RATED

CURRENT

SH-STB-1.2FW*
SH-STB-1.6T
SH-STB-1.6R
SH-STB-2.5C
SH-STB-2.5D
SH-STB-6C
SH-STB-16C
SH-STB-70C

10-18 SOL/STR
12 STR
12 STR
12 STR
12 STR
10 STR
6
2 STR

6
4
4
2.5
2.5
6
16
70

2
2
4
2
4
2
2
2

10
12
12
12
12
12
15
75

380
600
500
600
600
750
750
750

CU
CU
CU
CU
CU
CU
CU
CU

20
16
16
20
20
36
65
125

PBT
PBT
PBT
PBT
PBT
PBT
PBT
PBT

UL94-0
UL94-0
UL94-0
UL94-0
UL94-0
UL94-0
UL94-0
UL94-0

Note

: *

With Fuse & LED Indicator

F

Terminal Blocks for Industry

Control / Terminal Blocks

SH-STB-2.5C 6C, 16C

SH-STB-2.5D

SH-STB-1.2FW

SH-STB-1.6T

SH-STB-1.6R

SH-STB-70C

catalog_eng-html.html
background image

Controls / Termonal Blocks

F24_ F25

SH-STB-025L, 

035L, 065L, 110L

SH-STB-015LT

SH-STB-015LT

KS C 2625 1990

TS 32 – DIN 46227

-1 G TYPE RAIL 

Applications

Ring Lug Type  

Ring Lug Terminal Block (Component)

SAMWHA terminal blocks are screw fixing type intended for application in control equipment and systems.

These terminal blocks are made up of individually molded units with electrical conductor.

Suitability for specific application depends upon the equipment specification in terms of creepage, 

clearance and breakdown voltage requirements, mounting and wire connectors used.

Cross-connections between terminals.

In complete jumpering units, common bar, sleeve and screw are supplied ready assembled to the required 

number of poles.

SH-STB-015LT type is used with test block.

SH-STB-015LD type is used with 4 forward wires.

Finishes

Body - Polyamide PA6

Current Bar - Copper

Steel - Electro Zinc Plated

Dimensions & Weight

Mounting Rail

Standard Materials

TS32-DIN 46277-1 & EN 50035 G type RAIL

Connection Type

Clamping yoke type

Compliances / Approvals

KS C 2625 1990

CAT. NO.

DIMENSIONS

WEIGHT (KG/100)

WIDTH

HEIGHT

DEPT

EP

SH-STB-015LD

SH-STB-015LT

SH-STB-015L*

SH-STB-025L

SH-STB-035L

SH-STB-065L

SH-STB-100L

70.0
43.0
39.0
42.0
45.5
53.0
64.0

60.0
61.0
37.0
38.5
42.0
51.0
56.0

8.9
8.9
8.9
10.9
11.7
14.6
19.5

1.4
1.2
1.1
1.2
1.3
1.6
1.8

2.30
1.40
1.0
1.40
1.71
3.30
3.32

Technical Data

CAT. NO.

WIRE RANGE

MATERIAL

FLAM-

MABILIT

AWG

SQ

WIRE

TYPE

FW

TQ 

(In.-Lb)

RATED

VOLTAGE

RATED

CURRENT

LUG SIZE

O.D-I.D

SH-STB-015LD

SH-STB-015LT

SH-STB-015L*

SH-STB-025L

SH-STB-035L

SH-STB-065L

SH-STB-100L

12 STR
12 STR
12 STR
10 STR
8 STR
6 STR
2 STR

4
4
4
6
10
16
35

4
2
4
2
2
2
2

10.6
10.6
10.6
22
88.5
220
220

600
600
600
600
600
600
600

CU
CU
CU
CU
CU
CU
CU

15
15
15
25
35
65
110

PA6
PA6
PA6
PA6
PA6
PA6
PA6

UL94-0
UL94-0
UL94-0
UL94-0
UL94-0
UL94-0
UL94-0

Max7.2-Min3.5
Max7.2-Min3.5
Max7.2-Min3.5
Max9.0-Min4.0
Max9.8-Min4.5
Max12.5-Min6.0
Max16.5-Min7.0

Note

:

*

For Hazardous Area Terminal Block See to (Page No  F30.)

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

10
14-10

8
8

2
2

15
15

600
600

CU
CU

20
30

PHENOL
PHENOL

F

Terminal Blocks for Industry

Control / Terminal Blocks

KS C 2625 1990 

KEPIC-EN 
Class 1E  

KHNP Certificate 

(Korea Hydro & 
Nuclear Power)

Applications

Ring Lug Section Type 

Nuclear Class 1E Ring Lug Sectional Terminal Block (Component)

SAMWHA terminal blocks are screw fixing type intended for application in control equipment and systems.

These terminal blocks are made up of individually molded units with electrical conductor.

Suitability for specific application depends upon the equipment specification in terms of creepage, 

clearance and breakdown voltage requirements, mounting and wire connectors used.

Cross-connections between terminals.

In complete jumpering units, common bar, sleeve and screw are supplied ready assembled to the required 

number of poles. 

Qualified through EQ test.

Finishes

Body - Phenolic resin

Current Bar - Copper

Steel - Electro Zinc plated

Mounting Type

Screw surface mounting

Dimensions & Weight

Compliances / Approvals

Standard Materials

KS C 2625 1990

KEPIC-EN Class-1E Terminal Block

END 1100, END 2000, END 3830

Connection Type

Ring lug type

Certificates

KEPIC-EN Certi. No. : EN-335

KHNP (Korea Hydro & Nuclear Power Co., Ltd.
Certi. No. : SP-2009-006

CAT. NO.

DIMENSIONS

WEIGHT (KG/100)

LENGTH

HEIGHT

BETWEEN MOUNTING HOLE

SH-STB-20E-16CT

SH-STB-30E-3

SH-STB-30E-6

SH-STB-30E-10

SH-STB-30E-12

120.0
70.0
120.0
186.0
218.5

41.0

35.5

35.5

35.5

35.5

109.5

59.0

109.0

175.0

208.5

24.13

12.14

21.25

32.72

37.65

Technical Data

CAT. NO.

WIRE RANGE

MATERIAL

AWG

SQ

WIRE

TYPE

FW

TQ 

(In.-Lb)

RATED

VOLTAGE

RATED

CURRENT

SH-STB-20E-16CT

SH-STB-30E-3,6,10,12

Sectional Construction

SH-STB-30E 

SH-STB-30E 

catalog_eng-html.html
background image

Controls / Termonal Blocks

F26_ F27

UL 1059 LISTED 

KEPIC-EN
Class 1E  

KHNP Certificate 

(Korea Hydro & 
Nuclear Power)

Applications

Bus Bar Section Type  

Nuclear Class 1E Bus  Bar Terminal Block (Component)

SAMWHA terminal blocks are screw fixing type intended for application in control equipment and systems.

These terminal blocks are made up of individually molded units with electrical conductor.

Suitability for specific application depends upon the equipment specification in terms of creepage, clearance 

and breakdown voltage requirements, mounting and wire connectors used.

Cross-connections between terminals.

In complete jumpering units, common bar, sleeve and screw are supplied ready assembled to the required 
number of poles.

Qualified through EQ test.

Finishes

Body - Phenolic resin or Polycarbonate

Current Bar - Copper

Steel - Electro Zinc plated

Mounting Type

Screw surface mounting

Compliances / Approvals

Standard Materials

UL 1059

KEPIC-EN Class-1E Terminal Block

END 1100, END 2000, END 3830

Connection Type

Bus bar type

Certificates

UL Listed NO. : XCFR2.E104831

KEPIC-EN Certi. No. : EN-335 

KHNP (Korea Hydro & Nuclear Power Co., Ltd. 
Certi. No. : SP-2009-006

CAT. NO.

BUS BAR

BUS BAR

FIXED POINT

W

T

BOLT

SH-STB-150A

SH-STB-100B

SH-STB-200B

SH-STB-300B

SH-STB-400B

SH-STB-500B

SH-STB-600B

30
30
30
30
40
50
50

3
3
4
5
4
5
6

M10
M10
M12
M18
M16
M16
M16

1
1
1
1
1
1
1

Dimensions 

CAT. NO.

BODY DIMENSIONS

BETWEEN MOUNTING

HOLE (1 pole)

LENGTH

WIDTH

HEIGHT

SH-STB-150A

SH-STB-100B

SH-STB-200B

SH-STB-300B

SH-STB-400B

SH-STB-500B

SH-STB-600B

46.2
46.2
46.2
46.2
62.4
62.4
62.4

40
40
40
40
40
40
40

48
48
48
48
48
48
48

62
62
62
62
75.8
75.8
75.8

SH-STB-025L, 

035L, 065L, 110L

SH-STB-105A,

100B~600B

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

Technical Data

CAT. NO.

WIRE RANGE

MATERIAL

WEIGHT

(KG/100)

AWG

SQ

WIRE

TYPE

FW

TQ 

(In.-Lb)

RATED

VOLTAGE

RATED

CURRENT

SH-STB-150A

SH-STB-100B

SH-STB-200B

SH-STB-300B

SH-STB-400B

SH-STB-500B

SH-STB-600B

3-1
4-2
3-1
1/0-2/0 STR
3/0-4/0 STR
3/0-4/0 STR
3/0-4/0 STR

-
38
80
125
200
250
325

4
2
2
2
2
2
2

120
150
100
195
195
195
195

600
600
600
600
600
600
600

CU
CU
CU
CU
CU
CU
CU

95
95
145
180
250
250
250

PC/PHENOL
PC/PHENOL
PC/PHENOL
PC/PHENOL
PC/PHENOL
PC/PHENOL
PC/PHENOL

18.80
18.80
24.85
32.12
55.35
64.25
73.18

Construction & Installation

NO.

Part Name

1
2
3
4
5
6
7

Body
End Plate
Bus Bar
Bolt Clamp
Marking Tag
Safety Plate
Fixed Base

Safety Cover
Bolt
Nut
Washer
S. Washer
Spring Pin
Support Screw

NO.

Part Name

8
9

10
11
12
13
14

F

Terminal Blocks for Industry

Control / Terminal Blocks

Bus Bar Section Type  

Nuclear Class 1E Bus  Bar Terminal Block (Component)

catalog_eng-html.html
background image

Terminal Blocks for Hazardous Area

Control / Terminal Blocks

Controls / Termonal Blocks

F28_ F29

UL 1059 

TS 32–DIN 46227-1 

G TYPE RAIL

TS 35-DIN 46277-3 

HAT Type RAIL

KOSHA Certificate 

(Korea Occupational 
Safety & Health 
Agency)

Applications

Lugless Increased Safety Ex e II Type  

Terminal Block (Component)

SAMWHA terminal blocks are screw fixing type intended for application in control equipment and systems.

These terminal blocks are made up of individually molded units with electrical conductor.

Suitability for specific application depends upon the equipment specification in terms of creepage, clearance 

and breakdown voltage requirements, mounting and wire connectors used.

Cross-connections between terminals.

In complete jumpering units, common bar, sleeve and screw are supplied ready assembled to the required 
number of poles.

Finishes

Body - Polyamide PA6

Clamp - Steel

Steel - Electro Zinc plated

Mounting Rail

TS32-DIN 46277-1 & EN 50035 G type RAIL

TS35-DIN 46277-3 & EN 50022 HAT type RAIL

Compliances / Approvals

Standard Materials

UL 1059

IEC 60079-0  Equipment - General requirements

IEC 60079-7 Equipment protection by increased safety “e”

Connection Type

Clamping yoke type

Certificate

Certified KOSHA (Korea Occupational Safety & Health 
Agency) : 10-AV2BO-0003U & 4U

Dimensions & Weight

CAT. NO.

DIMENSIONS

WEIGHT (KG/100)

WIDTH

HEIGHT

DEPT

EP

SH-STB-4U

SH-STB-6U

41.5
42

42.0
42

1.6
1.6

7.0
7.0

1.0
1.1

Technical Data

CAT. NO.

WIRE RANGE

MATERIAL

FLAMMABILIT

AWG

SQ

WIRE

TYPE

FW

TQ 

(In.-Lb)

RATED

VOLTAGE

RATED

CURRENT

SH-STB-4U

SH-STB-6U

12 STR
12 STR

4
6

2
2

12
12

600
600

CU
CU

27
36

PA6
PA6

UL94-0
UL94-0

SH-STB-4U, 6U

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

KS C 2625 1990 

KOSHA Certificate 

(Korea Occupational 
Safety & Health 
Agency)

Applications

Ring Lug  Increased Safety Ex e II Type

Terminal Block (Component)

SAMWHA terminal blocks are screw fixing type intended for application in control equipment and systems.

These terminal blocks are made up of individually molded units with electrical conductor.

Suitability for specific application depends upon the equipment specification in terms of creepage, clearance 

and breakdown voltage requirements, mounting and wire connectors used.

Cross-connections between terminals.

In complete jumpering units, common bar, sleeve and screw are supplied ready assembled to the required 
number of poles.

Finishes

Body - Polyamide PA6

Current Bar - Copper

Steel - Electro Zinc plated

Mounting Type

Screw surface mounting

Compliances / Approvals

Standard Materials

KS C 2625 1990

IEC 60079-0  Equipment - General requirements

IEC 60079-7 Equipment protection by increased safety “e”

Connection Type

Ring lug type

Certificate

Certified KOSHA (Korea Occupational Safety & Health 

Agency) : 10-AV2BO-0002U

Dimensions & Weight

CAT. NO.

DIMENSIONS

WEIGHT (KG/100)

WIDTH

HEIGHT

DEPT

EP

SH-STB-015L

39.0

37.0

1.1

8.9

1.0

Technical Data

CAT. NO.

WIRE RANGE

MATERIAL

UG SIZE

O.D-I.D

FLAM-

MABILIT

AWG

SQ

WIRE

TYPE

FW

TQ 

(In.-Lb)

RATED

VOLTAGE

RATED

CURRENT

SH-STB-015L

12 STR

4

4

10.6

600

15

CU

PA6

Max7.2-Min3.5

UL94-0

F

Terminal Blocks for Hazardous Area

Control / Terminal Blocks

SH-STB-015L

catalog_eng-html.html
background image

Controls / Termonal Blocks

F30_ F31

ESL

CAT. NO.

DIMENSIONS

COLOR

WEIGHT (KG/100)

WIDTH

HEIGHT

ESS

ESL

35.0
44.5

8.6
15.8

Yellow or Black
Yellow or Black

0.62
0.78

EP is made Polybutylene terephthalate PBT or Polyamide PA6 which applies only to the Clip-on 
mounting terminal blocks. 

ESS & ESL are made Polyamide PA6 which applies only to the Clip-on mounting terminal blocks. 

ESS

TS 35

TS 32 & TS 35 are made Aluminum Alloy which applies only to the Clip-on mounting terminal blocks. 

TS 32

TS32-DIN 46277-1 & EN 50035 G type RAIL

TS35-DIN 46277-3 & EN 50022 HAT type RAIL

DIN Rail Support-Zinc Plated Steel

35

°

mounting angle

Mount hole size

Ø

7.0

Mount hole center 60mm

DIN rail fix bolt M6.0

End Plate 

EP End Plate

End Stopper  

ESS & ESL  End Stopper

Mounting Rail  

TS 32 & TS 35 Mounting Rail

Support Bracket 

Accessories

Control / Terminal Blocks

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

The SAMWHA marking tag card as an individual marking system consists of 5 strips with 10 tags per strip 
(50 tags per card.) RM5 tags with flexible feet and RM5 tags are made of a soft PVC which can be easily inserted
either before or after assembly of terminal blocks. Marking letters can be printed with numbers 0,1,2…100 etc, 
to 999. For self Marking, there is a marker pen which can be directly used on unprinted tags. Special marking
letters can be printed according to customer order.

Fixed base is made of BAKELITE which applies only to Bus-Bar type terminal blocks. Fixed base can be designed
according to customer order.

F

Accessories

Control / Terminal Blocks

Marking Tag  

RM5  Marking Tag

Fixed Base

catalog_eng-html.html
background image

Controls / Termonal Blocks

F32_ F33

MEMO

Control

s

Termonal Blocks

F

catalog_eng-html.html
background image

Efficiency and Safety, Electric Line and Equipment Protection

Manufactured by high technology and long-term experience, Samwha's power panels provide

efficiency and safety, as well as various control functions. Samwha always supply it’s quality products

that build long-last relationships with our customers. 

catalog_eng-html.html
background image

Smart  +  Technology  +  Human

G

G

Power/
Control Panels

Contents

SAMWHA Electrical

Power & Control Panels

Products

G2

catalog_eng-html.html
background image

Products

High Voltage Switchgrar (HVS)

SAMWHA's High Voltage Switchgear provides
centralized control and protection of high-voltage
power equipment and circuits in industrial,
commercial, and utility installations involving
generators, motors, feeder circuits, and
transmission and distribution lines. 

Medium Voltage Switchgear (MVS)

SAMWHA's Medium Voltage Switchgear provides
centralized control and protection of medium-
voltage power equipment and circuits in
industrial, commercial, and utility installations
involving generators, motors, feeder circuits, and
transmission and distribution lines. 

Power & Control Panels

SAMWHA Electrical

G

HVS (High Voltage Switchgear)        

LBS (Line Breaker Switch) & 
LA (Lightning Arrester)

MOF(Metering out fit)

PT (Voltage transformer)
& PF (Power Fuse)

VCB 
(Vaccum circuit breaker)

catalog_eng-html.html
background image

Samwha Electrical

G

Samwha Electrical

G2 _ G3

Low Voltage Switchgear(LVS)

SAMWHA's low voltage switchgear provides
centralized control and protection of low voltage
power equipment and circuits in industrial,
commercial, and utility installations involving
generators, motors, feeder circuits, and
transmission and distribution lines. 

Transformer Switchgear (TRS)

We offer a wide range of Power Transformers, 
which is used in various industries for distribution 
and transmission. 

LVS (Low Voltage Switchgear)  

RB (Rectifier & Battery) 

ACB & Tie ACB
(Air circuit Breaker)  

ACB & MCCB 
(Mold cased circuit breaker) 

ATS(Auto transfer switch) &
MCCB

catalog_eng-html.html
background image

Products

Power & Control Panels

SAMWHA Electrical

G

Motor Control Centers(MCC)

SAMWHA's motor control centers offer the best method 
for grouping motor control, associated control, distribution
equipment and industrial communications. They are
specially designed to operate machinery, industrial
processes, and commercial building systems.

Plc Control Panels (PCP)

PLC Control panels are used for sequential relay control,
motion control, process control, distributed control systems
and networking. This offer data handling and storage and
processing power and communication capabilities.

Power Distribution Centers (PDC)

SAMWHA provides top quality rack-mounted and floor-
based power distribution products. Features offer space
savings, cost savings, and the ultimate in customization to
meet a wide variety of applications and environments.

Local Control Panels (LCP)

Local control panels help to perform a temporary and local
action on electrical and temperature installations of a room.
Their action is generally applied to heating / ventilation and
lighting devices but several other functions are possible.

catalog_eng-html.html
background image

Samwha Electrical

G

Samwha Electrical

G4 _ G5

Invertor Control Panels (ICP)

SAMWHA’s Invertor control panels are engineered to offer tight control over both torque and speed regulation,
while offering the industry's simplest and most user-friendly operator interface. Designed to handle the industry's
most demanding conditions, our drives and panels deliver only the highest level of performance.

ONE HOUSING CUSTOM 
BUILD PANELS

PC CIRCUIT BREAKER BOXES

PC CONTROL BOXES

Welding Receptacles Panel

SAMWHA’s Welding receptacles panels offer the best
method and cost of control. Also most user-friendly 
operator interface.

Motor Control Panels (MCP)

SAMWHA's motor control panels offer individual motor control.
They are specially designed to operate machinery, industrial
processes, and commercial building systems.

Lighting Distribution Panels (LDP)

SAMWHA's lighting distribution panels offer the best method
for grouping lighting fixture line control, distribution
equipment and industrial communi-cations. They are
specially designed to operate machinery, industrial
processes, and commercial building systems.

catalog_eng-html.html
background image

Combustion Principles

A flammable liquid, vapor or combustible dust 

must be present in sufficient quantity

The flammable liquid, vapor or combustible dust 

must be mixed with air or oxygen in the 
proportions required to produce an explosive mixture

A source of energy must be applied to the 

explosive mixture

The Oxygen Side

There must be a supply of oxygen present. In most situations this is applicable as a result of the oxygen 

content in the air (21%)

There must be sufficient fuel present in the air to form an ignitable mixture. The fuel may be in the form 

of a gas, vapor, mist or dust

There must be a source of ignition with sufficient energy to ignite the fuel-air mixture. For electrical 
equipment this may be from an arcing or sparking device or from a hot surface.

Explosion Proof Technical

Explosion Protection

Three basic conditions must be satisfied for a fire or
explosion to occur:

The Hazard Triangle

For an area to be classified as a Hazardous
Location there must be the possibility that the
conditions for an explosion or fire may exist as the
result of some abnormal occurrence. To better
understand what these conditions may be, an
understanding of the combustion triangle is a
fundamental requirement.

There may be sources of ignition other than electrical equipment, such as hot exhaust surfaces from
internal combustion engines. These devices do not fall within the scope of the North American electrical
codes and are normally covered by other codes and standards such as Occupational Health and Safety

In most situations there is sufficient oxygen present in the air (21%) to meet the conditions for an explosion. 

In some situations however, oxygen may be excluded by blanketing an enclosed area with another gas to
ensure there will not be sufficient oxygen present. 
The blanket gas is normally an insert gas, such as nitrogen, or in some cases it may even be a flammable
gas such as methane.

The basic approach to design in a Hazardous Location is to ensure that all three sides of the triangle do not
exist simultaneously. If any one side of the triangle is not present, an explosion cannot occur. 
Protection against explosions will therefore require control or elimination of one or more sides of the
triangle.

For an explosion to take place, all three sides of the
triangle, satisfying the following conditions, must
be present:

In applying these principles, the quantity of the
flammable liquid or vapor that may be liberated and
its physical characteristics must be recognized.

Vapors from flammable liquids also have a natural
tendency to disperse into the atmosphere, and
rapidly become diluted to concentrations below the
lower flammable limit, particularly when there is
natural or mechanical ventilation.

The possibility that the gas concentration may be
above the upper flammable limit does not afford
any degree of safety, as the concentration must
first pass through the flammable range to reach
the upper flammable limit.

Fuel

lgnition Source

All three elements must be present for an explosion to occur

Oxygen

Appendix

catalog_eng-html.html
background image

Appendix

1 _ 2

Ignition Sources - Gases & Vapors

Ignition sources can occur by various mechanical means, but for the purpose of this publication we
consider only electrical sources of potential ignition.
The most important characteristics of flammable substances in regard to ignition are:

The Fuel Side

If avoiding the use of flammable substances is not possible, the fuel side of the triangle is removed by
enclosing the gas or dust in piping, or vessels in the case of gas, vapors or flammable liquids, or in
enclosed ducts in the case of dust. 

Of course there is always the possibility that flammable materials could be released in sufficient quantity to
form an explosive mixture as a result of a malfunction of equipment. In some situations an explosive
mixture may be present frequently or continuously as a result of normal operations such as the interior of
vented fuel storage tanks or the interior of paint spray booths.
The determination of the amount of time that an explosive mixture will be present in an area is the basis of
“area classification”

The Ignition Side

Upper Flammable Limit

Lower Flammable Limit

Flash Point of the flammable material

Auto-Ignition Temperature

Vapor Density

The electrical equipment installed in Hazardous Locations forms the ignition side of the triangle. 
The various designs used for electrical equipment ensure there will not be a simultaneous occurrence of
all three sides of the triangle. The specific design of an electrical device for use in a Hazardous Location
will depend on the amount of time it will be exposed to flammable concentrations of flammable material.
In other words, the design must be suitable for the classification of the area in which it is installed.

Overall the design of equipment for the different “Zones” or “Divisions” is based on ensuring the probability
of the simultaneous occurrence of a flammable gas (or vapor, mist or dust) concentration and an ignition
source from equipment is so low that in practice it does not happen. It has been suggested in a number of
industry papers that the probability of an ignition occurring once every hundred years is so low that in
practice it will not happen. 

Upper & Lower Flammable Limits

There are a number of characteristics of gases and vapors that are important for the classification of a
Hazardous Location and the application of equipment within the Hazardous Location.

is the lowest percentage by volume of gas (or vapor)
in a gas-air mixture that will form an ignitable
concentration. Below that concentration there is
insufficient gas or vapor in the mixture and the gas-
air mixture is too lean to be ignited

Lower Explosive Limit (LEL)

Upper Explosive Limit (UEL)

is the highest percentage by volume of gas or vapor
in a gas-air mixture that will form an ignitable
concentration. Above that concentration there is too
much gas or vapor in the mixture and the gas-air
mixture is too rich to ignite.

Probabilities at this level (approximately 1 in 1,000,000) are similar to those done for the catastrophic
failure of piping or vessels.

UEL - Upper Explosive Limit
LEL - Lower Explosive Limit

LEL

UEL

No  Risk of lgnition

No  Risk of lgnition

Gas Volume
% age

Risk of
lgnition

Appendix

catalog_eng-html.html
background image

Upper & Lower Flammable Limits

If the percentage of gas is below the lower limit, the mixture is too lean (insufficient fuel) to ignite. The
mixture is too rich (insufficient oxygen) if the percentage is above the upper limit.
Some gases, such as methane, are ignitable over a relatively narrow range of 5% to 15%. Methane is
frequently used in the form of natural gas to provide a low-pressure gas blanket over liquid in a tank to
ensure an ignitable mixture is not formed. 

Flash Point of The Flammable Materials Auto Ignition Temperature
Vapor Density

The presence of the natural gas blanket ensures the mixture in the tank will always be above the UEL.
Other gases are ignitable over a relatively large range, such as acetylene (2.5 to 100%) and hydrogen, which
is ignitable from 4% to 75%. As hydrogen is a very light gas, it is often used in large turbine generators to
reduce the friction loss of the rotor.
Because of the extremely large explosive range of hydrogen, great care must be taken to ensure
concentrations within the generator do not enter the explosive range as the result of the introduction of air.
Refer to Appendix I NFPA 325 M-1991, Fire Hazard Properties of Flammable Liquids, Gases & Volatile
Solids, for the complete listing of gases and vapors.

Class I atmospheric hazards are divided not only into the four groups, A, B, C, and D shown in Appendix I,
but also into two divisions.
Division 1 covers locations where flammable gases or vapors may exist under normal operating conditions,
under frequent repair or maintenance operations, or where breakdown or faulty operation of process
equipment might also cause simultaneous failure of electrical equipment.
Division 2 covers locations where flammable gases, vapors or volatile liquids are handled either in a closed
system, or confined within suitable enclosures, or where hazardous concentrations are normally
prevented by positive mechanical ventilation. 
Areas adjacent to Division 1 locations, into which gases might occasionally flow, would also be Division2.

is shown in table 1.6

Classification of Hazardous Atmospheres Selected from NEC 2008

Class I Atmospheric Hazards

Class III atmospheric hazards cover locations where combustible Fibers / flyings are present but not likely
to be in suspension in air in quantities sufficient to produce ignitable mixtures. 
Division 1 is where they are manufactured and Division 2 is where they are stored.

Class II atmospheric hazards cover three groups of combustible dusts, summarized in Appendix II. 
The groups are based on the type of material : Group E metallic, Group F carbonaceous, or Group G
organic. 
Whether an area is Division 1 or 2 depends on the quantity of dust present, except that for Group E there is
only Division 1.

Class II Atmospheric Hazards

Class III Atmospheric Hazards

GAS
(% by Volume)

Lower Flammable Limit

Upper Flammable Limit

The mixture of gas and air must be between the Upper and Lower Flammable Limits for a fire or explosion to occur.

IGNITON
(Spark, Hot Surface,
Exothermic)

Explosion Proof Technical

Explosion Protection

Appendix

catalog_eng-html.html
background image

Appendix

3 _ 4

Comparison Between Divisions & Zones Comparison of Protection Between 
NEC Article 500 & NEC Article 505

A comparison of the Division and Zone classification system is shown in Table 3.1. Division 2 is equivalent to
Zone 2 while Division 1 is either Zone 0 or 1. Zone 0 is reserved for those areas continuously hazardous
(e.g., inside a vented fuel tank), so other Division 1 areas would be classified as Zone 1.

Evaluation of Hazardous Areas

is shown in table 1.7 & 1.10

Each area that contains gases or dusts that are considered hazardous must be carefully evaluated to make
certain the correct electrical equipment is selected. 

Many hazardous atmospheres are Class I, Group D, or Class II, Group G. 
However, certain areas may involve other groups, particularly Class I, Groups B and C. 

NEC 501

NEC 502

NEC 503

NEC 504

NEC 505

the requirements for electrical and electronic equipment and wiring for all voltages in 

Class I, Division

1 and 2

locations where fire or explosion hazards may exist due to 

flammable gases or vapors or

flammable liquids.

the requirements for electrical and electronic equipment and wiring for all voltages in 

Class II, Division

1 and 2

locations where fire or explosion hazards may exist due to 

combustible dust.

the requirements for electrical and electronic equipment and wiring for all voltages in 

Class III, Division

1 and 2

locations where fire or explosion hazards may exist due to 

ignitable fibers/flyings.

the installation of 

intrinsically safe (I.S.) apparatus,

wiring, and systems for 

Class I, II, and III

locations.

the requirements for the zone classification system as an alternative to the division classification
system covered in Article 500 for electrical and electronic equipment and wiring for all voltages in
Class I, Zone 0, Zone 1, and Zone 2 hazardous (classified) locations where fire or explosion hazards
may exist due to flammable gases, vapors, or liquids.

Equipment Temperature Classification

The marking shall specify the temperature class or operating temperature at a 40°C ambient temperature,
or at the higher ambient temperature if the equipment is rated and marked for an ambient temperature of
greater than 40°C.
The temperature class, if provided, shall be indicated using the temperature class (T Codes) shown in
Table . Equipment for Class I and Class II shall be marked with the maximum safe operating temperature,
as determined by simultaneous exposure to the combinations of Class I and Class II conditions.

Classification of Maximum Surface Temperature

Temp. (

)

Temp. (

)

IEC /EN NEC 505-10

JIS

NEC 500.3

CEC 18-052

300~450
280~300
260~280
230~260
215~230
200~215
180~200
165~180
160~165
135~160
120~135
100~120
85  ~100

~85

572~842
536~572
500~536
446~500
419~446
392~419
356~392
329~356
320~329
275~320
248~275
212~248
185~212

~185

T1

T2

T3

T4

T5
T6

G1

G2

G3

G4

G5

T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

About NEC Scope 

Appendix

catalog_eng-html.html
background image

Method of Protection

The definition of Explosion Protection is electrical apparatus designed with specific safety measures to
prevent ignition of a surrounding gas or vapor during normal operation.  An explosion-protected device will
not create an internal, or transmit an external ignition source, either by spark, or hot surfaces.
Types of protection is shown Table 1.8~9

This concept allows for consideration of risk (ie consequences of an explosion) as opposed to just the
probability of a flammable atmosphere existing-the conventional selection criteria between the types of
protection and the zone of use

Copper-Free Aluminum

Copper-free aluminum is particularly resistant to salt atmospheres, sulfur gases, and ammonium nitrate.
SAMWHA copper-free aluminum alloy contains a maximum of 4/10 of 1% copper. Above this level, the rate
of corrosion due to galvanic action within the structure of the metal increases rapidly. SAMWHA copper-
free aluminum products provide optimum protection against galvanic corrosion. 

is shown in table 1.11

Condition of Hazardous Area

is shown in table 1.12 & 1.13

Equipment Protection Levels – EPL

Enclosures are designed to protect components mounted inside from the outside environment. When
these enclosures contain electrical equipment, the degree of protection is critical to shield the components
from moisture and dusts that could contaminate and damage the equipment. The North American
Electrical Manufacturers Association (NEMA) have designated numbers to describe the protection that the
enclosure will render. Likewise the IEC Standard IEC 60529 provides a means of classifying the degree of
protection from touch, dust, water and impact.

The IEC designation of the ratings is known as Ingress
Protection or IP. The IP classification should not be construed as indicating corrosion resistance. The IP is
followed by 2 numbers with the first number providing the degree of protection against solid objects and
dust, and the second number the degree of protection against water.  
IP Grade is shown in Table 1.14
NEMA vs IP Ratings are shown in table 1.15
COMPARISION ENCLOSURE BETWEEN NEC CODE  & NEMA CODE is shown in table 1.16

NEMA vs IP Ratings

When designing a new facility or improving an old one, corrosion control can mean the difference between
trouble-free operation and costly downtime. At SAMWHA, our years of experience in corrosion control can
help you reduce equipment failures, costly repairs and loss of production. The general guide below can
help you in selecting the most suitable material for products used in corrosive environments.
General Guide for Product Material Selection is shown in Table 1.17

Cast  Iron

Cast iron generally resists corrosion from alkalies, organic compounds, neutral and slightly acidic
solutions, and certain concentrated acids and neutral brines. Cast Iron products are normally supplied with
a finish of electrogalvanized zinc plate covered with an aluminum acrylic paint or Zinc Hot dip galvanized. 

Brass

This metal was developed for structural and engineering uses requiring metals with high strength and
fabrication capabilities, along with a corrosion resistance equal to that of copper. Brass is resistant to most
dry gases and has excellent marine, industrial and rural atmospheric corrosion resistance. With variations
of temper and chemical composition, a variety of nonmagnetic, high strength, readily fabricated Brass can
be achieved. 

Combating Corrosion

Here are capsule descriptions of the standard materials available in the comprehensive SAMWHA product
line. 

SAMWHA Corrosion-Resistant Materials

Explosion Proof Technical

Explosion Protection

Appendix

catalog_eng-html.html
background image

Appendix

5 _ 6

Stainless Steel

Mounting hardware, hinges and cover bolts on most SAMWHA enclosures and lighting fixtures are made of
300 Series stainless steel, one of the highest grades of stainless steel offering strong, durable components
that have excellent corrosion resistance to most chemicals and vapors. Stainless steel cover bolts and
hinges reduce hassles that can be caused by corroding steel hardware when accessing enclosures for
routine maintenance, offering labor savings to the end user. 

Neoprene

A major industry workhorse. Neoprene is classified as a moderately oil-resistant rubber, with very good
weather/ozone resistance, along with good resistance to oxidative chemicals. Neoprene has inherent high
tensile strength, elongation and wear properties, at pure gum levels. Due to its excellent flame resistance
and self extinguishing characteristics, it is a must in areas where fire is a potential hazard. Neoprene is
used for gaskets, o-rings, bushings and boots on a variety of products.  

Other

In addition to the selection of the enclosure or housing materials best suited for use in a specific corrosive
environment, careful attention should also be given to such components as cover fastening bolts, operating
shafts, etc. For the classic weakest link reasons, these should be of a suitable material and of a physical
configuration compatible with the intended installation and operation. 

For example: should the corrosive environment involve chemicals that tend to accumulate on operating
mechanisms (such as pushbuttons, operating shafts, etc.), a design should be selected that shields the
mechanism as best possible, or one that would positively overcome any build-up when operated. 

Threaded operating mechanisms and cover openings require lubricants to inhibit corrosion and maintain
rain tightness. 

Use of O-ring gaskets on threaded covers and operating shafts can provide additional resistance to
corrosion of the threaded joints and interior of the device. 
Installation of breathers, drains or space heaters in enclosures can reduce or eliminate the corrosion of
interior components due to condensation build-up. A breather is installed in the top of an enclosure to
provide ventilation to minimize condensation in enclosures. 

Drains are used in humid atmospheres or in wet locations where it is likely that water can gain entrance to
the interiors of enclosures or raceways and are installed in the bottom of the enclosure. A space heater in
an enclosure with heat producing electrical components can eliminate the cycling of temperatures in an
enclosure that can draw in condensation. The space heater can maintain a positive internal pressure that
prevents condensation, reducing corrosion effects. 
Provides protection for a wide range of ferrous and non-ferrous metals including steel, copper, aluminum,
brass, solder, silver and others. 

Appendix

catalog_eng-html.html
background image

Acetaldehyde
Acetic Acid
Acetic Anhydride
Aceton
Acetone Cyanohydrin
Acetonitril
Acetylene
Acrolein (inhibited)1
Acrylic Acid
Acrylonitrile
Adiponitrile
Allyl Alcohol
Allyl Chloride
Allyl Glycidyl Ether1
Ammonia2
n-Amyl Acetate
sec-Amyl Acetate
Aniline
Benzene
Benzyl Chloride
1,3-Butadiene1
Butane
1-Butanol
2-Butanol
n-Butyl Acetate
iso-Butyl Acetate
sec-Butyl Acetate
t-Butyl Acetate
n-Butyl Acrylate (inhibited)
n-Butyl Formal
n-Butyl Glycidyl Ether1
Butyl Mercaptan
t-Butyl Toluene
Butylamine
Butylene
n-Butyraldehyde
n-Butyric Acid
Carbon Disulfide
Carbon Monoxide
Chloroacetaldehyde
Chlorobenzene
1-Chloro-1-Nitropropane
Chloroprene
Cresol
Crotonaldehyde
Cumene
Cyclohexane
Cyclohexanol
Cyclohexanone
Cyclohexene
Cyclopropane
p-Cymene
n-Decaldehyde
n-Decanol
Decene
Diacetone Alcohol
o-Dichlorobenzene

Table 1.6  Flash Point of the Flammable Materials, Auto Ignition Temperature, Vapor Density

C
D
D
D
D
D
A

B(C)

D
D
D
C
D

B(C)

D
D
D
D
D
D

B(D)

D
D
D
D
D
D
D
D
C

B(C)

C
D
D
D
C
D
A
C
C
D
C
D
D
C
D
D
D
D
D
D
D
C
D
D
D
D

II A
II A

II A

II A
II C
II B

II B

II A

II A
II A

II A
II A

II B
II A
II A
II A

II C
II A

II A
II A

II B

347
867
600
869

1270

975
581
455
820
898

-

713
905

-

928
680

-

1139

928

1085

788
550
650
761
790
790

-
-

559

-
-
-
-

594
725
425
830
194

1128

-

1099

-
-

1038-1110

450
795
473
572
473
471
938
817

-

550
455

1118
1198

175
464
316
465
688
524
305
235
438
481

-

378
485

-

498
360

-

615
498
585
420
288
343
405
421
421

-
-

293

-
-
-
-

312
385
218
443

90

609

-

593

-
-

559-599

232
424
245
300
245
244
503
436

-

288
235
603
647

-38

103
120

-4

165

42

gas

-15

122

32

200

70

-25

-

gas

60
89

158

12

153
gas

-76

98
75
72

-

88

-

118

-
-

35

-

10

gas

-8

161

-22

gas

-

82

144

-4

178-187

55
96

-4

154
111

20

gas
117

-

180

131

148
151

-39

39
49

-20

74

6

gas

-26

50

0

93
21

-32

-

gas

16
32
70

-11

67

gas

-60

37
24
22

-

31

-

48

-
-

2

-

-12

gas

-22

72

-30

gas

-

28
62

-20

81-86

13
36

-20

68
44

-7

gas

47

-

82

55

64
66

4.0
4.0
2.7
2.5
2.2
3.0
2.5
2.8
2.4
3.0

-

2.5
2.9

-

15

1.1

-

1.3
1.3
1.1
2.0
1.6
1.4

1.7@212°F

1.7

-

1.7

-

1.5

-
-
-
-

1.7
1.6
1.9
2.0
1.3

12.5

-

1.3

-

4.0

1.1-1.4

2.1
0.9
1.3

-

1.1@212°F

-

2.4

0.7@212°F

-
-
-

1.8
2.2

60

19.9@200°F

10.3

13

12.0
16.0

100

31.0

8.0

17

-

18.0
11.1

-

28

7.5

-

11

7.9

-

12.0

8.4

11.2

9.8@212°F

7.6

-

9.8

-

9.9

-
-
-
-

9.8

10.0
12.5
10.0
50.0
74.0

-

9.6

-

20.0

-

15.5

6.5
8.0

-

9.4

-

10.4

5.6

-
-
-

6.9
9.2

1.5
2.1
3.5
2.0
2.9
1.4
0.9
1.9
2.5
1.8

-

2.0
2.6

-

0.6
4.5
4.5
3.2
2.8
4.4
1.9
2.0
2.6
2.6
4.0

-

4.0

-

4.4

-
-

3.1

-

2.5
1.9
2.5
3.0
2.6
1.0

-

3.9
4.3
3.0

-

2.4
4.1
2.9
3.5
3.4
2.8
1.5
4.6

-

5.5

4.84

4.0
5.1

NEC500

Class I*

Group

IEC

60079

Substance

Auto-Ignition

Temp.*

Flammable Limits** 

Percent by Volume

Flash Point**

Lower

Upper

Vapor

Density**

(Air Equals

1.0)

Explosion Proof Technical

Explosion Protection

Appendix

catalog_eng-html.html
background image

1,1-Dichloroethane
1,2-Dichloroethylene
1,1-Dichloro-1-Nitroethane
1,3-Dichloropropene
Dicyclopentadiene
Diethyl Benzene
Diethyl Ether
Diethylamine
Diethylaminoethanol
Diethylene Glycol Monobutyl Ether
Diethylene Glycol Monomethyl Ether
Di-isobutyl Ketone
Di-isobutylene
Di-isopropylamine
N-N-Dimethyl Aniline
Dimethyl Formamide
Dimethyl Sulfate
Dimethylamine
1,4-Dioxane
Dipentene
Di-n-propylamine
Dipropylene Glycol Methyl Ether
Dodecene
Epichlorohydrin
Ethane
Ethanol
Ethyl Acetate
Ethyl Acrylate (inhibited)
Ethyl sec-Amyl Ketone
Ethyl Benzene
Ethyl Butanol
Ethyl Butyl Ketone
Ethyl Chloride
Ethyl Formate
2-Ethyl Hexanol
2-Ethyl Hexyl Acrylate
Ethyl Mercaptan
n-Ethyl Morpholine
Ethyl nitrate
2-Ethyl-3-Propyl Acrolein
Ethyl Silicate
Ethylamine
Ethylene
Ethylene Chlorohydrin
Ethylene Dichloride
Ethylene Glycol Monobutyl Ether
Ethylene Glycol Mono-butyl Ether Acetate
Ethylene Glycol Monoethyl Ether
Ethylene Glycol Mono-ethyl Ether Acetate
Ethylene Glycol Monomethyl ether
Ethylene Oxide1
Ethylenediamine
Ethylenimine
2-Ethylhexaldehyde
Formaldehyde (Gas)
Formic Acid (90%)

Fuel and Combustible Process Gas (containing 
more than 30 percent H2 by volume)

D
D
C
D
C
D
C
C
C
C
C
D
D
C
C
D
D
C
C
D
C
C
D
C
D
D
D
D
D
D
D
D
D
D
D
D
C
C
A
C
D
D
C
D
D
C
C
C
C
D

B(C)

D
C
C
B
D

B

II B

II B

II A
II A
II A
II A

II C

II B

II B

II C

II B

820
860

-
-

937

743-842

320
594

-

442
465
745
736
600
700
833
370
752
356
458
570

-

491
772
882
685
800
702

-

810

-
-

966
851
448
485
572

-
-
-
-

725
842
797
775
460
645
455
715
545
804
725
608
375
795
813

-

438
460

-
-

503

395-450

160
312

-

228
241
396
391
316
371
455
188
400
180
237
299

-

255
411
472
363
427
372

-

432

-
-

519
455
231
252
300

-
-
-
-

385
450
425
413
238
340
235
379
285
429
385
320
191
429
434

-

22
36

168

95
90

133-135

-49

-9

-

172
205
120

23
30

145
136
182
gas

54

113

63

186

-

88

gas

55
24
50

-

70

-

115

-58

-4

164
180

0

-
-

155
125

0

gas
140

56

143
160
110
124
102

-20

104

12

112
gas
122

-

-6

2

76
35
32

56-57

-45
-23

-

78
96
49

-5
-1

63
58
83

gas

12
45
17
86

-

31

gas

13

-4

10

-

21

-

46

-50
-20

73
82

-18

-
-

68
52

-18

gas

60
13
62
71
43
52
39

-28

40

-11

44

gas

50

-

5.6
5.6

-

5.3

-
-

1.9
1.8

-

0.85

-

0.8@200°F

0.8
1.1

-

2.2@212°F

-

2.8
2.0

0.7@302°F

-
-
-

3.8
3.0
3.3
2.0
1.4

-

0.8

-
-

3.8
2.8

0.88

-

2.8

-
-
-
-

3.5
2.7
4.9
6.2

1.1@200°F

0.88@200°F

1.7@200°F

1.7

1.8@STP

3.0
2.5
3.3

0.85@200°F

7.0

18

-

-

12.8

-

14.5

-
-

36.0
10.1

-

24.6

-

7.1@200°F

4.8
7.1

-

15.2

-

14.4

22

6.1@302°F

-
-
-

21.0
12.5

19

11.5

14

-

6.7

-
-

15.4
16.0

9.7

-

18.0

-
-
-
-

14.0
36.0
15.9

16

12.7@275°F
8.54@275°F
15.6@200°F

-

14@STP

100

12.0
54.8

7.2@275°F

73
57

-

-

3.4
5.0
3.8

-

4.6
2.6
2.5

-

5.6

-

4.9
3.9
3.5
4.2
2.5
4.4
1.6
3.0
4.7
3.5

5.11

-

3.2
1.0
1.6
3.0
3.5

-

3.7

-

4.0
2.2
2.6
4.5

-

2.1

-
-

4.4
7.2
1.6
1.0
2.8
3.4
4.1

-

3.0

4.72

2.6
1.5
2.1
1.5
4.4
1.0
1.6

-

NEC500

Class I*

Group

IEC

60079

Substance

Auto-Ignition

Temp.*

Flammable Limits** 

Percent by Volume

Flash Point**

Lower

Upper

Vapor

Density**

(Air Equals

1.0)

Appendix

7 _ 8

Appendix

catalog_eng-html.html
background image

Fuel Oils
Furfural
Furfuryl Alcohol
Gasoline
Heptane
Heptene
Hexane
Hexanol
2-Hexanone
Hexenes
sec-Hexyl Acetate
Hydrazine
Hydrogen
Hydrogen Cyanide
Hydrogen Selenide
Hydrogen Sulfide
lsoamyl Acetate
lsoamyl Alcohol
lsobutyl Acrylate

lsobutyraldehyde

lsodecaldehyde
lso-octyl Alcohol
lso-octyl Alcohol
lsophorone
lsoprene
lsopropyl Acetate
lsopropyl Ether
lsopropyl Glycidyl Ether
lsopropylamine
Kerosene
Liquefied Petroleum Gas
Mesityl Oxide
Methane
Methanol
Methyl Acetate
Methyl Acrylate
Methyl Amyl Alcohol
Methyl n-Amyl Ketone
Methyl Ether
Methyl Ethyl Ketone
2-Methyl-5-Ethyl Pyridine
Methyl Formal
Methyl Formate
Methyl lsocyanate
Methyl Mercaptan
Methyl Methacrylate
2-Methyl-1-Propanol
2-Methyl-2-Propanol
alpha-Methyl Styrene
Methylacetylene
Methylacetylene-Propadiene (stabilized)
Methylamine
Methylcyclohexane
Methylcyclohexanol
o-Methylcyclohexanone
Monoethanolamine
Monoisopropanolamine

Table 1.6  Flash Point of the Flammable Materials, Auto Ignition Temperature, Vapor Density

D
C
C
D
D
D
D
D
D
D
D
C
B
C
C
C
D
D
D
C
C
C
C
D
D
D
D
C
D
D
D
D
D
D
D
D
D
D
C
D
D
C
D
D
C
D
D
D
D
C
C
D
D
D
D
D
D

II A

II A

II A
II A

II C

II B

II A

II A

I A

II A
II B
II A

410-765

600
915

536-880

399
500
437

-

795
473

-

74-518

968

1000

-

500
680
662
800
385

-
-

387
860
428
860
830

-

756
410

761-842

652
999
725
850
875

-

740
662
759

-

460
840
994

-

792
780
892

1066

-
-

806
482
565

-

770
705

210-407

316
490

280-471

204
260
225

-

424
245

-

23-270

520
538

-

260
360
350
427
196

-
-

197
460
220
460
443

-

402
210

405-450

344
537
385
454
468

-

393
350
404

-

238
449
534

-

422
416
478
574

-
-

430
250
296

-

410
374

100-336

140
167

-36to-50

25

32

-7

145

77

20

-

100
gas

0

-

gas

77

109

86

-1

185
180

-

184

-65

35

-18

-

-35

110-162

-

87

gas

52
14
27

106
102
gas

16

155

-

-2

19

-

50
82
52

129
gas

-

gas

25

149
118
185
171

38-169

60
75

-38to-46

-4

0

-22

63
25

-7
-

38

gas

-18

-

gas

25
43
30

-18

85
82

-

84

-54

2

-28

-

-37

43-72

-

31

gas

11

-10

-3

41
39

gas

-9

68

-

-19

-7

-

10
28
11
54

gas

-

gas

-4

65
48
85
77

0.7
2.1
1.8

1.2-1.5

1.05

-

1.1

-
-
-
-

2.9
4.0
5.6

-

4.0

1.0@212°F

1.2

-

1.6

-
-
-

0.8
1.5

1.8@100°F

1.4

-
-

0.7

-

1.4

50

6.0
3.1
2.8
1.0

1.1@151°F

3.4

1.7@200°F

1.1

-

4.5
5.3
3.9
1.7

1.7@123°F

2.4
1.9
1.7

-

4.9
1.2

-
-
-
-

5

19.3
16.3

7.1-7.6

6.7

-

7.5

-

8

-
-

9.8

75

40.0

-

44.0

7.5

9.0@212°F

-

10.6

-
-
-

3.8
8.9

8

7.9

-
-

5

-

7.2

15.0

36
16
25

5.5

7.9@250°F

27.0

11.4@200°F

6.6

-

23
26

21.8

8.2

10.6@ 202°F

8.0
6.1

-
-

20.7

6.7

-
-
-
-

-

3.3
3.4

3-4

3.5

3.39

3.0
3.5
3.5
3.0

-

1.1
0.1
0.9

-

1.2
4.5
3.0

4.42

2.5
5.4

-
-
-

2.4
3.5
3.5

-

2.0

-
-

3.4
0.6
1.1
2.8
3.0

-

3.9
1.6
2.5
4.2

-

2.1

1.97

1.7
3.6
2.6
2.6

-

1.4

-

1.0
3.4
3.9
3.9
2.1
2.6

NEC500

Class I*

Group

IEC

60079

Substance

Auto-Ignition

Temp.*

Flammable Limits** 

Percent by Volume

Flash Point**

Lower

Upper

Vapor

Density**

(Air Equals

1.0)

Explosion Proof Technical

Explosion Protection

Appendix

catalog_eng-html.html
background image

Monomethyl Aniline
Monomethyl Hydrazine
Morpholine
Naphtha (Coal Tar)
Naphtha (Petroleum)4
Nitrobenzene
Nitroethane
Nitromethane
1-Nitropropane
2-Nitropropane
Nonane
Nonene
Nonyl Alcohol
Octane
Octene
n-Octyl Alcohol
Pentane
1-Pentanol
2-Pentanone
1-Pentene
Phenylhydrazine
Propane
1-Propanol
2-Propanol
Propiolactone
Propionaldehyde
Propionic Acid
Propionic Anhydride
n-Propyl Acetate
n-Propyl Ether
Propyl Nitrate
Propylene
Propylene Dichloride
Propylene Oxide1
Pyridine
Styrene
Tetrahydrofuran
Tetrahydronaphthalene
Tetramethyl Lead
Toluene
Tridecene
Triethylamine
Triethylbenzene
Tripropylamine
Turpentine
Undecene
Unsymmetrical Dimethyl Hydrazine (UDMH)
Valeraldehyde
Vinyl Acetate
Vinyl Chloride
Vinyl Toluene
Vinylidene Chloride
Xylenes

C
C
C
D
D
D
C
C
C
C
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
C
D
D
D
C
B
D
D

B(C)

D
D
C
D
C
D
D
C
D
D
D
D
C
C
D
D
D
D
D

II A
II A

II A
II A

II A

II A
II A

II A

II B

II A

II A

II A

II A

900
382
590
531
550
900
778
785
789
802
401

-
-

403
446

-

470
572
846
527

-

842
775
750

-

405
870
545
842
419
347
851

1035

840
900
914
610
725

-

896

-

480**

-
-

488

-

480
432
756
882
921

1058

867-984

482
194
310
277
288
482
414
418
421
428
205

-
-

206
230

-

243
300
452
275

-

450
413
399

-

207
466
285
450
215
175
455
557
449
482
490
321
385

-

480

-

249**

-
-

253

-

249
222
402
472
494
570

464-529

185

17
98

107

0

190

82
95
96
75
88
78

165

56
70

178

-40
91
45

0

190
gas

74
53

165

-22

126
145

55
70
68

gas

60

-35

68
88

6

160
100

40

-

16

181
105

95

-

5

54
18

-108.4

127

-19

81-90

85

-8

37
42

-18
88
28
35
36
24
31
26
74
13
21
81

-40
33

7

-18

88

gas

23
12
74

-30

52
63
13
21
20

gas

16

-37

20
31

-14

71
38

4

-

-9

83
41
35

-

-15

12

-8

-78

53

-28

27-32

-

2.5
1.4

-

1.1

1.8@200°F

3.4
7.3
2.2
2.6
0.8

-

0.8@212°F

1.0

-
-

1.5
1.2
1.5
1.5

-

2.1
2.2
2.0
2.9
2.6
2.9
1.3

1.7@100°F

1.3

2

2.0
3.4
2.3
1.8
0.9
2.0

0.8@212°F

-

1.1

-

1.2

-
-

0.8

-

2

-

2.6
3.6
0.8
6.5

1.0-1.1

-

92

11.2

-

5.9

-
-
-
-

11.0

2.9

-

6.1@212°F

6.5

-
-

7.8

10.0@212°F

8.2
8.7

-

9.5

13.7

12.7@200°F

-

17

12.1

9.5

8

7.0

100

11.1
14.5

36

12.4

6.8

11.8

5.0@302°F

-

7.1

-

8.0

-
-
-
-

95

-

13.4
33.0
11.0
15.5

7.0

3.7
1.6
3.0

-

2.5
4.3
2.6
2.1
3.1
3.1
4.4

4.35

5.0
3.9
3.9
4.5
2.5
3.0
3.0
2.4

-

1.6
2.1
2.1
2.5
2.0
2.5
4.5
3.5

3.53

-

1.5
3.9
2.0
2.7
3.6
2.5
4.6
6.5
3.1

-

3.5
5.6
4.9

-
-

2.0
3.0
3.0
2.2
4.1
3.4
3.7

NEC500

Class I*

Group

IEC

60079

Substance

Auto-Ignition

Temp.*

Flammable Limits** 

Percent by Volume

Flash Point**

Lower

Upper

Vapor

Density**

(Air Equals

1.0)

Appendix

9 _ 10

*Data from NFPA 497 - 2004, Recommended Practice for the Classification of Flammable Liquids, Gases, Vapors and of
Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas.
**Data from NFPA 325M-1991, Fire Hazard Properties of Flammable Liquids, Gases, and Volatile Solids.

Appendix

catalog_eng-html.html
background image

Zone 21
locations are
those where
there is a cloud
of combustible
dust  more than
10hours per
year and less
than 1,000
hours per year.

Zone 0 locations
are those where
there is a
flammable
mixture typically
more than 1,000
hours per year.

Zone 1 locations
are those where
there is a
flammable
mixture more
than 10 hours
per year and
less than 1,000
hours per year.

Zone 2 locations
are those where
explosive gas
atmospheres
will exist for
less than 10
hours per year.

Zone 20
locations are
those where
there is a cloud
of combustible
dust typically
more than 1,000
hours per year.

Zone 22
locations are
those where
there is a cloud
of combustible
dust  less than
10 hours per
year.

-

Table 1.7  Comparison Between Divisions & Zones

IEC
Europe CENELEC

Germany
United Kingdom
Korea
Japan
France
Italia
Netherland

Gases and Vapors

Classification /
Country

Dusts

Fibers

& Flying

Zone 0
Zone 0

Zone 0

Zone 0
Division 0

0종 장소
0종 장소

Division 1

Class I

Class II

Division 2

Division 1

-

-
-
-

Zone E
Zone E

Increased Hazard

d

C

ia 
ib
ic

p

px
py
pz

nA
nC
nR

q

o

m

ma
mb

S

1

1
0
1
2
1
1
1
2
2
2
2

1

1

1
0
1
1
2

EN 50 018 

EN 50 019 

EN 50 020
EN 50 020
EN 50 020
EN 50 016
EN 50 016
EN 50 016
EN 50 016
EN 50 021
EN 50 021
EN 50 021

EN 50 017

EN 50 015

EN 50 028
EN 50 028
EN 50 028

National

60079-1

60079-7

60079-11
60079-11
60079-11

60079-2
60079-2
60079-2
60079-2

60079-15
60079-15
60079-15

60079-5

60079-6

60079-18
60079-18
60079-18

-----

Withstand and contain the explosion & prevent transmission of
explosion to surrounding external atmosphe

Removes ignition from explosion triangle through prevention of high
fault current & voltage

Removes fuel from explosion triangle by passing protective gas
through enclosure

No arcs, sparks, or hot surfaces

Electrical components are covered with a filling medium, preventing
presence of explosive gas-air mixtures

Electrical parts are immersed in oil, preventing exposure of arc or
spark to explosive atmosphere

Component parts which could ignite an explosive atmosphere are
enclosed in resin compound

Special protective techniques not covered by Protection standards 

No arcs, sparks, or hot surfaces

Zone 1
Zone 1

Zone 1

Zone 1
Division 0

1종 장소
1종 장소

Zone 20
Zone 20

Zone 20

Zone 20

20종 장소
20종 장소

Zone 21
Zone 21

Zone 21

Zone 21

21종 장소
21종 장소

Zone 22
Zone 22

Zone 22

Zone 22

22종 장소
22종 장소

Zone 2
Zone 2

Zone 2

Zone 2
Divisoin 2

2종 장소
2종 장소

Zone F
Zone F

Limited Hazard

mines
mines

Class III

-
-
-
-
-
-
-

North America /NEC505
(USA, Canada, Mexico)

North America /NEC500
(USA, Canada, Mexico)

Division 2

-

Table 1.8  Types of Protection for Gas / Vapour Hazards

Gases and Vapors

Flameproof

Increased Safety

Pressurization 

Non-Sparking

Powder Filled 

Oil Immersion 

Encapsulation

Special Protection

Protection Principle 

Zone

Symbol

Method of Protection 

Standards

CENELEC

IEC

Increased Safety

Explosion Proof Technical

Explosion Protection

Appendix

catalog_eng-html.html
background image

OPERATION W/EXPLOSION HAZARD
SHUT DOWN W/EXPLOSION HAZARD

ZONE 0
ZONE 1
ZONE 2

ZONE 20
ZONE 21
ZONE 22

I
I

II
II
II
II
II
II

M1

M2 & M1

1G

2G+1G

3G+2G+1G

1D

2D+1D

3D+2D+1D

Appendix

11 _ 12

Table 1.9 Types of Protection for Equipment for Dust Hazards

tDA 20
tDB 20
iaD
maD
tDA 21
tDB 21
ibD
mbD
pD
tDA 22
tDB 22
icD

Equipment Code

Description

Suitable for Zones

Protection by enclosure
Protection by enclosure
Intrinsic Safety
Encapsulation
Protection by enclosure
Protection by enclosure
Intrinsic Safety
Encapsulation
Encapsulation
Protection by enclosure
Protection by enclosure
Intrinsic Safety

Table 1.10 Comparison of Protection Between NEC Article 500 & NEC Article 505

Area

Class I

Class II

Class III

Ignition Protection Type

Ignition Protection Type

Area

Intrinsically Safe, ia(2 fault)Class, 
Div.1 intrinsically Safe (2 fault)

Encapsulation, m
Flameproof, d
Increased Safey, e
Intrinsically Safe, i
bOil Immersion, o
Powder Filling, q
Purged Pressurized,p
Any Class I, Zone 0 method
Any Class I, Div. 1 method

Non-incendive,nC
Non-sparking Device, nA
Restricted Breathing, nR
Hermetically Sealed, nC
Any Class I,Zone 0 method
Any Class  I,Div. 1 method

Non-incendive,nC
Non-sparking Device, nA
Restricted Breathing, nR
Hermetically Sealed, nC
Any Class I,Zone 0 method
Any Class  I,Div. 1 method

Explosion-proof
Intrinsically Safe, e
Purged/Pressurized (Type X or Y)

ZONE 0

ZONE 1

ZONE 2

DIVISION 1

DIVISION 2

DIVISION 1

DIVISION 2

DIVISION 1

DIVISION 2

Dust-ignition Proof
Intrinsically Safe Pressurized

Any Class II, Div.1 method

Dust Thight Intrinsically Safe

Dust Tight 
Any Class II, Div.1 and
Class III method

Dust Tight
Non-incendive
Non-sparking Pressurized

Table 1.11 Condition of Hazardous Area

Area

Methane dust

Gas or Vapour

Dust

Required Marking For Installation

Category

Equipment Group

Classification of The Explosion Hazard

20, 21 , 22
20, 21 , 22
20, 21 , 22
20, 21 , 22
21, 22
21, 22
21, 22
21, 22
21, 22
22
22
22

Note

: UNDERGROUND I, OTHER AREA II, GAS & VAPOR-G, DUST-D, MINE-M

Appendix

catalog_eng-html.html
background image

Table 1.12 Normal Relationship Between EPL And Zone.

EQUIPMENT PROTECTION 
LEVEL (EPL)

NORMAL APPLICABLE ZONE(S)

GAS & VAPOUR

DUST

Ga
Gb
Gc
Da
Db
Dc

-

-

ZONE 0 ( & ZONE 1 & ZONE 2)
ZONE 1( & ZONE 2)
ZONE 2
ZONE 20 ( & ZONE 21 & ZONE 22)
ZONE 21( & ZONE 22)
ZONE 22

Table 1.13 The EPL Awarded to Each Type Of Protection.

EPL CODE

DESCRIPTION

EQUIPMENT CODE

Ga
Gb
Bc
Gb
Gb
Gb
Gb
Gc
Gb
Gb
Ga
Gb
Gb
Gb
Gc

Refer to equipment marking and documentation

Intrinsic safety “ ia”
Intrinsic safety “ ib”
Intrinsic safety “ ic”
Flame-proof protection
Purge/pressurized protection
Purge/pressurized protection “px”
Purge/pressurized protection “py”
Purge/pressurized protection “pz”
Increased safety
Encapsulation
Encapsulation
Encapsulation
Oil immersion
Sand / powder (quartz) filling
Type – n protection
Special protection

Non-protected

Protected against solid
foreign objects of 50mm
diameter and greater

Protected against solid
foreign objects of 12.5mm
diameter and greater

Protected against drops of water falling
vertically

Protected against drops of water falling at up
to 15º from the vertical

Protected against spraying water at up to 60º
from the vertical

Protected against splashing water from all
directions

Protected against jet of water from all
directions

Protected against jet of water of similar force
to heavy seas

Protected against the effects of immersion

Protected against prolonged effects of
immersion under pressure to a specified
depth

Protected against solid
foreign objects of 2.5mm
diameter and greater

Protected against solid
foreign objects of 1.0mm
diameter and greater

Dust-protected

Dust-tight

Protected against Access 
to hazardous parts with 
the back of a hand

Protected against
access to hazardous
parts with a finger

Protected against
access to hazardous
parts with a tool

Protected against
access to hazardous
parts with a wire

Protected against
access to hazardous
parts with a wire

Protected against
access to hazardous
parts with a wire

Non-protected

Non-protected

Table 1.10 Comparison of Protection Between NEC Article 500 & NEC Article 505

First 
Digit

Protection again Solid Foreige Objects

and Access to Hazardous Parts

Illustration

Illustration

Method

Explanation

Method

Protection Against Liquids

Second 

Digit

Ex ia
Ex ib
Ex ic
Ex d
Ex p
Ex px
Ex py
Ex pz
Ex e
Ex m
Ex ma
Ex mb
Ex o
Ex q
Ex n
Ex s

0

1

2

3

4

5

6

0

1

2

3

4

5

6

7

8

50mm

12.5mm

2.5mm

1mm

1mm

1mm

Explosion Proof Technical

Explosion Protection

Appendix

catalog_eng-html.html
background image

Acetylene

Metal dust

Dust - Ignition Proof.

Carbon black,
coal dust,
coke dust

Flour, starch,
grain dust

Metane with or
without coal dust

Fibers, flyings *

Hydrogen 

Manufactured gas

Diethyl ether,

Ethylene

Cyclo-propane

Gasoline, Hexane

Butane, Naphtha

Propane, Acetone

Toluene, Isoprene

Type 7

Explosion-proof

Explosion-proof & Oil - filled.

Type 8

Appendix

13 _ 14

Table 1.15 NEMA vs IP Ratings

NEMA Code

1

2

3

3R

3S

4X

5

4

6P

6

12K

13

12


10



11


54


14




54








65








65



52








67











68





52






54

General Driptigh

Raintight
Dusttight

Weather-
Resistant

Raintight
Dusttight

Driptight

Dusttight

Driptight

Dusttight

Oiltight

Dusttight

Raintight
Watertight

Corrosion
Resistant

Submersible

Corrosion
Resistant

Table 1.16 Comparision Enclosure Between NEC Code  & NEMA Code

Class I

Class II

Class III

MSHA

Marking

Enclosure Type 9, Class II

Enclosure Type 10

-

Enclosure Type 7 and 8, Class 1

NEMA 250 Enclosure for Electrical Equipment (1000V Maximum)

* These fibers and flyings are nonhazardous materials and are not considered Class III type ignitable fibers or combustible

flyins. For Class III type ignitable fibers or combustible flyings see the National Electrical Code, Article 500.

** External operating mechanisms are not required to be operable when the enclosure is ice covered.
*** External operating mechanisms are operable when the enclosure is ice covered. See 5.6. 

* For Class III Type ignitable fibers or combustible flyings see the National Electrical Code, Article 500.
* Due to the characteristics of the gas, vapor, or dust, a product suitable for one Class or Group may not be suitable for another 

Class or Group unless marked on the product.

Incidental contact with the enclosed equipment
Falling dirt
Falling liquids and light splashing
Circulating just, lint, fibers, and flyings *
Settling airborne dust, lint, fibers, and flyings *
Hosedown and splashing water
Oil and coolant seepage
Oil or coolant spraying and splashing
Corrosive agents
Occasional temporary submersion
Occasional prolonged submersion
Rain, snow, and sleet **
Sleet ***
Windblown dust, lint fibers, and flyings
For Indoor
For Outdoor

IEC IP Code

Markings

Group A

Group B

Group C

Group D

Group E

Group F

Group G

Appendix

catalog_eng-html.html
background image

Table 1.17 General Guide for Product Material 

Chemical
Atmosphere

Copper-
Free 
Aluminu

Cast  Iron

Corro-

FreeEpoxy

Coating

Brass

316

Stainless

Steel

Copper-
Free 
Aluminu

Cast  Iron

Corro-

FreeEpoxy

Coating

Brass

316

Stainless

Steel

Chemical
Atmosphere

Acetic Acid

Acetic Anhydride

Acetone

Acetylene

Aluminum Chloride

Aluminum Sulfate

Ammonium Carbonate

Ammonium Chloride

Ammonium Hydroxide

Ammonium Nitrate

Ammonium Phosphate

Amyl Acetate

Amyl Alcohol

Aniline

Arsenious Acid

Asphalt

Barium Carbonate

Barium Chloride

Barium Hydroxide 

Beer

Beet Sugar Liquors

Benzene

Benzoic Acic

Borax

Boric Acid

Bromine, Wet

Butane

Butyl Alcohol

Butyric Acid

Calcium Bisulfite

Calcium Chloride

Calcium Hydroxide

Calcium Hypochlorite

Calcium Sulfate

Cane Sugar Liquors

Carbon Dioxide, Dry

Carbon Dioxide, Wet

Carbon Disulfide

Carbon Tetrachloride

Carbonic Acid

Castor Oil

C

A

A

A

D

C

A

D

A

A

C

A

A

B

A

A

D

D

D

A

A

A

A

B

B

D

A

A

A

A

C

D

B

A

A

A

A

A

A

A

A

C

D

A

A

D

D

A

D

B

B

B

B

A

D

D

A

A

D

A

A

A

A

D

A

A

D

A

B

D

D

B

A

D

A

A

A

B

B

B

B

A

C

C

C

A

A

A

A

A

A

A

A

C

A

B

A

A

A

A

A

A

A

C

A

A

A

C

A

A

C

A

A

A

A

A

A

A

A

C

C

A

A

C

C

A

D

C

C

D

D

D

D

D

A

A

C

C

A

A

C

A

A

A

A

A

A

A

C

A

A

A

C

A

A

C

A

A

A

C

C

A

C

A

A

A

A

A

D

B

A

D

B

A

B

A

B

A

B

A

B

B

A

A

A

A

A

A

B

D

B

A

B

D

D

B

D

B

A

A

A

B

A

B

B

B

A

A

A

A

A

A

D

D

A

A

A

A

A

A

A

B

B

A

B

D

A

A

D

D

A

D

A

B

A

D

D

A

A

B

A

D

A

D

A

B

D

A

A

A

A

A

A

D

D

A

D

C

A

A

B

B

D

A

A

D

A

A

D

D

B

A

B

B

D

A

D

D

D

B

B

A

D

B

C

B

A

A

A

A

C

A

A

A

C

C

A

C

A

A

C

A

C

B

B

A

A

A

A

A

A

A

A

D

B

B

A

A

A

A

A

A

A

C

B

B

B

A

A

A

A

A

A

A

A

D

D

A

C

B

A

A

A

A

B

A

A

A

A

A

A

D

D

A

B

A

B

A

D

C

D

B

A

A

D

A

B

D

A

B

B

B

B

A

B

A

D

D

A

B

B

B

B

A

A

B

B

B

B

A

B

B

D

A

B

A

B

A

B

D

B

B

B

D

B

D

A

C

B

A

Formic Acid

Freons, Dry

Fuel Oil

Furfural

Gasoline

Glue

Glycerine

Concd. Hydrochloric Acid

Hydrofluoric Acid

Hydrogen

Hydrogen Peroxide

Hydrogen Sulfide

Kerosene

Ketones

Lacquers

Lacquer Solvents

Lactic Acid

Lime

Linseed Oil

Magnesium Chloride

Magnesium Hydroxide

Magnesium Sulfate

Marine Atmosphere

Mercuric Chloride

Mercury

Methyl Alcohol

Methyl Chloride

Methyl Ethyl Ketone

Mine Waters

Motor Oil

Nickel Chloride

Nickel Sulfate

Nitric Acid

Oleic Acid

Oxalic Acid

Oxygen

Perchloric Acid

Phenol

Phosphoric Acid

Picric Acid

Potassium Carbonate

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

A – Excellent    B – Good   C – Adequate   D – Unsatisfactory

Explosion Proof Technical

Explosion Protection

Appendix

catalog_eng-html.html
background image

Appendix

15 _ 16

Chemical
Atmosphere

Copper-
Free 
Aluminu

Cast  Iron

Corro-

FreeEpoxy

Coating

Brass

316

Stainless

Steel

Copper-
Free 
Aluminu

Cast  Iron

Corro-

FreeEpoxy

Coating

Brass

316

Stainless

Steel

Chemical
Atmosphere

Chlorine

Chloroform

Citric Acid

Cottonseed Oil

Chromic Acid

Crude Oil

Ethyl Acetate

Ethyl Alcohol

Ethyl Chloride

Ethylene Dichloride

Ethylene Glycol

Fatty Acids

Ferric Chloride

Ferric Sulfate

Formaldehyde

Sodium Hypochlorite

Sodium Nitrate

Sodium Phosphate

Sodium Silicate

Sodium Sulfate

Sodium Sulfite

Stearic Acid

Sulfur

Sulfur Dioxide, Dry

Sulfur Trioxide, Dry

Sulfur Trioxide, Wet

Sulfuric Acid

Sulfurous Acid

D

B

A

A

B

A

A

A

B

A

A

A

D

D

A

D

A

D

B

A

A

A

A

B

A

D

A

B

A

C

D

A

B

A

A

A

B

A

A

B

D

D

B

D

A

A

A

A

B

B

A

A

A

D

D

D

B

B

A

A

C

A

C

A

B

C

A

A

A

A

A

B

A

A

A

A

A

A

A

A

A

B

B

B

D

A

A

A

D

A

A

A

A

A

A

C

D

D

A

B

B

B

A

A

A

B

D

A

A

B

C

B

B

C

B

B

C

A

B

A

A

B

B

B

D

B

B

C

B

B

A

A

B

A

A

B

B

C

D

D

D

D

D

A

A

A

A

B

A

B

B

C

D

D

D

A

A

A

A

A

A

A

B

B

A

A

B

B

B

B

A

A

A

A

B

D

B

D

D

A

B

B

A

B

A

B

A

B

A

A

B

B

A

A

B

B

A

A

B

A

A

A

A

A

A

A

A

A

A

A

B

A

A

B

C

C

A

A

A

B

A

C

A

A

B

D

C

B

A

A

A

A

A

A

B

A

A

D

B

A

A

B

A

A

A

A

A

D

A

A

D

C

B

B

B

B

A

B

A

B

A

B

B

B

B

A

B

B

A

A

A

B

A

B

B

B

B

B

B

A

Postassium Chloride

Potassium Cyanide

Potassium Hydroxide

Potassium Nitrate

Potassium Sulfate

Propane

Rosin

Sea Water

Sodium Bicarbonate

Sodium Bisulfate

Sodium Bisulfite

Sodium Carbonate

Sodium Chloride

Sodium Cyanide

Sodium Hydroxide

Tannic Acid

Tar

Tartaric Acid

Toluene

Trichloroethylene

Turpentine

Vegetable Oils

Vinegar

Vinyl Chloride

Waxes

Xylene

Zinc Chloride

Zinc Sulfate

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

113

114

115

116

117

118

119

120

121

122

123

124

125

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

126

127

128

129

130

131

132

133

134

135

136

137

138

A – Excellent    B – Good   C – Adequate   D – Unsatisfactory

Appendix

catalog_eng-html.html
background image

Index

A2

A2F

ACB

ATS

BCP

BCW

BP

BW

C101

C103

C104

C105

CAS

CCL

CCP

CCS

CGC

CGK

CHG

CHL

CHS

CLEH 02

CLES 03

CLES 08

CLEU 03

CLEU 08

CLN

CLNU 03

CLNU 08

CSES 02

CSEU 02

CSI

CSM

CUB

CVAS

CVS

CW

CWe 

CX

CXe

CXS

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

D10

D25

G3

G3

E34

D18

E38

D11

F13

F13

F14

F14

F9

E33

E33

F11

D9

D8

E32

F13

F13

A39

A18

A18

A4

A4

E47

A11

A11

A25

A21

E30

E30

E34

F11

F8

D12

D26

D13

D27

F6

Page

A

B

C

D

E

F

G

Model

Page

A

B

C

D

E

F

G

Model

CXT

E1FW

E1FX

E1W

E1X

E2FW

E2W

EAG

EARTH TAGS

ECG

ECG-CB

EDF

EGB

EGC

EIB 4030

EIB 5040A

EIB 5040B

EIB 6060A

EIB 6060B

EIB 6060C

EIB-C 2520

EIB-C 3530A

EIB-C 3530B

EJB 1510

EJB 2015

EJB 2322

EJB 3022

EJB 3030H

EJB 4030

EJB 4030H

EJB 5040

EJB 5040H

EJB 5050H

EJB 6040

EJB 7060H

EJB-C 2019

EJB-C 2520

EJB-C 3530

EJB-C 4035

EJB-C 5040

EJB-C 5550

D14

D28

D29

D15

D16

D30

D17

C36

D32

D19

D20

C21

D21

D22

B15

B15

B15

B15

B15

B15

B16

B16

B16

B4

B4

B4

B4

B4

B4

B4

B4

B4

B4

B4

B4

B6

B6

B6

B6

B6

B6

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

catalog_eng-html.html
background image

ELC 120

ELC 200

ELC 92

ELES 4W

ELES 8W

ENTRY THREAD SEAL

EP

EPD 16

EPF

EPG

EPGa

ESG

ESL

ESS

EUAG 90

EUF

EUM

F7LB

F7LC

F7LL

F7LR

F7LT

F7LTB

F7LX

F8LB

F8LL

F8LR

F8LT

F8LTB

FB

FBI

FBIE

FLDS 02

FLDS 03

FLDS 04

FLES 02

FLES 03

FLES 04

FLNS 02

FLNS 03

FLNS 04

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

B18

B18

B18

B45

B45

D32

F31

C46

C19

C38

C38

C36

F31

F31

C33

C33

C33

C27

C27

C27

C27

C27

C27

C27

C29

C29

C29

C29

C29

C44

C44

C44

A32

A32

A32

A28

A28

A28

A30

A30

A30

Index

1 _ 2

FLVS 02

FLVS 03

FLVS 04

FNG

FNGC

FNGS

FUR

GF

GW

HLET 02

HLET 04

HLET 06

HML

HVS

ICP

ILEH 10

ILET 10

ILET 20

ISDS 10

ISDS 20

ISES 10

ISES 20

ISES 30

ISEU 10

ISEU 20

ISEU 30

ISVS 10

ISVS 20

KFAG45 & -E

KFAG90 & -E

KFAT45 & -E

KFAT90 & -E

KFBC & -E

KFBG & -E

KFBT & -E

KFNG

KFUC & -E

KFUG & -E

KFUT & -E

KG

KI

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

A32

A32

A32

C40

C40

C40

E47

E25

E26

A41

A41

A41

F16

G2

G5

A39

A41

A41

A37

A37

A25

A25

A25

A21

A21

A21

A37

A37

E40

E40

E40

E40

E40

E40

E40

E38

E40

E40

E40

E44

E18

Page

A

B

C

D

E

F

G

Model

Page

A

B

C

D

E

F

G

Model

Index

catalog_eng-html.html
background image

Index

Page

A

B

C

D

E

F

G

Model

Page

A

B

C

D

E

F

G

Model

KIB

KIC

KIH

KIO

KIS

KIV

KM

KMB

KMC

KMH

KMO

KMS

KMV

KPS

KUS

LA

LADDER AHC

LADDER ARC

LADDER BC

LADDER CT

LADDER EC

LADDER EJC

LADDER HC

LADDER HE30

LADDER HE45

LADDER HE60

LADDER HE90

LADDER HT

LADDER JC

LADDER RDL

LADDER RDR

LADDER RDS

LADDER TSL

LADDER TSR

LADDER TSS

LADDER VC

LADDER VE30

LADDER VE45

LADDER VE60

LADDER VE90

LADDER VT

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

E22

E21

E20

E21

E19

E20

E18

E22

E21

E20

E21

E19

E20

E24

E23

G2

E58

E58

E58

E48

E59

E59

E50

E52

E52

E51

E51

E50

E59

E56

E56

E56

E57

E57

E57

E53

E55

E55

E54

E54

E53

LBS

LCP

LDP

LHL

LOCK-NUTS

LVS

MCC

MCG

MCP

MLDS 17

MLDS 25

MLDS 40

MLEF 17

MLEF 25

MLEF 40

MLES 17

MLES 25

MLES 40

MLEU 17

MLEU 25

MLEU 40

MLNF 17

MLNF 25

MLNF 40

MLNU 17

MLNU 25

MLNU 40

MLVS 17

MLVS 25

MLVS 40

MOF

MOGUL LB

MOGUL LC

MOGUL LL

MOGUL LR

MOGUL LT

MS

MVS

OHC

OHCB

OHS

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

G2

G4

G4

F13

D33

G3

G4

D23

G5

A34

A34

A34

A43

A43

A43

A18

A18

A18

A4

A4

A4

A45

A45

A45

A11

A11

A11

A34

A34

A34

G2

C31

C31

C31

C31

C31

E46

G2

E31

E32

F13

catalog_eng-html.html
background image

Index

3 _ 4

Index

Page

A

B

C

D

E

F

G

Model

Page

A

B

C

D

E

F

G

Model

OHST

PCP

PDC

PE

PF

PHL

PS

PT

PV

PVF

PVH

PVS

PZ

RB

RHL

RHS

RIGID CONDUIT

RM5

RPL

RPS

RS35

RS42

SCDB

SCN

SDPR 100 4P

SDPR 30 3P

SDPR 30 4P

SDPR 60 4P

SDPR 75 4P

SEACOM-A

SEACOM-X

SEC 1~5

SECB 4030A

SECB 4030B

SECB 5040A

SECB 5040B

SECB 5050A

SECB 5050B

SECB 5050C

SECB 6060A

SECB 6060B

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

E30

G4

G4

E29

G2

F13

E27

G2

E28

C20

E29

E28

E27

G3

F13

F13

E10

F32

F14

F14

F13

F13

C14

E34

B43

B43

B43

B43

B43

C24

C24

B32

B34

B34

B34

B34

B34

B34

B34

B34

B34

SECB 6060C

SECB 7060A

SECB 7060B

SECB 7060C

SECP 40

SECP 63

SECP-C DLL

SECP-C DLS

SECP-C SL

SECP-C SS

SEPB 1G

SEPB 2G

SEPB 3G

SEPD 40

SEPD 63

SEPD-C DLL

SEPD-C DLS

SEPD-C SL

SEPD-C SS

SEPR 100 4P

SEPR 25 1G

SEPR 25 2G

SEPR 25 3G

SEPR 30 3P

SEPR 30 4P

SEPR 60 4P

SERB

SERB-01

SETS 1G

SETS 2G

SETS 3G

SF

SFCB 4030

SFCB 5040

SFCB-C 6529

SHF

SHL

SHROUD

SHS

SH-STB-015L

SH-STB-015LD

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

B34

B34

B34

B34

B52

B52

B59

B59

B59

B59

B28

B28

B28

B48

B48

B55

B55

B55

B55

B40

B40

B40

B40

B40

B40

B40

C10

C10

B30

B30

B30

E25

B20

B22

B24

C22

F13

D33

F13

F30

F25

catalog_eng-html.html
background image

Index

Page

A

B

C

D

E

F

G

Model

Page

A

B

C

D

E

F

G

Model

SH-STB-015LT

SH-STB-025L

SH-STB-035L

SH-STB-065L

SH-STB-1.2F

SH-STB-1.2FW

SH-STB-1.6R

SH-STB-1.6T

SH-STB-100B~600B

SH-STB-100L

SH-STB-10C

SH-STB-150A

SH-STB-16C

SH-STB-2.5C

SH-STB-2.5D

SH-STB-20E-16CT

SH-STB-25C

SH-STB-30E

SH-STB-4C

SH-STB-4U

SH-STB-50C

SH-STB-6C

SH-STB-6U

SH-STB-70C

SI

SIB

SIBM

SIC

SIH

SIJA 4030

SIJA 4040

SIJA 5040

SIJB 2525

SIJB 3030

SIJB 4040

SIJB 5050

SIJB 6050

SIJB 6161

SIJB 7550

SIJB 8060

SIO

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

F25

F25

F25

F25

F23

F24

F24

F24

F27

F25

F23

F27

F24

F24

F24

F26

F23

F26

F23

F29

F23

F24

F29

F24

E18

E22

E45

E21

E20

B10

B10

B10

B11

B11

B11

B11

B11

B11

B11

B11

E21

SIRB

SIS

SIUM

SIV

SJB 1~22

SLCC

SLCCF

SLDS 15

SLDS 20

SLDS 25

SLDS 40

SLEF 15

SLEF 20

SLEF 25

SLEF 40

SLES 10

SLES 15

SLES 25

SLES 40

SLEU 10

SLEU 15

SLEU 25

SLEU 40

SLFF45

SLFF90

SLFM45

SLFM90

SLMM45

SLMM90

SLNF 15

SLNF 20

SLNF 25

SLNF 40

SLNU 10

SLNU 15

SLNU 25

SLNU 40

SLS AL

SLS RA

SLS RL

SLS RP

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

C12

E19

E45

E20

C47

E35

E35

A34

A34

A34

A34

A43

A43

A43

A43

A18

A18

A18

A18

A4

A4

A4

A4

C17

C17

C17

C17

C17

C17

A45

A45

A45

A45

A11

A11

A11

A11

B38

B38

B38

B38

catalog_eng-html.html
background image

Index

5 _ 6

Index

Page

A

B

C

D

E

F

G

Model

Page

A

B

C

D

E

F

G

Model

SLS SL

SLVS 15

SLVS 20

SLVS 25

SLVS 40

SM

SMB

SMC

SMH

SMO

SMS

SMV

SNB45

SNB90

SNRB

SPL

SPS

SS2K

SSDB

SVC

SVD

SVF

SW

SWCC-CB

SWCC-CD

SWCC-CP

SWITCH RACK

SXB

SXL

SXT

THST

TRS

TS32

TS35

UAB16

UEAC

UEB

UEBC

UEBL

UEC

UECC

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

B38

A34

A34

A34

A34

E18

E22

E21

E20

E21

E19

E20

C43

C43

C13

F14

F14

D31

C14

C42

C22

C22

E26

C5

C7

C3

B62

C15

C15

C15

E31

G3

F31

F31

C46

F2

F2

F2

F2

F2

F2

UEE

UELC

UES

UESC

UEVC

UEZC

VCB

VLDS 20

VLDS 25

VLDS 40

VLEF 20

VLEF 25

VLEF 40

VLES 25

VLES 40

VLEU 25

VLEU 40

VLNF 20

VLNF 25

VLNF 40

VLNU 25

VLNU 40

VLVS 20

VLVS 25

VLVS 40

WAC90

WAG90

WAT90

WBC

WBG

WBT

WNG

WUC

WUG

WUT

ZB

ZBI

ZBIE

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

F2

F2

F2

F2

F2

F2

G2

A34

A34

A34

A43

A43

A43

A18

A18

A4

A4

A45

A45

A45

A11

A11

A34

A34

A34

E42

E42

E42

E42

E42

E42

E39

E42

E42

E42

C45

C45

C45

catalog_eng-html.html
background image

Always with

SAMWHA ELECTRIC

SAMWHA ELECTRIC Co., LTD.

555-36, Baekseok-Dong, Seobuk-Gu Cheonan, Chungcheongnam Do, Korea       
TEL: +82-41-552-1574   FAX: +82-41-554-1574

Http: //www.samwhaflex.co.kr  

Copyrigths(c) 2000 SAMWHA ELECTRIC Co., LTD.  All Rights Reserved

SAMWHA

PRODUC

T
GUIDE