background image

Cyprus

Uruguay

Slovenia

Greece

Macedonia

Montenegro

Kosovo

Bosnia and

Herzegovina Serbia

Bulgaria

Georgia

Azerbaijan

Lebanon

Saudi Arabia

Oman

Bahrain

Qatar

Bangladesh

Honduras

Ecuador

Venezuela

Peru

Bolivia

Paraguay

Nicaragua

Costa Rica

Panama

Guatemala

Iceland

Sri Lanka

Pakistan

Kuwait

Iran

Iraq

Jordan

Egypt

Tunisia

Morocco

Algeria

Kenya

Uganda

Tanzania

Namibia

Botswana

Zimbabwe

Mozambique

Zambia

Nigeria

Ghana

Armenia

Portugal

Spain

France

Switzerland

Austria

Italy

Netherlands

Belgium

Luxembourg

Poland

Czech Republic

Slovakia
Hungary

Croatia

Romania

United Kingdom

Ireland

Turkey

Israel

UAE

Vietnam

Philippines

Taiwan

Thailand

Singapore

New Zealand

Chile

Argentina

Colombia

Canada

Russia

Finland

Estonia

Latvia

Lithuania

Belarus

Ukraine

Sweden

Norway

Denmark

Kazakhstan

South Korea

Japan

Mexico

Brazil

Australia

Indonesia

Malaysia

India

South Africa

Myanmar

USA

China

Blomberg, Germany

4

Power Supplies, Surge Protection 
and Device Circuit Breakers

2017 / 2018

You will fi nd our complete 
 product  range at:

phoenixcontact.com

In dialog with customers and partners worldwide

Phoenix Contact is a globally present, Germany-based market leader. Our group 
is synonym for future-oriented components, systems, and solutions in the fi elds of 
electrical engineering, electronics, and automation. A global network across more than 
100 countries, and 15,000 employees ensure a close proximity to our 
customers, which we believe is particularly important.

The wide variety of our innovative products makes 
it easy for our customers to fi nd future-oriented 
solutions for diff erent applications and industries. 
We especially focus on the fi elds of energy, 
infrastructure, process and factory automation.

PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstraße 8
32825 Blomberg, Germany
Phone:  +49  (0)  52  35  3-00
Fax: 

+49  (0)  52  35  3-4  12  00

E-mail: info@phoenixcontact.com
phoenixcontact.com

EN

P

o

w

er Supplies, Surge Pr

otection and De

vice Cir

cuit 

Br

eak
ers   

   2017 

/ 2018

4

phoenixcontact-protection-html.html
background image

Terminal blocks

• Terminal blocks

Power supplies, surge protection and device circuit breakers

Interface technology and
switching devices

•  Electronic switching devices and motor control
•  Measurement and control technology
• Monitoring
• Relay modules
•  System cabling for controllers

Automation

•  Lighting and signaling
•  Fieldbus components and systems
• Functional safety
•  HMIs and industrial PCs
• I/O systems
•  Industrial cloud computing
•  Industrial communication technology
• Software
• Controllers

PCB terminal blocks and
PCB connectors

To quickly select a product, use our e-Paper.

 

Web code:

 

#1517

You will fi nd the latest information and all new 
products directly in the product area of our website:

phoenixcontact.net/products

Also discover the Phoenix Contact catalog app
interactively on your tablet.

Sensor/actuator cabling
and connectors

• Sensor/actuator cabling
•  Cables and lines
• Connectors

Marking systems, tools and
mounting material

•  Marking and labeling
• Tools
•  Installation and mounting material

Find out more 
with the web code

On some of the catalog pages, you can fi nd our webcode: a hash 
symbol followed by a four-digit number combination.

 

Web code:

 #1234 (example)

This allows you to access information on our website quickly.

It could not be easier:

1. Go to the Phoenix Contact website
2. Enter # and the number combination in the 

search field

3. Get more information and product versions

Search

Or use the direct link:

phoenixcontact.net/webcode/#1234

phoenixcontact-protection-html.html
background image

Table of contents

Overview

The illustrated table of contents will help you find the right product more quickly

 4

Surge protection and interference suppression filters

 7

Power supplies and UPS

 198

Device circuit breakers

 306

Technical information

 336

Index

 350

phoenixcontact-protection-html.html
background image

4

PHOENIX CONTACT

Introduction

Product range overview

Surge protection for the power supply

Type 1/2 combination protective device

FLASHTRAB SEC HYBRID ...

Page 28

FLASHTRAB SEC PLUS 440 ...

Page 29

FLASHTRAB SEC PLUS 350 ...

Page 31

FLASHTRAB SEC PLUS 264 ...

Page 34

Type 1/2 combination protective device

POWERTRAB

Page 40

VALVETRAB MS T1/T2

Page 36

Type

 

1+2 protective device 

combination

FLASHTRAB SEC T1+T2...

Page 42

Type 2 surge protective device

VALVETRAB SEC

Page 45

VALVETRAB MS

Page 52

Set solutions
 

Isolating spark gap

Type 3 device protection

PLUGTRAB SEC / PT

Page 71

BLOCKTRAB

Page 73

MAINTRAB

Page 74

Building set

Page 76

FLASHTRAB ISG

Page 78

Surge protection for measurement and control technology
 

Surge protection for information technology

DIN rail modules

TERMITRAB complete

Page 92

PLUGTRAB

Page 96

LINETRAB

Page 100

Special systems

Page 101

LSA-PLUS modules

Page 102

For networks

Page 142

For interfaces

Page 144

MAINTRAB

Page 74

TERMITRAB complete

Page 150

PLUGTRAB PT-IQ

Page 163

Surge protection for transceiver systems
 

EMC solutions

Lightning monitoring 
system 

For mobile phone networks

Page 176

For video communication

Page 177

For radio and television sets

 

Page 180

Mains interference filters with integrated 

surge protection

Page 184

Interference suppression filters

Page 187

LM-S

Page 188

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

5

PHOENIX CONTACT

Introduction

Product range overview

Test devices

Power supplies

CHECKMASTER 2

Page 192

QUINT POWER with NFC

Page 206

QUINT POWER

Page 210

QUINT POWER, 

with protective coating

Page 216

TRIO

 

POWER

Page 218

UNO

 

POWER

Page 226

DC/DC converters
 

Redundancy modules

MINI POWER

Page 234

STEP

 

POWER

Page 238

QUINT DC/DC converters

Page 248

QUINT DC/DC converters, 

with protective coating

Page 254

MINI

 

DC/DC converters

Page 256

QUINT ORING

Page 260

QUINT S-ORING

Page 262

QUINT DIODE

Page 264

TRIO DIODE

Page 266

UNO DIODE, STEP DIODE

Page 267

UPS for the control cabinet
 

QUINT DC UPS

QUINT UPS

Page 274

QUINT/TRIO AC UPS

QUINT UPS

Page 280

TRIO UPS-2G

Page 282

Energy storage for

QUINT UPS

Page 284

UPS with integrated energy storage

QUINT

 

UPS

Page 294

QUINT

 

BUFFER

Page 295

STEP

 

UPS, UNO

 

UPS

Page 298

Device circuit breakers

UPS with integrated power supply

TRIO

 

UPS

Page 300

MINI

 

UPS

Page 301

Multi-channel electronic circuit breakers – 

CBM/CBMC

Page 310

Single-channel device circuit breakers

Page 318

TCP thermal circuit breakers

Page 334

Fuse terminal blocks, see Catalog 1

phoenixcontact-protection-html.html
background image

6

PHOENIX CONTACT

phoenixcontact-protection-html.html
background image

 

Basics

 8

 

 

Surge protection for the power supply

 12

 

 

Selection guide

 16

 

 

Applications

 20

 

 

Type 1/2 combination protective device

 28

 

 

Type 1+2 protective device combination

 42

 

 

Type 2 surge protective device

 45

 

 

Type 3 device protection

 71

 

 

Isolating spark gap

 78

 

 

Surge protection for measurement and control 
technology

 80

 

 

Selection guide

 84

 

 

Applications

 86

 

 

Protection for current loops

 92

 

 

Protection for digital signals

 104

 

 

Protection for resistance-dependent measurements

 120

 

 

Single-stage protective devices

 124

 

 

Protection for EX applications

 128

 

 

Surge protection for information technology and 
telecommunications

 136

 

 

Selection guides

 138

 

 

Applications

 140

 

 

Protection for data interfaces

 142

 

 

Protection for fieldbus systems

 150

 

 

Protection for telecommunications interfaces

 162

 

 

Surge protection for transceiver systems

 170

 

 

Selection guide

 172

 

 

Applications

 174

 

 

Protection for antenna systems

 176

 

 

Protection for TV and radio systems

 180

 

 

Interference suppression filters

 182

 

 

Lightning current measurement

 188

 

 

Test devices

 192

 

 

Accessories for surge protection

 196

 

7

PHOENIX CONTACT

Damage caused by surge voltages

The number of electrical devices damaged 

or destroyed by surge voltages is increasing 
year on year. This can prove expensive in 
terms of repairs and downtimes. In an 
industrial environment, the hazards are not 
only restricted to systems and devices. 
Building technology applications and even 
residential buildings may be affected.

Interference voltages

Switching operations triggered 

mechanically or electronically generate 
pulse-like and high-frequency interference 
voltages. These voltages spread in an 
unimpeded manner across the cable 
network. All the devices within this cable 
network are affected. Data errors, 
uncontrolled functions, and system crashes 
can result, with electronic and data 
processing devices at particular risk.

Your web code: 

#0142

Surge protection and interference suppression filters

phoenixcontact-protection-html.html
background image

8

PHOENIX CONTACT

Surge protection and interference suppression filters

Basics

Lightning discharge

It is above all lightning strikes (lightning 

electromagnetic pulse, LEMP) that have the 
greatest potential for damage among all the 
causes of occurrence.

They cause transient overvoltages that 

can extend across great distances and are 
often associated with high-amplitude surge 
currents.

Even the indirect effects of a lightning 

strike can lead to a surge voltage of several 
kilovolts and result in a surge current of tens 
of thousands of amperes. In spite of the very 
brief duration, such an event can lead to 
total failure or even the destruction of the 
entire system.

Switching operations

Switching operations (switching 

electromagnetic pulse, SEMP) can generate 
induced surge voltages that spread to supply 
lines. In the case of large switch-on currents 
or short circuits, very high currents can flow 
within a few milliseconds. These short-term 
current changes can lead to transient 
overvoltages.

Electrostatic discharge

Electrostatic discharge (ESD) occurs if 

exposed conductive parts with different 
electrostatic potential approach each other 
and result in a charge exchange. A sudden 
charge exchange leads to a brief surge 
voltage. This presents a hazard, especially 
for sensitive electronic components.

Surge voltage – what are the effects?

Regardless of what causes a surge voltage, 

the consequences are the same:
– Device  destruction
– System downtimes
– Total failure of controllers

Device failure or defects caused by surge 

voltages are more frequent than expected. 
For non-private systems the consequences 
of a failure are generally much more 
serious, such as downtimes or data loss. 
The failure of a device or a machine that is 
used in a professional environment often 
leads to costs that are many times higher 
than repairing the defective device.

Surge voltage – how can you provide 
correct protection?

Effective surge protection starts with 

assessing the potential risk and identifying 
all the devices within the item to be 
protected. The resulting protection concept 
takes into account all the interfaces of the 
power supply unit as well as those for data 
and telecommunications. This is the only 
way to comprehensively and effectively 
protect all the terminal devices, for 
example, within a data network, production 
plant or building installation. Combining 
high-quality protective devices with 
innovative arrester technology, surge 
protective devices ensure a high degree of 
system availability and safety in all areas of 
electrical engineering.

Surge voltage – what is it?
 
 

Your web code: 

#1133

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

A clear illustration of the lightning 

protection zone concept is the protective 
circle.

An imaginary circle should be drawn 

around the object to be protected. A surge 
protective device should be installed at all 
points where cables intersect this circle.

The area within the protective circuit is 

therefore protected in such a way that 
conducted surge voltage couplings are 
prevented.

The protective circle must include all 

electrical and electronic transmission lines 
in the following areas:
– Power  supply
– Measurement and control technology
– Information technology
– Transceiver systems

9

PHOENIX CONTACT

The protective circle principle

Surge protection for transceiver systems

Surge protection for information technology

Surge protection for MCR technology

Surge protection for power supplies

Surge protection and interference suppression filters

Basics

phoenixcontact-protection-html.html
background image

10

PHOENIX CONTACT

Surge protection and interference suppression filters

Basics

Surge protection for power supplies

Type 1/2 combination protective 
device

Type 1/2 surge protective devices must 

satisfy the highest requirements in terms of 
amplitude and specific energy from surge 
voltages, as they are supposed to protect 
against the effects of direct lightning strikes. 
In the typical installation environment of the 
main distribution, the demand placed on the 
short-circuit withstand capability is also 
often very high. In order to be able to meet 
these requirements, powerful technology is 
required, such as spark gap technology.

Type 2 protective device

Type 2 surge protective devices are 

generally installed in sub-distributions or 
machine control cabinets. These SPDs must 
be able to discharge induced surge voltages 
from indirect lightning strikes or switching 
operations but not handle direct lightning 
strikes. As such, the energy input is 
significantly reduced. In any case, induced 
surge voltages caused by switching 
operations are often very dynamic. Here, a 
technology with fast response behavior 
stands up to the test, e.g., varistor 
technology.

Type 3 device protection

Type 3 surge protective devices are 

generally installed immediately before the 
terminal device to be protected. Due to 
differing installation environments, type 3 
SPDs are available in a very wide range of 
designs.
– Devices for DIN rail mounting
– Devices for insertion in sockets
– Devices for direct mounting on a PCB of 

the terminal device

Combination protective device or a 
combination of protective devices?

Lightning currents are simulated with 

surge currents in the 10/350 μs pulse shape. 
Switching surge voltages and remote 
lightning strikes are simulated with surge 
currents in the 8/20 μs pulse shape.

According to IEC 61643-11 product 

standard requirements, a type 2 protective 
device must only be able to discharge 8/20 
pulses. A type 1 SPD is designed for both 
8/20 μs pulses as well as for 10/350 μs 
pulses. In this way, a type 1 SPD is the same 
as a type 2 SPD. Exhibiting the test class II 
for a type 1 SPD is therefore a redundant 
piece of information and provides no 
additional qualification. Such SPDs are 
referred to as combination protective 
devices (type 1/2 SPDs). This is a protective 
device that satisfies both test categories.

In the case of a protective device 

combination such as the FLT-SEC-T1+T2, 
however, a voltage-switching spark gap (SPD 
type 1/2) is coordinated directly with a 
voltage-limiting varistor (SPD type 2) that is 
connected in parallel. Two autonomous 
protective devices ensure optimum 
response behavior, the best possible system 
protection, and a long component service 
life.

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

11

PHOENIX CONTACT

Surge protection and interference suppression filters

Basics

Surge protection 
for MCR technology

The range of different applications 

presents a particular challenge to surge 
protection for measurement and control 
technology. Different signal types, 
interfaces, and fieldbus systems require a 
tailor-made product and a wide product 
range. Various protective circuits are 
therefore available that are specially 
optimized for the application.

Primarily, a distinction is made between 

two signal types: independent closed loops 
and signals with a common reference 
conductor or a shared return conductor.

The independent closed loops are often 

designed so that they are isolated from the 
ground potential for immunity to 
interference.

Surge protection 
for information technology

In the area of information technology, the 

various interfaces operate with low signal 
levels at high frequencies. This makes them 
particularly sensitive to surge voltages and 
can lead to the destruction of electronic 
components in IT systems. The surge 
protective devices must therefore also have 
high-quality signal transmission behavior, as 
otherwise, malfunctions can be expected in 
the data transmission. Affected interfaces 
could, for example, be as follows: Ethernet, 
serial, and telecommunications interfaces.

Surge protection 
for transceiver systems

Typical areas of application in the field of 

transceiver systems are the antenna 
connections of television and radio 
receivers, video communication, and mobile 
phone systems. Antenna cables which 
extend beyond a building and are usually 
very long, plus the antennas themselves, are 
directly exposed to atmospherical 
discharge. Surge voltages can even reach the 
sensitive interfaces of transceiver systems 
via this cable path.

phoenixcontact-protection-html.html
background image

12

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

Safe Energy Control (SEC) 
technology

The new surge protective devices with 

SEC Technology represent an easy-to-
install product range which combines 
maximum performance and superior 
durability. Electrical equipment is reliably 
protected and maintenance costs are 
reduced. Installation of protective devices 
with SEC Technology is easy, cost-effective, 
and space-saving.

Isolated and durable

A consistent surge protection concept 

requires a powerful type 1 lightning current 
arrester. Conventional type 1 spark gaps 
burden the installation with high line follow 
currents, which can also cause the surge 
protection upstream to be triggered. The 
lightning current arresters in the SEC range 
are the first of their kind to feature spark 
gap technology with no line follow current. 
The avoidance of line follow currents 
benefits the entire installation. This not only 
applies to the protected equipment, but the 
entire supply, including the arrester. 
Maximum system availability is achieved 
because the fuse protection upstream is not 
triggered.

Solution without backup fuse for 
every application

The powerful combination protective 

devices and surge protective devices with 
Safe Energy Control Technology provide a 
solution without separate arrester backup 
fuse for all common applications. For 
applications where the protection of the 
installation is the top priority, type 1 and 
type 2 protective devices can be used for 
main fuse ratings of 315 A gG without 
separate overcurrent protection. For 
applications beyond this scope, products are 
available with integrated surge-proof fuse, 
such as the FLT-SEC-HYBRID. The type 3 
protective devices in the PLT-SEC family can 
be operated in branch wiring without any 
kind of backup fuse, which is also thanks to 
the integrated surge-proof fuses.

Compact and consistent pluggable 
design

With the FLT-SEC-PLUS-440, the SEC 

range offers the most compact type 1 spark 
gap for this nominal voltage, with the 
VAL-SEC the narrowest type 2 arrester, and 
with the FLT-SEC-T1+T2 the only directly 
coordinated combination of type 1 spark 
gap and type 2 varistor arrester in a 
confined space. All products in the SEC 
range have a pluggable design. Maintenance 
work is therefore made much easier.

Everything in the green – we're 
betting that you won't see red for five 
years

With the low-wear surge protective 

devices in the SEC range, you won't have to 
think about replacing wear parts for at least 
five years. Thanks to the SEC technology, 
the high-quality components are particularly 
durable. However, should the status 
indicator signal the need for replacement 
within the first five years following purchase, 
you will receive a free replacement device.

Your web code: 

#0143

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

13

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

New spark gaps

The newly developed spark gaps in the 

type 1 arresters are isolated and extremely 
powerful thanks to the use of technology 
with no line follow current. This increases 
the durability of the components in your 
system.

Type 1/2 combination protective 
device with integrated arrester 
backup fuse

The FLT-SEC-HYBRID

 combines surge 

protection and a backup fuse in a single 
connector. It is no longer necessary to 
install a separate arrester backup fuse. This 
saves space and reduces installation costs.

The power package

Maximum discharge capacity in an 

extremely compact design. And all for 
continuous voltages up to 440 V. The ideal 
type 1/2 combination protective device for 
use in industry and wind turbine generators.

Lightning current and surge 
protection

Reliable protection and minimal 

installation effort, thanks to the narrowest 
coordinated combination or true type 1 
spark gaps and type 2 varistor arresters.

Ultra narrow

With an overall width of just 12.5 mm per 

channel, the type 2 surge protective devices 
provide outstanding protection in a 
minimum amount of space - they can be 
used up to 315 A in the branch without a 
backup fuse.

Powerful type 3 device protection

Integrated surge-proof fuses eliminate the 

need for a separate fuse in the branch. This 
saves space and simplifies planning.

phoenixcontact-protection-html.html
background image

14

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

 

Type 1/2 combination protective 
devices for harsh industrial 
environments

With a rated voltage of 800 V AC, a 

discharge capacity of 35 kA per channel, and 
a robust housing design, POWERTRAB is 
ideal for harsh industrial environments and 
use in 690 V IT networks, such as in wind 
turbine generators.

Type 1/2 combination protective 
devices for lightning protection class 
III and IV

The VAL-MS T1/T2 

 varistor-based 

combination protective devices meet the 
requirements of lightning protection class III 
and IV and also provide the voltage 
protection level of a type 2 surge protective 
device.

Type 2 surge protection for higher 
nominal voltages

With VAL-MS..., corresponding arresters 

are available for power supplies with higher 
supply voltages, such as in wind turbine 
generators or when discharge currents 
> 30 kA per channel are required.

Type 3 device protection in an 
extremely compact design

Ideal for protecting terminal devices, 

type 3 device protection is used in deep 
installation boxes, cable ducts or underfloor 
systems.

Type 3 device protection as an 
attachment plug

The MAINTRAB device protection range 

is very easy to retrofit in existing 
installations. Versions are available as simple 
adapters for mains sockets or with 
additional signal interfaces.

Surge protection for LED lights

The surge protective devices for LED 

applications are specifically designed for 
street, tunnel or object lighting. Different 
versions available for protection class I 
and II.

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

15

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

 

Surge protection with residual 
current device

VAL-CP-RCD

 are combinations of 

type 2 device protection with residual 
current device. They therefore combine 
personal protection and surge protection in 
a single device.

Surge protection with integrated 
arrester backup fuse

VAL-CP-MCB

 are combinations of 

type 2 surge protection with integrated, 
surge-proof circuit breakers as arrester 
backup fuses.

Surge protection for 60 mm system 
technology

VAL-CP-MOSO

 are type 2 surge 

protective devices with integrated, 
surge-proof arrester backup fuse for 
installation on 60 mm system technology.

Surge protection for photovoltaic 
systems

The product range comprises individual 

components for all types of photovoltaic 
systems, from 600 V DC up to 1500 V DC.

Surge protection set

The basic solution for building 

installations. The GEB-SET

 consists of a 

type 1/2 combination protective device and 
three MAINTRAB device protection plugs.

phoenixcontact-protection-html.html
background image

N

L1

PE

L2

L3

L1

PEN

L2
L3

N

L1

PE

PEN

L1

N

L1

PE

L2

L3

L1

PEN

L2
L3

N

L1

PE

PEN

L1

Standard applications

Network type

IEC test classification / EN type

I / T1 I / T1+ 

I+II / T1+T2 II / T2 III / T3

3-p

h

a

s

e

TN

-S

/T

T

230

 /

 400 

V

TN-C

23

0 / 400 

V

1-ph

as

e

TN-S/TT

230 V

TN-C

230 V

Note

Products bearing this stamp 

(plug elements) can be tested 

with the CHECKMASTER.

Selection guide for 230/400 V 
systems

The selection matrix makes it easy to 

select suitable surge protection for the 
desired application.

Further application recommendations 

are available on request.

Special installation requirements

Network type

IEC test classification / EN type

I / T1 I / T1+ 

I+II / T1+T2 II / T2 III / T3

3-ph

as

e

TN

-S

/T

T

23

0 / 400 

V




TN

-C

230 /

 400 

V



1-ph

as

e

TN-S/TT

230

 V




TN-C

2

30 V

16

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Surge protective device (SPD)

Order No.

Page

FLT-SEC-P-T1-3S-350/25-FM

2905421

 31

FLT-SEC-H-T1-3C-264/25-FM

+ FLT-SEC-P-T1-N/PE-350/100-FM

2905871

 + 

2905472

 28

FLT-SEC-T1+T2-3S-350/25-FM

2905470

 42

VAL-SEC-T2-3S-350-FM

2905340

 46

PLT-SEC-T3-3S-230-FM

2905230

 71

FLT-SEC-P-T1-3C-350/25-FM

2905419

 31

FLT-SEC-H-T1-3C-264/25-FM

2905871

 28

FLT-SEC-T1+T2-3C-350/25-FM

2905469

 42

VAL-SEC-T2-3C-350-FM

2905339

 46

FLT-SEC-P-T1-1S-350/25-FM

2905415

 33

FLT-SEC-H-T1-1C-264/25-FM

+ FLT-SEC-P-T1-N/PE-350/100-FM

2801615

 + 

2905472

 28

FLT-SEC-T1+T2-1S-350/25-FM

2905466

 43

VAL-SEC-T2-1S-350-FM

2905333

 47

PLT-SEC-T3-230-FM

2905229

 71

FLT-SEC-P-T1-1C-350/25-FM

2905414

 33

FLT-SEC-H-T1-1C-264/25-FM

2801615

 28

FLT-SEC-T1+T2-1C-350/25-FM

2905465

 44

Surge protective device (SPD)

Order No.

Page

FLT-SEC-P-T1-3S-264/50-FM

Where I

imp

 = 50 kA in the L-N mode of protection

2909589

 34

VAL-SEC-T2-3S-350/40-FM

Where I

n

 = 40 kA in the N-PE mode of protection

2909635

 45

VAL-SEC-T2-3S-350VF-FM

Free of leakage current

2909590

 46

VAL-CP-RCD-3S/40/0.3

Combination with RCD

2882802

 67

VAL-CP-MCB-3S-350/40/FM

Combination with MCB

2882750

 66

VAL-CP-MOSO 60-3S-FM

Combination with MCB for 60 mm rail system

2804403

 68

GEB-SET-T1/T2 TAE/TV-SAT

Set solution for building installation

2801022

 76

FLT-SEC-P-T1-3C-264/50-FM

Where I

imp

 = 50 kA in the L-N mode of protection

2907390

 34

VAL-SEC-T2-3C-350VF-FM

Free of leakage current

2909591

 46

VAL-CP-MCB-3C-350/40/FM

Combination with MCB

2882776

 66

VAL-CP-MOSO 60-3C-FM

Combination with MCB for 60 mm rail system

2804416

 68

FLT-SEC-P-T1-1S-264/50-FM

Where I

imp

 = 50 kA in the L-N mode of protection

2907388

 35

VAL-SEC-T2-1S-350VF-FM

Free of leakage current

2909592

 47

VAL-CP-MCB-1S-350/40/FM

Combination with MCB

2882763

 66

MNT-1 D

Attachment plug 

2882200

 74

BT-1S-230AC/A

Universal mounting (acoustic)

2803409

 73

BT-1S-230AC/O

Universal mounting (optical)

2800625

 73

FLT-SEC-P-T1-1C-264/50-FM

Where I

imp

 = 50 kA in the L-N mode of protection

2907387

 35

17

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

N

L1

PE

L2

L3

L1

PEN

L2
L3

L1

PE

L2

L3

L1

PE

L2
N

L2

L1

PEN

N

L1

PE

PEN

L1

DC-/+

DC+/-

P

E

L-

L+

P

E

Network type

IEC test classification/EN type

I / T1 I / T1+ 

I+II/T1+T2 II / T2 III / T3

3-

p

h

a

s

e

TN-S/TT

120 /

208 V

400 /

690 V

TN

-C

120 /

208 V

400 /

690 V

554 /

960 V

IT

400 V

500 - 

690 V

2-ph

as

e

TN-

S/

T

T

120 /

208 V

TN

-C

120 /

208 V

1-p

h

as

e

TN-S/TT

120 V

TN-C

120 V

Lin

e

ar 

DC

 so

u

r

c

e

24 / 

48 V

24 V

48 V

120 V

220 V

380 V

P

h

oto

v

olta

ics

 

DC s

o

u

r

c

e

1 s

t

r

in

g

600 V

1000 V

1500 V

Note

Products bearing this stamp 

(plug elements) can be tested 

with the CHECKMASTER.

Selection guide for other 
network types

The selection matrix makes it easy to 

select suitable surge protection for the 
desired application. Further application 
recommendations on request.

18

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Surge protective device (SPD)

Order No.

Page

VAL-SEC-T2-3S-175-FM

2905354

 48

FLT-SEC-P-T1-3S-440/35-FM

2908264

 29

VAL-MS-T1/T2 175/12.5/3+0-FM

2800672

 37

VAL-SEC-T2-3C-175-FM

2905353

 48

FLT-SEC-P-T1-3C-440/35-FM

2905988

 29

FLT-SEC-H-T1-3C-440/25-FM

2907260

 28

VAL-SEC-T2-3C-440-FM

2909968

 45

PWT 100-800AC-FM

2800531

 40

VAL-MS 750/30/3+0-FM

2920272

 56

FLT-SEC-P-T1-3C-440/35-FM

2905988

 29

FLT-SEC-H-T1-3C-440/25-FM

2907260

 28

VAL-SEC-T2-3C-440-FM

2909968

 45

PWT 100-800AC-FM

2800531

 40

VAL-MS 750/30/3+0-FM

2920272

 56

VAL-SEC-T2-2S-175-FM

2905351

 49

VAL-SEC-T2-2C-175-FM

2905350

 49

VAL-MS-T1/T2 175/12.5/1+1-FM

2800674

 37

VAL-SEC-T2-1S-175-FM

2905348

 49

PLT-SEC-T3-120-FM

2905228

 71

VAL-MS 120 ST + VAL-MS BE/FM

2807586

 + 

2817738

 58

VAL-MS-T1/T2 48/12.5/1+1V-FM

2801533

 38

VAL-SEC-T2-2+0-48DC-FM

2907865

 50

PLT-SEC-T3-24-FM

2905223

 71

PLT-SEC-T3-60-FM

2905225

 71

VAL-SEC-T2-2+0-120DC-FM

2907874

 50

PLT-SEC-T3-120-FM

2905228

 71

VAL-SEC-T2-2+0-220DC-FM

2907875

 51

PLT-SEC-T3-230-FM

2905229

 71

VAL-SEC-T2-2+0-380DC-FM

2907876

 51

VAL-MS-T1/T2 600DC-PV/2+V-FM

2801164

 41

VAL-MS 600DC-PV/2+V-FM

2800641

 65

VAL-MS-T1/T2 1000DC-PV/2+V-FM

2801161

 41

VAL-MS 1000DC-PV/2+V-FM

2800627

 65

VAL-MB-T1/T2 1500DC-PV/2+V-FM

2905640

 41

VAL-MB-T2 1500DC-PV/2+V-FM

2905646

 64

19

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

P

E

N

P

E

N

FLASHTRAB

FLT-SEC-H

T1-264/25-P

T1 +

FLASHTRAB

FLT-SEC-H

T1-264/25-P

T1 +

FLASHTRAB

FLT-SEC-H

T1-264/25-P

T1 +

L1

F1

L

2

L

3

L1

L

2

L

3

S

6

S

P

E

N

S

L

Type 1 protection for the power supply with integrated arrester backup fuse

FLT-SEC-HYBRID

Branch wiring in the TN-C network

Technical characteristics

Typical installation location

Upstream or downstream of the circuit breaker of low-voltage 

distribution boards with large load currents

Lightning protection class

I, II, III, IV

Lightning protection zone 

transition

LPZ 0

A

 

 LPZ 1

Coordination

Coordination with type 2 arresters of the SEC family is 

guaranteed

Connecting cables

– The required conductor cross sections must be taken from 

the table.

– The connection to the main grounding rail (S

) is absolutely 

essential (see figure).

– For  S

, use a minimum cross section of 16 mm². If this 

connection (S

) is to be equal to the connection to the 

protective conductor (S

PEN

) in the application, use a minimum 

cross section of 35 mm² for S

PEN

.

– If the cable cross section is greater than 35 mm², make sure 

that the surge protection connecting cables (S

L

) are protected 

against ground faults and short circuits. Recommendation: 

use temperature-stable cables for S

L

, e.g., 

XLPE/EPR-insulated cables.

– Lay the connecting cables as short as possible, without 

loops, and with the largest possible bending radii.

Backup fuses

– Can be used without backup fuse in branch wiring

– The integrated overcurrent protection is selective to upstream 

F1 fuses 

 400 A gG

Products in the catalog

Page 28

S

L

mm²

S

PEN

mm²

35

35

Table 1: Connecting cables

U

max

I

max

AC

AC

DC

DC

250 V

125 V (UL)

125 V

30 V

1 A

1 A (UL)

0.2 A

1 A

0.14 mm² ... 1.5 mm²

Table 2: Remote signaling data

20

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

P

E

N

P

E

N

F1

L1

L

2

L

3

L1

L

2

L

3

F

2

FLASHTRAB

FLT-SEC-P

T1-350/25-P

T1

FLASHTRAB

FLT-SEC-P

T1-350/25-P

T1

FLASHTRAB

FLT-SEC-P

T1-350/25-P

T1

S

6

S

P

E

N

S

L

For further information and full technical data, visit phoenixcontact.net/products

Technical characteristics

Typical installation location

Where the cable enters the building or in the pre-meter or 

post-meter area

Lightning protection class

I, II, III, IV

Lightning protection zone 

transition

LPZ 0

A

LPZ 1

Coordination

Coordination with type 2 arresters of the SEC family is 

guaranteed

Connecting cables

– The required conductor cross sections must be taken from 

the tables.

– The connection to the main grounding rail (S

) is absolutely 

essential (see figure).

– For  S

, use a minimum cross section of 16 mm². If this 

connection (S

) is to be equal to the connection to the 

protective conductor (S

PEN

) in the application, use a minimum 

cross section of 16 mm² for S

PEN

.

– Lay the connecting cables as short as possible, without 

loops, and with the largest possible bending radii.

Backup fuses

– Can be used without backup fuse in branch wiring up to 

315 A gG

– If the surge protection fuse needs to be selective to the 

upstream installation, a separate F2 backup fuse is required. 

Once F2 has tripped, there is no more surge protection for the 

system.

– Can be used without backup fuse in through wiring up to 

125 A gG

Products in the catalog

Page 29

F1

A gG

F2

A gG

S

L

mm²

S

PEN

(S

PEN

= S

)

mm²

40

50

63

6

10

10

6 (16)

10 (16)

10 (16)

80

100

125

10

16

16

10 (25)

16 (25)

16 (25)

160

25

25

200

25

25 (35)

250

35

35

315

2 x 25

2 x 25

400

 250

35

35

 500

 315

2 x 25

2 x 25

Table 1: Branch wiring

F1

A gG

S

L

mm²

S

PEN

(S

PEN

= S

)

mm²

40

50

10

10

10 (16)

10 (16)

63

10

10 (25)

80

16

16 (25)

100

25

25

125

35

35

Table 2: Through wiring

U

max

I

max

AC

AC

DC

DC

250 V

125 V (UL)

125 V

30 V

1 A

1 A (UL)

0.2 A

1 A

0.14 mm² ... 1.5 mm²

Table 3: Remote signaling data

Type 1 protection for the power supply

FLT-SEC-PLUS

Branch wiring in the TN-C network

21

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

L1

F1

L

2

L

3

N

P

E

L1

L

2

L

3

N

P

E

VALVETRAB

VAL-SEC
T2-350-P

T2

VALVETRAB

VAL-SEC
T2-350-P

T2

VALVETRAB

VAL-SEC
T2-350-P

T2

VALVETRAB

VAL-SEC
T2-350-P

T2

VALVETRAB

VAL-SEC
T2-350-P

T2

FLASHTRAB

FLT-SEC-P

T1-N/PE-350/100-P

N/PE

VALVETRAB

VAL-SEC
T2-350-P

T2

FLASHTRAB

FLT-SEC

T1-350/25-P

T1

FLASHTRAB

FLT-SEC

T1-350/25-P

T1

FLASHTRAB

FLT-SEC

T1-350/25-P

T1

F

2

S

6

S

P

E

S

L

S

N

F1

A gG

F2

A gG

S

L

 = S

N

mm²

S

PE

(S

PE

 = S

)

mm²

40

50

63

6

10

10

6 (16)

10 (16)

10 (16)

80

100

125

10

16

16

10 (25)

16 (25)

16 (25)

160

25

25

200

25

25(35)

250

35

35

315

2 x 25

2 x 25

400

 250

35

35

 500

 315

2 x 25

2 x 25

Table 1: Branch wiring

F1

A gG

S

L

 = S

N

mm²

S

PE

(S

PE

 = S

)

mm²

40

50

10

10

10 (16)

10 (16)

63

10

10 (25)

80

16

16 (25)

100

25

25

125

35

35

Table 2: Through wiring

U

max

I

max

AC

AC

DC

DC

250 V

125 V (UL)

125 V

30 V

1 A

1 A (UL)

0.2 A

1 A

0.14 mm² ... 1.5 mm²

Table 3: Remote signaling data

Type 1+2 protection for the power supply

FLT-SEC-T1+T2

Branch wiring in the TN-S network

Technical characteristics

Typical installation location

Where the cable enters the building in the post-meter area

Lightning protection class

I, II, III, IV

Lightning protection zone 

transition

LPZ 0

A

LPZ 2

Coordination

Coordination with type 3 arresters of the 

SEC family is guaranteed

Connecting cables

– The required conductor cross sections must be taken from 

the tables.

– The connection to the main grounding rail (S

) is absolutely 

essential (see figure).

– For  S

, use a minimum cross section of 16 mm². If this 

connection (S

) is to be equal to the connection to the 

protective conductor (S

PE

) in the application, use a minimum 

cross section of 16 mm² for S

PE

.

– Lay the connecting cables as short as possible, without 

loops, and with the largest possible bending radii.

Backup fuses

– Can be used without backup fuse in branch wiring up to 

315 A gG

– If the surge protection fuse needs to be selective to the 

upstream installation, a separate F2 backup fuse is required. 

Once F2 has tripped, there is no more surge protection for the 

system.

– Can be used without backup fuse in through wiring up to 

125 A gG

Products in the catalog

Page 42

22

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

L1

F1

L

2

L

3

N

P

E

L1

L

2

L

3

N

P

E

F

2

VALVETRAB

VAL-SEC
T2-350-P

T2

VALVETRAB

VAL-SEC
T2-350-P

T2

VALVETRAB

VAL-SEC
T2-350-P

T2

VALVETRAB

VAL-SEC-T2

N/PE-350-P

N/PE

S

P

E

S

L

S

N

For further information and full technical data, visit phoenixcontact.net/products

Technical characteristics

Typical installation location

In sub-distributions or level distributions upstream of the RCD

Lightning protection zone 

transition

LPZ 0

B

LPZ 1

LPZ 1

LPZ 2

Coordination

Coordination with type 1 and type 3 arresters of the SEC family 

is guaranteed

Connecting cables

– The required conductor cross sections must be taken from 

the tables.

– For backup fuses > 200 A in relation to PVC-insulated copper 

cables, it is not possible to clamp a sufficient cross section for 

short circuits and ground faults. Special measures must 

therefore be implemented in this area to ensure that the 

connecting cables are protected against short circuits and 

ground faults. Prevent the cables from touching each other or 

touching conductive components, e.g., by using spacers, or 

use cables with increased temperature stability (e.g., 

XLPE/EPR-insulated cables).

– Lay the connecting cables as short as possible, without 

loops, and with the largest possible bending radii.

Backup fuses

– Can be used without backup fuse in branch wiring up to 

315 A gG

– If the surge protection fuse needs to be selective to the 

upstream installation, a separate F2 backup fuse is required. 

Once F2 has tripped, there is no more surge protection for the 

system.

– Can be used without backup fuse in through wiring up to 

63 A gG

Products in the catalog

Page 46

F1

A gG

F2

A gG

S

L

 = S

N

mm²

S

PE

mm²

25

32

40

50

63

6

6

6

6

6

6

6

6

6

6

80

100

10

10

10

10

125

160

16

16

16

16

200

250

315

25

25

25

25

25

25

400

 250

25

25

 500

 315

25

25

Table 1: Branch wiring

F1

A gG

S

L

 = S

N

mm²

S

PE

mm²

25

32

40

6

6

6

6

6

6

50

63

10

10

10

10

Table 2: Through wiring

U

max

I

max

AC

AC

DC

DC

250 V

125 V (UL)

125 V

30 V

1 A

1 A (UL)

0.2 A

1 A

0.14 mm² ... 1.5 mm²

Table 3: Remote signaling data

Type 2 protection for the power supply

VAL-SEC

Branch wiring in the TN-S network

23

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

F1

DC +/-

F1

F

2

DC -/+

P

E

DC +/-

DC -/+

P

E

VALVETRAB

VAL-SEC

T2-220DC-P

T2

VALVETRAB

VAL-SEC

T2-220DC-P

T2

Technical characteristics

Typical installation location

Main and sub-distribution

Lightning protection zone 

transition

LPZ 0

B

LPZ 1

LPZ 1

LPZ 2

Coordination

Coordination with type 3 SPDs of the SEC family is guaranteed.

Connecting cables

– For branch wiring, the connecting cables and cross sections 

only have to be designed for short circuits and ground faults. 

– For through wiring, operating current and overload also have 

to be taken into account.

– Lay the connecting cables as short as possible, without 

loops, and with the largest possible bending radii

Backup fuses

– The required backup fuses must be taken from the tables.

Products in the catalog

Page 51

Prospective short-circuit 

current I

p

 at installation 

location

Backup fuse (F2)

200 A

-

> 200 A

20 A (gG / MCB characteristic B)

Backup fuses for U

N

 

 220 V DC

Prospective short-circuit 

current I

p

 at installation 

location

Backup fuse (F2)

100 A

-

> 100 A

10 A (gG / MCB characteristic B)

> 200 A

20 A (gG / MCB characteristic B)

Backup fuses for U

N

 

 400 V DC

U

max

I

max

AC

AC

DC

DC

250 V

125 V (UL)

125 V

30 V

1 A

1 A (UL)

0.2 A

1 A

0.14 mm² ... 1.5 mm²

Table 3: Remote signaling data

Type 2 protection for the power supply

VAL-SEC DC

Branch wiring in insulated 
DC voltage systems

24

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

L

F1

N

P

E

L

N

P

E

11

12

PLUGTRAB

PLT-SEC
T3-230-P

T3

L

F1

N P

E

11

12

PLUGTRAB

PLT-SEC
T3-230-P

T3

L

N P

E

I

N

OUT

For further information and full technical data, visit phoenixcontact.net/products

U

max

I

max

AC

DC

DC

250 V

125 V

30 V

3 A

0.2 A

1 A

0.2 mm² ... 2.5 mm²

Table 1: Remote signaling data

Type 3 protection for the power supply

PLT-SEC

Through wiring and branch wiring 
in the TN-S network

Technical characteristics

Typical installation location

Upstream of the terminal device to be protected

Lightning protection zone 

transition

LPZ 2

LPZ 3

Coordination

Coordination with type 2 arresters of the SEC family is 

guaranteed

Connection

– Max. conductor cross section 4 mm² solid and 2.5 mm² 

stranded

– The maximum load current I

L

 is 26 A for through wiring

Backup fuses

– Can be used without backup fuse for prospective short-circuit 

currents up to 1500 A

– The integrated overcurrent protection is selective to upstream 

F1 fuses 

 16 A gG

– For backup fuses > 40 A, make sure that the connecting 

cables are protected against ground faults and short circuits.

Recommendation:

 use cables with increased temperature 

stability, such as XLPE/EPR-insulated cables.

Products in the catalog

Page 71

25

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

L1

F1

F

2

L

2

L

3

N

P

E

L1

L

2

L

3

N

P

E

Technical characteristics

Typical installation location

In sub-distributions in place of an RCD

Lightning protection zone 

transition

LPZ 0

B

LPZ 1

LPZ 1

LPZ 2

Coordination

Coordination with type 1 and type 3 arresters of the SEC family 

is guaranteed

RCD

The RCD used is a type A/type A selective

Connection

– The conductor cross sections are based on the 

upstream F1 overcurrent protection device

– F1 

 50 A 

  6 mm²

– F1 > 50 A 

 10 mm²

– Lay the connecting cables as short as possible, without 

loops, and with the largest possible bending radii

– The maximum load current I

L

 is 40 A

Backup fuses

– Can be used without backup fuse in branch and through 

wiring up to 63 A gG

Products in the catalog

Page 67

Type 2 protection for the power supply

VAL-CP-RCD

Branch wiring in the TN-S network

26

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

L1

F1

L

2

L

3

N

P

E

L1

L

2

L

3

N

P

E

For further information and full technical data, visit phoenixcontact.net/products

F1

A gG

S

L

 = S

N

mm²

S

PE

 

mm²

63

80

10

10

10

10

100

125

16

16

16

16

160

200

25

25

25

25

250

35

2 x 16

> 250

35

2 x 16

Table 1: Branch wiring

U

max

I

max

AC

DC

250 V

250 V 

2 A

0.05 A

0.14 mm² ... 1.5 mm²

Table 2: Remote signaling data

Type 2 protection for the power supply

VAL-CP-MCB

Branch wiring in the TN-S network

Technical characteristics

Typical installation location

In sub-distributions or level distributions upstream of the RCD

Lightning protection zone 

transition

LPZ 0

B

LPZ 1

LPZ 1

LPZ 2

Coordination

Coordination with type 1 and type 3 arresters of the SEC family 

is guaranteed

Connecting cables

– The required conductor cross sections must be taken from 

the table

– For backup fuses > 250 A in relation to PVC-insulated copper 

cables, it is not possible to clamp a sufficient cross section for 

short circuits and ground faults. Special measures must 

therefore be implemented in this area to ensure that the 

connecting cables are protected against short circuits and 

ground faults. Prevent the cables from touching each other or 

touching conductive components, e.g., by using spacers, or 

use cables with increased temperature stability (e.g., 

XLPE/EPR-insulated cables).

– Lay the connecting cables as short as possible, without 

loops, and with the largest possible bending radii

Backup fuses

– Can be used without backup fuse in branch wiring

– The integrated overcurrent protection is selective to upstream 

F1 fuses 

 63 A gG

Products in the catalog

Page 66

27

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

12

14

FM

11

PEN

L1

L2

L3

12

14

FM

11

L

PEN

 

 

 

 

Technical data

Technical data

Electrical data

... 264

... 440

... 264

... 440

IEC test classification

I / II , T1 / T2

I / II , T1 / T2

I / II , T1 / T2

I / II , T1 / T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-C)

400/690

 

V

 

AC

 

(TN-C)

 

/

400

 

V

 

AC

 

(IT)

240

 

V

 

AC

 

(TN-C)

400

 

V

 

AC

 

(TN)

 

/

400

 

V

 

AC

 

(IT)

Mode of protection

L-PEN

L-PEN / L-PE

L-PEN

L-N / L-PE / L-PEN / N-PE (4+0)

Maximum continuous operating voltage U

C

264 V AC

440 V AC

264 V AC

440 V AC

Impulse discharge current I

imp

 (10/350) µs

25 kA

25 kA

25 kA

25 kA

Nominal discharge  current I

n

 (8/20) µs

25 kA

25 kA

25 kA

25 kA

Max. discharge current I

max

 (8/20)µs

50 kA

50 kA

50 kA

50 kA

Protection level U

p

 1.5 kV

 2.5 kV

 1.5 kV

 2.5 kV

Follow current interrupt rating I

fi

50 kA

50 kA

50 kA

50 kA

Response time tA

 100 ns

 100 ns

 100 ns

 100 ns

Short-circuit current rating I

SCCR

50 kA

50 kA

50 kA

50 kA

General data

Dimensions W/H/D

106.8 mm / 167 mm / 74.5 mm

35.5 mm / 167 mm / 74.5 mm

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Description

U

C

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

FLASHTRAB

264 V AC

FLT-SEC-H-T1-3C-264/25-FM

2905871

1

FLT-SEC-H-T1-1C-264/25-FM

2801615

1

440 V AC

FLT-SEC-H-T1-3C-440/25-FM

2907260

1

FLT-SEC-H-T1-1C-440/25-FM

2907259

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

FLT-SEC-H-T1-264/25-P

2905968

1

FLT-SEC-H-T1-264/25-P

2905968

1

L-N / L-PEN

FLT-SEC-H-T1-440/25-P

2907261

1

FLT-SEC-H-T1-440/25-P

2907261

1

Wiring bridge, 

35

 

mm²

6-pos.

MPB 18/1-6/35

2908705

10

MPB 18/1-6/35

2908705

10

8-pos.

MPB 18/1-8/35

2908704

10

MPB 18/1-8/35

2908704

10

28

PHOENIX CONTACT

– Integrated combination of spark gap 

without line follow current and 
surge-proof fuse

– Can be used without separate backup 

fuse thanks to integrated overcurrent 
protection

– Free of leakage current, suitable for use in 

the pre-meter area

– 440 V versions satisfy TOV requirements 

for use in IT systems

– Can be inserted with innovative push-pull 

locking mechanism

– Low voltage protection level of 1.5 kV for 

264 V and 2.5 kV for 440 V versions

– Optical, mechanical status indicator
– With floating remote indication contact
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

new

H

W

D

new

Type 1/2 combination protective device
FLASHTRAB SEC HYBRID

Surge protection and interference suppression filters

Surge protection for the power supply

4-conductor system; 

L1, L2, L3, PEN

2-conductor system; 

L, PEN

phoenixcontact-protection-html.html
background image

12

14

11 FM

N

PE

L2

L1

L3

12

14

FM

11

PE(N)

L2

L1

L3

For further information and full technical data, visit phoenixcontact.net/products

 

 

Technical data

Technical data

Electrical data

IEC test classification

I / II , T1 / T2

I / II , T1 / T2

Nominal voltage U

N

400/690

 

V

 

AC

 

(TN-S)

 

/

400/690

 

V

 

AC

 

(TT)

400/690

 

V

 

AC

 

(TN-C)

 

/

400

 

V

 

AC

 

(IT)

Mode of protection

L-N / L-PE / N-PE

L-PE / L-PEN

Maximum continuous operating voltage U

C

440 V AC

440 V AC

Impulse discharge current I

imp

 (10/350) µs

35 kA / 35 kA / 100 kA

35 kA

Nominal discharge  current I

n

 (8/20) µs

35 kA / 35 kA / 100 kA

35 kA

Max. discharge current I

max

 (8/20)µs

50 kA / 50 kA / -

50 kA

Protection level U

p

 2.5 kV / 

 4.5 kV / 

 2.5 kV

 2.5 kV

Follow current interrupt rating I

fi

50 kA / 50 kA / 100 A

50 kA

Response time tA

 100 ns

 100 ns

Short-circuit current rating I

SCCR

50 kA

50 kA

Max. backup fuse with branch wiring

400 A (gG)

400 A (gG)

General data

Dimensions W/H/D

142.4 mm / 95.2 mm / 74.5 mm

106.8 mm / 95.2 mm / 74.5 mm

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

FLASHTRAB

FLT-SEC-P-T1-3S-440/35-FM

2908264

1

FLT-SEC-P-T1-3C-440/35-FM

2905988

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

FLT-SEC-P-T1-440/35-P

2905989

1

FLT-SEC-P-T1-440/35-P

2905989

1

N-PE

FLT-SEC-P-T1-N/PE-440/100-P

2907263

1

29

PHOENIX CONTACT

– Spark gap has no line follow current
– Free of leakage current, suitable for use in 

the pre-meter area

– Satisfies TOV requirements for use in 

IT systems

– Pluggable
– Low voltage protection level of 2.5 kV
– Optical, mechanical status indicator
– With floating remote indication contact
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

new

H

W

D

Type 1/2 combination protective device
FLASHTRAB SEC PLUS 440

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; 

L1, L2, L3, N, PE

4-conductor system, 

L1, L2, L3, PE(N)

phoenixcontact-protection-html.html
background image

12

14

FM

11

L

PE(N)

12

14

11 FM

N

PE

 

 

Technical data

Technical data

Electrical data

IEC test classification

I / II , T1 / T2

I / II , T1 / T2

Nominal voltage U

N

400

 

V

 

AC

 

(TN)

 

/

400

 

V

 

AC

 

(IT)

400

 

V

 

AC

 

(TN - only N-PE)

 

/

400

 

V

 

AC

 

(TT - only N-PE)

Mode of protection

L-N / L-PE / L-PEN / N-PE (4+0)

N-PE

Maximum continuous operating voltage U

C

440 V AC

440 V AC

Impulse discharge current I

imp

 (10/350) µs

35 kA

100 kA

Nominal discharge  current I

n

 (8/20) µs

35 kA

100 kA

Max. discharge current I

max

 (8/20)µs

50 kA

-

Protection level U

p

 2.5 kV

 2.5 kV

Follow current interrupt rating I

fi

50 kA

100 A

Response time tA

 100 ns

 100 ns

Short-circuit current rating I

SCCR

50 kA

-

Max. backup fuse with branch wiring

400 A (gG)

-

General data

Dimensions W/H/D

35.6 mm / 95.2 mm / 74.5 mm

35.6 mm / 95.2 mm / 74.5 mm

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

FLASHTRAB

FLT-SEC-P-T1-1C-440/35-FM

2905987

1

FLT-SEC-P-T1-N/PE-440/100-FM

2907262

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

FLT-SEC-P-T1-440/35-P

2905989

1

N-PE

FLT-SEC-P-T1-N/PE-440/100-P

2907263

1

30

PHOENIX CONTACT

– Spark gap has no line follow current
– Free of leakage current, suitable for use in 

the pre-meter area

– Satisfies TOV requirements for use in 

IT systems

– Pluggable
– Low voltage protection level of 2.5 kV
– Optical, mechanical status indicator
– With floating remote indication contact
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

new

Type 1/2 combination protective device
FLASHTRAB SEC PLUS 440

Surge protection and interference suppression filters

Surge protection for the power supply

2-conductor system, 

L, PE(N)

N-PE spark gap

phoenixcontact-protection-html.html
background image

12

14

11 FM

N

PE

L2

L1

L3

PEN

L1

L3

L2

12

14

11

FM

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

I / II , T1 / T2

I / II , T1 / T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-C)

Mode of protection

L-N / L-PE / N-PE

L-PEN

Maximum continuous operating voltage U

C

350 V AC

350 V AC

Impulse discharge current I

imp

 (10/350) µs

25 kA / 25 kA / 100 kA

25 kA

Nominal discharge  current I

n

 (8/20) µs

25 kA / 25 kA / 100 kA

25 kA

Max. discharge current I

max

 (8/20)µs

50 kA / 50 kA / -

50 kA

Protection level U

p

 1.5 kV / 

 2.5 kV / 

 1.5 kV

 1.5 kV

Follow current interrupt rating I

fi

50 kA / - / 100 A

50 kA

Response time tA

 100 ns

 100 ns

Short-circuit current rating I

SCCR

50 kA

50 kA

Max. backup fuse with branch wiring

315 A (gG)

315 A (gG)

General data

Dimensions W/H/D

142.4 mm / 95.2 mm / 74.5 mm

106.8 mm / 95.2 mm / 74.5 mm

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

UL connection data

AWG

12 ... 2

12 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

UL connection data

AWG

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

FLASHTRAB

FLT-SEC-P-T1-3S-350/25-FM

2905421

1

FLT-SEC-P-T1-3C-350/25-FM

2905419

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

FLT-SEC-P-T1-350/25-P

2905422

1

FLT-SEC-P-T1-350/25-P

2905422

1

N-PE

FLT-SEC-P-T1-N/PE-350/100-P

2905473

1

31

PHOENIX CONTACT

– Spark gap has no line follow current
– Free of leakage current, suitable for use in 

the pre-meter area

– Pluggable
– High continuous voltage of 350 V AC for 

230/400 V AC networks with high voltage 
fluctuations

– Low voltage protection level of 1.5 kV
– Optical, mechanical status indicator
– With floating remote indication contact
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 1/2 combination protective device
FLASHTRAB SEC PLUS 350

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; 

L1, L2, L3, N, PE

4-conductor system; 

L1, L2, L3, PEN

phoenixcontact-protection-html.html
background image

12

14

11 FM

N

PE

L2

L1

PEN

L1

L2

12

14

11

FM

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

I / II , T1 / T2

I / II , T1 / T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-C)

Mode of protection

L-N / L-PE / N-PE

L-PEN

Maximum continuous operating voltage U

C

350 V AC

350 V AC

Impulse discharge current I

imp

 (10/350) µs

25 kA / 25 kA / 100 kA

25 kA

Nominal discharge  current I

n

 (8/20) µs

25 kA / 25 kA / 100 kA

25 kA

Max. discharge current I

max

 (8/20)µs

50 kA / 50 kA / -

50 kA

Protection level U

p

 1.5 kV / 

 2.5 kV / 

 1.5 kV

 1.5 kV

Follow current interrupt rating I

fi

50 kA / - / 100 A

50 kA

Response time tA

 100 ns

 100 ns

Short-circuit current rating I

SCCR

50 kA

50 kA

Max. backup fuse with branch wiring

315 A (gG)

315 A (gG)

General data

Dimensions W/H/D

106.8 mm / 95.2 mm / 74.5 mm

71.2 mm / 95.2 mm / 74.5 mm

71.2 mm / 95.2 mm / 74.5 mm

35.6 mm / 95.2 mm / 74.5 mm

35

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

UL connection data

AWG

12 ... 2

12 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

UL connection data

AWG

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 1

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A A

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

FLASHTRAB

FLT-SEC-P-T1-2S-350/25-FM

2905418

1

FLT-SEC-P-T1-2C-350/25-FM

2905416

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

FLT-SEC-P-T1-350/25-P

2905422

1

FLT-SEC-P-T1-350/25-P

2905422

1

N-PE

FLT-SEC-P-T1-N/PE-350/100-P

2905473

1

32

PHOENIX CONTACT

– Spark gap has no line follow current
– Free of leakage current, suitable for use in 

the pre-meter area

– Pluggable
– High continuous voltage of 350 V AC for 

230/400 V AC networks with high voltage 
fluctuations

– Low voltage protection level of 1.5 kV
– Optical, mechanical status indicator
– With floating remote indication contact
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

Type 1/2 combination protective device
FLASHTRAB SEC PLUS 350

Surge protection and interference suppression filters

Surge protection for the power supply

4-conductor system; 

L1, L2, N, PE

3-conductor system; 

L1, L2, PEN

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

12

14

11 FM

N

PE

L

PEN

L1

12

14

11

FM

12

14

11 FM

N

PE

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Technical data

I / II , T1 / T2

I / II , T1 / T2

I / II , T1 / T2

240

 

V

 

AC

 

(TN-S)

 

/

240

 

V

 

AC

 

(TT)

240

 

V

 

AC

 

(TN-C)

 

/

240

 

V

 

AC

 

(TT)

240

 

V

 

AC

 

(TN - only N-PE)

 

/

240

 

V

 

AC

 

(TT - only N-PE)

L-N / L-PE / N-PE

L-PEN

N-PE

350 V AC

350 V AC

350 V AC

25 kA / 25 kA / 100 kA

25 kA

100 kA

25 kA / 25 kA / 100 kA

25 kA

100 kA

50 kA / 50 kA / -

50 kA

-

 1.5 kV / 

 2.5 kV / 

 1.5 kV

 1.5 kV

 1.5 kV

50 kA / - / 100 A

50 kA

100 A

 100 ns

 100 ns

 100 ns

50 kA

50 kA

-

315 A (gG)

315 A (gG)

-

Dimensions W/H/D

106.8 mm / 95.2 mm / 74.5 mm

71.2 mm / 95.2 mm / 74.5 mm

71.2 mm / 95.2 mm / 74.5 mm

35.6 mm / 95.2 mm / 74.5 mm

35.6 mm / 95.2 mm / 74.5 mm

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

12 ... 2

12 ... 2

12 ... 2

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

PDT contact

PDT contact

PDT contact

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

30 ... 14

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

FLT-SEC-P-T1-1S-350/25-FM

2905415

1

FLT-SEC-P-T1-1C-350/25-FM

2905414

1

FLT-SEC-P-T1-N/PE-350/100-FM

2905472

1

Accessories

Accessories

Accessories

FLT-SEC-P-T1-350/25-P

2905422

1

FLT-SEC-P-T1-350/25-P

2905422

1

FLT-SEC-P-T1-N/PE-350/100-P

2905473

1

FLT-SEC-P-T1-N/PE-350/100-P

2905473

1

33

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

H

W

D

3-conductor system; 

L, N, PE

2-conductor system; 

L, PEN

N-PE spark gap

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

12

14

11 FM

N

PE

L2

L1

L3

PEN

L1

L3

L2

12

14

11

FM

Technical data

Technical data

Electrical data

IEC test classification

I / II , T1 / T2

I / II , T1 / T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-C)

Mode of protection

L-N / L-PE / N-PE

L-PEN

Maximum continuous operating voltage U

C

264 V AC / 264 V AC / 350 V AC

264 V AC

Impulse discharge current I

imp

 (10/350) µs

50 kA / 50 kA / 100 kA

50 kA

Nominal discharge  current I

n

 (8/20) µs

50 kA / 50 kA / 100 kA

50 kA

Max. discharge current I

max

 (8/20)µs

100 kA

100 kA

Protection level U

p

 2.5 kV / 

 3 kV / 

 1.5 kV

 2.5 kV

Follow current interrupt rating I

fi

50 kA / - / 100 A

50 kA

Response time tA

 100 ns

 100 ns

Short-circuit current rating I

SCCR

50 kA

50 kA

Max. backup fuse with branch wiring

500 A (gG)

500 A (gG)

General data

Dimensions W/H/D

142.4 mm / 95.2 mm / 74.5 mm

106.8 mm / 95.2 mm / 74.5 mm

71.2 mm / 95.2 mm / 74.5 mm

35.6 mm / 95.2 mm / 74.5 mm

3

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

UL connection data

AWG

-

-

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

UL connection data

AWG

-

-

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 1

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A A

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

FLASHTRAB

FLT-SEC-P-T1-3S-264/50-FM

2909589

1

FLT-SEC-P-T1-3C-264/50-FM

2907390

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

FLT-SEC-P-T1-264/50-P

2907391

5

FLT-SEC-P-T1-264/50-P

2907391

5

N-PE

FLT-SEC-P-T1-N/PE-350/100-P

2905473

1

34

PHOENIX CONTACT

– Spark gap has no line follow current
– Free of leakage current, suitable for use in 

the pre-meter area

– Pluggable
– High lightning impulse current of 50 kA 

per position

– Low voltage protection level of 2.5 kV
– Optical, mechanical status indicator
– With floating remote indication contact
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

Type 1/2 combination protective device
FLASHTRAB SEC PLUS 264

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; 

L1, L2, L3, N, PE

4-conductor system; 

L1, L2, L3, PEN

H

W

D

new

H

W

D

new

phoenixcontact-protection-html.html
background image

12

14

11 FM

N

PE

L

PEN

L1

12

14

11

FM

12

14

11 FM

N

PE

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

Technical data

Technical data

Technical data

I / II , T1 / T2

I / II , T1 / T2

I / II , T1 / T2

240

 

V

 

AC

 

(TN-S)

 

/

240

 

V

 

AC

 

(TT)

240

 

V

 

AC

 

(TN-C)

 

/

240

 

V

 

AC

 

(TT)

240

 

V

 

AC

 

(TN - only N-PE)

 

/

240

 

V

 

AC

 

(TT - only N-PE)

L-N / L-PE / N-PE

L-PEN

N-PE

264 V AC / 264 V AC / 350 V AC

264 V AC

350 V AC

50 kA / 50 kA / 100 kA

50 kA

100 kA

50 kA / 50 kA / 100 kA

50 kA

100 kA

100 kA

100 kA

-

 2.5 kV / 

 3 kV / 

 1.5 kV

 2.5 kV

 1.5 kV

50 kA / - / 100 A

50 kA

100 A

 100 ns

 100 ns

 100 ns

50 kA

50 kA

-

500 A (gG)

500 A (gG)

-

Dimensions W/H/D

142.4 mm / 95.2 mm / 74.5 mm

106.8 mm / 95.2 mm / 74.5 mm

71.2 mm / 95.2 mm / 74.5 mm

35.6 mm / 95.2 mm / 74.5 mm

35.6 mm / 95.2 mm / 74.5 mm

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

-

-

12 ... 2

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

PDT contact

PDT contact

PDT contact

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

-

-

30 ... 14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

FLT-SEC-P-T1-1S-264/50-FM

2907388

1

FLT-SEC-P-T1-1C-264/50-FM

2907387

1

FLT-SEC-P-T1-N/PE-350/100-FM

2905472

1

Accessories

Accessories

Accessories

FLT-SEC-P-T1-264/50-P

2907391

5

FLT-SEC-P-T1-264/50-P

2907391

5

FLT-SEC-P-T1-N/PE-350/100-P

2905473

1

FLT-SEC-P-T1-N/PE-350/100-P

2905473

1

35

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

H

W

D

new

3-conductor system; 

L, N, PE

2-conductor system; 

L, PEN

N-PE spark gap

H

W

D

new

H

W

D

new

phoenixcontact-protection-html.html
background image

12

14

11

FM

N

L1

L2

L3

12

14

11

FM

N

L1

L2

L3

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

...335

...335

IEC test classification

I / II , T1 / T2

I / II , T1 / T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-S)

Mode of protection

L-N / L-PE / N-PE

L-PE / N-PE

Maximum continuous operating voltage U

C

335 V AC / 335 V AC / 264 V AC

335 V AC

Impulse discharge current I

imp

 (10/350) µs

12.5 kA / 12.5 kA / 50 kA

12.5 kA

Nominal discharge  current I

n

 (8/20) µs

12.5 kA / 12.5 kA / 50 kA

12.5 kA

Max. discharge current I

max

 (8/20)µs

50 kA

50 kA

Protection level U

p

 1.2 kV / 

 2 kV / 

 1.7 kV

 1.2 kV

Response time tA

 25 ns / 

 100 ns / 

 100 ns

 25 ns

Short-circuit current rating I

SCCR

25 kA

25 kA

Max. backup fuse with branch wiring

160 A (gG)

160 A (gG)

General data

Dimensions W/H/D

71.2 mm / 99 mm / 77.5 mm

71.2 mm / 99 mm / 77.5 mm

IEC connection data

Solid/stranded/AWG

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

1.5

UL connection data

AWG

10 ... 2

10 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

UL connection data

AWG

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 30 V DC

250 V AC / 30 V DC

Max. operating current

1.5 A AC / 1 A DC

1.5 A AC / 1 A DC

Ordering data

Ordering data

Description

U

C

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB-MS, 

varistor-based lightning current arrester

with remote indication contact

335 V AC

VAL-MS-T1/T2 335/12.5/3+1-FM

2800183

1

VAL-MS-T1/T2 335/12.5/4+0-FM

2800644

1

without remote indication contact

335 V AC

VAL-MS-T1/T2 335/12.5/3+1

2800184

1

VAL-MS-T1/T2 335/12.5/4+0

2800645

1

175 V AC

Accessories

Accessories

Replacement plug

335

 

V

 

AC

L-N / L-PEN

VAL-MS-T1/T2 335/12.5 ST

2800190

10

VAL-MS-T1/T2 335/12.5 ST

2800190

10

175

 

V

 

AC

L-N / L-PEN

N-PE

F-MS-T1/T2 50 ST

2800191

10

36

PHOENIX CONTACT

– Consistent pluggability (even for N/PE 

spark gap)

– Secure hold of plugs in the event of high 

lightning current loads and strong 
vibration thanks to new latching

– Thermal disconnect device for each 

individual connector

– Optical, mechanical status indication for 

the individual arresters

– With or without floating remote 

indication contact

– Mechanical coding of all slots
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

Type 1/2 combination protective device
VALVETRAB MS

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; 

L1, L2, L3, N, PE (3+1 circuit)

5-conductor system; 

L1, L2, L3, N, PE (4+0 circuit)

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

PEN

PEN

L1

L2

L3

12

14

11

FM

12

14

11

FM

N

L

12

14

11 FM

N

/

PEN

L

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Technical data

...335

...175

...335

...175

...335

I / II , T1 / T2

I / II , T1 / T2

I / II , T1 / T2

I / II , T1 / T2

I / II , T1 / T2

240/415

 

V

 

AC

 

(TN-C)

120/208

 

V

 

AC

 

(TN-C)

240

 

V

 

AC

 

(TN-S)

 

/

240

 

V

 

AC

 

(TT)

120

 

V

 

AC

 

(TN-S)

 

/

120

 

V

 

AC

 

(TT)

240

 

V

 

AC

 

(TN-C, TN-S)

 

/

240

 

V

 

AC

 

(TT)

L-PEN

L-PEN

L-N / L-PE / N-PE

L-N / L-PE / N-PE

L-N / L-PEN

335 V AC

175 V AC

335 V AC / 335 V AC / 264 V AC

175 V AC / 175 V AC / 264 V AC

335 V AC

12.5 kA

12.5 kA

12.5 kA / 12.5 kA / 50 kA

12.5 kA / 12.5 kA / 50 kA

12.5 kA

12.5 kA

12.5 kA

12.5 kA / 12.5 kA / 50 kA

12.5 kA / 12.5 kA / 50 kA

12.5 kA

50 kA

50 kA

50 kA

50 kA

50 kA

 1.2 kV

 0.8 kV

 1.2 kV / 

 2 kV / 

 1.7 kV

 0.8 kV / 

 2 kV / 

 1.7 kV

 1.2 kV

 25 ns

 25 ns

 25 ns / 

 100 ns / 

 100 ns

 25 ns / 

 100 ns / 

 100 ns

 25 ns

25 kA

25 kA

25 kA

25 kA

25 kA

160 A (gG)

160 A (gG)

160 A (gG)

160 A (gG)

160 A (gG)

53.4 mm / 99 mm / 77.5 mm

35.6 mm / 99 mm / 77.5 mm

17.5 mm / 99 mm / 77.5 mm

/ 15 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

10 ... 2

10 ... 2

-

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

PDT contact

PDT contact

PDT contact

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

30 ... 14

30 ... 14

-

250 V AC / 30 V DC

250 V AC / 30 V DC

250 V AC / 30 V DC

1.5 A AC / 1 A DC

1.5 A AC / 1 A DC

1 A AC / 1 A DC

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VAL-MS-T1/T2 335/12.5/3+0-FM

2800188

1

VAL-MS-T1/T2 335/12.5/1+1-FM

2800186

1

VAL-MS-T1/T2 335/12.5/1+0-FM

2801042

1

VAL-MS-T1/T2 335/12.5/3+0

2800189

1

VAL-MS-T1/T2 335/12.5/1+1

2800187

1

VAL-MS-T1/T2 335/12.5/1+0

2801041

1

VAL-MS-T1/T2 175/12.5/3+0-FM

2800672

1

VAL-MS-T1/T2 175/12.5/1+1-FM

2800674

1

Accessories

Accessories

Accessories

VAL-MS-T1/T2 335/12.5 ST

2800190

10

VAL-MS-T1/T2 335/12.5 ST

2800190

10

VAL-MS-T1/T2 335/12.5 ST

2800190

10

VAL-MS-T1/T2 175/12.5 ST

2800676

10

VAL-MS-T1/T2 175/12.5 ST

2800676

10

F-MS-T1/T2 50 ST

2800191

10

37

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

H

W

D

4-conductor system; 

L1, L2, L3, PEN

3-conductor system; 

L, N, PE

2-conductor system; 

L, N, PEN

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

12

14

11 FM

N

/

PEN

L

N

L

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

I / II , T1 / T2

I / II , T1 / T2

Nominal voltage U

N

60

 

V

 

AC

 

(TN)

60

 

V

 

AC

 

(TN-S)

Mode of protection

L-N / L-PEN / (L+) - (L-) / (L-) - PE / (L+) - PE

L-N / N-PE / (L+) - (L-) / (L+) - PE

Maximum continuous operating voltage U

C

75 V AC / 100 V DC

75 V AC / 100 V DC

Impulse discharge current I

imp

 (10/350) µs

12.5 kA

12.5 kA

Nominal discharge  current I

n

 (8/20) µs

12.5 kA

12.5 kA

Max. discharge current I

max

 (8/20)µs

30 kA

30 kA

Protection level U

p

 0.4 kV

 0.4 kV

Response time tA

 25 ns

 25 ns

Short-circuit current rating I

SCCR

25 kA

25 kA

Max. backup fuse with branch wiring

160 A (gG)

160 A (gG)

General data

Dimensions W/H/D

17.5 mm / 97 mm / 77.5 mm

35.6 mm / 97 mm / 77.5 mm

IEC connection data

Solid/stranded/AWG

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

UL connection data

AWG

10 ... 2

10 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

UL connection data

AWG

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

Max. operating current

1.5 A AC / 1 A DC (30 V DC)

1.5 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB-MS, 

varistor-based lightning current arrester

with remote indication contact

VAL-MS-T1/T2 48/12.5/1+0-FM

2801240

1

VAL-MS-T1/T2 48/12.5/1+1V-FM

2801533

1

without remote indication contact

VAL-MS-T1/T2 48/12.5/1+0

2801241

1

VAL-MS-T1/T2 48/12.5/1+1V

2801532

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

VAL-MS-T1/T2 48/12.5 ST

2801242

10

VAL-MS-T1/T2 48/12.5 ST

2801242

10

38

PHOENIX CONTACT

– Universal pluggability
– Thermal disconnect device for each 

individual connector

– Optical, mechanical status indication for 

the individual arresters

– With or without floating remote 

indication contact

– Mechanical coding of all slots
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 1/2 combination protective device
VALVETRAB MS

Surge protection and interference suppression filters

Surge protection for the power supply

2-conductor system; 

L, PEN

3-conductor system; 

L, N, PE

phoenixcontact-protection-html.html
background image

12

14

11 FM

N

/

PEN

L

RT

N

G

L

1

2

14

11

F

M

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Electrical data

IEC test classification

I / II , T1 / T2

I / II , T1 / T2

Nominal voltage U

N

- / -48 V DC

60

 

V

 

AC

 

(TN-S) / -48 V DC

Mode of protection

L-PEN / (L+) - (L-) / (L-) - PE / (L+) - PE

L-N / N-PE / (L+) - (L-) / (L+) - PE

Maximum continuous operating voltage U

C

75 V AC / 100 V DC

75 V AC / 100 V DC

Impulse discharge current I

imp

 (10/350) µs

12.5 kA 12.5 kA

12.5 kA

Nominal discharge  current I

n

 (8/20) µs

12.5 kA

12.5 kA

Max. discharge current I

max

 (8/20)µs

30 kA

30 kA

Protection level U

p

 0.4 kV

 0.4 kV

Response time tA

 25 ns

 25 ns

Short-circuit current rating I

SCCR

25 kA

25 kA

Max. backup fuse with branch wiring

160 A AC (gG)

160 A AC (gG)

General data

Dimensions W/H/D

17.5 mm / 77.1 mm / 89.2 mm

70.6 mm / 40.6 mm / 98.1 mm

IEC connection data

Solid/stranded/AWG

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

-

 

mm²

 

/ -

 

mm²

 

/ 15 ... 2

UL connection data

AWG

10 ... 2

10 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

EN 61643-11/A11

-

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

-

 

mm²

 

/ -

 

mm²

 

/ 24 ... 20

UL connection data

AWG

-

-

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

Max. operating current

1.5 A / 1 A (30 V DC)

1.5 A / 1 A (30 V DC)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB MS

with remote indication contact

VAL-MS-T1/T2 48/12.5/O-FM

2906282

12

VAL-MS-T1/T2 48/12.5/1+1/1U/FM

2909629

1

without remote indication contact

VAL-MS-T1/T2 48/12.5/O

2906281

12

Accessories

Accessories

Replacement plug

L-N / L-PEN

VAL-MS-T1/T2 48/12.5 ST

2801242

10

VAL-MS-T1/T2 48/12.5 ST

2801242

10

VALVETRAB,

 base element

VAL-MS-T1/T2 BE/O-FM

2905652

12

VAL-MS BE/1+1/1U/FM

2909628

1

VAL-MS-T1/T2 BE/O

2905650

12

39

PHOENIX CONTACT

– Universal pluggability
– Suitable for 19" applications with 

rackmount systems

– Thermal disconnect device for each 

individual connector

– Optical, mechanical status indication for 

the individual arresters

– With or without floating remote 

indication contact

– Mechanical coding of all slots
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

Type 1/2 combination protective device
VALVETRAB MS

Surge protection and interference suppression filters

Surge protection for the power supply

2-conductor system; 

L, PEN

3-conductor system; 

L, N, PE

phoenixcontact-protection-html.html
background image

12

11

FM

21

22

PE

/

PEN

/

PE

/

PEN

/

12

11

FM

21

22

L1

L2

L3

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

I / II , T1 / T2

I / II , T1 / T2

Nominal voltage U

N

690

 

V

 

AC

 

/

554/960

 

V

 

AC

 

(TN-C)

 

/

690

 

V

 

AC

 

(IT)

690

 

V

 

AC

 

/

554/960

 

V

 

AC

 

(TN-C)

 

/

690

 

V

 

AC

 

(IT)

Mode of protection

L-PE

L-PE

Maximum continuous operating voltage U

C

800 V AC

800 V AC

Impulse discharge current I

imp

 (10/350) µs

35 kA

35 kA

Nominal discharge  current I

n

 (8/20) µs

35 kA

35 kA

Max. discharge current I

max

 (8/20)µs

100 kA

100 kA

Residual voltage at 5 kA

 2.2 kV

 2.2 kV

Protection level U

p

 4.5 kV

 4.5 kV

Response time tA

 100 ns

 100 ns

Short-circuit current rating I

SCCR

50 kA

50 kA

Max. backup fuse with branch wiring

400 A (gG; 2 x 50 mm²)

400 A (gG; 2 x 50 mm²)

General data

Dimensions W/H/D

56 mm / 191 mm / 280 mm

176 mm / 191 mm / 280 mm

IEC connection data

Solid/stranded/AWG

16

 

...

 

50

 

mm²

 

/ 16

 

...

 

50

 

mm²

 

/ 6 ... 1/0

16

 

...

 

50

 

mm²

 

/ 16

 

...

 

50

 

mm²

 

/ 6 ... 1/0

UL connection data

AWG

1/0 ... 6

1/0 ... 6

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

2x N/C contacts, 1-pos.

2x N/C contacts, 1-pos.

IEC connection data

Solid/stranded/AWG

0.2

 

...

 

2.5

 

mm²

 

/ 0.2

 

...

 

2.5

 

mm²

 

/ 24 ... 12

0.2

 

...

 

2.5

 

mm²

 

/ 0.2

 

...

 

2.5

 

mm²

 

/ 24 ... 12

UL connection data

AWG

24 ... 12

24 ... 12

Max. operating voltage

30 V AC / 30 V DC

30 V AC / 30 V DC

Max. operating current

1.5 A AC / 1.5 A DC

1.5 A AC / 1.5 A DC

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

POWERTRAB

PWT 35-800AC-FM

2800419

1

POWERTRAB, 

incl. mounting set

PWT 100-800AC-FM

2800531

1

Accessories

Accessories

Mounting set

 for connecting three lightning current arresters of 

type

 

PWT

 

35-800AC-FM

PWT CCT-SET

2800532

1

Mounting set

 for connecting four lightning current arresters of 

type

 

PWT

 

35-800AC-FM

PWT CCT-SET 4

2905613

1

40

PHOENIX CONTACT

– Series connection from the high-capacity 

varistor and gas-filled surge arrester

– Free of leakage current, suitable for use in 

the pre-meter area

– High TOV resistance for use in IT systems 

and in the event of repetitive current peaks, 
e.g., triggered by frequency inverters

– Satisfies the installation requirements for 

use in wind turbine generators according 
to CLC/TS 50539-22

– Encapsulated die-cast housing for direct 

assembly on mounting plates

– Suitable for use in harsh industrial 

environments

– High lightning impulse current of 35 kA 

per position

– Multi-stage status monitoring via remote 

indication contact

– Visual status indicator on the device

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 1/2 combination protective device
POWERTRAB PWT

Surge protection and interference suppression filters

Surge protection for the power supply

2-conductor system, 

L, PE/PEN

4-conductor system; 

L1, L2, L3, PE/PEN

phoenixcontact-protection-html.html
background image

-/+

+/-

1

2

14

F

M

11

12

14

11 FM

L–

L+

For further information and full technical data, visit phoenixcontact.net/products

 

 

Technical data

Technical data

Electrical data

... 600DC

... 1000DC

... 1500DC

... 600DC

... 1000DC

IEC test classification

PV I / II , T1 / T2

PV I / II , T1 / T2

PV I / II , T1 / T2

PV I / II , T1 / T2

PV I / II , T1 / T2

Mode of protection

(L+) - (L-) / 

(L+) - PE / 

(L-) - PE

(L+) - (L-) / 

(L+) - PE / 

(L-) - PE

(L+) - (L-) / 

(L+) - PE / 

(L-) - PE

(L+) - (L-) / 

(L+) - PE / 

(L-) - PE

(L+) - (L-) / 

(L+) - PE / 

(L-) - PE

Maximum continuous operating voltage U

CPV

800 V DC

1000 V DC

1500 V DC

720 V DC

1050 V DC

Impulse discharge current I

imp

 (10/350) µs

6.25 kA

6.25 kA

6.25 kA

5 kA

5 kA

Nominal discharge  current I

n

 (8/20) µs

20 kA

20 kA

20 kA

15 kA

15 kA

Max. discharge current I

max

 (8/20)µs

40 kA

40 kA

40 kA

40 kA

40 kA

Protection level U

p

 2.9 kV

 3.3 kV

 4.5 kV

 2.6 kV

 3.5 kV

Response time tA

 25 ns

 25 ns

 25 ns

 25 ns

 25 ns

Open circuit voltage U

OCSTC

 667 V DC

 833 V DC

 1250 V DC

 600 V DC

 875 V DC

Short-circuit current rating I

SCPV

2000 A

2000 A

2000 A

1000 A

1000 A

General data

Dimensions W/H/D

71.2 mm / 120 mm / 65.5 mm

53.4 mm / 99 mm / 65.5 mm

IEC connection data

Solid/stranded/AWG

-

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 14 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

EN 50539-11

EN 50539-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

Max. operating voltage

250 V AC / 5 V DC ... 30 V DC

250 V AC / 30 V DC

Max. operating current

1.5 A AC / 5 mA DC ... 1 A DC

1.5 A AC / 1 A DC

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB ...PV

VAL-MB-T1/T2 600DC-PV/2+V-FM

2906292

1

VAL-MS-T1/T2 600DC-PV/2+V-FM

2801164

1

VAL-MB-T1/T2 1000DC-PV/2+V-FM

2905638

1

VAL-MS-T1/T2 1000DC-PV/2+V-FM

2801161

1

VAL-MB-T1/T2 1500DC-PV/2+V-FM

2905640

1

VALVETRAB ...PV,

 without FM contact

VAL-MB-T1/T2 600DC-PV/2+V

2906293

1

VAL-MS-T1/T2 600DC-PV/2+V

2801163

1

VAL-MB-T1/T2 1000DC-PV/2+V

2905639

1

VAL-MS-T1/T2 1000DC-PV/2+V

2801160

1

VAL-MB-T1/T2 1500DC-PV/2+V

2905641

1

Accessories

Accessories

Replacement plug

600

 

V

 

DC

(L+)-PE & (L-)-PE & (L+)-(L-)

VAL-MS-T1/T2 600DC-PV-ST

2801165

1

1000

 

V

 

DC

(L+)-PE & (L-)-PE & (L+)-(L-)

VAL-MS-T1/T2 1000DC-PV-ST

2801162

1

41

PHOENIX CONTACT

– Double terminal block for safe and easy 

equipotential bonding connection

– Screw shafts with raised domes to ensure 

safe working

– Main connections with extended 

insertion funnels for increased resistance 
to creepage

– Optical, mechanical status indication for 

the individual arresters

– Visual display for checking the status 

directly on the device

– Pluggable signal connection for remote 

status signaling

– Compact design for space-saving 

installation

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

new

H

W

D

Type 1/2 combination protective device
VALVETRAB MB / VALVETRAB MS

Surge protection and interference suppression filters

Surge protection for the power supply

One-piece lightning current and surge 

protection for PV applications up to 1500 V DC

Pluggable lightning current and surge 

protection for PV applications up to 1000 V DC

phoenixcontact-protection-html.html
background image

12

14

11 FM

N

PE

L2

L1

L3

12

14

11 FM

PEN

L1

L3

L2

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

I + II , T1 + T2

I + II , T1 + T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-C)

Mode of protection

L-N / L-PE / N-PE

L-PEN

Maximum continuous operating voltage U

C

350 V AC

350 V AC

Impulse discharge current I

imp

 (10/350) µs

25 kA / 25 kA / 100 kA

25 kA

Nominal discharge  current I

n

 (8/20) µs

25 kA / 25 kA / 100 kA

25 kA

Protection level U

p

 1.5 kV / 

 2.2 kV / 

 1.5 kV

 1.5 kV

Follow current interrupt rating I

fi

25 kA (264 V AC) / - / 100 A (350 V AC)

25 kA (264 V AC)

Response time tA

 25 ns / - / 

 100 ns

 25 ns

Short-circuit current rating I

SCCR

25 kA (264 V

 

AC)

25 kA (264 V

 

AC)

Max. backup fuse with branch wiring

315 A (gG)

315 A (gG)

General data

Dimensions W/H/D

142.4 mm / 95.2 mm / 74.5 mm

106.8 mm / 95.2 mm / 74.5 mm

106.8 mm / 95.2 mm / 74.5 mm

71.2 mm / 95.2 mm / 74.5 mm

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

UL connection data

AWG

12 ... 2

12 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

UL connection data

AWG

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 1

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A A

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type 1+2 protective device combination

FLT-SEC-T1+T2-3S-350/25-FM

2905470

1

FLT-SEC-T1+T2-3C-350/25-FM

2905469

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

FLT-SEC-T1-350/25-P

2905471

1

FLT-SEC-T1-350/25-P

2905471

1

L-N / L-PEN

VAL-SEC-T2-350-P

2905346

1

VAL-SEC-T2-350-P

2905346

1

N-PE

FLT-SEC-P-T1-N/PE-350/100-P

2905473

1

42

PHOENIX CONTACT

– Directly coordinated combination of type 

1 spark gap without line follow current 
and type 2 varistor arrester

– Particularly suitable for maximum 

protection of sensitive devices in harsh 
environments

– Pluggable
– High continuous voltage of 350 V AC for 

230/400 V AC networks with high voltage 
fluctuations

– Low voltage protection level of 1.5 kV
– Optical, mechanical status indicator
– With floating remote indication contact
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

Type 1+2 protective device combination
FLASHTRAB SEC T1+T2

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; 

L1, L2, L3, N, PE

4-conductor system; 

L1, L2, L3, PEN

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

12

14

11 FM

N

PE

L2

L1

PEN

L1

L2

12

14

11

FM

12

14

11 FM

N

PE

L

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Technical data

I + II , T1 + T2

I + II , T1 + T2

I + II , T1 + T2

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-C)

240

 

V

 

AC

 

(TN-S)

 

/

240

 

V

 

AC

 

(TT)

L-N / L-PE / N-PE

L-PEN

L-N / L-PE / N-PE

350 V AC

350 V AC

350 V AC

25 kA / 25 kA / 100 kA

25 kA

25 kA / 25 kA / 100 kA

25 kA / 25 kA / 100 kA

25 kA

25 kA / 25 kA / 100 kA

 1.5 kV / 

 2.2 kV / 

 1.5 kV

 1.5 kV

 1.5 kV / 

 2.2 kV / 

 1.5 kV

25 kA (264 V AC) / - / 100 A (350 V AC)

25 kA (264 V

 

AC)

25 kA (264 V AC) / - / 100 A (350 V AC)

 25 ns / - / 

 100 ns

 25 ns

 25 ns / - / 

 100 ns

25 kA (264 V

 

AC)

25 kA (264 V

 

AC)

25 kA (264 V

 

AC)

315 A (gG)

315 A (gG)

315 A (gG)

Dimensions W/H/D

142.4 mm / 95.2 mm / 74.5 mm

106.8 mm / 95.2 mm / 74.5 mm

106.8 mm / 95.2 mm / 74.5 mm

71.2 mm / 95.2 mm / 74.5 mm

71.2 mm / 95.2 mm / 74.5 mm

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

12 ... 2

12 ... 2

12 ... 2

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

PDT contact

PDT contact

PDT contact

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

30 ... 14

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

FLT-SEC-T1+T2-2S-350/25-FM

2905468

1

FLT-SEC-T1+T2-2C-350/25-FM

2905467

1

FLT-SEC-T1+T2-1S-350/25-FM

2905466

1

Accessories

Accessories

Accessories

FLT-SEC-T1-350/25-P

2905471

1

FLT-SEC-T1-350/25-P

2905471

1

FLT-SEC-T1-350/25-P

2905471

1

VAL-SEC-T2-350-P

2905346

1

VAL-SEC-T2-350-P

2905346

1

VAL-SEC-T2-350-P

2905346

1

FLT-SEC-P-T1-N/PE-350/100-P

2905473

1

FLT-SEC-P-T1-N/PE-350/100-P

2905473

1

43

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

H

W

D

4-conductor system; 

L1, L2, N, PE

3-conductor system; 

L1, L2, PEN

3-conductor system; 

L, N, PE

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

PEN

L1

12

14

11

FM

12

14

11 FM

N

PE

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

I + II , T1 + T2

I / II , T1 / T2

Nominal voltage U

N

240

 

V

 

AC

 

(TN-C)

 

/

240

 

V

 

AC

 

(TT)

240

 

V

 

AC

 

(TN - only N-PE)

 

/

240

 

V

 

AC

 

(TT - only N-PE)

Mode of protection

L-PEN

N-PE

Maximum continuous operating voltage U

C

350 V AC

350 V AC

Impulse discharge current I

imp

 (10/350) µs

25 kA

100 kA

Nominal discharge  current I

n

 (8/20) µs

25 kA

100 kA

Protection level U

p

 1.5 kV

 1.5 kV

Follow current interrupt rating I

fi

25 kA (264 V

 

AC)

100 A

Response time tA

 25 ns

 100 ns

Short-circuit current rating I

SCCR

25 kA (264 V

 

AC)

-

Max. backup fuse with branch wiring

315 A (gG)

-

General data

Dimensions W/H/D

35.6 mm / 95.2 mm / 74.5 mm

35.6 mm / 95.2 mm / 74.5 mm

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

2.5

 

...

 

35

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 13 ... 2

UL connection data

AWG

12 ... 2

12 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

UL connection data

AWG

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type 1+2 protective device combination

FLT-SEC-T1+T2-1C-350/25-FM

2905465

1

FLT-SEC-P-T1-N/PE-350/100-FM

2905472

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

FLT-SEC-T1-350/25-P

2905471

1

L-N / L-PEN

VAL-SEC-T2-350-P

2905346

1

N-PE

FLT-SEC-P-T1-N/PE-350/100-P

2905473

1

44

PHOENIX CONTACT

– Directly coordinated combination of type 

1 spark gap without line follow current 
and type 2 varistor arrester

– Particularly suitable for maximum 

protection of sensitive devices in harsh 
environments

– Pluggable
– High continuous voltage of 350 V AC for 

230/400 V AC networks with high voltage 
fluctuations

– Low voltage protection level of 1.5 kV
– Optical, mechanical status indicator
– With floating remote indication contact
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 1+2 protective device combination
FLASHTRAB SEC T1+T2

Surge protection and interference suppression filters

Surge protection for the power supply

2-conductor system; 

L, PEN

N-PE spark gap

phoenixcontact-protection-html.html
background image

12

14

11

FM

N

PE

L1

L2

L3

12

14

11

FM

PEN

L1

L2

L3

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Electrical data

IEC test classification

II , T2

II , T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

400/690

 

V

 

AC

 

(TN-C)

Mode of protection

L-N / L-PE / N-PE

L-PEN

Maximum continuous operating voltage U

C

350 V AC / 350 V AC / 264 V AC

440 V AC

Nominal discharge  current I

n

 (8/20) µs

20 kA / 20 kA / 40 kA

20 kA

Max. discharge current I

max

 (8/20)µs

40 kA / 40 kA / 80 kA

40 kA

Protection level U

p

 1.5 kV / 

 1.9 kV / 

 1.5 kV

 1.9 kV

Response time tA

 25 ns / 

 100 ns / 

 100 ns

 25 ns

Short-circuit current rating I

SCCR

25 kA (in case of 315 A gG backup fuse)

 

/

 

50 kA (in case of 200 A gG backup fuse)

25 kA (in case of 315 A gG backup fuse)

 

/

 

50 kA (in case of 200 A gG backup fuse)

Max. backup fuse with branch wiring

315 A (gG)

315 A (gG)

General data

Dimensions W/H/D

49.2 mm / 97.9 mm / 74.5 mm

37.3 mm / 97.9 mm / 74.5 mm

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB SEC

with remote indication contact

VAL-SEC-T2-3S-350/40-FM

2909635

1

VAL-SEC-T2-3C-440-FM

2909968

1

without remote indication contact

VAL-SEC-T2-3S-350/40

2909637

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

VAL-SEC-T2-350-P

2905346

1

VAL-SEC-T2-440-P

2909969

1

N-PE

VAL-SEC-T2-N/PE-264/40-P

2909636

1

45

PHOENIX CONTACT

– Varistor arrester with a low leakage 

current

– High-performance gas-filled surge 

arrester for N/PE protection

– Version with high nominal discharge 

current of 40 kA in the N-PE path for 
systems with increased safety 
requirements

– Extremely narrow design, just 12 mm per 

position, including for 400/690 V AC 
systems

– Pluggable
– Low voltage protection level of 1.5 kV for 

230/400 V AC systems or 1.9 kV for 
400/690 V AC systems

– Optical, mechanical status indicator
– With floating remote indication contact 

as an option

– Plugs can be checked with CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

new

H

W

D

new

Type 2 surge protective device
VALVETRAB SEC

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; 

L1, L2, L3, N, PE

4-conductor system, 

L1, L2, L3, PE(N)

phoenixcontact-protection-html.html
background image

12

14

11

FM

N

PE

L1

L2

L3

12

14

11

FM

PEN

L1

L2

L3

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

... 350

... 350VF

... 350

... 350VF

IEC test classification

II , T2

II , T2

II , T2

II , T2

II , T2

II , T2

II , T2

II , T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-C)

240/415

 

V

 

AC

 

(TN-C)

240/415

Mode of protection

L-N / L-PE / N-PE

L-N / L-PE / N-PE

L-PEN

L-PEN

L-N / L-PE / N-PE

L-PEN

L-N / L-PE / N-PE

L-N / L-PE / N-PE

Maximum continuous operating voltage U

C

350 V AC / 350 V AC / 264 V AC

350 V AC / 350 V AC / 264 V AC

350 V AC

350 V AC

350 V AC / 350 V AC / 264 V AC

350 V AC

350 V AC / 35

Nominal discharge  current I

n

 (8/20) µs

20 kA

10 kA / 10 kA / 20 kA

20 kA

10 kA

20 kA

20 kA

20 kA

10 kA / 10 kA / 20 kA

Max. discharge current I

max

 (8/20)µs

40 kA

20 kA / 20 kA / 40 kA

40 kA

20 kA

40 kA

40 kA

40 kA

20 kA / 20 kA / 40 kA

Protection level U

p

 1.5 kV / 

 1.9 kV / 

 1.5 kV

 1.5 kV / 

 2.3 kV / 

 1.5 kV

 1.5 kV

 1.5 kV

Response time tA

 25 ns / 

 100 ns / 

 100 ns

 100 ns

 25 ns

 100 ns

Short-circuit current rating I

SCCR

25 kA (in case of 315 A gG 

backup fuse)

 

/

 

50 kA (in case of 200 A gG 

backup fuse)

50 kA

25 kA (in case of 315 A gG 

backup fuse)

 

/

 

50 kA (in case of 200 A gG 

backup fuse)

50 kA

25 kA (in case of 315 A gG backup fuse)

Max. backup fuse with branch wiring

315 A (gG)

200 A (gG)

315 A (gG)

200 A (gG)

315 A (gG)

315 A (gG)

315 A (gG)

200 A (gG)

General data

Dimensions W/H/D

49.2 mm / 97.9 mm / 74.5 mm

37.3 mm / 97.9 mm / 74.5 mm

37.3 mm / 97.9 mm / 74.5 mm

25.4 mm / 97.9 mm / 74.5 mm

25.

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

UL connection data

AWG

14 ... 2 (solid)

14 ... 2 (solid)

14 ... 2 (solid)

14 ... 2 (solid)

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

UL connection data

AWG

30 ... 14

30 ... 14

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 1

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A A

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB SEC

with remote indication contact

VAL-SEC-T2-3S-350-FM

2905340

1

VAL-SEC-T2-3C-350-FM

2905339

1

without remote indication contact

VAL-SEC-T2-3S-350

2905345

1

VAL-SEC-T2-3C-350

2905344

1

VALVETRAB SEC...VF,

 free of leakage current

with remote indication contact

VAL-SEC-T2-3S-350VF-FM

2909590

1

VAL-SEC-T2-3C-350VF-FM

2909591

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

VAL-SEC-T2-350-P

2905346

1

VAL-SEC-T2-350-P

2905346

1

N-PE

VAL-SEC-T2-N/PE-350-P

2905347

1

Free of leakage current

L-N / L-PEN

VAL-SEC-T2-350VF-P

2909596

1

VAL-SEC-T2-350VF-P

2909596

1

46

PHOENIX CONTACT

– Varistor arrester with a low leakage 

current

– High-performance gas-filled surge 

arrester for N/PE protection

– Extremely narrow design, just 12 mm per 

position

– Pluggable
– High continuous voltage of 350 V AC for 

230/400 V AC networks with high voltage 
fluctuations

– Low voltage protection level of 1.5 kV
– VF versions free of leakage current with 

series connection from the varistor and 
gas-filled surge arrester

– Optical, mechanical status indicator
– With floating remote indication contact 

as an option

– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

Type 2 surge protective device
VALVETRAB SEC 350

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; 

L1, L2, L3, N, PE

4-conductor system; 

L1, L2, L3, PEN

H

W

D

new

H

W

D

new

phoenixcontact-protection-html.html
background image

12

14

11

FM

N

PE

L1

L2

12

14

11

FM

PEN

L1

L2

12

14

11

FM

N

PE

L1

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Technical data

... 350

... 350

... 350

... 350VF

IEC test classification

II , T2

II , T2

II , T2

II , T2

II , T2

II , T2

II , T2

II , T2

(TN-C)

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-C)

240

 

V

 

AC

 

(TN-S)

 

/

240

 

V

 

AC

 

(TT)

240

 

V

 

AC

 

(TN-S)

 

/

240

 

V

 

AC

 

(TT)

Mode of protection

L-N / L-PE / N-PE

L-N / L-PE / N-PE

L-PEN

L-PEN

L-N / L-PE / N-PE

L-PEN

L-N / L-PE / N-PE

L-N / L-PE / N-PE

350 V AC / 350 V AC / 264 V AC

350 V AC / 350 V AC / 264 V AC

350 V AC

350 V AC

350 V AC / 350 V AC / 264 V AC

350 V AC

350 V AC / 350 V AC / 264 V AC

350 V AC / 350 V AC / 264 V AC

 (8/20) µs

20 kA

10 kA / 10 kA / 20 kA

20 kA

10 kA

20 kA

20 kA

20 kA

10 kA / 10 kA / 20 kA

 (8/20)µs

40 kA

20 kA / 20 kA / 40 kA

40 kA

20 kA

40 kA

40 kA

40 kA

20 kA / 20 kA / 40 kA

 1.5 kV / 

 1.9 kV / 

 1.5 kV

 1.5 kV

 1.5 kV / 

 1.9 kV / 

 1.5 kV

 1.5 kV / 

 2.3 kV / 

 1.5 kV

 25 ns / 

 100 ns / 

 100 ns

 25 ns

 25 ns / 

 100 ns / 

 100 ns

 100 ns

50 kA

25 kA (in case of 315 A gG backup fuse)

 

/

 

50 kA (in case of 200 A gG backup fuse)

25 kA (in case of 315 A gG backup fuse)

 

/

 

50 kA (in case of 200 A gG backup fuse)

25 kA (in case of 315 A gG 

backup fuse)

 

/

 

50 kA (in case of 200 A gG 

backup fuse)

50 kA

315 A (gG)

200 A (gG)

315 A (gG)

315 A (gG)

315 A (gG)

200 A (gG)

Dimensions W/H/D

49.2 mm / 97.9 mm / 74.5 mm

37.3 mm / 97.9 mm / 74.5 mm

37.3 mm / 97.9 mm / 74.5 mm

25.4 mm / 97.9 mm / 74.5 mm

25.4 mm / 97.9 mm / 74.5 mm

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

UL connection data

AWG

14 ... 2 (solid)

14 ... 2 (solid)

14 ... 2 (solid)

14 ... 2 (solid)

14 ... 2 (solid)

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

PDT contact

PDT contact

PDT contact

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

UL connection data

AWG

30 ... 14

30 ... 14

30 ... 14

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

0 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VAL-SEC-T2-2S-350-FM

2905338

1

VAL-SEC-T2-2C-350-FM

2905337

1

VAL-SEC-T2-1S-350-FM

2905333

1

VAL-SEC-T2-2S-350

2905343

1

VAL-SEC-T2-2C-350

2905342

1

VAL-SEC-T2-1S-350

2905341

1

VAL-SEC-T2-1S-350VF-FM

2909592

1

Accessories

Accessories

Accessories

VAL-SEC-T2-350-P

2905346

1

VAL-SEC-T2-350-P

2905346

1

VAL-SEC-T2-350-P

2905346

1

VAL-SEC-T2-N/PE-350-P

2905347

1

VAL-SEC-T2-N/PE-350-P

2905347

1

VAL-SEC-T2-350VF-P

2909596

1

47

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

H

W

D

new

4-conductor system; 

L1, L2, N, PE

3-conductor system; 

L1, L2, PEN

3-conductor system; L, N, PE

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

12

14

11

FM

N

PE

L1

L2

L3

12

14

11

FM

PEN

L1

L2

L3

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

... 175

... 175

IEC test classification

II , T2

II , T2

Nominal voltage U

N

120/208

 

V

 

AC

 

(TN-S)

 

/

120/208

 

V

 

AC

 

(TT)

120/208

 

V

 

AC

 

(TN-C)

Mode of protection

L-N / L-PE / N-PE

L-PEN

Maximum continuous operating voltage U

C

175 V AC / 175 V AC / 150 V AC

175 V AC

Nominal discharge  current I

n

 (8/20) µs

20 kA

20 kA

Max. discharge current I

max

 (8/20)µs

40 kA

40 kA

Protection level U

p

 0.85 kV / 

 1.3 kV / 

 0.95 kV

 0.85 kV

Response time tA

 25 ns / 

 100 ns / 

 100 ns

 25 ns

Short-circuit current rating I

SCCR

25 kA (in case of 315 A gG backup fuse)

 

/

 

50 kA (in case of 200 A gG backup fuse)

25 kA (in case of 315 A gG backup fuse)

 

/

 

50 kA (in case of 200 A gG backup fuse)

Max. backup fuse with branch wiring

315 A (gG)

315 A (gG)

General data

Dimensions W/H/D

49.2 mm / 97.9 mm / 74.5 mm

37.3 mm / 97.9 mm / 74.5 mm

37.3 mm / 97.9 mm / 74.5 mm

25.4 mm / 97.9 mm / 74.5 mm

25.

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

UL connection data

AWG

14 ... 2 (solid)

14 ... 2 (solid)

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

UL connection data

AWG

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 1

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A A

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB SEC

with remote indication contact

VAL-SEC-T2-3S-175-FM

2905354

1

VAL-SEC-T2-3C-175-FM

2905353

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

VAL-SEC-T2-175-P

2905355

1

VAL-SEC-T2-175-P

2905355

1

N-PE

VAL-SEC-T2-N/PE-175-P

2905356

1

48

PHOENIX CONTACT

– Varistor arrester with a low leakage 

current

– High-performance gas-filled surge 

arrester for N/PE protection

– Extremely narrow design, just 12 mm per 

position

– Pluggable
– High continuous voltage of 175 V AC for 

120/208 V AC networks with high voltage 
fluctuations

– Low voltage protection level of 0.85 kV 

for the L-N mode of protection and 
0.95 kV for the N-PE mode of protection

– Optical, mechanical status indicator
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

Type 2 surge protective device
VALVETRAB SEC 175

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; 

L1, L2, L3, N, PE

4-conductor system; 

L1, L2, L3, PEN

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

12

14

11

FM

N

PE

L1

L2

12

14

11

FM

PEN

L1

L2

12

14

11

FM

N

PE

L1

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Technical data

... 175

... 175

... 175

II , T2

II , T2

II , T2

120/208

 

V

 

AC

 

(TN-S)

 

/

120/208

 

V

 

AC

 

(TT)

120/208

 

V

 

AC

 

(TN-C)

120

 

V

 

AC

 

(TN-S)

 

/

120

 

V

 

AC

 

(TT)

L-N / L-PE / N-PE

L-PEN

L-N / L-PE / N-PE

175 V AC / 175 V AC / 150 V AC

175 V AC

175 V AC / 175 V AC / 150 V AC

20 kA

20 kA

20 kA

40 kA

40 kA

40 kA

 0.85 kV / 

 1.3 kV / 

 0.95 kV

 0.85 kV

 0.85 kV / 

 1.3 kV / 

 0.95 kV

 25 ns / 

 100 ns / 

 100 ns

 25 ns

 25 ns / - / 

 100 ns

25 kA (in case of 315 A gG backup fuse)

 

/

 

50 kA (in case of 200 A gG backup fuse)

25 kA (in case of 315 A gG backup fuse)

 

/

 

50 kA (in case of 200 A gG backup fuse)

25 kA (in case of 315 A gG backup fuse)

 

/

 

50 kA (in case of 200 A gG backup fuse)

315 A (gG)

315 A (gG)

315 A (gG)

Dimensions W/H/D

49.2 mm / 97.9 mm / 74.5 mm

37.3 mm / 97.9 mm / 74.5 mm

37.3 mm / 97.9 mm / 74.5 mm

25.4 mm / 97.9 mm / 74.5 mm

25.4 mm / 97.9 mm / 74.5 mm

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

14 ... 2 (solid)

14 ... 2 (solid)

14 ... 2 (solid)

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

PDT contact

PDT contact

PDT contact

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

30 ... 14

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VAL-SEC-T2-2S-175-FM

2905351

1

VAL-SEC-T2-2C-175-FM

2905350

1

VAL-SEC-T2-1S-175-FM

2905348

1

Accessories

Accessories

Accessories

VAL-SEC-T2-175-P

2905355

1

VAL-SEC-T2-175-P

2905355

1

VAL-SEC-T2-175-P

2905355

1

VAL-SEC-T2-N/PE-175-P

2905356

1

VAL-SEC-T2-N/PE-175-P

2905356

1

49

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

H

W

D

4-conductor system; 

L1, L2, N, PE

3-conductor system; 

L1, L2, PEN

3-conductor system; 

L, N, PE

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

P

E

DC +/-

DC +/-

1

2

14

11

F

M

P

E

DC +/-

DC +/-

1

2

14

11

F

M

Technical data

Technical data

Electrical data

IEC test classification

II , T2

II , T2

Nominal voltage U

N

48 V DC ... 60 V DC

100 V DC ... 120 V DC

200 V DC ... 220 V DC

350 V DC ... 400 V DC

Mode of protection

(DC+) - (DC-) / (DC+/DC-) - PE

(DC+) - (DC-) / (DC+/DC-) - PE

(DC+) - (DC-) / (DC+/DC-) - PE

(DC+) - (DC-) / (DC

Maximum continuous operating voltage U

C

75 V DC

150 V DC

Nominal discharge  current I

n

 (8/20) µs

20 kA

20 kA

Max. discharge current I

max

 (8/20)µs

40 kA

40 kA

Protection level U

p

 0.9 kV / 

 0.5 kV

 1.8 kV / 

 0.85 kV

Response time tA

 25 ns

 25 ns

Short-circuit current rating I

SCCR

0.2 kA (without backup fuse)

 

/

 

6 kA (for 20 A gG/B backup fuse)

0.2 kA (without backup fuse)

 

/

 

6 kA (for 20 A gG/B backup fuse)

Max. backup fuse with branch wiring

20 A (gG / B at I

SCCR

 > 200 A)

20 A (gG / B at I

SCCR

 > 200 A)

20 A (gG / B at I

General data

Dimensions W/H/D

25.4 mm / 97.9 mm / 74.5 mm

25.4 mm / 97.9 mm / 74.5 mm

25.4 mm / 97.9 mm / 74.5 mm

25.4 mm / 97.9 mm / 74.5 mm

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 1

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB SEC

VAL-SEC-T2-2+0-48DC-FM

2907865

1

VAL-SEC-T2-2+0-120DC-FM

2907874

1

Accessories

Accessories

Replacement plug

(DC+/DC-) - PE

VAL-SEC-T2-48DC-P

2907877

1

VAL-SEC-T2-120DC-P

2907878

1

50

PHOENIX CONTACT

– Varistor arrester with a low leakage 

current

– Extremely narrow design, just 12 mm per 

position

– High continuous voltage for linear DC 

current sources with voltage fluctuations

– Pluggable
– Low protection level
– Optical, mechanical status indicator
– With floating remote indication contact
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

Type 2 surge protective device
VALVETRAB SEC DC

Surge protection and interference suppression filters

Surge protection for the power supply

3-conductor system, DC+, DC-, PE

for 48

 

V

 

DC

3-conductor system, DC+, DC-, PE

for 120

 

V

 

DC

H

W

D

new

H

W

D

new

phoenixcontact-protection-html.html
background image

P

E

DC +/-

DC +/-

1

2

14

11

F

M

P

E

DC +/-

DC +/-

1

2

14

11

F

M

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

II , T2

II , T2

48 V DC ... 60 V DC

100 V DC ... 120 V DC

200 V DC ... 220 V DC

350 V DC ... 400 V DC

Mode of protection

(DC+) - (DC-) / (DC+/DC-) - PE

(DC+) - (DC-) / (DC+/DC-) - PE

(DC+) - (DC-) / (DC+/DC-) - PE

(DC+) - (DC-) / (DC+/DC-) - PE

250 V DC

450 V DC

20 kA

20 kA

40 kA

40 kA

 3 kV / 

 1.5 kV

 3 kV / 

 1.5 kV

 25 ns

 25 ns

0.2 kA (without backup fuse)

 

/

 

6 kA (for 20 A gG/B backup fuse)

0.1 kA (without backup fuse)

 

/

 

6 kA (for 20 A gG/B backup fuse)

 > 200 A)

20 A (gG / B at I

SCCR

 > 200 A)

20 A (gG / B at I

SCCR

 > 200 A)

Dimensions W/H/D

25.4 mm / 97.9 mm / 74.5 mm

25.4 mm / 97.9 mm / 74.5 mm

25.4 mm / 97.9 mm / 74.5 mm

25.4 mm / 97.9 mm / 74.5 mm

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

PDT contact

PDT contact

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

 (30 V DC)

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VAL-SEC-T2-2+0-220DC-FM

2907875

1

VAL-SEC-T2-2+0-380DC-FM

2907876

1

Accessories

Accessories

VAL-SEC-T2-220DC-P

2907879

1

VAL-SEC-T2-380DC-P

2907880

1

51

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

3-conductor system, DC+, DC-, PE

for 220

 

V

 

DC

3-conductor system, DC+, DC-, PE

for 380

 

V

 

DC

H

W

D

new

H

W

D

new

phoenixcontact-protection-html.html
background image

12

14

11

FM

N

L1

L2

L3

1

2

14

11

F

M

N

L

1

L

2

L

3

 

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

VAL-MS 230

VAL-MS 320

VAL-MS 320

IEC test classification

II , T2

II , T2

II , T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

Mode of protection

L-N / L-PE / N-PE

L-N / L-PE / N-PE

L-N / L-PE / N-PE

Maximum continuous operating voltage U

C

275 V AC / 275 V AC / 260 V AC

335 V AC / 335 V AC / 260 V AC

335 V AC / 335 V AC / 260 V AC

335 V AC

275 V AC / - / 260 V AC

335 V 

Nominal discharge  current I

n

 (8/20) µs

20 kA

20 kA

20 kA

Max. discharge current I

max

 (8/20)µs

40 kA

40 kA

40 kA

Protection level U

p

 1.35 kV / 

 1.6 kV / 

 1.5 kV

 1.6 kV / 

 1.9 kV / 

 1.5 kV

 1.6 kV / 

 1.9 kV / 

 1.5 kV

Follow current interrupt rating I

fi

- / - / 100 A

- / - / 100 A

- / - / 100 A

Response time tA

 25 ns / 

 100 ns / 

 100 ns

 25 ns / 

 100 ns / 

 100 ns

 25 ns / 

 100 ns / 

 100 ns

Short-circuit current rating I

SCCR

25 kA

25 kA

25 kA

Max. backup fuse with branch wiring

125 A (gG)

125 A (gG)

125 A (gG)

General data

Dimensions W/H/D

71 mm / 99 mm / 65.5 mm

71 mm / 99 mm / 65.5 mm

53.4 mm / 99 mm / 65.5 mm

35.6 mm / 97 mm / 65.5 mm

IEC connection data

Solid/stranded/AWG

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

1.5

UL connection data

AWG

10 ... 2

10 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

UL connection data

AWG

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 30 V DC

250 V AC / 30 V DC

Max. operating current

750 mA AC / 1 A DC

750 mA AC / 1 A DC

Ordering data

Ordering data

Description

U

C

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB,

 multi-position surge protective device combination

without remote indication contact

275 V AC

VAL-MS 230/3+1

2838209

1

with remote indication contact

275 V AC

VAL-MS 230/3+1 FM

2838199

1

without remote indication contact

335 V AC

VAL-MS 320/3+1

2859178

1

with remote indication contact

335 V AC

VAL-MS 320/3+1/FM

2859181

1

VAL-MS 320/3+1/FM-UD

2856689

1

Accessories

Accessories

Replacement plug

1L-N/PE

VAL-MS 230 ST

2798844

10

1L-N/PE

VAL-MS 320 ST

2838843

10

VAL-MS 320-UD ST

2858315

10

N-PE

F-MS 12 ST

2817990

10

F-MS 12 ST

2817990

10

52

PHOENIX CONTACT

– Multi-channel type 2 arrester
– Consistently pluggable type 2 surge 

protective device

– Disconnect device on each individual 

connector

– Optical, mechanical status indication for 

the individual arresters

– With or without floating remote 

indication contact

– Mechanical coding of all slots
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

Type 2 surge protective device
VALVETRAB MS 230 / 320

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; L1, L2, L3, N, PE, 

supply line supply from below

5-conductor system; L1, L2, L3, N, PE, 

supply line supply from above

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

PEN

PEN

L1

L2

L3

12

14

11

FM

12

14

11 FM

N

L1

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

VAL-MS 320

VAL-MS 230

VAL-MS 320

II , T2

II , T2

II , T2

240/415

 

V

 

AC

 

(TN-C)

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

L-PEN

L-N / L-PE / N-PE

L-N / L-PE / N-PE

275 V AC / 275 V AC / 260 V AC

335 V AC / 335 V AC / 260 V AC

335 V AC / 335 V AC / 260 V AC

335 V AC

275 V AC / - / 260 V AC

335 V AC / - / 260 V AC

20 kA

20 kA

20 kA

40 kA

40 kA

40 kA

 1.5 kV

 1.35 kV / 

 1.6 kV / 

 1.5 kV

 1.5 kV / 

 1.8 kV / 

 1.5 kV

-

- / - / 100 A

- / - / 100 A

 25 ns

 25 ns / 

 100 ns / 

 100 ns

 25 ns / 

 100 ns / 

 100 ns

25 kA

25 kA

25 kA

125 A (gG)

125 A (gG)

125 A (gG)

Dimensions W/H/D

71 mm / 99 mm / 65.5 mm

71 mm / 99 mm / 65.5 mm

53.4 mm / 99 mm / 65.5 mm

35.6 mm / 97 mm / 65.5 mm

/ 15 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

10 ... 2

10 ... 2

-40 °C ... 80 °C

-40 °C ... 80 °C

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

PDT contact

PDT contact

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

30 ... 14

30 ... 14

250 V AC / 30 V DC

250 V AC / 30 V DC

1.5 A AC / 1 A DC

1.5 A AC / 1 A DC

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VAL-MS 230/1+1

2804429

1

VAL-MS 230/1+1-FM

2804432

1

VAL-MS 320/3+0

2920230

1

VAL-MS 320/1+1

2804380

1

VAL-MS 320/3+0-FM

2920243

1

VAL-MS 320/1+1-FM

2804393

1

Accessories

Accessories

VAL-MS 230 ST

2798844

10

VAL-MS 320 ST

2838843

10

VAL-MS 320 ST

2838843

10

F-MS 12 ST

2817990

10

53

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

4-conductor system; 

L1, L2, L3, PEN

3-conductor system; 

L, N, PE

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

1

2

14

11 F

M

N

L1

L

2

L

3

P

E

P

E

12

14

11 FM

L

N

/

PEN

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

II , T2

II , T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN)

 

/

240/415

 

V

 

AC

 

(TT)

 

/

230

 

V

 

AC

 

(IT)

Mode of protection

L-N / L-PE / N-PE

L-N / L-PE / L-PEN

Maximum continuous operating voltage U

C

350 V AC / 350 V AC / 260 V AC

350 V AC

Nominal discharge  current I

n

 (8/20) µs

10 kA / 10 kA / 20 kA

10 kA

Max. discharge current I

max

 (8/20)µs

20 kA / 20 kA / 40 kA

20 kA

Protection level U

p

 1.5 kV / 

 2 kV / 

 1.5 kV

 1.5 kV

Follow current interrupt rating I

fi

- / - / 100 A

- / - / -

Response time tA

 100 ns

 100 ns

Short-circuit current rating I

SCCR

25 kA

25 kA

Max. backup fuse with branch wiring

125 A (gG)

125 A (gG)

General data

Dimensions W/H/D

71 mm / 99 mm / 65.5 mm

17.6 mm / 97 mm / 65.5 mm

IEC connection data

Solid/stranded/AWG

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

UL connection data

AWG

10 ... 2

10 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

UL connection data

AWG

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 30 V DC

250 V AC / 30 V DC

Max. operating current

750 mA AC / 1 A DC

1 A AC / 1 A DC

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB MS

with remote indication contact

VAL-MS 350VF/3+1-FM

2858632

1

VAL-MS 350 VF/FM

2856579

1

without remote indication contact

VAL-MS 350 VF/3+1

2858755

1

VAL-MS 350VF

2856582

1

Accessories

Accessories

Replacement plug

1L-N/PE

VAL-MS 350 VF ST

2856595

10

VAL-MS 350 VF ST

2856595

10

N-PE

F-MS 12 ST

2817990

10

54

PHOENIX CONTACT

– DIN-rail-mountable protective devices
– Comprising base element and plug
– Free of leakage current
– Thermal disconnect device for each 

individual connector

– Optical, mechanical status indication for 

the individual arresters

– With or without floating remote 

indication contact

– Mechanical coding of all slots
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 2 surge protective device
VALVETRAB MS 350

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; L1, L2, L3, N, PE

Free of leakage current

2-conductor system; L, N, PEN

Free of leakage current

phoenixcontact-protection-html.html
background image

12

14

11 FM

N

/

PEN

L

12

14

11 FM

N

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

II , T2

II , T2

Nominal voltage U

N

60

 

V

 

AC

 

(TN)

240/415

 

V

 

AC

 

(TN - only N-PE)

 

/

240/415

 

V

 

AC

 

(TT - only N-PE)

Mode of protection

L-PEN

N-PE

Maximum continuous operating voltage U

C

75 V AC / 100 V DC

260 V AC

Nominal discharge  current I

n

 (8/20) µs

15 kA

20 kA

Max. discharge current I

max

 (8/20)µs

40 kA

40 kA

Protection level U

p

 0.55 kV

 1.5 kV

Follow current interrupt rating I

fi

-

100 A (260 V)

Response time tA

 25 ns

 100 ns

Short-circuit current rating I

SCCR

25 kA

-

Max. backup fuse with branch wiring

125 A AC (gG)

-

General data

Dimensions W/H/D

17.6 mm / 97 mm / 65.5 mm

17.6 mm / 97 mm / 65.5 mm

IEC connection data

Solid/stranded/AWG

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

UL connection data

AWG

10 ... 2

10 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

UL connection data

AWG

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 30 V DC

250 V AC / 30 V DC

Max. operating current

1 A AC / 1 A DC

1 A AC / 1 A DC

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB MS

with remote indication contact

VAL-MS 60/FM

2868033

1

F-MS 12/FM

2817974

1

without remote indication contact

VAL-MS 60

2868020

1

F-MS 12

2817987

1

Accessories

Accessories

Replacement plug

1L-N/PE

VAL-MS  60 ST

2807573

10

F-MS 12 ST

2817990

10

55

PHOENIX CONTACT

– Universal pluggability
– Also suitable for industry solutions, e.g., 

in the rail and telecommunications 
sectors

– Thermal disconnect device for each 

individual connector

– Optical, mechanical status indication for 

the individual arresters

– With or without floating remote 

indication contact

– Mechanical coding of all slots
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 2 surge protective device
VALVETRAB MS

Surge protection and interference suppression filters

Surge protection for the power supply

2-conductor system; 

L, N, PEN

N-PE spark gap

phoenixcontact-protection-html.html
background image

12

14

11 FM

L

PEN

PEN

L1

L2

L3

12

14

11

FM

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

II , T2

II , T2

Nominal voltage U

N

400/690

 

V

 

AC

 

(TN-C)

 

/

690

 

V

 

AC

 

(IT)

554/960

 

V

 

AC

 

(TN-C)

 

/

690

 

V

 

AC

 

(IT)

Mode of protection

L-PE / L-PEN

L-PE / L-PEN

Maximum continuous operating voltage U

C

800 V AC

760 V AC

Nominal discharge  current I

n

 (8/20) µs

15 kA

15 kA

Max. discharge current I

max

 (8/20)µs

30 kA

30 kA

Protection level U

p

 5 kV

 2.9 kV

Response time tA

 100 ns

 25 ns

Short-circuit current rating I

SCCR

25 kA

25 kA

Max. backup fuse with branch wiring

100 A (gG)

100 A (gG)

General data

Dimensions W/H/D

35.6 mm / 99 mm / 58 mm

53.4 mm / 99 mm / 65.5 mm

IEC connection data

Solid/stranded/AWG

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

UL connection data

AWG

-

10 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

UL connection data

AWG

-

30 ... 14

Max. operating voltage

250 V AC / 30 V DC

250 V AC / 30 V DC

Max. operating current

1.5 A AC / 1 A DC

1.5 A AC / 1 A DC

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB MS, 

for mounting on NS

 

35

with remote indication contact

VAL-MS 800/30 VF/FM

2805402

1

VAL-MS 750/30/3+0-FM

2920272

1

without remote indication contact

VAL-MS 750/30/3+0

2920269

1

Accessories

Accessories

Replacement plug

1L-N/PE

VAL-MS 750/30-ST

2920256

10

VAL-MS 750/30-ST

2920256

10

N-PE

F-MS 2200/30 ST

2805392

10

56

PHOENIX CONTACT

– For power supplies with higher supply 

voltages

– Universal pluggability
– Thermal disconnect device for each 

individual connector

– Optical, mechanical status indication for 

the individual arresters

– With or without floating remote 

indication contact

– Mechanical coding of all slots
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 2 surge protective device
VALVETRAB MS

Surge protection and interference suppression filters

Surge protection for the power supply

Free of leakage current, for nominal voltages 

up to 690

 

V

 

AC, e.g., rotor protection for wind 

turbine generators

4-conductor system; L1, L2, L3, PEN 

(554/960 V

 

TN-C system)

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

57

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

phoenixcontact-protection-html.html
background image

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

II , T2

II , T2

Nominal voltage U

N

 (IEC)

60

 

V

 

AC

 

(TN)

120/208

 

V

 

AC

 

(TN)

Nominal voltage U

N

 (UL)

60

 

V AC

120

 

V AC

Maximum continuous operating voltage U

C

75 V AC / 100 V DC

150 V AC

Nominal discharge  current I

n

 (8/20) µs

15 kA

20 kA

Max. discharge current I

max

 (8/20)µs

40 kA

40 kA

Protection level U

p

 0.55 kV

 0.9 kV

General data

Dimensions W/H/D

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB

 surge protection plug

VAL-MS  60 ST

2807573

10

VAL-MS 120 ST

2807586

10

Accessories

Accessories

Base element, 

 with RI contact

1+0

VAL-MS BE/FM

2817738

10

VAL-MS BE/FM

2817738

10

orthogonal

1+0

VAL-MS-T1/T2 BE/O-FM

2905652

12

VAL-MS-T1/T2 BE/O-FM

2905652

12

1+1

VAL-MS/1+1-BE/FM

2920531

1

2+0

VAL-MS/2+0-BE/FM

2805321

1

orthogonal

2+0

VAL-MS BE/2+0/1U/FM

2907037

1

3+0

3+1

VAL-MS/3+1-BE/FM

2838898

1

4+0

Base element, 

 without RI contact

1+0

VAL-MS BE

2817741

10

VAL-MS BE

2817741

10

orthogonal

1+0

VAL-MS-T1/T2 BE/O

2905650

12

VAL-MS-T1/T2 BE/O

2905650

12

1+1

VAL-MS/1+1-BE

2920528

1

2+0

VAL-MS/2+0-BE

2804584

1

3+0

3+1

VAL-MS/3+1-BE

2838885

1

58

PHOENIX CONTACT

– Custom surge protection configuration
– Optical, mechanical status indicator of 

the plug

– Disconnect device in the plug
– Base element coding the first time a plug 

is inserted

– Plugs can be checked with 

CHECKMASTER

Notes:

Choose the plug based on technical data.

Choose the base element corresponding to the required circuit 

and remote signaling function:

- TN-C: X+0 - circuit

- TN-S, TT: X+1 - circuit

- IT: Y+0 - circuit

- X = Number of phases

- Y = Number of phases + if required, neutral conductor

The number of plugs required corresponds to the number before 

the “+” in the circuit data, e.g.,

 

3 plugs in a 3+1 circuit

When using a “+1” circuit, the F-MS 12 plug must be used between 

N and PE. See page 63.

Type 2 surge protective device
VALVETRAB MS

Surge protection and interference suppression filters

Surge protection for the power supply

For 24 and 48 V DC

For 120/208 V grounded wye 

and 120 V split-phase systems

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Technical data

II , T2

II , T2

II , T2

240/415

 

V

 

AC

 

(TN)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN)

 

/

240/415

 

V

 

AC

 

(TT)

 

/

230

 

V

 

AC

 

(IT)

230

 

V AC

230

 

V AC

230

 

V AC

275 V AC

275 V AC

385 V AC

20 kA

20 kA

20 kA

40 kA

40 kA

40 kA

 1.35 kV

 1.35 kV

 1.8 kV

Dimensions W/H/D

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VAL-MS 230 ST

2798844

10

VAL-MS 230-UD-ST

2858962

1

VAL-MS 230 IT ST

2807599

10

Accessories

Accessories

Accessories

VAL-MS BE/FM

2817738

10

VAL-MS BE/FM

2817738

10

VAL-MS BE/FM

2817738

10

VAL-MS-T1/T2 BE/O-FM

2905652

12

VAL-MS-T1/T2 BE/O-FM

2905652

12

VAL-MS/1+1-BE/FM

2920531

1

VAL-MS/1+1-BE/FM

2920531

1

VAL-MS/2+0-BE/FM

2805321

1

VAL-MS/2+0-BE/FM

2805321

1

VAL-MS BE/2+0/1U/FM

2907037

1

VAL-MS BE/2+0/1U/FM

2907037

1

VAL-MS/3+0-BE/FM

2881803

1

VAL-MS/3+0-BE/FM

2881803

1

VAL-MS/3+1-BE/FM

2838898

1

VAL-MS/3+1-BE/FM-UD

2858674

1

VAL-MS/3+1-BE/FM

2838898

1

VAL-MS/4+0-BE/FM RN.

2906484

1

VAL-MS/4+0-BE/FM RN.

2906484

1

VAL-MS BE

2817741

10

VAL-MS BE

2817741

10

VAL-MS BE

2817741

10

VAL-MS-T1/T2 BE/O

2905650

12

VAL-MS-T1/T2 BE/O

2905650

12

VAL-MS/1+1-BE

2920528

1

VAL-MS/1+1-BE

2920528

1

VAL-MS/2+0-BE

2804584

1

VAL-MS/2+0-BE

2804584

1

VAL-MS/3+0-BE

2881816

1

VAL-MS/3+0-BE

2881816

1

VAL-MS/3+1-BE

2838885

1

VAL-MS/3+1-BE

2838885

1

59

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

For 240/415 V TN and TT systems, 

as well as high-leg delta systems

For 240/415 V TN and TT systems, 

marking rotated 180°

For 240/415 V TN and TT systems with 

significantly higher voltage fluctuations

phoenixcontact-protection-html.html
background image

 

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

II , T2

II , T2

Nominal voltage U

N

 (IEC)

240/415

 

V

 

AC

 

(TN)

 

/

240/415

 

V

 

AC

 

(TT)

 

/

230

 

V

 

AC

 

(IT)

240/415

 

V

 

AC

 

(TN)

 

/

240/415

 

V

 

AC

 

(TT)

Nominal voltage U

N

 (UL)

230

 

V AC

320

 

V AC

Maximum continuous operating voltage U

C

385 V AC

335 V AC

Nominal discharge  current I

n

 (8/20) µs

20 kA

20 kA

Max. discharge current I

max

 (8/20)µs

40 kA

40 kA

Protection level U

p

 1.8 kV

 1.5 kV

General data

Dimensions W/H/D

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB

 surge protection plug

VAL-MS 230 IT ST

2807599

10

VAL-MS 320 ST

2838843

10

Accessories

Accessories

Base element, 

 with RI contact

1+0

VAL-MS BE/FM

2817738

10

VAL-MS BE/FM

2817738

10

orthogonal

1+0

VAL-MS-T1/T2 BE/O-FM

2905652

12

VAL-MS-T1/T2 BE/O-FM

2905652

12

1+1

VAL-MS/1+1-BE/FM

2920531

1

2+0

VAL-MS/2+0-BE/FM

2805321

1

VAL-MS/2+0-BE/FM

2805321

1

orthogonal

2+0

VAL-MS BE/2+0/1U/FM

2907037

1

VAL-MS BE/2+0/1U/FM

2907037

1

3+0

VAL-MS/3+0-BE/FM

2881803

1

VAL-MS/3+0-BE/FM

2881803

1

3+1

VAL-MS/3+1-BE/FM

2838898

1

4+0

VAL-MS/4+0-BE/FM RN.

2906484

1

VAL-MS/4+0-BE/FM RN.

2906484

1

Base element, 

 without RI contact

1+0

VAL-MS BE

2817741

10

VAL-MS BE

2817741

10

orthogonal

1+0

VAL-MS-T1/T2 BE/O

2905650

12

VAL-MS-T1/T2 BE/O

2905650

12

1+1

VAL-MS/1+1-BE

2920528

1

2+0

VAL-MS/2+0-BE

2804584

1

VAL-MS/2+0-BE

2804584

1

3+0

VAL-MS/3+0-BE

2881816

1

VAL-MS/3+0-BE

2881816

1

3+1

VAL-MS/3+1-BE

2838885

1

60

PHOENIX CONTACT

– Custom surge protection configuration
– Optical, mechanical status indicator of 

the plug

– Disconnect device in the plug
– Base element coding the first time a plug 

is inserted

– Plugs can be checked with 

CHECKMASTER

Notes:

Choose the plug based on technical data.

Choose the base element corresponding to the required circuit 

and remote signaling function:

- TN-C: X+0 - circuit

- TN-S, TT: X+1 - circuit

- IT: Y+0 - circuit

- X = Number of phases

- Y = Number of phases + if required, neutral conductor

The number of plugs required corresponds to the number before 

the “+” in the circuit data, e.g.,

 

3 plugs in a 3+1 circuit

When using a “+1” circuit, the F-MS 12 plug must be used between 

N and PE. See page 63.

Type 2 surge protective device
VALVETRAB MS

Surge protection and interference suppression filters

Surge protection for the power supply

For IT systems with a voltage

of 230

 

V phase-phase

For 240/415 V TN and TT systems 

with higher voltage fluctuations

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Technical data

II , T2

II , T2

II , T2

240/415

 

V

 

AC

 

(TN)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN)

 

/

240/415

 

V

 

AC

 

(TT)

 

/

230

 

V

 

AC

 

(IT)

400/690

 

V

 

AC

 

(TN)

 

/

500

 

V

 

AC

 

(IT)

320

 

V AC

400

 

V AC

500

 

V AC

335 V AC

440 V AC

600 V AC

20 kA

20 kA

15 kA

40 kA

40 kA

30 kA

 1.5 kV

 2.2 kV

 2.7 kV

Dimensions W/H/D

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VAL-MS 320-UD ST

2858315

10

VAL-MS 400 ST

2816399

10

VAL-MS 500 ST

2807609

10

Accessories

Accessories

Accessories

VAL-MS BE/FM

2817738

10

VAL-MS BE/FM

2817738

10

VAL-MS BE/FM

2817738

10

VAL-MS-T1/T2 BE/O-FM

2905652

12

VAL-MS-T1/T2 BE/O-FM

2905652

12

VAL-MS/2+0-BE/FM

2805321

1

VAL-MS BE/2+0/1U/FM

2907037

1

VAL-MS/3+0-BE/FM

2881803

1

VAL-MS/3+0-BE/FM

2881803

1

VAL-MS/3+1-BE/FM-UD

2858674

1

VAL-MS/4+0-BE/FM RN.

2906484

1

VAL-MS/4+0-BE/FM RN.

2906484

1

VAL-MS BE

2817741

10

VAL-MS BE

2817741

10

VAL-MS BE

2817741

10

VAL-MS-T1/T2 BE/O

2905650

12

VAL-MS-T1/T2 BE/O

2905650

12

VAL-MS/2+0-BE

2804584

1

VAL-MS/3+0-BE

2881816

1

VAL-MS/3+0-BE

2881816

1

61

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

For 240/415 V TN and TT systems with higher 

voltage fluctuations, marking rotated 180°

For 240/415 V TN and TT systems with 

significantly higher voltage fluctuations

For 400/690 V TN systems, 400 V IT systems, 

500 V IT systems, with higher voltage 

fluctuations

phoenixcontact-protection-html.html
background image

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

II , T2

II , T2

Nominal voltage U

N

 (IEC)

400/690

 

V

 

AC

 

(TN)

 

/

500

 

V

 

AC

 

(IT)

5 V AC ... 48 V AC

Nominal voltage U

N

 (UL)

400

 

V AC

48

 

V AC

Maximum continuous operating voltage U

C

580 V AC

75 V AC / 100 V DC

Nominal discharge  current I

n

 (8/20) µs

15 kA

10 kA

Max. discharge current I

max

 (8/20)µs

30 kA

20 kA

Protection level U

p

 2.5 kV

 1.4 kV

General data

Dimensions W/H/D

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB

 surge protection plug

VAL-MS 580-ST

2920434

10

VAL-MS 75 VF ST

2805318

10

Accessories

Accessories

Base element, 

 with RI contact

1+0

VAL-MS BE/FM

2817738

10

VAL-MS BE/FM

2817738

10

orthogonal

1+0

VAL-MS-T1/T2 BE/O-FM

2905652

12

VAL-MS-T1/T2 BE/O-FM

2905652

12

1+1

VAL-MS/1+1-BE/FM

2920531

1

2+0

VAL-MS/2+0-BE/FM

2805321

1

orthogonal

2+0

VAL-MS BE/2+0/1U/FM

2907037

1

3+0

VAL-MS/3+0-BE/FM

2881803

1

3+1

4+0

VAL-MS/4+0-BE/FM RN.

2906484

1

Base element, 

 without RI contact

1+0

VAL-MS BE

2817741

10

VAL-MS BE

2817741

10

orthogonal

1+0

VAL-MS-T1/T2 BE/O

2905650

12

VAL-MS-T1/T2 BE/O

2905650

12

1+1

VAL-MS/1+1-BE

2920528

1

2+0

VAL-MS/2+0-BE

2804584

1

3+0

VAL-MS/3+0-BE

2881816

1

3+1

62

PHOENIX CONTACT

– Custom surge protection configuration
– Optical, mechanical status indicator of 

the plug

– Disconnect device in the plug
– Base element coding the first time a plug 

is inserted

– Plugs can be checked with 

CHECKMASTER

Notes:

Choose the plug based on technical data.

Choose the base element corresponding to the required circuit 

and remote signaling function:

- TN-C: X+0 - circuit

- TN-S, TT: X+1 - circuit

- IT: Y+0 - circuit

- X = Number of phases

- Y = Number of phases + if required, neutral conductor

The number of plugs required corresponds to the number before 

the “+” in the circuit data, e.g.,

 

3 plugs in a 3+1 circuit

When using a “+1” circuit, the F-MS 12 plug must be used between 

N and PE. See page 63.

Type 2 surge protective device
VALVETRAB MS

Surge protection and interference suppression filters

Surge protection for the power supply

For 400/690 V TN systems, 400 V IT systems, 

500 V IT systems, 480 V delta systems

For 24

 

V

 

DC, 48

 

V

 

DC with isolation 

monitoring, free of leakage current

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Technical data

II , T2

II , T2

II , T2

240/415

 

V

 

AC

 

(TN)

 

/

240/415

 

V

 

AC

 

(TT)

 

/

230

 

V

 

AC

 

(IT)

240/415

 

V

 

AC

 

(TN - only N-PE)

 

/

240/415

 

V

 

AC

 

(TT - only N-PE)

240/415

 

V

 

AC

 

(TN - only N-PE)

 

/

240/415

 

V

 

AC

 

(TT - only N-PE)

350

 

V AC

-

 

V AC

-

 

V AC

350 V AC

260 V AC

260 V AC

10 kA

20 kA

20 kA

20 kA

40 kA

40 kA

 1.5 kV

 1.5 kV

 1.5 kV

Dimensions W/H/D

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

17.5 mm / 52.4 mm / 55.3 mm

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VAL-MS 350 VF ST

2856595

10

F-MS 12 ST

2817990

10

F-MS 12-UD ST

2858328

10

Accessories

Accessories

Accessories

VAL-MS BE/FM

2817738

10

VAL-MS BE/FM

2817738

10

VAL-MS BE/FM

2817738

10

VAL-MS-T1/T2 BE/O-FM

2905652

12

VAL-MS-T1/T2 BE/O-FM

2905652

12

VAL-MS/1+1-BE/FM

2920531

1

VAL-MS/1+1-BE/FM

2920531

1

VAL-MS/2+0-BE/FM

2805321

1

VAL-MS BE/2+0/1U/FM

2907037

1

VAL-MS/3+0-BE/FM

2881803

1

VAL-MS/3+1-BE/FM

2838898

1

VAL-MS/3+1-BE/FM

2838898

1

VAL-MS/3+1-BE/FM-UD

2858674

1

VAL-MS/4+0-BE/FM RN.

2906484

1

VAL-MS BE

2817741

10

VAL-MS BE

2817741

10

VAL-MS BE

2817741

10

VAL-MS-T1/T2 BE/O

2905650

12

VAL-MS-T1/T2 BE/O

2905650

12

VAL-MS/1+1-BE

2920528

1

VAL-MS/1+1-BE

2920528

1

VAL-MS/2+0-BE

2804584

1

VAL-MS/3+0-BE

2881816

1

VAL-MS/3+1-BE

2838885

1

VAL-MS/3+1-BE

2838885

1

63

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

For 240/415 V TN and TT systems with 

significantly higher voltage fluctuations, 

free of leakage current

For 240/415 V TN and TT systems on a spark 

gap basis, can only be used for N-PE

For 240/415 V TN and TT systems on a spark 

gap basis, can only be used for N-PE,

marking rotated 180°

phoenixcontact-protection-html.html
background image

-/+

+/-

1

2

14

F

M

11

Technical data

Electrical data

IEC test classification

PV II , T2

Mode of protection

(L+) - (L-) / (L+) - PE / (L-) - PE

Maximum continuous operating voltage U

CPV

1500 V DC

Nominal discharge  current I

n

 (8/20) µs

20 kA

Max. discharge current I

max

 (8/20)µs

40 kA

Protection level U

p

 4.5 kV

Response time tA

 25 ns

Open circuit voltage U

OCSTC

 1250 V DC

Short-circuit current rating I

SCPV

2000 A

General data

Dimensions W/H/D

71.2 mm / 120 mm / 65.5 mm

IEC connection data

Solid/stranded/AWG

-

 

mm²

 

/ 2.5

 

...

 

35

 

mm²

 

/ 14 ... 2

Temperature range

-40 °C ... 80 °C

Test standards

EN 50539-11

Remote indication contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

Max. operating voltage

250 V AC / 5 V DC ... 30 V DC

Max. operating current

1.5 A AC / 5 mA DC ... 1 A DC

Ordering data

Description

Type

Order No.

Pcs./Pkt.

VALVETRAB MB...PV

with remote indication contact

VAL-MB-T2 1500DC-PV/2+V-FM

2905646

1

without remote indication contact

VAL-MB-T2 1500DC-PV/2+V

2905647

1

64

PHOENIX CONTACT

– Double terminal block for safe and easy 

equipotential bonding connection

– Screw shafts with raised domes to ensure 

safe working

– Main connections with extended 

insertion funnels for increased resistance 
to creepage

– Optical, mechanical status indication for 

the individual arresters

– Visual display for checking the status 

directly on the device

– Pluggable signal connection for remote 

status signaling

– Compact design for space-saving 

installation

new

Type 2 surge protective device
VALVETRAB MB

Surge protection and interference suppression filters

Surge protection for the power supply

One-piece surge protection for 

PV applications up to 1500

 

V

 

DC

phoenixcontact-protection-html.html
background image

12

14

11 FM

L–

L+

1

2

14

11 F

M

P

E

L-

L+

L+

L+

For further information and full technical data, visit phoenixcontact.net/products

 

 

Technical data

Technical data

Electrical data

... 1000DC

... 600DC

... 1000DC

IEC test classification

PV II , T2

PV II , T2

PV II , T2

Mode of protection

(L+) - (L-) / (L+) - PE / (L-) - PE

(L+) - (L-) / (L+) - PE / (L-) - PE

(L+) - (L-) / (L+) - PE / (L-) - PE

Maximum continuous operating voltage U

CPV

1170 V DC

800 V DC

1170 V DC

Max. discharge current I

max

 (8/20)µs

40 kA

40 kA

40 kA

Protection level U

p

 3.7 kV

 2.7 kV

 3.8 kV

Response time tA

 25 ns

 25 ns

 25 ns

Open circuit voltage U

OCSTC

 970 V DC

 670 V DC

 970 V DC

Short-circuit current rating I

SCPV

1000 A

1000 A

1000 A

General data

Dimensions W/H/D

53.4 mm / 99 mm / 65.5 mm

89 mm / 98.57 mm / 64.7 mm

IEC connection data

Solid/stranded/AWG

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

1.5

 

...

 

35

 

mm²

 

/ 1.5

 

...

 

25

 

mm²

 

/ 15 ... 2

UL connection data

AWG

10 ... 2

10 ... 2

Temperature range

-40 °C ... 80 °C

-40 °C ... 85 °C

Test standards

EN 50539-11

EN 50539-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

UL connection data

AWG

30 ... 14

30 ... 14

Max. operating voltage

250 V AC / 30 V DC

125 V AC / 30 V DC

Max. operating current

1.5 A AC / 1 A DC

3 A AC / 3 A DC

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB MS...PV

with remote indication contact

VAL-MS 1000DC-PV/2+V-FM

2800627

1

VAL-MS-CN 1000DC-PV/4+V-FM

2907820

1

without remote indication contact

VAL-MS 1000DC-PV/2+V

2800628

1

with remote indication contact

VAL-MS 600DC-PV/2+V-FM

2800641

1

without remote indication contact

VAL-MS 600DC-PV/2+V

2800642

1

Accessories

Accessories

Replacement plug

1000 V DC

VAL-MS 1000DC-PV-ST

2800624

1

600 V DC

VAL-MS 600DC-PV-ST

2800623

1

VAL-MS 4+V/BE/FM

2908725

1

65

PHOENIX CONTACT

– Consistently pluggable type 2 surge 

protective device

– For insulated and single-sided grounded 

PV applications

– Reliable contact, thanks to integrated 

rotating latch

– Optical, mechanical status indication for 

the individual arresters

– With or without floating remote 

indication contact

– Mechanical coding of all slots
– Plugs can be checked with 

CHECKMASTER

H

W

D

new

Type 2 surge protective device
VALVETRAB MS

Surge protection and interference suppression filters

Surge protection for the power supply

Pluggable surge protection,

for PV applications up to 

1000

 

V

 

DC, 1 MPP tracker

Pluggable surge protection,

for PV applications up to 1000

 

V

 

DC,

3 MPP trackers

phoenixcontact-protection-html.html
background image

IN

L1

L2

L3

N

PE

14

12

11 FM

IN

L1

L2

L3

PE

14

12

11 FM

 

 

 

 

 

 

Technical data

Technical data

Electrical data

... 3S-350

... 1S-350

... 3C-350

IEC test classification

II , T2

II , T2

II , T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240

 

V

 

AC

 

(TN-S)

 

/

240

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-C)

Mode of protection

L-N / L-PE / N-PE

L-N / L-PE / N-PE

L-PEN

Maximum continuous operating voltage U

C

350 V AC / 350 V AC / 264 V AC

350 V AC / 350 V AC / 264 V AC

350 V AC

Nominal discharge  current I

n

 (8/20) µs

20 kA

20 kA

20 kA

Max. discharge current I

max

 (8/20)µs

30 kA

30 kA

30 kA

Protection level U

p

 2.5 kV / - / 

 1.7 kV

 2.5 kV / - / 

 1.7 kV

 2.5 kV

Follow current interrupt rating I

fi

- / - / 100 A

- / - / 100 A

-

Response time tA

 25 ns / 

 100 ns / 

 100 ns

 25 ns / 

 100 ns / 

 100 ns

 25 ns

Short-circuit current rating I

SCCR

25 kA

25 kA

25 kA

General data

Dimensions W/H/D

131.5 mm / 101 mm / 76 mm

114 mm / 101 mm / 76 mm

IEC connection data

Solid/stranded/AWG

4

 

...

 

35

 

mm²

 

/ 4

 

...

 

25

 

mm²

 

/ 18 ... 2

4

 

...

 

35

 

mm²

 

/ 4

 

...

 

25

 

mm²

 

/ 18 ... 2

Temperature range

-25 °C ... 60 °C

-25 °C ... 60 °C

Test standards

IEC 61643-11 / EN 61643-11 / IEC 60364-4-443 /

IEC 61643-11 / EN 61643-11 / IEC 60364-4-443 /

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

Max. operating voltage

250 V AC / 250 V DC

250 V AC / 250 V DC

Max. operating current

2 A AC / 1 mA DC ... 50 mA DC

2 A AC / 1 mA DC ... 50 mA DC

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB compact, 

with an arrester backup fuse

3-phase

VAL-CP-MCB-3S-350/40/FM

2882750

1

VAL-CP-MCB-3C-350/40/FM

2882776

1

1-phase

VAL-CP-MCB-1S-350/40/FM

2882763

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

VAL-CP-350-ST-GY

2882718

10

VAL-CP-350-ST-GY

2882718

10

N-PE

VAL-CP-N/PE-350-ST-GY

2882734

10

66

PHOENIX CONTACT

– Combinations of type 2 arresters with 

integrated arrester backup fuse

– Overload of the surge protection results 

in all-pos. disconnection from the mains

– Signaling to monitoring systems via 

remote indication contact in the event of 
an error

– Surge-proof arrester backup fuse tailored 

to type 2 arresters

– Consistently pluggable type 2 surge 

protective device

– Disconnect device on each individual 

connector

– Optical, mechanical status indication for 

all protective plugs

– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 2 surge protective device
VALVETRAB combi MCB

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; L1, L2, L3, N, PE

With integrated backup fuse

4-conductor system; L1, L2, L3, PEN

With integrated backup fuse

phoenixcontact-protection-html.html
background image

PE

N

N

T

1

2

3

4

5

6

PE

N

N

T

1

2

3

4

5

6

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification

II , T2

II , T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

Mode of protection

L-N / L-PE / N-PE

L-N / L-PE / N-PE

Maximum continuous operating voltage U

C

350 V AC / - / 264 V AC

350 V AC / - / 264 V AC

Nominal discharge  current I

n

 (8/20) µs

20 kA

20 kA

Max. discharge current I

max

 (8/20)µs

30 kA

30 kA

Protection level U

p

 2 kV / - / 

 2 kV

 2 kV / - / 

 2 kV

Follow current interrupt rating I

fi

- / - / 100 A (264 V AC)

- / - / 100 A (264 V AC)

Response time tA

 25 ns / - / 

 100 ns

 25 ns / - / 

 100 ns

Short-circuit current rating I

SCCR

10 kA

10 kA

Max. backup fuse with branch wiring

63 A AC (MCB)

63 A (MCB)

General data

Dimensions W/H/D

121 mm / 90 mm / 76 mm

121 mm / 90 mm / 76 mm

IEC connection data

Solid/stranded/AWG

4

 

...

 

25

 

mm²

 

/ 4

 

...

 

25

 

mm²

 

/ 12 ... 4

4

 

...

 

25

 

mm²

 

/ 4

 

...

 

25

 

mm²

 

/ 12 ... 4

Temperature range

-25 °C ... 40 °C

-25 °C ... 40 °C

Test standards

IEC 61643-11 / EN 61643-11 / EN 61008-1 /

IEC 61643-11 / EN 61643-11 / EN 61008-1 /

IEC

 

60947-1 / IEC

 

60947-3

IEC

 

60947-1 / IEC

 

60947-3

RCD data

Tripping characteristic

A (selective)

A (si type)

Nominal load current I

L

40 A

40 A

Rated residual operating current I

Δ

n

300 mA

30 mA

Rated making and breaking capacity I

m

1.5 kA

1.5 kA

Rated residual making and breaking capacity I

Δ

m

2.5 kA

2.5 kA

Rated impulse withstand voltage U

imp

6 kV (1.2/50 µs)

6 kV (1.2/50 µs)

Rated conditional short-circuit current I

nc

10 kA

10 kA

Tripping time for I

Δ

n

 300 ms

 300 ms

Tripping time for 5xI

Δ

n

 40 ms

 40 ms

Switching cycles, max.

20000

20000

Utilization category

AC 23 A

AC 23 A

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB compact with RCD

VAL-CP-RCD-3S/40/0.3/SEL

2808001

1

VAL-CP-RCD-3S/40/0.03

2882802

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

VAL-CP-350-ST-GY

2882718

10

VAL-CP-350-ST-GY

2882718

10

N-PE

VAL-CP-N/PE-350-ST-GY

2882734

10

VAL-CP-N/PE-350-ST-GY

2882734

10

67

PHOENIX CONTACT

– Combination of type 2 surge protective 

device and RCD residual current circuit 
breaker

– Personal protection and surge protection 

in one device

– Consistently pluggable type 2 surge 

protective device

– Disconnect device on each individual 

connector

– Optical, mechanical status indication for 

all protective plugs

– Residual current circuit breaker is not 

triggered by magnetic influences caused 
by discharge currents in the type 2 
arrester

– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 2 surge protective device
VALVETRAB combi RCD

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; L1, L2, L3, N, PE

With selective RCD residual current circuit 

breaker,

 

300

 

mA

5-conductor system; L1, L2, L3, N, PE

With selective RCD residual current circuit 

breaker,

 

30

 

mA

phoenixcontact-protection-html.html
background image

12

14

11 FM

L1

L2

L3

N

PE

12

14

11 FM

L1

L2

L3

PEN

Technical data

Technical data

Electrical data

IEC test classification

II , T2

II , T2

Nominal voltage U

N

240/415

 

V

 

AC

 

(TN-S)

 

/

240/415

 

V

 

AC

 

(TT)

240/415

 

V

 

AC

 

(TN-C)

 

/

240/415

 

V

 

AC

 

(TT)

Mode of protection

L-N / L-PE / N-PE

L-PEN

Maximum continuous operating voltage U

C

350 V AC / 350 V AC / 264 V AC

350 V AC

Nominal discharge  current I

n

 (8/20) µs

20 kA

20 kA

Max. discharge current I

max

 (8/20)µs

25 kA / 25 kA / 40 kA

25 kA

Protection level U

p

 2.5 kV / - / 

 1.5 kV

 2.5 kV

Response time tA

 25 ns / 

 100 ns / 

 100 ns

 25 ns

Short-circuit current rating I

SCCR

25 kA

25 kA

General data

Dimensions W/H/D

54 mm / 220 mm / 134 mm

54 mm / 220 mm / 134 mm

IEC connection data

Solid/stranded/AWG

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

2.5

 

...

 

25

 

mm²

 

/ 2.5

 

...

 

16

 

mm²

 

/ 12 ... 4

Temperature range

-25 °C ... 55 °C

-25 °C ... 55 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

PDT contact

IEC connection data

Solid/stranded/AWG

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

0.14

 

...

 

1.5

 

mm²

 

/ 0.14

 

...

 

1.5

 

mm²

 

/ 28 ... 16

Max. operating voltage

250 V AC / 125 V DC (200 mA DC)

250 V AC / 125 V DC (200 mA DC)

Max. operating current

1 A AC / 1 A DC (30 V DC)

1 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

VALVETRAB compact

VAL-CP-MOSO 60-3S-FM

2804403

1

VAL-CP-MOSO 60-3C-FM

2804416

1

Accessories

Accessories

Replacement plug

L-N / L-PEN

VAL-CP-350-ST-GY

2882718

10

VAL-CP-350-ST-GY

2882718

10

N-PE

VAL-CP-N/PE-350-ST-GY

2882734

10

68

PHOENIX CONTACT

– Combinations of type 2 arresters with 

integrated arrester backup fuse

– For 60 mm system technology
– Tool-free mounting on 5 and 10 mm 

busbars

– Signaling to monitoring systems via 

remote indication contact in the event of 
an error

– Surge-proof arrester backup fuse tailored 

to type 2 arresters

– Consistently pluggable type 2 surge 

protective device

– Disconnect device on each individual 

connector

– Optical, mechanical status indication for 

all protective plugs

– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 2 surge protective device
VALVETRAB combi MCB

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; L1, L2, L3, N, PE

For 60

 

mm system technology

4-conductor system; L1, L2, L3, PEN

For 60

 

mm system technology

phoenixcontact-protection-html.html
background image

N

L'

L

P

E

N

L'

L

For further information and full technical data, visit phoenixcontact.net/products

 

 

Technical data

Technical data

Electrical data

IEC test classification

II / III , T2 / T3

II / III , T2 / T3

Nominal voltage U

N

100 V AC ... 277 V AC (TN-S)

 

/

 

100 V AC ... 277 V AC (TT)

100 V AC ... 277 V AC

Mode of protection

L-N / L-PE / N-PE

L-N

Maximum continuous operating voltage U

C

320 V AC / 305 V AC / 305 V AC

320 V AC

Combination wave U

OC

L-N / N-PE

10 kV

10 kV

Nominal discharge  current I

n

 (8/20) µs

5 kA / 5 kA / 10 kA

5 kA

Max. discharge current I

max

 (8/20)µs

10 kA / 10 kA / 20 kA

10 kA

Protection level U

p

 1.3 kV / 

 1.5 kV / 

 1.4 kV

 1.3 kV

Response time tA

 25 ns / - / 

 100 ns

 25 ns

Max. backup fuse with branch wiring

16 A (MCB B/C)

16 A (MCB B/C)

General data

Dimensions W/H/D

36.5 mm / 56 mm / 34 mm

36.5 mm / 56 mm / 34 mm

IEC connection data

Solid/stranded/AWG

0.2

 

...

 

4

 

mm²

 

/ 0.2

 

...

 

2.5

 

mm²

 

/ -

0.2

 

...

 

4

 

mm²

 

/ 0.2

 

...

 

2.5

 

mm²

 

/ -

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

BLOCKTRAB,

 for universal mounting

BLT-T2-1S-320-UT

2906101

10

BLT-T2-320-UT

2906100

10

69

PHOENIX CONTACT

– Universal use for street, tunnel or object 

lighting

– Flexible installation
– Fixed via integrated elongated holes
– Compact  design
– Optical, mechanical status indicator
– Connection in branch or through wiring
– Double or reinforced insulation

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 2 surge protective device for 
LED applications

Surge protection and interference suppression filters

Surge protection for the power supply

For insulation class I

For insulation class II

phoenixcontact-protection-html.html
background image

L/

N

N

/L

P

E

L/

N

Alarm

N

/L

P

E

Technical data

Technical data

Electrical data

IEC test classification

II , T2

II , T2

Nominal voltage U

N

230

 

V

 

AC

 

(TN)

 

/

230

 

V

 

AC

 

(TT)

230

 

V

 

AC

 

(TN)

 

/

230

 

V

 

AC

 

(TT)

Mode of protection

L-N / L-PE / N-PE

L-N / L-PE / N-PE

Maximum continuous operating voltage U

C

350 V AC

350 V AC

Nominal discharge  current I

n

 (8/20) µs

5 kA

20 kA

Protection level U

p

 1.5 kV

 2.5 kV / 

 1.8 kV / 

 1.8 kV

Response time tA

 25 ns / 

 100 ns / 

 100 ns

 25 ns / 

 100 ns / 

 100 ns

Short-circuit current rating I

SCCR

1 kA

1 kA

Max. backup fuse with branch wiring

16 A (MCB C)

63 A (MCB C)

General data

Dimensions W/H/D

24 mm / 15.7 mm / 25.3 mm

38.4 mm / 41 mm / 22.4 mm

Conductive path width

 12 mm (2 OZ) / 

 8 mm (3 OZ)

 28 mm (2 OZ) / 

 19 mm (3 OZ)

Temperature range

-40 °C ... 70 °C

-40 °C ... 85 °C

Test standards

IEC 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

N/C contact

Max. operating voltage

- / -

250 V AC / 30 V DC

Max. operating current

- / -

1 A AC / 1 A DC

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PRINTRAB

PRT-1S-350/5S

2908551

1

PRT-1S-350/20/R

2905977

1

70

PHOENIX CONTACT

– Powerful type 2 surge protection
– Can be soldered directly onto the 

printed-circuit board

– Very small footprint
– Low height matching standard PCB 

components

– Optionally available with remote 

indication contact or visual status 
indicator

– Safe mechanical disconnection in the 

event of an overload

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

new

new

Type 2 surge protective device
For PCB mounting

Surge protection and interference suppression filters

Surge protection for the power supply

3-conductor system; L, N, PE

with visual status indicator

3-conductor system; L, N, PE

with remote indication contact

phoenixcontact-protection-html.html
background image

5

L1

7

L

2

9

L

3

6

8
10

I

N

OUT

2

N

4

3

P

E

N

L

1

L

2

L

3

1

11

1

2

6

5

L

2

1

N

4

3

P

E

I

N

11

1

2

OUT

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

Ex: 

Technical data

Technical data

Electrical data

... 230

... 24

... 60

... 120

... 230

IEC test classification

III / T3

III / T3

III / T3

III / T3

III / T3

Nominal voltage U

N

230 V AC

24 V AC

60 V AC

120 V AC

230 V AC

Mode of protection

L-N / L-PE / N-PE

L-N / L-PE / 

N-PE / 

(L+) - (L-) / 

(L+/L-) - PE

L-N / L-PE / 

N-PE / 

(L+) - (L-) / 

(L+/L-) - PE

L-N / L-PE / 

N-PE / 

(L+) - (L-) / 

(L+/L-) - PE

L-N / L-PE / 

N-PE / 

(L+) - (L-) / 

(L+/L-) - PE

Maximum continuous operating voltage U

C

AC/DC

264 V AC / -

34 V AC / 

34 V DC

100 V AC / 

80 V DC

150 V AC / 

150 V DC

264 V AC / 

230 V DC

Rated load current I

L

26 A (30 °C)

26 A (30 °C)

26 A (30 °C)

26 A (30 °C)

26 A (30 °C)

Nominal discharge current I

n

 (8/20) µs

3 kA

1 kA

2 kA

3 kA

3 kA

Combined surge U

OC

6 kV

2 kV

4 kV

6 kV

6 kV

Protection level U

p

L-N / L(N)-PE

 1.4 kV / 

 1.5 kV

 0.25 kV / 

 0.65 kV

 0.48 kV / 

 0.9 kV

 0.85 kV / 

 0.95 kV

 1.35 kV / 

 1.5 kV

Response time t

A

L-N / L(N)-PE

 25 ns / 

 100 ns

 25 ns / 

 100 ns

 25 ns / 

 100 ns

 25 ns / 

 100 ns

 25 ns / 

 100 ns

Short-circuit current rating I

SCCR

1.5 kA AC

1.5 kA AC / 

1 kA DC

1.5 kA AC / 

1 kA DC

1.5 kA AC / 

0.25 kA DC

1.5 kA AC / 

0.25 kA DC

Max. backup fuse with branch wiring

not required

not required

General data

Dimensions W/H/D

35.4 mm / 90 mm / 74.5 mm

17.7 mm / 90 mm / 74.5 mm

IEC connection data

Solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 70 °C

-40 °C ... 80 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

N/C contact

N/C contact

IEC connection data

Solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Max. operating voltage

250 V AC / 125 V DC

250 V AC / 125 V DC

Max. operating current

3 A AC / 1 A DC (30 V DC)

3 A AC / 1 A DC (30 V DC)

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

MAINS-PLUGTRAB, 

consisting of a plug and base element

24 V AC

PLT-SEC-T3-24-FM

2905223

1

60 V AC

PLT-SEC-T3-60-FM

2905225

1

120 V AC

PLT-SEC-T3-120-FM

2905228

1

230 V AC

PLT-SEC-T3-3S-230-FM

2905230

1

PLT-SEC-T3-230-FM

2905229

1

Accessories

Accessories

Replacement plug

24 V AC

PLT-SEC-T3-24-P

2905232

1

60 V AC

PLT-SEC-T3-60-P

2905233

1

120 V AC

PLT-SEC-T3-120-P

2905234

1

230 V AC

PLT-SEC-T3-3S-230-P

2905236

1

PLT-SEC-T3-230-P

2905235

1

PLUGTRAB base element,

 for mounting on NS

 

35

PLT-SEC-T3-BE

2905557

1

71

PHOENIX CONTACT

– Varistor-based device protection
– For single and three-phase power supply 

units

– Pluggable
– Through wiring
– Can be used without separate backup 

fuse thanks to integrated overcurrent 
protection

– Optical status indicator via LED
– With floating remote indication contact
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 3 device protection
PLUGTRAB SEC

Surge protection and interference suppression filters

Surge protection for the power supply

5-conductor system; 

L1, L2, L3, N, PE

3-conductor system; 

L, N, PE

phoenixcontact-protection-html.html
background image

IN

OUT

1

2

3

4

5

6

12

11

+

-

~

~

(+)

(-)

I

N

OUT

5

6

3

4

1

2

11

1

2

P

E

P

E

J

 

Technical data

Technical data

Electrical data

IEC test classification

III / T3

III / T3

Nominal voltage U

N

- / 48 V DC

230 V AC

Mode of protection

L-N / L-PE / N-PE / (L+) - (L-) / (L+/L-) - PE

L-L / L-PE

Maximum continuous operating voltage U

C

AC/DC

- / 60 V DC

- / -

Maximum continuous operating voltage U

C

L-N / L-PE

- / -

275 V AC / 440 V AC

Rated load current I

L

26 A (30 °C)

16 A (60°C)

Nominal discharge current I

n

 (8/20) µs

500 A

3 kA

Combined surge U

OC

1 kV (2 

) / 6 kV (12 

)

6  kV

Protection level U

p

 120 V

-

Protection level U

p

L-N / L(N)-PE

- / -

 1.2 kV / 

 1.5 kV

Response time t

A

L-N / L(N)-PE

 1 ns / 

 1 ns

 25 ns / 

 100 ns

Backup fuse max. in acc. with IEC

-

16 A (MCB-B)

General data

Dimensions W/H/D

17.7 mm / 90 mm / 65.5 mm

17.7 mm / 90 mm / 65.5 mm

IEC connection data

Solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 80 °C

-40 °C ... 70 °C

Test standards

EN 61643-11 / IEC 61643-11

IEC 61643-11 / EN 61643-11

Ordering data

Ordering data

Description

 

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

MAINS-PLUGTRAB, 

consisting of a plug and base element

PT 2+1-S-48DC/FM

2817958

10

PLT-T3-IT-230-FM

2906450

1

Accessories

Accessories

Replacement plug

1L-N & N-PE

PT 2+1-S-48DC-ST

2839648

10

PLT-T3-IT-230-P

2906451

1

PLUGTRAB base element,

 for mounting on NS

 

35

PT-BE/FM

2839282

10

PT-BE/FM

2839282

10

72

PHOENIX CONTACT

– For 48 V DC or 230 V IT power supply 

equipment

– Pluggable
– Through wiring
– Optical status indicator via LED
– Tool-free connector replacement
– With floating remote indication contact
– Plugs can be checked with 

CHECKMASTER

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

H

W

D

H

W

D

Type 3 device protection
PLUGTRAB

Surge protection and interference suppression filters

Surge protection for the power supply

For 48 V DC power supplies

For 230 V AC power supplies,

3-conductor system, L1, L2, PE (IT systems)

phoenixcontact-protection-html.html
background image

PE

!

J

J

23

0

V

PE

!

23

0

 V

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Electrical data

IEC test classification

III / T3

III / T3

Nominal voltage U

N

230 V AC

230 V AC

Mode of protection

L-N / L-PE / N-PE

L-N / L-PE / N-PE

Maximum continuous operating voltage U

C

L-N / L-PE

275 V AC / 440 V AC

275 V AC / 440 V AC

Rated load current I

L

16 A (30 °C)

16 A (30 °C)

Nominal discharge current I

n

 (8/20) µs

3 kA

3 kA

Combined surge U

OC

6 kV

6 kV

Protection level U

p

L-N / L(N)-PE

 1.3 kV / 

 1.5 kV

 1.3 kV / 

 1.5 kV

Response time t

A

L-N / L(N)-PE

 25 ns / 

 100 ns

 25 ns / 

 100 ns

Backup fuse max. in acc. with IEC

16 A (MCB-B)

16 A (MCB-B)

General data

Dimensions W/H/D

22.5 mm / 43 mm / 27.4 mm

22.5 mm / 43 mm / 26.2 mm

IEC connection data

Solid/stranded/AWG

0.2...2.5

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 14

0.2...2.5

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 14

Temperature range

-30 °C ... 75 °C

-30 °C ... 75 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

BLOCKTRAB,

 for universal mounting

230 V AC

BT-1S-230AC/O

2800625

1

BT-1S-230AC/A

2803409

10

73

PHOENIX CONTACT

BT-1S-230AC/...

 serves as device 

protection in deep installation boxes (in acc. 
with DIN 49073), cable ducts, underfloor 
systems and terminal devices.
– With double spring-cage terminal blocks 

for tool-free conductor connection

– Side latches for easy fixing
– Optical/acoustic signaling of 

disconnection

Notes:

If only one value is specified under mode of protection in the 

technical data, this value is valid for all modes of protection 

specified.

Type 3 device protection
BLOCKTRAB

Surge protection and interference suppression filters

Surge protection for the power supply

For universal mounting, 

optical signaling

For universal mounting, 

acoustic signaling

phoenixcontact-protection-html.html
background image

N

PE

L

N

PE

L

3

/

5

2

2

/

4

1

Technical data

Technical data

Electrical data

Mains protection

Data protection

IEC test classification/EN type

III / T3

III / T3

C1

III / T3

C1

III / T3

C2

Nominal voltage U

N

230 V AC

230 V AC

Maximum continuous operating voltage U

C

L-N / L-PE

275 V AC / 360 V AC

275 V AC / 360 V AC

without reference direction

-

-

200 V DC

-

200 V DC

-

24 V DC

Combined surge U

OC

4 kV

4 kV

-

4 kV

-

4 kV

-

Nominal load current I

L

16 A (30 °C)

16 A (30 °C)

Rated current

-

-

150 mA (25 °C)

-

150 mA (25 °C)

-

1.5 A (25 °C)

Nominal discharge current I

n

 (8/20) µs

without reference direction

3 kA (> 5x)

3 kA (> 5x)

-

3 kA (> 5x)

-

3 kA (> 5x)

-

Core-Core / Core-Ground / Core-Shield

-

-

1 kA / 2.5 kA / -

-

1 kA / 2.5 kA / -

-

- / 2.5 kA / 2.5 kA

Protection level U

p

L-N / N-PE / L-PE

 1.2 kV / 

 1.5 kV / 

 1.5 kV

 1.2 kV / 

 1.5 kV / 

 1.5 kV

-

Core-Core / Core-Ground / Core-Shield

- / - / -

-

 460 V (C2 - 1 kA) / 

 900 V (C2 - 2 kA) / -

Response time t

A

L-N / L-PE

 25 ns / 

 100 ns

 25 ns / 

 100 ns

-

Core-Ground / Core-Shield / Shield-Ground

- / - / -

-

 25 ns / 

 100 ns / -

-

Cut-off frequency fg (3 dB)

In a 100 

 system

Core-Core

-

-

typ. 4 MHz

-

typ. 4 MHz

-

-

In a 75 

 

system

Core-Shield

-

-

-

-

-

-

typ.  2.5  GHz

General data

Dimensions W/H/D

56 mm / 76 mm / 78 mm

63 mm / 103 mm / 78 mm

63 mm / 103 mm / 78 mm

63 mm / 107 mm / 78 mm

Temperature range

-25 °C ... 75 °C

-25 °C ... 75 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11 / EN 61643-21 /

IEC 61643-11 / EN 61643-11 / EN 61643-21 /

IEC

Ordering data

Ordering data

Description

can be used in

the following:

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

MAINTRAB, 

attachment plug with signal lamp for plugging into a 

socket, for device protection

black

D, A, NL, E, S, FIN, TR

MNT-1 D

2882200

1

white

D, A, NL, E, S, FIN, TR

MNT-1 D/WH

2882213

1

black

D

MNT-TAE D

2882381

1

white

D

MNT-TAE D/WH

2882394

1

black

NL, E, I, S, FIN, TR

white

NL, E, I, S, FIN, TR

black

B, F, CZ, SVK, PL

MNT-NET B/F

2882226

1

black

CH

MNT-1 CH II

2882255

1

74

PHOENIX CONTACT

– Attachment plug in black or white
– For individual terminal devices
– With increased touch-proof protection
– Optical signaling of the surge voltage 

function via LED

– For protecting the power supply and 

signal lines

– Including required accessories
– Country-specific versions available

Type 3 device protection
MAINTRAB

Surge protection and interference suppression filters

Surge protection for the power supply

Attachment plug

For telecommunications systems 

with TAE connection

phoenixcontact-protection-html.html
background image

5

2

4

3

P

E

N

L

N

PE

L

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Mains protection

Data protection

Mains protection

Data protection

IEC test classification/EN type

III / T3

III / T3

C1

III / T3

C1

III / T3

C2

230 V AC

230 V AC

275 V AC / 360 V AC

275 V AC / 360 V AC

without reference direction

-

-

200 V DC

-

200 V DC

-

24 V DC

4 kV

4 kV

-

4 kV

-

4 kV

-

16 A (30 °C)

16 A (30 °C)

Rated current

-

-

150 mA (25 °C)

-

150 mA (25 °C)

-

1.5 A (25 °C)

without reference direction

3 kA (> 5x)

3 kA (> 5x)

-

3 kA (> 5x)

-

3 kA (> 5x)

-

Core-Core / Core-Ground / Core-Shield

-

-

1 kA / 2.5 kA / -

-

1 kA / 2.5 kA / -

-

- / 2.5 kA / 2.5 kA

 1.2 kV / 

 1.5 kV / 

 1.5 kV

-

 1.2 kV / 

 1.5 kV / 

 1.5 kV

-

-

 460 V (C2 - 1 kA) / 

 900 V (C2 - 2 kA) / -

-

-  /  -  / 

 700 V (C2 - 2 kA)

 25 ns / 

 100 ns

-

 25 ns / 

 100 ns

-

 100 ns / -

-

 25 ns / 

 100 ns / -

-

- / - / 

 100 ns

 system

Core-Core

-

-

typ. 4 MHz

-

typ. 4 MHz

-

-

 

system

Core-Shield

-

-

-

-

-

-

typ.  2.5  GHz

Dimensions W/H/D

56 mm / 76 mm / 78 mm

63 mm / 103 mm / 78 mm

63 mm / 103 mm / 78 mm

63 mm / 107 mm / 78 mm

-25 °C ... 75 °C

-25 °C ... 75 °C

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11 / EN 61643-21 /

IEC 61643-11 / EN 61643-11 / EN 61643-21 /

IEC 61643-11 / EN 61643-11 / EN 61643-21 /

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

MNT-TV-SAT D

2882284

1

MNT-TV-SAT D/WH

2882297

1

MNT-TELE E

2882417

1

MNT-TELE S/WH

2880901

1

MNT-TEL B/F

2882404

1

MNT-TV-SAT B/F

2882307

1

75

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for the power supply

For telecommunications systems 

with RJ12 connection

For network and TV antennas/cables and SAT 

systems, with F connector and IEC adapter

phoenixcontact-protection-html.html
background image

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Building set,

 consisting of:

1 x VAL-MS-T1/T2 (surge protective device),

1 x MNT-1D (device protection adapter),

1 x MNT-TV-SAT D (device and TV-SAT protective adapter),

1 x MNT-TAE D (device and TAE protective adapter),

2 x adapter F to TV (IEC) connector

1 x KBL TV-SAT/150, 1 x KBL TV/150,

1 x KBL TAE/150 (connecting cable)

GEB-SET-T1/T2 TAE/TV-SAT

2801022

1

76

PHOENIX CONTACT

– Surge protection set for powerful basic 

protection

– Coordinated protective devices
– VAL-MS-T1/T2 lightning current arrester 

for installation in the distribution

– Three device protection adapters (type 3) 

for protecting the power supply

– Two of these are equipped with additional 

signal line protection (TV/SAT or TAE)

– Cables and adapters are supplied as 

standard

Set solution for building installation

Surge protection and interference suppression filters

Surge protection for the power supply

Set solution with surge protection 

for TAE and TV-SAT

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Electrical data

Maximum continuous operating voltage U

C

500 V AC

-

Nominal current I

N

-

-

Impulse discharge curr. I

imp

 (10/350) 

μ

s

Peak value

100 kA

-

General data

Dimensions W/H/D

17.7 mm / 89.8 mm / 65.5 mm

Connection data solid/stranded/AWG

0.5...35

 

mm²

 

 

- mm²

 

/ 20 ... 2

2,5...95

 

mm²

 

 

- mm²

 

/ -

Temperature range

-40 °C ... 85 °C

-

Inflammability class in acc. with UL 94

V-0

-

Test standards

IEC

 

60947-7-1 / DIN EN 61643-11 / IEC 61643-1

-

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Feed-through terminal block

 with biconnect connecting terminal 

blocks as wiring aid for lightning current arrester and surge 

protective device applications.

DK-BIC-35

2749880

1

Equipotential bonding strip

PAS-1

2765615

1

H

W

D

Feed-through terminal block

– For wiring mixed combinations of 

lightning current arresters and surge 
protective devices

Equipotential bonding strip

– For main equipotential bonding according 

to DIN VDE 0100

– As well as for lightning protection 

equipotential bonding in acc. with 
DIN EN 62305

Feed-through terminal block and 
equipotential bonding strip

Surge protection and interference suppression filters

Surge protection for the power supply

Feed-through terminal block

Equipotential bonding strip

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Wiring bridge,

 for wiring applications with lightning current 

arresters and surge protective devices; these can be found on the 

website under the corresponding items

2-pos.

MPB 18/1- 2

2809209

10

3-pos.

MPB 18/1- 3

2809212

10

4-pos.

MPB 18/1- 4

2809225

10

5-pos.

MPB 18/1- 5

2817864

10

6-pos.

MPB 18/1- 6

2748564

10

8-pos.

MPB 18/1- 8

2748577

10

9-pos.

MPB 18/1- 9

2748580

10

12-pos.

MPB 18/1-12

2748593

10

57-pos.

MPB 18/1-57

2809238

1

Wiring bridge, 

35

 

mm²

6-pos.

MPB 18/1-6/35

2908705

10

8-pos.

MPB 18/1-8/35

2908704

10

Continuous roll,

 width: 20

 

mm

Color: white

EML (20XE)R

0803452

1

Color: yellow

EML (20XE)R YE

0803453

1

77

PHOENIX CONTACT

Marking material

– For clear and logical identification
– Can be marked with CMS computer 

marking system or by hand using B-STIFT

Wiring bridges

– 1-phase with various numbers of 

positions

Wiring bridges and marking materials

Wiring bridges

Marking label for the SEC product range

phoenixcontact-protection-html.html
background image

Ex: 

 

78

PHOENIX CONTACT

Isolating spark gap and accessories

– Isolating spark gap for indirect 

equipotential bonding

– Protection of insulating flanges in 

pipelines

– Can be used in Ex protection Zone 1
– Accessories for lightning current 

absorbing connection

Technical data

Electrical data

Lightning protection class

H

Lightning surge current I

imp 

(10/350) 

μ

s

100  kA

Nominal discharge  current I

n

 (8/20) µs

100 kA

Rated power-frequency withstand voltage U

wAC

 250 V AC

Rated DC withstand voltage U

wDC

 354 V DC

Rated impulse sparkover voltage U

r imp

 1.25 kV

General data

Dimensions: length/housing diameter

+2 mm / 45.50 mm

Temperature range

-20 °C ... 60 °C

Test standards

IEC 62561-3 / EN 62561-3

Approvals

EC-type examination certificate according to ATEX

DEKRA 14ATEX0050 X

ATEX

 II 2 G Ex d IIC T6 Gb

 II 2 D Ex tb IIIC T80 °C Db IP 66/67

IECEx

Ex d IIC T6 Gb

Ex tb IIIC T80 °C Db IP66/67

Ordering data

Description

Drill hole diameter

Type

Order No.

Pcs./Pkt.

Isolating spark gap for the hazardous area

FLT-ISG-100-EX

2905579

1

Fixing bracket

11 mm

14 mm

18 mm

22 mm

26 mm

30 mm

33 mm

36 mm

39 mm

42 mm

48 mm

56 mm

62 mm

Mounting rail

11 mm

14 mm

18 mm

22 mm

26 mm

30 mm

33 mm

36 mm

39 mm

42 mm

Connecting cable

, conductor cross section: 25

 

mm², conductor 

designation: H01

 

N2-D

Cable length: 100

 

mm

Cable length: 200

 

mm

Cable length: 300

 

mm

Surge protection and interference suppression filters

Surge protection for the power supply

Spark gap

Fixing bracket

Mounting rail

Connecting cable

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

79

PHOENIX CONTACT

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

FLT-ISG-BR-11

2905580

1

FLT-ISG-BR-14

2905581

1

FLT-ISG-BR-18

2905582

1

FLT-ISG-BR-22

2905583

1

FLT-ISG-BR-26

2905757

1

FLT-ISG-BR-30

2905758

1

FLT-ISG-BR-33

2905759

1

FLT-ISG-BR-36

2905760

1

FLT-ISG-BR-39

2905761

1

FLT-ISG-BR-42

2905762

1

FLT-ISG-BR-48

2905763

1

FLT-ISG-BR-56

2905764

1

FLT-ISG-BR-62

2905765

1

FLT-ISG-PL-11

2905584

1

FLT-ISG-PL-14

2905586

1

FLT-ISG-PL-18

2905587

1

FLT-ISG-PL-22

2905588

1

FLT-ISG-PL-26

2905745

1

FLT-ISG-PL-30

2905746

1

FLT-ISG-PL-33

2905747

1

FLT-ISG-PL-36

2905754

1

FLT-ISG-PL-39

2905755

1

FLT-ISG-PL-42

2905756

1

FLT-ISG-CA-100

2905589

1

FLT-ISG-CA-200

2905590

1

FLT-ISG-CA-300

2905591

1

Surge protection and interference suppression filters

Surge protection for the power supply

Spark gap

Fixing bracket

Mounting rail

Connecting cable

phoenixcontact-protection-html.html
background image

80

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

Surge protection in thin layers – 
TERMITRAB complete

Starting from an overall width of 3.5 mm, 

the TERMITRAB complete product range is 
a tailored product range for almost all 
applications in measurement and control 
technology. Depending on the type of signal 
to be protected, with 
TERMITRAB complete you will find an 
ideally suited circuit version in the portfolio.

Signaling and disconnection

The mechanical status indicator functions 

without additional auxiliary energy and 
displays the disconnection of a protective 
element in the event of an overload. This 
means you are constantly informed of the 
status and can replace the overloaded 
protective device.

Remote signaling

Thanks to the remote signaling modules 

that are available as an option, you can 
decide whether and when you require this 
feature. To monitor retrospectively, you can 
easily align remote signaling modules to 
protective devices that are already installed. 
If a protective element is disconnected in 
the event of an overload, the disconnect 
device closes the monitoring channel and 
group remote signaling is triggered. The 
overloaded device is detected on site by the 
status indicator – and that is purely 
mechanically, without auxiliary energy.

Universal use

The areas of application for 

TERMITRAB complete are so diverse that 
they can be used in any industry. Thanks to 
the narrow overall width, starting at 
3.5 mm, the product range is ideal for 
process technology, as very often a high 
packing density is required in the 
distribution cabinets. They protect up to 
572 signals on one meter, which means that 
your systems can be made smaller. The 
various approvals permit use in onshore and 
offshore systems, e.g., for petrochemicals 
or wind power. The tailored 
TERMITRAB complete portfolio offers you 
the widest range of features, and therefore 
an optimum product selection for your 
applications. This means you can reliably 
protect your signals against surge voltages – 
from the field to the controller.

Quick wiring

TERMITRAB complete is available with 

conventional screw connection and 
innovative Push-in connection technology. It 
guarantees quick and easy installation in the 
control cabinet. At the same time, the Push-
in connection technology enables 
mechanical wiring of the surge protective 
devices, within the scope of tomorrow's 
intelligent automation solutions.

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

81

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

The narrowest surge protection

Starting from an overall width of 3.5 mm, 

TERMITRAB complete is the world's first 
surge protection solution for measurement 
and control technology.

Innovative knife disconnection

The integrated knife disconnection 

enables the signal path to be broken up, e.g., 
to carry out isolation measurements. An 
open signal path is easy to detect from the 
projecting function screws. The screws are 
equipped with overwind protection.

Optional visual remote signaling

Up to 40 protective devices are visually 

monitored with the optional remote 
signaling modules. Add further protective 
devices easily to the monitoring system 
without additional wiring effort.

Plug in, remove, and test

For repeated tests, remove the 

connectors of multi-piece protective 
devices without impedance. The signals are 
not interrupted and the controllers do not 
immediately detect an impedance change in 
the measuring circuit. Testing and 
documentation takes place in the 
CHECKMASTER 2. If a replacement is 
required, the affected connector is simply 
replaced without accessing the installation.

Tailored portfolio

The portfolio ranges from single-stage, 

one-piece protective devices to multi-stage 
pluggable versions. A range of voltage and 
circuit versions that are optimized for 
different applications and various 
connection technologies complete the 
product range.

Versatile

Certain applications require special tests 

and approvals. TERMITRAB complete 
meets the requirements of Underwriters 
Laboratories (UL). Furthermore, versions 
with ATEX, IEC Ex, and GL approvals are 
available.

phoenixcontact-protection-html.html
background image

82

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

Intelligent and systematic surge 
protection – PLUGTRAB PT-IQ

The PLUGTRAB PT-IQ product range is 

the first to offer predictive function 
monitoring for surge protective devices in 
the context of measurement and control 
technology. Boasting a whole range of 
additional features, the new surge 
protection system is a real highlight from 
Phoenix Contact.

Always know what is happening – 
predictive monitoring

The individual components of the 

protective devices are permanently 
monitored. When the performance limit 
has been reached as a result of frequent 
surge voltages, this is indicated by the 
yellow status symbol. The arrester 
continues to function and your system is 
still protected. However, replacement of the 
protective plug is recommended. This 
ensures you are informed even earlier and 
can replace your surge protection before 
the protective plug is overloaded (red 
signal). Furthermore, if you use the remote 
signaling option, you can check how well 
your system is being protected – at any time 
and from any location.

Permanent and error-free installation

The PLUGTRAB PT-IQ minimizes the 

amount of wiring required. This is made 
possible by the DIN rail connector (TBUS), 
which is easily clipped onto the DIN rail. A 
controller handles the distribution of the 
power supply and implements remote 
signaling of all connected surge protective 
devices via the TBUS. All you have to do 
then is install the surge protective devices 
on the TBUS – and you're done! The plug 
and base element are coded to avoid 
installation errors during replacement.

Limitless extension

The controller monitors all arresters 

which are connected to the controller via 
the TBUS. You can bridge the TBUS across 
DIN rails to monitor even more protective 
devices. After 28 protective devices, an 
additional controller must be installed to 
supply voltage. Remote signaling can be 
performed from any controller in the 
system.

Other surge protective devices

PLUGTRAB PT are pluggable protective 

devices without remote signaling, also with 
circuit versions for intrinsically safe signal 
circuits.

The multi-level terminal blocks in the 

TERMITRAB or LINETRAB product ranges 
have an overall width of just 6.2 mm yet are 
able to offer protection for up to four signal 
wires.

As they are installed directly on 

measuring sensors, the SURGETRAB screw 
connection modules are able to provide 
reliable protection against transients even in 
Ex i and Ex d applications.

The products in the COMTRAB modular 

range have been designed specifically for use 
in marshalling distributors.

Your web code: 

#0144

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

83

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

Group message

– Green: protective device OK
– Yellow: performance limit reached, 

replacement recommended

– Red: protective device overloaded, 

replace

Multi-stage remote signaling

Connect the remote signaling to the 

controller that acts as a supply and remote 
module (one-off connection operation). 
The status is output according to the 
priority as red, yellow or green. This 
ensures you always know what is happening 
and can always keep an eye on your system's 
protection.

TBUS DIN rail connector

The DIN rail connector (TBUS) supplies 

voltage to the protection modules and 
forwards the status of each individual 
arrester to the controller. You benefit from 
the reduced wiring costs and can implement 
surge protection quickly without errors.

For Ex Zone 2

With the PLUGTRAB PT-IQ Ex 

protective devices, it is possible for the first 
time to install protective devices with multi-
stage monitoring and remote signaling 
directly in Ex Zone 2. The intrinsically safe 
protective circuits can be led up to 
Ex Zone 0.

Special systems

Implement protection in the field directly 

at the measuring sensor with SURGETRAB 
screw connection modules.

phoenixcontact-protection-html.html
background image

ϑ

U

Application

Ins

tal

la

ti

on 

pr

oper

ti

es

Current loops 

0(4) mA ... 20 mA

1

)

6.2

D1/C2/C1

1

)

17.5

D1/C2/C1

Current loops 

0(4) mA ... 20 mA

with power supply cable

1

)

6.2

D1/C2/C1

1

)

17.5

D1/C2/C1

Analog signal 

0 V ... 10 V

1

)

6.2

D1/C2/C1

1

)

17.5

D1/C2/C1

Resistance-dependent measurement 

e.g., with Pt 100

1

)

6.2

D1/C2/C1

Digital input/

digital output

Common reference conductor:

isolated from ground

1

)

6.2

D1/C2/C1

1

)

17.5

D1/C2/C1

Common reference conductor:

directly grounded

1

)

6.2

D1/C2/C1

1

)

17.5

D1/C2/C1

Digital output

> 600 mA

Common reference conductor:

isolated from ground

1

)

6.2

D1/C2/C1

1

)

17.5

D1/C2/C1

Common reference conductor:

directly grounded

1

)

17.5

D1/C2/C1

Selection guide

Explanation of the IEC categories

LPZ 
zone

Test category 
for SPD 
corresponds 
to
IEC 61643-21

Test class for 
SPD 
corresponds 
to
IEC 61643-11

0/1

D1

I

1/2

C2

II

2/3

C1

III

Note

Products bearing this stamp 

(plug elements) can be tested 
with the CHECKMASTER.

Data for fault analysis 

according to IEC 61508 is 
available on the Internet.

DIN rail mounting

Push-in connection

Screw connection

Cables

1

)

Also available with screw connection 

technology

84

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Ov

erall

 

wi

dth 

in

 mm

IEC 

ca

te

g

o

r

y

Sta

tu

di

spl

a

y

Pl

u

ggab

le

Kni

fe di

s-

c

o

nne

c

ti

o

n

IQ fu

nc

ti

o

n

 

mo

nit

o

r

in

g

Pr

o

te

c

te

d

 

wi

res

Surge protective device 
(SPD)

Order No.

Page

3.5

D1/C2/C1

2

TTC-3-1X2-24DC-PT

2907325

 95

)

6.2

D1/C2/C1

2

TTC-6P-1X2-M-24DC-PT-I

2906750

 92

)

17.5

D1/C2/C1

3

PT-IQ-1X2-24DC-PT

2801255

 96

> 17.5

D1/C2/C1

2

S-PT-1X2-24DC

2880668

 101

6.2

D1/C2/C1

2

TTC-6P-1X2-M-EX-24DC-UT-I

2906824

 128

17.5

D1/C2/C1

4

PT-IQ-2X2-EX-24DC-UT

2801513

 129

> 17.5

D1/C2/C1

2

S-PT-EX(I)-24DC

2880671

 130

3.5

D1/C2/C1

3

TTC-3-2X1-24DC-PT

2907326

 109

)

6.2

D1/C2/C1

3

TTC-6P-2X1-M-24DC-PT-I

2906753

 104

)

17.5

D1/C2/C1

3

PT-IQ-2X1-24DC-PT

2801247

 110

> 17.5

D1/C2/C1

4

S-PT-4-EX-24DC

2800036

 118

6.2

D1/C2/C1

3

TTC-6P-2X1-M-EX-24DC-UT-I

2906825

 133

> 17.5

D1/C2/C1

4

S-PT-4-EX-24DC

2800036

 118

3.5

D1/C2/C1

2

TTC-3-1X2-24DC-PT

2907325

 95

)

6.2

D1/C2/C1

2

TTC-6P-1X2-12DC-PT-I 

2908193

 

92

)

17.5

D1/C2/C1

2

PT-IQ-1X2-12DC-PT

2801253

 96

> 17.5

D1/C2/C1

2

S-PT-1X2-24DC

2880668

 101

)

6.2

D1/C2/C1

2

TTC-6P-2-HC-M-24DC-PT-I

2906755

 106

> 17.5

D1/C2/C1

2

S-PT-EX-24DC

2800034

 130

)

6.2

D1/C2/C1

3

TTC-6P-2X1-F-M-24DC-PT-I

2906794

 105

)

17.5

D1/C2/C1

5

PT-IQ-4X1+F-24DC-PT

2801272

 111

> 17.5

D1/C2/C1

5

S-PT-4-EX-24DC

2800036

 118

3.5

D1/C2/C1

3

TTC-3-2X1-24DC-PT

2907326

 109

)

6.2

D1/C2/C1

3

TTC-6P-2X1-M-24DC-PT-I

2906753

 104

)

17.5

D1/C2/C1

5

PT-IQ-4X1-24DC-PT

2801271

 111

> 17.5

D1/C2/C1

5

S-PT-4-EX-24DC

2800036

 118

)

6.2

D1/C2/C1

3

TTC-6P-2-HC-M-24DC-PT-I

2906755

 106

)

17.5

D1/C2/C1

5

PT-IQ-4X1+F-24DC-PT

2801272

 111

> 17.5

D1/C2/C1

2

S-PT-EX-24DC

2800034

 130

)

17.5

D1/C2/C1

5

PT-IQ-4X1-24DC-PT

2801271

 111

85

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

phoenixcontact-protection-html.html
background image

4...

2

0 mA

4

5

6

1

2

3

P

LC

4...

2

0 mA

4

5

6

1

2

3

4...

2

0 mA

+

˜

˜

4...

2

0 mA

4

5

6

1

2

3

P

LC

4...

2

0 mA

P

LC

4...

2

0 mA

+

2

4 V

0 V G

N

D

1

2

3

4

5

6

4

5

6

1

2

3

Protection of a 0(4) ... 20 mA current loop

Suitable products

TTC-6P-1X2-M-24DC-PT-I

Suitable products

TTC-6P-1X2-M-24DC-PT-I

2906750

2906750

Page 92

Page 92

Protection of a 0(4) ... 20 mA current loop, intrinsically safe circuits

Suitable products

S-PT-EX-24DC

Suitable products

TTC-6P-1x2-M-EX-24DC-UT-I

2800034

2906824

Page 130

Page 128

Protection of a 0(4) ... 20 mA current loop and additional power supply

Suitable products

TTC-6P-2X1-F-M-24DC-PT-I

Suitable products

TTC-6P-2X1-F-M-24DC-PT-I

2906794

2906794

Page 105

Page 105

86

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

phoenixcontact-protection-html.html
background image

7

11

9

3

8

1

2

10

4

7

11

9

3

8

1

2

10

4

4...

2

0 mA

P

LC

4...

2

0 mA

7

11

9

3

8

1

2

10

4

P

LC

4...

2

0 mA

4...

2

0 mA

7

11

9

3

8

1

2

10

4

7

11

9

3

8

1

2

10

4

4...

2

0 mA

P

LC

0 V G

N

D

+

2

4 V

4...

2

0 mA

For further information and full technical data, visit phoenixcontact.net/products

Protection of a 0(4) ... 20 mA current loop

Suitable products

PT-IQ-1X2-24DC-PT

Suitable products

PT-IQ-1X2-24DC-PT

2801255

2801255

Page 96

Page 96

Protection of a 0(4) ... 20 mA current loop, intrinsically safe circuits

Suitable products

S-PT-EX(I)-24DC

Suitable products

PT-IQ-1X2-EX-24DC-UT

2880671

2801512

Page 130

Page 129

Protection of a 0(4) ... 20 mA current loop and additional power supply

Suitable products

PT-IQ-2X1+F-24DC-PT

Suitable products

PT-IQ-2X1-24DC-PT

2801248

2801247

Page 111

Page 110

87

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

phoenixcontact-protection-html.html
background image

L+

0 V G

N

D

P

LC

4

5

6

1

2

3

4

5

6

1

2

3

U

L+

0 V G

N

D

P

LC

4

5

6

1

2

3

4

5

6

1

2

3

U

Protection of a digital I/O (24 V), reference conductor not grounded

Suitable products

TTC-6P-2X1-F-M-24DC-PT-I

2906794

Page 105

Protection of a digital I/O (24 V), reference conductor not grounded

Suitable products

TTC-6P-2X1-M-24DC-I

2906753

Page 104

88

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

phoenixcontact-protection-html.html
background image

1

5

7

11

9

3

2

6

8

1

2

10

4

P

LC

L+

0 V G

N

D

U

1

5

7

11

9

3

2

6

8

1

2

10

4

P

LC

L+

0 V G

N

D

U

For further information and full technical data, visit phoenixcontact.net/products

Protection of a digital I/O (24 V), reference conductor not grounded

Suitable products

PT-IQ-4X1+F-24DC-PT

2801272

Page 111

Protection of a digital I/O (24 V), reference conductor not grounded

Suitable products

PT-IQ-4X1-24DC-PT

2801271

Page 111

89

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

phoenixcontact-protection-html.html
background image

+

˜

˜

4

5

6

1

2

3

P

LC

U

U

ϑ

P

LC

I

1

5

7

11

9

3

2

6

8

1

2

10

4

U
U

I

Protection of a two-wire temperature measurement

Suitable products

S-PT-EX-24DC

Suitable products

TTC-6P-2-HC-M-24DC-PT-I

2800034

2906755

Page 130

Page 106

Protection of a four-wire temperature measurement

Suitable products

PT-IQ-4X1+F-12DC-PT

2801272

Page 111

90

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

phoenixcontact-protection-html.html
background image

+

˜

˜

4

5

6

1

2

3

L+

L-

P

LC

For further information and full technical data, visit phoenixcontact.net/products

Protection of a digital output (actuator)

Suitable products

S-PT-EX-24DC

Suitable products

TTC-6P-2-HC-M-24DC-PT-I

2800034

2906755

Page 130

Page 106

91

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

4

5

6

1

2

3

unprotected

protected

Technical data

Technical data

Electrical data

... 12DC

... 24DC

... 48DC

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

15 V DC

30 V DC

55.2 V DC

30 V DC

Rated current

600 mA (40°C)

600 mA (40°C)

160 mA (75°C)

600 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

0.5 kA

0.5 kA

0.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

5 kA / 5 kA

5 kA / 5 kA

5 kA / 5 kA

5 kA / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

10 kA

10 kA

10 kA

Protection level U

p

Core-Core

 25 V (C3 - 

25 A)

 50 V (C3 - 

25 A)

 85 V (C3 - 

25 A)

 50 V (C3 - 

25 A)

Core-Ground

 700 V (C3 - 

25 A)

 700 V (C3 - 

25 A)

 700 V (C3 - 

25 A)

 700 V (C3 - 

25 A)

Cut-off frequency fg (3 dB)

Symmetrical in the 150 

 system

typ. 420 kHz

typ. 940 kHz

typ. 1.8 MHz

typ. 940 kHz

Resistance per path

1.65 

1.65 

1.65 

1.65 

General data

Dimensions W/H/D

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TERMITRAB complete, 

with screw connection technology

12 V DC

TTC-6P-1X2-12DC-UT-I

2908192

1

24 V DC

TTC-6P-1X2-24DC-UT-I

2906809

1

TTC-6P-1X2-M-24DC-UT-I

2906738

1

48 V DC

TTC-6P-1X2-48DC-UT-I

2908194

1

TERMITRAB complete,

 with Push-in connection technology

12 V DC

TTC-6P-1X2-12DC-PT-I

2908193

1

24 V DC

TTC-6P-1X2-24DC-PT-I

2906815

1

TTC-6P-1X2-M-24DC-PT-I

2906750

1

48 V DC

TTC-6P-1X2-48DC-PT-I

2908195

1

Accessories

Accessories

Remote signaling set

Screw connection technology

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-UT

2907810

1

Push-in connection technology

TTC-6-FMRS-PT

2907811

1

TTC-6-FMRS-PT

2907811

1

92

PHOENIX CONTACT

– Pluggable surge protection
– Overall width of just 6.2 mm
– With Push-in or screw connection 

technology

– Impedance-neutral insertion and removal
– Coded connector versions
– With knife disconnection as an option
– Integrated mechanical status indicator
– Optional remote signaling module 

monitors up to 40 items, without 
additional wiring

– Plugs can be tested with 

CHECKMASTER 2

Current loops and analog signals
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

Double wire (loop), floating, 3/6 connection 

grounded directly, e.g.,

 

for 4

 

...

 

20

 

mA current 

loop

Double wire (loop), floating, 3/6 connection 

grounded directly, with knife disconnection, 

e.g.,

 

for 4

 

...

 

20

 

mA current loop

new

new

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

4

5

6

1

2

3

unprotected

protected

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

... 12DC

... 48DC

... 24DC

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

15 V DC

55.2 V DC

30 V DC

600 mA (40°C)

160 mA (75°C)

600 mA (40°C)

0.5 kA

0.5 kA

0.5 kA

5 kA / 5 kA

5 kA / 5 kA

5 kA / 5 kA

10 kA

10 kA

10 kA

 25 V (C3 - 

25 A)

 85 V (C3 - 

25 A)

 50 V (C3 - 

25 A)

 1.3 kV (C3 - 

25 A)

 1.3 kV (C3 - 

25 A)

 1.3 kV (C3 - 

25 A)

typ. 420 kHz

typ. 1.8 MHz

typ. 940 kHz

1.65 

1.65 

1.65 

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-40 °C ... 85 °C

-40 °C ... 85 °C

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TTC-6P-1X2-F-12DC-UT-I

2908196

1

TTC-6P-1X2-F-M-24DC-UT-I

2906781

1

TTC-6P-1X2-F-48DC-UT-I

2908199

1

TTC-6P-1X2-F-12DC-PT-I

2908198

1

TTC-6P-1X2-F-M-24DC-PT-I

2906790

1

TTC-6P-1X2-F-48DC-PT-I

2908200

1

Accessories

Accessories

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-PT

2907811

1

TTC-6-FMRS-PT

2907811

1

93

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

Double wire (loop), floating, 3/6 connection 

grounded via gas-filled surge arrester, 

e.g.,

 

for 4

 

... 

 

20

 

mA current loop

Double wire (loop), floating, 3/6 connection 

grounded via gas-filled surge arrester, with knife 

disconnection, e.g.,

 

for 4

 

... 

 

20m

 

A current loop

new

new

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

4

5

6

1

2

3

unprotected

protected

Technical data

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

30 V DC

30 V DC

Rated current

600 mA (40°C)

600 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

0.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

5 kA / 5 kA

5 kA / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

10 kA

Protection level U

p

Core-Core

 50 V (C3 - 25 A)

 50 V (C3 - 25 A)

Core-Ground

 700 V (C3 - 25 A)

 1.3 kV (C3 - 25 A)

Cut-off frequency fg (3 dB)

Symmetrical in the 150 

 system

typ. 940 kHz

typ. 940 kHz

Resistance per path

1.65 

1.65 

General data

Dimensions W/H/D

6.2 mm

 

/

 

105.8 mm

 

/

 

69.5 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

83.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TERMITRAB complete, 

with screw connection technology

Without status indicator

24 V DC

TTC-6-1X2-24DC-UT

2906798

1

With status indicator

24 V DC

TTC-6-1X2-M-24DC-UT-I

2906713

1

TTC-6-1X2-F-M-24DC-UT-I

2906764

1

TERMITRAB complete,

 with Push-in connection technology

Without status indicator

24 V DC

TTC-6-1X2-24DC-PT

2906804

1

With status indicator

24 V DC

TTC-6-1X2-M-24DC-PT-I

2906726

1

TTC-6-1X2-F-M-24DC-PT-I

2906772

1

Accessories

Accessories

Remote signaling set

Screw connection technology

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-UT

2907810

1

Push-in connection technology

TTC-6-FMRS-PT

2907811

1

TTC-6-FMRS-PT

2907811

1

94

PHOENIX CONTACT

– Overall width of just 6.2 mm
– With Push-in or screw connection 

technology

– With integrated mechanical status 

indicator and knife disconnection as an 
option

– Optional remote signaling module 

monitors up to 40 items, without 
additional wiring

H

W

D

new

H

W

D

new

Current loops and analog signals
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

Double wire (loop), floating, 3/6 connection 

grounded directly, e.g.,

 

for 4

 

...

 

20

 

mA current 

loop

Double wire (loop), floating, 3/6 connection 

grounded via gas-filled surge arrester, with knife 

disconnection, e.g.,

 

for 4

 

... 

 

20 m

 

A current loop

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

30 V DC

Rated current

250 mA (70°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

5 kA / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

Protection level U

p

Core-Core

 45 V (C3 - 30 A)

Core-Ground

 1000 V (C3 - 100 A)

Cut-off frequency fg (3 dB)

Symmetrical in the 150 

 system

typ. 2.4 MHz

Resistance per path

2.2 

General data

Dimensions W/H/D

3.5 mm

 

/

 

106 mm

 

/

 

69.5 mm

Connection data solid/stranded/AWG

0.2...1.5

 

mm²

 

/ 0.2...1.5

 

mm²

 

/ 24 ... 16

Temperature range

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

TERMITRAB complete,

 with Push-in connection technology

24 V DC

TTC-3-1X2-24DC-PT

2907325

1

Accessories

End cover

TTC-3-LCP

2908843

1

95

PHOENIX CONTACT

– Overall width of just 3.5 mm
– With Push-in connection technology

H

W

D

new

Current loops and analog signals
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

Double wire (loop), floating, 

e.g., for 4 ... 20

 

mA current loops  

phoenixcontact-protection-html.html
background image

5

1

3

6

2

4

12

1

0

8

FM

FM

DC

 +

DC

Powe

r

S

P

D

DC

 +

DC

DC

FM

7

11

9

3

8

12

1

0

4

protected

unprotected

 

 

 

Technical data

Technical data

Electrical data

... 5DC

... 12DC

... 24DC

... 48DC

IEC test classification/EN type

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

Maximum continuous operating voltage U

C

-

6  V  DC

 

/

4 V AC

15 V DC

 

/

10 V AC

30 V DC

 

/

21 V AC

53 V DC

 

/

37 V AC

Rated current

-

1000 mA 

(40°C)

1000 mA 

(40°C)

1000 mA 

(40°C)

300 mA

1000 mA 

Pulse discharge current I

imp

 (10/350) µs

-

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

- / -

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 

Total discharge current I

total 

(8/20)

 

µs

-

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

Protection level U

p

Core-Core

-

 25 V (C3 - 

25 A)

 35 V (C3 - 

25 A)

 55 V (C3 - 

25 A)

 90 V (C3 - 

25 A)

Core-Ground

-

 700 V (C3 - 

25 A)

 700 V (C3 - 

25 A)

 700 V (C3 - 

25 A)

 700 V (C3 - 

25 A)

Resistance per path

-

1.2 

1.2 

1.2 

1.2 

General data

PT-IQ...UT dimensions W/H/D

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

17.7 mm

PT-IQ...PT dimensions W/H/D

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

17.7 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

Temperature range

-40 °C ... 70 °C

-40 °C ... 70 °C

Test standards

EN 61000-6-2 / EN 61000-6-3 / EN 60950-1 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-3 /

IEC 61643-21 / EN 61643-21 /

EN 60079-0 / EN 60079-11 / EN 60079-15

EN 61000-6-2

Remote indication contact

2x N/C contacts

Via TBUS

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 14

-

 

mm²

 

/ -

 

mm²

 

/ -

Max. operating voltage

30 V AC (50/60 Hz, non-Ex) / 50 V DC (non-Ex)

-

Max. operating current

1 A (up to 50°C, non-Ex)

-

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PLUGTRAB, 

supply and remote signaling module

Screw connection technology

PT-IQ-PTB-UT

2800768

1

Push-in connection technology

PT-IQ-PTB-PT

2801296

1

PLUGTRAB,

 with screw connection technology

5 V DC

PT-IQ-1X2-5DC-UT

2800791

1

12 V DC

PT-IQ-1X2-12DC-UT

2800793

1

24 V DC

PT-IQ-1X2-24DC-UT

2800976

1

48 V DC

PT-IQ-1X2-48DC-UT

2800978

1

PLUGTRAB,

 with Push-in connection technology

5 V DC

PT-IQ-1X2-5DC-PT

2801251

1

12 V DC

PT-IQ-1X2-12DC-PT

2801253

1

24 V DC

PT-IQ-1X2-24DC-PT

2801255

1

48 V DC

PT-IQ-1X2-48DC-PT

2801257

1

96

PHOENIX CONTACT

– Multi-stage status monitoring
– Group message via supply and remote 

signaling module

– Multi-stage, floating remote signaling
– System supplied via DIN rail bus
– Up to 28 protection modules per supply 

module

– Maximum ease of maintenance thanks to 

the two-piece design

– Plugs  are  coded
– Impedance-neutral disconnection of plug 

for maintenance purposes

– PT-IQ... base element with Push-in or 

screw connection technology

– Base element remains an integral part of 

the installation

– Corresponding replacement plugs can be 

found on our website

Current loops and analog signals
PLUGTRAB PT-IQ

Surge protection and interference suppression filters

Surge protection for MCR technology

Supply and remote signaling module

Double wire (loop), floating, 

connection 9/10 grounded directly, 

e.g., for 4 ... 20

 

mA current loop  

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

7

11

9

3

8

12

1

0

4

protected

unprotected

1

5

3

9

7

11

2

6

4

1

0

8

12

protected

unprotected

1

5

3

9

7

11

2

6

4

1

0

8

12

protected

unprotected

For further information and full technical data, visit phoenixcontact.net/products

 

 

Technical data

Technical data

Technical data

... 5DC

... 12DC

... 24DC

... 48DC

... 5DC

... 12DC

... 24DC

... 48DC

... 5DC

... 12DC

... 24DC

... 48DC

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

6 V DC

 

/

4 V AC

15 V DC

 

/

10 V AC

30 V DC

 

/

21 V AC

53 V DC

 

/

37 V AC

6 V DC

 

/

4 V AC

15 V DC

 

/

10 V AC

30 V DC

 

/

21 V AC

53 V DC

 

/

37 V AC

6 V DC

 

/

4 V AC

15 V DC

 

/

10 V AC

30 V DC

 

/

21 V AC

53 V DC

 

/

37 V AC

300 mA

1000 mA 

(40°C)

1000 mA 

(40°C)

1000 mA 

(40°C)

300 mA

700 mA (50 °C)

700 mA (50 °C)

700 mA (50 °C)

300 mA

700 mA (50 °C)

700 mA (50 °C)

700 mA (50 °C)

300 mA

 (10/350) µs

-

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

Core-Core / Core-Ground

- / -

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

µs

-

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

 25 V (C3 - 

25 A)

 35 V (C3 - 

25 A)

 55 V (C3 - 

25 A)

 90 V (C3 - 

25 A)

 25 V (C3 - 

25 A)

 35 V (C3 - 

25 A)

 55 V (C3 - 

25 A)

 90 V (C3 - 

25 A)

 25 V (C3 - 

25 A)

 35 V (C3 - 

25 A)

 55 V (C3 - 

25 A)

 90 V (C3 - 

25 A)

 1000 V (C3 - 

25 A)

 1000 V (C3 - 

25 A)

 1000 V (C3 - 

25 A)

 1000 V (C3 - 

25 A)

 700 V (C3 - 

25 A)

 700 V (C3 - 

25 A)

 700 V (C3 - 

25 A)

 700 V (C3 - 

25 A)

 1000 V (C3 - 

25 A)

 1000 V (C3 - 

25 A)

 1000 V (C3 - 

25 A)

 1000 V (C3 - 

25 A)

1.2 

1.2 

1.2 

1.2 

1.2 

1.2 

1.2 

1.2 

1.2 

1.2 

1.2 

1.2 

77.5 mm

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

77.5 mm

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-40 °C ... 70 °C

-40 °C ... 70 °C

-40 °C ... 70 °C

Test standards

EN 61000-6-2 / EN 61000-6-3 / EN 60950-1 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-3 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-3 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-3 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

EN 61000-6-2

EN 61000-6-2

EN 61000-6-3

Via TBUS

Via TBUS

Via TBUS

-

 

mm²

 

/ -

 

mm²

 

/ -

-

 

mm²

 

/ -

 

mm²

 

/ -

-

 

mm²

 

/ -

 

mm²

 

/ -

-

-

-

-

-

-

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PT-IQ-1X2+F-5DC-UT

2800792

1

PT-IQ-2X2-5DC-UT

2800807

1

PT-IQ-2X2+F-5DC-UT

2800809

1

PT-IQ-1X2+F-12DC-UT

2800975

1

PT-IQ-2X2-12DC-UT

2800984

1

PT-IQ-2X2+F-12DC-UT

2800985

1

PT-IQ-1X2+F-24DC-UT

2800977

1

PT-IQ-2X2-24DC-UT

2800980

1

PT-IQ-2X2+F-24DC-UT

2800981

1

PT-IQ-1X2+F-48DC-UT

2800979

1

PT-IQ-2X2-48DC-UT

2800986

1

PT-IQ-2X2+F-48DC-UT

2800987

1

PT-IQ-1X2+F-5DC-PT

2801252

1

PT-IQ-2X2-5DC-PT

2801259

1

PT-IQ-2X2+F-5DC-PT

2801260

1

PT-IQ-1X2+F-12DC-PT

2801254

1

PT-IQ-2X2-12DC-PT

2801261

1

PT-IQ-2X2+F-12DC-PT

2801262

1

PT-IQ-1X2+F-24DC-PT

2801256

1

PT-IQ-2X2-24DC-PT

2801263

1

PT-IQ-2X2+F-24DC-PT

2801264

1

PT-IQ-1X2+F-48DC-PT

2801258

1

PT-IQ-2X2-48DC-PT

2801265

1

PT-IQ-2X2+F-48DC-PT

2801266

1

97

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

H

W

D

Double wire (loop), floating, 

connection 9/10 grounded via gas-filled surge 

arrester, e.g., for 4 ... 20 mA current loop  

2 double wires (loops), floating, 

connection 9/10 grounded directly, 

e.g., for 4 ... 20

 

mA current loop

2 double wires (loops), floating, connection 

9/10 grounded via gas-filled surge arrester, 

e.g., for 4 ... 20

 

mA current loop

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

*

IN

OU

T

1

0

9

4

3

8

7

12

11

*

IN

OU

T

1

0

9

4

3

8

7

12

11

 

Ex: 

 

 

Ex: 

 

Technical data

Technical data

Electrical data

... 5DC

... 12DC

... 24DC

... 48DC

... 12AC

... 24AC

IEC test classification/EN type

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / 

Maximum continuous operating voltage U

C

6 V DC  / 

4 V AC

13 V DC / 

9 V AC

28 V DC / 

20 V AC

53 V DC /

37 V AC

18 V DC  / 

13 V AC

40 V DC / 

28 V AC

Rated current

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45

Pulse discharge current I

imp

 (10/350) µs

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

-

2.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

-

20 kA

Max. discharge current I

max.

 (8/20) µs

10 kA

10 kA

10 kA

20 kA (in total)

10 kA

10 kA

10 kA

10 kA

20 kA (in total)

20 kA (in total)

2 kA

20 kA (in total)

Protection level U

p

Core-Core

 40 V

 50 V

 50 V (C3 - 

25 A)

 80 V (C1 - 

1 kV/500 A)

 55 V

 80 V

-

-

Core-Ground

 450 V

 450 V

 450 V (C1 - 

1 kV/500 A)

 550 V (C2 - 

2

 

kV / 1

 

kA with 

PT 1X2-BE)

 450 V

 450 V

-

-

Output voltage limitation at 1 kV/µs

Core-Core

 10 V

 18 V

 40 V

 70 V

 25 V

 55 V

Core-Ground

 450 V

 450 V

 450 V

 450 V (with 

PT 1X2-BE)

 450 V

 450 V

Cut-off frequency fg (3 dB)

Symmetrical in the 50 

 system

typ. 1 MHz

typ. 3 MHz

typ. 4.5 MHz

typ. 10 MHz

typ. 4 MHz

typ. 8 MHz

typ. 1 MHz

typ. 3 MHz

typ. 4.5 MHz

typ. 8 MHz

-

typ. 8 MHz

Resistance per path

2.2 

2.2 

2.2 

2.2 

2.2 

2.2 

General data

Dimensions W/H/D

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

IEC 61643-21

IEC 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PLUGTRAB plug,

 with protective circuit for plugging into the PT 

base element

5 V DC

PT 1X2- 5DC-ST

2856016

10

12 V DC

PT 1X2-12DC-ST

2856029

10

24 V DC

PT 1X2-24DC-ST

2856032

10

48 V DC

PT 1X2-48DC-ST

2803658

10

12 V AC

PT 1X2-12AC-ST

2856045

10

24 V AC

PT 1X2-24AC-ST

2856058

10

PLUGTRAB base element,

 for mounting on NS

 

35

Bridge between 3/4 (

) and 9/10

PT 1X2-BE

2856113

10

PT 1X2-BE

2856113

10

Gas-filled surge arrester between 3/4 (

) and 9/10

PT 1X2+F-BE

2856126

10

PT 1X2+F-BE

2856126

10

98

PHOENIX CONTACT

– Consistently pluggable signal circuit 

protection

– Maximum ease of maintenance thanks to 

the two-piece design

– Base element remains an integral part of 

the installation

– Impedance-neutral disconnection of plug 

for test and maintenance purposes

– Plugs can be checked with 

CHECKMASTER

* Note:

Various grounding options for the base 
elements:

PT .x.-BE

 connections 9/10 (GND) 

directly connected to the mounting foot.

PT .x.+F-BE

 connections 9/10 (GND) 

connected to the mounting foot via a gas-
filled surge arrester.

Current loops and analog signals
PLUGTRAB PT

Surge protection and interference suppression filters

Surge protection for MCR technology

Double wire (loop), floating, 

e.g., for 4 ... 20

 

mA current loops  

Double wire (loop), floating, 

e.g., for 4 ... 20

 

mA current loops  

phoenixcontact-protection-html.html
background image

*

IN

OU

T

4

3

1

0

9

2

1

12

11

6

5

8

7

*

IN

OU

T

4

3

1

0

9

2

1

12

11

6

5

8

7

IN

OU

T

12(+)

11(+)

7

(-)

8

(-)

5

6

1

2

3

4

For further information and full technical data, visit phoenixcontact.net/products

 

Ex: 

 

 

 

Ex: 

 

Technical data

Technical data

Technical data

... 5DC

... 12DC

... 24DC

... 24AC

Mains protection

Data protection

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

III / T3

C1 / C2 / C3 / D1

6 V DC

 

/

4 V AC

13 V DC

 

/

9 V AC

28 V DC

 

/

20 V AC

40 V DC / 

28 V AC

44 V DC  / 

34 V AC

40 V DC  / 

28 V AC

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

6 A (30 °C)

450 mA (45°C)

 (10/350) µs

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

-

2.5 kA

Core-Core / Core-Ground

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

700 A

10 kA / 10 kA

µs

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

-

20 kA

 (8/20) µs

10 kA

10 kA

10 kA

20 kA (in total)

10 kA

10 kA

10 kA

10 kA

20 kA (in total)

20 kA (in total)

2 kA

20 kA (in total)

 80 V

-

-

 50 V (C3 - 25 A)

 80 V (C2 - 10 kV / 5 kA)

 0.18 kV

 80 V (C2 - 10 kV / 5 kA)

 450 V

-

-

 450 V (C1 - 1

 

kV / 

500

 

A with PT 2X2-BE)

 450 V (C2 - 10

 

kV / 5

 

kA with PT 2X2-BE)

 0.55 kV

 450 V (C2 - 10 kV / 5 kA)

 10 V

 18 V

 40 V

 55 V

-

 55 V

 450 V

 450 V

 450 V (with PT 2X2-BE)

 450 V (with PT 2X2-BE)

-

 25 V

 system

typ. 1 MHz

typ. 3 MHz

typ. 4.5 MHz

typ. 10 MHz

typ. 4 MHz

typ. 8 MHz

typ. 1 MHz

typ. 3 MHz

typ. 4.5 MHz

typ. 8 MHz

-

typ. 8 MHz

2.2 

2.2 

2.2 

2.2 

-

2.2 

65.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-40 °C ... 85 °C

-40 °C ... 85 °C

-40 °C ... 85 °C

IEC 61643-21

IEC 61643-21 / EN 61643-21

IEC 61643-11 / EN 61643-11 / EN 61643-21

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PT 2X2- 5DC-ST

2838241

10

PT 2X2-12DC-ST

2838254

10

PT 2X2-24DC-ST

2838228

10

PT 2X2-24AC-ST

2838283

10

PT PE/S+1X2-24-ST

2819008

10

PT 2X2-BE

2839208

10

PT 2X2-BE

2839208

10

PT 2X2+F-BE

2839224

10

PT 2X2+F-BE

2839224

10

PT PE/S+1X2-BE

2856265

10

99

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

H

W

D

2 double wires (loops), floating, 

e.g., for 4 ... 20

 

mA current loops  

2 double wires (loops), floating, 

e.g., for 4 ... 20

 

mA current loops  

Combination of double wire protection 

(floating) and single-phase power supply

phoenixcontact-protection-html.html
background image

IN

OU

T

7

5

3

1

8

6

4

2

IN

OU

T

7

5

3

1

8

6

4

2

 

 

Ex: 

 

 

 

 

Ex: 

 

 

Technical data

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

36 V DC / 25 V AC

36 V DC / 25 V AC

Rated current

350 mA (40°C)

350 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

500 A

500 A

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

5 kA / 5 kA

5 kA / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

20 kA

Protection level U

p

Core-Core / Core-Ground

 50 V (C3 - 10 A) / 

 650 V (C1 - 500 V / 250 A)

 50 V (C3 - 10 A) / 

 650 V (C1 - 500 V / 250 A)

Cut-off frequency fg (3 dB)

Symmetrical in the 50 

 system

typ. 6 MHz

typ. 6 MHz

Resistance per path

3.3 

3.3 

General data

Dimensions W/H/D

6.2 mm

 

/

 

93.1 mm

 

/

 

102.5 mm

6.2 mm

 

/

 

93 mm

 

/

 

102.5 mm

Connection data solid/stranded/AWG

0.14...2.5

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.14...2.5

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 26 ... 12

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

EN 61643-21 / EN 60079-0 / EN 60079-11 /

EN

 

61643-21/A2 / EN 60079-0 / EN 60079-11 /

EN 60079-26 / IEC 60079-0 / IEC 60079-11

EN 60079-26 / IEC 60079-0 / IEC 60079-11

Safety data

EC-type examination certificate according to ATEX

KEMA 09ATEX0051 X

KEMA 09ATEX0051 X

Identification according to ATEX

 II 1 G Ex ia IIC T4...T6

 II 1 D Ex iaD 20 T85°C...135°C

 II 1 G Ex ia IIC T4...T6

 II 1 D Ex iaD 20 T85°C...135°C

Maximum internal capacitance C

i

typ. 1.3 nF

1.3 nF

Maximum internal inductance L

i

< 1 µH

< 1 µH

Maximum input current I

i

350 mA (T4 / 

 80°C)

350 mA (T4 / 

 80°C)

Maximum input voltage U

i

36 V DC

36 V DC

Maximum input power P

i

3 W

3 W

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

LINETRAB

24 V DC

LIT 1X2-24

2804610

10

LIT 2X2-24

2804623

10

Accessories

Accessories

System adapter

, for MINI Analog modules with screw connection

MINI MCR-SL-V8-FLK 16-A

2811268

1

VARIOFACE system cable

 for connecting LIT and MINI Analog 

via system adapter

Cable length: 2 m

VIP-CAB-FLK16/FR/FR/0,14/2,0M

2900156

1

Cable length: 1 m

VIP-CAB-FLK16/FR/FR/0,14/1,0M

2900155

1

Cable length: 0.5 m

VIP-CAB-FLK16/FR/FR/0,14/0,5M

2900154

1

100

PHOENIX CONTACT

– Protection of up to four signal wires with 

an overall width of 6.2 mm

– Can be used in binary, analog, and 

intrinsically safe circuits

Current loops and analog signals
LINETRAB LIT

Surge protection and interference suppression filters

Surge protection for MCR technology

Double wire (loop), floating, 

e.g., for 4 ... 20

 

mA current loops  

2 double wires (loops), floating, 

e.g., for 4 ... 20

 

mA current loops  

phoenixcontact-protection-html.html
background image

IN

OU

T

B

K

B

N

1

B

L

2

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Electrical data

Maximum continuous operating voltage U

C

40 V DC / 28 V AC

Rated current

450 mA (55°C)

Pulse discharge current I

imp

 (10/350) µs

1 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 10 kA

Maximum permitted short-circuit current at installation location

1 A

Total discharge current I

total 

(8/20)

 

µs

20 kA

Max. discharge current I

max.

 (8/20) µs

10 kA

Protection level U

p

Core-Core

 80 V (C2 - 5 kA)

Core-Ground

 450 V (C2 - 5 kA / direct grounding)

Output voltage limitation at 1 kV/µs

Core-Core / Core-Ground

 55 V / 

 450 V (Direct grounding)

Resistance per path

2.2 

General data

Dimensions W/H/D

34 mm

 

/

 

34 mm

 

/

 

137 mm

Temperature range

-40 °C ... 85 °C

Test standards

IEC 61643-21

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

SURGETRAB,

 protective adapter for installation on measuring 

sensors

Outer thread: M20 x 1.5

24 V DC

S-PT-1X2-24DC

2880668

1

Outer thread: 1/2'' 14 NPT

24 V DC

S-PT-1X2-24DC-1/2"

2882569

1

Outer thread:  3/4'' 14 NPT

24 V DC

S-PT-1X2-24DC-3/4"

2882598

1

101

PHOENIX CONTACT

– Easy assembly, directly on the field device
– Arresters in hexagonal tube with various 

outer threads

S-PT-1x2...

 installation in the signal path 

feed-through

Notes:

For more information about EX approvals, visit  

phoenixcontact.com

For additional safety data, visit phoenixcontact.net/products

Current loops and analog signals
SURGETRAB S-PT

Surge protection and interference suppression filters

Surge protection for MCR technology

Double wire (loop), floating, 

e.g., for 4 ... 20

 

mA current loops  

phoenixcontact-protection-html.html
background image

IN

OU

T

1

2

2'

1'

 

Technical data

Electrical data

... 12DC

... 24DC

... 60DC

IEC test classification/EN type

B2 / C1 / C2 / 

C3 / D1

B2 / C1 / C2 / 

C3 / D1

B2 / C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

± 15 V DC / 

10 V AC

± 30 V DC / 

21 V AC

60 V DC / 

50 V AC

Rated current

380 mA AC 

(25 °C)

380 mA AC 

(25 °C)

380 mA AC

(25 °C)

Pulse discharge current I

imp

 (10/350) µs

1 kA

1 kA

1 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

5 kA / 5 kA

5 kA / 5 kA

5 kA / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

10 kA

10 kA

Protection level U

p

Core-Core

 25 V (C3, 

7.5 kV/100 A)

 45 V (C3, 

7.5 kV/100 A)

 160 V (C3 - 100 A)

Core-Ground

 700 V (C3, 

7.5 kV/100 A)

 700 V (C3, 

7.5 kV/100 A)

 700 V (C3 - 100 A)

Cut-off frequency fg (3 dB)

Symmetrical/asymmetrical in the 100 

 system

1.2 MHz / -

2.7 MHz / -

typ. 2 MHz / -

Resistance per path

3.3 

3.3 

3.3 

General data

Dimensions W/H/D

9.5 mm

 

/

 

21 mm

 

/

 

53.5 mm

Temperature range

-25 °C ... 75 °C

Test standards

IEC 61643-21

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

COMTRAB modular

12 V DC

CTM 1X2- 12DC

2838597

10

24 V DC

CTM 1X2- 24DC

2838513

10

60 V DC

CTM 1X2- 60DC

2838568

10

Accessories

Magazine

, with grounding rail for accommodating up to 

10 LSA-PLUS protective plugs (CTM...), for insertion in 

CT-TERMIBLOCK or LSA-PLUS disconnect strip

CTM 10-MAG

2838610

5

Grounding connector

CTM EST

2838649

10

Screw terminal block,

 with disconnect contacts for 

accommodating the CT and CTM protective plugs, design: 

10 double wires

CT-TERMIBLOCK 10 DA

0441711

10

102

PHOENIX CONTACT

– Space-saving LSA-PLUS connection 

technology

– Can be used in LSA-PLUS disconnect and 

control strips or CT-TERMIBLOCK

– The CTM 10-MAG surge protection 

magazine can be fitted with ten different 
protective plugs

Current loops and analog signals
COMTRAB CTM

Surge protection and interference suppression filters

Surge protection for MCR technology

Double wire (loop), floating

phoenixcontact-protection-html.html
background image

10...

3

6

V DC

+

-

1

2

4

5

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Electrical data

IEC test classification/EN type

Maximum continuous operating voltage U

C

-

Rated current

-

General data

Dimensions W/H/D

6.2 mm

 

/

 

105.8 mm

 

/

 

83.5 mm

Temperature range

-40 °C ... 60 °C

Test standards

EN 61000-6-2 / EN 61000-6-3

Remote indication contact

N/C contact

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Max. operating voltage

24 V AC / 36 V DC

Max. operating current

500 mA AC (peak) / 500 mA DC

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Remote signaling set

Screw connection technology

TTC-6-FMRS-UT

2907810

1

Push-in connection technology

TTC-6-FMRS-PT

2907811

1

103

PHOENIX CONTACT

– Overall width of just 2 x 6.2 mm
– With Push-in or screw connection 

technology

– Floating remote indication contact
– Visual status indicator on the module
– Monitors up to 40 neighboring SPDs
– No  SPD  wiring  necessary
– No programming necessary

H

W

D

new

Remote signaling set
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

Transceiver module for remote signaling of 

TTC-6...-I products

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

4

5

6

1

2

3

unprotected

protected

U

U

Technical data

Technical data

Electrical data

... 12DC

... 24DC

... 48DC

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

15 V DC

30 V DC

53 V DC

30 V DC

Rated current

600 mA (40°C)

600 mA (40°C)

220 mA (75°C)

600 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

0.5 kA

0.5 kA

0.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

- / 5 kA

- / 5 kA

- / 5 kA

- / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

10 kA

10 kA

10 kA

Protection level U

p

Core-Core

-

-

-

-

Core-Ground

 25 V (C3 - 

25 A)

 45 V (C3 - 

25 A)

 80 V (C3 - 

25 A)

 45 V (C3 - 

25 A)

Cut-off frequency fg (3 dB)

Asymmetrical in the 150 

 system

typ. 440 kHz

typ. 960 kHz

typ. 1.7 MHz

typ. 960 kHz

Resistance per path

1.65 

1.65 

1.65 

1.65 

General data

Dimensions W/H/D

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TERMITRAB complete, 

with screw connection technology

12 V DC

TTC-6P-2X1-12DC-UT-I

2908201

1

24 V DC

TTC-6P-2X1-24DC-UT-I

2906810

1

TTC-6P-2X1-M-24DC-UT-I

2906741

1

48 V DC

TTC-6P-2X1-48DC-UT-I

2908203

1

TERMITRAB complete,

 with Push-in connection technology

12 V DC

TTC-6P-2X1-12DC-PT-I

2908202

1

24 V DC

TTC-6P-2X1-24DC-PT-I

2906816

1

TTC-6P-2X1-M-24DC-PT-I

2906753

1

48 V DC

TTC-6P-2X1-48DC-PT-I

2908204

1

Accessories

Accessories

Remote signaling set

Screw connection technology

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-UT

2907810

1

Push-in connection technology

TTC-6-FMRS-PT

2907811

1

TTC-6-FMRS-PT

2907811

1

104

PHOENIX CONTACT

– Pluggable surge protection
– Overall width of just 6.2 mm
– With Push-in or screw connection 

technology

– Integrated mechanical status indicator
– Impedance-neutral insertion and removal
– Coded connector versions
– With knife disconnection as an option
– Optional remote signaling module 

monitors up to 40 items, without 
additional wiring

– Plugs can be tested with 

CHECKMASTER 2

Digital signals and switching contacts
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

2-conductor with common reference potential, 

3/6 connection grounded directly, e.g.,

 

for 

binary signals

2-conductor with common reference potential, 

3/6 connection grounded directly, with knife 

disconnection, e.g.,

 

for binary signals

new

new

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

4

5

6

1

2

3

unprotected

protected

U

U

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

... 12DC

... 48DC

... 24DC

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

15 V DC

53 V DC

30 V DC

600 mA (40°C)

220 mA (75°C)

600 mA (40°C)

0.5 kA

0.5 kA

0.5 kA

- / 5 kA

- / 5 kA

- / 5 kA

10 kA

10 kA

10 kA

-

-

-

 1.2 kV (C3 - 

25 A)

 800 V (C3 - 

25 A)

 1.1 kV (C3 - 

25 A)

-

-

-

1.65 

1.65 

1.65 

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-40 °C ... 85 °C

-40 °C ... 85 °C

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TTC-6P-2X1-F-12DC-UT-I

2908205

1

TTC-6P-2X1-F-M-24DC-UT-I

2906784

1

TTC-6P-2X1-F-48DC-UT-I

2908208

1

TTC-6P-2X1-F-12DC-PT-I

2908206

1

TTC-6P-2X1-F-M-24DC-PT-I

2906794

1

TTC-6P-2X1-F-48DC-PT-I

2908209

1

Accessories

Accessories

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-PT

2907811

1

TTC-6-FMRS-PT

2907811

1

105

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

2-conductor with common reference potential, 

3/6 connection grounded via gas-filled surge 

arrester, e.g.,

 

for binary signals

2-conductor with common reference potential, 3/6 

connection grounded via gas-filled surge arrester, 

with knife disconnection, e.g.,

 

for binary signals

new

new

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

4

5

6

1

2

3

unprotected

protected

U

U

Technical data

Technical data

Electrical data

... 24DC

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

30 V DC

30 V DC

Rated current

6 A (40°C)

6 A (40°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

0.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

0.5 kA / 5 kA

0.5 kA / 5 kA

Total discharge current I

total 

(8/20)

 

µs

5 kA

5 kA

Protection level U

p

Core-Core

 45 V (C3 - 25 A)

 45 V (C3 - 25 A)

Core-Ground

 850 V (C3 - 25 A)

 850 V (C3 - 25 A)

Cut-off frequency fg (3 dB)

Symmetrical in the 150 

 system

typ. 1 MHz

typ. 1 MHz

Resistance per path

100 m

100 m

General data

Dimensions W/H/D

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

6.2 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TERMITRAB complete, 

with screw connection technology

24 V DC

TTC-6P-2-HC-24DC-UT-I

2906811

1

TTC-6P-2-HC-M-24DC-UT-I

2906743

1

TERMITRAB complete,

 with Push-in connection technology

24 V DC

TTC-6P-2-HC-24DC-PT-I

2906817

1

TTC-6P-2-HC-M-24DC-PT-I

2906755

1

Accessories

Accessories

Remote signaling set

Screw connection technology

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-UT

2907810

1

Push-in connection technology

TTC-6-FMRS-PT

2907811

1

TTC-6-FMRS-PT

2907811

1

106

PHOENIX CONTACT

– One-piece or pluggable surge protection
– Overall width of just 6.2 mm
– With Push-in or screw connection 

technology

– Integrated mechanical status indicator
– Impedance-neutral insertion and removal
– Coded connector versions
– With knife disconnection as an option
– Optional remote signaling module 

monitors up to 40 items, without 
additional wiring

– Plugs can be tested with 

CHECKMASTER 2

Digital signals and switching contacts
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

2-conductor, floating, pluggable, 

e.g.,

 

for actuator circuits

2-conductor, floating, pluggable, with knife 

disconnection, e.g.,

 

for actuator circuits

new

new

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

4

5

6

1

2

3

unprotected

protected

U

U

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

... 24DC

... 24DC

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

30 V DC

30 V DC

6 A (40°C)

6 A (40°C)

0.5 kA

0.5 kA

0.5 kA / 5 kA

0.5 kA / 5 kA

5 kA

5 kA

 45 V (C3 - 25 A)

 45 V (C3 - 25 A)

 850 V (C3 - 25 A)

 850 V (C3 - 25 A)

typ. 1 MHz

typ. 1 MHz

100 m

100 m

100 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

83.5 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

83.5 mm

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TTC-6-2-HC-24DC-UT-I

2908438

1

TTC-6-2-HC-M-24DC-UT-I

2906719

1

TTC-6-2-HC-24DC-PT-I

2908439

1

TTC-6-2-HC-M-24DC-PT-I

2906731

1

Accessories

Accessories

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-PT

2907811

1

TTC-6-FMRS-PT

2907811

1

107

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

2-conductor, floating, one-piece, 

e.g.,

 

for actuator circuits

2-conductor, floating, one-piece, with knife 

disconnection, e.g.,

 

for actuator circuits

H

W

D

new

H

W

D

new

phoenixcontact-protection-html.html
background image

U

U

4

5

6

1

2

3

unprotected

protected

4

5

6

1

2

3

unprotected

protected

Technical data

Technical data

Electrical data

... 24DC

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

30 V DC

30 V DC

Rated current

600 mA (40°C)

600 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

0.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

- / 5 kA

- / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

10 kA

Protection level U

p

Core-Core

-

-

Core-Ground

 45 V (C3 - 25 A)

 1.1 kV (C3 - 25 A)

Cut-off frequency fg (3 dB)

Asymmetrical in the 150 

 system

typ. 960 kHz

-

Resistance per path

1.65 

1.65 

General data

Dimensions W/H/D

6.2 mm

 

/

 

105.8 mm

 

/

 

69.5 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

83.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TERMITRAB complete, 

with screw connection technology

Without status indicator

24 V DC

TTC-6-2X1-24DC-UT

2906799

1

With status indicator

24 V DC

TTC-6-2X1-M-24DC-UT-I

2906716

1

TTC-6-2X1-F-M-24DC-UT-I

2906767

1

TERMITRAB complete,

 with Push-in connection technology

Without status indicator

24 V DC

TTC-6-2X1-24DC-PT

2906805

1

With status indicator

24 V DC

TTC-6-2X1-M-24DC-PT-I

2906729

1

TTC-6-2X1-F-M-24DC-PT-I

2906776

1

Accessories

Accessories

Remote signaling set

Screw connection technology

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-UT

2907810

1

Push-in connection technology

TTC-6-FMRS-PT

2907811

1

TTC-6-FMRS-PT

2907811

1

108

PHOENIX CONTACT

– Overall width of just 6.2 mm
– With Push-in or screw connection 

technology

– With integrated mechanical status 

indicator and knife disconnection as an 
option

– Optional remote signaling module 

monitors up to 40 items, without 
additional wiring

H

W

D

new

H

W

D

new

Digital signals and switching contacts
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

2-conductor with common reference potential, 3/6 connection 

grounded via gas-filled surge arrester, with or without status 

indicator and knife disconnection, e.g.,

 

for binary signals

2-conductor with common reference potential, 3/6 

connection grounded via gas-filled surge arrester, 

with knife disconnection, e.g.,

 

for binary signals

phoenixcontact-protection-html.html
background image

U

4

5

6

1

2

3

unprotected

protected

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Electrical data

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

30 V DC

Rated current

250 mA (70°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

- / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

Protection level U

p

Core-Core

-

Core-Ground

 50 V (C3 - 30 A)

Cut-off frequency fg (3 dB)

Asymmetrical in the 150 

 system

-

Resistance per path

2.2 

General data

Dimensions W/H/D

3.5 mm

 

/

 

106 mm

 

/

 

69.5 mm

Connection data solid/stranded/AWG

0.2...1.5

 

mm²

 

/ 0.2...1.5

 

mm²

 

/ 24 ... 16

Temperature range

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

TERMITRAB complete,

 with Push-in connection technology

24 V DC

TTC-3-2X1-24DC-PT

2907326

1

Accessories

End cover

TTC-3-LCP

2908843

1

109

PHOENIX CONTACT

– Overall width of just 3.5 mm
– With Push-in connection technology

H

W

D

new

Digital signals and switching contacts
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

2-conductor with common reference potential, 

e.g.,

 

for binary signals

phoenixcontact-protection-html.html
background image

5

1

3

6

2

4

12

1

0

8

FM

FM

DC

 +

DC

Powe

r

S

P

D

DC

 +

DC

DC

FM

7

11

9

3

8

12

1

0

4

protected

unprotected

U

 

 

 

Technical data

Technical data

Electrical data

... 24DC

... 48DC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 

Maximum continuous operating voltage U

C

-

30 V DC / 21 V AC

53 V DC / 37 V AC

30 V DC / 21 V AC

53 V DC / 37 V AC

30 V DC / 21 V AC

53 V DC / 37 V AC

30 V DC / 21 V AC

53 V DC

Rated current

-

1000 mA (40°C)

300 mA

1000 mA (40°C)

300 mA

700 mA (50 °C)

300 mA

700 mA (50 °C)

300 mA

Pulse discharge current I

imp

 (10/350) µs

-

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

- / -

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

Total discharge current I

total 

(8/20)

 

µs

-

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

Protection level U

p

Core-Ground

-

 55 V (C3 - 25 A)

 90 V (C3 - 25 A)

Resistance per path

-

1.2 

1.2 

General data

PT-IQ...UT dimensions W/H/D

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

17.7 mm

PT-IQ...PT dimensions W/H/D

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

17.7 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

Temperature range

-40 °C ... 70 °C

-40 °C ... 70 °C

Test standards

EN 61000-6-2 / EN 61000-6-3 / EN 60950-1 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-3 /

IEC 61643-21 / EN 61643-21 /

EN 60079-0 / EN 60079-11 / EN 60079-15

EN 61000-6-2

Remote indication contact

2x N/C contacts

Via TBUS

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 14

-

 

mm²

 

/ -

 

mm²

 

/ -

Max. operating voltage

30 V AC (50/60 Hz, non-Ex) / 50 V DC (non-Ex)

-

Max. operating current

1 A (up to 50°C, non-Ex)

-

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PLUGTRAB, 

supply and remote signaling module

Screw connection technology

PT-IQ-PTB-UT

2800768

1

Push-in connection technology

PT-IQ-PTB-PT

2801296

1

PLUGTRAB,

 with screw connection technology

24 V DC

PT-IQ-2X1-24DC-UT

2800787

1

48 V DC

PT-IQ-2X1-48DC-UT

2800789

1

PLUGTRAB,

 with Push-in connection technology

24 V DC

PT-IQ-2X1-24DC-PT

2801247

1

48 V DC

PT-IQ-2X1-48DC-PT

2801249

1

110

PHOENIX CONTACT

– Multi-stage status monitoring
– Group message via supply and remote 

signaling module

– Multi-stage, floating remote signaling
– System supplied via DIN rail bus
– Up to 28 protection modules per supply 

module

– Maximum ease of maintenance thanks to 

the two-piece design

– Plugs  are  coded
– Impedance-neutral disconnection of plug 

for maintenance purposes

– PT-IQ... base element with Push-in or 

screw connection technology

– Base element remains an integral part of 

the installation

– Corresponding replacement plugs can be 

found on our website

Digital signals and switching contacts
PLUGTRAB PT-IQ

Surge protection and interference suppression filters

Surge protection for MCR technology

Supply and remote signaling module

2-wire with common reference potential, 

connection 9/10 grounded directly, 

e.g., for binary signals

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

7

11

9

3

8

12

1

0

4

protected

unprotected

protected

unprotected

1

5

7

11

9

3

2

6

8

12

1

0

4

protected

unprotected

1

5

7

11

9

3

2

6

8

12

1

0

4

U

U

U

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

Technical data

Technical data

Technical data

... 24DC

... 48DC

... 24DC

... 48DC

... 24DC

... 48DC

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

-

30 V DC / 21 V AC

53 V DC / 37 V AC

30 V DC / 21 V AC

53 V DC / 37 V AC

30 V DC / 21 V AC

53 V DC / 37 V AC

30 V DC / 21 V AC

53 V DC / 37 V AC

Rated current

-

1000 mA (40°C)

300 mA

1000 mA (40°C)

300 mA

700 mA (50 °C)

300 mA

700 mA (50 °C)

300 mA

 (10/350) µs

-

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

Core-Core / Core-Ground

- / -

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

µs

-

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

 780 V (C3 - 25 A)

 850 V (C3 - 25 A)

 180 V (C2 - 10 kA)

 90 V (C3 - 25 A)

 780 V (C3 - 25 A)

 850 V (C3 - 25 A)

1.2 

1.2 

1.2 

1.2 

1.2 

1.2 

77.5 mm

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

77.5 mm

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-40 °C ... 70 °C

-40 °C ... 70 °C

-40 °C ... 70 °C

Test standards

EN 61000-6-2 / EN 61000-6-3 / EN 60950-1 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-3 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-3 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-3 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-3 /

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

Via TBUS

Via TBUS

Via TBUS

-

 

mm²

 

/ -

 

mm²

 

/ -

-

 

mm²

 

/ -

 

mm²

 

/ -

-

 

mm²

 

/ -

 

mm²

 

/ -

-

-

-

-

-

-

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PT-IQ-2X1+F-24DC-UT

2800788

1

PT-IQ-4X1-24DC-UT

2800982

1

PT-IQ-4X1+F-24DC-UT

2800983

1

PT-IQ-2X1+F-48DC-UT

2800790

1

PT-IQ-4X1-48DC-UT

2801219

1

PT-IQ-4X1+F-48DC-UT

2801220

1

PT-IQ-2X1+F-24DC-PT

2801248

1

PT-IQ-4X1-24DC-PT

2801271

1

PT-IQ-4X1+F-24DC-PT

2801272

1

PT-IQ-2X1+F-48DC-PT

2801250

1

PT-IQ-4X1-48DC-PT

2801273

1

PT-IQ-4X1+F-48DC-PT

2801274

1

111

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

H

W

D

2-wire with common reference potential, 

connection 9/10 grounded via gas-filled surge 

arrester, e.g., for binary signals

4-wire with common reference potential, 

connection 9/10 grounded directly, 

e.g., for binary signals

4-wire with common reference potential, 

connection 9/10 grounded via gas-filled surge 

arrester, e.g., for binary signals

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

*

IN

OU

T

8

7

1

0

9

12

11

4

3

U

 

Ex: 

Technical data

Electrical data

... 5DC

... 12DC

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / 

Maximum continuous operating voltage U

C

6 V DC / 

4 V AC

13 V DC / 

9 V AC

28 V DC / 

20 V AC

Rated current

300 mA (45°C)

300 mA (45°C)

300 mA (45°C)

300 mA (45°

Pulse discharge current I

imp

 (10/350) µs

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

Max. discharge current I

max.

 (8/20) µs

10 kA

10 kA

10 kA

10 kA

10 kA

10 kA

10 kA

10 kA

10 kA

10 kA

10 kA (per path)

Output voltage limitation at 1 kV/µs

Core-Ground

 10 V

 18 V

 40 V

Cut-off frequency fg (3 dB)

Symmetrical/asymmetrical in the 50 

 system

- / typ. 1 MHz

- / typ. 3 MHz

- / typ. 4.5 MHz

- / typ. 4 MHz

- / typ. 8 MHz

- / typ. 1 MHz

- / typ. 3 MHz

- / typ. 6 MHz

- / ty

Resistance per path

4.7 

4.7 

4.7 

General data

Dimensions W/H/D

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

Temperature range

-40 °C ... 85 °C

Test standards

IEC 61643-21

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

PLUGTRAB plug,

 with protective circuit for plugging into the PT 

base element

5 V DC

PT 2X1- 5DC-ST

2856061

10

12 V DC

PT 2X1-12DC-ST

2856074

10

24 V DC

PT 2X1-24DC-ST

2856087

10

48 V DC

12 V AC

24 V AC

48 V AC

PLUGTRAB base element,

 for mounting on NS

 

35

with bridge between the connections 3/4 (

) and 9/10

PT 2X1-BE

2856139

10

with gas-filled surge arrester between the connections 3/4 (

) and 

9/10

PT 2X1+F-BE

2856142

10

Accessories

Shield fast connection

For Ø 3-6 mm

SSA 3-6

2839295

10

For Ø 5-10 mm

SSA 5-10

2839512

10

112

PHOENIX CONTACT

Digital signals and switching contacts
PLUGTRAB PT

– Consistently pluggable signal circuit 

protection

– Maximum ease of maintenance thanks to 

the two-piece design

– Base element remains an integral part of 

the installation

– Impedance-neutral disconnection of plug 

for test and maintenance purposes

– Plugs can be checked with 

CHECKMASTER

* Note:

Various grounding options for the base 
elements:

PT .x.-BE

 connections 9/10 (GND) 

directly connected to the mounting foot.

PT .x.+F-BE

 connections 9/10 (GND) 

connected to the mounting foot via a gas-
filled surge arrester.

Surge protection and interference suppression filters

Surge protection for MCR technology

H

W

D

Notes:

For approvals and dimensional drawing, visit 

phoenixcontact.net/products

2-wire, with common reference potential, 

e.g., for binary signals

phoenixcontact-protection-html.html
background image

*

IN

OU

T

8

7

1

0

9

12

11

4

3

*

IN

OU

T

2

1

1

0

9

8

7

12

11

6

5

4

3

*

IN

OU

T

2

1

1

0

9

8

7

12

11

6

5

4

3

U

U

U

For further information and full technical data, visit phoenixcontact.net/products

 

Ex: 

 

Ex: 

 

Ex: 

Technical data

Technical data

Technical data

... 12AC

... 24AC

... 5DC

... 12DC

... 24DC

... 48DC

... 24AC

... 48AC

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

18 V DC / 

13 V AC

40 V DC / 

28 V AC

6 V DC

 

/

4 V AC

13 V DC

 

/

9 V AC

28 V DC

 

/

20 V AC

53 V DC

 

/

37 V AC

40 V DC / 

28 V AC

77 V DC / 

55 V AC

Rated current

300 mA (45°C)

300 mA (45°C)

300 mA (45°C)

300 mA (45°C)

300 mA (45°C)

300 mA (45°C)

300 mA (45°C)

300 mA (45°C)

300 mA (45°C)

300 mA (45°C)

300 mA (45°C)

 (10/350) µs

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

Core-Core / Core-Ground

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

- / 10 kA

µs

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

 (8/20) µs

10 kA

10 kA

10 kA

10 kA

10 kA

10 kA

10 kA

10 kA

10 kA

10 kA

10 kA (per path)

 25 V

 55 V (with PT 2x1-BE)

 10 V

 18 V

 40 V

 70 V

 55 V

-

 system

- / typ. 1 MHz

- / typ. 3 MHz

- / typ. 4.5 MHz

- / typ. 4 MHz

- / typ. 8 MHz

- / typ. 1 MHz

- / typ. 3 MHz

- / typ. 6 MHz

- / typ. 9 MHz

- / typ. 8 MHz

- / typ. 10 MHz

4.7 

4.7 

4.7 

4.7 

4.7 

4.7 

4.7 

4.7 

65.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-

 

mm²

 

/ -

 

mm²

 

/ -

-40 °C ... 85 °C

-40 °C ... 85 °C

-40 °C ... 85 °C

IEC 61643-21

IEC 61643-21

IEC 61643-21

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PT 4X1- 5DC-ST

2838306

10

PT 4X1-12DC-ST

2838319

10

PT 4X1-24DC-ST

2838322

10

PT 4X1-48DC-ST

2858014

10

PT 2X1-12AC-ST

2856090

10

PT 2X1-24AC-ST

2856100

10

PT 4X1-24AC-ST

2838351

10

PT 4X1-48AC-ST

2804856

10

PT 2X1-BE

2856139

10

PT 4X1-BE

2839363

10

PT 4X1-BE

2839363

10

PT 2X1+F-BE

2856142

10

PT 4X1+F-BE

2839376

10

PT 4X1+F-BE

2839376

10

Accessories

Accessories

Accessories

SSA 3-6

2839295

10

SSA 3-6

2839295

10

SSA 3-6

2839295

10

SSA 5-10

2839512

10

SSA 5-10

2839512

10

SSA 5-10

2839512

10

113

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

H

W

D

2-wire, with common reference potential, 

e.g., for binary signals

4-wire with common reference potential, 

connection 9/10 grounded directly, 

e.g., for binary signals

4-wire with common reference potential, 

connection 9/10 grounded via gas-filled surge 

arrester, e.g., for binary signals

phoenixcontact-protection-html.html
background image

U

U

1

3

5

2

4

6

12

11

*

IN

OU

T

2(+)

1(+)

6(+)

5(+)

J

J

3(-)

4(-)

J

11

12

Technical data

Technical data

Electrical data

... 120AC

... 230AC

... 60AC

... 120AC

... 230AC

IEC test classification/EN type

C1 / C2 / C3

C1 / C2 / C3 / D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

- / 175 V AC

- / 250 V AC

100 V DC

 

/

75 V AC 

(50/60 Hz)

150 V DC

 

/

150 V AC 

(50/60 Hz)

275 V DC

 

/

275 V AC 

(50/60 Hz)

Rated current

6 A

6 A

26 A AC 

(30 °C)

26 A AC 

(30 °C)

26 A AC 

(30 °C)

Pulse discharge current I

imp

 (10/350) µs

300 A

500 A

500 A

500 A

500 A

Nominal discharge current I

n

 (8/20) µs

Core-Ground

3 kA

3 kA

2 kA

2.5 kA

2.5 kA

Total discharge current I

total 

(8/20)

 

µs

8 kA

8 kA

4 kA

5 kA

5 kA

Output voltage limitation at 1 kV/µs

Core-Ground

 800 V

 1.4 kV

 200 V

 380 V

 650 V

General data

Dimensions W/H/D

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 80 °C

-40 °C ... 85 °C

Test standards

EN 61643-21

IEC 61643-21/A2 / EN

 

61643-21/A2

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

MAINS-PLUGTRAB,

 consisting of a plug and a base element

120 V AC

PT 2X1-VF-120AC

2859327

10

230 V AC

PT 2X1-VF-230AC

2805460

10

PLUGTRAB plug,

 with protective circuit for plugging into the PT 

base element

60 V AC

PT 2X1VA- 60AC-ST

2839172

10

120 V AC

PT 2X1-VF-120AC-ST

2856799

10

PT 2X1VA-120AC-ST

2839185

10

230 V AC

PT 2X1-VF-230AC-ST

2921365

10

PT 2X1VA-230AC-ST

2839198

10

PLUGTRAB base element,

 for mounting on NS

 

35

PT-BE/FM

2839282

10

PT-BE/FM

2839282

10

Accessories

Accessories

Shield fast connection

For Ø 3-6 mm

SSA 3-6

2839295

10

SSA 3-6

2839295

10

For Ø 5-10 mm

SSA 5-10

2839512

10

SSA 5-10

2839512

10

114

PHOENIX CONTACT

– Protective devices for higher nominal 

power

– Consistently pluggable signal circuit 

protection

– Maximum ease of maintenance thanks to 

the two-piece design

– Base element remains an integral part of 

the installation

– Impedance-neutral disconnection of plug 

for test and maintenance purposes

– Plugs can be checked with 

CHECKMASTER

– FM types with permanent and 

independent monitoring by a diagnostics 
unit

* Note:

 If no protective plug is inserted, 

there is no electrical connection.

H

W

D

H

W

D

Digital signals and switching contacts
PLUGTRAB PT

Surge protection and interference suppression filters

Surge protection for MCR technology

2-wire, floating, free of leakage current, 

e.g., for actuator circuits

2-wire, with common reference potential, 

remote signaling, e.g., for actuator circuits

phoenixcontact-protection-html.html
background image

U

U

IN

OU

T

2

1

6

5

4

3

IN

OU

T

2

1

6

5

8

7

12

11

1

0

9

4

3

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

60 V DC / 48 V AC

60 V DC / 120 V AC

Rated current

2 A AC (80 °C)

2 A AC (80 °C)

Pulse discharge current I

imp

 (10/350) µs

5 kA

2.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

- / 20 kA

10 kA / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

20 kA

Protection level U

p

Core-Ground

 600 V (C2 - 10 kV / 5 kA)

 450 V (C2 - 10

 

kV / 5

 

kA with PT 4-BE)

Output voltage limitation at 1 kV/µs

Core-Ground

 600 V

 450 V (with PT 4-BE)

General data

Dimensions W/H/D

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PLUGTRAB plug,

 with protective circuit for plugging into the PT 

base element

48 V AC

PT 2-F-ST

2859000

10

110 V AC

PT 4-F-ST

2858441

10

PLUGTRAB base element,

 for mounting on NS

 

35

PT-BE/FM

2839282

10

Bridge between 3/4 (

) and 9/10

PT 4-BE

2839402

10

Accessories

Accessories

Shield fast connection

For Ø 3-6 mm

SSA 3-6

2839295

10

SSA 3-6

2839295

10

For Ø 5-10 mm

SSA 5-10

2839512

10

SSA 5-10

2839512

10

115

PHOENIX CONTACT

– For systems with high dielectric strength 

or fine protection installed

– Installation location - directly where the 

MCR cable enters the building

– Consistently pluggable signal circuit 

protection

– Maximum ease of maintenance thanks to 

the two-piece design

– Base element remains an integral part of 

the installation

– Impedance-neutral disconnection of plug 

for test and maintenance purposes

– Plugs can be checked with 

CHECKMASTER

H

W

D

Digital signals and switching contacts
PLUGTRAB PT

Surge protection and interference suppression filters

Surge protection for MCR technology

2-wire, coarse protection, 

e.g., for actuator circuits

4-wire, coarse protection, 

e.g., for actuator circuits

phoenixcontact-protection-html.html
background image

U

*

IN

OU

T

2

1

6

5

8

7

12

11

1

0

9

4

3

Technical data

Electrical data

... 5DC

... 12DC

... 24DC

... 24AC

IEC test classification/EN type

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

Maximum continuous operating voltage U

C

6 V DC  / 

4 V AC

12.8 V DC / 

9 V AC

27 V DC / 

19 V AC

40 V DC / 

28 V AC

Rated current

2 A (80 °C)

2 A (80 °C)

2 A (80 °C)

2 A AC (80 °C)

Pulse discharge current I

imp

 (10/350) µs

2.5 kA

2.5 kA

2.5 kA

2.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

720 A / 10 kA

690 A / 10 kA

365 A / 10 kA

187 A / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

20 kA

20 kA

20 kA

Max. discharge current I

max.

 (8/20) µs

10 kA

10 kA

10 kA

10 kA

Output voltage limitation at 1 kV/µs

Core-Core

 10 V

 18 V

 40 V

 75 V

Core-Ground

 450 V

 450 V

 450 V (with 

PT 4-BE)

 450 V (with 

PT 4-BE)

General data

Dimensions W/H/D

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

Test standards

IEC 61643-21

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

PLUGTRAB plug,

 with protective circuit for plugging into the PT 

base element

5 V DC

PT 4- 5DC-ST

2839211

10

12 V DC

PT 4-12DC-ST

2839237

10

24 V DC

PT 4-24DC-ST

2839240

10

24 V AC

PT 4-24AC-ST

2800078

1

PLUGTRAB base element,

 for mounting on NS

 

35

Bridge between 3/4 (

) and 9/10

PT 4-BE

2839402

10

Gas-filled surge arrester between 3/4 (

) and 9/10

PT 4+F-BE

2839415

10

Accessories

Shield fast connection

For Ø 3-6 mm

SSA 3-6

2839295

10

For Ø 5-10 mm

SSA 5-10

2839512

10

116

PHOENIX CONTACT

– Consistently pluggable signal circuit 

protection

– Maximum ease of maintenance thanks to 

the two-piece design

– Base element remains an integral part of 

the installation

– Impedance-neutral disconnection of plug 

for test and maintenance purposes

– Plugs can be checked with 

CHECKMASTER

* Note:

Various grounding options for the base 
elements:

PT .x.-BE

 connections 9/10 (GND) 

directly connected to the mounting foot.

PT .x.+F-BE

 connections 9/10 (GND) 

connected to the mounting foot via a gas-
filled surge arrester.

Digital signals and switching contacts
PLUGTRAB PT

Surge protection and interference suppression filters

Surge protection for MCR technology

4-wire, floating, impedance-free, 

e.g., for temperature measurement

phoenixcontact-protection-html.html
background image

U

U

7

5

8

6

OU

T

IN

3

1

4

2

7

5
3

1

8

6
4

OU

T

IN

2

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

Technical data

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

36 V DC / 25 V AC

36 V DC / 25 V AC

Rated current

350 mA (40°C)

350 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

500 A

500 A

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

- / 5 kA

- / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

20 kA

Max. discharge current I

max.

 (8/20) µs

20 kA (Total)

10 kA

Protection level U

p

Core-Core / Core-Ground

- / 

 60 V (C1 - 500 V / 250 A)

- / 

 60 V (C1 - 500 V / 250 A)

Cut-off frequency fg (3 dB)

Asymmetrical in the 50 

 system

typ. 6 MHz

typ. 6 MHz

Resistance per path

3.3 

3.3 

General data

Dimensions W/H/D

6.2 mm

 

/

 

93 mm

 

/

 

102.5 mm

6.2 mm

 

/

 

93 mm

 

/

 

102.5 mm

Connection data solid/stranded/AWG

0.14...2.5

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 26 ... 12

0.14...2.5

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 26 ... 12

Temperature range

-40 °C ... 80 °C

-40 °C ... 80 °C

Test standards

IEC 61643-21 / DIN EN 61643-21

IEC 61643-21 / DIN EN 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

LINETRAB

 

LIT surge protection

24 V DC

LIT 2X1-24

2804636

10

LIT 4X1-24

2804649

10

117

PHOENIX CONTACT

– Protection of up to four signal wires with 

an overall width of 6.2 mm

– Can be used in binary, analog, and 

intrinsically safe circuits

Notes:

For approvals and dimensional drawing, visit 

phoenixcontact.net/products

H

W

D

H

W

D

Digital signals and switching contacts
LINETRAB LIT

Surge protection and interference suppression filters

Surge protection for MCR technology

Protection for two conductors with a common 

reference potential

Protection for four conductors with a common 

reference potential

phoenixcontact-protection-html.html
background image

U

B

N

RD

B

U

B

K

WH

+

+

˜

˜

˜

˜

Ex: 

 

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

36 V DC / 25 V AC

Pulse discharge current I

imp

 (10/350) µs

1 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

260 A / 10 kA

Maximum permitted short-circuit current at installation location

1 A (non-Ex)

Total discharge current I

total 

(8/20)

 

µs

20 kA

Protection level U

p

Core-Core

 65 V (C3 - 10 A)

Core-Ground

 1.1 kV (C3 - 100 A)

Output voltage limitation at 1 kV/µs

Core-Core / Core-Ground

 60 V / -

General data

Dimensions W/H/D

28 mm

 

/

 

28 mm

 

/

 

79 mm

Temperature range

-40 °C ... 80 °C (non-Ex)

Test standards

EN

 

61643-21/A2 / EN 60079-0 / EN 60079-1 /

EN 60079-11 / EN 60079-26 / EN

 

60079-31

Safety data

EC-type examination certificate according to ATEX

KEMA 09ATEX0028 X

Identification according to ATEX

 II 1 G Ex ia IIC T4...T6

 II 2 G Ex d IIC T4...T6

Maximum internal capacitance C

i

1.65 nF

Maximum internal inductance L

i

1 µH

Maximum input current I

i

500 mA (T4 / 

 75 °C)

Maximum input voltage U

i

36 V DC

Maximum input power P

i

3 W

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

SURGETRAB

 protective adapter for installation on measuring 

sensors for Ex protection zones

Outer thread: M20 x 1.5

24 V DC

S-PT-4-EX-24DC

2800036

1

Outer thread: 1/2'' 14 NPT

24 V DC

S-PT-4-EX-24DC-1/2"

2800037

1

118

PHOENIX CONTACT

– Easy assembly, directly on the field device
– Arresters in hexagonal tube with various 

outer threads

S-PT-4-EX

 installation in a separate 

cable gland parallel to the signal cables

Digital signals and switching contacts
SURGETRAB S-PT

Surge protection and interference suppression filters

Surge protection for MCR technology

4-wire with common reference potential, 

intrinsically safe, encapsulated, without 

decoupling resistance

phoenixcontact-protection-html.html
background image

U

IN

OUT

1

2

2'

1'

For further information and full technical data, visit phoenixcontact.net/products

 

Technical data

Electrical data

... 12DC

... 24DC

... 60DC

IEC test classification/EN type

B2 / C1 / C2 / 

C3 / D1

B2 / C1 / C2 / 

C3 / D1

B2 / C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

± 15 V DC / 

10 V AC

± 30 V DC / 

21 V AC

60 V DC / 

50 V AC

Rated current

380 mA AC 

(25 °C)

380 mA AC 

(25 °C)

380 mA AC

(25 °C)

Pulse discharge current I

imp

 (10/350) µs

1 kA

1 kA

1 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

- / 5 kA

- / 5 kA

- / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

10 kA

10 kA

Output voltage limitation at 1 kV/µs

Core-Core

-

-

-

Core-Ground

 22 V

 45 V

 160 V

Cut-off frequency fg (3 dB)

Symmetrical/asymmetrical in the 100 

 system

- / 1.5 MHz

- / 2.7 MHz

- / typ. 2 MHz

Resistance per path

3.3 

3.3 

3.3 

General data

Dimensions W/H/D

9.5 mm

 

/

 

21 mm

 

/

 

53.5 mm

Temperature range

-25 °C ... 75 °C

Test standards

IEC 61643-21

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

COMTRAB modular

, surge protection for a double wire with 

coarse and fine protection and ohmic decoupling, DSL-compatible

12 V DC

CTM 2X1- 12DC

2838584

10

24 V DC

CTM 2X1- 24DC

2838500

10

60 V DC

CTM 2X1- 60DC

2838542

10

Accessories

Magazine

, with grounding rail for accommodating up to 10 LSA-

PLUS protective plugs (CTM...), for insertion in CT-TERMIBLOCK 

or LSA-PLUS disconnect strip

CTM 10-MAG

2838610

5

Grounding connector

CTM EST

2838649

10

Screw terminal block,

 with disconnect contacts for 

accommodating the CT and CTM protective plugs, design: 10 

double wires

CT-TERMIBLOCK 10 DA

0441711

10

119

PHOENIX CONTACT

– Space-saving LSA-PLUS connection 

technology

– Can be used in LSA-PLUS disconnect and 

control strips or CT-TERMIBLOCK

– The CTM 10-MAG surge protection 

magazine can be fitted with ten different 
protective plugs

Digital signals and switching contacts
COMTRAB CTM

Surge protection and interference suppression filters

Surge protection for MCR technology

2-wire, with common reference potential

phoenixcontact-protection-html.html
background image

ϑ

4

5

6

1

2

3

unprotected

protected

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

30 V DC

Rated current

450 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

0.5 kA / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

Protection level U

p

Core-Core

 45 V (C3 - 25 A)

Core-Ground

 600 V (C3 - 25 A)

Cut-off frequency fg (3 dB)

Symmetrical in the 150 

 system

typ. 1.1 MHz

Resistance per path

100 m

General data

Dimensions W/H/D

6.2 mm

 

/

 

105.8 mm

 

/

 

69.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

TERMITRAB complete, 

with screw connection technology

24 V DC

TTC-6-2-24DC-UT

2906800

1

TERMITRAB complete,

 with Push-in connection technology

24 V DC

TTC-6-2-24DC-PT

2906806

1

120

PHOENIX CONTACT

– Overall width of just 6.2 mm
– With Push-in or screw connection 

technology

H

W

D

new

Resistance-dependent measurements
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

2-conductor, floating, impedance-free, 

e.g.,

 

for temperature measurement

phoenixcontact-protection-html.html
background image

*

IN

OU

T

2

1

6

5

8

7

12

11

1

0

9

4

3

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Electrical data

... 5DC

... 12DC

... 24DC

... 24AC

IEC test classification/EN type

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

Maximum continuous operating voltage U

C

6 V DC  / 

4 V AC

12.8 V DC / 

9 V AC

27 V DC / 

19 V AC

40 V DC / 

28 V AC

Pulse discharge current I

imp

 (10/350) µs

2.5 kA

2.5 kA

2.5 kA

2.5 kA

Rated current

2 A (80 °C)

2 A (80 °C)

2 A (80 °C)

2 A AC (80 °C)

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

720 A / 10 kA

690 A / 10 kA

365 A / 10 kA

187 A / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

20 kA

20 kA

20 kA

Max. discharge current I

max.

 (8/20) µs

10 kA

10 kA

10 kA

10 kA

Output voltage limitation at 1 kV/µs

Core-Core

 10 V

 18 V

 40 V

 75 V

Core-Ground

 450 V

 450 V

 450 V (with 

PT 4-BE)

-

General data

Dimensions W/H/D

17.7 mm / 90 mm / 65.5 mm

Connection data

Solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

Test standards

IEC 61643-21 / DIN EN 61643-21 / UL 497B

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

PLUGTRAB plug,

 with protective circuit for plugging into the PT 

base element

5 V DC

PT 4- 5DC-ST

2839211

10

12 V DC

PT 4-12DC-ST

2839237

10

24 V DC

PT 4-24DC-ST

2839240

10

24 V AC

PT 4-24AC-ST

2800078

1

PLUGTRAB base element,

 for mounting on NS

 

35

Bridge between 3/4 (

) and 9/10

110 V AC

PT 4-BE

2839402

10

Gas-filled surge arrester between 3/4 (

) and 9/10

24 V AC

PT 4+F-BE

2839415

10

Accessories

Shield fast connection

For Ø 3-6 mm

SSA 3-6

2839295

10

For Ø 5-10 mm

SSA 5-10

2839512

10

121

PHOENIX CONTACT

– Consistently pluggable signal circuit 

protection

– Maximum ease of maintenance thanks to 

the two-piece design

– Base element remains an integral part of 

the installation

– Impedance-neutral disconnection of plug 

for test and maintenance purposes

– Plugs can be checked with 

CHECKMASTER

* Note:

Various grounding options for the base 
elements:

PT .x.-BE

 connections 9/10 (GND) 

directly connected to the mounting foot.

PT .x.+F-BE

 connections 9/10 (GND) 

connected to the mounting foot via a gas-
filled surge arrester.

Resistance-dependent measurements
PLUGTRAB PT

Surge protection and interference suppression filters

Surge protection for MCR technology

4-wire, floating, impedance-free, 

e.g., for temperature measurement

phoenixcontact-protection-html.html
background image

B

N

RD

B

U

B

K

WH

+

+

˜

˜

˜

˜

Ex: 

 

Technical data

Electrical data

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

36 V DC / 25 V AC

Pulse discharge current I

imp

 (10/350) µs

1 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

260 A / 10 kA

Maximum permitted short-circuit current at installation location

1 A (non-Ex)

Total discharge current I

total 

(8/20)

 

µs

20 kA

Max. discharge current I

max.

 (8/20) µs

-

Protection level U

p

Core-Core

 65 V (C3 - 10 A)

Core-Ground

 1.1 kV (C3 - 100 A)

Output voltage limitation at 1 kV/µs

Core-Core / Core-Ground

 60 V / -

General data

Dimensions W/H/D

28 mm

 

/

 

28 mm

 

/

 

79 mm

Temperature range

-40 °C ... 80 °C (non-Ex)

Test standards

EN

 

61643-21/A2 / EN 60079-0 / EN 60079-1 /

EN 60079-11 / EN 60079-26 / EN

 

60079-31

Safety data

EC-type examination certificate according to ATEX

KEMA 09ATEX0028 X

Identification according to ATEX

 II 1 G Ex ia IIC T4...T6

 II 2 G Ex d IIC T4...T6

Maximum internal capacitance C

i

1.65 nF

Maximum internal inductance L

i

1 µH

Maximum input current I

i

500 mA (T4 / 

 75 °C)

Maximum input voltage U

i

36 V DC

Maximum input power P

i

3 W

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

SURGETRAB

 protective adapter for installation on measuring 

sensors for Ex protection zones

Outer thread: M20 x 1.5

24 V DC

S-PT-4-EX-24DC

2800036

1

Outer thread: 1/2'' 14 NPT

24 V DC

S-PT-4-EX-24DC-1/2"

2800037

1

122

PHOENIX CONTACT

– Easy assembly, directly on the field device
– Arresters in hexagonal tube with various 

outer threads

S-PT-4-EX

 installation in a separate 

cable gland parallel to the signal cables

Resistance-dependent measurements
SURGETRAB

Surge protection and interference suppression filters

Surge protection for MCR technology

4-wire with common reference potential, 

intrinsically safe, encapsulated, without 

decoupling resistance

phoenixcontact-protection-html.html
background image

8

6
4

2

7

5
3

IN

OU

T

1

X

For further information and full technical data, visit phoenixcontact.net/products

 

 

Ex: 

 

 

Technical data

Electrical data

... 12DC

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

18 V DC / 13 V AC

36 V DC / 25 V AC

Rated current

500 mA (40°C)

500 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

500 A

500 A

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

350 A / 5 kA

250 A / 5 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

20 kA

Max. discharge current I

max.

 (8/20) µs

10 kA

10 kA

Protection level U

p

Core-Core / Core-Ground

 50 V (C3 - 10 A) / 

 650 V (C2 - 10 kV / 5 kA)

 60 V (C3 - 10 A) / 

 650 V (C2 - 10 kV / 5 kA)

Cut-off frequency fg (3 dB)

Symmetrical in the 50 

 system

typ. 5 MHz

typ. 7.7 MHz

Resistance per path

General data

Dimensions W/H/D

6.2 mm

 

/

 

93 mm

 

/

 

102.5 mm

Connection data solid/stranded/AWG

0.14...2.5

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 26 ... 12

Temperature range

-40 °C ... 80 °C

Test standards

EN

 

61643-21/A2 / EN 60079-0 / EN 60079-11 /

EN 60079-26 / IEC 60079-0 / IEC 60079-11

Safety data

EC-type examination certificate according to ATEX

KEMA 09ATEX0051 X

KEMA 09ATEX0051 X

Identification according to ATEX

 II 1 G Ex ia IIC T4...T6

 II 1 D Ex iaD 20 

T85°C...135°C

 II 1 G Ex ia IIC T4...T6

 II 1 D Ex iaD 20 

T85°C...135°C

Maximum internal capacitance C

i

6 nF

2.5 nF

Maximum internal inductance L

i

< 1 µH

< 1 µH

Maximum input current I

i

500 mA (T4 / -40...+80°C)

500 mA (T4 / -40...+80°C)

Maximum input voltage U

i

18 V DC

36 V DC

Maximum input power P

i

550 mW

550 mW

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

LINETRAB

12 V DC

LIT 4-12

2804704

10

24 V DC

LIT 4-24

2804678

10

Accessories

DIN rail connector

ME 6,2 TBUS-2 1,5/5-ST-3,81KMGY

2969401

10

123

PHOENIX CONTACT

– Protection of up to four signal wires with 

an overall width of 6.2 mm

– Can be used in binary, analog, and 

intrinsically safe circuits

Notes:

For approvals and dimensional drawing, visit 

phoenixcontact.net/products

For additional safety data, visit phoenixcontact.net/products

Resistance-dependent measurements
LINETRAB LIT

Surge protection and interference suppression filters

Surge protection for MCR technology

4-wire, floating, impedance-free, 

e.g., for temperature measurement

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

3

4

1

2

unprotected

protected

Technical data

Technical data

Electrical data

... 24DC

... 12DC

... 24DC

... 48DC

... 60DC

IEC test classification/EN type

C1 / C3

C1 / C3

C3

C3

C3

C3

C3

C3

Maximum continuous operating voltage U

C

30 V DC

15 V DC

 

30 V DC

 

53 V DC

 

75 V DC

 

Rated current

6 A (40°C)

10 A (60°C)

10 A (60°C)

10 A (60°C)

10 A (60°C)

10 A (60°C)

10 A (60°C)

10 A (60°C)

Protection level U

p

Core-Ground

 45 V (C3 - 

25 A)

 22 V (C3 - 

25 A)

 50 V (C3 - 

25 A)

 80 V (C3 - 

18 A)

 110 V (C3 - 

12 A)

Core-GND

-

-

-

-

-

Cut-off frequency fg (3 dB)

Asymmetrical in the 150 

 system

typ. 960 kHz

typ. 1.1 MHz

typ. 1.7 MHz

typ. 3.5 MHz

typ. 4 MHz

-

-

-

Resistance per path

100 m

100 m

100 m

100 m

100 m

General data

Dimensions W/H/D

6.2 mm

 

/

 

105.8 mm

 

/

 

69.5 mm

6.2 mm

 

/

 

92 mm

 

/

 

69.5 mm

6.2 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TERMITRAB complete,

 with Push-in connection technology

24 V DC

TTC-6-2XTVSD-24DC-PT

2906808

1

TERMITRAB complete, 

with screw connection technology

12 V DC

TTC-6-TVSD-C-12DC-UT-I

2906829

1

24 V DC

TTC-6-TVSD-C-24DC-UT-I

2906831

1

48 V DC

TTC-6-TVSD-C-48DC-UT-I

2906832

1

60 V DC

TTC-6-TVSD-C-60DC-UT-I

2906833

1

TERMITRAB complete,

 with Push-in connection technology

12 V DC

TTC-6-TVSD-C-12DC-PT-I

2906847

1

24 V DC

TTC-6-TVSD-C-24DC-PT-I

2906848

1

48 V DC

TTC-6-TVSD-C-48DC-PT-I

2906849

1

60 V DC

TTC-6-TVSD-C-60DC-PT-I

2906850

1

Accessories

Accessories

End cover

TTC-6-LCP

2908729

1

Remote signaling set

Screw connection technology

TTC-6-FMRS-UT

2907810

1

Push-in connection technology

TTC-6-FMRS-PT

2907811

1

124

PHOENIX CONTACT

– Fine surge protection for signal circuits on 

electronic controllers

– Overall width of just 6.2 mm
– With Push-in or screw connection 

technology

– Integrated mechanical status indicator
– Optional remote signaling module 

monitors up to 40 items, without 
additional wiring

Single-stage protective devices
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

2-conductor with common reference potential, 

e.g.,

 

for binary signals

1-conductor with grounded reference 

potential

H

W

D

new

H

W

D

new

phoenixcontact-protection-html.html
background image

3

4

1

2

unprotected

protected

For further information and full technical data, visit phoenixcontact.net/products

Technical data

... 24DC

... 48DC

... 60DC

IEC test classification/EN type

C1 / C3

C1 / C3

C3

C3

C3

C3

C3

C3

30 V DC

 

53 V DC

 

75 V DC

 

Rated current

6 A (40°C)

10 A (60°C)

10 A (60°C)

10 A (60°C)

10 A (60°C)

10 A (60°C)

10 A (60°C)

10 A (60°C)

-

-

-

 50 V (C3 - 

25 A)

 80 V (C3 - 

18 A)

 110 V (C3 - 

12 A)

 system

typ. 960 kHz

typ. 1.1 MHz

typ. 1.7 MHz

typ. 3.5 MHz

typ. 4 MHz

-

-

-

100 m

100 m

100 m

69.5 mm

6.2 mm

 

/

 

92 mm

 

/

 

69.5 mm

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Type

Order No.

Pcs./Pkt.

TTC-6-TVSD-D-24DC-UT-I

2906834

1

TTC-6-TVSD-D-48DC-UT-I

2906835

1

TTC-6-TVSD-D-60DC-UT-I

2906836

1

TTC-6-TVSD-D-24DC-PT-I

2906851

1

TTC-6-TVSD-D-48DC-PT-I

2906852

1

TTC-6-TVSD-D-60DC-PT-I

2906853

1

Accessories

TTC-6-LCP

2908729

1

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-PT

2907811

1

125

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

2-conductor, floating

H

W

D

new

phoenixcontact-protection-html.html
background image

3

4

1

2

unprotected

protected

3

4

1

2

unprotected

protected

Technical data

Technical data

Electrical data

... 24DC

... 48DC

... 60DC

... 120AC

... 24DC

IEC test classification/EN type

C1 / C2 / C3

C1 / C2 / C3

C1 / C2 / C3

C1 / C2 / C3

C1 / C2 / C3

Maximum continuous operating voltage U

C

30 V DC

60 V DC

75 V DC

 / 150 V AC

30 V DC

Rated current

10 A (60°C)

10 A (60°C)

10 A (60°C)

10 A (60°C)

10 A (60°C)

Nominal discharge current I

n

 (8/20) µs

Core-Ground / Core-GND

2 kA / -

2 kA / -

2 kA / -

2.5 kA / -

- / 2 kA

Protection level U

p

Core-Ground

 80 V (C3 - 

25 A)

 150 V (C3 - 

25 A)

 190 V (C3 - 

25 A)

 380 V (C3 - 

25 A)

-

Core-GND

-

-

-

-

 80 V (C3 - 25 A)

Cut-off frequency fg (3 dB)

Asymmetrical in the 150 

 system

typ. 200 kHz

typ. 650 kHz

typ. 650 kHz

typ. 1 MHz

-

Resistance per path

100 m

100 m

100 m

100 m

100 m

General data

Dimensions W/H/D

6.2 mm

 

/

 

92 mm

 

/

 

69.5 mm

6.2 mm

 

/

 

92 mm

 

/

 

69.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TERMITRAB complete, 

with screw connection technology

24 V DC

TTC-6-MOV-C-24DC-UT-I

2906837

1

TTC-6-MOV-D-24DC-UT-I

2906841

1

48 V DC

TTC-6-MOV-C-48DC-UT-I

2906838

1

60 V DC

TTC-6-MOV-C-60DC-UT-I

2906839

1

120 V AC

TTC-6-MOV-C-120AC-UT-I

2906840

1

TERMITRAB complete,

 with Push-in connection technology

24 V DC

TTC-6-MOV-C-24DC-PT-I

2906854

1

TTC-6-MOV-D-24DC-PT-I

2906859

1

48 V DC

TTC-6-MOV-C-48DC-PT-I

2906855

1

60 V DC

TTC-6-MOV-C-60DC-PT-I

2906857

1

120 V AC

TTC-6-MOV-C-120AC-PT-I

2906858

1

Accessories

Accessories

End cover

TTC-6-LCP

2908729

1

TTC-6-LCP

2908729

1

Remote signaling set

Screw connection technology

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-UT

2907810

1

Push-in connection technology

TTC-6-FMRS-PT

2907811

1

TTC-6-FMRS-PT

2907811

1

126

PHOENIX CONTACT

– Medium surge protection for signal 

circuits on electronic controllers

– Overall width of just 6.2 mm
– With Push-in or screw connection 

technology

– Integrated mechanical status indicator
– Optional remote signaling module 

monitors up to 40 items, without 
additional wiring

H

W

D

new

H

W

D

new

Single-stage protective devices
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

1-conductor with grounded reference 

potential

2-conductor, floating

phoenixcontact-protection-html.html
background image

3

4

1

2

unprotected

protected

3

4

1

2

unprotected

protected

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Electrical data

... 24AC

... 110AC

... 24AC

... 60AC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

- / 36 V AC

- / 130 V AC

- / 30 V AC

- / 75 V AC

Rated current

2 A (60°C)

2 A (60°C)

2 A (60°C)

2 A (60°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

0.5 kA

-

-

Nominal discharge current I

n

 (8/20) µs

Core-Ground / Core-GND

5 kA / -

5 kA / -

- / 5 kA

- / 5 kA

Protection level U

p

Core-Ground

 900 V (C3 - 100 A)

 900 V (C3 - 100 A)

-

-

Core-GND

-

-

 800 V (C3 - 25 A)

 800 V (C3 - 25 A)

Cut-off frequency fg (3 dB)

Asymmetrical in the 150 

 system

typ. 25 MHz

typ. 25 MHz

-

-

Resistance per path

100 m

100 m

100 m

100 m

General data

Dimensions W/H/D

6.2 mm

 

/

 

92 mm

 

/

 

69.5 mm

6.2 mm

 

/

 

92 mm

 

/

 

69.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TERMITRAB complete, 

with screw connection technology

24 V AC

TTC-6-GDT-C-24AC-UT-I

2906842

1

TTC-6-GDT-D-24AC-UT-I

2906845

1

60 V AC

TTC-6-GDT-D-60AC-UT-I

2906846

1

110 V AC

TTC-6-GDT-C-110AC-UT-I

2906844

1

TERMITRAB complete,

 with Push-in connection technology

24 V AC

TTC-6-GDT-C-24AC-PT-I

2906860

1

TTC-6-GDT-D-24AC-PT-I

2906862

1

60 V AC

TTC-6-GDT-D-60AC-PT-I

2906863

1

110 V AC

TTC-6-GDT-C-110AC-PT-I

2906861

1

Accessories

Accessories

End cover

TTC-6-LCP

2908729

1

TTC-6-LCP

2908729

1

Remote signaling set

Screw connection technology

TTC-6-FMRS-UT

2907810

1

TTC-6-FMRS-UT

2907810

1

Push-in connection technology

TTC-6-FMRS-PT

2907811

1

TTC-6-FMRS-PT

2907811

1

127

PHOENIX CONTACT

– Coarse surge protection, right at the 

building entrance, with an MCR cable

– Overall width of just 6.2 mm
– With Push-in or screw connection 

technology

– Integrated mechanical status indicator
– Optional remote signaling module 

monitors up to 40 items, without 
additional wiring

H

W

D

new

H

W

D

new

Single-stage protective devices
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

1-conductor with grounded reference 

potential

2-conductor, floating

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

4

5

6

1

2

3

unprotected

protected

Ex: 

 

Ex: 

 

Technical data

Technical data

Electrical data

... 24DC

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

30 V DC

30 V DC

Rated current

600 mA (40°C)

600 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

0.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

5 kA / 5 kA

5 kA / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

10 kA

Protection level U

p

Core-Core

 55 V (C3 - 100 A)

 55 V (C3 - 100 A)

Core-Ground

 1.4 kV (C3 - 100 A)

 1.4 kV (C3 - 100 A)

Cut-off frequency fg (3 dB)

Symmetrical in the 150 

 system

typ. 940 kHz

typ. 940 kHz

Resistance per path

1.65 

1.65 

General data

Dimensions W/H/D

6.2 mm

 

/

 

105.8 mm

 

/

 

83.5 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

EN 60079-0 / EN 60079-11 / EN 61643-21 /

EN 60079-0 / EN 60079-11 / EN 61643-21 /

IEC 60079-0 / IEC 60079-11 / IEC 61643-21

IEC 60079-0 / IEC 60079-11 / IEC 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TERMITRAB complete, 

with screw connection technology

24 V DC

TTC-6-1X2-M-EX-24DC-UT-I

2906820

1

TTC-6P-1X2-M-EX-24DC-UT-I

2906824

1

128

PHOENIX CONTACT

– One-piece or pluggable surge protection
– Tailored to the special requirements of 

intrinsically safe circuits

– Overall width of just 6.2 mm
– With screw connection technology
– Integrated mechanical status indicator
– With knife disconnection
– Impedance-neutral insertion and removal
– Coded connector versions
– Plugs can be tested with 

CHECKMASTER 2

new

new

Potentially explosive applications
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

Double wire (loop), floating, intrinsically safe, 

one-piece e.g.,

 

for 4

 

...

 

20

 

mA current loop

Double wire (loop), floating, intrinsically safe, 

pluggable, e.g.,

 

for 4

 

...

 

20

 

mA current loop

phoenixcontact-protection-html.html
background image

7

11

9

3

8

12

1

0

4

protected

unprotected

1

5

3

9

7

11

2

6

4

1

0

8

12

protected

unprotected

For further information and full technical data, visit phoenixcontact.net/products

Ex: 

 

 

Ex: 

 

 

Technical data

Technical data

Electrical data

... 24DC

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

30 V DC / 21 V AC

30 V DC / 21 V AC

Rated current

350 mA

350 mA

Pulse discharge current I

imp

 (10/350) µs

2 kA

2 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 10 kA

10 kA / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

20 kA

Protection level U

p

Core-Core

 50 V (C3 - 25 A)

 50 V (C3 - 25 A)

Core-Ground

 1.3 kV (C3 - 100 A)

 1.3 kV (C3 - 100 A)

Cut-off frequency fg (3 dB)

Symmetrical in the 150 

 system

typ. 1.1 MHz

typ. 1.1 MHz

Resistance per path

1.2 

1.2 

General data

Dimensions W/H/D

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 70 °C

-40 °C ... 70 °C

Test standards

EN

 

61643-21/A2 / IEC 61643-21/A2 / EN 61000-6-2 /

EN 61643-21 / IEC 61643-21 / EN 61000-6-2 /

EN 61000-6-3/A1

EN 61000-6-3/A1

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

MCR-PLUGTRAB,

 with screw connection technology

24 V DC

PT-IQ-1X2-EX-24DC-UT

2801512

1

PT-IQ-2X2-EX-24DC-UT

2801513

1

Accessories

Accessories

Replacement plug

24 V DC

PT-IQ-1X2-EX-24DC-P

2801514

1

PT-IQ-2X2-EX-24DC-P

2801515

1

PLUGTRAB, 

supply and remote signaling module

Screw connection technology

PT-IQ-PTB-UT

2800768

1

PT-IQ-PTB-UT

2800768

1

129

PHOENIX CONTACT

– Tailored to the special requirements of 

intrinsically safe circuits

– Multi-stage status monitoring
– Group message via supply and remote 

signaling module

– Multi-stage, floating remote signaling
– System supplied via DIN rail bus
– Up to 10 protection modules per supply 

module

– Maximum ease of maintenance thanks to 

the two-piece design

– Plugs  are  coded
– Impedance-neutral disconnection of plug 

for maintenance purposes

– Base element remains an integral part of 

the installation

– Corresponding replacement plugs can be 

found on our website

Potentially explosive applications
PLUGTRAB PT-IQ

Surge protection and interference suppression filters

Surge protection for MCR technology

Double wire (loop), floating, 

connection 9/10 grounded directly, 

e.g., for 4 ... 20

 

mA current loop  

2 double wires (loops), floating, 

connection 9/10 grounded directly, 

e.g., for 4 ... 20

 

mA current loop

phoenixcontact-protection-html.html
background image

IN

OU

T

B

K

B

N

1

B

L

2

B

N

B

U

/

B

K

+

˜

˜

Ex: 

 

 

Ex: 

 

Technical data

Technical data

Electrical data

... 24DC

... 24DC

... 48DC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

30 V DC / 21 V AC

36 V DC / 25 V AC

53 V DC / 37 V AC

36 V DC / 25 V AC

53 V DC / 37 V AC

Rated current

350 mA (50 °C)

-

-

-

-

Pulse discharge current I

imp

 (10/350) µs

1 kA

1 kA

1 kA

1 kA

1 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 10 kA

260 A / 10 kA

170 A / 10 kA

260 A / 10 kA

170 A / 10 kA

Maximum permitted short-circuit current at installation location

350 mA

1 A (non-Ex)

1 A (non-Ex)

1 A (non-Ex)

1 A (non-Ex)

Total discharge current I

total 

(8/20)

 

µs

-

20 kA

20 kA

20 kA

20 kA

Max. discharge current I

max.

 (8/20) µs

10 kA

-

-

-

-

Protection level U

p

Core-Core

 50 V (C3 - 25 A)

 65 V (C3 - 10 A)

 90 V (C3 - 10 A)

Core-Ground

 1.4 kV (C3 - 100 A)

 1.1 kV (C3 - 100 A)

 1.1 kV (C3 - 100 A)

Output voltage limitation at 1 kV/µs

Core-Core / Core-Ground

 50 V / 

 1.4 kV (Direct grounding)

 60 V / -

 80 V / -

Resistance per path

2.2 

-

-

-

-

General data

Dimensions W/H/D

34 mm

 

/

 

34 mm

 

/

 

137 mm

28 mm

 

/

 

28 mm

 

/

 

79 mm

28 mm

Temperature range

-40 °C ... 50 °C

-40 °C ... 80 °C (non-Ex)

-40 °C ... 80 °C (non-Ex)

Test standards

EN

 

61643-21/A2 / EN 60079-0 / EN 60079-11 /

EN

 

61643-21/A2 / EN 60079-0 / EN 60079-1 /

EN

EN 60079-26 / IEC 60079-0 / IEC 60079-11

EN 60079-11 / EN 60079-26 / EN

 

60079-31

EN 60079-11 / EN 60079-26 / EN

Safety data

EC-type examination certificate according to ATEX

KEMA 06ATEX0002

KEMA 09ATEX0028 X

KEMA 09ATEX0028 X

KEMA 09ATEX0028 X

KEMA 09ATEX0

Identification according to ATEX

 II 1G Ex ia IIC T4...T6 Ga

 II 1 G Ex ia IIC T4...T6

 II 2 G Ex d IIC T4...T6

 II 1 G Ex ia IIC T4...T6

 II 2 G Ex d IIC T4...T6

Maximum internal capacitance C

i

2 nF

1.65 nF

1.14 nF

1.65 nF

1.14 nF

Maximum internal inductance L

i

1 µH

1 µH

1 µH

1 µH

1 µH

Maximum input current I

i

350 mA (T4,T5,T6/

 50°C)

500 mA (T4 / 

 75 °C)

500 mA (T4 / 

 75 °C)

500 mA (T4 / 

Maximum input voltage U

i

30 V

36 V DC

53 V DC

36 V DC

53 V DC

Maximum input power P

i

3  W

3  W

3  W

3  W

3  W

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

SURGETRAB

 protective adapter for installation on measuring 

sensors for Ex protection zones

Outer thread: M20 x 1.5

24 V DC

S-PT-EX(I)-24DC

2880671

1

S-PT-EX-24DC

2800034

1

Outer thread: 1/2'' 14 NPT

24 V DC

S-PT-EX(I)-24DC-1/2"

2882572

1

S-PT-EX-24DC-1/2"

2800035

1

Outer thread:  3/4'' 14 NPT

24 V DC

S-PT-EX(I)-24DC-3/4"

2882585

1

Outer thread: M20 x 1.5

48 V DC

S-PT-EX-48DC

2800053

1

Outer thread: 1/2'' 14 NPT

48 V DC

S-PT-EX-48DC-1/2"

2800054

1

130

PHOENIX CONTACT

– Arresters in hexagonal tube with various 

outer threads

S-PT-EX(I)...

 installation in the signal 

path feed-through

S-PT-EX, S-PT-2xEX... 

installation in a 

separate cable gland parallel to the signal 
lines

Potentially explosive applications
SURGETRAB S-PT

Surge protection and interference suppression filters

Surge protection for MCR technology

Double wire (loop), intrinsically safe, 

e.g., for 4 ... 20

 

mA current loops  

Double wire (loop), floating, intrinsically safe, 

encapsulated, without decoupling resistance

phoenixcontact-protection-html.html
background image

B

N

RD

B

U

B

K

WH

For further information and full technical data, visit phoenixcontact.net/products

Ex: 

 

Technical data

... 24DC

... 48DC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

30 V DC / 21 V AC

36 V DC / 25 V AC

53 V DC / 37 V AC

36 V DC / 25 V AC

53 V DC / 37 V AC

Rated current

350 mA (50 °C)

-

-

-

-

 (10/350) µs

1 kA

1 kA

1 kA

1 kA

1 kA

Core-Core / Core-Ground

10 kA / 10 kA

260 A / 10 kA

170 A / 10 kA

260 A / 10 kA

170 A / 10 kA

Maximum permitted short-circuit current at installation location

350 mA

1 A (non-Ex)

1 A (non-Ex)

1 A (non-Ex)

1 A (non-Ex)

µs

-

20 kA

20 kA

20 kA

20 kA

 (8/20) µs

10 kA

-

-

-

-

 50 V (C3 - 10 A)

 80 V (C3 - 10 A)

 1.1 kV (C3 - 100 A)

 1.1 kV (C3 - 100 A)

 50 V / -

 80 V / -

-

-

-

-

79 mm

28 mm

 

/

 

28 mm

 

/

 

79 mm

-40 °C ... 80 °C (non-Ex)

-40 °C ... 80 °C (non-Ex)

61643-21/A2 / EN 60079-0 / EN 60079-1 /

EN

 

61643-21/A2 / EN 60079-0 / EN 60079-1 /

60079-31

EN 60079-11 / EN 60079-26 / EN

 

60079-31

EC-type examination certificate according to ATEX

KEMA 06ATEX0002

KEMA 09ATEX0028 X

KEMA 09ATEX0028 X

KEMA 09ATEX0028 X

KEMA 09ATEX0028 X

 II 1 G Ex ia IIC T4...T6

 II 2 G Ex d IIC T4...T6

 II 1 G Ex ia IIC T4...T6

 II 2 G Ex d IIC T4...T6

2 nF

1.65 nF

1.14 nF

1.65 nF

1.14 nF

1 µH

1 µH

1 µH

1 µH

1 µH

 75 °C)

500 mA (T4 / 

 75 °C)

500 mA (T4 / 

 75 °C)

30 V

36 V DC

53 V DC

36 V DC

53 V DC

3  W

3  W

3  W

3  W

3  W

Ordering data

Type

Order No.

Pcs./Pkt.

S-PT-2XEX-24DC

2800040

1

S-PT-2XEX-24DC-1/2"

2800041

1

S-PT-2XEX-48DC

2800038

1

S-PT-2XEX-48DC-1/2"

2800039

1

131

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for MCR technology

2 double wires (loops), floating, intrinsically 

safe, encapsulated, without decoupling 

resistance

phoenixcontact-protection-html.html
background image

IN

OU

T

4

3

1

0

9

2

1

12

11

6

5

8

7

 

 

Ex: 

 

 

 

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

30 V DC / 21 V AC

Rated current

325 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

2 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

Max. discharge current I

max.

 (8/20) µs

20 kA (in total)

Protection level U

p

Core-Core

 50 V (C3 - 25 A)

Core-Ground

 1 kV (C2 - 10 kV / 5 kA)

Output voltage limitation at 1 kV/µs

Core-Core / Core-Ground

 45 V / 

 1 kV

Cut-off frequency fg (3 dB)

Symmetrical in the 50 

 system

typ. 4.5 MHz

Resistance per path

2.2 

General data

Dimensions W/H/D

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

Test standards

EN 61643-21 / EN 60079-0 / EN 60079-11 /

EN 60079-26 / IEC 60079-0 / IEC 60079-11

Safety data

EC-type examination certificate according to ATEX

KEMA 00ATEX1099 X

Identification according to ATEX

 II 1G Ex ia IIC T4...T6 Ga

 II 1D Ex ia IIIC T135°C...T85°C Da

Maximum internal capacitance C

i

1.3 nF

Maximum internal inductance L

i

1 µH

Maximum input current I

i

325 mA (T4 / 

 80°C)

Maximum input voltage U

i

30 V DC

Maximum input power P

i

3 W

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

PLUGTRAB plug,

 with protective circuit for plugging into the PT 

base element

24 V DC

PT 2XEX(I)-24DC-ST

2838225

10

PLUGTRAB base element,

 for mounting on NS

 

35

24 V DC

PT 2XEX(I)-BE

2839279

10

Accessories

Shield fast connection

For Ø 3-6 mm

SSA 3-6

2839295

10

For Ø 5-10 mm

SSA 5-10

2839512

10

132

PHOENIX CONTACT

– Tailored to the special requirements of 

intrinsically safe circuits

– Consistently pluggable signal circuit 

protection

– Maximum ease of maintenance thanks to 

the two-piece design

– Base element remains an integral part of 

the installation

– Impedance-neutral disconnection of plug 

for test and maintenance purposes

– Plugs can be checked with 

CHECKMASTER

Potentially explosive applications
PLUGTRAB PT

Surge protection and interference suppression filters

Surge protection for MCR technology

2 double wires (loops), intrinsically safe, 

e.g., for 4 ... 20

 

mA current loops  

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

4

5

6

1

2

3

unprotected

protected

For further information and full technical data, visit phoenixcontact.net/products

Ex: 

 

Ex: 

 

Technical data

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

30 V DC

30 V DC

Rated current

600 mA (40°C)

600 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

0.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

- / 5 kA

- / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

10 kA

Protection level U

p

Core-Core

-

-

Core-Ground

 50 V (C3 - 100 A)

 50 V (C3 - 100 A)

Cut-off frequency fg (3 dB)

Symmetrical in the 150 

 system

-

-

Resistance per path

1.65 

1.65 

General data

Dimensions W/H/D

6.2 mm

 

/

 

105.8 mm

 

/

 

83.5 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

EN 60079-0 / EN 60079-11 / EN 61643-21 /

EN 60079-0 / EN 60079-11 / EN 61643-21 /

IEC 60079-0 / IEC 60079-11 / IEC 61643-21

IEC 60079-0 / IEC 60079-11 / IEC 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TERMITRAB complete, 

with screw connection technology

24 V DC

TTC-6-2X1-M-EX-24DC-UT-I

2906821

1

TTC-6P-2X1-M-EX-24DC-UT-I

2906825

1

133

PHOENIX CONTACT

– One-piece or pluggable surge protection
– Tailored to the special requirements of 

intrinsically safe circuits

– Overall width of just 6.2 mm
– With screw connection technology
– Integrated mechanical status indicator
– With knife disconnection
– Impedance-neutral insertion and removal
– Coded connector versions
– Plugs can be tested with 

CHECKMASTER 2

new

new

Potentially explosive applications
TERMITRAB complete

Surge protection and interference suppression filters

Surge protection for MCR technology

2-conductor with common reference potential, 

intrinsically safe, one-piece, 

e.g., for binary signals

2-conductor with common reference potential, 

intrinsically safe, pluggable, 

e.g., for binary signals

phoenixcontact-protection-html.html
background image

IN

OU

T

4

3

1

0

9

2

1

12

11

6

5

8

7

 

Ex: 

 

 

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

30 V DC / 21 V AC

Rated current

500 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

1 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

308 A / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

Max. discharge current I

max.

 (8/20) µs

20 kA (in total)

Protection level U

p

Core-Core

 50 V (C3 - 25 A)

Core-Ground

 1 kV (C2 - 10 kV / 5 kA)

Output voltage limitation at 1 kV/µs

Core-Core / Core-Ground

 45 V / 

 1 kV

Cut-off frequency fg (3 dB)

Symmetrical in the 50 

 system

typ. 7 MHz

Resistance per path

General data

Dimensions W/H/D

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

Test standards

EN 61643-21 / EN 60079-0 / EN 60079-11 /

EN 60079-26 / IEC 60079-0 / IEC 60079-11

Safety data

EC-type examination certificate according to ATEX

KEMA 00ATEX1099 X

Identification according to ATEX

 II 1G Ex ia IIC T4...T6 Ga

 II 1D Ex ia IIIC T135°C...T85°C Da

Maximum internal capacitance C

i

1.1 nF

Maximum internal inductance L

i

1 µH

Maximum input current I

i

500 mA (T4 / 

 80°C)

Maximum input voltage U

i

30 V DC

Maximum input power P

i

850 mW (T4 / 

 80°C)

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

PLUGTRAB plug,

 with protective circuit for plugging into the PT 

base element

24 V DC

PT 4-EX(I)-24DC-ST

2839253

10

PLUGTRAB base element,

 for mounting on NS

 

35

24 V DC

PT 4-EX(I)-BE

2839486

10

Accessories

Shield fast connection

For Ø 3-6 mm

SSA 3-6

2839295

10

For Ø 5-10 mm

SSA 5-10

2839512

10

134

PHOENIX CONTACT

– Tailored to the special requirements of 

intrinsically safe circuits

– Consistently pluggable signal circuit 

protection

– Maximum ease of maintenance thanks to 

the two-piece design

– Base element remains an integral part of 

the installation

– Impedance-neutral disconnection of plug 

for test and maintenance purposes

– Plugs can be checked with 

CHECKMASTER

Notes:

For approvals and dimensional drawing, visit 

phoenixcontact.net/products

Potentially explosive applications
PLUGTRAB PT

Surge protection and interference suppression filters

Surge protection for MCR technology

4-wire, intrinsically safe, impedance-free, 

e.g., for temperature measurements

phoenixcontact-protection-html.html
background image

B

N

RD

B

U

B

K

WH

+

+

˜

˜

˜

˜

For further information and full technical data, visit phoenixcontact.net/products

Ex: 

 

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

36 V DC / 25 V AC

Pulse discharge current I

imp

 (10/350) µs

1 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

260 A / 10 kA

Maximum permitted short-circuit current at installation location

1 A (non-Ex)

Total discharge current I

total 

(8/20)

 

µs

20 kA

Max. discharge current I

max.

 (8/20) µs

-

Protection level U

p

Core-Core

 65 V (C3 - 10 A)

Core-Ground

 1.1 kV (C3 - 100 A)

Output voltage limitation at 1 kV/µs

Core-Core / Core-Ground

 60 V / -

General data

Dimensions W/H/D

28 mm

 

/

 

28 mm

 

/

 

79 mm

Temperature range

-40 °C ... 80 °C (non-Ex)

Test standards

EN

 

61643-21/A2 / EN 60079-0 / EN 60079-1 /

EN 60079-11 / EN 60079-26 / EN

 

60079-31

Safety data

EC-type examination certificate according to ATEX

KEMA 09ATEX0028 X

Identification according to ATEX

 II 1 G Ex ia IIC T4...T6

 II 2 G Ex d IIC T4...T6

Maximum internal capacitance C

i

1.65 nF

Maximum internal inductance L

i

1 µH

Maximum input current I

i

500 mA (T4 / 

 75 °C)

Maximum input voltage U

i

36 V DC

Maximum input power P

i

3 W

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

SURGETRAB

 protective adapter for installation on measuring 

sensors for Ex protection zones

Outer thread: M20 x 1.5

24 V DC

S-PT-4-EX-24DC

2800036

1

Outer thread: 1/2'' 14 NPT

24 V DC

S-PT-4-EX-24DC-1/2"

2800037

1

135

PHOENIX CONTACT

– Arresters in hexagonal tube with various 

outer threads

S-PT-4-EX

 installation in a separate 

cable gland parallel to the signal cables

– S-PT-EX... devices are approved for Ex i 

and Ex d measuring probes

Potentially explosive applications
SURGETRAB S-PT

Surge protection and interference suppression filters

Surge protection for MCR technology

4-wire with common reference potential, 

intrinsically safe, encapsulated, without 

decoupling resistance

phoenixcontact-protection-html.html
background image

136

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

Low signal levels at high frequencies 

require special protective circuits in data 
processing and telecommunications. The 
arresters must guarantee short response 
times to quickly limit the surge voltages to 
safe values, without impairing signal quality. 
In addition, the protective devices support 
system-specific connections, such as RJ45 
or D-SUB connectors, and all types of 
network topology.

DATATRAB DT - the all-round 
solution for protecting data interfaces

DATATRAB DT reliably protects high-

speed networks against damage caused by 
surge voltages. DT-LAN-CAT.6+ supports 
various data protocols at very high 
transmission speeds, such as Ethernet, 
Power over Ethernet (PoE), ISDN, token 
ring, and DS1, in a single device.

The housing has a ground connection 

snap-on foot into which the ground 
connection cover with equipotential 
bonding cable is inserted. DATATRAB can 
be therefore used either as an adapter or a 
DIN rail module after removing the ground 
connection cover.

Your web code: 

#0145

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

137

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

Versatile

The DATATRAB product range can offer 

a suitable protective device for many and 
varied applications. The protective devices 
are simply installed between the signal paths 
with interfaces for RJ11/12, RJ45, D-SUB, or 
screw connection.

Speed

Used in EDP systems with a transmission 

speed of up to 10 Gbps (CAT6/CLASS E

a

and in telecommunications networks with 
50 Mbps (VDSL).

Use

Protective devices suitable for all 

common applications including Ethernet, 
token ring, ISDN, DS1, DSL, analog 
telecommunications, RS-485, V.24, V.11, 
etc. are available.

The circuit breakers also support Power 

over Ethernet (PoE) in Mode A and B 
versions.

The narrowest surge protection

Starting from a width of 3.5 mm, 

TERMITRAB complete is the world's 
narrowest surge protection solution for 
MCR and fieldbus applications.

COMTRAB modular

For protecting telecommunications 

systems
– Direct insertion in LSA-PLUS marshalling 

panels

– Coarse protection magazines with gas-

filled surge arrester

– Modular miniature connectors with 

combined coarse and fine protection 
elements for optimum protection

Other designs

Other application-specific protective 

devices include:
– Two-piece pluggable protective devices in 

the PLUGTRAB product range

– Combined adapters for the power supply 

and MAINTRAB interfaces

phoenixcontact-protection-html.html
background image

V

V

NT

V

V

V

V

Technology

Interface

Mounting / 
connection method

CAN bus / CANopen

®

DeviceNet™

Ethernet

GIGABIT ETHERNET (1/10 GBase-T)

D1/C2/C1

8

DT-LAN-CAT.6+

2881007

 142

FOUNDATION Fieldbus H1

D1/C2/C1

4

PT 2X2-FF-ST + PT 4-BE

2800755 + 2839402

 161

FOUNDATION Fieldbus EX (I)

INTERBUS INLINE (analog I/Os)

1

)

D1/C2/C1

4

PT-IQ-2X2-24DC-PT

2801263

 97

INTERBUS INLINE (digital I/Os)

1

)

D1/C2/C1

5

PT-IQ-4X1-24DC-PT

2801271

 111

INTERBUS remote bus

D1/C2/C1

LON (Works)

1

)

D1/C2/C1

2

PT-IQ-1X2-48DC-PT

2801257

 96

PROFIBUS DP (FMS)

1

)

D1/C2/C1

3

PROFIBUS PA (FMS)

D1/C2/C1

PROFINET

RS-422A, V.11, X.27, RS-423A

1

)

D1/C2/C1

5

PT-IQ-5-HF+F-12DC-PT

2801295

 147

RS-485

1

)

D1/C2/C1

RS-232-C/V.24

1

)

D1/C2/C1

3

TTC-6P-3-HF-F-M-12DC-PT-I

2906796

 151

TTY, 0(4) - 20 mA

1

)

D1/C2/C1

4

PT-IQ-2X2-24DC-PT

2801263

 97

ADSL 2+, T-DSL- HDSL, VDSL,

analog phone

1

)

D1/C2/C1

2

PT-IQ-1X2-TELE-PT

2801290

 163

LSA

D1/C2/C1

2

CTM 1X2-110AC + CTM 10-MAG

2838539 + 2838610

 166

 / 

D1/C2/C1 & T3

2

MNT-TEL... / MNT-TAE

2882404 / 2882394

 75

DSL broadband (coax)

ISDN (S

0

 & S

2M 

bus)

LSA

D1/C2/C1

2 x 2

CTM ISDN (2x) + CTM 10-MAG

2838555 + 2838610

 167

ISDN (U

k0

)

 / 

D1/C2/C1

4

DT-TELE-RJ45

2882925

 162

LSA

D1/C2/C1

2

CTM 1X2-110AC + CTM 10-MAG

2838539 + 2838610

 166

 / 

D1/C2/C1 & T3

2

MNT-TEL... / MNT-TAE

2882404 / 2882394

 75

SHDSL

 / 

D1/C2/C1

4

DT-TELE-SHDSL

2801593

 162

Note

Products bearing this stamp 

(plug elements) can be tested 

with the CHECKMASTER.

Selection guide

Explanation of the IEC categories

LPZ 
zone

Test category 
for SPD cor-
responds to
IEC 61643-21

Test class for 
SPD corre-
sponds to
IEC 61643-11

0/1

D1

I

1/2

C2

II

2/3

C1

III

DIN rail mounting

Push-in connection

Screw connection

Schuko plug-in connection

RJ45 plug-in connection

RJ12 plug-in connection

TAE plug-in connection

Coaxial plug-in connection

D-SUB plug-in connection

1

)

Also available with screw connection 

technology

138

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

IEC category

Protected 
wires

Surge protective device (SPD)

Order No.

Page

D1/C2/C1

3

PT-IQ-3-HF-12DC-UT

2800786

 153

T3

2

PLT-SEC-T3-24-FM

2905223

 71

D1/C2/C1

3

PT-IQ-3-HF-12DC-UT

2800786

 153

T3

2

PLT-SEC-T3-24-FM

2905223

 71

D1/C2/C1

8

DT-LAN-CAT.6+

2881007

 142

C2/C1

24 x 8

D-LAN-19"-24

2838791

 143

GIGABIT ETHERNET (1/10 GBase-T)

D1/C2/C1

8

DT-LAN-CAT.6+

2881007

 142

FOUNDATION Fieldbus H1

D1/C2/C1

4

PT 2X2-FF-ST + PT 4-BE

2800755

 + 

2839402

 161

D1/C2/C1

2

TTC-6P-1X2-M-EX-24DC-UT-I

2906824

 128

T3

2

PLT-SEC-T3-24-FM

2905223

 71

)

D1/C2/C1

4

PT-IQ-2X2-24DC-PT

2801263

 97

)

D1/C2/C1

5

PT-IQ-4X1-24DC-PT

2801271

 111

INTERBUS remote bus

D1/C2/C1

5

DT-UFB-IB-RBI

2800055

 159

5

DT-UFB-IB-RB0

2800056

 159

)

D1/C2/C1

2

PT-IQ-1X2-48DC-PT

2801257

 96

)

D1/C2/C1

3

TTC-6P-3-HF-M-12DC-PT-I

2906756

 151

PT-IQ-3-PB-PT

2801286

 146

C1

2

D-UFB-PB

2880642

 155

PROFIBUS PA (FMS)

D1/C2/C1

2

TTC-6P-3-HF-F-M-EX-24DC-UT-I

2906828

 157

4

PT 4-EX(I)-24DC-ST + PT 4-EX(I)-BE 

2839253

 + 

2839486

 134

D1/C2/C1

8

DT-LAN-CAT.6+

2881007

 142

)

D1/C2/C1

5

PT-IQ-5-HF+F-12DC-PT

2801295

 147

)

D1/C2/C1

3

TTC-6P-3-HF-F-M-12DC-PT-I

2906796

 151

5

PT-IQ-5-HF+F-12DC-PT

2801295

 147

D1/C2/C1

5

DT-UFB-485/BS

2920612

 147

C2/C1

9

DT-UFB-V24/S-9-SB

2803069

 144

)

D1/C2/C1

3

TTC-6P-3-HF-F-M-12DC-PT-I

2906796

 151

)

D1/C2/C1

4

PT-IQ-2X2-24DC-PT

2801263

 97

D1/C2/C1

4

DT-TELE-RJ45

2882925

 162

)

D1/C2/C1

2

PT-IQ-1X2-TELE-PT

2801290

 163

LSA

D1/C2/C1

2

CTM 1X2-110AC + CTM 10-MAG

2838539

 + 

2838610

 166

D1/C2/C1

4

TAE-TRAB FM-NFN-AP

2749628

 165

 / 

D1/C2/C1 & T3

2

MNT-TEL... / MNT-TAE

2882404

 / 

2882394

 75

D1/C2/C1

2

C-TV-SAT

2856993

 181

D1/C2/C1 & T3

2

MNT-TV-SAT D/WH

2882297

 75

LSA

D1/C2/C1

2 x 2

CTM ISDN (2x) + CTM 10-MAG

2838555

 + 

2838610

 167

D1/C2/C1

4

DT-LAN-CAT.6+

2881007

 142

 / 

D1/C2/C1

4

DT-TELE-RJ45

2882925

 162

D1/C2/C1

2

PT 2-TELE

2882828

 164

LSA

D1/C2/C1

2

CTM 1X2-110AC + CTM 10-MAG

2838539

 + 

2838610

 166

 / 

D1/C2/C1 & T3

2

MNT-TEL... / MNT-TAE

2882404

 / 

2882394

 75

SHDSL

 / 

D1/C2/C1

4

DT-TELE-SHDSL

2801593

 162

139

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

phoenixcontact-protection-html.html
background image

V

V

V

V

V

V

11

12

PLUGTRAB

PLT-SEC

T3-230-P

T3

Protection of PROFIBUS DP

PT-IQ-PTB-PT + PT-IQ-3-PB-PT

Optional

PT 5-HF-12DC-ST + PT 2X2-BE

2800768

 + 

2801286

2838775

 + 

2839208

Page 153

Page 147

Protection of PROFIBUS PA

PT 2XEX(I)-24DC + PT 2XEX(I)-BE

2838225

 + 

2839279

Page 132

Protection of CANopen

®

/DeviceNet™

PT 3-HF-12DC-ST + PT 1X2-BE

PLT-SEC-T3-24-FM

PT 3-HF-12DC-ST + PT 1X2-BE

2858043

 + 

2856113

2905223

2858043

 + 

2856113

Page 145

Page 71

Page 145

140

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

phoenixcontact-protection-html.html
background image

V

V

V

V

For further information and full technical data, visit phoenixcontact.net/products

Protection of an RS-485 interface

PT-IQ-PTB-PT + PT-IQ-5-HF+F-12DC-PT

Optional

PT 5-HF-12DC-ST + PT 2X2+F-BE

2801296

 + 

2801295

2838775

 + 

2839224

Page 147

Page 147

Protection of an Ethernet interface (including PoE)

– 100Base-T

– 1000Base-T

– 10GBase-T

DT-LAN-CAT.6+

2881007

Page 142

Protection of a DSL interface

– ADSL

– HDSL

– VDSL

PT 2-TELE

MNT-TAE D/WH

2882828

2882394

Page 164

Page 74

141

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

phoenixcontact-protection-html.html
background image

6

4

5

7

8

3

2

1

6

4

5

7

8

3

2

1

IN

OU

T

Technical data

Electrical data

IEC test classification/EN type

B2 / C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

 3.3 V DC

Rated current

 1.5 A (25 °C)

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

100 A / 2 kA (per signal pair)

350 A / 350 A

350 A / 350 A

Total discharge current I

total 

(8/20)

 

µs

10 kA

Protection level U

p

Core-Core / Core-Ground

 9 V (B2 - 1 kV/25 A) / 

 900 V (B2 - 4 kV/100 A)

Output voltage limitation at 1 kV/µs

Core-Core / Core-Ground

 9 V / 

 700 V

Input attenuation aE (typical)

 1 dB (up to100 MHz/direct measuring)

Cut-off frequency fg (3 dB)

In a 100 

 system

Symmetrical

> 500 MHz

General data

Dimensions W/H/D

25 mm

 

/

 

102 mm

 

/

 

63.5 mm

28 mm

Temperature range

-40 °C ... 70 °C

Connection method

RJ45

Test standards

IEC 61643-21 / EN 50173-1 / ISO/IEC 11801-Am.1

IEC 61643-21/A1 / GB/T 18802.21 / EN 61643-21/A1

IEC 61643-21

Ordering data

Description

Type

Order No.

Pcs./Pkt.

DATATRAB adapter,

 protective adapter to be inserted into the 

data line

DT-LAN-CAT.6+

2881007

1

DATATRAB,

 for use in Ethernet, token ring, FDDI/CDDI in acc. with 

Cat.D/CAT5 EN 50173 (1000Base-T)

24 ports

20 ports

16 ports

12 ports

8 ports

4 ports

Surge protection PCB 

 as replacement or for retrofitting in 

D-LAN-19"... products, incl. RJ45 sockets

4 ports

142

PHOENIX CONTACT

Ethernet/PROFINET networks with 
twisted pair cabling

DT-LAN-CAT.6+

– Suitable for category 6 high-speed data 

networks

– Secure data transmission up to 10 Gbps
– Protective adapter for eight signal paths 

via RJ45 connector

– Can be installed in a control cabinet by 

removing a ground connection adapter

D-LAN-CAT.5-FP

– Suitable for category 5 data networks
– Secure data transmission up to 1 Gbps
– Protective adapter for eight signal paths 

via RJ45 connector

D-LAN-19“

– 19" rack for installation in storey 

distributors

– Up to 24 ports with RJ45 connection
– Secure data transmission up to 1 Gbps
– Protection of all eight signal wires of the 

data cable

– Indirect grounding via a gas-filled surge 

arrester in the housing

– Direct grounding via a connection on the 

housing

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

For LAN interfaces (Class E

A

/CAT 6) including 

PoE and ISDN S

0

 protection

phoenixcontact-protection-html.html
background image

6

4

5

7

8

3

2

1

6

4

5

7

8

3

2

1

OU

T

IN

2

1

1

2

J2

J1

7

8

7

8

3 4 5 6

3 4 5 6

OU

T

IN

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

B2 / C1

C1 / C2 / C3 / B3

± 5 V DC

6 V DC

-

1.5 A (25 °C)

Core-Core / Core-Ground

100 A / 2 kA (per signal pair)

350 A / 350 A

350 A / 350 A

-

10  kA

 35 V (C1 - 700 V/350 A) / 

 700 V (C1 - 700 V/350 A)

 50 V (C1 - 500 V / 250 A) / 

 40 V (C1 - 500 V / 250 A (J2 ON))

 25 V / 

 750 V

 20 V / 

 30 V (J2 plugged)

 1 dB (100 MHz/100 

)

typ.  1  dB  (

 100 MHz)

> 100 MHz

> 100 MHz

63.5 mm

28 mm

 

/

 

110 mm

 

/

 

60 mm

483 mm

 

/

 

44 mm

 

/

 

160 mm

-40 °C ... 85 °C

-40 °C ... 80 °C

RJ45

RJ45

Test standards

IEC 61643-21 / EN 50173-1 / ISO/IEC 11801-Am.1

IEC 61643-21/A1 / GB/T 18802.21 / EN 61643-21/A1

IEC 61643-21

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

D-LAN-CAT.5-FP

2800723

1

D-LAN-19"-24

2838791

1

D-LAN-19"-20

2880134

1

D-LAN-19"-16

2880147

1

D-LAN-19"-12

2880150

1

D-LAN-19"-8

2880163

1

D-LAN-19"-4

2880176

1

D-LAN-19"-D-P

2880192

1

143

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

For LAN interfaces (Class D/CAT 5) including 

PoE and ISDN S

0

 protection

For data interfaces, with RJ45 connection

Class D/CAT5e

phoenixcontact-protection-html.html
background image

5

5

9

9

8

8

7

7

6

6

4

4

3

3

2

2

1

1

IN

OU

T

Total width 25 mm

Technical data

Electrical data

IEC test classification/EN type

B2 / C1 / C2 / C3

Maximum continuous operating voltage U

C

15 V DC / 10 V AC

Rated current

 1 A (25 °C)

Nominal discharge current I

n

 (8/20) µs

Core-Ground / Core-GND

 250 A / 

 250 A

Total discharge current I

total 

(8/20)

 

µs

5 kA

Protection level U

p

Core-Core / Core-Ground

 55 V (C1 - 250 A) / 

 450 V (C1 - 250 A)

Cut-off frequency fg (3 dB)

In a 100 

 system

Symmetrical / Asymmetrical

typ. 2.5 MHz / typ. 1.3 MHz

typ. 60 MHz / -

- / -

In a 150 

 system

Symmetrical / Asymmetrical

typ. 2.5 MHz / typ. 1.3 MHz

- / -

typ. 60 MHz / typ. 60 MHz

In a 100 

 system

Symmetrical / Asymmetrical

typ. 2.5 MHz / -

In a 150 

 system

Symmetrical / Asymmetrical

typ. 2.5 MHz / -

General data

Dimensions W/H/D

25 mm / 108 mm / 63 mm

17.7 mm / 90 mm / 65.5 mm

17.7 mm / 91.1 mm / 77.5 mm

Temperature range

-40 °C ... 85 °C

Connection method

D-SUB-9

Test standards

DIN EN 61643-21 / IEC 61643-21

EN 61643-21/A1 / IEC 61643-21/A1

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

Ordering data

Description

Type

Order No.

Pcs./Pkt.

DATATRAB adapter,

 protective adapter for inserting into the data 

line for protecting the V.24 / RS-232 interface with D-SUB-9 

connector

DT-UFB-V24/S-9-SB

2803069

1

PLUGTRAB plug,

 with protective circuit for plugging into the PT 

base element

PLUGTRAB base element,

 for mounting on NS

 

35

with a gas-filled surge arrester between the 3/4 (

) and the 9/10

connections

PLUGTRAB

, consisting of a plug, base element, and DIN rail bus

Screw connection technology

Push-in connection technology

Accessories

PLUGTRAB, 

supply and remote signaling module

Screw connection technology

Push-in connection technology

Marking material

144

PHOENIX CONTACT

V.24/RS-232 interfaces

DT-UFB-V24/S

– Connection:  D-SUB  9
– For data and handshake cables

Pin assignment DT-UFB-V24/S-9-SB

– 1,2,3,4,6,7,8,9 Data lines
– 5                   Signal ground (Ground)

PLUGTRAB PT 3-HF-12DC

– Connection: screw terminal blocks
– For high transmission speeds
– High discharge capacity
– Plugs can be checked with 

CHECKMASTER

Pin assignment PT 3-HF-12DC:

– 7,11 Data lines
– 9 Signal ground (Ground)
– 3      

* Note:PT .x.+F-BE

 connections 9/10 

(GND) are linked to the mounting foot via 
a gas-filled surge arrester.

PLUGTRAB PT-IQ 3-HF-12DC

– Connection: Push-in or screw connection 

technology

– For high transmission speeds
– High discharge capacity
– Multi-stage, floating remote signaling
– Group message via supply and remote 

signaling module

Pin assignment PT-IQ 3-HF-12DC

– 7,11 Data line pair 2 R(A)/R(B)
– 9 Signal ground (Ground)
– 3      

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

Protective adapter with 9-pos. D-SUB

Pluggable arrester with screw connection, 

phoenixcontact-protection-html.html
background image

*

IN

OU

T

7

11

9

3

8

12

1

0

4

7

11

9

3

8

12

1

0

4

protected

unprotected

For further information and full technical data, visit phoenixcontact.net/products

Total width 17.7 mm

Total width 17.7 mm

Technical data

Technical data

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

14 V DC / 9.8 V AC

15 V DC / 10 V AC

450 mA (45°C)

600 mA (40°C)

10 kA / 10 kA

10 kA / -

20 kA

20 kA

 50 V (C3 - 25 A) / 

 50 V (C3 - 25 A)

 40 V (C3 - 25 A) / 

 900 V (C3 - 25 A)

 system

Symmetrical / Asymmetrical

typ. 2.5 MHz / typ. 1.3 MHz

typ. 60 MHz / -

- / -

 system

Symmetrical / Asymmetrical

typ. 2.5 MHz / typ. 1.3 MHz

- / -

typ. 60 MHz / typ. 60 MHz

typ. 60 MHz / -

- / -

- / -

typ. 60 MHz / -

Dimensions W/H/D

25 mm / 108 mm / 63 mm

17.7 mm / 90 mm / 65.5 mm

17.7 mm / 91.1 mm / 77.5 mm

-40 °C ... 85 °C

-40 °C ... 70 °C

Screw connection (in connection with the base element)

Screw connection

Test standards

DIN EN 61643-21 / IEC 61643-21

EN 61643-21/A1 / IEC 61643-21/A1

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PT 3-HF-12DC-ST

2858043

10

PT 1X2+F-BE

2856126

10

PT-IQ-3-HF+F-12DC-UT

2800995

1

PT-IQ-3-HF+F-12DC-PT

2801289

1

Accessories

Accessories

PT-IQ-PTB-UT

2800768

1

PT-IQ-PTB-PT

2801296

1

ZBF ..., see page 197

145

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

H

W

D

Protective adapter with 9-pos. D-SUB

Pluggable arrester with screw connection, 

for three conductors, with common reference 

potential

3-wire protection for fieldbus and serial 

interface, connection 9/10 grounded via 

gas-filled surge arrester

phoenixcontact-protection-html.html
background image

protected

unprotected

7

11

5

1

9

3

2

6

8

12

1

0

4

Technical data

Electrical data

... 5DC

... 12DC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C

Maximum continuous operating voltage U

C

6 V DC

 

/

 

4 V AC

15 V DC

 

/

 

10 V AC

6 V DC

Rated current

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

450 mA (45°C)

450 mA (45°C)

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

10 kA

Protection level U

p

Core-Core / Core-Ground

 30 V (C3 - 25 A) / 

 30 V (C3 - 25 A)

 40 V (C3 - 25 A) / 

 40 V (C3 - 25 A)

Cut-off frequency fg (3 dB)

In a 100 

 system

Symmetrical

-

-

-

-

typ. 60 MHz

typ. 60 MHz

typ. 50 MHz

In a 150 

 system

Symmetrical

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

-

-

-

General data

Dimensions W/H/D

17.7 mm

 

/

 

91 mm

 

/

 

77.5 mm

17.7 mm

PT-IQ...UT dimensions W/H/D

17.7 mm

 

/

 

91 mm

 

/

 

77.5 mm

17.7 mm

PT-IQ...PT dimensions W/H/D

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

17.7 mm

Temperature range

-40 °C ... 70 °C

Connection method

Screw connection

Push-in connection

Screw connection

Push-in connection

Screw connection (in connection 

Test standards

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

EN 61643-21/A1 / IEC 61643-

Ordering data

Description

Nominal

voltage U

N

Type

Order No.

Pcs./Pkt.

MCR-PLUGTRAB,

 consisting of a plug, base element, and DIN rail 

bus, with screw connection technology

5 V DC

PT-IQ-5-HF-5DC-UT

2800797

1

12 V DC

PT-IQ-5-HF-12DC-UT

2800799

1

MCR-PLUGTRAB,

 consisting of a plug, base element, and DIN rail 

bus, with Push-in connection technology

5 V DC

PT-IQ-5-HF-5DC-PT

2801291

1

12 V DC

PT-IQ-5-HF-12DC-PT

2801293

1

PLUGTRAB plug,

 with protective circuit for plugging into the PT 

base element

PLUGTRAB base element,

 for mounting on NS

 

35

Bridge between 3/4 (

) and 9/10

Gas-filled surge arrester between 3/4 (

) and 9/10

DATATRAB adapter,

 protective adapter for inserting into the data 

line

Accessories

PLUGTRAB, 

supply and remote signaling module

Screw connection technology

PT-IQ-PTB-UT

2800768

1

Push-in connection technology

PT-IQ-PTB-PT

2801296

1

146

PHOENIX CONTACT

RS-485 interfaces

PLUGTRAB PT-IQ 5-HF

– Connection: Push-in or screw connection 

technology

– For high transmission speeds
– High discharge capacity
– Multi-stage, floating remote signaling
– Group message via supply and remote 

signaling module

Pin assignment PT-IQ-5-HF-12DC

– 1,5   Data line pair 1T(A)/T(B)
– 7,11 Data line pair 2 R(A)/R(B)
– 9      Signal ground (Ground)
– 3      

PLUGTRAB PT 5-HF

– High transmission speed
– Fast response time
– High discharge capacity
– Plugs can be checked with 

CHECKMASTER

Pin assignment PT 5-HF...:

– 1,5   Data line pair 1T(A)/T(B)
– 7,11 Data line pair 2 R(A)/R(B)
– 9      Signal ground (Ground)
– 3      

* Note:

Various grounding options for the base 
elements:

PT .x.-BE

 connections 9/10 (GND) 

directly connected to the mounting foot.

PT .x.+F-BE

 connections 9/10 (GND) 

connected to the mounting foot via a gas-
filled surge arrester.

DATATRAB DT-UFB-485

– Adapter type
– 9-pos. D-SUB connection
– DIN rail mounting possible by removing 

the cap

Pin assignment DT-UFB-485:

– 3,8 Data line pair 1 T(A)/T(B)
– 4,9 Data line pair 2 R(A)/R(B)
– 2,7 Signal ground (Ground)

    

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

Notes:

Attenuation characteristics at phoenixcontact.net/products

5-wire with common reference potential, 

9/10 connection grounded directly

phoenixcontact-protection-html.html
background image

protected

unprotected

7

11

5

1

9

3

2

6

8

12

1

0

4

*

IN

OU

T

2

6

8

7

12

11

5

1

1

0

9

4

3

IN

OU

T

4

3

4

3

9

8

2,

7

9

8

2,

7

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Technical data

... 5DC

... 12DC

... 5DC

... 12DC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

B2 / C1 / C2 / C3 / D1

10 V AC

6 V DC

 

/

 

4 V AC

15 V DC

 

/

 

10 V AC

5.2 V  DC

 

/

 

3.6 V AC

14 V DC

 

/

 

9.8 V AC

12 V DC

Rated current

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

450 mA (45°C)

450 mA (45°C)

 380 mA (25 °C)

Core-Core / Core-Ground

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

 5 kA / 

 5 kA

µs

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

10 kA

 30 V (C3 - 25 A) / 

 900 V (C3 - 25 A)

 40 V (C3 - 25 A) / 

 900 V (C3 - 25 A)

 45 V (C3 - 25 A) / 

 45 V (C3 - 25 A)

 50 V (C3 - 25 A) / 

 50 V (C3 - 25 A)

 30 V (C1 - 500 A) / 

 700 V (C1 - 500 A)

 system

Symmetrical

-

-

-

-

typ. 60 MHz

typ. 60 MHz

typ. 50 MHz

 system

Symmetrical

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

-

-

-

77.5 mm

17.7 mm

 

/

 

91 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

25 mm

 

/

 

108 mm

 

/

 

63 mm

77.5 mm

17.7 mm

 

/

 

91 mm

 

/

 

77.5 mm

-

-

77.5 mm

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

-

-

-40 °C ... 70 °C

-40 °C ... 85 °C

-40 °C ... 85 °C

Connection method

Screw connection

Push-in connection

Screw connection

Push-in connection

Screw connection (in connection 

with the base element)

Screw connection (in connection 

with the base element)

D-SUB-9

Test standards

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

EN 61643-21/A1 / IEC 61643-21/A1

DIN EN 61643-21

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PT-IQ-5-HF+F-5DC-UT

2800798

1

PT-IQ-5-HF+F-12DC-UT

2800801

1

PT-IQ-5-HF+F-5DC-PT

2801292

1

PT-IQ-5-HF+F-12DC-PT

2801295

1

PT 5-HF- 5 DC-ST

2838762

10

PT 5-HF-12 DC-ST

2838775

10

PT 2X2-BE

2839208

10

PT 2X2+F-BE

2839224

10

DT-UFB-485/BS

2920612

1

Accessories

Accessories

Accessories

PT-IQ-PTB-UT

2800768

1

PT-IQ-PTB-PT

2801296

1

147

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

H

W

D

H

W

D

5-wire with common reference potential, 

9/10 connection grounded via gas-filled surge 

arrester

Pluggable arrester with screw connection, 

for five conductors, with common reference 

potential

Protective adapter with 9-pos. D-SUB

phoenixcontact-protection-html.html
background image

*

IN

OU

T

2

6

8

7

12

11

5

1

1

0

9

4

3

protected

unprotected

7

11

5

1

9

3

2

6

8

12

1

0

4

Technical data

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

14 V DC / 9.8 V AC

15 V DC / 10 V AC

Rated current

450 mA (45°C)

600 mA (40°C)

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 20 kA (in total)

10 kA / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

20 kA

Protection level U

p

Core-Core / Core-Ground

 50 V (C3 - 25 A) / 

 50 V (C3 - 25 A)

 40 V (C3 - 25 A) / 

 900 V (C3 - 25 A)

Cut-off frequency fg (3 dB)

In a 100 

 system

Symmetrical

typ. 60 MHz

-

In a 150 

 system

Symmetrical / Asymmetrical

- / -

typ. 60 MHz / typ. 60 MHz

General data

Dimensions W/H/D

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

 

/

 

91 mm

 

/

 

77.5 mm

Temperature range

-40 °C ... 85 °C

-40 °C ... 70 °C

Test standards

EN 61643-21 / IEC 61643-21

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

Ordering data

Ordering data

Description

Nominal

voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PLUGTRAB plug

, with protective circuit for inserting in PT base 

element

12 V DC

PT 5-HF-12 DC-ST

2838775

10

PLUGTRAB base element,

 for mounting on NS

 

35

Gas-filled surge arrester between 3/4 (

) and 9/10

PT 2X2+F-BE

2839224

10

PLUGTRAB

, consisting of a plug, base element, and DIN rail bus

Screw connection technology

PT-IQ-5-HF+F-12DC-UT

2800801

1

PT-IQ-5-HF+F-12DC-PT

2801295

1

Accessories

Accessories

PLUGTRAB, 

supply and remote signaling module

Screw connection technology

PT-IQ-PTB-UT

2800768

1

Push-in connection technology

PT-IQ-PTB-PT

2801296

1

Marking material

ZBF ..., see page 197

148

PHOENIX CONTACT

PLUGTRAB PT 5-HF-12DC

– For high data transmission rates
– Plugs can be checked with 

CHECKMASTER

– 9/10 connections (GND) are connected 

to the mounting foot via a gas-filled surge 
arrester

PLUGTRAB PT-IQ-5-HF-12DC

– Connection: Push-in or screw connection 

technology

– For high transmission speeds
– Multi-stage, floating remote signaling
– Group message via supply and remote 

signaling module

Notes:

Attenuation characteristics at phoenixcontact.net/products

H

W

D

H

W

D

V.11/RS-422 interfaces

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

Pluggable arrester with screw connection, for 

five conductors, with common reference 

potential

5-wire with common reference potential, 

9/10 connection grounded via gas-filled surge 

arrester

phoenixcontact-protection-html.html
background image

*

IN

OU

T

4

3

1

0

9

2

1

12

11

6

5

8

7

1

5

3

9

7

11

2

6

4

1

0

8

12

protected

unprotected

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

28 V DC / 20 V AC

30 V DC / 21 V AC

Rated current

450 mA (45°C)

700 mA (50 °C)

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 10 kA

10 kA / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

20 kA

Protection level U

p

Core-Core / Core-Ground

 50 V (C3 - 25 A) / 

 450 V (C1 - 1

 

kV / 500

 

A with PT 2X2-BE)

 55 V (C3 - 25 A) / 

 700 V (C3 - 25 A)

Cut-off frequency fg (3 dB)

In a 50 

 system

Symmetrical

typ. 4.5 MHz

-

General data

Dimensions W/H/D

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

 

/

 

91 mm

 

/

 

77.5 mm

Temperature range

-40 °C ... 85 °C

-40 °C ... 70 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21 / EN 61000-6-3 /

Ordering data

Ordering data

Description

Nominal

voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PLUGTRAB plug

, with protective circuit for inserting in PT base 

element

24 V DC

PT 2X2-24DC-ST

2838228

10

PLUGTRAB base element,

 for mounting on NS

 

35

Bridge between 3/4 (

) and 9/10

PT 2X2-BE

2839208

10

PLUGTRAB

, consisting of a plug, base element, and DIN rail bus

Screw connection technology

PT-IQ-2X2-24DC-UT

2800980

1

Push-in connection technology

Accessories

Accessories

Shield fast connection

For Ø 3-6 mm

SSA 3-6

2839295

10

For Ø 5-10 mm

SSA 5-10

2839512

10

PLUGTRAB, 

supply and remote signaling module

Screw connection technology

PT-IQ-PTB-UT

2800768

1

Push-in connection technology

PT-IQ-PTB-PT

2801296

1

149

PHOENIX CONTACT

PLUGTRAB PT 2X2-24DC

– Plugs can be checked with 

CHECKMASTER

– 9/10 connections (GND) are directly 

connected to the mounting foot

PLUGTRAB PT-IQ-2X2-24DC

– Connection: Push-in or screw connection 

technology

– Multi-stage, floating remote signaling
– Group message via supply and remote 

signaling module

Notes:

Attenuation characteristics at phoenixcontact.net/products

H

W

D

TTY interfaces

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

Two double wires (loops), floating, 

for 20 mA current loops

2 double wires (loops), floating, 

connection 9/10 grounded directly, 

e.g., for 4 ... 20

 

mA current loop

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

Technical data

Electrical data

... 12DC

IEC test classification/EN type

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

15 V DC

Rated current

600 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

5 kA / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

Protection level U

p

Core-Core / Core-Ground

 25 V (C3 - 25 A) / 

 25 V (C3 - 25 A)

Cut-off frequency fg (3 dB)

Symmetrical in the 150 

 system

typ. 60 MHz

Resistance per path

1.65 

General data

Dimensions W/H/D

6.2 mm

 

/

 

105.8 mm

 

/

 

83.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

TERMITRAB complete, 

with screw connection technology

12 V DC

TTC-6-3-HF-M-12DC-UT-I

2906721

1

24 V DC

TERMITRAB complete,

 with Push-in connection technology

12 V DC

TTC-6-3-HF-M-12DC-PT-I

2906732

1

24 V DC

150

PHOENIX CONTACT

PROFIBUS DP/PA fieldbus system
TERMITRAB complete

– One-piece or pluggable surge protection
– Overall width of just 6.2 mm
– With Push-in or screw connection 

technology

– Integrated mechanical status indicator
– Impedance-neutral insertion and removal
– Coded connector versions
– With knife disconnection
– Optional remote signaling module 

monitors up to 40 items, without 
additional wiring

– Plugs can be tested with 

CHECKMASTER 2

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

new

3-conductor with common reference potential, 

3/6 connection grounded directly, one-piece

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

4

5

6

1

2

3

unprotected

protected

4

5

6

1

2

3

unprotected

protected

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Technical data

... 12DC

... 24DC

... 12DC

... 12DC

... 24DC

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

15 V DC

30 V DC

15 V DC

15 V DC

30 V DC

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

0.5 kA

0.5 kA

0.5 kA

0.5 kA

0.5 kA

5 kA / 5 kA

5 kA / 5 kA

5 kA / 5 kA

5 kA / 5 kA

5 kA / 5 kA

10 kA

10 kA

10 kA

10 kA

10 kA

 25 V (C3 - 25 A) / 

 1.1 kV (C3 - 25 A)

 45 V (C3 - 25 A) / 

 110 V (C3 - 25 A)

 25 V (C3 - 25 A) / 

 25 V (C3 - 25 A)

 25 V (C3 - 25 A) / 

 1.1 kV (C3 - 25 A)

 45 V (C3 - 25 A) / 

 110 V (C3 - 25 A)

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

1.65 

1.65 

1.65 

1.65 

1.65 

6.2 mm

 

/

 

105.8 mm

 

/

 

83.5 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-40 °C ... 85 °C

-40 °C ... 85 °C

-40 °C ... 85 °C

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TTC-6-3-HF-F-M-12DC-UT-I

2906769

1

TTC-6P-3-HF-M-12DC-UT-I

2906744

1

TTC-6P-3-HF-F-M-12DC-UT-I

2906786

1

TTC-6-3-HF-F-M-24DC-UT-I

2906770

1

TTC-6P-3-HF-F-M-24DC-UT-I

2906787

1

TTC-6-3-HF-F-M-12DC-PT-I

2906778

1

TTC-6P-3-HF-M-12DC-PT-I

2906756

1

TTC-6P-3-HF-F-M-12DC-PT-I

2906796

1

TTC-6-3-HF-F-M-24DC-PT-I

2906779

1

TTC-6P-3-HF-F-M-24DC-PT-I

2906797

1

151

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

new

H

W

D

new

H

W

D

new

3-conductor with common reference potential, 

3/6 connection grounded via gas-filled surge 

arrester, one-piece

3-conductor with common reference potential, 

3/6 connection grounded directly, pluggable

3-conductor with common reference potential, 

3/6 connection grounded via gas-filled surge 

arrester, pluggable

phoenixcontact-protection-html.html
background image

5

1

3

6

2

4

12

1

0

8

FM

FM

DC

 +

DC

Powe

r

S

P

D

DC

 +

DC

DC

FM

 

Technical data

Electrical data

IEC test classification/EN type

Maximum continuous operating voltage U

C

-

Rated current

-

Pulse discharge current I

imp

 (10/350) µs

-

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

- / -

Total discharge current I

total 

(8/20)

 

µs

-

Max. discharge current I

max.

 (8/20) µs

-

Protection level U

p

Core-Core

-

Core-Ground

-

Cut-off frequency fg (3 dB)

Symmetrical in the 150 

 system

-

Resistance per path

-

General data

PT-IQ...UT dimensions W/H/D

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

PT-IQ...PT dimensions W/H/D

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 70 °C

Test standards

EN 61000-6-2 / EN 61000-6-3 / EN 60950-1 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

IEC 61643-21 / EN 61643-21 /

EN 60079-0 / EN 60079-11 / EN 60079-15

Remote indication contact

2x N/C contacts

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 14

Max. operating voltage

30 V AC (50/60 Hz, non-Ex) / 50 V DC (non-Ex)

Max. operating current

1 A (up to 50°C, non-Ex)

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

PLUGTRAB, 

supply and remote signaling module

Screw connection technology

PT-IQ-PTB-UT

2800768

1

Push-in connection technology

PT-IQ-PTB-PT

2801296

1

MCR-PLUGTRAB,

 with screw connection technology

5 V DC

12 V DC

MCR-PLUGTRAB,

 with Push-in connection technology

5 V DC

12 V DC

152

PHOENIX CONTACT

PROFIBUS DP fieldbus system
PLUGTRAB PT-IQ

– Multi-stage status monitoring
– Group message via supply and remote 

signaling module

– Multi-stage, floating remote signaling
– System supplied via DIN rail bus
– Up to 28 protection modules per supply 

module

– Maximum ease of maintenance thanks to 

the two-piece design

– Plugs  are  coded
– Impedance-neutral disconnection of plug 

for maintenance purposes

– PT-IQ...-UT base element with screw 

connection technology

– PT-IQ...-PT base element with Push-in 

connection technology

– Base element remains an integral part of 

the installation

– Corresponding replacement plugs can be 

found on our website

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

Supply and remote signaling module

3-wire

phoenixcontact-protection-html.html
background image

7

11

9

3

8

12

1

0

4

protected

unprotected

protected

unprotected

7

11

5

1

9

3

2

6

8

12

1

0

4

For further information and full technical data, visit phoenixcontact.net/products

 

 

Technical data

Technical data

... 5DC

... 12DC

... 5DC

... 12DC

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

6 V DC / 4 V AC

15 V DC / 10 V AC

6 V DC / 4 V AC

15 V DC / 10 V AC

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

2.5 kA

2.5 kA

2.5 kA

2.5 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

20 kA

20 kA

20 kA

20 kA

-

-

-

-

 30 V (C3 - 25 A)

 40 V (C3 - 25 A)

 30 V (C3 - 25 A)

 40 V (C3 - 25 A)

 30 V (C3 - 25 A)

 40 V (C3 - 25 A)

 30 V (C3 - 25 A)

 40 V (C3 - 25 A)

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

1.2 

1.2 

1.2 

1.2 

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

91 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

109.3 mm

 

/

 

77.5 mm

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-40 °C ... 70 °C

-40 °C ... 70 °C

Test standards

EN 61000-6-2 / EN 61000-6-3 / EN 60950-1 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

EN 61000-6-3

EN 61000-6-3

Via TBUS

Via TBUS

-

 

mm²

 

/ -

 

mm²

 

/ -

-

 

mm²

 

/ -

 

mm²

 

/ -

-

-

-

-

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PT-IQ-3-PB-UT

2800785

1

PT-IQ-5-HF-5DC-UT

2800797

1

PT-IQ-3-HF-12DC-UT

2800786

1

PT-IQ-5-HF-12DC-UT

2800799

1

PT-IQ-3-PB-PT

2801286

1

PT-IQ-5-HF-5DC-PT

2801291

1

PT-IQ-3-HF-12DC-PT

2801288

1

PT-IQ-5-HF-12DC-PT

2801293

1

153

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

H

W

D

Supply and remote signaling module

3-wire protection for fieldbus and serial 

interface, connection 9/10 grounded directly

5-wire with common reference potential, 

9/10 connection grounded directly

phoenixcontact-protection-html.html
background image

*

IN

OU

T

7

11

9

3

8

12

1

0

4

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

5.2 V DC / 3.6 V AC

Rated current

450 mA (45°C)

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

Protection level U

p

Core-Core / Core-Ground

 45 V (C3 - 25 A) / 

 45 V (C3 - 25 A)

Output voltage limitation at 1 kV/µs

Core-Core / Core-Ground

 15 V / 

 15 V

Cut-off frequency fg (3 dB)

In a 100 

 system

Symmetrical

typ. 60 MHz

General data

Dimensions W/H/D

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

Temperature range

-40 °C ... 85 °C

Connection method

Screw connection (in connection with the base element)

Screw connection (in connection with the base element)

Sc

Test standards

EN 61643-21/A1 / IEC 61643-21/A1

EN 61643-21 / IEC 61643-21

IEC 61643-21

Ordering data

Description

Nominal

voltage U

N

Type

Order No.

Pcs./Pkt.

PLUGTRAB plug

, with protective circuit for inserting in 

PT base element

5 V DC

PT 3-PB-ST

2858030

10

12 V DC

PT 3-HF-12DC-ST

2858043

10

PLUGTRAB base element,

 for mounting on NS

 

35

Bridge between 3/4 (

) and 9/10

PT 1X2-BE

2856113

10

DATATRAB,

 protective device for PROFIBUS DP applications with 

up to 12 Mbps

Accessories

Shield fast connection

For Ø 3-6 mm

SSA 3-6

2839295

10

For Ø 5-10 mm

SSA 5-10

2839512

10

154

PHOENIX CONTACT

PROFIBUS DP fieldbus system
PLUGTRAB PT

PLUGTRAB PT 3-PB(HF)... / 
PT 5-HF...

– Protection for PROFIBUS (up to 

12 Mbps), in three to five-conductor 
technology

– Cable shield connection with SSA... shield 

fast connection

– Maximum ease of maintenance thanks to 

the two-piece design

– Base element remains an integral part of 

the installation

– Impedance-neutral disconnection of plug 

for test and maintenance purposes

DATATRAB D-UFB-PB

– Direct use at the PROFIBUS interface
– Data transmission rate of up to 12 Mbps
– Integrated termination resistor

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

Notes:

Attenuation characteristics at phoenixcontact.net/products

Pluggable arrester with screw connection, 

for three conductors, with common reference 

potential

phoenixcontact-protection-html.html
background image

*

IN

OU

T

2

6

8

7

12

11

5

1

1

0

9

4

3

3

8

5

6 V

G

N

D

D

(P)

D

(N)

P

IN

OU

T

2

B

2A

1

B

1A

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

C1 / C2 / C3 / D1

C1 / C3 / B2

14 V DC / 9.8 V AC

5.2 V DC / -

450 mA (45°C)

250 mA (25 °C)

10 kA / 20 kA (in total)

350 A / 350 A

20 kA

350 A

 50 V (C3 - 25 A) / 

 50 V (C3 - 25 A)

 25 V (C1 - 500 V / 250 A) / 

 25 V (C1 - 500 V / 250 A)

 25 V / 

 25 V (with PT 2X2-BE)

 14 V / 

 14 V

typ. 60 MHz

typ. 70 MHz

65.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

44.5 mm

 

/

 

58 mm

 

/

 

16.6 mm

-40 °C ... 85 °C

-20 °C ... 75 °C

element)

Screw connection (in connection with the base element)

Screw connection & D-SUB-9

Test standards

EN 61643-21/A1 / IEC 61643-21/A1

EN 61643-21 / IEC 61643-21

IEC 61643-21

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PT 5-HF-12 DC-ST

2838775

10

PT 2X2-BE

2839208

10

D-UFB-PB

2880642

1

Accessories

Accessories

SSA 3-6

2839295

10

SSA 5-10

2839512

10

155

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

Pluggable arrester with screw connection, 

for five conductors, with common reference 

potential

PROFIBUS fine protection with D-SUB 9

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

Ex: 

 

Technical data

Electrical data

... 12DC

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C

Maximum continuous operating voltage U

C

15 V DC

30 V DC

15 V DC

30 V DC

30 V DC / 21 V AC

30 V DC / 21 V AC

Rated current

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

350 mA

325 mA (40°C)

Pulse discharge current I

imp

 (10/350) µs

0.5 kA

0.5 kA

0.5 kA

0.5 kA

2 kA

2 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

5 kA / 5 kA

5 kA / 5 kA

5 kA / 5 kA

5 kA / 5 kA

10 kA / 10 kA

10 kA / 10 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

10 kA

10 kA

10 kA

20 kA

20 kA

Protection level U

p

Core-Core

 145 V (C1 - 1 kV/500 A)

 150 V (C1 - 1 kV/500 A)

Core-Ground

 750 V (C1 - 1 kV/500 A)

 750 V (C1 - 1 kV/500 A)

Core-GND

 80 V (C1 - 1 kV/500 A)

 80 V (C1 - 1 kV/500 A)

Cut-off frequency fg (3 dB)

Symmetrical in the 150 

 system

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

typ. 1.1 MHz

typ. 1.6 MHz

Resistance per path

1.65 

1.65 

General data

Dimensions W/H/D

6.2 mm

 

/

 

105.8 mm

 

/

 

83.5 mm

6.2 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

Temperature range

-40 °C ... 85 °C

Test standards

EN 60079-0 / EN 60079-11 / EN 61643-21 /

EN 60079-0 / EN 60079-11 / EN 61643-21 /

EN

IEC 60079-0 / IEC 60079-11 / IEC 61643-21

IEC 60079-0 / IEC 60079-11 / IEC 61643-21

EN 61000-6-3/A1

EN 60079-26 / IEC 60079-0 / IE

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

TERMITRAB complete, 

with screw connection technology

12 V DC

TTC-6-3-HF-F-M-EX-12DC-UT-I

2906822

1

24 V DC

TTC-6-3-HF-F-M-EX-24DC-UT-I

2906823

1

MCR-PLUGTRAB,

 with screw connection technology

24 V DC

PLUGTRAB plug,

 with protective circuit for plugging into the PT 

base element

24 V DC

PLUGTRAB base element,

 for mounting on NS

 

35

24 V DC

156

PHOENIX CONTACT

PROFIBUS PA fieldbus system

TERMITRAB complete

– One-piece or pluggable surge protection
– Tailored to the special requirements of 

intrinsically safe circuits

– Overall width of just 6.2 mm
– Integrated mechanical status indicator
– Impedance-neutral insertion and removal
– Coded connector versions
– With knife disconnection
– Plugs can be tested with 

CHECKMASTER 2

PLUGTRAB PT-IQ-EX

– Tailored to the special requirements of 

intrinsically safe circuits

– Multi-stage status monitoring
– Group message via supply and remote 

signaling module

– Multi-stage, floating remote signaling
– System supplied via DIN rail bus
– Up to 10 protection modules per supply 

module

– Maximum ease of maintenance thanks to 

the two-piece design

– Plugs  are  coded
– Impedance-neutral disconnection of plug 

for maintenance purposes

– Base element remains an integral part of 

the installation

– Corresponding replacement plugs can be 

found on our website

PLUGTRAB PT 2XEX(I)

– Tailored to the special requirements of 

intrinsically safe circuits

– Consistently pluggable signal circuit 

protection

– Maximum ease of maintenance thanks to 

the two-piece design

– Base element remains an integral part of 

the installation

– Impedance-neutral disconnection of plug 

for test and maintenance purposes

– Plugs can be checked with 

CHECKMASTER

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

new

3-conductor with common reference potential, 

intrinsically safe, one-piece

phoenixcontact-protection-html.html
background image

4

5

6

1

2

3

unprotected

protected

7

11

9

3

8

12

1

0

4

protected

unprotected

IN

OU

T

4

3

1

0

9

2

1

12

11

6

5

8

7

For further information and full technical data, visit phoenixcontact.net/products

Ex: 

 

Ex: 

 

 

 

 

Ex: 

 

 

 

Technical data

Technical data

Technical data

... 12DC

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

15 V DC

30 V DC

15 V DC

30 V DC

30 V DC / 21 V AC

30 V DC / 21 V AC

Rated current

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

600 mA (40°C)

350 mA

325 mA (40°C)

 (10/350) µs

0.5 kA

0.5 kA

0.5 kA

0.5 kA

2 kA

2 kA

Core-Core / Core-Ground

5 kA / 5 kA

5 kA / 5 kA

5 kA / 5 kA

5 kA / 5 kA

10 kA / 10 kA

10 kA / 10 kA

µs

10 kA

10 kA

10 kA

10 kA

20 kA

20 kA

 95 V (C1 - 1 kV/500 A)

 150 V (C1 - 1 kV/500 A)

 60 V (C1 - 1 kV/500 A)

 45 V (C1 - 0.5 kV / 250 A)

 1.1 kV (C1 - 1 kV/500 A)

 750 V (C1 - 1 kV/500 A)

 1.3 kV (C2 - 10 kV / 5 kA)

 1 kV (C1 - 1 kV/500 A)

 95 V (C1 - 1 kV/500 A)

 80 V (C1 - 1 kV/500 A)

-

-

 system

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

typ. 60 MHz

typ. 1.1 MHz

typ. 1.6 MHz

1.65 

1.65 

1.2 

2.2 

83.5 mm

6.2 mm

 

/

 

105.8 mm

 

/

 

100 mm

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-40 °C ... 85 °C

-40 °C ... 70 °C

-40 °C ... 85 °C

Test standards

EN 60079-0 / EN 60079-11 / EN 61643-21 /

EN 60079-0 / EN 60079-11 / EN 61643-21 /

EN

 

61643-21/A2 / IEC 61643-21/A2 / EN 61000-6-2 /

EN 61643-21 / EN 60079-0 / EN 60079-11 /

IEC 60079-0 / IEC 60079-11 / IEC 61643-21

IEC 60079-0 / IEC 60079-11 / IEC 61643-21

EN 61000-6-3/A1

EN 60079-26 / IEC 60079-0 / IEC 60079-11

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TTC-6P-3-HF-F-M-EX-12DC-UT-I

2906826

1

TTC-6P-3-HF-F-M-EX-24DC-UT-I

2906828

1

PT-IQ-1X2-EX-24DC-UT

2801512

1

PT 2XEX(I)-24DC-ST

2838225

10

PT 2XEX(I)-BE

2839279

10

157

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

new

H

W

D

3-conductor with common reference potential, 

intrinsically safe, pluggable

Double wire (loop), floating, 

connection 9/10 grounded directly, 

e.g., for 4 ... 20

 

mA current loop  

Double wire protection 

for two intrinsically safe circuits

phoenixcontact-protection-html.html
background image

protected

unprotected

7

11

5

1

9

3

2

6

8

12

1

0

4

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

6 V DC / 4 V AC

Rated current

600 mA (40°C)

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

Protection level U

p

Core-Core / Core-Ground

 30 V (C3 - 25 A) / 

 900 V (C3 - 25 A)

Cut-off frequency fg (3 dB)

In a 100 

 system

Symmetrical

-

In a 150 

 system

Symmetrical

typ. 60 MHz

General data

Dimensions W/H/D

17.7 mm

 

/

 

91 mm

 

/

 

77.5 mm

17.7 mm

Temperature range

-40 °C ... 70 °C

Connection method

Screw connection

Test standards

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

EN 61643-21/A1 / IEC 61643-21/A1

DIN EN 61643-21 / IEC 61643-21

DIN EN 6

Ordering data

Description

Nominal

voltage U

N

Type

Order No.

Pcs./Pkt.

MCR-PLUGTRAB,

 consisting of a plug, base element, and DIN rail 

bus, with screw connection technology

5 V DC

PT-IQ-5-HF+F-5DC-UT

2800798

1

PLUGTRAB plug,

 with protective circuit for plugging into the PT 

base element

PLUGTRAB base element,

 for mounting on NS

 

35

Gas-filled surge arrester between 3/4 (

) and 9/10

DATATRAB adapter,

 protective adapter for inserting into the data 

line

Accessories

PLUGTRAB, 

supply and remote signaling module

Screw connection technology

PT-IQ-PTB-UT

2800768

1

Push-in connection technology

PT-IQ-PTB-PT

2801296

1

158

PHOENIX CONTACT

INTERBUS remote bus

PLUGTRAB PT-IQ 5-HF

– Surge protection system
– Group message via supply and remote 

signaling module

– Multi-stage, floating remote signaling
– System supplied via DIN rail bus
– Base element with screw connection 

technology

PLUGTRAB PT 5-HF

– High transmission speed
– Fast response time
– High discharge capacity
– Plugs can be checked with 

CHECKMASTER

DATATRAB DT-UFB-IB-RBI/ -RBO

– Adapter type
– 9-pos. D-SUB connection
– For  remote  bus  modules
– DIN rail mounting possible by removing 

the cap

– D-SUB  cable  included

* Note:PT .x.+F-BE

 connections 9/10 

(GND) are linked to the mounting foot via 
a gas-filled surge arrester.

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

Notes:

For approvals and dimensional drawing, visit 

phoenixcontact.net/products

Pluggable arrester with screw connection, 

for five conductors, with common reference 

potential

phoenixcontact-protection-html.html
background image

*

IN

OU

T

2

6

8

7

12

11

5

1

1

0

9

4

3

IN

OU

T

6

7

6

7

1

2

3

1

2

3

I

I

I

I

IN

OU

T

6

7

6

7

1

2

3

1

2

3

I

I

I

I

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Technical data

C1 / C2 / C3 / D1

B2 / C1 / C2 / C3 / D1

B2 / C1 / C2 / C3 / D1

5.2 V DC / 3.6 V AC

5.8 V DC / -

5.8 V DC / -

450 mA (45°C)

 180 mA (25 °C)

 180 mA (25 °C)

10 kA / 10 kA

 5 kA / 

 5 kA

 5 kA / 

 5 kA

20 kA

10 kA

10 kA

 45 V (C3 - 25 A) / 

 45 V (C3 - 25 A)

 20 V (C1 - 500 A) / 

 700 V (C1 - 500 A)

 20 V (C1 - 500 A) / 

 700 V (C1 - 500 A)

typ. 60 MHz

 100 MHz

 100 MHz

-

 100 MHz

 100 MHz

77.5 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

25 mm

 

/

 

110 mm

 

/

 

63 mm

25 mm

 

/

 

110 mm

 

/

 

63 mm

-40 °C ... 85 °C

-40 °C ... 85 °C

-40 °C ... 85 °C

Screw connection (in connection with the base element)

D-SUB-9

D-SUB-9

Test standards

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

EN 61643-21/A1 / IEC 61643-21/A1

DIN EN 61643-21 / IEC 61643-21

DIN EN 61643-21 / IEC 61643-21

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PT 5-HF- 5 DC-ST

2838762

10

PT 2X2+F-BE

2839224

10

DT-UFB-IB-RB0

2800056

1

DT-UFB-IB-RBI

2800055

1

Accessories

Accessories

Accessories

159

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

H

W

D

H

W

D

Pluggable arrester with screw connection, 

for five conductors, with common reference 

potential

Protective adapter

for 5-wire remote bus input

Protective adapter 

for 5-wire remote bus output

phoenixcontact-protection-html.html
background image

*

IN

OU

T

2

6

8

7

12

11

5

1

1

0

9

4

3

Technical data

Electrical data

... 5DC

... 12DC

... 24DC

IEC test classification/EN type

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

Maximum continuous operating voltage U

C

5.2 V DC / 

3.6 V AC

14 V DC / 

9.8 V AC

28 V DC

5.2 V DC

Rated current

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

1.6 A

Pulse discharge current I

imp

 (10/350) µs

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

1 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 10 kA

10 kA / 20 kA 

(in total)

10 kA / 10 kA 

(with PT 2X2+F-BE)

Total discharge current I

total 

(8/20)

 

µs

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

-

Max. discharge current I

max.

 (8/20) µs

10 kA

20 kA (in total)

-

10 kA

10 kA

10 kA

10 kA

Output voltage limitation at 1 kV/µs

Core-Core

 15 V

 25 V

-

Core-Ground

 15 V

 25 V (with 

PT 2X2-BE)

-

-

-

-

-

Cut-off frequency fg (3 dB)

Symmetrical in the 100 

 system

typ. 60 MHz

typ. 60 MHz

typ. 70 MHz

typ. 70 MHz

typ. 70 MHz

typ. 70 MHz

-

Resistance per path

2.2 

2.2 

2.2 

General data

Dimensions W/H/D

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

17.7 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

0.2...4

Temperature range

-40 °C ... 85 °C

Test standards

EN 61643-21/A1 / IEC 61643-21/A1

IEC 61643-21

EN 61643-21/A1

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

PLUGTRAB plug

, with protective circuit for inserting in PT base 

element

5 V DC

PT 5-HF- 5 DC-ST

2838762

10

12 V DC

PT 5-HF-12 DC-ST

2838775

10

24 V DC

PT 5-HF-24DC-ST

2906002

1

32 V DC

PLUGTRAB base element,

 for mounting on NS

 

35

Bridge between 3/4 (

) and 9/10

PT 2X2-BE

2839208

10

Gas-filled surge arrester between 3/4 (

) and 9/10

PT 2X2+F-BE

2839224

10

Accessories

Shield fast connection

For Ø 3-6 mm

SSA 3-6

2839295

10

For Ø 5-10 mm

SSA 5-10

2839512

10

160

PHOENIX CONTACT

MCR-PLUGTRAB,
for various applications

– Protection for fieldbus systems and signal 

circuits with three to five-conductor 
technology

– Cable shield connection using SSA... 

shield fast connection

– Maximum ease of maintenance thanks to 

the two-piece design

– Base element remains an integral part of 

the installation

– Impedance-neutral disconnection of plug 

for test and maintenance purposes

* Note:

Various grounding options for the base 
elements:

PT .x.-BE

 connections 9/10 (GND) 

directly connected to the mounting foot.

PT .x.+F-BE

 connections 9/10 (GND) 

connected to the mounting foot via a gas-
filled surge arrester.

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

Notes:

Attenuation characteristics at phoenixcontact.net/products

5-wire protection 

for fieldbus and serial interface

phoenixcontact-protection-html.html
background image

*

IN

OU

T

2

6

8

7

12

11

5

1

1

0

9

4

3

*

IN

OU

T

4

3

1

0

9

2

1

12

11

6

5

8

7

For further information and full technical data, visit phoenixcontact.net/products

 

Ex: 

Ex: 

Technical data

Technical data

... 5DC

... 12DC

... 24DC

C1 / C2 / C3 / D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / 

D1

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

28 V DC

5.2 V DC

 

/

3.6 V AC

13 V DC

 

/

9 V AC

28 V DC

 

/

19.8 V AC

36 V DC

Rated current

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

450 mA (45°C)

1.6 A

 (10/350) µs

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

2.5 kA

1 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

100 A / 10 kA

µs

20 kA

20 kA

20 kA

20 kA

20 kA

20 kA

-

 (8/20) µs

10 kA

20 kA (in total)

-

10 kA

10 kA

10 kA

10 kA

 15 V

 25 V

 45 V

 75 V

-

-

-

-

-

 system

typ. 60 MHz

typ. 60 MHz

typ. 70 MHz

typ. 70 MHz

typ. 70 MHz

typ. 70 MHz

-

2.2 

2.2 

2.2 

65.5 mm

17.7 mm

 

/

 

45 mm

 

/

 

52 mm

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

/ 24 ... 12

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-

 

mm²

 

/ -

 

mm²

 

/ -

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

EN 61643-21/A1 / IEC 61643-21/A1

IEC 61643-21

EN 61643-21/A1

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

PT 2X2-HF- 5 DC-ST

2839567

10

PT 2X2-HF-12 DC-ST

2839570

10

PT 2X2-HF-24 DC-ST

2839729

10

PT 2X2-FF-ST

2800755

10

PT 2X2-BE

2839208

10

PT 4-BE

2839402

10

PT 2X2+F-BE

2839224

10

PT 4+F-BE

2839415

10

Accessories

Accessories

SSA 3-6

2839295

10

SSA 3-6

2839295

10

SSA 5-10

2839512

10

SSA 5-10

2839512

10

161

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

H

W

D

H

W

D

2 x 2-wire protection 

for 2-wire bus system

2 x 2-wire protection 

for FOUNDATION Fieldbus

phoenixcontact-protection-html.html
background image

IN

2

3

5

4

R

J 12

1

2

4

3

R

J 11

3

4

6

5

R

J 45

a

2

a

1

b2

b1

P

l

ug

OU

T

1

2

4

3

R

J 11

2

3

5

4

R

J 12

3

4

6

5

R

J 45

a

2

a

1

b2

b1

P

l

ug

unp

r

otected

2

3

5

4

R

J 12

1

2

4

3

R

J 11

3

4

6

5

R

J 45

Ba

A

a

B

b

Ab

P

l

ug

p

r

otected

1

2

4

3

R

J 11

2

3

5

4

R

J 12

3

4

6

5

R

J 45

Ba

A

a

B

b

Ab

P

l

ug

Technical data

Technical data

Electrical data

IEC test classification/EN type

B2 / C1 / C2 / C3 / D1

B2 / C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

185 V DC

185 V DC

Rated current

 380 mA (25 °C)

 380 mA (25 °C)

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

 5 kA / 

 5 kA

 5 kA / 

 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

10 kA

Protection level U

p

Core-Core / Core-Ground

 250 V (C1 - 1 kV/500 A) / 

 250 V (C1 - 1 kV/500 A)

 250 V (C1 - 500 A) / 

 580 V (C1 - 500 A)

Cut-off frequency fg (3 dB)

In a 100 

 system

Core-Core

typ. 50 MHz

25 MHz

General data

Dimensions W/H/D

25 mm / 102 mm / 63.5 mm

25 mm / 103 mm / 63 mm

Connection data solid/stranded/AWG

0.14...1.5

 

mm²

 

/ 0.14...1.5

 

mm²

 

/ 28 ... 16

0.14...1.5

 

mm²

 

/ 0.14...1.5

 

mm²

 

/ 28 ... 16

Temperature range

-40 °C ... 85 °C

-40 °C ... 85 °C

Connection method

RJ45/COMBICON

RJ45/COMBICON

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21

Ordering data

Ordering data

DATATRAB,

 protective adapter for insertion in the data cable

DT-TELE-RJ45

2882925

1

DT-TELE-SHDSL

2801593

1

162

PHOENIX CONTACT

DATATRAB DT

– Protection  for  two  DSL  ports
– Connection: RJ45 (RJ12/RJ11) and plug-in 

screw terminal block (COMBICON)

– Alternatively, can be snapped onto a DIN 

rail

– Protective  circuit:

Course/fine protection combination 
between all cables of signal wire pairs, as 
well as common mode voltage coarse 
protection between all signal wires and 
ground

– Separate ground connection line
– The adapter included enables conversion 

from RJ45 to RJ11 and RJ12 (for 
contacting, see circuit diagram)

H

W

D

H

W

D

DSL telecommunications

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

Attachment plug for two VDSL interfaces 

(ports)

Attachment plug for two SHDSL interfaces 

(ports)

phoenixcontact-protection-html.html
background image

7

11

9

3

8

12

1

0

4

protected

unprotected

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Electrical data

IEC test classification/EN type

C1 / C2 / C3 / D1 / B2

Maximum continuous operating voltage U

C

180 V DC

Rated current

150 mA (25 °C)

Pulse discharge current I

imp

 (10/350) µs

2.5 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 10 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

Protection level U

p

Core-Core

 290 V (C3 - 50 A)

Core-Ground

 700 V (C3 - 50 A)

Cut-off frequency fg (3 dB)

Symmetrical in the 150 

 system

typ. 25 MHz

Resistance per path

1.2 

General data

Dimensions W/H/D

17.7 mm

 

/

 

91.1 mm

 

/

 

77.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 70 °C

Test standards

IEC 61643-21 / EN 61643-21 / EN 61000-6-2 /

EN 61000-6-3

Remote indication contact

Via TBUS

Ordering data

Description

Type

Order No.

Pcs./Pkt.

DATA-PLUGTRAB

Screw connection technology

PT-IQ-1X2-TELE-UT

2800769

1

Push-in connection technology

PT-IQ-1X2-TELE-PT

2801290

1

Accessories

Replacement plug

PT-IQ-1X2-TELE-P

2800782

1

PLUGTRAB, 

supply and remote signaling module

Screw connection technology

PT-IQ-PTB-UT

2800768

1

Push-in connection technology

PT-IQ-PTB-PT

2801296

1

163

PHOENIX CONTACT

H

W

D

PLUGTRAB PT-IQ

– Multi-stage status monitoring
– Group message via supply and remote 

signaling module

– Multi-stage, floating remote signaling
– System supplied via DIN rail bus
– Up to 28 protection modules per supply 

module

– Maximum ease of maintenance thanks to 

the two-piece design

– Plugs  are  coded
– Impedance-neutral disconnection of plug 

for maintenance purposes

– PT-IQ...-UT base element with screw 

connection technology

– PT-IQ...-PT base element with Push-in 

connection technology

– Base element remains an integral part of 

the installation

– Corresponding replacement plugs can be 

found on our website

DSL telecommunications

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

Double wire (loop), floating, 

connection 9/10 grounded directly, 

e.g., for DSL applications

phoenixcontact-protection-html.html
background image

IN

OU

T

7

11

9

3

8

12

1

0

4

J

J

 

Technical data

Electrical data

IEC test classification/EN type

B2 / C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

185 V DC / 130 V AC

Rated current

450 mA AC (45°C)

Pulse discharge current I

imp

 (10/350) µs

1 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

10 kA / 10 kA

Total discharge current I

total 

(8/20)

 

µs

18 kA

Max. discharge current I

max.

 (8/20) µs

18 kA

Output voltage limitation at 1 kV/µs

Core-Core

 300 V

Core-Ground

 300 V

Cut-off frequency fg (3 dB)

Symmetrical in the 100 

 system

typ. 20 MHz

Resistance per path

2.2 

General data

Dimensions W/H/D

17.7 mm

 

/

 

90 mm

 

/

 

65.5 mm

Connection data solid/stranded/AWG

0.2...4

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

Temperature range

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

Ordering data

Description

Type

Order No.

Pcs./Pkt.

DATA-PLUGTRAB,

consisting of plug and base element

PT 2-TELE

2882828

10

Accessories

Replacement plug

PT 2-TELE-ST

2838733

10

Shield fast connection

For Ø 3-6 mm

SSA 3-6

2839295

10

For Ø 5-10 mm

SSA 5-10

2839512

10

164

PHOENIX CONTACT

Notes:

Attenuation characteristics at phoenixcontact.net/products

H

W

D

PT 2-TELE

– For analog telecommunications
– Two-piece, pluggable
– Universal use
– High discharge capacity
– Plugs can be checked with 

CHECKMASTER

DSL telecommunications

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

3-wire protection for DSL (ISDN U

k0

applications with common reference potential

phoenixcontact-protection-html.html
background image

L

b

L

a

4

5

6

3

2

1

4

5

6

3

2

1

4

5

6

3

2

1

N

F

N

a

2

b 2

E

W

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Electrical data

IEC test classification/EN type

B2 / C1 / C2 / C3 / D1

Nominal voltage U

N

60 V DC

Maximum continuous operating voltage U

C

185 V DC

Rated current

450 mA (

 40°C)

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

5 kA / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

Protection level U

p

Core-Core / Core-Ground

 250 V (C2 - 10 kV / 5 kA) / 

 500 V (C2 - 10 kV / 5 kA)

Output voltage limitation at 1 kV/µs

Core-Core / Core-Ground

 250 V / 

 450 V

Cut-off frequency fg (3 dB)

In a 600 

 system

Core-Core

typ. 2 MHz

General data

Dimensions W/H/D

65 mm / 27 mm / 80 mm

Temperature range

-40 °C ... 80 °C

Connection method

Screw connection & TAE 6

Test standards

DIN EN 61643-21 / IEC 61643-21

Ordering data

Description

For country-specific use

in

Type

Order No.

Pcs./Pkt.

TAE outlet box

 (NFN) with surge protection for analog 

telecommunications interfaces

Surface-mounted socket

D

TAE-TRAB FM-NFN-AP

2749628

1

165

PHOENIX CONTACT

– For  surface  mounting
– Three TAE6 slots
– For two N-coded and one F-coded 

terminal devices

– Suitable for ADSL and VDSL
– Main areas of application: Phone 

terminals, answering machines, modems, 
and fax machines

DSL telecommunications

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

TAE outlet box for VDSL (NFN)

phoenixcontact-protection-html.html
background image

IN

OU

T

1

2

2'

1'

IN

OUT

1

2

2'

1'

16.000

 

 

Technical data

Technical data

Electrical data

... 110AC

... 110AC

IEC test classification/EN type

B2 / C1 / C2 / C3 / D1

B2 / C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

60 V DC / 125 V AC

60 V DC / 125 V AC

Rated current

380 mA AC (25 °C)

380 mA AC (25 °C)

Pulse discharge current I

imp

 (10/350) µs

1 kA

1 kA

Nominal discharge current I

n

 (8/20) µs

Core-Core / Core-Ground

5 kA / 5 kA

- / 5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

10 kA

Protection level U

p

Core-Core

 260 V (C3 - 100 A)

-

Core-Ground

 800 V (C3 - 100 A)

 260 V (C3 - 100 A)

Cut-off frequency fg (3 dB)

Symmetrical/asymmetrical in the 100 

 system

typ. 20 MHz / -

- / typ. 20 MHz

Resistance per path

3.3 

3.3 

General data

Dimensions W/H/D

9.4 mm

 

/

 

21 mm

 

/

 

52.4 mm

9.4 mm

 

/

 

21 mm

 

/

 

52.4 mm

9.5 mm

Temperature range

-25 °C ... 75 °C

-25 °C ... 75 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

IEC 61643-21

IEC 61643-21

IEC 61643-21

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

COMTRAB modular

, surge protection for a double wire with 

coarse and fine protection and ohmic decoupling, DSL-compatible

110 V AC

CTM 1X2-110AC

2838539

10

CTM 2X1-110AC

2838526

10

180 V DC

COMTRAB modular

, surge protection for the ISDN S

0

 interface

6 V DC

Accessories

Accessories

Magazine

, with grounding rail for accommodating up to 10 LSA-

PLUS protective plugs (CTM...), for insertion in CT-TERMIBLOCK 

or LSA-PLUS disconnect strip

CTM 10-MAG

2838610

5

CTM 10-MAG

2838610

5

Grounding connector

CTM EST

2838649

10

CTM EST

2838649

10

166

PHOENIX CONTACT

– Space-saving LSA-PLUS connection 

technology

– Can be used in LSA-PLUS disconnect and 

control strips or CT-TERMIBLOCK

– The CTM 10-MAG surge protection 

magazine can be fitted with ten different 
protective plugs

For telecommunications and 
measurement and control interfaces
COMTRAB modular

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

Double wire (loop), floating

2-wire, with common reference potential

2-wire, with common reference potential

2-wire, coarse protec

phoenixcontact-protection-html.html
background image

IN

OU

T

1'

1

2'

2

IN

OU

T

1

2

2'

1'

J

J

IN

OU

T

1

2

2'

1'

J

J

J

J

For further information and full technical data, visit phoenixcontact.net/products

 

 

Technical data

Technical data

Technical data

B2 / C2 / C3 / D1 / C1

A2 / B1 / B2 / B3 / C1 / C2 / C3 / D1 / D2

A2 / B1 / B2 / B3 / C1 / C2 / C3 / D1 / D2

± 6 V DC

± 180 V DC

± 180 V DC

1.5 A (25 °C)

1.5 A (25 °C)

120 mA (25 °C)

1 kA

1 kA

1 kA

350 A / 5 kA

- / 5 kA

- / 5 kA

10 kA

10 kA

10 kA

 18 V (C3, 7.5 kV/100 A)

-

-

 700 V (C3 - 7.5 kV / 100 A, spike)

 1 kV (C3 - 7.5 kV / 100 A, spike)

 1 kV (C3 - 7.5 kV / 100 A, spike)

 100 MHz / -

- / > 100 MHz

- / > 100 MHz

-

-

5.5 

52.4 mm

9.5 mm

 

/

 

21 mm

 

/

 

53.5 mm

9.5 mm

 

/

 

21 mm

 

/

 

53.5 mm

9.5 mm

 

/

 

21 mm

 

/

 

53.5 mm

-25 °C ... 75 °C

-40 °C ... 85 °C

-40 °C ... 85 °C

Test standards

IEC 61643-21 / EN 61643-21

IEC 61643-21 / EN 61643-21

IEC 61643-21

IEC 61643-21

IEC 61643-21

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

CTM 2X1-180DC-GS

2838636

10

CTM 2X1-180DC-GS-P

2838623

10

CTM ISDN

2838555

10

Accessories

Accessories

Accessories

CTM 10-MAG

2838610

5

CTM 10-MAG

2838610

5

CTM 10-MAG

2838610

5

CTM EST

2838649

10

CTM EST

2838649

10

CTM EST

2838649

10

167

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

Double wire (loop), floating

2-wire, with common reference potential

2-wire, with common reference potential

2-wire, coarse protection, with failsafe contact

2-wire, coarse protection, with failsafe contact 

and current protection (Powercross)

phoenixcontact-protection-html.html
background image

b1

a

1

b2

a

2

b3

a

3

b4

a

4

b5

b

8/

b1

0

a

5

a8/a

1

0

b1

b2

b3

b4

b5

b

8/

b1

0

a

1

a

2

a

3

a

4

a

5

a8/a

1

0

Ordering data

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Coarse protection magazine,

 to accommodate 20 two-electrode 

gas-filled surge arresters, type H, unassembled, design: 10 double 

wires

CT 10-2/2-GS

2765398

5

Coarse protection magazine,

 for 10 double wires

unassembled,

 for accommodating 10 three-

electrode gas-filled surge arresters

CT 10-2/2-GS/3E

2765408

5

assembled,

 with 10 three-electrode gas-filled 

surge arresters

110 V AC

CT 10-2/2-GS/3E-110AC

2920829

10

Accessories

Accessories

2-electrode gas-filled surge arrester filled with inert gas,

type H, for use in CT 10-2/2-GS coarse protection magazine

48 V AC

SVP 2E- 48AC

2788919

10

110 V AC

SVP 2E-110AC

2765534

10

3-electrode gas-filled surge arrester filled with inert gas,

for use in CT 10-2/2-GS/3E coarse protection magazine

110 V AC

SVP 3E-110AC

2765521

10

168

PHOENIX CONTACT

– For use in CT-TERMIBLOCK or in 

LSA-PLUS and LSA-PROFIL disconnect 
and terminal strips

CT 10-2/2-GS

– For fitting with 20 two-electrode 

arresters filled with inert gas

– Common mode voltage coarse 

protection for 20 signal wires

CT ...-2/2-GS/3E

– Fitted with up to 10 three-electrode 

arresters filled with inert gas

– When the gas-filled surge arrester is 

triggered, the potentials of the three 
connections a-b-

 are equalized

– Coarse protection both in the normal 

mode voltage branch and the common 
mode voltage branch for 10 double wires

Notes:

For dimensional drawings, see phoenixcontact.net/products

LSA-PLUS coarse protection 
magazine

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

For 10 double wires (loops) 

and 20 two-electrode GDTs

For 10 double wires (loops) 

and 10 three-electrode GDTs

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

General data

Dimensions W/H/D

118 mm

 

/

 

43 mm

 

/

 

40.9 mm

112.5 mm

 

/

 

21.8 mm

 

/

 

44 mm

Connection data solid/stranded/AWG

0.2...2.5

 

mm²

 

/ 0.2...2.5

 

mm²

 

/ 24 ... 12

-

 

mm²

 

/ -

 

mm²

 

/ -

Temperature range

-40 °C ... 85 °C

-25 °C ... 75 °C

Degree of protection in acc. with IEC 60529/EN 60529

IP20

IP20

Inflammability class in acc. with UL 94

V2

V-0

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Screw terminal block,

 with disconnect contacts for 

accommodating the CT and CTM protective plugs, design: 

10 double wires

CT-TERMIBLOCK 10 DA

0441711

10

Magazine

, with grounding rail for accommodating up to 10 LSA-

PLUS protective plugs (CTM...), for insertion in CT-TERMIBLOCK 

or LSA-PLUS disconnect strip

CTM 10-MAG

2838610

5

H

W

D

– Screw terminal block
– For COMTRAB protective plugs
– Automatically closing feed-

through/disconnect contacts

– Ground terminal blocks on both sides 

with plug-in connection for the protective 
plugs used

– Mounting on DIN rails according to 

EN 60715

Notes:

For dimensional drawings, see phoenixcontact.net/products

CT-TERMIBLOCK

Surge protection and interference suppression filters

Surge protection for information technology and telecommunications

For accommodating the CT and CTM 

protective plugs, with screw connection

Magazine for 10 CTM

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

LSA-PLUS disconnect strip

 for accommodating the CTM and CT 

10 protection modules, design: 10 double wires

CT 10-TL

2765356

5

Grounding rail

 for CTM protective plug when used in combination 

with LSA-PLUS disconnect strip, design: 10 double wires

CT  1-10-ES

2765547

10

Mounting clip,

 for holding 3 disconnect or ground 

wire strips, design: 10 double wires

CT 10-MB/ 3

2765372

2

Mounting clip,

 for holding 10 disconnect or 

ground wire strips, design: 10 double wires

CT 10-MB/10

2765385

2

Cable feed-through sleeve

 for mounting trays, 

for protecting the lines guided through the 

laminated frame

CT-KDT

2765518

10

169

PHOENIX CONTACT

– LSA-PLUS disconnect strip
– For COMTRAB protective plugs
– For up to 10 CTM connectors

Notes:

For dimensional drawings, see phoenixcontact.net/products

COMTRAB disconnect strip

For accommodating the CT and CTM protective 

plugs, with LSA-PLUS connection

Grounding rail/mounting clip

phoenixcontact-protection-html.html
background image

170

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for transceiver systems

You won't lose reception with 
COAXTRAB

Transceiver systems are generally 

considered to be particularly susceptible to 
surge voltages. Antenna cables which 
extend beyond a building and are usually 
very long, plus the antennas themselves, are 
directly exposed to atmospherical 
discharge.

Cables with a coaxial structure and 

therefore favorable EMC properties are 
primarily used in antenna systems. However, 
the risk of surge voltage coupling in antenna 
cables and potential transfer through to the 
sensitive interfaces of transceiver systems is 
not eliminated.

Thanks to interface-optimized surge 

protective devices, the COAXTRAB 
product range significantly increases safety 
for transceiver equipment. The aim of such 
safety measures is to increase the availability 
and operability of the devices affected.

Your web code: 

#0146

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

171

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for transceiver systems

Shielding

Good shielding properties are vital for 

clean transmission. The robust metal 
housings provide ideal shielding properties 
and are also suitable for use in harsh 
industrial environments.

Customized products

Appropriate protective devices are 

available for all applications including SAT 
receiver systems, mobile phones, and video 
monitoring.

The very low attenuation values ensure 

that data transmission is clean.

Performance classes

The protective devices conform to 

standards in all performance classes. This 
applies for coarse protection in accordance 
with Category D1, 10/350 μs, and for fine 
protection in accordance with Category C2 
and C1, 8/20 μs.

Connection technology

The right connection technology to suit 

the application: F connector, TV connector, 
type N, 7/16, BNC, SMA.

phoenixcontact-protection-html.html
background image

Powe

r

Technology

Interface

Connection 
technology

GPS, GSM, UMTS, LTE

(900, 1800, 1900 MHz)

Type N

GSM, UMTS, LTE (without COAX DC 

supply) (900, 1800, 1900 MHz)

Type N

D1/C2/C3

2

CN-LAMBDA/4-2.25

2801057 / 2801056

 178

WiMAX, LTE (2.4 to 6 GHz)

Type N

D1/C2/C3

2

CN-LAMBDA/4-5.9

2838490 / 2800023

 178

GSM, Industrial Wireless (2.4 GHz)

Type SMA

D1/C2/C3

2

CSMA-LAMBDA/4-2.0-BS-SET

2800491

 178

Satellite television 

(upstream of the antenna distributor)

Type F

D1/C2/C1

5 x 2

C-SAT-BOX

2880561

 180

Satellite television 

(upstream of the SAT receiver or TV)

Type F

D1/C2/C1

2

C-TV-SAT

2856993

 180

 

Type F + IEC

D1/C2/C3 & T3

2

MNT-TV-SAT

2882297

 74

Cable/terrestrial TV

Type IEC

D1/C2/C1

2

C-TV/HIFI

2857002

 180

 

Type F + IEC

D1/C2/C3 & T3

2

MNT-TV-SAT

2882297

 74

Video monitoring (coax connection)

Type BNC

Video monitoring (2-wire connection)

D1/C2/C1

2

PT-IQ-3-PB+F-UT

The interface matrix indicates which 

surge protective device is suitable for a 
specific interface.

Note:

For further interface recommendations, 

visit phoenixcontact.net/products.

1

The PT-IQ-PTB-UT supply module is 

required in order to operate the PT-IQ 
series.

Explanation of the IEC categories

LPZ 
zone

Test category 
for SPD cor-
responds to
IEC 61643-21

Test class for 
SPD corre-
sponds to
IEC 61643-11

0/1

D1

I

1/2

C2

II

2/3

C1

III

Screw connection

Schuko plug-in connection

Coaxial plug-in connection

172

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for transceiver systems

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

IEC category

Protected 
wires

Surge protective device (SPD)

Order No.

Page

D1/C2/C3

2

CN-UB-280DC-3

2801050

 / 

2801051

 176

D1/C2/C3

2

CN-UB-70-6

2803166

 / 

2803153

 176

Type N

D1/C2/C3

2

CN-LAMBDA/4-2.25

2801057

 / 

2801056

 178

WiMAX, LTE (2.4 to 6 GHz)

Type N

D1/C2/C3

2

CN-LAMBDA/4-5.9

2838490

 / 

2800023

 178

GSM, Industrial Wireless (2.4 GHz)

Type SMA

D1/C2/C3

2

CSMA-LAMBDA/4-2.0-BS-SET

2800491

 178

Type F

D1/C2/C1

5 x 2

C-SAT-BOX

2880561

 180

Type F

D1/C2/C1

2

C-TV-SAT

2856993

 180

 

Type F + IEC

D1/C2/C3 & T3

2

MNT-TV-SAT

2882297

 74

Type IEC

D1/C2/C1

2

C-TV/HIFI

2857002

 180

 

Type F + IEC

D1/C2/C3 & T3

2

MNT-TV-SAT

2882297

 74

D1/C2/C3

2

C-UFB-5DC/E

2782300

 176

D1/C2/C3

2

C-UFB-5DC/E 75

2763604

 176

Video monitoring (2-wire connection)

D1/C2/C1

2

PT-IQ-3-PB+F-UT

1

)

2800994

 96

173

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for transceiver systems

phoenixcontact-protection-html.html
background image

V

V

V

V

V

V

IN

OUT

V

V

V

V

V

V

1

2

3

IN

4

5

1

2

3

OUT

4

5

C-S

AT-BOX

28 80 561

Überspannungsschut

z

Sur

ge v

oltage protection

U

c

= 20 V

DC

I n

= 2,5 kA

f

= 47 - 2200 MHz

0123-156789

D-105

V

V

V

V

V

V

Protection of video signals

C-UFB 5DC

PT 3-HF-12DC-ST + PT 1X2-BE

2797858

2858043

 + 

2856113

Page 177

Page 144

Protection of the SAT antenna connection

C-SAT-BOX

2880561

Page 180

Protection of the cable TV connection

MNT-TV-SAT D

2882284

Page 75

174

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for transceiver systems

phoenixcontact-protection-html.html
background image

V

V

V

V

V

V

For further information and full technical data, visit phoenixcontact.net/products

Protection of antenna signals

– GPS

– GSM

– UMTS

CN-UB-280DC-3-BB

Optional

CN-LAMBDA/4-2.25-BB

2801050

2801057

Page 176

Page 178

175

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for transceiver systems

phoenixcontact-protection-html.html
background image

6

6

Technical data

Technical data

Electrical data

IEC test classification/EN type

C2 / C3 / D1

C2 / C3 / D1

Maximum continuous operating voltage U

C

280 V DC

70 V DC / 50 V AC

Rated current

5 A (25 °C)

10 A

Nominal discharge current I

n

 (8/20) µs

Core-Shield / Core-Ground

20 kA / 20 kA

5 kA / 5 kA

Total discharge current I

total 

(8/20)

 

µs

20 kA

5 kA

Protection level U

p

Core-Shield / Core-Ground

 900 V (C1 - 1 kV/500 A) / 

 900 V (C1 - 1 kV/500 A)

 800 V (C2 - 4 kV/2 kA) / 

 800 V (C2 - 4 kV/2 kA)

In a 50 

 system

Asymmetrical

> 3 GHz

> 6 GHz

Standing wave ratio SWR in a 50 

 system

typ. 1.15 (

 3 GHz)

typ. 1.15 (

 6 GHz)

Permissible RF power P

max

700 W (VSWR = 1.1)

30 W (VSWR = 1.15)

General data

Dimensions W/H/D

31 mm / - / 33.5 mm

24 mm / 50 mm / 24 mm

25.4 mm / 96 mm / 25.4 mm

25.4 mm / 80 mm / 25.4 mm

25.4 mm / - / 93 mm

Temperature range

-40 °C ... 80 °C

-40 °C ... 90 °C

Degree of protection in acc. with IEC 60529/EN 60529

IP55

IP68

Connection method

N connector 50  

N connector 50  

Test standards

IEC 61643-21/A1 / -

IEC 61643-21

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

COAXTRAB,

 protective adapter for antenna connections

Socket-socket

CN-UB-280DC-3-BB

2801050

1

CN-UB-70DC-6-BB

2803166

1

Connector-socket

CN-UB-280DC-3-SB

2801051

1

CN-UB-70DC-6-SB

2803153

1

COAXTRAB,

 as surge protection for coaxial cables, connection via 

connector and socket

BNC 50 

BNC 75 

BNC 50 

Accessories

Accessories

Mounting plate

, for individual attachment to housing panels

straight

CN-UB/MP

2818135

10

CN-UB/MP

2818135

10

angled

CN-UB/MP-90DEG-50

2803137

10

CN-UB/MP-90DEG-50

2803137

10

BNC connector

, single-level, for mounting on NS

 

32 or NS

 

35/7.5

50 

 wave impedance

75 

 wave impedance

Adapter,

 insertion loss <0.3 dB at 2.4 GHz

N (male) -> SMA (female)

RAD-ADP-N/M-SMA/F

2917036

1

Adapter cable,

 pigtail, 50 

 impedance;

50 cm long, MCX (male) -> N (male)

RAD-PIG-EF316-MCX-N

2867681

1

176

PHOENIX CONTACT

– For antennas with N and BNC 

connection

– High transmission capacities even for 

frequencies up to 6 GHz

– Mounting plate enables fixed mounting, 

e.g., in a control cabinet

– The protective adapters can also be used 

in a 75 Ω system with 50 Ω BNC 
connectors

– For the CN-UB-280DC, the gas-filled 

surge arrester can be replaced in case of 
malfunction

Notes:

Attenuation characteristics at phoenixcontact.net/products

Antenna systems

Surge protection and interference suppression filters

Surge protection for transceiver systems

For GSM systems (0-3 GHz), grounded shield, 

connection: type N

For GSM systems (0 - 6 GHz), grounded shield, 

connection: type N

phoenixcontact-protection-html.html
background image

IN

OU

T

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Technical data

... 5DC/E

... 24DC/E

... 5DC/E 75

C2 / C3 / D1

C2 / C3 / D1

C2 / C3 / D1

C2 / C3 / D1

C2 / C3 / D1

180 V DC / 130 V AC

180 V DC / 130 V AC

5 V DC

30 V DC

-

5 A (25 °C)

3.5 A (25 °C)

185 mA (25 °C)

185 mA (25 °C)

185 mA (25 °C)

5 kA / 5 kA

5 kA / 5 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA / 10 kA

10 kA

10 kA

20 kA

20 kA

20 kA

 700 V (C2 - 10 kV / 5 kA) /

 500 V (C2 - 10 kV / 5 kA)

 700 V (C2 - 10 kV / 5 kA) / 

 500 V (C2 - 10 kV / 5 kA)

 25 V (C3 - 

10 A) / 

 500 V 

(C3 - 10 A)

 50 V (C3 - 

10 A) / 

 500 V 

(C3 - 10 A)

 25 V (C3 - 10 A) / 

 500 V (C3 - 10 A)

typ. 1 GHz

typ. 1 GHz

typ. 90 MHz

typ. 90 MHz

typ. 80 MHz

typ. 1.2 (

 200 MHz)

typ. 1.3 (

 150 MHz)

-

300 W (VSWR = 1.1)

300 W (VSWR = 1.1)

-

Dimensions W/H/D

31 mm / - / 33.5 mm

24 mm / 50 mm / 24 mm

25.4 mm / 96 mm / 25.4 mm

25.4 mm / 80 mm / 25.4 mm

25.4 mm / - / 93 mm

-40 °C ... 80 °C

-40 °C ... 80 °C

-40 °C ... 80 °C

-

-

-

N connector 50  

BNC 50 

BNC 50 

BNC 50 

BNC 75 

IEC 61643-21 / -

IEC 61643-21 / -

IEC 61643-21

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

CN-UB/E-BB

2817686

1

CN-UB/E

2763691

1

C-UB/E

2763701

10

C-UFB- 5DC/E

2782300

10

C-UFB- 5DC/E 75

2763604

10

C-UFB-24DC/E

2782313

10

Accessories

Accessories

Accessories

BNC-V 50

2805041

10

BNC-V 50

2805041

10

BNC-V 50

2805041

10

BNC-V 75

2805070

10

177

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for transceiver systems

For TETRA systems (380

 

MHz - 470

 

MHz), 

floating shield, connection: type N

For video systems, floating shield, coarse 

protection, connection: BNC

For video systems, floating shield, 

connection: BNC

phoenixcontact-protection-html.html
background image

λ

/

4

λ

/

4

Technical data

Technical data

Electrical data

IEC test classification/EN type

C2 / C3 / D1

C2 / C3 / D1

Rated current

5 A (25 °C)

-

Nominal discharge current I

n

 (8/20) µs

Core-Shield / Core-Ground

20 kA / 20 kA

50 kA / 50 kA

Total discharge current I

total 

(8/20)

 

µs

30 kA

-

Protection level U

p

Core-Shield / Core-Ground

 95 V (C2 - 10 kV / 5 kA) / 

 95 V (C2 - 10 kV / 5 kA)

- / 

 5 V (C1 - 1 kV/500 A)

- / 

Frequency range

380 MHz ... 470 MHz

0.8 GHz ... 2.25 GHz

Standing wave ratio SWR in a 50 

 system

typ. 1.05 (

 1.15)

typ. 1.2

Permissible RF power P

max

 800 W

 500 W

General data

Dimensions W/H/D

32 mm

 

/

 

32 mm

 

/

 

83 mm

25 mm

 

/

 

77.5 mm

Temperature range

-40 °C ... 90 °C

-40 °C ... 85 °C

Degree of protection in acc. with IEC 60529/EN 60529

IP68

IP68

Connection method

N Connector

N connector 50  

Test standards

IEC 61643-21

IEC 61643-21/A1 / EN 61643-21/A1

IEC 61643-21/A1 / EN 61643-21/A1

IEC 61643-21

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

COAXTRAB,

 protective adapter for antenna connections with 

Lambda/4 technology

Socket-socket

CN-LAMBDA/4-0.47-BB

2800021

1

CN-LAMBDA/4-2.25-BB

2801057

1

Connector-socket

CN-LAMBDA/4-0.47-SB

2800022

1

CN-LAMBDA/4-2.25-SB

2801056

1

Surge protection

 for UMTS and quad-band GSM antenna, with 

SMA plug and SMA coupling

Accessories

Accessories

Mounting plate

, for individual attachment to housing panels

straight

CN-UB/MP

2818135

10

angled

CN-UB/MP-90DEG-50

2803137

10

CN-UB/MP-90DEG-50

2803137

10

Adapter,

 insertion loss <0.3 dB at 2.4 GHz

N (male) -> SMA (female)

RAD-ADP-N/M-SMA/F

2917036

1

RAD-ADP-N/M-SMA/F

2917036

1

Adapter cable,

 pigtail, 50 

 impedance;

50 cm long, MCX (male) -> N (male)

RAD-PIG-EF316-MCX-N

2867681

1

RAD-PIG-EF316-MCX-N

2867681

1

30 cm long, N (female) -> SMA (male)

RAD-PIG-EF316-N-SMA

2867694

1

RAD-PIG-EF316-N-SMA

2867694

1

178

PHOENIX CONTACT

– For antennas with N and SMA connection
– High transmission capacities even for 

frequencies up to 6 GHz

– Maintenance-free surge protection with 

Lambda/4 technology

– Low protection level

Notes:

Attenuation characteristics at phoenixcontact.net/products

Antenna systems

Surge protection and interference suppression filters

Surge protection for transceiver systems

For TETRA systems (380 MHz - 470 MHz), 

grounded shield, connection: type N

For GSM systems (0.8 GHz-2.25 GHz), 

grounded shield, connection: type N

phoenixcontact-protection-html.html
background image

λ

/

4

λ

/

4

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

C2 / C3 / D1

C2 / C3 / D1

2 A (25 °C)

5 A (25 °C)

6 kA / 6 kA

50 kA / 50 kA

6 kA

60 kA

 5 V (C1 - 1 kV/500 A)

- / 

 5 V (C1 - 1 kV/500 A)

- / 

 11 V (6 kV / 3 kA)

0.8 GHz ... 2.25 GHz

2.4 GHz ... 5.9 GHz

 1.2 (0.8 GHz ... 2.25 GHz)

typ. 1.1 (

 1.20 (2.4 GHz...5.9 GHz))

 110 W (VSWR = 1.0)

 500 W

46.5 mm

 

/

 

25 mm

 

/

 

70 mm

26.1 mm

 

/

 

38 mm

 

/

 

60 mm

-40 °C ... 70 °C

-40 °C ... 90 °C

IP55

IP68

SMA connector

N Connector

Test standards

IEC 61643-21

IEC 61643-21/A1 / EN 61643-21/A1

IEC 61643-21/A1 / EN 61643-21/A1

IEC 61643-21

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

CN-LAMBDA/4-5.9-BB

2838490

1

CN-LAMBDA/4-5.9-SB

2800023

1

CSMA-LAMBDA/4-2.0-BS-SET

2800491

1

Accessories

Accessories

CN-UB/MP

2818135

10

CN-UB/MP-90DEG-50

2803137

10

CN-UB/MP-90DEG-50

2803137

10

RAD-ADP-N/M-SMA/F

2917036

1

RAD-PIG-EF316-MCX-N

2867681

1

179

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for transceiver systems

For GSM systems (0.8

 

GHz - 2.25

 

GHz), 

grounded shield, connection: SMA

For GSM and WiMAX systems 

(2.4 GHz - 5.9 GHz), grounded shield, 

connection: type N

phoenixcontact-protection-html.html
background image

OUT

IN

Technical data

Electrical data

IEC test classification/EN type

B2 / C1 / C2 / C3 / D1

Maximum continuous operating voltage U

C

20 V DC / -

Rated current

400 mA (25 °C)

Nominal discharge current I

n

 (8/20) µs

Core-Shield / Core-Ground

2.5 kA / 2.5 kA

Total discharge current I

total 

(8/20)

 

µs

10 kA

Output voltage limitation at 1 kV/µs

Core-Shield / Core-Ground

 80 V / 

 80 V

Cut-off frequency fg (3 dB)

In a 75 

 system

Symmetrical / Asymmetrical

- / > 2.5 GHz

General data

Dimensions W/H/D

145 mm / 72 mm / 32 mm

Temperature range

-25 °C ... 55 °C

Degree of protection in acc. with IEC 60529/EN 60529

IP40

Inflammability class in acc. with UL 94

-

Connection method

F connector

Test standards

IEC 61643-21+A1+A2 / DIN EN 61643-21 / DIN EN 50083-2

IEC 61643-21 / EN 61643-21 / EN 50083

Ordering data

Description

Type

Order No.

Pcs./Pkt.

COAXTRAB,

 protective device for antenna distributors/multi-

switches for insertion in the antenna line

C-SAT-BOX

2880561

1

COAXTRAB,

 

surge protection adapter

F connector

TV connector

Accessories

Adapter,

 to connect the C-SAT-BOX with antenna distributors with 

a pitch of 20 mm (e.g. ASTRO, SPAUN)

ADAPTER KOAX TYP F

2880972

5

Connection cable,

 to connect the C-SAT-BOX with the antenna 

distributor, length: 0.2 m

KBL-SAT/20

2880985

5

180

PHOENIX CONTACT

TV and radio systems

C-SAT-BOX

– Protection for antenna inputs in satellite 

receiver technology

– Used upstream of antenna distributor or 

multi-switch

– Analog and digital SAT signals
– Terrestrial antenna signals
– Direct wall mounting supported

C-TV-SAT

 and 

C-TV/HIFI

– Protective adapter for antenna 

connections

– Use on broadband cable or SAT 

connection

– TV (IEC) or F connector

Surge protection and interference suppression filters

Surge protection for transceiver systems

Notes:

Attenuation characteristics at phoenixcontact.net/products

For antenna distributor or multi-switch, 

grounded shield, connection: F

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Technical data

F-connector

TV connector

C1 / C2 / C3 / D1

C1 / C2 / C3 / D1

24 V DC / -

24 V DC / -

1.5 A (25 °C)

1.5 A (25 °C)

2.5 kA / -

2.5 kA / -

-

-

 600 V / -

 600 V / -

- / > 3 GHz

- / > 1 GHz

28 mm / 66 mm / 44 mm

-25 °C ... 75 °C

-

V-0

F connector

PAL-TV (IEC 169-2)

Test standards

IEC 61643-21+A1+A2 / DIN EN 61643-21 / DIN EN 50083-2

IEC 61643-21 / EN 61643-21 / EN 50083

Ordering data

Type

Order No.

Pcs./Pkt.

C-TV-SAT

2856993

1

C-TV/HIFI

2857002

1

Accessories

181

PHOENIX CONTACT

Surge protection and interference suppression filters

Surge protection for transceiver systems

For TV equipment and SAT systems, 

grounded shield, connection: F or TV (IEC)

phoenixcontact-protection-html.html
background image

182

PHOENIX CONTACT

Surge protection and interference suppression filters

Interference suppression filters

Reliable signals by means of 
interference suppression filters with 
integrated surge protection

Switching operations triggered 

mechanically or electronically generate 
pulse-like and high-frequency interference 
voltages. These voltages spread in an 
unimpeded manner across the cable 
network. All the devices within this cable 
network are affected. Data errors, 
uncontrolled functions, and system crashes 
can result, with data processing devices at 
particular risk.

Interference voltage filters for power 
supply units

Interference suppression filters limit 

conducted high-frequency interference 
voltages. Devices used in data processing or 
automation particularly benefit from a clean 
power supply. The end result is safe 
operation and reliable measured results. 
Thanks to the integrated surge protection, 
surge pulses are effectively limited and surge 
currents are safely discharged.

Your web code: 

#0149

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

183

PHOENIX CONTACT

Surge protection and interference suppression filters

Interference suppression filters

Mains interference filters - operating 
principle and range

Filtering of symmetrical disturbance 
variables

X

 - Interference voltages between the 

phase and neutral conductor are filtered.

Filtering of asymmetrical disturbance 
variables

Y

1

,Y

2

 - The opposite grounded 

interference voltages from phase to PE and 
from the neutral conductor to PE are 
filtered.

Operating range of filters

An attenuation curve diagram illustrates 

the effective operating range of mains 
interference filters. The relevant frequency-
dependent attenuation can be read 
according to the symmetrical or 
asymmetrical filter circuit.

Interference suppression filters with 
surge protection

Interference suppression filters with 

integrated surge protection have two tasks: 
they absorb surge voltages and also limit 
high-frequency interference voltages.

Versions are available for the power 

supply and for signal circuits.

phoenixcontact-protection-html.html
background image

I

N

OUT

L

L

N

N

N

O

14

11

1

2

CO

M

N

C

Total width 112 mm

Technical data

Electrical data

... 120AC

... 230AC

IEC test classification / EN Type

 

/

 

SPD Type

 

(UL)

III / T3 / 2CA

III / T3 / -

III / T3 / 2CA

III / T3 / 2CA

III / T3 / 2CA

Nominal voltage U

N

120

 

V

 

AC

 

(TN)

 

/

120

 

V

 

AC

 

(TT - only in use with 

RCD)

 

/

120

 

V

 

AC

 

(IT)

240

 

V

 

AC

 

(TN)

 

/

240

 

V

 

AC

 

(TT - only in use with 

RCD)

 

/

240

 

V

 

AC

 

(IT - only in use with 

RCD)

Maximum continuous operating voltage U

C

150 V AC

264 V AC

150 V AC

150 V AC

150 V AC

Nominal load current I

L

20 A (40°C)

20 A (40°C)

5 A (70°C)

10 A (60°C)

15 A (50 °C)

Combined surge U

OC

6 kV (3 kA)

10 kV (5 kA)

6 kV (3 kA)

6 kV (3 kA)

6 kV (3 kA)

Protection level U

p

 0.45 kV

 1 kV

Response time t

A

 25 ns

 25 ns

Backup fuse max. in acc. with IEC

20 A (MCB B/general purpose)

20 A (MCB B/general purpose)

20 A (MCB B/general purpose)

20 A (MCB 

Input attenuation a

I

Symmetrical

20 dB (

 100 kHz / 50 

)

20  dB  (

 100 kHz / 50 

)

20  dB  (

Asymmetrical

30 dB (

 1 MHz / 50 

)

30  dB  (

 1 MHz / 50 

)

30  dB  (

Inductance

2x 1 mH ±30 % (with current 

compensation)

2x 1 mH ±30 % (with current 

compensation)

General data

Dimensions W/H/D

112 mm / 93 mm / 79 mm

112 mm / 93 mm / 79 mm

112 mm / 93 mm / 79 mm

112 mm / 93 mm / 79 mm

Connection data solid/stranded/AWG

2.5 mm² ... 6 mm² / 2.5 mm² ... 4 mm² / 14 ... 10

2.5 mm² ... 6 mm² / 2.5 mm² ... 4 mm² / 14 .

Temperature range

-25 °C ... 70 °C

-25 °C ... 70 °C

-25 °C ... 70 °C

-25 °C ... 70 °C

-25 °C ... 70 °C

Inflammability class in acc. with UL 94

V-0

V-0

V-0

V-0

Test standards

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

Remote indication contact

PDT contact

Connection data solid/stranded/AWG

0.14 mm² ... 1.5 mm² / 0.14 mm² ... 1.5 mm² / 26 ... 16

0.14 mm² ... 1.5 mm² / 0.14 mm² ... 1.

Max. operating voltage

250 V AC / 250 V DC

250 V AC / 250 V DC

250 V AC / 250 V DC

250 V AC / 250 V DC

Max. operating current

1 A AC / 1 A DC

1 A AC / 1 A DC

1 A AC / 1 A DC

1 A AC / 1 A DC

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

SFP-TRAB,

 DIN-rail-mountable TVSS device protection with 

integrated mains interference filter and optical signaling

Nominal current: 20 A

120 V AC

SFP 1-20/120AC

2856702

1

Nominal current: 20 A

240 V AC

SFP 1-20/230AC

2859987

1

SFP-TRAB,

 DIN-rail-mountable device protection with integrated 

mains interference filter and optical signaling

Nominal current: 5 A

120 V AC

Nominal current: 10 A

120 V AC

Nominal current: 15 A

120 V AC

184

PHOENIX CONTACT

DIN-rail-mountable device protection 
with SFP-TRAB interference 
suppression filter

– Combined protective circuit for 

absorbing transient surge voltages and 
high-frequency interference voltages

– Thermal monitoring of the protective 

circuit

– Disconnection status signaled via floating 

remote indication contact

– Can be installed in industrial 

environments

Surge protection and interference suppression filters

Interference suppression filters

20

 

A nominal current

5

phoenixcontact-protection-html.html
background image

I

N

OUT

L

L

N

N

N

O

14

11

1

2

CO

M

N

C

I

N

OUT

L

L

N

N

N

O

14

11

1

2

CO

M

N

C

I

N

OUT

L

L

N

N

N

O

14

11

1

2

CO

M

N

C

For further information and full technical data, visit phoenixcontact.net/products

Total width 112 mm

Total width 112 mm

Total width 112 mm

Technical data

Technical data

Technical data

(UL)

III / T3 / 2CA

III / T3 / -

III / T3 / 2CA

III / T3 / 2CA

III / T3 / 2CA

120

 

V

 

AC

 

(TN)

 

/

120

 

V

 

AC

 

(TT - only in use with RCD)

 

/

120

 

V

 

AC

 

(IT)

120

 

V

 

AC

 

(TN)

 

/

120

 

V

 

AC

 

(TT - only in use with RCD)

 

/

120

 

V

 

AC

 

(IT)

120

 

V

 

AC

 

(TN)

 

/

120

 

V

 

AC

 

(TT - only in use with RCD)

 

/

120

 

V

 

AC

 

(IT)

150 V AC

264 V AC

150 V AC

150 V AC

150 V AC

20 A (40°C)

20 A (40°C)

5 A (70°C)

10 A (60°C)

15 A (50 °C)

6 kV (3 kA)

10 kV (5 kA)

6 kV (3 kA)

6 kV (3 kA)

6 kV (3 kA)

 0.45 kV

 0.45 kV

 0.45 kV

 25 ns

 25 ns

 25 ns

Backup fuse max. in acc. with IEC

20 A (MCB B/general purpose)

20 A (MCB B/general purpose)

20 A (MCB B/general purpose)

20 A (MCB B/general purpose)

20 A (MCB B/general purpose)

)

20  dB  (

 100 kHz / 50 

)

20  dB  (

 100 kHz / 50 

)

20  dB  (

 100 kHz / 50 

)

)

30  dB  (

 1 MHz / 50 

)

30  dB  (

 1 MHz / 50 

)

30  dB  (

 1 MHz / 50 

)

2x 1 mH ±30 % (with current compensation)

2x 1 mH ±30 % (with current compensation)

2x 1 mH ±30 % (with current compensation)

Dimensions W/H/D

112 mm / 93 mm / 79 mm

112 mm / 93 mm / 79 mm

112 mm / 93 mm / 79 mm

112 mm / 93 mm / 79 mm

Connection data solid/stranded/AWG

2.5 mm² ... 6 mm² / 2.5 mm² ... 4 mm² / 14 ... 10

2.5 mm² ... 6 mm² / 2.5 mm² ... 4 mm² / 14 ... 10

2.5 mm² ... 6 mm² / 2.5 mm² ... 4 mm² / 14 ... 10

2.5 mm² ... 6 mm² / 2.5 mm² ... 4 mm² / 14 ... 10

Temperature range

-25 °C ... 70 °C

-25 °C ... 70 °C

-25 °C ... 70 °C

-25 °C ... 70 °C

-25 °C ... 70 °C

Inflammability class in acc. with UL 94

V-0

V-0

V-0

V-0

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

IEC 61643-11 / EN 61643-11

PDT contact

PDT contact

PDT contact

Connection data solid/stranded/AWG

0.14 mm² ... 1.5 mm² / 0.14 mm² ... 1.5 mm² / 26 ... 16

0.14 mm² ... 1.5 mm² / 0.14 mm² ... 1.5 mm² / 26 ... 16

0.14 mm² ... 1.5 mm² / 0.14 mm² ... 1.5 mm² / 26 ... 16

0.14 mm² ... 1.5 mm² / 0.14 mm² ... 1.5 mm² / 26 ... 16

Max. operating voltage

250 V AC / 250 V DC

250 V AC / 250 V DC

250 V AC / 250 V DC

250 V AC / 250 V DC

1 A AC / 1 A DC

1 A AC / 1 A DC

1 A AC / 1 A DC

1 A AC / 1 A DC

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

SFP 1-5/120AC

2920667

1

SFP 1-10/120AC

2920670

1

SFP 1-15/120AC

2920683

1

185

PHOENIX CONTACT

Surge protection and interference suppression filters

Interference suppression filters

H

W

D

H

W

D

H

W

D

A nominal current

5

 

A nominal current

10

 

A nominal current

15

 

A nominal current

phoenixcontact-protection-html.html
background image

IN

OU

T

2

4

1

3

 

Technical data

Electrical data

IEC test classification/EN type

C1 / C3

Maximum continuous operating voltage U

C

38 V DC / 30 V AC

Rated current

500 mA (55°C)

Nominal discharge current I

n

 (8/20) µs

Core-Ground

350 A (per path)

Total discharge current I

total 

(8/20)

 

µs

700 A

Output voltage limitation at 1 kV/µs

Core-Ground

 70 V (per path)

Cut-off frequency fg (3 dB)

Asymmetrical in the 50 

 system

typ. 60 kHz

Resistance per path

0.5 

Inductance per path

typ. 100 µH

Capacity per path

typ. 130 nF

General data

Connection data solid/stranded/AWG

0.2 mm² ... 4 mm² / 0.2 mm² ... 2.5 mm² / 24 ... 12

Temperature range

-40 °C ... 85 °C

Degree of protection in acc. with IEC 60529/EN 60529

IP20

Inflammability class in acc. with UL 94

V-0

Test standards

IEC 61643-21 / EN 61643-21

Ordering data

Description

Voltage U

N

Type

Order No.

Pcs./Pkt.

TERMITRAB,

 spring-cage terminal block with integrated surge 

protection as a filter circuit and disconnect knives, for mounting on 

NS

 

35

24 V AC

TT-ST-M-SFP-24AC

2858946

10

Accessories

Cover

, for terminating a row of terminal blocks

TT-D-STTCO-BK

2858894

50

186

PHOENIX CONTACT

Notes:

Attenuation characteristics at phoenixcontact.net/products

H

W

D

– Combined protective circuit for 

absorbing transient surge voltages and 
high-frequency interference voltages

– With spring-cage connection
– Disconnection of signal circuits by 

disconnect knife

TERMITRAB

Surge protection and interference suppression filters

Interference suppression filters

Protection for two conductors with a common 

reference potential

phoenixcontact-protection-html.html
background image

IN

OU

T

2

4

1

3

IN

OU

T

2

4

1

3

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

Total width 25 mm

Total width 40 mm

Technical data

Technical data

Electrical data

NEF 1- 1

NEF 1- 3

NEF 1- 6

NEF 1-10

Rated voltage

240 V AC (L-N)

240 V AC (L-N)

240 V AC (L-N)

240 V AC (L-N)

Maximum continuous operating voltage U

C

264 V AC (L-N) / 

264 V AC (L-PE)

264 V AC (L-N) / 

264 V AC (L-PE)

264 V AC (L-N) / 

264 V AC (L-PE)

264 V AC (L-N) / 

264 V AC (L-PE)

Rated current

1 A (40°C)

3 A (40°C)

6 A (40°C)

10 A (40°C)

Backup fuse max. in acc. with IEC

1 A (gL)

3 A (gL)

6.3 A (gL/C)

10 A (gL)

Inductance

2x 10 mH

2x 2.7 mH

2x 2.7 mH

2x 1.8 mH

Input attenuation a

I

Symmetrical

> 65 dB (50 

/ 1 MHz)

> 55 dB (50 

/ 1 MHz)

> 80 dB (50 

/ 1 MHz)

> 80 dB (50 

/ 1 MHz)

Asymmetrical

> 45 dB (50 

/ 1 MHz)

> 35 dB (50 

/ 1 MHz)

> 40 dB (50 

/ 1 MHz)

> 40 dB (50 

/ 1 MHz)

General data

Dimensions W/H/D

25 mm / 79.4 mm / 84.15 mm

40 mm / 79.4 mm / 84.1 mm

Connection data solid/stranded/AWG

0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

Temperature range

-25 °C ... 100 °C (HMF)

-25 °C ... 100 °C (HMF)

Inflammability class in acc. with UL 94

V-2

V-2

Test standards

IEC 60939-2 / EN 60939-2

IEC 60939-2 / EN 60939-2

Ordering data

Ordering data

Description

Nominal load

current I

L

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

FILTRAB,

 interference suppression filter for single-phase current 

circuits, for mounting on NS

 

32 or NS

 

35...

1 A

NEF 1- 1

2794123

10

3 A

NEF 1- 3

2794110

10

6 A

NEF 1- 6

2783082

5

10 A

NEF 1-10

2788977

5

187

PHOENIX CONTACT

– Low pass filters for nominal currents of 

1 to 10 A

– For single-phase circuits
– DIN rail module

Notes:

Attenuation characteristics at phoenixcontact.net/products

H

W

D

H

W

D

FILTRAB

Surge protection and interference suppression filters

Interference suppression filters

1 A / 3 A nominal current

6 A / 10 A nominal current

phoenixcontact-protection-html.html
background image

188

PHOENIX CONTACT

Surge protection and interference suppression filters

Lightning current measurement

Lightning strikes cause devastating 

damage to buildings and systems. It is 
practically impossible for employees to 
continuously monitor exposed or large-
scale systems, which means that damage is 
detected too late.

Detecting lightning with the lightning 
monitoring system

The LM-S lightning monitoring system 

supports continuous monitoring. Lightning 
events are detected, evaluated, and 
remotely monitored via network access. By 
consolidating the system operating 
parameters and the measuring data, the 
system provides a better basis for making 
decisions regarding control and 
maintenance.

The LM-S lightning monitoring system 

consists of the following components:
– Sensor
– Connecting cable
– O/E  module
– Evaluation unit

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

189

PHOENIX CONTACT

Surge protection and interference suppression filters

Lightning current measurement

Faraday effect as a reliable measuring 
method

The internal measuring principle of the 

LM-S is based on the Faraday effect. 
Polarized light in a specific medium is 
rotated through a magnetic field over a 
defined length and measured.

The higher the amperage (i) generated by 

a lightning strike the greater the magnetic 
flux density (B) and, therefore, the rotation 
of the polarized light.

The lightning monitoring system detects 

this change in the light signal and uses this as 
the basis for the corresponding measured 
value results.

Remote monitoring in real time

The evaluation unit can be easily 

integrated into standard network systems 
via the RJ45 Ethernet interface. The data 
acquired can be accessed and the system 
can be configured via web interface, 
Modbus/TCP or OPC UA. The web 
interface is opened via the Internet browser 
on a PC connected to the system using IP 
addressing.

Detection and evaluation

The sensors are mounted on the lightning 

arrester cables. They record the magnetic 
field that occurs around the conductor due 
to the lightning surge current. The 
measured result is transmitted via fiber 
optics to the O/E module of the evaluation 
unit, where the optical signal is converted 
into an electrical signal. Based on the values 
obtained, the evaluation unit determines 
the lightning characteristics with their 
typical parameters, including, for example, 
the maximum lightning current strength, 
lightning current rate of rise, charge, and 
energy. These results can be forwarded to 
an available management system via the 
Ethernet interface.

phoenixcontact-protection-html.html
background image

Technical data

Detectable values

Maximum current strength

400 kA

FO interface

Connection method

SC-RJ socket with push-pull connector, IP67

General data

Ambient temperature (operation)

-30 °C ... 60 °C

Ambient temperature (storage/transport)

-40 °C ... 85 °C

Degree of protection

IP67

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Sensor

LM-S-LS-H

2800616

1

– Optical sensor for measuring lightning 

surge currents

– Can  be  retrofitted
– Resistant to humidity
– Good UV resistance

Sensor

Surge protection and interference suppression filters

Lightning current measurement

Sensor

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Connecting cable, variable

FOC-SJ:14-ST/HB02/...

1417723

1

Notes:

The specified connector configuration (see ordering example) 

must be used in order to use the connecting cable in the LM-S 

lightning monitoring system. 

Recommended length: 10 to 200 m

– HCS cable for connecting LM-S sensors 

to the O/E module

– Good UV resistance
– Good oil resistance

Connecting cable

Connecting cable for LM-S

Ordering example 

for

 

LM-S connecting 

cable with

 

variable cable length: 

Assembled connecting cable for the LM-S lightning monitoring 

system, with a metal push-pull connector, a B-FOC connector, and 

a cable length of 10 m.

Order No.

Length [m]

Max. 200 m

1417723

 / 

FOC-SJ:14-ST/HB02

/

10.0

Increments:

10.0 m ... 200 m = 1.0 m

190

PHOENIX CONTACT

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Operating voltage

24 V DC  ±4 V

Ethernet ports

Connection method

RJ45

Transmission speed

10/100 Mbps

FO interface

Interface

B-FOC (ST

®

)

Number of ports

3

Sensor interfaces

Connection method

Rack for plug-in I/O module

Remote indication contact

Connection method

M12 D-coded

Max. operating voltage

60 V DC

General data

Ambient temperature (operation)

-30 °C ... 60 °C

Degree of protection

IP20

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Evaluation unit with O/E module

LM-S-A/C-3S-ETH

2800618

1

– Complete module including O/E module 

for connecting up to three LM-S sensors

– Evaluation and storage of amperage, 

current rate of rise, charge, and specific 
energy

– Real-time analysis and exact time 

allocation

– Status and diagnostic indicators
– Communication via Ethernet
– Operation and configuration via web 

interface, Modbus/TCP, and OPC-UA

– Mounted on DIN rails

Evaluation unit

Surge protection and interference suppression filters

Lightning current measurement

Evaluation unit with O/E module

Technical data

FO interface

Interface

B-FOC (ST

®

)

Number of ports

3

General data

Ambient temperature (operation)

-30 °C ... 60 °C

Ambient temperature (storage/transport)

-40 °C ... 85 °C

Degree of protection

IP20

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Opto-electronic module

LM-S-C-3LS

2800617

1

191

PHOENIX CONTACT

– O/E module replacement for evaluation 

unit

– Connection of up to three LM-S sensors
– Status and diagnostic display via 

evaluation unit

Opto-electronic module

O/E module

phoenixcontact-protection-html.html
background image

192

PHOENIX CONTACT

Surge protection and interference suppression filters

Test devices

CHECKMASTER 2 – the intelligent 
test device for surge protective 
devices

Outdoor and indoor lightning protection 

must be regularly tested in accordance with 
normative requirements (IEC 62305) and 
official regulations. A basic visual check is 
not enough to identify damage to surge 
protective devices. Only an electrical check 
using the CHECKMASTER 2 produces 
meaningful results. The electrical check is 
performed with the aid of a programmable 
logic controller, a high-voltage source, and a 
constant current source. During the check, 
a program-controlled electrical test is 
performed on all the relevant components 
of the surge protective device. Thanks to 
the integrated database for surge protective 
devices, spark gaps, gas-filled surge 
protective devices, varistors, and 
suppressor diodes can be checked 
automatically. Surge protective devices that 
were previously damaged, surge protective 
devices that are nearing the electrical 
tolerance limits, and faulty surge protective 
devices can be safely identified.

In industries where high demands are 

placed on system availability, the 
CHECKMASTER 2 enables predictive 
maintenance to be carried out on surge 
protective devices. This provides additional 
security for failure-critical systems.

Your web code: 

#0147

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

193

PHOENIX CONTACT

Surge protection and interference suppression filters

Test devices

Easy selection

The CHECKMASTER 2 has a modular 

design. Corresponding test adapters are 
available for the various surge protective 
devices. Further information about the test 
adapters required can be found on the next 
page.

Convenient scanning

The barcodes on the surge protective 

devices present a fast and error-free 
solution for entering items. Plant-specific ID 
codes or user-defined designations can be 
entered via the color touch display or read 
from individually created barcode labels.

Fast logging and easy data export

The tests are documented in accordance 

with IEC 62305. The CHECKMASTER 2 
saves all test results to the internal memory 
with mains failure protection. The test 
reports are available via USB stick for 
convenient further processing in Office 
programs.

phoenixcontact-protection-html.html
background image

– Modular test device for pluggable surge 

protective devices from Phoenix Contact

– Easy and tool-free changing of test 

adapters

– Integrated programmable logic controller 

with high-voltage source and constant 
current source

– Automatic and program-controlled 

testing of surge protective devices

– Easy operation by means of color touch 

display with virtual keypad

– User interfaces: German, English
– Further languages available for download: 

French, Italian, Spanish, Portuguese, 
Turkish, Russian

– Barcode scanner for automatic 

identification of surge protective devices 
and for reading user-specific barcodes 
(e.g., plant identification codes)

– Plant identification codes can also be 

entered using the virtual keypad

– USB interface for connecting standard 

USB sticks

– Easy transfer of test reports to Office 

programs and easy system software 
update via USB stick

– No additional software required
– No data cable required
– Power supply cable with SCHUKO 

connector

– Robust plastic transport case; with 

removable lid

– Additional compartment for another test 

adapter

– Calibration certificate

Test adapters are not supplied as standard 

with the CHECKMASTER 2. The required 
test adapters must be ordered separately.

PA-CASE 2 transport case for test 
adapters

– Padded compartments for holding test 

adapters for the CHECKMASTER 2

– Test adapters are not supplied as standard 

with the PA-CASE 2

Free software for updating the 

CHECKMASTER 2 can be found in the 
download area on the Phoenix Contact 
homepage.

The CHECKMASTER 2 is designed for 

use in industrial environments (EMC: class 
A product) and may not meet the 
requirements for radiated disturbance 
variables for use in residential areas.

Nominal voltage U

N

Ambient temperature (operation)

5 °C ... 35 °C

Description

Test device,

 for testing the correct function of surge protective 

devices from Phoenix Contact; test adapters must be ordered 

separately

Transport case,

 to hold four test adapters

Test adapter,

 for testing the correct function of surge protective 

devices from Phoenix Contact:

FLASHTRAB FLT-CP/SEC and VALVETRAB VAL-CP/SEC

VALVETRAB VAL-MS

PLUGTRAB PT/PLT (width: 17.5

 

mm)

PLUGTRAB PT/PLT (width: 35

 

mm)

COMTRAB CTM

FLASHTRAB-SEC-HYBRID

PLUGTRAB UFBK/UAK

TERMITRAB complete

194

PHOENIX CONTACT

CHECKMASTER 2

Surge protection and interference suppression filters

Test devices

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Total width 432 mm

Technical data

100 V AC ... 240 V AC

Ambient temperature (operation)

5 °C ... 35 °C

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

CHECKMASTER 2

2905256

1

PA-CASE 2

2906272

1

CM 2-PA-FLT/VAL-CP/SEC

2905283

1

CM 2-PA-VAL-MS

2905265

1

CM 2-PA-PT/PLT

2905284

1

CM 2-PA-PT4/PLT3S

2907019

1

CM 2-PA-CTM

2905282

1

CM 2-PA-SEC-HYBRID

2907889

1

CM 2-PA-PT/A

2907891

1

CM 2-PA-TTC

2908707

1

195

PHOENIX CONTACT

Surge protection and interference suppression filters

Test devices

Test device

Transport case

Test adapter

phoenixcontact-protection-html.html
background image

Technical data

Electrical data

Maximum continuous operating voltage U

C

500 V AC

Nominal current I

N

-

Impulse discharge curr. I

imp

 (10/350) 

μ

s

Peak value

100 kA

General data

Dimensions W/H/D

17.7 mm / 89.8 mm / 65.5 mm

Connection data solid/stranded/AWG

0.5...35

 

mm²

 

 

- mm²

 

/ 20 ... 2

Temperature range

-40 °C ... 85 °C

Inflammability class in acc. with UL 94

V-0

Test standards

IEC

 

60947-7-1 / DIN EN 61643-11 / IEC 61643-1

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Feed-through terminal block

 with biconnect connecting terminal 

blocks as wiring aid for lightning current arrester and surge 

protective device applications.

DK-BIC-35

2749880

1

H

W

D

– For wiring mixed combinations of 

lightning current arresters and surge 
protective devices

– As a system extension for FLASHTRAB 

and VALVETRAB applications

– Practical wiring of all common 

applications

Feed-through terminal block

Surge protection and interference suppression filters

Accessories for surge protection

Feed-through terminal block

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Equipotential bonding strip

PAS-1

2765615

1

196

PHOENIX CONTACT

Equipotential bonding strip

– For main equipotential bonding according 

to DIN VDE 0100

– As well as for lightning protection 

equipotential bonding in acc. with 
DIN EN 62305
TRABTECH housing

– Use in harsh environmental conditions at 

the installation location

– Suitable for outdoor and indoor 

installation

Equipotential bonding and 
TRABTECH housing

Equipotential bonding strip

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Marking labels,

 corresponding material can be found on the 

website

Can be marked acc. to customer specifications

ZBN 18 CUS

0825059

1

UniCard materials,

 can be marked with BLUEMARK, 

corresponding material can be found on our website

UC-TM  6 GN

0818360

10

Zack marker strip, 5-section, unprinted, 

corresponding material can be found on our website

5-section

ZB 12:UNPRINTED

0812120

10

Continuous roll,

 width: 20

 

mm

Color: white

EML (20XE)R

0803452

1

Color: yellow

EML (20XE)R YE

0803453

1

– For clear and logical identification
– The multi-section ZB strips can be easily 

separated

– Can be marked with CMS computer 

marking system or by hand using B-STIFT

Marking material

Surge protection and interference suppression filters

Accessories for surge protection

For terminal width 6.2 mm

Marking label for the SEC product range

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Shield fast connection

For Ø 3-6 mm

SSA 3-6

2839295

10

For Ø 5-10 mm

SSA 5-10

2839512

10

Wiring bridge,

 for wiring applications with lightning current 

arresters and surge protective devices; these can be found on the 

website under the corresponding items

2-pos.

MPB 18/1- 2

2809209

10

3-pos.

MPB 18/1- 3

2809212

10

4-pos.

MPB 18/1- 4

2809225

10

5-pos.

MPB 18/1- 5

2817864

10

6-pos.

MPB 18/1- 6

2748564

10

8-pos.

MPB 18/1- 8

2748577

10

9-pos.

MPB 18/1- 9

2748580

10

12-pos.

MPB 18/1-12

2748593

10

57-pos.

MPB 18/1-57

2809238

1

Wiring bridge, 

35

 

mm²

6-pos.

MPB 18/1-6/35

2908705

10

8-pos.

MPB 18/1-8/35

2908704

10

197

PHOENIX CONTACT

– For connecting cable shielding to cable 

terminal points

– Easy assembly

Wiring bridges

– 1-phase with various numbers of 

positions

Shield fast connection and wiring 
bridges

Shield fast connection

Wiring bridges

phoenixcontact-protection-html.html
background image

198

PHOENIX CONTACT

phoenixcontact-protection-html.html
background image

 

Power supplies and UPS

 

 

 

Selection guides

 200

 

 

Power supplies

 204

 

 

QUINT POWER

 206

 

 

QUINT POWER, with protective coating

 216

 

 

TRIO POWER

 218

 

 

UNO POWER

 226

 

 

MINI POWER

 234

 

 

STEP POWER

 238

 

 

DC/DC converters

 246

 

 

QUINT DC/DC converters

 248

 

 

QUINT DC/DC converters, with protective coating

 254

 

 

MINI DC/DC converters

 256

 

 

Redundancy modules

 258

 

 

QUINT ORING

 260

 

 

QUINT S-ORING

 262

 

 

QUINT DIODE

 264

 

 

TRIO DIODE

 266

 

 

UNO DIODE

 267

 

 

STEP DIODE

 267

 

 

Accessories

 268

 

 

Uninterruptible power supplies for the control cabinet

 270

 

 

Selection guide for QUINT DC-UPS

 272

 

 

QUINT DC UPS

 274

 

 

Selection guide for QUINT AC-UPS

 278

 

 

QUINT AC-UPS

 280

 

 

TRIO AC-UPS

 282

 

 

Energy storage for QUINT UPS

 284

 

 

Accessories

 290

 

 

Selection guide for UPS modules

 292

 

 

UPS module with integrated energy storage

 294

 

 

UPS module with integrated power supply

 300

 

 

Energy storage for TRIO UPS and MINI UPS

 302

 

199

PHOENIX CONTACT

For superior system availability

The product ranges differ with regard to 

their design, performance, and functionality. 
Select the ideal solution based on your 
requirements:
– QUINT POWER – maximum 

functionality

– TRIO POWER – robust standard 

functionality

– UNO POWER – compact basic 

functionality
The product range is supplemented with 

designs tailor-made for specific applications:
– MINI POWER for measurement and 

control technology

– STEP POWER for installation distributors 

and flat control panels

Power supplies

Thanks to high-quality products featuring 

leading technology, our QUINT, TRIO, 
UNO, MINI, and STEP POWER product 
ranges optimally equip you for international 
competition.

DC/DC converters

Change the voltage level, regenerate the 

voltage at the end of long cables or enable 
the creation of independent supply systems 
with the QUINT and MINI DC/DC 
converters.

Redundancy modules

A redundant power supply system is the 

result of the parallel connection of two 
power supply units. Optimize this solution 
with the QUINT ORING and QUINT-S-
ORING redundancy modules and the 
QUINT, TRIO, UNO, and STEP diodes for 
superior system availability.

Uninterruptible power supplies (UPS) 
for control cabinets

IQ technology is the key to an intelligent 

power supply solution. The UPS monitors 
and optimizes the energy storage. Avoid 
interruptions when working with the 
intelligent UPS for non-stop power.

Your web code: 

#0150

Power supplies and UPS

phoenixcontact-protection-html.html
background image

QUINT POWER, with NFC technology, 1~

QUINT POWER, with NFC technology, 3~

24 DC / 5 A

24 DC / 10 A

24 DC / 20 A

24 DC / 5 A

24 DC / 10 A

24 DC / 20 A

Page 206

Page 206

Page 207

Page 208

Page 208

Page 209

QUINT POWER 1~

... 3~

24 DC / 3.5 A

24 DC / 40 A

24 DC / 40 A

Page 210

Page 210

Page 211

48 DC / 5 A

48 DC / 10 A

48 DC / 20 A

48 DC / 20 A

Page 213

Page 213

Page 213

Page 214

12 DC / 15 A

12 DC / 20 A

Page 212

Page 212

QUINT POWER, with protective coating 1~

... 3~

1 AC / 24 DC / 5 A CO 1 AC / 24 DC / 10 A CO 1 AC / 24 DC / 20 A CO 3 AC / 24 DC / 20 A CO

Page 216

Page 217

Page 217

Page 217

TRIO POWER 1~

24 DC / 3 A

24 DC / 5 A

24 DC / 5 A B+D

24 DC / 10 A

24 DC / 10 A B+D

24 DC / 20 A

Page 218

Page 219

Page 219

Page 220

Page 221

Page 221

48 DC / 5 A

48 DC / 10 A

Page 225

Page 225

12 DC / 5 A

12 DC / 10 A

Page 224

Page 225

TRIO POWER 3~

24 DC / 5 A

24 DC / 10 A

24 DC / 20 A

24 DC / 40 A

Page 222

Page 223

Page 223

Page 223

200

PHOENIX CONTACT

Power supplies and UPS

Product range overview

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

UNO POWER 1~

2~

24 DC / 30 W

24 DC / 60 W

24 DC / 90 W

24 DC / 100 W

24 DC / 150 W

24 DC / 240 W

24 DC / 90 W

Page 226

Page 226

Page 228

Page 227

Page 227

Page 227

Page 228

48 DC / 60 W

48 DC / 100 W

Page 232

Page 232

15 DC / 30 W

15 DC / 55 W

15 DC / 100 W

Page 231

Page 231

Page 231

12 DC / 30 W

12 DC / 55 W

12 DC / 100 W

Page 229

Page 229

Page 229

5 DC / 25 W

5 DC / 40 W

Page 230

Page 230

MINI POWER 1~

24 DC / 1.3 A

24 DC / 1.5 A

24 DC / 2 A

24 DC / 4 A

24 DC / 1.5 A EX

Page 234

Page 234

Page 235

Page 235

Page 237

5 DC / 3 A

10 - 15 DC / 2 A

24 DC / 100 W

Page 236

Page 236

Page 235

±15 DC / 1 A

10 - 15 DC / 8 A

Page 237

Page 237

STEP POWER 1~

24 DC / 0.5 A

24 DC / 0.75 A / FL

24 DC / 0.75 A

24 DC / 1.75 A

24 DC / 2.5 A

24 DC / 4.2 A

Page 238

Page 239

Page 239

Page 240

Page 240

Page 241

48 AC / 24 DC / 0.5 A

12 DC / 1.5 A / FL

12 DC / 1.5 A

12 DC / 3 A

5 DC / 6.5 A

24 DC / 100 W

Page 239

Page 244

Page 245

Page 245

Page 243

Page 241

12 DC / 1 A

12 DC / 5 A

48 DC / 2 A

Page 244

Page 245

Page 243

5 DC / 2 A

15 DC / 4 A

277 AC / 24 DC / 3.5 A

Page 242

Page 243

Page 241

Redundancy modules – QUINT

24 DC / 2x10 A

24 DC / 2x20 A

24 DC / 2x40

12 - 24 DC / 1x40 A

12 - 24 DC / 2x20 A

Page 260

Page 261

Page 261

Page 262

Page 264

12 - 24 DC / 1x40 A /+

48 DC / 2x20 A

Page 263

Page 265

Redundancy modules – TRIO

- UNO

- STEP

12 - 24 DC / 2x10 A

12 - 24 DC / 2x20 A

5 - 24 DC / 2x10 A

5 - 24 DC / 2x5 A

Page 266

Page 267

Page 267

Page 267

201

PHOENIX CONTACT

Power supplies and UPS

Product range overview

phoenixcontact-protection-html.html
background image

QUINT DC/DC converters

QUINT DC/DC converters, with protective coating

24 DC / 24 DC / 5 A

24 DC / 24 DC / 10 A

24 DC / 24 DC / 20 A  24 DC / 24 DC / 5 A / CO 60 -72 DC/24 DC/10 A/CO 24 DC / 24 DC / 10 A / CO 24 DC / 24 DC / 20 A / CO

Page 248

Page 248

Page 249

Page 254

Page 255

Page 254

Page 255

24 DC / 12 DC / 8 A

24 DC / 48 DC / 5 A

96-110 DC/24 DC/10 A/CO

Page 249

Page 249

Page 255

48 DC / 24 DC / 5 A

48 DC / 48 DC / 5 A

Page 252

Page 253

12 DC / 24 DC / 5 A

60 - 72 DC / 24 DC / 10 A

Page 250

Page 253

12 DC / 12 DC / 8 A

96 - 110 DC / 24 DC / 10 A

Page 251

Page 253

UNO DC/DC converters

MINI DC/DC converters

350-900 DC/24 DC/60 W

12 - 24 DC/24 DC/1 A

AC power module

Page 233

Page 256

Page 257

48 - 60 DC/24 DC/1 A

Page 257

12 - 24 DC/5 - 15 DC/2 A

Page 256

12 - 24 DC/48 DC / 0.7 A

Page 257

For frequency inverters

2 AC / 1 DC / 24 DC / 20 A 600 DC / 24 DC / 20 A

Page 215

Page 215

QUINT DC-UPS

24 DC / 5 A

24 DC / 10 A

24 DC / 20 A 

24 DC / 40 A

12 DC/5 A/24 DC/10 A

Page 274

Page 275

Page 275

Page 275

Page 276

QUINT AC-UPS

TRIO AC-UPS

1 AC / 1 AC / 500 VA

1 AC / 1 AC / 1 kVA

1 AC / 1 AC / 750 VA

Page 280

Page 281

Page 282

202

PHOENIX CONTACT

Power supplies and UPS

Product range overview

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

UPS-CAP for QUINT UPS

UPS-BAT/LI-ION for QUINT UPS

UPS-BAT/VRLA-WTR for QUINT UPS

24 DC / 10 A / 10 KJ

24 DC / 20 A / 20 KJ

24 DC / 120 WH

24 DC / 925 WH

24 DC / 13 AH

24 DC / 26 AH

Page 284

Page 284

Page 285

Page 285

Page 288

Page 288

UPS-BAT/VRLA for QUINT UPS

24 DC / 1.3 AH

24 DC / 3.4 AH

24 DC / 7.2 AH

24 DC / 12 AH

24 DC / 38 AH

Page 286

Page 286

Page 287

Page 287

Page 287

UPS with integrated QUINT, UNO, STEP energy storage

24 DC / 5 A / 1.3 AH

24 DC / 10 A / 3.4 AH

24 DC / 60 W

24 DC / 3 A

Page 294

Page 294

Page 299

Page 298

12 DC / 4 A

Page 298

QUINT BUFFER

QUINT CAP

24 DC / 20 A

24 DC / 40 A

24 DC / 5 A / 4 KJ

24 DC / 5 A / 8 KJ

Page 295

Page 295

Page 296

Page 297

MINI UPS with integrated power supply and 
energy storage

TRIO UPS with integrated power supply and 
energy storage

1 AC / 24 DC / 2 A

24 DC / 1.3 AH

24 DC / 0.8 AH

1 AC / 24 DC / 5 A

24 DC / 3.4 AH

24 DC / 7.2 AH

24 DC / 12 AH

Page 301

Page 302

Page 304

Page 300

Page 303

Page 303

Page 303

1 AC / 12 DC / 4 A

12 DC / 2.6 AH

12 DC / 1.6 AH

Page 301

Page 305

Page 305

203

PHOENIX CONTACT

Power supplies and UPS

Product range overview

phoenixcontact-protection-html.html
background image

204

PHOENIX CONTACT

Power supplies and UPS

Power supplies

Leading technology and high quality – 
power supplies for superior system 
availability.

Thanks to high-quality products featuring 

leading technology, with our power supply 
solutions from the QUINT, TRIO, UNO, 
MINI, and STEP POWER product ranges, 
you are optimally equipped to handle 
competitors on an international scale.

Functionality, performance class, and 

design are tailored to the demands of 
various different sectors and always offer 
the ideal solution. Choose from our wide 
range of power supplies and DC/DC 
converters.

QUINT POWER – maximum 
functionality

Cost-effective selective fuse protection 

with SFB Technology:

In order to trip miniature circuit breakers 

magnetically and quickly, power supplies 
must be able to supply several times the 
nominal current for a short period. With 
SFB (Selective Fuse Breaking) Technology, 
which supplies up to 6 times the nominal 
current for 15 ms, a dynamic power reserve 
is available. Faulty current paths are 
switched off selectively, the fault is located, 
and important system parts remain in 
operation.

Preventive function monitoring:
Comprehensive diagnostics are provided 

through constant monitoring of the output 
voltage and output current. This preventive 
function monitoring visualizes critical 
operating states, before errors can occur. 
The remote monitoring takes place by 
means of active switching outputs and 
floating relay contacts.

Power reserves:

– Easy system extension with static boost 

with sustained power of up to 125%

– Start heavy loads with dynamic boost, 

providing up to 200% power for 5 s
Adaptable:

– Signaling thresholds and characteristic 

curves that can be adjusted via NFC 
maximize system availability

TRIO POWER – robust standard 
functionality

The reliable supply of the loads under 

challenging ambient conditions is ensured by 
the power supply units, which feature an 
extremely robust electrical and mechanical 
design. TRIO POWER supplies up to 1.5 
times the nominal current for five seconds 
with the dynamic boost. Loads with high 
starting currents can therefore be started 
without other loads being affected by 
voltage dips.

UNO POWER – compact basic 
functionality

UNO POWER offers maximum energy 

efficiency thanks to high efficiency of up to 
94% and low idling losses below 0.3 W. The 
extremely high power density of up to 
325 W/dm

3

 enables a very compact design. 

Thanks to the wide range of products and 
the temperature range from -25°C to 
+70°C, the devices support flexible use.

Your web code: 

#0151

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

205

PHOENIX CONTACT

Power supplies and UPS

Power supplies

Power supplies – a comparison of the 
advantages

– QUINT POWER – maximum flexibility 

up to 1000 W

– TRIO POWER – standard functionality 

up to 1000 W

– UNO POWER – compact basic 

functionality up to 240 W

QUINT POWER

The QUINT POWER power supplies 

enable individual adjustment to the signaling 
thresholds and characteristic curves via the 
NFC interface.
– Quick tripping of standard circuit 

breakers with SFB Technology

– Easy system extension with static boost
– Starting  of  heavy  loads  with  dynamic 

boost

TRIO POWER

The TRIO POWER power supplies 

represent standard functionality, high 
quality, and reliability. They are therefore 
perfect for use in machine building.
– Robust  design
– Reliable supply of loads with high 

switch-on currents with the dynamic 
boost

– Time savings during installation thanks to 

Push-in connection technology

UNO POWER

The UNO POWER power supplies offer 

extremely compact basic functionality.
– The wide range of products covers all 

common voltage levels

– Save energy thanks to high efficiency and 

low idling losses

– Compact design saves space in the 

control cabinet

MINI POWER

MINI POWER power supplies in 

electronics housing for measurement and 
control technology.
– Maintenance-friendly connection 

technology: coded COMBICON 
connectors

– Active function monitoring with switching 

output for remote monitoring of the 
output voltage

STEP POWER

The STEP POWER power supplies are 

particularly suited to installation 
distributors and flat control panels.
– Maximum energy efficiency, thanks to 

incredibly low idling losses and a high 
degree of efficiency

– Flexible: snap onto the DIN rail or screw 

onto a level surface

phoenixcontact-protection-html.html
background image

N

FC

P

O

ut

OV

P

C

+

+

-

-

1

3

14

R

e

m

SG

nd

O

ut

 1

O

ut

 

2

a

ctive

P

FC

L

N

(

+

)

(

-

)

N

FC

P

O

ut

OV

P

C

+

+

-

-

1

3

14

R

e

m

SG

nd

O

ut

 1

O

ut

 

2

a

ctive

P

FC

-

L

N

(

+

)

(

-

)

 

 

 

 

 DNV GL 

 

Ex: 

 

 

 

 

 DNV GL 

 

Ex: 

Technical data

Technical data

Input data

Input voltage range

100 V AC ... 240 V AC -15

 

% ... +10

 

%

110 V DC ... 250 V DC -18

 

% ... +40

 

%

100 V AC ... 240 V AC -15

 

% ... +10

 

%

110 V DC ... 250 V DC -18

 

% ... +40

 

%

Frequency range (f

N

)

50 Hz ... 60 Hz -10 % ... +10 %

50 Hz ... 60 Hz -10 % ... +10 %

50 Hz ... 60 Hz -10 % ... +10 %

Current consumption (nominal load)

1.7 A (100 V AC)

 

/

 

1.5 A (120 V AC)

0.9 A (230 V AC)

 

/

 

0.8 A (240 V AC)

1.6 A (110 V DC)

 

/

 

0.7 A (250 V DC)

3.4 A (100 V AC)

 

/

 

2.8 A (120 V AC)

1.5 A (230 V AC)

 

/

 

1.5 A (240 V AC)

3 A (110 V DC)

 

/

 

1.3 A (250 V DC)

Inrush current limitation at 25°C / I

2

t

typ.

 

14 A

 

/

 

<

 

0.3 A

2

s

typ.

 

18 A

 

/

 

<

 

0.7 A

2

s

Mains buffering (I

N

, typ.)

 24 ms (120 V AC)

 

/

 ≥

 32 ms (230 V

 

AC)

 35 ms (120 V AC)

 

/

 ≥

 35 ms (230 V

 

AC)

Output data

Nominal output voltage

24 V DC

24 V DC

Output current I

N

 / I

Stat. Boost 

/ I

Dyn. Boost 

/ I

SFB

5 A / 6.25 A / 10 A (5 s) / 30 A (15 ms)

10 A / 12.5 A / 20 A (5 s) / 60 A (15 ms)

20 A / 25 A / 30 A (5 s) / 120 A (15 ms)

Magnetic circuit breaker tripping

A1...A4 / B2 / C1...C2 / Z1...Z4

A1...A6 / B2...B6 / C1...C3 / Z1...Z6

A1...A16 / B2...B13 / C1.

Can be connected in parallel/series

Yes / yes

Yes / yes

Max. power dissipation (no load/nominal load)

< 3 W (230 V AC) / < 16 W (230 V AC)

< 3 W (230 V AC) / < 17 W (230 V AC)

< 5 W (230

Efficiency

typ. 88.8 % (120 V AC)

 

/

 

typ. 89.2 % (230 V AC)

typ. 92.5 % (120 V AC)

 

/

 

typ. 93.4 % (230 V AC)

typ. 92.4 % (120 V AC)

Residual ripple

< 30 mV

PP

< 80 mV

PP

Signaling

LED signaling

DC OK, utilization indicator

DC OK, utilization indicator

DC OK, utilization indicator

Configurable signal output

Relay contact 13/14, Out 1 digital, Out 2 digital/analog

Relay contact 13/14, Out 1 digital, Out 2 digital/analog

Relay contact 13/14, Out 1 digital, Out 2 digital/analog

Signal options

I

Out

, U

Out

, P

Out

, U

In

 OK, Operating hours, Temp. OK, OVP

I

Out

, U

Out

, P

Out

, U

In

 OK, Operating hours, Temp. OK, OVP

I

General data

Weight / Dimensions W x H x D

0.7 kg / 36 x 130 x 125 mm

0.9 kg / 50 x 130 x 125 mm

1.3 kg / 70 x 130 x 125 mm

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Screw connection

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 30

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 30

 

-

 

12

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 30

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 30

 

-

 

12

0.2

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

1.5

 

mm² / 0.2

 

-

 

1.5

 

mm² / 24

 

-

 

16

0.2

 

-

 

1.5

 

mm² / 0.2

 

-

 

1.5

 

mm² / 24

 

-

 

16

0.2

Degree of protection / Protection class

IP20 / I

IP20 / I

MTBF (IEC 61709, SN 29500)

> 895000 h (40°C)

> 783000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ...

Ambient temperature (startup type tested)

-40 °C

-40 °C

Standards/regulations

Insulation voltage input/output

2.4 kV AC (routine test) / 4 kV AC (type test)

2.4 kV AC (routine test) / 4 kV AC (type test)

2.4 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Safety of power supply units up to 1100

 

V

DIN EN 61558-2-16

DIN EN 61558-2-16

Overvoltage category according to EN

 

62477-1

III

III

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

QUINT4-PS/1AC/24DC/5

2904600

1

QUINT4-PS/1AC/24DC/10

2904601

1

206

PHOENIX CONTACT

QUINT POWER, 1 AC, 24 V DC

– SFB Technology selectively trips standard 

circuit breakers; loads connected in 
parallel continue working

– Preventive function monitoring
– Signaling thresholds and characteristic 

curves that can be adjusted via NFC 
maximize system availability

– Easy system extension thanks to static 

boost; starting of difficult loads thanks to 
dynamic boost

– High noise immunity, thanks to integrated 

gas-filled surge arrester and mains failure 
buffer time in excess of 20 ms

QUINT POWER power supplies – 
maximum functionality

Power supplies and UPS

Power supplies

Power supply,

1 AC, 24 V DC, 5 A

Power supply,

1 AC, 24 V DC, 10 A

H

W

D

new

H

W

D

new

phoenixcontact-protection-html.html
background image

N

FC

P

O

ut

OV

P

C

+

+

-

-

1

3

14

R

e

m

SG

nd

O

ut

 1

O

ut

 

2

a

ctive

P

FC

-

L

N

(

+

)

(

-

)

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 DNV GL 

 

Ex: 

Technical data

100 V AC ... 240 V AC -15

 

% ... +10

 

%

110 V DC ... 250 V DC -18

 

% ... +40

 

%

)

50 Hz ... 60 Hz -10 % ... +10 %

50 Hz ... 60 Hz -10 % ... +10 %

50 Hz ... 60 Hz -10 % ... +10 %

6.8 A (100 V AC)

 

/

 

5.5 A (120 V AC)

2.8 A (230 V AC)

 

/

 

2.7 A (240 V AC)

6 A (110 V DC)

 

/

 

2.5 A (250 V DC)

typ.

 

11 A

 

/

 

<

 

0.4 A

2

s

 20 ms (120 V AC)

 

/

 ≥

 20 ms (230 V

 

AC)

24 V DC

5 A / 6.25 A / 10 A (5 s) / 30 A (15 ms)

10 A / 12.5 A / 20 A (5 s) / 60 A (15 ms)

20 A / 25 A / 30 A (5 s) / 120 A (15 ms)

Magnetic circuit breaker tripping

A1...A4 / B2 / C1...C2 / Z1...Z4

A1...A6 / B2...B6 / C1...C3 / Z1...Z6

A1...A16 / B2...B13 / C1...C6 / Z1...Z16

Yes / yes

Max. power dissipation (no load/nominal load)

< 3 W (230 V AC) / < 16 W (230 V AC)

< 3 W (230 V AC) / < 17 W (230 V AC)

< 5 W (230 V AC) / < 32 W (230 V AC)

typ. 93.4 % (230 V AC)

typ. 92.4 % (120 V AC)

 

/

 

typ. 94 % (230 V AC)

< 50 mV

PP

LED signaling

DC OK, utilization indicator

DC OK, utilization indicator

DC OK, utilization indicator

ital/analog

Relay contact 13/14, Out 1 digital, Out 2 digital/analog

 OK, Operating hours, Temp. OK, OVP

I

Out

, U

Out

, P

Out

, U

In

 OK, Operating hours, Temp. OK, OVP

Weight / Dimensions W x H x D

0.7 kg / 36 x 130 x 125 mm

0.9 kg / 50 x 130 x 125 mm

1.3 kg / 70 x 130 x 125 mm

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Screw connection

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 30

 

-

 

10

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 30

 

-

 

10

16

0.2

 

-

 

1.5

 

mm² / 0.2

 

-

 

1.5

 

mm² / 24

 

-

 

16

IP20 / I

> 673000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-40 °C

Insulation voltage input/output

2.4 kV AC (routine test) / 4 kV AC (type test)

2.4 kV AC (routine test) / 4 kV AC (type test)

2.4 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

DIN EN 61558-2-16

III

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

EN 61000-3-2

Ordering data

Type

Order No.

Pcs./Pkt.

QUINT4-PS/1AC/24DC/20

2904602

1

207

PHOENIX CONTACT

Power supplies and UPS

Power supplies

Power supply,

1 AC, 24 V DC, 20 A

H

W

D

new

phoenixcontact-protection-html.html
background image

N

FC

P

O

ut

OV

P

C

L1
L

2

L

3

+

+

-

-

(

-

)

(

+

)

1

3

14

R

e

m

SG

nd

O

ut

 1

O

ut

 

2

N

FC

P

O

ut

OV

P

C

+

+

-

-

1

3

14

R

e

m

SG

nd

O

ut

 1

O

ut

 

2

a

ctive

P

FC

-

I

n

r

ush

l

i

m

ite

r

L1
L

2

L

3

(

-

)

(

+

)

 

 

 

 

 

 DNV GL 

 

Ex: 

 

 

 

 

Technical data

Technical data

Input data

Input voltage range

3x 400 V AC ... 500 V AC -20 % ... +10 %

2x 400 V AC ... 500 V AC -10 % ... +10 %

± 300 V DC -25 % ... +30 %

3x 400 V AC ... 500 V AC -20 % ... +10 %

2x 400 V AC ... 500 V AC -10 % ... +10 %

± 260 V DC ... 300 V DC -13

 

%

 

...

 

+30

 

%

Frequency range (f

N

)

50 Hz ... 60 Hz -10 % ... +10 %

50 Hz ... 60 Hz -10 % ... +10 %

50 Hz ... 60 Hz -10 % ... +10 %

Current consumption (nominal load)

3x 0.6 A (400 V AC)

 

/

 

3x 0.5 A (480 V AC)

2x 0.9 A (400 V AC)

 

/

 

2x 0.8 A (480 V AC)

0.3 A (

 300 V DC)

3x 0.5 A (400 V AC)

 

/

 

3x 0.4 A (480 V AC)

2x 0.8 A (400 V AC)

 

/

 

2x 0.9 A (480 V AC)

0.7 A (

 

260

 

V

 

DC)

 

/

 

0.6 A (

 300 V DC)

Inrush current limitation at 25°C / I

2

t

typ.

 

10 A

 

/

 

<

 

0.2 A

2

s

typ.

 

3 A

 

/

 

<

 

0.1 A

2

s

Mains buffering (I

N

, typ.)

 28 ms (3x 400 V AC)

 

/

 ≥

 40 ms (3x 480 V AC)

 22 ms (3x 400 V AC)

 

/

 ≥

 22 ms (3x 480 V AC)

Output data

Nominal output voltage

24 V DC

24 V DC

Output current I

N

 / I

Stat. Boost 

/ I

Dyn. Boost 

/ I

SFB

5 A / 6.25 A / 10 A (5 s) / 30 A (15 ms)

10 A / 12.5 A / 20 A (5 s) / 60 A (15 ms)

20 A / 25 A / 30 A (5 s) / 120 A (15 ms)

Magnetic circuit breaker tripping

A1...A4 / B2 / C1...C2 / Z1...Z4

A1...A6 / B2...B6 / C1...C3 / Z1...Z6

A1...A16 / B2...B13 / C1.

Can be connected in parallel/series

Yes / yes

Yes / yes

Max. power dissipation (no load/nominal load)

< 4 W (480 V AC) / < 17 W (480 V AC)

< 5 W (480 V AC) / < 20 W (480 V AC)

< 7 W (480

Efficiency

typ. 89 % (400 V AC)

 

/

 

typ. 87.5 % (480 V AC)

typ. 93 % (400 V AC)

 

/

 

typ. 92.6 % (480 V AC)

typ. 93.9 % (400 V AC)

Residual ripple

< 30 mV

PP

< 75 mV

PP

Signaling

LED signaling

DC OK, utilization indicator

DC OK, utilization indicator

DC OK, utilization indicator

Configurable signal output

Relay contact 13/14, Out 1 digital, Out 2 digital/analog

Relay contact 13/14, Out 1 digital, Out 2 digital/analog

Relay contact 13/14, Out 1 digital, Out 2 digital/analog

Signal options

I

Out

, U

Out

, P

Out

, U

In

 OK, Operating hours, Temp. OK, OVP

I

Out

, U

Out

, P

Out

, U

In

 OK, Operating hours, Temp. OK, OVP

I

General data

Weight / Dimensions W x H x D

0.6 kg / 36 x 130 x 125 mm

0.9 kg / 50 x 130 x 125 mm

1.1 kg / 70 x 130 x 125 mm

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Screw connection

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 30

 

-

 

10

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 30

 

-

 

10

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 30

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 30

 

-

 

12

0.2

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

1.5

 

mm² / 0.2

 

-

 

1.5

 

mm² / 24

 

-

 

16

0.2

 

-

 

1.5

 

mm² / 0.2

 

-

 

1.5

 

mm² / 24

 

-

 

16

0.2

Degree of protection / Protection class

IP20 / I

IP20 / I

MTBF (IEC 61709, SN 29500)

> 914000 h (40°C)

> 654000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ...

Ambient temperature (startup type tested)

-40 °C

-40 °C

Standards/regulations

Insulation voltage input/output

2.4 kV AC (routine test) / 4 kV AC (type test)

2.4 kV AC (routine test) / 4 kV AC (type test)

2.4 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Safety of power supply units up to 1100

 

V

DIN EN 61558-2-16

DIN EN 61558-2-16

Overvoltage category according to EN

 

62477-1

III

III

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

QUINT4-PS/3AC/24DC/5

2904620

1

QUINT4-PS/3AC/24DC/10

2904621

1

208

PHOENIX CONTACT

QUINT POWER, 3 AC, 24 V DC

– SFB Technology selectively trips standard 

circuit breakers; loads connected in 
parallel continue working

– Preventive function monitoring
– Signaling thresholds and characteristic 

curves that can be adjusted via NFC 
maximize system availability

– Easy system extension thanks to static 

boost; starting of difficult loads thanks to 
dynamic boost

– High noise immunity, thanks to integrated 

gas-filled surge arrester and mains failure 
buffer time in excess of 20 ms

QUINT POWER power supplies – 
maximum functionality

Power supplies and UPS

Power supplies

Power supply,

3 AC, 24 V DC, 5 A

Power supply,

3 AC, 24 V DC, 10 A

H

W

D

new

H

W

D

new

phoenixcontact-protection-html.html
background image

N

FC

P

O

ut

OV

P

C

+

+

-

-

1

3

14

R

e

m

SG

nd

O

ut

 1

O

ut

 

2

a

ctive

P

FC

-

I

n

r

ush

l

i

m

ite

r

L1
L

2

L

3

(

-

)

(

+

)

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

Technical data

3x 400 V AC ... 500 V AC -20 % ... +10 %

2x 400 V AC ... 500 V AC -10 % ... +10 %

± 260 V DC ... 300 V DC -13

 

%

 

...

 

+30

 

%

)

50 Hz ... 60 Hz -10 % ... +10 %

50 Hz ... 60 Hz -10 % ... +10 %

50 Hz ... 60 Hz -10 % ... +10 %

3x 1 A (400 V AC)

 

/

 

3x 0.9 A (480 V AC)

2x 1.7 A (400 V AC)

 

/

 

2x 1.3 A (480 V AC)

1.23 A (

 

260

 

V

 

DC)

 

/

 

1.1 A (

 300 V DC)

typ.

 

2 A

 

/

 

<

 

0.1 A

2

s

 25 ms (3x 400 V AC)

 

/

 ≥

 25 ms (3x 480 V AC)

24 V DC

5 A / 6.25 A / 10 A (5 s) / 30 A (15 ms)

10 A / 12.5 A / 20 A (5 s) / 60 A (15 ms)

20 A / 25 A / 30 A (5 s) / 120 A (15 ms)

Magnetic circuit breaker tripping

A1...A4 / B2 / C1...C2 / Z1...Z4

A1...A6 / B2...B6 / C1...C3 / Z1...Z6

A1...A16 / B2...B13 / C1...C6 / Z1...Z16

Yes / yes

Max. power dissipation (no load/nominal load)

< 4 W (480 V AC) / < 17 W (480 V AC)

< 5 W (480 V AC) / < 20 W (480 V AC)

< 7 W (480 V AC) / < 33 W (480 V AC)

typ. 92.6 % (480 V AC)

typ. 93.9 % (400 V AC)

 

/

 

typ. 93.8 % (480 V AC)

< 60 mV

PP

LED signaling

DC OK, utilization indicator

DC OK, utilization indicator

DC OK, utilization indicator

ital/analog

Relay contact 13/14, Out 1 digital, Out 2 digital/analog

 OK, Operating hours, Temp. OK, OVP

I

Out

, U

Out

, P

Out

, U

In

 OK, Operating hours, Temp. OK, OVP

Weight / Dimensions W x H x D

0.6 kg / 36 x 130 x 125 mm

0.9 kg / 50 x 130 x 125 mm

1.1 kg / 70 x 130 x 125 mm

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Screw connection

10

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 30

 

-

 

10

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 30

 

-

 

10

16

0.2

 

-

 

1.5

 

mm² / 0.2

 

-

 

1.5

 

mm² / 24

 

-

 

16

IP20 / I

> 638000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-40 °C

Insulation voltage input/output

2.4 kV AC (routine test) / 4 kV AC (type test)

2.4 kV AC (routine test) / 4 kV AC (type test)

2.4 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

DIN EN 61558-2-16

III

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

EN 61000-3-2

Ordering data

Type

Order No.

Pcs./Pkt.

QUINT4-PS/3AC/24DC/20

2904622

1

209

PHOENIX CONTACT

Power supplies and UPS

Power supplies

Power supply,

3 AC, 24 V DC, 20 A

H

W

D

new

phoenixcontact-protection-html.html
background image

13

I < I

N

DC

 

O

K

14

L (+)

N (-)

13

I < I

N

DC

 

O

K

14

L (+)

N (-)

a

ctive

PF

C

 

 

 

 

 

 DNV GL 

 

 

 

 

Ex: 

 

 

 

 

 

 DNV GL 

 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

100 V AC ... 240 V AC

120 V DC ... 300 V DC

Input voltage range

85 V AC ... 264 V AC

90 V DC ... 350 V DC

85 V AC ... 264 V AC

90 V DC ... 300 V DC

Frequency range

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

1.4 A (120 V AC) / 0.8 A (230 V AC)

8.8 A (120 V AC) / 4.6 A (230 V AC)

Inrush current limitation at 25°C / I

2

t

<

 

20 A

 

/

 

<

 

2 A

2

s

<

 

15 A

 

/

 

<

 

1.7 A

2

s

Mains buffering (I

N

, typ.)

> 20 ms (120 V AC)

 

/

 

> 80 ms (230 V AC)

> 35 ms (120 V AC)

 

/

 

> 35 ms (230 V AC)

Output data

Nominal output voltage

24 V DC ±1

 

%

24  V  DC  ±1

 

%

Setting range of the output voltage (U

Set

)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

Output current / Power

 

Boost / SFB (12 ms)

3.5 A / 4 A / 15 A

40 A / 45 A / 215 A

Magnetic circuit breaker tripping

B2

B2 / B4 / B6 / B10 / B16 / B25 / C2 / C4 / C6 / C13

Can be connected in parallel/series

Yes / yes

Yes / yes

Max. power dissipation (no load/nominal load)

3.5 W / 11 W

14 W / 80 W

Efficiency

> 88 % (for 230 V AC and nominal values)

> 92 % (for 230 V AC and nominal values)

Residual ripple

< 50 mV

PP

< 30 mV

PP

Signaling

Signaling DC OK

LED, active switching output, relay contact

LED, active switching output, relay contact

Boost signaling

LED, active switching output

LED, active switching output

General data

Weight / Dimensions W x H x D

0.5 kg / 32 x 130 x 125 mm

3.3 kg / 180 x 130 x 125 mm

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Plug-in screw connection

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 20

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 14

 

-

 

10

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 20

 

-

 

12

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 8

 

-

 

6

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 20

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 24

 

-

 

10

Degree of protection / Protection class

IP20 / I

IP20 / I

MTBF (IEC 61709, SN 29500)

> 820000 h (40°C)

> 530000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

Standards/regulations

Insulation voltage input/output

2 kV AC (routine test) / 4 kV AC (type test)

2 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410 , DIN VDE 0106-101

Medical standard

IEC 60601-1, 2 x MOOP

IEC 60601-1, 2 x MOOP

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

QUINT-PS/1AC/24DC/ 3.5

2866747

1

QUINT-PS/1AC/24DC/40

2866789

1

210

PHOENIX CONTACT

QUINT POWER, 1 AC, 24 V DC

– Fast tripping of standard miniature circuit 

breakers with SFB (Selective Fuse 
Breaking) Technology dynamic power 
reserve with up to 6 times the nominal 
current for 12 ms

– Reliable starting of heavy loads with the 

static Power Boost power reserve with 
up to 1.5 times the nominal current

– Preventive function monitoring
– Flexible thanks to input voltage ranges for 

AC and DC voltages

– Approved for semiconductor production 

according to SEMI F47-0706

H

W

D

H

W

D

QUINT POWER power supplies – 
maximum functionality

Power supplies and UPS

Power supplies

Power supply,

1 AC, 24 V DC, 3.5 A

Power supply,

1 AC, 24 V DC, 40 A

phoenixcontact-protection-html.html
background image

L1 (+)

L2

L3 (-)

13

I < I

N

DC O

K

14

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 DNV GL 

 

 

 

 

Ex: 

Technical data

Input data

Nominal input voltage range

3x 400 V AC ... 500 V AC

Input voltage range

3x 320 V AC ... 575 V AC

2x 360 V AC ... 575 V AC

450 V DC ... 800 V DC

Frequency range

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

3x 2.1 A (400 V AC) / 3x 1.7 A (500 V

 

AC)

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

<

 

1 A

2

s

Mains buffering (I

N

, typ.)

> 25 ms (400 V AC)

 

/

 

> 35 ms (500 V

 

AC)

Output data

Nominal output voltage

24 V DC ±1

 

%

Setting range of the output voltage (U

Set

)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

Output current / Power

 

Boost / SFB (12 ms)

40 A / 45 A / 215 A

Magnetic circuit breaker tripping

B2 / B4 / B6 / B10 / B16 / B25 / C2 / C4 / C6 / C13

Can be connected in parallel/series

Yes / yes

Max. power dissipation (no load/nominal load)

18 W / 63 W

Efficiency

> 94 % (at 400 V AC and nominal values)

Residual ripple

< 40 mV

PP

Signaling

Signaling DC OK

LED, active switching output, relay contact

Boost signaling

LED, active switching output

General data

Weight / Dimensions W x H x D

2.5 kg / 96 x 130 x 176 mm

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 18

 

-

 

10

Output connection data (solid/stranded/AWG)

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 8

 

-

 

6

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 18

 

-

 

10

Degree of protection / Protection class

IP20 / I

MTBF (IEC 61709, SN 29500)

> 500000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

Standards/regulations

Insulation voltage input/output

2 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV) / Overvoltage category III

Safe isolation

DIN VDE 0100-410 , DIN VDE 0106-101

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1 

(3-wire + PE, star net) , UL ANSI/ISA-12.12.01 Class I, Division 2, 

Groups A, B, C, D (Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

QUINT-PS/3AC/24DC/40

2866802

1

211

PHOENIX CONTACT

H

W

D

QUINT POWER, 3 AC, 24 V DC

– High system availability even in the event 

of a permanent phase failure

– High surge strength of up to 6 kV thanks 

to integrated gas-filled surge arresters

– Fast tripping of standard miniature circuit 

breakers with SFB (Selective Fuse 
Breaking) Technology dynamic power 
reserve with up to 6 times the nominal 
current for 12 ms

– Reliable starting of heavy loads with the 

static Power Boost power reserve with 
up to 1.5 times the nominal current

– Preventive function monitoring
– Flexible thanks to input voltage ranges for 

AC and DC voltages

– Approved for semiconductor production 

according to SEMI F47-0706

QUINT POWER power supplies – 
maximum functionality

Power supplies and UPS

Power supplies

Power supply,

3 AC, 24 V DC, 40 A

phoenixcontact-protection-html.html
background image

13

I < I

N

DC

 

O

K

14

L (+)

N (-)

a

ctive

PF

C

13

I < I

N

DC

 

O

K

14

L (+)

N (-)

a

ctive

PF

C

 

 

 

 

 

Ex: 

 

 

 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

100 V AC ... 240 V AC

Input voltage range

85 V AC ... 264 V AC

90 V DC ... 350 V DC

85 V AC ... 264 V AC

90 V DC ... 350 V DC

Frequency range

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

1.9 A (120 V AC) / 0.9 A (230 V AC)

2.4 A (120 V AC) / 1.4 A (230 V AC)

2.8 A (120 V AC) / 1.2 

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

<

 

1.5 A

2

s

<

 

20 A

 

/

 

<

 

3.2 A

2

s

Mains buffering (I

N

, typ.)

> 65 ms (120 V AC)

 

/

 

> 65 ms (230 V AC)

> 40 ms (120 V AC)

 

/

 

> 40 ms (230 V AC)

> 40 ms (120 V AC)

Output data

Nominal output voltage

12 V DC ±1

 

%

12  V  DC  ±1

 

%

Setting range of the output voltage (U

Set

)

5 V DC ... 18 V DC (> 12 V

 

DC, constant capacity restricted)

5 V DC ... 18 V DC (> 12 V

 

DC, constant capacity restricted)

30 V DC ... 56 V DC (> 48

Output current / Power

 

Boost / SFB (12 ms)

15 A / 16 A / -

20 A / 26 A / -

Magnetic circuit breaker tripping

B2 / B4 / B6 / C2 / C4

B2 / B4 / B6 / B10 / C2 / C4 / C6

B2 / B4 / C2

B2 / B4 / B6 / C2 / C4

B2 / 

Can be connected in parallel/series

Yes / yes

Yes / yes

Max. power dissipation (no load/nominal load)

5 W / 21 W

6 W / 29 W

Efficiency

> 89 % (for 230 V AC and nominal values)

> 90 % (for 230 V AC and nominal values)

> 92.5 % (for 230 V AC and nominal va

Residual ripple

< 10 mV

PP

< 50 mV

PP

Signaling

Signaling DC OK

LED, active switching output, relay contact

LED, active switching output, relay contact

LED, active switching outp

Boost signaling

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

General data

Weight / Dimensions W x H x D

1.1 kg / 60 x 130 x 125 mm

1.5 kg / 90 x 130 x 125 mm

1.1 kg / 60 x 130 x 125 mm

1.7 kg / 90 x 130 x 

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Plug-in screw connection

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 18

 

-

 

10

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 12

 

-

 

10

0.2

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 18

 

-

 

10

0.2

Degree of protection / Protection class

IP20 / I

IP20 / I

MTBF (IEC 61709, SN 29500)

> 570000 h (40°C)

> 600000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

2 kV AC (routine test) / 4 kV AC (type test)

2 kV AC (routine test) / 4 kV AC (type test)

2 kV AC 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IE

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410

Medical standard

IEC 60601-1, 2 x MOOP

IEC 60601-1, 2 x MOOP

IEC 60601-1, 2 x MOOP

IEC 60601-1, 2 x MOOP

-

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

QUINT-PS/1AC/12DC/15

2866718

1

QUINT-PS/1AC/12DC/20

2866721

1

212

PHOENIX CONTACT

QUINT POWER, 1 AC, 12 and 
48 V DC

– Quick tripping of standard circuit 

breakers

– Reliable starting of heavy loads
– Preventive function monitoring
– Flexible thanks to input voltage ranges for 

AC and DC voltages

– Approved for semiconductor production 

according to SEMI F47-0706: 12 V DC 
and 48 V DC, 5 A and 10 A

– Adjustable output voltage of 5 to 

18 V DC, or 30 to 56 V DC

QUINT POWER power supplies – 
maximum functionality

Power supplies and UPS

Power supplies

Power supply,

1 AC, 12 V DC, 15 A

Power supply,

1 AC, 12 V DC, 20 A

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

13

I < I

N

DC

 

O

K

14

L (+)

N (-)

a

ctive

PF

C

13

I < I

N

DC

 

O

K

14

L (+)

N (-)

a

ctive

PF

C

13

I < I

N

DC

 

O

K

14

L (+)

N (-)

a

ctive

PF

C

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

Ex: 

 

 

 

 

 DNV GL 

Ex: 

 

 

 

 DNV GL 

Technical data

Technical data

Technical data

100 V AC ... 240 V AC

100 V AC ... 240 V AC

100 V AC ... 240 V AC

120 V DC ... 300 V DC

85 V AC ... 264 V AC

90 V DC ... 350 V DC

85 V AC ... 264 V AC

90 V DC ... 350 V DC

85 V AC ... 264 V AC

90 V DC ... 300 V DC

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

1.9 A (120 V AC) / 0.9 A (230 V AC)

2.4 A (120 V AC) / 1.4 A (230 V AC)

2.8 A (120 V AC) / 1.2 A (230 V AC)

5.1 A (120 V AC) / 2.3 A (230 V AC)

8.7 A (120 V AC) / 4.5 A (230 V AC)

<

 

15 A

 

/

 

<

 

1.5 A

2

s

<

 

20 A

 

/

 

<

 

3.2 A

2

s

<

 

15 A

 

/

 

<

 

1.6 A

2

s

> 40 ms (230 V AC)

> 40 ms (120 V AC)

 

/

 

> 40 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 20 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 22 ms (230 V AC)

48 V DC ±1

 

%

48  V  DC  ±1

 

%

48 V DC  ±1

 

%

DC, constant capacity restricted)

30 V DC ... 56 V DC (> 48

 

V

 

DC, constant capacity restricted)

30 V DC ... 56 V DC (> 48

 

V

 

DC, constant capacity restricted)

30 V DC ... 56 V DC (> 48

 

V

 

DC, constant capacity restricted)

5 A / 7.5 A / 30 A

10 A / 13 A / 60 A

20 A / 22.5 A / 100 A

Magnetic circuit breaker tripping

B2 / B4 / B6 / C2 / C4

B2 / B4 / B6 / B10 / C2 / C4 / C6

B2 / B4 / C2

B2 / B4 / B6 / C2 / C4

B2 / B4 / B6 / B10 / C2 / C4 / C6

Yes / No

Yes / yes

Yes / yes

7 W / 21 W

16 W / 41 W

12 W / 74 W

Efficiency

> 89 % (for 230 V AC and nominal values)

> 90 % (for 230 V AC and nominal values)

> 92.5 % (for 230 V AC and nominal values)

> 93 % (for 230 V AC and nominal values)

> 93 % (for 230 V AC and nominal values)

< 50 mV

PP

< 80 mV

PP

< 50 mV

PP

Signaling DC OK

LED, active switching output, relay contact

LED, active switching output, relay contact

LED, active switching output, relay contact

LED, active switching output, relay contact

LED, active switching output, relay contact

Boost signaling

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

Weight / Dimensions W x H x D

1.1 kg / 60 x 130 x 125 mm

1.5 kg / 90 x 130 x 125 mm

1.1 kg / 60 x 130 x 125 mm

1.7 kg / 90 x 130 x 125 mm

3.3 kg / 180 x 130 x 125 mm

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Plug-in screw connection

Screw connection

Screw connection

10

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 18

 

-

 

10

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 14

 

-

 

10

10

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 12

 

-

 

10

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 8

 

-

 

6

10

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 18

 

-

 

10

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 24

 

-

 

10

IP20 / I

IP20 / I

IP20 / I

> 530000 h (40°C)

> 630000 h (40°C)

> 523000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

ype test)

2 kV AC (routine test) / 4 kV AC (type test)

2 kV AC (routine test) / 4 kV AC (type test)

2 kV AC (routine test) / 4 kV AC (type test)

2 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

Medical standard

IEC 60601-1, 2 x MOOP

IEC 60601-1, 2 x MOOP

IEC 60601-1, 2 x MOOP

IEC 60601-1, 2 x MOOP

-

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

QUINT-PS/1AC/48DC/ 5

2866679

1

QUINT-PS/1AC/48DC/10

2866682

1

QUINT-PS/1AC/48DC/20

2866695

1

213

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

Power supply,

1 AC, 48 V DC, 5 A

Power supply,

1 AC, 48 V DC, 10 A

Power supply,

1 AC, 48 V DC, 20 A

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

L1 (+)

L2

L3 (-)

13

I < I

N

DC O

K

14

 

 

 

 

 

Ex: 

Technical data

Input data

Nominal input voltage range

3x 400 V AC ... 500 V AC

Input voltage range

3x 320 V AC ... 575 V AC

2x 360 V AC ... 575 V AC

450 V DC ... 800 V DC

Frequency range

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

3x 2.1 A (400 V AC) / 3x 1.7 A (500 V

 

AC)

Inrush current limitation at 25°C / I

2

t

<

 

20 A

 

/

 

<

 

1 A

2

s

Mains buffering (I

N

, typ.)

> 25 ms (400 V AC)

 

/

 

> 35 ms (500 V

 

AC)

Output data

Nominal output voltage

48 V DC ±1

 

%

Setting range of the output voltage (U

Set

)

30 V DC ... 56 V DC (> 48

 

V

 

DC, constant capacity restricted)

Output current / Power

 

Boost / SFB (12 ms)

20 A / 22.5 A / 100 A

Magnetic circuit breaker tripping

B2 / B4 / B6 / B10 / C2 / C4 / C6

Can be connected in parallel/series

Yes / yes

Max. power dissipation (no load/nominal load)

24 W / 70 W

Efficiency

> 93 % (at 400 V AC and nominal values)

Residual ripple

< 50 mV

PP

Signaling

Signaling DC OK

LED, active switching output, relay contact

Boost signaling

LED, active switching output

General data

Weight / Dimensions W x H x D

2.5 kg / 96 x 130 x 179 mm

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 18

 

-

 

10

Output connection data (solid/stranded/AWG)

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 8

 

-

 

6

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 18

 

-

 

10

Degree of protection / Protection class

IP20 / I

MTBF (IEC 61709, SN 29500)

> 509000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

Standards/regulations

Insulation voltage input/output

2 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

Safe isolation

DIN VDE 0100-410

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1 

(3-wire + PE, star net) , UL ANSI/ISA-12.12.01 Class I, Division 2, 

Groups A, B, C, D (Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

QUINT-PS/3AC/48DC/20

2320827

1

214

PHOENIX CONTACT

H

W

D

QUINT POWER, 3 AC, 48 V DC

– High system availability even in the event 

of a permanent phase failure

– High surge strength of up to 6 kV thanks 

to integrated gas-filled surge arresters

– Fast tripping of standard miniature circuit 

breakers with SFB (Selective Fuse 
Breaking) Technology dynamic power 
reserve with up to 6 times the nominal 
current for 12 ms

– Reliable starting of heavy loads with the 

static Power Boost power reserve with 
up to 1.5 times the nominal current

– Preventive function monitoring
– Flexible thanks to input voltage ranges for 

AC and DC voltages

– Adjustable output voltage of 30 to 

56 V DC

QUINT POWER power supplies – 
maximum functionality

Power supplies and UPS

Power supplies

Power supply,

3 AC, 48 V DC, 20 A

phoenixcontact-protection-html.html
background image

DC

O

K

IN

I<I

N

13 

DC

 

O

K

14 

DC

 

O

K

+

+

-

-

-

L2

L1

+

-

PE

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

Technical data

Technical data

Input data

Nominal input voltage range

2x 400 V AC ... 500 V AC

600 V DC

600 V DC

Input voltage range

2x 360 V AC ... 575 V AC

450 V DC ... 840 V DC

450 V DC ... 840 V DC

Frequency range

45 Hz ... 65 Hz / 0 Hz

- / 0 Hz

Current consumption (nominal load)

2.5 A (400 V AC)

 

/

 

2.1 A (500 V

 

AC)

0.9 A (600 V

 

DC)

0.9 A (600 V

 

DC)

Inrush current limitation at 25°C / I

2

t

<

 

85 A

 

/

 

<

 

1.5 A

2

s

<

 

26 A

 

/

 

0.8 A

2

s

Mains buffering (I

N

, typ.)

> 20 ms (400 V AC)

> 15 ms (600 V

 

DC)

Output data

Nominal output voltage

24 V DC ±1

 

%

24 V DC  ±1

 

%

Setting range of the output voltage (U

Set

)

18 V DC ... 29.5 V DC (U

IN

 

 360 V AC / 480 V DC)

18 V DC ... 26 V DC (< 480 V DC)

22.5 V DC ... 29.5 V DC (U

IN

 > 475 V DC)

22.5 V DC ... 28 V DC (U

IN

 

 475 V DC)

Output current / Power

 

Boost / SFB (20 ms)

20 A / 26 A / 120 A

20 A / - / -

Magnetic circuit breaker tripping

C6 / B16

-

Max. power dissipation (no load/nominal load)

11 W / 51 W

3.8 W / 45 W

Efficiency

> 92 % (600 V

 

DC)

 

/

 

> 90.5 % (400 V AC)

> 91 % (With 600 V DC and nominal values)

Residual ripple

< 50 mV

PP

< 40 mV

PP

Signaling

Signaling DC OK

LED, relay contact

LED

Boost signaling

LED, active switching output

-

Signaling DC

IN

 OK

LED, active switching output

-

General data

Weight / Dimensions W x H x D

2 kg / 120 x 130 x 125 mm

2 kg / 115 x 130 x 152.5 mm

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Can be aligned: Horizontally 0 mm, vertically 50 mm

Connection method

Screw connection

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 24

 

-

 

10

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

Output connection data (solid/stranded/AWG)

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 12

 

-

 

10

0.5

 

-

 

6

 

mm² / 0.5

 

-

 

4

 

mm² / 12

 

-

 

10

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 24

 

-

 

10

- / - / -

Degree of protection / Protection class

IP20 / I

IP20 / I

MTBF (IEC 61709, SN 29500)

> 860000 h (40°C)

> 701000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

Standards/regulations

Insulation voltage input/output

2 kV AC (routine test) / 1.5 kV AC (type test)

2 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950-1

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

QUINT-PS/2AC/1DC/24DC/20

2320830

1

TRIO-PS/600DC/24DC/20

2866530

1

215

PHOENIX CONTACT

QUINT POWER and TRIO POWER 
for frequency inverters

– In the event of mains failure, the DC 

intermediate circuit voltage of the 
inverter continues to supply all connected 
24 V loads without interruption

– Maintenance-free buffer solution: 

controlled machine stop in the event of 
mains failure by using the existing capacity 
in the frequency inverter or by using the 
kinetic energy of motors

QUINT POWER

– Combined solution with a 

QUINT POWER power supply

TRIO POWER

– Standard solution with two TRIO 

POWER power supplies

H

W

D

H

W

D

Power supplies for frequency inverters

Power supplies and UPS

Power supplies

Power supply with two separate input circuits 

for frequency inverters

2 AC, 1 DC/24 V DC, 20 A

Power supply,

600 V DC, 24 V DC, 20 A

phoenixcontact-protection-html.html
background image

13

I < I

N

DC

 

O

K

14

L (+)

N (-)

a

ctive

PF

C

 

 

 

 DNV GL 

 

Ex: 

 

 

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

Input voltage range

85 V AC ... 264 V AC

90 V DC ... 410 V DC +5

 

%

Frequency range

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

1.2 A (120 V AC) / 0.6 A (230 V AC)

2.2 A (120 V AC) / 1.3 A (230 V AC)

4.5 A (120 V AC) / 2.5 

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

<

 

1 A

2

s

Mains buffering (I

N

, typ.)

> 25 ms (120 V AC)

 

/

 

> 25 ms (230 V AC)

> 36 ms (120 V AC)

Output data

Nominal output voltage

24 V DC ±1

 

%

Setting range of the output voltage (U

Set

)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

Output current / Power

 

Boost / SFB (12 ms)

5 A / 7.5 A / 30 A

Magnetic circuit breaker tripping

B2 / B4 / C2

Can be connected in parallel/series

Yes / yes

Max. power dissipation (no load/nominal load)

< 3 W / < 15 W

Efficiency

> 90 % (for 230 V AC and nominal values)

> 92.5 % (for 230 V AC and nominal values)

> 93 % (for 230 V AC and nominal va

Residual ripple

< 40 mV

PP

Signaling

Signaling DC OK

LED, active switching output, relay contact

LED, active switching output, relay contact

LED, active switching outp

Boost signaling

LED, active switching output

LED, active switching 

General data

Weight / Dimensions W x H x D

0.7 kg / 40 x 130 x 125 mm

1.1 kg / 60 x 130 x 125 mm

1.7 kg / 90 x 130 x 125 mm

1.5 kg / 69 x 130 x 

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Plug-in screw connection

Plug-in screw connection

Screw connection

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 20

 

-

 

12

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 20

 

-

 

12

0.2

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 20

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / I

MTBF (IEC 61709, SN 29500)

> 635000 h (40°C)

Ambient temperature (operation)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-40 °C ...

Standards/regulations

Insulation voltage input/output

2 kV AC (routine test) / 4 kV AC (type test)

2 kV AC (routine test) / 4 kV AC (type test)

2 kV AC 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VD

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

Rail applications

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

QUINT-PS/1AC/24DC/ 5/CO

2320908

1

216

PHOENIX CONTACT

Power supplies for extreme 
requirements

QUINT POWER with protective 
coating

The protective coating protects against 

extreme ambient conditions, such as dust, 
pollution, corrosive gases, and 100% 
humidity.
– Devices with ATEX approval conform to 

standard EN 60079-15 and EN 60079-0 
and may be installed in a potentially 
explosive area (Zone 2)

– They are suitable for use in Class I, 

Division 2, Groups A, B, C, D

– Conformance with railway standard 

EN 50155

– OVP (overvoltage protection) limits surge 

voltages to 32 V

– Wide temperature range from -40°C to 

+70°C

– Fast tripping of standard miniature circuit 

breakers with SFB (Selective Fuse 
Breaking) Technology dynamic power 
reserve with up to 6 times the nominal 
current for 12 ms

– Reliable starting of heavy loads with the 

static Power Boost power reserve with 
up to 1.5 times the nominal current

– Preventive function monitoring
– Flexible thanks to input voltage ranges for 

AC and DC voltages

Power supplies and UPS

Power supplies

Power supply,

with protective coating,

1 AC, 24 V DC, 5 A

phoenixcontact-protection-html.html
background image

13

I < I

N

DC

 

O

K

14

L (+)

N (-)

a

ctive

PF

C

13

I < I

N

DC

 

O

K

14

L (+)

N (-)

a

ctive

PF

C

L1 (+)

L2

L3 (-)

13

I < I

N

DC O

K

14

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 DNV GL 

 

 

 

 

Ex: 

 

 

 

 

 

 DNV GL 

 

Ex: 

 

 

 

 

 

 DNV GL 

 

Ex: 

Technical data

Technical data

Technical data

100 V AC ... 240 V AC

110 V DC ... 250 V DC

100 V AC ... 240 V AC

110 V DC ... 250 V DC

3x 400 V AC ... 500 V AC

85 V AC ... 264 V AC

90 V DC ... 410 V DC +5

 

%

85 V AC ... 264 V AC

90 V DC ... 410 V DC +5

 

%

3x 320 V AC ... 575 V AC

2x 360 V AC ... 575 V AC

450 V DC ... 800 V DC

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

1.2 A (120 V AC) / 0.6 A (230 V AC)

2.2 A (120 V AC) / 1.3 A (230 V AC)

4.5 A (120 V AC) / 2.5 A (230 V AC)

3x 1.6 A (400 V AC) / 3x 1.3 A (500 V

 

AC)

<

 

15 A

 

/

 

<

 

1.5 A

2

s

<

 

20 A

 

/

 

<

 

3.2 A

2

s

<

 

20 A

 

/

 

<

 

3.2 A

2

s

> 25 ms (230 V AC)

> 36 ms (120 V AC)

 

/

 

> 36 ms (230 V AC)

> 32 ms (120 V AC)

 

/

 

> 32 ms (230 V AC)

> 28 ms (400 V AC)

 

/

 

> 43 ms (500 V

 

AC)

24 V DC ±1

 

%

24  V  DC  ±1

 

%

24  V  DC  ±1

 

%

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

10 A / 15 A / 60 A

20 A / 26 A / 120 A

20 A / 26 A / 120 A

B2 / B4 / B6 / C2 / C4

B2 / B4 / B6 / B10 / B16 / C2 / C4 / C6

B2 / B4 / B6 / B10 / B16 / C2 / C4 / C6

Yes / yes

Yes / yes

Yes / yes

9.1 W / 22 W

8 W / 40 W

11 W / 40 W

Efficiency

> 90 % (for 230 V AC and nominal values)

> 92.5 % (for 230 V AC and nominal values)

> 93 % (for 230 V AC and nominal values)

> 93 % (at 400 V AC and nominal values)

< 50 mV

PP

< 30 mV

PP

< 40 mV

PP

Signaling DC OK

LED, active switching output, relay contact

LED, active switching output, relay contact

LED, active switching output, relay contact

LED, active switching output, relay contact

Boost signaling

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

Weight / Dimensions W x H x D

0.7 kg / 40 x 130 x 125 mm

1.1 kg / 60 x 130 x 125 mm

1.7 kg / 90 x 130 x 125 mm

1.5 kg / 69 x 130 x 125 mm

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Plug-in screw connection

Plug-in screw connection

Screw connection

Screw connection

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 18

 

-

 

10

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 18

 

-

 

10

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 12

 

-

 

10

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 12

 

-

 

10

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 18

 

-

 

10

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 18

 

-

 

10

IP20 / I

IP20 / I

IP20 / I

> 535000 h (40°C)

> 520000 h (40°C)

> 534000 h (40°C)

Ambient temperature (operation)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

ype test)

2 kV AC (routine test) / 4 kV AC (type test)

2 kV AC (routine test) / 4 kV AC (type test)

2 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

Rail applications

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950-1 

(3-wire + PE, star net) , UL ANSI/ISA-12.12.01 Class I, Division 2, 

Groups A, B, C, D (Hazardous Location)

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

QUINT-PS/1AC/24DC/10/CO

2320911

1

QUINT-PS/1AC/24DC/20/CO

2320898

1

QUINT-PS/3AC/24DC/20/CO

2320924

1

217

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

Power supply,

with protective coating,

1 AC, 24 V DC, 10 A

Power supply,

with protective coating,

1 AC, 24 V DC, 20 A

Power supply,

with protective coating,

3 AC, 24 V DC, 20 A

phoenixcontact-protection-html.html
background image

13

14

L

/

+

N

/

-

+
+

-
-
-

 

 

 

 DNV GL 

Ex: 

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC -15 % ... +10 %

110 V DC ... 250 V DC

Input voltage range

85 V AC ... 264 V AC

99 V DC ... 275 V DC

Frequency range

50 Hz ... 60 Hz

Current consumption (nominal load)

1.4 A (100 V AC)

 

/

 

0.7 A (240 V AC)

0.8 A (110 V DC)

 

/

 

0.3 A (250 V DC)

Inrush current limitation at 25°C / I

2

t

≤ 

15 A

 

/

 

<

 

0.26 A

2

s

Mains buffering (I

N

, typ.)

> 10 ms (120 V AC)

 

/

 

> 20 ms (230 V AC)

> 20 ms (120 V AC)

Output data

Nominal output voltage

24 V DC ±1

 

%

Setting range of the output voltage (U

Set

)

24 V DC ... 28 V DC (> 24 V

 

DC, constant capacity restricted)

24 V DC ... 28 V DC (> 24 V

Output current / Dynamic Boost (5

 

s)

3 A / -

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy modul

Max. power dissipation (no load/nominal load)

< 1 W / < 10 W

Efficiency

> 89 % (for 230 V AC and nominal values)

> 90 % (for 230 V AC and nominal values)

> 89 % (for 230 V AC and nominal valu

Residual ripple

 50 mV

PP

Signaling

Signaling DC OK

LED, floating signal contact

LED, floating signal contact

LED, floating signal contact

General data

Weight / Dimensions W x H x D

0.35 kg / 30 x 130 x 115 mm

0.45 kg / 35 x 130 x 115 mm

0.45 kg / 35 x 130 x 115 mm

Assembly instructions

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Connection method

Push-in connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / II

MTBF (IEC 61709, SN 29500)

2000000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

Safe isolation

DIN VDE 0100-410

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1 , 

NEC Class 2 as per UL 1310

Limitation of harmonic line currents

EN 61000-3-2

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

TRIO-PS-2G/1AC/24DC/3/C2LPS

2903147

1

218

PHOENIX CONTACT

TRIO POWER power supplies – 
robust standard functionality

TRIO POWER 1 AC, 24 V DC

– High operational reliability thanks to the 

robust design

– Wide temperature range from -25°C to 

+70°C as well as device startup at -40°C 
(type-tested)

– Reliable starting of dynamic loads with 

the dynamic boost, which supplies up to 
1.5 times the nominal current for 5 
seconds

– Time savings during installation, thanks to 

the use of tool-free Push-in connection 
technology

– Space savings in the control cabinet 

thanks to the narrow design

– Active function monitoring with DC OK 

LED and relay contact

– Input voltage range for DC voltage of 

110 ... 250 V DC

– Third negative terminal block for 

grounding on the secondary side

– Maximum availability thanks to high MTBF 

(mean time between failure)

– Compensation of voltage drops by means 

of output voltage that can be set on the 
front

TRIO POWER, NEC Class 2

Output power limited to 100 W

– Specifically for applications that require 

certification according to 
UL 1310/508 Listed Class 2

TRIO POWER, Bridge and Deck

Optimized for use on the ship's bridge

Power supplies and UPS

Power supplies

H

W

D

Power supply,

1 AC, 24 V DC, 3 A

NEC Class 2

phoenixcontact-protection-html.html
background image

13

14

L

/

+

N

/

-

+
+

-
-
-

13

14

L

/

+

N

/

-

+
+

-
-
-

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 DNV GL 

Technical data

Technical data

100 V AC ... 240 V AC -15 % ... +10 %

110 V DC ... 250 V DC

100 V AC ... 240 V AC -15 % ... +10 %

110 V DC ... 250 V DC

85 V AC ... 264 V AC

99 V DC ... 275 V DC

85 V AC ... 264 V AC

99 V DC ... 275 V DC

50 Hz ... 60 Hz

50 Hz ... 60 Hz

2.2 A (100 V AC)

 

/

 

1.1 A (240 V AC)

1.4 A (110 V DC)

 

/

 

0.6 A (250 V DC)

2.2 A (100 V AC)

 

/

 

1.1 A (240 V AC)

1.4 A (110 V DC)

 

/

 

0.6 A (250 V DC)

≤ 

16 A

 

/

 

<

 

0.6 A

2

s

≤ 

16 A

 

/

 

<

 

0.6 A

2

s

> 20 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 100 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 100 ms (230 V AC)

24 V DC ±1

 

%

24  V  DC  ±1

 

%

DC, constant capacity restricted)

24 V DC ... 28 V DC (> 24 V

 

DC, constant capacity restricted)

24 V DC ... 28 V DC (> 24 V

 

DC, constant capacity restricted)

5 A / 7.5 A

5 A / 7.5 A

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy module / yes

< 1 W / < 16 W

< 1 W / < 16 W

Efficiency

> 89 % (for 230 V AC and nominal values)

> 90 % (for 230 V AC and nominal values)

> 89 % (for 230 V AC and nominal values)

 50 mV

PP

 50 mV

PP

Signaling DC OK

LED, floating signal contact

LED, floating signal contact

LED, floating signal contact

Weight / Dimensions W x H x D

0.35 kg / 30 x 130 x 115 mm

0.45 kg / 35 x 130 x 115 mm

0.45 kg / 35 x 130 x 115 mm

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Push-in connection

Push-in connection

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / II

IP20 / II

1970000

 h (40°C)

1970000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

 (type test)

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 kV AC (routine test) / 3 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TRIO-PS-2G/1AC/24DC/5

2903148

1

TRIO-PS-2G/1AC/24DC/5/B+D

2903144

1

219

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

H

W

D

new

Power supply,

1 AC, 24 V DC, 5 A

Power supply, Bridge and Deck

1 AC, 24 V DC, 5 A

phoenixcontact-protection-html.html
background image

14

13

a

ctive

PF

C

L

/

+

N

/

-

13

14

+
+

-
-
-

 

 

 

Ex: 

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC -15 % ... +10 %

110 V DC ... 250 V DC

Input voltage range

85 V AC ... 264 V AC

99 V DC ... 275 V DC

Frequency range

50 Hz ... 60 Hz

Current consumption (nominal load)

3.1 A (100 V AC) / 1.4 A (240 V AC)

3.1 A (100 V AC) / 1.4 A (240 V AC)

5.6 A (100 V AC) / 2.4 

Inrush current limitation at 25°C / I

2

t

≤ 

25 A

 

/

 

<

 

0.5 A

2

s

Mains buffering (I

N

, typ.)

> 15 ms (120 V AC)

 

/

 

> 15 ms (230 V AC)

> 15 ms (120 V AC)

Output data

Nominal output voltage

24 V DC ±1

 

%

Setting range of the output voltage (U

Set

)

24 V DC ... 28 V DC (> 24 V

 

DC, constant capacity restricted)

24 V DC ... 28 V DC (> 24 V

Output current / Dynamic Boost (5

 

s)

10 A / 15 A

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy modul

Max. power dissipation (no load/nominal load)

< 5.1 W (230 V) / < 25 W

< 5.1 W / < 25 W

< 5.7 W / < 44 W

Efficiency

> 91 % (for 230 V AC and nominal values)

> 91 % (for 230 V AC and nominal values)

> 93 % (for 230 V AC and nominal valu

Residual ripple

 10 mV

PP

Signaling

Signaling DC OK

LED, floating signal contact

LED, floating signal contact

LED, floating signal contact

General data

Weight / Dimensions W x H x D

1 kg / 42 x 130 x 160 mm

1 kg / 42 x 130 x 160 mm

1.5 kg / 68 x 130 x 160 mm

Assembly instructions

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Connection method

Push-in connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / I

MTBF (IEC 61709, SN 29500)

1000000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

Safe isolation

DIN VDE 0100-410

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

UL Li

Limitation of harmonic line currents

EN 61000-3-2

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

TRIO-PS-2G/1AC/24DC/10

2903149

1

220

PHOENIX CONTACT

TRIO POWER power supplies – 
robust standard functionality

TRIO POWER 1 AC, 24 V DC

– High operational reliability thanks to the 

robust design

– Wide temperature range from -25°C to 

+70°C as well as device startup at -40°C 
(type-tested)

– Reliable starting of dynamic loads with 

the dynamic boost, which supplies up to 
1.5 times the nominal current for 5 
seconds

– Time savings during installation, thanks to 

the use of tool-free Push-in connection 
technology

– Space savings in the control cabinet 

thanks to the narrow design

– Active function monitoring with DC OK 

LED and relay contact

– Input voltage range for DC voltage of 

110 ... 250 V DC

– Third negative terminal block for 

grounding on the secondary side

– Maximum availability thanks to high MTBF 

(mean time between failure)

– Compensation of voltage drops by means 

of output voltage that can be set on the 
front

TRIO POWER, NEC Class 2

Output power limited to 100 W

– Specifically for applications that require 

certification according to 
UL 1310/508 Listed Class 2

TRIO POWER, Bridge and Deck

Optimized for use on the ship's bridge

Power supplies and UPS

Power supplies

H

W

D

Power supply,

1 AC, 24 V DC, 10 A

phoenixcontact-protection-html.html
background image

14

13

a

ctive

PF

C

L

/

+

N

/

-

13

14

+
+

-
-
-

14

13

a

ctive

PF

C

L

/

+

N

/

-

13

14

+
+

-
-
-

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

Technical data

Technical data

100 V AC ... 240 V AC -15 % ... +10 %

110 V DC ... 250 V DC

100 V AC ... 240 V AC -15 % ... +10 %

110 V DC ... 250 V DC

85 V AC ... 264 V AC

99 V DC ... 275 V DC

85 V AC ... 264 V AC

99 V DC ... 275 V DC

50 Hz ... 60 Hz

50 Hz ... 60 Hz

Current consumption (nominal load)

3.1 A (100 V AC) / 1.4 A (240 V AC)

3.1 A (100 V AC) / 1.4 A (240 V AC)

5.6 A (100 V AC) / 2.4 A (240 V AC)

≤ 

25 A

 

/

 

<

 

0.5 A

2

s

≤ 

20 A

 

/

 

<

 

0.9 A

2

s

> 15 ms (230 V AC)

> 15 ms (120 V AC)

 

/

 

> 15 ms (230 V AC)

> 10 ms (120 V AC)

 

/

 

> 15 ms (230 V AC)

24 V DC ±1

 

%

24  V  DC  ±1

 

%

DC, constant capacity restricted)

24 V DC ... 28 V DC (> 24 V

 

DC, constant capacity restricted)

24 V DC ... 28 V DC (> 24 V

 

DC, constant capacity restricted)

10 A / 15 A

20 A / 30 A

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy module / yes

W (230 V) / < 25 W

< 5.1 W / < 25 W

< 5.7 W / < 44 W

Efficiency

> 91 % (for 230 V AC and nominal values)

> 91 % (for 230 V AC and nominal values)

> 93 % (for 230 V AC and nominal values)

 10 mV

PP

 30 mV

PP

Signaling DC OK

LED, floating signal contact

LED, floating signal contact

LED, floating signal contact

Weight / Dimensions W x H x D

1 kg / 42 x 130 x 160 mm

1 kg / 42 x 130 x 160 mm

1.5 kg / 68 x 130 x 160 mm

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Push-in connection

Push-in connection

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

10

 

mm² / 0.2

 

-

 

6

 

mm² / 24

 

-

 

8

IP20 / I

IP20 / I

1000000

 h (40°C)

1000000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

 (type test)

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 kV AC (routine test) / 3 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TRIO-PS-2G/1AC/24DC/10/B+D

2903145

1

TRIO-PS-2G/1AC/24DC/20

2903151

1

221

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

new

H

W

D

Power supply, Bridge and Deck

1 AC, 24

 

V

 

DC, 10

 

A

Power supply,

1 AC, 24 V DC, 20 A

phoenixcontact-protection-html.html
background image

L1

L2

L3

13

14

+
+

-
-
-

 

 

 

 DNV GL 

Ex: 

Technical data

Input data

Nominal input voltage range

3x 400 V AC ... 500 V AC -20 % ... +15 %

2x 400 V AC ... 500 V AC -10 % ... +15 %

Input voltage range

3x 320 V AC ... 575 V AC

2x 360 V AC ... 575 V AC

Frequency range

50 Hz ... 60 Hz

Current consumption (nominal load)

3x 0.4 A (400 V AC)

 

/

 

3x 0.3 A (500 V

 

AC)

2x 0.6 A (400 V AC)

 

/

 

2x 0.5 A (500 V

 

AC)

Inrush current limitation at 25°C / I

2

t

≤ 

22 A

 

/

 ≤ 

0.25 A

2

s

Mains buffering (I

N

, typ.)

> 20 ms (400 V AC)

 

/

 

> 20 ms (500 V

 

AC)

> 10 ms (400 V AC)

Output data

Nominal output voltage

24 V DC ±1

 

%

Setting range of the output voltage (U

Set

)

24 V DC ... 28 V DC (> 24 V

 

DC, constant capacity restricted)

24 V DC ... 28 V DC (> 24 V

Output current / Dynamic Boost (5

 

s)

5 A / 7.5 A

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy modul

Max. power dissipation (no load/nominal load)

< 1 W / < 12 W

Efficiency

> 91 % (at 400 V AC and nominal values)

> 92 % (at 400 V AC and nominal values)

> 93 % (at 400 V AC and nominal values)

Residual ripple

 20 mV

PP

Signaling

Signaling DC OK

LED, floating signal contact

LED, floating signal contact

LED, floating signal contact

LED, floating signal contact

General data

Weight / Dimensions W x H x D

0.4 kg / 35 x 130 x 115 mm

0.9 kg / 42 x 130 x 160 mm

1.5 kg / 65 x 130 x 160 mm

2.6 kg / 110 x 130 x

Assembly instructions

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Connection method

Push-in connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / II

MTBF (IEC 61709, SN 29500)

1300000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VD

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

UL Li

Limitation of harmonic line currents

EN 61000-3-2

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

TRIO-PS-2G/3AC/24DC/5

2903153

1

222

PHOENIX CONTACT

TRIO POWER power supplies – 
robust standard functionality

TRIO POWER 3 AC, 24 V DC

– High operational reliability thanks to the 

robust design

– Wide temperature range from -25°C to 

+70°C as well as device startup at -40°C 
(type-tested)

– Reliable starting of dynamic loads with 

the dynamic boost, which supplies up to 
1.5 times the nominal current for 5 
seconds

– Time savings during installation, thanks to 

the use of tool-free Push-in connection 
technology

– Space savings in the control cabinet 

thanks to the narrow design

– Active function monitoring with DC OK 

LED and relay contact

– Third negative terminal block for 

grounding on the secondary side

– Maximum availability thanks to high MTBF 

(mean time between failure)

– Compensation of voltage drops by means 

of output voltage that can be set on the 
front

Power supplies and UPS

Power supplies

H

W

D

Power supply,

3 AC, 24 V DC, 5 A

phoenixcontact-protection-html.html
background image

L1

L2

L3

13

14

+
+

-
-
-

L1

L2

L3

13

14

+
+

-
-
-

L1

L2

L3

13

14

+
+

-
-
-

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

Ex: 

 

 

 

Ex: 

 

 

 

Technical data

Technical data

Technical data

3x 400 V AC ... 500 V AC -20 % ... +15 %

2x 400 V AC ... 500 V AC -10 % ... +15 %

3x 400 V AC ... 500 V AC -20 % ... +15 %

2x 400 V AC ... 500 V AC -10 % ... +15 %

3x 400 V AC ... 500 V AC

3x 320 V AC ... 575 V AC

2x 360 V AC ... 575 V AC

3x 320 V AC ... 575 V AC

2x 360 V AC ... 575 V AC

3x 320 V AC ... 575 V AC

50 Hz ... 60 Hz

50 Hz ... 60 Hz

50 Hz ... 60 Hz

3x 0.6 A (400 V AC)

 

/

 

3x 0.6 A (500 V

 

AC)

2x 1.1 A (400 V AC)

 

/

 

2x 1.1 A (500 V

 

AC)

3x 1.2 A (400 V AC)

 

/

 

3x 1 A (500 V

 

AC)

2x 2.3 A (400 V AC)

 

/

 

2x 1.9 A (500 V

 

AC)

3x 2 A (400 V AC)

 

/

 

3x 1.6 A (500 V

 

AC)

3x 1.65 A (480 V AC)

≤ 

26 A

 

/

 

0.3 A

2

s

≤ 

22 A

 

/

 

0.5 A

2

s

≤ 

30 A

 

/

 

1.1 A

2

s

AC)

> 10 ms (400 V AC)

 

/

 

> 20 ms (500 V

 

AC)

> 10 ms (400 V AC)

 

/

 

> 20 ms (500 V

 

AC)

> 10 ms (400 V AC)

 

/

 

> 20 ms (500 V

 

AC)

24 V DC ±1

 

%

24  V  DC  ±1

 

%

24  V  DC  ±1

 

%

DC, constant capacity restricted)

24 V DC ... 28 V DC (> 24 V

 

DC, constant capacity restricted)

24 V DC ... 28 V DC (> 24 V

 

DC, constant capacity restricted)

24 V DC ... 28 V DC (> 24 V

 

DC, constant capacity restricted)

10 A / 15 A

20 A / 30 A

40 A / 60 A

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy module / yes

< 1.1 W / < 22 W

< 1.2 W / < 38 W

< 14 W / < 68 W

Efficiency

> 91 % (at 400 V AC and nominal values)

> 92 % (at 400 V AC and nominal values)

> 93 % (at 400 V AC and nominal values)

> 93 % (at 400 V AC and nominal values)

 20 mV

PP

 20 mV

PP

 50 mV

PP

Signaling DC OK

LED, floating signal contact

LED, floating signal contact

LED, floating signal contact

LED, floating signal contact

Weight / Dimensions W x H x D

0.4 kg / 35 x 130 x 115 mm

0.9 kg / 42 x 130 x 160 mm

1.5 kg / 65 x 130 x 160 mm

2.6 kg / 110 x 130 x 160 mm

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Push-in connection

Push-in connection

Push-in connection

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

10

 

mm² / 0.2

 

-

 

6

 

mm² / 24

 

-

 

8

0.75

 

-

 

16

 

mm² / 0.75

 

-

 

10

 

mm² / 20

 

-

 

4

IP20 / I

IP20 / I

IP20 / I

1200000

 h (40°C)

1100000

 h (40°C)

1051000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

 (type test)

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 kV AC (routine test) / 3 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TRIO-PS-2G/3AC/24DC/10

2903154

1

TRIO-PS-2G/3AC/24DC/20

2903155

1

TRIO-PS-2G/3AC/24DC/40

2903156

1

223

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

H

W

D

H

W

D

new

Power supply,

3 AC, 24 V DC, 10 A

Power supply,

3 AC, 24 V DC, 20 A

Power supply,

3 AC, 24 V DC, 40 A

phoenixcontact-protection-html.html
background image

13

14

L

/

+

N

/

-

+
+

-
-
-

 

 

 

 

Ex: 

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC -15 % ... +10 %

110 V DC ... 250 V DC

Input voltage range

85 V AC ... 264 V AC

99 V DC ... 275 V DC

Frequency range

50 Hz ... 60 Hz

Current consumption (nominal load)

1.1 A (100 V AC)

 

/

 

0.6 A (240 V AC)

0.7 A (110 V DC)

 

/

 

0.3 A (250 V DC)

Inrush current limitation at 25°C / I

2

t

≤ 

25 A

 

/

 ≤ 

0.6 A

2

s

Mains buffering (I

N

, typ.)

> 20 ms (120 V AC)

 

/

 

> 110 ms (230 V AC)

> 20 ms (120 V AC)

Output data

Nominal output voltage

12 V DC ±1

 

%

Setting range of the output voltage (U

Set

)

12 V DC ... 18 V DC (> 12 V

 

DC, constant capacity restricted)

12 V DC ... 18 V DC (> 12 V

Output current / Dynamic Boost (5

 

s)

5 A / -

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy modul

Max. power dissipation (no load/nominal load)

< 1 W (230 V) / < 10 W (230 V)

< 1 W (230 V) / < 15 W (230 V)

< 3.5 W (230 V) / < 20

Efficiency

> 86 % (for 230 V AC and nominal values)

> 89 % (for 230 V AC and nominal values)

> 92.4 % (for 230 V AC and nominal va

Residual ripple

 50 mV

PP

Signaling

Signaling DC OK

LED, floating signal contact

LED, floating signal contact

LED, floating signal contact

LED, floating signal contact

General data

Weight / Dimensions W x H x D

0.32 kg / 30 x 130 x 115 mm

0.4 kg / 35 x 130 x 115 mm

0.9 kg / 42 x 130 x 160 mm

1.4 kg / 68 x 130 x

Assembly instructions

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Connection method

Push-in connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / II

MTBF (IEC 61709, SN 29500)

2900000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VD

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1 , 

NEC Class 2 as per UL 1310

Limitation of harmonic line currents

EN 61000-3-2

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

TRIO-PS-2G/1AC/12DC/5/C2LPS

2903157

1

224

PHOENIX CONTACT

TRIO POWER power supplies – 
robust standard functionality

TRIO POWER 1 AC, 12 and 48 V DC

– High operational reliability thanks to the 

robust design

– Wide temperature range from -25°C to 

+70°C as well as device startup at -40°C 
(type-tested)

– Reliable starting of dynamic loads with 

the dynamic boost, which supplies up to 
1.5 times the nominal current for 5 
seconds

– Time savings during installation, thanks to 

the use of tool-free Push-in connection 
technology

– Space savings in the control cabinet 

thanks to the narrow design

– Active function monitoring with DC OK 

LED and relay contact

– Input voltage range for DC voltage of 

110 ... 250 V DC

– Third negative terminal block for 

grounding on the secondary side

– Maximum availability thanks to high MTBF 

(mean time between failure)

– Compensation of voltage drops by means 

of output voltage that can be set on the 
front

TRIO POWER, NEC Class 2

Output power limited to 100 W

– Specifically for applications that require 

certification according to 
UL 1310/508 Listed Class 2

Power supplies and UPS

Power supplies

H

W

D

new

Power supply,

1 AC, 12 V DC, 5 A

NEC Class 2

phoenixcontact-protection-html.html
background image

13

14

L

/

+

N

/

-

+
+

-
-
-

14

13

a

ctive

PF

C

L

/

+

N

/

-

13

14

+
+

-
-
-

14

13

a

ctive

PF

C

L

/

+

N

/

-

13

14

+
+

-
-
-

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

Technical data

Technical data

Technical data

100 V AC ... 240 V AC -15 % ... +10 %

110 V DC ... 250 V DC

100 V AC ... 240 V AC -15 % ... +10 %

110 V DC ... 250 V DC

100 V AC ... 240 V AC -15 % ... +10 %

110 V DC ... 250 V DC

85 V AC ... 264 V AC

99 V DC ... 275 V DC

85 V AC ... 264 V AC

99 V DC ... 275 V DC

85 V AC ... 264 V AC

99 V DC ... 275 V DC

50 Hz ... 60 Hz

50 Hz ... 60 Hz

50 Hz ... 60 Hz

2.2 A (100 V AC)

 

/

 

1.1 A (240 V AC)

1.4 A (110 V DC)

 

/

 

0.6 A (250 V DC)

2.9 A (100 V AC)

 

/

 

1.2 A (240 V AC)

2.4 A (110 V DC)

 

/

 

1 A (250 V DC)

5.6 A (100 V AC)

 

/

 

2.4 A (240 V AC)

5 A (110 V DC)

 

/

 

2.2 A (250 V DC)

≤ 

30 A

 

/

 ≤ 

1.5 A

2

s

15  A

 

/

 

0.3 A

2

s

20  A

 

/

 

0.7 A

2

s

> 110 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 20 ms (230 V AC)

> 15 ms (120 V AC)

 

/

 

> 15 ms (230 V AC)

> 10 ms (120 V AC)

 

/

 

> 15 ms (230 V AC)

12 V DC ±1

 

%

48  V  DC  ±1

 

%

48  V  DC  ±1

 

%

DC, constant capacity restricted)

12 V DC ... 18 V DC (> 12 V

 

DC, constant capacity restricted)

36 V DC ... 55 V DC (> 48

 

V

 

DC, constant capacity restricted)

36 V DC ... 55 V DC (> 48

 

V

 

DC, constant capacity restricted)

10 A / 15 A

5 A / 7.5 A

10 A / 15 A

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy module / yes

 W (230 V)

< 1 W (230 V) / < 15 W (230 V)

< 3.5 W (230 V) / < 20 W

< 5.7 W (230 V) / < 44 W

Efficiency

> 86 % (for 230 V AC and nominal values)

> 89 % (for 230 V AC and nominal values)

> 92.4 % (for 230 V AC and nominal values)

> 93 % (for 230 V AC and nominal values)

 50 mV

PP

< 50 mV

PP

< 50 mV

PP

Signaling DC OK

LED, floating signal contact

LED, floating signal contact

LED, floating signal contact

LED, floating signal contact

Weight / Dimensions W x H x D

0.32 kg / 30 x 130 x 115 mm

0.4 kg / 35 x 130 x 115 mm

0.9 kg / 42 x 130 x 160 mm

1.4 kg / 68 x 130 x 160 mm

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Can be aligned: Horizontally 0 mm (

 40 °C) 10 mm (

 70 °C), 

vertically 50 mm

Push-in connection

Push-in connection

Push-in connection

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

10

 

mm² / 0.2

 

-

 

6

 

mm² / 24

 

-

 

8

IP20 / II

IP20 / I

IP20 / I

1700000

 h (40°C)

1200000

 h (40°C)

> 800000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

 (type test)

1.5 kV AC (routine test) / 3 kV AC (type test)

1.5 kV AC / 3 kV AC

1.5 kV AC / 3 kV AC

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

UL Listed UL 508 , UL/C-UL Recognized UL 60950-1

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TRIO-PS-2G/1AC/12DC/10

2903158

1

TRIO-PS-2G/1AC/48DC/5

2903159

1

TRIO-PS-2G/1AC/48DC/10

2903160

1

225

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

new

H

W

D

new

H

W

D

new

Power supply,

1 AC, 12 V DC, 10 A

Power supply,

1 AC, 48 V DC, 5 A

Power supply,

1 AC, 48 V DC, 10 A

phoenixcontact-protection-html.html
background image

+
-

L
N

N

L

+

+


 

 

 

Ex: 

 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

100 V AC ... 240 V AC

Input voltage range

85 V AC ... 264 V AC

85 V AC ... 264 V AC

Frequency range

45 Hz ... 65 Hz

45 Hz ... 65 Hz

Current consumption (nominal load)

0.5 A (120 V AC) / 0.3 A (230 V AC)

1 A (120 V AC) / 0.6 A (230 V AC)

1.7 A (120 V AC) / 1 A (2

Inrush current limitation at 25°C / I

2

t

<

 

20 A

 

/

 

<

 

0.4 A

2

s

<

 

30 A

 

/

 

<

 

0.5 A

2

s

Mains buffering (I

N

, typ.)

> 25 ms (120 V AC)

 

/

 

> 115 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 85 ms (230 V AC)

> 20 ms (120 V AC)

Output data

Nominal output voltage

24 V DC ±1

 

%

24  V  DC  ±1

 

%

Output current

1.25 A

2.5 A

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy modul

Max. power dissipation (no load/nominal load)

< 0.3 W / < 5 W

< 0.3 W / < 7 W

Efficiency

> 88 % (for 230 V AC and nominal values)

> 90 % (for 230 V AC and nominal values)

> 90 % (for 230 V AC and nominal valu

Residual ripple

< 60 mV

PP

< 30 mV

PP

Signaling

Signaling DC OK

LED

LED

General data

Weight / Dimensions W x H x D

0.15 kg / 22.5 x 90 x 84 mm

0.2 kg / 35 x 90 x 84 mm

0.34 kg / 55 x 90 x 84 mm

0.5 kg / 37 x 130 x 12

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 m

Connection method

Screw connection

Screw connection

Connection data solid/stranded/AWG

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

Degree of protection / Protection class

IP20 / II

IP20 / II

MTBF (IEC 61709, SN 29500)

> 

1158000

 h (40°C)

> 785000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

NEC Class 2 as per UL 1310

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

NEC Class 2 as per UL 1310 , UL ANSI/ISA-12.12.01 Class I, 

Division 2, Groups A, B, C, D T4A (Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

UNO-PS/1AC/24DC/ 30W

2902991

1

UNO-PS/1AC/24DC/ 60W

2902992

1

226

PHOENIX CONTACT

UNO POWER, 1 AC, 24 V DC

– The wide range of products covers all 

common voltage levels

– Maximum energy efficiency: save energy 

thanks to high efficiency and extremely 
low idling losses

– Save space in the control cabinet thanks 

to extremely high power density

– Housing depth of 84 mm, tailored to all 

popular 120 mm control boxes

– Wide temperature range from -25°C to 

+70°C

UNO POWER power supplies – 
compact basic functionality

Power supplies and UPS

Power supplies

Power supply,

1 AC, 24 DC, 30 W

NEC Class 2

Power supply,

1 AC, 24 DC, 60 W

NEC Class 2

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

N

L

+

+


+
-

L
N

L

N

a

ctive

PF

C

PE

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

Ex: 

 

 

 

Ex: 

 

 

 

 

Ex: 

Technical data

Technical data

Technical data

100 V AC ... 240 V AC

100 V AC ... 240 V AC

100 V AC ... 240 V AC

85 V AC ... 264 V AC

85 V AC ... 264 V AC

85 V AC ... 264 V AC

45 Hz ... 65 Hz

45 Hz ... 65 Hz

45 Hz ... 65 Hz

Current consumption (nominal load)

0.5 A (120 V AC) / 0.3 A (230 V AC)

1 A (120 V AC) / 0.6 A (230 V AC)

1.7 A (120 V AC) / 1 A (230 V AC)

1.4 A (120 V AC) / 0.8 A (230 V AC)

2.3 A (120 V AC) / 1.2 A (230 V AC)

<

 

40 A

 

/

 

<

 

1.5 A

2

s

<

 

50 A

 

/

 

<

 

0.8 A

2

s

<

 

80 A

 

/

 

<

 

2 A

2

s

> 85 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 100 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 20 ms (230 V AC)

> 10 ms (120 V AC)

 

/

 

> 10 ms (230 V AC)

24 V DC ±1

 

%

24  V  DC  ±1

 

%

24 V DC  ±1

 

%

4.2 A

6.25 A

10 A

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy module / No

yes, with redundancy module / No

< 0.5 W / < 11 W

< 1.2 W / < 9.7 W

< 1.1 W / < 18.8 W

Efficiency

> 88 % (for 230 V AC and nominal values)

> 90 % (for 230 V AC and nominal values)

> 90 % (for 230 V AC and nominal values)

> 94 % (for 230 V AC and nominal values)

> 93 % (for 230 V AC and nominal values)

< 30 mV

PP

< 40 mV

PP

< 50 mV

PP

LED

LED

LED

Weight / Dimensions W x H x D

0.15 kg / 22.5 x 90 x 84 mm

0.2 kg / 35 x 90 x 84 mm

0.34 kg / 55 x 90 x 84 mm

0.5 kg / 37 x 130 x 125 mm

0.66 kg / 45 x 130 x 125 mm

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Screw connection

Screw connection

Screw connection

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

IP20 / II

IP20 / II

IP20 / I

> 738000 h (40°C)

> 868000 h (40°C)

> 562000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 55 °C derating: 2.5%/K)

ype test)

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 

(Hazardous Location)

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 

(Hazardous Location)

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 

(Hazardous Location)

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

UNO-PS/1AC/24DC/100W

2902993

1

UNO-PS/1AC/24DC/150W

2904376

1

UNO-PS/1AC/24DC/240W

2904372

1

227

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

Power supply,

1 AC, 24 DC, 100 W

Power supply,

1 AC, 24 DC, 150 W

Power supply,

1 AC, 24 DC, 240 W

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

N

L

+

+


L2

/

N

L1

/

L

+

+


 

 

Ex: 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

2x 400 V AC ... 500 V AC

100 V AC ... 240 V AC

100 V AC ... 240 V AC

100 V AC ... 

Input voltage range

85 V AC ... 264 V AC

2x 264 V AC ... 575 V AC

85 V AC ... 264 V AC

85 V AC ... 264 V AC

85 V AC ... 264 V AC

Frequency range

45 Hz ... 65 Hz

45 Hz ... 65 Hz

Current consumption (nominal load)

1.5 A (120 V AC) / 1 A (230 V AC)

0.6 A (400 V AC) / 0.5 A (500 V

 

AC)

0.5 A (120 V AC) / 0.3 A (230 V AC)

1 A (120 V AC) / 0.6 A (230 V AC)

1.7 A (120 V AC) / 1 A (230 V AC)

Inrush current limitation at 25°C / I

2

t

<

 

40 A

 

/

 

<

 

1.5 A

2

s

<

 

30 A

 

/

 

<

 

0.5 A

2

s

Mains buffering (I

N

, typ.)

> 25 ms (120 V AC)

 

/

 

> 100 ms (230 V AC)

> 65 ms (400 V AC)

 

/

 

> 100 ms (500 V

 

AC)

> 20 ms (120 V AC)

Output data

Nominal output voltage

24 V DC ±1

 

%

24  V  DC  ±1

 

%

Output current

3.75 A

3.75 A

Can be connected in parallel/series

No / No

No / No

Max. power dissipation (no load/nominal load)

< 0.5 W / < 12 W

< 0.7 W / < 12 W

Efficiency

> 88.5 % (for 230 V AC and nominal values)

> 89.5 %

Residual ripple

< 45 mV

PP

< 50 mV

PP

Signaling

Signaling DC OK

LED

LED

General data

Weight / Dimensions W x H x D

0.34 kg / 55 x 90 x 84 mm

0.32 kg / 55 x 90 x 84 mm

0.15 kg / 22.5 x 90 x 84 mm

0.2 kg / 35 x 90 x 84

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 m

Connection method

Screw connection

Screw connection

Connection data solid/stranded/AWG

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

Degree of protection / Protection class

IP20 / II

IP20 / II

MTBF (IEC 61709, SN 29500)

> 

1159000

 h (40°C)

> 828000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IE

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

NEC Class 2 as per UL 1310 , UL ANSI/ISA-12.12.01 Class I, 

Division 2, Groups A, B, C, D T4 (Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

NEC Class 2 as per UL 1310 , UL ANSI/ISA-12.12.01 Class I, 

Division 2, Groups A, B, C, D T4 (Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

UNO-PS/1AC/24DC/90W/C2LPS

2902994

1

UNO-PS/2AC/24DC/90W/C2LPS

2904371

1

228

PHOENIX CONTACT

UNO POWER, 1 AC, 12 and 24 V DC

– The wide range of products covers all 

common voltage levels

– Maximum energy efficiency: save energy 

thanks to high efficiency and extremely 
low idling losses

– Save space in the control cabinet thanks 

to extremely high power density

– Housing depth of 84 mm, tailored to all 

popular 120 mm control boxes

– Wide temperature range from -25°C to 

+70°C

UNO POWER, 2 AC, 24 V DC, 
NEC Class 2

Output power limited to 100 W

– Specifically for applications that require 

certification according to 
UL 1310/508 Listed Class 2

UNO POWER power supplies – 
compact basic functionality

Power supplies and UPS

Power supplies

Power supply,

1 AC, 24 DC, 90 W

NEC Class 2

Power supply,

2 AC, 24 DC, 90 W

NEC Class 2

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

+
-

L
N

N

L

+

+


N

L

+

+


For further information and full technical data, visit phoenixcontact.net/products

 

 

 

Ex: 

 

 

 

Ex: 

 

 

 

Ex: 

Technical data

Technical data

Technical data

Nominal input voltage range

100 V AC ... 240 V AC

2x 400 V AC ... 500 V AC

100 V AC ... 240 V AC

100 V AC ... 240 V AC

100 V AC ... 240 V AC

Input voltage range

85 V AC ... 264 V AC

2x 264 V AC ... 575 V AC

85 V AC ... 264 V AC

85 V AC ... 264 V AC

85 V AC ... 264 V AC

45 Hz ... 65 Hz

45 Hz ... 65 Hz

45 Hz ... 65 Hz

AC)

0.5 A (120 V AC) / 0.3 A (230 V AC)

1 A (120 V AC) / 0.6 A (230 V AC)

1.7 A (120 V AC) / 1 A (230 V AC)

<

 

25 A

 

/

 

<

 

0.3 A

2

s

<

 

30 A

 

/

 

<

 

0.5 A

2

s

<

 

30 A

 

/

 

<

 

1.5 A

2

s

AC)

> 20 ms (120 V AC)

 

/

 

> 110 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 90 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 85 ms (230 V AC)

12 V DC ±1

 

%

12  V  DC  ±1

 

%

12 V DC  ±1

 

%

2.5 A

4.6 A

8.3 A

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy module / yes

< 0.3 W / < 4.6 W

< 0.3 W / < 8 W

< 0.4 W / < 12 W

> 87 % (for 230 V AC and nominal values)

> 89 % (for 230 V AC and nominal values)

> 89.5 %

< 30 mV

PP

< 30 mV

PP

< 75 mV

PP

LED

LED

LED

Weight / Dimensions W x H x D

0.34 kg / 55 x 90 x 84 mm

0.32 kg / 55 x 90 x 84 mm

0.15 kg / 22.5 x 90 x 84 mm

0.2 kg / 35 x 90 x 84 mm

0.34 kg / 55 x 90 x 84 mm

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Screw connection

Screw connection

Screw connection

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

IP20 / II

IP20 / II

IP20 / II

> 953000 h (40°C)

> 865000 h (40°C)

> 500000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

ype test)

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 

(Hazardous Location)

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4A 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 

(Hazardous Location)

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

UNO-PS/1AC/12DC/ 30W

2902998

1

UNO-PS/1AC/12DC/ 55W

2902999

1

UNO-PS/1AC/12DC/100W

2902997

1

229

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

Power supply,

1 AC, 12 DC, 30 W

Power supply,

1 AC, 12 DC, 55 W

Power supply,

1 AC, 12 DC, 100 W

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

+
-

L
N

N

L

+

+


 

 

 

Ex: 

 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

100 V AC ... 240 V AC

Input voltage range

85 V AC ... 264 V AC

85 V AC ... 264 V AC

Frequency range

45 Hz ... 65 Hz

45 Hz ... 65 Hz

Current consumption (nominal load)

0.5 A (120 V AC) / 0.3 A (230 V AC)

0.7 A (120 V AC) / 0.5 A (230 V AC)

0.6 A (120 V AC) / 0.4 

Inrush current limitation at 25°C / I

2

t

<

 

30 A

 

/

 

<

 

0.5 A

2

s

<

 

30 A

 

/

 

<

 

0.5 A

2

s

Mains buffering (I

N

, typ.)

> 35 ms (120 V AC)

 

/

 

> 135 ms (230 V AC)

> 30 ms (120 V AC)

 

/

 

> 120 ms (230 V AC)

> 20 ms (120 V AC)

Output data

Nominal output voltage

5 V DC ±1

 

%

5  V  DC  ±1

 

%

Output current

5 A

8 A

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy modul

Max. power dissipation (no load/nominal load)

< 0.3 W / < 4.5 W

< 0.3 W / < 7.5 W

Efficiency

> 84 %

> 85 % (for 230 V AC and nominal values)

> 87 % (for 230 V AC and nominal values)

> 88.5 % (for 230 V AC and nomi

Residual ripple

< 40 mV

PP

< 100 mV

PP

Signaling

Signaling DC OK

LED

LED

General data

Weight / Dimensions W x H x D

0.15 kg / 22.5 x 90 x 84 mm

0.21 kg / 35 x 90 x 84 mm

0.15 kg / 22.5 x 90 x 84 mm

0.21 kg / 35 x 90 x

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 m

Connection method

Screw connection

Screw connection

Connection data solid/stranded/AWG

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

Degree of protection / Protection class

IP20 / II

IP20 / II

MTBF (IEC 61709, SN 29500)

> 

2174000

 h (40°C)

> 

1201000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IE

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4A 

(Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

UNO-PS/1AC/ 5DC/ 25W

2904374

1

UNO-PS/1AC/ 5DC/ 40W

2904375

1

230

PHOENIX CONTACT

UNO POWER, 1 AC, 5 and 15 V DC

– The wide range of products covers all 

common voltage levels

– Maximum energy efficiency: save energy 

thanks to high efficiency and extremely 
low idling losses

– Save space in the control cabinet thanks 

to extremely high power density

– Housing depth of 84 mm, tailored to all 

popular 120 mm control boxes

– Wide temperature range from -25°C to 

+70°C

UNO POWER power supplies – 
compact basic functionality

Power supplies and UPS

Power supplies

Power supply,

1 AC, 5 DC, 25 W

Power supply,

1 AC, 5 DC, 40 W

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

+
-

L
N

N

L

+

+


N

L

+

+


For further information and full technical data, visit phoenixcontact.net/products

 

 

 

Ex: 

 

 

 

Ex: 

 

 

Ex: 

Technical data

Technical data

Technical data

100 V AC ... 240 V AC

100 V AC ... 240 V AC

100 V AC ... 240 V AC

85 V AC ... 264 V AC

85 V AC ... 264 V AC

85 V AC ... 264 V AC

45 Hz ... 65 Hz

45 Hz ... 65 Hz

45 Hz ... 65 Hz

Current consumption (nominal load)

0.5 A (120 V AC) / 0.3 A (230 V AC)

0.7 A (120 V AC) / 0.5 A (230 V AC)

0.6 A (120 V AC) / 0.4 A (230 V AC)

1 A (120 V AC) / 0.6 A (230 V AC)

1.7 A (120 V AC) / 1 A (230 V AC)

<

 

30 A

 

/

 

<

 

0.3 A

2

s

<

 

25 A

 

/

 

<

 

0.5 A

2

s

<

 

30 A

 

/

 

<

 

1.5 A

2

s

> 120 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 115 ms (230 V AC)

> 25 ms (120 V AC)

 

/

 

> 90 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 85 ms (230 V AC)

15 V DC ±1

 

%

15  V  DC  ±1

 

%

15 V DC  ±1

 

%

2 A

3.7 A

6.67 A

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy module / yes

yes, with redundancy module / yes

< 0.3 W / < 4.6 W

< 0.3 W / < 7 W

< 0.4 W / < 12 W

Efficiency

> 84 %

> 85 % (for 230 V AC and nominal values)

> 87 % (for 230 V AC and nominal values)

> 88.5 % (for 230 V AC and nominal values)

> 89 % (for 230 V AC and nominal values)

< 40 mV

PP

< 50 mV

PP

< 75 mV

PP

LED

LED

LED

Weight / Dimensions W x H x D

0.15 kg / 22.5 x 90 x 84 mm

0.21 kg / 35 x 90 x 84 mm

0.15 kg / 22.5 x 90 x 84 mm

0.21 kg / 35 x 90 x 84 mm

0.34 kg / 55 x 90 x 84 mm

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Screw connection

Screw connection

Screw connection

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

IP20 / II

IP20 / II

IP20 / II

> 911000 h (40°C)

> 647000 h (40°C)

> 727000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

ype test)

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4A 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 

(Hazardous Location)

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

UNO-PS/1AC/15DC/30W

2903000

1

UNO-PS/1AC/15DC/ 55W

2903001

1

UNO-PS/1AC/15DC/100W

2903002

1

231

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

Power supply,

1 AC, 15 DC, 30 W

Power supply,

1 AC, 15 DC, 55 W

Power supply,

1 AC, 15 DC, 100 W

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

N

L

+

+


N

L

+

+


 

 

Ex: 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

100 V AC ... 240 V AC

Input voltage range

85 V AC ... 264 V AC

85 V AC ... 264 V AC

Frequency range

45 Hz ... 65 Hz

45 Hz ... 65 Hz

Current consumption (nominal load)

1 A (120 V AC) / 0.6 A (230 V AC)

1.7 A (120 V AC) / 1 A (230 V AC)

Inrush current limitation at 25°C / I

2

t

<

 

30 A

 

/

 

<

 

0.5 A

2

s

<

 

40 A

 

/

 

<

 

1.4 A

2

s

Mains buffering (I

N

, typ.)

> 20 ms (120 V AC)

 

/

 

> 90 ms (230 V AC)

> 25 ms (120 V AC)

 

/

 

> 90 ms (230 V AC)

Output data

Nominal output voltage

48 V DC ±1

 

%

48  V  DC  ±1

 

%

Output current

1.25 A

2.1 A

Can be connected in parallel/series

yes, with redundancy module / yes

yes, with redundancy module / yes

Max. power dissipation (no load/nominal load)

< 0.4 W / < 7 W

< 0.4 W / < 11 W

Efficiency

> 90 % (for 230 V AC and nominal values)

> 90 % (for 230 V AC and nominal values)

Residual ripple

< 35 mV

PP

< 40 mV

PP

Signaling

Signaling DC OK

LED

LED

General data

Weight / Dimensions W x H x D

0.21 kg / 35 x 90 x 84 mm

0.34 kg / 55 x 90 x 84 mm

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Connection method

Screw connection

Screw connection

Connection data solid/stranded/AWG

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

Degree of protection / Protection class

IP20 / II

IP20 / II

MTBF (IEC 61709, SN 29500)

1138000

 h (40°C)

1010000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

Standards/regulations

Insulation voltage input/output

3 kV AC (routine test) / 4 kV AC (type test)

3 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4A 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 

(Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

UNO-PS/1AC/48DC/ 60W

2902995

1

UNO-PS/1AC/48DC/100W

2902996

1

232

PHOENIX CONTACT

UNO POWER, 1 AC, 48 V DC

– The wide range of products covers all 

common voltage levels

– Maximum energy efficiency: save energy 

thanks to high efficiency and extremely 
low idling losses

– Save space in the control cabinet thanks 

to extremely high power density

– Housing depth of 84 mm, tailored to all 

popular 120 mm control boxes

– Wide temperature range from -25°C to 

+70°C

H

W

D

H

W

D

UNO POWER power supplies – 
compact basic functionality

Power supplies and UPS

Power supplies

Power supply,

1 AC, 48 DC, 60 W

Power supply,

1 AC, 48 DC, 100 W

phoenixcontact-protection-html.html
background image

-

+

+

+

-

-

For further information and full technical data, visit phoenixcontact.net/products

 

 

Technical data

Input data

Nominal input voltage range

350 V DC ... 900 V DC

Input voltage range

300 V DC ... 1000 V DC

Frequency range

-

Current consumption (nominal load)

0.19 A (350 V DC) / 0.07 A (1000 V DC)

Inrush current limitation at 25°C / I

2

t

<

 

1 A

 

/

 

<

 

0.38 A

2

s

Mains buffering (I

N

, typ.)

Output data

Nominal output voltage

24 V DC ±1

 

%

Output current

2.5 A

Can be connected in parallel/series

yes, with redundancy module / No

Max. power dissipation (no load/nominal load)

< 0.5 W / < 6.5 W

Efficiency

> 90 %

Residual ripple

< 20 mV

PP

Signaling

Signaling DC OK

LED

General data

Weight / Dimensions W x H x D

0.3 kg / 55 x 90 x 84 mm

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Connection method

Screw connection

Connection data solid/stranded/AWG

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

Degree of protection / Protection class

IP20 / II

MTBF (IEC 61709, SN 29500)

> 

1160000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

Standards/regulations

Insulation voltage input/output

3 kV DC (routine test) / 8 kV DC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Electrical safety

-

Electronic equipm. for electrical power installations

-

Safe isolation

DIN VDE 0100-410

UL approvals

UL 1741 , IEC 62109-1

Limitation of harmonic line currents

EN 61000-3-2

Ordering data

Description

Type

Order No.

Pcs./Pkt.

DC/DC converter,

 primary-switched

UNO-PS/350-900DC/24DC/60W

2906300

1

233

PHOENIX CONTACT

UNO POWER, input up to 1000 V

– Connect directly to the PV string: no 

need to supply an AC connection

– Robust and reliable at temperatures from 

-25°C to +70°C

– Can also be used in small control boxes, 

thanks to the compact design and high 
degree of efficiency

– Simplified startup, thanks to LED function 

monitoring

H

W

D

new

UNO POWER power supplies –
DC/DC converter

Power supplies and UPS

Power supplies

DC/DC converter,

350

 

-

 

900

 

V

 

DC, 24

 

V

 

DC, 60

 

W

phoenixcontact-protection-html.html
background image

N (-)

NC

NC

L (+)

DC OK

L

N

NC

13

24V

24V

14

0V

0V

 

 

Ex: 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

100 V AC ... 240 V AC

Input voltage range

85 V AC ... 264 V AC

90 V DC ... 350 V DC

85 V AC ... 264 V AC

Frequency range

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz

Current consumption (nominal load)

0.55 A (100 V AC) / 0.23 A (240 V AC)

0.75 A (120 V AC) / 0.45 A (230 V AC)

0.7 A (120 V AC) / 

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

0.6 A

2

s

<

 

15 A

 

/

 

0.6 A

2

s

Mains buffering (I

N

, typ.)

> 20 ms (120 V AC)

 

/

 

> 110 ms (230 V AC)

> 35 ms (120 V AC)

 

/

 

> 150 ms (230 V AC)

> 35 ms (120 V AC)

Output data

Nominal output voltage

24 V DC ±1

 

%

24  V  DC  ±1

 

%

Setting range of the output voltage (U

Set

)

22.5 V DC ... 28.5 V DC (> 24 V

 

DC, constant capacity restricted)

-

Output current / Power

 

Boost

1.3 A / 1.6 A

1.5 A / 2 A

Can be connected in parallel/series

Yes / yes

Yes / No

Max. power dissipation (no load/nominal load)

1.4 W / 4.5 W

1.5 W / 6.5 W

Efficiency

> 85 % (for 230 V AC and nominal values)

> 84 % (for 230 V AC and nominal values)

> 88 % (for 230 V AC and nominal valu

Residual ripple

< 20 mV

PP

< 40 mV

PP

Signaling

Signaling DC OK

LED, active switching output

LED, relay contact

General data

Weight / Dimensions W x H x D

0.2 kg / 22.5 x 99 x 107 mm

0.25 kg / 35 x 99 x 95 mm

0.25 kg / 45 x 99 x 107 mm

0.4 kg / 67.5 x 99 x

Assembly instructions

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can 

Connection method

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw 

Connection data solid/stranded/AWG

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / II

IP20 / II

MTBF (IEC 61709, SN 29500)

> 

1104000

 h (40°C)

> 

2789000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

3 kV (routine test) / 4 kV (type test)

3 kV (routine test) / 4 kV (type test)

3 kV (routine test) 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 609

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

MINI-PS-100-240AC/24DC/1.3

2866446

1

MINI-SYS-PS-100-240AC/24DC/1.5

2866983

1

Accessories

Accessories

DIN rail connector

 (optional), for routing through the supply 

voltage and data signal, two pieces are required per device

ME 17,5 TBUS 1,5/ 5-ST-3,81 GN

2709561

10

234

PHOENIX CONTACT

MINI POWER, 1 AC, 24 V DC

– Easy-to-maintain connection method 

thanks to coded COMBICON connector

– Remote monitoring of output voltage via 

switching output

MINI POWER, NEC Class 2

– Output power limited to 100 W: 

Specifically for applications that require 
certification according to 
UL 1310/508 Listed Class 2

MINI POWER power supplies – for 
measurement and control technology

Power supplies and UPS

Power supplies

Power supply,

1 AC, 24 V DC, 1.3 A

NEC Class 2

Power supply,

1 AC, 24 V DC, 1.5 A,

DIN rail connector optional

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

N (-)

NC

NC

L (+)

DC OK

L (+)

N (-)

DC OK

L (+)

N (-)

DC OK

For further information and full technical data, visit phoenixcontact.net/products

 

 

Ex: 

 

 

Ex: 

 

 

Ex: 

Technical data

Technical data

Technical data

100 V AC ... 240 V AC

100 V AC ... 240 V AC

100 V AC ... 240 V AC

85 V AC ... 264 V AC

90 V DC ... 350 V DC

85 V AC ... 264 V AC

90 V DC ... 350 V DC

85 V AC ... 264 V AC

90 V DC ... 350 V DC

45 Hz ... 65 Hz

45 Hz ... 65 Hz

45 Hz ... 65 Hz

Current consumption (nominal load)

0.55 A (100 V AC) / 0.23 A (240 V AC)

0.75 A (120 V AC) / 0.45 A (230 V AC)

0.7 A (120 V AC) / 0.4 A (230 V AC)

1.3 A (120 V AC) / 0.8 A (230 V AC)

1.3 A (120 V AC) / 0.8 A (230 V AC)

<

 

15 A

 

/

 

4.1 A

2

s

<

 

15 A

 

/

 

2.1 A

2

s

<

 

15 A

 

/

 

2.1 A

2

s

> 150 ms (230 V AC)

> 35 ms (120 V AC)

 

/

 

> 170 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 100 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 100 ms (230 V AC)

24 V DC ±1

 

%

24  V  DC  ±1

 

%

24 V DC  ±1

 

%

22.5 V DC ... 28.5 V DC (> 24 V

 

DC, constant capacity restricted)

22.5 V DC ... 26 V DC (> 24 V

 

DC, constant capacity restricted)

22.5 V DC ... 28.5 V DC (> 24 V

 

DC, constant capacity restricted)

2 A / 2.9 A

3.8 A / -

4 A / 5 A

Yes / yes

Yes / yes

Yes / yes

2 W / 7 W

2.5 W / 12 W

2.5 W / 12 W

Efficiency

> 85 % (for 230 V AC and nominal values)

> 84 % (for 230 V AC and nominal values)

> 88 % (for 230 V AC and nominal values)

> 88 % (for 230 V AC and nominal values)

> 88 % (for 230 V AC and nominal values)

< 20 mV

PP

< 40 mV

PP

< 20 mV

PP

LED, active switching output

LED, active switching output

LED, active switching output

Weight / Dimensions W x H x D

0.2 kg / 22.5 x 99 x 107 mm

0.25 kg / 35 x 99 x 95 mm

0.25 kg / 45 x 99 x 107 mm

0.4 kg / 67.5 x 99 x 107 mm

0.4 kg / 67.5 x 99 x 107 mm

lly 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Connection method

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / II

IP20 / II

IP20 / II

> 507000 h (40°C)

> 815000 h (40°C)

> 815000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

st)

3 kV (routine test) / 4 kV (type test)

3 kV (routine test) / 4 kV (type test)

3 kV (routine test) / 3 kV (type test)

3 kV (routine test) / 3 kV (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

MINI-PS-100-240AC/24DC/2

2938730

1

MINI-PS-100-240AC/24DC/C2LPS

2866336

1

MINI-PS-100-240AC/24DC/4

2938837

1

Accessories

Accessories

Accessories

235

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

Power supply,

1 AC, 24 V DC, 2 A

NEC Class 2

Power supply,

1 AC, 24 V DC, 100 W

NEC Class 2

Power supply,

1 AC, 24 V DC, 4 A

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

N (-)

NC

NC

L (+)

N (-)

NC

NC

L (+)

 

 

Ex: 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

100 V AC ... 240 V AC

Input voltage range

85 V AC ... 264 V AC

90 V DC ... 350 V DC

85 V AC ... 264 V AC

90 V DC ... 350 V DC

Frequency range

45 Hz ... 65 Hz

45 Hz ... 65 Hz

Current consumption (nominal load)

0.4 A (120 V AC) / 0.2 A (230 V AC)

0.4 A (120 V AC) / 0.2 A (230 V AC)

1.3 A (120 V AC) / 0.8 

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

1.5 A

2

s

<

 

15 A

 

/

 

1.7 A

2

s

Mains buffering (I

N

, typ.)

> 30 ms (120 V AC)

 

/

 

> 140 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 120 ms (230 V AC)

> 20 ms (120 V AC)

Output data

Nominal output voltage

5 V DC ±1

 

%

12  V  DC  ±1

 

%

Setting range of the output voltage (U

Set

)

4.5 V DC ... 5.5 V DC (> 5

 

V

 

DC, constant capacity restricted)

10 V DC ... 15 V DC (> 12 V

 

DC, constant capacity restricted)

10 V DC ... 15 V DC (> 12 V

Output current / Power

 

Boost

3 A / 5 A

2 A / 2.3 A

Can be connected in parallel/series

Yes / yes

Yes / yes

Max. power dissipation (no load/nominal load)

1 W / 5 W

< 1 W / < 7 W

Efficiency

> 73 % (for 230 V AC and nominal values)

> 86 % (for 230 V AC and nominal values)

> 88 % (for 230 V AC and nominal valu

Residual ripple

< 40 mV

PP

< 20 mV

PP

Signaling

Signaling DC OK

LED

LED

General data

Weight / Dimensions W x H x D

0.17 kg / 22.5 x 99 x 107 mm

0.25 kg / 45 x 99 x 107 mm

0.4 kg / 67.5 x 99 x 107 mm

0.25 kg / 45 x 99

Assembly instructions

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can 

Connection method

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw 

Connection data solid/stranded/AWG

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / II

IP20 / II

MTBF (IEC 61709, SN 29500)

> 766000 h (40°C)

> 507000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

3 kV (routine test) / 4 kV (type test)

3 kV (routine test) / 4 kV (type test)

3 kV (routine test) 

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 609

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

MINI-PS-100-240AC/ 5DC/3

2938714

1

MINI-PS-100-240AC/10-15DC/2

2938756

1

Accessories

Accessories

DIN rail connector

 (optional), for routing through the supply 

voltage and data signal, two pieces are required per device

236

PHOENIX CONTACT

MINI POWER, 1 AC, 5 to 15 V DC

– Easy-to-maintain connection method 

thanks to coded COMBICON connector

– Remote monitoring of output voltage via 

switching output

MINI POWER, ±15 V DC

– For supplying operational amplifiers

MINI POWER EX

Corresponds to standard EN 60079-15

– Installation in a potentially explosive area 

in which category 3G equipment is 
required (Zone 2).

MINI POWER power supplies – for 
measurement and control technology

Power supplies and UPS

Power supplies

Power supply,

1 AC, 5 V DC, 3 A

Power supply,

1 AC, 10 - 15 V DC, 2 A

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

L (+)

N (-)

DC OK

NC

NC

L (+)

N (-)

OV

OV

L

N

NC

13

24V

24V

14

0V

0V

For further information and full technical data, visit phoenixcontact.net/products

 

 

Ex: 

 

 

Ex: 

 

 

 

Technical data

Technical data

Technical data

100 V AC ... 240 V AC

100 V AC ... 240 V AC

100 V AC ... 240 V AC

85 V AC ... 264 V AC

90 V DC ... 350 V DC

85 V AC ... 264 V AC

90 V DC ... 350 V DC

85 V AC ... 264 V AC

45 Hz ... 65 Hz

45 Hz ... 65 Hz

45 Hz ... 65 Hz

Current consumption (nominal load)

0.4 A (120 V AC) / 0.2 A (230 V AC)

0.4 A (120 V AC) / 0.2 A (230 V AC)

1.3 A (120 V AC) / 0.8 A (230 V AC)

0.6 A (120 V AC) / 0.4 A (230 V AC)

0.75 A (120 V AC) / 0.45 A (230 V AC)

<

 

15 A

 

/

 

2.1 A

2

s

<

 

35 A

 

/

 

4 A

2

s

<

 

15 A

 

/

 

0.6 A

2

s

> 120 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 20 ms (230 V AC)

> 30 ms (120 V AC)

 

/

 

> 150 ms (230 V AC)

> 35 ms (120 V AC)

 

/

 

> 150 ms (230 V AC)

12 V DC ±1

 

%

± 15 V DC ±1

 

%

24 V DC  ±1

 

%

DC, constant capacity restricted)

10 V DC ... 15 V DC (> 12 V

 

DC, constant capacity restricted)

-

-

8 A

1 A / 1.5 A

1.5 A / 2 A

Yes / yes

Yes / yes

Yes / yes

< 2.5 W / < 12 W

2 W / 8 W

1.5 W / 6.5 W

Efficiency

> 73 % (for 230 V AC and nominal values)

> 86 % (for 230 V AC and nominal values)

> 88 % (for 230 V AC and nominal values)

> 80 % (for 230 V AC and nominal values)

> 84 % (for 230 V AC and nominal values)

< 40 mV

PP

< 30 mV

PP

< 40 mV

PP

LED, active switching output

LED

LED, relay contact

Weight / Dimensions W x H x D

0.17 kg / 22.5 x 99 x 107 mm

0.25 kg / 45 x 99 x 107 mm

0.4 kg / 67.5 x 99 x 107 mm

0.25 kg / 45 x 99 x 107 mm

0.25 kg / 35 x 99 x 95 mm

lly 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Connection method

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / II

IP20 / II

IP20 / II

> 984000 h (40°C)

> 500000 h (40°C)

> 

2789000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

st)

3 kV (routine test) / 4 kV (type test)

3 kV (routine test) / 3 kV (type test)

3 kV (routine test) / 4 kV (type test)

3 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

MINI-PS-100-240AC/10-15DC/8

2866297

1

MINI-PS-100-240AC/2X15DC/1

2938743

1

MINI-PS-100-240AC/24DC/1.5/EX

2866653

1

Accessories

Accessories

Accessories

ME 17,5 TBUS 1,5/ 5-ST-3,81 GN

2709561

10

237

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

Power supply,

1 AC, 10 - 15 V DC, 8 A

Power supply,

1 AC, ±15 V DC, 1 A

NEC Class 2

Power supply

1 AC, 24 DC, 1.5 A

DIN rail connector optional

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

+
-

L

N

(

-)

(

+)

 

 

 

Ex: 

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

Input voltage range

85 V AC ... 264 V AC

95 V DC ... 250 V DC

Frequency range

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

0.28 A (120 V AC) / 0.13 A (230 V AC)

0.3 A (120 V AC) / 0.25 A (230 V AC)

0.3 A (120 V AC) / 0

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

<

 

0.1 A

2

s

Mains buffering (I

N

, typ.)

> 15 ms (120 V AC)

 

/

 

> 90 ms (230 V AC)

> 15 ms (120 V AC)

Output data

Nominal output voltage

24 V DC ±1

 

%

Output current

0.5 A

Can be connected in parallel/series

Yes / yes

Max. power dissipation (no load/nominal load)

< 0.3 W / < 2.2 W

Efficiency

> 84 % (for 230 V AC and nominal values)

> 84 % (for 230 V AC and nominal values)

> 84 % (for 230 V AC and nominal valu

Residual ripple

< 20 mV

PP

Signaling

Signaling DC OK

LED

General data

Weight / Dimensions W x H x D

0.07 kg / 18 x 90 x 61 mm

0.11 kg / 36 x 90 x 43 mm

0.11 kg / 36 x 90 x 61 mm

0.07 kg / 18 x 90 x 61 

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 m

Connection method

Screw connection

Connection data solid/stranded/AWG

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / II

MTBF (IEC 61709, SN 29500)

1567000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VD

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

Budgetary standard

-

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

Limitation of harmonic line currents

EN 61000-3-2

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

STEP-PS/ 1AC/24DC/0.5

2868596

1

238

PHOENIX CONTACT

STEP POWER power supplies – 
for installation distributors and flat 
control panels

STEP POWER, 1 AC, 24 V DC

– Flexible assembly by simply snapping the 

product onto the DIN rail or screwing it 
onto an even surface

– Energy savings thanks to maximum 

energy efficiency and incredibly low no-
load losses

– Wide temperature range from -25°C to 

+70°C

– Reliable supply thanks to the high MTBF 

(mean time between failure)

STEP POWER, 24 V DC, 0.5 A

– Slim design with an overall width of just 

18 mm (1 pitch)

STEP POWER, 24 V DC, 0.75 A

– Meets standard EN 60335-1 for 

household appliances, suitable for 
installation in ventilation systems, 
for example

– Flat design with a depth of just 43 mm

STEP POWER, 48 V AC, 0.5 A

– Connection to 48 V AC operating 

networks

– Slim design with an overall width of just 

18 mm (1 pitch)

Power supplies and UPS

Power supplies

H

W

D

Power supply,

1 AC, 24 V DC, 0.5 A

NEC Class 2

phoenixcontact-protection-html.html
background image

N (-)

L (+)

+

+


N (-)

L (+)

+

+


+
-

L

N

(

-)

(

+)

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

Ex: 

 

 

 

 DNV GL 

 

 

 

 

Ex: 

 

 

 

Technical data

Technical data

Technical data

100 V AC ... 240 V AC

100 V AC ... 240 V AC

48 V AC

85 V AC ... 264 V AC

95 V DC ... 250 V DC

85 V AC ... 264 V AC

95 V DC ... 250 V DC

43 V AC ... 52 V AC

60 V DC ... 80 V DC

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

0.28 A (120 V AC) / 0.13 A (230 V AC)

0.3 A (120 V AC) / 0.25 A (230 V AC)

0.3 A (120 V AC) / 0.2 A (230 V AC)

0.5 A (43 V AC) / 0.45 A (48 V

 

 AC)

<

 

15 A

 

/

 

<

 

0.1 A

2

s

<

 

15 A

 

/

 

<

 

0.1 A

2

s

<

 

10 A

 

/

 

<

 

0.1 A

2

s

> 90 ms (230 V AC)

> 15 ms (120 V AC)

 

/

 

> 70 ms (230 V AC)

> 15 ms (120 V AC)

 

/

 

> 70 ms (230 V AC)

> 15 ms (48 V

 

 AC)

 

/

 

> 20 ms (52 V AC)

24 V DC ±1

 

%

24  V  DC  ±1

 

%

24  V  DC  ±1

 

%

0.75 A

0.75 A

0.5 A

Yes / yes

Yes / yes

Yes / yes

< 0.5 W / < 3.6 W

0.5 W / 3.6 W

< 0.3 W / < 3.4 W

Efficiency

> 84 % (for 230 V AC and nominal values)

> 84 % (for 230 V AC and nominal values)

> 84 % (for 230 V AC and nominal values)

> 81 % (for 48 V

 

AC and nominal values)

< 75 mV

PP

< 75 mV

PP

< 30 mV

PP

LED

LED

LED

Weight / Dimensions W x H x D

0.07 kg / 18 x 90 x 61 mm

0.11 kg / 36 x 90 x 43 mm

0.11 kg / 36 x 90 x 61 mm

0.07 kg / 18 x 90 x 61 mm

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Screw connection

Screw connection

Screw connection

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / II

IP20 / II

IP20 / II

> 926000 h (40°C)

> 926000 h (40°C)

1860000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55 °C derating: 2.5%/K)

AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

IEC 60335-1

IEC 60335-1

-

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,

NEC Class 2 as per UL 1310

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

STEP-PS/ 1AC/24DC/0.75/FL

2868622

1

STEP-PS/ 1AC/24DC/0.75

2868635

1

STEP-PS/48AC/24DC/0.5

2868716

1

239

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

H

W

D

H

W

D

Power supply,

1 AC, 24 V DC, 0.75 A

flat design, NEC Class 2

Power supply,

1 AC, 24 V DC, 0.75 A

NEC Class 2

Power supply,

48 V AC, 24 V DC, 0.5 A

NEC Class 2

phoenixcontact-protection-html.html
background image

N (-)

L (+)

+

+


N (-)

L (+)

+

+


 

 

 

 

 

Ex: 

 

 

 

 DNV GL 

 

 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

100 V AC ... 240 V AC

Input voltage range

85 V AC ... 264 V AC

95 V DC ... 250 V DC

85 V AC ... 264 V AC

95 V DC ... 250 V DC

Frequency range

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

0.6 A (120 V AC) / 0.3 A (230 V AC)

0.8 A (120 V AC) / 0.4 A (230 V AC)

1.3 A (120 V AC) / 0.8 

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

<

 

0.6 A

2

s

<

 

15 A

 

/

 

<

 

0.6 A

2

s

Mains buffering (I

N

, typ.)

> 25 ms (120 V AC)

 

/

 

> 150 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 100 ms (230 V AC)

> 25 ms (120 V AC)

Output data

Nominal output voltage

24 V DC ±1

 

%

24  V  DC  ±1

 

%

Setting range of the output voltage (U

Set

)

22.5 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

22.5 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

22.5 V DC ... 25 V DC (> 24 V

Output current

1.75 A

2.5 A

Can be connected in parallel/series

Yes / yes

Yes / yes

Max. power dissipation (no load/nominal load)

< 0.7 W / 5 W

< 0.7 W / 9.9 W

Efficiency

> 89 % (for 230 V AC and nominal values)

> 86 % (for 230 V AC and nominal values)

> 88 % (for 230 V AC and nominal valu

Residual ripple

< 60 mV

PP

< 80 mV

PP

Signaling

Signaling DC OK

LED

LED

General data

Weight / Dimensions W x H x D

0.19 kg / 54 x 90 x 61 mm

0.27 kg / 72 x 90 x 61 mm

0.33 kg / 90 x 90 x 61 mm

0.33 kg / 90 x 90 x 61 

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 m

Connection method

Screw connection

Screw connection

Connection data solid/stranded/AWG

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / II

IP20 / II

MTBF (IEC 61709, SN 29500)

> 

1569000

 h (40°C)

> 

1061000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IE

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

STEP-PS/ 1AC/24DC/1.75

2868648

1

STEP-PS/ 1AC/24DC/2.5

2868651

1

240

PHOENIX CONTACT

STEP POWER, 1 AC, 24 V DC

– Flexible assembly by simply snapping the 

product onto the DIN rail or screwing it 
onto an even surface

– Energy savings thanks to maximum 

energy efficiency and incredibly low no-
load losses

– Wide temperature range from -25°C to 

+70°C

– Reliable supply thanks to the high MTBF 

(mean time between failure)

STEP POWER, NEC Class 2

– Output power limited to 100 W: 

Specifically for applications that require 
certification according to 
UL 1310/508 Listed Class 2

STEP POWER power supplies – 
for installation distributors and flat 
control panels

Power supplies and UPS

Power supplies

Power supply,

1 AC, 24 V DC, 1.75 A

NEC Class 2

Power supply,

1 AC, 24 V DC, 2.5 A

NEC Class 2

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

N (-)

L (+)

+

+


N (-)

L (+)

+

+


N (-)

L (+)

+

+


For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

Ex: 

 

 

 

 

 

Ex: 

 

 

 

Technical data

Technical data

Technical data

100 V AC ... 240 V AC

100 V AC ... 240 V AC

100 V AC ... 277 V AC

85 V AC ... 264 V AC

95 V DC ... 250 V DC

85 V AC ... 264 V AC

95 V DC ... 250 V DC

85 V AC ... 305 V AC

95 V DC ... 250 V DC

45 Hz ... 65 Hz

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

0.6 A (120 V AC) / 0.3 A (230 V AC)

0.8 A (120 V AC) / 0.4 A (230 V AC)

1.3 A (120 V AC) / 0.8 A (230 V AC)

1.3 A (120 V AC) / 0.8 A (230 V AC)

1.43 A (120 V AC) / 0.75 A (277 V AC)

<

 

15 A

 

/

 

<

 

1 A

2

s

<

 

15 A

 

/

 

<

 

1 A

2

s

<

 

40 A

 

/

 

<

 

2.8 A

2

s

> 100 ms (230 V AC)

> 25 ms (120 V AC)

 

/

 

> 120 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 100 ms (230 V AC)

> 25 ms (120 V AC)

 

/

 

> 160 ms (277 V AC)

24 V DC ±1

 

%

24  V  DC  ±1

 

%

24 V DC  ±1

 

%

DC, constant capacity restricted)

22.5 V DC ... 25 V DC (> 24 V

 

DC, constant capacity restricted)

22.5 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

22.5 V DC ... 25 V DC (> 24 V

 

DC, constant capacity restricted)

3.8 A

4.2 A

3.5 A

No / No

Yes / yes

Yes / yes

< 0.7 W / 11.8 W

< 0.7 W / 13.2 W

< 0.6 W / 11.5 W

Efficiency

> 89 % (for 230 V AC and nominal values)

> 86 % (for 230 V AC and nominal values)

> 88 % (for 230 V AC and nominal values)

> 88 % (for 230 V AC and nominal values)

> 88 % (for 277 V AC and nominal values)

< 80 mV

PP

< 40 mV

PP

< 10 mV

PP

LED

LED

LED

Weight / Dimensions W x H x D

0.19 kg / 54 x 90 x 61 mm

0.27 kg / 72 x 90 x 61 mm

0.33 kg / 90 x 90 x 61 mm

0.33 kg / 90 x 90 x 61 mm

0.3 kg / 90 x 90 x 61 mm

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Screw connection

Screw connection

Screw connection

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / II

IP20 / II

IP20 / II

> 897000 h (40°C)

> 897000 h (40°C)

> 

1094000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

NEC Class 2 as per UL 1310

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

STEP-PS/ 1AC/24DC/3.8/C2LPS

2868677

1

STEP-PS/ 1AC/24DC/4.2

2868664

1

STEP-PS/277AC/24DC/3.5

2904945

1

241

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

Power supply,

1 AC, 24 V DC, 100 W

NEC Class 2

Power supply,

1 AC, 24 V DC, 4.2 A

Power supply,

1 AC, 24 V DC, 3.5 A

Input up to 277 V AC, NEC Class 2

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

+
-

L

N

(

-)

(

+)

 

 

 

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

Input voltage range

85 V AC ... 264 V AC

95 V DC ... 250 V DC

Frequency range

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

0.2 A (120 V AC) / 0.13 A (230 V AC)

0.5 A (120 V AC) / 0.3 A (230 V AC)

0.8 A (120 V AC) / 0.5

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

<

 

0.1 A

2

s

Mains buffering (I

N

, typ.)

> 25 ms (120 V AC)

 

/

 

> 110 ms (230 V AC)

> 25 ms (120 V AC)

Output data

Nominal output voltage

5 V DC ±1

 

%

Setting range of the output voltage (U

Set

)

-

Output current

2 A

Can be connected in parallel/series

Yes / yes

Max. power dissipation (no load/nominal load)

< 0.4 W / < 2.6 W

Efficiency

> 81 % (for 230 V AC and nominal values)

> 80 % (for 230 V AC and nominal values)

> 87 % (for 230 V AC and nominal valu

Residual ripple

< 50 mV

PP

Signaling

Signaling DC OK

LED

General data

Weight / Dimensions W x H x D

0.1 kg / 18 x 90 x 61 mm

0.27 kg / 72 x 90 x 61 mm

0.27 kg / 72 x 90 x 61 mm

0.33 kg / 90 x 90 x 61 m

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 m

Connection method

Screw connection

Connection data solid/stranded/AWG

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / II

MTBF (IEC 61709, SN 29500)

1812000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VD

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

NEC Class 2 as per UL 1310

Limitation of harmonic line currents

EN 61000-3-2

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply,

 primary-switched, 1-phase

STEP-PS/ 1AC/ 5DC/2

2320513

1

242

PHOENIX CONTACT

STEP POWER power supplies – 
for installation distributors and flat 
control panels

STEP POWER, 1 AC, 5 to 48 V DC

– Flexible assembly by simply snapping the 

product onto the DIN rail or screwing it 
onto an even surface

– Energy savings thanks to maximum 

energy efficiency and incredibly low no-
load losses

– Wide temperature range from -25°C to 

+70°C

– Reliable supply thanks to the high MTBF 

(mean time between failure)

STEP POWER, 5 V DC, 2 A

– Slim design with an overall width of just 

18 mm (1 pitch)

STEP POWER, 5 V DC, 6.5 A

– Adjustable output voltage of 4 to 

6.5 V DC

STEP POWER, 15 V DC, 4 A

– Adjustable output voltage of 10 to 

16.5 V DC

STEP POWER, 48 V DC, 2 A

– Adjustable output voltage of 30 to 

56 V DC

Power supplies and UPS

Power supplies

H

W

D

Power supply,

1 AC, 5 V DC, 2 A

NEC Class 2

phoenixcontact-protection-html.html
background image

N (-)

L (+)

+

+


N (-)

L (+)

+

+


N (-)

L (+)

+

+


For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

Ex: 

 

 

 

 

 

Ex: 

 

 

 

 

 

Ex: 

Technical data

Technical data

Technical data

100 V AC ... 240 V AC

100 V AC ... 240 V AC

100 V AC ... 240 V AC

85 V AC ... 264 V AC

95 V DC ... 250 V DC

85 V AC ... 264 V AC

95 V DC ... 250 V DC

85 V AC ... 264 V AC

95 V DC ... 250 V DC

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

0.2 A (120 V AC) / 0.13 A (230 V AC)

0.5 A (120 V AC) / 0.3 A (230 V AC)

0.8 A (120 V AC) / 0.5 A (230 V AC)

1.3 A (120 V AC) / 0.8 A (230 V AC)

<

 

15 A

 

/

 

<

 

0.6 A

2

s

<

 

15 A

 

/

 

<

 

0.6 A

2

s

<

 

15 A

 

/

 

<

 

1.4 A

2

s

> 110 ms (230 V AC)

> 25 ms (120 V AC)

 

/

 

> 140 ms (230 V AC)

> 27 ms (120 V AC)

 

/

 

> 120 ms (230 V AC)

> 20 ms (120 V AC)

 

/

 

> 120 ms (230 V AC)

5 V DC ±1

 

%

15  V  DC  ±1

 

%

48  V  DC  ±1

 

%

4 V DC ... 6.5 V DC (> 5

 

V

 

DC, constant capacity restricted)

10 V DC ... 16.5 V DC (> 15 V

 

DC, constant capacity restricted)

30 V DC ... 56 V DC (> 48

 

V

 

DC, constant capacity restricted)

6.5 A

4 A

2 A

Yes / yes

Yes / yes

Yes / yes

< 0.4 W / 8.1 W

< 0.5 W / 8.6 W

< 0.9 W / 9.6 W

Efficiency

> 81 % (for 230 V AC and nominal values)

> 80 % (for 230 V AC and nominal values)

> 87 % (for 230 V AC and nominal values)

> 90 % (for 230 V AC and nominal values)

< 50 mV

PP

< 55 mV

PP

< 30 mV

PP

LED

LED

LED

Weight / Dimensions W x H x D

0.1 kg / 18 x 90 x 61 mm

0.27 kg / 72 x 90 x 61 mm

0.27 kg / 72 x 90 x 61 mm

0.33 kg / 90 x 90 x 61 mm

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Screw connection

Screw connection

Screw connection

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / II

IP20 / II

IP20 / II

1111000

 h (40°C)

1134000

 h (40°C)

1048000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

STEP-PS/ 1AC/ 5DC/6.5

2868541

1

STEP-PS/ 1AC/15DC/4

2868619

1

STEP-PS/ 1AC/48DC/2

2868680

1

243

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

H

W

D

H

W

D

Power supply,

1 AC, 5 V DC, 6.5 A

Power supply,

1 AC, 15 V DC, 4 A

Power supply,

1 AC, 48 V DC, 2 A

phoenixcontact-protection-html.html
background image

+
-

L

N

(

-)

(

+)

N (-)

L (+)

+

+


 

 

 

Ex: 

 

 

 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

100 V AC ... 240 V AC

Input voltage range

85 V AC ... 264 V AC

95 V DC ... 250 V DC

85 V AC ... 264 V AC

95 V DC ... 250 V DC

Frequency range

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

0.26 A (120 V AC) / 0.13 A (230 V AC)

0.33 A (120 V AC) / 0.18 A (230 V AC)

0.3 A (120 V AC) / 

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

<

 

0.1 A

2

s

<

 

15 A

 

/

 

<

 

0.1 A

2

s

Mains buffering (I

N

, typ.)

> 15 ms (120 V AC)

 

/

 

> 90 ms (230 V AC)

> 15 ms (120 V AC)

 

/

 

> 70 ms (230 V AC)

> 15 ms (120 V AC)

Output data

Nominal output voltage

12 V DC ±1

 

%

12  V  DC  ±1

 

%

Setting range of the output voltage (U

Set

)

-

-

Output current

1 A

1.5 A

Can be connected in parallel/series

Yes / yes

Yes / yes

Max. power dissipation (no load/nominal load)

< 0.4 W / < 2.8 W

< 0.4 W / < 3.2 W

Efficiency

> 83 % (for 230 V AC and nominal values)

> 84 % (for 230 V AC and nominal values)

> 84 % (for 230 V AC and nominal valu

Residual ripple

< 20 mV

PP

< 75 mV

PP

Signaling

Signaling DC OK

LED

LED

General data

Weight / Dimensions W x H x D

0.07 kg / 18 x 90 x 61 mm

0.07 kg / 36 x 90 x 43 mm

0.11 kg / 36 x 90 x 61 mm

0.19 kg / 54 x 90 x 61 

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 m

Connection method

Screw connection

Screw connection

Connection data solid/stranded/AWG

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / II

IP20 / II

MTBF (IEC 61709, SN 29500)

> 

1478000

 h (40°C)

> 

1800000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage input/output

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IE

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410

Budgetary standard

-

IEC 60335-1

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply, 

primary-switched

STEP-PS/ 1AC/12DC/1

2868538

1

STEP-PS/ 1AC/12DC/1.5/FL

2868554

1

244

PHOENIX CONTACT

STEP POWER, 1 AC, 12 V DC

– Flexible assembly by simply snapping the 

product onto the DIN rail or screwing it 
onto an even surface

– Energy savings thanks to maximum 

energy efficiency and incredibly low no-
load losses

– Wide temperature range from -25°C to 

+70°C

– Reliable supply thanks to the high MTBF 

(mean time between failure)

STEP POWER, 12 V DC, 1.5 A

– Meets standard EN 60335-1 for 

household appliances, suitable for 
installation in ventilation systems, 
for example

STEP POWER power supplies – 
for installation distributors and flat 
control panels

Power supplies and UPS

Power supplies

Power supply,

1 AC, 12 V DC, 1 A

NEC Class 2

Power supply,

1 AC, 12 V DC, 1.5 A

Flat design, NEC Class 2

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

N (-)

L (+)

+

+


N (-)

L (+)

+

+


N (-)

L (+)

+

+


For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

Ex: 

 

 

 

 

 

Ex: 

 

 

 

 

 

Ex: 

Technical data

Technical data

Technical data

100 V AC ... 240 V AC

100 V AC ... 240 V AC

100 V AC ... 240 V AC

85 V AC ... 264 V AC

95 V DC ... 250 V DC

85 V AC ... 264 V AC

95 V DC ... 250 V DC

85 V AC ... 264 V AC

95 V DC ... 250 V DC

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

45 Hz ... 65 Hz / 0 Hz

Current consumption (nominal load)

0.26 A (120 V AC) / 0.13 A (230 V AC)

0.33 A (120 V AC) / 0.18 A (230 V AC)

0.3 A (120 V AC) / 0.2 A (230 V AC)

0.6 A (120 V AC) / 0.3 A (230 V AC)

0.8 A (120 V AC) / 0.5 A (230 V AC)

<

 

15 A

 

/

 

<

 

0.1 A

2

s

<

 

15 A

 

/

 

<

 

0.6 A

2

s

<

 

15 A

 

/

 

<

 

0.6 A

2

s

> 70 ms (230 V AC)

> 15 ms (120 V AC)

 

/

 

> 70 ms (230 V AC)

> 26 ms (120 V AC)

 

/

 

> 160 ms (230 V AC)

> 27 ms (120 V AC)

 

/

 

> 120 ms (230 V AC)

12 V DC ±1

 

%

12  V  DC  ±1

 

%

12 V DC  ±1

 

%

-

10 V DC ... 16.5 V DC (> 12 V

 

DC, constant capacity restricted)

10 V DC ... 16.5 V DC (> 12 V

 

DC, constant capacity restricted)

1.5 A

3 A

5 A

Yes / yes

Yes / yes

Yes / yes

< 0.4 W / < 3.2 W

< 0.5 W / 6.4 W

< 0.5 W / 8.6 W

Efficiency

> 83 % (for 230 V AC and nominal values)

> 84 % (for 230 V AC and nominal values)

> 84 % (for 230 V AC and nominal values)

> 85 % (for 230 V AC and nominal values)

> 87 % (for 230 V AC and nominal values)

< 75 mV

PP

< 40 mV

PP

< 55 mV

PP

LED

LED

LED

Weight / Dimensions W x H x D

0.07 kg / 18 x 90 x 61 mm

0.07 kg / 36 x 90 x 43 mm

0.11 kg / 36 x 90 x 61 mm

0.19 kg / 54 x 90 x 61 mm

0.27 kg / 72 x 90 x 61 mm

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Screw connection

Screw connection

Screw connection

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / II

IP20 / II

IP20 / II

1800000

 h (40°C)

> 

1689000

 h (40°C)

1134000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

IEC 60335-1

-

-

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location) , NEC Class 2 as per UL 1310

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

STEP-PS/ 1AC/12DC/1.5

2868567

1

STEP-PS/ 1AC/12DC/3

2868570

1

STEP-PS/ 1AC/12DC/5

2868583

1

245

PHOENIX CONTACT

Power supplies and UPS

Power supplies

H

W

D

Power supply,

1 AC, 12 V DC, 1.5 A

NEC Class 2

Power supply,

1 AC, 12 V DC, 3 A

NEC Class 2

Power supply,

1 AC, 12 V DC, 5 A

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

246

PHOENIX CONTACT

Power supplies and UPS

DC/DC converters

QUINT and MINI DC/DC converters 
alter the voltage level, regenerate the 
voltage at the end of long cables, or 
enable the creation of independent 
supply systems by means of electrical 
isolation.

There are numerous fields of application 

for DC/DC converters. As the name 
suggests, they convert voltages in order to 
match different voltage levels to one 
another. On long supply lines, they raise the 
voltage to compensate for voltage drops.

DC/DC converters separate circuits from 

each other by means of electrical isolation 
and protect the sensitive loads by 
decoupling them. The primary-switched 
switching devices have an internal 
intermediate circuit. This acts as a filter. This 
means, for example, that grounded and non-
grounded circuits can be kept separate. 
Another advantage is the protection of 
critical loads from disruptive voltage 
fluctuations: if, for example, a motor is 
switched on that requires a high current for 
the starting torque, there is a brief voltage 
dip and sensitive loads shut down. The same 
occurs when loads with high input capacities 
are switched on. Troubleshooting these 
temporary faults is often difficult and time-
consuming.

DC/DC converters are also ideal in 

battery-supported power supply networks 
or solutions with unregulated transformers, 
when sensitive loads require a stable DC.

QUINT POWER – maximum 
functionality

Cost-effective selective fuse protection 

with SFB Technology:

In order to trip miniature circuit breakers 

magnetically and quickly, power supplies 
must be able to supply several times the 
nominal current for a short period. With 
SFB (Selective Fuse Breaking) Technology, 
which supplies up to 6 times the nominal 
current for 12 ms, a dynamic power reserve 
is available. Faulty current paths are 
switched off selectively, the fault is located, 
and important system parts remain in 
operation.

Preventive function monitoring:
Comprehensive diagnostics are provided 

through constant monitoring of the input 
voltage, output voltage, and output current. 
This preventive monitoring visualizes critical 
operating states, before errors can occur. 
Remote monitoring is provided by means of 
active switching outputs and floating relay 
contacts.

Power Boost power reserve:
The static power reserve offers up to 1.25 

times the nominal current permanently. At 
ambient temperatures of up to +40°C the 
Power Boost is continuously available and at 
higher temperatures it is available for a few 
minutes. This ensures that both high switch-
on currents of capacitive loads, as well as 
loads with DC/DC converters in the 
primary circuit can be reliably supplied.

Your web code: 

#0152

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

247

PHOENIX CONTACT

Power supplies and UPS

DC/DC converters

QUINT POWER

The unique SFB Technology and 

preventive function monitoring maximize 
the availability of your application.
– Quick tripping of standard circuit 

breakers with SFB Technology

– Preventive function monitoring
– Reliable starting of heavy loads with 

Power Boost

QUINT POWER CO with protective 
coating for extreme requirements

The protective coating on these DC/DC 

converters protects against dust, corrosive 
gases, and 100% humidity as well as failure 
caused by corrosion-related creepage 
currents and electrochemical migration.
– OVP (overvoltage protection) limits surge 

voltages to 32 V

– Wide temperature range from -40°C to 

+70°C

MINI DC/DC converters – for control 
technology

MINI DC/DC converters come into their 

own in fields where modular electronics 
housing has become the standard.
– Maintenance-friendly connection 

technology with coded COMBICON 
connectors

– Active function monitoring with switching 

output for remote monitoring of the 
output voltage

Voltage levels of QUINT DC/DC 
converters with 12 to 48 V DC

The QUINT DC/DC converters alter the 

voltage level:
– Input voltages: 

12 V DC (9 ... 18 V DC), 
24 V DC (18 ... 32 V DC), 
48 V DC (30 ... 60 V DC)

– Output voltages: 

12 V DC (5 ... 18 V DC), 
24 V DC (18 ... 29.5 V DC), 
48 V DC (30 ... 56 V DC)      

Voltage levels of QUINT DC/DC 
converters with 60 to 110 V DC

The QUINT DC/DC converters alter the 

voltage level:
– Input voltages: 

60 to 72 V DC (42 ... 96 V DC), 
96 to 110 V DC (67 ... 154 V DC)  

– Output voltages: 

24 V DC (18 ... 29.5 V DC)  

Voltage levels of MINI DC/DC 
converters

The MINI DC/DC converters alter the 

voltage level:
– Input voltages: 

12 to 24 V DC (10 ... 32 V DC), 
48 to 60 V DC (36 ... 75 V DC)

– Output voltages: 

5 to 15 V DC (5 ...15 V DC), 
24 V DC (22.5 ... 28.5 V DC), 
48 V DC (30 ... 56 V DC)

phoenixcontact-protection-html.html
background image

DC O

K

U

>1

9

,2 V

IN

I<I

N

+

+

+

-

-
-

-

D

C

O

K

U

>

1

9

,

2

V

I

N

I<I

N

13

14

+

+

+

-

-
-

-

 

 

 

 

 

 

 

 

 

Ex: 

 

 

 

 

 

 

 

 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

24 V DC

24 V DC

Current consumption (Power

 

Boost)

7 A (24 V, I

BOOST

)

14  A  (24  V,  I

BOOST

)

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

<

 

0.5 A

2

s

<

 

15 A

 

/

 

<

 

2.7 A

2

s

Mains buffering (I

N

, typ.)

> 10 ms (24 V DC)

> 12 ms (24 V DC)

Output data

Nominal output voltage

24 V DC ±1

 

%

24  V  DC  ±1

 

%

Setting range of the output voltage (U

Set

)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

Output current / Power

 

Boost / SFB (12 ms)

5 A / 6.25 A / 30 A

10 A / 12.5 A / 60 A

Magnetic circuit breaker tripping

B2 / B4 / C2

B2 / B4 / B6 / C2 / C4

Can be connected in parallel/series

Yes / yes

Yes / yes

Max. power dissipation (no load/nominal load)

2.4 W / 11.4 W

1.6 W / 24 W

Efficiency

> 92 %

> 92 %

Residual ripple

< 20 mV

PP

< 20 mV

PP

Signaling

Signaling DC OK

LED, active switching output

LED, active switching output, relay contact

LED, active switching output, relay conta

Boost signaling

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

U

IN

 signaling

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

LED, 

General data

Weight / Dimensions W x H x D

0.7 kg / 32 x 130 x 125 mm

0.9 kg / 48 x 130 x 125 mm

1.7 kg / 82 x 130 x 125 mm

0.7 kg / 32 x 130 x 

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Plug-in screw connection

Plug-in screw connection

Screw connection

Plug-in screw connection

Plug-in screw connecti

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.5

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / III

IP20 / III

MTBF (IEC 61709, SN 29500)

> 890000 h (40°C)

> 763000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K, startup at -40°C type-

tested)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K, startup at -40°C type-

Max. permissible relative humidity (operation)

 95 % (at 25 °C, non-condensing)

 95 % (at 25 °C, non-condensing)

Standards/regulations

Insulation voltage input/output

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine te

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 609

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

DC/DC converter,

 primary-switched

QUINT-PS/24DC/24DC/ 5

2320034

1

QUINT-PS/24DC/24DC/10

2320092

1

248

PHOENIX CONTACT

QUINT POWER, 24 V DC input

– Support conversion to various voltage 

levels

– Constant voltage: output voltage 

regenerated even at the end of long 
cables

– Electrical isolation: for setting up 

independent supply systems

– SFB Technology: fast tripping of standard 

circuit breakers, thanks to the dynamic 
power reserve with up to 6 times the 
nominal current for 12 ms

– Reliable starting of heavy loads thanks to 

the static Power Boost power reserve 
with up to 125% of the nominal current

– Preventive function monitoring

QUINT DC/DC converters

Power supplies and UPS

DC/DC converters

DC/DC converter,

24 V DC / 24 V DC, 5 A

DC/DC converter,

24 V DC / 24 V DC, 10 A

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

D

C

O

K

U

>

1

9

,

2

V

I

N

I<I

N

13

14

+

+

+

-

-
-

-

DC O

K

U

>1

9

,2 V

IN

I<I

N

+

+

+

-

-
-

-

D

C

O

K

U

>

1

9

,

2

V

I

N

I<I

N

13

14

+

+

+

-

-
-

-

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

Ex: 

 

 

 

 

 

 

 

 

 

Ex: 

 

 

 

 

 

 

 

 

 

Ex: 

Technical data

Technical data

Technical data

24 V DC

24 V DC

24 V DC

28 A (24 V, I

BOOST

)

6 A (24 V, I

BOOST

)

14 A (24 V, I

BOOST

)

<

 

26 A

 

/

 

<

 

11 A

2

s

<

 

15 A

 

/

 

<

 

0.5 A

2

s

<

 

15 A

 

/

 

3 A

2

s

> 10 ms (24 V DC)

> 10 ms (24 V DC)

> 12 ms (24 V DC)

24 V DC ±1

 

%

12  V  DC  ±1

 

%

48 V DC  ±1

 

%

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

5 V DC ... 18 V DC (> 12 V

 

DC, constant capacity restricted)

30 V DC ... 56 V DC (> 48

 

V

 

DC, constant capacity restricted)

20 A / 25 A / 120 A

8 A / 10 A / 48 A

5 A / 6.25 A / 30 A

B2 / B4 / B6 / B10 / B16 / C2 / C4 / C6

B2 / B4 / C2

B2 / B4 / C2

Yes / yes

Yes / yes

Yes / yes

2.2 W / 39 W

2 W / 10.5 W

5.2 W / 21 W

> 93 %

> 90 %

> 92.5 %

< 20 mV

PP

< 20 mV

PP

< 20 mV

PP

Signaling DC OK

LED, active switching output

LED, active switching output, relay contact

LED, active switching output, relay contact

LED, active switching output

LED, active switching output, relay contact

Boost signaling

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

ut

LED, active switching output

LED, active switching output

LED, active switching output

Weight / Dimensions W x H x D

0.7 kg / 32 x 130 x 125 mm

0.9 kg / 48 x 130 x 125 mm

1.7 kg / 82 x 130 x 125 mm

0.7 kg / 32 x 130 x 125 mm

0.9 kg / 48 x 130 x 125 mm

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Plug-in screw connection

Plug-in screw connection

Screw connection

Plug-in screw connection

Plug-in screw connection

12

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 8

 

-

 

6

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 12

 

-

 

10

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / III

IP20 / III

IP20 / III

> 554000 h (40°C)

> 843000 h (40°C)

> 761000 h (40°C)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K, startup at -40°C type-

tested)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K, startup at -40°C type-

tested)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K, startup at -40°C type-

tested)

 95 % (at 25 °C, non-condensing)

 95 % (at 25 °C, non-condensing)

 95 % (at 25 °C, non-condensing)

test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

QUINT-PS/24DC/24DC/20

2320102

1

QUINT-PS/24DC/12DC/ 8

2320115

1

QUINT-PS/24DC/48DC/ 5

2320128

1

249

PHOENIX CONTACT

Power supplies and UPS

DC/DC converters

H

W

D

DC/DC converter,

24 V DC / 24 V DC, 20 A

DC/DC converter,

24 V DC / 12 V DC, 8 A

DC/DC converter,

24 V DC / 48 V DC, 5 A

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

DC

 

O

K

U

>

9

,6V

IN

I<I

N

 

 

 

 

 

 

 

 

 

Ex: 

Technical data

Input data

Nominal input voltage range

12 V DC

Current consumption (Power

 

Boost)

15 A (12 V, I

BOOST

)

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

<

 

0.3 A

2

s

Mains buffering (I

N

, typ.)

> 3 ms (12 V DC)

Output data

Nominal output voltage

24 V DC ±1

 

%

Setting range of the output voltage (U

Set

)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

5 V DC ... 18 V DC (> 12 V

Output current / Power

 

Boost / SFB (12 ms)

5 A / 6.25 A / 30 A

Magnetic circuit breaker tripping

B2 / B4 / C2

Can be connected in parallel/series

Yes / yes

Max. power dissipation (no load/nominal load)

2 W / 13.5 W

Efficiency

> 90 %

Residual ripple

< 75 mV

PP

Signaling

Signaling DC OK

LED, active switching output

LED, active switching output

Boost signaling

LED, active switching output

LED, active switching output

U

IN

 signaling

LED, active switching output

LED, active switching output

General data

Weight / Dimensions W x H x D

0.7 kg / 32 x 130 x 125 mm

0.8 kg / 32 x 130 x 125 mm

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Plug-in screw connection

Plug-in screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 18

 

-

 

12

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 18

 

-

 

12

0.2

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / III

MTBF (IEC 61709, SN 29500)

1005000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

Max. permissible relative humidity (operation)

 95 % (at 25 °C, non-condensing)

Standards/regulations

Insulation voltage input/output

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

Safe isolation

DIN VDE 0100-410

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Description

Type

Order No.

Pcs./Pkt.

DC/DC converter,

 primary-switched

QUINT-PS/12DC/24DC/ 5

2320131

1

250

PHOENIX CONTACT

QUINT DC/DC converters

QUINT POWER, 12 V DC input

– Support conversion to various voltage 

levels

– Constant voltage: output voltage 

regenerated even at the end of long 
cables

– Electrical isolation: for setting up 

independent supply systems

– SFB Technology: fast tripping of standard 

circuit breakers, thanks to the dynamic 
power reserve with up to 6 times the 
nominal current for 12 ms

– Reliable starting of heavy loads thanks to 

the static Power Boost power reserve 
with up to 125% of the nominal current

– Preventive function monitoring

Power supplies and UPS

DC/DC converters

H

W

D

DC/DC converter,

12 V DC / 24 V DC, 5 A

phoenixcontact-protection-html.html
background image

DC

 

O

K

U

>

9

,6V

IN

I<I

N

For further information and full technical data, visit phoenixcontact.net/products

Ex: 

Technical data

12 V DC

12 A (12 V, I

BOOST

)

<

 

6 A

 

/

 

<

 

0.6 A

2

s

> 3 ms (12 V DC)

12 V DC ±1

 

%

DC, constant capacity restricted)

5 V DC ... 18 V DC (> 12 V

 

DC, constant capacity restricted)

8 A / 10 A / 48 A

B2 / B4 / C2

Yes / yes

1.5 W / 11.8 W

> 89 %

< 20 mV

PP

Signaling DC OK

LED, active switching output

LED, active switching output

Boost signaling

LED, active switching output

LED, active switching output

 signaling

LED, active switching output

LED, active switching output

Weight / Dimensions W x H x D

0.7 kg / 32 x 130 x 125 mm

0.8 kg / 32 x 130 x 125 mm

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Plug-in screw connection

Plug-in screw connection

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / III

> 920000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

 95 % (at 25 °C, non-condensing)

kV (type test)

1 kV (routine test) / 1.5 kV (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Type

Order No.

Pcs./Pkt.

QUINT-PS/12DC/12DC/8

2905007

1

251

PHOENIX CONTACT

Power supplies and UPS

DC/DC converters

H

W

D

DC/DC converter,

12 V DC/12 V DC, 8 A

phoenixcontact-protection-html.html
background image

DC O

K

U >

3

8,4 V

I

N

I<I

N

+

+

+

-

-
-

-

 

 

 

 

 

 

 

 

 

Ex: 

Technical data

Input data

Nominal input voltage range

48 V DC

Current consumption (Power

 

Boost)

3.5 A (48 V DC)

Inrush current limitation at 25°C / I

2

t

<

 

5 A

 

/

 

<

 

0.2 A

2

s

Mains buffering (I

N

, typ.)

> 14 ms (48 V DC)

Output data

Nominal output voltage

24 V DC ±1

 

%

Setting range of the output voltage (U

Set

)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

30 V DC ... 56 V DC (> 48

Output current / Power

 

Boost / SFB (12 ms)

5 A / 6.25 A / 30 A

Magnetic circuit breaker tripping

B2 / B4 / C2

Can be connected in parallel/series

Yes / yes

Max. power dissipation (no load/nominal load)

2.7 W / 11 W

Efficiency

> 91.5 %

Residual ripple

< 25 mV

PP

Signaling

Signaling DC OK

LED, active switching output

LED, active switching output

LED, active switching output, relay contact

LED, active s

Boost signaling

LED, active switching output

LED, active switching 

U

IN

 signaling

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

General data

Weight / Dimensions W x H x D

0.7 kg / 32 x 130 x 125 mm

0.9 kg / 48 x 130 x 125 mm

1 kg / 48 x 130 x 125 mm

0.9 kg / 48 x 130 x 12

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / III

MTBF (IEC 61709, SN 29500)

> 995000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ...

Max. permissible relative humidity (operation)

 95 % (at 25 °C, non-condensing)

Standards/regulations

Insulation voltage input/output

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine te

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Description

Type

Order No.

Pcs./Pkt.

DC/DC converter,

 primary-switched

QUINT-PS/48DC/24DC/ 5

2320144

1

252

PHOENIX CONTACT

QUINT DC/DC converters

QUINT POWER, 48 V DC to 
110 V DC input

– Support conversion to various voltage 

levels

– Constant voltage: output voltage 

regenerated even at the end of long 
cables

– Electrical isolation: for setting up 

independent supply systems

– SFB Technology: fast tripping of standard 

circuit breakers, thanks to the dynamic 
power reserve with up to 6 times the 
nominal current for 12 ms

– Reliable starting of heavy loads thanks to 

the static Power Boost power reserve 
with up to 125% of the nominal current

– Preventive function monitoring

Power supplies and UPS

DC/DC converters

H

W

D

DC/DC converter,

48 V DC / 24 V DC, 5 A

phoenixcontact-protection-html.html
background image

DC O

K

U >

3

8,4 V

I

N

I<I

N

1

3

14

+

+

+

-

-
-

-

DC O

K

U > 0.8 x U

I

N

N

I<I

N

1

3

14

+

+

+

-

-
-

-

DC O

K

U > 0.8 x U

I

N

N

I<I

N

1

3

14

+

+

+

-

-
-

-

For further information and full technical data, visit phoenixcontact.net/products

Ex: 

Ex: 

Ex: 

Technical data

Technical data

Technical data

48 V DC

60 V DC ... 72 V DC

96 V DC ... 110 V DC

7 A (48 V, I

BOOST

)

5.6 A (60 V DC) / 4.7 A (72 V DC)

3.5 A (96 V DC) / 3.1 A (110 V DC)

<

 

6 A

 

/

 

0.3 A

2

s

<

 

9 A

 

/

 

0.64 A

2

s

<

 

10 A

 

/

 

0.37 A

2

s

> 10 ms (48 V DC)

> 10 ms (60 V DC)

> 10 ms (96 V DC)

48 V DC ±1

 

%

24  V  DC  ±1

 

%

24  V  DC  ±1

 

%

DC, constant capacity restricted)

30 V DC ... 56 V DC (> 48

 

V

 

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

5 A / 6.25 A / 30 A

10 A / 12.5 A / 60 A

10 A / 12.5 A / 60 A

B2 / B4 / C2

B2 / B4 / B6

B2 / B4 / B6

Yes / yes

Yes / yes

Yes / yes

2.7 W / 20 W

4 W (U

IN

 60 V DC) / 24 W (U

IN

 60 V DC)

4 W (U

IN

 110 V DC) / 22 W (U

IN

 110 V DC)

> 93 %

> 91 % (U

IN

 60 V DC / U

OUT

 24 V DC)

 

/

 

> 91 % (U

IN

 72 V DC / U

OUT

 24 V DC)

> 92 % (U

IN

 96 V DC / U

OUT

 24 V DC)

 

/

 

> 92 % (U

IN

 110 V DC / U

OUT

 24 V DC)

< 20 mV

PP

< 20 mV

PP

< 20 mV

PP

Signaling DC OK

LED, active switching output

LED, active switching output

LED, active switching output, relay contact

LED, active switching output, relay contact

Boost signaling

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

 signaling

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

Weight / Dimensions W x H x D

0.7 kg / 32 x 130 x 125 mm

0.9 kg / 48 x 130 x 125 mm

1 kg / 48 x 130 x 125 mm

0.9 kg / 48 x 130 x 125 mm

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / III

IP20 / I

IP20 / I

> 872000 h (40°C)

> 765000 h (40°C)

> 772000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

 95 % (at 25 °C, non-condensing)

 95 % (at 25 °C, non-condensing)

 95 % (at 25 °C, non-condensing)

test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

QUINT-PS/48DC/48DC/5

2905008

1

QUINT-PS/60-72DC/24DC/10

2905009

1

QUINT-PS/96-110DC/24DC/10

2905010

1

253

PHOENIX CONTACT

Power supplies and UPS

DC/DC converters

H

W

D

H

W

D

H

W

D

DC/DC converter,

48 V DC/48 V DC, 5 A

DC/DC converter,

60 - 72 V DC/24 V DC, 10 A

DC/DC converter,

96 - 110 V DC/24 V DC, 10 A

phoenixcontact-protection-html.html
background image

DC O

K

U

>1

9

,2 V

IN

I<I

N

+

+

+

-

-
-

-

D

C

O

K

U

>

1

9

,

2

V

I

N

I<I

N

13

14

+

+

+

-

-
-

-

 

 

 

 

 

 

 

 

Ex: 

 

 

 

 

 

 

 

 

 

 

Ex: 

 

 

Technical data

Technical data

Input data

Nominal input voltage range

24 V DC

24 V DC

Current consumption (Power

 

Boost)

7 A (24 V, I

BOOST

)

14  A  (24  V,  I

BOOST

)

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

<

 

0.5 A

2

s

<

 

15 A

 

/

 

<

 

2.7 A

2

s

Mains buffering (I

N

, typ.)

> 10 ms (24 V DC)

> 12 ms (24 V DC)

Output data

Nominal output voltage

24 V DC ±1

 

%

24  V  DC  ±1

 

%

Setting range of the output voltage (U

Set

)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

Output current / Power

 

Boost / SFB (12 ms)

5 A / 6.25 A / 30 A

10 A / 12.5 A / 60 A

Magnetic circuit breaker tripping

B2 / B4 / C2

B2 / B4 / B6 / C2 / C4

Can be connected in parallel/series

Yes / yes

Yes / yes

Max. power dissipation (no load/nominal load)

2.4 W / 11.4 W

1.6 W / 24 W

Efficiency

> 92 %

> 92 %

Residual ripple

< 20 mV

PP

< 20 mV

PP

Signaling

Signaling DC OK

LED, active switching output

LED, active switching output, relay contact

LED, active switching output, relay conta

Boost signaling

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

U

IN

 signaling

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

LED, 

General data

Weight / Dimensions W x H x D

0.7 kg / 32 x 130 x 125 mm

0.9 kg / 48 x 130 x 125 mm

1.7 kg / 82 x 130 x 125 mm

1 kg / 48 x 130 x 12

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Plug-in screw connection

Plug-in screw connection

Screw connection

Plug-in screw connection

Plug-in screw connecti

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.5

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / III

IP20 / III

MTBF (IEC 61709, SN 29500)

> 890000 h (40°C)

> 763000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K, startup at -40°C type-

tested)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K, startup at -40°C type-

tested)

Max. permissible relative humidity (operation)

100 % (at 25 °C, non-condensing)

100 % (at 25 °C, non-condensing)

100 % (at 25 °C, 

Standards/regulations

Insulation voltage input/output

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine te

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 609

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410

DIN VDE 0100-410

Rail applications

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

DC/DC converter,

 primary-switched, dip-coated

QUINT-PS/24DC/24DC/ 5/CO

2320542

1

QUINT-PS/24DC/24DC/10/CO

2320555

1

254

PHOENIX CONTACT

QUINT POWER with protective 
coating

With ATEX approval for superior system 

availability under extreme ambient 
conditions, such as dust, dirt, corrosive 
gases, and 100% humidity
– Devices compliant with standards 

EN 60079-15 and EN 60079-0 may be 
installed in a potentially explosive area

– Suitable for use in Class I, Division 2
– OVP (overvoltage protection) limits surge 

voltages to 32 V

– Temperature range from -40°C to +70°C, 

Groups A, B, C, D

QUINT DC/DC converters for 
extreme ambient conditions

Power supplies and UPS

DC/DC converters

DC/DC converter,

with protective coating,

24 V DC/24 V DC, 5 A

DC/DC converter,

with protective coating,

24 V DC/24 V DC, 10 A

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

D

C

O

K

U

>

1

9

,

2

V

I

N

I<I

N

13

14

+

+

+

-

-
-

-

DC O

K

U > 0.8 x U

I

N

N

I<I

N

1

3

14

+

+

+

-

-
-

-

DC O

K

U > 0.8 x U

I

N

N

I<I

N

1

3

14

+

+

+

-

-
-

-

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

Ex: 

 

 

Ex: 

Ex: 

Technical data

Technical data

Technical data

24 V DC

60 V DC ... 72 V DC

96 V DC ... 110 V DC

28 A (24 V, I

BOOST

)

5.6 A (60 V DC) / 4.7 A (72 V DC)

3.5 A (96 V DC) / 3.1 A (110 V DC)

<

 

26 A

 

/

 

<

 

11 A

2

s

<

 

9 A

 

/

 

0.64 A

2

s

<

 

10 A

 

/

 

0.37 A

2

s

> 10 ms (24 V DC)

> 10 ms (60 V DC)

> 10 ms (96 V DC)

24 V DC ±1

 

%

24  V  DC  ±1

 

%

24 V DC  ±1

 

%

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

18 V DC ... 29.5 V DC (> 24 V

 

DC, constant capacity restricted)

20 A / 25 A / 120 A

10 A / 12.5 A / 60 A

10 A / 12.5 A / 60 A

B2 / B4 / B6 / B10 / B16 / C2 / C4 / C6

B2 / B4 / B6

B2 / B4 / B6

Yes / yes

Yes / yes

Yes / yes

2.2 W / 39 W

4 W (U

IN

 60 V DC) / 24 W (U

IN

 60 V DC)

4 W (U

IN

 110 V DC) / 22 W (U

IN

 110 V DC)

> 92 %

> 91 % (U

IN

 60 V DC / U

OUT

 24 V DC)

 

/

 

> 91 % (U

IN

 72 V DC / U

OUT

 24 V DC)

> 92 % (U

IN

 96 V DC / U

OUT

 24 V DC)

 

/

 

> 92 % (U

IN

 110 V DC / U

OUT

 24 V DC)

< 20 mV

PP

< 20 mV

PP

< 20 mV

PP

Signaling DC OK

LED, active switching output

LED, active switching output, relay contact

LED, active switching output, relay contact

LED, active switching output, relay contact

LED, active switching output, relay contact

Boost signaling

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

ut

LED, active switching output

LED, active switching output

LED, active switching output

Weight / Dimensions W x H x D

0.7 kg / 32 x 130 x 125 mm

0.9 kg / 48 x 130 x 125 mm

1.7 kg / 82 x 130 x 125 mm

1 kg / 48 x 130 x 125 mm

0.9 kg / 48 x 130 x 125 mm

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Plug-in screw connection

Plug-in screw connection

Screw connection

Plug-in screw connection

Plug-in screw connection

12

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 8

 

-

 

6

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 12

 

-

 

10

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / III

IP20 / I

IP20 / I

> 554000 h (40°C)

> 765000 h (40°C)

> 772000 h (40°C)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K, startup at -40°C type-

tested)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

Max. permissible relative humidity (operation)

100 % (at 25 °C, non-condensing)

100 % (at 25 °C, non-condensing)

100 % (at 25 °C, non-condensing)

100 % (at 25 °C, non-condensing)

100 % (at 25 °C, non-condensing)

test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

DIN VDE 0100-410

DIN VDE 0100-410

DIN VDE 0100-410

Rail applications

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

EN 50121-4 / EN 50155

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

QUINT-PS/24DC/24DC/20/CO

2320568

1

QUINT-PS/60-72DC/24DC/10/CO

2905011

1

QUINT-PS/96-110DC/24DC/10/CO

2905012

1

255

PHOENIX CONTACT

Power supplies and UPS

DC/DC converters

H

W

D

DC/DC converter,

with protective coating,

24 V DC/24 V DC, 20 A

DC/DC converter,

with protective coating,

60 - 72

 

V

 

DC/24

 

V

 

DC, 10

 

A

DC/DC converter,

with protective coating,

96 - 110

 

V

 

DC/24

 

V

 

DC, 10

 

A

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

NC

NC

DC OK

NC

NC

DC OK

 

 

 

 

Ex: 

 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

12 V DC ... 24 V DC

12 V DC ... 24 V DC

Current consumption (nominal load)

2.6 A (12 V DC) / 1.3 A (24 V DC)

2.3 A (12 V DC) / 1.1 A (24 V DC)

3.2 A (12 V DC) / 1.6 A (24

Inrush current limitation at 25°C / I

2

t

<

 

15 A

 

/

 

1.8 A

2

s

<

 

10 A

 

/

 

0.2 A

2

s

Output data

Nominal output voltage

24 V DC ±1

 

%

12  V  DC  ±1

 

%

Setting range of the output voltage (U

Set

)

22.5 V DC ... 28.5 V DC (> 24 V

 

DC, constant capacity restricted)

5 V DC ... 15 V DC

Output current

1 A

2 A

Can be connected in parallel/series

Yes / yes

Yes / yes

Max. power dissipation (no load/nominal load)

< 1.2 W / < 5 W

< 1 W / < 4.2 W

Efficiency

> 83 % (at 24 V DC and nominal values)

> 88 % (at 24 V DC and nominal values)

> 87 % (at 24 V DC and nominal values)

> 8

Residual ripple

< 30 mV

PP

< 20 mV

PP

Signaling

Signaling DC OK

LED, active switching output

LED, active switching output

LED, active switching output

LED, active switching output

General data

Weight / Dimensions W x H x D

0.2 kg / 22.5 x 99 x 107 mm

0.2 kg / 22.5 x 99 x 107 mm

0.2 kg / 22.5 x 99 x 107 mm

0.2 kg / 22.5 x 9

Assembly instructions

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can 

Connection method

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw 

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

Degree of protection / Protection class

IP20 / III

IP20 / III

MTBF (IEC 61709, SN 29500)

> 

2569000

 h (40°C)

> 

2072000

 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> +60°C derating)

-25 °C ... 70 °C (

Max. permissible relative humidity (operation)

 95 % (at 25 °C, non-condensing)

 95 % (At +25°C, non-condensing)

Standards/regulations

Insulation voltage input/output

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine te

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 609

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

Safe isolation

DIN VDE 0100-410 , DIN VDE 0106-101

DIN VDE 0100-410 , DIN VDE 0106-101

DIN VDE 0100-410 , DIN VDE 0106-101

DIN VDE 

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

DC/DC converter,

 primary-switched

MINI-PS- 12- 24DC/24DC/1

2866284

1

MINI-PS- 12- 24DC/ 5-15DC/2

2320018

1

256

PHOENIX CONTACT

MINI POWER, 12 V DC to 60 V DC 
input

– Support conversion to various voltage 

levels

– Constant voltage: output voltage 

regenerated even at the end of long 
cables

– Electrical isolation: for setting up 

independent supply systems

MINI AC power module

– For connection upstream of MINI 

DC/DC converters

– The AC voltage of a transformer is 

rectified and filtered

MINI DC/DC converters

Power supplies and UPS

DC/DC converters

DC/DC converter,

12 - 24 V DC / 24 V DC, 1 A

DC/DC converter,

12 - 24 V DC / 5 - 15 V DC, 2 A

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

NC

NC

DC OK

NC

NC

DC OK

(+)

(-)

N

C

N

C

N

C

N

C

~
~

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

Ex: 

 

 

Ex: 

 

 

 

Technical data

Technical data

Technical data

12 V DC ... 24 V DC

48 V DC ... 60 V DC

10 V AC ... 42 V AC

Current consumption (nominal load)

2.6 A (12 V DC) / 1.3 A (24 V DC)

2.3 A (12 V DC) / 1.1 A (24 V DC)

3.2 A (12 V DC) / 1.6 A (24 V DC)

0.6 A (48 V DC) / 0.5 A (60 V DC)

6.5 A

<

 

10 A

 

/

 

0.3 A

2

s

<

 

15 A

 

/

 

1.8 A

2

s

<

 

45 A

 

/

 

8 A

2

s

48 V DC ±1

 

%

24  V  DC  ±1

 

%

28 V DC  ±1

 

%

30 V DC ... 56 V DC (> 48

 

V

 

DC, constant capacity restricted)

22.5 V DC ... 28.5 V DC (> 24 V

 

DC, constant capacity restricted)

-

0.7 A

1 A

3 A

Yes / yes

Yes / yes

Yes / No

< 1.5 W / < 4.5 W

< 1.2 W / < 5 W

< 0.04 W / < 6.9 W

Efficiency

> 83 % (at 24 V DC and nominal values)

> 88 % (at 24 V DC and nominal values)

> 87 % (at 24 V DC and nominal values)

> 85 % (at 60 V DC and nominal values)

> 95.7 % (For 42 V AC and nominal values)

< 20 mV

PP

< 40 mV

PP

< 3.6 V

PP

g output

LED, active switching output

LED, active switching output

-

Weight / Dimensions W x H x D

0.2 kg / 22.5 x 99 x 107 mm

0.2 kg / 22.5 x 99 x 107 mm

0.2 kg / 22.5 x 99 x 107 mm

0.2 kg / 22.5 x 99 x 107 mm

0.16 kg / 22.5 x 99 x 107 mm

lly 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Connection method

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

Plug-in screw connection

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

- / - / -

IP20 / III

IP20 / II

IP20 / III

1993000

 h (40°C)

> 

1147000

 h (40°C)

> 18175000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> +60°C derating)

-25 °C ... 70 °C (> +60°C derating)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

 95 % (At +25°C, non-condensing)

 95 % (at 25 °C, non-condensing)

 95 % (at 25 °C, non-condensing)

test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

1 kV (routine test) / 1.5 kV (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

10 , DIN VDE 0106-101

DIN VDE 0100-410 , DIN VDE 0106-101

DIN VDE 0100-410 , DIN VDE 0106-101

-

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

MINI-PS- 12- 24DC/48DC/0.7

2320021

1

MINI-PS- 48- 60DC/24DC/1

2866271

1

MINI-PS- 10- 42AC/15-60DC/3

2320199

1

257

PHOENIX CONTACT

Power supplies and UPS

DC/DC converters

H

W

D

DC/DC converter,

12 - 24 V DC / 48 V DC, 0.7 A

DC/DC converter,

48 - 60 V DC / 24 V DC, 1 A

AC power module for

MINI DC/DC converter

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

258

PHOENIX CONTACT

Power supplies and UPS

Redundancy modules

Maximum availability due to 
redundancy modules

To prevent errors influencing the load in a 

redundant system and to increase 
operational reliability, the power supplies 
must be decoupled from one another using 
a redundancy module. Phoenix Contact 
offers various solutions depending on the 
requirements:

Decoupling with diodes from the 
QUINT, TRIO, UNO, and STEP 
ranges

If the power supplies are decoupled, a 

short circuit at the output of one of the 
power supply units or in the supply line 
from the power supply unit to the diode no 
longer has any affect on the load.

Decoupling, monitoring, and closed-
loop control by means of the QUINT 
ORING active redundancy modules

The QUINT ORING active redundancy 

modules monitor the entire redundant 
solution, i.e., the power supply unit 
voltages, the wiring, decoupling, and the 
load current. Critical operating states can 
therefore be detected at an early stage and 
redundancy can be restored. E.g., incorrect 
wiring or faulty cables are indicated.

QUINT ORING with ACB Technology 

doubles the service life of the redundant 
system:

As a result of asymmetries, the load is 

often supplied by one power supply unit, 
while the other runs in no-load operation. 
This results in a thermal overload of the 
working power supply unit and therefore 
rapid aging. If the power supply unit is 
operated at half the nominal current, it 
remains significantly cooler.
The ACB Technology of the QUINT 
ORING modules ensures symmetrical 
loading of the power supplies and thereby 
up to double the service life of the 
redundant system.

Decoupling and monitoring by means 
of the QUINT S-ORING active 
redundancy modules

The QUINT S-ORING active redundancy 

modules consistently monitor the 
redundant system, in combination with the 
new QUINT POWER power supplies. With 
QUINT S-ORING, the cable is routed 
redundantly and separately up to the load.

QUINT S-ORING with protective 

coating with OVP (overvoltage protection) 
protects downstream loads from surge 
voltages greater than 30 V DC.

Your web code: 

#0153

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

259

PHOENIX CONTACT

Power supplies and UPS

Redundancy modules

ACB Technology doubles the service 
life

The ACB (Auto Current Balancing) 

Technology ensures symmetrical loading of 
the power supplies, thereby reducing the 
operating temperature. This means up to 
double the service life of the redundant 
system.

QUINT ORING for maximum system 
availability

Consistent monitoring of the redundant 

system, with energy savings of up to 70%.

QUINT ORING

– ACB  Technology
– Two positive output terminals
– Voltage limitation to < 32 V DC 

(+Version)

QUINT S-ORING

– Separate cable routing up to the load
– Voltage limitation to < 30 V DC 

(+Version)

QUINT DIODE redundancy module

– High system availability, thanks to the 

robust design

– Safe decoupling of power supplies 

connected in parallel

– Flexible: nominal voltages of 12 V DC to 

48 V DC

TRIO DIODE redundancy module

– Safe decoupling of power supplies 

connected in parallel

– Quick and easy installation, thanks to 

Push-in connection technology

– System compatible with TRIO POWER 

power supplies

UNO DIODE redundancy module

– Consistent redundancy up to the load
– Flexible: nominal voltages of 5 V DC to 

24 V DC

STEP DIODE redundancy module

– Space-saving: overall width of just 18 mm
– Consistent redundancy up to the load
– Flexible: nominal voltages of 5 V DC to 

24 V DC

phoenixcontact-protection-html.html
background image

+
+

14

23

24

+

+

I...[A]

-

-
-

IN2

IN1

O

ut

13

3

0

 V A

C/DC

1

00

 

m

A

 

 

 

 

 

 

 

 

Ex: 

 

 

Technical data

Input data

Nominal input voltage range

24 V DC

Input voltage range

18 V DC

 

...

 

28 V DC

Nominal current

2x 10 A (-25 °C ... 60 °C)

2x 20 A (-25 °C ... 60 °C)

2x 40 A (-25 °C ... 60 °C)

1x 20 A (-25 °C ... 60 °C)

1x 40 A (-25

Maximum current

2x 15 A (-25°C ... 40°C)

2x 26 A (-25°C ... 40°C)

2x 45 A (-25°C ... 40°C)

1x 30 A (-25°C ... 40°C)

1x 52 A (-25°C ... 40°C)

1x 90 A (-25°C ... 40°C)

Transient surge protection

Varistor

Voltage drop, input/output

0.1 V (I

OUT

 = 20 A)

Max. power dissipation (nominal load)

2 W (I

OUT

 = 20 A)

General data

Weight / Dimensions W x H x D

0.4 kg / 32 x 130 x 125 mm

0.6 kg / 38 x 130 x 125 mm

0.9 kg / 66 x 130 x 125 mm

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 14

 

-

 

12

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 10

0.5

Degree of protection / Protection class

IP20 / III

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage: input, output/housing

500 V

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Active redundancy module

QUINT-ORING/24DC/2X10/1X20

2320173

1

260

PHOENIX CONTACT

QUINT ORING

QUINT ORING, 24 V DC

– Preventive function monitoring
– Consistent redundancy up to the load: 

the use of two positive output terminals 
makes it possible to design a redundant 
wiring concept up to the load

– Double the service life of the redundant 

solution thanks to even load distribution: 
the ACB (Auto Current Balancing) 
Technology automatically and 
symmetrically distributes the load current 
to two power supplies operating in 
parallel. 

– Save energy: decoupling is achieved with 

MOSFETs and results in energy savings of 
up to 70%  compared with conventional 
diodes.

– OVP (overvoltage protection): surge 

voltages are limited to 32 V

QUINT ORING, with protective 
coating

With ATEX approval for superior system 

availability under extreme ambient 
conditions, such as dust, dirt, corrosive 
gases, and 100% humidity
– Devices compliant with standards 

EN 60079-15 and EN 60079-0 may be 
installed in a potentially explosive area

– Suitable for use in Class I, Division 2

Power supplies and UPS

Redundancy modules

H

W

D

Active redundancy module, 

with protective coating,

24 V DC, 2 x 10 A, 1 x 20 A

phoenixcontact-protection-html.html
background image

+
+

14

23

24

+

+

I...[A]

-

-
-

IN2

IN1

O

ut

13

3

0

 V A

C/DC

1

00

 

m

A

+
+

14

23

24

+

+

I...[A]

-

-
-

IN2

IN1

O

ut

13

3

0

 V A

C/DC

1

00

 

m

A

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

Ex: 

 

 

 

 

 

 

 

 

 

 

Ex: 

Technical data

Technical data

24 V DC

24 V DC

18 V DC

 

...

 

28 V DC

18 V DC

 

...

 

28 V DC

Nominal current

2x 10 A (-25 °C ... 60 °C)

2x 20 A (-25 °C ... 60 °C)

2x 40 A (-25 °C ... 60 °C)

1x 20 A (-25 °C ... 60 °C)

1x 40 A (-25 °C ... 60 °C)

1x 80 A (-25 °C ... 60 °C)

Maximum current

2x 15 A (-25°C ... 40°C)

2x 26 A (-25°C ... 40°C)

2x 45 A (-25°C ... 40°C)

1x 30 A (-25°C ... 40°C)

1x 52 A (-25°C ... 40°C)

1x 90 A (-25°C ... 40°C)

Varistor

Varistor

0.2 V (I

OUT

 = 40 A)

0.2 V (I

OUT

 = 80 A)

8 W (I

OUT

 = 40 A)

16 W (I

OUT

 = 80 A)

Weight / Dimensions W x H x D

0.4 kg / 32 x 130 x 125 mm

0.6 kg / 38 x 130 x 125 mm

0.9 kg / 66 x 130 x 125 mm

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Screw connection

Screw connection

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 10

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 6

mm² / 10

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 6

0.5

 

-

 

35

 

mm² / 0.5

 

-

 

35

 

mm² / 2

IP20 / III

IP20 / III

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

500 V

500 V

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

QUINT-ORING/24DC/2X20/1X40

2320186

1

QUINT-ORING/24DC/2X40/1X80

2902879

1

261

PHOENIX CONTACT

Power supplies and UPS

Redundancy modules

H

W

D

H

W

D

Active redundancy module, 

with protective coating,

24 V DC, 2 x 20 A, 1 x 40 A

Active redundancy module

24 V DC, 2 x 40 A, 1 x 80 A

phoenixcontact-protection-html.html
background image

+

1

3

14

+

-

I

n

O

ut

3

0 V AC/DC

100 mA

-

A

n

al

og

cont

r

o

l

 

 

 

Ex: 

Technical data

Input data

Nominal input voltage range

12 V DC ... 24 V DC

Input voltage range

8 V DC

 

...

 

30 V DC

Nominal current

40 A (-40 °C ... 60 °C)

Input current I

Stat. Boost 

/ I

Dyn.Boost

 / I

SFB

45 A (40°C) / 60 A (5 s) / 215 A (15 ms)

45 A (40°C) / 60 A (5 s) / 215 A (15 ms)

Transient surge protection

Varistor

Voltage drop, input/output

0.1 V

Max. power dissipation (nominal load)

6 W (I

OUT

 = 40 A)

General data

Weight / Dimensions W x H x D

0.55 kg / 32 x 130 x 125 mm

0.4 kg / 32 x 130 x 125 mm

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Screw connection

Input connection data (solid/stranded/AWG)

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 20

 

-

 

6

0.5

Output connection data (solid/stranded/AWG)

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 20

 

-

 

6

0.5

Degree of protection / Protection class

IP20 / III

Ambient temperature (operation)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

Standards/regulations

Insulation voltage: input, output/housing

500 V

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Active redundancy module

QUINT4-S-ORING/12-24DC/1X40

2907752

1

262

PHOENIX CONTACT

QUINT ORING

QUINT S-ORING, 12 - 24 V DC

– Consistent redundancy: separate cable 

routing up to the load

– Preventive function monitoring
– Save energy: disconnection is 

implemented with MOSFETs and 
therefore has very low power dissipation

– Suitable for use in Class I, Division 2

QUINT S-ORING with ATEX 
approval, protective coating

With protective coating for superior 

system availability under extreme ambient 
conditions, such as dust, dirt, corrosive 
gases, and 100% humidity
– OVP (overvoltage protection): surge 

voltages are limited to 30 V

– Devices compliant with standards 

EN 60079-15 and EN 60079-0 may be 
installed in a potentially explosive area

Power supplies and UPS

Redundancy modules

H

W

D

new

Active redundancy module

12 - 24 V DC, 1 x 40 A

phoenixcontact-protection-html.html
background image

+

1

3

14

+

-

I

n

O

ut

3

0 V AC/DC

100 mA

-

A

n

al

og

cont

r

o

l

OV

P

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

Ex: 

Technical data

12 V DC ... 24 V DC

8 V DC

 

...

 

26 V DC

40 A (-40 °C ... 60 °C)

45 A (40°C) / 60 A (5 s) / 215 A (15 ms)

45 A (40°C) / 60 A (5 s) / 215 A (15 ms)

Varistor

0.1 V

6.5 W (I

OUT

 = 40 A)

Weight / Dimensions W x H x D

0.55 kg / 32 x 130 x 125 mm

0.4 kg / 32 x 130 x 125 mm

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Screw connection

6

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 20

 

-

 

6

6

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 20

 

-

 

6

IP20 / III

Ambient temperature (operation)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

500 V

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Type

Order No.

Pcs./Pkt.

QUINT4-S-ORING/12-24DC/1X40/+

2907753

1

263

PHOENIX CONTACT

Power supplies and UPS

Redundancy modules

H

W

D

new

Active redundancy module, 

with protective coating,

12 - 24 V DC, 1 x 40 A

phoenixcontact-protection-html.html
background image

+

+

+

+

IN

OU

T

-

-

-

-

 

 

Technical data

Input data

Nominal input voltage range

12 V DC ... 24 V DC

12 V DC ... 24 V DC

Input voltage range

10 V DC

 

...

 

30 V DC

10 V DC

 

...

 

30 V DC

Nominal current

2x 20 A (-25 °C ... 60 °C)

2x 20 A (-25 °C ... 60 °C)

1x 40 A (-25 °C ... 60 °C)

1x 40 A (-25 °C ... 60 °C)

Maximum current

2x 30 A (-25°C ... 40°C)

2x 30 A (-25°C ... 40°C)

1x 60 A (-25°C ... 40°C)

1x 60 A (-25°C ... 40°C)

Transient surge protection

Varistor

Voltage drop, input/output

0.5 V

Max. power dissipation (nominal load)

10 W (I

OUT

 = 20 A)

General data

Weight / Dimensions W x H x D

0.75 kg / 50 x 130 x 125 mm

0.75 kg / 50 x 130 x 125 mm

Assembly instructions

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Connection method

Screw connection

Input connection data (solid/stranded/AWG)

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 10

 

-

 

6

0.5

Output connection data (solid/stranded/AWG)

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 10

 

-

 

6

0.5

Degree of protection / Protection class

IP20 / III

Ambient temperature (operation)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

Standards/regulations

Insulation voltage: input, output/housing

500 V

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety, safety transformer

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Diode module

QUINT4-DIODE/12-24DC/2X20/1X40

2907719

1

264

PHOENIX CONTACT

QUINT DIODE diode module

QUINT DIODE, 12 - 24 V DC and 
48 V DC

– Robust design for currents of up to 60 A
– Consistent redundancy up to the load: 

the use of two positive output terminals 
makes it possible to design a redundant 
wiring concept up to the load

– Consistent wiring with large conductor 

cross sections, thanks to same size of 
input and output terminals

– Flexible: nominal voltages of 12 V DC to 

48 V DC

– Devices compliant with standards 

EN 60079-15 and EN 60079-0 may be 
installed in a potentially explosive area

– Suitable for use in Class I, Division 2

Power supplies and UPS

Redundancy modules

H

W

D

new

Diode module,

12 - 24 V DC, 2 x 20 A, 1 x 40 A

phoenixcontact-protection-html.html
background image

+

+

+

+

IN

OU

T

-

-

-

-

For further information and full technical data, visit phoenixcontact.net/products

 

 

Technical data

48 V DC

48 V DC

30 V DC

 

...

 

56 V DC

30 V DC

 

...

 

56 V DC

Nominal current

2x 20 A (-25 °C ... 60 °C)

2x 20 A (-25 °C ... 60 °C)

1x 40 A (-25 °C ... 60 °C)

1x 40 A (-25 °C ... 60 °C)

Maximum current

2x 30 A (-25°C ... 40°C)

2x 30 A (-25°C ... 40°C)

1x 60 A (-25°C ... 40°C)

1x 60 A (-25°C ... 40°C)

Varistor

0.7 V

14 W (I

OUT

 = 20 A)

Weight / Dimensions W x H x D

0.75 kg / 50 x 130 x 125 mm

0.75 kg / 50 x 130 x 125 mm

Alignable: 5 mm horizontally, 15 mm next to active components, 

50 mm vertically

Screw connection

6

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 10

 

-

 

6

6

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 10

 

-

 

6

IP20 / III

Ambient temperature (operation)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

500 V

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety, safety transformer

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Type

Order No.

Pcs./Pkt.

QUINT4-DIODE/48DC/2X20/1X40

2907720

1

265

PHOENIX CONTACT

Power supplies and UPS

Redundancy modules

H

W

D

new

Diode module,

48 V DC, 2x 20 A, 1x 40 A

phoenixcontact-protection-html.html
background image

l

n

1 +

l

n

2

 +

+

+

-

2

x10 A

 

 

Technical data

Input data

Nominal input voltage range

12 V DC ... 24 V DC

Input voltage range

10 V DC

 

...

 

30 V DC

Nominal current

2x 10 A (-25 °C ... 60 °C)

2x 20 A (-25 °C ... 60 °C)

2x 10 A (-25°C ... 55°C)

2x 5 A (-25°C ... 55°C)

1x 20 A (-25 °C ... 60 °C)

1x 40 A (-25 °C ... 60 °C)

1x 20 A (-25°C ... 55°C)

1x 10 A (-25°C ... 55°C)

Maximum current

2x 15 A (-25°C ... 40°C)

2x 25 A (-25°C ... 40°C)

-

-

1x 30 A (-25°C ... 40°C)

1x 50 A (-25°C ... 40°C)

-

-

Transient surge protection

Varistor

Voltage drop, input/output

0.5 V

Max. power dissipation (nominal load)

5 W (I

OUT

 = 10 A)

General data

Weight / Dimensions W x H x D

0.4 kg / 35 x 130 x 115 mm

0.4 kg / 41 x 130 x 115 mm

0.2 kg / 22.5 x 90 x 84 mm

0.1 kg / 18 x 90 x 6

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 m

Connection method

Push-in connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

Degree of protection / Protection class

IP20 / III

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ...

Standards/regulations

Insulation voltage: input, output/housing

500 V

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with

Electrical safety, safety transformer

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

UL/C-UL liste

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Redundancy module

TRIO2-DIODE/12-24DC/2X10/1X20

2907380

1

266

PHOENIX CONTACT

TRIO DIODE, UNO DIODE, and 
STEP DIODE diode modules

TRIO DIODE

– Space-saving: overall width of just 35 mm 

and 41 mm

– Safe decoupling of power supplies 

connected in parallel

– Quick and easy installation, thanks to 

Push-in connection technology

– System compatible with TRIO POWER 

power supplies

UNO DIODE

– Space-saving: overall width of just 

22.5 mm

– Consistent redundancy up to the load: 

the use of two positive output terminals 
makes it possible to design a redundant 
wiring concept up to the load

– Flexible: nominal voltages of 5 V DC to 

24 V DC

STEP DIODE

– Space-saving: overall width of just 18 mm
– Consistent redundancy up to the load: 

the use of two positive output terminals 
makes it possible to design a redundant 
wiring concept up to the load

– Flexible: nominal voltages of 5 V DC to 

24 V DC

Power supplies and UPS

Redundancy modules

H

W

D

new

Diode module,

12 ... 24 V DC, 2 x 10 A, 1 x 20 A

phoenixcontact-protection-html.html
background image

l

n

1 +

l

n

2

 +

+

+

-

2

x

2

0 A

+

OU

T

+

+

+

IN

+

OU

T

+

+

+

IN

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

Technical data

Technical data

Technical data

12 V DC ... 24 V DC

5 V DC ... 24 V DC

5 V DC ... 24 V DC

5 V DC ... 24 V DC

10 V DC

 

...

 

30 V DC

4.5 V DC

 

...

 

30 V DC

4.5 V DC

 

...

 

30 V DC

Nominal current

2x 10 A (-25 °C ... 60 °C)

2x 20 A (-25 °C ... 60 °C)

2x 10 A (-25°C ... 55°C)

2x 5 A (-25°C ... 55°C)

1x 20 A (-25 °C ... 60 °C)

1x 40 A (-25 °C ... 60 °C)

1x 20 A (-25°C ... 55°C)

1x 10 A (-25°C ... 55°C)

Maximum current

2x 15 A (-25°C ... 40°C)

2x 25 A (-25°C ... 40°C)

-

-

1x 30 A (-25°C ... 40°C)

1x 50 A (-25°C ... 40°C)

-

-

Varistor

Varistor

Transil diode

0.5 V

0.5 V

0.5 V

10 W (I

OUT

 = 20 A)

5 W (I

OUT

 = 10 A)

2.5 W (I

OUT

 = 5 A)

Weight / Dimensions W x H x D

0.4 kg / 35 x 130 x 115 mm

0.4 kg / 41 x 130 x 115 mm

0.2 kg / 22.5 x 90 x 84 mm

0.1 kg / 18 x 90 x 61 mm

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Alignable: 0 mm horizontally, 30 mm vertically

Push-in connection

Screw connection

Screw connection

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / III

IP20 / III

IP20 / III

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 55 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

500 V

500 V

500 V

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety, safety transformer

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

TRIO2-DIODE/12-24DC/2X20/1X40

2907379

1

UNO-DIODE/5-24DC/2X10/1X20

2905489

1

STEP-DIODE/5-24DC/2X5/1X10

2868606

1

267

PHOENIX CONTACT

Power supplies and UPS

Redundancy modules

H

W

D

new

H

W

D

H

W

D

Diode module,

12 ... 24 V DC, 2 x 20 A, 1 x 40 A

Diode module,

5 ... 24 V DC, 2 x 10 A, 1 x 20 A  

Diode module

5 - 24 V DC, 2x 5 A, 1x 10 A

phoenixcontact-protection-html.html
background image

Technical data

Technical data

Dimensions W x H x D

74 / 130 / 11 mm

104 / 130 / 11 mm

Material

Aluminum

Aluminum

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Adapter for S7-300 rail mounting

, for:

QUINT-PS/1AC/24DC/3.5

QUINT-PS/1AC/24DC/5

QUINT-PS/3AC/24DC/5

QUINT-PS-ADAPTERS7/1

2938196

1

Adapter for S7-300 rail mounting

, for:

QUINT-PS/1AC/24DC/10

QUINT-PS/3AC/24DC/10

QUINT-PS/3AC/24DC/20

QUINT-PS-ADAPTERS7/2

2938206

1

To supply a SIMATIC

®

 S7-300 controller, 

QUINT POWER 2.5 A, 5 A, and 10 A are 
mounted on the S7 rail using a QUINT-PS-
ADAPTER-S7.

No further accessories are required for 

fastening.

Mounting on S7-300 rail

Power supplies and UPS

Accessories for power supplies

D W

H

Technical data

Technical data

Dimensions W x H x D

41 / 27 / 42.2 mm

50 / 65.5 / 50 mm

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Fan

 for QUINT POWER SFB, 24 V DC

QUINT-PS/FAN/4

2320076

1

VARIOFACE module

, with two busbars (P1, P2) for potential 

distribution, per potential:

2 power terminal blocks/8 distributor terminal blocks

VIP-2/SC/PDM-2/16

2315256

1

2 power terminal blocks/12 distributor terminal blocks

VIP-2/SC/PDM-2/24

2315269

1

2 power terminal blocks/16 distributor terminal blocks

VIP-2/SC/PDM-2/32

2315272

1

2 power terminal blocks/24 distributor terminal blocks

VIP-2/SC/PDM-2/48

1

)

2903717

1

268

PHOENIX CONTACT

With the standard power supply mounting 

position, the temperature range increases by 
10 K (max. ambient temperature of 70°C), 
when the mounting position is rotated, 
position-dependent derating no longer 
applies.
– Tool-free mounting

Potential distributor

Further modules can be found in Catalog 

5, interface technology and switching devices

Fan and potential distributor

With screw connection and 2 potential levels

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Dimensions W x H x D

52 / 182 / 9 mm

25 / 130 / 17 mm

Material

Steel, powder-coated

Steel, powder-coated

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Universal wall adapter

, for direct wall mounting of the TRIO-PS 

(from 10 A), QUINT-PS, QUINT-DC-UPS, QUINT-BUFFER power 

supplies

UWA 182/52

2938235

1

Universal wall adapter

, for direct wall mounting of the QUINT-

PS/1AC/24DC/40 and QUINT-UPS/1AC/1AC/500VA power 

supplies

UWA 130

2901664

1

Adapter for mounting on even surfaces

Universal wall adapter

Power supplies and UPS

Accessories for power supplies

Technical data

Dimensions W/H/D

12.3 mm / 90 mm / 77.3 mm

Degree of protection

IP30 (Actuation area)

Ordering data

Description

Nominal

current

Type

Order No.

Pcs./Pkt.

Thermomagnetic circuit breaker,

 plug-in, 1-pos., signal contact 

1 PDT

0.5 A

CB TM1 0.5A SFB P

2800835

1

1 A

CB TM1 1A SFB P

2800836

1

2 A

CB TM1 2A SFB P

2800837

1

3 A

CB TM1 3A SFB P

2800838

1

4 A

CB TM1 4A SFB P

2800839

1

5 A

CB TM1 5A SFB P

2800840

1

6 A

CB TM1 6A SFB P

2800841

1

Accessories

Base element, 

for accommodating CB TM.../CB E... device circuit 

breakers

With Push-in connection technology

CB 1/6-2/4 PT-BE

2800929

10

With screw connection technology

CB 1/10-1/10 UT-BE

2801305

10

269

PHOENIX CONTACT

Notes:

For additional technical data, drawings, and accessories, please 

visit phoenixcontact.net/products.

– Device circuit breakers for protecting 

against overcurrents and short circuits

– SFB characteristic curve enables longer 

cables and tripping times of < 10 ms

– Maximum ease of maintenance thanks to 

the two-piece design

– Further circuit breakers can be found on 

page 307 onwards

Plug-in thermomagnetic circuit 
breakers

Can be plugged in, SFB characteristic curve

phoenixcontact-protection-html.html
background image

270

PHOENIX CONTACT

Power supplies and UPS

Uninterruptible power supplies

The intelligent UPS system ensures 
superior system availability

Uninterruptible power supplies (UPS) 

continue to deliver power even if the supply 
network goes down. An uninterruptible 
solution consists of the three function units 
shown:
– Power supply
– UPS module
– Energy storage

QUINT UPS

IQ technology is the key to an intelligent 

power supply solution. The uninterruptible 
power supply monitors and optimizes the 
energy storage. Avoid interruptions when 
working with the intelligent UPS for non-
stop power.
– You know the state of charge and 

remaining runtime of your energy storage

– You are warned about failures at an early 

stage and have time to prevent them

– You can maximize the service life of the 

energy storage

– You can transfer all relevant information 

to your computer and higher-level 
controllers

Practical example

An industrial PC must be continuously 

supplied with 24 V DC.

Previous solution:

The UPS with 3.4 Ah energy 

storage buffers 24 V DC / 5 A for 
20 minutes under optimum conditions.

Can the energy storage actually bridge 

this time?

The state of charge, performance, and 

remaining runtime of the energy storage are 
unknown.

Solution with QUINT UPS:

The intelligent UPS determines all 

relevant energy storage states. This ensures 
the crucial transparency required to 
guarantee the stability of the supply and 
optimum use of the energy storage at all 
times.

The intelligent battery management 

detects the current state of charge of the 
connected energy storage and uses this to 
calculate the remaining runtime.

The QUINT UPS also indicates whether 

the buffer time is actually 20 minutes. As 
soon as an adjustable threshold value is 
reached, a warning message is sent via the 
floating relay contact, the software or 
directly to higher-level controllers. The IPC 
continues working for as long as possible 
and is shut down before the battery voltage 
runs out.

Space-saving versions

To save space in the control cabinet or to 

retrofit existing systems easily, UPS versions 
with integrated energy storage or 
integrated power supply are recommended.

Selection guide

Find the right UPS for your application 

based on the buffer time and load current. 
Please refer to the color selection tables on 
pages:
–  272
–  278
–  292

Your web code: 

#0154

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

271

PHOENIX CONTACT

Power supplies and UPS

Uninterruptible power supplies

IQ technology

The IQ technology is intuitive and 

provides you with information as soon as it 
is required.
– Intelligent battery management with SOC 

(state of charge), detects the current 
state of charge and the remaining 
runtime, and SOH (state of health), 
determines the remaining life expectancy 
of the energy storage and warns of failure 
at an early stage

– Intelligent battery control
– Intelligent charging

Signaling and configuration

The UPS-CONF configuration and 

management software allows you to 
monitor and configure your UPS system. 
The software can be downloaded free of 
charge at: phoenixcontact.net/products.
– Flexible adaptation of QUINT UPS 

behavior to individual requirements

– Monitoring and data recorder

Communication

The data cables allow you to integrate the 

UPS module into your application. You can 
therefore benefit from all the advantages of 
IQ technology and be kept informed of the 
state of your UPS solution. The information 
provided by QUINT UPS can, for example, 
be forwarded to higher-level controllers via 
Ethernet or be implemented directly in 
control solutions from Phoenix Contact.

AC UPS

The AC UPS delivers a pure sine curve at 

the output. The sine generated in battery 
operation is synchronous with the mains 
previously used for supply.

QUINT UPS with IQ technology

– Optimum use of the buffer time (SOC) 

and preventive monitoring of the energy 
storage (SOH)

TRIO AC UPS

– Space-saving, as the UPS module and 

energy storage are combined in one 
housing

UPS with integrated energy storage

Particularly space-saving and easy to 

retrofit, the UPS module and energy storage 
are combined in the same housing.
– QUINT UPS: energy storage with lead 

AGM technology

– STEP UPS: LiPo-based energy storage
– UNO UPS: energy storage with lead AGM 

technology

– QUINT BUFFER buffer module and 

QUINT CAP: capacitor-based energy 
storage

UPS with integrated power supply

The UPS module and power supply in a 

single housing is a space-saving solution. 
Only one energy storage is required to 
complete the UPS system. 
– MINI UPS: for 24 or 12 V DC
– TRIO UPS: for 24 DC

phoenixcontact-protection-html.html
background image

272

PHOENIX CONTACT

Selecting the energy storage for QUINT DC-UPS

You can always find the ideal solution for 

superior system availability with the new 
modular system for uninterruptible power 
supplies. The various storage media feature 
a wide range of different properties: long 
service life or very long buffer time, no 
maintenance or use at extreme ambient 
temperatures. Whatever your 
requirements, we offer the ideal energy 
storage.

Type

Buffer time

Typical

Temperature

Service life

at +20°C

Service life

at +50°C

Charging cycles

at +20°C

Weight

(standardized)

UPS-CAP…

< 5 min

-40 to 60°C

> 20 years

8 years

> 500,000

0.4 kg

UPS-BAT/LI-ION…

> 40 min

-20 to 60°C

15 years

2 years

7,000

0.45 kg

UPS-BAT/VRLA-WTR…

> 5 h

-25 to 60°C

12 years

1.5 years

300

1.3 kg

UPS-BAT/VRLA…

> 8 h

0 to 40°C

6 to 9 years

1 year

250

1 kg

UPS-BAT/LI-ION...

Long service life with long 
buffer times

Low  weight

Lithium iron phosphate 
technology

UPS-BAT/VRLA-WTR...
(Valve Regulated Lead Acid/
Wide Temperature Range)

Maximum buffer times at extreme temperatures

Pure lead AGM (Absorbent Glass Mat) technology

UPS-CAP (Capacitor)

Maximum service life

Maintenance-free double layer ca-
pacitors

UPS-BAT/VRLA...
(Valve Regulated Lead Acid)

Maximum buffer times

Lead AGM (Absorbent Glass Mat) 
technology

Your advantages

Fast installation
– Automatic detection of the energy 

storage by QUINT UPS

– Tool-free replacement during operation

Maximum availability
– Constant communication with 

QUINT UPS for continuous monitoring 
and intelligent management

Extremely long service life
– Optimum charging characteristic 

according to the technology and ambient 
conditions

Power supplies and UPS

Uninterruptible power supplies

phoenixcontact-protection-html.html
background image

1+1 1+1

1+1 1+1

1+1 1+1

1+1 1+1

1+1 1+1

1+1 1+1

1+1

1+1 1+1

1+1 1+1 1+1

1+1 1+1 1+1 1+1

1+1 1+1 1+1 1+1

1+1 1+1

1+1 1+1

1+1 1+1

1+1 1+1

1+1 1+1 1+1

1+1 1+1

1+1

1+1 1+1

1+1 1+1 1+1

1+1 1+1 1+1 1+1

1+1 1+1 1+1 1+1

For further information and full technical data, visit phoenixcontact.net/products

273

PHOENIX CONTACT

Buffer times of energy storage devices with double-layer capacitors and lithium 
iron phosphate and pure lead AGM technology with a large temperature range

Select your 

UPS-BAT

 and 

UPS-CAP

 

for 24 V DC applications here.

Example: 20 A needs to be buffered for 

6 minutes.

Solution: 
UPS-BAT/LI-ION/24DC/120WH

1+1 … Two energy storage devices of the same capacity are 

required in this case.

The data is based on an ambient temperature of +20°C.

Buffer times of energy storage devices 
with lead AGM technology

Select your UPS-BAT for 24 V DC 

applications here.

Example: 20 A needs to be buffered for 

10 minutes.

Solution: 
UPS-BAT/VRLA/24DC/12AH

Buffer times for QUINT DC-UPS

Buffer time

Seconds

Minutes

Hours

10

15

30

1

2

3

5

6

7

8

9

10

20

30

40

45

50

1

2

3

5

8

10

15

20

Lo

a

d

 c

u

r

r

e

n

t

1 A

2 A

3 A

5 A

7 A

10 A

15 A

20 A

25 A

30 A

35 A

40 A

Energy storage

UPS-BAT/VRLA/24DC/1.3AH

UPS-BAT/VRLA/24DC/12AH

UPS-BAT/VRLA/24DC/3.4AH

UPS-BAT/VRLA/24DC/38AH

UPS-BAT/VRLA/24DC/7.2AH

Buffer time

Seconds

Minutes

Hours

10

15

30

1

2

3

5

6

7

8

9

10

20

30

40

45

50

1

2

3

5

8

10

15

20

Loa

d

 c

u

r

r

e

n

t

1 A

2 A

3 A

5 A

7 A

10 A

15 A

20 A

25 A

30 A

35 A

40 A

Energy storage

UPS-CAP/24DC/10A/10KJ

UPS-CAP/24DC/20A/20KJ

UPS-BAT/VRLA-WTR/24DC/13AH

UPS-BAT/VRLA-WTR/24DC/26AH

UPS-BAT/LI-ION/24DC/120WH

UPS-BAT/LI-ION/24DC/924WH

1+1 … Two energy storage devices of the same capacity are 

required in this case.

The data is based on an ambient temperature of +20°C.

Power supplies and UPS

Uninterruptible power supplies

phoenixcontact-protection-html.html
background image

13

23

33

14

24

34

R

1

R

2

A

larm

Ba

t.-

Mode

Ba

t.-

C

h

ar

ge

R

e

m

ote

Ba

tte

r

y

C

onfi

rm

Da

t

a

-Po

r

t

Input

DC

 24V

O

utput

DC

 24V

24V 

0

.2A

I  < I

N

m

C

J

t

[

m

in]

max

24V

DC

J

 

 

 

 DNV GL 

Ex: 

Technical data

Input data

Nominal input voltage range

24 V DC

Input voltage range

18 V DC

 

...

 

30 V DC

Max. current consumption

9.4 A (Maximum, mains operation)

19 A (M

Output data (mains operation)

Nominal output voltage

24 V DC

Output voltage range

18 V DC ... 30 V DC

Degree of efficiency

> 98 % (Mains operation, with charged energy storage)

> 98 % (Mains operation, with charged energy storage)

>

Output current with convection cooling

- Nominal output current I

N

 (continual)

5 A (-25 °C ... 60 °C)

- SFB Technology (12 ms)

30 A (-25 °C ... 60 °C)

- Power

 

Boost I

Boost

 (continual)

7.5 A (-25°C ... 40°C)

Output data (battery operation)

Nominal output voltage

24 V DC

Output voltage range

19.2 V DC ... 27.6 V DC (U

OUT

 = U

BAT

 - 0.5 V DC)

19.2 V DC ... 27.6 V DC (U

Output current with convection cooling

- SFB Technology (15 ms)

32.5 A (-25 °C ... 60 °C)

65 A (-25 °C ... 60 °C)

120 A (-25 °C ... 60 °C)

215 A (-25 °C ... 60 °C)

- Power

 

Boost I

Boost

 (continual)

7.5 A (-25°C ... 40°C)

Energy storage

Nominal voltage U

N

24 V DC

End-of-charge voltage

24 V DC ... 29 V DC (temperature compensated)

24 V DC ... 29 V DC (temperature compensated)

24 V DC ... 29 V

Nominal capacity range

0.8 Ah ... 140 Ah

Max. charging current

0.2 A ... 1.36 A

Signaling

Signaling

LED, relay contact, interface/software

LED, relay contact, interface/software

LED, relay contact, interface/software

LED,

Interfaces

IFS (Interface system data port)

IFS (Interface system data port)

IFS (Interface system data port)

IFS (Interface system

General data

Weight / Dimensions W x H x D

0.5 kg / 35 x 130 x 125 mm

0.5 kg / 35 x 130 x 125 mm

0.6 kg / 40 x 130 x 125 mm

0.7 kg / 47 x 130 x 

Connection method

Plug-in screw connection

Plug-in screw connection

Screw connection

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 20

 

-

 

12

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 20

 

-

 

12

0.2

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

Degree of protection / Protection class

IP20 / III

Ambient temperature (operation)

-25 °C ... 70 °C

Ambient temperature (storage/transport)

-40 °C ... 85 °C

Derating

60 °C ... 70 °C (2.5%/K)

60 °C ... 70 °C (2.5

Max. permissible relative humidity (operation)

 95 % (25°C, non-condensing)

Standards/regulations

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply

, uninterruptible

QUINT-UPS/24DC/24DC/5

2320212

1

274

PHOENIX CONTACT

QUINT UPS for DC applications

The UPS module for 24 V DC with output 

currents ranging from 5 to 40 A allows you 
to create a custom solution combining 
power supply, UPS module, and energy 
storage.

Optimum use of the buffer time and 

preventive monitoring of the energy 
storage:
– Detects the current state of charge of the 

energy storage and calculates the 
remaining runtime

– Calculates the current life expectancy of 

the energy storage

Substantial power reserve:

– For mains and battery operation
– Power Boost static power reserve
– Dynamic power reserve with SFB 

(Selective Fuse Breaking) Technology

Fast battery charging:

– Adaptive current management charges 

the energy storage twice as fast as before, 
while simultaneously providing sufficient 
energy for the loads.

Extensive signaling and parameterization:

– Floating relay contacts
– Data port
– Parameterization with memory module

Power supplies and UPS

Uninterruptible power supplies

H

W

D

Notes:

The buffer time associated with your solution is dependent on the 

load current. Exact details for each uninterruptible power supply 

can be found on page 273.

Uninterruptible power supply,

24 V DC / 24 V DC, 5 A

phoenixcontact-protection-html.html
background image

13

23

33

14

24

34

R

1

R

2

A

larm

Ba

t.-

Mode

Ba

t.-

C

h

ar

ge

R

e

m

ote

Ba

tte

r

y

C

onfi

rm

Da

t

a

-Po

r

t

Input

DC

 24V

O

utput

DC

 24V

24V 

0

.2A

I  < I

N

m

C

J

t

[

m

in]

max

24V

DC

J

13

23

33

14

24

34

R

1

R

2

A

larm

Ba

t.-

Mode

Ba

t.-

C

h

ar

ge

R

e

m

ote

Ba

tte

r

y

C

onfi

rm

Da

t

a

-Po

r

t

Input

DC

 24V

O

utput

DC

 24V

24V 

0

.2A

I  < I

N

m

C

J

t

[

m

in]

max

24V

DC

J

13

23

33

14

24

34

R

1

R

2

A

larm

Ba

t.-

Mode

Ba

t.-

C

h

ar

ge

R

e

m

ote

Ba

tte

r

y

C

onfi

rm

Da

t

a

-Po

r

t

Input

DC

 24V

O

utput

DC

 24V

24V 

0

.2A

I  < I

N

m

C

J

t

[

m

in]

max

24V

DC

J

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 DNV GL 

Ex: 

 

 

 

 DNV GL 

Ex: 

 

 

 

 DNV GL 

Ex: 

Technical data

Technical data

Technical data

24 V DC

24 V DC

24 V DC

18 V DC

 

...

 

30 V DC

18 V DC

 

...

 

30 V DC

18 V DC

 

...

 

30 V DC

Max. current consumption

9.4 A (Maximum, mains operation)

19 A (Maximum, mains operation)

32.9 A (Maximum, mains operation)

51.9 A (Maximum, mains operation)

24 V DC

24 V DC

24 V DC

18 V DC ... 30 V DC

18 V DC ... 30 V DC

18 V DC ... 30 V DC

Degree of efficiency

> 98 % (Mains operation, with charged energy storage)

> 98 % (Mains operation, with charged energy storage)

> 98 % (Mains operation, with charged energy storage)

> 99 % (Mains operation, with charged energy storage)

10 A (-25 °C ... 60 °C)

20 A (-25 °C ... 60 °C)

40 A (-25 °C ... 50 °C)

60 A (-25 °C ... 60 °C)

120 A (-25 °C ... 60 °C)

215 A (-25 °C ... 60 °C)

15 A (-25°C ... 40°C)

26 A (-25°C ... 40°C)

45 A (-25°C ... 40°C)

24 V DC

24 V DC

24 V DC

 - 0.5 V DC)

19.2 V DC ... 27.6 V DC (U

OUT

 = U

BAT

 - 0.5 V DC)

19.2 V DC ... 27.6 V DC (U

OUT

 = U

BAT

 - 0.5 V DC)

19.2 V DC ... 27.6 V DC (U

OUT

 = U

BAT

 - 0.5 V DC)

- SFB Technology (15 ms)

32.5 A (-25 °C ... 60 °C)

65 A (-25 °C ... 60 °C)

120 A (-25 °C ... 60 °C)

215 A (-25 °C ... 60 °C)

15 A (-25°C ... 40°C)

27 A (-25°C ... 40°C)

45 A (-25°C ... 40°C)

24 V DC

24 V DC

24 V DC

End-of-charge voltage

24 V DC ... 29 V DC (temperature compensated)

24 V DC ... 29 V DC (temperature compensated)

24 V DC ... 29 V DC (temperature compensated)

24 V DC ... 29 V DC (temperature compensated)

1.3 Ah ... 140 Ah

3 Ah ... 200 Ah

7 Ah ... 200 Ah

0.2 A ... 2.88 A

0.2 A ... 5 A

0.2 A ... 5 A

Signaling

LED, relay contact, interface/software

LED, relay contact, interface/software

LED, relay contact, interface/software

LED, relay contact, interface/software

Interfaces

IFS (Interface system data port)

IFS (Interface system data port)

IFS (Interface system data port)

IFS (Interface system data port)

Weight / Dimensions W x H x D

0.5 kg / 35 x 130 x 125 mm

0.5 kg / 35 x 130 x 125 mm

0.6 kg / 40 x 130 x 125 mm

0.7 kg / 47 x 130 x 125 mm

Connection method

Plug-in screw connection

Plug-in screw connection

Screw connection

Screw connection

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 12

 

-

 

10

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 8

 

-

 

6

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 12

 

-

 

10

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 8

 

-

 

6

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

IP20 / III

IP20 / III

IP20 / III

-25 °C ... 70 °C

-25 °C ... 70 °C

-25 °C ... 70 °C

-40 °C ... 85 °C

-40 °C ... 85 °C

-40 °C ... 85 °C

Derating

60 °C ... 70 °C (2.5%/K)

60 °C ... 70 °C (2.5%/K)

60 °C ... 70 °C (2.5%/K)

60 °C ... 70 °C (2.5%/K)

 95 % (25°C, non-condensing)

 95 % (25°C, non-condensing)

 95 % (25°C, non-condensing)

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

QUINT-UPS/ 24DC/ 24DC/10

2320225

1

QUINT-UPS/ 24DC/ 24DC/20

2320238

1

QUINT-UPS/ 24DC/ 24DC/40

2320241

1

275

PHOENIX CONTACT

Power supplies and UPS

Uninterruptible power supplies

H

W

D

H

W

D

H

W

D

Uninterruptible power supply,

24 V DC / 24 V DC, 10 A

Uninterruptible power supply,

24 V DC / 24 V DC, 20 A

Uninterruptible power supply,

24 V DC / 24 V DC, 40 A

phoenixcontact-protection-html.html
background image

13

23

33

14

24

34

R

1

R

2

A

larm

Ba

t.-

Mode

Ba

t.-

C

h

ar

ge

R

e

m

ote

Ba

tte

r

y

C

onfi

rm

Da

t

a

-Po

r

t

Input

DC

 24V

O

utput

DC

 24V

O

utput

DC

 12V

24V 

0

.2A

I  < I

N

m

C

J

t

[

m

in]

max

24V

DC

 

 

Technical data

Input data

Input voltage

24 V DC

Input voltage range

18 V DC ... 30 V DC

Max. current consumption

16 A

Output data (mains operation)

12 V DC

24 V DC

Nominal output voltage

12 V DC

24 V DC

Output voltage range

18 V DC ... 30 V DC 

(U

OUT

 = U

IN

 - 0.5 V DC)

Efficiency (typ.)

> 93 % (Mains operation, with 

charged energy storage)

> 98 % (Mains operation, with 

charged energy storage)

Output current with convection cooling 

(P

max

 = P

12 V

 + P

24 V

 = 360 W)

- Nominal output current I

N

 (continual)

5 A (-25 °C ... 60 °C)

10 A (-25 °C ... 60 °C)

- SFB Technology (15 ms)

-

60 A (-25 °C ... 60 °C)

- Power

 

Boost I

Boost

 (continual)

7.5 A (-25°C ... 40°C)

15 A (-25°C ... 40°C)

Output data (battery operation)

12 V DC

24 V DC

Nominal output voltage

12 V DC

24 V DC

Output voltage range

-

19.2 V DC ... 27.6 V DC 

(U

OUT

 = U

BAT

 - 0.5 V DC)

Output current with convection cooling 

(P

max

 = P

12 V

 + P

24 V

 = 360 W)

- Nominal output current I

N

 (continual)

5 A (-25 °C ... 60 °C)

10 A (-25 °C ... 60 °C)

- SFB Technology (15 ms)

-

65 A (-25 °C ... 60 °C)

- Power

 

Boost I

Boost

 (continual)

7.5 A (-25°C ... 40°C)

15 A (-25°C ... 40°C)

Energy storage

Nominal voltage U

N

24 V DC

End-of-charge voltage

24 V DC ... 29 V DC (temperature compensated)

Nominal capacity range

1.3 Ah ... 140 Ah

Max. charging current

0.2 A ... 2.88 A

Signaling

Signaling

LED, relay contact, interface/software

Interfaces

IFS (Interface system data port)

General data

Weight / Dimensions W x H x D

0.6 kg / 35 x 130 x 125 mm

Connection method

Plug-in screw connection

Connection data input/output solid/stranded/AWG

0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12

Signal connection data (solid/stranded/AWG)

0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12

Degree of protection / Protection class

IP20 / III

Ambient temperature (operation)

-25 °C ... 70 °C

Derating

60 °C ... 70 °C (2.5%/K)

Standards/regulations

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply

, uninterruptible

QUINT-UPS/ 24DC/12DC/5/24DC/10

2320461

1

276

PHOENIX CONTACT

Notes:

The buffer time associated with your solution is dependent on the 

load current. Exact details for each uninterruptible power supply 

can be found on page 273.

H

W

D

The UPS module for two output voltages, 

12 and 24 V DC, allows you to create a 
custom solution combining power supply, 
UPS module, and energy storage.
– Flexible and space-saving thanks to the 

two output voltages in one unit

Optimum use of the buffer time and 

preventive monitoring of the energy 
storage:
– Detects the current state of charge of the 

energy storage and calculates the 
remaining runtime

– Calculates the current life expectancy of 

the energy storage

Substantial power reserve:

– For mains and battery operation
– Power Boost static power reserve
– Dynamic power reserve with SFB 

(Selective Fuse Breaking) Technology

Fast battery charging:

– Adaptive current management charges 

the energy storage twice as fast as before, 
while simultaneously providing sufficient 
energy for the loads.

Extensive signaling and parameterization:

– Floating relay contacts
– Data port
– Parameterization with memory module

QUINT UPS for DC applications with 
dual output voltage

Power supplies and UPS

Uninterruptible power supplies

Uninterruptible power supply,

24 V DC/12 V DC, 5 A and 24 V DC, 10 A

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

277

PHOENIX CONTACT

Power supplies and UPS

Uninterruptible power supplies

phoenixcontact-protection-html.html
background image

1+1

1+1 1+1

1+1 1+1

1+1 1+1

1+1 1+1 1+1

1+1 1+1

1+1 1+1

1+1 1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

278

PHOENIX CONTACT

Selecting the energy storage for AC-UPS

You can always find the ideal solution for 

superior system availability with the new 
modular system for uninterruptible power 
supplies. The various storage media feature 
a wide range of different properties: long 
service life or very long buffer time, no 
maintenance or use at extreme ambient 
temperatures. Whatever your 
requirements, we offer the ideal energy 
storage.

Type

Buffer time

Typical

Temperature

Service life

at +20°C

Service life

at +50°C

Charging cycles

at +20°C

Weight

(standardized)

UPS-CAP…

< 5 min

-40 to 60°C

> 20 years

8 years

> 500,000

0.4 kg

UPS-BAT/LI-ION…

> 40 min

-20 to 60°C

15 years

2 years

7,000

0.45 kg

UPS-BAT/VRLA-WTR…

> 5 h

-25 to 60°C

12 years

1.5 years

300

1.3 kg

UPS-BAT/VRLA…

> 8 h

0 to 40°C

6 to 9 years

1 year

250

1 kg

Your advantages

Fast installation
– Automatic detection of the energy 

storage by QUINT UPS

– Tool-free replacement during operation

Maximum availability
– Constant communication with 

QUINT UPS for continuous monitoring 
and intelligent management

Extremely long service life
– Optimum charging characteristic 

according to the technology and ambient 
conditions

Buffer times of energy storage devices with double-layer capacitors and lithium 
iron phosphate and pure lead AGM technology with a large temperature range

Select the 

UPS-BAT

 and 

UPS-CAP

 for 

your QUINT AC-UPS / 500 VA 
(120/230 V AC applications) here.

Example: 125 W needs to be buffered for 

one hour.

Solution: 
UPS-BAT/VRLA-WTR/24DC/26AH

Buffer times for QUINT AC-UPS

Buffer time

Seconds

Minutes

Hours

0.2

0.4

2

8

15

20

40

1

2

3

5

10

20

30

40

45

50

1

2

3

5

8

10

15

20

Po

w

e

r

15 W

35 W

55 W

90 W

125 W

180 W

275 W

400 W

Energy storage

UPS-CAP/24DC/20A/20KJ

UPS-BAT/VRLA-WTR/24DC/13AH

UPS-BAT/VRLA-WTR/24DC/26AH

UPS-BAT/LI-ION/24DC/120WH

UPS-BAT/LI-ION/24DC/924WH

1+1 … Two energy storage devices of the same capacity are 

required in this case.

The data is based on an ambient temperature of +20°C.

Select the 

UPS-BAT

 for your QUINT 

AC-UPS / 1000 VA (120/230 V AC 
applications) here.

Example: 400 W needs to be buffered for 

three hours.

Solution: 
2x UPS-BAT/LI-ION/24DC/924WH

Buffer time

Minutes

Hours

2

3

4

5

8

10

15

20

25

30

40

50

1

1.5

2

3

4

6

9

10

Po

w

e

r

100 W

200 W

300 W

400 W

500 W

600 W

700 W

800 W

900 W

Energy storage

UPS-BAT/VRLA-WTR/24DC/13AH

UPS-BAT/VRLA-WTR/24DC/26AH

UPS-BAT/LI-ION/24DC/120WH

UPS-BAT/LI-ION/24DC/924WH

Power supplies and UPS

Uninterruptible power supplies

phoenixcontact-protection-html.html
background image

1+1

1+1

1+1

1+1

1+1 1+1

1+1

1+1 1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1+1

For further information and full technical data, visit phoenixcontact.net/products

279

PHOENIX CONTACT

1+1 … An additional energy storage device of the same capacity 

(3.4 AH) of type 

UPS-BAT/VRLA/24DC/3.4AH (

2320306

) or QUINT-

BAT/24DC/3.4AH (

2866349

) is required in this case.

The data is based on an ambient temperature of +20°C.

Buffer times of energy storage devices with lead AGM technology

Select the 

UPS-BAT/VRLA

 for your 

QUINT AC-UPS / 500 VA (120/230 V AC 
applications) here.

Example: 125 W needs to be buffered for 

one hour.

Solution: 
UPS-BAT/VRLA/24DC/12AH

Buffer times for QUINT AC-UPS

Buffer time

Seconds

Minutes

Hours

0.2

0.4

2

8

15

20

40

1

2

3

5

10

20

30

40

45

50

1

2

3

5

8

10

15

20

Po

w

e

r

15 W

35 W

55 W

90 W

125 W

180 W

275 W

400 W

Energy storage

UPS-BAT/VRLA/24DC/3.4AH

UPS-BAT/VRLA/24DC/12AH

UPS-BAT/VRLA/24DC/7.2AH

UPS-BAT/VRLA-WTR/24DC/38AH

Buffer times for TRIO AC-UPS with 
integrated energy storage

Buffer time

Minutes

Hours

1

1.5

2

4

6

8

10

15

20

30

40

50

1

1.5

Po

w

e

r

50 W

100 W

150 W

200 W

250 W

300 W

400 W

500 W

600 W

1+1 … Two energy storage devices of the same capacity are 

required in this case.

The data is based on an ambient temperature of +20°C.

Buffer time

Minutes

Hours

2

3

4

5

8

10

15

20

25

30

40

50

1

1.5

2

3

4

6

9

10

Po

w

e

r

100 W

200 W

300 W

400 W

500 W

600 W

700 W

800 W

900 W

Energy storage

UPS-BAT/VRLA/24DC/3.4AH

UPS-BAT/VRLA/24DC/12AH

UPS-BAT/VRLA/24DC/7.2AH

UPS-BAT/VRLA-WTR/24DC/38AH

Select the 

UPS-BAT/VRLA

 for your 

QUINT AC-UPS / 1000 VA (120/230 V AC 
applications) here.

Example: 400 A needs to be buffered for 

30 minutes.

Solution: 
2x UPS-BAT/VRLA/24DC/12AH

Power supplies and UPS

Uninterruptible power supplies

phoenixcontact-protection-html.html
background image

R

1

G

N

D

R

2

t

[

m

in]

max

A

larm

Ba

t.-Mode

Powe

r

-

B

oost

R

e

m

ote

Ba

tte

r

y

C

onfi

rm

Da

t

a

-Po

r

t

USB

-Po

r

t

Input A

C

1

00

..24

0

V

O

utput A

C

12

0/

23

0

V

Autono

m

ic-

S

t

ar

t

24V

0

.

0

3A

12

0

V2

3

0

V

m

C

J

I

F

S

24V

DC

L

L

N

N

PE

PE

 

Ex: 

Technical data

General input data

Input voltage range

180 V AC ... 264 V AC

Frequency range

45 Hz ... 65 Hz

Activation threshold

U

N

 ±10 %. Can be configured using UPS-CONF software.

Can be configured using UPS-CONF software

Input data

120 V

 

AC

230 V AC

Nominal input voltage

120 V AC

230 V AC

120 V AC

230 V AC

Input voltage range AC

102 V AC ... 138 V AC

196 V AC ... 264 V AC

96 V AC ... 144 V AC

184 V AC ... 264 V AC

Nominal frequency

50 Hz ... 60 Hz

50 Hz ... 60 Hz

60 Hz

50 Hz

Max. current consumption (I

IN

 = I

CHARGE

 + I

BOOST

)

6.8 A

3.7 A

13 A

7 A

General output data

Nominal power / Apparent power

400 W / 500 VA

Derating

> 50 °C ... 70 °C (2.5%/K)

Switch-over time

< 10 ms

Efficiency (typ.)

> 98 % (Mains operation)

> 92 % (with charged energy storage)

Output data (mains operation)

120 V

 

AC

230 V AC

Nominal output voltage

120 V AC

230 V AC

120 V AC

230 V AC

Output voltage range

102 V AC ... 138 V AC

196 V AC ... 264 V AC

- Nominal output current I

N

 (continual)

4.3 A ( -25 °C ... 70 °C )

2.2 A ( -25 °C ... 70 °C )

8.3 A ( -25 °C ... 70 °C )

4.4 A ( -25 °C ... 70 °C )

- Power

 

Boost I

Boost

 (continual)

5.2 A ( -25 °C ... 70 °C )

2.7 A ( -25 °C ... 70 °C )

13 A ( -25 °C ... 70 °C )

7 A ( -25 °C ... 70 °C )

Output data (battery operation)

120 V

 

AC

230 V AC

Nominal output voltage

120 V AC

230 V AC

120 V AC

230 V AC

- Nominal output current I

N

 (continual)

4.3 A ( -25 °C ... 50 °C )

2.2 A ( -25 °C ... 50 °C )

8.3 A ( -25 °C ... 70 °C )

4.4 A ( -25 °C ... 70 °C )

- Power

 

Boost I

Boost

 (5 s)

5.2 A ( -25 °C ... 50 °C )

2.7 A ( -25 °C ... 50 °C )

13 A ( -25 °C ... 70 °C )

7 A ( -25 °C ... 70 °C )

Energy storage

Nominal voltage U

N

24 V DC

End-of-charge voltage

25 V DC ... 30 V DC (temperature compensated)

50 V DC ... 60 V DC (temperature compensated)

Nominal capacity range

3 Ah ... 200 Ah

Max. charging current

0.2 A ... 2 A

Signaling

Signaling

LED, active switching outputs, interface/software

LED, active switching output

Interfaces

IFS (Interface system data port) , MINI-USB type B

MINI-USB type B, lockable

General data

Classification according to IEC 62040-3

VFD-SS-311

Weight / Dimensions W x H x D

2.2 kg / 125 x 130 x 125 mm

5 kg / 290 x 130 x 125 mm

Connection method

Screw connection

Connection data input/output solid/stranded/AWG

1.5 - 6 mm² / 1.5 - 4 mm² / 18 - 10

0.2 - 6 mm² / 0.2 - 4 mm² / 30 - 10

Signal connection data (solid/stranded/AWG)

0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 10

0.2 - 1.5 mm² / 0.2 - 1.5 mm² / 24 - 16

Degree of protection / Protection class

IP20 / I

Ambient temperature (operation)

-25 °C ... 70 °C (> 50 °C derating: 2.5%/K)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

Standards/regulations

UL approvals

UL/C-UL Recognized UL 1778

UL/C-UL Recognized UL 1778

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply

, uninterruptible

QUINT-UPS/  1AC/  1AC/500VA

2320270

1

280

PHOENIX CONTACT

QUINT UPS for AC applications

The QUINT UPS delivers a pure sine 

curve at the output for AC applications. The 
sine generated in battery operation is 
synchronous with the mains previously used 
for supply. The QUINT AC-UPS for 
120 V AC/230 V AC with 400 W/500 VA 
power can be combined with all UPS-CAP 
and UPS-BAT energy storage devices.

Optimum use of the buffer time and 

preventive monitoring of the energy 
storage:
– Detects the current state of charge of the 

energy storage and calculates the 
remaining runtime

– Calculates the current life expectancy of 

the energy storage

Worldwide use:

– Input voltages from 96 to 264 V AC
– Storage of the level and frequency of the 

input voltage, in the event of mains failure, 
the output is automatically supplied with 
120 V AC/60 Hz or 230 V AC/50 Hz

– Manual voltage pre-selection possible

Maximum energy efficiency:

– Offline operation: 98% efficiency for 

charged energy storage

– Power factor cos phi 0.8

Extensive signaling and parameterization:

– Switching outputs
– USB  interface
– Data port
– Parameterization with memory module

Simplified startup:

– The UPS can be switched on without a 

power supply network (cold restart)

Power supplies and UPS

Uninterruptible power supplies

H

W

D

Notes:

The buffer time associated with your solution is dependent on the 

load current. Exact details for each uninterruptible power supply 

can be found on page 278

Uninterruptible power supply,

1 AC / 1 AC, 500 VA

phoenixcontact-protection-html.html
background image

C

Input

L

N

O

utput

L

N

Ready

P>Pn

Bat.-Start 230V

SGnd

Alarm

Bat.-Mode

AC 

O

K

Bat.-Start 120V

Remote

C

o

m1

C

o

m

2

=

=

=

=

Parallel

Port

Battery

1

Battery

2

+

-

+

-

For further information and full technical data, visit phoenixcontact.net/products

Technical data

96 V AC ... 264 V AC

45 Hz ... 65 Hz

 ±10 %. Can be configured using UPS-CONF software.

Can be configured using UPS-CONF software

120 V

 

AC

230 V AC

Nominal input voltage

120 V AC

230 V AC

120 V AC

230 V AC

Input voltage range AC

102 V AC ... 138 V AC

196 V AC ... 264 V AC

96 V AC ... 144 V AC

184 V AC ... 264 V AC

Nominal frequency

50 Hz ... 60 Hz

50 Hz ... 60 Hz

60 Hz

50 Hz

)

6.8 A

3.7 A

13 A

7 A

900 W / 1000 VA

> 60 °C (2.5 %/K)

0 ms

> 98 % (Mains operation)

> 92 % (with charged energy storage)

120 V

 

AC

230 V AC

Nominal output voltage

120 V AC

230 V AC

120 V AC

230 V AC

 (continual)

4.3 A ( -25 °C ... 70 °C )

2.2 A ( -25 °C ... 70 °C )

8.3 A ( -25 °C ... 70 °C )

4.4 A ( -25 °C ... 70 °C )

 (continual)

5.2 A ( -25 °C ... 70 °C )

2.7 A ( -25 °C ... 70 °C )

13 A ( -25 °C ... 70 °C )

7 A ( -25 °C ... 70 °C )

120 V

 

AC

230 V AC

Nominal output voltage

120 V AC

230 V AC

120 V AC

230 V AC

 (continual)

4.3 A ( -25 °C ... 50 °C )

2.2 A ( -25 °C ... 50 °C )

8.3 A ( -25 °C ... 70 °C )

4.4 A ( -25 °C ... 70 °C )

 (5 s)

5.2 A ( -25 °C ... 50 °C )

2.7 A ( -25 °C ... 50 °C )

13 A ( -25 °C ... 70 °C )

7 A ( -25 °C ... 70 °C )

2x 24 V DC

End-of-charge voltage

25 V DC ... 30 V DC (temperature compensated)

50 V DC ... 60 V DC (temperature compensated)

7.2 Ah ... 190 Ah

5 A

Signaling

LED, active switching outputs, interface/software

LED, active switching output

Interfaces

IFS (Interface system data port) , MINI-USB type B

MINI-USB type B, lockable

VFI-SS-111

Weight / Dimensions W x H x D

2.2 kg / 125 x 130 x 125 mm

5 kg / 290 x 130 x 125 mm

Screw connection

Connection data input/output solid/stranded/AWG

1.5 - 6 mm² / 1.5 - 4 mm² / 18 - 10

0.2 - 6 mm² / 0.2 - 4 mm² / 30 - 10

Signal connection data (solid/stranded/AWG)

0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 10

0.2 - 1.5 mm² / 0.2 - 1.5 mm² / 24 - 16

IP20 / I

ting: 2.5%/K)

-40 °C ... 70 °C (> 60 °C derating: 2.5%/K)

UL/C-UL Recognized UL 1778

UL/C-UL Recognized UL 1778

Ordering data

Type

Order No.

Pcs./Pkt.

QUINT4-UPS/1AC/1AC/1KVA

2320283

1

281

PHOENIX CONTACT

Power supplies and UPS

Uninterruptible power supplies

H

W

D

new

Uninterruptible power supply,

1 AC / 1 AC, 1 KVA

phoenixcontact-protection-html.html
background image

L

N

P

E

I

nput

L

N

P

E

O

utput

Alarm

B

a

t

.-

Mode

R

e

a

dy

R

e

m

ote

B

a

t

.-S

t

ar

t

SG

nd

C

+

-

3,4 Ah

12 V

3,4 Ah

12 V

Ex

te

r

n

al

ene

r

gy

sto

ra

ge

L

N

P

E

I

nput

L

N

P

E

O

utput

Alarm

B

a

t

.-

Mode

R

e

a

dy

R

e

m

ote

B

a

t

.-S

t

ar

t

SG

nd

C

+

-

3,4 Ah

12 V

3,4 Ah

12 V

Ex

te

r

n

al

ene

r

gy

sto

ra

ge

Technical data

Technical data

Input data

Input voltage range

184 V AC

 

...

 

264 V AC

96 V AC

 

...

 

138 V AC

Frequency range

45 Hz ... 55 Hz

55 Hz ... 65 Hz

Max. current consumption

3 A

6 A

General output data

Input fuse

10 A 400 V gRL

10 A 400 V gRL

General output data

Apparent power / Nominal power

750 VA / 600 W

750 VA / 600 W

Switch-over time

< 10 ms

< 10 ms

Efficiency

> 95 % (with charged energy storage)

> 95 % (with charged energy storage)

Classification according to IEC 62040-3

VFD-SS-311

VFD-SS-311

Output data (mains operation)

Nominal output voltage

230 V AC

120 V AC

Output current

3 A

6 A

Output data (battery operation)

Nominal output voltage

230 V AC

120 V AC

Output current

3 A

6 A

Form of output voltage

Pure sine

Pure sine

Energy storage

Accumulator type

2x Panasonic UP-VW1220P1

2x Panasonic UP-VW1220P1

Buffer period

20 min. (100 W)

 

/

 

4 min. (300 W)

 

/

 

1 min. (600 W)

20 min. (100 W)

 

/

 

4 min. (300 W)

 

/

 

1 min. (600 W)

Signaling

LED signaling

AC OK, Alarm, Battery Mode

AC OK, Alarm, Battery Mode

Transistor switching output

Alarm, Battery Mode, Ready

Alarm, Battery Mode, Ready

Floating signal contact

-

-

General data

Weight / Dimensions W x H x D

5.7 kg / 210 x 170 x 136 mm

5.7 kg / 210 x 170 x 136 mm

Connection method

Push-in connection

Push-in connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

Output connection data (solid/stranded/AWG)

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

4

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

Output connection battery

0.2

 

-

 

10

 

mm² / 0.2

 

-

 

6

 

mm² / 24

 

-

 

8

0.2

 

-

 

10

 

mm² / 0.2

 

-

 

6

 

mm² / 24

 

-

 

8

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

1.5

 

mm² / 0.2

 

-

 

1.5

 

mm² / 24

 

-

 

16

0.2

 

-

 

1.5

 

mm² / 0.2

 

-

 

1.5

 

mm² / 24

 

-

 

16

Degree of protection / Protection class

IP20 / I

IP20 / I

MTBF (IEC 61709, SN 29500)

-

-

Ambient temperature (operation)

0 °C ... 40 °C

0 °C ... 40 °C

Ambient temperature (storage/transport)

-15 °C ... 40 °C (with charged energy storage)

-15 °C ... 40 °C (with charged energy storage)

Standards/regulations

UL approvals

-

UL/C-UL Recognized UL 1778

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply

, uninterruptible

TRIO-UPS-2G/1AC/1AC/230V/750VA

2905909

1

TRIO-UPS-2G/1AC/1AC/120V/750VA

2905908

1

282

PHOENIX CONTACT

The TRIO UPS delivers a pure sine curve 

at the output for AC applications. The sine 
generated in battery operation is 
synchronous with the mains previously used 
for supply. Supply AC loads reliably with the 
new TRIO-UPS-2G uninterruptible power 
supplies for the DIN rail.
– Space-saving: UPS module and energy 

storage are combined in one housing

– Long buffer times with integrated VRLA 

energy storage, can be extended with 
additional energy storage

– USB interface for connection to higher-

level controllers, such as industrial PCs

– Startup from energy storage possible, 

even without mains input

H

W

D

new

H

W

D

new

TRIO UPS for AC applications

Power supplies and UPS

Uninterruptible power supplies

Uninterruptible power supply,

1 AC / 1 AC, 750 VA

Uninterruptible power supply,

1 AC / 1 AC, 750 VA

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Data cable

 for communication between higher-level controllers 

and uninterruptible power supplies

Cable length: 3 m

MINI-SCREW-USB-DATACABLE

2908217

1

283

PHOENIX CONTACT

MINI-SCREW-USB-DATACABLE

– For communication between the 

uninterruptible power supply and the 
UPS CONF configuration software

– Can be locked according to UL 

requirements

USB data cable

Power supplies and UPS

Uninterruptible power supplies

phoenixcontact-protection-html.html
background image

Input

/

O

utput

m

ϑ

C

Input

/

O

utput

m

ϑ

C

 

 

 

 DNV GL

Ex: 

 

 

 

 DNV GL

Ex: 

Technical data

Technical data

Input data

Nominal capacity

0.1 Ah

0.2 Ah

Output data

Nominal output voltage

24 V DC

24 V DC

Output voltage range

22 V DC ... 27 V DC

22 V DC ... 27 V DC

Output current

10 A

20 A

Output fuse

1x 25 A (internal)

2x 25 A (internal)

Can be connected in parallel/series

No / No

No / No

Buffer period

6 min. (1 A) / 33 s (10 A)

12 min. (1 A) / 33 s (20 A)

General data

Storage medium

Double-layer capacitor

Double-layer capacitor

Weight / Dimensions W x H x D

1.7 kg / 126 x 130 x 126 mm

2.9 kg / 150 x 130 x 176 mm

Degree of protection / Protection class

IP20 / III

IP20 / III

Ambient temperature (operation)

-40 °C ... 60 °C

-40 °C ... 60 °C

Ambient temperature (storage/transport)

-40 °C ... 60 °C

-40 °C ... 60 °C

Service life

20 years (20 °C)

20 years (20 °C)

Standards/regulations

UL approvals

UL/C-UL Recognized UL 60950

UL/C-UL Recognized UL 60950

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Energy storage

UPS-CAP/24DC/10A/10KJ

2320377

1

UPS-CAP/24DC/20A/20KJ

2320380

1

284

PHOENIX CONTACT

Maintenance-free CAP UPS

– Double-layer capacitors
– Life expectancy: 

> 20 years (20°C), > 8 years (50°C)

– Communication with QUINT UPS
– Integrated temperature sensor
– Works reliably, even under extreme 

ambient temperatures of -40°C to +60°C

H

W

D

H

W

D

Energy storage for QUINT UPS

Power supplies and UPS

Uninterruptible power supplies

Maintenance-free energy storage,

24 V DC, 10 A, 10 kJ

Maintenance-free energy storage,

24 V DC, 20 A, 20 kJ

phoenixcontact-protection-html.html
background image

Ba

tte

r

y

DC

 24V

m

C

J

12V

12V

DC

 12V

DC

 12V

Ba

tte

r

y

DC

 24V

J

m

C

For further information and full technical data, visit phoenixcontact.net/products

 

 

Ex: 

Technical data

Technical data

Input data/output data

Nominal input voltage

24 V DC

24 V

Nominal capacity

120 Wh

924 Wh

Output current

30 A

45 A

Output fuse

1x 30 A ATOF 32V (breaking capacity 1000 A)

2x 25 A ATOF 32V (breaking capacity 1000 A)

Can be connected in parallel/series

Yes / No

Yes / No

Buffer period

14 min. (20 A)

105 min. (20

 

A (20

 

°C)) / 50 min. (40

 

A (20

 

°C))

General data

Storage medium

LI-ION, 120 Wh

LI-ION, 924 Wh

Weight / Dimensions W x H x D

2.9 kg / 135 x 202 x 110 mm

12.9 kg / 264 x 224 x 197 mm

Degree of protection / Protection class

IP20 / III

IP20 / III

Ambient temperature (operation)

-20 °C ... 60 °C

-25 °C ... 60 °C

Service life

-

15 years (20 °C)

Standards/regulations

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

-

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Energy storage

UPS-BAT/LI-ION/24DC/120WH

2320351

1

UPS-BAT/LI-ION/24DC/924WH

2908232

1

285

PHOENIX CONTACT

UPS-BAT/LI-ION for long service life 
with long buffer times

– Lithium iron phosphate technology
– Works reliably, even under extreme 

ambient temperatures of -20 to +60°C

– Communication with QUINT UPS
– Integrated temperature sensor for 

optimum charging

– Battery can be changed without tools

H

W

D

new

Energy storage for QUINT UPS

Power supplies and UPS

Uninterruptible power supplies

LI-ION energy storage, 

120 Wh

LI-ION energy storage, 

924 Wh

phoenixcontact-protection-html.html
background image

Ba

tte

r

y

DC

 24V

m

C

J

12V

12V

Ba

tte

r

y

DC

 24V

m

C

J

12V

12V

 

 

Ex: 

 

 

 

 DNV GL 

Ex: 

Technical data

Technical data

Input data/output data

Nominal input voltage

24 V DC

24 V DC

Nominal capacity

1.3 Ah

3.4 Ah

Output current

15 A

25 A

Output fuse

1x 15 A

1x 25 A

Can be connected in parallel/series

Yes / No

Yes / No

Buffer period

20 min. (2 A) / 5 min. (5 A)

4.5 min. (20 A) / 3 min. (25 A)

10 min. (20 A) / 3 min. (40 A)

22.5 min. (20 A) / 9 min.

General data

Storage medium

Lead rechargeable battery module

Lead rechargeable battery module

Lead rechargeable battery module

Lead rechargeable

Weight / Dimensions W x H x D

1.7 kg / 54 x 157 x 113 mm

3.3 kg / 85 x 191 x 110 mm

5.9 kg / 135 x 202 x 110 mm

8.9 kg / 202 x 202 

Degree of protection / Protection class

IP20 / III

IP20 / III

Ambient temperature (operation)

0 °C ... 40 °C

0 °C ... 40 °C

Service life

-

6 years ... 9 years (20 °C)

6 years ... 9 years (20 °C)

6 years ... 9 years (20 °C)

-

Standards/regulations

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Energy storage

UPS-BAT/VRLA/24DC/1.3AH

2320296

1

UPS-BAT/VRLA/24DC/3.4AH

2320306

1

Accessories

Accessories

Fuse

FUSE 15A/32V FK1

2908360

2

FUSE 25A/32V ATOF

2908366

2

Mounting set

Mounting set

286

PHOENIX CONTACT

UPS BAT/VRLA for maximum buffer 
times

– Lead AGM (Absorbent Glass Mat) 

technology

– Ambient temperatures from 0 to +40°C
– Long buffer times for high currents
– Communication with QUINT UPS
– Integrated temperature sensor for 

optimum charging

– Battery can be changed without tools

Energy storage for QUINT UPS

Power supplies and UPS

Uninterruptible power supplies

VRLA energy storage, 

1.3 Ah

VRLA energy storage, 

3.4 Ah

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

Ba

tte

r

y

DC

 24V

m

C

J

12V

12V

Ba

tte

r

y

DC

 24V

m

C

J

12V

12V

DC

 12V

DC

 12V

Ba

tte

r

y

DC

 24V

J

m

C

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 DNV GL 

Ex: 

 

 

 

 DNV GL 

Ex: 

 

 

 

 DNV GL

Ex: 

Technical data

Technical data

Technical data

24 V DC

24 V DC

24 V DC

7.2 Ah

12 Ah

38 Ah

50  A

50  A

45  A

2x 25 A

2x 25 A

2x 25 A ATOF 32V

Yes / No

Yes / No

Yes / No

Buffer period

20 min. (2 A) / 5 min. (5 A)

4.5 min. (20 A) / 3 min. (25 A)

10 min. (20 A) / 3 min. (40 A)

22.5 min. (20 A) / 9 min. (40 A)

72 min. (20 A) / 35 min. (40 A)

Storage medium

Lead rechargeable battery module

Lead rechargeable battery module

Lead rechargeable battery module

Lead rechargeable battery module

Lead rechargeable battery module

Weight / Dimensions W x H x D

1.7 kg / 54 x 157 x 113 mm

3.3 kg / 85 x 191 x 110 mm

5.9 kg / 135 x 202 x 110 mm

8.9 kg / 202 x 202 x 110 mm

26 kg / 330 x 221 x 197 mm

IP20 / III

IP20 / III

IP20 / III

0 °C ... 40 °C

0 °C ... 40 °C

0 °C ... 40 °C

Service life

-

6 years ... 9 years (20 °C)

6 years ... 9 years (20 °C)

6 years ... 9 years (20 °C)

-

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

UPS-BAT/VRLA/24DC/7.2AH

2320319

1

UPS-BAT/VRLA/24DC/12AH

2320322

1

UPS-BAT/VRLA/24DC/38AH

2320335

1

Accessories

Accessories

Accessories

FUSE 25A/32V ATOF

2908366

2

FUSE 25A/32V ATOF

2908366

2

FUSE 25A/32V ATOF

2908366

2

BATTERY MOUNTING KIT

2320788

1

BATTERY MOUNTING CASE

2320458

1

287

PHOENIX CONTACT

Power supplies and UPS

Uninterruptible power supplies

VRLA energy storage, 

7.2 Ah

VRLA energy storage, 

12 Ah

VRLA energy storage, 

38 Ah

H

W

D

H

W

D

phoenixcontact-protection-html.html
background image

DC

 12V

DC

 12V

Ba

tte

r

y

DC

 24V

J

m

C

DC

 12V

DC

 12V

Ba

tte

r

y

DC

 24V

J

m

C

 

 

 

 DNV GL 

 

Ex: 

 

 

 

 DNV GL 

 

Ex: 

Technical data

Technical data

Input data/output data

Nominal input voltage

24 V DC

24 V DC

Nominal capacity

13 Ah

26 Ah

Output current

45 A

45 A

Output fuse

2x 25 A ATOF 32V

2x 25 A ATOF 32V

Can be connected in parallel/series

Yes / No

Yes / No

Buffer period

50 min. (10 A) / 10 min. (40 A)

120 min. (10 A) / 30 min. (40 A)

General data

Storage medium

Pure lead AGM

Pure lead AGM

Weight / Dimensions W x H x D

10.8 kg / 172 x 177 x 178 mm

21.6 kg / 358 x 174 x 169 mm

Degree of protection / Protection class

IP20 / III

IP20 / III

Ambient temperature (operation)

-25 °C ... 60 °C

-25 °C ... 60 °C

Ambient temperature (storage/transport)

-40 °C ... 60 °C

-40 °C ... 60 °C

Service life

-

-

Standards/regulations

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

GL approvals

Germanischer Lloyd (EMC 2), ABS, DNV

Germanischer Lloyd (EMC 2), ABS, DNV

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Energy storage

UPS-BAT/VRLA-WTR/24DC/13AH

2320416

1

UPS-BAT/VRLA-WTR/24DC/26AH

2320429

1

Accessories

Accessories

Fuse

FUSE 25A/32V ATOF

2908366

2

FUSE 25A/32V ATOF

2908366

2

Mounting set

BATTERY MOUNTING KIT

2320788

1

BATTERY MOUNTING KIT

2320788

1

Mounting set

BATTERY MOUNTING CASE

2320458

1

BATTERY MOUNTING CASE

2320458

1

288

PHOENIX CONTACT

UPS BAT/VRLA-WTR for 
temperatures from -25 to +60°C

– Pure  lead  AGM  technology
– Communication with QUINT UPS
– Integrated temperature sensor for 

optimum charging

Energy storage for QUINT UPS

Power supplies and UPS

Uninterruptible power supplies

Energy storage with 

wide temperature range

24 V DC, 13 Ah

Energy storage with 

wide temperature range

24 V DC, 26 Ah

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

 DNV GL

 DNV GL

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Mounting set

BATTERY MOUNTING KIT

2320788

1

BATTERY MOUNTING CASE

2320458

1

289

PHOENIX CONTACT

Power supplies and UPS

Uninterruptible power supplies

Battery mounting kit

– For attaching individual battery blocks to 

a mounting plate

– Consists of four powder-coated metal 

brackets and a fabric lashing strap

Battery mounting case

– Battery frame for universal wall or surface 

mounting of battery blocks and 
electronics

Mounting accessories

phoenixcontact-protection-html.html
background image

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Configuration software

 for QUINT UPS

UPS-CONF

2320403

1

The UPS CONF configuration software 

can be downloaded free of charge from our 
homepage. Remember to order the IFS-
USB-DATACABLE as well in order to use 
the software.

Supported operating systems:

– Windows 8.1 (32 and 64-bit)
– Windows 8.0 (32 and 64-bit)
– Windows 7 (32 and 64-bit)
– Windows 10 (32 and 64-bit)

Minimum requirements:

– Display: 800 x 600, 256 colors
– Processor: 400 MHz, Pentium processor 

or similar

– RAM:  96  MB

Configuration software for 
QUINT UPS

Power supplies and UPS

Uninterruptible power supplies

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Programming adapter

 for configuring modules with S-PORT 

interface

Cable length: 3 m

IFS-USB-DATACABLE

2320500

1

Multi-functional memory module

 for the Interface system

- Flat design

IFS-CONFSTICK

2986122

1

- Tall design

IFS-CONFSTICK-L

2901103

1

290

PHOENIX CONTACT

IFS-USB-DATACABLE

– For communication between the 

uninterruptible power supply and the UPS 
CONF configuration software

IFS-CONFSTICK

– For storing the values you have configured 

and quickly transferring them to other 
uninterruptible power supplies

Accessories for QUINT UPS and 
TRIO DC-UPS

Memory module

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Data cable

 for communication between higher-level controllers 

and QUINT UPS uninterruptible power supplies, cable length: 2 m

Modbus communication

IFS-RS232-DATACABLE

2320490

1

Direct communication

IFS-MINI-DIN-DATACABLE

2320487

1

Flexible communication

IFS-OPEN-END-DATACABLE

2320450

1

IFS-RS232-DATACABLE

– For Modbus communication with the 

RS-232 interface

– Connection to the Phoenix Contact 

COM server for Ethernet communication

– Communicate directly with higher-level 

controllers, such as Phoenix Contact ILC 
or RFC, or use as a gateway

IFS-MINI-DIN-DATACABLE

– For direct communication with the ILC 

from the Phoenix Contact Inline system

IFS-OPEN-END-DATACABLE

– Open cable for flexible communication

QUINT UPS function blocks

– For further processing of information 

communicated via data cables

– For PC Worx software
– Free download at 

phoenixcontact.net/products

Accessories for QUINT UPS and 
TRIO DC-UPS

Power supplies and UPS

Uninterruptible power supplies

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Bluetooth programming adapter, 

with USB and S-PORT 

interface

IFS-BT-PROG-ADAPTER

2905872

1

291

PHOENIX CONTACT

IFS-BT-PROG-ADAPTER

– For wireless communication between the 

uninterruptible power supply and the 
UPS CONF configuration software

Accessories for QUINT UPS and 
TRIO DC-UPS

Bluetooth adapter

phoenixcontact-protection-html.html
background image

292

PHOENIX CONTACT

Selection of UPS modules with integrated energy storage 
or integrated power supply

To save space in the control cabinet or to 

retrofit existing systems easily, UPS versions 
with integrated energy storage (QUINT, 
UNO, and STEP) or integrated power 
supply (MINI and TRIO) are recommended.

Buffer times for QUINT CAP 

Buffer times for UNO UPS and 
STEP UPS

Select your UPS solution here.

Example: 2.5 A needs to be buffered for 

10 minutes:

Solution:
STEP-UPS/24DC/24DC/3

Buffer time

Seconds

Minutes

Hours

0.2

0.4

1

2

8

16

30

1

2

3

5

6

7

8

9

10

15

20

25

30

40

45

50

1

2

3

Lo

a

d

 c

u

r

r

e

n

t

0.5 A

1 A

1.5 A

2 A

2.5 A

3 A

4 A

UPS modules with integrated energy storage

UNO-UPS/24DC/24DC/60W

STEP-UPS/24DC/24DC/3

STEP-UPS/12DC/12DC/4

The data is based on an ambient temperature of +20°C.

The data is based on an ambient temperature of +25°C.

Buffer time

Seconds

Minutes

15

20

30

40

50

1

2

3

5

Loa

d

 c

u

r

ren

t

1 A

2.5 A

5 A

6.25 A

7.5 A

10 A

12.5 A

UPS modules with integrated energy storage

QUINT4-CAP/24DC/5/4KJ

QUINT4-CAP/24DC/10/8KJ

Select your UPS solution here.

Example: 5 A needs to be buffered for 

40 seconds:

Solution:
QUINT4-CAP/24DC/10/8KJ

Power supplies and UPS

Uninterruptible power supplies

phoenixcontact-protection-html.html
background image

2x

2x

For further information and full technical data, visit phoenixcontact.net/products

293

PHOENIX CONTACT

Buffer times for QUINT UPS and 
QUINT BUFFER

Particularly space-saving: UPS module and 

energy storage combined in one housing. 
You simply need to connect a power supply 
upstream.

Buffer times for MINI UPS and 
TRIO UPS     

Particularly space-saving: UPS module and 

power supply combined in one housing. You 
simply need to connect an energy storage 
device upstream.

MINI UPS

Energy storage with lead AGM 

technology for output voltages of 24 or 
12 V DC. Buffer times of up to 50 minutes 
with 1 A load current.

Note: With the MINI-DC-UPS/12DC/4, 

buffer times are double those of the 
MINI-DC-UPS/24DC/2.

TRIO UPS

Energy storage with lead AGM 

technology buffer failures lasting up to 
2 hours with 5 A load current.

Select the energy storage for your 

MINI UPS and TRIO UPS here.

Example: 2 A needs to be buffered for 

20 minutes.

Solution: 
MINI-DC-UPS/24DC/2 and 
MINI-BAT/24DC/1.3AH

Buffer time

Seconds

Minutes

Hours

0.2 0.4 0.5

1

1.5

2

4

6

8

16

30

1

2

3

5

6

7

8

9

10

15

20

25

30

40

45

50

1

2

3

Lo

a

d

 c

u

r

r

e

n

t

0.5 A

1 A

2 A

3 A

5 A

7 A

10 A

20 A

30 A

40 A

Energy storage

QUINT4-BUFFER/24DC/20

QUINT-UPS/24DC/24DC/5/1.3AH

QUINT4-BUFFER/24DC/40

QUINT-UPS/24DC/24DC/10/3.4AH

Buffer time

Minutes

Hours

2

3

5

6

7

8

9

10

20

30

40

45

50

1

2

3

Lo

a

d

 cu

r

r

e

n

t

0.5 A

1 A

1.5 A

2 A

3 A

4 A

5 A

Energy storage for:

MINI UPS

Energy storage for:

TRIO UPS

MINI-BAT/24DC/0.8AH

MINI-BAT/24DC/1.3AH

MINI-BAT/24DC/1.3AH

QUINT-BAT/24DC/3.4AH

MINI-BAT/12DC/1.6AH

QUINT-BAT/24DC/7.2AH

MINI-BAT/12DC/2.6AH

QUINT-BAT/24DC/12AH

Select your QUINT UPS or QUINT 

BUFFER here.

Example: 5 A needs to be buffered for 

20 minutes.

Solution: 
QUINT-UPS/24DC/24DC/10/3.4AH

The data is based on an ambient temperature of +20°C.

The data is based on an ambient temperature of +20°C.

Power supplies and UPS

Uninterruptible power supplies

phoenixcontact-protection-html.html
background image

13

23

33

14

24

34

R

1

R

2

A

larm

Ba

t.-

Mode

Ba

t.-

C

h

ar

ge

R

e

m

ote

C

onfi

rm

Da

t

a

-Po

r

t

Input

DC

 24V

O

utput

DC

 24V

24V 

0

.2A

I  < I

N

m

C

J

t

[

m

in]

max

Ba

tte

r

y

24V

DC

J

13

23

33

14

24

34

R

1

R

2

A

larm

Ba

t.-

Mode

Ba

t.-

C

h

ar

ge

R

e

m

ote

C

onfi

rm

Da

t

a

-Po

r

t

Input

DC

 24V

O

utput

DC

 24V

24V 

0

.2A

I  < I

N

m

C

J

t

[

m

in]

max

Ba

tte

r

y

24V

DC

J

 

 

Ex: 

 

 

Ex: 

Technical data

Technical data

Input data

Input voltage range

18 V DC

 

...

 

30 V DC

18 V DC

 

...

 

30 V DC

Max. current consumption

9.3 A (24 V DC)

18.6 A (24 V DC)

Output data

Nominal output voltage

24 V DC

24 V DC

Output voltage range

19.2 V DC ... 27.6 V DC (U

OUT

 = U

BAT

 - 0.5 V DC)

19.2 V DC ... 27.6 V DC (U

OUT

 = U

BAT

 - 0.5 V DC)

Output current

5 A

10 A

Can be connected in parallel/series

Yes / No

Yes / No

Buffer period

50 min. (1 A) / 5 min. (5 A)

180 min. (1 A) / 10 min. (10 A)

Max. power dissipation (normal mode / buffer mode)

2.5 W / 3.3 W

3.1 W / 6.3 W

Efficiency

> 97.1 % (Mains operation, with charged energy storage)

> 97.6 % (Mains operation, with charged energy storage)

Signaling

Signaling

LED, relay contact, interface/software

LED, relay contact, interface/software

Interfaces

IFS (Interface system data port)

IFS (Interface system data port)

General data

Storage medium

Lead rechargeable battery module 1.3 Ah

Lead rechargeable battery module, 3.4 Ah

Weight / Dimensions W x H x D

2.2 kg / 88 x 138 x 125 mm

3.8 kg / 120 x 169 x 125 mm

Mounting position

horizontal DIN rail NS 35, EN 60715

horizontal DIN rail NS 35, EN 60715

Assembly instructions

Can be aligned: horizontal 5 mm, vertical 50 mm

Can be aligned: horizontal 5 mm, vertical 50 mm

Connection method

Plug-in screw connection

Plug-in screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 20

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 20

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 16

 

-

 

12

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

Degree of protection / Protection class

IP20 / III

IP20 / III

MTBF (IEC 61709, SN 29500)

> 806000 h (40°C)

> 806000 h (40°C)

Ambient temperature (operation)

0 °C ... 40 °C

0 °C ... 40 °C

Ambient temperature (storage/transport)

-15 °C ... 40 °C

-15 °C ... 40 °C

Service life

6 years ... 9 years (20 °C)

6 years ... 9 years (20 °C)

Latest startup

3 months (0 °C ... 20 °C)

1 month (30 °C ... 40 °C)

6 months (0 °C ... 20 °C)

Standards/regulations

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety, safety transformer

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

UL approvals

UL/C-UL Recognized UL 60950 , UL Listed UL 508

UL/C-UL Recognized UL 60950 , UL Listed UL 508

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply

, uninterruptible

QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH

2320254

1

QUINT-UPS/ 24DC/ 24DC/10/3.4AH

2320267

1

Accessories

Accessories

Fuse

FUSE 15A/32V FKS ATO

2908361

2

FUSE 15A/32V FKS ATO

2908361

2

294

PHOENIX CONTACT

QUINT-UPS is very easy to install in 

existing systems. You simply need to 
connect a 24 V DC power supply unit 
upstream and the reliable UPS solution is 
complete.
– Advantages of using IQ technology
– Minimal  wiring  effort
– Maintenance-free energy storage with 

lead AGM technology

Notes:

The buffer time associated with your solution is dependent on the 

load current. Exact details for each uninterruptible power supply 

can be found on page 293.

H

W

D

H

W

D

UPS module with integrated energy 
storage

Power supplies and UPS

Uninterruptible power supplies

Uninterruptible power supply

with integrated energy storage,

24 V DC / 24 V DC, 5 A, 1.3 Ah

Uninterruptible power supply

with integrated energy storage,

24 V DC / 24 V DC, 10 A, 3.4 Ah

phoenixcontact-protection-html.html
background image

=

=

=

=

Inrush

Charge

Discharge

U

O

K

In

Ready

SGnd

13

14

+

+

-

-

C

=

=

=

=

Inrush

Charge

Discharge

U

O

K

In

Ready

SGnd

13

14

+

+

-

-

C

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Input data

Input voltage range

22.5 V DC

 

...

 

30 V DC

22.5 V DC

 

...

 

30 V DC

Current consumption (idling/charging process/max.)

0.2 A / 0.6 A / 26 A

0.2 A / 0.8 A / 46 A

Connect threshold (fixed, variable)

< 22 V DC , (U

IN

 - 1 V)/0.1 s

< 22 V DC , (U

IN

 - 1 V)/0.1 s

Output data

Nominal output voltage

24 V DC

24 V DC

Output current I

N

 / I

Stat. Boost 

/ I

Dyn. Boost 

/ I

SFB

20 A / 25 A / 30 A (5 s) / 120 A (15 ms)

40 A / 45 A / 60 A (5 s) / 215 A (15 ms)

Can be connected in parallel/series

No / No

No / No

Buffer period

200 ms (20 A)

200 ms (40 A)

Maximum power dissipation for nominal condition

< 6 W

< 9 W

Signaling

LED signaling

U

IN

 OK, Ready

U

IN

 OK, Ready

Transistor switching output

Ready

Ready

Floating signal contact

U

IN

OK

U

IN

OK

General data

Storage medium

Electrolytic capacitor

Electrolytic capacitor

Weight / Dimensions W x H x D

1 kg / 57 x 130 x 125 mm

1.2 kg / 73 x 130 x 125 mm

Mounting position

horizontal DIN rail NS 35, EN 60715

horizontal DIN rail NS 35, EN 60715

Assembly instructions

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Connection method

Screw connection

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 30

 

-

 

10

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 10

 

-

 

6

Output connection data (solid/stranded/AWG)

0.2

 

-

 

6

 

mm² / 0.2

 

-

 

4

 

mm² / 30

 

-

 

10

0.5

 

-

 

16

 

mm² / 0.5

 

-

 

16

 

mm² / 10

 

-

 

6

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

1.5

 

mm² / 0.2

 

-

 

1.5

 

mm² / 24

 

-

 

16

0.2

 

-

 

1.5

 

mm² / 0.2

 

-

 

1.5

 

mm² / 24

 

-

 

16

Degree of protection / Protection class

IP20 / II

IP20 / II

MTBF (IEC 61709, SN 29500)

> 

2497000

 h (40°C)

2814000

 h (40°C)

Ambient temperature (operation)

-40 °C ... 70 °C

-40 °C ... 70 °C

Standards/regulations

Insulation voltage: input, output/housing

500 V

500 V

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

-

-

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950

UL Listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Buffer module,

 maintenance-free

QUINT4-BUFFER/24DC/20

2907913

1

QUINT4-BUFFER/24DC/40

2908283

1

295

PHOENIX CONTACT

The QUINT BUFFER is ideal for failures 

lasting just seconds.

It combines an electronic switch-over 

unit and a capacitor-based energy storage in 
the same housing.
– Fast tripping of standard miniature circuit 

breakers with SFB (Selective Fuse 
Breaking) Technology dynamic power 
reserve with up to 6 times the nominal 
current for 12 ms

– Space savings thanks to compact design

Notes:

The buffer time associated with your solution is dependent on the 

load current. Exact details for each uninterruptible power supply 

can be found on page 293.

H

W

D

new

H

W

D

new

Maintenance-free buffer module

Power supplies and UPS

Uninterruptible power supplies

Maintenance-free capacity module

24 V DC / 20 A

Maintenance-free capacity module

24 V DC / 40 A

phoenixcontact-protection-html.html
background image

=

=

C

=

=

=

=

Inrush

EMI Filter

Charge

Discharge

Soft Start

Input

+

-

O

utput

+

-

U

O

K

In

Alarm

Ready

Remote

SGnd

13

14

Technical data

Input data

Input voltage range

22.5 V DC

 

...

 

30 V DC

Current consumption (idling/charging process/max.)

0.1 A / 0.8 A / 7 A

Connect threshold (fixed, variable)

< 22 V DC , -

Output data

Nominal output voltage

24 V DC

Output current I

N

 / I

Stat. Boost 

/ I

Dyn. Boost 

/ I

SFB

5 A / 6.25 A / 10 A (5 s) / 30 A (15 ms)

10 A / 12.5 A / 20 A (5 s) / 60 A (15 ms)

Can be connected in parallel/series

Yes / No

Buffer period

3 min. (1 A) / 1 min. (2.5 A) / 30 s (5 A)

5 min. (1 A) / 1 min. (5 A) / 30 s (10 A)

Maximum power dissipation for nominal condition

< 3 W

Signaling

LED signaling

U

IN

 OK, Alarm, Ready

Transistor switching output

Alarm, Ready

Floating signal contact

U

IN

OK

General data

Storage medium

Double-layer capacitor

Double-layer capacitor

Weight / Dimensions W x H x D

1.3 kg / 94 x 130 x 125 mm

1.6 kg / 118 x 130 x 125 mm

Mounting position

horizontal DIN rail NS 35, EN 60715

horizontal DIN rail NS 35, EN 60715

Assembly instructions

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Connection method

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 30

 

-

 

12

0.2

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 30

 

-

 

12

0.2

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

1.5

 

mm² / 0.2

 

-

 

1.5

 

mm² / 24

 

-

 

16

0.2

Degree of protection / Protection class

IP20 / II

MTBF (IEC 61709, SN 29500)

1302000

 h (40°C)

Ambient temperature (operation)

-40 °C ... 60 °C

Standards/regulations

Insulation voltage: input, output/housing

500 V

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

-

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950

UL Listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Buffer module,

 maintenance-free

QUINT4-CAP/24DC/5/4KJ

2320539

1

296

PHOENIX CONTACT

Maintenance-free buffer module

QUINT CAP is ideal for cyclical failures 

lasting up to 30 seconds. It combines an 
electronic switch-over unit and a capacitor-
based energy storage device in the same 
housing.
– Convenient PC shutdown
– Maintenance-free with a long service life
– Space savings thanks to compact design
– Long buffer time thanks to high memory 

capacity

Power supplies and UPS

Uninterruptible power supplies

H

W

D

new

Notes:

The buffer time associated with your solution is dependent on the 

load current. Exact details for each uninterruptible power supply 

can be found on page 292.

Maintenance-free Ultra-CAP

Capacity module

24 V DC, 5 A

phoenixcontact-protection-html.html
background image

=

=

C

=

=

=

=

Inrush

EMI Filter

Charge

Discharge

Soft Start

Input

+

-

O

utput

+

-

U

O

K

In

Alarm

Ready

Remote

SGnd

13

14

For further information and full technical data, visit phoenixcontact.net/products

Technical data

22.5 V DC

 

...

 

30 V DC

0.1 A / 1 A / 13.5 A

< 22 V DC , -

24 V DC

5 A / 6.25 A / 10 A (5 s) / 30 A (15 ms)

10 A / 12.5 A / 20 A (5 s) / 60 A (15 ms)

Yes / No

Buffer period

3 min. (1 A) / 1 min. (2.5 A) / 30 s (5 A)

5 min. (1 A) / 1 min. (5 A) / 30 s (10 A)

< 6 W

U

IN

 OK, Alarm, Ready

Alarm, Ready

U

IN

OK

Storage medium

Double-layer capacitor

Double-layer capacitor

Weight / Dimensions W x H x D

1.3 kg / 94 x 130 x 125 mm

1.6 kg / 118 x 130 x 125 mm

Mounting position

horizontal DIN rail NS 35, EN 60715

horizontal DIN rail NS 35, EN 60715

Assembly instructions

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Screw connection

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 30

 

-

 

12

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 30

 

-

 

12

16

0.2

 

-

 

1.5

 

mm² / 0.2

 

-

 

1.5

 

mm² / 24

 

-

 

16

IP20 / II

1387000

 h (40°C)

-40 °C ... 60 °C

500 V

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety

IEC 60950-1/VDE 0805 (SELV)

IEC 60950-1/VDE 0805 (SELV)

-

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950

UL Listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data

Type

Order No.

Pcs./Pkt.

QUINT4-CAP/24DC/10/8KJ

2320571

1

297

PHOENIX CONTACT

Power supplies and UPS

Uninterruptible power supplies

H

W

D

new

Maintenance-free Ultra-CAP

Capacity module

24 V DC, 10 A

phoenixcontact-protection-html.html
background image

A

larm

Ba

t.- Mode

Ba

t.- 

C

h

ar

ge

G

N

D

R

1

R

2

R

e

m

ote

Ba

tte

r

y

Input

DC

 24V

O

utput

DC

 24V

m

C

t
[

m

in]

max

J

A

larm

Ba

t.- Mode

Ba

t.- 

C

h

ar

ge

G

N

D

R

1

R

2

R

e

m

ote

Ba

tte

r

y

Input

DC

 12V

O

utput

DC

 12V

m

C

t
[

m

in]

max

J

 

 

 

 

 

 

Technical data

Technical data

Input data

Nominal input voltage range

24 V DC

12 V DC

Input voltage range

22.5 V DC

 

...

 

29.5 V DC

10 V DC

 

...

 

16.5 V DC

Max. current consumption

4.7 A

6 A

Current consumption charging process

0.5 A

0.8 A

Input fuse

7 A (slow-blow, internal)

7 A (slow-blow, internal)

Output data

Nominal output voltage

24 V DC

12 V DC

Output current standard operation

3 A

4 A

Output current Power

 

Boost

4 A (0 °C ... 35 °C)

5 A (0 °C ... 35 °C)

Can be connected in parallel/series

No / No

No / No

Buffer period

50 min. (1 A) / 25 min. (2 A) / 17 min. (3 A)

100 min. (1 A) / 50 min. (2 A) / 30 min. (3 A)

Max. power dissipation (normal mode / buffer mode)

2 W / 3.8 W

1.2 W / 4.4 W

Efficiency

> 98 % (Mains operation, with charged energy storage)

 

/

 

> 95 % (Battery operation)

> 97.4 % (Mains operation, with charged energy storage)

 

/

 

> 92 % (Battery operation)

Signaling

Signaling Power OK

LED

LED

Signaling alarm

LED, active transistor switching output

LED, active transistor switching output

Signaling battery charge

LED, active transistor switching output

LED, active transistor switching output

Signaling battery mode

LED, active transistor switching output

LED, active transistor switching output

General data

Storage medium

Lithium polymer

Lithium polymer

Weight / Dimensions W x H x D

0.45 kg / 108 x 90 x 61 mm

0.46 kg / 108 x 90 x 61 mm

Mounting position

horizontal DIN rail NS 35, EN 60715

horizontal DIN rail NS 35, EN 60715

Assembly instructions

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Connection method

Screw connection

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

Degree of protection / Protection class

IP20 / III

IP20 / III

MTBF (IEC 61709, SN 29500)

1401000

 h (40°C)

1997000

 h (40°C)

Ambient temperature (operation)

0 °C ... 40 °C

0 °C ... 40 °C

Standards/regulations

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety, safety transformer

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950

UL Listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply

, uninterruptible

STEP-UPS/24DC/24DC/3

2868703

1

STEP-UPS/12DC/12DC/4

2868693

1

Accessories

Accessories

Energy storage

STEP-BAT/LIPO/18.5DC/1.4AH

2320364

1

STEP-BAT/LIPO/18.5DC/1.4AH

2320364

1

298

PHOENIX CONTACT

STEP UPS

The STEP BAT energy storage is included 

when ordering the STEP UPS. The 
STEP BAT can be reordered separately. (See 
accessories on this page)

Notes:

With the STEP-UPS/12DC/12DC/4, buffer times are double those 

of the STEP-UPS/24DC/24 DC/3. See page 292.

The buffer time associated with your solution is dependent on the 

load current. Exact details for each uninterruptible power supply 

can be found on page 292.

H

W

D

H

W

D

UPS module with integrated energy 
storage

Power supplies and UPS

Uninterruptible power supplies

Uninterruptible power supply

with integrated rechargeable battery,

24 V DC / 24 V DC, 3 A

Uninterruptible power supply

with integrated battery module,

12 V DC/12 V DC, 4 A

phoenixcontact-protection-html.html
background image

+

O

utput

R1

R

2

Alarm

B

a

t

.-

Mode

+

I

nput

R

e

m

ote

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

Technical data

Input data

Nominal input voltage range

24 V DC

Input voltage range

22.5 V DC

 

...

 

29.5 V DC

Max. current consumption

2.8 A

Current consumption charging process

-

Input fuse

5 A (electronic)

Output data

Nominal output voltage

24 V DC (SELV)

Output current standard operation

2.5 A

Output current Power

 

Boost

-

Can be connected in parallel/series

yes, with redundancy module / No

Buffer period

45 min. (0.5 A) / 20 min. (1 A) / 8 min. (2 A)

Max. power dissipation (normal mode / buffer mode)

3 W / -

Efficiency

> 95 % (Mains operation, with charged energy storage)

 

/

 

> 92 % (Battery operation)

Signaling

Signaling Power OK

LED

Signaling alarm

LED, active transistor switching output

Signaling battery charge

-

Signaling battery mode

LED, active transistor switching output

General data

Storage medium

Lead rechargeable battery module

Weight / Dimensions W x H x D

1 kg / 110 x 90 x 84 mm

Mounting position

horizontal DIN rail NS 35, EN 60715

Assembly instructions

Alignable: 0 mm horizontally, 30 mm vertically

Connection method

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

14

Degree of protection / Protection class

IP20 / III

MTBF (IEC 61709, SN 29500)

> 

1900000

 h (40°C)

Ambient temperature (operation)

-15 °C ... 50 °C

Standards/regulations

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Electrical safety, safety transformer

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply

, uninterruptible

UNO-UPS/24DC/24DC/60W

2905907

1

Accessories

Fuse

FUSE  5A/32V FK-1

2908367

2

299

PHOENIX CONTACT

UNO UPS

The energy storage is included when 

ordering the UNO UPS.

Notes:

The buffer time associated with your solution is dependent on the 

load current. Exact details for each uninterruptible power supply 

can be found on page 292.

H

W

D

UPS module with integrated energy 
storage

Power supplies and UPS

Uninterruptible power supplies

Uninterruptible power supply

with integrated rechargeable battery,

24 V DC/24 V DC, 60 W

phoenixcontact-protection-html.html
background image

t...[min]

J

J

Output DC

24 V 5 A

Remote
On/Off

2x 12V

Battery

PS

Alarm

Bat.-Charge

Bat.-Mode

IFS

Config.-Port

Confirm

L (+)

N (-)

R1

R2

 

 

 DNV GL 

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

Input voltage range

85 V AC

 

...

 

264 V AC

 

/

 

100 V DC

 

...

 

350 V DC

Max. current consumption in normal mode

0.95 A (230 V AC) / 1.1 A (230

 

V

 

AC, maximum) , 

1.7 A (120 V AC) / 1.8 A (120

 

V

 

AC, maximum)

Input fuse

6.3 A (slow-blow, internal)

Reliable backup fuse, circuit breaker

B6 , B10 , B16

Output data

Nominal output voltage

24 V DC

Output current

5 A

Can be connected in parallel/series

No / No

Buffer period

20 min. (5 A)

Max. power dissipation (normal mode / buffer mode)

16 W / 4 W

Efficiency

> 88 % (230 V AC, mains operation)

 

/

 

> 86 % (120 V AC, mains 

operation)

 

/

 

> 86 % (Battery operation)

Signaling

Interfaces

IFS (Interface system data port)

Signaling Power OK

LED

Signaling alarm

LED, active switching output

Signaling battery charge

LED, active switching output

Signaling battery mode

LED, active switching output

General data

Storage medium

External, battery 1.3 Ah / 3.4 Ah / 7.2 Ah / 12 Ah

Weight / Dimensions W x H x D

1.1 kg / 60 x 130 x 118 mm

Mounting position

horizontal DIN rail NS 35, EN 60715

Assembly instructions

Can be aligned: Horizontally 0 mm, vertically 50 mm

Connection method

Screw connection

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

Degree of protection / Protection class

IP20 / I

MTBF (IEC 61709, SN 29500)

> 596000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating: 2.5%/K)

Standards/regulations

Insulation voltage input/output

2 kV (routine test) / 4 kV (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Electrical safety, safety transformer

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

UL approvals

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Power supply

, uninterruptible

TRIO-UPS/1AC/24DC/ 5

2866611

1

300

PHOENIX CONTACT

TRIO UPS

Developed specifically for supplying 

industrial PCs. Configuration port: freely 
parameterizable with the UPS CONF 
configuration software. Configuration stick: 
parameterize stick once and transfer to any 
number of TRIO UPS units.

The UPS-CONF (Order No

2320403

configuration software can be downloaded 
free of charge from our homepage.

Notes:

The buffer time associated with your solution is dependent on the 

load current. Exact details for each uninterruptible power supply 

can be found on page 293.

H

W

D

UPS module with integrated power 
supply

Power supplies and UPS

Uninterruptible power supplies

UPS with integrated power supply,

100 - 240 V AC / 24 V DC, 5 A

phoenixcontact-protection-html.html
background image

-

+

-

+

L(+)

N(-)

+24 V/2A

Alarm

Remote

On/Off

B

at. Mode

B

attery

Charge

t...[min]

R1

R2

PS

-

+

-

+

L(+)

N(-)

+12 V/4A

Alarm

Remote

On/Off

B

at. Mode

B

attery

Charge

t...[min]

R1

R2

PS

For further information and full technical data, visit phoenixcontact.net/products

 

 

Ex: 

 

 

Ex: 

Technical data

Technical data

Input data

Nominal input voltage range

100 V AC ... 240 V AC

100 V AC ... 240 V AC

Input voltage range

85 V AC

 

...

 

264 V AC

 

/

 

100 V DC

 

...

 

350 V DC

85 V AC

 

...

 

264 V AC

 

/

 

100 V DC

 

...

 

350 V DC

Max. current consumption in normal mode

0.6 A / 0.85 A (230 V AC) , 

1.1 A / 1.5 A (120 V AC)

0.5 A / 0.65 A (230 V AC) , 

1.15 A / 1.35 A (120 V AC)

Input fuse

3.15 A (slow-blow, internal)

3.15 A (slow-blow, internal)

Reliable backup fuse, circuit breaker

B6 , B10 , B16

B6 , B10 , B16

Output data

Nominal output voltage

24 V DC (AC input voltage available: 22.5 to 29.5 V DC, AC input 

voltage not available: 27.9 to 19.2 V DC)

12 V DC (AC input voltage available: 10 to 16 V DC, AC input voltage 

not available: 13.6 to 9.6 V DC)

Output current

2 A

4 A

Can be connected in parallel/series

No / yes

No / yes

Buffer period

20 min. (2 A)

20 min. (4 A)

Max. power dissipation (idling / normal mode / buffer mode)

3.8 W / 10.1 W / 2.1 W

1.6 W / 10.5 W / 2.6 W

Efficiency

> 83 %

> 82 %

Signaling

Signaling Power OK

LED

LED

Signaling alarm

LED, active switching output

LED, active switching output

Signaling battery charge

LED, active switching output

LED, active switching output

Signaling battery mode

LED, active switching output

LED, active switching output

General data

Storage medium

External, battery 0.8 Ah / 1.3 Ah

External, rechargeable battery 1.6 Ah / 2.6 Ah

Weight / Dimensions W x H x D

0.45 kg / 67.5 x 99 x 107 mm

0.45 kg / 67.5 x 99 x 107 mm

Mounting position

horizontal DIN rail NS 35, EN 60715

horizontal DIN rail NS 35, EN 60715

Assembly instructions

Can be aligned: Horizontally 0 mm, vertically 50 mm

Can be aligned: Horizontally 0 mm, vertically 50 mm

Connection method

COMBICON plug-in screw connections

COMBICON plug-in screw connections

Input connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

Output connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

Signal connection data (solid/stranded/AWG)

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

0.2

 

-

 

2.5

 

mm² / 0.2

 

-

 

2.5

 

mm² / 24

 

-

 

12

Degree of protection / Protection class

IP20 / II

IP20 / II

MTBF (IEC 61709, SN 29500)

> 753000 h (40°C)

> 728000 h (40°C)

Ambient temperature (operation)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

-25 °C ... 70 °C (> 60 °C derating: 2.5%/K)

Standards/regulations

Insulation voltage input/output

2 kV (routine test) / 4 kV (type test)

2 kV (routine test) / 4 kV (type test)

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Conformance with EMC Directive 2014/30/EU

Electrical safety, safety transformer

EN 60950-1/VDE 0805 (SELV)

EN 60950-1/VDE 0805 (SELV)

Electronic equipm. for electrical power installations

EN 50178/VDE 0160 (PELV)

EN 50178/VDE 0160 (PELV)

UL approvals

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

UL Listed UL 508 , UL/C-UL Recognized UL 60950 , 

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D 

(Hazardous Location)

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Power supply

, uninterruptible

MINI-DC-UPS/24DC/2

2866640

1

MINI-DC-UPS/12DC/4

2866598

1

301

PHOENIX CONTACT

MINI-UPS 24 V DC and 12 V DC

The MINI UPS combines the power 

supply and the UPS module in the same 
housing in a particularly space-saving way.

Notes:

With the MINI-DC-UPS/12DC/4, buffer times are double those of 

the MINI-DC-UPS/24DC/2.

The buffer time associated with your solution is dependent on the 

load current. Exact details for each uninterruptible power supply 

can be found on page 293.

H

W

D

H

W

D

UPS module with integrated power 
supply

Power supplies and UPS

Uninterruptible power supplies

UPS with integrated power supply,

100 - 240 V AC / 24 V DC, 2 A

UPS with integrated power supply,

100 - 240 V AC / 12 V DC, 4 A

phoenixcontact-protection-html.html
background image

Ex: 

Technical data

Input data/output data

Nominal capacity

1.3 Ah

Nominal output voltage

24 V DC

Output current

15 A

Can be connected in parallel/series

Yes / No

General data

Weight / Dimensions W x H x D

1.7 kg / 52 x 130 x 110 mm

3.5 kg / 112 x 145 x 123 mm

6 kg / 164 x 156 x 110 mm

9 kg / 231 x 156 x 1

Degree of protection / Protection class

IP20 / III

Ambient temperature (operation)

0 °C ... 40 °C

Service life

6 years ... 9 years (20 °C)

6 years ... 9 years (20 °C)

6 years ... 9 years (20 °C)

6 years ... 9 years (20 °C)

Latest startup

6 months (20 °C ... 30 °C)

3 months (30 °C ... 40 °C)

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Energy storage

MINI-BAT/24DC/1.3AH

2866417

1

Accessories

Fuse

FUSE 15A/32V FKS ATO

2908361

2

302

PHOENIX CONTACT

Energy storage for TRIO UPS

MINI-BAT, QUINT-BAT

MINI-BAT and QUINT BAT for maximum 

buffer times
– Lead AGM (Absorbent Glass Mat) 

technology

– Ambient temperatures from 0 to +40°C

Power supplies and UPS

Uninterruptible power supplies

H

W

D

Energy storage, 24 V DC, 1.3 Ah

for TRIO UPS and MINI UPS 2 A

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

Technical data

Technical data

Technical data

3.4 Ah

7.2 Ah

12 Ah

24 V DC

24 V DC

24 V DC

25 A

50 A

50 A

Yes / No

Yes / No

Yes / No

Weight / Dimensions W x H x D

1.7 kg / 52 x 130 x 110 mm

3.5 kg / 112 x 145 x 123 mm

6 kg / 164 x 156 x 110 mm

9 kg / 231 x 156 x 110 mm

IP20 / -

IP20 / III

IP20 / III

0 °C ... 40 °C

0 °C ... 40 °C

0 °C ... 40 °C

Service life

6 years ... 9 years (20 °C)

6 years ... 9 years (20 °C)

6 years ... 9 years (20 °C)

6 years ... 9 years (20 °C)

9 months (20 °C ... 30 °C)

6 months (30 °C ... 40 °C)

9 months (20 °C ... 30 °C)

6 months (30 °C ... 40 °C)

9 months (20 °C ... 30 °C)

6 months (30 °C ... 40 °C)

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

QUINT-BAT/24DC/ 3.4AH

2866349

1

QUINT-BAT/24DC/ 7.2AH

2866352

1

QUINT-BAT/24DC/12AH

2866365

1

Accessories

Accessories

Accessories

FUSE 25A/32V ATOF

2908366

2

FUSE 25A/32V ATOF

2908366

2

FUSE 25A/32V ATOF

2908366

2

303

PHOENIX CONTACT

Power supplies and UPS

Uninterruptible power supplies

H

W

D

H

W

D

H

W

D

Energy storage, 24 V DC, 3.4 Ah

for TRIO UPS

Energy storage, 24 V DC, 7.2 Ah

for TRIO UPS

Energy storage, 24 V DC, 12 Ah

for TRIO UPS

phoenixcontact-protection-html.html
background image

Ex: 

Technical data

Input data/output data

Nominal capacity

0.8 Ah

Nominal output voltage

24 V DC

Output current

5 A

Can be connected in parallel/series

Yes / No

General data

Weight / Dimensions W x H x D

0.9 kg / 67.5 x 99 x 107 mm

1.7 kg / 52 x 130 x 110 mm

0.9 kg / 67.5 x 99 x 107 mm

1.7 kg / 52 x 130 

Degree of protection / Protection class

IP20 / III

Ambient temperature (operation)

0 °C ... 40 °C

Service life

4 years (20 °C)

Latest startup

6 months (20 °C ... 30 °C)

3 months (30 °C ... 40 °C)

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Energy storage

MINI-BAT/24DC/0.8AH

2866666

1

Accessories

Fuse

FUSE  5A/32V FK-1

2908367

2

304

PHOENIX CONTACT

Energy storage for MINI UPS

MINI-BAT

MINI-BAT for maximum buffer times

– Lead AGM (Absorbent Glass Mat) 

technology

– Ambient temperatures from 0 to +40°C

Power supplies and UPS

Uninterruptible power supplies

H

W

D

Notes:

The buffer time associated with your solution is dependent on the 

load current. Exact details for each uninterruptible power supply 

can be found on page 293.

Energy storage, 24 V DC, 0.8 Ah

for MINI UPS 2 A

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Ex: 

Ex: 

Ex: 

Technical data

Technical data

Technical data

1.3 Ah

1.6 Ah

2.6 Ah

24 V DC

12 V DC

12 V DC

15 A

10 A

15 A

Yes / No

Yes / No

Yes / No

Weight / Dimensions W x H x D

0.9 kg / 67.5 x 99 x 107 mm

1.7 kg / 52 x 130 x 110 mm

0.9 kg / 67.5 x 99 x 107 mm

1.7 kg / 52 x 130 x 110 mm

IP20 / III

IP20 / III

IP20 / III

0 °C ... 40 °C

0 °C ... 40 °C

0 °C ... 40 °C

6 years ... 9 years (20 °C)

4 years (20 °C)

6 years ... 9 years (20 °C)

6 months (20 °C ... 30 °C)

3 months (30 °C ... 40 °C)

6 months (20 °C ... 30 °C)

3 months (30 °C ... 40 °C)

6 months (20 °C ... 30 °C)

3 months (30 °C ... 40 °C)

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

MINI-BAT/24DC/1.3AH

2866417

1

MINI-BAT/12DC/1.6AH

2866572

1

MINI-BAT/12DC/2.6AH

2866569

1

Accessories

Accessories

Accessories

FUSE 15A/32V FKS ATO

2908361

2

FUSE 10A/32V  FK1

2908364

2

FUSE 25A/32V FKS

2908363

2

305

PHOENIX CONTACT

Power supplies and UPS

Uninterruptible power supplies

H

W

D

H

W

D

H

W

D

Energy storage, 24 V DC, 1.3 Ah

for TRIO UPS and MINI UPS 2 A

Energy storage 12 V DC, 1.6 Ah

for MINI UPS 4 A

Energy storage 12 V DC, 2.6 Ah

for MINI UPS 4 A

phoenixcontact-protection-html.html
background image

306

PHOENIX CONTACT

phoenixcontact-protection-html.html
background image

 

Basics

 308

 

 

Multi-channel device circuit breakers

 310

 

 

Selection guide

 312

 

 

Applications

 313

 

 

CBM electronic circuit breakers

 314

 

 

CBMC electronic circuit breakers

 316

 

 

Single-channel device circuit breakers

 318

 

 

Selection guide

 320

 

 

Applications

 321

 

 

Electronic circuit breakers

 322

 

 

Thermomagnetic circuit breakers

 328

 

 

Thermal circuit breakers

 334

 

307

PHOENIX CONTACT

High-quality device circuit breakers 
provide optimum system protection

Thermomagnetic and electronic device 

circuit breakers are a key factor in 
maximizing system availability. In the event 
of overload and short-circuit currents, they 
selectively shut down the faulty circuit.

Your web code: 

#0156

Device circuit breakers

phoenixcontact-protection-html.html
background image

308

PHOENIX CONTACT

Why device circuit breakers?

Overload currents and short-circuit 

currents are usually unexpected. They cause 
malfunctions and interruptions to the 
ongoing operation of a system. Production 
downtimes and repair costs can often be 
the unfortunate consequences.

Minimize damage by protecting individual 

devices or device groups separately. In this 
way, terminal devices are optimally 
protected against damage or destruction. 
System parts which are not in the affected 
circuit continue to operate without 
interruption, insofar as the overall process 
allows.

Overload currents

Overload currents occur if terminal 

devices unexpectedly require a higher 
current than the rated current provided. 
Such situations may arise, for example, due 
to a blocked drive. Temporary starting 
currents from machines are also considered 
to be overload currents. The occurrence of 
these can essentially be calculated, but 
nonetheless can vary depending upon the 
machine load at the moment it starts.

When selecting suitable fuses or circuit 

breakers for such circuits, these conditions 
should be taken into account. Safe 
shutdown should occur in the seconds to 
minute range.

Short-circuit currents

Short circuits may occur in the case of 

damage to the insulation between 
conductors, which carry operating voltage. 
Typical protective devices for shutting down 
short-circuit currents include fuses or 
miniature circuit breakers with various 
tripping mechanisms.

Short-circuit currents should be reliably 

shut down in the milliseconds range.

Selecting the right device circuit 
breakers

The demands placed on optimum device 

protection vary depending on the area of 
application. Device circuit breakers 
therefore work with a wide range of 
technologies: electronic, thermal, and 
thermomagnetic. The differences are in the 
tripping technology and shutdown behavior 
used. Characteristic curves clearly illustrate 
the switch-off characteristics of the various 
device circuit breakers.

Device circuit breakers are selected based 

on the nominal voltage, nominal current, 
and, if required, the starting current of a 
terminal device. The expected error 
situation (short circuit or overload) then 
determines the appropriate shutdown 
behavior.

Your web code: 

#1253

Device circuit breakers

Basics

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

309

PHOENIX CONTACT

The right protection for a circuit

The right choice of protective device 

ensures safe operation of electrical systems 
and high system availability.

Circuit breakers protect current 

distribution cables in buildings or systems. It 
is only in the event of a short circuit in a 
terminal device that they switch off to 
protect the power supply line in the event 
of overload. The circuit breakers have a high 
switching capacity of upwards of 6 kA.

As the last protection stage for terminal 

devices, thermomagnetic and electronic 
circuit breakers offer the most effective 
short-circuit and overload protection. If 
individual loads or small function groups are 
protected individually, then unaffected 
system parts can continue to work in the 
event of an error, insofar as the overall 
process allows.

If a new circuit is installed, appropriate 

protection for the terminal device provided 
must be sought immediately. During 
installation, cable lengths and conductor 
cross sections must also be observed. The 
cables must be designed for the expected 
operating current, but should also be able 
to deal with any potential overload and 
short-circuit currents. Within the scope of 
graded protection of system areas, the 
selectivity between the individual fuses or 
protective devices must be retained. This 
ensures higher system availability as only the 
faulty circuit is switched off.

It is advisable to make device circuit 

breakers easily accessible when installed in 
control cabinets so that they can be 
switched on again quickly and without 
problems after tripping. In addition, a 
control cabinet should not contain too 
many components, as this can cause an 
overload in the power supply. Furthermore, 
a sufficient air flow and cooling process 
should be ensured. This enables incorrect 
tripping to be prevented.

Influence of cable lengths on 
shutdown behavior

In the event of an error, long cable paths 

limit the required tripping current. They can 
delay or even prevent shutdown.

The maximum cable lengths that can be 

used between a power supply and a terminal 
device are defined by the following criteria:
–     The maximum current of the power 

supply

–     The internal resistance of the circuit 

breaker

–     The cable resistance

The cable resistance is dependent on the 

cable length and conductor cross section. 
For this reason, as a general rule, the 
shortest cable path should be selected 
during installation.

 The length and cross section determine 

the switch-off conditions for a device circuit 
breaker.

Cable resistance counteracts a short-

circuit current. In the event of low voltage 
sources, a short-circuit current can be 
limited by the cable resistance in such a way 
that safety equipment no longer recognizes 
this current as a short-circuit current. In the 
case of circuit breakers with C 
characteristics, for example, the upper 
tripping limit is significantly higher than the 
nominal current. For this reason, a delayed 
shutdown is highly likely in the event of a 
short circuit when using this safety 
equipment.

Optimized protective devices with SFB 

characteristics or active current limitation 
detect at an early stage whether the 
nominal current has been exceeded.

Device circuit breakers

Basics

phoenixcontact-protection-html.html
background image

310

PHOENIX CONTACT

Device circuit breakers

Multi-channel device circuit breakers

Multi-channel electronic circuit 
breakers

Safely protect against overload and short-

circuit currents in a space-saving way. 
Thanks to multi-channel device circuit 
breakers, you can protect multiple circuits 
with just one single device, even in confined 
spaces. All channels can be individually 
adjusted and can therefore be adjusted as 
required to the connected loads. An 
integrated electronic interlock secures and 
protects the parameters you have set from 
unwanted changes. Push-in connection 
technology enables quick and tool-free 
installation of the devices.

All devices provide constant status checks 

on the individual channels. The multi-stage 
status indicator reliably informs you of the 
current status of the circuit. An early 
warning is also emitted that indicates 
utilization over 80%. All devices also have a 
remote indication contact.

Thanks to electronic tripping in the event 

of a short circuit, the faulty channels are 
switched off particularly quickly and 
precisely.

CBMC compact device circuit breaker

With the compact device circuit breakers, 

you can protect four channels with just one 
device. The product range offers two 
versions with setting options for the 
nominal current from 1 A to 4 A or 1 A to 
10 A. The 1-4 A version provides optimum 
protection for cables and sensors as well as 
NEC class 2 circuits by means of an adjusted 
internal output fuse.

The device circuit breakers can be 

ordered preconfigured. This means the 
devices are tailored exactly to your system 
and can be installed and connected directly.

CBM highly functional device circuit 
breaker

The CBM device circuit breakers protect 

four or eight channels. Both devices protect 
nominal currents up to 10 A. A nominal 
current assistant helps you to correctly 
adjust the channels and makes installation 
especially easy. The CBM has a Reset IN 
connection, so that disconnected channels 
can be switched back on again remotely. 
Furthermore, the device provides the 
option of signaling utilization over 80% via 
the remote indication contact.

Thanks to the active current limitation, 

the current does not exceed a set threshold 
value in the event of a short circuit. This 
reduces the load on the power supply, 
thereby preventing a voltage drop.

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

311

PHOENIX CONTACT

Device circuit breakers

Multi-channel device circuit breakers

Incremental adjustment

The multi-channel electronic circuit 

breakers have fine nominal current grading. 
The CBM can be adjusted in increments 
from 0.5 A to 10 A, the CBMC from 1 A to 
4 A or 10 A, and set individually to the 
nominal currents of the connected terminal 
devices.

Fast connection

Easy and tool-free direct plug-in. Push-in 

connection technology enables easy and 
direct insertion of solid and stranded 
conductors without the need for great 
force.

Easy to configure

Configuring the CBM could not be easier 

with the new nominal current assistant. It 
enables optimal adjustment of the load 
currents.

Analysis and signaling

The currents flowing are constantly 

monitored. As such, the CBM not only 
provides the floating signal contact, but also 
an 80% output. Consequently, you receive a 
message when at least one channel is heavily 
overloaded. The disconnected channel can 
then be easily switched back on remotely via 
the Reset IN signal input.

Very compact

The CBMC protects four circuits against 

overload and short-circuit currents on just 
36 mm. Thanks to adjustable nominal 
currents of 1 A to 4 A or 10 A in a single 
device, storage costs are reduced while 
simultaneously increasing flexibility for 
system planning.

Can be ordered preconfigured

Order the CBMC device circuit breaker 

that is already configured for your system. 
This means the device can be used 
immediately, without further configuration 
effort. The preconfigured devices are also 
available with fixed, preprogrammed 
nominal current values.

phoenixcontact-protection-html.html
background image

312

PHOENIX CONTACT

CMB circuit breakers

24 V DC

24 V DC

0.5 A ... 10 A

0.5 A ... 10 A

4 channels

8 channels

Page 314

Page 314

CBMC circuit breakers

24 V DC

24 V DC

24 V DC

24 V DC

1 A ... 4 A

1 A ... 10 A

1 A ... 4 A

1 A ... 10 A

4 channels

4 channels

4 channels

4 channels

Can be ordered preconfigured

Can be ordered preconfigured

Page 316

Page 316

Page 317

Page 317

Selection guide

Device circuit breakers

Multi-channel device circuit breakers

phoenixcontact-protection-html.html
background image

1

3

14

DC O

K

2

4-

2

8V

+

+

-

-

-

L / +

N

 / -

I

nput

100-

2

40V

AC

O

utput

2

4V 

2

0A

DC

L

N

P

E

I

N

+

I

N

-

DC O

K

SIG

N

ALS

OUT+

1

2

3

4

5

6

7

8

1

3

14

1

2

1

2

1

2

3

4

5

6

7

8

RST

I >
80%

1

0,

5

2

4

6

10

1

0,

5

2

4

6

10

1

0,

5

2

4

6

10

1

0,

5

2

4

6

10

1

0,

5

2

4

6

10

1

0,

5

2

4

6

10

1

0,

5

2

4

6

10

1

0,

5

2

4

6

10

+

I>80%

N

FC

QUINT P

O

WER

U

O

ut

29,5V

24V

13
14

Rem

SGnd

O

ut 1

O

ut 2

Signal

> 100% Boost
> 75%
> 50%

DC 

O

K

Input AC 100-240 V

N/- L/+

O

utput DC 24V 10A

+

+

-

-

-

C

B

M

C

1

2

I

N

+

1

2

3

4

1

2

3

4

1

3

14

1

2

I

N

-

OUT+

N

P

E

L

+

For further information and full technical data, visit phoenixcontact.net/products

313

PHOENIX CONTACT

Applications

CBM device circuit breakers

CBM

Page 314

CBMC device circuit breakers

CBMC

Page 316

Reset

Group 

message

Group 

message

Device circuit breakers

Multi-channel device circuit breakers

phoenixcontact-protection-html.html
background image

t

x I

N

0,

5

1000

100

10

1

0,1

0,01

2

1,

3

1,

5

0,

5

 ... 1 A

s

1,1

t

x I

N

0,

5

1000

100

10

1

0,1

0,01

2

1,

3

1,

5

2

 ... 10 A

s

1,1

 

 

Ex: 

 

 

 

Ex: 

 

Technical data

Technical data

Electrical data

Rated voltage

24 V DC

24 V DC

Rated current I

N

max. 40 A DC

max. 80 A DC (for double supply IN+ with at least 2 x 6 mm²)

Rated current I

N

0.5

 

/

 

1

 

/

 

2

 

/

 

4

 

/

 

6

 

/

 

10

 

A DC

 

(adjustable per output channel)

0.5

 

/

 

1

 

/

 

2

 

/

 

4

 

/

 

6

 

/

 

10

 

A DC

 

(adjustable per output channel)

Switch-on delay

0.1 s (per output channel)

0.1 s (per output channel)

Max. capacitive load

75000 µF (per channel at 24

 

V

 

DC)

75000 µF (per channel at 24

 

V

 

DC)

Internal output fuse

15 A DC (per output channel)

15 A DC (per output channel)

Active current limitation

Typ. 2.0 x I

(0.5 - 1

 

A) / Typ. 1.5 x I

(2 - 10 A)

Typ. 2.0 x I

(0.5 - 1

 

A) / Typ. 1.5 x I

(2 - 10 A)

Load circuit

Shutdown time

0.02 s (> 1.3 x I

N

) / 30 s (1.1 ... 1.3 x I

N

)

0.02 s (> 1.3 x I

N

) / 30 s (1.1 ... 1.3 x I

N

)

Reset input

Input voltage range

7 V DC ... 30 V DC (Falling edge)

7 V DC ... 30 V DC (Falling edge)

General data

Dimensions W/H/D

41 mm / 130 mm / 121 mm

41 mm / 130 mm / 121 mm

Ambient temperature (operation)

-25 °C ... 70 °C (Startup at -40

 

C type-tested)

-25 °C ... 70 °C (Startup at -40

 

C type-tested)

Standards/regulations

EN 61000-6-2 / EN 61000-6-3 / EN

 

60068-2-6 / EN 60068-2-11

EN 61000-6-2 / EN 61000-6-3 / EN

 

60068-2-6 / EN 60068-2-11

Remote indication contact

DC operating voltage

0 V DC ... 30 V DC

0 V DC ... 30 V DC

DC operating current

1 mA DC ... 100 mA

1 mA DC ... 100 mA DC

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Circuit breaker

CBM E4 24DC/0.5-10A NO-R

2905743

1

CBM E8 24DC/0.5-10A NO-R

2905744

1

314

PHOENIX CONTACT

Tripping characteristic in the DC range 

Tripping characteristic in the DC range 

Device circuit breakers

Multi-channel device circuit breakers

DIN-rail-mountable,

4-channel

DIN-rail-mountable,

8-channel

– For protection against voltage dips caused 

by overload and short circuit

– Adjustable from 0.5 - 10 A
– Integrated dynamic current limitation
– Supply up to 80 A possible
– Slim  design

Notes:

For additional technical data, drawings, and accessories, please 

visit phoenixcontact.net/products.

CBM electronic circuit breakers

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

315

PHOENIX CONTACT

Device circuit breakers

Multi-channel device circuit breakers

phoenixcontact-protection-html.html
background image

1000

100

10

1

0,1

0,01

t

s

0,

5

2

1,

2

1

x I

N

1000

100

10

1

0,1

0,01

t

s

0,

5

2

1,

2

1

x I

N

 

 

 

 

Technical data

Technical data

Electrical data

Rated voltage

24 V DC

24 V DC

Rated current I

N

max. 16 A DC

max. 40 A DC

Rated current I

N

1

 

/

 

2

 

/

 

3

 

/

 

4

 

A DC

 

(adjustable per output channel)

1

 

/

 

2

 

/

 

3

 

/

 

4

 

/

 

5

 

/

 

6

 

/

 

7

 

/

 

8

 

/

 

9

 

/

 

10

 

A DC

 

(adjustable per output channel)

Switch-on delay

0.1 s (Cascaded per output channel)

0.1 s (Cascaded per output channel)

Max. capacitive load

30000 µF (Depending on the current setting and the short-circuit 

current available)

45000 µF (Depending on the current setting and the short-circuit 

current available)

Internal output fuse

4 A DC (per output channel)

15 A DC (per output channel)

Active current limitation

-

-

Load circuit

Shutdown time

 10 ms (for short circuit > 2.0 x I

N

) / 1 s (1.2 ... 2.0 x I

N

)

 10 ms (for short circuit > 2.0 x I

N

) / 1 s (1.2 ... 2.0 x I

N

)

General data

Dimensions W/H/D

36 mm / 90 mm / 98 mm

36 mm / 90 mm / 98 mm

Ambient temperature (operation)

-25 °C ... 60 °C

-25 °C ... 60 °C

Standards/regulations

EN 61000-6-2 / EN 61000-6-3 / EN 60068-2-78 / UL 508

EN 61000-6-2 / EN 61000-6-3 / EN 60068-2-78 / UL 508

Remote indication contact

DC operating voltage

0 V DC ... 30 V DC

0 V DC ... 30 V DC

DC operating current

100 mA DC

100 mA DC

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Circuit breaker

CBMC E4 24DC/1-4A NO

2906031

1

CBMC E4 24DC/1-10A NO

2906032

1

316

PHOENIX CONTACT

Tripping characteristic in the DC range 

Tripping characteristic in the DC range 

Device circuit breakers

Multi-channel device circuit breakers

DIN-rail-mountable,

4-channel

DIN-rail-mountable,

4-channel

– For protection against voltage dips caused 

by overload and short circuit

– Adjustable in 1 A increments up to 

max. 10 A

– Compact  design
– Suitable for NEC class 2 applications

Notes:

For additional technical data, drawings, and accessories, please 

visit phoenixcontact.net/products.

new

new

CBMC electronic circuit breakers

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

Technical data

Technical data

Electrical data

Rated voltage

24 V DC

24 V DC

Rated current I

N

max. 16 A DC

max. 40 A DC

Rated current I

N

1

 

/

 

2

 

/

 

3

 

/

 

4

 

A DC

 

(Adjustable or fixed per output channel)

1

 

/

 

2

 

/

 

3

 

/

 

4

 

/

 

5

 

/

 

6

 

/

 

7

 

/

 

8

 

/

 

9

 

/

 

10

 

A DC

 

(Adjustable or fixed per output 

channel)

Switch-on delay

0.1 s (Cascaded per output channel)

0.1 s (Cascaded per output channel)

Max. capacitive load

30000 µF (Depending on the current setting and the short-circuit 

current available)

45000 µF (Depending on the current setting and the short-circuit 

current available)

Internal output fuse

4 A DC (per output channel)

15 A DC (per output channel)

Active current limitation

-

-

Load circuit

Shutdown time

 10 ms (for short circuit > 2.0 x I

N

) / 1 s (1.2 ... 2.0 x I

N

)

 10 ms (for short circuit > 2.0 x I

N

) / 1 s (1.2 ... 2.0 x I

N

)

General data

Dimensions W/H/D

36 mm / 90 mm / 98 mm

36 mm / 90 mm / 98 mm

Ambient temperature (operation)

-25 °C ... 60 °C

-25 °C ... 60 °C

Standards/regulations

EN 61000-6-2 / EN 61000-6-3 / EN 60068-2-78 / UL 508

EN 61000-6-2 / EN 61000-6-3 / EN 60068-2-78 / UL 508

Remote indication contact

DC operating voltage

0 V DC ... 30 V DC

0 V DC ... 30 V DC

DC operating current

100 mA DC

100 mA DC

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Circuit breaker

CBMC E4 24DC/1-4A NO-C

2908713

1

CBMC E4 24DC/1-10A NO-C

2908716

1

317

PHOENIX CONTACT

Device circuit breakers

Multi-channel device circuit breakers

DIN-rail-mountable,

4-channel, preconfigurable

DIN-rail-mountable,

4-channel, preconfigurable

new

new

Order key for the device circuit breaker: 
CBMC E4 24DC/1-4A NO-C

Order key for the device circuit breaker: 
CBMC E4 24DC/1-10A NO-C

Order No.

Adjustability

Channel 

1

Channel 

2

Channel 

3

Channel 

4

Order No.

Adjustability

Channel 

1

Channel 

2

Channel 

3

Channel 

4

2908713

/

ADJ

/

1

/

3

/

1

/

4

2908716

/

ADJ

/

1

/

5

/

8

/

10

Select the current value in amperes individually 

for each channel

1 ... 4

Select the current value in amperes individually 

for each channel

1 ... 10

ADJ – adjustable

ADJ – adjustable

FIX – not adjustable

FIX – not adjustable

phoenixcontact-protection-html.html
background image

318

PHOENIX CONTACT

Device circuit breakers

Single-channel device circuit breakers

Branch out

The device circuit breakers provide 

reliable protection even in systems with 
long cable paths. Together with the SFB 
Technology* of the QUINT POWER power 
supplies, the special SFB tripping 
characteristic of the CB device circuit 
breakers ensures fast shutdown in the event 
of an error. This combination offers 
maximum protection against overload and 
short-circuit currents.

*SFB = Selective Fuse Breaking, selective 

shutdown

Modular extension

It couldn't be easier. A system can be 

extended with additional device circuit 
breakers in no time at all. You can bridge the 
power distribution, remote signaling or 
even the auxiliary voltage for electronic 
circuit breakers without this resulting in 
significant wiring costs. The uniform, plug-in 
housing concept as well as the bridgeability 
of the base elements simplify installation.

Individual adaptation

Systems and control cabinets can be pre-

wired with base elements and individually 
fitted with corresponding protective plugs 
on site. Should the demands on a load 
change in the meantime, you can simply 
replace the protective plug in question. 
Various tripping methods, tripping 
characteristics, and nominal currents are 
available depending on the application.

phoenixcontact-protection-html.html
background image

I

_

A

15 x l

N

15 x l

N

10 x l

N

4 x l

N

2 x l

N

6 x l

N

12 x l

N

1 x l

N

l

N

0

For further information and full technical data, visit phoenixcontact.net/products

319

PHOENIX CONTACT

Device circuit breakers

Single-channel device circuit breakers

Latching

The new locking mechanism ensures a 

secure hold in harsh environments and 
where there are vibrations in the 
installation environment. It holds the plug 
securely in the base element. The plugs can 
be removed from the base element quickly 
and easily by simply applying light pressure 
to the locking mechanism.

Bridge

With the unique bridge system from our 

standard range, the device circuit breakers 
can be combined easily as per your 
requirements. Potentials of the same type 
can be connected quickly and safely.

Variable connection technologies

Base elements are available with 

conventional screw connection technology 
or quick-to-wire Push-in connection 
technology.

SFB tripping characteristic

Thermomagnetic device circuit breakers 

with the SFB tripping characteristic* 
provide maximum overcurrent protection – 
even in large systems with long cable paths.

Active current limitation

The active current limitation of electronic 

device circuit breakers restricts short-
circuit and overload currents to a value that 
is 1.25 to 2 times the nominal current. This 
protects the power supply against 
excessively high currents and prevents the 
output voltage dipping at the switched-
mode power supply unit. In addition, longer 
cable paths between the power supply and 
load are possible without negatively 
impacting the shutdown behavior.

F

a

st shutdown

M1 ch

a

r

a

cteristic curve

SFB ch

a

r

a

cteristic curve

F1 ch

a

r

a

cteristic curve

Electronic ch

a

r

a

cteristic

curve

phoenixcontact-protection-html.html
background image

320

PHOENIX CONTACT

Selection guide

Electronic device circuit breakers

CB E1

ECP-E

ECP

EC-E

24 V DC

24 V DC

24 V DC

24 V DC

1 A ... 10 A

1 A ... 12 A

1 A ... 10 A

0.5 A ... 12 A

Page 322

Page 324

Page 325

Page 326

Thermomagnetic device circuit breakers

CB TM

UT6-TMC

TMC

50 V DC

277 V AC

28 V DC

240 V AC

65 V DC

250 V AC

0.5 A ... 16 A

0.5 A ... 16 A

0.2 A ... 16 A

Page 328

Page 332

Page 333

Thermal device circuit breakers

TCP.../DC

TCP

32 V DC

65 V DC

250 V AC

5 A ... 40 A

0.25 A ... 10 A

Page 334

Page 335

Device circuit breakers

Single-channel device circuit breakers

phoenixcontact-protection-html.html
background image

N

FC

QUINT P

O

WER

U

O

ut

29,5V

24V

13
14

Rem

SGnd

O

ut 1

O

ut 2

Signal

> 100% Boost
> 75%
> 50%
DC 

O

K

Input AC 100-240 V

N/- L/+

O

utput DC 24V 10A

+

+

-

-

-

2

3

0 V

F2

F1

F3

F4

F5

F5

F6

F6

10A

F

8

10A

F7

F1

F2

F3

F4

N

FC

QUINT P

O

WER

U

O

ut

29,5V

24V

13
14

Rem

SGnd

O

ut 1

O

ut 2

Signal

> 100% Boost
> 75%
> 50%
DC 

O

K

O

utput DC 24V 10A

+

+

Input AC 100-240 V

N/- L/+

N

P

E

L

R

eset

S

t

a

tus

For further information and full technical data, visit phoenixcontact.net/products

321

PHOENIX CONTACT

Protecting 24 V loads

CB E1...

CB-TM1...

TCP...

UT 6-TMC...

Page 322

Page 328

Page 335

Page 332

Enhanced functionality through digital signals

CB E1...

Page 322

Applications

Device circuit breakers

Single-channel device circuit breakers

phoenixcontact-protection-html.html
background image

0

1

0

1

0

,

1

0

,

0

1

1

00

1

000

1

2

3

12,3

90

4

0

,

7

45

77

,3

 

 

 

Total width 12.3 mm

Technical data

Electrical data

Operating voltage

24 V DC

Nominal current I

N

Depends on the product version selected

Depends on the product version selected

Depends on the product version selected

Depends on

Disconnection

Switch-off time

See tripping characteristic

See tripping characteristic

See tripping characteristic

See tripping characteristic

Active current limitation

typ. 1.25 x I

N

General data

Ambient temperature (operation)

-25 °C ... 50 °C (non-condensing)

-

Degree of protection

IP30 (Actuation area)

Standards/regulations

UL 2367 / UL 508 / EN 61000-6-3 / EN 61000-6-2

UL 2367 / UL 508 / EN 61000-6-3 / EN 61000-6-2

UL 2367 / UL 5

Ordering data

Description

Nominal

current

Type

Order No.

Pcs./Pkt.

Electronic circuit breaker,

 1-pos.

1 A

CB E1 24DC/1A NO P

2800901

1

2 A

CB E1 24DC/2A NO P

2800902

1

3 A

CB E1 24DC/3A NO P

2800903

1

4 A

CB E1 24DC/4A NO P

2800904

1

6 A

CB E1 24DC/6A NO P

2800905

1

8 A

10 A

Accessories

Bridge plug,

 0 volt distribution

CB PT BRIDGE

2801014

1

Base element

With Push-in connection technology

CB 1/6-2/4 PT-BE

2800929

10

With screw connection technology

CB 1/10-1/10 UT-BE

2801305

10

For the PCB

CB S-BE

2905067

30

Plug-in bridge, for cross connections in the bridge shaft

For FBS ..., see page 331

322

PHOENIX CONTACT

Plug-in electronic circuit breakers

Switching

time

[s]

Multiples of I

N

– Device circuit breakers for protecting 

against voltage dips caused by overloads 
and short circuits

– Integrated active current limitation
– Remote control possible
– Maximum ease of maintenance thanks to 

the two-piece design

– Snap-in function for secure hold and easy 

removal

– Plug coding possible
– Slim  design

Notes:

In conjunction with order number

2800929

 and 

2801305

, the 

items also satisfy UL 508.

For additional technical data, drawings, and accessories, please 

visit phoenixcontact.net/products.

Tripping characteristic

Device circuit breakers

Single-channel device circuit breakers

1 N/O contact

1 N/C contact

1 x Status OUT + 1 x Reset IN

1 x Status OUT + 1 x Control IN

The figure shows the complete module consisting of a base 

element and plug

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

Total width 12.3 mm

Total width 12.3 mm

Total width 12.3 mm

Technical data

Technical data

Technical data

24 V DC

24 V DC

24 V DC

Depends on the product version selected

Depends on the product version selected

Depends on the product version selected

Depends on the product version selected

Switch-off time

See tripping characteristic

See tripping characteristic

See tripping characteristic

See tripping characteristic

typ. 1.25 x I

N

typ. 1.25 x I

N

typ. 1.25 x I

N

Ambient temperature (operation)

-25 °C ... 50 °C (non-condensing)

-25 °C ... 50 °C (non-condensing)

-25 °C ... 50 °C (non-condensing)

-25 °C ... 50 °C (non-condensing)

IP30 (Actuation area)

IP30 (Actuation area)

IP30 (Actuation area)

Standards/regulations

UL 2367 / UL 508 / EN 61000-6-3 / EN 61000-6-2

UL 2367 / UL 508 / EN 61000-6-3 / EN 61000-6-2

UL 2367 / UL 508 / EN 61000-6-3 / EN 61000-6-2

UL 2367 / UL 508 / EN 61000-6-3 / EN 61000-6-2

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

CB E1 24DC/1A NC P

2800915

1

CB E1 24DC/1A S-R P

2800908

1

CB E1 24DC/1A S-C P

2800922

1

CB E1 24DC/2A NC P

2800916

1

CB E1 24DC/2A S-R P

2800909

1

CB E1 24DC/2A S-C P

2800923

1

CB E1 24DC/3A NC P

2800917

1

CB E1 24DC/3A S-R P

2800910

1

CB E1 24DC/3A S-C P

2800924

1

CB E1 24DC/4A NC P

2800918

1

CB E1 24DC/4A S-R P

2800911

1

CB E1 24DC/4A S-C P

2800925

1

CB E1 24DC/6A NC P

2800919

1

CB E1 24DC/6A S-R P

2800912

1

CB E1 24DC/6A S-C P

2800926

1

CB E1 24DC/8A S-R P

2800913

1

CB E1 24DC/8A S-C P

2800927

1

CB E1 24DC/10A S-R P

2800914

1

CB E1 24DC/10A S-C P

2800928

1

Accessories

Accessories

Accessories

CB PT BRIDGE

2801014

1

CB PT BRIDGE

2801014

1

CB PT BRIDGE

2801014

1

CB 1/6-2/4 PT-BE

2800929

10

CB 1/6-2/4 PT-BE

2800929

10

CB 1/6-2/4 PT-BE

2800929

10

CB 1/10-1/10 UT-BE

2801305

10

CB 1/10-1/10 UT-BE

2801305

10

CB 1/10-1/10 UT-BE

2801305

10

CB S-BE

2905067

30

CB S-BE

2905067

30

CB S-BE

2905067

30

For FBS ..., see page 331

For FBS ..., see page 331

For FBS ..., see page 331

323

PHOENIX CONTACT

Device circuit breakers

Single-channel device circuit breakers

1 N/O contact

1 N/C contact

1 x Status OUT + 1 x Reset IN

1 x Status OUT + 1 x Control IN

phoenixcontact-protection-html.html
background image

2

12

14

13

11

1

C

ont

r

o

l

 

U

nit

LINE (+)

R

eset

S

t

a

tus

R

eset

L

O

A

D

 (L+)

G

N

D

 (-)

O

n

/O

ff

0

,

0

1

0

,

1

1

1

0

1

0

2

1

0

3

1

0

4

5

1

0

2

3

I

K

 

Ex: 

 

Total width 12.5 mm

Technical data

Electrical data

Operating voltage

24 V DC

Nominal current I

N

Depends on the product version selected

Depends on the product version selected

Depends on the product version selected

Depends on

Disconnection

Switch-off time

See tripping characteristic

See tripping characteristic

See tripping characteristic

See tripping characteristic

Switch off

Typ. 1.8 x I

N

Active current limitation

active 

General data

Temperature range

0 °C ... 50 °C (non-condensing)

0 °C ... 50 °C 

Degree of protection

IP30 (Actuation area)

Standards/regulations

UL 2367 / UL 508 / CSA 22.2

UL 2367 / UL 508 / CSA 22.2

UL 2367 / UL 508 / CSA 22.2

-

Ordering data

Description

Nominal

current

Type

Order No.

Pcs./Pkt.

Electronic circuit breaker,

 can be plugged into TMCP base, 

signaling via LED

1 A

ECP-E  1A

0900113

5

2 A

ECP-E  2A

0900210

5

3 A

ECP-E  3A

0900317

5

4 A

ECP-E  4A

0900414

5

6 A

ECP-E  6A

0900618

5

8 A

ECP-E  8A

0900812

5

10 A

ECP-E 10A

0901002

5

12 A

ECP-E-12A

0900126

5

Electronic circuit breaker,

 as above, but nominal current can be 

set via a switch, 1

 

A and 2

 

A

1 A

(adjustable)

Electronic circuit breaker,

 as above, but nominal current can be 

set via a switch, 3

 

A and 6

 

A

3 A

(adjustable)

Accessories

Spring lock, 

 for mechanical locking in the case of overhead 

mounting, 1-pos.

SPRING-LOCK

0713009

10

Modular socket, 

2-position, for holding two circuit breakers, each 

with a single position

TMCP SOCKET M

0916589

10

Socket termination elements,

 can be plugged in both left and 

right, contain the connections for the reset inputs/group query

TMCP CONNECT LR

0916592

3

Signal bridge,

 pluggable, for bridging group signaling when there 

is a free slot on the TMCP

 

SOCKET

 

M socket

TMCP SB

0916602

6

324

PHOENIX CONTACT

Plug-in electronic circuit breakers

– Device circuit breakers for protecting 

against voltage dips caused by overloads 
and short circuits

– Integrated active current limitation
– Remote control possible
– Maximum ease of maintenance thanks to 

the two-piece design

– Snap-in function for secure hold and easy 

removal

– Plug coding possible
– Slim  design

Notes:

For further technical data, drawings, and accessories, and a 

complete data sheet, please visit phoenixcontact.net/products.

Device circuit breakers

Single-channel device circuit breakers

Stop point

typ.

1

,

1

x l

1

,

8

x l

Switching

tim

e

[s]

Multiples of I

N

N

N

With reset input and status output

With control input and group request

With reset input and group request

With floating signal co

phoenixcontact-protection-html.html
background image

2

12

14

13

11

1

C

ont

r

o

l

 

U

nit

I<

LINE (+)

SO

C

ont

r

o

l

SC

L

O

A

D

 (+)

G

N

D

 (-)

O

n

/O

ff

2

12

14

13

11

1

C

ont

r

o

l

 

U

nit

I<

LINE (+)

SO

R

eset

SC

L

O

A

D

 (+)

G

N

D

 (-)

O

n

/O

ff

LINE (+)

SO

O

n

/O

ff

S

I

SC

L

O

A

D

 (L+)

G

N

D

 (-)

C

ont

r

o

l

 

U

nit

2

12

14

13

11

1

LINE

L

O

A

D

For further information and full technical data, visit phoenixcontact.net/products

 

Ex: 

 

 

Ex: 

 

 

 

Total width 12.5 mm

Total width 12.5 mm

Total width 12.5 mm

Technical data

Technical data

Technical data

24 V DC

24 V DC

24 V DC

Depends on the product version selected

Depends on the product version selected

Depends on the product version selected

Depends on the product version selected

Switch-off time

See tripping characteristic

See tripping characteristic

See tripping characteristic

See tripping characteristic

Typ. 1.8 x I

N

Typ. 1.8 x I

N

Typ. 1.8 x I

N

active active active 

Temperature range

0 °C ... 50 °C (non-condensing)

0 °C ... 50 °C (non-condensing)

0 °C ... 50 °C (non-condensing)

0 °C ... 50 °C (non-condensing)

IP30 (Actuation area)

IP30 (Actuation area)

IP30 (Actuation area)

Standards/regulations

UL 2367 / UL 508 / CSA 22.2

UL 2367 / UL 508 / CSA 22.2

UL 2367 / UL 508 / CSA 22.2

-

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

ECP-E2-1A

0900139

5

ECP-E3 1A

0912041

5

ECP-E2-2A

0900236

5

ECP-E3 2A

0912042

5

ECP 2

0911034

5

ECP-E2-3A

0900333

5

ECP-E3 3A

0912043

5

ECP 3

0911047

5

ECP-E2-4A

0900430

5

ECP-E3 4A

0912044

5

ECP  4

0912034

5

ECP-E2-6A

0900634

5

ECP-E3 6A

0912046

5

ECP  6

0912033

5

ECP-E2-8A

0900838

5

ECP-E3 8A

0912048

5

ECP 8

0912019

5

ECP-E2-10A

0900100

5

ECP-E3 10A

0912050

5

ECP 10

0912020

5

ECP-E2-12A

0900207

5

ECP-E3 12A

0912052

5

ECP 1-2

0912018

5

ECP 3-6

0916536

5

Accessories

Accessories

Accessories

SPRING-LOCK

0713009

10

SPRING-LOCK

0713009

10

SPRING-LOCK

0713009

10

TMCP SOCKET M

0916589

10

TMCP SOCKET M

0916589

10

TMCP SOCKET M

0916589

10

TMCP CONNECT LR

0916592

3

TMCP CONNECT LR

0916592

3

TMCP CONNECT LR

0916592

3

TMCP SB

0916602

6

TMCP SB

0916602

6

TMCP SB

0916602

6

325

PHOENIX CONTACT

Device circuit breakers

Single-channel device circuit breakers

With reset input and status output

With control input and group request

With reset input and group request

With floating signal contact and electrical 

isolation

phoenixcontact-protection-html.html
background image

0

,

0

1

0

,

1

1

1

0

1

0

2

1

0

3

1

0

4

5

1

0

2

3

I

K

E

C

-E 1 ...

1

3

0

V

Line+

L

O

A

D

+

2

13

14

 

 

 

Ex: 

 

Total width 12.5 mm

Technical data

Electrical data

Operating voltage

24 V DC

Nominal current I

N

Depends on the product version selected

Disconnection

Switch-off time

See tripping characteristic

Fuse type

Electronic

General data

Dimensions W/H/D

12.5 mm / 83 mm / 80 mm

Connection method

Screw connection

Connection data solid/stranded/AWG

0.5 ... 16 mm² / 0.5 ... 16 mm² / 20 - 6

Stranded conductor cross section with ferrule

0.5 ... 10 mm²

Ambient temperature (operation)

0 °C ... 50 °C (non-condensing)

Degree of protection

IP20 (Housing)

Flammability rating according to UL 94

V0

Ordering data

Description

Nominal

current

Type

Order No.

Pcs./Pkt.

Electronic circuit breaker,

 signal contact: 1 N/O contact

0.5 A

EC-E1 0.5A

0903022

6

1 A

EC-E1 1A

0903023

6

2 A

EC-E1 2A

0903024

6

3 A

EC-E1 3A

0903025

6

4 A

EC-E1 4A

0903026

6

6 A

EC-E1 6A

0903028

6

8 A

EC-E1 8A

0903029

6

10 A

EC-E1 10A

0903030

6

12 A

EC-E1 12A

0903031

6

Electronic circuit breaker,

 signal contact: 1 N/C contact

0.5 A

EC-E4 0.5A

0903040

6

1 A

EC-E4 1A

0903032

6

2 A

EC-E4 2A

0903033

6

3 A

EC-E4 3A

0903034

6

4 A

EC-E4 4A

0903035

6

6 A

EC-E4 6A

0903036

6

8 A

EC-E4 8A

0903037

6

10 A

EC-E4 10A

0903038

6

12 A

EC-E4 12A

0903039

6

Accessories

Cont. plug-in bridge,

 500 mm long, isolated, can be cut to length, 

for potential distribution

FBST 500-PLC BU

2966692

20

Nominal current: 32 A

FBST 500-PLC RD

2966786

20

FBST 500 TMC-N GY

0901028

10

Screwdriver

SZS 0.6X3,5

1205053

10

326

PHOENIX CONTACT

Stop point

typ.

1

,

1

x l

1

,

8

x l

Switching

tim

e

[s]

Multiples of I

N

N

N

– Selective protection of all load circuits at 

switched-mode power supply units

– A combination of active electronic 

current limitation in the event of short 
circuit and overload shutdown ensures 
that the circuit breaker can respond to 
overloads faster than the switched-mode 
power supply unit

– The residual current is always limited to 

1.3 - 1.8 times the nominal current

Notes:

For further technical data, drawings, and accessories, and a 

complete data sheet, please visit phoenixcontact.net/products.

EC-E1 and EC-E4 electronic circuit 
breakers

Device circuit breakers

Single-channel device circuit breakers

With signal contact as N/C contact or N/O 

contact

phoenixcontact-protection-html.html
background image

0

,

0

1

0

,

1

1

1

0

1

0

2

1

0

3

1

0

4

5

1

0

2

3

I

K

1

3

0

V

Line+

L

O

A

D

+

2

E

C

-E ...

R

eset 22

S

t

a

tus 23

For further information and full technical data, visit phoenixcontact.net/products

 

 

Ex: 

 

Total width 12.5 mm

Technical data

Electrical data

Operating voltage

24 V DC

Nominal current I

N

Depends on the product version selected

Disconnection

Switch-off time

See tripping characteristic

Fuse type

Electronic

General data

Dimensions W/H/D

12.5 mm / 83 mm / 80 mm

Connection method

Screw connection

Connection data solid/stranded/AWG

0.5 ... 16 mm² / 0.5 ... 16 mm² / 26 - 6

Stranded conductor cross section with ferrule

0.5 ... 10 mm²

Ambient temperature (operation)

0 °C ... 50 °C (non-condensing)

Degree of protection

IP20 (Housing)

Flammability rating according to UL 94

V0

Ordering data

Description

Nominal

current

Type

Order No.

Pcs./Pkt.

Electronic circuit breaker,

 with reset input

0.5 A

EC-E  0.5A DC24V

0903041

6

1 A

EC-E  1A DC24V

0903042

6

2 A

EC-E  2A DC24V

0903043

6

3 A

EC-E  3A DC24V

0903044

6

4 A

EC-E  4A DC24V

0903045

6

6 A

EC-E  6A DC24V

0903046

6

8 A

EC-E  8A DC24V

0903047

6

10 A

EC-E 10A DC24V

0903048

6

12 A

EC-E 12A DC24V

0903049

6

Accessories

Cont. plug-in bridge,

 500 mm long, isolated, can be cut to length, 

for potential distribution

FBST 500-PLC BU

2966692

20

Nominal current: 32 A

FBST 500-PLC RD

2966786

20

FBST 500 TMC-N GY

0901028

10

327

PHOENIX CONTACT

Stop point

typ.

1

,

1

x l

1

,

8

x l

Switching

tim

e

[s]

Multiples of I

N

N

N

– Selective protection of all 24 V DC load 

circuits at switched-mode power supply 
units

– A combination of active electronic 

current limitation in the event of short 
circuit and overload shutdown ensures 
that the circuit breaker can respond to 
overloads faster than the switched-mode 
power supply unit

– The residual current is always limited to 

1.3 - 1.8 times the nominal current

Notes:

For further technical data, drawings, and accessories, and a 

complete data sheet, please visit phoenixcontact.net/products.

EC-E electronic circuit breakers

Device circuit breakers

Single-channel device circuit breakers

With reset input and status output

phoenixcontact-protection-html.html
background image

1

0000

1

000

1

00

1

0

1

0

,

1

0

,

0

1

0

,

00

1

1 2

2

0

4

4

0

6

1

0

1

00

2

2

0

4

4

0

6

1

0

1

00

8

...

16

A

0,5

...

6

A

12,3

90

4

0

,

7

45

77

,3

 

 

 

 

 

 

Total width 12.3 mm

Technical data

Electrical data

IEC

UL / CUL

CSA

Rated  voltage

50 V DC

50 V DC

-

Nominal current I

N

Depends on the product version selected

Disconnection

Switch-off time

See tripping characteristic

Fuse type

SFB

Rated short-circuit switching capacity I

cn

- / 600 A (50 V DC)

Switching cycles, max.

6000 (at 1 x I

n

)

General data

Ambient temperature (operation)

-30 °C ... 60 °C

Degree of protection

IP30 (Actuation area)

Standards/regulations

EN 60934 / UL 1077 / UL 508 / CSA 22.2

Ordering data

Description

Nominal

current

Type

Order No.

Pcs./Pkt.

Thermomagnetic circuit breaker,

 plug-in, 1-pos., signal contact 

1 PDT

0.5 A

CB TM1 0.5A SFB P

2800835

1

1 A

CB TM1 1A SFB P

2800836

1

2 A

CB TM1 2A SFB P

2800837

1

3 A

CB TM1 3A SFB P

2800838

1

4 A

CB TM1 4A SFB P

2800839

1

5 A

CB TM1 5A SFB P

2800840

1

6 A

CB TM1 6A SFB P

2800841

1

8 A

CB TM1 8A SFB P

2800842

1

10 A

CB TM1 10A SFB P

2800843

1

12 A

CB TM1 12A SFB P

2800844

1

16 A

CB TM1 16A SFB P

2800845

1

Thermomagnetic circuit breaker,

 plug-in, 2-pos., signal contact 

1 PDT

0.5 A

CB TM2 0.5A SFB P

2800868

1

1 A

CB TM2 1A SFB P

2800869

1

2 A

CB TM2 2A SFB P

2800870

1

3 A

CB TM2 3A SFB P

2800871

1

4 A

CB TM2 4A SFB P

2800872

1

5 A

CB TM2 5A SFB P

2800873

1

6 A

CB TM2 6A SFB P

2800874

1

8 A

CB TM2 8A SFB P

2800875

1

10 A

CB TM2 10A SFB P

2800876

1

12 A

CB TM2 12A SFB P

2800877

1

16 A

CB TM2 16A SFB P

2800878

1

Accessories

Bridge plug,

 0 volt distribution

CB PT BRIDGE

2801014

1

Base element

With Push-in connection technology

CB 1/6-2/4 PT-BE

2800929

10

With screw connection technology

CB 1/10-1/10 UT-BE

2801305

10

For the PCB

CB S-BE

2905067

30

Switching

time

[s]

Multiples of I

N

328

PHOENIX CONTACT

– Device circuit breakers for protecting 

against voltage dips caused by overloads 
and short circuits

– SFB characteristic curve enables longer 

cables and tripping times of < 10 ms

– Maximum ease of maintenance thanks to 

the two-piece design

– Snap-in function for secure hold and easy 

removal

– Plug coding possible
– Slim  design

Notes:

For additional technical data, drawings, and accessories, please 

visit phoenixcontact.net/products.

Plug-in thermomagnetic circuit 
breakers

Tripping characteristic in the DC range 

Device circuit breakers

Single-channel device circuit breakers

Can be plugged in, SFB characteristic curve

The figure shows the complete module consisting of a base 

element and plug

phoenixcontact-protection-html.html
background image

1

0000

1

000

1

00

1

0

1

0

,

1

0

,

0

1

0

,

00

1

1 2

2

0

4

4

0

6

1

0

1

00

2

2

0

4

4

0

6

1

0

1

00

8

...

16

A

0,5

...

6

A

12,3

90

4

0

,

7

45

77

,3

90

4

0

,

7

45

77

,3

24,6

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

 

 

 

 

 

 

 

 

Total width 12.3 mm

Total width 24.6 mm

Technical data

Technical data

Electrical data

IEC

UL / CUL

CSA

IEC

UL / CUL

CSA

Rated voltage

240 V AC

277 V AC

-

240 V AC

277 V AC

-

Rated voltage

50 V DC

50 V DC

-

80 V DC

80 V DC

-

Nominal current I

N

Depends on the product version selected

Depends on the product version selected

Disconnection

Switch-off time

See tripping characteristic

See tripping characteristic

Fuse type

normal blow

normal blow

Rated short-circuit switching capacity I

cn

300 A (240 V AC) / 600 A (50 V DC)

400 A (240 V AC) / 600 A (80 V DC)

Switching cycles, max.

6000 (at 1 x I

n

)

6000 (240 V AC/1 x I

n

)

General data

Ambient temperature (operation)

-30 °C ... 60 °C

-30 °C ... 60 °C

Degree of protection

IP30 (Actuation area)

IP30 (Actuation area)

Standards/regulations

EN 60934 / UL 1077 / UL 508 / CSA 22.2

EN 60934 / UL 1077 / UL 508 / CSA 22.2

Ordering data

Ordering data

Description

Nominal

current

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Thermomagnetic circuit breaker,

 plug-in, signal contact 1 PDT

0.5 A

CB TM1 0.5A M1 P

2800846

1

CB TM2 0.5A M1 P

2800879

1

1 A

CB TM1 1A M1 P

2800847

1

CB TM2 1A M1 P

2800880

1

2 A

CB TM1 2A M1 P

2800848

1

CB TM2 2A M1 P

2800881

1

3 A

CB TM1 3A M1 P

2800849

1

CB TM2 3A M1 P

2800882

1

4 A

CB TM1 4A M1 P

2800850

1

CB TM2 4A M1 P

2800883

1

5 A

CB TM1 5A M1 P

2800851

1

CB TM2 5A M1 P

2800884

1

6 A

CB TM1 6A M1 P

2800852

1

CB TM2 6A M1 P

2800885

1

8 A

CB TM1 8A M1 P

2800853

1

CB TM2 8A M1 P

2800886

1

10 A

CB TM1 10A M1 P

2800854

1

CB TM2 10A  M1 P

2800887

1

12 A

CB TM1 12A M1 P

2800855

1

CB TM2 12A  M1 P

2800888

1

16 A

CB TM1 16A M1 P

2800856

1

CB TM2 16A  M1 P

2800889

1

Accessories

Accessories

Bridge plug,

 0 volt distribution

CB PT BRIDGE

2801014

1

CB PT BRIDGE

2801014

1

Base element

With Push-in connection technology

CB 1/6-2/4 PT-BE

2800929

10

CB 1/6-2/4 PT-BE

2800929

10

With screw connection technology

CB 1/10-1/10 UT-BE

2801305

10

CB 1/10-1/10 UT-BE

2801305

10

For the PCB

CB S-BE

2905067

30

CB S-BE

2905067

30

Multiples of I

N

Switching

time

[s]

Tripping characteristic

Gray: DC range, blue: AC range

The figure shows the complete module consisting of a base 

element and plug

The figure shows the complete module consisting of a base 

element and plug

329

PHOENIX CONTACT

Device circuit breakers

Single-channel device circuit breakers

Can be plugged in, M1 characteristic curve, 

1-pos.

Can be plugged in, M1 characteristic curve, 

2-pos.

– Device circuit breakers for protecting 

against voltage dips caused by overloads 
and short circuits

– Medium-blow and fast-blow tripping 

characteristics

– 1 and 2-pos. circuit breakers
– Maximum ease of maintenance thanks to 

the two-piece design

– Snap-in function for secure hold and easy 

removal

– Plug coding possible
– Slim  design

Plug-in thermomagnetic circuit 
breakers

phoenixcontact-protection-html.html
background image

1

0000

1

000

1

00

1

0

1

0

,

1

0

,

0

1

0

,

00

1

1 2

2

0

4

4

0

6

1

0

1

00

2

2

0

4

4

0

6

1

0

1

00

8

...

16

A

0,5

...

6

A

12,3

90

4

0

,

7

45

77

,3

90

4

0

,

7

45

77

,3

24,6

 

 

 

 

 

 

 

 

 

 

 

Technical data

Technical data

Electrical data

IEC

UL / CUL

CSA

IEC

UL / CUL

CSA

Rated voltage

50 V DC

50 V DC

-

80 V DC

80 V DC

-

Nominal current I

N

Depends on the product version selected

Depends on the product version selected

Disconnection

Switch-off time

See tripping characteristic

See tripping characteristic

Fuse type

fast blow

fast blow

Rated short-circuit switching capacity I

cn

- / 600 A (50 V DC)

- / 600 A (80 V DC)

Switching cycles, max.

6000 (at 1 x I

n

)

6000 (240 V AC/1 x I

n

)

General data

Ambient temperature (operation)

-30 °C ... 60 °C

-30 °C ... 60 °C

Degree of protection

IP30 (Actuation area)

IP30 (Actuation area)

Standards/regulations

EN 60934 / UL 1077 / UL 508 / CSA 22.2

EN 60934 / UL 1077 / UL 508 / CSA 22.2

Ordering data

Ordering data

Description

Nominal

current

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Thermomagnetic circuit breaker,

 plug-in, signal contact 1 PDT

0.5 A

CB TM1 0.5A F1 P

2800857

1

CB TM2 0.5A F1 P

2800890

1

1 A

CB TM1 1A F1 P

2800858

1

CB TM2 1A F1 P

2800891

1

2 A

CB TM1 2A F1 P

2800859

1

CB TM2 2A F1 P

2800892

1

3 A

CB TM1 3A F1 P

2800860

1

CB TM2 3A F1 P

2800893

1

4 A

CB TM1 4A F1 P

2800861

1

CB TM2 4A F1 P

2800894

1

5 A

CB TM1 5A F1 P

2800862

1

CB TM2 5A F1 P

2800895

1

6 A

CB TM1 6A F1 P

2800863

1

CB TM2 6A F1 P

2800896

1

8 A

CB TM1 8A F1 P

2800864

1

CB TM2 8A F1 P

2800897

1

10 A

CB TM1 10A F1 P

2800865

1

CB TM2 10A F1 P

2800898

1

12 A

CB TM1 12A F1 P

2800866

1

CB TM2 12A F1 P

2800899

1

16 A

CB TM1 16A F1 P

2800867

1

CB TM2 16A F1 P

2800900

1

Accessories

Accessories

Bridge plug,

 0 volt distribution

CB PT BRIDGE

2801014

1

CB PT BRIDGE

2801014

1

Base element

With Push-in connection technology

CB 1/6-2/4 PT-BE

2800929

10

CB 1/6-2/4 PT-BE

2800929

10

With screw connection technology

CB 1/10-1/10 UT-BE

2801305

10

CB 1/10-1/10 UT-BE

2801305

10

For the PCB

CB S-BE

2905067

30

CB S-BE

2905067

30

Switching

time

[s]

Multiples of I

N

Tripping characteristic in the DC range 

The figure shows the complete module consisting of a base 

element and plug

The figure shows the complete module consisting of a base 

element and plug

330

PHOENIX CONTACT

Device circuit breakers

Single-channel device circuit breakers

Can be plugged in, F1 characteristic curve, 

1-pos.

Can be plugged in, F1 characteristic curve, 

2-pos.

– Device circuit breakers for protecting 

against voltage dips caused by overloads 
and short circuits

– Medium-blow and fast-blow tripping 

characteristics

– 1 and 2-pos. circuit breakers
– Maximum ease of maintenance thanks to 

the two-piece design

– Snap-in function for secure hold and easy 

removal

– Plug coding possible
– Slim  design

Plug-in thermomagnetic circuit 
breakers

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Technical data

Technical data

Electrical data

... PT-BE

... UT-BE

Rated surge voltage

4 kV

2.5 kV

-

General data

Dimensions W/H/D

12.3 mm / 90 mm / 46.7 mm

12.3 mm / 90.8 mm / 70 mm

12.3 mm / 34.8 mm / 36.4 mm

Connection method

Push-in connection

Screw connection

Solder connection

Ambient temperature (operation)

-30 °C ... 60 °C

-30 °C ... 60 °C

-30 °C ... 60 °C

Degree of protection

IP30 (Actuation area)

IP30 (Actuation area)

IP30 (Plug-in area with plugged-in device) / IP00 (Connection area)

Flammability rating according to UL 94

V0

V0

V-0

Standards/regulations

IEC

 

60947-7-1

UL 1059

DIN

 

EN 50155 / IEC 60068-2

Ordering data

Ordering data

Description

Type

Order No.

Pcs./Pkt.

Type

Order No.

Pcs./Pkt.

Base element

For the PCB

CB 1/6-2/4 PT-BE

2800929

10

CB S-BE

2905067

30

CB 1/10-1/10 UT-BE

2801305

10

Accessories

Accessories

Plug-in bridge,

 red

Number of positions

2

FBS  2-6

3030336

50

3

FBS  3-6

3030242

50

4

FBS  4-6

3030255

50

5

FBS  5-6

3030349

50

10

FBS 10-6

3030271

10

20

FBS 20-6

3030365

10

50

FBS 50-6

3032224

10

Plug-in bridge, 

blue

Number of positions

2

FBS  2-6 BU

3036932

50

3

FBS  3-6 BU

3036945

50

4

FBS  4-6 BU

3036958

50

5

FBS  5-6 BU

3036961

50

10

FBS 10-6 BU

3032198

10

20

FBS 20-6 BU

3032208

10

50

FBS 50-6 BU

3032211

10

Plug-in bridge,

 gray

Number of positions

2

FBS  2-6 GY

3032237

50

3

FBS  3-6 GY

3032240

50

4

FBS  4-6 GY

3032279

50

5

FBS  5-6 GY

3032266

50

10

FBS 10-6 GY

3032253

10

331

PHOENIX CONTACT

Device circuit breakers

Single-channel device circuit breakers

1-pos, with screw or Push-in connection 

technology

For the PCB

Base elements

– For accommodating CB TM.../CB E.... 

device circuit breakers

– DIN rail module
– With bridge shafts
– Systematic structure with 1-channel base 

elements possible

Notes:

Can be loaded with up to 41

 

A if two bridges are connected for the 

supply.

Base element and plug-in bridges

phoenixcontact-protection-html.html
background image

1

2

2

0

4

5

0

6

8

12

7

A

<

7

A

1

0000

1

000

1

00

1

0

1

0

,

1

0

,

0

1

0

,

00

1

1

2

2

0

4

5

0

6

8

12

 

 

 

 

Total width 12.3 mm

Technical data

Electrical data

IEC

UL / CUL

CSA

Rated voltage

240 V AC

240 V AC

-

Rated  voltage

28 V DC

28 V DC

-

Nominal current I

N

Depends on the product version selected

Disconnection

Switch-off time

See tripping characteristic

Fuse type

Normal blow (M1)

Rated short-circuit switching capacity I

cn

200 A (240 V AC) / 400 A (28 V DC)

Switching cycles, max.

6000 (at 1 x I

n

)

General data

Dimensions W/H/D

12.3 mm / 85.5 mm / 89.5 mm

Connection method

Screw connection

Connection data solid/stranded/AWG

0.2 ... 10 mm² / 0.2 ... 10 mm² / 24 - 8

Stranded conductor cross section with ferrule

0.25 ... 6 mm²

Ambient temperature (operation)

-30 °C ... 60 °C

Degree of protection

IP40 (Actuation area) / IP20 (Connection area)

Standards/regulations

EN 60934 / UL 1077 / CSA 22.2 / EAC

Ordering data

Description

Nominal

current

Type

Order No.

Pcs./Pkt.

Thermomagnetic circuit breaker, 

for mounting on NS

 

35...

0.5 A

UT 6-TMC M 0.5A

0916603

6

1 A

UT 6-TMC M 1A

0916604

6

2 A

UT 6-TMC M 2A

0916605

6

4 A

UT 6-TMC M 4A

0916606

6

5 A

UT 6-TMC M 5A

0916607

6

6 A

UT 6-TMC M 6A

0916608

6

8 A

UT 6-TMC M 8A

0916609

6

10 A

UT 6-TMC M 10A

0916610

6

12 A

UT 6-TMC M 12A

0916611

6

15 A

UT 6-TMC M 15A

0916612

6

16 A

UT 6-TMC M 16A

0916613

6

Accessories

Plug-in bridge,

 red

Number of positions

2

FBS  2-6

3030336

50

3

FBS  3-6

3030242

50

4

FBS  4-6

3030255

50

5

FBS  5-6

3030349

50

10

FBS 10-6

3030271

10

20

FBS 20-6

3030365

10

Multiples of I

N

Switching

time

[s]

332

PHOENIX CONTACT

– Thermomagnetic circuit breakers feature 

a compact design, large-surface marking 
options, and a double plug-in bridge shaft

– With bridge shafts enabling them to be 

bridged together easily

– 12.3 mm compact design
– High level of system availability thanks to 

their reclosure function and clear status 
display

– Eleven nominal current levels can be 

selected from 0.5 A to 16 A

– Clear assignment of the relevant circuit 

breaker thanks to the large center 
marking area

Thermomagnetic circuit breaker 
UT 6-TMC ...

Tripping characteristic

Device circuit breakers

Single-channel device circuit breakers

DIN-rail-mountable

Notes:

For further technical data, drawings, and accessories, and a 

complete data sheet, please visit phoenixcontact.net/products.

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

Total width 12.5 mm

Technical data

Electrical data

IEC

UL / CUL

CSA

Rated voltage

250 V AC

-

-

Rated voltage

65 V DC

-

-

Nominal current I

N

Depends on the product version selected

Disconnection

Switch-off time

See tripping characteristic

Fuse type

Fast blow (F1)

Rated short-circuit switching capacity I

cn

400 A / 2500 A (32 V DC)

General data

Dimensions W/H/D

12.5 mm / 82.5 mm / 96 mm

Connection method

Screw connection

Connection data solid/stranded/AWG

0.2 ... 6 mm²

1

) / 0.2 ... 4 mm² / 24 - 10

Stranded conductor cross section with ferrule

0.25 ... 4 mm²

Ambient temperature (operation)

-30 °C ... 60 °C

Degree of protection

IP30 (Actuation area) / IP20 (Connection area)

Ordering data

Description

Nominal

current

Type

Order No.

Pcs./Pkt.

Thermomagnetic circuit breaker,

 with universal foot for 

mounting on NS

 

32... or NS

 

35...

TMC 1 F1 100  0.2A

0914015

6

333

PHOENIX CONTACT

Device circuit breakers

Single-channel device circuit breakers

DIN-rail-mountable

– Available with fast-blow and medium-

blow characteristic curve for various 
nominal current strengths

– Single or two-pos. main current path

Notes:

1

) Main contact

For further technical data, drawings, and accessories, and a 

complete data sheet, please visit phoenixcontact.net/products.

TMC thermomagnetic circuit breaker

TMC type key 

The type key indicates the unique 

structure of the product.

Type

Main current paths

Characteristic curve

Auxiliary contact versions

Nominal current

TMC

1

=

 Single-pos.

2

=

 Two-pos.

3

=

 Three-pos.

F1

=

 Therm. 1.05 - 1.4 I

N

,

magn. 2 - 4 I

N

 DC (fast-blow),

Only for DC applications

M1

=

 Therm. 1.05 - 1.4 I

N

,

magn. 6 - 12 I

N

 AC,

7.8 - 15.6 I

N

 DC

(medium-blow)

100

=

 Single-pos.: 1 N/O contact

200

=

 Single-pos.: 1 N/C contact

120

=

 Two-pos.: 1 N/O contact, 

1 N/C contact

122

=

 Three-pos.: 1 N/O contact, 

  2 N/C contacts

0.2 A

 2.5 A

0.3 A

3 A

0.4 A

4 A

0.5 A

5 A

0.6 A

6 A

0.8 A

8 A

1 A

     

10 A

1.5 A

 

12 A

2 A

 

16 A

TMC with single-pos. main current path, one N/O contact, medium-blow characteristic curve, and a nominal current of 2 A.

TMC

1

M1

100

2 A

Ordering example:

phoenixcontact-protection-html.html
background image

0

,

1

0

,

1

1

1

1

0

1

0

1

0

2

1

0

2

1

0

3

1

0

3

1

0

4

1

0

4

0

,

4

1 2

1

0

2

0

4

4

0

,

4

1 2

1

0

2

0

-

4

0

°

C

-

4

0

°

C

-

4

0

°

C

+

23

°

C

+

23

°

C

+

8

5

°

C

+

8

5

°

C

T

C

P

/DC32

V

7

,

5

A -

30

A

TCP/DC32

V

7

,

5

A -

30

A

TCP/DC32

V

5

A

Total width 6 mm

Technical data

Electrical data

IEC

UL / CUL

CSA

Rated voltage

32 V DC

-

-

Nominal current I

N

Depends on the product version selected

Disconnection

Switch-off time

See tripping characteristic

Fuse type

Slow-blow

Rated short-circuit switching capacity I

cn

 50 A (300 switch-offs)

General data

Dimensions W/H/D

6 mm / 20.3 mm / 24 mm

Height

17 mm

Ambient temperature (operation)

-40 °C ... 85 °C

Degree of protection

IP30 (Actuation area)

Ordering data

Description

Nominal

current

Type

Order No.

Pcs./Pkt.

One-pos., thermal circuit breaker

, for fuse holders in acc. with 

ISO 8820-3

5 A

TCP  5/DC32V

0700005

50

7.5 A

TCP  7,5/DC32V

0700007

50

10 A

TCP 10/DC32V

0700010

50

15 A

TCP 15/DC32V

0700015

50

20 A

TCP 20/DC32V

0700020

50

25 A

TCP 25/DC32V

0700025

50

30 A

TCP 30/DC32V

0700030

50

40 A

TCP 40/DC32V

0700040

50

Accessories

Fuse terminal block

, with spring-cage connection, for mounting 

on NS

 

35...

ST 4-FSI/C

3036372

50

with LED display for 12

 

V

 

DC, 1.7

 

mA

1

)

ST 4-FSI/C-LED 12

3036495

50

with LED display for 24 V DC, 1.9

 

mA

1

)

ST 4-FSI/C-LED 24

3036505

50

Fuse terminal block

, with screw connection, for mounting on 

NS

 

32... or NS

 

35...

UK  6-FSI/C

3118203

50

with LED display for 12

 

V

 

DC, 1.7

 

mA

1

)

UK  6-FSI/C-LED12

3001925

50

with LED display for 24 V DC, 1.9

 

mA

1

)

UK  6-FSI/C-LED24

3001938

50

Fuse terminal block

, with Push-in connection, for mounting on 

NS

 

35...

PT 6-FSI/C

3212166

50

with LED display for 6 - 12

 

V

 

DC, 0.31 - 0.95

 

mA

PT 6-FSI/C-LED 12

3212169

50

with LED display for 12 - 30

 

V

 

DC, 0.31 - 0.95

 

mA

PT 6-FSI/C-LED 24

3212172

50

with LED display for 24 - 48

 

V

 

DC, 0.31 - 0.95

 

mA

PT 6-FSI/C-LED 48

3212175

50

Switching

tim

e[

s]

Multiples of I

N

334

PHOENIX CONTACT

– The pluggable thermal miniature circuit-

breaker combines the protective 
mechanism of an automotive flat-type 
fuse with the advantages of a circuit-
breaker

– In the event of an error, the time-sensitive 

search for a suitable replacement fuse is 
eliminated thanks to the reclosure 
function

– The area of application extends to the 

protection of integrated circuits in all 
battery and onboard systems with up to 
32 V DC

– Fits in all fuse holders designed for flat-

type fuse-links according to ISO 8820-3 
(DIN 72581-3)

– A version with screw or spring-cage 

connection is used as a basic terminal 
block

TCP thermal circuit breaker

Tripping characteristic

Device circuit breakers

Single-channel device circuit breakers

For fuse holder

Notes:

1

) If the fuse is faulty, the downstream circuit is not off load.

Attention: The reset button must not be obstructed. During 

installation, please leave enough room for using button.

For further technical data, drawings, and accessories, and a 

complete data sheet, please visit phoenixcontact.net/products.

You can find a wide selection of fuse terminal blocks in Catalog

 

1

phoenixcontact-protection-html.html
background image

2

4

6

8

1

0

2

0

3

0

1

0

,

8

1

0

3

1

0

4

1

0

2

1

0

1

0

,1

0

,25 - 4 A

6 - 1

0

A

For further information and full technical data, visit phoenixcontact.net/products

 

 

 

Total width 8.2 mm

Technical data

Electrical data

IEC

UL / CUL

CSA

Rated voltage

250 V AC

-

-

Rated voltage

65 V DC

-

-

Nominal current I

N

Depends on the product version selected

Disconnection

Switch-off time

See tripping characteristic

Fuse type

Slow-blow

Rated short-circuit switching capacity I

cn

-

General data

Dimensions W/H/D

8.2 mm / 64 mm / 88.5 mm

Ambient temperature (operation)

-20 °C ... 60 °C

Degree of protection

IP40 (Actuation area)

Ordering data

Description

Nominal

current

Type

Order No.

Pcs./Pkt.

Thermal miniature circuit breaker, 

can be plugged into UK 6 

FSI/C or ST 4-FSI/C fuse terminal block 

0.1 A

TCP  0.1A

0712107

20

0.25 A

TCP  0.25A

0712123

20

0.5 A

TCP  0.5A

0712152

20

1 A

TCP  1A

0712194

20

2 A

TCP  2A

0712217

20

3 A

TCP  3A

0712233

20

4 A

TCP  4A

0712259

20

6 A

TCP  6A

0712275

20

8 A

TCP  8A

0712291

20

10 A

TCP 10A

0712314

20

Accessories

Fuse terminal block

, for mounting on NS

 

32... or NS

 

35...

UK  6-FSI/C

3118203

50

Fuse terminal block,

 for flat-type fuses

ST 4-FSI/C

3036372

50

Lateral groove marking

For ZB 5, see page 197

Response

[s]

Multiples of I

N

335

PHOENIX CONTACT

– The reclosable thermal circuit breaker is 

available in nine nominal current levels 
ranging from 0.25 to 10 A

– The integrated switching function enables 

immediate reclosure and thus ensures the 
availability of the system

– Compact  design
– A version with screw or spring-cage 

connection is used as a basic terminal 
block

– Potential distribution possible by means 

of bridges

TCP thermal circuit breaker

Tripping characteristic

Device circuit breakers

Single-channel device circuit breakers

Can be plugged into a fuse terminal block

Notes:

When mounted in rows, the nominal device current can be limited 

to just

 

80% or must be overdimensioned accordingly.

For further technical data, drawings, and accessories, and a 

complete data sheet, please visit phoenixcontact.net/products.

phoenixcontact-protection-html.html
background image

IN

OUT

IN

OUT

1

2

3

4

1

2

3

4

336

PHOENIX CONTACT

Installation notes for 
surge protective devices

Cable routing:

Protected and unprotected cables 

must not be laid directly parallel to one 
another. They must be physically separated 
or shielded from one another so that 
surge voltages cannot be coupled from 
unprotected cables to protected ones. If 
crossed, cables that can influence one 
another must be crossed at right angles.

Quenching follow currents:

Gas-filled surge arresters only have 

limited self-quenching capability and are 
therefore almost always suitable for 
protecting message transmission systems. 

The arresters easily meet the 

requirements of the usually high-
impedance remote indication circuits. 
Distinct quenching behavior is observed 
under the following conditions in the case 
of systems with higher operating voltage 
or lower impedance:

AC application:

 if the possible 

short-circuit current of the source 
exceeds the alternating current carrying 
capacity, a fuse is required to prevent 
overheating caused by the follow current.  

DC application:

 for voltages 

> 12 V DC, the possible short-circuit 
current of the source must not exceed 
100 mA. Otherwise a fuse that enables 
shutdown within 5 seconds should be 
selected. Self-quenching capability is 
ensured for voltages 

 12 V. Please note, 

however, that the specific technical data 
for the product must always be observed.

Backup fuse:

 the system must be 

protected against impermissibly high 
short-circuit currents due to arrester 
overload. The maximum permissible or 
required backup fuse for the affected 
arrester is documented in the technical 
data of the relevant product.

Installation direction:

Surge protective devices with a 

multi-stage configuration which are 
looped into the circuit are marked “

IN

” or 

“unprotected” and “

OUT

” or 

“protected”. They must be connected 
before the device to be protected so that 

IN

” / “unprotected” points towards the 

direction from which the surge voltage is 
expected.

  The device to be protected should be 

connected to the terminal points marked 

OUT

” / “protected”. This is the only way 

to ensure correct operation of the surge 
protective device in the event of a surge 
voltage coupling.

Connection:

The protective conductor connection 

of the system to be protected should be 
connected directly and via the shortest 
route to the ground connection of the 
surge protective device or the 
corresponding connection terminal block 
on the “

OUT

” / “protected” side of the 

surge protective device. 

This is the only way to ensure that 

impermissibly high voltages due to 
potential increases caused by discharge 
currents are prevented between the 
ground connections of the surge 
protective device and the device to be 
protected. The same is true for the 
connection between ground and the live 
conductors of the device to be protected 
(see figure: ground connection).

Equipotential bonding:

Correct operation of the surge 

protective devices requires complete 
equipotential bonding in accordance with 
the applicable regulations.

Ground connection

Electronics

Electronics

Correct

Incorrect

Surge voltage limiting 
components

The main function-specific 

components for lightning current arresters 
and surge protective devices are spark 
gaps, gas-filled surge arresters, varistors, 
and diodes, as well as decoupling 
impedances. 

All components have specific 

advantages and disadvantages. In order to 
achieve optimum protection, protective 
circuits and multi-stage protection 
concepts that combine various 
components can be implemented.

Suppressor diode

The reverse voltage U

R

 is the highest 

voltage that the diode can safely block. 
A current of 1 mA flows through the 
suppressor diode at the breakdown 
voltage U

B

. At this point the suppressor 

diode starts limiting the surge voltage.

The maximum clamping voltage U

C

 is 

the highest voltage which can be present 
at the suppressor diode in the event of a 
peak pulse current I

pp

 (10/1000) μs.

U/I characteristic curve of a suppressor diode

Explanation:

U

R

= Reverse voltage

U

B

= Breakdown voltage

U

C

= Clamping voltage

I

pp

= Peak pulse current

I

R

= Reverse current

Technical information

General installation notes/surge voltage limiting components

phoenixcontact-protection-html.html
background image

10

-5

10

-3

10

0

10

3

A

10

5

I

U

N

U

V

A

B

12

00

V

V

/

U

S

Z

800

6

00

4

00

2

00

0

1

0

2

1

0

4

1

0

6

1

0

8

V

/

s 1

0

1

0

du

/

dt

dv

/

dt

1

00

V

/

s

1

00

V

/

s

m

1 kV

/

s

m

1

0

kV

/

s

m

337

PHOENIX CONTACT

Varistors

Block varistor with thermal disconnect device

U/I characteristic curve of metal oxide varistors

Explanation:

= High-resistance operating area

= Low-resistance operating area/

limiting area

Disc varistor

Varistors are “voltage-dependent 

resistors” which, due to their voltage/
current characteristic curves enable a high 
discharge capacity with a low residual 
voltage.

Gas-filled surge arresters consist of an 

electrode arrangement in a ceramic or 
glass tube. Between the electrodes is an 
inert gas, such as argon or neon. When 
the igniting voltage is reached, the 
component changes to a low-resistance 
state as a result of the gas discharge used. 
The igniting voltage is not a constant, 
instead it is dependent on the rate of rise 
of the surge voltage.

After igniting the discharge path, an arc 

voltage between 10 and 30 V typically 
occurs, which can be measured as a 
voltage drop at the arrester. In this 
low-resistance state, a line follow current, 
whose value depends on the impedance of 
the mains connected upstream, can flow 
through the arrester. In order to interrupt 
line follow currents that exceed the 
self-quenching capability, a fuse must be 
connected upstream of the surge arrester. 
Series connection of varistors or resistors 
is also possible.

Characteristic ignition curve of a gas-filled surge arrester

Static response behavior

Dynamic response behavior

Gas-filled surge arresters

Spark gaps

ArC spark gap

The ArC spark gap in the FLASHTRAB 

lightning current arrester is based on arc 
chopping technology. Two spark horns 
positioned opposite one another are kept 
at a distance by an isolator bridge bar. In 
addition, a baffle plate is fitted below the 
electrodes in the direction of the opening. 
In the event of a surge voltage, surface 
discharge occurs along the isolator bridge 
bar, which creates an arc. This is driven 
along the spark horns towards the baffle 
plate where it is chopped up. The resulting 
physical effects quench the arc and the 
associated line follow currents. 
A significant increase in the follow current 
quenching capacity can be achieved with 
spark gap types in which quenching plates 
are arranged around the spark horns. 

Characteristic ignition curve of a spark gap

Encapsulated ArC spark gap

ArC spark gap with quenching plates

Technical information

General installation notes/surge voltage limiting components

phoenixcontact-protection-html.html
background image

Explanation of terms

Surge protective devices

AC withstand voltage

The r.m.s. value of the highest 

sinusoidal voltage at mains frequency 
which will not lead to a disruptive 
discharge under the specified test 
conditions.

Aging

Modification of the original 

performance data due to disturbing 
pulses, operation or unfavorable ambient 
conditions.

Ambient conditions

The immediate ambient conditions 

for the device or the relevant air and 
creepage distances.

Arc voltage U

bo

The arc voltage is the instantaneous 

value of the voltage on a discharge path 
(arc discharge) during an arresting 
process. 

Arrester

Item of equipment that mainly 

consists of voltage-dependent resistors 
and/or spark gaps. Both elements can be 
connected in series or in parallel, or even 
used individually. Arresters are used to 
protect other electrical equipment and 
electrical systems against impermissibly 
high surge voltages.

Associated electrical equipment

An item of electrical equipment in 

which not all circuits are intrinsically safe, 
but which contains circuits that can 
influence the safety of the intrinsically 
safe circuits to which they are connected.

Asymmetrical interference

Asymmetrical means that the source 

of interference and the potentially 
susceptible equipment are grounded, i.e., 
they have a capacitive or galvanic 
connection to the protective conductor. 
As shown in the figure, the interference 
moves from the source along both 
conductors to the potentially susceptible 
equipment and back via ground. The 
terms “common-mode interference” or 
“common mode” are also used.

Source of 

interference

Potentially 

susceptible 

equipment

The wide range of different 

applications also requires numerous 
different surge protective devices with 
application-specific properties. Important 
criteria include the type of circuit, the 
surge-voltage limiting properties, and the 
design. The TRABTECH range from 
Phoenix Contact offers numerous 
versions, such as adapters, junction boxes 
or DIN-rail-mountable arresters in a 
modular and compact design, providing 
practical system solutions for all 
applications.

In line with their intended application, 

surge protective devices are designed for 
high electrical loads. However, excessive 
or very frequent surge voltages may lead 
to overload. This can result in a reduction 
or even failure of the protective function, 
and the affected protective device having 
to be replaced. Where possible, surge 
protective devices should therefore have a 
pluggable design and support testing.

The TRABTECH product range from 

Phoenix Contact takes these 
requirements into consideration as far as 
modern technology permits. The product 
range includes surge protective devices in 
the form of adapters, as well as devices 
with a two-piece pluggable modular 
design.

The protective devices in the 

FLASHTRAB, VALVETRAB, PLUGTRAB, 
and COMTRAB product ranges are 
particularly interesting with regard to their 
plug-in capability and testability. They have 
been developed with various protective 
circuits and different nominal voltages for 
applications in power supply, 
measurement and control, and data 
interface protection.

With components that are perfectly 

designed to work together, i.e., gas-filled 
surge arresters, varistors, and suppressor 
diodes depending on the protective 
circuit, their specific advantages are fully 
utilized.

Asymmetrical voltage, common 
mode voltage

Average voltage between each 

conductor and a specified reference 
point, usually reference ground or 
ground.

Burst

Pulses which occur repeatedly within 

a specific time interval.

Common mode voltage

The common mode voltage is the 

voltage which occurs in the event of 
interference between live conductors and 
ground.

Coupling

Interaction between circuits, in which 

energy is transferred capacitively, 
inductively or galvanically from one 
circuit to the other. 

Direct or close-up strikes

These cause surge voltages with an 

energy level that constitutes a 
considerable part of the total energy of 
the lightning discharge.

Discharge of static electricity; 
electrostatic discharge; ESD

The transmission of an electrical 

charge between bodies with different 
electrostatic potentials when they are in 
close proximity or touching.

Disconnect device

This is a device which disconnects a 

SPD from the mains when it fails. It is 
designed to prevent a permanent fault in 
the system caused by the faulty surge 
protective device and provide an optical 
indication of the faulty SPD.

Disturbance variable

The disturbance variable is an 

electromagnetic (or electrical or 
magnetic) variable, which can have an 
undesirable influence on electrical 
equipment.

Electromagnetic compatibility 
(EMC)

The ability of a device or system to 

operate without faults in an 
electromagnetic environment without 
itself causing electromagnetic 
interference, which would be 
unacceptable for other devices in this 
environment. 

Electromagnetic environment

The sum of all electromagnetic 

phenomena at a given location. 

338

PHOENIX CONTACT

Technical information

Explanation of terms

phoenixcontact-protection-html.html
background image

Electromagnetic interference

A loss in the quality of the operating 

behavior, such as malfunction or failure of 
electrical or electronic equipment, that is 
caused by an electromagnetic disturbance 
variable.

Equipment to be protected

All equipment of a structural system 

or a range which requires surge 
protection or lightning protection.

Equipotential bonding

The removal of potential differences 

between conductive parts, in which all 
points assume virtually the same 
potential.

A distinction is made between 

functional equipotential bonding and 
protective equipotential bonding.

Equipotential bonding conductors

These are electrically conductive 

connections used to create equipotential 
bonding.

Equipotential bonding strip

This is the strip which is designed to 

connect protective conductors, 
equipotential bonding conductors, and 
conductors for functional earth 
grounding to the ground conductor and 
the ground electrodes.

Equipotential bonding system

This refers to all the interconnected 

equipotential bonding conductors, 
including the conductive parts such as 
housing or external conductive parts 
which work in the same way.

The equipotential bonding system can 

also be the grounding system or part of a 
grounding system.

Exposure

Exposure is an insufficient distance 

between the lightning protection system 
and metal installations or electrical 
systems which leads to a risk of flashover 
or disruptive discharge in the event of a 
lightning strike.

Exposure voltage

The exposure voltage is a voltage that 

occurs at the exposure point when 
lightning strikes the lightning protection 
system.

Follow current I

f

Current which flows through the SPD 

following discharge and is supplied by the 
mains. The follow current differs 
considerably from the continuous 
operating current.

Gas-filled surge arrester

The gas-filled surge arrester is a 

discharge path which is filled with a gas 
other than air, generally an inert gas.

Ground

This expression refers to the earth 

and the ground.

Ground conductor

A conductor which connects the 

equipment to be grounded to a ground 
electrode, as long as the ground 
conductor is not laid in the ground or, if 
laid in the ground, is insulated.

Ground electrode

A conductor embedded in the ground 

with an electrically conductive 
connection to ground. Parts of supply 
lines to a ground electrode, which are not 
insulated in the ground, are considered to 
be parts of the ground electrode.

Grounding

Grounding is the sum of all means and 

measures used for grounding.

Grounding resistance

The resistance between the 

grounding system and the reference 
ground. The amount of grounding 
resistance depends on the interaction of 
the individual ground electrodes.

Impulse sparkover voltage of 
1.2/50

s

Highest voltage value before the 

disruptive discharge between the 
electrodes of the spark gap of a SPD.

Impulse withstand voltage U

st

The peak value of the highest surge 

voltage with a predefined form and 
polarity, which will not lead to a 
disruptive discharge under the specified 
test conditions.

Note: the impulse withstand voltage 

is equal to or greater than the rated surge 
voltage.

Inactive parts

Inactive parts are conductive parts 

that are electrically isolated from all live 
parts through basic insulation.

Insertion attenuation

To determine the insertion 

attenuation of a SPD, the mains and 
frequency are specified. The attenuation 
value is defined as the ratio of voltages 
that occur immediately before and after 
the insertion point of the SPD to be 
tested. The result is expressed in 
decibels.

Insulation coordination

The assignment of characteristic 

insulation data for an item of equipment 
for:
– Expected surge voltages
– Characteristic data of the surge 

protective device

– Expected ambient conditions
– Protective measures against 

contamination

Interference suppression

Measure to reduce or avoid the 

electromagnetic disturbance variables 
that occur.

Intrinsically safe circuit

A circuit protected against sparks and 

thermal effects that may occur under the 
conditions specified in DIN EN 60079-11 
(which include error-free operation and 
specific fault conditions), which can cause 
the ignition of a particular explosive gas 
atmosphere.

Intrinsically safe electrical 
equipment

Electrical equipment in which all 

circuits are intrinsically safe.

Lightning protection system

All devices as a whole that provide 

external and internal lightning protection 
for the system to be protected.

Lightning surge current I

imp

Lightning surge currents are 

characterized by the parameters peak 
value, charge, specific energy, and current 
rate of rise. The lightning surge current 
I

imp

 is a measurement for the discharge 

capacity of lightning current arresters 
(class I). It is determined according to a 
defined test procedure using 10/350 μs 
waveform test pulses.

Lightning surge voltage

Surge voltage as a result of lightning 

discharge.

339

PHOENIX CONTACT

Technical information

Explanation of terms

phoenixcontact-protection-html.html
background image

Normal mode voltage

The normal mode voltage is the 

voltage which occurs in the event of 
interference between two conductors of 
a circuit.

Potentially susceptible equipment

All electrical equipment whose 

function can be influenced by disturbance 
variables is referred to as potentially 
susceptible equipment. Influence on 
function may be in the form of a 
functional disturbance, reduction in 
function, malfunction or failure.

Protection level U

p

A parameter that characterizes the 

performance capabilities of the SPD with 
regard to voltage limitation via its 
connection terminal blocks. This value, 
which should be specified by the 
manufacturer, must be greater than the 
highest measured value of the clamping 
voltages.  

Protective paths

The voltage-limiting or switching 

components of the SPD can be 
connected between conductor/
conductor, conductor/ground, 
conductor/neutral conductor, and neutral 
conductor/ground or a combination of 
these options. These circuit types are 
referred to as protective paths.

Pulse

Rapid, brief alteration of a physical 

variable, followed by a fast return to the 
original value.

Pulse burst; burst

Result of a limited number of pulses 

or waves of a limited duration.

Rate of rise

Average rate of change of a variable 

between two specified values, e.g., 10% 
and 90% of the peak value.

Reference ground

An area of the earth, particularly of 

the earth's surface, which is so far away 
from the ground conductors that no 
noticeable voltages occur between any 
points of this area as a result of the 
current entering the earth.

Remote strikes

These usually cause surge voltages 

with a significantly lower energy level 
than close-up strikes. Remote strikes are 
responsible for causing surge voltages in 
electrical and electronic systems. 

Lightning test current

The (10/350) 

s lightning test current 

has a rise time of 10 

s and a decay time 

to half-value of 350 

s.

10/350 lightning current pulse according to IEC 62305-1

Live parts

Live parts are conductors and 

conductive parts of equipment that are 
energized under normal operating 
conditions.

Maximum continuous voltage U

C

The rated voltage is the maximum 

permissible r.m.s. value of the 
power-frequency AC voltage, which may 
be permanently applied to the protective 
paths of the arrester.

Nominal current I

N

 or load current I

L

Highest continuous current for 

products according to IEC 61643 which 
can flow through the surge protective 
device at the specified temperature 
without altering the electrical operating 
properties. For higher operating 
temperatures, the nominal current is 
lower (derating).

Nominal discharge surge current I

n

Peak value of the current flowing 

through the SPD with surge form 
(8/20) 

s. It is used to classify the SPD 

according to class II.  Source: 
EN 61643-11

8/20 surge current pulse according to IEC 60060-1

Nominal voltage U

N

A suitable rounded voltage value, 

which is specified by the manufacturer for 
equipment for the purpose of designation 
or identification.

30

60

0

10

100

350

I

( % )

t ( us)

100

90

50

10

0

8

20

I

( % )

t ( us)

Residual current device (RCD)

Residual current devices are devices 

which isolate electrical systems from the 
power supply system as soon as the 
residual current to ground exceeds a 
specific value.

Residual voltage U

res

The peak voltage value that occurs 

while discharge surge current is flowing 
via the terminal blocks of the SPD. 
Source: EN 61643-11:2002

Response

A response is when either:

– The peak value of the ohmic 

components of the current flowing 
through the arrester reaches 5 mA

– A voltage dip with an increase in the 

peak value of the current flowing 
through the arrester to 5 mA occurs

Selective residual current device

Selective residual current devices are 

time-delayed circuit breakers.

Short-circuit stability

Highest interference-free 

short-circuit current the SPD can 
withstand.

Source of interference 

A source of interference is the origin 

of disturbance variables. In principle, any 
electrical equipment, such as motors or 
fluorescent lamps, can be a source of 
interference.

Specialist

A specialist is a person who, because 

of their education, experience, and 
instruction, and their knowledge of 
relevant regulations, can assess any 
required operations and recognize any 
possible dangers.

Note: when considering a person's 

professional training, several years' 
experience in the relevant field can also 
be taken into account.

Spike

A relatively short single-polarity 

pulse.

Surface discharge surge arrester

The surface discharge surge arrester, 

according to DIN VDE 0845 Part 1, is a 
discharge path in which gas discharge is 
initiated by means of surface discharge.

Surge current of (8/20) 

s

Surge current with a rise time of 8 

and a decay time to half-value of 20 

s. 

Source: IEC 60060-1

340

PHOENIX CONTACT

Technical information

Explanation of terms

phoenixcontact-protection-html.html
background image

Surge current of (10/350) 

s

Surge current with a rise time of 10 

and a decay time to half-value of 350 

s. 

Source: IEC 62305-1

Surge protection equipment (SPE)

Surge protection equipment consists 

of surge protective devices and all 
equipment in telecommunications 
systems, including their cables, used for 
surge protection.

Surge protective device (SPD)

A device to limit surge voltages and 

discharge surge currents. It contains at 
least one non-linear voltage-limiting 
component.

Surge voltage

Any voltage with a peak value that 

exceeds the corresponding peak value of 
the maximum continuous voltage under 
normal operating conditions.
Source: EN 60664-1

Surge voltage category

Assignment of electrical equipment to 

the anticipated surge voltage.

Surge voltage of (1.2/50) 

s

Surge voltage with a rise time of 

1.2

s and a decay time to half-value of 

50

s. Source: IEC 60060-1 

1.2/50 surge voltage pulse according to IEC 60060-1

10/700 surge voltage pulse according to ITU-T K.44

10/1000 surge current pulse according to IEEE C62.41.1

Switching surge voltage

Surge voltage as a result of a switching 

operation.

Symmetrical interference

As shown in the figure, the 

disturbance variable moves from the 
source along one conductor to the 
potentially susceptible equipment and 
back along the other conductor. The 
terms “normal-mode interference” or 
“differential mode” are also used.

100

90

50

30

0

1,2

50

U

( % )

t ( us)

100

90

50

30

0

U

( % )

t ( us)

10

700

100

90

50

10

0

I

( % )

t ( us)

10

1000

Source of 

interference

Potentially 

susceptible 

equipment

Symmetrical interference voltage

Interference voltage between 

two wires of a cable (e.g., double cable) 
or between two connection points of 
electrical equipment for this cable type.

Symmetrical voltage, differential 
mode voltage

Voltage between two live conductors 

from one defined group.

Temperature range

Range between the minimum and 

maximum temperature that may be 
present at/in housing. For devices 
without self-heating, this value is the 
permissible ambient temperature. For 
devices with self-heating, these values are 
the maximum temperatures that may 
occur at/in the device during operation.

To ground

An electrically conductive part, e.g., 

the lightning protection system is 
connected to ground via a grounding 
system.

Transient

Describes a phenomenon or variable 

which changes during what is, in 
comparison to the time scale being 
observed, a short period of time between 
two consecutive stationary states.

Transients

Irregular and relatively short positive 

and/or negative voltage or current 
changes between two stationary states.

Varistors

A varistor is a bipolar non-linear 

resistor with a symmetrical voltage/
current characteristic curve and a 
resistance value which decreases as the 
voltage increases.

341

PHOENIX CONTACT

Technical information

Explanation of terms

phoenixcontact-protection-html.html
background image

342

PHOENIX CONTACT

Testlab, devices are also tested with regard to 
their electrical safety, mechanical influences, 
and their behavior in relation to 
environmental influences. Phoenix Testlab is 
also a notified body according to EMC 
Directive 2014/30/EU, R&TTE Directive 
1999/5/EC for radio equipment and 
telecommunications terminal equipment, and 
Radio Equipment Directive (RED) 
2014/53/EU. As a certification body (TCB, 
FCB, and RCB), Phoenix Testlab is also able to 
approve these products for the markets in the 
USA, Canada, and Japan.

Standards and regulations

All relevant standards and regulations are 

used as the basis for the development and 
maintenance of our products. 

International standards are subject to 

continuous changes as a result of 
harmonization and new developments. In line 
with this process, the current version of all 
standards that are relevant to our products is 
documented in the product area on our 
website at

 

phoenixcontact.net/products

.

Online product information service on 
the world wide web

Phoenix Contact is continuously extending 

its product range.

Within the scope of our product 

monitoring obligation, all products are subject 
to an improvement process.

The Internet is an ideal platform to quickly 

communicate new product developments and 
improvements to the market.

You can quickly access the relevant Phoenix 

Contact website for your region via 
phoenixcontact.com. There you will always 
find an up-to-date overview of products, 
solutions, and services from Phoenix 
Contact. This includes technical documents 
such as data sheets and user manuals, current 
driver and demo software, and a direct link to 
the relevant contact person.

for the marketing of these products 
within the EU

Where applicable, our products currently 

fall within the scope of the following 
directives: 

– 2014/35/EU 

Electrical equipment designed for use 
within certain voltage limits (Low Voltage 
Directive) 

– 2014/30/EU 

Electromagnetic compatibility 
(EMC Directive) 

– 2014/32/EU 

Measuring instruments 

– 2006/42/EC 

Safety of machinery 
(Machinery Directive) 

– 2014/34/EU 

Equipment and protective systems 
intended for use in potentially explosive 
atmospheres (ATEX Directive) 

– 1999/5/EC 

Radio Equipment and Telecommunications 
Terminal Equipment Directive (R&TTE)

– 2014/53/EU 

Radio equipment (RED) 

– 2011/65/EU 

RoHS Directive

The standards used as the basis for the 

aforementioned directives have been at the 
heart of our development standard for some 
time as a way of ensuring compliance with 
European directives. The numbers of the 
directives indicate their version at the time of 
publication. In the event of changes to 
directives and/or standards, our products will 
undergo conformity assessment again in good 
time and a new declaration of conformity will 
be issued promptly. The current declarations 
for each product can also be found in our 
download area.

Among the aforementioned European 

directives, the EMC Directive plays a 
particularly important role. It uses a legally 
binding directive as the basis for defining 
electromagnetic compatibility as a 
fundamental device property. European 
legislation therefore places great emphasis on 
the electromagnetic compatibility of devices 
and systems as a basic prerequisite for the 
error-free operation of machines and 
systems. As an international leader in the field 
of surge protection, Phoenix Contact has 
extensive expertise in EMC. This expertise 
and the experience gained over many years in 
the development and application of industrial 
interface and communication technology have 
resulted in an extremely high standard of 
quality for our products when it comes to 
electromagnetic compatibility. Our sister 
company, Phoenix Testlab, was founded in 
order to share this expertise with other 
companies. Phoenix Testlab GmbH is an 
independent, accredited service company, 
which carries out EMC testing in compliance 
with the European standards. At Phoenix 

Integrated management system

The objective of the Phoenix Contact 

integrated management system is to integrate 
all requirements pertaining to products, 
processes, and the organization.

Statutory and regulatory requirements, as 

well as those of international standards and 
our customers, are met and, in some cases, 
even exceeded in all phases of the product 
lifecycle.

The Phoenix Contact management system 

is monitored by internationally recognized 
independent bodies each year to ensure that 
quality, environmental protection, energy 
efficiency, and occupational safety have been 
integrated in conformance with the relevant 
requirements. Certification in accordance 
with international standards ISO 9001, ISO 
14001, ISO 50001, and BS OHSAS 18001 is 
the result of our corporate philosophy of 
meeting the needs of our customers, staff, 
and environment as best as possible. They 
serve as the basis for innovative products 
with the familiar high Phoenix quality 
standard, actively practiced environmental 
protection through efficient production and 
products that conserve resources, and 
responsibility in the field of occupational 
health and safety. It goes without saying that 
we integrate all further requirements of 
standards, international approvals or special 
customer requirements into our company 
processes. 

The result of this system is a building block 

for the success of the Phoenix Contact 
Group as well as its products and services.

CE marking

CE marking was introduced as an 

important instrument for the free movement 
of goods within the European single market. 
By applying the mark to a product, the 
manufacturer confirms its compliance with all 
EU directives applicable to this product. The 
EU directives describe the product 
characteristics with regard to device safety 
and the avoidance of risks. These are legally 
binding regulations of the European Union 
(EU), which means that the fulfillment of 
these requirements is a 

legal prerequisite 

Quality in quantity

Technical information

Appendix

phoenixcontact-protection-html.html
background image

60

200

For further information and full technical data, visit phoenixcontact.net/products

343

PHOENIX CONTACT

Touch-proof

Back of hand safety

Example: pressure actuation

Touch proofness

Finger safety

Back of hand safety

handle the machine.

The most important thing is that an area 

formed by an even envelope curve 30 mm in 
radius must surround the live parts. This 
area must be 

touch-proof

, i.e., the live 

parts of the electrical device must not be 
within reach of the VDE test finger 
according to IEC 60529/DIN VDE 0470-1 
(test finger).

Back of hand safety is specified for the 

“rest of the area” up to 100 mm around the 
operating element. 

Back of hand safety

 

means that when a force of 50 N is applied 
to a ball with a diameter of 50 mm, this 
does not come into contact with the live 
parts of the equipment. No special 
measures for ensuring contact safety are 
stipulated outside this area.

Note: Systems and equipment that are 

operated with SELV up to 25 V ~ or 60 V – 
are considered to be protected against 
“direct contact”.

According to § 5, Subsection 4 of the 

BGV A 2 regulations, there is no need to 
test the condition of the system prior to 
initial startup if the company has 
confirmation from the manufacturer or 
installer that the electrical systems and 
equipment conform to BGV A 2. The 
confirmation required relates to systems 
and equipment that have been installed and 
are ready for operation and can only be 
issued by the installer or installation 
company. The manufacturer of the electrical 
equipment can only issue a confirmation 
that products have been produced in 
accordance with the relevant 
electrotechnical DIN VDE regulations 
stipulated in BGV A 2. The installer must 
bear this in mind when selecting the 
equipment to be used.

In the field of connection technology, 

Phoenix Contact offers a wide range of 
products which are touch-proof or can be 

The accident prevention regulations 

BGV A 2 issued by the German employer's 
liability insurance association for precision 
mechanics and electrical engineering apply 
to the operators of electrical systems and 
are aimed at the prevention of electrical 
accidents by means of special safety 
requirements.

These regulations contain specifications 

regarding the safety distances for work, 
operation, and occasional handling in the 
proximity of “live parts” in low-voltage 
systems up to 1000 V ~ or 1500 V –.
– Work with live parts is only permitted 

once they have been de-energized. 
Operational activities are only permitted 
in the vicinity of live parts if these parts 
are de-energized or are protected against 
direct contact (§ 6). The following safety 
measures apply when working in the 
vicinity of live parts:

– Provision of the de-energized state for 

the duration of the work

– Ensure shock protection is in place in the 

form of covers or barriers during the 
work

– Assurance that proximity limits will not 

be violated (§ 7)
The term “occasional handling” has been 

introduced for the operation of elements 
such as pushbuttons, rocker arms or rotary 
buttons in the proximity of live parts.

In VDE 0105-1, this is covered by 

“operation with partial protection against 
direct contact”.

Detailed specifications for “occasional 

handling” can be found in 
DIN VDE 0106-100. This specifies to what 
degree live parts in the proximity of 
operating elements are to be protected 
against contact. The basis for this is the 
definition of a “protection area for 
occasional handling”; this is the area into 
which the user must reach in order to 

protected against contact by means of 
covers. Depending on the conditions, all of 
this must be taken into account when 
selecting the individual types of terminal 
blocks and accessories.

Technical information

Appendix

phoenixcontact-protection-html.html
background image

Quality features of insulating housings

Thermoplastics

The majority of our insulating housing is 

made from thermoplastic materials. Roughly 
speaking, these can be divided into 
amorphous and semi-crystalline substances. 
Thermoplastics are processed using the 
efficient and environmentally-friendly injection 
molding process. They have good recycling 
properties and can be re-used. We use many 
materials that are modified in different ways to 
meet the demanding requirements that 
electrical and electronic modules, devices, and 
systems have to meet with regard to their 
mechanical, thermal, and electrical properties.

Behavior of plastics under the 
influence of temperature (operating 
temperatures, mechanical influences)

All plastics undergo a process referred to as 

thermal aging when they are subjected to heat 
over long periods. This process causes 
changes in the mechanical and electrical 
properties of the material. External influences, 
e.g., radiation, additional mechanical, chemical 
or electrical stresses, amplify this effect. 
Special tests on samples can yield 
characteristic data which provides a good 
means of drawing comparisons between 
different plastics. However, applying these 
characteristics to an evaluation of molded 
plastic parts is only possible to a limited 
extent, and can only give the designer a rough 
guide when it comes to selecting a plastic 
material. This catalog uses the following 
assessment criteria: the 

RTI value

 according 

to UL746B/ANSI 746 B (elec. based on 
electric strength) and the 

Ti value

 according 

to IEC 60216-1 (based on a 50% reduction in 
tensile strength after 20,000 hours).

IEC 60947-7-1/EN 60947-7-1 specifies a 

permissible temperature increase of 45 K for 
terminal blocks under nominal load. Phoenix 
Contact terminal blocks fulfill this 
requirement. 

The properties of plastics are not only affected 

by the influence of heat as described above; they 
also undergo changes as a result of cold 
influences. When subjected to cold as well as 
low levels of humidity, plastics become 
increasingly brittle with the result that they are 
no longer capable of withstanding the same 
mechanical loads. As the table on the right 
shows, the plastics concerned can be used down 
to a temperature of -40°C, but only without a 
mechanical load. As far as the products 
presented in the catalog are concerned, it is the 
ambient temperature specified in each case that 
is to be regarded as definitive for operation. 
Regardless of the plastics used, this may be 
subject to further restrictions (e.g., limited to -
20°C) as a result of the components used or 
other restrictive parameters.

At very low temperatures, this means that 

any form of mechanical load on the plastic 
components must be avoided (e.g., mounting 
of products on/removal of products from the 
DIN rail, actuation of terminal points, 
locking/ejection of relays from bases, prizing 
out of jumpers, bending of cables and lines, 
etc.), as there is always an associated risk of 
damage. Unless otherwise indicated, it is 
recommended that you carry out the 
specified mounting/operational tasks in a 
temperature range from -10°C to +40°C.

Inflammability characteristics of 
plastics (UL 94)

The inflammability tests for plastics have 

been defined by the Underwriters Laboratory 
(USA) in regulation UL 94. This applies to all 
areas of application, particularly in electrical 
engineering. A horizontal or vertical test is 
carried out at the test laboratory to 
determine the inflammability of the plastic 
material with a naked flame. In order of 
increasing flame-retardant behavior, the 
evaluation classes are HB, V2, V1, V0, and 5V. 
Test results are recorded on “yellow cards” 
and are published annually in the 

Recognized 

Component Directory. 

Thermoplastics: 
non-reinforced polyamide, PA 

We use the modern, semi-crystalline 

polyamide insulation material, which has now 
become an essential component in electrical 
engineering and electronics. It has long 
occupied a leading position and is authorized 
for use by the relevant approval authorities 
such as the CSA, NEMKO, KEMA, PTB, SEV, 
UL, VDE, etc.

Polyamide has excellent electrical, 

mechanical, chemical, and other properties 
even at high operating temperatures. Brief 
peak temperatures of up to approximately 
200°C are permitted as a result of heat aging 
stabilization. Depending on the type (PA 4.6, 
6.6, 6.10, etc.), its melting point is in the region 
of 215°C to 295°C.

Polyamide absorbs moisture from its 

surroundings, on average 2.8%. This is not the 
embedded water of crystallization, however, 
but rather chemically bound H

2

O groups in 

the molecular structure. This makes the 
plastic flexible and resistant to breakage, even 
at temperatures as low as -40°C. PA belongs 
to flammability rating V2 to V0 according to 
UL 94.

Thermoplastics: polyester, PBT

We use the semi-crystalline thermoplastic 

polyester in non-reinforced and fiberglass-
reinforced variants for special applications 
which require increased dimensional and form 
stability. 

Apart from the high operating temperature, 

the material is characterized by excellent 
mechanical strength and hardness. Polyester 
does not absorb moisture from its 
surroundings. Therefore, PBT is particularly 
suitable for strips, for example, that are 
soldered onto PCBs and are subsequently 
required to pass a burn-in test where they are 
subjected to the influence of heat. PBT 
belongs to flammability rating V2 to V0 
according to UL 94.

Thermoplastics: polycarbonate, PC

Polycarbonate combines many advantages 

such as rigidity, impact strength, transparency, 
dimensional stability, good insulation 
properties, and resistance to heat.

The amorphous material only absorbs 

moisture to a very limited degree, and is used 
for items such as large, rigid electronic 
component housings.

In its transparent form, polycarbonate is 

particularly suitable for use as a material for 
cover profiles or marking materials.

PC has good resistance properties against 

mineral acids, saturated aliphatic 
hydrocarbons, gasoline, greases, and oils.

This material is not very resistant to 

solvents, benzene, alkalis, acetone, and 
ammonia. Strain cracks may result from 
contact with certain chemicals.

PC belongs to flammability rating V2 to V0 

according to UL 94.

Thermoplastics: 
polycarbonate fiber-reinforced, PC-F 

Compared to non-reinforced materials, 

fiber-reinforced polycarbonates feature 
greater rigidity, impact strength, and operating 
temperature. In other respects, their 
properties are largely identical to those of 
non-reinforced polycarbonate.

344

PHOENIX CONTACT

Technical information

Appendix

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

Properties

Unit/level

Polyamide

PA

Polyester

PBT

Polycarbonate 

PC

Polycarbonate 

PC-F

ABS

Operating temperature

RTI */**

°C

 105

 105

 125

 120

 80

Minimum temperature (without mechanical load)

°C

-40

-40

-40

-40

-40

Electric strength IEC 60243-1/DIN VDE 0303-21

kV/cm

600

400

> 300

850

Resistance to creepage IEC 60112/DIN VDE 0303-1

CTI...M

550

225

175

200

CTI...

600

225

175

175

600

Tropical and termite resistance

Good

Good

Good

Specific contact resistance

IEC 60093/VDE 0303 Part 30; IEC 60167/VDE 0303 Part 31

 cm

10

12

10

16

> 10

16

> 10

14

10

14

Surface resistance

IEC 60093/VDE 0303 Part 30; IEC 60167/VDE 0303 Part 31

 

10

10

10

13

> 10

14

10

13

Flammability rating according to UL 94

V2-V0

V0

V2-V0

V0

HB-V0

* According to UL 746 B/ANSI 746 B (elec.)

** Minimum value

Thermoplastics: ABS

We use the thermoplastic molding 

compound ABS for products which must have 
good impact and notched impact properties in 
addition to high mechanical stability and 
rigidity. The products are resistant to 
chemicals and stress cracking due to their 
special surface quality and hardness.

The characteristic thermal properties 

provide good dimensional stability at both low 
and high temperatures. Products made from 
ABS can be coated with metallic surfaces, e.g., 
nickel.

The flammability rating of the molding 

compound used is HB to V0 according to 
UL 94.

Dimensions: W

idth

/H

eight/

D

epth

W

H

D

W

D

H

Dimensions

Subject to changes that serve the purpose 

of technical progress.

In accordance with statutory regulations, 

our products are indicated with this 
footnote if they are intended for use in 
industrial environments. This means that 
the permitted limit values for residential 
applications may be exceeded in the event 
of conducted and emitted disturbance 
variables. In such cases, the operator may 
have to take additional safety measures in 
order to ensure electromagnetic 
compatibility in residential applications.

EMC: Class A product:

Note:

The dimensions “

W

idth/

H

eight/

D

epth” 

are defined as follows for all DIN-rail-
mountable products:

W

idth: measurement taken along the 

DIN rail

H

eight: measurement taken across the 

DIN rail

D

epth: measurement taken starting from 

the mounting plate and including the 
DIN rail 
NS 35/7.5 (EN 60715)
The width, height, and depth never change, 

even if the products shown in this catalog 
happen to be photographed from two 
different perspectives (horizontal or vertical).

To make things easier for you, one of the 

two symbols shown above has been included 
next to each product photo:

345

PHOENIX CONTACT

Technical information

Appendix

phoenixcontact-protection-html.html
background image

346

PHOENIX CONTACT

Connection cross section

strand)

 or flexible 

(fine-strand)

.

These values can be found in the product-

specific technical data.

The rated connection capacity of Phoenix 

Contact terminal blocks usually exceeds 
standard requirements, which specify that it 
must only be possible to connect one 
conductor with one of the two next smallest 
cross sections, excluding the rated cross 
section (standardized for the cross section 
range from 0.2 to 35 mm

2

).

In addition, conductors with a rated cross 

section can usually be wired with ferrules with 
plastic sleeve.

Phoenix Contact terminal blocks are 

The rated cross section of terminal blocks 

must be specified by the manufacturer 
according to IEC 60947-7-1. The rated cross 
section is the maximum conductor cross 
section that can be connected in single, multi 
or fine-strand versions subject to specific 
thermal, mechanical, and electrical 
requirements.

The manufacturer must also specify the 

rated connection capacity

, i.e., the area of 

connectable conductors as well as the 
number of conductors which can be 
connected simultaneously and the necessary 
preparation of the conductor ends. The 
conductors can be 

solid (single or multi-

designed to allow copper conductors to be 
connected to them untreated. “Special 
treatment” or the use of ferrules – both 
permitted according to IEC 60947-7-1 – are 
not required. If ferrules are nevertheless used 
to protect stranded conductors against 
splicing, the connection capacity of the 
stranded conductor is generally reduced by 
one level.

Structure and dimensions of connecting cables

Cross 

section

Single-stranded

Multi-stranded

Fine-stranded

American Wire Gauge [AWG]

Diameter 

max. 

dimension

Number of 

wires

Diameter 

max. 

dimension

Number of 

wires 

(minimum 

number)

Diameter 

max. 

dimension

Number of 

wires 

(guide 

value)

Gauge no.

Solid wires 

Stranded wires

[mm

2

]

AWG

[

 mm]

[circ. mils]

[mm

2

]

[

 mm]

[circ. mils]

[mm

2

]

0.2

0.5

1

24

0.51

404

0.21

0.5

0.9

1

1.1

7

1.1

16

20

0.81

1022

0.52

0.97

1111

0.56

0.75

1.0

1

1.2

7

1.3

24

18

1.02

1620

0.82

1.16

1600

0.82

1

1.2

1

1.4

7

1.5

32

(17)

1.15

2050

1.04

16

1.29

2580

1.31

1.50

2580

1.32

1.5

1.5

1

1.7

7

1.8

30

(15)

1.45

3260

1.65

14

1.63

4110

2.08

1.85

4100

2.09

2.5

1.9

1

2.2

7

2.3

50

(13)

1.83

5180

2.63

12

2.05

6530

3.31

2.41

6500

3.32

4

2.4

1

2.7

7

2.9

56

(11)

2.30

8230

4.17

10

2.59

10380

5.26

2.95

10530

5.37

6

2.9

1

3.3

7

3.9

84

(9)

2.91

13100

6.63

8

3.26

16510

8.37

3.73

16625

8.48

Extract from IEC 60947-1/EN 60947-1, Table 4 

The torque according to IEC and the recommended torque for Phoenix Contact terminal blocks are specified

Thread

Head screw with slot

Torque

Recommended 

tightening torque

[Nm]

[Nm]

M2.5 (M2.6)

0.4

0.4 - 0.5

M3

0.5

0.5 - 0.6

M3.5

0.8

0.8 - 1.0

M4

1.2

1.2 - 1.5

Standard IEC 60947-7-1/EN 60947-7-1/

DIN VDE 0611-1 specifies the test currents 
for the individual conductor cross sections 
listed in the adjacent table. The corresponding 
currents are listed with the connection data 
for the individual terminal blocks. The type 
tests of terminal blocks are based on this data.

Test currents according to IEC 60947-7-1/EN 60947-7-1, Table 5

Rated cross section

[mm

2

]

0.2

0.5

0.75

1.0

1.5

2.5

4

6

10

16

Test current

[A]

4

6

9

13.5

17.5

24

32

41

57

76

Tightening torque of terminal block screws

Current carrying capacity

IEC 60947-1/EN 60947-1, modified, Table 4 

specifies tightening torques for screw 
connections based on the screw size for 
electrical and mechanical type tests. 

Technical information

Appendix

phoenixcontact-protection-html.html
background image

j

DE

CCA

X

FR

C

+

CA

NL

F

DE

US

p

DE

x

GB

,

*

CA

US

NL

m

JP

A

US

!

FI

o

NO

a

CA

DE

z

PL

u

US

CA

w

BR

y

RU

g

IT

$

DE

d

KR

BY

KZ

RU

DE

l

US

NL

C

CA

K

AT

&

US

s

CH

,

CA

US

J

V

DE

A

US

DE

a

CA

US

u

US

CA

CA

f

US

US

CA

BY

KZ

RU

T

DE

CN

KR

For further information and full technical data, visit phoenixcontact.net/products

347

PHOENIX CONTACT

Certification bodies and approvals

Country 

code

Explosion protection

Country 

code

Marine classification societies

Country 

code

IECEE CB Scheme

(in combination with certifying body)

Interna-

tional

International 

Electrotechnical Commission

Interna-

tional

DNV GL - MARITIME 

CENELEC Certification Agreement 

(CCA inspection report)

(in combination with certifying body)

EU

ATEX Directive

EU

Bureau Veritas 

Canadian Standards Association (CSA)

DEKRA Certification B.V.

Germanischer Lloyd AG 

Canadian Standards Association (CSA)

- CSA approval for the USA - 

Physikalisch-Technische Bundesanstalt 

Lloyd's Register of Shipping

Canadian Standards Association

(CSA) Combined logo

- CSA approval for Canada and the USA -

KIWA Nederland B.V.

Nippon Kaiji Kyokai 

Underwriters Laboratories Inc. (UL) 

VTT Expert Services Oy 

Det Norske Veritas 

Underwriters Laboratories Inc. (UL) 

- UL approval for Canada -

IBExU Institut für Sicherheitstechnik 

GmbH

Polski Rejestr Statków 

Underwriters Laboratories Inc. 

(UL) Combined logo 

- UL approval for the USA and Canada -

TÜV Rheinland do Brasil

Russian Maritime Register of Shipping 

INSIEME PER LA QUALITA'E LA 

SICUREZZA

Technischer Überwachungsverein Nord

Korean Register of Shipping

Eurasian Conformity

DEKRA EXAM GmbH

American Bureau of Shipping

DEKRA Certification B.V.

Canadian Standards Association (CSA)

Österreichischer Verband für 

Elektrotechnik

Canadian Standards Association (CSA)

- CSA approval for the USA - 

electrosuisse SEV 

Verband für Elektro-, 

Energie- und Informationstechnik

Canadian Standards Association

(CSA) Combined logo

- CSA approval for Canada and the USA -

Verband Deutscher Elektrotechniker e.V. 

(VDE) 

– Approval of drawings 

– Reports with production monitoring

Underwriters Laboratories Inc. (UL) 

Berufsgenossenschaft (BG)

GS Tested safety

Underwriters Laboratories Inc. (UL) 

- UL approval for Canada -

Intertek ETL Listed

- Approval for the USA -

Underwriters Laboratories Inc. 

(UL) Combined logo 

- UL approval for the USA and Canada -

Intertek ETL Listed

- Approval for Canada -

FM Approvals

Intertek ETL Listed

- Approval for the USA and Canada -

Eurasian Conformity for Ex-products

TÜV Rheinland Industrie Service GmbH

China Compulsory Certification

Korea Communications Commission

Certification bodies and safety marks

Technical information

Appendix

phoenixcontact-protection-html.html
background image

,

348

PHOENIX CONTACT

Rated surge voltages for equipment that is directly supplied by the low-voltage 

network (extract from Table 1)

Nominal voltage of the power supply system

 

1

) (mains) as per IEC 60038 

3

)

Conductor-neutral conductor voltage 

derived from the total nominal AC 

voltage or nominal DC voltage

Rated surge voltage 

2

)

[V]

Three-phase 

Single-phase 

Overvoltage category 

4

)

[V]

[V]

[V]

 I

II

III

IV

120 to 240

50

330

500

800

1500

100

500

800

1500

2500

150

800

1500

2500

4000

230/400

277/480

300

1500

2500

4000

6000

 400/690

600

2500

4000

6000

8000

1000

1000

4000

6000

8000

12000

1

) Refer to Annex B for application in existing deviating low-voltage networks and their nominal voltages.

2

) Equipment with this rated surge voltage may be used in systems according to IEC 60364-4-443.

3

) The slash, i.e., /, indicates a three-phase four-wire system. The lower value is the conductor-to-neutral-conductor voltage, whereas the higher 

value is the conductor-to-conductor voltage. When only one value is specified, it refers to a three-phase three-conductor system, and indicates 

the conductor-to-conductor voltage.

4

) Refer to 2.2.2.1.1 for an explanation of overvoltage categories.

Minimum clearances for overvoltages (extract from Table 2)

Required rated 

impulse voltage 

1

5

)

Condition A

Non-homogeneous field (refer to 3.15)

Condition B

Homogeneous field (refer to 3.14)

Pollution degree 

6

)

Pollution degree 

6

)

1

2

3

1

2

3

[kV]

 [mm]

[mm]

[mm]

[mm]

[mm]

[mm]

0.33 

2

)

0.01

0.2

 

3

4

)

0.8 

4

)

0.01

0.2

 

3

4

)

0.8 

4

)

0.40

0.02

0.02

0.5 

2

)

0.04

0.04

0.60

0.06

0.06

0.80 

2

)

0.10

0.10

1.0

0.15

0.15

1.2

0.25

0.25

0.2

1.5 

2

)

0.5

0.5

0.3

0.3

2.0

1.0

1.0

1.0

0.45

0.45

2.5 

2

)

1.5

1.5

1.5

0.6

0.6

3.0

2.0

2.0

2.0

0.8

0.8

4.0 

2

)

3

3

3

1.2

1.2

1.2

5.0

4

4

4

1.5

1.5

1.5

6.0 

2

)

5.5

5.5

5.5

2

2

2

8.0 

2

)

8

8

8

3

3

3

10

11

11

11

3.5

3.5

3.5

12

2

)

14

14

14

4.5

4.5

4.5

15

18

18

18

5.5

5.5

5.5

20

25

25

25

8

8

8

25

33

33

33

10

10

10

30

40

40

40

12.5

12.5

12.5

40

60

60

60

17

17

17

50

75

75

75

22

22

22

60

90

90

90

27

27

27

80

130

130

130

35

35

35

100

170

170

170

45

45

45

1

) This voltage is:

– For function insulation: the highest surge voltage expected for the clearance

– For basic insulation, if influenced directly or considerably by transient overvoltages from the low-voltage network: the rated surge voltage 

of the equipment

– For a different basic insulation: the highest surge voltage possible in the circuit.

2

) Preferred values

3

) For PCBs, the values of pollution degree 1 are applicable, except that no deviation below the value of 0.04 mm is permitted, as specified in 

Table 4.

4

) Minimum clearances for pollution degrees 2 and 3 are based on the corresponding creepage distances. This resistance is reduced due to the 

effects of humidity.

5

) Values can be interpolated for parts or circuits within equipment that are subjected to surge voltages.

6

) The distances for pollution degree 4 are equal to those for pollution degree 3, except that the minimum clearance is 1.6 mm.

Schematic for determining clearances

Altitude correction factors

(extract from Table A.2)

Altitude [m]

Normal air pressure 

[kPa]

Multiplication factor for 

distances

2000

3000

4000

80.0

70.0

62.0

1.00

1.14

1.29

5000

6000

7000

54.0

47.0

41.0

1.48

1.70

1.95

8000

9000

10000

35.5

30.5

26.5

2.25

2.62

3.02

15000

20000

12.0

5.5

6.67

14.50

Dimensioning of clearances

Nominal voltage of the 

power supply

Rated 

surge 

voltage

Rated surge voltage 

according to Table 1

Overvoltage 

category

Minimum clearance L 

according to Table 2

Pollution 

degree

Altitude 

> 2000 m 

above sea 

level

Multiply L with altitude 

correction factor 

according to Table A2 

Surge 

voltage test

No

Rating acc. 

to case A

Yes

Clearance L

Technical information

Appendix

phoenixcontact-protection-html.html
background image

For further information and full technical data, visit phoenixcontact.net/products

349

PHOENIX CONTACT

Schematic for determining creepage 
distances

Single-phase three or two-conductor AC or DC voltage 

systems (extract from Table 3 a)

Nominal voltage 

of the power 

supply system 

(mains) *)

 Voltages for Table 4

For conductor-to-

conductor 

insulation 

1

)

For conductor-to-

ground 

insulation 

1

)

All systems

Three-conductor 

systems

center point grounded

[V]

[V]

[V]

12.5

12.5

24

25

25

30

32

42

48

50 **)

50

60

63

30 - 60

63

32

100 **)

100

110

120

125

150 **)

160

220

250

110 - 220

220 - 240

250

125

300 **)

320

220 - 440

500

250

600 **)

630

480 - 960

1000

500

1000 **)

1000

1

) Conductor-to-ground insulation levels for non-grounded systems 

or those grounded through impedance correspond to conductor-

to-conductor insulation levels as the operating voltage of every 

conductor to ground can, in practice, reach the conductor-to-

conductor voltage. This is based on the fact that the actual voltage 

to ground is determined by the insulation resistance and 

capacitive reactance of each conductor to ground. Therefore, a 

low (but permissible) insulation resistance of a conductor can 

practically ground this and raise the two others to conductor-to-

conductor voltage to ground.

*) Refer to 2.2.1 for correlation with the rated voltage.

**) These values correspond to the values in Table 1.

Three-phase four or three-conductor AC voltage systems 

(extract from Table 3 b)

Nominal 

voltage of 

the power 

supply 

system 

(mains) *)

 Voltages for Table 4

For 

conductor-

to-conductor 

insulation

All systems

Insulation for conductor to ground

Three-phase 

four-conductor 

systems with 

grounded 

neutral 

conductor

2

)

Three-phase 

three-

conductor 

systems non-

grounded

 1

)

 

or 

conductor 

grounded

[V]

[V]

[V]

[V]

60

63

32

63

110/120/127

125

80

125

150 **)

160

160

208

200

125

200

220/230/240

250

160

250

300 **)

320

320

380/400/415

400

250

400

440

500

250

400

480/500

500

320

500

575

630

400

630

600 **)

630

630

660/690

630

400

630

720/830

800

500

800

960

1000

630

1000

1000 **)

1000

1000

1

) Conductor-to-ground insulation levels for non-grounded systems 

or those grounded through impedance correspond to conductor-

to-conductor insulation levels as the operating voltage of every 

conductor to ground can, in practice, reach the conductor-to-

conductor voltage. This is based on the fact that the actual voltage 

to ground is determined by the insulation resistance and 

capacitive reactance of each conductor to ground. Therefore, a 

low (but permissible) insulation resistance of a conductor can 

practically ground this and raise the two others to conductor-to-

conductor voltage to ground.

2

) For equipment designed for use in three-phase four-conductor 

and three-phase three-conductor systems, grounded as well as 

non-grounded, only the values for three-conductor systems may 

be used.

*) Refer to 2.2.1 for correlation with the rated voltage.

**) These values correspond to the values in Table 1.

Creepage distances to prevent failures occurring due to creepage (extract from Table 4)

Voltage 

1

)

r.m.s. value

Minimum creepage distances

1

) This voltage is:

a) For function insulation: the working 

voltage.

b) For basic and additional insulation 

of a circuit supplied directly by the 

low-voltage network: either the 

voltage selected from Table 3 a or 

3 b on the basis of the rated 

voltage of the equipment or the 

rated insulation voltage.

c) For basic and additional insulation 

of systems, equipment, and 

internal circuits which are not 

supplied directly from the mains: 

the highest r.m.s. value of the 

voltage that, within the bounds of 

the rated data, can occur in the 

system, the equipment or the 

internal circuit, when supplied with 

rated voltage and in the case of the 

most unfavorable combination of 

operating conditions.

2

) With pollution degree 3, insulation 

material group III b is not 

recommended for use if voltages 

are greater than 630 V.

Printed circuits

Pollution degree

Pollution degree

1

2

1

2

3

All insulation material 

groups

All insulation material 

groups except III b

All insulation material 

groups

Insulation material group

Insulation material group

I

II

III

I

II

III 

2

)

[V]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

10

12.5

16

0.025

0.025

0.025

0.04

0.04

0.04

0.08

0.09

0.10

0.4

0.42

0.45

0.4

0.42

0.45

0.4

0.42

0.45

1.00

1.05

1.10

1.00

1.05

1.10

1.00

1.05

1.10

20

25

32

0.025

0.025

0.025

0.04

0.04

0.04

0.110

0.125

0.140

0.48

0.5

0.53

0.48

0.5

0.53

0.48

0.5

0.53

1.20

1.25

1.30

1.20

1.25

1.30

1.20

1.25

1.30

40

50

63

0.025

0.025

0.040

0.04

0.04

0.63

0.16

0.18

0.20

0.56

0.6

0.63

0.8

0.85

0.9

1.1

1.2

1.25

1.4

1.5

1.6

1.6

1.7

1.8

1.8

1.9

2.0

80

100

125

0.063

0.10

0.16

0.10

0.16

0.25

0.22

0.25

0.28

0.67

0.71

0.75

0.95

1.0

1.05

1.3

1.4

1.5

1.7

1.8

1.9

1.9

2.0

2.1

2.1

2.2

2.4

160

200

250

0.25

0.40

0.56

0.4

0.63

1.0

0.32

0.42

0.56

0.8

1.0

1.25

1.1

1.4

1.8

1.6

2.0

2.5

2.0

2.5

3.2

2.2

2.8

3.6

2.5

3.2

4.0

320

400

500

0.75

1.0

1.3

1.6

2.0

2.5

0.75

1.00

1.30

1.6

2.0

2.5

2.2

2.8

3.6

3.2

4.0

5.0

4.0

5.0

6.3

4.5

5.6

7.1

5.0

6.3

8.0

630

800

1000

1.8

2.4

3.2

3.2

4.0

5.0

1.80

2.40

3.20

3.2

4.0

5.0

4.5

5.6

7.1

6.3

8.0

10

8.0

10.0

12.5

9

11

14

10.0

12.5

16.0

1250

1600

2000

4.20

5.60

7.50

6.3

8

10

9

11

14

12.5

16

20

16

20

25

18

22

28

20

25

32

2500

3200

4000

10

12.5

16

12.5

16

20

18

22

28

25

32

40

32

40

50

36

45

56

40

50

63

5000

6300

8000

20

25

32

25

32

40

36

45

56

50

63

80

63

80

100

71

90

110

80

100

125

10000

40

50

71

100

125

140

160

Dimensioning of creepage distances

Nominal mains 

voltage of the power 

supply

Rated AC/DC voltage

Pollution 

degree

Minimum creepage 

distance K acc. to 

Table 4

Insulation 

material

Clearance 

L

Pollution degree 1

Yes

No

Increase K 

to L

Yes

K < L

K < L

acc. to case A

No

No

Yes

Creepage distance K

Increase K to 

L acc. to case 

A

Technical information

Appendix

phoenixcontact-protection-html.html
background image

Type

Order No. Page

Type

Order No. Page

Type

Order No. Page

Type

Order No. Page

A

ADAPTER KOAX TYP F

2880972

180

B

BATTERY MOUNTING CASE

2320458

289

BATTERY MOUNTING KIT

2320788

289

BLT-T2-1S-320-UT

2906101

69

BLT-T2-320-UT

2906100

69

BNC-V 50

2805041

177

BNC-V 75

2805070

177

BT-1S-230AC/A

2803409

73

BT-1S-230AC/O

2800625

73

C

C-SAT-BOX

2880561

180

C-TV-SAT

2856993

181

C-TV/HIFI

2857002

181

C-UB/E

2763701

177

C-UFB- 5DC/E

2782300

177

C-UFB- 5DC/E 75

2763604

177

C-UFB-24DC/E

2782313

177

CB 1/10-1/10 UT-BE

2801305

331

CB 1/6-2/4 PT-BE

2800929

331

CB E1 24DC/10A S-C P

2800928

323

CB E1 24DC/10A S-R P

2800914

323

CB E1 24DC/1A NC P

2800915

323

CB E1 24DC/1A NO P

2800901

322

CB E1 24DC/1A S-C P

2800922

323

CB E1 24DC/1A S-R P

2800908

323

CB E1 24DC/2A NC P

2800916

323

CB E1 24DC/2A NO P

2800902

322

CB E1 24DC/2A S-C P

2800923

323

CB E1 24DC/2A S-R P

2800909

323

CB E1 24DC/3A NC P

2800917

323

CB E1 24DC/3A NO P

2800903

322

CB E1 24DC/3A S-C P

2800924

323

CB E1 24DC/3A S-R P

2800910

323

CB E1 24DC/4A NC P

2800918

323

CB E1 24DC/4A NO P

2800904

322

CB E1 24DC/4A S-C P

2800925

323

CB E1 24DC/4A S-R P

2800911

323

CB E1 24DC/6A NC P

2800919

323

CB E1 24DC/6A NO P

2800905

322

CB E1 24DC/6A S-C P

2800926

323

CB E1 24DC/6A S-R P

2800912

323

CB E1 24DC/8A S-C P

2800927

323

CB E1 24DC/8A S-R P

2800913

323

CB PT BRIDGE

2801014

322

CB S-BE

2905067

331

CB TM1 0.5A F1 P

2800857

330

CB TM1 0.5A M1 P

2800846

329

CB TM1 0.5A SFB P

2800835

269

CB TM1 10A F1 P

2800865

330

CB TM1 10A M1 P

2800854

329

CB TM1 10A SFB P

2800843

328

CB TM1 12A F1 P

2800866

330

CB TM1 12A M1 P

2800855

329

CB TM1 12A SFB P

2800844

328

CB TM1 16A F1 P

2800867

330

CB TM1 16A M1 P

2800856

329

CB TM1 16A SFB P

2800845

328

CB TM1 1A F1 P

2800858

330

CB TM1 1A M1 P

2800847

329

CB TM1 1A SFB P

2800836

269

CB TM1 2A F1 P

2800859

330

CB TM1 2A M1 P

2800848

329

CB TM1 2A SFB P

2800837

269

CB TM1 3A F1 P

2800860

330

CB TM1 3A M1 P

2800849

329

CB TM1 3A SFB P

2800838

269

CB TM1 4A F1 P

2800861

330

CB TM1 4A M1 P

2800850

329

CB TM1 4A SFB P

2800839

269

CB TM1 5A F1 P

2800862

330

CB TM1 5A M1 P

2800851

329

CB TM1 5A SFB P

2800840

269

CB TM1 6A F1 P

2800863

330

CB TM1 6A M1 P

2800852

329

CB TM1 6A SFB P

2800841

269

CB TM1 8A F1 P

2800864

330

CB TM1 8A M1 P

2800853

329

CB TM1 8A SFB P

2800842

328

CB TM2 0.5A F1 P

2800890

330

CB TM2 0.5A M1 P

2800879

329

CB TM2 0.5A SFB P

2800868

328

CB TM2 10A F1 P

2800898

330

CB TM2 10A M1 P

2800887

329

CB TM2 10A SFB P

2800876

328

CB TM2 12A F1 P

2800899

330

CB TM2 12A M1 P

2800888

329

CB TM2 12A SFB P

2800877

328

CB TM2 16A F1 P

2800900

330

CB TM2 16A M1 P

2800889

329

CB TM2 16A SFB P

2800878

328

CB TM2 1A F1 P

2800891

330

CB TM2 1A M1 P

2800880

329

CB TM2 1A SFB P

2800869

328

CB TM2 2A F1 P

2800892

330

CB TM2 2A M1 P

2800881

329

CB TM2 2A SFB P

2800870

328

CB TM2 3A F1 P

2800893

330

CB TM2 3A M1 P

2800882

329

CB TM2 3A SFB P

2800871

328

CB TM2 4A F1 P

2800894

330

CB TM2 4A M1 P

2800883

329

CB TM2 4A SFB P

2800872

328

CB TM2 5A F1 P

2800895

330

CB TM2 5A M1 P

2800884

329

CB TM2 5A SFB P

2800873

328

CB TM2 6A F1 P

2800896

330

CB TM2 6A M1 P

2800885

329

CB TM2 6A SFB P

2800874

328

CB TM2 8A F1 P

2800897

330

CB TM2 8A M1 P

2800886

329

CB TM2 8A SFB P

2800875

328

CBM E4 24DC/0.5-10A NO-R

2905743

314

CBM E8 24DC/0.5-10A NO-R

2905744

314

CBMC E4 24DC/1-10A NO

2906032

316

CBMC E4 24DC/1-10A NO-C

2908716

317

CBMC E4 24DC/1-4A NO

2906031

316

CBMC E4 24DC/1-4A NO-C

2908713

317

CHECKMASTER 2

2905256

195

CM 2-PA-CTM

2905282

195

CM 2-PA-FLT/VAL-CP/SEC

2905283

195

CM 2-PA-PT/A

2907891

195

CM 2-PA-PT/PLT

2905284

195

CM 2-PA-PT4/PLT3S

2907019

195

CM 2-PA-SEC-HYBRID

2907889

195

CM 2-PA-TTC

2908707

195

CM 2-PA-VAL-MS

2905265

195

CN-LAMBDA/4-0.47-BB

2800021

178

CN-LAMBDA/4-0.47-SB

2800022

178

CN-LAMBDA/4-2.25-BB

2801057

178

CN-LAMBDA/4-2.25-SB

2801056

178

CN-LAMBDA/4-5.9-BB

2838490

179

CN-LAMBDA/4-5.9-SB

2800023

179

CN-UB-280DC-3-BB

2801050

176

CN-UB-280DC-3-SB

2801051

176

CN-UB-70DC-6-BB

2803166

176

CN-UB-70DC-6-SB

2803153

176

CN-UB/E

2763691

177

CN-UB/E-BB

2817686

177

CN-UB/MP

2818135

176

CN-UB/MP-90DEG-50

2803137

176

CSMA-LAMBDA/4-2.0-BS-SET

2800491

179

CT  1-10-ES

2765547

169

CT 10-2/2-GS

2765398

168

CT 10-2/2-GS/3E

2765408

168

CT 10-2/2-GS/3E-110AC

2920829

168

CT 10-MB/ 3

2765372

169

CT 10-MB/10

2765385

169

CT 10-TL

2765356

169

CT-KDT

2765518

169

CT-TERMIBLOCK 10 DA

0441711

169

CTM 10-MAG

2838610

169

CTM 1X2- 12DC

2838597

102

CTM 1X2- 24DC

2838513

102

CTM 1X2- 60DC

2838568

102

CTM 1X2-110AC

2838539

166

CTM 2X1- 12DC

2838584

119

CTM 2X1- 24DC

2838500

119

CTM 2X1- 60DC

2838542

119

CTM 2X1-110AC

2838526

166

CTM 2X1-180DC-GS

2838636

167

CTM 2X1-180DC-GS-P

2838623

167

CTM EST

2838649

102

CTM ISDN

2838555

167

D

D-LAN-19"-12

2880150

143

D-LAN-19"-16

2880147

143

D-LAN-19"-20

2880134

143

D-LAN-19"-24

2838791

143

D-LAN-19"-4

2880176

143

D-LAN-19"-8

2880163

143

D-LAN-19"-D-P

2880192

143

D-LAN-CAT.5-FP

2800723

143

D-UFB-PB

2880642

155

DK-BIC-35

2749880

77

DT-LAN-CAT.6+

2881007

142

DT-TELE-RJ45

2882925

162

DT-TELE-SHDSL

2801593

162

DT-UFB-485/BS

2920612

147

DT-UFB-IB-RB0

2800056

159

DT-UFB-IB-RBI

2800055

159

DT-UFB-V24/S-9-SB

2803069

144

E

EC-E  0,5A DC24V

0903041

327

EC-E  1A DC24V

0903042

327

EC-E  2A DC24V

0903043

327

EC-E  3A DC24V

0903044

327

EC-E  4A DC24V

0903045

327

EC-E  6A DC24V

0903046

327

EC-E  8A DC24V

0903047

327

EC-E 10A DC24V

0903048

327

EC-E 12A DC24V

0903049

327

EC-E1 0,5A

0903022

326

EC-E1 10A

0903030

326

EC-E1 12A

0903031

326

EC-E1 1A

0903023

326

EC-E1 2A

0903024

326

EC-E1 3A

0903025

326

EC-E1 4A

0903026

326

EC-E1 6A

0903028

326

EC-E1 8A

0903029

326

EC-E4 0,5A

0903040

326

EC-E4 10A

0903038

326

EC-E4 12A

0903039

326

EC-E4 1A

0903032

326

EC-E4 2A

0903033

326

EC-E4 3A

0903034

326

EC-E4 4A

0903035

326

EC-E4 6A

0903036

326

EC-E4 8A

0903037

326

ECP  4

0912034

325

ECP  6

0912033

325

ECP 1-2

0912018

325

ECP 10

0912020

325

ECP 2

0911034

325

ECP 3

0911047

325

ECP 3-6

0916536

325

ECP 8

0912019

325

ECP-E  1A

0900113

324

ECP-E  2A

0900210

324

ECP-E  3A

0900317

324

ECP-E  4A

0900414

324

ECP-E  6A

0900618

324

ECP-E  8A

0900812

324

ECP-E 10A

0901002

324

ECP-E-12A

0900126

324

ECP-E2-10A

0900100

325

ECP-E2-12A

0900207

325

ECP-E2-1A

0900139

325

ECP-E2-2A

0900236

325

ECP-E2-3A

0900333

325

ECP-E2-4A

0900430

325

ECP-E2-6A

0900634

325

ECP-E2-8A

0900838

325

ECP-E3 10A

0912050

325

ECP-E3 12A

0912052

325

ECP-E3 1A

0912041

325

ECP-E3 2A

0912042

325

ECP-E3 3A

0912043

325

ECP-E3 4A

0912044

325

ECP-E3 6A

0912046

325

ECP-E3 8A

0912048

325

EML (20XE)R

0803452

77

EML (20XE)R YE

0803453

77

F

F-MS 12

2817987

55

F-MS 12 ST

2817990

63

F-MS 12-UD ST

2858328

63

F-MS 12/FM

2817974

55

F-MS 2200/30 ST

2805392

56

F-MS-T1/T2 50 ST

2800191

36

FBS  2-6

3030336

331

FBS  2-6 BU

3036932

331

FBS  2-6 GY

3032237

331

FBS  3-6

3030242

331

FBS  3-6 BU

3036945

331

FBS  3-6 GY

3032240

331

FBS  4-6

3030255

331

FBS  4-6 BU

3036958

331

FBS  4-6 GY

3032279

331

FBS  5-6

3030349

331

FBS  5-6 BU

3036961

331

FBS  5-6 GY

3032266

331

FBS 10-6

3030271

331

FBS 10-6 BU

3032198

331

FBS 10-6 GY

3032253

331

FBS 20-6

3030365

331

FBS 20-6 BU

3032208

331

FBS 50-6

3032224

331

FBS 50-6 BU

3032211

331

FBST 500 TMC-N GY

0901028

326

FBST 500-PLC BU

2966692

326

FBST 500-PLC RD

2966786

326

FLT-ISG-100-EX

2905579

78

FLT-ISG-BR-11

2905580

79

FLT-ISG-BR-14

2905581

79

FLT-ISG-BR-18

2905582

79

FLT-ISG-BR-22

2905583

79

FLT-ISG-BR-26

2905757

79

FLT-ISG-BR-30

2905758

79

FLT-ISG-BR-33

2905759

79

FLT-ISG-BR-36

2905760

79

FLT-ISG-BR-39

2905761

79

FLT-ISG-BR-42

2905762

79

FLT-ISG-BR-48

2905763

79

FLT-ISG-BR-56

2905764

79

FLT-ISG-BR-62

2905765

79

FLT-ISG-CA-100

2905589

79

FLT-ISG-CA-200

2905590

79

FLT-ISG-CA-300

2905591

79

FLT-ISG-PL-11

2905584

79

FLT-ISG-PL-14

2905586

79

FLT-ISG-PL-18

2905587

79

FLT-ISG-PL-22

2905588

79

FLT-ISG-PL-26

2905745

79

FLT-ISG-PL-30

2905746

79

FLT-ISG-PL-33

2905747

79

FLT-ISG-PL-36

2905754

79

FLT-ISG-PL-39

2905755

79

FLT-ISG-PL-42

2905756

79

FLT-SEC-H-T1-1C-264/25-FM

2801615

28

FLT-SEC-H-T1-1C-440/25-FM

2907259

28

FLT-SEC-H-T1-264/25-P

2905968

28

FLT-SEC-H-T1-3C-264/25-FM

2905871

28

FLT-SEC-H-T1-3C-440/25-FM

2907260

28

Index

Alphabetical

350

PHOENIX CONTACT

phoenixcontact-protection-html.html
background image

Type

Order No. Page

Type

Order No. Page

Type

Order No. Page

Type

Order No. Page

FLT-SEC-H-T1-440/25-P

2907261

28

FLT-SEC-P-T1-1C-264/50-FM

2907387

35

FLT-SEC-P-T1-1C-350/25-FM

2905414

33

FLT-SEC-P-T1-1C-440/35-FM

2905987

30

FLT-SEC-P-T1-1S-264/50-FM

2907388

35

FLT-SEC-P-T1-1S-350/25-FM

2905415

33

FLT-SEC-P-T1-264/50-P

2907391

34

FLT-SEC-P-T1-2C-350/25-FM

2905416

32

FLT-SEC-P-T1-2S-350/25-FM

2905418

32

FLT-SEC-P-T1-350/25-P

2905422

31

FLT-SEC-P-T1-3C-264/50-FM

2907390

34

FLT-SEC-P-T1-3C-350/25-FM

2905419

31

FLT-SEC-P-T1-3C-440/35-FM

2905988

29

FLT-SEC-P-T1-3S-264/50-FM

2909589

34

FLT-SEC-P-T1-3S-350/25-FM

2905421

31

FLT-SEC-P-T1-3S-440/35-FM

2908264

29

FLT-SEC-P-T1-440/35-P

2905989

29

FLT-SEC-P-T1-N/PE-350/100-FM

2905472

33

FLT-SEC-P-T1-N/PE-350/100-P

2905473

31

FLT-SEC-P-T1-N/PE-440/100-FM

2907262

30

FLT-SEC-P-T1-N/PE-440/100-P

2907263

29

FLT-SEC-T1+T2-1C-350/25-FM

2905465

44

FLT-SEC-T1+T2-1S-350/25-FM

2905466

43

FLT-SEC-T1+T2-2C-350/25-FM

2905467

43

FLT-SEC-T1+T2-2S-350/25-FM

2905468

43

FLT-SEC-T1+T2-3C-350/25-FM

2905469

42

FLT-SEC-T1+T2-3S-350/25-FM

2905470

42

FLT-SEC-T1-350/25-P

2905471

42

FOC-SJ:14-ST/.../.../...

1417723

190

FUSE  5A/32V FK-1

2908367

299

FUSE 10A/32V  FK1

2908364

305

FUSE 15A/32V FK1

2908360

286

FUSE 15A/32V FKS ATO

2908361

294

FUSE 25A/32V ATOF

2908366

286

FUSE 25A/32V FKS

2908363

305

G

GEB-SET-T1/T2 TAE/TV-SAT

2801022

76

I

IFS-BT-PROG-ADAPTER

2905872

291

IFS-CONFSTICK

2986122

290

IFS-CONFSTICK-L

2901103

290

IFS-MINI-DIN-DATACABLE

2320487

291

IFS-OPEN-END-DATACABLE

2320450

291

IFS-RS232-DATACABLE

2320490

291

IFS-USB-DATACABLE

2320500

290

K

KBL-SAT/20

2880985

180

L

LIT 1X2-24

2804610

100

LIT 2X1-24

2804636

117

LIT 2X2-24

2804623

100

LIT 4-12

2804704

123

LIT 4-24

2804678

123

LIT 4X1-24

2804649

117

LM-S-A/C-3S-ETH

2800618

191

LM-S-C-3LS

2800617

191

LM-S-LS-H

2800616

190

M

ME 17,5 TBUS 1,5/ 5-ST-3,81 GN

2709561

234

ME 6,2 TBUS-2 1,5/5-ST-3,81KMGY

2969401

123

MINI MCR-SL-V8-FLK 16-A

2811268

100

MINI-BAT/12DC/1.6AH

2866572

305

MINI-BAT/12DC/2.6AH

2866569

305

MINI-BAT/24DC/0.8AH

2866666

304

MINI-BAT/24DC/1.3AH

2866417

302

MINI-DC-UPS/12DC/4

2866598

301

MINI-DC-UPS/24DC/2

2866640

301

MINI-PS- 10- 42AC/15-60DC/3

2320199

257

MINI-PS- 12- 24DC/ 5-15DC/2

2320018

256

MINI-PS- 12- 24DC/24DC/1

2866284

256

MINI-PS- 12- 24DC/48DC/0.7

2320021

257

MINI-PS- 48- 60DC/24DC/1

2866271

257

MINI-PS-100-240AC/ 5DC/3

2938714

236

MINI-PS-100-240AC/10-15DC/2

2938756

236

MINI-PS-100-240AC/10-15DC/8

2866297

237

MINI-PS-100-240AC/24DC/1.3

2866446

234

MINI-PS-100-240AC/24DC/1.5/EX

2866653

237

MINI-PS-100-240AC/24DC/2

2938730

235

MINI-PS-100-240AC/24DC/4

2938837

235

MINI-PS-100-240AC/24DC/C2LPS

2866336

235

MINI-PS-100-240AC/2X15DC/1

2938743

237

MINI-SCREW-USB-DATACABLE

2908217

283

MINI-SYS-PS-100-240AC/24DC/1.5

2866983

234

MNT-1 CH II

2882255

74

MNT-1 D

2882200

74

MNT-1 D/WH

2882213

74

MNT-NET B/F

2882226

74

MNT-TAE D

2882381

74

MNT-TAE D/WH

2882394

74

MNT-TEL B/F

2882404

75

MNT-TELE E

2882417

75

MNT-TELE S/WH

2880901

75

MNT-TV-SAT B/F

2882307

75

MNT-TV-SAT D

2882284

75

MNT-TV-SAT D/WH

2882297

75

MPB 18/1- 2

2809209

77

MPB 18/1- 3

2809212

77

MPB 18/1- 4

2809225

77

MPB 18/1- 5

2817864

77

MPB 18/1- 6

2748564

77

MPB 18/1- 8

2748577

77

MPB 18/1- 9

2748580

77

MPB 18/1-12

2748593

77

MPB 18/1-57

2809238

77

MPB 18/1-6/35

2908705

77

MPB 18/1-8/35

2908704

77

N

NEF 1- 1

2794123

187

NEF 1- 3

2794110

187

NEF 1- 6

2783082

187

NEF 1-10

2788977

187

P

PA-CASE 2

2906272

195

PAS-1

2765615

77

PLT-SEC-T3-120-FM

2905228

71

PLT-SEC-T3-120-P

2905234

71

PLT-SEC-T3-230-FM

2905229

71

PLT-SEC-T3-230-P

2905235

71

PLT-SEC-T3-24-FM

2905223

71

PLT-SEC-T3-24-P

2905232

71

PLT-SEC-T3-3S-230-FM

2905230

71

PLT-SEC-T3-3S-230-P

2905236

71

PLT-SEC-T3-60-FM

2905225

71

PLT-SEC-T3-60-P

2905233

71

PLT-SEC-T3-BE

2905557

71

PLT-T3-IT-230-FM

2906450

72

PLT-T3-IT-230-P

2906451

72

PRT-1S-350/20/R

2905977

70

PRT-1S-350/5S

2908551

70

PT 1X2+F-BE

2856126

98

PT 1X2- 5DC-ST

2856016

98

PT 1X2-12AC-ST

2856045

98

PT 1X2-12DC-ST

2856029

98

PT 1X2-24AC-ST

2856058

98

PT 1X2-24DC-ST

2856032

98

PT 1X2-48DC-ST

2803658

98

PT 1X2-BE

2856113

98

PT 2+1-S-48DC-ST

2839648

72

PT 2+1-S-48DC/FM

2817958

72

PT 2-F-ST

2859000

115

PT 2-TELE

2882828

164

PT 2-TELE-ST

2838733

164

PT 2X1+F-BE

2856142

112

PT 2X1- 5DC-ST

2856061

112

PT 2X1-12AC-ST

2856090

113

PT 2X1-12DC-ST

2856074

112

PT 2X1-24AC-ST

2856100

113

PT 2X1-24DC-ST

2856087

112

PT 2X1-BE

2856139

112

PT 2X1-VF-120AC

2859327

114

PT 2X1-VF-120AC-ST

2856799

114

PT 2X1-VF-230AC

2805460

114

PT 2X1-VF-230AC-ST

2921365

114

PT 2X1VA- 60AC-ST

2839172

114

PT 2X1VA-120AC-ST

2839185

114

PT 2X1VA-230AC-ST

2839198

114

PT 2X2+F-BE

2839224

99

PT 2X2- 5DC-ST

2838241

99

PT 2X2-12DC-ST

2838254

99

PT 2X2-24AC-ST

2838283

99

PT 2X2-24DC-ST

2838228

99

PT 2X2-BE

2839208

99

PT 2X2-FF-ST

2800755

161

PT 2X2-HF- 5 DC-ST

2839567

161

PT 2X2-HF-12 DC-ST

2839570

161

PT 2X2-HF-24 DC-ST

2839729

161

PT 2XEX(I)-24DC-ST

2838225

132

PT 2XEX(I)-BE

2839279

132

PT 3-HF-12DC-ST

2858043

145

PT 3-PB-ST

2858030

154

PT 4+F-BE

2839415

116

PT 4- 5DC-ST

2839211

116

PT 4-12DC-ST

2839237

116

PT 4-24AC-ST

2800078

116

PT 4-24DC-ST

2839240

116

PT 4-BE

2839402

115

PT 4-EX(I)-24DC-ST

2839253

134

PT 4-EX(I)-BE

2839486

134

PT 4-F-ST

2858441

115

PT 4X1+F-BE

2839376

113

PT 4X1- 5DC-ST

2838306

113

PT 4X1-12DC-ST

2838319

113

PT 4X1-24AC-ST

2838351

113

PT 4X1-24DC-ST

2838322

113

PT 4X1-48AC-ST

2804856

113

PT 4X1-48DC-ST

2858014

113

PT 4X1-BE

2839363

113

PT 5-HF- 5 DC-ST

2838762

147

PT 5-HF-12 DC-ST

2838775

147

PT 5-HF-24DC-ST

2906002

160

PT 6-FSI/C

3212166

334

PT 6-FSI/C-LED 12

3212169

334

PT 6-FSI/C-LED 24

3212172

334

PT 6-FSI/C-LED 48

3212175

334

PT PE/S+1X2-24-ST

2819008

99

PT PE/S+1X2-BE

2856265

99

PT-BE/FM

2839282

114

PT-IQ-1X2+F-12DC-PT

2801254

97

PT-IQ-1X2+F-12DC-UT

2800975

97

PT-IQ-1X2+F-24DC-PT

2801256

97

PT-IQ-1X2+F-24DC-UT

2800977

97

PT-IQ-1X2+F-48DC-PT

2801258

97

PT-IQ-1X2+F-48DC-UT

2800979

97

PT-IQ-1X2+F-5DC-PT

2801252

97

PT-IQ-1X2+F-5DC-UT

2800792

97

PT-IQ-1X2-12DC-PT

2801253

96

PT-IQ-1X2-12DC-UT

2800793

96

PT-IQ-1X2-24DC-PT

2801255

96

PT-IQ-1X2-24DC-UT

2800976

96

PT-IQ-1X2-48DC-PT

2801257

96

PT-IQ-1X2-48DC-UT

2800978

96

PT-IQ-1X2-5DC-PT

2801251

96

PT-IQ-1X2-5DC-UT

2800791

96

PT-IQ-1X2-EX-24DC-P

2801514

129

PT-IQ-1X2-EX-24DC-UT

2801512

129

PT-IQ-1X2-TELE-P

2800782

163

PT-IQ-1X2-TELE-PT

2801290

163

PT-IQ-1X2-TELE-UT

2800769

163

PT-IQ-2X1+F-24DC-PT

2801248

111

PT-IQ-2X1+F-24DC-UT

2800788

111

PT-IQ-2X1+F-48DC-PT

2801250

111

PT-IQ-2X1+F-48DC-UT

2800790

111

PT-IQ-2X1-24DC-PT

2801247

110

PT-IQ-2X1-24DC-UT

2800787

110

PT-IQ-2X1-48DC-PT

2801249

110

PT-IQ-2X1-48DC-UT

2800789

110

PT-IQ-2X2+F-12DC-PT

2801262

97

PT-IQ-2X2+F-12DC-UT

2800985

97

PT-IQ-2X2+F-24DC-PT

2801264

97

PT-IQ-2X2+F-24DC-UT

2800981

97

PT-IQ-2X2+F-48DC-PT

2801266

97

PT-IQ-2X2+F-48DC-UT

2800987

97

PT-IQ-2X2+F-5DC-PT

2801260

97

PT-IQ-2X2+F-5DC-UT

2800809

97

PT-IQ-2X2-12DC-PT

2801261

97

PT-IQ-2X2-12DC-UT

2800984

97

PT-IQ-2X2-24DC-PT

2801263

97

PT-IQ-2X2-24DC-UT

2800980

97

PT-IQ-2X2-48DC-PT

2801265

97

PT-IQ-2X2-48DC-UT

2800986

97

PT-IQ-2X2-5DC-PT

2801259

97

PT-IQ-2X2-5DC-UT

2800807

97

PT-IQ-2X2-EX-24DC-P

2801515

129

PT-IQ-2X2-EX-24DC-UT

2801513

129

PT-IQ-3-HF+F-12DC-PT

2801289

145

PT-IQ-3-HF+F-12DC-UT

2800995

145

PT-IQ-3-HF-12DC-PT

2801288

153

PT-IQ-3-HF-12DC-UT

2800786

153

PT-IQ-3-PB-PT

2801286

153

PT-IQ-3-PB-UT

2800785

153

PT-IQ-4X1+F-24DC-PT

2801272

111

PT-IQ-4X1+F-24DC-UT

2800983

111

PT-IQ-4X1+F-48DC-PT

2801274

111

PT-IQ-4X1+F-48DC-UT

2801220

111

PT-IQ-4X1-24DC-PT

2801271

111

PT-IQ-4X1-24DC-UT

2800982

111

PT-IQ-4X1-48DC-PT

2801273

111

PT-IQ-4X1-48DC-UT

2801219

111

PT-IQ-5-HF+F-12DC-PT

2801295

147

PT-IQ-5-HF+F-12DC-UT

2800801

147

PT-IQ-5-HF+F-5DC-PT

2801292

147

PT-IQ-5-HF+F-5DC-UT

2800798

147

PT-IQ-5-HF-12DC-PT

2801293

146

PT-IQ-5-HF-12DC-UT

2800799

146

PT-IQ-5-HF-5DC-PT

2801291

146

PT-IQ-5-HF-5DC-UT

2800797

146

PT-IQ-PTB-PT

2801296

96

PT-IQ-PTB-UT

2800768

96

PWT 100-800AC-FM

2800531

40

PWT 35-800AC-FM

2800419

40

PWT CCT-SET

2800532

40

PWT CCT-SET 4

2905613

40

Q

QUINT-BAT/24DC/ 3.4AH

2866349

303

QUINT-BAT/24DC/ 7.2AH

2866352

303

QUINT-BAT/24DC/12AH

2866365

303

QUINT-ORING/24DC/2X10/1X20

2320173

260

QUINT-ORING/24DC/2X20/1X40

2320186

261

QUINT-ORING/24DC/2X40/1X80

2902879

261

QUINT-PS-ADAPTERS7/1

2938196

268

QUINT-PS-ADAPTERS7/2

2938206

268

QUINT-PS/12DC/12DC/8

2905007

251

QUINT-PS/12DC/24DC/ 5

2320131

250

QUINT-PS/1AC/12DC/15

2866718

212

QUINT-PS/1AC/12DC/20

2866721

212

QUINT-PS/1AC/24DC/ 3.5

2866747

210

QUINT-PS/1AC/24DC/ 5/CO

2320908

216

QUINT-PS/1AC/24DC/10/CO

2320911

217

QUINT-PS/1AC/24DC/20/CO

2320898

217

QUINT-PS/1AC/24DC/40

2866789

210

QUINT-PS/1AC/48DC/ 5

2866679

213

QUINT-PS/1AC/48DC/10

2866682

213

QUINT-PS/1AC/48DC/20

2866695

213

QUINT-PS/24DC/12DC/ 8

2320115

249

QUINT-PS/24DC/24DC/ 5

2320034

248

QUINT-PS/24DC/24DC/ 5/CO

2320542

254

QUINT-PS/24DC/24DC/10

2320092

248

Index

Alphabetical

351

PHOENIX CONTACT

phoenixcontact-protection-html.html
background image

Type

Order No. Page

Type

Order No. Page

Type

Order No. Page

Type

Order No. Page

QUINT-PS/24DC/24DC/10/CO

2320555

254

QUINT-PS/24DC/24DC/20

2320102

249

QUINT-PS/24DC/24DC/20/CO

2320568

255

QUINT-PS/24DC/48DC/ 5

2320128

249

QUINT-PS/2AC/1DC/24DC/20

2320830

215

QUINT-PS/3AC/24DC/20/CO

2320924

217

QUINT-PS/3AC/24DC/40

2866802

211

QUINT-PS/3AC/48DC/20

2320827

214

QUINT-PS/48DC/24DC/ 5

2320144

252

QUINT-PS/48DC/48DC/5

2905008

253

QUINT-PS/60-72DC/24DC/10

2905009

253

QUINT-PS/60-72DC/24DC/10/CO

2905011

255

QUINT-PS/96-110DC/24DC/10

2905010

253

QUINT-PS/96-110DC/24DC/10/CO

2905012

255

QUINT-PS/FAN/4

2320076

268

QUINT-UPS/  1AC/  1AC/500VA

2320270

280

QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH

2320254

294

QUINT-UPS/ 24DC/ 24DC/10

2320225

275

QUINT-UPS/ 24DC/ 24DC/10/3.4AH

2320267

294

QUINT-UPS/ 24DC/ 24DC/20

2320238

275

QUINT-UPS/ 24DC/ 24DC/40

2320241

275

QUINT-UPS/ 24DC/12DC/5/24DC/10

2320461

276

QUINT-UPS/24DC/24DC/5

2320212

274

QUINT4-BUFFER/24DC/20

2907913

295

QUINT4-BUFFER/24DC/40

2908283

295

QUINT4-CAP/24DC/10/8KJ

2320571

297

QUINT4-CAP/24DC/5/4KJ

2320539

296

QUINT4-DIODE/12-24DC/2X20/1X40

2907719

264

QUINT4-DIODE/48DC/2X20/1X40

2907720

265

QUINT4-PS/1AC/24DC/10

2904601

206

QUINT4-PS/1AC/24DC/20

2904602

207

QUINT4-PS/1AC/24DC/5

2904600

206

QUINT4-PS/3AC/24DC/10

2904621

208

QUINT4-PS/3AC/24DC/20

2904622

209

QUINT4-PS/3AC/24DC/5

2904620

208

QUINT4-S-ORING/12-24DC/1X40

2907752

262

QUINT4-S-ORING/12-24DC/1X40/+

2907753

263

QUINT4-UPS/1AC/1AC/1KVA

2320283

281

R

RAD-ADP-N/M-SMA/F

2917036

176

RAD-PIG-EF316-MCX-N

2867681

176

RAD-PIG-EF316-N-SMA

2867694

178

S

S-PT-1X2-24DC

2880668

101

S-PT-1X2-24DC-1/2"

2882569

101

S-PT-1X2-24DC-3/4"

2882598

101

S-PT-2XEX-24DC

2800040

131

S-PT-2XEX-24DC-1/2"

2800041

131

S-PT-2XEX-48DC

2800038

131

S-PT-2XEX-48DC-1/2"

2800039

131

S-PT-4-EX-24DC

2800036

118

S-PT-4-EX-24DC-1/2"

2800037

118

S-PT-EX(I)-24DC

2880671

130

S-PT-EX(I)-24DC-1/2"

2882572

130

S-PT-EX(I)-24DC-3/4"

2882585

130

S-PT-EX-24DC

2800034

130

S-PT-EX-24DC-1/2"

2800035

130

S-PT-EX-48DC

2800053

130

S-PT-EX-48DC-1/2"

2800054

130

SFP 1-10/120AC

2920670

185

SFP 1-15/120AC

2920683

185

SFP 1-20/120AC

2856702

184

SFP 1-20/230AC

2859987

184

SFP 1-5/120AC

2920667

185

SPRING-LOCK

0713009

324

SSA 3-6

2839295

197

SSA 5-10

2839512

197

ST 4-FSI/C

3036372

334

ST 4-FSI/C-LED 12

3036495

334

ST 4-FSI/C-LED 24

3036505

334

STEP-BAT/LIPO/18.5DC/1.4AH

2320364

298

STEP-DIODE/5-24DC/2X5/1X10

2868606

267

STEP-PS/ 1AC/ 5DC/2

2320513

242

STEP-PS/ 1AC/ 5DC/6.5

2868541

243

STEP-PS/ 1AC/12DC/1

2868538

244

STEP-PS/ 1AC/12DC/1.5

2868567

245

STEP-PS/ 1AC/12DC/1.5/FL

2868554

244

STEP-PS/ 1AC/12DC/3

2868570

245

STEP-PS/ 1AC/12DC/5

2868583

245

STEP-PS/ 1AC/15DC/4

2868619

243

STEP-PS/ 1AC/24DC/0.5

2868596

238

STEP-PS/ 1AC/24DC/0.75

2868635

239

STEP-PS/ 1AC/24DC/0.75/FL

2868622

239

STEP-PS/ 1AC/24DC/1.75

2868648

240

STEP-PS/ 1AC/24DC/2.5

2868651

240

STEP-PS/ 1AC/24DC/3.8/C2LPS

2868677

241

STEP-PS/ 1AC/24DC/4.2

2868664

241

STEP-PS/ 1AC/48DC/2

2868680

243

STEP-PS/277AC/24DC/3.5

2904945

241

STEP-PS/48AC/24DC/0.5

2868716

239

STEP-UPS/12DC/12DC/4

2868693

298

STEP-UPS/24DC/24DC/3

2868703

298

SVP 2E- 48AC

2788919

168

SVP 2E-110AC

2765534

168

SVP 3E-110AC

2765521

168

SZS 0,6X3,5

1205053

326

T

TAE-TRAB FM-NFN-AP

2749628

165

TCP  0,1A

0712107

335

TCP  0,25A

0712123

335

TCP  0,5A

0712152

335

TCP  1A

0712194

335

TCP  2A

0712217

335

TCP  3A

0712233

335

TCP  4A

0712259

335

TCP  5/DC32V

0700005

334

TCP  6A

0712275

335

TCP  7,5/DC32V

0700007

334

TCP  8A

0712291

335

TCP 10/DC32V

0700010

334

TCP 10A

0712314

335

TCP 15/DC32V

0700015

334

TCP 20/DC32V

0700020

334

TCP 25/DC32V

0700025

334

TCP 30/DC32V

0700030

334

TCP 40/DC32V

0700040

334

TMC 1 F1 100  0,2A

0914015

333

TMCP CONNECT LR

0916592

324

TMCP SB

0916602

324

TMCP SOCKET M

0916589

324

TRIO-PS-2G/1AC/12DC/10

2903158

225

TRIO-PS-2G/1AC/12DC/5/C2LPS

2903157

224

TRIO-PS-2G/1AC/24DC/10

2903149

220

TRIO-PS-2G/1AC/24DC/10/B+D

2903145

221

TRIO-PS-2G/1AC/24DC/20

2903151

221

TRIO-PS-2G/1AC/24DC/3/C2LPS

2903147

218

TRIO-PS-2G/1AC/24DC/5

2903148

219

TRIO-PS-2G/1AC/24DC/5/B+D

2903144

219

TRIO-PS-2G/1AC/48DC/10

2903160

225

TRIO-PS-2G/1AC/48DC/5

2903159

225

TRIO-PS-2G/3AC/24DC/10

2903154

223

TRIO-PS-2G/3AC/24DC/20

2903155

223

TRIO-PS-2G/3AC/24DC/40

2903156

223

TRIO-PS-2G/3AC/24DC/5

2903153

222

TRIO-PS/600DC/24DC/20

2866530

215

TRIO-UPS-2G/1AC/1AC/120V/750VA

2905908

282

TRIO-UPS-2G/1AC/1AC/230V/750VA

2905909

282

TRIO-UPS/1AC/24DC/ 5

2866611

300

TRIO2-DIODE/12-24DC/2X10/1X20

2907380

266

TRIO2-DIODE/12-24DC/2X20/1X40

2907379

267

TT-D-STTCO-BK

2858894

186

TT-ST-M-SFP-24AC

2858946

186

TTC-3-1X2-24DC-PT

2907325

95

TTC-3-2X1-24DC-PT

2907326

109

TTC-3-LCP

2908843

95

TTC-6-1X2-24DC-PT

2906804

94

TTC-6-1X2-24DC-UT

2906798

94

TTC-6-1X2-F-M-24DC-PT-I

2906772

94

TTC-6-1X2-F-M-24DC-UT-I

2906764

94

TTC-6-1X2-M-24DC-PT-I

2906726

94

TTC-6-1X2-M-24DC-UT-I

2906713

94

TTC-6-1X2-M-EX-24DC-UT-I

2906820

128

TTC-6-2-24DC-PT

2906806

120

TTC-6-2-24DC-UT

2906800

120

TTC-6-2-HC-24DC-PT-I

2908439

107

TTC-6-2-HC-24DC-UT-I

2908438

107

TTC-6-2-HC-M-24DC-PT-I

2906731

107

TTC-6-2-HC-M-24DC-UT-I

2906719

107

TTC-6-2X1-24DC-PT

2906805

108

TTC-6-2X1-24DC-UT

2906799

108

TTC-6-2X1-F-M-24DC-PT-I

2906776

108

TTC-6-2X1-F-M-24DC-UT-I

2906767

108

TTC-6-2X1-M-24DC-PT-I

2906729

108

TTC-6-2X1-M-24DC-UT-I

2906716

108

TTC-6-2X1-M-EX-24DC-UT-I

2906821

133

TTC-6-2XTVSD-24DC-PT

2906808

124

TTC-6-3-HF-F-M-12DC-PT-I

2906778

151

TTC-6-3-HF-F-M-12DC-UT-I

2906769

151

TTC-6-3-HF-F-M-24DC-PT-I

2906779

151

TTC-6-3-HF-F-M-24DC-UT-I

2906770

151

TTC-6-3-HF-F-M-EX-12DC-UT-I

2906822

156

TTC-6-3-HF-F-M-EX-24DC-UT-I

2906823

156

TTC-6-3-HF-M-12DC-PT-I

2906732

150

TTC-6-3-HF-M-12DC-UT-I

2906721

150

TTC-6-FMRS-PT

2907811

103

TTC-6-FMRS-UT

2907810

103

TTC-6-GDT-C-110AC-PT-I

2906861

127

TTC-6-GDT-C-110AC-UT-I

2906844

127

TTC-6-GDT-C-24AC-PT-I

2906860

127

TTC-6-GDT-C-24AC-UT-I

2906842

127

TTC-6-GDT-D-24AC-PT-I

2906862

127

TTC-6-GDT-D-24AC-UT-I

2906845

127

TTC-6-GDT-D-60AC-PT-I

2906863

127

TTC-6-GDT-D-60AC-UT-I

2906846

127

TTC-6-LCP

2908729

124

TTC-6-MOV-C-120AC-PT-I

2906858

126

TTC-6-MOV-C-120AC-UT-I

2906840

126

TTC-6-MOV-C-24DC-PT-I

2906854

126

TTC-6-MOV-C-24DC-UT-I

2906837

126

TTC-6-MOV-C-48DC-PT-I

2906855

126

TTC-6-MOV-C-48DC-UT-I

2906838

126

TTC-6-MOV-C-60DC-PT-I

2906857

126

TTC-6-MOV-C-60DC-UT-I

2906839

126

TTC-6-MOV-D-24DC-PT-I

2906859

126

TTC-6-MOV-D-24DC-UT-I

2906841

126

TTC-6-TVSD-C-12DC-PT-I

2906847

124

TTC-6-TVSD-C-12DC-UT-I

2906829

124

TTC-6-TVSD-C-24DC-PT-I

2906848

124

TTC-6-TVSD-C-24DC-UT-I

2906831

124

TTC-6-TVSD-C-48DC-PT-I

2906849

124

TTC-6-TVSD-C-48DC-UT-I

2906832

124

TTC-6-TVSD-C-60DC-PT-I

2906850

124

TTC-6-TVSD-C-60DC-UT-I

2906833

124

TTC-6-TVSD-D-24DC-PT-I

2906851

125

TTC-6-TVSD-D-24DC-UT-I

2906834

125

TTC-6-TVSD-D-48DC-PT-I

2906852

125

TTC-6-TVSD-D-48DC-UT-I

2906835

125

TTC-6-TVSD-D-60DC-PT-I

2906853

125

TTC-6-TVSD-D-60DC-UT-I

2906836

125

TTC-6P-1X2-12DC-PT-I

2908193

92

TTC-6P-1X2-12DC-UT-I

2908192

92

TTC-6P-1X2-24DC-PT-I

2906815

92

TTC-6P-1X2-24DC-UT-I

2906809

92

TTC-6P-1X2-48DC-PT-I

2908195

92

TTC-6P-1X2-48DC-UT-I

2908194

92

TTC-6P-1X2-F-12DC-PT-I

2908198

93

TTC-6P-1X2-F-12DC-UT-I

2908196

93

TTC-6P-1X2-F-48DC-PT-I

2908200

93

TTC-6P-1X2-F-48DC-UT-I

2908199

93

TTC-6P-1X2-F-M-24DC-PT-I

2906790

93

TTC-6P-1X2-F-M-24DC-UT-I

2906781

93

TTC-6P-1X2-M-24DC-PT-I

2906750

92

TTC-6P-1X2-M-24DC-UT-I

2906738

92

TTC-6P-1X2-M-EX-24DC-UT-I

2906824

128

TTC-6P-2-HC-24DC-PT-I

2906817

106

TTC-6P-2-HC-24DC-UT-I

2906811

106

TTC-6P-2-HC-M-24DC-PT-I

2906755

106

TTC-6P-2-HC-M-24DC-UT-I

2906743

106

TTC-6P-2X1-12DC-PT-I

2908202

104

TTC-6P-2X1-12DC-UT-I

2908201

104

TTC-6P-2X1-24DC-PT-I

2906816

104

TTC-6P-2X1-24DC-UT-I

2906810

104

TTC-6P-2X1-48DC-PT-I

2908204

104

TTC-6P-2X1-48DC-UT-I

2908203

104

TTC-6P-2X1-F-12DC-PT-I

2908206

105

TTC-6P-2X1-F-12DC-UT-I

2908205

105

TTC-6P-2X1-F-48DC-PT-I

2908209

105

TTC-6P-2X1-F-48DC-UT-I

2908208

105

TTC-6P-2X1-F-M-24DC-PT-I

2906794

105

TTC-6P-2X1-F-M-24DC-UT-I

2906784

105

TTC-6P-2X1-M-24DC-PT-I

2906753

104

TTC-6P-2X1-M-24DC-UT-I

2906741

104

TTC-6P-2X1-M-EX-24DC-UT-I

2906825

133

TTC-6P-3-HF-F-M-12DC-PT-I

2906796

151

TTC-6P-3-HF-F-M-12DC-UT-I

2906786

151

TTC-6P-3-HF-F-M-24DC-PT-I

2906797

151

TTC-6P-3-HF-F-M-24DC-UT-I

2906787

151

TTC-6P-3-HF-F-M-EX-12DC-UT-I

2906826

157

TTC-6P-3-HF-F-M-EX-24DC-UT-I

2906828

157

TTC-6P-3-HF-M-12DC-PT-I

2906756

151

TTC-6P-3-HF-M-12DC-UT-I

2906744

151

U

UC-TM  6 GN

0818360

197

UK  6-FSI/C

3118203

334

UK  6-FSI/C-LED12

3001925

334

UK  6-FSI/C-LED24

3001938

334

UNO-DIODE/5-24DC/2X10/1X20

2905489

267

UNO-PS/1AC/ 5DC/ 25W

2904374

230

UNO-PS/1AC/ 5DC/ 40W

2904375

230

UNO-PS/1AC/12DC/ 30W

2902998

229

UNO-PS/1AC/12DC/ 55W

2902999

229

UNO-PS/1AC/12DC/100W

2902997

229

UNO-PS/1AC/15DC/ 55W

2903001

231

UNO-PS/1AC/15DC/100W

2903002

231

UNO-PS/1AC/15DC/30W

2903000

231

UNO-PS/1AC/24DC/ 30W

2902991

226

UNO-PS/1AC/24DC/ 60W

2902992

226

UNO-PS/1AC/24DC/100W

2902993

227

UNO-PS/1AC/24DC/150W

2904376

227

UNO-PS/1AC/24DC/240W

2904372

227

UNO-PS/1AC/24DC/90W/C2LPS

2902994

228

UNO-PS/1AC/48DC/ 60W

2902995

232

UNO-PS/1AC/48DC/100W

2902996

232

UNO-PS/2AC/24DC/90W/C2LPS

2904371

228

UNO-PS/350-900DC/24DC/60W

2906300

233

UNO-UPS/24DC/24DC/60W

2905907

299

UPS-BAT/LI-ION/24DC/120WH

2320351

285

UPS-BAT/LI-ION/24DC/924WH

2908232

285

UPS-BAT/VRLA-WTR/24DC/13AH

2320416

288

UPS-BAT/VRLA-WTR/24DC/26AH

2320429

288

UPS-BAT/VRLA/24DC/1.3AH

2320296

286

UPS-BAT/VRLA/24DC/12AH

2320322

287

UPS-BAT/VRLA/24DC/3.4AH

2320306

286

UPS-BAT/VRLA/24DC/38AH

2320335

287

UPS-BAT/VRLA/24DC/7.2AH

2320319

287

UPS-CAP/24DC/10A/10KJ

2320377

284

UPS-CAP/24DC/20A/20KJ

2320380

284

UPS-CONF

2320403

290

UT 6-TMC M 0,5A

0916603

332

UT 6-TMC M 10A

0916610

332

UT 6-TMC M 12A

0916611

332

UT 6-TMC M 15A

0916612

332

UT 6-TMC M 16A

0916613

332

UT 6-TMC M 1A

0916604

332

UT 6-TMC M 2A

0916605

332

UT 6-TMC M 4A

0916606

332

UT 6-TMC M 5A

0916607

332

UT 6-TMC M 6A

0916608

332

UT 6-TMC M 8A

0916609

332

UWA 130

2901664

269

UWA 182/52

2938235

269

Index

Alphabetical

352

PHOENIX CONTACT

phoenixcontact-protection-html.html
background image

Type

Order No. Page

Type

Order No. Page

353

PHOENIX CONTACT

Index

Alphabetical

V

VAL-CP-350-ST-GY

2882718

66

VAL-CP-MCB-1S-350/40/FM

2882763

66

VAL-CP-MCB-3C-350/40/FM

2882776

66

VAL-CP-MCB-3S-350/40/FM

2882750

66

VAL-CP-MOSO 60-3C-FM

2804416

68

VAL-CP-MOSO 60-3S-FM

2804403

68

VAL-CP-N/PE-350-ST-GY

2882734

66

VAL-CP-RCD-3S/40/0.03

2882802

67

VAL-CP-RCD-3S/40/0.3/SEL

2808001

67

VAL-MB-T1/T2 1000DC-PV/2+V

2905639

41

VAL-MB-T1/T2 1000DC-PV/2+V-FM

2905638

41

VAL-MB-T1/T2 1500DC-PV/2+V

2905641

41

VAL-MB-T1/T2 1500DC-PV/2+V-FM

2905640

41

VAL-MB-T1/T2 600DC-PV/2+V

2906293

41

VAL-MB-T1/T2 600DC-PV/2+V-FM

2906292

41

VAL-MB-T2 1500DC-PV/2+V

2905647

64

VAL-MB-T2 1500DC-PV/2+V-FM

2905646

64

VAL-MS  60 ST

2807573

58

VAL-MS 1000DC-PV-ST

2800624

65

VAL-MS 1000DC-PV/2+V

2800628

65

VAL-MS 1000DC-PV/2+V-FM

2800627

65

VAL-MS 120 ST

2807586

58

VAL-MS 230 IT ST

2807599

59

VAL-MS 230 ST

2798844

59

VAL-MS 230-UD-ST

2858962

59

VAL-MS 230/1+1

2804429

53

VAL-MS 230/1+1-FM

2804432

53

VAL-MS 230/3+1

2838209

52

VAL-MS 230/3+1 FM

2838199

52

VAL-MS 320 ST

2838843

60

VAL-MS 320-UD ST

2858315

61

VAL-MS 320/1+1

2804380

53

VAL-MS 320/1+1-FM

2804393

53

VAL-MS 320/3+0

2920230

53

VAL-MS 320/3+0-FM

2920243

53

VAL-MS 320/3+1

2859178

52

VAL-MS 320/3+1/FM

2859181

52

VAL-MS 320/3+1/FM-UD

2856689

52

VAL-MS 350 VF ST

2856595

63

VAL-MS 350 VF/3+1

2858755

54

VAL-MS 350 VF/FM

2856579

54

VAL-MS 350VF

2856582

54

VAL-MS 350VF/3+1-FM

2858632

54

VAL-MS 4+V/BE/FM

2908725

65

VAL-MS 400 ST

2816399

61

VAL-MS 500 ST

2807609

61

VAL-MS 580-ST

2920434

62

VAL-MS 60

2868020

55

VAL-MS 60/FM

2868033

55

VAL-MS 600DC-PV-ST

2800623

65

VAL-MS 600DC-PV/2+V

2800642

65

VAL-MS 600DC-PV/2+V-FM

2800641

65

VAL-MS 75 VF ST

2805318

62

VAL-MS 750/30-ST

2920256

56

VAL-MS 750/30/3+0

2920269

56

VAL-MS 750/30/3+0-FM

2920272

56

VAL-MS 800/30 VF/FM

2805402

56

VAL-MS BE

2817741

58

VAL-MS BE/1+1/1U/FM

2909628

39

VAL-MS BE/2+0/1U/FM

2907037

58

VAL-MS BE/FM

2817738

58

VAL-MS-CN 1000DC-PV/4+V-FM

2907820

65

VAL-MS-T1/T2 1000DC-PV-ST

2801162

41

VAL-MS-T1/T2 1000DC-PV/2+V

2801160

41

VAL-MS-T1/T2 1000DC-PV/2+V-FM

2801161

41

VAL-MS-T1/T2 175/12.5 ST

2800676

37

VAL-MS-T1/T2 175/12.5/1+1-FM

2800674

37

VAL-MS-T1/T2 175/12.5/3+0-FM

2800672

37

VAL-MS-T1/T2 335/12.5 ST

2800190

36

VAL-MS-T1/T2 335/12.5/1+0

2801041

37

VAL-MS-T1/T2 335/12.5/1+0-FM

2801042

37

VAL-MS-T1/T2 335/12.5/1+1

2800187

37

VAL-MS-T1/T2 335/12.5/1+1-FM

2800186

37

VAL-MS-T1/T2 335/12.5/3+0

2800189

37

VAL-MS-T1/T2 335/12.5/3+0-FM

2800188

37

VAL-MS-T1/T2 335/12.5/3+1

2800184

36

VAL-MS-T1/T2 335/12.5/3+1-FM

2800183

36

VAL-MS-T1/T2 335/12.5/4+0

2800645

36

VAL-MS-T1/T2 335/12.5/4+0-FM

2800644

36

VAL-MS-T1/T2 48/12.5 ST

2801242

38

VAL-MS-T1/T2 48/12.5/1+0

2801241

38

VAL-MS-T1/T2 48/12.5/1+0-FM

2801240

38

VAL-MS-T1/T2 48/12.5/1+1/1U/FM

2909629

39

VAL-MS-T1/T2 48/12.5/1+1V

2801532

38

VAL-MS-T1/T2 48/12.5/1+1V-FM

2801533

38

VAL-MS-T1/T2 48/12.5/O

2906281

39

VAL-MS-T1/T2 48/12.5/O-FM

2906282

39

VAL-MS-T1/T2 600DC-PV-ST

2801165

41

VAL-MS-T1/T2 600DC-PV/2+V

2801163

41

VAL-MS-T1/T2 600DC-PV/2+V-FM

2801164

41

VAL-MS-T1/T2 BE/O

2905650

39

VAL-MS-T1/T2 BE/O-FM

2905652

39

VAL-MS/1+1-BE

2920528

58

VAL-MS/1+1-BE/FM

2920531

58

VAL-MS/2+0-BE

2804584

58

VAL-MS/2+0-BE/FM

2805321

58

VAL-MS/3+0-BE

2881816

59

VAL-MS/3+0-BE/FM

2881803

59

VAL-MS/3+1-BE

2838885

58

VAL-MS/3+1-BE/FM

2838898

58

VAL-MS/3+1-BE/FM-UD

2858674

59

VAL-MS/4+0-BE/FM RN.

2906484

59

VAL-SEC-T2-120DC-P

2907878

50

VAL-SEC-T2-175-P

2905355

48

VAL-SEC-T2-1S-175-FM

2905348

49

VAL-SEC-T2-1S-350

2905341

47

VAL-SEC-T2-1S-350-FM

2905333

47

VAL-SEC-T2-1S-350VF-FM

2909592

47

VAL-SEC-T2-2+0-120DC-FM

2907874

50

VAL-SEC-T2-2+0-220DC-FM

2907875

51

VAL-SEC-T2-2+0-380DC-FM

2907876

51

VAL-SEC-T2-2+0-48DC-FM

2907865

50

VAL-SEC-T2-220DC-P

2907879

51

VAL-SEC-T2-2C-175-FM

2905350

49

VAL-SEC-T2-2C-350

2905342

47

VAL-SEC-T2-2C-350-FM

2905337

47

VAL-SEC-T2-2S-175-FM

2905351

49

VAL-SEC-T2-2S-350

2905343

47

VAL-SEC-T2-2S-350-FM

2905338

47

VAL-SEC-T2-350-P

2905346

42

VAL-SEC-T2-350VF-P

2909596

46

VAL-SEC-T2-380DC-P

2907880

51

VAL-SEC-T2-3C-175-FM

2905353

48

VAL-SEC-T2-3C-350

2905344

46

VAL-SEC-T2-3C-350-FM

2905339

46

VAL-SEC-T2-3C-350VF-FM

2909591

46

VAL-SEC-T2-3C-440-FM

2909968

45

VAL-SEC-T2-3S-175-FM

2905354

48

VAL-SEC-T2-3S-350

2905345

46

VAL-SEC-T2-3S-350-FM

2905340

46

VAL-SEC-T2-3S-350/40

2909637

45

VAL-SEC-T2-3S-350/40-FM

2909635

45

VAL-SEC-T2-3S-350VF-FM

2909590

46

VAL-SEC-T2-440-P

2909969

45

VAL-SEC-T2-48DC-P

2907877

50

VAL-SEC-T2-N/PE-175-P

2905356

48

VAL-SEC-T2-N/PE-264/40-P

2909636

45

VAL-SEC-T2-N/PE-350-P

2905347

46

VIP-2/SC/PDM-2/16

2315256

268

VIP-2/SC/PDM-2/24

2315269

268

VIP-2/SC/PDM-2/32

2315272

268

VIP-2/SC/PDM-2/48

2903717

268

VIP-CAB-FLK16/FR/FR/0,14/0,5M

2900154

100

VIP-CAB-FLK16/FR/FR/0,14/1,0M

2900155

100

VIP-CAB-FLK16/FR/FR/0,14/2,0M

2900156

100

Z

ZB 12:UNPRINTED

0812120

197

ZBN 18 CUS

0825059

197

phoenixcontact-protection-html.html
background image
phoenixcontact-protection-html.html
background image

For up-to-date modifications or supplements
to the catalog contents, please visit:

phoenixcontact.net/webcode/

#0132

 

BuchHK4.book  Seite 1  Mittwoch, 1. März 2017  2:46 14

Textfarbe Schmuck 45,0° 120,0 LPI 

phoenixcontact-protection-html.html
background image

Cyprus

Uruguay

Slovenia

Greece

Macedonia

Montenegro

Kosovo

Bosnia and

Herzegovina Serbia

Bulgaria

Georgia

Azerbaijan

Lebanon

Saudi Arabia

Oman

Bahrain

Qatar

Bangladesh

Honduras

Ecuador

Venezuela

Peru

Bolivia

Paraguay

Nicaragua

Costa Rica

Panama

Guatemala

Iceland

Sri Lanka

Pakistan

Kuwait

Iran

Iraq

Jordan

Egypt

Tunisia

Morocco

Algeria

Kenya

Uganda

Tanzania

Namibia

Botswana

Zimbabwe

Mozambique

Zambia

Nigeria

Ghana

Armenia

Portugal

Spain

France

Switzerland

Austria

Italy

Netherlands

Belgium

Luxembourg

Poland

Czech Republic

Slovakia
Hungary

Croatia

Romania

United Kingdom

Ireland

Turkey

Israel

UAE

Vietnam

Philippines

Taiwan

Thailand

Singapore

New Zealand

Chile

Argentina

Colombia

Canada

Russia

Finland

Estonia

Latvia

Lithuania

Belarus

Ukraine

Sweden

Norway

Denmark

Kazakhstan

South Korea

Japan

Mexico

Brazil

Australia

Indonesia

Malaysia

India

South Africa

Myanmar

USA

China

Blomberg, Germany