Description
HPV10001.072T CAMTEC Power Supply 115 / 230VAC – 1000W, 1-phase AC / DC high voltage RoHS
- DIN-Rail Power Supply 1phase fix output TS35mm DIN EN 50022
- Temperature Control
- Clean C/V chart without foldback, ideal for dc drives
HPV10001
Model | HPV10001 | |||
Power | 1008W | |||
Nominal AC Input | 115/230Vac | |||
Input Range AC | 90..115Vac/186..265Vac | |||
Input Range DC | 250… 375Vdc | |||
Input Frequency | 47… 63Hz | |||
Hold-Up Time | 30ms | |||
Inrush Current Protection | NTC < 84A | |||
Autostart | Soft start 100ms | |||
Output Voltage | 72V | 110V | 150V | 240V |
Adjust Range Vout | 58… 86V | 86… 132V | 132… 180V | 180… 240V |
Ripple & Noise mVpp | 200mV | 250mV | 250mV | 300mV |
Nominal Output Current | 13,9A | 9,1A | 6,7A | 4,6A |
Power Boost <=60°C/60s | 15,3A | 10A | 7,4A | 5A |
Stability at Load Switch | ±0,5% | |||
Transient Time | < 1ms | |||
Efficiency | 0,93 | |||
Basic load | Idling-proof | |||
Short Circuit Protection | Continuous | |||
Ambient Operation Temperature | -20°C… +70°C | |||
Cooling | Natural convection + controlled fan from Papst | |||
Temperature Monitoring | Yes | |||
Dimensions (WxHxD) | 200x156x114,5mm | |||
IP-Range | IP20 | |||
Safety Norms | CSA UL CE according to IEC60950-1 | |||
Safety IEC | EN60950-1 EN50178 EN60204-1 | |||
Safety Class 1(A) | VDE0100 VDE0805 | |||
Input to Output Isolation | 3000Vac | |||
Climatic Class, Humidity | 3k3, 95% non condensing | |||
EMI | EN55022B | |||
EMS | EN61000-6-2,3 | |||
MTBF IEC61709 | 500000h | |||
Power Good Relay | Yes, Option | |||
Ordering options | Protective coating, Popwer Good Relais (PG) | |||
Options | See datasheet |